License Amendment Request 244: Proposed Revision to Radiological Accident Analysis and Control Room Envelope Habitability Technical Specifications
ML11252A521
Person / Time
Site: Kewaunee 
Issue date: 08/30/2011
From: Price A
Dominion Energy Kewaunee
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
11-025A, LAR 244, TAC ME7110
Download: ML11252A521 (5)


Text

Dominion Dominion Energy Kewaunee, Inc.

5000 Dominion Boulevard, Glen Allen. VA 23060 August 30, 2011 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Serial No. 11-025A LIC/CDS/RO Docket No.: 50-305

.;..License No..: DP -43" DOMINION ENERGY KEWAUNEE, INC.

KEWAUNEE POWER STATION LICENSE AMENDMENT REQUEST 244: PROPOSED REVISION TO RADIOLOGICAL ACCIDENT ANALYSIS AND CONTROL ROOM ENVELOPE HABITABILITY TECHNICAL SPECIFICATIONS By letter dated July 25, 2011 (ML11222A123), Dominion Energy Kewaunee, Inc. (DEK) requested an amendment to Facility Operating License Number DPR-43 for Kewaunee Power Station (KPS).

This proposed amendment would revise the KPS Operating License by modifying the Technical Specifications (TS) and the current licensing basis (CLB) to incorporate changes to the current radiological accident analysis (RAA) of record. This proposed amendment would revise the current RAA for the design-basis accidents (DBAs) described in Chapter 14 of the KPS Updated Safety Analysis Report (USAR).

This amendment would also fulfill a commitment made to the NRC in response to Generic Letter 2003-01, "Control Room Habitability" (references 1 and 2).

The commitment stated that DEK would submit proposed changes to the KPS TS based on the final approved version of TSTF-448, "Control Room Habitability."

The purpose of this letter is to re-submit the amendment request.

The originally submitted amendment request contained Attachment 2, "Marked-up Operating License and Technical Specification Pages." Due to an apparent printing error, some of the markups in the originally submitted Attachment 2 are not visible.

The remainder of this submittal is an unchanged version of what DEK submitted in its letter dated July 25, 2011. This submittal replaces the submittal dated July 25, 2011 in its entirety.

Enclosed is a compact disc (CD) containing this letter's Attachments and Enclosure. contains a description, safety evaluation, significant hazards consideration determination, and environmental considerations analysis for the proposed changes. contains marked-up Technical Specification pages.

contains marked-up Technical Specification Bases pages for information. Attachment 4 contains the revised RAA. contains an evaluation of two new manual actions credited in the revised RAA. contains the meteorological data A / o 19es~y~o27'e ai

Serial No. 11-025A Page 2 of 5 used to determine the atmospheric dispersion factor (X/Q) values used in the revised RAA and program files used to analyze the data (ARCON96 RSF and LOG files).

DEK requests approval of the proposed amendment by August 30, 2013.

Once approved, the amendment will be implemented within 90 days.

The KPS Facility Safety Review Committee has approved the. proposed. change and a copy of this submittal has been-provided to theo.. State of Wis consin in accordance with 10 CFR 50.91(b).

If you have questions or require additional information, please contact Mr. Craig Sly at 804-273-2784.

Very truly yours, J.

a rice Vi geP sident-Nuclear Engineering COMMONWEALTH OF VIRGINIA COUNTY OF HENRICO The foregoing document was acknowledged before me, in and for the County and Commonwealth aforesaid, today by J. Alan Price, who is Vice President Nuclear Engineering of Dominion Energy Kewaunee, Inc.

He has affirmed before me that he is duly authorized to execute and file the foregoing document in behalf of that Company, and the statements in the document are true to the best of his knowledge and belief.

Acknowledged before me this v*iay of -AUS 6 4-

,2011.

My Commission expires:______________

GInger Lynn Ruh*rfrd" Notary Public NOTARY PUBLIC Commonwealth of Virginia Reg. # 310847 My Commission Expires 4/30/2015

Serial No. 11-025A Page 3 of 5 Attachments:

1.

Discussion of Change, Safety Evaluation, Significant Hazards Determination, and Environmental Considerations

2.

Marked-Up Operating License and Technical Specifications Pages

3.

Marked-Up Technical Specifications Bases Pages

4.

Radiological Accident Analysis and Discussion of Associated Technical Specification-Change..s,.

5.

Evaluation of New Proposed Manual Actions

Enclosure:

1.

Data Files: Kewaunee Power Station, Meteorological Data, 2002 - 2006, X/Q Calculation Support Enclosed with this letter is a compact disk (CD) which contains this submittal's Attachments and Enclosure, labeled:

Dominion Energy Kewaunee, Inc.

