MONTHYEARML11222A1232011-07-25025 July 2011 License Amendment Request 244: Proposed Revision to Radiological Accident Analysis and Control Room Envelope Habitability Technical Specifications Project stage: Request ML11252A5212011-08-30030 August 2011 License Amendment Request 244: Proposed Revision to Radiological Accident Analysis and Control Room Envelope Habitability Technical Specifications Project stage: Request ML11252A6532011-08-30030 August 2011 License Amendment Request 244, Marked-Up Operating License and Technical Specifications Pages, Attachment 2 Project stage: Request ML11252A6542011-08-30030 August 2011 License Amendment Request 244, Marked-Up Operating Technical Specifications Bases Pages, Attachment 3 Project stage: Request ML11252A6562011-08-30030 August 2011 License Amendment Request 244, Radiological Accident Analysis and Discussion of Associated Technical Specification Changes, Attachment 4 Project stage: Request ML11252A6572011-08-30030 August 2011 License Amendment Request 244, Evaluation of New Proposed Manual Actions, Attachment 5 Project stage: Request ML11252A6582011-08-30030 August 2011 License Amendment Request 244, Data Files, Kewaunee Power Station Meterological Data 2002-2006 X/Q Calculation Support, Enclosure 1 Project stage: Request ML11252A6512011-08-30030 August 2011 License Amendment Request 244, Discussion of Change, Safety Evaluation, Significant Hazards Determination and Environmental Considerations, Attachment 1 Project stage: Request ML11290A1482011-10-17017 October 2011 NRR E-mail Capture - ME7110 - Chi-over-Q Amendment Application - Non-acceptance with Opportunity to Supplement Project stage: Other ML11298A2652011-10-25025 October 2011 NRR E-mail Capture - FW: ME7110 - Kewaunee Chi-over-Q - Acceptance Review RAL Items - Conference Calls of October 20, 25, 2011 Project stage: Acceptance Review ML11304A1462011-10-27027 October 2011 NRR E-mail Capture - FW: ME7110 - Kewaunee Chi-over-Q - Acceptance Review RAL Items - Conference Calls of October 20, 25, 26, 2011 Project stage: Acceptance Review ML11318A2052011-11-0808 November 2011 Response to Request for Additional Information: License Amendment Request 244, Proposed Revision to Radiological Accident Analysis and Control Room Envelope Habitability Technical Specifications Project stage: Response to RAI ML11325A0782011-11-18018 November 2011 NRR E-mail Capture - ME7110 - Kewaunee - LIC-109 Acceptance Review Results for Chi-over-Q License Amendment Request Project stage: Acceptance Review ML11339A0012011-12-0101 December 2011 NRR E-mail Capture - ME7110 Kewaunee Amendment Request Re_ Chi-over-Q - Eicb Request for Additional Information (RAI) Project stage: RAI ML12023A0472012-01-0909 January 2012 NRR E-mail Capture - ME7110 Kewaunee Amendment Request Re_ Chi-over-Q - Ahpb Request for Additional Information (RAI) Project stage: RAI ML12023A0572012-01-13013 January 2012 NRR E-mail Capture - ME7110 Kewaunee Amendment Request Re_ Chi-over-Q - Ahpb Request for Additional Information (RAI) - Firm RAI Items Project stage: RAI ML12031A1382012-01-25025 January 2012 Response to Request for Additional Information on License Amendment Request 244, Proposed Revision to Radiological Accident Analysis and Control Room Envelope Habitability Technical Specifications Project stage: Response to RAI ML12033A0102012-01-30030 January 2012 NRR E-mail Capture - ME7110 Kewaunee Amendment Request Chi-over-Q - Rsxb Request for Additional Information (RAI) Project stage: RAI ML12068A1422012-02-27027 February 2012 Response to Request for Additional Information: License Amendment Request 244, Proposed Revision to Radiological Accident Analysis and Control Room Envelope Habitability Technical Specifications Project stage: Response to RAI ML12066A0082012-03-0202 March 2012 NRR E-mail Capture - ME7110 Kewaunee Amendment Request- Chi-over-Q - Aadb Request for Additional Project stage: Other ML12068A4202012-03-0606 March 2012 E-mail Capture - ME7110 Record of Clarification Conference Call for ME7110 Kewaunee Amendment Request Re_ Chi-over-Q - Aadb Request for Additional Information (RAI) Project stage: RAI ML12080A2232012-03-12012 March 2012 Response to Request for Additional Information: License Amendment Request 244. Proposed Revision to Radiological Accident Analysis and Control Room Envelope Habitability Technical Specifications Project stage: Response to RAI ML12107A1442012-04-13013 April 2012 NRR E-mail Capture - ME7110 Kewaunee - Request for Additional Information (RAI) Aadb and Scvb 2012-04-12 Project stage: RAI ML12124A2832012-04-30030 April 2012 Response to Request for Additional Information: License Amendment Request 244, Proposed Revision to Radiological Accident Analysis and Control Room Envelope Habitability Technical Specifications Project stage: Response to RAI ML12138A0072012-05-15015 May 2012 NRR E-mail Capture - ME7110 Scvb Draft RAI Set Adoption of TSTF-51 & TSTF- 448, as Part of Chi-over-Q Action Project stage: Draft RAI ML12137A0032012-05-15015 May 2012 NRR E-mail Capture - ME7110 Agenda for Draft RAI Clarification Call Re Wednesday 3-4 PM ET - Eicb Input Project stage: Draft RAI ML12164A3742012-06-0606 June 2012 Response to Request for Additional Information: License Amendment Request 244, Proposed Revision to Radiological Accident Analysis and Control Room Envelope Habitability Technical Specifications Project stage: Response to RAI ML12166A0062012-06-13013 June 2012 NRR E-mail Capture - ME7110 - Kewaunee - Chi-Over-Q - Record of Conference Call - Wednesday, June 13, 2012 3:00 PM Project stage: Other ML12193A6832012-06-19019 June 2012 NRR E-mail Capture - ME7110- Kewaunee LAR 244: Executive Summary of LRA Emergent Issue - Further Information - Generic Implications for Otherv Plants Project stage: Approval ML12193A6842012-07-11011 July 2012 NRR E-mail Capture - Record of ME7110 - Kewaunee - Chi-Over-Q - Progress Review (Dated Wed 7/11/2012 3:00 PM - 4:00 PM from Outlook Invitation) Project stage: Other ML12219A2222012-08-0303 August 2012 Response to Request for Additional Information: License Amendment Request 244, Proposed Revision to Radiological Accident Analysis and Control Room Envelope Habitability Technical Specifications Project stage: Response to RAI ML12226A5062012-08-0909 August 2012 Response to Request for Additional Information: License Amendment Request 244. Proposed Revision to Radiological Accident Analysis and Control Room Envelope Habitability Technical Specifications Project stage: Response to RAI ML12236A2062012-08-22022 August 2012 NRR E-mail Capture - FW: ME7110- Kewaunee LAR 244: Executive Summary of LRA Emergent Issue - Further Information - Generic Implications for Other Plants Project stage: Approval ML12248A1492012-08-29029 August 2012 Submittal of Revision to Locked Rotor Radiological Accident Analysis: License Amendment Request 244, Proposed Revision to Radiological Accident Analysis and Control Room Envelope Habitability Technical Specifications Project stage: Request ML12285A1572012-10-10010 October 2012 NRR E-mail Capture - ME7110 - Kewaunee - Chi-over-Q - Request for Additional Information (RAI) Project stage: RAI ML13058A0722013-02-28028 February 2013 Withdrawal of an Amendment Request Project stage: Withdrawal 2012-03-12
[Table View] |
Text
1 NRR-PMDAPEm Resource From:
Feintuch, Karl Sent:
Wednesday, June 13, 2012 6:32 PM To:
Feintuch, Karl
Subject:
ME7110 - Kewaunee - Chi-Over-Q - Record of Conference Call - Wednesday, June 13, 2012 3:00 PM
Original Appointment-----
From: Feintuch, Karl Sent: Wednesday, June 13, 2012 6:17 PM To: Blumberg, Mark; Brown, Leta; Torres, Roberto; Walker, Harold; Alvarado, Rossnyev; Hamm, Matthew; Sun, Summer; Guzzetta, Ashley; Lapinsky, George; ONeal, Daniel Cc: Frankl, Istvan; Schwarz, Sherry; Cohen, Shari
Subject:
ME7110 - Kewaunee - Chi-Over-Q - progress review When: Wednesday, June 13, 2012 3:00 PM-4:00 PM (GMT-05:00) Eastern Time (US & Canada).
