ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT HADDAM NECK STATION RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM JANUARY 1, 2003 - DECEMBER 31, 2003 DOCKET NO. 50-213 LICENSE NO. DPR-61 AREVA DOC. # 47-5042205-00 CONNECTICUT YANKEE ATOMIC POWER COMPANY Haddam, Connecticut
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 ii TABLE OF CONTENTS 1.0 EXECUTIVE
SUMMARY
....................................................................................................................................1
2.0 INTRODUCTION
..................................................................................................................................................2 2.1 GENERAL PLANT SITE INFORMATION.....................................................................................................................2 2.2 PROGRAM DESIGN.................................................................................................................................................2 2.3 MONITORING ZONES..............................................................................................................................................3 2.4 PATHWAYS MONITORED........................................................................................................................................3
2.5 DESCRIPTION
S OF MONITORING PATHWAYS..........................................................................................................3 2.5.1 Air Sampling.................................................................................................................................................3 2.5.2 River Water Sampling...................................................................................................................................4 2.5.3 Well Water Sampling....................................................................................................................................4 2.5.4 Sediment Sampling........................................................................................................................................4 2.5.5 Milk Sampling...............................................................................................................................................4 2.5.6 Fish Sampling...............................................................................................................................................4 2.5.7 Shellfish Sampling........................................................................................................................................4 2.5.8 Food Product Sampling................................................................................................................................4 2.5.9 Broad Leaf Vegetation..................................................................................................................................4 2.5.10 ISFSI Sediment and Water Sampling............................................................................................................4 2.5.11 TLD Monitoring............................................................................................................................................6 2.5.12 ISFSI TLD Monitoring..................................................................................................................................6 2.6 SAMPLES COLLECTED DURING 2003...................................................................................................................16 3.0 RADIOLOGICAL DATA
SUMMARY
TABLES.............................................................................................17 4.0 ANALYSIS OF ENVIRONMENTAL RESULTS..............................................................................................32 4.1 SAMPLING PROGRAM DEVIATIONS......................................................................................................................32 4.2 COMPARISON OF ACHIEVED LLD WITH REQUIREMENTS.....................................................................................33 4.3 RESULTS COMPARED AGAINST REPORTING LEVELS............................................................................................33 4.4 DATA ANALYSIS BY MEDIA TYPE........................................................................................................................33 4.4.1 Air Particulate Gross Beta Radioactivity...................................................................................................34 4.4.2 River Water.................................................................................................................................................35 4.4.3 Well Water..................................................................................................................................................35 4.4.4 Bottom Sediment.........................................................................................................................................37 4.4.5 Fruits and Vegetables.................................................................................................................................38 4.4.6 Broad Leaf Vegetation................................................................................................................................38 4.4.7 Shellfish......................................................................................................................................................38 4.4.8 Fish.............................................................................................................................................................38 4.4.9 Gamma Exposure Rate...............................................................................................................................38 4.4.10 ISFSI Gamma Exposure Rate.....................................................................................................................41 5.0 OFF-SITE DOSE EQUIVALENT COMMITMENTS......................................................................................43
6.0 REFERENCES
......................................................................................................................................................44 Appendix A - Land Use Census for 2003.....A-1 Appendix B - Quality Assurance Program...B-1 Appendix C - Summary of 2003 REMP Data...C-1
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 1
1.0 EXECUTIVE
SUMMARY
The radiological environmental monitoring program for the Haddam Neck Station was continued for the period January through December 2003, in compliance with the Technical Specifications and the Radiological Effluent Monitoring and Off-Site Dose Calculation Manual (REMODCM). This annual report was prepared for the Connecticut Yankee Atomic Power Company (CYAPCO) by Areva, formerly known as Framatome ANP. Sample collection and preparation were performed by Normandeau Associates. Laboratory analyses were performed by Framatome ANP Environmental Laboratory (FANPEL), a subsidiary of Areva.
Thermoluminescent dosimeters (TLDs) were used to measure direct gamma exposure in the vicinity of the station and as far away as 12.5 miles. Radiochemical and radiological counting analyses of samples were performed to detect the presence of any station related radioactivity. In the second quarter of 2003, additional sampling locations associated with the placement onsite of an Independent Spent Fuel Storage Installation (ISFSI) were selected for the purpose of collecting baseline background information prior to the transfer of spent fuel from the main plant to the ISFSI.
Samples included air particulates collected on filters, broad leaf vegetation, fruits/vegetables, well water, river water, ISFSI water, bottom sediment, ISFSI bottom sediment, shellfish, and fish. In evaluating the results of these analyses it is necessary to consider the variability of natural and man-made sources of radioactivity, distribution in the environment and uptake in environmental media. This variability is dependent on many factors including station release rates, past spatial variability of radioactive fallout from nuclear weapons tests and on-going redistribution of fallout, contribution from cosmogenic radioactivity, ground water dynamics, soil characteristics, farming practices, and feed type. Any one of these factors could cause significant variations in measured levels of radioactivity. Therefore, these factors need to be considered in order to properly explain any variations in radiation detected and to distinguish between natural and station related radioactivity.
Haddam Neck was permanently shutdown in 1996. Current activities at the Haddam Neck station are focused on fuel storage, site decontamination and facility decommissioning. Even though the station is no longer generating power, decommissioning activities include the processing and discharge of liquids containing radioactivity. Monitoring continues for any release of airborne radioactivity. The levels of radioactivity released post-operation are significantly lower than released during plant operation. The radiological monitoring of the environment through this program will continue to assure the health and safety of the public and workers are maintained at all times.
The predominant radioactivity detected by the monitoring program was that from outside sources, such as fallout from nuclear weapons tests and naturally occurring radionuclides. Station related Cobolt-60 was observed in one bottom sediment sample. However, the identification occurred in the area of plant discharge, representing a pathway that is not involved with significant exposure to the public.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 2
2.0 INTRODUCTION
2.1 General Plant Site Information The Connecticut Yankee plant is located in the town of Haddam, Middlesex County, Connecticut, at a point 22 miles south-southeast of Hartford, Connecticut; 25 miles northeast of New Haven, Connecticut; and 16 miles north of Long Island Sound. The site consists of approximately 525 acres and is situated on the east bank of the Connecticut River at an area known as Haddem Neck. The elevation of the site property varies from 10 to 300 feet above sea level, with the area occupied by plant facilities ranging between 10 and 21 feet above sea level. The minimum distance from the reactor containment to the site boundary is approximately 1700 feet.
The plant was designed as a single unit pressurized water reactor which sustained its initial chain reaction in July 1967, with commercial operation beginning in January 1968 and a gross power output of 590 Mw (e). After 28 years of operation, the CY Board of Directors voted in 1996 to permanently close and decommission the power plant. Following two years of planning and preparation, actual decommissioning began in 1998 and was underway during 2003 for which this radiological environmental monitoring report covers.
2.2 Program Design The Radiological Environmental Monitoring Program for the Haddam Neck Station was designed with specific objectives.
To provide an early indication of the appearance or accumulation of any radioactive material in the environment cased by Haddam Neck Station activities.
To provide assurance to regulatory agencies and the public that the environmental impact for Haddam Neck Station is known and within anticipated limits.
To verify the adequacy and proper functioning of station effluent controls and monitoring systems.
These objectives continue to be in force throughout the decommissioning activities at the Haddam Neck Station site. Due to the shutdown status of the plant and the relatively low quantities of radioactive material now on the site, some of the objectives have shifted in degree of importance from the past.
The radiological environmental monitoring program continued without modification following the plant shutdown in 1996. The program scope was reduced in 2000 and implemented beginning in 2001 primarily to reflect the absence of a source of radionuclide production and to account for the long decay period, since shutdown, for the individual short half-life radionuclides in the various pathways. The onsite radionuclide inventory continues to decrease yearly with the shipments to off-site facilities and radioactive decay.
The program was developed to meet the intent of the NRC Regulatory Guide 4.1, Programs for Monitoring Radioactivity in the Environs of Nuclear Power Plants; NRC Regulatory Guide 4.8, Environmental Technical Specifications for Nuclear Power Plants; the NRC Branch Technical Position of November 1979, An Acceptable Radiological Environmental Monitoring Program; and NRC NUREG-0472, Radiological Effluent Technical Specifications for PWR's.
The environmental TLD program was developed using NRC Regulatory Guide 4.13, Performance, Testing and Procedural Specifications for Thermoluminescence Dosimetry: Environmental Applications. The quality assurance
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 3
program was designed using the guidance given in NRC Regulatory Guide 4.15, Quality Assurance for Radiological Monitoring Programs (Normal Operations) - Effluent Streams and the Environment.
The sampling requirements of the REMODCM are given in Table E-1 of the ODCM and Table 2.1 of this report. The identification of the required sampling locations is given in Appendix G of the ODCM and Table 2.2 of this report. The monitoring locations are shown graphically in Figures 2.1 and 2.2.
2.3 Monitoring Zones The REMP is designed to allow comparison of levels of radioactivity in samples from the area potentially influenced by the plant to levels found in areas not influenced by the plant. The first area monitoring locations are designated as indicators and the second area monitoring locations are designated as controls. The distinction between the two areas, for a particular pathway, is based on relative direction from the plant, river flow, and distance. Analysis of survey data from the two areas is used to differentiate between radiation due to plant activities and other sources such as atmospheric nuclear weapons test fallout or seasonal variations in the natural background.
2.4 Pathways Monitored Four pathway categories; airborne, waterborne, ingestion, and direct radiation are monitored by the REMP. Each of these categories is monitored by the collection of one or more sample types listed and described below.
