ML12066A139

From kanterella
Jump to navigation Jump to search

Summary of Telephone Conference Call Held on March 1, 2012 Between the NRC and NextEra Energy Seabrook Llc., Concerning the Drai Pertaining to the Seabrook Station, LRA Environmental Review
ML12066A139
Person / Time
Site: Seabrook 
Issue date: 03/20/2012
From: Michael Wentzel
License Renewal Projects Branch 2
To:
NextEra Energy Seabrook
Wentzel M, 415-6459
References
TAC ME3959
Download: ML12066A139 (5)


Text

~p.R REG U{

UNITED STATES

~(,'"

"I"

..~",o~.L NUCLEAR REGULATORY COMMISSION

~

C'>

WASHINGTON, D.C. 20555-0001

<l; 0

1 March 20,2012

~

~

~?

...0

        • 1<

LICENSEE:

NextEra Energy Seabrook, LLC FACILITY:

Seabrook Station

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON MARCH 1, 2012, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND NEXTERA ENERGY SEABROOK, LLC, CONCERNING THE DRAFT REQUEST FOR ADDITIONAL INFORMATION PERTAINING TO THE SEABROOK STATION, LICENSE RENEWAL APPLICATION ENVIRONMENTAL REVIEW (TAC. NO.

ME3959)

The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of NextEra Energy Seabrook, LLC held a telephone conference call on March 1, 2012, to discuss and clarify the staff's request for additional information (RAls) concerning the Seabrook Station, license renewal application. provides a listing of the participants and Enclosure 2 contains a listing of the RAI discussed with the applicant, including a brief description on the status.

The applicant had an opportunity to comment on this summary.

1IfMliAV Michael Wentzel, pQect Manager Projects Branch 2 Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-443

Enclosures:

As stated cc w/encls: Listserv

TELEPHONE CONFERENCE CALL SEABROOK STATION LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS MARCH 1, 2012 PARTICIPANTS AFFILIATIONS Michael Wentzel Richard Cliche U.S. Nuclear Regulatory Commission NextEra Energy Seabrook, LLC.

ENCLOSURE 1

REQUESTS FOR ADDITIONAL INFORMATION LICENSE RENEWAL APPLICATION MARCH 1, 2012 The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of NextEra Energy Seabrook, LLC (NextEra) held a telephone conference call on March 1, 2012, to discuss and clarify the following request for additional information (RAI) concerning the license renewal application environmental review.

Seabrook RAI for Cooling System Alternatives In response to public comments received on the Seabrook Station (Seabrook) license renewal application draft supplemental environmental impact statement (SEIS), from both the Environmental Protection Agency (EPA), Region 1 (ML11304A059) and National Oceanic and Atmospheric Administration's (NOAA) National Marine Fisheries Service (NMFS)

(ML11304A057), the NRC will evaluate the environmental impacts of a range of alternatives for structural and operational modifications to the Seabrook cooling system that could reduce adverse impacts to aquatic resources. For example, EPA recommended that the each alternative characterize the "number of organisms to be impinged and/or entrained by the intake structure under the different alternatives." This evaluation will be included in the final SEIS for the Seabrook license renewal application. The NRC does not have the regulatory authority to implement the requirements of the Clean Water Act. As stated in the EPA's letter to the NRC, the evaluation will not "purport to provide or suggest the answers to the ultimate permitting questions that EPA must address under the Clean Water Act."

In order to assist the NRC in the preparation of the response to these comments, please provide copies of any assessment(s) of the environmental impacts associated with the construction and operation of closed-cycle cooling system alternatives, including alternatives for structural and operational modifications to the Seabrook cooling system. Of particular interest are any assessments evaluate the potential environmental impacts to land use, air quality, water resources, terrestrial and aquatic resources (including the estimated number of organisms to be impinged and/or entrained by the intake structure under the different alternatives), human health, socioeconomics, transportation, aesthetics, cultural resources, and waste management.

Discussion: Prior to the phone call, NextEra provided NRC a 2008 document entitled, "Cooling Water Intake Structure Information Document," for review. This document has previously been submitted by NextEra in response to the staff's October 29, 2010, RAls. The Agencywide Documents Access and Management System (ADAMS) numbers for the report are ML110100311 (Cover through Appendix A) and ML110100312 (Appendix B through Appendix E). Since this document has already been submitted on the Seabrook docket, and no further information is needed at this time, the NRC agreed on the conference call to withdraw the draft RAI on this matter.

ENCLOSURE 2

March 20, 2012 LICENSEE:

NextEra Energy Seabrook, LLC FACILITY:

Seabrook Station

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON MARCH 1, 2012, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND NEXTERA ENERGY SEABROOK, LLC, CONCERNING THE DRAFT REQUEST FOR ADDITIONAL INFORMATION PERTAINING TO THE SEABROOK STATION, LICENSE RENEWAL APPLICATION ENVIRONMENTAL REVIEW (TAC. NO.

ME3959)

The U.S. Nuclear Regulatory Commission (!\\IRC or the staff) and representatives of NextEra Energy Seabrook, LLC held a telephone conference call on March 1,2012, to discuss and clarify the staff's request for additional information (RAls) concerning the Seabrook Station, license renewal application. provides a listing of the participants and Enclosure 2 contains a listing of the RAI discussed with the applicant, including a brief description on the status.

The applicant had an opportunity to comment on this summary.

IRA!

Michael Wentzel, Project Manager Projects Branch 2 Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-443

Enclosures:

As stated cc w/encls: Listserv DISTRIBUTION: See next page ADAMS Accession No'.. ML12066A139 OFFICE LA:RPB2DLR PM:RPB2DLR BC:RPB2:DLR PM:RPB2DLR

!\\lAME IKing MWentzel DWrona MWentzel DATE 3/12/12 3/15/12 3/19/12 3/20/12 OFFICIAL RECORD COpy

Memorandum to NextEra Energy Seabrook, LLC, from M. Wentzel dated March 20, 2012

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON MARCH 1, 2012 BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND NEXTERA ENERGY SEABROOK, LLC, CONCERNING THE DRAFT REQUEST FOR ADDITIONAL INFORMATION PERTAINING TO THE SEABROOK STATION, LICENSE RENEWAL APPLICATION ENVIRONMENTAL REVIEW (TAC. NO.

ME3959)

DISTRIBUTION:

HARD COPY:

DLR RF E-MAIL:

PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRarb Resource RidsNrrDlrRapb Resource RidsNrrDlrRasb Resource RidsNrrDlrRerb Resource RidsNrrDlrRpob Resource RidsNrrDraApla Resource MWentzel ACunanan DMorey DWrona JLamb DMclntyre,OPA EDacus,OCA MSpencer, OGC WRaymond, RI DTifft, RI NMcNamara, RI NSheehan, RI DScrenci, RI JJohnson, RI ABurritt, RI