Where: HQ-OWFN-08B06-12p
Update 2012-06-13-1640 ET=======
Bridge line information: 866-740-1260 Passcode 273-2784#
Participants From NRC: HQ - Karl Feintuch, Istvan (Steve) Frankl, Leta Brown, Harold Walker; and Call-in = George Lapinski; Rossnyev Alvarado From DEK: Craig Sly Bill Eakin, John Harrell, Bill Kohlroser; Tom Breene The discussion centered on the influence of the control rod drive mechanism (CRDM) cooling fans on the predicted cool down rate of the reactor vessel following the postulated LRA. DEK will provide a summary of the issues for NRC staff reviewers working on ME7110.
DEK is examining the preparation of a supplement to replace affected text currently in the existing ME7110 docketed documents to enable ME7110 to move forward in a timely schedule. NRC staff will evaluate (1) whether additional Technical Branches would need to be involved in the review of the changed application and (2) the impact of the changes on the review efforts already accomplished and newly anticipated as a result of the changed information.
Update 2012-06-13-1040 ET=======
IMPORTANT UPDATE = ME7110 PROJECT TEAM NEEDS TO ASSEMBLE OR CALL IN TO O-8B6 @ 3 PM 6/13/2012 PROJECT REVIEW
Craig Sly called me this morning to describe a problem whose impact is a minimum of 2-3 months delay in project schedule while Dominion Energy Kewaunee (DEK) addresses new information about the Locked Rotor Accident (LRA) that impact (primarily) AADB (Mark Re: LRA details and Leta Re: responding to RAII Brown-004) and other branches by delayed responses to RAI items. Currently, Alva-008,-009 and Torres-004 through -012 RAI responses will be delayed due to concurrence processing until end of June, from planned 6/15/2012. The changed LRA assumptions increase dose to the control room. The solutions best case is a 2-3 month delay in the project and worst case is a 10 month delay [if thermal hydraulics calculations are redone]
, in which case DEK would withdraw ME7110 [and resubmit at a later date].
DEK seeks a discussion with us at 3 PM today to describe the issue whose solution appears to be removing
[diffusers and / or] mufflers from the steam relief valves to accelerate relief steam flow rate out of the relief valves. These mufflers, or diffusers, appear to be for the purpose of noise abatement and their history and requirements that they satisfy are being researched (They date from 1981, at least).
2 Please respond with your ability to attend in person or by call-in. I will update with a bridge line. Craig Sly of DEK is attempting to assemble his technical personnel for the discussion this afternoon, as am I.
Note meeting room location. Forward the invitation as needed.
Hearing Identifier:
NRR_PMDA Email Number:
389 Mail Envelope Properties (26E42474DB238C408C94990815A02F098DA88FC341)
Subject:
ME7110 - Kewaunee - Chi-Over-Q - Record of Conference Call - Wednesday, June 13, 2012 3:00 PM Sent Date:
6/13/2012 6:31:49 PM Received Date:
6/13/2012 6:31:51 PM From:
Feintuch, Karl Created By:
Karl.Feintuch@nrc.gov Recipients:
"Feintuch, Karl" <Karl.Feintuch@nrc.gov>
Tracking Status: None Post Office:
HQCLSTR01.nrc.gov Files Size Date & Time MESSAGE 3291 6/13/2012 6:31:51 PM Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received: