I -6 *Final Status Survey Final Report Phase 11 Appendix Al 3 Survey Unit Release Record 9537-0000, Permitted Landfill Area February 2005 Oy CYAPCO FINAL STATUS SURVEY RELEASE RECORD PERMITTED LANDFILL SURVEY UNIT 9537-0000 Prepared By: Date: I.( 9 -I FSS Engineer Reviewed FMb aieer K3 Date: 2AS \Date: A -VS Approved By: Revision 1 CYAPCO FINAL STATUS SURVEY RELEASE RECORD PERMITTED LANDFILL SURVEY UNIT 9537-0000 Prepared By: FSS Engineer Date: I.(s3 'I Reviewed B , I FAppe ySeer: Approved By: I ~~ t Lead Date:_____\
Date: A-I-Revision 1 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD TABLE OF CONTENTS 1. SURVEY UNIT DESCRIPTION
.....................................................
3 2. CLASSIFICATION BASIS .....................................................
3 3. DATA QUALITY OBJECTIVES (DQO) ..............................................
5 4. SURVEY DESIGN ..............................
7 5. SURVEY IMPLEMENTATION
............................
0 6. SURVEY RESULTS ...........................
11 7. QUALITY CONTROL ...........................
14 8. INVESTIGATIONS AND RESULTS ...........................
14 9. REMEDIATION AND RESULTS ...........................
15 10. CHANGES FROM THE FINAL STATUS SURVEY PLAN .15 11. DATA QUALITY ASSESSMENT (DQA) .15 12. ANOMALIES
.16 13. CONCLUSION
.17 14. ATTACHMENTS
.18 14.1 Attachment 1 -Figures (7 pages including cover)14.2 Attachment 2- Sample and Statistical Data (138 pages including covers)Revision I PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD 1. SURVEY UNIT DESCRIPTION Survey Unit (SU) 9537-0000, (Permitted Landfill) is designated as Final Status Survey (FSS) Class 2 and consists of approximately 850 m 2 (0.21 acres) of open land area located approximately 0.85 miles from the center of the Haddam Neck Plant (HNP) Containment Building (see Attachment 1-Figure 1). Survey Unit 9537-0000 is at the south end of an excavated sandpit and west of the former pistol range (SU 9536-0000).
The landfill was constructed as a north-south trench approximately 120 feet long by 50 feet wide. The area topography was altered and graded to what was assumed to be the original grade. The area slopes upward to a wooded area (SU 9523-0000) and was cleared of all scrub growth and reseeded to prevent erosion.The reference coordinates associated with the Permitted Landfill are E041 through E047 by S129 through S134 (refer to License Termination Plan Section 5.4.4). The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS).The historic files indicate that soil and spoils were transported to the general vicinity of this area as early as 1976. Specific details relevant to date or time period and exact location of placement were not available.
Excavation and trenching prior to FSS was performed in this survey unit for the purposes of removing materials and spoils (e.g., concrete, asphalt, metal, etc.).Radiological surveys for contamination did not identify radioactive material on these items. The Permitted Landfill area was staked out and measured during the 1997 scoping survey. The current area of the Permitted Landfill was assumed to be 850 m 2 based on the staked positions.
- 2. CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10,"Survey Unit Classification." The historical information and scoping analyses results provide sufficient data to designate SU 9537-0000 as Class 2 in August 2001.The "Classification Basis Summary" conducted for SU 9523-0000 consisted of: a) A review of the IOCFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and "Historic Site Assessment Supplement, " c) Historic and current survey records review, d) Personal interviews, e) Visual inspections and a "walk down." Revision I 3 Revision 1 3 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD A review of the IOCFR50.75 (g) (1) database report identifies no events that might have impacted this survey unit. The only listing was a reference to scoping survey data. These data were included in the IOCFR50.75 (g) (1)database for historical purposes and to facilitate final status survey planning for this survey area.A review of the "Initial and Supplemental Characterization Reports " as well as the previous "Classification Basis Summaries" indicates that the area was established for the disposal of bulky waste on Connecticut Yankee property.The permit limited the use of the disposal area to include only bulky wastes such as scrap metals, wood, rubble, land-clearing wastes, and demolition wastes. Furthermore, the permit bars the deposition of garbage, sludge, putrescible material, and radioactive material in the area. The Permitted Landfill is thought to have never been used for the purposes of bulky waste disposal.
The origin of the materials excavated there and timeframe of placement is unknown.A Survey Sampling Work Plan (SSWP N2. BCY-SSWP-03-08-001) was developed and implemented during September 2003 to obtain the necessary data of sufficient data quality for FSS planning purposes.
Thirty-five (35) samples were obtained through biased sampling over a simple grid design approximating a triangular pattern. The samples were analyzed at HNP by gamma spectroscopy.
The only radionuclide identified in the samples was Cs-137, which was identified just once and at very low levels. The concentrations of Cs-137 found in the soil were below those concentrations determined from off-site locations as documented by Health Physics Technical Support Document (TSD) BCY-HP-0063, "Background Cs-137 Concentration in Soilr (see Table 1).Table 1 -Basis Statistical Quantities for Cesium-137 from the Characterization Survey Cesium-137 Parameter (pCilg)Minimum Value: 0.0001 Maximum Value: 0.1290 Mean: 0.0389 Median: 0.0370 Standard Deviation:
0.0252 Haddam Neck Plant staff conducted personnel interviews during the historical site assessment to ascertain the history of the Permitted Landfill.
Individuals responding to the questionnaire stated that spoils originating from construction activities such as new building construction, addition to existing buildings and general site maintenance and repairs were brought to the shooting range landfill.Revision I 4 Revision 1 4 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD FSS Engineers performed a walkdowvn of the area. The FSS staff indicated that the area is an open space with little or no obstructions.
Materials and spoils have been removed from the area. Most of the area is sand based, although rock masses have been identified during trenching.
At the time of FSS, the dose impact from groundwater contamination was not considered.
The characterization data would have been sufficient to justify final designation as Class 3. Nevertheless, the survey design maintained the initial designation as a Class 2 to be prudent.3. DATA QUALITY OBJECTIVES (DQO)The primary objective of the Final Status Survey Plan (FSSP) was to demonstrate that the level of residual radioactivity in Survey Unit 9537-0000 did not exceed the release criteria specified in the License Termination Plan (LTP), was below the 10 mrem/yr Administrative Level Derived Concentration Guideline Level (DCGL), and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).FSS design and planning endorsed the use of the Data Quality Objective (DQO)process as described by the LTP, Procedure RPM 5.1-11, "Preparation of Final Status Survey Plan," and the "Miulti-Agency Radiation Survey and Site Investigation Manual" (MARSSIM).
A summary of the main features of the DQO process are provided herein.The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis.
Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition.
The baseline condition is technically known as the null hypothesis.
Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection.
In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria.
Rejection of the null hypothesis would satisfy the release criteria objective of the FSS.Characterization efforts in nearby areas have included analysis for Hard-to-Detect (HTD) radionuclides.
In some cases, HTD radionuclides were reported above the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty-2a).
Comparing reported maximum concentrations to the soil DCGLs shows no impact on FSS design. This conclusion was based on the very low percentage of the HTD radionuclide to the soil DCGL.The DQO process determined that Cs-137 would be the radionuclide of concern during the 9537-0000 FSS process. Additionally, to provide conservatism, the Base Case DCGLs for radionuclides in soil was reduced by 60% to establish the Administrative Level DCGL.Revision I 5s Revision I 5
- PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL. Survey instrument response checks were performed before issue and afler the instrument had been used. Control and accountability of survey instruments were maintained to assure the quality and prevent the loss of data.Laboratory DQOs and analysis results were reported as actual calculated results.Results reported as less than Minimum Detectable Concentration
(<MDC)would not be accepted for FSS. Sample report summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty of two standard deviations (2a), laboratory data qualifiers, units, and the required and observed MDC (see Table 2).Table 2- FSS DCGL Values and Required Minimum Detectable Concentrations Radionuclide Base Case Soil Administrative Level Required MDC DCGL (pCI/g) DCGL (pCilg) (2) (pCi/g) (3)H-3 4.12E+02 1.65E+02 1.65E+OI C-14 5.66E+00 2.26E+00 2.26E-O01 Mn-54 1.74E+01 6.96E+00 6.96E-O 1 Fe-55 2.74E+04 1.I1OE+04 1.11OE+03 Co-60 3.81 E+OO 1.52E+0O 1.52E-O1 Ag-108im 7.14E+00 2.86E+00 2.86E-O1 Ni-63 7.23E+02 2.89E+02 2.89E+O1 Sr-90 1.551E+OO 6.20E-01 6.20E-02 Nb-94 7.12E+00 2.85E+00 2.85E-O1 Tc-99 1.26E+01 5.04E+00 5.04E-O1 Cs-134 4.67E+00 1.87E+00 1.87E-O1 Cs-137 7.91 E+OO 3.16E+00 3.16E-O1 Eu-152 1.OIE+OI 4.04E+00 4.04E-O1 Eu-154 9.29E+00 3.72E+00 3.72E-O1 Eu-155 3.92E+02 1.57E+02 1.57E+O1 Pu-238 2.96E+01 1.18E+O1 1.18E+OO Pu-239/240 2.67E+01 1.07E+01 1.07E+OO Pu-241 8.70E+02 3.48E+02 3.48E+O1 Am-241 2.58E+01 1.03E+01 1.03E+OO Cm-243/244 2.90E+01 1.16E+01 1.1 6E+OO (1) The Base Case DCGLs for soil are specified by the LUP in Chapter 6.(2) The Administrative Level DCGL is 40% of the Base Case DCGL.(3) The required MDC was 10% of the Administrative Level DCGL.Revision I 6 Revision 1 6 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD 4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. To assist the FSS Engineers when preparing survey plans for FSS, guidance is provided in Procedure RPM 5.1-11.By design, the FSSP meets the ALARA criteria for soils as specified in Chapter 4 of the LTP.The LTP specifies that scanning will be performed in a combination of systematic and judgmental measurement for a Class 2 land area and cover 10%to 100% of the area. The fraction of scanning coverage was determined during the DQO process with the total amount and location(s) based on the likelihood of finding elevated activity during FSS. Elevated areas of residual radioactivity were not considered likely based on characterization data. Nevertheless, given the historical use of the landfill the decision was made to scan 100% of the area.The scan design consisted of twenty-nine (29) evenly spaced strips oriented north to south. Scans were also prescribed for a one (1) meter radius around each random and biased Sample Measurement Location (SML).Thirty-five (35) data points were used to determine the radiological concentration variability in this survey unit. The samples were collected through biased sampling over a simple grid design.Radionuclide-specific analyses of soil samples collected from this survey unit and adjacent land areas with similar history and physical characteristics have identified only a few radionuclides, principally Cs-137. The data collected prior to FSS indicated that the remaining radionuclides listed in Table 2 would not be present in quantities greater than 5% of the applicable Base Case DCGL in this survey unit at the time of FSS. It was unlikely that the aggregate concentration of the remaining radionuclides would exceed 10%; therefore, only Cs-137 was used in the survey planning of SU 9537-0000.
The use of the 5% and 10% rule is consistent with the development of surrogate ratio DCGLs as described in the LTP.The DQO process determined that Cs-137 would be the radionuclide of concern during the 9537-0000 FSS process. The Operational DCGL of 3.16 pCi/g for Cs-137 was used to demonstrate compliance with the release criteria.Surrogate DCGLs are not required for this survey unit because of the radionuclide specific analysis and radionuclide de-selection in accordance with the 5% and 10% rule.The Elevated Measurement Comparison (EMC) does not apply to this survey unit since discrete, elevated areas of contamination are not expected.The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation.
This approach was conservative since it included background Cs-137 as part of the sample set.Revision 1 7 Revision I 7 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Surface Samples for FSS." Survey design specified fifteen (15) surface soil samples for the Sign Test non-parametric statistical testing.Four (4) Judgmental or biased depth samples were selected in locations randomly using the Microsoft Excel "RANDBETWEEN" functions.
The collection of the "at depth" samples was to account for soil disturbance as a result of material and spoils removal from the area prior to FSS. In addition, the Permitted Landfill was originally constructed as a north-south trench approximately 120 feet long by 50 feet wide to a depth of 5 feet. The four (4)samples were to be collected to the depth of the original grade or refusal, homogenized and analyzed by gamma spectroscopy.
The number of judgmental samples represented 25% percent of the number of samples that would be used for non-parametric statistical testing.Although Procedure RPM 5.1-11 only specified that 5% of the samples be selected for HTD analysis, two (2) soil samples or 13% were randomly selected for HTD radionuclide analysis by using the Microsoft Excel"RANDBETWEEN" function.
Each sample would be sent for a full suite analysis of the HTD radionuclides specified in the LTP, Table 2-12,"Radionuclides Potentially Present at Haddam Neck Plant." The implementation of survey specific quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey, " included the collection of two (2) soil sample for "split sample" analysis by the off site laboratory.
This location was selected randomly using the Microsoft Excel "RANDBETWEEN" function.
The number of quality control soil samples was determined to be 13% of fifteen (15) samples, rounded up to the next whole number.The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Samnple Locations for FSS." Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 2 area.Sample location and scan areas were identified using AutoCAD-Lt 0 a commercially available plotting software with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample and scan locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.Revision I 8 Revision 1 8 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD Table 3 -Sample Measurement Locations (SML) with Associated GPS Coordinates.
Designation Northing Easting 9537-0000-001 235864.1 673166.7 9537-0000-002 235841.1 673153.4 9537-0000-003 235841.1 673180 9537-0000-004 235841.1 673206.6 9537-0000-005 235818 673166.7 9537-0000-006 235818 673193.3 9537-0000-007 235795 673153.4 9537-0000-008 235795 673180 9537-0000-009 235772 673140.1 9537-0000-010 235772 673166.7 9537-0000-011 235772 673193.3 9537-0000-012 235748.9 673153.4 9537-0000-013 235748.9 673180 9537-0000-014 235725.9 673140.1 9537-0000-015 235725.9 673166.7 For this Class 2 survey unit, the "Investigation Level" for area scanning and soil sample measurement results are those levels specified in LTP, Table 5-8,"Investigation Levels." The Lower Bound of the Gray Region (LBGR) was adjusted in accordance with Procedure RPM 5.1-11 to 0.98 of the Administrative Level DCGL to maintain the relative shift (A/a) in the range of I and 3. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.Table 4 provides a synopsis of the survey design.Revision I 9 Revision 1 9 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD Table 4 -Synopsis of the Survey Design Feature Design Criteria Basis Survey Unit Land Area 850 m GPS measurements of area Type I and Type 2 were 0.05, sigma was 0.0252, the Number of Measurements 15 LBGR was adjusted to 0.98 (3.11) to maintain Relative Shift in the range of 1 and 3 Grid Spacing 8.09 m Based on triangular grid Interval Spacing 7.01 m Based on triangular grid DCGL3.16 pCi/g Operational DCGL applied DCGL _Cs-137 to field data (1)Scan Survey Area 100% Based on historical use of Coverage landfill area Scan Investigation Level Detectable over Based on achieving the background Administrative Level DCGL (I) The Operational DCGL was based on achieving an administrative level that was 40%0 of the soil DCGL and assuming no impact from radioactive contamination in groundwater or from buried concrete debris.5. SURVEY IMPLEMENTATION Final status survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 24265-000-GEN-0000-00134-000.
The WP&IR package included a detailed FSSP, job safety analysis, job planning checklist and related procedures for reference.
Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The"Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.Survey activities occurred November 11 through November 14, 2003.The scan areas were marked out using GPS coordinates consistent with the Connecticut State Plane System and scanned for elevated readings (see Attachment 2 for Scan Area Results).
Scanning was performed with an Eberline E-600 using a SPA-3 sodium iodide detector.
The E-600 was operated in the rate-meter mode and used with audio response.
The probe was positioned as close to the ground as possible and was moved at a scan speed of about 0.5 meters per second.Using GPS coordinates, SMLs were identified and marked with a surveyor's flag for identification.
At each SML, a one (1) meter radius around the sample flag was scanned for elevated radiation levels.Fifteen (15) surface soil samples were collected in random locations and packaged in accordance with HNP Procedure RPM 5.1-3, "Collection of Surface and Subsurface Soil, Shoreline Sediment, Asphalt and Liquid samples for Scoping, Characterization, and Final Statuts Survey," and FSS design.Samples were controlled, transported, stored, and transferred to the off site Revision I 10 Revision I 10 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of C'ustody for Scoping, Characterization and Final Status Survey Samples. " Two (2) samples (OOIF and 0014F) were randomly selected for HTD radionuclide analysis.Four (4) biased soil samples (005F02, 007F02, 01 1F02, and 014F02) were taken to the depth of the limit of disturbance where construction activities had occurred in the survey unit. These samples were analyzed by gamma spectroscopy at the HNP.The implementation of survey specific quality control measures included the collection of samples 002F and 006F for "split sample" analysis by the off site laboratory.
- 6. SURVEY RESULTS No elevated readings were identified during scanning the SMLs. Five (5) Scan Areas contained areas with elevated readings, which prompted the collection of investigation samples from these locations.
The investigation results are discussed in Section 8 of this report. Table 5 provides an overview of the Scan Area survey. All scan area results are provided in Attachment 2.Revision 1 I1I PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD Table 5- Scan Area Results Highest Scan Logged Investigation Read Investigation Area Reading Leve R Sample (cpm) (MDC-cpm)
Identification 1 6,850 8,470 2 7,750 8,800 _3 8,090 8,470 _ _ _4 7,570 8,800 _ _ _5 7,200 8,470 ___6 7,390 8,800 ___7 6,640 8,470 ___8 7,790 8,800 _ _ _9 9,430 8,470 ER-1 9,520 8,800 ER-2 10 9,670 8,800 ER-3 9,870 8,800 ERA 11 6,270 8,470 12 9,630 8,800 ER-5 13 15,200 8,470 ER-6 14 7,210 8,260 _ _ _15 7,640 9,280 _ _ _16 7,120 8,260 _ _ _17 7,650 9,280 _ _ _18 7,010 8,260 _ _ _19 6,950 9,280 _ _ _20 7,180 8,260 _21 7,510 9,280 _22 8,080 8,260 _23 7,090 9,280 _24 6,980 8,260 ER-7 25 7,320 9.28 ___26 6,710 8.26 ___27 7,180 9.28 ___28 6,810 8.26 __29 10,300 9.28 Revision I 12 Revision 1 12 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD The off site laboratory employed for the radiological analyses of samples was STL-Richland, Richland, Washington.
The laboratory analyzed the fifteen (15)samples taken for non-parametric statistical testing, the associated duplicates, and the biased samples using gamma spectroscopy.
Gamma spectroscopy analysis was performed to the required MDC. Gamma spectroscopy results identified some radionuclides meeting the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty-2a).
Cesium-137 was identified in five (5) of the fifteen(15) samples (33%). The results of gamma spectrometry analysis for a majority of the samples indicated Cs-137 at levels consistent with concentrations of Cs-137 found in soil at offsite locations within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063.
The data shows that Co-60 was reported as less than 2% of the Administrative Level DCGL on all samples collected.
Sample analysis did not indicate any anomalies requiring further investigation.
A summary of the sample results is provided in Table 6.Table 6- Su mary of Soil Sample Results CS-137 co-60 fDG 'Sample Number. fDCG (9537-0000-OOlF 0.083 -0.0119 0.026 9537-0000-002F 0.0824 0.0125 0.034 9537-0000-003F 0.0403 0.0133 0.022 9537-0000-004F 0.0187 0.0139 0.015 9537-0000-005F 0.015 0.0099 0.011 9537-0000-006F 0.0174 0.012 0.013 9537-0000-007F 0.01 0.0159 0.014 9537-0000-008F
-0.0007 0.0093 0.006 9537-0000-009F 0.0202 -0.0138 0.006 9537-0000-O0OF
-0.0029 0.0088 0.006 9537-0000-OlF 0.0338 -0.0104 0.011 9537-0000-012F 0.0085 -0.0122 0.003 9537-0000-013F 0.0264 0.0104 0.015 9537-0000-014F 0.064 0.0071 0.025 9537-0000-015F 0.0234 -0.0073 0.007 (I) f-DCGL~fraction of the Administrative Level DCGL The offsite laboratory processed two (2) samples for HTD analysis as required by the sample plan. The requested analyses including alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. Most analyses met the required MDC with the exception of Sr-90 and C-14. This topic is discussed further in Section 10 and Section 12.In combination with Cs-137 and Co-60, the maximum f-DCGL in the sample set was 0.183 (18.3%) for SML OO1F. No further action or investigations were required (see Table 7).Revision I 13 Revision I 13 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD Table 7-Hard-to-Detect Sample Results pCi/g Sample Fe-55 1H-3 l Pu-241 Sr-90 Tc-99 fDC)GL 9537-0000-001F 7.19 0.0212 -0.0702 0.189 0.157 9537-0000-014F 1.45 0.0659 1.33 --0.04 (I) f-I)CGLfraction of the Administative Level DCGL Four (4) biased samples were collected at locations where construction activities had occurred or had the potential to impact local soils. Gamma spectroscopy analysis was performed to the required MDC. None of the samples exceeded 4% of the Administrative Level DCGL for Cs-137 and Co-60. No further action or investigations were required (see Table 8).Table 8-Biased Sample Results: Cs-137l Co-60 Sample Number pC- f-DCGL('" 9537-0000-005F02
.0 015 0.0099 0.011 9537-0000-007F02 0.0625 0.0199 0.033 9537-0000-01 IF02 0.0338 -0.01 0.004 9537-0000-014F02 0.064 0.0071 0.025 (I) fMDCGL-fraction of the Administrative Level DCGL 7. QUALITY CONTROL The off site laboratory processed the split samples and performed gamma spectroscopy analysis.
Thirteen percent (13%) of the samples were selected for analysis, which exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey. " There was acceptable agreement between field split results. The sample analysis vendor, STL-Richland, Richland, Washington, maintains quality control and quality assurance plans as part of normal operation.
Refer to Attachment 2 for data and data quality analysis results.8. INVESTIGATIONS AND RESULTS Seven (7) localized areas were identified above the investigation level during the scan area survey. Soil samples were collected at each of the locations and analyzed at the offsite laboratory using gamma spectroscopy.
Gamma spectroscopy analysis was performed to the required MDC. Review of the sample analysis results did not identify elevated results. None of the samples exceeded 5% of the Administrative Level DCGL for Cs-137 and Co-60. No further investigation was required (see Table 9).Revision I 14 Revision I 14 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD Trahla OTnvyctfofmnn si"mrpc 'nrlagtpf]
ifn Arafn Ar .O Scan Cs-137 Co-60 f-DCGL(" Sample Number pCi/g pCi/g f________A rea__ _ _ _ _ _ _ _ _ _ _ _ _ _ _9 9537-0000-ERI 0.014 -0.006 0.004 9537-0000-ER2 0.019 -0.002 0.006 10 9537-0000-ER3 0.014 0.013 0.013 9537-0000-ER4 0.012 0.003 0.016 12 9537-0000-ERS 0.011 -0.008 0.004 13 9537-0000-ER6 0.013 0.019 0.017 24 9537-0000-ER7 0.138 0.011 0.05 (1) f-DCGL-fraction of the Administrative Level DCGL 9. REMEDIATION AND RESULTS Historically, no remediation was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey," determined that remediation beyond that required to meet the release criteria to be unnecessary and that the remaining residual radioactivity in soil was ALARA.10. CHANGES FROM THE FINAL STATUS SURVEY PLAN The change made from the LTP, prior to this FSS, was a decrease in the concentrations for the Base Case DCGLSOiS.
The LTP presents DCGLs that correspond to a Total Effective Dose Equivalent (TEDE) of 25 mrem/yr. This survey unit was evaluated against Administrative Level DCGLs that correspond to 10 mrem/yr.The required MDCs for Sr-90 and C-14 could not be reasonably achieved.
The data quality objectives recognized that certain analytical methods might not meet MDC requirements (e.g., C-14 in soil). The MDC were set at 4% of the soil DCGL to be as far below the DCGL as practical.
In accordance with the LTP, a value at 10% of the soil DCGL would have been the desired level of sensitivity.
Review of the data shows C-14 and Sr-90 MDCs to be well below the desired level of sensitivity specified by Section 5.5 of the LTP (i.e., <10% of the applicable soil DCGL) and are therefore acceptable.
- 11. DATA QUALITY ASSESSMENT (DQA)The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment," for completeness and consistency.
The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. All sample results were less than the release criteria.
Therefore, the Sign Test shows that the survey unit passes FSS.Revision 1 15 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2.The preliminary data review consisted of converting the data into units relative to the release criteria (i.e., pCi/g) and calculating basic statistical quantities (e.g., mean, median, standard deviation).
Cesium-137 sample standard deviation was slightly less than the value used for the survey design. This indicates that a sufficient number of samples were collected to achieve the desired power. The range of the data, about 3.2 standard deviations, was not unusually large. The difference between the mean and median was 33% of the standard deviation.
The difference is enough to indicate skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The data follows a relatively normal distribution about the mean value with some positive skewness.All data, assessments, and graphical representations are provided in Attachment 2.12. ANOMALIES All data is considered valid including negative values, zeros, values reported below the MDC and values reported with uncertainties greater than two standard deviations (2a). Some radionuclides have been reported at low concentrations that are statistically significant at the 95% confidence level, but with a relatively high level of uncertainty.
Gamma spectroscopy results identified several radionuclides meeting the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty-2a).
Cesium-134 was frequently identified in sample results. Other radionuclides, such as Am-241, Mn-54, and Eu-155 were identified sporadically.
The offsite laboratory data qualifier unit shows that these radionuclides were analyzed for, however, either the result was less than the MDC or the gamma software did not identify the radionuclide.
These very low-level "detections" may be attributed to false positive noise at the lower limit of the measuring technique.
Two (2) samples were submitted to the offsite laboratory and analyzed for HTD radionuclides.
Hard-to-detect analyses results identified several radionuclides meeting the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty-2u).
Iron-55 and H-3 (tritium) was identified in both samples (100%). Strontium-90, and Tc-99 was identified in SML 001F, Pu-241 in SML 014F. In almost all cases, the magnitude of the analytical bias was less than sample required MDC. By comparison, reported MDCs were less than the required MDCs by factors of two (2) up to 550 (with the exception of Revision I 16 Revision 1 16 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD Sr-90 as described in a Section 10). These very low-level "detections" may be attributed to false positive noise at the lower limit of the measuring technique.
The analysis indicates that Sr-90 was identified in one (1) of the samples.Typically, the levels and geographical locations of the Sr-90, along with Cs-137, found in the analysis are associated with weapons testing and atmospheric fallout. The amounts identified in the report suggest that this is the origin of the Sr-90 along with certain amounts of Cs-137. The Sr-90 value compares favorably with research conducted in other regional areas concerning fallout resultant from nuclear testing in the past as referenced in EPRI Technical Report 1003030, "Determining Background Radiation Levels in Support of Decommissioning Nuclear Power Plants.Plutonium was detected in one (1) of the HTD samples but below the MDC.The likely source of Pu-241 is the release of plutonium from past atmospheric nuclear weapons testing and burn-up and vaporization of the United States SNAP 17A satellite in the atmosphere given the extremely low levels reported.These HTD radionuclides do not represent quantities that would increase the requisite number of samples for non-parametric statistical sampling or cause the survey unit to fail to meet the release criteria.
Sample analysis did not indicate any anomalies requiring further investigation.
The analytical data shows that most of the identified HTD radionuclides were reported as a small fraction of the corresponding soil DCGL. Most radionuclides were reported at levels near or below the required MDC.13. CONCLUSION Survey Unit 9537-0000 has met the DQOs of the FSS. For this survey unit, the ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved.Elevated Measurement Comparison and remediation was not required.The sample data passed the Sign Test. The null hypothesis was rejected.Evaluation of the data shows that none of the FSS design radionuclides or HTD soil concentration values exceeded the Operational DCGL or unity. Although several localized spots exceeded the investigation levels there were no elevated areas based on sample measurements results. No large anomalies were observed in the graphical representation of the data. The survey unit was properly designated as Class 2. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved.This survey unit is not considered impacted by radioactive contamination in groundwater based on location, topography and current hydro-geologic sampling data as referenced in Health Physics TSD CY-HP-0193, "Assessment of Existing Groundwvater Dose for Phase II Release Areas of the Final Status Survey Report. " Revision I 17 Revision 1 17 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD 14. ATTACHMENTS 14.1 Attachment 1 -Figures 14.2 Attachment 2 -Sample and Statistical Data Revision 1 18 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD Attachment 1 Figures m m M --M M M M m m -m ---M- --IZ (VI'711 9-rV I'.m l v- i- Go I- .,*Ish-<,*'I,-=-Z4 r,'JNN0= RIVD-r Connecticut Yankee Atomic Power Company ( Site Map With Reference To Survey Unit 9537-0000 Febay2004 CO I m -m -m m m m m m m m m m m m m M 3 S 2.6 5 0 = Samle Location 8 S 7 0 10 0 1.NOWe 9 12 15 14&Connecticut Yankee Atomic Power Company 953 7-0000 Fial Status Survey Design con0
---m -m -m m m = = m m m m m m m 0.0187 0.0403 0.0174 0.0824 0.015-0.0007 0.1 0.a0-0.0029 Notes Repoed cesim-137 ncuafrtiOs mpCilg 0.0202 Bae Cas DCGL for cesum-137soil is 7.91 pCi/g 0.0085 I Connecticut Yankee Atomic Power Compa 9537-0000 Final Status Survey Cesium-131 Postink Plot Coo37 m m m M -M -M m m m m m m m m m m M 0.0139 0.0133 a0012 aol2s 0.0099 0oo.-0.01a 0.0159 0.0088 Notes Repomed coba-60 concen&tMtiosm pCIZg 0. Oh-4.0138 Bae Caw DCGL for cobalt-60id soil is 3.PC4-0.0122&Connecticut Yankee Atomic Power Company 953 7-0000 Final Status Survey Cobalt-60 Cock
-m m m --m m -m -m m m coo m mmm m m m m m M M -m m M M 0.0558.0.00885.09 0.0996 Notes Repord csium-137 conetaftions iv pcif o Base Case DCGL forcesum-137in soilis 7.91 pCi/g Connecticut Yankee Atomic Power 9537-0000 Final Status Survey Elevated, Cesium-13 7 Postinz Plot COG&
PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD Attachment 2 Sample and Statistical Data-.C--
.I PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD Attachment 2a Gamma Spectroscopy Data (89 Pages)
Analytical Data Package Prepared For Connecticut Yankee Radiochemical Analysis By STL Richland 2800 G. W. Way, Richliand Wa, 99352, (509)-375-3131.
Assigned Laboratory Code: STLR Data Package Contains 8U Pages Report No.: 24555 SDG No. Order No. Client Sample ID (Lilst Order) Lot-Sa No.Work Order Report DB ID Batch No.24642 9537-0000 ER-1 9537-0000 ER-2 9537-0000 ER-3 9537-0000 ER-4 9537-0000 ER-5 9537-0000 ER-6 9537-0000 ER-7 9537-0000-001F 9537-0000-002F 9537-0000-003F 9537-0000-003FS 9537-0000-004F 9537-000D-005FOl 9537-0000-005F02 9537-0000-006F 9537-0000-006FS 9537-0000-007F01 9537-0000-008F 9537-0000-009F 9537-0000-01OF 9537-0000-011 FOl 9537-0000-011 F02 9537-0000-012F 9537-0000-013F 9537-0000-014F01 J3L030207-22 J3L030207-23 J3L030207-24 J3L030207-25 J3L030207-26 J3L030207-27 J3L030207-28 J3L030207-1 J3L030207-2 J3L030207-3 J3L030207-4 J3L030207-5 J3L030207-6 J3L030207-7 J3L030207-8 J3L030207-9 J3L030207-1 0 J3L030207-11 J3L030207-12 J3L030207-13 J3L030207-14 J3L030207-1 5 J3L030207-16 J3L030207-17 J3L030207-1 8 J3L030207-19 F5XH21 AA F5XH31AA F5XH61 AA F5XH91AA F5XJC1AA F5XJD1AA F5XJF1AA F5XFG1AA F5XF61 AA F5XF71AA F5XF91M F5XGA1AA FSXGD1AA F5XGHI1AA F5XGK1 AA F5XGM1 AA F5XGP1AA F5XGR1AA F5XG01AA F5XG31AA F5XHC1AA F5XHD1AA F5XHE1 AA F5XHG1AA FSXHJ1AA F5XHM1AA 9F5XH21 0 9F5XH310 9F5XH610 9F5XH910 9F5XJC10 9F5XJD10 9F5XJF10 9F5XFG10 9F5XF610 9F5XF710 9F5XF910 9F5XGA10 9F5XGD10 9F5XGH10 9F5XGK10 9F5XGM10 9F5XGP10 9F5XGR10 9F5XG010 9F5XG310 9F5XHC10 9F5XHD10 9F5XHE10 9F5XHG10 9F5XHJ10 9F5XHM10 3339266 3339266 3339266 3339266 3339266 3339266 3339266 3339264 3339264 3339264 3339264 3339264 3339264 3339264 3339264 3339264 3339264 3339264 3339264 3339264 3339264 3339266 3339266 3339266 3339266 3339266 SL RIcchland rptSTLRchlntie v3.73-STL-RICHLAND
.1 Report No.: 24555 SDG No. Order No. Client Sample ID (List Order) Lot-Sa No.24642 9537-000-014F02 J3L030207 20 9537-0000-015F J3L030207-21
_. .Work Order F5XHR1 AA F5XHX1AA Report DB ID 9F5XHR10 9F5XHX1O Batch No.3339266 3339266 STL Rlchland rpISTLRlchTitle v3.73_STL-RICHLAND 2
WIMMM-D o-V .STL STL R1chland 280 George Washington Way Richfand,WA 99352 Certificate of Analysis Tel:5093753131 Fax: 509375 5590 www.stl-incxom Connecticut Yankee Atomic Power 362 Injun Hollow Road East Hampton, CT 06424 December 30,2003 Attention:
Pete Hollicbeckl Date Received in Lab : December 1. 2003 Sample Type Twenty eight (28) Soil SDG Number 24642 Project Name/Number Haddam Neck Decommissioning COC Number : 241,242,243 CASE NARRATIVE I. Introduction On December 1, 2003, twenty eight soil samples were received at the STL Richland (STLR) laboratory.
Upon receipt, the samples were assigned the STLR identification numbers as described on the cover page of the Analytical Data Package report form. The samples were assigned to Lot Number B3L030207.
II. Sample Receipt The samples were reccivcd in good condition and no anomalies were noted during check-in.[H. Analytical Results/'Methodology The analytical results for this report are presented by laboratory sample ID. Each set ordata includes sample identification information, analytical results and the appropriate associated statistical errors.The requested analysis was: Gamma Spectroscopy Gamma Spec by method RICH-RC-5017
- STL-RICHLAND
-3 Connecticut Yankee Atomic Power December 30,2003 Page 2 IV. Quality Control The analytical result for each analysis performed includes a minimum of one laboratory control sample (LCS), and one reagent blank sample analysis.
Any exceptions have been noted in the "Comments" section.QC and sample results are reported in the same units.V. Comments Gamma Spec by method RICH-RC-5017:
The following results may be false positives as the key-line activity is greater than the MDA but the identification of the radionuclide was rejected by the abundance criteria of the software.Isotopes Affected Samples Cs-134, Bi-212, Bi-214 F5XF6, FSXGD TI-208, Bi-214 F5XGK, F5XHD, F5XHIM. F5XH9 Bi-214 F5XGM Bi-212 F5XFG, F5XFG-DUP, F5XGH, F5XH3. F5XJC, F5XJF Bi-214, Ra-226 F5XG3, F5XHE Bi-212, Bi-214. Ra-226. Ac-228 F5XH6 Bi-214, Ac-228 F5XHC TI-208, Bi-214, Ra-226, Ac-228 F5XGO Cs-134. Bi-212 F5XGP TI-208 F5FX9, F5XH2 Bi-212, Bi-214, Ac-228 F5XHD-DUP TI-208, Bi-212, Bi-214, Ra-226 F5XHR Ac-228 F5XGA Bi-212, Ac-228 F5XHX Insufficient sample volume was received in order to generate a duplicate therefore a precision determination was achieved by recounting the sample on a different detector.The LCS for batch 3339266 was recounted because the results were out of limits. The recount was within acceptance limits therefore the data is accepted for reporting.
Except as noted, the LCS, batch blank, sample, and sample duplicate results are within required limits.I certify that this Certificate of Analysis is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager, or a designee as verified by the following signature.
Reviewed and approved: Theresa IL Kallsen Project Management Assistant_ STL-RICHLAND 4
Drinking Water Method Cross References DRINKING WATER ASTM METHOD CROSS REFERENCES Referenced Method lsotope(s)
STL RlIchland's SOP number EPA 901.1 Cs-134, 1-131 RICH-RC-5017 EPA 900.0 Alpha & Beta RICH-RG-5014 EPA 903.1 Ra-226 RICH-RC-5005 EPA 904.0 Ra-228 RICH-RC-5005 EPA 905.0 Sr89/90 RICH-RC-5006 ASTM D2460 Total Radium RICH-RC-5027 Standard Method 7500-U-C & ASTM D5174 Uranium RICH-RC-5058 EPA 906.0 Trtlum RICH-RC-5007 NOTE: _The Gross Alpha LCS is prepared with Arn-241 (unless otherwise specified in the caso narrathe))
The Gross Bota LCS Is prepared with Sr/Y-90 (unless otherwise specified in the case narratie)Uncertainty Estimation STL Richland has adopted the internationally accepted approach to estimating unccrtainties described in "NIST Technical Note 1297, 1994 Edition".
The approach.
CLaw of Propagation of Errors', involves the identification of all variables in an analytical method which are used to derive a result. These variables are related to the analytical result (R) by some functional relationship, R = constants
- f(x,y,z,...).
The components (x~y,z) are cvaluatcd to determine their contribution to the overall method uncertainty.
The individual component uncertainties (uj) are then combined using a statistical modcl that provides the most probable overall uncertainty value. All component uncertainties arc categorized as type A, evaluated by statistical methods, or type B. evaluated by other means. Uncertainties not included in the components.
such as sample homogencity, are combined with the component uncertainty as the square root of the sum-of-thc-squares of the individual uncertainties.
The uncertainty associated with the derived result is the combined uncertainty (u) multiplied by the coverage factor (1.2, or 3).When three or more sample replicates are used to derive the analytical result, the type A uncertainty is the standard deviation of the mean value (S/vn), where S is the standard deviation of the derived results. The type B uncertainties are all other random or non-random components that are not included in the standard deviation.
The derivation of the general 'Law of Propagation of Errors' equations and specific example are available on request.STL Richland rutGeneratlInfo v3.72-STL-RICHLAND Is Report Definitions Action Lev Batch Bias COC No Count Error (#s)Total Uncert (Ns)u,_Combined Uncertainly.(Os), Coverage Factor CRDL (RL)Lc Lot-Sample No MDCIMDA Primary Detector Ratio U-234/U-238 RstlMDC An agreed upon activity level used to trigger some action when the final result is greater than or equal to the Action Level. Often the Action Level is related to the Decision Umit.The QC preparation batch number that relates laboratory samples to QC samples that were prepared and analyzed together.Defined by the equation (Result/Expected)-l as defined by ANSI N13.30.Chain of Custody Number assigned by the Client or STL Richland.Poisson counting statistics of the gross sample count and background.
The uncertainty is absolute and in the same units as the result. For Liquid Scintillation Counting (LSC) the batch blank count is the background.
All known uncertainties associated with the preparation and analysis of the sample are propagated to give a measure of the uncertainty associated with the result, u, the combined Uncertainty.
The uncertainty is absolute and in the same units as the result.The coverage factor defines the width of the confidence interval, 1, 2 or 3 standard deviations.
Contractual Required Detection Limit as defined in the Client's Statement Of Work or STL Richland "default" nominal detection limit. Often referred to the reporting level (RL)Decision Level based on instrument background or blank, adjusted by the Efficiency, Chemical Yield. and Volume associated with the sample. The Type I error probability is approximately 5%. Lc=(1.645
" Sqrt(2*(BkgrndCnt/BkgmdCntMinySCntMin))
- (ConvFctJ(EffwYld*Abn*Vol)
- tngrFct).
For LSC methods the batch blank is used as a measure of the background variability.
Le cannot be calculated when the background count is zero.The number assigned by the LIMS software to track samples received on the same day for a given client. The sample number is a sequential number assigned to each sample in the Lot.Detection Level based on instrument background or blank, adjusted by the Efficiency, Chemical Yield, and Volume with a Type I and 11 error probability of approximately 5%. MDC = (4.65 *Sqnt((BkgmdCnt/BkgmdCncMin)YSCntMin)
+ 2.71/SCntMin)
- (ConvFctl(Eff 0 Yld
- Abn
- Vol)
- IngrFct).
For LSC methods the batch blank is used as a measure of the background variability.
The instrument identifier associated with the analysis of the sample aliquot.The U-234 result divided by the U-238 result. The U-234/U.-238 ratio for natural uranium in NIST SRM 4321 C is 1.038.Ratio of the Result to the MDC. A value greater than I may indicate activity above background at a high level of confidence.
Cuution should be used when applying this factor and it should be used in concert with the qualifiers associated with the result.Ratio or the Result to the Total Uncecrtainty.
If the uncertainty has a coverage factor of 2 a value greater than I may indicate activity above background at approximately the 955% level of confidcncc assuming a two-sided confidence interval.
Caution should be used when applying this factor and it should be used in concert with the qualifiers associated with the result.Sample Identifier used by the report system. The number is based upon the first five digits of the Work Order Number.The equation Replicate Error Ratio = (S-D)/[sqrt(TPUs 2 + TPUd 2)1 as defined by ICPT BOA where S is the original sample result, D is the result of the duplicate, TPUs is the total uncertainty of the original sample and TPUd is the total uncertainty of the duplicate sample.Sample Delivery Group Number assigned by the Client or assigned by STm Richland upon sample receipt The sum of the reported alpha spec results for tests derived from the same sample excluding duplicate result where the results are in the same units.The LIMS software assign test specific identifier.
The recovery of the tracer added to the sample such as Pu-242 used to trace a Pu-239140 method.I II I II-RstfTotUcert Report DB No RER*SDG' Sum Rpt Alpha i Spec Rst(s)'Work Order Yield l STL Rtchland rotGeneralno v3.72_ STL-RICHIAND 6
Sample Results Summary STL Richland STLR Ordered by Method, Batch No., Client Sample ID.Date: 30-Dec-03 Report No. : 24555 SDG No: 24642 Client Id Batch Work Order Parameter 3339264 RICHRC5017 9537-0000-001 F F5XFG1AA AC-228 AG-108M AM-241 81-212 Bl-214 C0060 CS-134 CS-137 EU-152 EU- 154 EU-1 55 K-40 MN-54 NB-94 PB-212 PB-214 RA-226 TL-208 9537-0000-001 F DUP F5XFG1AC AC-228 AG-i 08M AM-241 B1-212 Bl-214 CO-60 CS-134 CS-137 EU-152 EU-i154 EU-155 K-40 MN-54 N8-94 P8-212 PB-214 RA-226 MDC or Result +-Uncertainty( 2s) Oual Units Yield MDA CRDL RER2 6.07E-01-1.30E-03 2.31 E-02 1.01E+00 7.39E-01-1.19E-02 3.52E-02 8.33E-02-2.54E-02 6.08E-03 1.56E-02 1.03E401-1.96E-02-2.36E-02 6.35E-01 821E-01 7.39E-01 2.48E-01+ 1.90E-01.1.97E-02+ 5.96E-02+- 8.942-01+- 1.46E-01+- 2.29E-02+- 2.70E-02+- 3.37E-02+- 7.06E-02+- 7.64E-02-- 6.67E-02+- 1.55E+00+- 2.67E-02+- 2.42E-02 v 1.27E-01+- 1.51E-01+- 1.46E-01+- 6.95E-02 pOvg U pCVg U pC/g U pCi/g pCi/g U pCig U pCvg J pCug U pCig U pCi/g U pCVg pciug U pCi9 U pCVg pCvg pci/g pCug pCug 1.38E-01 3.42E-02 2.86E-01 8.66E-02 1.03E+00 8.01 E-01 7.68E-02 3.90E-02 1.50E-01 5.37E-02 1.90E-01 4.65E-02 3.20E-01 1.082-01 4.04E201 1.41E-01 3.70E201 1.16E-01 1.57E+01 3.68E-01 4.37E-02 6.96E-01 3.81E-02 2.85E201 6.72E-02 8.07E-02 7.68E-02 4.44E-02 7.08E-01-9.23E-03 3.02E-02 8.68E-01 8.17E-01 2.23E-02 3.01E-02 6.33E-02-5.52E-02-7.75E-02 3.27E-02 1.11 E+01 2.03E-02-6.93E-03 6.89E-01 7.96E-01 8.17E-01+- 1.97E-01 e 1.96E-02-8.92E-02.4.38E-01 4- 1.59E-01-- 2.74E-02 v 2.90E-02.- 3.80E-02+- 6.64E-02+- 9.16E-02+- 7.83E-02+- 1.74E+00+- 2.75E-02+- 2.59E-02 4- 1.33E-01+- 1.74E-01+- 1.59E-01 pCVg U pCVg U pC/g U pCug pCvg U pCVg U pCvg J pCVg U pCVg U pcig U pcug pCu/g U pCvg U pCug pcvg pCvg PCVg 1.83E-01 3.32E-02 2.86E-01 1.56E-01 1.03E+00 8.62E-01 8.75E-02 5.62E-02 1.50E-01 5.74E-02 1.90E-01 5.42E-02 3.20E-01 1.06E-01 4.04E-01 1.462-01 3.70E-01 1.34E-01 1.57E+01 5.23E-01 5.30E-02 6.96E-01 4.51 E-02 2.85E-01 6.69E-02 8.29E-02 8.76E-02 i STL Richland LrptSTLRchiSaSui mary2 V4.05 A9'RER2 -RepUcale Error Ratio = (S-Dy[sqrt(sq(TPUs)+sq(TPUd))I as defined by ICPT BOA.m I Qua3- No LI< qualifier has been assigned and the result Is below the Reporting Limit, RL (CRDL) or Report Value is Estnattd.U Qual
- Analyzed for, but the result ki less than the M&d/Mdatrotal Uncert or ga1mia scan software did not identffy the nucilde.--STL-RICHLAND7 7
Sample Results Summary STL Richland STLR Ordered by Method, Batch No., Client Sample ID.Date: 30-Dec-03 Report No.: 24555 SDG No: 24642 Client Id MDC or BSatch Work Order Parameter Result +- Uncertainty( 2s) Cual Units Yield MDA CRDL RER2 3339264 SICHRC5017 9537-0000-001F DUP-F5XFGIAC TL-208 9537-0000-002F F5XF61AA AC-228 AG-1 08M AM-241 BI-212 81-214 CO-60 CS-134 CS-137 EU-1 52 EU-1 54 EU-1 55 K-40 MN-54 NB-94 PB-212 PB-214 RA-226 TL-208 2.81E-01 +- 6.03E-02 7.84E-01-3.37E-03-5.04E-03 4.28E-01 6.82E-01 1.25E-02 3.07E-02 8.24E-02-5.46E-03-1 .98E-02 1.80E-02 9.752+00-2.25E-02-1.45E-02 5.52E-01 7.55E-01 6.82E-01 1 .55E-01+- 1.95E-01+- 2.09E-02+- 7.35E-02 4- 3.95E-01*- 1.32E-01-- 2.75E-02+ 2.79E-02 4- 3.41E-02+ 5.89E-02+- 8.44E-02+- 6.64E-02+* 1.53E+00+- 2.84E-02+- 2.12E-02-1.21E-01-1.58E-01+- 1.32E-01-5.48E-02 pCvg pC/g U pCVg U pCl/g U pCIg U pCVg U pCVg U pCVg U pCvg U pCVg U pCfg U pCVg pCVg U pCvg U pCVg pCVg pCi/g pCi~g pCl~g 4.22E-02 1.50E-01 3.56E-02 2,86E-01 1 .22E-01 1.03E+00 7.41 E-01 1.93E-01 5.28E-02 1.50E-01 5.46E-02 1.90E-01 6.60E-02 3.20E-01 1.03E-01 4.04E-01 1.49E-01 3.70E-01 1.13E-01 1.57E+01 4.20E-01 4.66E-02 6.96E-01 3.52E-02 2.85E-01 6.64E-02 7.47E-02 7.55E-02 4.44E-02 9537-0000-003F F5XF71AA AC-228 3.39E-01 +- 1.75E-01 pCi/g 1.53E-01 AG-1 08M -4.95E-03
+- 1.99E-02 U pCUg 3.39E-02 2.86E-01 AM-241 -3.44E-02
+- 1.51E-01 U pCI/g 2.49E-01 1.03E+00 BI-212 5.97E-01 + 4.38E-01 U pCVg 7.01E-01 BI-214 5.32E-01 +- 1.41E-01 pCvg 7.OOE-02 CO-60 1.33E-02 +- 2.24E-02 U pCVg 4.59E-02 1.50E-01 CS-134 1.76E-02 + 2.87E-02 U pCVg 5.43E-02 1.90E-01 CS-137 4.03E-02 +- 3.08E-02 U pCVg 5.83E-02 3.20E-01 EU-152 3.14E-02 +- 6.35E-02 U pCvg 1.15E-01 4.04E-01 EU-154 -1.14E-02
-7.46E-02 U pCvg 1.33E-01 3.70E-01 EU-155 1.77E-02 -7.68E-02 U pC/g 1.33E-01 1 .57E+01 K-40 9.68E+00 +- 1.57E+00 pCI/g 3.74E-01 MN-54 1.04E-02 +- 2.56E-02 U pCUg 4.78E-02 6.96E-01 NM94 8.01E-03 +- 2.34E-02 U pCsg 4.34E-02 2.85E-01 PE-212 5.55E-01 t- 1.12E-01 pCvg 6.29E-02 PB-214 5.92E-01 +- 1.46E-01 pCltg 7.81E-02 STL Rlchland RERZ -RepliCate Error Ratio (S-DY[qt(sqa(TUs)sq(TPUd))i as defued by ICPT BOA.rptSTLRchSasum U Quat -Analyzed for, but the result Is less than the NMddMda4to21 Uneert or gBrana scan software did not Identify the nucilde.mary2 V4.05 A97-STL-RICHLAND 8
Sample Results Summary STL Richland STLR Ordered by Method, Batch No., Client Sample ID.Date: 30-Dec-03 SDG No: 24642 Report No.: 24555-Client Id MDC or Batch Work Order Parameter Result+- Uncertainty( 2s) Oual Units Yield MDA CRDL RER2 3339264 RICHRCS017 9537-0000-003F F5XF71AA RA-226 TL-208 9537-0000-003FS F5XF91AA AC-228 AG- 108M AM-241 Bl-212 61-214 CO60 CS-134 CS-137 EU-152 EU-154 EU-1 55 K-40 MN-54 NB-94 PB-212 P8-214 RA-226 TL-208 9537-0000-004F 5.32E-01 +- 1.41E-01 1.68E-01 4- 5.97E-02 pCilg pCil/g 7.00E-02 4.05E-02 6.39E-01 1.01 E-03-2.61 E-02 6.80E-01 6.07E-01 2.07E-03 3.04E-02 3.86E-02-4.05E-03-2.30E-02 8.30E-03 1.04E+01 1.03E-02-1.00E-02 5.14E-01 6.77E-01 6.07E-01 1.72E-01+- 1.68E-01+- 1.86E-02+- 8.02E-02+ 3A8E-01-- 1.29E-01+- 2.19E-02+- 2.69E-02+- 2.66E-02+- 6.74E-02.t- 6.80E-02+- 6.60E-02+ 1.57E+00+- 2.58E-02 1.87E-02+- 1.03E-01+- 1.342-01-- 1.29E-01+- 6.57E-02 pCi/g U pC/g U pCug U pCi/g pcilg U pCI/g U pCirg U pci/g U pCilg U pcvg U pCvg.pci/g U pCVg U pCvg pCVg pCV9 pCig U pCi/g 1.24E-01 3.31E-02 2.86E-01 1.36E-01 1.03E+00 6.99E-01 7.65E-02 4.20E-02 1.50E-01 5.31 E-02 1.90E-01 5.17E-02 3.20E-01 1.13E-01 4.04E-01 1.18E-01 3.70E-01 1.12E-01 1.57E+01 3.15E-01 4.80E-02 6.96E-01 3.18E-02 2.85E-01 5.43E-02 7.07E-02 7.65E-02 7.80E-02 F5XGAIAA AC-228 5.18E-01 4- 1.81E-01 U pCVg 3.02E-01 AG-108M -4.15E-03 4- 2.12E-02 U pC[g 3.65E-02 2.86E-01 AM-241 4.84E-02 +- 5.23E-02 U pCVg 8.08E-02 1.03E+00 81-212 1.16E-01 +- 3.83E-01 U pCVg 6.90E-01 BI-214 5.23E-01 +- 1.17E-01 pCilg 7.71E-02 Co-60 1.39E-02 +- 2.21E-02 U pCi/g 4.50E-02 1.50E-01 CS-134 1.40E-02 +- 2.78E-02 U pCI/g 5.17E-02 1.90E-01 CS-137 1.87E-02 +- 2.58E-02 U pCig 4.85E-02 3.20E-01 EU-152 -6.51E-03
+- 6.56E-02 U pCVg 1.11E-01 4.04E-01 EU- 154 -1.62E-02
+- 6.44E-02 U pCig 1.16E-01 3.70E-01 EU-155 1.40E-02 +- 6.43E-02 U pC/g 1.10E-01 1.57E+01 K-40 8.64E+00 + 1.41E+00 pCVg 3.13E-01 MN-54 7.44E-03 +- 2.36E-02 U pCVg 4.35E-02 6.96E-01 NB-94 1.79E-03 + 2.18E-02 U pCVg 4.00E-02 2.85E-01 PB-212 4.98E-01 +- 1.07E-01 pCvg 6.53E-02 STL Richland RER2 -Replicate Error Ratio = (S-DY[sqrt(sq(TPU9)+sq(TPUd))J as defined by TCPT BOA.rVotT c ghsatum U Qual -Analyzed for, but the result Is lss than the Mdc/MdalTotal Uncert or gam-a scan software did not identity the nuclide.I rnary2 V4.05 A97 STL-RICHLAND 9
Sample Results Summary STL Richland STLR Ordered by Method, Batch No., Client Sample ID.Date: 30-Dec-03 Report No.: 24555 SDG No: 24642 Client Id MDC or Batch Work Order Parameter Result +-Uncertainty( 2s) Oual Units Yield MDA CROL RER2 3339264 RICHRC5017 9537-0000-004F F5XGA1M PB-214 RA-226 TL-208 6.08E-01 5.24E-01 1.71 E-01-9537-0000-005F01 F5XGD1AA AC-228 AG-1 08M AM-241 BI-212 8I-214 C0-60 CS- 134 CS-137 EU-152 EU-154 EU-155 K-40 MN-54 NB-94 PB-212 PB-214 RA-226 TL-208 6.88E-01 1 .48E-04-7.51 E-02 1.03E+00 7.72E-01 9.90E-03 9.392-02 1.50E-02 7.87E-02 2.52E-02 8.58E.02 9.68E+00-2.20E-03-.AOE-02 6.14E-01 7.44E-01 7.72E-01 2.49E-01+ 1.32E-01+- 1.17E-01+ 5.36E-02+- 2.11E-01+- 2.10E-02+- 1.62E-01+ 8.71 E-01+- 1.57E-01+- 2.46E-02+ 6.06E-02+- 2.93E-02+- 7.12E-02+- 8.16E-02+- 8.30E-02+- 1.59E+00+- 2.63E-02+- 2.18E-02 o 1.24E-01+- 1.56E-01+- 1.57E-01+- 7.02E-02 pCig pCVg pCVg pCVg U pC/g U pC/g U pCug U pCVg U pCug U pCVg U pC/g U pC'g U pCvg U pCvg pCi/g U pCug U pCig pCi/g pC/g pcUg pCi/g 1.81 E-01 3.67E-02 2.86E-01 2.63E-01 1.03E+00 8.08E-01 2.10E-01 4.89E-02 1.50E-01 6.96E-02 1.90E-01 5.34E-02 3.20E-01 1.33E-01 4.04E-01 1.53E-01 3.70E-01 1A8E-01 1.57E+01 4.28E-01 4.70E-02 6.96E-01 3.63E-02 2.85E-01 7.47E-02 8.79E-02 8.52E-02 4A2E-02 7.80E-02 7.71 E-02 3.85E-02 9537-0000-005Fo2 F5XGHlAA AC-228 5.17E-01 -1.65E-01 pCig 1.41E-01 AG-108M 2.77E-03 +- 1.79E-02 U pCIg 3.18E-02 2.86E-01 AM-241 5.81E-03 +- 5.71E-02 U pCi/g 8.18E-02 1.03E+00 BI-212 1.02E+00 +- 6.80E-01 U pC/g 7.78E-01 BI-214 5.78E-01 +- 1.37E-01 pClg 7.52E-02 C0-60 -2.75E-02
-2.02E-02 U pCvg 2.75E-02 1.50E-01 CS-134 1.37E-02 +- 2.55E-02 U pC/g 4.78E-02 1.902-01 CS-137 2.55E-02 -2.66E-02 U pCVg 5.02E-02 3.20E-01 EU-152 -7.47E-02
-6.57E-02 U pCVg 9.75E-02 4.04E-01 EU-154 4.99E-02 -- 7.12E-02 U pCvg 1AOE-01 3.70E-01 EU-155 1.14E-02 +. 6.29E-02 U pCVg 1.09E-01 1.57E+01 K-40 1.11E+01 +- 1.62E+OO pCVg 2.91E-01 MN-54 8.20E-03 -- 2.53E-02 U pCVg 4.62E-02 6.96E-01 NB-94 5.52E-03 +- 2.13E-02 U pC/g 3.91E-02 2.85E-01 STL Richland RER2 -Replicate Error Ratio = (S-D)4sqrt(sqCTPUs)+sqtlUd))I as defined by ICPI BOA.I rptSTLRchSaSum U Qual -Analyzed tor, but the result Is less than the NidchldatTotal Unced or ga=ma scan software did not identify the nuclidc.mary2 V4.05 A97~-STL-RICHLAND 1 10 Sample Results Summary STL Richland STLR Ordered by Method, Batch No., Client Sample ID.Date: 30-Dec-03 Report No.: 24555 SDG No: 24642 Client Id Batch Work Order Parameter 3339264 RICHRC5017 9537-0000-005F02 F5XGHIAA PB-212 PB214 RA-226 TL-208 9537-0000-006F F5XGK1M AC-228 AG-108M AN-241 81-212 Bl-214 CO-60 CS-1 34 CS-137 EU-152 EU-154 EU-155 K-40 MN-54 NB-94 PB-212 PB-214 RA-226 TL-208 9537-0000-006FS F5XGM1AA AC-228 AG-108M AM-241-B-212 81.214 CO-60 CS-134 CS-137 EU-152 EU-154 EU-155 K-40 MN-54 MDC or Result+-Uncertainty( 2s) Oual Units Yield MDA CRDL RER2 5.87E-O1 6.22E-01 5.78E-01 2.02E-01 6.27E-01-5.64E-04 6.74E-03 4.14E-01 4.71 E-01-2.01E-03-7.07E-03 1.74E-02 2.13E-02 9.91 E-02-7.76E-03 8.97E+00 5.26E-03 1.07E-02 5.01E-01 6.31E-01 4.71E-01 1.18E-01+- 1.17E-01+- 1.31 E-01+- 1.37E-01+- 6.00E-02+- 2.00E-01+- 1.99E-02+- 1.52E-01+- 3.87E-01+ 1.58E-01+- 2.34E-02+- 2.87E.02+- 2.87E-02+- 6.09E-02-8.63E-02 4- 7.57E-02+- 1.49E+00+- 2.70E-02+- 2.45E-02-1.19E-01+- 1.39E-01+- 1.58E-01*- 5.52E-02 pCvg pCVg pCVg pCVg pCVg U pCLg U pCVg U pCvg U pCVg U pCVg U pCVg U pCVg U pCvg U pCVg U pCI/g pCVg U pCig U pCI/g pCVg pCVg pC/g U pCVg 6.15E-02 7.54E -02 7.52E-02 3.99E-02 1.72E-01 3.49E-02 2.86E-01 2.55E-01 1.03E+00 7.48E-01 1.95E-01 4.38E-02 1.50E-01 5.04E-02 1.90E-01 5.28E.02 3.20E-01 1.11E-01 4.04E-01 1.74E-01 3.70E-01 1.29E-01 1.57E+01 4.06E-01 4.93E-02 6.96E-01 4.602-02 2.85E-01 7.57E-02 8.26E-02 8.42E-02 8.01E-02 6.06E-01-1.53E-02 4.12E-02 3.82E-01 5.51E-01-4.62E-03 5.47E-02-8.92E-03 1.94E-02 8.88E-03 4.53E-02 1.04E+01-2.69E-04+- 1.55E-01+- 1.90E-02+- 8.18E-02+- 3.65E-01+- 1.17E-O1+- 2.73E-02+- 2.85E-02+- 2.35E-02+- 6.30E-02+- 8.08E-02 4- 6.62E-02+- 1.63E+0O+- 2.83E-02 pCVg U pCVg U pCVg U pCIIg U pCIg U pCVg U pci/g U pCvg U pC/g U pCi/g U pClg pCVg U pci/g 1.43E-01 3.12E-02 1.44E-01 6.98E-01 1.83E-01 4.96E-02 5.91 E-02 4.04E-02 1.11E-01 1.A8E-01 1.15E-01 3.10E-01 5.06E-02 2.86E-01 1.03E+00 1.50E-01 1.90E-01 3.20E-01 4.04E-01 3.70E-01 1.57E+01 6.96E-01 ISiT Richland~.rptSTI-RchSaSurn mary2 V4.05 A97 RFR2 -Replicate Error Ratio = (S.D)/Ysqrt(sq(TPUs)+sq(TPL'd))I as defined by ICPT BOA.U Qu2l -Analyzed for. but the result is less than the bMdcldaRotal Uncert or garna scan software did not Identify the nuclide...J)TL-RICHLAMD1 11 Sample Results Summary STL Richland STLR Ordered by Method, Batch No., Client Sample ID.Date: 30-Dec-03 Report No.: 24555 SDG No: 24642 Client Id MDC or Batch Work Order Parameter Result+ Uncertainty( 2s) Qusl Units Yield MDA CRDL RER2 3339264 RICHRC5017 9537-0000-006FS F5XGM1AA NB-94 PB-212 PB-214 RA-226 TL-208 9537-0000-007F01 F5XGPIM AC-228 AG-1 08M AM-241 Bt-212 81-214 CO-60 CS- 134 CS-137 EU-152 EU- 154 EU-1 55 K-40 MN-54 NB-94 PB-212 PB-214 RA-226 TL-208 9537-0000-007FO2 7.03E-03 5.29E-01 5.95E-01 5.51 E-01 1.52E-01+- 2.16E-02+- 1.05E-01+- 1.23E01+- 1.17E-01+- 6.11E-02 U pCvg pCi/g pCI/g pci/g pCvg 4.07E-02 2.85E-01 8.31 E-02 6.87E-02 7.24E-02 3.90E-02 6.63E-01 3.82E-03-2.79E-02 1.04E+00 6.60E-01 1.59E202 7.44E-02 9.98E-03-4.31 E-03 2.12E-02 2.60E-02 1.03E+01-7.37E-04-1.62E-03 6.28E-01 7.31 E-01 6.61 E-01 2.19E-01+- 1.74E-01+ 1.75E-02+- 5.66E-02+- 3.16E-01+- 1.32E-01+- 2.07E-02+ 3.69E 02+- 2.55E-02+ 5.61E-02-- 7.74E-02+- 6.38E-02-- 1.50E+00 4- 2.41E-02-2.15E-02+- 1.21E-01+- 1.45E-01+- 1.32E-01+- 5.86E-02 pCi/g U pci/g U pCVg U pCVg pClg U pCVg U pCVg U pCVg U pCVg U pCVg U pCVg pClIg U pCVg U pCVg pcvg pCVg pCVg pCi/J 1.36E-01 3.12E-02 2.86E-01 7.81E-02 1.03E+00 7.09E-01 6.65E-02 4.28E-02 1.50E-01 6.07E-02 1.90E-01 4.66E-02 3.20E-01 9.78E-02 4.04E201 1.44E-01 3.702- 01 1.11 E-01 1.57E+01 2.74E-01 4.28E-02 6.96E-01 3.80E-02 2.852-01 6.30E-02 7.03E-02 6.65E-02 3.34E-02 F5XGR1AA AC-228 7.16E-01 + 2.01E-01 U pCi/g 3.52E-01 AG-108M 7.68E-03 +- 2.33E-02 U pCVg 4.14E-02 2.86E-01 AM241 1.80E-02 +- 1.70E-01 U pc/g 2.91 E-01 1.03E+00 BI-212 6.39E-01 v 4.75E-01 U pCVg 9.07E-01 81-214 8.15E-01 F 1.74E-01 pCVg 8.ooE-02 CO-60 1.99E-02 +- 3.11E-02 U pCVg 6.10E-02 1.50E-01 CS-134 2.33E-02 +- 3.46E-02 U pC/g 6.47E-02 1.90E-01 CS-137 6.25E-02 -4.61E-02 J pCVg 5.07E-02 3.20E-01 EU-152 7.20E-02 + 7.24E-02 U pCVg 1.35E-01 4.04E-01 EU-154 -2.18E-02
+- 8.18E-02 U pCVg 1.45E-01 3.70E-01 EU-1S5 -2.16E202
-8.62E-02 U pCVg 1.48E-01 1.57E+01 K-40 1.13E+01 +- 1.77E+00 pCvg 3.80E-01 STL Richland REi2 -Replicate Error Ratio = (S-D)4sqrtusqCFPUs}+s(TPUd))]
as defined by lCP SBOA.rptSTL chSaSum J Qual -No UI< qualifier has been assigned ud tOe result is below the Reporting Limit, RL (CRDL) or Report Value is Estimated.
mary2 V4.05 A97 U Qual -Analyzed ror, but the result Is less than the Mdc/Mdalotol Uncert or gamma scan software did not Identify the nucUde._.STL-RICHLAND 12 Sample Results Summary STL Richland STLR Ordered by Method, Batch No., Client Sample ID.Date: 30-Dec-03 Report No.: 24555 SDG No: 24642 Client Id MDC or Batch Work Order Parameter Result +-Uncertainty( 2s) Oual Units Yield MDA CRDL RER2 3339264 RICHRCSO17 9537-0000-007Fo2
-F5XGR1AA MN-54 NB-94 PB-212 PB-214 RA-226 TL-208 9537-0000-008F F5XGo1AA AC-228 AG-108M AM-241 B1-212 81-214 CO-60 CS-134 CS-137 EU-152 EU- 54 EU-155 K-40 MN-54 NB-94 PB-212 PB-214 RA-226 TL-208 2.39E-02-1.75E-03 7.87E-01 7.79E-01 8.1 5E-01 1.61 E-01 4.96E-01 1.34E-02 1.83E-02 3.02E-01 6.19E-Ot 9.25E-03 3.60E-02-6.84E-04 2.66E-02-1.94E-02 3.06E-02 9.87E+00 2.26E-02 2.73E-03 5.1 IE-01 6.09E-01 6.19E-01 1.84E-01+- 3.12E-02+- 2.71E-02+ 1.51E-01+- 1.72E-01+ 1.74E-01+ 6.76E-02+ 2.05E-01+- 2.07E-02-4.97E-02+- 3.99E-01 4- 1.34E-01 v 2.91E-02-2.99E-02+- 2.74E-02 4- 7.31 E-02-8.20E-02 4 6.52E-02-1 .57E-e00+ 2.61E-02-2.35E-02+- 1.12E-01-1.37E-01+- 1.34E-01+- 6.45E-02 U pCL'g U pCVg pCvg pC/g pCVg pC/g U pCig U pCVg U pCvg U pCvg U pCVg U pCVg U pCVg U pCVg U pCig U pCVg U pCvg pCVg U pCVg U pCig pC/g pCVg U pCVg U pCug 5.89E-02 6.96E-01 4.77E-02 2.85E-01 7.64E-02 8.94E-02 8.00E-02 4.92E-02 3.10E-01 3.84E-02 2.86E-01 8.102-02 1.03E+00 7.50E-01 2.02E-01 5.59E-02 1.50E-01 5.91E-02 1.90E-01 4.89E-02 3.20E-01 1.26E-01 4.04E-01 1.44E-01 3.70E-01 1.13E-01 1.57E+01 3.96E-01 5.07E-02 6.96E-01 4.26E-02 2.85E-01 6.67E-02 8.65E-02 2.02E-01 8.12E-02 9537-0000-009F F5XG31AA AC-228 5.93E-01 +- 1.60E-01 pCVg 1.52E-01 AG-108M 1.41E-04 + 1.73E202 U pC/g 3.02E-02 2.E6E-01 AM-241 1.61E-02 +- 7.19E-02 U pCVg 1.20E-01 1.03E+00 81-212 6.33E-01 +- 3.75E-01 U pCLg 7.27E-01 Bl-214 5.80E-01 +- 1.8E-01 U pCVg 1.79E-01 C0-60 -1.38E-02 4- 2.71E-02 U pCvg 4.62E-02 1.50E-01 CS-134 1.77E-02 +- 2.59E-02 U pC/g .4.95E-02 1.90E-01 CS-137 2.02E-02 +- 2.55E-02 U pCVg 4.78E-02 3.20E-01 EU-152 4.08E-02 +- 6.12E-02 U pCVg 1.08E-01 4.04E-01 EU-154 2.71E-03 +- 7.70E-02 U pC0g 1.41E-01 3.70E-01 EU-155 4.71E-02 +- 5.95E-02 U pCilg 1.04E-01 1.57E+01 STL Richland RER2
- Replicate Error Ratio = (S-D)lsqrt(sq(TPUs)-sq(TPUd))J as defined by ICPT BOA.rptSTLRchSaSum U Qual -Analyzed for, but the result Is Icss than tbe MdctMdatTotal Uncert or gamma scan soflware did not Identify the nuclide.mary2 V4.05 A97-STL-RICHLAND 13 Sample Results Summary STL Richland STLR Ordered by Method, Batch No., Client Sample ID.Date: 30-Dec-03 Report No.: 24555 SDG No: 24642 Client Id Batch Work Order Parameter 3339264 RICHRCso17 9537-0000-009F F5XG31M K-40 MN-54 NB-94 PB-212 P8-214 RA-226 TL-208 9537-0000-01 OF F5XHCIAA AC-228 AG-1 08M AM-241 Bl-212 81-214 CO-60 CS- 34 CS-137 EU-152 EU-1 54 EU-155 K-40 MN-s4 NB-94 PB-212 PB-214 RA-226 TL-208 3339268 RICHRC5017 9537-0000 ER-1 MDC or Result.-Uncertainty( 2s) Qual Units Yield MDA CRDL RER2 1.03E+01 1.13E-02-2.74E-03 5.05E-01 6.56E-01 5.80E-01 1 .92E-01-- 1.60E+00+- 2.38E-02+- 2.07E-02+- 1.16E-01+- 1.44E-01+- 1.18E-01+- 5.78E-02 PCU5 U pCVg U pC/g pC~g pO~g U pCVg pCVg 3.07E-01 4.47E-02 6.96E-01 3.68E-02 2.85E-01 6.97E-02 6.85E-02 1.79E-01 3.66E-02 5.54E-01-3.64E-03-1.24E-02 3.52E-01 5.32E-01 8.77E-03 2.101-02-2.90E-03 4.53E-02 1.80E-02 3.65E-02 9.21 E+00 1.81E-02-4.37E-03 4.86E-01 5.21 E-01 5.33E -01 1.63E-01+- 1.96E-01-- 1.75E-02 4- 8.57E-02+- 3.52E-01+- 1.28E-01 2.20E-02-2.95E-02-2.60E-02 4- 6.51E-02 4- 7.31E-02-- 6.72E-02-- 1.48E+00+- 2.54E-02+ 2.28E-02+ 1.03E-01+- 1.34E-01+- 1.28E-01+- 4.76E-02 U pCilg U pCVg U pCI/g U pCVg U pCVg U pCVg U pCVg U PCvg U pCVg U pCLg U pCVg pCVg U pCVg U pC/g pCig pCl/g pCVg pCilg 2.91E-01 3.06E-02 1.A4E-01 6.77E-01 1.88E-01 4.40E-02 5.55E-02 4.602-02 1.14E-01 1.39E-01 1.19E-01 2.86E-01 1.03E+00 1.50E-01 1.90E-01 3.20E-01 4.04E-01 3.70E-01 1.57E201 4.40E-01 4.83E-02 6.96E-01 4.06E-02 2.85E-01 8.35E-02 6.73E-02 7.11 E-02 3.71 E-02 F5XH21M AC-228 5.54E-01 -2.10E-01 pCVg 1.59E-01 AG-108M 8.72E-03 +- 2.06E-02 U pC/g 3.71E-02 2.862-01 AM241 1.982-02 +- 628E-02 U pCVg 9.51E-02 1.03E+00 Bl-212 1.54E+00 +- 5.61E-01 U pCVg 8.95E-01 B-214 8.16E-01 + 1.70-E01 pCVg 7.48E-02 CO-60 -3.56E-03
-2.55E-02 U pCVg 4.70E-02 1.50E-01 CS-134 3.48E-02 +- 3.50E-02 U pClvg 6.64E-02 1.902-01 CS-137 5.58E-02 +- 3.19E-02 U pCVg 6.24E-02 3.20E-01 EU-152 2.55E-02 +- 7.23E-02 U pCVg 1.29E-01 4.04E-01 STL Richland RER2
- Replicate Error Ratlo = (S-D)4sqrt(sq(TPUs)+sq(]TUd))I as dtfined by ICPFT BOA.rntSTl 0ch-aniSm U Qual -Analyzed for, but the result Is less than the Md&AbdarTotal UDcert or ganmia scan software did not identify the nuclide.mary2 V4.05 A97-'STL-RICKLAND 1 14 Sample Results Summary STL Richland STLR Ordered by Method, Batch No., Cliont Sample ID.Date: 30-Dec-03 SDG No: 24642 Report No.: 24555-Client Id MDC or Batch Work Order Parameter Result +- Uncertainty( 2s) Qual Units Yield MDA CRDL RER2 9537-0000 ER-1 F5XH21AA EU-154 EU-155 K-40 MN-54 NB-94 PB-212 PB-214 RA-226 TL-208 9537-0000 ER-2 F5XH31AA AC-228 AG-1 OBM AM-241 Bl-212 BI-214 CO-60 CS-134 CS-137 EU-152 EU-154 EU-1 55 K-40 MN-54 NB-94 PB-212 PB-214 RA-226 TL-208-2.11 E-02 +- 7.86E-02 6.32E-02 -7.33E-02 1.23E+01 +- 1.81E+00-2.14E-02
-- 2.72E-02-9.42E-03
+- 2.50E-02 6.64E-01 -- 1.45E-01 7.64E-01 +- 1.56E-01 8.16E-01 +- 1.70E-01 2.33E-01 +- 7.09E-02 8.06E-01 4- 2.12E-01 4.46E-04 + 2.13E-02-4.97E-03 4- 9.32E.02 1.31 E+00 -4.60E-01 6.53E-01 -1.462-01 6.30E-03 + 2.56E-02 2.99E-02 4- 2.99E-02 8.S5E-03 +- 2.71E-02 2.56E-02 .- 6.77E-02-4.46E-02
+- 6.92E-02 4.29E202 +- 7.33E-02 1.01E+01 +- 1.59E+00-8.56E-03
- 2.52E-02-8.51 E-03 +- 2.39E-02 6.60E-01 +- 1.26E-01 8.10E-01 i- 1.54E-01 6.53E-01 +- 1.46E-01 1.94E-01 +- 6.60E-02 U pCVg U pCVg pCig U pCi!g U pCig pCVg pCi~g pCi/g pC~g pCilg U pCi~g U pCilg U pCi/g pC~g U pCi/g U pCi/g U pC~g U pCi/g U pC~g U pC~g pC~g U pC~g U pCVg pC~g pC~g PCUg pC~g 1.41 E-01 3.70E-01 1.30E-01 1.57E+01 4AOE-01 4.51 E-02 6.96E-01 4.35E-02 2.85E-01 8.64E-02 8.00-E02 7.48E-02 4.64E-02 1.52E-01 3.77E-02 2.86E-01 1.57E-01 1.03E+00 8.53E-01 7.89E-02 4.94E-02 1.50E-01 5.80E-02 1.90E-01 4.98E-02 320E-01 1.20E-01 4.04E-01 1.172-01 3.70E-01 1.30E-01 1.57E+01 3.84E-01 4.31 E-02 6.96E-01 4.19E-02 2.85E-01 6.36E-02 8.02E-02 7.89E-02 4.36E-02 9537-0000 ER-3 F5XH61AM AC-228 9.03E-01 +- 2.04E-01 U pCVg 3.54E-01 AG-108M -6.83E-03
+- 2.22E-02 U pC/g 3.73E-02 2.86E-01 AM-241 7.57E-02 +- 8.052-02 U pCVg 1.45E-01 1.03E+00 81-212 1.14E+00 +- 5.28E-01 U pCVg 8.83E-01 81-214 6.47E-01 +- .35E-01 U pCVg 2.03E-01 CO-60 2.27E-03 +- 3.25E-02 U pCVg 5.96E-02 1.50E-01 CS.134 2.10E-02 +- 3.25E-02 U pCVg 6.13E-02 1.90E-01 CS-137 6.99E-02 +- 4.05E-02 J pCI/g 4.92E-02 3.20E-01 STL Richland RER2 .Replicate Error Ratio = (S-D)[sqrt(sq(TPUs)+sq(TPUd))I as defined by [CPT BOA.L..i rptSTLRchSaSum J Qual -No UL< quallfer has been assigned and tbe rcsult Is below the Reporting Linit, RL (CRDL) or Report Value is Estimated.
pary2 V4.05 A97 U Qual -Analyzed for, but the result Is less than the Mldchldarrotal Uaccrt or gamma scan soflware did not Identity the nucildc..-S'TL-RICHLAND 15 Sample Results Summary STL Richland STLR Ordered by Method, Batch No., Client Sample ID.Date: 30-Dec-03 Report No.: 24555 SDG No: 24642 Client Id MDC or Batch Work Order Parameter Result +-Uncertainty( 2s) lual Units Yield MOA CROL RER2 3339266 RICHRCS017 9537-0000 ER-3 F5XH61M EU-152 EU-154 EU-1 55 K-40 MN-54 NB-94 P8-212 P8-214 RA-226 TL-208-2.81 E-02-9.44E-02 7.40E-02 1.05E+01-6.30E-03-5.71 E-03 6.57E-01 8.22E-01 6.47E-01 2.15E-01+- 7.09E-02+- 8.26E-02+- 7.05E-02+- 1.67E+00+- 2.86E-02+- 2.32E-02+- 1.34E-01+- 1.81E-01+- 1.35E-01+- 5.65E-02 U pC/g U pCvg U pC/g pCIg U pCVg U pCVg pCVg pCVg U pCVg pCVg 1.21E-01 4.04E-01 1.28E-01 3.70E-01 1.24E-01 1.57E+01 4.22E-01 5.02E-02 6.96E-01 4.09E-02 2.85E-01 6.75E-02 8.57E-02 2.03E-01 4.33E-02 9537-0000 ER-4 F5XH91AA I I C E E I.F F F 9537-0000 ER-5 kC-228 kG-108M kM-241 31-212 31-214 110-60'S-134'OS.137 WU-152-U-154 EU-155 C-40 AN-54 4B-94 18-21 2'8-214 IA-226 1-208 6.00E-01 6.48E-03 7.77E-02 7.18E-01 4.32E-01 1.93E-02 2.13E-02 2.23E-02-1.44E-02 3.71 E-02 4.98E-02 9.57E+oo-1.12E-04-7.24E-03 6.13E-01 5.91E-0 1 4.32E-01 1.71 E-01+- 1.88E-01+- 1.93E-02.- 1.42E-01+- 4.22E-01+- 1.23E-01-2.81E-02-3.00E-02 4- 2.73E-02-6.57E-02+ 7.90E-02+- 7.01E-02+- 1.57E+Oo+- 2.83E-02+ 2.01E-02+ 1.28E-01+ 1.60E-01+- 1.23E-01+- 6.14E-02 pCvg U pCVg U pCVg U. pCVg U pCvg U pCvg U pCVg U pCVg U pCVg U pCvg U pCUg pCVg U pCVg U pCVg pCvg pCVg pCVg U pCVg 1.57E-01 3.48E-02 2.86E-01 2.50E -01 1.03E+00 8.24E-01 1.83E-01 5.59E-02 1.50E-01 5.68E-02 1.90E-01 5.11 E-02 3.20E-01 1.14E-01 4.04E-01 1.53E-01 3.70E-01 127E-01 1.57E+01 4.47E-01 5.02E-02 6.96E-01 3.47E-02 2.85E-01 6.89E-02 8.27E-02 8.69E-02 8.65E-02 F5XJC1M AC-228 9.83E-01 +- 2.19E-01 pCig 1.83E-01 AG-108M 6.86E-03 +- 2.35E-02 U pCVg 423E-02 2.86E-01 AM241 -1.41E-03
+ 5.79E-02 U pCVg 9.74E-02 1.03E+00 Bi-212 1.40E+00 .5.84E-01 U pCVg 9.68E-01 Bl-214 7.57E-01 4- 1.74E-01 pCVg 9.06E-02 CO-60 -1.59E-02 4- 2.87E-02 U pCig 4.94E-02 1.50E-01 CS-134 5.24E-02 4- 3.63E-02 U pCVg 7.15E-02 1.90E-01 STL Richland RER2 -Rep~cats Error Ratio = IS-D)4sqrt(sq(TPUs)+sq(TPUd))]
as defined by ICPr BOA.L rptSTLRchSaSum U Qual -Analyzed for, but thc result i less than the MdcTidalTotaI Uncert or gamrn scan software did not identify the nudide.mary2 V4.05 A97...3TL- RICHLAND 1 16 Sample Results Summary STL Richland STLR Ordered by Method, Batch No., Client Sample ID.Date: 30-Dec-03 Report No.: 24555 SDG No: 24642 Client Id Batch Work Order Pi 3339266 RICHRC5017 9537-0000 ER-5 F5XJC1M CS-137 EU-1 52 EU-154 EU-155 K-40 MN-54 NB-94 PB-212 PB-214 RA-226 TL-208 9537-0000 ER-6 F5XJD1AA AC-228 AG-i 081 AM241 Bl-212 B-214 CO-60 CS-134 CS-1 37 EU-152 EU- 154 EU-1 55 K-40 MN-54 NB-94 PB-212 PB-214 RA-226 TL-208 9537-0000 ER-7 F5XJF1M AC-228 MDC or irameter Result+-Uncertalnty( 2s) Qual Units Yield MDA CRDL RER2 9.96E-02-6.10E-02 1 .93E-02 8.54E-02 1.01 E+01 4.68E-03-9.29E-03 8.26E-01 7.21 E-01 7.58E-01 2.52E-01 IM 6.42E-01-3.23E-03-4.97E-02 5.14E-01 6.33E-01 1.52E-03 5.68E-02 2.44E-02-2.73E-02 1.65E-02 1.38E-01 9.26E+00 1.00E-02-8.78E-03 5.93E-01 7.95E-01 6.33E-01 2.22E-01+- 4.03E-02+- 8.40E-02+- 9.52E-02+- 7.72E-02+ 1.67E+00+- 3.32E-02+- 2.54E-02+- 1.59E-01+- 1.81E-01 4 1.74E-01+- 6.34E-02+- 2.01E-01+- 2.07E-02 4- 1.58E-01-4.10E-01-1.27E-01+- 2.77E-02+- 3.18E-02+- 2.85E-02+- 6.66E-02+- 7.23E-02+ 8.13E-02 4- 1.4sE+00-3.01E-02+ 2.34E-02+- 1.28E-01+- 1.59E-01+- 1.27E-01+- 5.81E-02+- 1.86E-01+- 2.33E-02+- 5.72E-02+- 4.73E-01-1.72E-01+- 2.48E-02 U pCvg U pCvg U pCi/g U pci/g pCI/g U pCis U pcilg pCVg pCVg pC~g pCi/g pCi/g U pCVg U pCi/g U pCI/g pCi/g U pCVg U pC/g U pCi/g U pCVg U pcVg U pCVg pCVg U pCVg U pCVg pcvg pcvg pCVg pCi/g 7.92E-02 3.20E-01 1.29E-01 4.04E-01 1.75E-01 3.70E-01 1.35E-01 1.57E+01 4.87E-01 5.96E-02 6.96E-01 4.36E-02 2.85E-01 7.11E-02 1.00E-01 9.06E-02 4.72E-02 1.552-01 3.56E-02 2.86E-01 2.65E-01 1.03E+00 7.91E-01 8.57E-02 5.13E-02 1.50E-01 6.40E-02 1.90E-01 5.33E-02 3.20E-01 1.1 4E-01 4.04E-01 1.38E-01 3.70E-01 1A9E-01 1.57E+01 3.49E-01 5.49E-2 6.96E-01 3.99E-02 2.85E-01 727E-02 8.58E-02 8.57E-02 4.36E-02 I AG-A 08M AM241 BI-212 81-214 C0-60 7.04E-01-1.08E-02 2.47E-02 1.03E+00 6.40E-01 8.18E-03 pC/g U pCVg U pCVg U pCi/g pCig U pCig 1.69E-01 3.95E-02 9.31E-02 9.40E-01 926E-02 4.94E-02 2.86E-01 1.03E+00 1.50E-01 STL Richland RER2 -Replicaic Error Ratio = (S.D)/sqrl(sq(TPUs)+sqC(TUd))]
as defined by lCPT BOA.-rptSTLRchSaSum U Qu2l -Analyzed for, but the result is less than the MdclMdalTotal Unccrt or gamma scan software did not Identify the nuclide.mary2 V4.05 A97-JSTL-RICHLAND 1 17 Sample Results Summary STL Richland STLR Ordered by Method, Batch No., Client Sample ID.Date: 30-Dec-03 Report No.: 24555 SDG No: 24642 Client Id Batch 'Work Order Parameter 3339266 RICHRC5017 9537-0000 ER-7-F5XJF1AA CS-134 CS-137 EU-152 EU-154 EU-155 K-40 MN-54 NB-94 PB-212 PB-214 RA-226 TL-208 9537-0000-011 F01 F5XHD1AA AC-228 AG-108M AM-241 81-212 81-214 CO-60 CS-134 CS-137 EU- 152 EU-154 EU-155 K-40 MN-54 NB-94 PB-212 P8-214 RA-226 TL-208 9537-0000-011FOl DUP F5XHD1AC AC-228 AG-108M AM-241_1-212 Bl-214 MOC or Result +-Uncertainty( 2s) Oual Units Yield MDA CRDL RER2 3.21E-02 3.42E-02 2.70E-02 2.97E-02-1.38E-02 1.09E+01-1.67E-03 1.78E-02 7.21 E-01 6.53E-01 6.40E-011 2.49E-01 5.79E-01 7.43E-03-6.98E-02 4.34E-01 4.88E-01-1.04E-02 2.54E-02 3.38E-02-2.19E-02 4.79E-02 2.82E-02 1 .OSE+01 1.41 E-02 1.43E-02 5.012-01 5.54E-01 4.88E-01 2.04E-01 5.28E-01 1.91E-03 4.71 E-02 7.73E-01 4.29E-01+- 3.26E-02+- 3.12E-02* 7.40E-02+- 7.63E-02+- 6.91E-02+- 1.71 E+00+- 3.05E-02+- 2.49E-02+- 1 A2E-01+- 1.55E-01+- 1.72E-01+- 7.11E-02+- 1.56E-01+- 1.95E-02+- 8.89E-02+- 3.55E-01+- 1.21E-01+- 1.92E-02+- 2.69E-02+- 2.92E-02+- 6.89E-02-7.30E-02+- 6.88E-02+- 1.67E+00+- 2.69E-02+- 2.33E-02+- 1.03E-01+ 1.36E-01+- 1.21E-01+- 5.48E-02+- 1.78E-01+- 2.12E-02 4- 7.38E-02.4.52E-01-1.14E-01 U pCVg U pCVg U pCvg U pCvg U pC/g pCig U pCVg U pCVg pC~g pCl/g pCVg pCi/g pC/g U pC~g U pCi/g U pC~g U pCi/g U pCitg U pCilg U pC~g U pCilg U pCVg U pCVg pCVg U pCVg U pCvg pC~g U pCVg U pCVg U pCvg U pCVg U pcvg U pCVg u pcug 6.31 E-02 6.00E-02 1.34E-01 1.A8E-01 1.17E-01 4.48E-01 5.39E-02 4.80E-02 7.26E-02 8.22E-02 9.26E-02 5.04E-02 1.90E-01 3.20E-01 4.04E-01 3.70E-01 1.57E+01 6.96E-01 2.85E-01 1.38E-01 3.57E-02 2.86E-01 1A4E-01 1.032+00 6.97E-01 1.79E-01 3.32E-02 1.50E-01 5.27E-02 1.90E-01 5.62E-02 3.20E-01 1.16E-01 4.04E-01 1.47E-01 3.70E-01 1.22E-01 1.57E+01 4.50E-01 5.03E-02 6.96E-01 4.52E-02 2.85E-01 5.86E-02 7.77E-02 7.78E-02 8.40E-02 2.88E-01 3.69E-02 2.86E-01 1.25E-01 1.03E+00 7.44E-01 1.76E-01! STL Richland RER2 -Replicate Error Ratio = (S-DYsqrt(sq(rPUs)+sqCTPUd))]
as defined by ICPT BOA.-LrptSTLRchSaSum U Qual -Analyzed for, but the result Is less than the NIdc/l¶.darotal Uncert or gammn scan software did not Identity the nucUde.mary2 V4.05 A97 L.5-TL -RICHLAND 1 18 Sample Results Summary STL Richiand STLR Ordered by Method, Batch No., Client Samplo ID.Date: 30-Dec-03 Report No.: 24555 SDG No: 24642 Cllont Id Batch Work Order Parameter 3339266 RICHRC5017 9537-0000-01 1F01 DUP F5XHD1AC CO60 CS-1 34 CS-137 EU-152 EU-154 EU-155 K40 MN-54 NB-94 PB-212 PB-214 RA-226 TL-208 9537-0000-01 1 F02 F5XHE1M AC-228 AG-108M AM-241 BI-212 Bl-214 CO-60 CS-134 CS-137 EU-152 EU-154 EU- 155 K-40 MN-54 NB-94 PB-212 PB-214 RA-226 1L 208 MDC or Result+-Uncertainty( 2s) Oual Units Yield MDA CRDL RER2-8.01 E-03 4.44E-02 3.10E-02-4.07E-02 4.44E-02 5.46E-02 8.12E+00-124E-02-521 E-03 4.84E-01 6.29E-01 4.29E-01 1.52E-01+- 2.71E-02+- 3.06E-02+- 2.67E-02+- 6.57E-02+- 9.03E-02+ 6.19E-02-1.42E+O0+- 2.88E-02+- 2.28E-02+- 1.07E-01+ 1.38E-01+- 1.14E-01+- 5.42E-02 U pCVg U pCvg U pCig U pCVg U pCvg U pCVg pCig U pCVg U pCVg pCi/g pCvg pCvg pCi/g 4.80E-02 6.07E-02 5.15E-02 1.1 02-01 1.72E-01 1.08E-01 2.30E-01 4.93E-02 4.02E-02 6.17E-02 8.28E-02 825E-02 4.14E-02 1.50E-01 1.90E-01 3.20E-01 4.04E-01 3.70E-01 1.57E+01 6.96E-01 2.85E-01 5.91E-01 1.22E-02-2.65E-02 7.93E-01 4.81 2-01 3.03E-03 5.16E-02 1.98E-02-7.11 E-02-3.01E-02 3.46E-02 1.02E+01-6.50E-03 1.50E-02 5.31E-01 5.73E-01 4.81 E-01 1.61 E-01+- 2.06E-01 2.18E-02-1.44E-01+- 4.62E-01+ 1.34E-01 2.67E-02+- 3.35E-02 2.95E-02+- 7.21 E-02+- 1.05E-01+- 8.04E-02+- 1.67E+00+- 2.74E-02+- 2.51E-02+- 1.18E-01+- 1.31 E-01+- 1.34E-01+- 5.65E-02 pCI/g U pCI/g U pCvg U pClg U pClg U pCig U pCVg U pCi/g U pCIg U pCVg L pCVg pCvg U pCVg U pCVg pCvg pCIg U pCVg pCVg 1.61E-01 4.00E-02 2.86E-01 2.44E-01 1.03E+00 9.09E-01 2.02E-01 5.08E-02 1.50E-01 6.74E-02 1.90E-01 5.49E-02 3.20E-01 1.1 7E-O1 4.04E-01 1.84E-01 3.70E-01 1.43E-01 1.57E+01 4.76E-01 4.78E-02 6.96E-01 4.80E-02 2.85E-01 8.60E-02 8.05E-02 2.02E-01 4.65E-02' ' 9537-0000-012F F5XHG1AA AC-228 7.37E-01 +- 2.24E-01 pCfg 1.62E-01 AG-108M -1.57E-02
+- 2.36E-02 U pCIg 3.93E-02 2.86E-01 AM241 2.54E-03 +- 5.95E-02 U pCi/g 8.88E-02 1.03E+00 81-212 7.65E-01 .4.68E-01 U pCVg 9.17E-01 STL Rlchland RER2 -Repllcate Error Rtlo =(S-D)[sqrt(sq(TPUs)-sq(TPUd))J RS detined by ICPT BOA.-rptSTLRchSaSum U Qual -Analyzed for, but the result is less than the Mdcl1dalTotal Uncert or gamma scan software did not Identify the nuclide.mary2V4.05 A97 STL-RICHLAND 19 Sample Results Summary STL Richland STLR Ordered by Method, Batch No., Client Sample ID.Date: 30-Dec-03 Report No. :24555 SDG No: 24642 Client Id MDC or Batch Wbrk Order Parameter Result+-Uncertainty( 2s) Oual Units Yield MDA CRDL RER2 3339266 RICHRC5017 9537-0000-012F
-F5XHG1AA Bl C(%< C'El El Et K-M NI pE PE R)TI 9537-0000-013F I F5XHJ1AA A(-214:)-60 S-134 3-137 J-152 J-154 J-155 40 N-54 3-94 3-212 3-214 t-226 L-208 6.48E-01-1.22E-02 3.60E-02 8.50E-03 1.20E-02 3.65E-02 3.84E-02 1.06E+01-1.75E-03 2.10E-02 6.55E-01 7.35E-0t 6.48E-01 2.64E-01 C-228 AG- 108M AM-241 Bt-212 Bl-214 CO-60 CS-134 CS-137 EU- 152 EU-154 EU-155 K-40 MN-54 NB-94 PB-212 PB-214 RA-226 TL-208 7.10E-01 4A9E-03-2.77E-02 7.58E-01 5.99E-01 1.04E-02 1.04E-02 2.64E-02 1.08E-02 4.39E-02 6.87E-03 1.19E+01 5.842-03 5.212E03 6.69E-01 6.65E-01 5.992-01 2.33E-01+- 1.73E-01+- 2.68E-02+ 3.35E-02-3.24E-02 t- 7.97E-02-8.24E-02-- 7.26E-02+- 1.75E+00+- 2.98E-02+- 2.36E-02+- 1.34E-01 e 1.63E-01+1 1.73E-01+ 6.44E-02+ 1.84E-01+- 1.95E-02+ 5.36E-02+- 4.10E-01+ 1.26E-01+- 2.71E-02+- 3.08E-02+- 2.80E-02+- 6.80E-02 i- 7.83E-02+- 6.89E-02+- 1.78E+00+ 2.64E-02+- 2.27E-02+- 1.34E-01 j 1.48E-01+ 1.26E-01+- 5.03E-02 pCi/g U pCVg U pCVg U pCvg U pCIfg U pCvg U pCig pC/g U pCi~g U pCig pC'Ug pCi/g pCVg pci/g pClg U pCl/g U pCi9g U pCVg pCOg U pCVg U pcig U pCVg U pCVg U pCVg U pCVg pCVg U pCvg U pCIg pClg pCilg pC~g pCVg 1.57E-01 3.48E-02 2.86E-01 8.77E-02 1.03E+00 8.11E-01 7.552-02 5.30E-02 1.50E-01 5.62E-02 1.90E-01 5.33E-02 3.20E-01 1.20E-01 4.04E-01 1.55E-01 3.70E-01 1.19E-01 1.57E+01 5.22E-01 4.91 E-02 6.96E-01 4.26E-02 2.85E-01 8.56E-02 8.41E-02 7.55E-02 4.68E-02 9.01E-02 4.72E-02 1.50E-01 6.54E-02 1.90E-01 5.90E-02 3.20E-01 1.38E-01 4.04E-01 1.60E-01 3.70E-01 1 2BE-01 1.57E+01 4.40E-01 5.28E-02 6.96E-01 4.71E-02 2.852-01 7.76E-02 9.93E-02 9.02E-02 4.93E-02 9537-0000-014F01 F5XHM1AA AC-228 6.33E-01 +- 2.09E-01 pC/g 1.55E-01 AG-108M 1.32E-03 +- 1.86E.02 U pC/g 3.34E-02 2.86E-01 AM-241 1.37E-02 +- 8.78E-02 U pCVg 1.49E-01 1.03E+00 STL Rlchland RER2 -Replicate Error Ratio = (S-D)i[sqrt(sq(TPUs)+sq(TPUd))1 as defined by ICPr BOA.* rptSTLRchSaSum U Qual -Analyzed for, but the rsult Is less than the MdcMdarrotal Uncert or gamma scan software did not Identify the nucilde.mary2 V4.05 A97_ STL-RICHLAND 20 Sample Results Summary STL Richland STLR Ordered by Method, Batch No., Client Sample ID.Date: 30-Dec-03 Report No.: 24555 SDG No: 24642 Client Id MDC or Batch WorK(Order Parameter Result -Uncertalnty( 2s) Qual Units Yield MDA CROL RER2 3339266 RICHRC5017 9537-0000-014F01 FSXHM1M Bi-212 81-214 CO-60 CS-1 34 CS-137 EU-152 EU-154 EU-155 K-40 MN-54 NB-94 PB-212 P8-214 RA-226 TL-208 9537-0000-014Fo2 F5XHR1AA AC-228 AG-108M AM-241 81-212 81-214 CO-60 CS-134 CS-1 37 EU-1 52 EU-1 54 EU-155 K-40 MN-54 NS-94 PB-212 PB-214 RA-226 TL-208 4.42E-01 4.96E-01 7.1 2E-03 4.72E-02 6.40E-02-2.89E-02-3.59E-02 4.05E-02 1 .02E+01 4.1 8E-03 1.09E-02 7.1 1E-01 6.42E-01 4.96E-01 1.79E-01 4.67E-01 5.29E-03 9.17E-02 1.56E+00 5.40E-01-1.65E-02 3.1 OE-02 2.70E.02-1.68E-02-2.99E.02 2.20E-02 9.41 E+00 9.69E-03-4.79E-04 5.21E-01 7.14E-01 5.40E-01 1 .93E-01+ 3.85E-01+- 1.38E-01+- 2.48E-02+- 2.90E-02+- 4.76E-02+- 6.47E-02+- 7.34E-02+- 7.21E-02+- 1.63E+00+- 2.92E-02+- 2.22E-02+- 1.34E-01+- 1.33E-01+ 1.38E-01+- 525E-02+- 2.OOE-01-1.96E-02+- 135E-01+- 6.65E-01+- 1.21E-01 t- 2.50E-02 t- 2.68E-02+- 2.93E-02.- 6.21E-02+- 8.07E-02+- 7.42E-02+- 1.47E+00 4- 2.45E-02 4- 2.09E-02+- 1.21E-01+- 1.30E-01+- 1.21E-01+- 6.07E-02 U pCVg U pCfg U pCVg U pCvg J pci/g U pcvg U pCVg U pCvg pCvg U pCVg U pCVg pCVg pCVg pCL'g U pC/g pCvg U pCVg U pCVg U pCVg U pCig U pCi/g U pCVg u pcvg U pCVg U pCVg U pCVg U pCVg pCi/g U pCVg U pCVg pC~g pCi/g U pC~g U pCVg 7.43E-01 1.87E-01 4.84E-02 1.50E-01 5.88E-02 1.90E-01 4.64E-02 3.20E-01 1.08E-01 4.04E-01 1 .27E-0 3.70E-01 1.28E-01 1.57E+01 4.36E-01 5.22E-02 6.96E-01 4.282-02 2.85E-01 6.27E-02 7.18E-02 8.27E-02 8.03E-02 1.59E-01 3A8E-02 2.86E-01 2.40E-01 1.032+00 8.33E-01 1.77E-01 4.16E-02 1.502-01 5.31E-02 1.90E-01 5.41 E-02 3.20E-01 1.07E-01 4.04E-01 1.40E-01 3.70E2-1 1.31E-01 1.57E+01 3.32E-01 4.55E-02 6.962-01 3.74E-02 2.85E-01 8.15E-02 7.64E-02 1.77E-01 8.42E-02 I 9537-0000-015F F5XHX1AA AC-228 6.72E-01 .- 2.01E-01 U pCvg 3.28E-01 AG-108M 7.33E-03 +- 1.97E-02 U pC/g 3.60E-02 2.86E-01 , STL Rlchland RER2 -Replicate Error Ratio =(S-D)/Tsqrt(sq(TPUs)sq(PUd)]
as derred by ICPT BOA.i rtSTRSSUm Qual -No VI< qualifier has been assigned and the result Is below the Reporting Limit, RL (CRDL) or Report Value Is Estiznated.
_ ary2 V4.05 hAS U Qual -Analyzed for, but the result Is less than the MdclMdarotal Uncert or gamma scan software did not Identify the nuclide.STL-RICHLAND 21 Sample Results Summary STL Richland STLR Ordered by Method, Batch No., Client Sample ID.Date: 30-Dec-03 Report No. : 24555 SDG No: 24642 Client Id MDC or Batch WorkOrder Parameter Reault+-Uncertalnty( 2s) Qual Units Yield MDA CRDL RER2 3339266 RICHRCS017 9537-0000-015F F5XHX1AA AM-241 BI-212 BI-214 CO-60 CS-134 CS-137 EUt-152 EU-1 54 EU-155 K-40 MN-54 NB-94 PB-212 PB-214 RA-226 TL-208 No. of Results: 540 6.43E.03 1.39E+0O 5.35E-01-7.25E-03 5.00E-02 2.34E-02 1.12E-02-9.68E-03-1.77E-02 8.95E+00-4.73E-03-1.38E-02 5.61 E-01 6.29E-01 5.35E-01 2.55E-01+- 5.16E-02+- 4.29E-01 4- 1.28E-01+- 2.40E-02+- 3.32E-02+- 2.99E-02+- 6.71E-02+- 7.27E-02+- 6.59E-02+- 1.48E+00+- 2.60E-02+- 2.26E-02+- 120E-01+- 1.50E-01+- 1.28E-01+- 5.52E-02 U pCVg U pCVg pCVg U pC~g U pCVg U pCVg U pCvs U pcug U pci/g pcvg U pCug U pcVg pcvg pCvg pcvg pCi/g 8.53E-02 8.06E-01 8.42E-02 4.33E-02 6.53E-02 5.62E-02 1.20E-01 1.30E-01 1.11E-01 3.58E-01 4.56E-02 3.75E-02 6.77E-02 7.57E-02 8.42E-02 4.52E-02 1.03E+00 1.50E-01 1.90E-01 3.20E-01 4.04E-01 3.70E-01 1.57E+01 6.96E-01 2.85E-01!- STL Richland t rptSTLRchSaSum mary2V4.05 A97 RER2 -Replicate Error Ratlo =(S-Dytsqrt(sqrlTUs)+sq(TPUd))l as dernd by ICPT BOA.U Qual -Analyzed for, but the result Is Icss th2n the MdcIfdarrotal Uncert or gamma scan software did not Identify the nuclide.-_STL-RICHLAND 22 QC Results Summary STL Richland STLR Ordered by Method, Batch No, Qc Type,.Date: 30-Dec-03 Report No. : 24555 SOG No.: 24642 Batch Work Order Parameter Result ,- Uncertainty ( 2s) Qual Units Yield Recovery Bias MDCIMDA RICHRCS017 3339264 BLANK OC__ F53TW1 AA 3339264 LCS F53TW1AC RICHRC5017 3339266 BLANK OC F53VM1AA i I E E E E STL RIchland Big rptSTLRchOcSum U r maryV4.05 A97 kC-228%G-1 08M NM-241 31-212 31-214)Q0-60 2S-1 34'S -137 E-:U -5 2-U-1 54 EU-I 55<-40 AN-54 qJB-94:'B-212:'8-214 IA-226 rL-208-5.46E-03
+ 9.58E-02-5.44E-03
+- 1.98E-02 1.25E-02 +-3.69E-02
-3.03E-01
+- 2.70E-01 1.96E-04 +-5.55E-02 7.85E-03 +-2.34E-02 1.82E-02 +-2.87E-02 2.84E-03 +-2.20E-02 4.94E-02 +-7.28E-02 2.32E-02 +- 8.44E-02-3.34E-02
+-4.64E-02 1.25E-01 + 4.47E-01-8.15E-03
+-2.81E-02
-6.25E-04
+- 2.55E-02 1.44E-02 +-3.94E-02
.1.27E-01
+ 5.83E -02 3A44-05 +-5.54E-02
-2.60E-03
+-2.89E-02 U pCVg U pCVg U pC1g U pC/g U pCVg U pCVg U pCVg U pCVg U pCVg U pCVg U pCVg U pCVg U pCVg U pCVg U pCVg U pCVg U pCVg U pCVg 1.83E-01 3.49E-02 5.82E-02 3.71 E-01 1.17E-01 5.26E-02 5.98E-02 4.35E-02 1.40E-01 t .76E-01 7.75E-02 9.20E-01 5.11E-02 4.90E-02 7.36E-02 8.78E-02 1.17E-01 5.28E-02 CS-137 1.21E+00 .s-2.01E-01 pCVg 118% 0.2 4.93E-02%C-228%G-10OSM WM-241 31-212 31-214;0-60;S-134'AS.137:U-1 52.U-154 EU-155 C-40 AN-54 JB-94'8.212 3.14E-02 +. 9.18E-02 2.07E-02 +-2.36E-02
-1.61E202
+-3.71E-02 8.41E-02 +- 4.00E-0I-2.89E-02
+- 6.25E-02-3.76E-03
+-3.18E-02 9.31E-03 +-2.41E-02
-1.56E-02
.-2.60E-02 3.61E-03 +-7.22E-02
-2.69E.02 7- .66E-02 1.39E-03 5.43E-02-2.13E-01
+-3.39E-01
-1.48E-02 4- 2.60E-02-6.56E-03
+-2.42E-02
-7.65E-04
.-3.89E-02 U pCIg U pCVg U pCilg U pCVg U pCVg U pCVg U pCVg U pC/g U pCVg U pCVg U pCVg U pCi/g U pCVg U pCVg U pCIg 1.88E-01 4.68E-02 6.20E-02 7.65E-01 1.22E-01 6.13E 02 5.03E-02 4.39E-02 1.31E-01 1 A2E-01 9.73E-02 6.53E-01 4.51 E-02 4.48E-02 7.06E-02 is .(Resul/Expected)-I as defined by ANSI N13.30.Qual -Analyzed for, but the result Is less than Sbe MdcMdalrrotal Uncert or g32nu scan software did not identify the nudide._STL-RICHLAND 23 QC Results Summary STL Richland STLR Ordered by Method, Batch No, QC Type,.Date: 30-Dec-03 Report No. :24555 SDG No.: 24642 Batch Work Order Parameter Result +-Uncertainty ( 2s) Oual Units Yield Recovery Blas MDCIMDA F53VMlAA PB-214 -6.86E-02
+-5.92E-02 U nCi/a 1.03E-.01 RA-226 TL-208 3339266 LCS F53VM2AC CS-137-2.88E.02
+- 6.25E-02-1.03E-02
+ 2.64E-02 1.25E+00 +- 2.03E-01 U pC-U pCVg 1.22E201 4.65E-02 pCVg 122% 0.2 4.82E-02 No. of Results: 38 STL Richland BiLas (Result/Expecttd)-l as defined by ANSI N1 330.~.rptSTI.RchacSum U Qual -An2ly-zed forbut the result L less than the ltdd/MdarroLalUnceritor gamma scan software did not identify the nucllde.maryV4.05 A97 STL-RICHLAND 2 24
( -I 1 I Lab Name: STL Richland Lot-Sample No.: J3L030207-22 Client Sample ID: 9537-0000 ER-1 rr 't ..ti- .( ' V I' ' (' r r- .(Date: 30-Dec-03 FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00243 Collection Date: 11/12/200310:20:00AM Received Date: 1211/2003 11:00:00 AM Matrix: SOIL Ordered by Client Samnle ID, Batch Na Result Count Total MDCIMDA. Rpt Unit. Yield RstVMDC, Analysis, Total Ss Aliquot PrImar Parameter Qual Error( 2s) Uncert(2 s) Action Lev Lc CRDL(RL) Rst/TotUcert Prep Date Size Slze Detectc Batch: 3339268 RICHRC5017 WorkOrder:
FSXH21M Report DB ID: 9F5XH210 AC-228 5.54E-01 2.10E-01 2.10E-Ot 1.59E-01 pClg (3.5) 12/26/03 05:34 p 336.7 GER8 (5.3) 9 AG-108M 8.72E-03 U 2.06E-02 2.06E-02 3.71 E.02 pClg 0.23 12/26/03 05:34 p 336.7 GER8!2.86E-01 0.85 9 AM-241 1.98E-02 U 6.28E-02 6.28E 02 9.51E-02 pCVg 0.21 12126103 05:34 p 336.7 GER8M 1.03E+00 0.63 9 B1-212 1.54E+00 U 5.61 E-01 5.61E-01 8.95E-01 pCVg (1.7) 12/26/0305:34 p 336.7 GER8!(5.5) g B1-214 8.16E-01 1.70E-01 1.70E-01 7.48E-02 pCVg (10.9) 12126/03 05:34 p 336.7 GER8!(9.6) 9 CO40 -3.56E-03 U 2.55E-02 2.55E.02 4.70E-02 pCVg -0.08 12/26/03 05:34 p 336.7 GER8'1.50E-01 -0.28 9 CS-134 3.48E-02 U 3.SOE-02 3.50E-02 6.64E-02 pCVg 0.52 12/26103 05:34 p 336.7 GER8!1.90E-01 (2.) 9 CS-137 5.58E-02 U 3.19E-02 3.19E-02 6.24E-02 pCVg 0.89 12/26/03 05:34 p 336.7 GER8!3.20E-01 (3.5) 9 EU-152 2.55E-02 U 7.23E-02 7.23E-02 1.29E-01 pCVg 0.2 12/26/03 05:34 p 336.7 GER8M 4.04E-01 0.71 9 EU-154 -2.11 E-02 U 7.86E-02 7.86E-02 1.41 E-01 pCVg -0.15 12/26/0305:34 p 336.7 GERS!3.70E-01 -0.54 9 STL Richland rptSTLRchSarnple V4.05 A97 tn U.'MDCJMDALc
-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.U Qual -Analyzed for, but the result Is less than the MdcIMdalTotat Uncert or gamma scan software did not Identity the nuclide.
H 3S ( -( (. I Lab Name: STL Richland Lot-Sample No.: J3L030207-22 Client Sample ID: 9537-0000 ER-1 Parameter EU-155 K-40 MN-54 NB-94 PS-212 PB-214 RA-226 TL-208 Result Oual 6.32E-02 U 1.23E+01-2-14E-02 U-9.42E-03 U 6.64E-01 7.64E-01 8.1 6E-01 2.33E-01-Count Error ( 2 s)7.33E-02 1.81 E+00 2.72E-02 2.50E-02 1.45E-C1 1.56E-01 1.70E-01 7.09E-02 FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00243 Total MDCIMDA, Rpt Unit, Yield Rst/MDC, Uncert(2 s) Action Lev Lc CRDL(RL) Rst/TotUcert 7.33E-02 1.30E-01 pCi/g 0.49 1.57E+01 (1.7)1.81 E+00 4.40E-01 pCi/g (27.9)(13.5)2.72E-02 4.51 E-02 pCVg -0.47 6.96E-01 -(1.6)2.50E-02 4.35E-02 pCL'g -0.22 2.85E-01 -0.75 1 .45-01 8.64E-02 pCVg (7.7)(9.2)1.56E-01 8.00E-02 pCVg (9.6)(9.8)1.70E-01 7.48E202 pCVg (10.9)(9.6)7.09E.02 4.64E102 pCVg (5.)(6.6)--I' ..~ I 7 1. .r Date: 30-Dec-03 Collection Date: 11/12/2003 10:20:00AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID, Batch No Analysis, Total Sa Aliquot PrImar Prep Date Size Size Detectt 12126/03 05:34 p 336.7 GER8 9 12126103 05:34 p 336.7 GERa 9 12/26/03 05:34 p 336.7 GER8 9 12/26/03 05:34 p 336.7 GER8: 9 12126/03 05:34 p 336.7 GER8: 9 12/26/03 05:34 p 336.7 GER8: 9 12/26/03 05:34 p 336.7 GER81 9 12/2610305:34p 336.7 GER8.9 No. of Results: 18 Comments: STL Richland MDCIIMDA.Lc
-Detection, Decision Level based on Instrument background or blank, adlusted by the sample Efficiency, Yield, and Volume.rptSTLRchSamphe U Qual -Analyzed for, but the result Is less than the Mdc/MdarTotal Uncert or gamma scan softwar did not identify the nuclide.V4.05 A97 U7- : ((Ft U. ( -.' I (V I' 'V El El. (. El .* El i FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00243 Lab Name: STL Richiand Lot-Sample No.: J3L030207-23 Client Sample ID: 9537-0000 ER-2 Date: 30-Dec-03 Collection Date: 11/12/2003 10:25:00 AM Received Date: 12/112003 11:00:00 AM Matrix: SOIL Olriprdred hv Client Sample ID. Batch No Result Count Total MDCIMDA, Rpt Unit, Yield RsttMDC, Analysis, Total Ss Aliquot Prlmar Parameter Qual Error( 2s) Uncer92 s) Action Lev Lc CRDL(RL) Rst/TotUcer1 Prep Date Size Size Detoctc Batch: 3339266 RICHRC5017 WorkOrder:
F5XH31M ReportDB ID: 9FsXH310 AC-228 8.06E-01 2.12E-01 2.12E-01 1.52E-01 pCVg (5.3) 12/26/03 05:35 p 382.1 GER7.(7.6) 9 AG-108M 4.46E-04 U 2.13E-02 2.13-E02 3.77E-02 pC/g 0.01 12126/03 05:35 p 382.1 GER7.2.86E-01 0.04 9 AM-241 -4.97E-03 U 9.32E-02 9.32E-02 1.57E-01 pCVg -0.03 12/26103 05:35 p 3821 GER7.1.03E+00 -0.11 9 81-212 1.31E+00 U 4.60E-01 4.60E-01 8.53E-01 pCVg (1.5) 12126/03 05:35 p 382.1 GER7 (5.7) g B1-214 6.53E.01 1.46E-01 1.46E-01 7.89E-02 pCVg (8.3) 12/26/03 05:35 p 382.1 GER7.(8.9) 9 CO-60 6.30E-03 U 2.56E-02 2.56E-02 4.94E-02 pCilg 0.13 12/26/03 05:35 p 382.1 GER7 1.50E-01 0.49 9 CS-134 2.99E-02 U 2.99E-02 2.99E-02 5.80E-02 pCVg 0.52 12/26/03 05:35 p 382.1 GER7 1.902-01 (2.) 9 CS.137 8.85E-03 U 2.71 E-02 2.71E-02 4.98E-02 pCVg 0.18 12/26/0305:35 p 382.1 GER7 3.20E-01 0.65 9 EU-152 2.56E-02 U 6.77E-02 6.77E-02 1.20E-01 pCGg 0.21 12/26/03 05:35 p 382.1 GER7 4.04E-01 0.76 9 EU-154 -4.46E-02 U 6.92E-02 6.92E-02 1.17E-01 pCVg -0.38 12126/03 05:35 p 382.1 GER7 3.70E-01 -(1.3) 9 STL Richland rptSTLRchSample V4.05 A97 MDCIMDALc
-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.U Qual -Analyzed for, but the result Is less than the Mdc/MdalTotal Vncert or gamma scan software did not Identify the nucilde.
( -J.H:t ( .(. .( [, I ( ' (r f I FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00243 Lab Name: STL Rlchland Lot-Sample No.: J3L030207-23 Client Sample ID: 9537-0000 ER-2 Yield RaIMIOC,-Parameter EU-155 K-40 MN-54 NB-94 PB-212 PB-214 RA-226 TL-208 No. of Results: 18 Result Ou 4.29E-02 U 1.01 E+01-8.56E-03 U-8.51 E-03 U 6.60E-01 8.1 OE-01 6.53E-01 1.94E-01 ual-Count Error ( 2 a)7.33E-02 1.59E+00 2.52E-02 2.39E-02 1.26E-01 1 .54E-01 1.46E-01 6.60E-02 Total Uncert 2 s)7.33E-02 1.59E+00 2.52E.02 2.39E-02 1 .26E-01 1.54E-01 1.46E-01 6.60E-02 MDCIMDA, Rpt Unit, Action Lev Lc 1.30E-01 pCIg 3.84E .01 pCVg 4.31E.02 pClg 4.19E-02 pCVg 6.36E-02 pCVg 8.02E-02 pCVg 7.89E-02 pCVg 4.36E-02 pCVg Yleld Rst/HIC, CROL(RL) RsVTotUcert 0.33 1.57E+01 (1.2)(26.4)(12.8)-0.2 6.96E-01 -0.68-0.2 2.85E-01 -0.71 (10.4)(10.5)(10. 1)(10.5)(8.3)(8.9)(4.4)(5.9)-I I I [ .,. , Date: 30-Dec-03 Collection Date: 11/12/2003 10:25:00AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID, Batch No Analysis, Total Sa Aliquot Primar Prep Date Size Size Detectt 12/26/03 05:35 p 382.1 GER7: 9 12/26/03 05:35 p 3821 GER7: 9 12/26/03 05:35 p 382.1 GER7;9 12t26/0305:35 p 3821 GER7: 9 12/26103 05:35 p 382.1 GER7.9 12t26103 05:35 p 382.1 GER7 9 12/26103 05:35 p 382.1 GER7 9 12126103 05:35 p 382.1 GER7 9 Comments: STL Richland MDCJMDALe
-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efilclency, Yield, and Volume.rptSTLRchSample U Oual -Analyzed for, but the result is less than the Mdc/MdalTotal Uneert or gamma scan software did not identlty the nuctide.V4.05 A97 r .I ( I[-' 1 'If -I FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 200300243 I .' I I I I ~I
- I i:1 r' I .I -.' I Date: 30-Dec-03 Collection Date: 11/1212003 10:25:00 AM Received Date: 12/1/2003 11:00:00AM Matrix: SOIL Lab Name: STL Richland Lot-Sample No.: J3L030207-24 Client Sample ID: 9537-0000 ER-3 Ordered by Client Sample ID, Batch No Result Count Total MDCJMDA, Rpt Unit, Yield RsVMDC, Analysis, Total Sa Aliquot Primar Parameter Oual Error ( 2 s) Uncert 2 *) Action Lev Lc CRDL(RL) RsVTotUcert Prep Date Size Size Detectc Batch: 3339268 RICHRC5017 WorkOrder:
F5XH61M Report DB ID: 9F5XH610 AC-228 9.03E-01 U 2.04E-01 2.04E-01 3.54E-01 pCVg (2.6) 12126/03 05:36 p 361.8 GER6'(8.9) 9 AG-108M -6.83E-03 U 2.22E.02 2.22E.02 3.73E-02 pClg 40.18 12/26/03 05:36 p 361.8 GER6: 2.86E-01 -0.62 9 AM-241 7.57E-02 U 8.05E-02 8.05E-02 1.45E-01 pCI/g 0.52 12/26/0305:36 p 361.8 GER6 1.03E+00 (1-9) 9 BI-212 1.14E+00 U 5.28E-01 528E-01 8.83E-01 pCVg (1-3) 12126103 05:36 p 381.8 GER6 (4.3) 9 81-214 6.47E-01 U 1.35E-01 1.35E-01 2.03E-01 pCVg (3.2) 12/26/03 05:36 p 361.8 GER6S (9.5) 9 CO-60 2.27E-03 U 3.25E-02 3.25E-02 5.96E802 pCi/g 0.04 12/26/03 05:36 p 361.8 GER6.1.50E-01 0.14 9 CS.134 2.10E-02 U 3.25E-02 3.25E-02 6.13E-02 pCVg 0.34 12126/03 05:36 p 361.8 GER6: 1.90E-01 (1.3) 9 GS137 6.99E-02 J 4.05E-02 4.05E.02 4.922-02 pCVg (1.4) 12/26103 05:36 p 361.8 GER6 3.20E-01 (3.5) 9 EU 152 -2.81E-02 U 7.09E-02 7.09E-02 1.21E-01 pCVg -0.23 12/26/0305:36 p 361.8 GER6: 4.04E-01 -0.79 9 EU-154 -9.44E202 U 8.26E-02 8.26E-02 1.28E-01 pCig -0.74 12/26/0305:36 p 361.8 GER6: 3.70E-01 -(2.3) g S1L Richland MDCIMDALc
-Detection, Decision Level based on instrument background or blank, adjusted by the sample Effclcency, Yield, and Volume.rptSILRchSample J Qual -No Uj< qualifier has been assigned and the result Is below the Reporting Limit, RL (CROL) or Reporl Value Is Estimated.
V4.05 A97 U aual -Analyzed for, but the result Is less than the Mdc/MdalTotal Uncert or gamma sean software did not Identify the nuctide.t, 17 C7*' .(" r:.* I (. ( C FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003.00243 C .V .I I ( .' C r Date: 30-Dec-03 Par Lab Name: STL Richland Lot-Sample No.: J3L030207-24 Client Sample 1D: 9537-0000 ER-3 Result ameter Qual Err EU.155 7.40E-02 U 7.(K-40 1.05E+01 I.E MN-54 .6.30E.03 U 2.1 NB.94 -5.71E-03 U 2., PB*212 6.57E-01 1.: PS-214 8.22E-01 1.J RA-226 6.47E-O1 U 1.: lt.208 2.15E-01 5.I Results: 18 Comments::ount Or ( 2 S))5E-02'7E+C0~16E.02 321E-02 34E-01 BI E-01 35E-01 65E-02 Toal!Unce1(2 s)7.05E*02 1.67E400 2.86E-02 2.32E.02 1 .34E-01 1.81lE-01 1 .35E-01 5.65E-02-MOCIMDA, Rpt Unit, Action Lev Le 1.24E-01 pCVg 4.22E-01 pCVg 5.02E-02 pCI/g 4.09E.02 pCVg 6.75E*02 pCI/g 8.57E-02 pCVg 2.03E-01 pCig 4.33E.02 pCVg Yield RsVMDC, CRDL(RL) RstTotUcert 0.6 1.57E1201 (2.1)(25.)(12.6)-0.13 6.96E-01 -0.44-0.14 2.85E-01 -0.49 (9.7Y (9.8)(9.6)(9.1)(3.2)(9.5)(5.)(7.6)-Collection Date: 11/12/2003 10:25:00 AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID. Batch No Analysis, Total Sa Aliquot Primar Prep Date Size Size Detectt 12126/03 05:36 p 361.8 GER6 9 12/26/03 05:36 p 361.8 GER6 9 12/26/03 05:36 p 361.8 GER6 9 12/26/03 05:36 p 361.8 GER6: 9 12/26/03 05:36 p 361.8 GER6 9 12/26/03 05:36 p 361.8 GER6 9 12/26/03 05:36 p 361.8 GER6: 9 12/26/03 05:36 p 361.8 GER6: 9 No. ol STIL Richland MDCIMDA.Lc
-DetectIon, Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yleld, and Volume.rptSTLRchSample J Qual -No Uf< qualllerhas been assigned and the result Is below the Reporting Llml1, RL (CRDL) or Report Value Is EsUmated.V4.05 A97 U Oual -Analyzed for, but the result Is less than the MdclMdajTotal Uncert or gamma scan software did not Identify the nuclide.
( ( '- t U. F I r. ( .I r I I F co, FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00243 Date: 30-Dec-03 Lab Name: STL Richland Lot-Sample No.: J3L030207-25 Client Sample ID: 9537-0000 ER-4 Collection Date: 11/12/2003 10:35:00 AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID, Batch No Result Count Total MDCJMDA, Rpt Unit, Yield Rst/MDC, Analysis, Total Sa Aliquot Primar Parameter Qual Error( 2s) Uncerl2 s) Action Lev Le CRDL(RL) RstotoUcert Prep Date Size Size Detectt Batch: 3339266 RICHRC5017 WorkOrder.
F5XH9IAA ReportDBID:
9F5XH910 AC-228 6.00E-01 1.88E-01 1.88E-01 1.57E-01 pCi/g (3.8) 12/26103 05:37 p 391.3 GER4: (6.4) 9 AG-108M 6.48E-03 U 1.93E-02 1.93E-02 3.48E-02 pCVg 0.19 12/26/03 05:37 p 391.3 GER41 2.86E-01 0.67 9 AM-241 7.77E-02 U 1.42E-01 1.42E-01 2.50E-01 pCVg 0.31 12/26103 05:37 p 391.3 GER4!1.03E+00 (1.1) 9 81-212 7.18E-01 U 4.22E-01 4.22E-01 8.24E-01 pCVg 0.87 12/26/03 05:37 p 391.3 GER4!(3.4) 9 81-214 4.32E-01 U 1.23E-01 1.23E-01 1.832-01 pCVg (2.4) 12/26/03 05:37 p 391.3 GER4'(7.) 9 CO-60 1.93E-02 U 2.81 2-02 2.81 E-02 5.59E-02 pCVg 0.35 12/26/0305:37 p 391.3 GER4!1.502-01 (1.4) 9 CS-134 2.13E-02 U 3.00E-02 3.002-02 5.68E-02 pCVg 0.38 12/26/03 05:37 p 391.3 GER4!1.90E-01 (1.4) 9 CS-137 2.23E-02 U 2.73E-02 2.73E-02 5.11 E-02 pCVg 0.44 12/26/03 05:37 p 391.3 GER4!3.20E-01 (1.6) g EU-152 -1.44E-02 U 6.57E-02 6.57E-02 1.14E-01 pCVg .0.13 12/26/03 05:37 p 391.3 GER4'4.042-01 -0.44 9 EU-154 3.71E-02 U 7.90E-02 7.90E-02 1.53E-01 pClg 0.24 12126/03 05:37 p 391.3 GER4!3.70E-01 a94 9 STL Richland rptSTLRchSample V4.05 A97 w H-MDCIMDA.LC Detection, Decision Level based on Instrument background or blank, adlusted by the sample Efficiency, Yield, and Volume.J Oual -No Ul< qualifier has been assigned and the result Is below the Reporting Limit, RL (CRDL) or Report Value Is Estimated.
U Cual -Analyzed for, but the result Is less than the Mde/MdalTotal Uncert or gamma scan software did not Identify the nucilde.
( -.V , I I ( ' I 1 -FORM I SAMPLE RESULTS SDG:; 24642 Report No.: 24555 COC No.: 2003-00243 Lab Name: STL Richland Lot-Sample No., J3L030207-25 Client Sample ID: 9537-0000 ER-4-Parameter EU-155 K-40 MN.54 NB-94 P8-212 PB5214 RA-226 TL-208 No. of Results: 18-Result Qual 4.98E-02 U 9.57E+OO-1.122E.04 U-7.24E-03 U 6.1 3E-01 5.91 E-01 4.32E-01 1.71 E-01 U-Count Error ( 2 s)7.01 E.02 1 .57E+00 2.832-02 2.01 E.02 1.28E-01 1.60E-01 1.23E-01 6.14E-02 Total UncW1(2 s)7.01 E-02 1.57E+00 2.83E-02 2.01 E-02 1.28E-01 1.60E-01 1.23E-01 6.1 4E-02 MDCfMDA, Rpt Unit, Action Lev La 1.27E-01 pCVg 4.47E-01 pCVg 5.02E-02 pCV/3.47E-02 pClg 6.89E-02 pCVg 8.27E-02 pCVg 8.69E-02 pCVg 8.65E-02 pCVg Yield Rst/MDC, CRDL(RL) RsttrotUcert 0.39 1.57E+01 (1.4)(21.4)(12.2)0.6.96E-01 .0.01-0.21 2.85E-01 -0.72 (8.9)(9.6)(7.2)(7.4)(5.)(7.)(2.)(5.6)-Date: 30-Dec-03 Collection Date: 11/12/2003 10:35:00 AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID, Batch No Analysis, Total Sa Aliquot Primer Prep Date Size Size Detectc 12/26/03 05:37 p 391.3 GER4!9 12/26/03 05:37 p 391.3 GER41 9 12/26/03 05:37 p 391.3 GER41 9 12126/03 05:37 p 391.3 GER4!9 12/26/03 05:37 p 391.3 GER4: 9 12126103 05:37 p 391.3 GER41.9 12/26/03 05:37 p 391.3 GER4'9 12/26/03 05:37 p 391.3 GER4!9 Comments: STL lRchland MDCJMDALc-Detection.
DecisIon Level based onInstrumentbackground orblank, adjustodbythe sample Efficiency, Yield, and Volume.rptSTLRhSample J Qual -No UlI qualifler has been assigned and the result Is below the Reporting Lmit, RL (CRDL) or Report Value Is Estimated.
V4.05 A97 U Qual -Analyzed for, but the result Is less than the Mdc/MdarTotal Uncert or gamma scan software did not Identify the nuClide.w I- I u rI I I I I I FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00243 Date: 30-Dec-03 Collection Date: 11/12/2003 10:35:00 AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Lab Name: STL Richland Lot-Sample No.: J3L030207-26 Client Sample ID: 9537-0000 ER-5 Ordered by Client Sample ID. Batch No.Result Count Total MDCIMDA. Rpt Unit, Yield RstUMDC, Analysis, Total Sa Aliquot PrImar.Parameter Qual Error (2s) Unceru(2 s) Action Lev Lc CRDL(RL) R&trotUcert Prep Date Size Size Detectc Batch: 3339266 RICHRCS017 WorkOrder:
FXJC1AA Report DB ID: 9F5XdC10 AC-228 9.83E-01 2.19E-01 2.19E-01 1.83E-01 pCVg (5.4) 12126/03 05:39 p 340.2 GER5'(9.) g AG-1o0M 6.86E-.03 U 2.352-02 2.35E-02 4.23E-02 pCVg 0.16 1212610305:39 p 340.2 GER5'2.86E-01 0.58 9 AM-241 -1.41E203 U 5.79E-02 5.79E.02 9.74E-02 pC'Ug -0.01 12/26/03 05:39 p 340.2 GER55 1.03E+00 .0.05 9 BI-212 1.40E+00 U 5.84i-01 5.84E-01 9.68E-01 pCVg (1.4) 12/26/03 05:39 p 3402 GER5S (4.8) 9 Bl-214 7.57E-01 1.74E-01 1.74E-01 9.06E-02 pCLg (8.4) 12/26/03 05:39 p 340.2 GER5S (8.7) 9 CO 60 -1.59E-02 U 2.87E-02 2.87E-02 4.94E-02 pCVg -0.32 12/26/03 05:39 p 3402 GER5S 1.50E-01 -(1. 1) 9 CS-134 5.24E-02 U 3.63E-02 3.63E-02 7.15E-02 pCVg 0.73 12/26/03 05:39 p 340.2 GER53 1.90E-01 (2.9) g CS-137 9.96E-02 U 4.03E-02 4.03E-02 7.92E-02 pClg (1.3) 12/26/03 05:39 p 340.2 GER53 3.20E-01 (4.9) 9 EU-152 -6.10E-02 U 8.40E-02 8.40E.02 1.29E-01 pCVg -0.47 12/26/03 05:39 p 340.2 GER5g 4.04E-01 -(1.5) g EU-154 1.93E-02 U 9.52E-02 9.52E-02 1.75E-01 pCVg 0.11 12/26/03 05:39 p 340.2 GER51 3.702-01 0.41 9 STL Richland rptSTLRchSample V4.05 A97 w MDCJMDA.Lc
-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.J Qual -No UlI qualifier has been assigned and the result Is below tle Reporting Limit, RL (CRDL) or Report Value Is Estimated.
U Qual -Analyzed for, but the result Is leas than the Mdo/MdalTotal Uncert or gamma scan software did not Identify the nucilde.
F ( f I I I I f FORM I SAMPLE RESULTS Lab Name: STL Richland SDG: 24642 Lot-Sample No.: J3L030207-26 Report No.: 24555 fieant aimpla iDn a9537-n000lfl FR-S COC No.: 2003-00243 I ' I I(II I Date: 30-Dec-03 Parn No. a Result C ameter Qual Err EU*155 8.54E-02 U 7.7 K 40 1.01E+01 1.6 MN-54 4.68E-03 U 3..NB-94 -9.29E-03 U 2,e PB-212 826E-01 1E PB-214 721E-01 1.1 RA*226 7.58E-01 1.TL-208 2.52E-01 6.Count orf( 2s)2E-02 7E+00 32E-02 54E-02 59E-01 B.E-01 74E-01 34E-02 Total Uncerg 2 s)7.72E-02 1.67E+00 3.32E-02 2.54E-02 1.59E-01 1.81E-01 1.74E-01 6.34E*02 MDC[MDA, Rpt Unit, Action Ley LC 1.35E-01 pCVg 4.87E-01 pCVg s.96E-02 pCIg 4.36E-02 pCVg 7.11E-02 pCVg 1.00E-01 pCIIg 9.06E-02 pCitg 4.72E-02 pCVg Yield RstlMDC, CROL(RL) Rst/TOtUcert 0.63 1.57E+01 (2.2)(20.7)(12.1)0.08 6.96E-01 0.28-0.21 2.85E-01 -0.73 (11.6)(10.4)(7.2)(8.)(8.4)(8.7)(5.3)(8.)Collection Date: 11/12/2003 10:35:00 AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID, Batch No Analysis, Total Sa Aliquot Primar Prep Date Size Size Detectc 12/26/03 05:39 p 340.2 GERS 9 12/26103 05:39 p 340.2 GERS 9 1212610305:39 p 340.2 GERS 9 12/2610305:39 p 340.2 GERS: 9 12126103 05:39 p 340.2 GERS: 9 1226/03 05:39 p 340.2 GER5: 9 1226/03 05:39 p 340.2 GER5!9 12/26/03 05:39 p 340.2 GER5: 9[Results:
18 Comments, STL Rlchland MDCIMDA.Lc
-Detection, Decision Level based on instrument background or blank, adjusted bythe sample Efficiency, Yield, and Volume.rptSMtRchSample J Oual -No Uj< qualifier has been assigned and the result Is bWlow the Reporting Umit, RL (CRDL) or Report Value is Estimated.
V4.05 A97 U Cual -Analyzed for, but the result Is less than the Mdc/MdalTotal Uncert or gamma scan software did not Identify the nuclide.w r ( I .r, I .r ( .30 .( '. ( -- (03 FORM I Date: 30-Dec-03 Lsb Name: STL Richland Lot-Sample No.: J3L030207-27 Client Sample ID: 9537-0000 ER-6 SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003.00243 Collection Date: 11/12/2003 10:38:00 AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID, Batch No Result Count Total MDCIMOA, Rpt Unit, Yield RAt/MDC, Analysis, Total Sa Aliquot Primar Parameter Oual Error( 23) Uncet(2 s) Action Lev Lc CRDL(RL) RsttTotUcert Prep Date Size Size Detect(Batch: 3339266 RICHRC5O17 WorkOrder:
FSXJDIM Report DB ID: 9F5XJD10 AC-228 6.42E-01 2.01E-01 2.01E-01 1.55E-01 pCVg (4.2) 12/26/03 08:17 p 385.1 GER4U (6.4) 9 AG-108lM -323E-03 U 2.07E-02 2.07E-02 3.56E-02 pCi/g -0.09 12126/03 08:17 p 385.1 GER4!2.86E-01 -0.31 9 AM-241 -4.97E-02 U 1.58E-01 1.5s8E-01 2.65E-01 pCI/g -0. 19 12/2603 08:17 p 385.1 GER41 1.03E+00 -0.63 9 Bl1212 5.14E-01 U 4.10E-01 4.10E-01 7.91E-01 pCVg 0.65 12/26/03 08:17 p 385.1 GER4!(2.5) 9 Bl-214 6.33E-01 1.27E-01 1.27E-01 8.57E-02 pCi/g (7.4) 12/26/03 08:17 p 385.1 GER4'(10.) g CO-60 1.52E-03 U 2.77E-02 2.77E-02 5.13E-02 pCl/g 0.03 12/26/03 08:17 p 385.1 GER4'1.SOE-01 0.11 9 CS.134 5.68E-02 U 3.18E-02 3.18E-02 6.40E-02 pCVg 0.89 12/26/03 08:17 p 385.1 GER4'1 .90E-01 (3.6) 9 CS0137 2.44E-02 U 2.85E-02 2.85E-02 5.33E-02 pCIg 0.46 12/26/03 08:17 p 385.1 GER4!3.20E-01 (1.7) g EU.152 *2.73E-02 U 6.66E-02 6.66E-02 1.14E-01 pCVg -0.24 12/26/03 08:17 p 385.1 GER4'4.04E-01 -0.82 9 EU.154 1.65E-02 U 7.23E-02 7.23E*02 1.38E.01 pCVg 0.12 12/26/03 08:17 p 385.1 GER4'3.70E-01 0.46 9 SIL mlcniana rptSTI.RchSample V4.OS A97 W 0J MLICIMDA,Lc
-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efflciency, Yield, and Volume.J Oual -No Uic qualifier has been assigned and the result Is below the Reporting Limit, RL (CROL) or Report Value Is Estimated.
U Qual -Analyzed for, but the result Is less than the MdcJMdalTotal Uncert or gamma scan software did not Identify the nuclide.
( .(*, .[*' I C. ( C.C Vi FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003.00243 Lab Name: STL Richland Lot-Sample No.: J3L030207-27 Client Sample ID: 9537-0000 ER-6 Parameter El)- 55 K40 MN.54 NB-94 PB-212 P8-214 RA-228 TL-208 No. of Results: 18 Result Oual 1.38E-01 U 926Ea00 1.OOE-02 U-8.78E-03 U s.93E-01 7.95E-01 6.33E-01 2.22E-01-Count Error ( 2 s)8.13E-02 1.48E+00 3.01 E-02 2.34E-02 1.28E-01 1.59E-01 1.27E-01 5.81 E-02 Total Uncerg 2 s)8.13E-02 1.48E+00 3.01 E-02 2.34E-02 1.28E-01 1.59-E01 1.27E-01 5.81 E.02-MDCIMDA, Rpt Unit, Action Lev Lc 1.49E-01 pCVg 3.49E-01 pCVg 5.49E-02 pCtg 3.99E-02 pCVg 7.27E-02 pC0g 8.58E-02 pCVg 8.57E-02 pCIIg 4.36E-02 pCVg Yield RstlMDC, CRDL(RL) Rst/TotUcert 0.93 1.57E+01 (3.4)(26.6)(12.5)0.18 6.96E-01 0.67-0.22 2.85E-01 -0.75 (8.2)(9.3)(9.3)(10.)(7.4)(10.)(5.1)(7.6)-Date: 30-Dec-03 Collection Date: 11/12/2003 10:38:00 AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID, Batch No Analysis, Total Sa Aliquot Primar Prep Date Size Size Detectc 12126103 08:17 p 385.1 GER41 9 12/26/03 08:17 p 385.1 GER41 9 12/26/03 08:17 p 385.1 GER4A 9 t1226103 08:17 p 385.1 Gr=R4!12126103 08:17 p 385.1 GER41 9 12/26/03 08:17 p 385.1 GER4!9 12/26/03 08:17 p 385.1 GER4!9 12/26/03 08:17 p 385.1 GER4: 9 Comments: STL RichLand MDCJMDA.Lc
- Detoctilon, Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.rptSTLRchSample J Oual -No Uk< qualifier has been assigned and the result Is below the Reporting Limit, RL (CRDL) or Report Value Is Estimated.
v4.05 A97 U Oua1 -Analyzed for, but the result Is ices than the Mde/MdalTotal Unceert or gamma scan software did not Identify the nuclide.w ON r(-~ [ (I ( -' ( ---- f I FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00242 I ( ( ( .( ( .Date: 30-Dec-03 Collection Date: 11/14/2003 10:54:00 AM Received Date: 12/1/2003 1 1:00:00 AM Matrix: SOIL Lab Name: STL Richland Lot-Sample No.: J3L030207-13 Client Sample ID: 9537-0000D009F Ordered by Client Sample ID. Batch No Result Count Total MDCIMDA, Rpt Unit, Yield RstiWDC, Analysis, Total Sa Aliquot Primar Parameter Qual Error ( 2 s) Uncert 2 a) Action Lev Le CRDL(RL) RstftrotUcert Prep Date Size Size Detectc Batch: 3339264 RICHIRC5017 WorkOrder.
FSXG31AA Report DS ID: 9FSXG310 AC-228 5.93E-01 1.60E-01 1.60E-01 1.52E-01 pCVg (3.9) 12/26/03 06:52 a 417.7 GER6: (7.4) 9 AG-108M 1.41E-04 U 1.73E402 1.73E-02 3.02E-02 pCIg 0. 12/26/03 06:52 a 417.7 GER6'2.86E-01 0.02 9 AM-241 1.61E-02 U 7.19E-02 7.19E-02 1.20E-01 pCI~g 0.13 12/26/03 06:52 a 417.7 GER6'1.03E+00 0.45 9 Bl-212 8.33E-01 U 3.75E-01 3.752-01 7.27E-01 pCVg 0.87 12126/03 06:52 a 417.7 GER6'(3.4) 9 B1-214 5.80E-01 U 1.18E-01 1.18E-01 1.79E-01 pCVg (3.2) 12/26/0306:52 a 417.7 GER6E (9.8) 9 CO-60 -1.38E-02 U 2.71 202 2.71E-02 4.62E-02 pClg .0.3 12/26/0306:52 a 417.7 GER6!1.502-01 -(1.) 9 CS-134 1.77E-02 U 2.592-02 2.59E-02 4.95E-02 pCIg 0.36 12/26/03 06:52 a 417.7 GER6S 1.90E-01 (1.4) 9 CS-137 2.02E-02 U 2.55E-02 2.55E-02 4.78E-02 pCVg 0.42 12/26/0306:52 a 417.7 GER65 3.20E-01 (1.6) 9 EU-152 4.08E-02 U 6.122-02 6.12£-02 1.08E-01 pCi/g 0.38 12/26/03 06:52 a 417.7 GER69 4.04E-01 (1.3) 9 EU-154 2.71E-03 U 7.70E-02 7.70E-02 1.41E-01 pCVg 0.02 12/26/03 06:52 a 417.7 GER61 3.70E-01 0.07 9 STL Rlchland rptSTLRchSample V4.05 A97 MI W MDCIMDA..Lc-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.J Qual -No Uj< qualifier has been assigned and the result Is below the Reporting Limit, RL (CRDL) or Report Value Is Estimated.
U Qual -Analyzed for, but the result Is less than the MdIc/MdaiTotal Uncert or gamma scan software did not Identity the nucilde.
-( ..I I ( ( (.Lab Name: STL Richlan Lot-Sample No.: J3L030207-1 Client Sample ID: 9537-0000-0 Result Parameter Oual EU-155 4.71 E-02 U K-40 1.03E+01 MN-54 1.13E-02 U NB-94 -2.74E-03 U PB-212 5.05E-01 Ps-214 6.56E-01 RA-226 5.80E-01 U TL-208 1.92E-01 No. of Results: 18 Comments: FORM I SAMPLE RESULTS d SDG: 24642 13 Report No.: 24555 09F COC No.: 2003-00242 Count Total MDCIMDA, Rpt Unit, Yield Error( 2s) Uncert(2 s) Action Lev Lc CRDL(RL)5.95E-02 5.95E-02 1.04E-01 pCVg 1.57E+01 1.60E.00 1.60E+00 3.07E-01 pCI/g 2.38E-02 2.38E-02 4.47E-02 pC/g 6.96E-01 2.07E.02 2.07E-02 3.68E-02 pCVg 2.85E-01 1.16E-01 1.16E-01 6.97E-02 pCVg 1.44E-01 1.44E-01 6.85E-02 pCig 1.18E-01 1.18E-01 1.79E-01 pCVg 5.78E-02 5.78E-02 3.66E-02 pCVg Date: 30-Dec-03 Rst/MDC, RstrotUcert 0.45 (1.6)(33.8)(12.9)0.25 0.95-0.07-0.26 (72)(8.7)(9.6)(9.1)(3.2)(9.8)(5.2)(6.6)-Collection Date: 11/14/200310:54:00AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID. Batch No Analysis, Total So Aliquot Primar Prep Date Size Size Dctoctc 12/26/03 06:52 a 417.7 GER6'9 12126/03 06:52 a 417.7 GER6'g 12/26/03 06:52 a 417.7 GER6!9 12/26/03 06:52 a 417.7 GER6'g 12/26/03 06:52 a 417.7 GER6'9 12/26/03 06:52 a 417.7 GER61 9 12/26/03 06:52 a 417.7 GER65 9 12/26/03 06:52 a 417.7 GER61 9 STL Rlchland MDCfMDALc
-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efficlency.
Yield, and Volume.rptSTLRchSample J Qual -No Ulc qualifier has been assigned and the result Is below the Reporting Limit. RL (CRDL) or Report Value Is Estimated.
VA05 A97 U Qual -Analyzed for, but the result Is less than the Mdc/MdalTotal Uncert or gamma scan software did not Identity the nuclide.on I I ' f -I ( ' I f ' f .I I -.(. .( ' -FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003.00242 Date: 30-Dec-03 Collection Date: 11/14/200310:55:00AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Lab Name: STL Richland Lot-Sample No.: J3L030207-14 Client Sample ID: 9537-0000-010F Ordered by Client Sample ID, Batch No Result Count Total MDC1MDA, Rpt Unit, Yield RstlMDC, Analysis, Total Sa Aliquot Primar Parameter Oual Error( 2 s) Uncerl(2 s) Action Lev Lc CRDL(RL) RstrrotUcert Prep Date Size Size Detectc Batch: 3339264 RICHRC5017 WorkOrder F5XHC1AA Report D0 ID: 9FSXHC10 AC-228 5.54E-01 U 1.96E-01 1.96E-01 2.91E-01 pCig (1-9) 12/26/03 06:52 a 403.3 GER7!(5.6) 9 AG-108M -3.64E-03 U 1.75E-02 1.75E-02 3.06E-02 pCi/g -0.12 12/26/03 06:52 a 403.3 GER7'2.86E-01 -0.42 9 AM-241 -1.24E-02 U 8.57E-02 8.57E*02 1.44E-01 pC/g -0.09 12126/03 06:52 a 403.3 GER7!1.03E+00 -0.29 9 BI-212 3.52E-01 U 3.52E-01 3.52E-01 6.77E-01 pCVg 0.52 12/26/03 06:52 a 403.3 GER7'(2.) 9 Bl-214 5.32E-01 U 1.28E-01 1 28E-01 1.88E-01 pCVg (2.8) 12/26103 06:52 a 403.3 GER7V (8.3) 9 CO-60 8.77E.03 U 2.20E-02 2.20E-02 4.40E-02 pCilg 0.2 12/26/03 06:52 a 403.3 GER7'1.50E-01 O.S g Cs-134 2.1 OE-02 U 2.95E-02 2.95E.02 5.55E-02 pCVg 0.38 12/26/03 06:52 a 403.3 GER7'1.90E-01 (1.4) 9 Cs-137 -2.90E-03 U 2.60E-02 2.60E-02 4.60E-02 pCI/g -0.06 12/26/03 06:52 a 403.3 GER7'3.20E-01 -0.22 9 EU-152 4.53E-02 U 6.51 E-02 6.51E-02 1.14E-01 pCVg 0.4 12/26/03 06:52 a 403.3 GER7'4.04E-01 (1.4) 9 EU.154 1.80E-02 U 7.31 E-02 7.31E.02 1.39E-01 pC/g 0.13 12/26/0306:52 a 403.3 GER7'3.70E-01 0.49 9 STL Rlchland MDCIMDALc
-Detection, Decision Level basd on instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.rptSTLRchSampie J Quai -No Ul qualifier has been assigned and the result Is below the Reporting Limit, RL (CRDL) or Report Value Is Estimated.
V4.05 A97 U Qual -Analyzed for, but the result Is less than the Mdc/MdalTotal Uncert or gamma scan software did not identfy the nuclde.a%VI c-0I,- ' ' 'I -' ( 'm.I Pan No. of Lab Name: STL Richland Lot-Sample No.: J3L030207-14 Client Sample ID: 9537-0000-01OF Result C ameter Qual Em EU 155 3.65E-02 U 6.7 K-40 9.21 E+00 1.4 MN-54 1.81 E-02 U 2.5 NB-94 *4.37E-03 U 2.2 PB-212 4.86E-01 1.l PB-214 5.21E-01 1.RA-226 5.33E-01 1.2 TL-208 1.63E-01 4.Results: 18 Comments:~ount Total Dr (2 z) Uncen(2 s)'2E-02 6.72E-02 8E+00 1 .48E+00 4E.02 2.54E.02!8E-02 2.28E.02)3E-01 1.03E-01 14E-01 1 .34E-01?8E-01 1.28E-01?6E-02 4.76E-02 FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00242 MDCIMDA, Rpt Unit, Yield Rst/MDC, Action Lev Lc CRDL(RL) RsvrotUcert 1.19E-01 pCitg 0.31 1.57E+01 (I. 1)4.40E.01 pCVg (20.9)(12.4)4.83E-02 pCltg 0.37 6.96E-01 (1.4)4.06E-02 pCVg -0.11 2.85E-01 .0.38 8.35E-02 pCig (5.8)(9.4)6.73E.02 pCVg (7.7)(7.8)7.11E.02 pCig (7.5)(8.3)3.71 E-02 pCVg (4.4)(6.9)Date: 30-Dec-03 Collection Date: 11/14/200310:55:00AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID. Batch No Analysis, Total Sa Aliquot Primar Prep Date Size Slze Detectc 12/26/03 06:52 a 403.3 GER7V 12/26/03 06:52 a 403.3 GER7'g 12/26/03 06:52 a 403.3 GER7'9 12126t03 06:52 a 403.3 GER7'9 12/26/03 06:52 a 403.3 GER7S 9 12/26/03 06:52 a 403.3 GER7S 9 12/26/03 06:52 a 403.3 GER7S 9 12/26/03 06:52 a 403.3 GER7S 9 12/26/03 06:52 a 403.3 GER7S 9 12260 065 a ......... 4_.3 _GR.STL Rlchland MDCIMDA.Lc
-Detection, Decision Level based on Instrument background or blank, adlusted by the sample EfficIency, Yield, and Volume.rptSTLRchSample J Qual -No Ul< quallfier has been assigned and the result Is below the Reporting Umit, RL (CRDL) or Report Value Is Estimated.
V4.05 A97 U Qual -Analyzod for, but the result Is less than the MdclMdalTotal Uncert or gamma scan software did not IdentIfy the nuclide.01 al I -( --_F R M I I D a t e ( 30l -D 3 FORM I Date: 30-Dec-03 Lab Name: STL Richland Lot-Sample No.: J3L030207-15 Client Sample ID: 9537-0000-011F01 SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00242 Collection Date: 11/13/2003 2:25:00 PM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID, Batch Nc Result Count Total MDCIMDA, Rpt Unit, Yield Rst/MDC, Analysis, Total Sa Aliquot PrImai Parameter auat Error ( 2 s) Uncert 2 s) Action Lev Lc CRDL(RL) RstrotUcert Prep Date Size Size Detect#Batch: 3339266 RICHRC5O17 Work0rder F5XHDlM Report DB ID: 9F5XHD10 AC-228 5.79E-01 1.56E-01 1.56E-01 1.38E-01 pCVg (4.2) 12/26/03 01:55 p 383.8 GER7 (7.4) 9 AG.108M 7.43E-03 U 1.952-02 1.95E-02 3.57E-02 pCVg 0.21 12126/03 01:55 p 383.8 GER7 2.86E-01 0.76 9 AM-241 -6.98E-02 U 8.89E-02 8.89E-02 1.442-01 pCVg -0.49 12/26/03 01:55 p 383.8 GER7 1.03E+00 -(1.6) 9 B1-212 4.34E-01 U 3.55E-01 3.55E-01 6.97E-01 pCVg 0.62 12/26103 01:55 p 383.8 GER7.(2.4) 9 B5-214 4.88E-01 U 1.21E-01 1.21E-01 1.79E-01 pCVg (2.7) 12/26/03 01:55 p 383.8 GER7: (8.) 9 CO-60 -1.04E-02 U 1.92E-02 1.92E-02 3.32E-02 pClg -0.31 12/26/03 01:55 p 383.8 GER7: 1.50E-01 .(1.1) 9 CS-134 2.54E-02 U 2.69E-02 2.69E-02 5.27E-02 pCVg 0.48 12/26/03 01:55 p 383.8 GER7 1.90E-01 (1-9) 9 CS-137 3.38E-02 U 2.92E-02 2.92E-02 5.62E-02 pCVg 0.6 12/26/03 01:55 p 383.8 GER71 3.20E-01 (2.3) 9 EU-152 -2.19S-02 U 6.89E-02 6.89E-02 1.16E-01 pCVg -0.19 12/26/03 01:55 p 383.8 GER7: 4.04E-01 -0.63 9 EU-154 4.79E-02 U 7.30E-02 7.30E-02 1.472-01 pCVg 0.33 12/26/0301:55 p 383.8 GER7'3.70E-01 (1-3) 9 STL Richland rptSTLRchSample V4.05 A97-4 UDCIMDA,Lc
-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.J Oual -No Ul qualifier has been assigned and the result Is below the Reporting Limit, RL (CRDL) or Report Value is Estimated.
U Qual -Analyzed tor, but the result Is less than the Mdc/MdalTotal Uncert or gamma scan software did not Identify tho nuclide.
(7. -.I co H V.-f f' I.* rj. (*.... V I'FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00242
-Par No.o Lab Name: STL Richiand Lot-Sample No.: J3L030207-15 Client Sample ID: 9537-0000-011 F01 Result Count Total ameter Cual Error ( 2 s) Uncert(2 s)0U-155 .2.82E-02 U 6.88E-02 6.88E-02 K-40 1.05E+01 1.67E+00 1.67E+00 MN-54 1.41 E.02 U 2.69E-02 2.69E-02 NB-94 1.43E-02 U 2.33E-02 2.33E-02 PB-212 6.01E-01 1.03E-01 1.03E-01 PB-214 5.54E-01 1.36E-01 1.36E-01 RA-226 4.88E-01 1.21E-01 1.21E-01 TL-208 2.04E-01 U 5.48E-02 5.48E-02 MDCIMDA, Rpt Unit, Action Lev Lc 1.22E.01 pCVg 4.50E-01 pCVg 5.03E-02 pCVg 4.52E-02 pCi/g 5.86E-02 pCI/g 7.77E-02 pCVg 7.78E-02 pClg 8.40E-02 pCl/g Yield Rst/MDC, CRDL(RL) Rst/lotUcert 0.23 1.57E+01 0.82 (23.3)(12.6)0.28 6.96E-01 (1.)0.32 2.85E-01 (1.2)(8.5)(9.7)(7.1)(8.1)(6.3)(8.)(2.4)(7.4)-1. 'r'.. ('t'"I'Date: 30-Dec-03 CollectIon Date: 11/13/2003 2:25:00 PM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID. Batch No Analysis, Total Sa Aliquot Primar Prep Date Size Size Detectc 12/26/03 01:55 p 383.8 GER7'9 12/26/03 01:55 p 383.8 GER7: 9 12/26/03 01:55 p 383.8 GER7: 9 12/26103 01:55 p 383.8 GER7: 9 12/26/03 01:55 p 383.8 GER7: 9 12/26/03 01:55 p 383.8 GER7: 9 12/26/0 3 01:55 p 383.8 GER7'9 12/26/03 01:55 p 383.8 GER7'9 ,f Results: 18 Comments: STL Richland MDCIMDA.Lc
-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efftclency, Yield, and Volume.rptSTLRchSample J Oual -No Ujc qualifier has been assigned and the result Is below the Reporting Limit, RL (CRDL) or Report Value Is Estimated.
V4.05 A97 U Oual -Analyzed for, but the result Is less than the MdcHtdalTotal Uncert or gamma scan software did not Identity the nucllde.rD F r (II ( r ( .((I r i .. ( I.(,-Lab Name: STL Richland Lot-Sample No.: J3L030207-16 Client Sample ID: 9537-0000-011 F02 FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: .2003-00242 MDCIjDA, Rpt Unit, Yield Rst/lDC, Action Lev Lc CRDL(RL) RsVrotUcert FSXHEtM Report OS ID: 9F5XHE10 Collection Date: 11/13/2003 2:30:00 PM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID, Batch No Analysis, Total Sa Aliquot Primar Prep Date Size Size Detectc Date: 30-Dec-03 TobI.Parameter Batch: 3339266 AC.228 AG-i 08M AM-241 B1-212 BI-214 CO-60 CS-134 CS-137 EU-152 EU-1 54 Result au RICHRC5017 5.91E-01 1.22E-02 U-2.65E-02 U 7.93E-01 U 4.81 E-01 U 3.03E-03 U 5.1 6E-02 U 1.98E-02 U*7.11 E-02 U-3.01 E-02 U Count al Error ( 2 s)Total Uncert( 2 s)Work Order:-2.06E-01 2.1 8E-02 1 .44E-0l 4.62E-01 1 .34E201 2.67E-02 3.35E-02 2.95E-02 7.21 E-02 1 .OSE-01 2.06E-01 1.61E-01 pCVg (3.7) 12/26/03 01:56 p (5.7)344.8 GER4!9 2.1 8E202 1.44E-01 4.62E-01 1.34E-01 2.67E-02 3.35E-02 2.95E-02 7.21 E.02 1 .05E-01 4.00E-02 pCiVg 2.44E-01 pCVg 9.09E-01 pCVg 2.02E-01 pCVg 5.08E.02 pCVg 6.74E-02 pCVg 5.49E-02 pC/g 1.17E-01 pCig 1.84E-01 pCVg 2.86E-01 1.03E+00 1.50E-01 1.90E-01 3.20E-01 4.04E-01 3.70E-01 0.3 (1.1)-0.11-0.37 0.87 (3,4)(24)(7.2)0.06 0.23 0.77 (3.1)0.36 (1.3)-0.61-(2.)-a.16-0.57 12/26/03 01:56 p 12126/03 01:56 p 12/26/03 01:56 p 12126/03 01:56 p t126/03 01:56 p 12/26/03 01:56 p 12/26/03 01:56 p 12/26/03 01:56 p 12/26/0301:56 p 344.8 9 344.8 9 344.8 9 344.8 9 344.8 9 344.8 g 344.8 9 344.8 9 344.8 9 GER4'GER4!GER42!GER4!GER4,'GER4!GER4.1 GER4!GER4!SiT Richland rptSTL.RchSample V4.05 A.97 0Ch%D MDCIMDA,Lc
- Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efficlency, Yield, and Volume.J Qual -No UI< qualifier has been assigned and the result Is below the Reporting Umit, RL (CRDL) or Report Value Is Estimated.
U Oual -Analyzed for, but the result Is less than the Mde/MdalTotail Uneert or gamma scan software did not Identify the nuclide._ _ _ _ _
I 'I I ( I~ -*.f I I I I f I...FORM I SAMPLE RESI SDG: 2464 Report No.: 2455 COC No.: 200: JLTS Date: 30-Dec-03_ .Par, No. ol Lab Name: STL Richland Lot-Sample No.: J3L030207-16 Client Sample ID: 9537-0000-011 F02 Result Count arneter Oual Error ( 2 s)EU-155 3.46E-02 U 8.04E-02 K-40 1 .02E+01 1.67E+00 MN-54 -6.50E203 U 2.74E-02 NB-94 1.50E-02 U 2.51 E-02 PB-212 5.31 E-01 1.18E-01 P8-214 5.73E-01 1.31E-01 RA-226 4.81E-01 U 1.34E-01 TL*208 1.61E-01 5.65E-02 Total MDCiMDA, Rpt Unit, Uncert 2 s) Action Lev Lc 8.04E-02 1 A3E-01 pCV/1 .67E+00 4.76E-01 pCig 2-74E-02 4.78E-02 pCig 2.51 E-02 4.80E-02 pCVg 1.1 8E-01 8.60E-02 pCVg 1.31 E0I 8.05E-02 pCi/g 1.34E-01 2.02E-01 pCVg 5.65E-02 4.65E-02 pClg 2 Collectlon Date: 11/13/2003 2:30:00 PM;5 Received Date: 12/1/2003 11:00:00 AM 1-00242 Matrix: SOIL Ordered by Client Sample ID, Batch No Yield RstlMDC, Analysis, Total Sa Aliquot Primar CRDL(RL) Rst/rotUcert Prep Date Size Size Detectc 0.24 12/26103 01:56 p 344.8 GER41 1.57E+01 0.86 9 (21.4) 12/26/03 01:56 p 344.8 GER4: (12.2) g-0.14 12/26/03 01:56 p 344.8 GER41 6.96E-01 -0.47 9 0,31 12/26/03 01:56 p 344.8 GER4: 2.85E-01 (1.2) 9 (6.2) 12/26/03 01:56 p 344.8 GER4!(9.) 0 (7.1) 12/26/03 01:56 p 344.8 GER4'(8.8) g (2.4) 12/26/03 01:56 p 344.8 GER4'(72) 9 (3.5) 12/26103 01:56 p 344.8 GER4'(5.7) 9 t Results: 18 Comments: STL Richland MDCIMDALc
-Detection, DecisIon Level based on Instrument background or blank, adlusted by the sample Efficiency, Yield, and Volume.rptSTLRchSample J Cual -No UI< qualifler has been assigned and the result Is below the Reporting Limit, RL (CRDL) or Report Value Is Estimated.
V4.05 A97 U Cual -Analyzed for, but the result Is less than th Mde/dalTotal Uncert or gamma scan software dId not IdentIfy the nuclide.0 I ( 'I I I I I (( II r F r- -FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00242 Date: 30-Dec-03 Collection Date: 11/14/2003 10:57:00 AM Received Date: 1211/2003 11:00:00 AM Matrix: SOIL Lab Name: STL Rlchland Lot-Sample No.: J3L030207-17 Client Sample ID: 9537-0000-012F Ordered by Client Sample ID. Batch No.Result Count Total MDCIMDA, Rpt Unit, Yield Rat/MDC, Analysis, Total Ss Aliquot Primar Parameter Qual Error ( 2 s) Uncer! 2 s) Action Lev Lc CRDL(RL) RslVTotUcert Prep Date Size Size Detectc Batch: 3339266 RICHRCS017 Work Order: F5XHG1M Report DB ID: 9FSXHG10 AC.228 7.37E-01 2.24E-01 2.24E-01 1.62E-01 pCVg (4.5) 12126103 01:58 p 335.7 GER5!(6.6) 9 AG-108M .1.57E.02 U 2.36E-02 2.36E-02 3.93E-02 pCVg -0.4 12/26/03 01:58 p 335.7 GER5.2.86E-01 -(1.3) 9 AM-241 2.54E-03 U 5.95E-02 5.95E.02 8.88E-02 pCVg 0.03 12(26/03 01:58 p 335.7 GER5!1.03E+00 0.09 9 Bl-212 7.65E-01 U 4.68E-01 4.68E-01 9.17E-01 pCVg 0.83 12/2610301:58 p 335.7 GER5!(3.3) 9 81-214 6.48E-01 1.73E-01 1.73E-01 9.01E-02 pCVg (7.2) 12/26/03 01:58 p 335.7 GER5'(7.5) 9 CO-60 -1.22E-02 U 2.68E-02 2.68E-02 4.72E-02 pC/g -0.26 12/2610301:58 p 335.7 GERS'1.50E-01 -0.91 9 CS-134 3.60E-02 U 3.35E-02 3.35E-02 6.54E-02 pClg 0.55 12/26/0301:58 p 335.7 GER5'1.90E-01 (2.2) 9 CS-137 8.50E-03 U 3.24E-02 3.24E-02 5.90E-02 pC11g 0.14 12/2610301:58 p 335.7 GER5'3.20E-01 0.52 9 EU-152 1.20E-02 U 7.97E-02 7.97E-02 1.38E-01 pCVg 0.09 12/26/03 01:58 p 335.7 GERS!4.04E-01 0.3 3 EU-154 3.65E-02 U 8.24E-02 8.24E-02 1.60E-01 pCVg 0.23 12/26/03 01:58 p 335.7 GER5'3.70E-01 0.89 9 STL Richland rptSTLRchSample V4.05 A97-J P MDCIMDA.Le
-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efficency, Yield, and Volume.J Oual -No Uk< qualifier has been assigned and the result Is below the Reporting Umit, RL (CRDL) or Report Value Is Estimated.
U Oual -Analyzed for, but the result Is less than the Mde/MdalTootl Uncert or gamma scan software did not Identity the nuclide.
f I v I I I I f fI I I F I Par No. o'Lab Name: STL Richland Lot-Sample No.: J3L030207-17 Client Sample ID: 9537-0000-012F Result ameter Qual Err EU-155 3.84E-02 U 7.: K-40 1.06E+01 1 MN-54 -1.75E.03 U 2.'NB-94 2.1 OE-02 U 2.: PB.212 6.55E-01 1.: PB-214 7.35E-01 1.RA-226 6.48E-01 1.TL*208 2.64E-01 6.'ount'or( 2 s)?6E.02 FSE+O0 98E-02 36E-02 34E-01 63E-01 73E-01 44E.02 Total UncerX2 s)7.26E-02 1.75E+O0 2.98E-02 2.36E.02 1.34E01 1.63E-01 1.73E-01 6.44E-02 FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00242 MDCIMDA. Rpt UnIt. Yield Action Lev LC CRDL(RL)1 .26E-01 pCVg 1.57E+01 4.40E-01 pCVg 528E-02 pCVg 6.96E-O1 4.71 E-02 pCilg 2.85E-01 7.76E-02 pCVg 9.93E-02 pCltg 9.02E-02 pCVg 4.93E-02 pCVg Date: 30-Dec-03 RsMiDC, RstTotUcert 0.3 (1.1)(24.2)(12.2)-0.03-0.12 0.45 (1.8)(8.4)(9.8)(7.4)(9.)(7.2)(7.5)(5.3)(8.2)-Collection Date: 11/14/200310:57:00 AM Received Date: 12/1/2003 11:00:00AM Matrix: SOIL Ordered by Client Sample ID. Batch No Analysis.
Total Sa Aliquot Primar Prep Date Size Size Detectc 12126103 01:58 p 335.7 GER5!9 12/26/03 01:58 p 335.7 GER5!9 12/26/0301:58p 335.7 GER5!9 12/26t0301:58p 335.7 GER5!9 12/26t03 01:58 p 335.7 GER5!9 12/26/03 01:58 p 335.7 GER5'9 12/26/03 01:58 p 335.7 GER5'9 12/26/0301:58p 335.7 GER5'9 I Results: 18 Comments: STL Richland MDCIMDA.Lc
-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.rptSTLRchSample J Qual -No Ul< qualfier has been assigned and the result Is below the Reporting LImit, RL (CROL) or Report Value 1s Estimated.
V4.05 A97 U Qual -Analyzed for but the result Is less than the Mdc/MdalTotal Uncert or gamma scan sotware did not Identify the nuclide, N4 r** -r -r. ( ( (. ( (: .C. .I FORM I SAMPLE RESULTS Lab Name: STL Richland SDG; 24642 Lot-Sample No.: J3LO30207-18 Report No.: 24555 Client Sample ID: 9537-000O-0135 COC No.: 2003-00242 ( ' v'.. l .t ' C .Date: 30-Dec-03 Collection Date: 11/13/2003 10:55:00AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID. Batch No Result Count Total MDCIMDA. Rpt Unit, Yield Rst/MDC, Analysis.
Total Sa Aliquot Primar Parameter Qual Error( 2) Uncet(2 s) Action Lev Lc CRDL(RL) RstrTotUcert Prep Date Size Size Detect Bitch: 3339266 RICHRC5017 Work0rder F5XJIA1M ReportDBID:
9FSXIJ10 AC-228 7.102-01 1.84E-01 1.84E-01 1.57E-01 pCVg (4.5) 12/26/03 03:45 p 345.5 GERE (7.7) 9 AG-108M 4.49E-03 U 1.95E-02 1.95E-02 3.48E-02 pC/g 0.13 12/26103 03:45 p 345.5 GER8.2.86E-01 0.46 9 AM-241 -2,77E-02 U 5.36E-02 5.36E-02 8.77E-02 pCVg -0.32 12/26103 03:45 p 345.5 GER8: 1.03E+00 -(1.) 9 Bi.212 7.58E.01 U 4.10E-01 4.10E-01 8.11E-01 pCVg 0.93 12/26/0303:45p 345.5 GERS (3.7) 9 BP1214 5.992-01 1.26E-01 1.26E-01 7.55E-02 pCVg (7.9) 12/26/03 03:45 p 345.5 GER8 (9.5) 9 CO-60 1.042-02 U 2.71 E-02 2.71E-02 5.30E-02 pCVg 0.2 12/26/03 03:45 p 345.5 GERB 1.502-01 0.77 9 CS-134 1.04E-02 U 3.08E-02 3.08E.02 5.62E-02 pClg 0.19 12/26/0303:45 p 345.5 GER8B 1.90E-01 0.68 9 CS.137 2.64E-02 U 2.B0E-02 2.80E-02 5.33E-02 pCVg 0.5 12/26/03 03:45 p 345.5 GER8.3.20E-01 (1.9) 9 EU-152 1.08E.02 U 6.80E-02 6.80E-02 1.20E-01 pCVg 0.09 12126103 03:45 p 345.5 GER81 4.04E-01 0.32 9 EU-154 4.39E-02 U 7.83E-02 7.83E-02 1.55E-01 pCig 0.28 12/26103 03:45 p 345.5 GER8!3.70E-01 (1. 1) 9 STL Richland MDCIUDALc
-Detection, Decision Level based on Instrument background or blank, adjusted bythe sample Efficiency, Yield, and Volume.rptSTLRchSample J Cual -No U1< qualfier has been assigned and the resuit Is below the Reporting Limit, RL (CRDL) or Report Value Is Estimated.
V4.05 A97 U Dual -Analyzed for, but the result Is less than the MdlaMdalTotaI Uncert or gamma scan software did not Identity the nuclide.-.
r I I I I I I I. I I I Par No. of Lab Name: STL Rlchland Lot-Sample No.: J3L030207-18 Client Sample ID: 9537-0000-013F Result ameter Oual Errf EU- 155 6.87E-03 U 6.8 K-40 1.19E+01 1.7 MN-54 5.84E-03 U 2.(NB-94 5.21 E.03 U 2., PB-212 6.69E-01 1.E PB-214 6.65E-01 t.4 RA-226 5.99E-01 1.4 TL-208 2.33E-01 5.1-:ount Total or( 2s) Un cerg 2 s)19E-02 6.89E-02'85+00 1 .78E+00~4E-02 2.64E-02!7E-02 2.27E-02 34FE-01 1.34E-01 I8E-01 1 .48E-01 26E-01 1 .26E-01 23E-02 5.03E-02 FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00242 MDCIMDA. Rpt UnIt, Yield ActIon Lev Le CRDL(RL)1.19E-01 pCVg 1.57E+01 5.22E.01 pC/g 4.91E-02 pCVg 6.96E-01 4.26E-02 pCig 2.85E-01 8.56E-02 pCl/g 8.41 E.02 pCVg 7.55E-02 pCVg 4.68E-02 pCVg RsVMDC, RstTotUcert 0.06 0.2 (22.7)(13.3)0.12 0.44 0.12 0.46 (7.8)(10.)(7.9)(9.)(7.9)(9.5)(5.)(9.3)Dato: 30-Dec-03 Collection Date: 11/13/2003 10:55:00 AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID, Batch No.Analysis, Total Sa Aliquot PrImar Prep Date Size Size Detectc 12/26/03 03:45 p 345.5 GER81 g 12/26/03 03:45 p 345.5 GER8M 9 12/26/03 03:45 p 345.5 GER8'9 12/26/03 03:45 p 345.5 GER89 9 12/26/03 03:45 p 345.5 GER89 9 12/26/03 03:45 p 345.5 GER89 9 12t26/03 03:45 p 345.5 GER85 9 12/26/03 03:45 p 345.5 GER81 9 Results: 18 Comments: STL Rlchland MDCIMDALc
-Detection, Decislon Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.rptSTLRchSample J Qual -No Ul< quallfier has been assigned and the result Is below the Reporting Limit, RL (CRDL) or Report Value Is Estimated.
V4.05 A97 U Qual -Analyzed for, but the result Is less than the Mdc/MdalTotal Uncert or gamma scan software did not Identify the nuclide.-J 0t.
I r-I I I I I I (I I I I[ I FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00242 Date: 30-Dec-03 Collection Date: 11/13/2003 10:45:00AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Lab Name: STL Richiand Lot-Sample No.: J3L030207-19 Client Sample ID: 9537-0000-014F01 Ordered by Client Sample ID, Batch Nc Result Count Total MDCIMDA, Rpt Unit, Yield RsMtADC, Analysis, Total Sa Aliquot Primai Parameter Qual Error ( 2 s) Uncer(2 s) Action Lev Lc CRDL(RL) RsttTotUcert Prep Date Size Size Detecto Batch: 3339266 RICHRC5017 Work Order: FSXHM1AA Report DB ID: 9FSXHM10 AC-228 6.332-01 2.09E-01 2.09E-01 1.55E-01 pCi~g (4.1) 12/26/03 03:46 p 384.9 GER7 (6.1) 1 AG-108M 1.32E-03 U 1.86E-02 1.86E-02 3.34E-02 pCr/g 0.04 12/26/03 03:46 p 384.9 GER7 2.86E-01 0.14 9 AM-241 1.37E-02 U 8.78E-02 8.78E-02 1.49E-01 pCVg 0.09 12/26103 03:46 p 384.9 GER7.1.03E+00 0.31 9 Bl-212 4.42E-01 U 3.85E-01 3.85E-01 7.43E-01 pCVg 0.6 12/26/03 03:46 p 384.9 GER?.(2.3) 9 Bl-214 4.98E-01 U 1.38E-01 1.38E-01 1.87E-01 pCilg (2.7) 12126103 03:46 p 384.9 GER7: (7.2) g Co060 7.12E-03 U 2.48E-02 2.48E*02 4.84E-02 pCVg 0.15 12/26103 03:46 p 384.9 GER7: 1.50E-01 0.57 9 CS-134 4.72E-02 U 2.90E-02 2.90E-02 5.88E-02 pCVg 0.8 12/26/03 03:46 p 384.9 GER7: 1.90E-01 (3.3) 9 CS-137 6.40E-02 J 4.76E-02 4.76E-02 4.64E-02 pCVg (1.4) 12/26103 03:46 p 384.9 GER7: 3.20E-01 (2.7) 9 EU-152 -2.89E-02 U 6.47E-02 6.47E-02 1.08E-01 pCVg -0.27 12/26103 03:46 p 384.9 GER71 4.04E-01 -0.89 9 EU-154 -3.59E-02 U 7.34E-02 7.34E.02 1.27E-01 pCI/g -0.28 12/2610303:46 p 384.9 GER7 3.702-01 -0.98 9 STL Richuland rptSTLRchSample V4.05 A97 MOCjMDA.Lc
-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.J Qual -No UI< qualifier has been assigned and the result Is below the Reporting Limit, RL (CRDL) or Report Value Is Estimated.
U Qual -Analyzed for, but the result Is less than the Mdc/AdarTotal Uncert or gamma scan software did not Identify the nuclide.-3 ui
( r .(-r V -. .V: V I r V " U-FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00242 Lab Name: STL Richland Lot-Sample No.: J3L030207-19 Client Sample ID: 9537-0000-014F01 Parameter EU-155 K-40 MN-54 NB-94 PB-212 P8-214 RA-226 TL-208 No. of Results: 18 Result 4.05E.02 1.02E+01 4.18E-03 1.09E-02 7.11 E-01 5.42E-01 4.96E-01 1 .79E-01-Count Cual Error ( 2 s)U 7.21 E.02 1 .63E+00 U 2.92E-02 U 2.22E-02 1 .34E-01 1 .33E-01 1 .38E-01 U 5.25E-02 Total Unceht 2 s)7.21 E.02 l .63E+00 2.92E*02 2.22E.02 1 .34E-01 1.33EO01 1 .38E-01 5.25E-02 MDCIMDA, Rpt Unitt Action Lev Lc 1.28E-01 pCig 4.36E-01 pCVg 5.22E-02 pCi/g 4.28E-02 pCL/g 6.27E-02 pCVg 7.18E-02 pCVg 8.27E.02 pCVg 8.03E-02 pCVg Yield Rat/MDC, CROL(RL) RstirotUcert 0.32 1.57E+01 (1.1)(23.3)(12.5)0.08 6.96E-01 0.29 0.26 2.85E-01 0.99 (11.3)(10.6)(7.5)(8. 1)(6.)(7.2)(2.2)(6.8)-Date: 30-Dec-03 Collection Date: 11/13/2003 10:45:00 AM Received Date: 12/1/2003 11:00:00AM Matrix: SOIL Ordered by Client Sample ID, Batch No Analysis, Total Sa Aliquot Primar Prep Date Size Size Detectc 12/26/03 03:46 p 384.9 GER71 9 12/26/03 03:46 p 384.9 GER7: 9 12/26/03 03:46 p 384.9 GER7: 9 12/26/03 03:46 p 384.9 GER7'9 12/26/03 03:46 p 384.9 GER71 9 12/26/03 03:46 p 384.9 GER7: 9 12/26/03 03:46 p 384.9 GER7 9 12/26/03 03:46 p 384.9 GER7'9 Comments: STL Richiand MDCIJDA,Lc
- Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.rptSTLRchSample J Qual .No U1 quallfier has been assigned and the result Is below the Reporting Limit, RL (CRDL) or Report Value Is Estimated.
V4.05 A97 U Oual -Analyzed for, but the result Is less than the MdcMUdaiTotal Uncert or gamma scan software did not Identify the nuclide.o1 (Ai
( r El)H.(' -I ( ..I ( FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00242 Lab Name: STL Richland Lot-Sample No.: J3L030207-20 Client Sample ID: 9537-0000-014102 Date: 30-Dec-03 Collection Date: 11/13/2003 11:15:00AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID. Batch No.Result Count Total MDCjMDA, Rpt Unit, Yield Rst/MDC, Analysis, Total Sa Aliquot Primar Parameter Quas Error( 2s) Unceft(2 s) Action Lev Lc CRDL(RL) RsrTotUcert Prep Date Size Size Dctecte Batch: 3339266 RICHRC5O17 Work Order: F5XiR1AA Report DB ID: 9F5XHRI0 AC-228 4.67E-01 2.00E-01 2.00E-01 1.59E-01 pC1g (2.9) 12126/03 03:47 p 421.2 GER4!(4.7) g AG-108M 529E-03 U 1.96E-02 1.96E-02 3.48E-02 pCi/g 0. 15 12/26/03 03:47 p 421.2 GER4!2.86E-01 0.54 9 AM-241 9.17E-02 U 1.35E-01 1.35E-01 2.40E-01 pCI/g 0.38 12/26103 03:47 p 421.2 GER4!1.03E+00 (1.4) 9 81-212 1.56E+00 U 6.65E-01 6.65E-01 8.33E-01 pCi/g (1-9) 12/26/03 03:47 p 421.2 GER4t (4.7) 9 81-214 5.40E-01 U 1.21E-01 1.21E-01 1.77E-01 pC/g (3.) 12/26/0303:47p 421.2 GER4'(8.9) 9 CO-60 -1.65E.02 U 2.50E-02 2.50E-02 4.16E-02 pCLg -0.4 12/26/03 03:47 p 421.2 GER4'1.50E-01 -(1.3) 9 CS-134 3.10E-02 U 2.68E-02 2.68E-02 5.31E-02 pCVg 0.58 12(26/03 03:47 p 421.2 GER4!1.90E-01 (2.3) 9 CS-137 2.70E-02 U 2.93E-02 2.93E-02 5.41E-02 pCVg 0.5 12f26t03 03:47 p 421.2 GER4!3.20E-01 (1.8) 9 EU-152 -1.68E-02 U 6.21E-02 6.21E-02 1.07E-01 pC/g -0.16 12/26/0303:47 p 421.2 GER4!4.04E-01 -0.54 9 EU-154 -2.89E-02 U 8.07E-02 8.07E-02 1.40E-01 pCVg -0.21 12/26/03 03:47 p 421.2 GER4!3.70E-01 -0.74 9 STL Richland rptSTLRchSample V4.05 A97-.2 MDCIMDALc
-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.J Qual -No Uj< qualifier has been assigned and the result Is below the Reporting Limit, RL (CRDL) or Report Value Is Estimated.
U Qual -Analyzed for, but the result Is less than the Mdc/MdaITotal Uncert or gamma scan software did not identify the nucilde.
( ( c Lab Name: STL Richland Lot-Sample No.: J3L030207-20 Client Sample ID: 9537-0000-014F02 ( [I (FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003.00242 Parameter EU-155 K-40 MN-S4 NB-94 PB-212 PB-214 RA-226 TL-208 No. of Results: 18 Result Qual 2.20E-02 U 9.41 E+00 9.69E-03 U 4.79E-04 U 5.21 E-01 7.14E-01 5.40E-01 U 1.93E-01 U Comments: Count Error ( 2 s)7.42E.02 1 .47E+00 2.45E-02 2.09E-02 1.21 E-01 1.30E-01 1.21 E-01 6.07E-02 Total Uncert(2 s)7.42E-02 1 .47E+00 2.45E-02 2.09E-02 1.21 E-01 1.30E-01 1.21E-01 6.07E-02-MDC MDA, Rpt Unit, Yield Action Lev Lc CRDL(RL)1.31E-01 pC/g 1.57E+01 3.32E-01 pCVg 4.55E-02 pCIg 6.961-01 3.74E.02 pCIg 2.85E-01 8.15E-02 pCVg 7.64E-02 pCVg 1.77E-01 pCVg 8.42E-02 pCVg RstlMt RstVTotl 0.1 0.5 (28.(12.0.2 0.7-0.C-O.C (6.(9.(11 (3.(8.!(2.(6..(. ( ( ( ( (j. (Date: 30-Dec-03 Collectlon Date: 11/13/200311:15:00 AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID, Batch No DC, Analysls, Total Sa Aliquot Primar Ucert Prep Date Size Size DoetectU 7 12/26/03 03:47 p 421.2 GER4.9 9 4) 12/26/03 03:47 p 421.2 GER4: 8) 9 1 12/26/0303:47 p 421.2 GER4: ,9 3)I 12/26/03 03:47 p 421.2 GER4: 15 9 4) 12126/03 03:47 p 421.2 GER4: 9 4) 12/26103 03:47 p 421.2 GER4: 9) 12/26/03 03:47 p 421.2 GER4: 9J 9 3) 12/26/03 03:47 p 421.2 GER4: 4) 9 STL Richland MDCIMDALC
-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.rptSTLRchSompte J Oual
- No Ul qualifier has been assigned and the result Is below the Reporting Umit, RL (CRDL) or Report Value Is Estimated.
V4.05 A97 U Oual -Analyzed for, but the result Is less than the Mdc/Mdarotal Uncert or gamma scan sotware did not identify the nuclide.W r ( ((( ( (r ( r. ( f FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00243 Lab Name: STL Richland Lot-Sample No.: J3L030207-21 Client Sample ID: 9537-O000-015F Date: 30-Dec-03 Collection Date: 11/14/2003 10:58:00 AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID. Batch No.Result Count Total MDCIUDA, Rpt Unit, Yield Rs"DMOC, Analysis, Total Sa Aliquot PrImar2 Parameter Oual Error ( 2 s) Uncert 2 s) Action Lev Lc CRDL(RL) RstITotUcert Prep Data Size Size Detecto Batch: 3339266 RICHRC5017 WorkOrder:
F5XHX1M Report DB ID: 9F5XHX10 AC-228 6.72E-01 U 2.01E-01 2.01E-01 3.28E-01 pCVg (2.) 12/26/03 03:49 p 383.6 GER5'(6.7) 9 AG-108M 7.33E-03 U 1.97E-02 1.97E-02 3.60E-02 pCVg 0.2 12/26/03 03:49 p 383.6 GER5'2.86E-01 0.74 9 AM-241 6.43E-03 U 5.16E-02 5.16E-02 8.53E602 pCVg 0.08 12126103 03:49 p 383.6 GER5'1.03E+00 0.25 9 8l-212 1.39E+00 U 4.29E-01 4.29E-01 8.06E-01 pC!/g (1.7) 12/26/03 03:49 p 383.6 GER51 (6.5) 9 Bl-214 5.35E-01 1.28E-01 1.28E-01 8.42E-02 pCVg (6.3) 12/2610303:49 p 383.6 GER59 (8.3) 9 CO-60 -725E-03 U 2.40E-02 2.40E-02 4.33E-02 pCfg -0.17 12/26/03 03:49 p 383.6 GER51 1.50E-01 -0.6 9 CS-134 5.006-02 U 3.32E-02 3.32E-02 6.53E-02 pCVg 0.77 12/26/03 03:49 p 383.6 GER5'1.90E-01 (3.) 9 CS-137 2.34E-02 U 2.99E-02 2.99E-02 5.62E-02 pCVg 0.42 12126/0303:49 p 383.6 GER5S 3.20E-01 (1.6) g EU-152 1.12E-02 U 6.71 E-02 6.71 E-02 1.20E-01 pClg 0.09 12/26/03 03:49 p 383.6 GER53 4.04E-01 0.33 9 EU-1 54 -9.68E-03 U 7.27E-02 7.27E-02 1.30E-01 pClIg -0.07 12/26/0303:49 p 383.6 GER59 3.70E-01 0.27 9 STL Richland MDCIMDALc
-Detection, Decision Level based on instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.rptSTLRchSample J -ual No Ul< qualifier has been assigned and the resut Is below the Reporting Limit, RL (CRDL) or Report Value Is Estimated.
V4.05 A97 U Oual -Analyzed for, but the result Is less than the Mdc/MdalTotal Uncert or gamma scan software did not Identity the nuclide.'.
I ( r ( I ( I *C Pan No. of Lab Name: STL Richland Lot-Sample No.: J3L030207-21 Client Sample ID: 9537-0000-015F Result Imeter Cual Err EU- 155 -1.77E-02 U 6.5 K-40 8.95E+00 1.4 MN-54 -4.73E-03 U 2.6 NB-94 -1.38E.02 U 2.4 PB-212 5.61E401 1.PB-214 6.29E-O1 1.c RA-226 5.35E-01 1.: TL-208 2.55E-01 5.':ount or ( 2 s);9E-02 8E+00 W0E-02!6E-02?OE-01 50E-01 M8E-01 52E-02 Total Uncerg 2 5)6.59E-02 1.48E-00 2.60E-02 226E-02 1.20E-01 1.60E-01 1 .28E-01 5.52E-02-FORM I SAMPLE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00243 MDCjMDA, Rpt Unit, Yield RsOWII Action Lev Lc CRDL(RLJ RsttTotU 1.11E-01 pCVg *O.li 1.57E+01 -0.5w 3.58E-01 pCVg (25., (12.1 4.56E-02 pCVg -0. 1 6.96E-01 -0.3 3.75E-02 pCVg -0.3 2.85E-01 fJ1.Z 6.77E-02 pCVg (8.3 (9.4 7.57E-02 pCVg (8.3 (8.4 8.42E-02 pCVg (6.3 (8.3 4.52E-02 pCVg (5.6 (9.;?I 1 I ( 1 Date: 30-Dec.03 Collection Date: 11/14/200310:58:00 AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Ordered by Client Sample ID, Batch No 0C, Analysis, Total Sa Aliquot Primar Jcert Prep Date Size Size Detect(6 12/26/03 03:49 p 383.6 GERS) 12/26/03 03:49 p 383.6 GERS: r) 9 12/26/03 03:49 p 383.6 GERS: 6 9 7 12/26/03 03:49 p 383.6 GER5: Z) 9) 12/26/03 03:49 p 383.6 GER5!9) 12126/03 03:49 p 383.6 GER5'f) 9 12/26/03 03:49 p 383.6 GER5'R) 9 12126/03 03:49 p 383.6 GER51?) 9 Results: 18 Comments: STL Richland MDCiMDALc
-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.rptSTLRchSampIe J Qual -No UI< qualifier has been assigned and the result Is below the Reporting Umil, RL (CROL) or Report Value Is Estimated.
V4.05 A97 U Qual -Analyzed for, butthe result Is Iess than theMdc/MdalTotaI Uncertorgamma scan software did rot Identifythenuclide.
00 C)
(r (* ( ( ( I I (F r r I ( ( I(FORM 11 DUPLICATE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003.00241 Date: 30-Dec-03 Collection Date: 11/14/2003 10:45:00 AM Received Date: 12/1/2003 11:00:00 AM Matrix: SOIL Lab Name: STL Richland Lot-Sample No.: J3L030207*1 ClIent Sample ID: 9537-0000-001 F DUP Result, Count Total MDCIMDA, Rpt Unit, Rct/MDC, Analysis, Total &a Aliquot Primary Parameter Orig Rst Cual Error (2 a) Uncert(2 s) Action Lev CRDL Yeld Rst/TotUert Prep Date Size Sizo Detector Batch: 3339264 RICHRC5017 WorkOrder:
F5XFGIAC Report D5 ID, F5XFG1CR OrigSaDB ID: 9FSXFG10 AC-228 7.08E-01 1.97E-01 1.97E-01 1.83E-01 pCVg (3.9) 12/25/03 12:34 p 377.0 GER7$1 6.07E-01 RER2 0.7 (7.2) 9 AG.108M -923E-03 U 1.96E-02 1.96E-02 3.32E-02 pCVg -0.28 12/25/03 12:34 p 377.0 GER7S1-1.30E-03 U RER2 0.6 2.86E-01 -0.94 9 AM-241 3.02E-02 U 8.92E-02 892E-02 1.56E-01 pCVg 0.19 12/25/03 12:34 p 377.0 GER7$1 2.31 E-02 U RER2 0.1 1.03E+00 0.68 g 81-212 8.68E-01 U 4.38E-01 4.38E-01 8.62E-01 pCVg (1-) 12125/03 12:34 p 377.0 GER7S1 1.01E+00 U RER2 0.3 (4.) 9 Bl-214 8.17E-01 1.59E-01 1.59E-01 8.75E-02 pCVg (9.3) 12/25/03 12:34 p 377.0 GER7$1 7.39E-01 RER2 0.7 (10.3) g CO-e0 2.23E-02 U 2.74E-02 2.74E-02 5.62E-02 pClg 0.4 12/25/03 12:34 p 377.0 GER7$1-1.19E-02 U RER2 1.9 1.50E-01 (1.6) 9 CS-134 3.01 E-02 U 2.90E-02 2.90E-02 5.74E 02 pCi/g 0.52 12/25/03 12:34 p 377.0 GER7S1 3.52E-02 U RER2 0.3 1.90E-01 (2.1) 9 CS-137 6.33E-02 J 3.80E-02 3.80E-02 5.42E-02 pCl/g (1.2) 12/25103 12:34 p 377.0 GER7$1 8.33E-02 J RER2 0.8 3.20E-01 (3.3) 9 EU-152 -5.52E-02 U 6.64E-02 6.64E-02 1.06E-01 pCVg -0.52 12/25/03 12:34 p 377.0 GER7S1.2.54E-02 U RER2 0.6 4.04E-01 -(1.7) 9 EU-154 -7.75E-02 U 9.16E-02 9.1 6E-02 1.46E-01 pCVg -0.53 12/25/03 12:34 p 377.0 GER7S1 6.08E-03 U RER2 1.4 3.70E-01 -(1.7) 9 EU-155 3.27E-02 U 7.83E-02 7.83E-02 1.34E-01 pClg 0.24 12/25/03 12:34 p 377.0 GER7$1 1.56E-02 U RER2 0.3 1.57E+01 0.83 9 STL Richlarnd rptSTLRc~hDupV4.0 5 A97 RER2 .Replicat Error Ratio -(S.Dy[sqrt(.s 9 (xpu4+sq(rPUd))
as deflned by ICPI BOA.MDCIMDA,Lc
.Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efliciency, Yield, and Volume.I Qual -No Ut. qualifier has been assigned and the rslt is below the Reporting Limit, RL (CRDL) or Report Value Is Estimated.
U Qual -Analyzed for, but the result Is less than the MdcMdalTotal Unceft or ganmnu scan software did not Identify the nudide.
r ..I 1 t .I I I r I .I I f Par No.c Lab Name: STL Richland Lot-Sample No.: J3L030207-1 Client Sample ID: 9537-0000-001F DUP Result, Co ameter Orig Rst auzl Error K-40 1.11E+01 1.74 1.03E+01 MN-54 2.03E-02 U 2.7!-1.96E-02 U NB-94 *6.93E-03 U 2.51-2.36E-02 U PB-212 6.89E-01 1.3: 6.35E-01 PB-214 7.96E-01 1.7, 8.21E-01 RA-226 8.17E-01 1.5 7.39E-01 TL-208 2.81 E-01 6.0 2.48E-01 ouint Total (2') UDcert(2S) 4+00 1.74E+00 RER2 0.7 SE-02 2.75E-02 RER2 2.1)E-02 2.59E-02 RER2 0.9 3E-01 1.33EI01 RER2 0.6 r4E-01 1.74E-01 RER2 0.2 9E-01 1.59E-01 RER2 0.7 3E-02 6.03E-02 RER2 0.7 unt Total FORM 11 DUPLICATE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00241 MDCIMDA, Rpt Unit, RstAh Action Lev CRDL Yield RsftTo 5.23E-01 pCVg (21 (12 5.30E-02 pCVg O.6.96E;01 (1I 4.51E-02 pCVg -0.2.85E-01 °0.6.69E-02 pCVg (1C (iC 8.29E.02 pCVg (9 (9 8.76E-02 pCVg (9 (l(4.22E-02 pCVg t6 ,.Collection Date: Received Date: Matrix: MDC, IUcert.3)!.8)38.5).15 54 0.3)).4).6).2)9.3)1.3)6.6)9.3)Analysis, Prep Date 12/25/03 12:34 p 12/25/03 12:34 p 12/25/03 12:34 p 12/25103 12:34 p 12/25/03 12:34 p 12/25/03 12:34 p 12/25/03 12:34 p Date: 30-Dec-03 I 1114/2003 10:45:00 AM 12/1/2003 11:00:00 AM SOIL Total S Size a Aliquot Primary Size Detcctor 377.0 GER7$1 g 377.0 GER7S1 377.0 GER7S1 9 377.0 GER7$1 9 377.0 GER7S1 9 377.0 GER7$1 9 377.0 GER7S1 9)f Results: 18 Comments: STL Richland RER2 .Replicate Error Ratio = (S.DYtsgrt(sqrPUs%-q(TPUd))1 an defined by ICPT BOA.rptSTLRchDupV4.0 MDCLJIDALC Dettction, DclsIou Level based on Instinueut badcground or blank, adjutd by the sample Eficiency.
Yield, and Volume.5 A97 U Qual .Analyzed for, but the result Is less than the MddMdarotal Uncert or gammra scan software did not Identify the nudide.CO
( f. f 17. ( ( 17 F .( ,'-3 tI H r FORM 11 Date: 30-Dec-03 DUPLICATE RESULTS Lab Name: STL Richland SDG: 24642 Collectlon Date: 11/13/2003 2:25:00 PM Received Date: 12/1/2003 11:00:00 AM Lot-Sample No.: J3L030207-15 Client Sample ID: 9537-0000011F01 DUP Report No.:. 24555 COC No.: 2003-00242 Matrix: SOIL Result, Count Total MDC)MDA, Rpt Unit, RsttMDC, Analysis, Total Sa Aliquot Primary Parameter Orig Rst ual Error (2 r) Uncerit 2 s) Action Lev CRDL Yield RStrotUcert Prep Date Size Size Detector Batch: 3339268 RICHRC5017 WorkOrder F5XHDIAC Report DB ID: F5XHD1CR Orfg Sa 0 ID: 9F5XHD10 AC-228 5.28E-01 U 1.78E-01 1.78E-01 2.88E-01 pCVg (1.8) 12J26/03 03:45 p 333.8 GERS$1 5.79E-01 U RER2 0.4 (5.9) 9 AG-108M 1.9112-03 U 2.12E-02 2.12E-02 3.69E-02 pCVg 0.05 12/26103 03:45 p 383.8 GER6$1 7.43E-03 U RER2 0.4 2.86E-01 0.18 9 AM-241 4.71 E-02 U 7.38E-02 7.38E-02 1.252-01 pCVg 0.38 12/26/03 03:45 p 383.8 GER6$1-6.98E-02 U RER2 2.0 1.03E+00 (1.3) 9 Bl 212 7.73E-01 U 4.52E-01 4.52E-01 7.44E-01 pCI/g (1.) 12/26/03 03:45 p 383.8 GER6S1 4.34E-01 U RER2 1.2 (3.4) 9 81-214 4.292-01 U 1.14E-01 1.14E-01 1.76S-01 pCVg (2.4) 12/26/03 03:45 p 383.8 GER6$1 4.88E-01 U RER2 0.7 (7.5) g CO-60 -8.01E-03 U 2.71E-02 2.71 E-02 4.80E-02 pCVg -0.17 12/26/03 03:45 p 383.8 GER6$1-1.04E-02 U RER2 0.1 1.50E-01 -0.59 9 CS-134 4.44E-02 U 3.06E-02 3.06E-02 6.07E-02 pCVg 0.73 12/26/03 03:45 p 333.8 GER6$1 2.54E-02 U RER2 0.9 1.90E-01 (2.9) 9 CS-137 3.1OE-02 U 2.67E-02 2.67E-02 5.15E-02 pCVg 0.6 12/26/03 03:45 p 383.8 GER6S1 3.38E-02 U RER2 0.1 3.20E-01 (2.3) 9 EU-152 -4.07E-02 U 6.57E-02 6.57E-02 1.10E-01 pCig -0.37 12/26/03 03:45 p 383.8 GER6S1-2.12E-02 U RER2 0.4 4.04E-01 -(1.2) 9 EU.154 4.442-02 U 9.03E-02 9.03E-02 1.72E-01 pCVg 0.26 12126/03 03:45 p 383.8 GER6S5 4.79E-02 U RER2 0.1 3.70E-01 0.98 g EU-155 5.46E.02 U 6.19E-02 6.19E-02 1.08E-01 pCVg 0.5 12/26/03 03:45 p 383.8 GER6S1 2.82E-02 U RER2 0.6 1.57E+01 (1.8) 9 STL Richland RERZ .Rrplicte Error Ratio = (S.D~sqrsq(TPUs+sq(TpUd))
as dened by ICPT BOA.rptSTLRchDupV4.0 M)CJMDA.Lc
-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.5 A97 U Qual -Analyzed for, but the result Is less than the Mdd.MdajTotal Uncert or gama scan software did not Identify the nudide.
(' .I ..[ -C (I ( ( C C Lab Name: STL Richland Lot-Sample No.: J3L030207-15 Client Sample ID: 9J37-0000-011FO1 DUP Resul Parameter Orlq R K-40 8.12E-1.05E-MN-54 *1.24E 1.41E-N8-94 *5.21E 1.43E PB-212 4.84E 5.01E PB-214 6.29E 5.542 RA-226 4.29E 4.88E TL-208 1.52E 2.04E No. of Results: 18 Comments: t+00 i-01 E-02-02 E-03-02-01-01-01_-01_ 01'-01 0 Count Total ual Error (2 s) Uncert(2 s)1.42E+00 1.42E+00 RER2 2.2 U 2.88E-02 2.88E-02 U RER2 1.3 U 2.28E-02 2.28E-02 U RER2 1.2 1.07E-01 1.07E-01 RER2 0.2 1.38E-01 1.38E-01 RER2 0.8 1.14E101 1.14E-01 RER2 0.7 5.42E-02 5.42E-02 RER2 1.4-FORM If DUPLICATE RESULTS SDG: 24642 Report No.: 24555 COC No.: 2003-00242 MDCIMDA, Rpt Unit, Rst/M Action Lev CRDL Yield RstiTot 2.30E-01 pCVg (35 (11 4.93E-02 pCi/g -0..6.96E-01 -0.-4.02E-02 pCig -0.2.85E-01 -0..6.17E-02 pCVg (7.(9 8.282-02 pC/g (7.(9.8.25E-02 pCVg (5.(7.4.14E-02 pCVg (3 (5-MDC, tucert.3).5)25 86 13 46.8)9-).6).1).2).5).7).6)-Collection Date: Received Date: Matrix: Date: 30-Dec-03 Analysis, Prep Date 12/26/03 03:45 p 12/26/03 03:45 p 12/26103 03:45 p 12/26/03 03:45 p 12/26/03 03:45 p 12/26/03 03:45 p 12126/03 03:45 p 11/1312003 2:25:00 PM 12/1/2003 11:00:00 AM SOIL Total S Size a Aliquot Primary Size Detector 383.8 GER6S1 9 383.8 GER6$1 9 383.8 GER6S1 g 383.8 GER6$1 9 353.8 GER6S1 9 383.8 GER6$1 9 383.8 GER6S$1 9 STL Richland RER2 -Replicate Error Ratio = (S.DV[sqrt(sq/TPUs)+sq(rPUd))J as defined by lCPT BOA.rptSTfRchDupV4.0 MDCrWDA,Lc
-Detection, Decision Level based on Instrunent background or blank, adjusted by the sample Effidency, Yield, and Volume.5 A97 U Qual -Analyzed tor, but the result Is less than thc Mde/MdarTotal Uncert or gamma scan software did not Identify the nudide.co
(-- -.-_ t .-r -.( ' I -I .f'( r ( ( V FORM 11 Date: 30-Dec-03 BLANK RESULTS Lab Name: STL Richiand Matrix: SOIL SDG: 24642 Report No.: 24555 Count Total MDCIUDA, Rpt Unit, RSt/MDC, Analysis, Total Sa Aliquot Primary Parameter ResulS Qual Error (2 s) Uncer( 2 ) Lc CRDL Yield Rst/TotUcert Prep Date Size Size Detector Batch: 3339264 RICHRC5017 WorkOrder:
F53TWIAA Report DO ID: F53TWIAB AC-228 *5.46E-03 U 9.58E-02 9.58E-02 1.83E-01 pCVg -0.03 12/26/03 06:52 a 200.0 GER8$1-0.11 9 AG-108M .5.44E-03 U 1.98E-02 1.98E-02 3.49E-02 pCig -0.16 12/26/0306:52 a 200.0 GER8$1-0.55 9 AM-241 1.25E-02 U 3.69E-02 3.69E-02 5.82E-02 pCVg 0.21 12/26103 06:52 a 200.0 GERBS1 0.68 9 Bl-212 -3.03E-01 U 2.70E-01 2.70E-01 3.71 E-01 pCVg -0.82 12/26103 06:52 a 200.0 GER8$1-2.2) 9 Bl-214 1.962-04 U 5.55E-02 5.55E-02 1.17E-01 pCVg 0. 12126103 06:52 a 200.0 GER8$1 0.01 9 Co-60 7.85E 03 U 2.34E-02 2.34E-02 5.26E-02 pCVg 0.15 12/26/03 06:52 a 200.0 GER8S1 1.52E-01 0.67 9 CS-134 1.82E-02 U 2.87E-02 2.87E-02 5.98E-02 pCVg 0.3 12/26/03 06:52 a 200.0 GER8$1 1.87E-01 (1.3) 9 CS-137 2.84E.03 U 2.20E-02 2.202-02 4.35E-02 pCVg 0.07 12126103 06:52 a 200.0 GER8$1 3.16E-01 0.26 9 EU-1 52 4.942-02 U 7.28E-02 7.282-02 1.40E-01 pCVg 0.35 12126/03 06:52 a 200.0 GER8$1 4.04E-01 (1.4) 9 EU-154 2.32E-02 U 8.44E-02 8.44E-02 1.76E-01 pCVg 0.13 12126103 06:52 a 200.0 GER8S1 3.72E-01 0.55 9 EU-155 -3.34E-02 U 4.64E-02 4.64E-02 7.75E-02 pCVg -0.43 12126J03 06:52 a 200.0 GER8$1 1.57E+01 -(1.4) 9 K-40 1.25E201 U 4.47E-01 4.47E-01 9.20E-01 pCVg 0.14 12/26/03 06:52 a 200.0 GER851 0.56 9 STL Richland rptSTLRchBlank V4.05 A97 co Ln MDCIMDA.Lc
-Detection, DecisIon Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.U Qual -Analyzed ror, but the resut is less man the MddMdajdotaI Uncert or gamma scan software did not Identity the nudide.
(l* V ( (- (:* (*'-3 Hl Lab Name: STL Richland Matrix: SOIL ( ' r -(Date: 30-Dec-03 FORM 11 BLANK RESULTS SDG: 24642 Report No.: 24555 Count Total mDCjMDA. Rpt Unit, RstlMDC, Analysis, Total Sa Aliquot Primary Parameter Result Cual Error ( 2 a) Uncerg 2 s) L CRDL Yield RauTotUcert Prep Date Size Size Detector MN-54 -8.15E-03 U 2.81E-02 2.B1E-02 5.11E-02 pCIg -0.16 12/26103 06:52 a 200.0 GERSS1 6.96E-01 -0.58 9 NB-94 *6.25E-04 U 2.55E-02 2.55E402 4.90E-02 pCVg -0.01 12/26/03 06:52 a 200.0 GER8S1 2.85E-01 -0.05 9 PB-212 1.44E-02 U 3.94E-02 3.94E-02 7.36E-02 pCVg 0.2 12126/03 06:52 a 200.0 GER8$1 0.73 9 PB-214 -1.27E-01 U 5.83E-02 5.83E-02 8.78E-02 pCVg -(1.4) 12/26/03 06:52 a 200.0 GER8$1*(4.3) 9 RA-226 3.44E-05 U 5.54E-02 5.54E-02 1.17E-01 pCVg 0. 12/26/03 06:52 a 200.0 GER8$1 0. 9 TL-208 *2.60E.03 U 2.89E-02 2.89E-02 5.28E-02 pClg -0.05 12/26103 06:52 a 200.0 GER8S1-0.18 9 Batch: 3339266 RICHRC5017 WorkOrder:
F53VMlM ReportnDB ID: F53VMIAB AC-228 3.14E-02 U 9.18E -02 9.18E-02 1.88E-01 pCig 0.17 12/26/03 08:19 p 200.2 GER8S1 0.68 9 AG-108M 2.07E-02 U 2.36E-02 2.36E-02 4.68E-02 pCVg 0.44 12/26/03 08:19 p 200.2 GER8$1 (1.8) 9 AM-241 -1.61E-02 U 3.71E-02 3.71E-02 6.20E-02 pCVg -0.26 12(26/03 08:19 p 200.2 GER8$1-0.87 9 Bl-212 8.41E-02 U 4,OOE-01 4.OOE-01 7.65E-01 pCVg 0.11 12/26/03 08:19 p 200.2 GER8S1 0.42 9 81-214 -2.89E-02 U 6.25E-02 6.25E-02 1.22E-01 pCVg -0.24 12/26/03 08:19 p 200.2 GER8$1-0.93 9 CO-60 -3.76E-03 U 3.18E-02 3.18E-02 6.13E-02 pCVg -0.06 12/26/0308:19 p 200.2 GER8S1 11.52E-01
-0.24 9 STL Rlchland MDCJMDALc
-Detectfon.
Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.rptSTLRchd8ank U Qual -Analyzed for, but the result is le"s than the MddIMdalTotal Unecrt or itamua scan software did not Identify the nudide.V4.0S A97 CD an I ( C. ( ( ' 1. ( : *.I ( -I (. .I f ". ' ( -'FORM 11 BLANK RESULTS Date: 30-Dec-03 SDG: 24642 Report No.: 24555 Lab Name: STL Richland Matrix: SOIL Count Totd MDCIMDA, Rpt Unit, Rst/MDC, Analysis, Total Sa Aliquot Primary Parameter Result Qual Error ( 2 5) Uncert 2 s) Lc CROL Yield RsUTotUcert Prep Date Size Size Detector CS-134 9.31E-03 U 2.41E-02 2.41E-02 5.03E-02 pCVg 0.19 12/26/03 08:19 p 200.2 GER8S1 1.87E-01 0.77 9 CS-IS7 -1.56E-02 U 2.60E-02 2.60E-02 4.39E.02 pCVrg 0.36 12/26/03 08:19 p 200.2 GER8$1 3.16E-01 [(1.2) 9 EU-152 3.61 E-03 U 7.22E-02 7.22E-02 1.31E-01 pCVg 0.03 12/26/03 08:19 p 200.2 GER8$1 4.04E-01 0.1 9 EU-154 -2.69E-02 U 7.66E-02 7.66E-02 1.42E-01 pCVg .0.19 12/26/03 08:19 p 200.2 GER8S1 3.72E-01 *0.7 9 EU-1S5 1.39E-03 U 5.43E-02 5.43E-02 9.73E-02 pCVg 0.01 12/26/0308:19 p 200.2 GER8$1 1.572+01 0.05 9 K.40 -2.13E-01 U 3.39E-01 3.39E-01 6.53E-01 pCLg .0.33 12/26/03 08:19 p 200.2 GER8S1*(1.3) g MN-54 -1.48E-02 U 2.60E-02 2.60E.02 4.51E-02 pCVg -0.33 12/26103 08:19 p 200.2 GER8S1 6.96E-01 -(1.1) 9 NB-94 -6.56E-03 U 2.42E-02 2.42E-02 4.48E-02 pCVg -0.15 12/26/03 08:19 p 200.2 GER8S1 2.85E-01 -0.54 9 PB-212 -7.65E204 U 3.89E-02 3.89E-02 7.06E-02 pCVg -0.01 12/26/03 08:19 p 200.2 GER8S1-0.04 9 PB-214 -6.86E202 U 5.92E-02 5.92E-02 1.03E-01 pC/g -0.67 12/26/03 08:19 p 200.2 GER8S1-(2.3) 9 RA-226 -2.88E-02 U 6.25E-02 6.25E-02 1.22E-01 pCVg -0.24 12/26/03 08:19 p 200.2 GER8$1-0.92 9 TL-208 -1.03E-02 U 2.64E-02 2.64E-02 4.65E-02 pCVg -0.22 12/26/03 08:19 p 200.2 GERaSI-0.78 9-sIL Rlcnfand MLJGIMDALc
-DetecUon, Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.rptSTLRchBlank U Qual -Analymed for, but the result Is tess than the Mdd6datTot:-l Untert or ganuna scan software did not Identify the nuelide.V4.05 A97 co
-3 L H Lal t .(F -I?(. (.4 ( ..I .f. .Ij, ( f I ' ' ' I FORM 11 Date: 30-Dec*03 BLANK RESULTS b Name: Matrix: STL Richland SOIL SDG: 24642 Report No.: 24555 Count Total MDCIMDA, Rpt Unit, Rst/MDC, Analysis, Total Sa AlIquot Primary Parameter Result Qual Error ( 2 3) Uncert 2 s) Lc CROL Yield Rst/TotUcert Prep Date Size Size Detector No. of Results: 3B Comments: STL Rlchland rptSTLRch9lank V4.05 A97 MDCIMDA,Lc
-Detection, Decision Level based an Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.
.( L- t t I I I.' I: I f I FORM 11 LCS RESULTS Date: 30-Dec-03 Lab Name: STL Richland Matrix: SOIL SDG: 24642 Report No.: 24555 Count Total Report Expected Recowey, Analysis, Aliquot Primary Parameter Result Oual Error (2 s) Uncert(2 s) MDCIMDA Unit Yield Expected Uncert Bias Prop Oate Size Detector Batch: 3339264 RICHRC5017 WorkOrder:
F53TWlAC Report DB ID: F53TWICS CS.137 1.21E+00 2.0tE-01 2.01E-01 4.93E-02 pC/g 1.02E+00 3.56E-02 118% 12126/03 08:37 a 200.0 GER8$1 Rec Unimts: 70 130 0.2 9 Batch: 3339266 RICHRC5017 WorkOrder F53VM2AC Report DBID: F53VM2CS CS-137 1.25E+00 2.03E-01 2.03E-01 4.82E-02 pCi/g 1.02E+00 3.55E-02 122% 12/29/03 02:40 p 200.0 GE88$1 Rec Umits: 70 130 0.2 9 No. of Results: 2 Comments: STL Richlmnd ias -(ResultExpected)-1 as dcJfned by ANSI N1330.rptSTLRchLcs V4.05 A97 co 0o PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD Attachment 2b Hard-To-Detect Data (31 Pages)
..I- ezi&a ,)/I I (0 Analytical Data Package Prepared For Connecticut Yankee Radiochemical Analysis By STL Richland 2800 G.W. Way, Richland Wa, 99352, (509J-375-3131.
Assigned Laboratory Code: STLR Data Package Contains 31 Pages Report No.: 24916 SDG No. Order No. Client Sample ID (List Order)Lot-Sa No.24921 9536-0000-012F (F5XD7)9536-0000-012F (F5XD7)9536-0000-012F (FSXD7)9536-000G-012F (FSXD7)9536-0000-012F (F5XD7)9536-0000-012F (FSXD7)9536-0000-012F (F5XD7)9536-0000-012F (F5XD7)9536-0000-012F (F5XD7)9536-000013F (F5XD8)9536-0000-013F (F5XD8)9536-0000-013F (F5XD8)9536-0000-013F (FSXD8)9536-0000-013F (F5XD8)9536-0000-013F (F5XD8)9536-000a-013F (F5XD8)9536-0000-013F (F5XD8)9536-0000-013F (FSXD8)9537-0000-OQ0F (FSXFG)9537-0000-001F (F5XFG)9537-0000-001 F (FSXFG)9537-0000-O01F (F5XFG)9537-OO0O-001 F (F5XFG)9537-0000-001 F (F5XFG)9537-0000-001 F (F5XFG)9537-0000-001 F (F5XFG)J4A080282-1 J4A080282-1 J4A080282-1 J4A080282-1 J4A080282-1 J4A080282-1 J4A080282-1 J4A080282-1 J4A080282-1 J4A080282-2 J4A080282-2 J4A080282-2 J4A080282-2 J4A080282-2 J4A080282-2 J4A080282-2 J4A080282-2 J4A080282-2 J4A080282-3 J4A080282-3 J4A080282-3 J4A080282-3 J4A080282-3 J4A080282-3 J4A080282-3 J4A080282-3 Work Order F7PRF1AK F7PRFIAE F7PRF1AF F7PRF1AG F7PRF1AH F7PRF1AC F7PRF1AJ F7PRF1AD F7PRF2AA F7PTD1AK F7PTD1AE F7PTD1AF F7PTD1AG F7PTD1AH F7PTD1AC F7PTD1AJ F7PTD1AD F7PTD2AA F7PTH1AK F7PTHIAE F7PTH1AF F7PTH1AG F7PTH1AH F7PTH1AC F7PTH1AJ F7PTHlAD Report DB ID 9F7PRF10 9F7PRFI0 9F7PRF10 9F7PRF10 9F7PRF10 9F7PRF10 9F7PRFI0 9F7PRF10 9F7PRF20 9F7PTD10 9F7PTD10 9F7PTD10 9F7PTD10 9F7PTDI0 9F7PTD10 9F7PTD10 9F7PTDI0 9F7PTD20 9F7PTHI0 9F7PTH10 9F7PTH10 9F7PTH10 9F7PTH10 9F7PTH10 9F7PTH10 9F7PTH10 Batch No.4012334 4012336 4012337 4012340 4012341 4012343 4012345 4012347 4022536 4012334 4012336 4012337 4012340 4012341 4012343 4012345 4012347 4022536 4012334 4012336 4012337 4012340 4012341 4012343 4012345 4012347 Rwlchland TLRrhTite v3.73 1 Report No.: 24916 LDG No.Order No. Client Sample ID (List Order)Lot-Sa No.Work Order Report DB ID Batch No.24921 9537-0000-001 F (F5XFG)9537-0000-014F01 (F5XHM)9537-0000-014F01 (F5XHM)9537-0000-014FOl (F5XHM)9537-0000-014F01 (F5XHM)9537-0000-014F01 (F5XHM)9537-0000-014F01 (F5XHM)9537-0000-014F01 (F5XHM)9537-0000-014F01 (F5XHM)9537-0000-014F01 (F5XHM)J4A080282-3 J4A080282-4 J4A080282-4 J4A080282-4 J4A080282-4 J4A080282-4 J4A080282-4 J4A080282-4 J4A080282-4 J4A080282-4 F7PTH2AA F7PTJ1AK F7PTJ1 AE F7PTJ1 AF F7PTJ1 AG F7PTJ1 AH F7PTJ1AC F7PTJ1 AJ F7PTJ1AD F7PTJ2AA 9F7PTH20 9F7PTJ10 9F7PTJ10 9F7PTJ10 9F7PTJ10 9F7PTJ10 9F7PTJ1 0 9F7PTJ10 9F7PTJ10 9F7PTJ20 4022536 4012334 4012336 4012337 4012340 4012341 4012343 4012345 4012347 4022536.Richland'_kchfr1Ue v3.J3 2 M M I 1 s r STL Richland 2800 George Washington Way RMhlandWA 99352 Certificate of Analysis Tel:509375 3131 Fax: 509 375590 wwwsdinc~cor Connecticut Yankee Atomic Power Company 362 Injun Hollow Road East Hampton. CT 06424 February 16, 2004 Attention:
Pete Hollenbeck Date Received in Lab January 7, 2003 NumberofSamples
- Four(4)SDGNumber
- 24921 Project Name/Number Haddam Neck Decommissioning COC Number 2003-00239, 241, 242 Purchase Order Number : 002133 LTP QA ILSR 04-0307 CASE NARRATIVE I. Introduction On January 7, 2004, STL-Richland received a request to analyze four soil samples that had already been received at the STL Richland (STLR) laboratory.
Upon receipt, the samples were assigned the STLR identification numbers as described on the cover page of the Analytical Data Package report form. The samples were assigned to Lot Number J4A080282.
II. Sample Receipt-The samples were received in good condition and no anomalies were noted during check-in.III. Analytical Results/Methodology The analytical results for this report are presented by laboratory sample ID. Each set of data includes sample identification information, analytical results and the appropriate associatedstatistical errors.The requested analyses were: Alpha Spectroscopy Americium-241 by method RICH-RC-5080 Curium-243/244 by method RICH-RC-5080 Plutonium-238, -239/240 by method RICH-RC-5010 Gas Proportional Counting Strontium-90 by method RICH-RC-5006 i i I I i I 1, I I I I`I.i I 3.
Connecticut Yankee Atomic Power Company February 16, 2004 Page 2 Liquid Scintillation Counting Carbon-14 by method RICH-RC-5022 Iron-55 by method R.ICH-RC-5074 Nickel-63 by method RICH-RC-5069 Plutonium-241 by method RICH-RC-5010 Technetium-99 by method RICH-RC-507S Tritium by method RICH-RC-5037 IV. Quality Control The analytical result for each analysis performed includes a minimum of one laboratory control sample (LCS), and one reagent blank sample analysis.
Any exceptions have been noted in the "Comments" section.QC and sample results are reported in the same units.V. Comments Americiurn-241 by method RICH-RC-5080:
The LCS, batch blank, sample and sample duplicate results are within acceptance limits.Curium-243/244 by method RICH-RC-5080:
The LCS, batch blank, sample and sample duplicate results are within acceptance limits.Plutonium-238.
-2391240 by method RICH-RC-50 10: The LCS, batch blank, sample and sample duplicate results are within acceptance limits.Strontium-90 by method RICH-RC-5006:
Samples 9536-0000-013F, 9537-0000-00 IF, and 9534-0000-014FO1 MDA's do not meet the CRDL. Small aliquots were taken due to high radiation screens. Except as noted, the LCS, batch blank, sample and sample duplicate results are within acceptance limits.Carbon-14 by method RTCH-RC-5022:
The aliquot taken for the samples was not larger enough in order for the MDA to meet the CRDL. The client was notified via e-mail about the error and the laboratory will reanalyze these samples at the client's request in order to meet the CRDL. Except as noted, the LCS, batch blank, sample and sample duplicate.
results are within acceptance limits.4 Connecticut Yankee Atomic Power Company February 16. 2004 Page 3 Iron-55 bv method RICH-RC-5074:
Samples 9536-OO0 011F and 9537-0000-014F01 have tracer yields above 1 15% due to matrix effect (indigenous iron in the soil). Except as noted, the LCS, batch blank, sample and sample dupliCLLte results are within acceptance limits.Nickel-63 by method RICH-RC-5069:
The LCS, batch blank, sample and sample duplicate results are within acceptance limits.Plutonium-241 by method RICH-RC-5010:
The LCS, batch blank, samples and sample duplicate results are within acceptance limits.Technetium-99 by method RICH-RC-5078:
The LCS. batch blank, samples, sample duplicate and are within acceptance limits.Tritium by method RICH-RC-50371-The LCS, batch blank, sample and sample duplicate results are within acceptance limits.I certify that this Certificate of Analysis is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager, or a designee as verified by the following signature.
Reviewed and approved: Theresa H. Kallsen Project Management Assistant 5 Drinking Water Method Cross References
_ _DRINKING WATER ASTM METHOD CROSS REFERENCES Referenced Method Isotope(s)
STIL Richland's SOP number EPA 901.1 Cs-134, 1-131 RICH-RC-5017 EPA 900.0 Alpha & Beta RICHI-RC-5014 EPA 903.1 Ra-226 RICH-RC-5005 EPA 904.0 Ra-228 RICH-RC-5005 EPA 905.0 Sr19/90 RICH-RC-5006 ASTM 02460 Total Radium RICH-RC-5027 Standard Method 7500-U-C & ASTM D5174 Uranium RICH-RC-5058 EPA 906.0 Tritium RICH-RC-5007 NOTE: rThe Gross Alpha LCS is prepared with Am-241 (unless otherwise specified in the case narrative)
The Gross Beta LCS is prepared with Sr/Y-90 (unless otherwise specified in the case narrative)
Uncertainty Estimation STL Richland has adopted the internationally accepted approach to estimating uncertainties described in "NIST Technical Note 1297, 1994 Edition".
The approach.
'Law of Propagation of Errors", involves the identification of all variables in an analytical method which are used to derive a result. These variables are related to the analytical result (R) by some functional relationship, R = constants
- f(x.yz...).
The components (xy.z) are evaluated to determine their contribution to the overall method uncertainty.
The individual component uncertainties (tu) are then combined using a statistical model that provides the most probable overall uncertainty value. All component uncertainties are categorized as type A. evaluated by statistical methods, or type B. evaluated by other means. Uncertainties not included in the components, such as sample homogeneity, are combined with the component uncertainty as the square root of the sum-of-the-squares of the individual uncertainties.
The uncertainty associated with the derived result is the combined uncertainty (uJ multiplied by the coverage factor (1,2, or 3).When three or more sample replicates are used to derive the analytical result, the type A uncertainty is the standard deviation of the mean value (S/vn), where S is the standard deviation of the derived results. The type B uncertainties are all other random or non-random components that are not included in the standard deviation.
The derivation of the general 'Law of Propagation of Errors' equations and specific example are available on request.hland 6 Action Lev Batch Bias COC No Count Error (#s)Report Definitions An agreed upon activity level Uised to trigger some action when the final result is greater than or equal to the Action Level. Often the Action Level is related to the Decision Limit.The QC preparation batch number that relates laboratory samples to QC samples that were prepared and analyzed together.Defined by the equation (Result/Expected)-l as defined by ANSI N13.30.Chain of Custody Number assigned by the Client or STL Richland.Poisson counting statistics of the gross sample count and background.
The uncertainty is absolute and in the same units as the result. For Liquid Scintillation Counting (LSC) the batch blank count is the background.
Total Uncert (#s)a u Combined Uncertainy.
(#s), Coverage Factor CRDL (RL)All known uncertainties associated with the preparation and analysis of the sample are propagated to give a measure of the uncertainty associated with the result, it, [lte combined uncerrainty.
The uncertainty is absolute and in the same units as the resulL The coverage factor defines the width of the confidence interval, 1. 2 or 3 standard deviations.
Contractual Required Detection Limit as defined in the Client's Statement Of Work or STL Richland udefault" nominal detection limit. Often referred to the reporting level (RL)Decision LUvel based on instrument background or blank, adjusted by the Efficiency, Chemical Yield, and Volumne associated with the sample. The Type I error probability is approximately 5%. Lc=(1.645' Sqrt(21(BkgrndCnt/BkgmdCntMin)ISCntMin))
0 (ConvFctl(Eff'Yld*Abn*Vol)
I IngrFe). For LSC methods the batch blank is used as a measure of the background variability.
Lc cannot be calculated when the background count is zero.Lot-Sample No-MDCIMDA Primary Detector Ratio U-234/U-238
- RstlMDC RstaotUcert The number assigned by the LIMS software to track samples received on the same day for a given client The sample number is a sequential number assigned to each sample in the LoL Detection Level based on instrument background or blank. adjusted by the Efficiency.
Chemnical Yield, and Volumre with a Type [and 11 error probability of approximately'5%.
MDC = (4.65 *Sqrt((BkgrndCnt/BkgmdCatMin)ISCntMin)
+ 2.71/SCntMin)
- (ConvFct/(Eff
- Yld
- Abn
- Vol)
- lngrFct).
For LSC methods the batch blank is used as a measure of the background variability.
The instrument identifier associated with the analysis of the sample aliquot The U-234 result divided by the U-238 resulL The U-234/U-238 ratio for natural uranium in NISTSRM 4321C is 1.038.Ratio of the Result to the MDC. A value greater than I may indicate activity above background at a high level of confidence.
Cautdon should be used when applying this factor and it should be used in concert with the qualifiers associated with the resulL Ratio of the Result to the Total Uncertainty.
If the uncertainty has a coverage factor of2 a value greater than I may indicate activity above background at approximately the 95% level of confidence assuming a two-sided confidence interval.
Caution should be used when applying this factor and it should be used in concert with the qualifiers associated with the result._i Report DB No Sample Identifier used by the report system. The number is based upon the first five digits of the Work Order Number.The equation Replicate Error Ratio = (S-D)/[sqrt(TPUs 2+ TPUd')] as defined by ICPT BOA where S is the original sample result. D is the result of the duplicate.
TPUs is the total uncertainty of the original sample and TPUd is the total uncertainty of the duplicate sample., SDG Sum Rpt Alpha i Spec Rst(s) --Work Order I Yield II hWand 21W Y3.;I Sample Delivery Group Number assigned by the Client or assigned by STL Richland upon sample receipt The sum of the reported alpha spec results for tests derived from the same sample excluding duplicate result where the results are in the same units. -The LIMS software assign test specific identifier.
The recovery of the tracer added to the sample such as Pu-242 used to trace a Pu-239/40 method.7 Sample Results Summary Date: 16-Feb-04 STL Richland STLR Ordered by Method, Batch No., Client Sample ID.Report No. :24916 3DG No: 24921 Client Id MDC or Work Order Parnmeter Result .- Uncertainty ( 2s) Quat Units Yield MDA CRDL RER2 341 FBXZ 36-0000-01 2F (F5XD7)_F7PRF1AH FE-55 1.18E+01 4- 5.68E+00 U pCVg 116% 1.92E+01 1.10DE03 536-0000-01 3F (F5XD8)F7PTDIAH FE-55 6.26E+00 -5.38E+00 U pClg 75% 1.45E+01 1.10E+03 8-37-0000-001 F (FSXFG)F7PTH1AH FE-55 7.19E+00 + 4.98E+00 U pCVg 98% 1.48E+01 1.102+03 37-00001 4F01 (F5XHIM)--F7PTJ1AH FE-55 1.45E+01 4 6.06E+00 U pCi/g 118% 1.94E+01 1.10E+03 37-0000-0114F01 (F5XHM) DUP F7PTJ1AM FE-55 4.99E+00 4 5.30E+00 U pCvg 90% 1.76E+01 1.10E+03 347 C.MUO ,36-000001 2F (F5XD7)P7PRF1AD SR-90 6.37E-02 -3.49E-02 pC~ g 69% 6.06E-02 6.00E-02 a36-0000-013F (F5XD8)F7PTD1AD SR-90 1.36E-01 -7.82E-02 U pCVg 62% 1.38E-01 6.002E02 37-0000-001F (F5XFG)-F7PTH1AD SR-90 7.02E-02 -4.10E-02 U pCvg 63% 7.16E-02 6.002-02 ,17-0000-0114F01 (FSXHM)-7PTJ1AD SR-90 2.37E-02 -3.09E-02 U pCVg 67% 6.43E-02 6.002-02'37-000-014714F1 (F5XHM) DUP F7PTJ1AN SR-90 2.73E-02 -3.38E-02 U pCvg 68% 7.03E-02 6.00E-02 4 RICHRC5080 536-0000-012F (F5XD7)P7PRF1AK AM-241 1.57E-01 1.23E-01 J pCVg 800% 6.08E-02 1.03E+00 CM-242 O.OOE+00 +- 7.42E-02 U pC/g 80% 8.21E-02 CM-243t244 226E-02 +- 4.54E-02 U pC/g 80% 6.12E-02 1.16E+00--6-0000O01 2F (F5XD7) DUP.7PRF1AL AM-241 4.36E-02 +- 623E-02 U pCI/g 77% 5.90E-02 1.03E+00 CM-242 O.OOE+00 -7.21E-02 U pCvg 77% 7.98E-02 CM-243/244 0.002+00 -5.38E-02 U pCvg 77% 5.95E-02 1.16E+00 L'5-0000-01 3F (F5XD8)F7PTD1AK AM-241 -8.44E-03
+- 1.71E-02 U pCvg 70% 2.02E-01 1.03Ei CO CM-242 O.OOE+00 +- 1.40E-01 U pCVg 70% 1.54E-01 CM-243/244 O.OOE+00 +- 1.04E-01 U pCvg 70% 1.15E-01 1.16E+00 337-000000l F (F5XFG)1 7PTH1AK AM-241 4.11E-02 -5.87E-02 U pCVg 70% 5.56E-02 1.03E+00 CM-242 0.00E+00 -7.00E-02 U pCVg 70% 7.74E-02 CM-243/244
_. O.OOE+00 -5.07E-02 U pClg 70% 5.61E-02 1.16E+00 7-0000-014F01 (F5XHM)1lchland RER2 Replicate Error Ralo = (S-DY[sqrt(sq(TPUs)+sq(TPUd))]
ss defined by ICPT BOA.IchSaSum J Qual -No UIc qualificr has been assigned and the result i below the Reporting Limit, RL (CRDL) or Report Value Ls Estmnate'!.
l4.05 A97 U Qual -Analyzed ror, but the result Is less than the Mdc Idp`otaI Uncert or gamna scan software did not Identify the nuclde.8 Sample Results Summary STL Richland STLR Ordered by Method, Batch No., Client Sample ID.Date: 1 6-Feb-04 Report No.: 24916 SOG No: 24921: Client Id rIn Work Order Parameter Result +- Uncertalnty ( 2s)MDC or Yield MDA lua? Units CRDL RER2 134 RICHRCS08O 37-0000-014F01 (F5XHM)-F7PTJ1AK AM-241 CM-242 CM-2431244 336 RICHRC5010 0000-012F (F5XD7)F7PRFlAE PU-238 PU239/40 36-0000-013F (F5XD8)F7PTD1AE PU.238 PU239/40 36-0000-013F (F5XD8) DUP_F7PTO1AL PU-238 PU239/40 37-0000-001 F (F5XFG)L F7PTHlAE PU-238 PU239/40 37-0000-014F01 (F5XHM)L=7PTJIAE PU .238 PU239140 17 RICHRCSo10 0000-012F (F5XD7)F7PRFIAF PU-241 36-0000-013F (FSX08)-.77PTD1AF PU-241 536-0000-013F (F5XD8) DUP-7PTDIAM PU-241 x37-0000-001F (F5XFG)F7PTHIAF PU-241 i 37-0000-014F01 (F5XHM)-r7PTJlAF PU-241.40 RICHRCS069 I 16-0000-012F (FSXD7)L 1 7PRFIAG NI-63 536-0000-013F (F5X08)'7PTD1AG NI-63 337-0000-001 F (F5XFG)F7PTH1AG NI-63l 17-0000-014F01 (F5XHM)O.OOE+00 O.OOE+00 O.OOE+00+- 4.69E-02+- 6.55E-02.- 4.73E-02+- 6.11E-02+- 5.01 E-02.- 1.42E-01+- 1.42E-01 U pCfg U pCVg U pClg U pCUg U pCUg U pCvg U pCvg 69°'o 69%69%0 5.19E-02 7.25E-02 5.23E-02 1.03E+00 1.16E+00 O.OOE+00 2.49E-02 O.OOE+00 0.00o2+00 60% 6.76E-02 1.18E+00 60% 6.75E-02 1.07E+00 52% 1.58E-01 1.18E+00 52% 1.57E-01 1.07E+00 0.00E+00 .+- 1.39E-01 0.00E+00 +- 1.39E201 1.92E-02 2.40E-02+- 4.92E-02 1- 4.33E 02 U pCVg U pC/g U pCVg U pClg U pCLg U pCi/g 50% 1.54E-01 1.18E+00 50% 1.54E-01 1.07E+00 51% 1.152-01 1.18E+00 51% 6.51 E-02 1.07E200 O.OOE+00 +- 1.30E-01-1.06E-02
+- 2.13E-02 21% 1.43E-01 21% 2.53E-01 1.18E+00 1.07E+00 3.77E-01 +- 3.03E+00 2.83E+00 +- 7.15E+00 9.14E+00 +- 7.78E+00 3.14E+00 +- 3.77E+00 1.33E+01 +- 9.45E+00-7.08E-02
+- 4.00O+00 3.93E-01 +- 4.51E+00 U pCLg 60% 5.96E+00 3.48E+01 U pCvg 52% 1.38E+01 3ABE+01 U pCvg 50% 1.40E+01 3.48E+01 U pC/g 51% 7.09E+00 3.48E+01 U pCI/g 21% 1.68E+01 3.48E+01 U pCVg 91% 5.68E+00 2.89E+01 U pCi/g 83% 7.01E+00 2.89E+01 U pC/g 86% 7.62E+00 2.89E+01--- 2.79E+00.- 4.63E+00 llchland RER2 -Replicat Error Rldo = (S-DY4sqrt(sq(TPUs)+sq(TPUd))l as defined by ICPI BOA.RchSaSurn U Qual Analyzed ror, but the resilt is less thnn the MddMdarTotal Uncert or ganmn scan software did not identity the rcldd-.1 V4.05 A97 9 Sample Results Summary STL Richland STLR Ordered by Method, Batch No., Client Sample ID.Date: 16-Feb-04 SOG No: 24921 Report No.: 24916 I Client Id n Work Order Parameter MDC or MDA CRDL RER2 Result +- Uncertainty( 2s)Qual Units Yield 340 RICHRCS069 37-0000-014F01 (F5XHM)-F7PTJ1AG NI-63 537-0000-014F01 (F5XHM) DUP F7PTJ1AL NI-63 343 RICHiRCS078 z36-0000-01 2F (F5XD7)F7PRFIAC TC-99 536-0000.012F (F5XD7) DUP F7PRFIAM TC-99 36-0000-013F (F5XD8)F7PTD1AC TC-99* 37-0000-001F (FSXFG)F7PTHlAC TC-99 537-0000-014F01 (F6XHM)F7PTJIAC TC.99 iS RICHRCS037 536-0000-01 2f (FSXD7)r7PRFIAJ H-3 36-0000-013F (F5X08)F7PTD1AJ H-3-37-0000-001F (F5XFG)--7PTH1AJ H-3 537-0000-001F (F5XFG) DUP-'7PTH1AM H-3.7-0000-014FOt (F5XHM)F7PTJ1AJ H-3 6 RICHRCSO22 6-0000-012F (F5XD7)F7PRF2AA C-14 6-0000-013F (F5XD8)_7PTD2AA C-14 537-0000-001 F (F5XFG)-7PTH2AA C-14 7-0000-001F (FSXFG) DUP F7PTH2AL C-14 7-0000-014F01 (F5XHM)-PTJ2M C-14 b. of Results: 60 2.62E+00 3.86E+00 2.40E-01 1.44E-01 1.67E-01 1.89E-01 1.1 BE-01 2.43E-02 5.57E-02 2.12E-02 1.87E-02 6.59E-02 3.96E-02 4.66E-02 1.79E-01 1.47E-01-3.30E-02 4.13E+00+ 3.96E+00+ 1.55E-01 4 1.50E-01-1.51E-01 4 1.52E-01-1.48E-01+ 2.57E-02-2.50E-02 S 1.55E-02 4 1.57E-02 4- 1.68E-02+- 1.84E-01+- 1.83E-01 4 1.88E-01+ 1.87E-01 4 1.82E-01 U pC11g U pC/g U pCvg U pCifg U pCL'g U pCvg U pC/g U pCVg U pCig U pCvg U pCvg J pCVg U pC/g U pClg U pC/g U pC1/g U pCvg 92%99%100%100%1000/a 1000%1 OM%1 00M/100%100%y 100%100%100%100%Y 100%100%100%5.63E+00 5.27E+00 2.49E-01 2.48E-01 2.48E-01 2.49E-01 2.47E-01 7.24E-02 6.24E-02 3.61 E-02 3.86E-02 2.97E-02 3.38E-01 3.37E-01 3.39E-01 3.39E-01 3.39E-01 2.89E+01 2.89E+-01 5.04E-01 5.04E-01 5.04E-01 5.04E-01 5.04E-01 1.65E+01 1.65E+01 1.65E+01 1.65E+01 1.65E+01 2.26E-01 2.26E-01 2.26E-01 2.26E-01 2.26E-01 31chland RER2 Replicate Error Ratio = (S-Dy)sqrt(sq(rPU3)+sq(TPUd))l as defined by ICPT BOA.lchSaSum J Qual -Nio Li< qualifier has been omignLd and the result is below the Reporting Llmil, RL (CRDL) or Report Value Is Esttrated.
'4.05 A97 U QuaJ .Analyzed ror, but the result is less than the Mdc/Mdaromal Uncert or ganm scan software did not identify the nuclide.t0 QC Results Surmunary STL Richland STLR Ordered by Method, Batch No, 0C Type,.Date: 16-Feb-04 SDG No.: 24921 Report No.: 24916 Work Order Parameter Result .- Uncertainty ( 2s)Qual Units Yield Recoverv Bias MOCIMnA-..--!I:341 BLANK CC F7VCXIAA r'2341 LCS-7VCXlAC F D'2347 BLANK QC-7VC71 AA T2347 LCS F7VC7AC c'csa80-r2334 BLANK QC'E-55 7.88E+00 +- 5.48E+00 5.98E+01 i- 1.29E+01 3R-c90 3R-90 6.59E-03 +- 1.71E402 5.01 E-01 .- 8.57E-02 F7VCG1AA AM-241 CM-242-CM-2431244 12334 LCS-7VCG1AC AM-241'HCS010 12336 BLANK QC-7VCM1AA PU-238_- PU239140 0.OOE+00 .t- 1.76E.02 0.00E+00O+
2.37E.02 0.OOE+00 +- 1.77E.02 4.27E+t00
.- 8.1 6E-01 O.OOE+00 4- 2.1 6E.02-1 .76E-03 +- 3.53 E-03 5.35E-01 +- 1.46E-01 1.46E+00 .i- 1.25Et00 1 .89E+01 ..- 2.30E+00 12336 LCS*7VCM1AC PU239_-CSD010 12337 BLANK QC 7VCNlAM PU-241!337 LCS F7VCN1AC PU-241 1C5069!340 BLANK QC lF7VCTIAA Nl-63 12340 LCS*7VCTIAC NI-63 FRCS078 12343 MATRIX SPIKE-7PTDlAN TC-99.-343 BLANK QC F7VC11AA TC-99.343 LCS_7VC11AC TC-99 iRCSa37! !345 BLANK QC L.7VC31AA H-3 12345 LCS 140 U pCvg J pC/g U pCvg pCVg U pCVg U pCvg U pCvg pCi/g U pCL/g U pCvg J pcu/g U pcig J pCig U pC1/g pC~g pCilg J pCilg J pCVg 85%85%76%78%66%66%66%88%47%47%54%47%54%90%89%100%100%100%1.48E+01 111% 0.1 1.49E+01 3.74E-02 109%,o 0.1 3.64E-02 1.95E-02 2.63E-02 1.96E-02 94% -0.1 1.38E-02 2.38E-02 4.21 E-02 1.65E-02 116% 0.2 I I 2.44E+00 +- 4.32E+00 4.80E+02 +- 7.58Es.01 2.51E+01 4- 1.65Et.00 2.56E-01 +- 1.56E-01 1.32E+01 +- 9.21 E-01 6.13E.02 +-.1.23E-01 2.30E+00 83% -0.2 1.97E+-00 6.1 8E+00 95% -0.1 6.61 E*0O0 92% -0.1 2.49E-01 2.48E-01 97% 0.0 2.49E-01 U pCVg 100%Y 2.65E-01 ,'1chland Bius .(ResultExpected)-.
as defined by ANSI N13.3Q.I.RchacSum J Qual -No Ule qualifier bas been assigned and the result Is below the Reporting Limit, RL (CRDL) or Report Value Is Estimated.
cV4.0S A97 U Qual -Analyzed for, but the result is less than the Mdc/ Nda4rotal Uncert or gaamm scan software did not Identify the nuelide.11 QC Results Summary STL Richland STLR Ordered by Method, Batch No, QC Type..Date: 16-Feb-04 Report No.: 24916 SDG No.: 24921 Work Order Parameter Result -Uncertainty ( 2s) Oual Units Yield Recovery Bias MDC[MDA 7VC31AC H-3'7CSO22 2536 BLANK CC 7VCP2AA C-14 t.536 LCS F7VCP2AC C-14.of Results: 22 2.72E.00 +- 2.44E-01 2.73E-02 +- 7.47E-02 7.34E400 +- 2.95E-01 i pCVg 100% 99% 0.0 2.63E-01 U pCL/g 100%1.37E-01 pCIg 100% 101% 0.0 1.37E-01.*hland.RchOcSurn'V4.05 A97 B8s -(ResutUExpened)-4 3s defined by ANSI N13J30.J Qual -No UlV qualiflier has been asigned and the result Is below the Reporting Limit. RL (CRDL) or Report Value u Estimated.
Ul Qual -Analyzed for, but the result Is less than the il'ld/MdlaTatal Uncert or g2mma scan software did not identify the nuclide.12 F i: I I (. I 4 1. , I r I .-SAMPLE RESULTS Lab Name: STL Richland Lot-Sample No.: J4A080282-1 Client Sample ID: 9536-0000-012F (F5XD7)SDG: Report No.: COC No.: 24921 24916 2003-00239 Collection Date: 11/21/2003 10:12:00AM Received Data: 1/8/2004 12:00:00 PM Matrix: SOIL Ordered by Client Sample ID. Batch 1 Result Count Total MDCIMDA. Rpt Unit, Yield RsUJMDC, Analysis.
Total Sa Aliquot Prim Parameter Qual Error ( 2 *) Uncerl( 2 a) Action Lev Le CRDL(RL) Rsl/TolUcert Prep Data Size Size Delec Batch: 4012334 RICHRC5080 Work Order: F7PRF1AK Report DB ID: 9F7PRF10 AM-241 1.57E-01 J 1.19E-01 1.23E-O1 6.08E-02 pCI/g 80% (2.6) 1/31/04 04:30 a 0.6031 ALP 1.03E+00 (2.5) G CM-242 O.OOE+00 U O.OOE+0O 7.42E-02 8.21E-02 pCI/g 80% 0. 1/31/04 04:30 a 0.6031 ALP 0. G CM-243/244 2.26E-02 U 4.52E-02 4.54E-02 6.12E-02 pClg 80% 0.37 1/31/04 04:30 a 0.6031 ALP 1.16E+OO 0.99 G 869h: 4012336 RIC11RC5010 Work Order: F7PRF1AE Report DB ID: 9F7PRF10 PU-23B O.OOE+00 U O.OOE+0O 6.1 1E.02 6.76E-02 pCI/g 60% 0. 2/2/04 03:27 p 0.6019 ALP 1.18E+00 0. G PU239/40 2.49E-02 U 4.98E-02 5.01E-02 6.75E-02 pCI/g 60% 0.37 2/2/04 03:27 p 0.6019 ALP 1.07E+00 0.99 G Batch: 4012337 RICHRC5010 Work Order. F7PRF1AF Report DB ID: 9F7PRF10 PU-241 I 3.77E-01 U 2.43E+00 3.03E+00 5.96E400 pCIg 60% 0.06 216/04 06:27 p 0.6019 LS(2.81 E+00 3.48E401 0.25 G Batch: 4012340 RICHRC5069 Work Order: F7PRFIAG Report DR ID: 9F7PRF10 NIl63 -7.08E-02 U 2.36EfO0 4.00EtO0 5.68E+00 pCVg 91% -0.01 1/29/04 08:01 p 0.2518 LS(2.75E+00 2.89E+01 -0.04 G Batch: 4012341 FBXZ Work Order: F7PRF1AH Report DB ID: 9F7PhF10 FE-55 1.18E+O1 U 5.68E+00 1.92E+01 pCIg 116% 0.62 1/30/04 01:43 p 0.251B LSC 9.12E+00 1.1OEt03 (4.2) G STL Richiand rpISTIRchSample V4.05 A97 UDCIMDALc
-Detection.
Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.J Oual -No Uj< qualifier has been assigned and the result Is below Ihe Reporting Limit, RL (CRDL) or Report Value Is Estimated.
U Oual -Analyzed for, but the result Is less than the Mdc/MdalTutal Uncert or gamma scan software dil not Identify the nuclide.
-( ( ( ( ( Jll,, ((t( ( I IIate! lb-Feb!'4 SAMPLE RESULTS Lab Name: Lot-Sample No.: STL Richland J4A080282-1 SDG: Report No.: 24921 24916 Collection Di Recelved Dal Matrix: ta(: 11/21/2003 10:12:00 AM t: 1/8/2004 12:00:00 PM SOIL frdered by Client Sample ID. Batch, Client Sample ID: 9536-0000-012F (F5XD7)COC No.: 2003-00239 Result Count Total MDCIMDA, Rpt Unit, Yield RstIMDC, Analysts, Total Sa Aliquot Prin Parameter Qual Error ( 2 *) Uncert( 2 ) Action Lav Le CRDL(RL) R&UTolUcert Prep Date Size Size Dole Batch: 4012343 RICHRC5078 Work Order: F7PRF1AC Report PB ID: 0F7PRF10 TC-99 2.40E-01 U 1.102-01 1.55E101 2.49E-01 pCI~g 100% 0.96 2/6104 11:07 a 5.0 L 1.19E-01 5.04E-01 (3.1) G Batch: 4012345 RICHRC5037 Work Order. F7PRFtAJ Report DS ID: 9F7PRF10 H-3 2.43E-02 U 2.40E-02 2.57E.02 7.24E-02 pCI/g 100% 0.34 1/20/04 01:11 .. 100.1 LS 3.36E.02 1.65E+01 (1.9) G B.ich: 4012347 CMUD Work Order: F7PRF1AD Report DB ID: 9F7PRF10 SR-90 6.37E-02 3.31E-02 3.49E-02 6.06E-02 pCVg 69% (1.1) 218/04 06:48 a 6.03 GP1 2.68E.02 6.002-02 (3.7) G Batch: 4022538 RICHRC5022 Work Order: F7PRF2AA Report DD ID: 9F7PRF20 C-14 3.96E.02 U 1.432-01 1.84E-01 3.36E-01 pCI/g 100% 0.12 1/26/04 01:17 p 2.025 LS 1.662-01 2.26E-01 0.43 G No. of Result.: 12 Comments: ' !STL Rlchland MDCIMDA.Lc
-Detoctlon, DecIsion Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.rptSTLRchSimple J Oual -No Ul qualifier has been assigned and the result Is below the Reporting LImit, RL (CRDL) or Report Value Is Estimated.
V4.05 A97 U Oual -Analyzed for, but the result Is less than the MdclMdalotal Uncert or gamma scan software did not Identify the nucilde.
( ---( --- [ [ -( -.. -( I I I atoe! 10-Fobtu'.
SAMPLE RESULTS Lab Name: STL Richland Lot-Sample No.: J4A080282-2 Client Sample ID: 9536-0000-013F (F5XD8)SDG: Report No.: 24921 24916 COC No.: 2003-00239
.Parameter Batch: 4012334 AM-241 CM-242 CM-2431244 B&9h: 4012336 PU-238 PU239/40 Result RICHRC50BO
-8.44E -03 O.OOE+00 0.006+00 RICHRC5010 O.OOE-00 O.OOE+00 Qual U U U Counl Error ( 2 )1.69E-02 0.00t00 0.OOE-rOO Total Uncer( 2 s)Work Order: 1.71 E-02 1.40E-01 1.04E-01 Work Order: 1.42E-01 1.42E-01 MDC MDA Action Lea F7PTD1AK 2.02E-01 1.54E-01 1.15E-01 F7PTD1AE 1.55E-01 1.57E-01 Rpt Unit, Yield RsVMOC, Ltc CRDL(RL) Rst/TotlUcert Report DB ID: 9F7PTDI0 pCI/g 70% -0.04 4.39E-02 1.03EtOO -0.99 pClg 70°h 0.0.pCi/g 70% 0.1.16E+00 0.Report DB ID: 9F7PTD10 pCI/g 52% 0.1.18E+00 0.pCUg 52% 0.1.07E+00 0.Collection Date: 11/21/2003 9:40:00 AM Received Date: 1/8/2004 12:00:00 PM Matrix: SOIL Ordered by Client Sample ID, Batch N Analysis, Total Sa Aliquot Primi Prep Date Size Size Detec 1/31/04 04:32 a 0.3016 ALP G 1/31/04 04:32 a 0.3016 ALP, G 1/31/04 04:32 a 0.3018 ALP1 2/2104 03:27 p 0.3014 ALPI G 2/2/04 03:27 p 0.3014 ALP1 G..U U O.OOE+00 O.OOE+00 Batch: 4012337 RICHRCSOI5 Work Order: F7PTD1AF Report DB ID: 9F7PTDIO PU-241 2.83+500 U 5.72E+00 7.15E+00 1.38E+01 pCVg 52% 0.21 216/04 06:27 p 0.3014 LSG 6.50E+00 3.48E+01 0.79 G Batch: 4012340 RICHRC5069 Work Order: F7PTD1AG Report DO ID: 9F7PTD10 Ni-63 3.93E-01 U 2.76E+00 4.51E+00 7.01E+00 pCilg 83% 0.06 1129/04 09:43 p 0.2519 LSC I 3.39E+00 2.89E+01 0.17 G Batch: 4012341 FBXZ Work Order: F7PTDIAH Report DB ID: 9F7PTD10 FE-55 6.262+00 U 5.38E+00 1.45E+01 pCVg 75% 0.43 1/30/04 01:43 p 0.2519 LSC 6.89E+00 1.10E+03 (2.3) G STI 01R l-ln n I n -tsn rw__r.____-
__ ..rptSTLRchSample V4.05 A97 MU%.IrAD.Lc
-uetecuon, Decision Level based on Inatrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.J Ouas -No U.1c qualifier has beon assigned and Ihe result Is below the Reporting Limit, RL (CRDL) or Report Value Is Estimated.
U Oual -Analyzed for, but the result Is less than the Mdc/MdalTotal Unceur or gamma scan sotiware did not Identity the nuclide.
(i r( (-- 7 r r: .Il. r -..11 (SAMPLE RESULTS ( ( Vi V ( V OtO 7 ' -- -(Dt,16-Feb-04 Lab Name: Lot-Sample No.: Client Sample ID: STL Richland J4AOB0282-2 9536-0000-013F (F5XDB)SDG: Report No.;24921 24916 Collection Date: Received Date: Matrix: 11/21/2003 9:40:00 AM 1/1/2004 12:00:00 PM SOIL CoC No.: 2003-00239 Ordered by Client Sample ID, Batch I\Result Count Total MDCIMDA, RptUnit, Yield RsUMDC, Analysis, Total Sa Aliquot Prim Parameter Cual Error ( 2 ') Uncory1 2 a) Action Lev Lc CRDL(RL) RstiolUcert Prep Date Size Size Dotec Batch: 4012343 RICHRC5078 Work Order: F7PTD1AC Roport DD ID: gF7PTD10 TC-99 1.67E-01 U 1.07E-01 1.51E-01 2.48E-01 pCI/g 100% 067 216104 01:12 p 5.0 LSI 1.t9E-01 5.04E-01 (2.2) G Batch: 4012345 RICHRCS037 Work Order: F7PTDIAJ Report DU ID: 9F7PTD10 H-3 5.57E-02 U 2.35E-02 2.50E.02 6.24E-02 pCVg 100% 0.89 1t20/04 01:54 a 100.2 LS(2.90E-02 1.65E+01 (4.5) G BUh: 4012347 CMUD Work Order: F7PTD1AD Report DB ID: 9F7PTD10 cn SR-90 1.36E-01 U 7.45E-02 7.82E102 1.38E-01 pCVU 62% 0.99 2/8/04 06:48 a 3.01 GPC 6.12E.02 6.OOE-02 (3.5) G Batch: 4022538 RICHRC5022 Work Order: F7PTD2AA Report DO ID: 9F7PTD20 C.14 4.66E-02 U 1.43E-01 1.83E-01 3.37E-ut pCI/g 100% 0.14 1/26104 01:17 p 2.031 LSC 1.66E-01 2.26E.01 0.51 G No. of Results: 12 Comments: qT1 ~~~~~ !lhor m m jn rptSTLflchSomple V4.05 A97*-I5.% Li0 uLacILUI, UeGislon Level basea on insitrument background or blank, adiusted by the sample Efficiency, Yield, and Volume.J Qual -No Ulc qualifier has been assigned and the result Is below the Reporting Limit, RL (CROL) or Report Value Is EstImated.
U Qual -Analyzed for, but the result Ia lesa than the Mdc1MdalTotaI Uncert or gamma scan software did not Identify the nucilde.
Lab Name: STL Rlchland Lot-Sample No.: J4A080282-3 Client Sample ID: 9537-0000-001F (F5XFG)(( ( .(SAMPLE RESULI SDG: 24921 Report No.: 24916 COC No.: 2003-00-(Date 16Feb*04 rs CollectIon Date: 11/14/2003 10:4 5:00 AM Received Date: 1/8/2004 12:00;00 PM 241 Matrix: SOIL Cndered by Client Sampla ID, Balch I`Yield RsttMDC, Analysis, Total Sa Aliquot Prim IDL(RL) RstrotUcert Prep Date Size Size Dete(Tota -DIM Parameter Batch: 4012334 AM.241 CM-242 CM-243/244 Result RICHRC508O 4.1 1E.02 0.OOE+00 0.OOE+O0-Count Qual Error ( 2')U 5.81E-02 U 0.00E+00 U 0.OOE+00 Tolal Uncerl( 2 ')Work Order: 5.87E-02 7.OOE.02 5.07E.02 MDCIMDA.Action Lev F7PTH1AK 5.56E-02 7.74E-02 5.61 E-02 Report DB ID: 9F7PT1H10 pC/g 70% 0.74 1.03E+00 (1.4)pCI/0 70% 0.0.pCl/g 70% 0.1.16E+00 0.Report DB ID; 9F7PTH10 pClg 51% 0.17 2.51E-02 1.18E40 0.78 pCI/g 51% 0.37 1.07EtOO 0.99 Rpt Unit, Lc CR 1/31/04 04:32 a 1131/04 04:32 a 1/31/04 04:32 a 0.6013 ALP G 0.6013 ALP G 0.6013 ALP G 0.6009 ALP G 0.6009 ALP G_ .Batih: 4012336 PU-238 PU239140 RICHRC5010 1.92E.02 2.40E.02 U LI 4.91 E-02 4.8OE02 Work Order: 4.92E-02 4.83E-02 F7PTH-IAE 1.15E-01 6.511E-02 212104 06:42 p 212104 06:42 p Batch: 4012337 RICHRC5010 WorkOrder:
F7PTH1AF Report DS ID: 9F7PTH10 PU-241 3.14E+00 U 3.02E+00 3.77E+00 7,09E+00 pCI/g 51% 0.44 2/6/04 06:27 p 0.6009 LSC 3.34E+00 3.48E+01 (1.7) G Batch: 4012340 RICHRC5069 Work Order: F7PTHIAG Report DO ID: GF7PTH10 Ni.63 2.79E+00 U 2.90EtO0 4.63E+00 7.62E+00 pCI/g 86% 0.37 1/29/04 11:26 p 0.2508 LSC 3.69EtO0 2.89E+01 (1.2) G Batch: 4012341 FBXZ Work Order: F7PTH1AH Report DOB ID: 9F7PTHl0 FE-55 7.19E+00 U 4.98E+00 1.48E+01 pC/g 98% 0.48 1/30/04 01:43 p 0.2508 LSC 7.06Et00 1.lOE+03 (2.9) G STL Richland rptSTLRchSample V4.05 A37 MDCIMDALc
-Detection, DecIsion Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.J Qual -No UJc qualifier has been asslgned and the result Is below the Reporting LImit, RL (CRDL) or Report Value Is Estimated.
U qual -Analyzed for, but the result Is less than the Mdc]MdalT'tal Uncert or gamma scan software did not Identify the nucllde.
( _( .1 C( (S (AME RS ( UL T S .I SAMPLE RESULTS I -.(** -( -.. -f-( Dater: '16*Feb*04 Lab Name: STL Richland Lot-Sample No.: J4A080282-3 Client Sample ID: 9537-0000-001F (F5XFG)SDG: Report No.;24921 24916 Collection Dat.: Received Date: Matrix: 11/14/2003 10:45:00 AM 1/8/2004 12:00:00 PM SOIL COC No.: 2003-00241 Ordered by Client Samplo ID, Batch I Result Count Total MCIlMDA, Rpt Unit, Yield Rsl/MDC, Analysis, Total So Aliquot Prln Parameter Qual Error ( 2 a) Uncert( 2 a) Action Lev Le CRDL(RL) RstJTotUcert Prep Dato Size Size Dote Balch: 4012343 RICHRCS078 Work Orden F7PTH1AC Report 0l ID: 9F7PTH10 TC-99 1.89E-01 U 1.OSE-O1 1.52E-O1 2.49E-01 pCL'g 100% 0.76 2/6/04 03:17 p 5.0 LS 1.19E-01 5.04E-01 (2.5) G Batch: 4012345 RICHRC5037 Work Order: F7PTH1AJ Report DB ID. 9F7PTH10 H-3 2.12E-02 U 1.43E-02 1.55E.02 3.61E*02 pCI/g 100% 0.59 1/20/04 02:36 a 100.1 LS 1.68E-02 1.65Ei01 (2.7, G Batch: 4012347 CMUD Work Order: F7PTH1AD Report DB ID: OF7PTH10 X SR-90 7.02E-02 U 4.03E-02 4.10E-02 7.16E-02 pCI/0 63% o.98 218/04 06:48 a 6.01 GP(3.20E-02 6.00E-02 (3.4) G Batch: 4022538 RICHRC5022 Work Order: F7PTH2AA Report DB ID: 9F7PTH20 C-14 1.79E-01 U 1.46E-01 1.88E*01 3.39E-01 pCIg 100% 0.53 1/26/04 01:171) 2.02 LSI 1.66E-01 2.26E-01 (1.9) G No. of Results: 12 Comments: STL Richland MDCjMDALc Detectlon, Decision Level based on Instrument background or blank, adjusted by the sample Efficlency, Yield, and Volume.rptSTLRchS3mple J Qual
- No Uk< qualifier has been assigned and the result Is below the Reporting Limit, RL (CROL) or Report Value la Estimated.
V4.05 A97 U Qual -Analyzed Irr, but the result is lear than the MdclMdarintal Uncert orgamma scan software did not Identilythe nuclida.
t'._ -( -r.. (,r' fj..C ( *. I. .U ('. " 0atJ b-Feb-s4 Pan Batch: j co Lab Name: STL Richiland Lot-Sample No.: J4A080282-4 Client Sample ID: 9537-0000-014F01 (F5XHM)Result Count Bmelor Gual Error ( 2 s) Ur 1012334 RICHRC5O8O WI AM-241 0.00E+00 U 0.00E+00 4.CM-242 0.00E+00 U 0.OOE+00 6.M-2431244 0.00t+00 U O.OOE+00 4.Total icert( 2 s)ork Order..69E-02.55E-02.73E-02 SAMPLE RESULTS SDG: 24921 Report No.: 24916 COC No.: 2003-00241 MDCIMDA, Rpt Unit, Yield Rst/MDC, Action Lay Lc CRDL(RL) RstrolUcart F7PTJ1AK Report DB ID: 9F7PTJ10 5.19E-02 pCI/9 69% 0.1.03E+00 0.7.25E-02 pCU9 69% 0.0.5.23E-02 pCIg 69%/a 0.1.16E+00 0.--Collectlon Dale: 11/13/2003 10:45:00 AM Received Date: 1/8/2004 12:00:00 PM Matrix: SOIL Ordered by Client Sample ID. Batch Analysis, Total Sa Aliquot Prin Prep Date Size Size Date 1/31/04 04:32 a 0.6026 ALF G 1/31/04 04:32 a 0.6026 ALF G 1/31/04 04:32 a 0.6026 ALP G BSith: 4012336 RICHRC5010 Work Order. F7PTJ1AE Report DB ID: 9F7PTJ10 PU-238 O.OOE+00 U 0.OOE+00 1.30E-01 1.43E-01 pC/g 21% 0. 2/2/04 06:43 p 0.6019 ALP 1.18E+00 0. G PU239140 -1.06E-02 U 2.11E-02 2.13E-02 2.53E-01 pC/g 21% -0.04 2/2l04 06:43 p 0.6019 ALP 5.50E-02 1.07E+00 -0.99 0 Balch: 4012337 RICHRC5010 Work Order: F7PTJIAF Report DB ID: 9F7PTJ10 PU-241 1.33E+01 U 7.52E+00 9.45E+00 1.88E+01 pCVg 21% 0.79 2/6/04 06:27 p 0.6019 LS(7.93E+00 3.48E+01 (2.8) G Batch: 4012340 RICHRC5069 Work Order: F7PTJIAO Report DO ID: 9F7PTJ10 NI-63 2.63E+00 U 2.41E+00 4.13E+00 5.63E+00 pClg 92% 0.47 1/30/04 01:08 a 0.2508 LS(2.73E+00 2.89E+01 (1.3) G Batch: 4012341 FBXZ Work Order: F7PTJ1AH Roport DB ID: 9F7PTJIO FE-55 1.45E+01 U 6.06E+00 1.94E+01 pCI/g 118% 0.75 1/30/04 01:43 p 0.2508 LS(9.25E+00 1.10t+03 (4.8) G STL Rlchland rptSTLRchSample V4.05 A97 MDCIMDA,Lc
-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.J Oual -No UIJ qualifier has been assigned and the result Is below the Reporting Limit, RL (CRDL) or Report Value Is Estimated.
U aual -Analyzed for, but the result Is less than the MdclMdalTotal Uncert or gamma scan software did not Identify the nuctide.
( .-. (..*7 (,- V7-( ( r S P( -( -E --r SAMPLE RESULTS~ ( V~ V. iate.' ib-FebJU4 Lnb Name: STL Rlchland Lot-Sample No.: J4A080282-4 Client Sample ID: 9537-0000-014FO1 (FSXHM)SDG: Report No.: COC No.: 24921 24916 2003-00241 CollectIon Dale: 11/13/2003 10:45:00 AM Received Dati: 1/8/2004 12:00:00 PM Miatrix: SOIL oidered by ClIent Sample ID, Batch t Result Count Total MDCJMDA. Rpt Unit, Yield Rst/MDC, Analysis, Total Sa Aliquot Prim Parameter Qual Error ( 2 ') Uncertl 2 ') ActIon Lev Lc CRDL(RL) Rst/rolUcert Prop Dalt Size Size Dotei Batch: 4012343 RICHRC5078 Work Order: F7PTJ1AC Report DO ID: 9F7PTJIO TC-99 1.18E-01 U 1.05E-01 1.48E-01 2.47E-01 pCVg 100% 0.48 216104 04:19 p 5.0 LS 1.18E-01 5.04E-01 (1.6) G Batch: 4012345 RICHRC5037 Work Order: F7PTJIAJ Reportl D ID: 9F7PTJl0 iH.3 6.59E-02 J 1.53E-02 1.68E-02 2.97E-02 pClg 100% (2.2) 1/20/04 04:01 a 100.1 LSi 1.38E-02 1.65E+01 (7.9) G Batch: 4012347 CMUD Work Order: F7PTJ1AD Report DB ID: OF7PTJ1O 0 SRD90 2.37E*02 U 3.01E-02 3.09E-02 6.43E-02 pC/g 67% 0.37 2/8/04 06:48 t. 6.07 GPC 2.86E.02 6.00E-02 (1.5) G Batch: 4022536 RICHRC5022 Work Orden F7PTJ2AA Report DB 10: 9F7PTJ20 C-14 -3.30E-02 U 1.43E-01 1.82E-01 3.39E-01 pCig 100% -0.1 1/26/04 01:17 p 2.021 LS(1.66E-01 2.26E-01 -0.36 G No. of Results: 12 Comments: STL Richland MDCjMDALc
-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.rptSTlRchSample J Oust -No Ul< qualifier has been assIgned and the result Is below the Reporting Limit, RL (CRt3L) or Report Value Is Estimated.
V4.05 A97 U Oual -Analyzed fzr, but the resultis lass than the Mdc/MdalTotal Uncert or gamma scan software did not Identify the nuclido.
( U 7. ((*(.V -.( ---( ' '- -( ( '_r --. ( ' ' f --( -" Wate:' 16-Feb!-t4
-DUPLICATE RESULTS Lab Name: STL Rlchland SDG: 24921 Collection Date: 11/21/2003 10:12:00 AM Received Date; 1/8/2004 12:00:00 PM Lot-Sample No.: J4A080282-1 Client Sample ID: 9536-0000-012F (F5XD7) DUP Report No.,: 24916 COC No.: 2003-00239 Matrix: SOIL Result, Count Total MDCIMDA, Rpt Unit, RsUMDC. Analysis, Total Sa Aliquot Primar Parameter Orig Rst Qual Error ( 2 a) Uncert( 2 *) Action Lev CRDL Yield RstTolUcert Prep Date Slze Stze Dotectc Balch: 4012334 RICHRC5080 Work Order: F7PRFIAL Report DO ID; F7PRF1LR Orig Sa DB ID: 9F7PRFIO ANM-241 4.36E-02 U 6.16E.02 6.23E-02 S.90E-02 pCVg 77% 0.74 1/31104 04:31 a 0.6029 ALP 12.1.57E-01 J RER2 1.6 1.03E200 (1.4) G CM-242 0.002 00 U 0.OOE-O0 7.21E-02 7.98E-02 pCVg 77% 0. 1/31/04 04:31 a 0.6029 ALP12 O.OOE+O0 U RER2 0.0 0. 0 CM-2431244 O.OOE+00 U 0.00E+00 5.38E-02 5.95E-02 pCI/g 77% 0. 1W31/04 04:31 a 0.6029 ALP12'2.26E-02 U RER2 0.6 1.16Ef0O °. G Alpha Spec Result Sum 4.4E-02 Balch; 4012343 RICHRC5078 WorkOrder:
F7PRF1AM Report DB ID: F7PRF1MR OrIg Se DB ID: 9F7PRF1O TC-99 1.44E-01 U 1.07E-01 1.50E-01 2.48E-01 pCVg 100% 0.58 2/6/04 12:10 p 5.0 LSC4 2.40E-01 U RER2 0.9 5.04E-01 (1.9) G Alpha Spec Result Sum = 4.4E-02 No. of Results: 4 Comments: SiT Rlchland rptSTIRchDupV4.0 6 A97 RER -Replicate Error Raltilo (S-D)/sqritsqCTPUs)tsq(TPUd))1 as defined by ICPT DOA.?.DClh1DA,Lc
-Defection, Decision Level based on Instrument background or blank, adjusted by the sample Efldlency, Yield, and Volume.J Qual -No Ul< qualifier has been assigned and the result Is below the Rcportlng Linitt, RI. (CRlI.) or Report Value Is Estinialcd.
U Qual -Anatyzed for, Iut Sre result Is less thun tic hIedrhidalToual Unccrt or gainma scan surlivare did nut Idemilry the uiciide.
r f _ I F -_ ( __ t _ _ I F( -r -( ; (*
- 1
- r -. ( (' .- I ( -(V (-, V.I- _ F r- -(__._Date: 18 Feb-u4-DUPLICATE RESULTS Lab Name: STL Richland SDG: 24921 Collection Date: 11/21/2003 9:40:00 AM Lot-Sample No.: J4A080282-2 Client Sample ID: 9536-0000-013F (F5XD8) DUP Report No.: 24916 COC No.: 2003.00239 ReceIved Date: 1/8/2004 12:00:00 PM Matrix: SOIL Result, Count Total MDCIMDA, Rpt Unit, Rst/MDC, Analysis, Total Sa Aliquol Prim Parameter Orig Rat aual Error( 2 a) Unced( 2 5) Action Lev CRDL Yield RatJTolUcert Prep Date Size Size DtetS Batch: 4012336 RICHRC5010 Work Order; F7PTD1AL Report DO ID: F7PTD1LR Orig Sa DB ID: 9F7PTD1O PU-238 0.OOE+00 U O.OOE+00 1.39E-01 1.54E-01 pCVg 50% 0. 2/2/04 03:28 p 0.3033 ALP1 O.00E+o0 U RER2 0.0 1.18E+00 0. G PU230/40 0.00E+O0 U 0.00E-t0o 1.39E-01 1.54E-01 pCVg 50% 0. 2/2/04 03:28 p 0.3033 ALPI 0.00E+O0 U RER2 0.0 1.07EtOO 0. G Batch: 4012337 RICHRCS010 WorkOrder:
F7PTD1AM Report DO ID: F7PTD1MR Orig So DB ID: 9F7PTD10 PU-241 9.14E+00 U 6.17EfO0 7.78E+00 1.40E+01 pCIg 50% 0.65 216/04 06:27 p 0.3033 LSC 2.83E+OD U RER2 1.2 3.48E+o1 (2.4) G No. of Results: 3 Comments: STL Rlchland rptSTLRchDupV4.0 5 A97 RER2 -Replicate Error RTatio = (S-D)/sqrI(sq(TPUs)+sq(TPUd))J as defined by ICr? BOA.fDCIh1DA.Lc
-Detectont, Decision Level based on Instrunent background or blank, udjuslcd by Ihe sample Emclency, Yield, and Volunmc.U Qual Anualyzed ter, but the result Is Icss tbhn the MildnfdalTotal Unaert or ganmnSa scn osluivure did not Idenlily the nucilide.
f,- -, r- -I ( --- t- _ -(___I -I r -.f , " ( I_7., r ' -- i-.( "'_ f -r I'_~ tjateFraoFebtU 4-DUPLICATE RESULTS Lab Name: STL Richland SDG: 24921 Collection Date: 11/14/2003 10:45:00 AM Lot-Sample No.: J4AO80282-3 Client Sample ID: 9537-0000-001F (FSXFG) DUP Report No.: 24916 COO No.: 2003-00241 Received Date: 1/8/2004 12:00:00 PM Matrix: SOIL Result, Count Total MDCIMDA, Rpt Unit, Rst/MDOC, Analysis, Total Sa Aliquot Primal Parameter Orig Rst Oual Error ( 2 S) Uncert( 2 ) Action Lev CRDL Yield RatlTotUcart Prop Date Size Size Detach, Balch: 4012345 RICHRC5037 Work Order: F7PTH1AM ReportDB ID: F7PTH1MR Orig Sa DO ID: 9F7PTH1O H-3 1.87E-02 U 1.45E-02 1.57E-02 3.86E-02 pCI/g 100% 0.48 1120104 03:19 a 100.1 LSC4 2.12E-02 U RER2 0.2 1.65E+01 (2.4) G Batch: 4022538 RICHRC5022 Work Order: F7PTH2AL Report DB ID: F7PTH2LR Orig Sa DB ID: 9F7PTH20 C-14 1.47E-01 U 1.45E-01 1.07E-01 3.39E-O1 pCI/g 100% 0.43 1/26/04 01:17 p 2.021 LSC5 1.79E-01 U RER2 0.2 2.26E-01 (1.6) G No. of Results: 2 Comments: STL Richland rplSTLRchDupV4.0 5 A97 RER2 .Replicate Error Rtollo (S.fl)4sqrlq(TPUs)+sq(TPUd))I as denned by 1CPT BOA.hfDCqhDA,Le
-Dclection, Decision Level llasCd on Instrument background or blank, adjusted by the sanmplo Emclency, Vield, Dnd Volume.U QuDl
- AnaIyzed for, but the result Is less lual the filc/N'dualTotal Uncert or guninum scan sorthare did not Ideffliry hlic nuCide.
- -r -[77 I --*T (i[_'_. VI F. C **'
- C-.. ' C7 I.rs [: I 17- I; *' I I~ t:,U e.DUPLICATE RESULTS Lab Name: STL Richland SDG: 24921 Collection Date: 11/13/2003 10:45:00 AM Lot-Sample No.: J4A080282-4 Report No.: 24916 COC No.: 2003-00241 Received Datu: 1/812004 12:00:00 PM Client Sample ID: 9537-0000-014F01 (F5XHM) DUP Matrix: SOIL Result, Count Total MDCJMDA, Rpt Unit, RsUMDC, Analysis, Total Sa Aliquot Primal Parameter Orig Rst auil Error ( 2 a) Uncert( 2 a) Action Lev CRDL Yield RstrTolUcert Prep Date Ska size Delech Batch: 4012340 RICHRC5069 Work Order: R7PTJ1AL Report DO ID: F7PTJ1LR Orig So Do ID: 9F7PTJ10 NI-63 3.86E+00 U 2.28E+00 3.96E-t00 5.27E+OO pCVg 99% 0.73 1/30/04 02:50 a 0.2519 LSC3 2.63E+00 U RER2 0.4 2.89E+O1 (2.) G Batch: 4012341 FBXZ Work Order: F7PTJ1AM Report DS ID: F7PTJ1MR Orig Sa DO ID: 9F/PTJIO FE-55 4.99E+00 U 5.30E+00 1.76E+01 pCLg 90% 0.28 1/30/04 01:43 p 0.2519 LSC7 1.45Et01 U RER2 2.4 1.10EiO3 (1.9) G Batch: 4012347 CMUD WorkOrder:
F7PTJtAN ReportDRID:
F7PTJINR Orig a DB ID: 9F7PTJ1O SR-Do 2.73E-02 U 3.30E-02 3.38E-02 7.03E-02 pCVg 68% 0.39 2/8/04 06:49 a 6.07 GPC4/2.37E-02 U RER2 0.2 6.00E02 (1.6) 0 No. of Results: 3 Comments: STL Richland rptSTLlchtupV4.0 S A97 RER1 .Repilcate Error Ratio = (S-D)/fsqrt(sq(TPUs)+sq(TPUd))I as delined by JCPT IIOA.tMl)qCNfDA,Lc
-Detection, Decislon vdel based on instrument background or blank, adJuvted hy the sample EMcnency, Yield, amld Volume.U Quul -Analyzed ror, hIut the rcsult :; less thon ihe Mrdecldarrotal UIncert or gamwism sctUI sorlivarL did not Id..irly the nucilde.
f -, I ( -" I"-- -f --'.- F -, r- -r., -(" , f .OFI ,l I -r f- ( (-:. ( V-. (--Date: 16-Feb-04 BLANK RESULTS Lab Name: STL Richland Matrix: SOIL SDG: 24921 Report No.: 24916 Count Total MDCIMDA, Rpt Unit, Rst/MDC, Analysis, Total Sa Aliquot Primar Parameter Result Qust Error ( 2 8) Uncert( 2 a) Lc CRDL Yield RstTottUcert Prep Date Size Size Delecic Batch: 4022536 RICHRC5022 Work Order: F7VCP2AA Report D3 ID; F7VCP2AB C-14 2.73E-02 U 5.83E-02 7.47E-02 1.37E-01 pCUg 100% 0.2 1/26/04 01:17 p 5.0 LSCI 6.73E.02 2.26E-01 0.73 G Batch: 4012340 RICHRC5069 Work Order: F7VCT1AA Report D0 ID: F7VCT1AB NI-63 2.44E+00 U 2.55E+00 4.32E+00 6.18E2+00 pCI/g 90% 0.4 1/30/04 04:33 a 0.25 LSC3 2.99EtO0 2.89E+01 (1.1) G Batch: 4012334 RICHRC50O8 WorkOrder:
F7VCGIAA ReportDBID:
F7VCG1AB AM-241 O.OOE+00 U O.OOE+00 1.76E-02 1.95E-02 pCVg 66% 0. 1/31/04 04:33 a 2.0 ALP13 CM 1.03E+00 0. G CM-242 O.OOE+00 U O.OOE+00 2.37E-02 2.63E-02 pCVg 66% 0. 1/31/04 04:33 a 2.0 ALP13 0. G CM-243244 O.OOE+0O U 0.00E+00 1.77E-02 1.96E-02 pCI9 66%o 0. 1/31104 04:33 a 2.0 ALP13 1.16E+00 0. G Batch: 4012336 BICHRC5010 Work Order: F7VCMlAA Report D0 ID: F7VCMIAB PU-238 0.OOE+00 U O.OOE+00 2.1 BE.02 2.38E.02 pCI/g 47% 0. 2/2/04 06:43 p 2.0 ALP131 1.18E+00 0. G PU239(40 -1.76E.03 U 3.52E.03 3.53E-03 4.21E-02 pCig 47% -0.04 2/2/04 06:43 p 2.0 ALP131 9.14E-03 1.07Et00 -1. G Batch: 4012337 RICHRC5010 Work Order: F7VCN1AA ReportDR ID; F7VCN1AO PU-241 1.46E+00 U 1.00E+00 1.25E+00 2.30E+00 pCVg 47% 0.64 2/6/04 06:27 p 2.0 LSC7 1.08E+00 3.48E+01 (2.3) G Batch: 4012343 RICHRCS078 WorkOrder:
F7VCIIAA ReportDB ID: F7VC13AD QI 1. Richlana rptSTI-Rch~lank V4.05 A97 MDUCIMDA,Lc
-Detection, Decision Level based on Instrument background or blank, adjusted by the sample Efficiency, Yield, and Volume.U Qual .Analyzed ror, but the result Is less than the Mdc/lfdalTolul Uncerl or gamnma scan soriware did not Idenlify the nucilde.
( .. f .-. .f. .. ... .( r. f *': v I. r. I I --. ORL.G.-I. D a ( --- F e -Date: l16-feb-04 BLANK RESULTS Lab Name: STL Richland Matrix: SOIL SDG: 24921 Report lo.: 24916 Count Total MDCIMDA, Rpt Unit, RsVMDC, Analysis.
Total So Aliquot Prlmal Parameter Result Oual Error ( 2 s) Uncerl( 2 s) Lc CRDL Yield RsVTolUcert Prep Date Size Size DalOec TC.99 2.56E-01 J 1.10E-01 1.56E-01 2.48E101 pCVg 100% (1.) 2/6/04 05:21 p 5.0 LSC'1.19E-01 2.OOE+01 (3.3) G Batch: 4012345 RICHRC5037 WorkOrder:
F7VC31AA Report 08 ID: F7VC31AB Fl-3 6.13E-02 U 1.09E-01 1.23E-01 2.65E-01 pCI/g 100% 0.23 1/19/04 11:46 p 10.0 LSC4 1.23E-01 1.65E+01 (1.) G Batch: 4012347 CMUD Work Order: F7VC7IAA Report D0 ID: F7VC71AB SRn-o 6.59E-03 U 1.71E-02 1.71E-02 3.74E-02 pCVg 76% 0.18 2/8/04 06:49 a 10.0 GPC41 1.68E.02 6.00E-02 0.77 G Batch: 4012341 FBXZ Work Order: F7VCX1AA Report D0 ID: F7VCX1AB FE-55 7.88E+oO U 5.48E+00 1.48E+01 pCVg 85% 0.53 1/30/04 01:43 p 0.25 LSC7 7.05E+00 1.10E+03 (2.9) G Ho. of Results: 12 Comments: STL Rlchland MDCIMDA.Lc
-Detection.
Decision Leval hamad on Instrumont hackornund or blank. adlusInted by the nampla Mftiencv.
Yleld. and Volume.rptSTI.Rch~iank V4.05 A97 J Qual -No UVI qualilfer has been assigned and the result Is below IMe Reporting Limil, Il. (CRI)i.) or Report Vaute Is Esilmated.
U Qual -Anulyecd for, but dic result Is less ham tiMe MtdcAdMIT'ltal Uncerl or gammu scanm sofiwure did POt Idetllry Ilie niullde.
U--- (-- C----( 7 ((- -1.. C (. .-r' .Cc , ~ -U:- , -(77 FOF:M if Date: 16-Feb-04 LCS RESULTS Lab Name: STL Richland Matrix: I SOIL SDG: 24921.Report No.: 24916 Count Total Report Expecled Recovery, Analysis, Aliquot Prim;Parameter Result Oual Error ( 2 6) Uncert(2 a) MDCIMDA Unil Yield Expccted Uncert laies Prep Date Size Delec Batch: 4022533 RICHRC5022 Work Order: F7VCP2AC Report Do ID: F7VCP2CS C-14 7.34E+00 1.33E-01 2.95E-01 1.37E-01 pCVg 100% 7.282+00 2.35E-01 101% 1/26104 01:17 p 5.0 LSt Rec Limits: 70 130 0.0 G Batch: 4012340 RICIRCSO69 Work Order: F7VCT1AC Report DB ID: F7VCTICS Nl-83 4.80E+02 8.94E+00 7.58EfOl 6.61E+00 pCI/9 89% 5.0BE402 1.70E+01 95% 1/30/04 06:15 a 0.25 LS(Rec Limits: 70 130 .0.1 G Batch: 4012334 RICHRC50,0 Work Ordern F7VCGIAC Report OB ID: F7VCGICS AM-241 4.27E+00 2.95E-01 8.16E-01 1.3BE-02 pClg 88% 4.54E+00 1.53E-01 94% 1/31/04 04:33 a 2.0 ALP1 Rec Limils: 70 130 -0.1 G Batch: 4012338 RICHRC5010 Work Order: F7VCM1AC Report DB ID: F7VCM1CS PU239140 5.35E-01 1.14E-01 1.46E-01 1.652-02 pC/g 54% 4.61E-01 2.32E-02 116% 2/2/04 06:44 p 2.0 ALPI Rec Limits: 70 130 0.2 G Batch: 4012337 RICHRC5010 Work Order: F7VCNlAC Report DS ID: F7VCNlCS PU-241 1.89E+01 1.49E+00 2.30E+00 1.97E+00 pCIg 54% 2.28E+01 1.03E+00 83% 2/6/04 06:27 p 2.0 LSC Rec Limits: 70 130 -0.2 G Batch: 4012343 RICHRC5078 WorkOrder:
F7VC11AG Report DB ID: F7VC1ICS TC-99 1.32E+01 3.30E-01 9.21 E-01 2.49E-01 pCVg 100% 1.36E+01 3.04E-01 97% 2/6/04 06:24 p 5.0 LSC Roec LImits: 70 130 0.0 G Batch: 4012345 RICHRC5037 Work Order: F7VC31AC Report DB ID: F7VC31CS 1H-3 2.72E+00 2.19E-01 2.44E-01 2.63E-01 pCI/g 100% 2.75E+00 8.25E-02 99% 1/20/04 12:28 a 10.0 LSC Rec Limits: 70 130 0.0 G Batch: 4012347 CMUD Work Order: F7VC71AC Report De ID: F7VC7ICS STL Rlchland Big$s -(ItciuIiIxpected)-l na denned by ANSI Nl3.30.rpISThRclILcs V4.05 A97
( V [ ( ( ( eOR4MI(l( Date: 16-Feb*04 LCS RESULTS Lab Name: Matrix: STL RIchland SOIL SDG: 24921 Report No.: 24916 Count Total Report Expected Recovery, Analysis, Aliquot Prima Parameter Result Qual Error ( 2 a) Uncert(2 a) MDCjMDA Unit Yield Expectcd U(iccrt WIlus Prep Date Size Detect SR*90 5.01E-01 4.66E-02 8.57E-02 3.64E.02 pC/g 78% 4.61E-01 5.60E.03 109%/6 2/8104 06:49 a 10.0 GPC Rea Limits: 70 130 0.1 G Batch: 4012341 FBXZ Work Order: F7VCX1AC Report DB ID: F7VCX1CS FE-55 5.98E+01 1.29E+01 1.49E+01 pCt/g 85% 5.40E+01 2.88E+00 111% 1/30/04 01:43 p 0.25 LSC Rec Limits: 70 130 0.1 G No. of Results: 9 Comments: co STL Richland Ilias -(csiilMlExpected)-i as dellncd by ANSI N13.30.rptSTLRchLca V4.05 A97 (C r (. r -."(7 I _ (.I j ( ( -*( -(MATRIX SPIKE RESULTS ( -(...( _ -(-,,utile:
fio-rob -8 Lab Name: STL Richland Lot-Sample No.: J4AO80282-2 SDG: 24921 Report No.: 24916 Matrix: SOIL SpikeResult, Count Total Rpt Unit, Rec- Exp- Exp Analysis, Aliquot Prim Parameter Orig Rst Qual Error (2 s) Uncerl(2 s) MDCIMDA CRDL Yield overy ected Uncert Prep Date Size Dotea Batch: 4012343 RICHRCS078 Work Order: F7PTD1AN Report Do ID: F7PTDINW Orig Sa oB ID: 9F7PTD10 TC-99 2.51E+01 4.47E-01 1.65E+00 2.49E-01 pCig 100% 92.30% 2.72E+01 ;.11E-01 2/6/04 02:14 p 5.0 LS(1 t.67E-01 RER2 No. of Results: 1 Comments: CD STL Richland rplSTLRchMs V4.05 A97 RER -Replicate Error Ratio (S-D)sqrt(sq(TPUs)+sq(TPUd))j as deflned by ICPT BOA.Bias -(Rasuit/Expected)-1 as defined by ANSI N13.30.
Page 1 of I II i Kallsen, There sa _-555633 Hollenbeck
[Hollenbeck@CYAPCO.coml (J From: Peter D.-Sent: 'Nednesday.
January 07, 2004 11:33 AM To: Kallsen, Theresa Cc: John McCarthy; Jim M. Limbert
Subject:
Samples for hard-to-detect'radionuclides
_ .Good afternoon-Sa ( k f Please ainalyze the following samples: 1 9536-0000-012
-1 %1 IO[2 0 0'3 O°2 (& 9536-0000-013F-
'a 953-7-0000-0140 1 F 1V3 a q9,537000oo-0 4f(? 6 1 3]~ I k? LO3MOX1 ra))63xF;D for the radionuclides in column 6 of the attached Table I to the corresponding RDLs listed in Table 20 of CY's SOW.If you have any questions, please call me at 860-267-3923.
Thanks, Pete.Lg --I.lul-ODA&0?>g) 1% -4 1 ~C-0 01)FqPID (1 7 Q2 C1 vil vI I I II i I I i.-II I I i 30 I fS1/2004 Table 1!_Cnlumnl I Culumn 2 Column 3 Column 4 Column S Column 6 Column 7 Column 8 Iilu .nW rDFSSGANI FSSALL FSSHTD FSSTRU FSSOTHR Rdidomnudich SoI I NDC Watcr MDC CHGAM CHALL CfIHTD CHTRU CHO'rHR I (1w g) (p i/) Note I Note I Note I Note I Note 2 11-3 17.5 26080 4 4 r C- 14'/ 0.23 360 Y 4 Sin-54 0.70 968 Y 1* Fe*55 /1 1095 2616 1 4 Co*60 0.15 45 _ _ 4\y-103ni 0.29 169 4 Ni23 2S.9 1260 4 4 Sr-90 J I 0.06 10 4 4 Nb-94 , 0.28 270 4 .4 Irc 99 'f 0.5 1056 4 4 Cs-l34 0.19 13.6 4 '4 Cs.137 0.32 17.2 4 4 I.Eu.152 0.4 29344* Eu-154 0.37 202 .Y4 Eu-155 15.7 1300 4 'Pu-23S .IS 0.6. 4 4 4J PIu-739P-40 1.07 0.54 4 4 4 34.2 28 '4 _Am41 1.03 0.53 _ 44 4 4 Cm-243/244, 1.16 0.78 4 4 4 K-40 N/A NIA 4 4 Tn-2os N/A N/A 44 BH.212 NIA N/A v Pb-212 N/A NIA Bi 214 NrA N/A ' '1 _Pb-214 NIA N/A 4 ' _ _ _Ra-226 N/A NIA l ' ' __At-228 NIA N/A l '4 41 31 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD Attachment 2c Sample and Scan Area Data (1 Pages)
Survey Release Record Scan Area Results Survey Unit 9537-0000 9537-0000 SCAN AREA # I SECTION 1-13 REPORT 11/1 1f2003 Background Action Reading Log E-600 Probe Survey Location (cpm) Level (gross Log Date Time SIN SIN_____ _____ (cpm ) cp ni) __ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _9537-00-001-BC-001 0 6230 1111112003 11:40:00 1112 1005 9537-00-001-BC-001
.0 7250 11/11/2003 11:51:00 1112 1005 9537-00-001-SC-001 7250 8465 6850 11/1112003 11:58:00 1112 1005 9537-00-001-SC-003 7250 8465 8090 11/1112003 12:02:00 1112 1005 9537-00-001 -SC-005 7250 8465 7200 11/11/2003 12:06:00 1112 1005 9537-00-001-SC-007 7250 8465 6640 11/11/2003 12:12:00 1112 1005 9537-00-001-ER-001 7250 8465 9430 11,11(2003 14:28:00 1112 1005 9537-00-001-SC-009 7250 8465 6020 1111 1/2003 14:32:00 1112 1005 9537-00-001.SC-011 7250 8465 6270 11/1112003 14:48:00 1112 1005 log10 ER-6 7250 8465 15200 11/1112003 14:53:00 1112 1005 9537-00-001-SC-013 7250 8465 7060 11/11/2003 15:00:00 1112 1005 9537-00-001-BC-002 0 7560 11/1112003 11:36:00 1106 1007 9537-00-001-SC-002 7560 8801 7750 11/1112003 11:50:00 1106 1007 9537-00-001-SC-004 7560 8801 7570 11/1 112003 11:56:00 1106 1007 9537-00-001-SC-006 7560 8801 7390 11/1112003 12:00:00 1106 1007 9537-00-001-SC-008 7560 8801 7790 11/1 112003 12:08:00 1106 1007 9537-00-001 -ER-002 7560 8801 9520 11/1112003 14:25:00 1106 1007 9537-00-001-ER-003 7560 8801 9670 11/1112003 14:29:00 1106 1007 9537-00-001 -ER.004 7560 8801 9870 11/1112003 14:33:00 1106 1007 9537-00-001.SC-010 7560 8801 7250 11/1112003 14:34:00 1106 1007 Log# 10 ER-5 7560 8801 9630 11/1112003 14:39:00 1106 1007 Log#l l 9537-00-001-SC-012 7560 8801 7570 Il/ 112003 14:49:00 1106 1007 9537-0000 SCAN AREA # I SECTION 14-29 REPORT 11/12/2003 Background Action Reading Log E-600 Probe Survey Location (cpm) Level (gross cpm) Log Date Time S/N S/N 9537-00-001-BC-003
-0 7060 11/12/2003 15:02:00 1112 1005 9537-00-001-SC-014 7060 8259 7210 11/12/2003 15:08:00 1112 1005 9537-00-01-SC-016 7060 8259 7120 11/12/2003 15:14:00 1112 1005 9537-00-001-SC-018 7060 8259 7010 11/1212003 15:29:00 1112 1005 9537-00-001-SC-020 7060 8259 7180 11/12/2003 15:34:00 1112 1005 9537-00-001-SC-022 7060 8259 8080 11/12/2003 15:40:00 1112 1005 9537-00001-SC-024 7060 8259 6980 11/1212003 15:45:00 1112 1005 9537-00-001-SC-026 7060 8259 6710 11/1212003 15:53:00 1112 100 9537-00-001 -SC-028 7060 8259 6810 11/1212003 16:03:00 1112 1005 9537-00-001-BC-004
-0 8000 11/1212003 14:58:00 1106 1007 9537-00-001-SC-015 8000 9276 7640 11/1212003 15:03:00 1106 1007 9537-00-001-SC-017 8000 9276 7650 11/1212003 15:09:00 1106 1007 9537-00-001-SC-019 8000 9276 6950 11/12/2003 15:25:00 1106 1007 95374-0001-SC-021 8000 9276 7510 11/1212003 15:30:00 1106 1007 9537-00-001-SC-023 8000 9276 7090 11/1212003 15 35:00 1106 1007 9537-00-001-SC-025 8000 9276 7320 11/1212003 15:41o00 1106 1007 9537-00-001-SC-027 8000 9276 7180 11/12/2003 15:47:00 1106 1007 Log 9 ER # 7 8000 9276 10300 11/12/2oo3 15:56:00 1106 1007 Log 10 9537-00-001-SC-029 8000 9276 7670 11/12/2003 15:59:00 1106 100 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD Attachment 2d Split Sample Assessment Forms (2 Pages)
Health Physics Procedure 24265-000-GPP-GGGR-R5124-000-Rev.CY-000 Attachment A Health Physics Procedure.
24265-000-GPP-GGGR-R5 I 24-000-Rev.CY-000 Attachment A Split Sample Assessment Form Survey Area#: 9537 lSurvey Unit #: 0000 ISurvey Unit name: Permitted Landfill Sample Plan or WPIR#: 24265-000-GEN-0000-00134-000 SML#: 9537-0000-003 Sample
Description:
Comparison of split samples collected from sample measurement location #3 and analyzed using gamma spectroscopy by off-site Vendor Laboratory.
The standard sample was 9537-0000-003F, the comparison sample was 9537-0000-003FS.
STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (YIN)Cs-137 4.03E-2 1.54E-2 3 3.86E-2 1.33E-2 0.9 N K-40 9.68 7.85E-1 12 0.6- 1.66 10.4 7.85E-1 1.0 Y Ra-226 5.32E-I 7.05E-2 8 0.6 -1.66 6.07E-1 6.45E-2 1.1 Y Comments/Corrective Actions: Reported cesium-137 Table is provided to show acceptance concentrations were too low to effectively perform criteria used to assess split samples.comparison.
Performed split sample comparison using potassium-40 (K40) and radium-226 (Ra-226).
4 -7 0.5 -R2.0 Potassium-40 and radium-226 comparisons satisfactory.
8 -15 0.6 -1.66 16 -50 0.75 -1.33 51 -200 0.80 -1.25>200 0.85 -1.18 Performed By: Date Reviev Date: 2.i I,-Page 1 of 2 Health Physics Procedure 24265-000-GPP-GGGR-R5 124-000-Rev.CY-000 Attachment A Health Physics Procedure 24265-000-GPP-GGGR-R5 1 24-000-Rev.CY-000 Attachment A Split Sample Assessment Form Survey Area#: 9537 l Survey Unit #: 0000 Survey Unit name: Permnitted Landfill Sample Plan or WPIR#: 24265-000-GEN-0000-00134-000 l SML#: 9537-0000-006 Sample
Description:
Comparison of split samples collected from sample measurement location #6 and analyzed using gamma spectroscopy by off-site Vendor Laboratory.
The standard sample wvas 9537-0000-006F, the comparison sample was 9537-0000-006FS.
STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (Y/N)Cs-137 1.74E-2 1.44E-2 I -8.92E-3 1.18E-2 __ N K-40 8.97 7.45E-1 12 0.6- 1.66 10.4 8.15E-1 1.2 Y Ra-226 4.71E-1 7.90E-2 6 0.5-2.0 5.51E-1 5.85E-2 1.2 Y Comments/Corrective Actions: Reported cesium-137 Table is provided to show acceptance concentrations were too low to effectively perform criteria used to assess split samples.comparison.
Performed split sample comparison using Resolution Agreement Ranie potassium40 (K40) and radium-226 (Ra-226).
4 -7 0.5 -2.0 Potassium40 and radium-226 comparisons satisfactory.
8- 15 0.6 -1.66 16 -50 0.75 -1.33 51 -200 0.80 -1.25>200 0.85 -1.18 P fo B Date ew Date: 720 oj- x h"'7-Page 2 of 2 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD Attachment 2e Preliminary Data Review Forms (1 Pages)
Heath Physics Procedure 24265-000-GPP-GGGR-R5123-000-Rev.CY-000 Attachment B PRELIMINARY DATA REVIEW FORM -SAMPLES FOR THE SIGN TEST Survey Unit: 9537-0000 Survey Unit Name: Permitted Landfill Classification:
2 Survey Media: Soil Type of Survey: Final Status Survey Type of Measurement:
Radionuclide Specific Number of Measurements:
15 Operational DCGL (pCi/g) 3.16E+00 BASIC STATISTICAL QUANTITIES Cs-137 Minimum Value: -2.90E-03 Maximum Value: 8.33E-02 Mean: 2.93E-02 Median: 2.02E-02 Standard Deviation:
2.73E-02'1J z NUMBER 9537-0000-001 F 8 9537-0000-002F 8 9537-0000-003F 4 9537-0000-004F I 9537-0000-005F0I I 9537-0000-006F 1 9537-0000-007F01 9 9537-0000-008F
-6 9537-0000-009F 2 9537-0000-01IOF
-2 9537-0000-01 lFO1 3 9537-0000-012F 8 9537-0000-013F 2 9537-0000-014F01 6 9537-0000-015F 2 (X~Z (?t.Oaz RADIONUCLIDE CONCENTRATION (pCi/g)Cs-137 Identified?
.33E-02 Y.24E-02 Y.03E-02 Y.87E-02.50E-02.74E-02.98E-03 6.84E-04.02E-02 2.90E-03.38E-02 Y.50E-03.64E-02.40E-02 Y.34E-02 1 of 3
- PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD Attachment 2f Graphical Representation of Data (2 Pages)
Health Physics Procedure 24265-000-GPP-GGGR-R5123-000-Rev.CY-000 Attachment C health Physics Procedure 24265-000-GPP-GGGR-R5 1 23-000-Rev.CY-000 Attachment C FREQUENCY PLOT FOR CESIUM-137 Survey Unit: Survey Unit Name: Mean: 9537-0000 Permitted Landfill 0.0293 pCi/g 6 -.-5-0.0000 0.0125 0.0250 0.0375 0.0500 0.0625 0.0750 0.0875 Upper End Value (pCi/g)Upper End Observation Observation Value Frequency Frequency 0 2 13%0.0125 2 13%0.025 5 33%0.0375 2 13%0.05 1 7%0.0625 0 0%0.075 1 7%0.0875 2 13%Total: 15 100%2.. ca6r., Page I of 2 Quantile Plot for Cobalt-60 Survey Unit: 9537-0000 Survey Unit Name: Permitted Landfill Quantile Plot For Cobalt-60 2.OOE-02 1.50E-02 1.OOE-02 c., 5.OOE-03 c O.OOE+00 0 a=. -5.OOE-03 C -1.OOE-02 U C -1.50E-02 0° -2.OOE-02-2.50E-02-3.OOE-02 1 I I } 1-] .- I t1 .-*-~- --1-m N---I I ---, I L. I ..0 20 40 60 80 100 Percentage Co-60 Rank Percentage
-1.38E-02 1 3%-1.22E-02 2 10%-1.19E-02 3 17%-1.041-02 4 23%-7.25E-03 5 30%7.12E-03 6 37%8.77E-03 7 43%9.25E-03 8 50%0 9.90E-03 9 57%1.04E-02 10 63%1.20E-02 11 70%/s 1.25E-02 12 77%1.33E-02 13 83%1.39E-02 14 90%1.59E-02 15 97%Subbmitted by/Date Reviewed by/Date Health Physics Procedure 24265-000-GPP-GGGR-R5123-000-Rev.CY-000 Attachment C QUANTILE PLOT FOR CESIUM-137 Survey Unit: 9537-0000 Survey Unit Name: Permitted Landfill Mean: 2.93E-02 pCi/g 9.OOE-02-.-
-,-- ---7.OOE-02 .-,. -..5.OOE 02 ' 2, -3300E02 -..:.. i -, :. '-1.EE102 9.98E-03 4 23%1.50E402 5 30%1.74E-02 6 37%1.87E-02 7 43%2.02E-02 8 50°K 2.342-02 9 57%2.64E-02 10 63%3.38E-02 11 70%4.03E-02 12 77%6.40E-02 13 83%8.24E-02 14 90%8.33E-02 15 97%Submitted By/Date Reviewed By/Date Page 2 of 2 PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD Attachment 2g Sign Test Calculation (1 Pages)
Health Physics Procedure 24265-000-GPP-GGGR-R5121I -OOO-Rev.CY-OOO Attachment A Health Physics Procedure 24265-000-GPP-GGGR-R5 121 -000-Rev.CY-000 Attachment A Sign Test Calculation Sheet For A Single Radionuclide Survey Unit Number: 9537-0000 Survey Unit Name: Permitted Landfill Area WP&IR#: 24265-000-GEN-0000-00134-000 Classification:
2 TYPE I (a error): 0.05 TYPE II (,B error): 0.05 Radionuclide:
Cesium-137 Survey Design DCGL (pCi/g): 3.16 Results (pCi/g) DCGL -Results Sign 8.33E-02 3.08E+00 1 8.24E-02 3.08E+00 1 4.03E-02 3.12E+00 1 1.87E-02 3.14E+00 I 1.50E-02 3.15E+00 I 1.74E-02 3.14E+00 1 9.98E-03 3.15E+00 1-6.84E-04 3.16E+00 1 2.02E-02 3.14E+00 1-2.90E-03 3.16E+00 I 3.38E-02 3.13E+00 I 8.50E-03 3.15E+00 1 2.64E-02 3.13E+00 1 6.40E-02 3.1 OE+00 1 2.34E-02 3.14E+00 I Number Of Positive Differences (S+): 15 Critical Value: II Performed By:_Independent Review Bya Z (_Survey Unit: Meets Acceptance Criterion D a te : _ _ _ _ _ _ _ _ _ _ _ ' _Date: ,/) ,/aY//Page 1 of I PERMITTED LANDFILL SURVEY UNIT 9537-0000 RELEASE RECORD Attachment 2h COMPASS DQA Surface Soil Report With Retrospective Power Curve (2 Pages).
DQA Surface Soil Report Assessment Summary I I I I I Site: Planner(s):
Survey Unit Name: Report Number: Survey Unit Samples: Reference Area Samples: Test Performed:
Judgmental Samples: Assessment
==
Conclusion:==
Survey Unit 9537-0000 J. McCarthy Permitted Landfill Area*1 15 0 Sign Test Result: Not Performed 0 EMC Result: Not Performed Reject Null Hypothesis (Survey Unit PASSES)Retrospective Power Curve 2 I 0.9.0.8 I .0.7 2 0.6._ 0.5~0.3' OS c0.2 ad 0.1 a 0A 0 I_ __I I 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Soil Comnamh (Ci/g), hcIndhug bhackgxuuxl Prospective Power
- 1-beta ---- Actual Power-LBGR --Estimated Power-DCGL -- -Retrospective Power 3.5 CO#COMPASS v.0.70 IM7/2005 Page 1 DQA Surface Soil Report Survey Unit Data NOTE: Type = "S' Indicates survey unit sample.Type = 'R' Indicates reference area sample.Sample Number 9537-0000-001 F 9537-0000-002F 9537-0000-003F 9537-0000-004F 9537-0000-005F01 9537-0000-006F 9537-0000-007F01 9537-0000-008F 9537-0000-009F 9537-0000-01OF 9537-0000-01 1 F01 9537-0000-012F 9537-0000-013F 9537-0000-014F01 9537-0000-015F Type S S S S S S S S S S S S S S S Cs-I37 (pCI/g)0.08 0.08 0.04 0.02 0.02 0.02 0.01 0 0.02 0 0.03 0.01 0.03 0.06 0.02 Basic Statistical Quantities Summary Statistic Survey Unit Backaround DOO Results Sample Number Mean (pC/g)Median (pCI/g)Std Dev (pCVg)High Value (pCI/g)Low Value (pCI/g)15 N/A N=15 0.03 N/A 0.04 0.02 N/A N/A 0.03 N/A 0.0252 0.08 0.00 N/A N/A N/A NUA COMPASS vl.0.0 111712005 Page 2 COMPASS v1.0.0 111712005 Page 2