ML060320124
| ML060320124 | |
| Person / Time | |
|---|---|
| Site: | Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png (DPR-061) |
| Issue date: | 12/05/2005 |
| From: | Adams W Oak Ridge Institute for Science & Education |
| To: | Tanya Smith NRC/NMSS/DWM |
| References | |
| RFTA 03-008 | |
| Download: ML060320124 (3) | |
Text
M C
PR I S HE OAK RIDGE INsrTrTUr FOR SCIENCE AND EDUCATICON December 5, 2005 Mr. Theodore Smith MailStop: T-7F27 Division of Waste Management U.S. Nuclear Regulatory Commission 11545 Rockville Pike Rockville, MD 20852
SUBJECT:
REPORT FOR ANALYSIS OF SOIL AND MISCELLANEOUS SAMPLES FROM THE CONNECTICUT YANKEE HADDAM NECK PLANT, HADDAM, CONNECTICUT [DOCKET NO. 50-0213; RFTA NO. 03-0081
Dear Mr. Smith:
The Environmental Survey and Site Assessment Program (ESSAP) of the Oak Ridge Institute for Science and Education (ORISE) received fifteen soil samples and eleven miscellaneous (concrete) samples that were collected during the period of November 17, 2004 to July 21, 2005 at the Connecticut Yankee Haddam Neck Plant in Haddam, Connecticut. These samples were collected by Connecticut Yankee Atomic Power Company (CYAPCO) personnel. At the request of the U.S. Nuclear Regulatory Commission (NRC), these samples were submitted to the ESSAP laboratory and analyzed by gamma spectroscopy (Procedure CP1, Revision 15) for Co-60, Cs-137, Eu-152, Eu-154, and Eu-155 and by wet chemistry analyses for H-3 (Procedure AP6, Revision 15) and Sr-90 (Procedure AP4, Revision 13). The radionuclide concentrations for these samples are provided in Table 1.
ESSAP's Quality Control (QC) requirements were met for these analyses. The QC files are available for your review upon request.
If you have any questions or comments, please eirect them to me at (865) 576-0065 or Scott Kirk at (865) 574-068:5.
S' rely_
Wade C. Adams Health Physicist/Project Leader Environmental Survey and Site Assessment Program WCA:db Enclosure cc:
'. McLaughlin, NRC/NMSSTfWFN T-'7E18 E. Abelquist, ORISE/ESSAP E]. Knox-Davin, NRC/NMSS/TWFN 8A23 S. Kirk, ORISE/ESSAP L. Kauffman, NRC/Region I M. Miller, NRC/Region I J. Kottan, NRC/Region I File/0857 Distribution approval and concurrence:
Initials Technical Management Team Member l
H Laboratory Manager Quality Manager GYAT P. 0. BOX 117, OAK RIDGE, TENNESSEE 37831-0117 Operated by Oak Ridge Associated Universities for the U.S. Department of Energy
TABLE 1 0
CD a
0 0
v 0I 0~
0 tj)
RADIONUCLIDE CONCENTRATIONS IN SOIL AND MISCELLANEOUS SAMPLES SUBMITTED TO ESSAP BY THE NRC CONNECTICUT YANKEE HADDAM, CONNECTICUT Sample Collected Radionuclide Concentrations (pCi/g)
Identification Date Time H-3 Co-60 Sr-90 Cs-137 Eu-152 Eu-154 Eu-155 Soil Samples 89 3/16/05 1517 1.91.5b 0.06+0.05 0.03+0.22 0.00c 0.11 0.00+0.10
-0.13+0.22 0.03+0.06 90 3/16/05 1532 0.5 +/- 1.4 0.01 + 0.02 0.01 +/- 0.23 0.02 + 0.03
-0.02 + 0.03
-0.03 + 0.07 0.01 +/- 0.02 91 11/17/04 1100 5.3 +/- 1.6 0.02 +/- 0.03
-0.04 +/- 0.24 0.04 + 0.03 0.01 + 0.06
-0.02 + 0.13 0.03 +/- 0.04 92 11/17/04 1100 6.6 1.6 0.02 + 0.05
-0.04 + 0.24
-0.02 0.09 0.00 0.10
-0.22+ 0.21 0.03 + 0.05 93 4/13/05 1012 0.5 1.4 0.00 +/- 0.04 3.88 0.44 0.05 +0.04
-0.02 +0.09 0.10 + 0.15 0.03 +/- 0.05 94 3/16/05 0829 0.2 + 1.4 0.01 + 0.02
-0.03 + 0.22 0.01 + 0.03 0.01 +/- 0.04 0.05 +/- 0.07 0.07 +/- 0.04 95 2/1/05 1030 0.7 +/- 1.4 0.01 + 0.02 0.01 + 0.24
-0.01 +/- 0.01 0.03 + 0.03
-0.06 + 0.06 0.02 + 0.03 96 1/11/05 1545
-0.7 1.4 0.01 +/- 0.01
-0.23 +0.23 0.00 0.01 0.01 + 0.02 0.00 0.05 0.01 +/- 0.02 97 1/11/05 1545
-0.1 +/- 1.4 0.02 +/- 0.02
-0.16 + 0.21 0.00 + 0.01 0.00 + 0.03
-0.03 + 0.07 0.01 + 0.02 98 6/8/05 1017
-1.4 1.4 0.02 + 0.03
-0.26 0.21 0.14 0.03
-0.01 +0.05 0.10 0.09 0.10 + 0.07 99 6/22/05 0955 0.6 +/- 1.5 0.19 +/- 0.05
-0.10 + 0.23 0.84 + 0.06
-0.03 + 0.05 0.01 + 0.09 0.04 +/- 0.06 100 6/20/05 1430 0.5 +/- 2.2 0.02 + 0.03 0.08 + 0.24 0.11 + 0.03
-0.02 + 0.04
-0.01 + 0.10 0.02 +/- 0.05 101 6/21/05 0900 0.0 1.4 6.87 + 0.28 0.19 0.25 33.0 +1.2 0.00 0.12
-0.16 + 0.16 0.00 + 0.09 102 7/21/05 0811
-0.1 1.4 0.03 + 0.02
-0.11 0.22 0.25 0.03
-0.02 +0.04
-0.01 + 0.10 0.02 + 0.03 103 7/21/05 0815
-0.9 +/- 1.5 0.19 + 0.05
-0.01 + 0.23 0.79 + 0.06
-0.02 + 0.05
-0.03 +/- 0.10 0.03 + 0.05 000 0v 0-0 Ut R
C>
C>
Ct
4 TABLE 1 (continued) 00 0
0 0-0.
0 0
01 B
CC CD RADIONUCLIDE CONCENTRATIONS IN SOIL AND MISCELLANEOUS SAMPLES SUBMITTED TO ESSAP BY THE NRC CONNECTICUT YANKEE HADDAM, CONNECTICUT Sample Collecteda Radionuclide Concentrations (pCi/g)
Identification Date lj Time H-3 l
Co-60 Sr-90 Cs-137 Eu-152 Eu-154 Eu-155 Miscellaneous Samples 1
5/9/05 1515 3.4 + 1.6 0.00 +0.04
-0.04 + 0.22
-0.03 + 0.04 0.04 +/- 0.06
-0.01 + 0.15 0.03 +/- 0.05 2
5/9/05 1515 6.8 +/- 1.7
-0.01 + 0.04
-0.15 +/- 0.22
-0.01 +/- 0.03 0.04 + 0.07
-0.16 + 0.14 0.02 +/- 0.06 3
5/9/05 1435 10.4 1.9 0.04 + 0.04 0.29 +/- 0.25 0.00 +/- 0.04
-0.02 +/- 0.08 0.07 + 0.20
-0.02 + 0.06 4
6/9/05 1005 0.0 +/- 1.5 0.03 + 0.05 0.09 + 0.23 0.08 +/- 0.06
-0.08 +/- 0.12
-0.09 + 0.23 0.13 + 0.11 5
6/9/05 1155 0.7 + 1.5 0.03-+ 0.05
-0.07 + 0.23 0.01 +/- 0.03
-0.04 +/- 0.06 0.01 + 0.14
-0.02 +/- 0.06 6
6/9/05 1400
-0.5 + 1.5 0.01 +/- 0.03
-0.11 +/- 0.24 0.02 + 0.03
-0.01 +/- 0.05
-0.09 + 0.10 0.01 + 0.04 7
7/11/05 1005
-0.9 + 1.4 0.00 + 0.04
-0.04 + 0.21 0.07 + 0.06 0.00 + 0.07
-0.01 + 0.16
-0.02 + 0.04 8
7/11/05 1100
-0.5 + 1.5 0.00 + 0.03
-0.17 +/- 0.22 0.01 + 0.03 0.05 +/- 0.06
-0.02 +/- 0.13 0.03 + 0.04 9
7/11/05 1100
-0.4 + 1.5 0.05 + 0.04
-0.16 + 0.19 0.01 + 0.02
-0.03 0.05 0.02 0.12 0.01 0.04 10 4/7/05 1350 3.1 + 1.5 0.00 + 0.04
-0.20 + 0.21
-0.04 + 0.04 0.01 0.08 0.11 0.17
-0.02 0.06 11 4/7/05 1110 4.2 + 1.6
-0.07 + 0.07
-0.01 + 0.23
-0.03 + 0.07
-0.01 + 0.15
-0.27 + 0.40 0.05 + 0.11 aSample collection date and time provided by CYAPCO.
bUncertainties represent the 95% confidence level, based on total propagated uncertainties.
cZero values due to rounding.
0 00 0
0 t-,j 0
o a
a C
0.
0 c
tA