Kewaunee Power Station License Amendment Request 244 Proposed Revision to Radiological Accident Analysis and Control Room Envelope Habitability Technical Specifications Serial No. 11-025A Docket No.: 50-305 License No.: DPR-43 August 30, 2011 The enclosed CD contains the following files: (Please note that files 007-013 and the file folder containing ARCON96 RSF & LOG Files below are Data Files for use by the NRC staff in reviewing this amendment request).

File Name Description File Sensitivity Size 001 Attachment 1.pdf Discussion of Change, Safety 175 KB publicly available Evaluation, Significant Hazards Determination, and Environmental Considerations 002 Attachment 2.pdf Marked-Up Operating License

.85 KB publicly available and Tech Spec Pages 003 Attachment 3.pdf Marked-Up Tech Spec Bases 184 KB publicly available Pages 004 Attachment 4.pdf Radiological Accident Analysis 800 KB publicly available and Discussion of Associated Technical Specification Changes 005 Attachment 5.pdf Evaluation of New Proposed 79 KB publicly available Manual Actions

Serial No. 11-025A Page 4 of 5 File Name Description File Sensitivity Size 006 Enclosure 1.pdf Description of Data Files; Met.

92 KB publicly available Data File Structure, and ARCON 96 RSF and LOG Files 007 BaseMetData.txt 2002-2006 Base Met Data 3,510 KB publicly available 008 PAVANDInputs.txt PAVAND Input Files 8 KB publicly available 0091 PAVANDInputspdf PAVAND Inputs 175KB publicly available.e (description/explanation) 010 PAVANDMetData.pdf 2002-2006 Met Data Joint 114 KB publicly available Frequency Distribution PVAND Input 011 PAVANDOutput.pdf PAVAND Output File 287 KB publicly available 012 PAVANDOutput.txt PAVAND Output File 473 KB publicly available 013 ARCON96Data.txt 2002-2006 Met Data 1,584 KB publicly available 014 File Folder ARCON96 RSF & LOG Files 180 KB publicly available

References:

1.

Generic Letter 2003-01, "Control Room Habitability," dated

[ADAMS Accession No. ML031620248]

June 12, 2003.

2.

Letter from Craig W. Lambert (NMC) to Document Control Desk (NRC), "Generic Letter 2003-01:

Control Room Habitability -

Supplemental Response," dated April 1, 2005. [ADAMS Accession No. ML050970303]

Commitments made by this letter:

1. The following guidelines will be included in the assessment of systems removed from service during movement of recently irradiated fuel:
a. During fuel handling of recently irradiated fuel, ventilation system and radiation monitor availability (as defined in NUMARC 91-06) will be assessed, with respect to filtration and monitoring of releases from the fuel.

Following shutdown, radioactivity in the fuel decays away fairly rapidly. The basis of the Technical Specification operability amendment is the reduction in doses due to such decay. The goal of maintaining ventilation system and radiation monitor availability is to reduce doses even further below that provided by the natural decay.

b. A single normal or contingency method to promptly close primary or secondary containment penetrations will be developed.

Such prompt methods need not completely block the penetration or be capable of resisting pressure.

The purpose of the "prompt methods" mentioned above is to enable ventilation systems to draw the release from a postulated fuel handling accident in the proper direction such that it can be treated and monitored.

Serial No. 11-025A Page 5 of 5

2. DEK will provide the necessary administrative controls to ensure that in the event of a fuel handling accident inside containment, any open containment penetration flow paths can and will be promptly closed (within 30 minutes). However, if it is determined that closure of any containment penetrations would represent a significant radiological hazard to the personnel involved; the decision may be made to forgo the closure of the affected penetration(s).
3. DEK will provide the necessary administrative procedures to:ensure tati e

event of a fuel handling accident inside containment, an open equipment hatch can and will be promptly closed following containment evacuation (within 45 minutes). However, if it is determined that closure of the containment hatch would represent a significant radiological hazard to the personnel involved; the decision may be made to forgo the closure of the containment hatch.

4. DEK will relocate the current technical specification requirements related to Radiation Monitor R-23 to the KPS Technical Requirements Manual as part of the implementation of this amendment.

The carbon copy (cc:) recipients of this letter will receive a compact disk (CD) which contains this submittal's Attachments and Enclosure.

cc:

Regional Administrator, Region III U. S. Nuclear Regulatory Commission 2443 Warrenville Road Suite 210 Lisle, IL 60532-4352 Mr. Karl D. Feintuch NRC Project Manager U.S. Nuclear Regulatory Commission One White Flint North, Mail Stop 08-H4A 11555 Rockville Pike Rockville, MD 20852-2738 NRC Senior Resident Inspector Kewaunee Power Station Public Service Commission of Wisconsin Electric Division P.O. Box 7854 Madison, WI 53707