Airborne Pathway:
Air Particulate Sampling Waterborne Pathway:
River Water Well Water Sediment Sampling ISFSI Sediment and Water Sampling Ingestion Pathway:
Fruits and Vegetable Sampling Fish and Shellfish Sampling Broadleaf Vegetation Milk Sampling (when required and if available)
Direct Radiation:
TLD Monitoring ISFSI TLD Monitoring 2.5 Descriptions of Monitoring Pathways Sample types and frequency of analysis are given in Table 2.1. The sample locations are listed in Table 2.2 and shown in Figures 2.1 and Figure 2.2. The program as described in this report includes both required samples as specified in the REMODCM and any extra samples.
2.5.1 Air Sampling Continuous air samplers are installed at five locations as required by the REMODCM. The sampling pumps at these locations operate continuously at a flow rate of approximately one cubic foot per minute. Airborne particulates are collected by passing air through a 47-mm glass-fiber filter. A dry gas meter is incorporated into the sampling stream to measure the total volume of air sampled in a given interval. The filters are collected biweekly, and to allow for the decay of radon daughter products, they are held at least 100 hours0.00116 days <br />0.0278 hours <br />1.653439e-4 weeks <br />3.805e-5 months <br /> before being analyzed for gross-beta radioactivity (indicated as GR-B in the data tables). The biweekly filters are combined by location at the FANPEL for a quarterly gamma spectroscopy analysis.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 4
2.5.2 River Water Sampling River water samples are collected from two sampling locations, an indicator and control station. An automatic composite sampler is located at the indicator sampling station (28-I) collecting an equal volume of water every hour. A grab sample is collected once every two weeks at the control sampling station, 30-C. Approval to relocate station 30-C approximately one mile upriver was granted in April and the station is renamed 30-A-C for samples collected from May 2003 on. All quarterly samples receive a gamma isotopic and tritium analysis 2.5.3 Well Water Sampling Well water samples are collected quarterly from one onsite well and one off-site well. Gamma isotopic and tritium analyses are performed on each.
2.5.4 Sediment Sampling Shoreline sediment samples are collected semiannually from three locations, one near the plant discharge, one downstream and one control station, upstream from the plant. A grab sample is taken semiannually from each location; they are dried at the FANPEL and analyzed for gamma-emitting radionuclides.
2.5.5 Milk Sampling Milk sampling is no longer a requirement of the REMODCM unless indicated by the annual Land Use Census and dose calculations.
2.5.6 Fish Sampling Fish samples are collected semiannually from three river locations, two indicator stations from the vicinity of the intake and discharge and one control station north of the plant. The species typically collected are bullheads, perch and /or catfish. The edible portions of the fish are analyzed for gamma-emitting radionuclides.
2.5.7 Shellfish Sampling Shellfish samples are collected semiannually from two river locations. The shellfish is shucked and the muscle portions are analyzed by gamma isotopic analysis.
2.5.8 Food Product Sampling Food products are collected from two locations near the beginning of the growing season and at the end of the season. The samples are either tuberous vegetables, aboveground vegetables, or fruit. The sampling requirement is that one sample is collected from a location within 10 miles of the plant and the other from a location beyond 10 miles. The samples are analyzed by gamma isotopic analysis.
2.5.9 Broad Leaf Vegetation Leafy vegetation is collected from three locations, one on-site, one at the site boundary and one at a control location. During 2003, broad leaf vegetation was also collected from an extra sampling location, 41-X, that is not part of the required REMP.
These samples are collected monthly during the growing season from April to December.
2.5.10 ISFSI Sediment and Water Sampling In the second quarter of 2003, seven additional sampling locations (five indicator locations and two extra locations) associated with the placement on-site of an Independent Spent Fuel Storage Installation (ISFSI) were selected for the purpose of collecting baseline background information prior to the transfer of spent fuel from the main plant to the ISFSI. These new locations are specific to the ISFSI and are beyond the standard REMP that has been in operation over the life of the power plants license. ISFSI sediment samples are collected quarterly from two locations, one at nearby wetland location and one
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 5
near the ISFSI pad. A grab sample is taken quarterly from each location; they are dried at the FANPEL and analyzed for gamma-emitting radionuclides. Gamma isotopic and tritium analysis is performed on all water samples.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 6
2.5.11 TLD Monitoring Direct gamma radiation exposure is continuously monitored with the use of Panasonic UD-801AS1 thermoluminescent dosimeters (TLDs). TLDs are posted at fourteen REMODCM required locations and at nine extra locations. The extra locations are mostly within the site boundary and are not part of the REMP. Their function is to monitor the potential impact of on-site activities such as the movement or storage of decommissioned components on site boundary exposure rates.
2.5.12 ISFSI TLD Monitoring In the second quarter of 2003, seven additional sampling locations (five indicator locations and two extra locations) associated with the placement on-site of an Independent Spent Fuel Storage Installation (ISFSI) were selected for the purpose of collecting baseline background information prior to the transfer of spent fuel from the main plant to the ISFSI. These new locations are specific to the ISFSI and are beyond the standard REMP that has been in operation over the life of the power plants license. New quarterly TLD locations were located in the area surrounding the facility at distances that approximated the site boundary to support future determinations that direct and scatter dose from ISFSI operations remain in compliance with offsite dose limits to the public.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 7
Table 2.1-Required Sampling Frequency & Type of Analysis (REMODCM Table E-1)
Exposure Pathway and/or Sample Number of Locations Sampling & Collection Frequency Type of Analysis 1a. Gamma Exposure -
Environmental TLD 14 Quarterly Gamma Dose - Quarterly 1b. Gamma Exposure -
Quarterly Gamma Dose - Quarterly 2.
Airborne Particulate 5
Continuous sampler -
biweekly filter change Gross Beta - Biweekly Gamma Isotopic - Quarterly on composite (by location), and on individual filter if gross beta is greater than 10 times the mean of the biweekly control stations gross beta results 3a. Vegetation - Fruits and Vegetables 2
One sample near middle &
one near end of growing season Gamma Isotopic on each sample 3b. Vegetation - Broad Leaf Vegetation 3
Monthly during growing season (April - December)
Gamma Isotopic on each sample 4.
Milk 4
Monthly, if required Gamma Isotopic on each sample - Monthly Sr-89 and Sr Quarterly 5.
Well Water 2
Quarterly Gamma Isotopic and Tritium on each composite 6.
Bottom Sediment 3
Semiannually Gamma Isotopic 7.
ISFSI Sediment 2
Quarterly Gamma Isotopic 8.
River Water 2
Quarterly Sample - Indicator is continuous composite; Background is composite of grab samples collected biweekly Gamma Isotopic and Tritium - Quarterly 9.
ISFSI Water 2
Quarterly Gamma Isotopic and Tritium
- 10. Fish (edible portion) -
bullheads and, when available, perch or other edible fish 3
Semiannual Gamma Isotopic - Semiannual
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 8
- 11. Shellfish 2
Semiannual Gamma Isotopic - Semiannual
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 9
Table 2.2 - Environmental Monitoring Program Sampling Types and Locations Exposure Pathway (Sample Type Designation)
Location Number1 Location Name Distance From Release Point2 (miles)
Direction From ReleasePoint2 Airborne
- a. Filter (AP) 5-I On-site-Injun Hollow Rd.
0.4 NW 6-I On-site-Substation 0.5 NE 7-I Haddam 1.8 SE 9-I Higganum 4.3 WNW 13-C North Madison 12.5 SW
- b. Vegetation (TV) 6-I On-site-Substation 0.5 NE 18-I Site Boundary 0.4 NW 13-C North Madison 12.5 SW Waterborne
- b. Well Water (WW) 15-I On-site Wells 0.5 ESE 16-C Well-State Highway Dept. E.
Haddam 2.8 SE
- c. Bottom Sediment (SE) 28-I CT River-E. Haddam Bridge 1.8 SE 29-I Vicinity of Discharge Within 0.3 Miles 30-C CT River - Middletown 9.0 NW ISFSI
- a. Bottom Sediment (IF) 57-IF Dibble Creek Sediment Sample 0.1 SE 58-IF ISFSI Pad Enclosure Soil Sample 0.0 N/A
- b. ISFSI Water (WG) 57-IF Dibble Creek Sediment Sample 0.1 SE 58-IF ISFSI Drain Pipe Outflow 0.0 N/A Ingestion
- a. Fruits & Vegetables (TF) 17-C Beyond 10 Miles Beyond 10 miles SW 25-I Within 10 Miles Within 10 miles NW
- b. Fish (FH) 26-I CT River-Near Intake 1.0 WNW 29-I Vicinity of Discharge Within 0.3 miles 30-C CT River - Middletown 7.6 NW
- c. Shellfish (SF) 27-C CT River-Higganum Light 4.0 WNW 31-I Mouth of Salmon River 0.8 ESE
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 10 1
I=Indicator C=Control IF=ISFSI 2
The release points are the stack for terrestrial locations and the end of the discharge canal for aquatic locations
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 11 Table 2.2 - Environmental Monitoring Program Sampling Types and Locations (continued)
Exposure Pathway (Sample Type Designation)
Location Number1 Location Name Distance From Release Point2 (miles)
Direction From Release Point2 Direct Radiation TLD 1-I On-site - Mouth of Discharge Canal 1.1 ESE 2-I Haddam-Park Rd.
0.8 S
3-I Haddam-Jail Hill Rd.
0.8 WSW 4-I Haddam-Ranger Rd.
1.8 SW 5-I On-site-Injun Hollow Rd.
0.4 NW 6-I On-site-Substation 0.5 NE 7-I Haddam 1.8 SE 8-I East Haddam 3.1 ESE 9-I Higganum 4.3 WNW 10-I Hurd Park Rd.
2.8 NNW 11-C Middletown 9.0 NW 12-C Deep River 7.1 SSE 13-C North Madison 12.5 SW 14-C Colchester 10.5 NE 40-X Near Intake Structure 0.1 SSW 41-X Picnic Area 0.3 WNW 42-X Environmental Trail 0.1 NW 43-X Moodus - Rts 149 & 151 2.5 ENE 44-X Shailerville, Horton Rd.
1.0 SE 45-X Old Waste Gas Sphere Fence 0.1 E
46-X Discharge Canal Fence 0.2 SE 47-X Visitor Info Center 0.1 WNW 48-X Onsite Met Tower Shack 0.4 WSW 52-IF Schmidt Cemetery Onsite 0.5 NNE 53-IF ISFSI Haul Route Onsite 0.2 SSW 54-IF Rt. 149 Salmon River 1.0 ESE 55-IF HV Tower NW of Pad 0.4 NW 56-IF Burrow Pit On-Site 0.2 E
1 I=Indicator C=Control X=Extra (not part of REMP) IF=ISFSI Indicator 2
The release points are the stack for terrestrial locations and the end of the discharge canal for aquatic locations
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 12 Table 2.3 - Environmental Lower Limit of Detection (LLD) Sensitivity Requirements (REMODCM Table E-3)
Analysis Water (pCi/l)
Airborne Particulate or Gas (pCi/m3)
Fish (pCi/kg wet)
Milk (pCi/l)
Food Products (pCi/kg/wet)
Sediment (pCi/kg dry)
Gross Beta 0.01 H-3 2000 Mn-54 15 130 Co-60 15 130 150 Zn-65 30 260 Cs-134 15 0.05 130 15 60 150 Cs-137 18 0.06 150 18 80 180 Table 2.4 - Reporting Levels for Radioactivity Concentrations in Environmental Samples (REMODCM Table E-2)
Analysis Water (pCi/l)
Airborne Particulates or Gases (pCi/m3)
Fish (pCi/kg wet)
Milk (pCi/l)
Vegetables (pCi/kg,wet)
Shellfish (pCi/kg,wet)
H-3 20000 Mn-54 1000 30000 140000 Co-60 300 10000 50000 Zn-65 300 20000 80000 Cs-134 30 10 1000 60 1000 5000
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 13 Cs-137 50 20 2000 70 2000 8000
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 14 Figure 2.1 - Haddam Neck Sampling Locations
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 15 Figure 2.2 - Haddam Neck SamplingLocations
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 16 2.6 Samples Collected During 2003 The following table summarizes the number of samples of each type collected during the 2003 reporting period:
Sample Type Number of Samples Analyzed in 2003 Number of Analyses by Station Type Indicator Control Extra Gamma Exposure environmental TLD 92 40 16 36 ISFSI TLD 21 15 6
Air Particulate 124 99 25 Fish Bone 2
2 Fish Flesh 2
2 Fish 18 12 6
Bottom Sediment 6
4 2
Shellfish 6
3 3
ISFSI Sediment 4
4 Fruit & Vegetables 4
2 2
Broad Leaf Vegetation 24 18 6
ISFSI Water 2
2 River Water 8
4 4
Well Water 8
4 4
Total All Types 321 211 68 42
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 17 3.0 RADIOLOGICAL DATA
SUMMARY
TABLES This section summarizes the analytical results of the environmental samples that were collected during 2003. These results, shown in Table 3.1, are presented in a format similar to that prescribed in the NRC's Radiological Assessment Branch Technical Position on Environmental Monitoring (Reference 1). The results are ordered by sample media type and then by radionuclide for the pathways described in Section 2.3. The units for each media type are also given. Table 3.2 provides the same information for TLD direct radiation measurements.
The left-most column contains the radionuclide of interest, the total number of analyses for that radionuclide in 2003, and the number of measurements which exceeded the Reporting Levels found in Table 2.5. The latter are classified as "Non-routine" measurements. The second column lists the required Lower Limit of Detection (LLD) for those radionuclides, which have detection capability requirements specified in Table 2.4. The absence of a value in this column indicates that no LLD is specified in the REMODCM for that radionuclide in that media. The target LLD for any analysis performed by the FANPEL is typically 30-40 percent of the most restrictive required LLD.
For each media type and radionuclide, the remaining three columns summarize the data for the following categories of monitoring locations: (1) the Indicator stations, which are within the range of influence of the plant and which could conceivably be affected by plant activities; (2) the station which had the highest mean concentration during 2003, and (3) the Control stations, which are beyond the influence of the plant. Direct radiation monitoring stations (using TLDs) are grouped into Indicator and Control stations.
In each of these columns, for each radionuclide, the following are given:
The mean value of all concentrations including negative values and values that are not considered detectable.
The lowest and highest concentration.
The number of detectable measurements divided by the total number of measurements.
A sample is considered to yield a "detectable measurement" when the concentration exceeds three times its associated standard deviation. The standard deviation on each measurement represents only the random uncertainty associated with the radioactive decay process (counting statistics), and not the propagation of all possible uncertainties in the analytical procedure.
The radionuclides reported in this section represent those that: 1) had a Reporting Level listed in Table E-2 of the REMODCM or, a LLD requirement in Table E-3 of the REMODCM or 2) had a positive measurement of radioactivity, whether it was naturally-occurring or man-made; or 3) were of specific interest for any other reason. The radionuclides that are routinely analyzed and reported by the FANPEL in a gamma spectroscopy analysis are: Ac/Th-228, Ag-108m, Ag-110m, Ba-140, Be-7, Ce-141, Ce-144, Co-57, Co-58, Co-60, Cr-51, Cs-134, Cs-137, Fe-59, I-131, K-40, La-140, Mn-54, Nb-95, Ru-103, Ru-106, Sb-124, Sb-125, Se-75, Zn-65 and Zr-95. In no instance did a radionuclide that is not shown in Table 3.1 appear as a "detectable measurement" during 2003.
Data from direct radiation measurements made by TLDs are provided in Table 3.2 in a format essentially the same as above.
The complete listing of quarterly TLD data is provided in Table 3.3.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 18 Table 3.1 Radiological Environmental Program Summary Connecticut Yankee Nuclear Power Co., Haddam Neck Station (January - December 2003)
MEDIUM: Air Particulates (AP) UNITS: pCi/cubic meter Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Station Mean Mean (No. Analyses)
Required Range Range Range Non-Routine* LLD No. Detected** No. Detected** No. Detected**
GR-B (124) 0.01 2.0E -2 13 2.0E -2 2.0E -2 (0)
( 8.0 - 31.7)E -3
( 9.4 - 36.1)E -3
( 9.4 - 36.1)E -3 (99/ 99)
(25/ 25)
(25/ 25)
Be-7 (20) 8.5E -2 06 9.5E -2 7.7E -2 (0)
( 5.2 - 11.9)E -2
( 7.4 - 11.9)E -2
( 5.8 - 11.7)E -2 (14/ 16)
(4/ 4)
(3/ 4)
Co-58 (20) 1.2E -4 06 4.7E -4
-9.5E -5 (0)
( -1.3 - 2.8)E -3
( -2.1 - 15.0)E -4
( -8.8 - 4.8)E -4 (0/ 16)
(0/ 4)
(0/ 4)
Co-60 (20) 9.1E -5 06 7.2E -4 3.3E -4 (0)
( -1.7 - 1.5)E -3
( -5.7 - 15.1)E -4
( -3.6 - 9.4)E -4 (0/ 16)
(0/ 4)
(0/ 4)
Cs-134 (20) 0.05
-7.6E -5 06 2.9E -4
-2.1E -4 (0)
( -1.5 - 0.8)E -3
( -4.0 - 6.1)E -4
( -1.2 - 0.6)E -3 (0/ 16)
(0/ 4)
(0/ 4)
Cs-137 (20) 0.06
-1.8E -4 13 3.3E -4 3.3E -4 (0)
( -2.2 - 0.7)E -3
( -3.9 - 7.5)E -4
( -3.9 - 7.5)E -4 (0/ 16)
(0/ 4)
(0/ 4)
- Non-Routine refers to radionuclides that exceeded the Reporting Levels in ODCM Table E-2
- The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 19 Table 3.1 Radiological Environmental Program Summary Connecticut Yankee Nuclear Power Co., Haddam Neck Station (January - December 2003)
MEDIUM: Fish Bone (FB) UNITS: pCi/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Station Mean Mean (No. Analyses)
Required Range Range Range Non-Routine* LLD No. Detected** No. Detected** No. Detected**
Sr-89 (2) 1.4E 1 WI 1.5E 2 NO DATA (0)
( -1.2 - 1.5)E 2 (0/ 2)
(0/ 1)
Sr-90 (2)
-2.5E 1 WI
-2.0E 1 NO DATA (0)
( -2.9 - -2.0)E 1 (0/ 2)
(0/ 1)
- Non-Routine refers to radionuclides that exceeded the Reporting Levels in ODCM Table E-2
- The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 20 Table 3.1 Radiological Environmental Program Summary Connecticut Yankee Nuclear Power Co., Haddam Neck Station (January - December 2003)
MEDIUM: Fish Flesh (FF) UNITS: pCi/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Station Mean Mean (No. Analyses)
Required Range Range Range Non-Routine* LLD No. Detected** No. Detected** No. Detected**
K-40 (2) 2.6E 3 HA 2.8E 3 NO DATA (0)
( 2.5 - 2.8)E 3 (2/ 2)
(1/ 1)
Mn-54 (2) 130 5.5E -1 HA 3.4E 0 NO DATA (0)
( -2.3 - 3.4)E 0 (0/ 2)
(0/ 1)
Co-58 (2)
-5.0E -2 HA 1.2E 0 NO DATA (0)
( -1.3 - 1.2)E 0 (0/ 2)
(0/ 1)
Fe-59 (2)
-4.0E 0 HA 9.0E 0 NO DATA (0)
( -1.7 - 0.9)E 1 (0/ 2)
(0/ 1)
Co-60 (2) 130
-2.8E 0 WI 1.5E 0 NO DATA (0)
( -7.0 - 1.5)E 0 (0/ 2)
(0/ 1)
Zn-65 (2) 260 5.3E 0 WI 2.3E 1 NO DATA (0)
( -1.2 - 2.3)E 1 (0/ 2)
(0/ 1)
Cs-134 (2) 130 2.5E 0 HA 3.2E 0 NO DATA (0)
( 1.9 - 3.2)E 0 (0/ 2)
(0/ 1)
Cs-137 (2) 150 9.3E 0 HA 1.4E 1 NO DATA (0)
( 4.8 - 13.8)E 0 (1/ 2)
(1/ 1)
- Non-Routine refers to radionuclides that exceeded the Reporting Levels in ODCM Table E-2
- The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 21 Table 3.1 Radiological Environmental Program Summary Connecticut Yankee Nuclear Power Co., Haddam Neck Station (January - December 2003)
MEDIUM: Fish (FH) UNITS: pCi/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Station Mean Mean (No. Analyses)
Required Range Range Range Non-Routine* LLD No. Detected** No. Detected** No. Detected**
K-40 (18) 2.2E 3 29 2.4E 3 2.3E 3 (0)
( 9.2 - 34.3)E 2
( 1.8 - 3.4)E 3
( 1.4 - 3.0)E 3 (12/ 12)
(6/ 6)
(6/ 6)
Mn-54 (18) 130
-1.1E 0 26 2.4E 0
-7.0E -1 (0)
( -2.0 - 2.8)E 1
( -2.0 - 2.8)E 1
( -1.0 - 0.6)E 1 (0/ 12)
(0/ 6)
(0/ 6)
Co-58 (18) 4.6E 0 26 5.1E 0
-4.1E 0 (0)
( -2.3 - 2.4)E 1
( -2.3 - 2.4)E 1
( -1.4 - 1.0)E 1 (0/ 12)
(0/ 6)
(0/ 6)
Fe-59 (18) 1.3E 1 29 1.9E 1
-3.0E 0 (0)
( -3.4 - 6.6)E 1
( -3.4 - 6.6)E 1
( -5.9 - 4.2)E 1 (0/ 12)
(0/ 6)
(0/ 6)
Co-60 (18) 130
-5.2E 0 30
-1.7E 0
-1.7E 0 (0)
( -3.4 - 0.8)E 1
( -2.1 - 1.0)E 1
( -2.1 - 1.0)E 1 (0/ 12)
(0/ 6)
(0/ 6)
Zn-65 (18) 260
-9.3E 0 29
-5.7E 0
-6.3E 0 (0)
( -6.2 - 4.2)E 1
( -6.2 - 4.2)E 1
( -4.0 - 4.2)E 1 (0/ 12)
(0/ 6)
(0/ 6)
Cs-134 (18) 130 4.2E 0 29 7.4E 0 5.4E 0 (0)
( -1.5 - 2.3)E 1
( -1.4 - 2.3)E 1
( -7.0 - 17.0)E 0 (0/ 12)
(0/ 6)
(0/ 6)
Cs-137 (18) 150 1.2E 1 29 1.6E 1 5.9E 0 (0)
( -1.1 - 4.5)E 1
( -7.0 - 45.0)E 0
( -1.9 - 2.2)E 1 (1/ 12)
(1/ 6)
(0/ 6)
- Non-Routine refers to radionuclides that exceeded the Reporting Levels in ODCM Table E-2
- The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 22 Table 3.1 Radiological Environmental Program Summary Connecticut Yankee Nuclear Power Co., Haddam Neck Station (January - December 2003)
MEDIUM: Bottom Sediment (SE) UNITS: pCi/kg dry Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Station Mean Mean (No. Analyses)
Required Range Range Range Non-Routine* LLD No. Detected** No. Detected** No. Detected**
Be-7 (6) 2.0E 2 30 3.6E 2 3.6E 2 (0)
( 2.0 - 33.0)E 1
( 3.4 - 3.7)E 2
( 3.4 - 3.7)E 2 (0/ 4)
(0/ 2)
(0/ 2)
K-40 (6) 9.9E 3 30 1.6E 4 1.6E 4 (0)
( 9.4 - 10.7)E 3
( 1.4 - 1.7)E 4
( 1.4 - 1.7)E 4 (4/ 4)
(2/ 2)
(2/ 2)
Co-58 (6)
-1.2E 1 29
-5.0E -2
-9.5E 0 (0)
( -2.6 - 0.8)E 1
( -8.1 - 8.0)E 0
( -1.8 - -0.1)E 1 (0/ 4)
(0/ 2)
(0/ 2)
Co-60 (6) 150 8.5E 1 29 1.6E 2 1.1E 1 (0)
( 8.0 - 302.0)E 0
( 1.3 - 30.2)E 1
( 8.0 - 13.0)E 0 (1/ 4)
(1/ 2)
(0/ 2)
Cs-134 (6) 150
-7.5E 0 30 1.5E 0 1.5E 0 (0)
( -4.1 - 1.2)E 1
( -4.0 - 7.0)E 0
( -4.0 - 7.0)E 0 (0/ 4)
(0/ 2)
(0/ 2)
Cs-137 (6) 180 8.9E 1 30 1.6E 2 1.6E 2 (0)
( 2.9 - 15.5)E 1
( 1.3 - 1.9)E 2
( 1.3 - 1.9)E 2 (3/ 4)
(2/ 2)
(2/ 2)
Th-232 (6) 6.1E 2 30 1.1E 3 1.1E 3 (0)
( 4.0 - 8.3)E 2
( 9.6 - 11.9)E 2
( 9.6 - 11.9)E 2 (4/ 4)
(2/ 2)
(2/ 2)
- Non-Routine refers to radionuclides that exceeded the Reporting Levels in ODCM Table E-2
- The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 23 Table 3.1 Radiological Environmental Program Summary Connecticut Yankee Nuclear Power Co., Haddam Neck Station (January - December 2003)
MEDIUM: Shell Fish (SF) UNITS: pCi/kg wet Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Station Mean Mean (No. Analyses)
Required Range Range Range Non-Routine* LLD No. Detected** No. Detected** No. Detected**
K-40 (6) 4.7E 2 31 4.7E 2 3.8E 2 (0)
( -7.2 - 104.0)E 1
( -7.2 - 104.0)E 1
( 2.7 - 4.5)E 2 (1/ 3)
(1/ 3)
(1/ 3)
Mn-54 (6) 130
-3.2E 0 27 2.6E 0 2.6E 0 (0)
( -1.0 - 0.2)E 1
( 1.0 - 3.8)E 0
( 1.0 - 3.8)E 0 (0/ 3)
(0/ 3)
(0/ 3)
Co-58 (6) 8.7E 0 31 8.7E 0 4.0E 0 (0)
( 4.0 - 12.0)E 0
( 4.0 - 12.0)E 0
( 0.0 - 7.0)E 0 (0/ 3)
(0/ 3)
(0/ 3)
Fe-59 (6) 7.0E 0 31 7.0E 0
-1.0E 1 (0)
( -2.3 - 4.4)E 1
( -2.3 - 4.4)E 1
( -2.1 - -0.3)E 1 (0/ 3)
(0/ 3)
(0/ 3)
Co-60 (6) 130
-6.4E 0 27 1.1E 1 1.1E 1 (0)
( -1.1 - -0.2)E 1
( 5.0 - 22.0)E 0
( 5.0 - 22.0)E 0 (0/ 3)
(0/ 3)
(0/ 3)
Zn-65 (6) 260 1.0E 0 31 1.0E 0
-1.6E 1 (0)
( -7.9 - 11.4)E 1
( -7.9 - 11.4)E 1
( -5.9 - 0.6)E 1 (0/ 3)
(0/ 3)
(0/ 3)
Cs-134 (6) 130
-6.7E 0 27 5.2E 0 5.2E 0 (0)
( -2.2 - 0.2)E 1
( -8.3 - 20.0)E 0
( -8.3 - 20.0)E 0 (0/ 3)
(0/ 3)
(0/ 3)
Cs-137 (6) 150
-6.7E -2 31
-6.7E -2
-3.4E 0 (0)
( -8.0 - 14.8)E 0
( -8.0 - 14.8)E 0
( -9.0 - 0.9)E 0 (0/ 3)
(0/ 3)
(0/ 3)
- Non-Routine refers to radionuclides that exceeded the Reporting Levels in ODCM Table E-2
- The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 24 Table 3.1 Radiological Environmental Program Summary Connecticut Yankee Nuclear Power Co., Haddam Neck Station (January - December 2003)
MEDIUM: ISFSI Sediment (SI) UNITS: pCi/kg dry Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Station Mean Mean (No. Analyses)
Required Range Range Range Non-Routine* LLD No. Detected** No. Detected** No. Detected**
Be-7 (4) 5.8E 2 57 9.3E 2 NO DATA (0)
( 1.0 - 9.9)E 2
( 8.6 - 9.9)E 2 (3/ 4)
(2/ 2)
K-40 (4) 9.7E 3 58 1.1E 4 NO DATA (0)
( 8.2 - 10.9)E 3
( 1.1 - 1.1)E 4 (4/ 4)
(2/ 2)
Co-58 (4)
-1.1E 1 57
-9.2E 0 NO DATA (0)
( -2.3 - 0.3)E 1
( -2.1 - 0.3)E 1 (0/ 4)
(0/ 2)
Co-60 (4) 150 3.1E 0 57 4.8E 0 NO DATA (0)
( -6.4 - 16.0)E 0
( -6.4 - 16.0)E 0 (0/ 4)
(0/ 2)
Cs-134 (4) 150
-2.0E 1 58
-8.0E 0 NO DATA (0)
( -6.9 - 5.3)E 1
( -6.9 - 5.3)E 1 (0/ 4)
(0/ 2)
Cs-137 (4) 180 2.7E 2 57 4.2E 2 NO DATA (0)
( 1.2 - 5.1)E 2
( 3.3 - 5.1)E 2 (4/ 4)
(2/ 2)
Th-232 (4) 7.0E 2 58 9.3E 2 NO DATA (0)
( 4.6 - 10.0)E 2
( 8.5 - 10.0)E 2 (4/ 4)
(2/ 2)
- Non-Routine refers to radionuclides that exceeded the Reporting Levels in ODCM Table E-2
- The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 25 Table 3.1 Radiological Environmental Program Summary Connecticut Yankee Nuclear Power Co., Haddam Neck Station (January - December 2003)
MEDIUM: Fruits/Vegetables (TF) UNITS: pCi/kg Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Station Mean Mean (No. Analyses)
Required Range Range Range Non-Routine* LLD No. Detected** No. Detected** No. Detected**
K-40 (4) 1.7E 3 25 1.7E 3 1.6E 3 (0)
( 1.6 - 1.9)E 3
( 1.6 - 1.9)E 3
( 1.3 - 1.9)E 3 (2/ 2)
(2/ 2)
(2/ 2)
Co-58 (4)
-1.2E 1 17
-2.5E 0
-2.5E 0 (0)
( -2.0 - -0.4)E 1
( -1.3 - 0.8)E 1
( -1.3 - 0.8)E 1 (0/ 2)
(0/ 2)
(0/ 2)
Co-60 (4) 3.3E 0 25 3.3E 0
-1.9E 1 (0)
( 1.0 - 5.6)E 0
( 1.0 - 5.6)E 0
( -2.5 - -1.3)E 1 (0/ 2)
(0/ 2)
(0/ 2)
I-131 (4)
-1.1E 2 17 1.2E 1 1.2E 1 (0)
( -2.0 - -0.2)E 2
( -2.0 - 4.3)E 1
( -2.0 - 4.3)E 1 (0/ 2)
(0/ 2)
(0/ 2)
Cs-134 (4) 60 5.0E -1 17 1.0E 1 1.0E 1 (0)
( -7.0 - 8.0)E 0
( 9.0 - 11.0)E 0
( 9.0 - 11.0)E 0 (0/ 2)
(0/ 2)
(0/ 2)
Cs-137 (4) 80
-3.6E 0 17 1.3E 1 1.3E 1 (0)
( -1.1 - 0.4)E 1
( 6.4 - 18.7)E 0
( 6.4 - 18.7)E 0 (0/ 2)
(0/ 2)
(0/ 2)
- Non-Routine refers to radionuclides that exceeded the Reporting Levels in ODCM Table E-2
- The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 26 Table 3.1 Radiological Environmental Program Summary Connecticut Yankee Nuclear Power Co., Haddam Neck Station (January - December 2003)
MEDIUM: Broad Leaf Vegetation (TV) UNITS: pCi/kg wet Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Station Mean Mean (No. Analyses)
Required Range Range Range Non-Routine* LLD No. Detected** No. Detected** No. Detected**
K-40 (24) 2.9E 3 06 3.4E 3 2.2E 3 (0)
( 9.0 - 52.5)E 2
( 9.6 - 52.5)E 2
( 8.7 - 37.7)E 2 (18/ 18)
(6/ 6)
(6/ 6)
Co-58 (24)
-5.3E 0 13 4.6E 0 4.6E 0 (0)
( -3.1 - 1.2)E 1
( -2.3 - 3.7)E 1
( -2.3 - 3.7)E 1 (0/ 18)
(0/ 6)
(0/ 6)
Co-60 (24)
-4.9E 0 06 1.1E 0
-7.8E -1 (0)
( -2.5 - 2.5)E 1
( -8.0 - 25.0)E 0
( -1.9 - 1.9)E 1 (0/ 18)
(0/ 6)
(0/ 6)
I-131 (24) 2.4E 1 06 2.5E 1 1.3E 1 (0)
( -4.2 - 14.0)E 1
( -3.0 - 84.0)E 0
( -1.7 - 4.5)E 1 (0/ 18)
(0/ 6)
(0/ 6)
Cs-134 (24) 60 4.4E 0 06 6.8E 0
-1.8E 0 (0)
( -1.0 - 2.5)E 1
( -5.0 - 25.0)E 0
( -1.5 - 0.8)E 1 (0/ 18)
(0/ 6)
(0/ 6)
Cs-137 (24) 80 1.8E 1 13 3.7E 1 3.7E 1 (0)
( -1.3 - 9.9)E 1
( 9.0 - 85.0)E 0
( 9.0 - 85.0)E 0 (2/ 18)
(2/ 6)
(2/ 6)
- Non-Routine refers to radionuclides that exceeded the Reporting Levels in ODCM Table E-2
- The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 27 Table 3.1 Radiological Environmental Program Summary Connecticut Yankee Nuclear Power Co., Haddam Neck Station (January - December 2003)
MEDIUM: ISFSI Water (WG) UNITS: pCi/liter Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Station Mean Mean (No. Analyses)
Required Range Range Range Non-Routine* LLD No. Detected** No. Detected** No. Detected**
H-3 (2) 2000
-2.5E 1 57
-2.5E 1 NO DATA (0)
( -1.1 - 0.6)E 2
( -1.1 - 0.6)E 2 (0/ 2)
(0/ 2)
Mn-54 (2) 15
-6.5E -2 57
-6.5E -2 NO DATA (0)
( -7.3 - 6.0)E -1
( -7.3 - 6.0)E -1 (0/ 2)
(0/ 2)
Co-58 (2) 7.1E -1 57 7.1E -1 NO DATA (0)
( 4.0 - 10.2)E -1
( 4.0 - 10.2)E -1 (0/ 2)
(0/ 2)
Fe-59 (2)
-1.3E 0 57
-1.3E 0 NO DATA (0)
( -1.8 - -0.7)E 0
( -1.8 - -0.7)E 0 (0/ 2)
(0/ 2)
Co-60 (2) 15
-2.7E -1 57
-2.7E -1 NO DATA (0)
( -3.0 - -2.3)E -1
( -3.0 - -2.3)E -1 (0/ 2)
(0/ 2)
Zn-65 (2) 30 7.0E -1 57 7.0E -1 NO DATA (0)
( -6.4 - 7.8)E 0
( -6.4 - 7.8)E 0 (0/ 2)
(0/ 2)
Zr-95 (2) 3.0E -1 57 3.0E -1 NO DATA (0)
( -8.0 - 14.0)E -1
( -8.0 - 14.0)E -1 (0/ 2)
(0/ 2)
I-131 (2)
-2.5E 0 57
-2.5E 0 NO DATA (0)
( -3.6 - -1.4)E 0
( -3.6 - -1.4)E 0 (0/ 2)
(0/ 2)
Cs-134 (2) 15 1.5E 0 57 1.5E 0 NO DATA (0)
( 1.1 - 1.8)E 0
( 1.1 - 1.8)E 0 (0/ 2)
(0/ 2)
Cs-137 (2) 18
-6.8E -1 57
-6.8E -1 NO DATA (0)
( -1.1 - -0.3)E 0
( -1.1 - -0.3)E 0 (0/ 2)
(0/ 2)
Ba-140 (2) 1.5E 0 57 1.5E 0 NO DATA (0)
( 1.2 - 1.9)E 0
( 1.2 - 1.9)E 0 (0/ 2)
(0/ 2)
- Non-Routine refers to radionuclides that exceeded the Reporting Levels in ODCM Table E-2
- The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 28 Table 3.1 Radiological Environmental Program Summary Connecticut Yankee Nuclear Power Co., Haddam Neck Station (January - December 2003)
MEDIUM: River Water (WR) UNITS: pCi/liter Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Station Mean Mean (No. Analyses)
Required Range Range Range Non-Routine* LLD No. Detected** No. Detected** No. Detected**
H-3 (8) 2000
-1.3E 2 30
-9.0E 1
-9.0E 1 (0)
( -7.1 - 4.8)E 2
( -6.0 - 2.3)E 2
( -6.0 - 2.3)E 2 (0/ 4)
(0/ 4)
(0/ 4)
Mn-54 (8) 15
-4.2E -1 30 1.1E 0 1.1E 0 (0)
( -1.6 - 0.7)E 0
( -1.4 - 21.0)E -1
( -1.4 - 21.0)E -1 (0/ 4)
(0/ 4)
(0/ 4)
Co-58 (8)
-5.3E -1 28
-5.3E -1
-6.5E -1 (0)
( -2.5 - 0.5)E 0
( -2.5 - 0.5)E 0
( -1.5 - 0.4)E 0 (0/ 4)
(0/ 4)
(0/ 4)
Fe-59 (8) 1.1E 0 30 2.4E 0 2.4E 0 (0)
( -5.1 - 9.0)E 0
( -1.1 - 6.9)E 0
( -1.1 - 6.9)E 0 (0/ 4)
(0/ 4)
(0/ 4)
Co-60 (8) 15
-1.3E 0 30
-7.5E -1
-7.5E -1 (0)
( -3.1 - 0.0)E 0
( -3.3 - 1.2)E 0
( -3.3 - 1.2)E 0 (0/ 4)
(0/ 4)
(0/ 4)
Zn-65 (8) 30
-9.7E -1 28
-9.7E -1
-4.1E 0 (0)
( -5.0 - 2.4)E 0
( -5.0 - 2.4)E 0
( -7.6 - 1.6)E 0 (0/ 4)
(0/ 4)
(0/ 4)
Zr-95 (8)
-2.5E -1 30 4.2E -1 4.2E -1 (0)
( -4.0 - 2.9)E 0
( -2.7 - 2.0)E 0
( -2.7 - 2.0)E 0 (0/ 4)
(0/ 4)
(0/ 4)
I-131 (8) 4.3E 1 28 4.3E 1 9.8E 0 (0)
( -1.2 - 11.4)E 1
( -1.2 - 11.4)E 1
( -2.6 - 3.7)E 1 (0/ 4)
(0/ 4)
(0/ 4)
Cs-134 (8) 15 2.1E -1 28 2.1E -1
-2.4E -1 (0)
( -6.0 - 12.0)E -1
( -6.0 - 12.0)E -1
( -1.1 - 1.2)E 0 (0/ 4)
(0/ 4)
(0/ 4)
Cs-137 (8) 18
-9.4E -1 30 2.3E -1 2.3E -1 (0)
( -3.7 - 1.0)E 0
( -2.3 - 1.9)E 0
( -2.3 - 1.9)E 0 (0/ 4)
(0/ 4)
(0/ 4)
Ba-140 (8)
-1.2E 1 30
-4.2E 0
-4.2E 0 (0)
( -2.0 - -0.4)E 1
( -1.0 - 0.2)E 1
( -1.0 - 0.2)E 1 (0/ 4)
(0/ 4)
(0/ 4)
- Non-Routine refers to radionuclides that exceeded the Reporting Levels in ODCM Table E-2
- The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 29 Table 3.1 Radiological Environmental Program Summary Connecticut Yankee Nuclear Power Co., Haddam Neck Station (January - December 2003)
MEDIUM: Well Water (WW) UNITS: pCi/liter Indicator Stations Station With Highest Mean Control Stations Radionuclides Mean Station Mean Mean (No. Analyses)
Required Range Range Range Non-Routine* LLD No. Detected** No. Detected** No. Detected**
H-3 (8) 2000 9.0E 1 15 9.0E 1
-7.0E 1 (0)
( -3.8 - 5.0)E 2
( -3.8 - 5.0)E 2
( -2.5 - 1.0)E 2 (0/ 4)
(0/ 4)
(0/ 4)
Mn-54 (8) 15 1.0E -1 15 1.0E -1
-1.1E 0 (0)
( -1.0 - 1.3)E 0
( -1.0 - 1.3)E 0
( -5.9 - 2.1)E 0 (0/ 4)
(0/ 4)
(0/ 4)
Co-58 (8)
-2.1E -1 15
-2.1E -1
-1.2E 0 (0)
( -8.0 - 9.0)E -1
( -8.0 - 9.0)E -1
( -5.0 - 3.0)E 0 (0/ 4)
(0/ 4)
(0/ 4)
Fe-59 (8)
-2.6E 0 16
-8.8E -1
-8.8E -1 (0)
( -6.4 - -0.5)E 0
( -4.4 - 4.9)E 0
( -4.4 - 4.9)E 0 (0/ 4)
(0/ 4)
(0/ 4)
Co-60 (8) 15 3.8E -1 15 3.8E -1
-5.5E -1 (0)
( -3.0 - 13.0)E -1
( -3.0 - 13.0)E -1
( -2.0 - 1.0)E 0 (0/ 4)
(0/ 4)
(0/ 4)
Zn-65 (8) 30
-2.9E 0 16 3.7E 0 3.7E 0 (0)
( -7.1 - 2.9)E 0
( -5.7 - 7.3)E 0
( -5.7 - 7.3)E 0 (0/ 4)
(0/ 4)
(0/ 4)
Zr-95 (8)
-9.3E -1 15
-9.3E -1
-1.5E 0 (0)
( -2.0 - 1.0)E 0
( -2.0 - 1.0)E 0
( -6.3 - 2.5)E 0 (0/ 4)
(0/ 4)
(0/ 4)
I-131 (8)
-3.7E -1 16 2.8E 0 2.8E 0 (0)
( -1.9 - 1.0)E 0
( 2.0 - 42.0)E -1
( 2.0 - 42.0)E -1 (0/ 4)
(0/ 4)
(0/ 4)
Cs-134 (8) 15 1.5E 0 15 1.5E 0 5.7E -1 (0)
( 1.2 - 1.7)E 0
( 1.2 - 1.7)E 0
( -2.1 - 2.6)E 0 (0/ 4)
(0/ 4)
(0/ 4)
Cs-137 (8) 18
-1.3E -1 15
-1.3E -1
-1.1E 0 (0)
( -1.5 - 0.9)E 0
( -1.5 - 0.9)E 0
( -3.1 - 2.0)E 0 (0/ 4)
(0/ 4)
(0/ 4)
Ba-140 (8) 1.5E -1 16 7.0E -1 7.0E -1 (0)
( -1.1 - 2.1)E 0
( -3.1 - 4.1)E 0
( -3.1 - 4.1)E 0 (0/ 4)
(0/ 4)
(0/ 4)
- Non-Routine refers to radionuclides that exceeded the Reporting Levels in ODCM Table E-2
- The fraction of sample analyses yielding detectable measurements (i.e. >3 standard deviations) is shown in parentheses.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 30 Table 3.2 Environmental TLD Measurements 2003 ENVIRONMENTAL TLD DATA
SUMMARY
CONNECTICUT YANKEE NUCLEAR POWER STATION (JANUARY - DECEMBER 2003)
(uR/hr)
INDICATOR TLDs MEAN RANGE (N0. MEASUREMENTS)*
CONTROL TLDS MEAN RANGE (N0. MEASUREMENTS)*
HIGHEST MEAN (14-C)
MEAN RANGE (N0. MEASUREMENTS)*
EXTRA TLDS MEAN RANGE (N0. MEASUREMENTS)*
ISFSI TLDS MEAN RANGE (N0.
MEASUREMENTS)*
6.2
+/-
0.5 6.1
+/-
0.9 7.5
+/-
0.4 7.2
+/-
1.5 7.0
+/-
0.4 5.2 7.2 5.1 8.0 6.9 8.0 5.6 11.2 6.4 7.7 40 16 4
36 15
- Each "measurement" is based typically on quarterly readings from five TLD elements. Units are micro-R per hour.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 31 Table 3.3 ENVIRONMENTAL TLD MEASUREMENTS 2003 (Micro-R per hour)
ANNUAL Sta.
1ST QUARTER 2ND QUARTER 3RD QUARTER 4TH QUARTER AVE.
No.
Description EXP.
S.D.
EXP.
S.D.
EXP.
S.D.
EXP.
S.D.
EXP.
CY-1-I Onsite Disharge Can 5.34
+/-
0.47 5.53
+/-
0.38 5.94
+/-
0.28 5.82
+/-
0.15 5.7 CY-2-I Haddam Park Road 5.55
+/-
0.42 5.63
+/-
0.26 6.16
+/-
0.27 5.67
+/-
0.16 5.8 CY-3-I Haddam Jail Hill Rd.
6.24
+/-
0.43 6.34
+/-
0.31 6.87
+/-
0.37 6.26
+/-
0.21 6.4 CY-4-I Haddam Ranger Road 5.35
+/-
0.47 5.74
+/-
0.38 5.32
+/-
0.19 5.23
+/-
0.14 5.4 CY-5-I Onsite Injun Hol Rd.
6.43 0.49 6.45
+/-
0.38 7.00
+/-
0.21 6.68
+/-
0.34 6.6 CY-6-I Onsite Substation 7.00
+/-
0.49 6.13
+/-
0.31 6.51
+/-
0.25 6.06
+/-
0.20 6.4 CY-7-I Haddam 6.33
+/-
0.46 6.90
+/-
0.40 6.73
+/-
0.25 7.00
+/-
0.65 6.7 CY-8-I East Haddam 5.75
+/-
0.42 6.11
+/-
0.29 6.41
+/-
0.36 6.45
+/-
0.52 6.2 CY-9-I Higganum 6.05
+/-
0.59 6.09
+/-
0.33 6.53
+/-
0.40 6.18
+/-
0.12 6.2 CY-10-I Hurd Park Road 6.27
+/-
0.50 6.52
+/-
0.35 6.74
+/-
0.30 7.23
+/-
0.45 6.7 CY-11-C Middletown 5.09
+/-
0.37 5.43
+/-
0.27 5.44
+/-
0.24 5.52
+/-
0.16 5.4 CY-12-C Deep River 5.97
+/-
0.44 6.25
+/-
0.31 6.47
+/-
0.22 6.24
+/-
0.64 6.2 CY-13-C North Madison 5.19
+/-
0.44 5.23
+/-
0.46 5.70
+/-
0.19 5.28
+/-
0.11 5.4 CY-14-C Colchester 6.93
+/-
0.53 7.66
+/-
0.37 7.96
+/-
0.43 7.31
+/-
0.14 7.5 CY-40-X*
Near Intake Structur 6.05
+/-
0.42 6.14
+/-
0.30 7.08
+/-
0.40 6.79
+/-
0.31 6.5 CY-41-X*
Picnic area 5.62
+/-
0.43 6.21
+/-
0.49 6.19
+/-
0.20 6.40
+/-
0.94 6.1 CY-42-X*
Environmental Trail 8.16
+/-
0.53 8.31
+/-
0.38 9.82
+/-
0.58 9.15
+/-
0.38 8.9 CY-43-X*
Moodus-Rts 149&151 6.53
+/-
0.45 7.12
+/-
0.38 7.48
+/-
0.31 7.19
+/-
0.30 7.1 CY-44-X*
Shailerville Horton Rd.
5.84
+/-
0.44 5.79
+/-
0.33 6.15
+/-
0.22 6.09
+/-
0.12 6.0 CY-45-X*
Old Waste Gas Sphere 9.56
+/-
0.67 10.59
+/-
0.51 11.18
+/-
0.74 10.28
+/-
0.30 10.4 CY-46-X*
Discharge Canal Fen 6.41
+/-
0.58 7.25
+/-
0.34 7.77
+/-
0.27 7.29
+/-
0.37 7.2 CY-47-X*
Visitor Info Center 6.97
+/-
0.52 6.88
+/-
0.32 7.93
+/-
0.26 7.55
+/-
0.27 7.3 CY-48-X*
Met Shack 5.73
+/-
0.41 5.65
+/-
0.27 5.75
+/-
0.23 6.07
+/-
0.21 5.8 CY-52-IF**
Schmidt Cemetery Onsite 6.41
+/-
0.45 6.48
+/-
0.23 6.51
+/-
0.23 6.5 CY-53-IF**
ISFSI Haul Route Onsite 6.62
+/-
0.33 7.10
+/-
0.23 6.85
+/-
0.20 6.9 CY-54-IF**
RT 149 Salmon River 7.29
+/-
0.37 7.71
+/-
0.34 7.48
+/-
0.26 7.5 CY-55-IF**
HV Tower NW of Pad 6.96
+/-
0.33 7.21
+/-
0.22 6.85
+/-
0.27 7.0 CY-56-IF**
Burrow Pit Onsite 6.79
+/-
0.35 7.03
+/-
0.24 6.97
+/-
0.40 6.9 Extra TLD locations not required by the REMODCM ISFSI TLD Locations
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 32 4.0 ANALYSIS OF ENVIRONMENTAL RESULTS 4.1 Sampling Program Deviations The Radiological Effluent Monitoring Manual (REMM) states in Section E.1 that the environmental sampling and analysis program shall be conducted as specified in Table E-1 for locations shown in Appendix G of the ODCM. Deviations are permitted from the required sampling schedule if specimens are unobtainable due to hazardous conditions, seasonal unavailability, malfunction of automatic sampling equipment or other legitimate reasons. If specimens are unobtainable due to sampling equipment malfunction, every effort shall be made to complete corrective action prior to the end of the next sampling period.
All deviations from the sampling schedule shall be documented in the Annual Radiological Environmental Operating Report pursuant to Section F.1 of the REMM. The following deviations are noted for the 2003-sampling program:
On February 10th, the ISCO sampler for station 28-I went off-line due to the sampling tube popping out of the collection sink. The sampler was repaired by CY and put back on line. On February 24th, Normandeau added a hose clamp to prevent this from occurring in the future.
In the process of replacing the vacuum gauge at air particulate sampling station 5-I on March 25th, the equipment was inadvertently left off. The station was discovered off between 1000 and 1430 and reported to Normandeau. Normandeau returned to and started the station at 1500.
Broad leaf vegetation samples were not collected from stations 6-I, 13-C, 18-I and 41-X during April. Due to the cool spring, leaf development was not at a stage where sampling was feasible.
A partial air particulate filter sample was collected at station 13-C on September 8th because the vacuum pump was found to have failed. A new vacuum pump was purchased and installed on September 9th.
A composite sample was unable to be collected at river water sampling station 28-I on October 20th due to the technician hitting the program button during collection on October 6th, therefore disabling the sampler.
A grab sample was taken in place of the composite sample.
A composite sample was unable to be collected at river water sampling station 28-I on November 17th because the ISCO sampler is being taken out of service for a few weeks while the sampler shed was replaced. A grab sample was taken in place of the composite sample.
The air particulate sampler at station 9-I was found to be off on December 15th. Phone notification (message recording) was made to plant staff and EE/NC #12-29-03-1 was completed. The sample was determined to be a valid partial sample. On December 29th, station 9-I was found to be still without power (EE/NC #12-29-03-2 was written). The December 29th sample was determined to be a void sample for the entire collection period. An approved change to the REMP Standard Operating Procedures was made ensure that future notifications of equipment inoperability status are effectively identified to the responsible parties needing to implement corrective actions.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 33 4.2 Comparison of Achieved LLD with Requirements Table E-3 of the REMODCM (Table 2.3 in this report) lists the required Lower Limits of Detection (LLDs) for routine environmental sample analyses. On occasion, an LLD is not achieved due to situations such as a low sample volume. In such a case, the REMODCM requires the identification and discussion of the contributing factors in the Annual Radiological Environmental Operating Report. At the FANPEL, the target LLD for any analysis is typically 30-40 percent of the most restrictive required LLD. Expressed differently, the typical sensitivities achieved for each analysis are at least 2.5 to 3 times better than that required by the REMODCM.
For each analysis having an LLD requirement the a posteriori or after the fact LLD calculated for that analysis was compared with the required LLD. Of the more than 300 analyses performed with a specified LLD requirement, one sample did not meet the requirements of the ODCM in 2003. A gross beta analysis sample for an air particulate taken at Station 13 on September 8, 2003 failed to achieve the LLD due to low volume.
4.3 Results Compared Against Reporting Levels The REMODCM Section E requires the written notification to the NRC within 30 days whenever a Reporting Level in ODCM Table E-2 is exceeded (Table 2.4 in this report). Reporting Levels are the environmental concentrations that relate to the ALARA design dose objectives of 10 CFR 50, Appendix I. It should be noted that environmental concentrations are averaged over calendar quarters for the purposes of this comparison, and that Reporting Levels apply only to measured levels of radioactivity due to plant effluents. During 2003, no Reporting Levels were exceeded.
4.4 Data Analysis by Media Type The 2003 REMP data for each media type are discussed below categorized by pathway. Graphical plots of monitoring data are also shown in Figures 4.1 to 4.10. With respect to data plots, all values are plotted, whether they are "detectable" or "non-detectable."
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 34 4.4.1 Air Particulate Gross Beta Radioactivity Air particulates are collected on glass fiber filters bi-weekly at four indicator locations and one control location, and analyzed for gross beta radioactivity. Gamma isotopic analyses are performed on the quarterly composites of each location.
As shown in Figure 4.1, there is no significant difference between the average gross beta concentration at the indicator stations and the control station. Notable in the graph is the distinct annual cycle.
FIGURE 4.1 GROSS BETA MEASUREMENTS ON AIR PARTICULATE FILTERS (QUARTERLY AVERAGES) 0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 1997 1998 1999 2000 2001 2002 2003 pCi/cubic meters 0
0.01 0.02 0.03 0.04 0.05 0.06 0.07 Control Stations Indicator Stations
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 35 Figure 4.2 shows the biweekly gross beta concentrations at each sampling location required by the ODCM along with the control station in North Madison. The gross beta concentration is seen to fluctuate over the year due to seasonal changes in the naturally occurring airborne radioactivity. The gross beta concentrations at the indicator stations are similar to the control station and fluctuate in the same manner.
Figure 4.2 Connecticut Yankee Running 12 Month Bi-Weekly Air Particulate Gross Beta Analysis Results 0.0E+00 1.0E-02 2.0E-02 3.0E-02 4.0E-02 5.0E-02 6.0E-02 1/1 1/15 1/29 2/12 2/26 3/12 3/26 4/9 4/23 5/7 5/21 6/4 6/18 7/2 7/16 7/30 8/13 8/27 9/10 9/24 10/8 10/22 11/5 11/19 12/3 12/17 12/31 Sample Reference Date (2002 - 2003)
Gross Beta Activity (pCi/m3)
Station 5 Station 6 Station 7 Station 9 Station 13 The quarterly composites of the bi-weekly air particulate filters are also analyzed for gamma radioactivity. The results, shown in Tables 3.1, indicate the presence of naturally occurring Be-7, which is produced by cosmic processes. No positive results were observed for all the other isotopes.
4.4.2 River Water River water composite samples were collected quarterly during 2003. The quarterly composites were analyzed for gamma radionuclides and H-3. No gamma emitting radionuclides or H-3 were detected in 2003.
4.4.3 Well Water In 2003, samples of water from the onsite wells (location 15) and control station (location 16) were taken quarterly. The on-site wells have in the past indicated the presence of station related H-3. The H-3 is believed to result from the wells proximity to an area influenced by the water in the discharge canal and the ability of H-3 to migrate. In recent years it was discovered that there was a leak in the Reactor Water Storage Tank (RWST) that migrated to the ground water. This tank was subsequently drained and is now abandoned. As a part of the decommissioning process, a series of groundwater monitoring wells were installed. The results of the ground water monitoring evaluation can be found in the Malcolm Pirnie Ground Water Monitoring Report for Connecticut Yankee Atomic Power Company, Final Report, September 1999.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 36 A downward trend has been observed in the H-3 concentration from the onsite wells since cycle 17 in 1992 due to the replacement of stainless-steel clad fuel with zircaloy clad fuel. The levels of H-3 observed since permanent shutdown in July 1996 represent residual levels of tritium that remain in station process liquids and/or groundwater from beneath the site that are gradually dropping to natural background levels. For 2003, no H-3 was detected in either the indicator or the control stations.
Figure 4.3 shows the H-3 concentration in CY on-site wells since 1988. The concentrations plotted for 2003 represent statistically non-positive H-3 concentrations.
Figure 4.3 H-3 Levels in On-site Wells
-1000 0
1000 2000 3000 4000 5000 6000 7000 1Q88 1Q89 1Q90 1Q91 1Q92 1Q93 1Q94 1Q95 1Q96 1Q97 1Q98 1Q99 1Q00 1Q01 1Q02 1Q03 Year pCi/liter pCi/l non-positive
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 37 4.4.4 Bottom Sediment Semiannual grab samples of river bottom sediments were collected, dried and analyzed for gamma emitting radionuclides.
Cs-137 was detected in five of the six samples. Figure 4.4 shows that historically, Cs-137 has been detected at both the control and indicator locations indicating that the likely source is weapons fallout. One of the samples collected at the indicator station in the vicinity of the discharge also contained Co-60. The level of Co-60 measured in 2003 is bounded by concentrations observed in previous years as shown in Figure 4.5. No other indications of station related radioactivity were observed in this sample media. Naturally occurring K-40 and Th-232 were also detected in all of the samples.
FIGURE 4.4 CS-137 IN SEDIMENT
-500 0
500 1000 1500 2000 Mar-98 Sep-98 Mar-99 Sep-99 Mar-00 Sep-00 Mar-01 Sep-01 Mar-02 Sep-02 Mar-03 Sep-03 pCi / Kg
-500 0
500 1000 1500 2000 Station 28 Station 29 Station 30 Station 28 Positive Analysis Station 29 Positive Analysis Station 30 Positive Analysis FIGURE 4.5 CO-60 IN SEDIMENT
-500 0
500 1000 1500 2000 Mar-97 Sep-97 Mar-98 Sep-98 Mar-99 Sep-99 Mar-00 Sep-00 Mar-01 Sep-01 Mar-02 Sep-02 Mar-03 Sep-03 pCi / Kg
-500 0
500 1000 1500 2000 Station 28 Station 30 Station 29 Station 29 Positive Concentrations
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 38 4.4.5 Fruits and Vegetables Four vegetable samples analyzed for gamma emitting nuclides indicate only the presence of naturally occurring K-40.
4.4.6 Broad Leaf Vegetation Vegetation was collected from two indicator and one control station. In addition, samples were collected from an extra sampling location, 41-X, that is not part of the required REMP. K-40 was observed in all the samples and Cs-137 was detected in two out of eighteen samples from indicator stations and two out of six samples from the control station. The source of this non-edible vegetation is taken from shrubs/woody plants coincidentally growing at the specific monitoring location. The varying amount of Cs-137 present in the samples is likely due to different Cs-137 soil concentrations and uptake rates from the soil.
4.4.7 Shellfish Shellfish samples were collected semiannually from two locations. Naturally occurring Th-232 was detected in two control samples. No other gamma emitting radionuclides were detected in the samples.
4.4.8 Fish Multiple fish samples were collected semiannually at three locations. The species collected in 2003 were perch, bullheads and catfish. Cs-137 was observed in one indicator sample (bottom feeder fish). K-40 was detected in all the samples.
Although the presence of Cs-137 in this media is historically attributed to residual weapons fallout, the Cs-137 in fish is conservatively treated as a possible plant related nuclide to assess the dose consequence in Section 5.
Two special fish samples were collected at the Windsor and Haddam stations for additional analysis. Fish bones collected from these two stations mentioned was tested for the presence of Strontium-89 and Strontium-90. Gamma isotopic analyses were performed on the fish flesh samples. These special samples results are included in Table 3.1.
4.4.9 Gamma Exposure Rate Direct radiation is continuously measured at 14 locations surrounding Haddam Neck Station and at nine extra on-site locations with thermoluminescent dosimeters (TLDs). The extra on-site locations are not part of the REMP but are used to monitor the impact of on-site decommissioning activities on the site boundary doses. All TLDs are collected quarterly for readout at the FANPEL.
Tables 3.2 and 3.3 show the mean exposure rates for the Indicator and Control categories do not vary significantly in 2003.
As shown in Figure 4.6, there is a distinct annual cycle at both indicator and control locations. The lowest point of the cycle occurs during the winter months. This is due primarily to the attenuating effect of the snow cover on radon emissions and on direct irradiation by naturally-occurring radionuclides in the soil. Differing amounts of these radionuclides in the underlying soil, rock or nearby building materials result in different radiation levels between one field site and another.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 39 Figure 4.7 shows the exposure rate at all the Indicator TLD locations. In 2000, the TLDs (Victoreen glass bulb CaF2(Mn))
which had historically been used to measure direct radioactivity around Connecticut Yankee for over 20 years were replaced with Panasonic model UD-804 AS1 TLD. The changeover occurred in February, 2000. The Victoreen glass bulb type TLDs were subject to inherent self-irradiation which was experimentally measured for each dosimeter. This correction for field dosimeters averaged approximately 1 µR/hr. In general, the new Panasonic monthly dosimeters show an average decrease in measured exposure rate by -20% compared to the historical average determined by the Victoreen monthly dosimeters.
Figure 4.6 Average Exposure Rate at Indicator, Control and Extra TLDs 0.00 5.00 10.00 15.00 1998 1999 2000 2001 2002 2003 2004 Micro-R er Hour 0.00 5.00 10.00 15.00 Indicators Control Extra TLDs Figure 4.7 Exposure Rate at Indicator Locations 0
2 4
6 8
10 12 14 1998 1999 2000 2001 2002 2003 2004 Micro-R per Hour 1-I 2-I 3-I 4-I 5-I 6-I 7-I 8-I 9-I 10-I
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 40 Figure 4.8 shows the exposure rate at the nine Extra TLD locations used to monitor more closely on-site decommissioning activities. An increased exposure rate was observed at on-site location #45-X throughout the 2000 and into 2002. This increase was noted toward the end of 1999, coincident with the removal of the steam generators and pressurizer from containment. These components were temporarily stored in the Southeast corner of the Industrial Area 700 feet from location
- 45-X. The increase in exposure rate due to these components is a localized effect and does not affect an increase in exposure beyond the owner controlled area. The steam generators, reactor head and pressurizer were shipped off site between the second and fourth quarter of 2002. TLD measurements throughout the year demonstrate the general variations in background radiation between the various on-site and off-site locations and include gamma exposure from all sources of radioactivity.
Figure 4.8 Exposure Rate at Extra TLD Locations 0
2 4
6 8
10 12 14 16 18 20 1998 1999 2000 2001 2002 2003 2004 Micro-R per Hour 40x 41x 42x 43x 44x 45x 46x 47x 48x
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 41 4.4.10 ISFSI Gamma Exposure Rate In the second quarter of 2003, additional sampling locations associated with the placement on-site of an Independent Spent Fuel Storage Installation (ISFSI) were selected for the purpose of collecting baseline background information prior to the transfer of spent fuel from the main plant to the ISFSI. These new locations are specific to the ISFSI and are beyond the standard REMP that has been in operation over the life of the power plants license. New quarterly TLD locations were located in the area surrounding the facility at distances that approximated the site boundary to support future determinations that direct and scatter dose from ISFSI operations remain in compliance with offsite dose limits to the public.
In addition, two locations associated with a hypothetical water pathway were selected for sediment and water sample collections to help confirm that ISFSI operations will have no impact on the wetlands. Figure 4.9 shows the CS-137 levels that exists at both ISFSI sediment locations. Table 3.1 shows that no plant-related nuclides were identified in any of these samples.
Figures 4.10 and 4.11 summarize the 2003 results of the baseline measurements associated with the new ISFSI sampling program.
Figure 4.9 CS-137 in ISFSI Sediment 0
100 200 300 400 500 600 Jun-03 Jun-03 Jul-03 Jul-03 Jul-03 Aug-03 Aug-03 Aug-03 Sep-03 Sep-03 Sep-03 pCi/Kg Station 57 Station 57 Positive Analysis Station 58 Station 58 Positive Analysis
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 42 Figure 4.10 Average Exposure Rates at ISFSI TLDs 0.00 5.00 10.00 15.00 Jun-03 Sep-03 Dec-03 Micro-R per Hour ISFSI TLDs Figure 4.11 Exposure Rate at ISFSI TLD Locations 0
2 4
6 8
10 12 14 May-03 Jun-03 Aug-03 Oct-03 Nov-03 Jan-04 Micro-R per Hour 52x 53x 54x 55x 56x
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 43 5.0 OFF-SITE DOSE EQUIVALENT COMMITMENTS The purpose of this section is to evaluate off-site dose consequences (dose equivalent commitments) associated with the stations' radioactive liquid and airborne effluents. The method utilizes Regulatory Guide 1.109 / REMODCM models and actual measurements of the concentrations of radioactivity in environmental media to compute the dose consequences resulting from the consumption of these foods.
The standards for the maximum dose to an individual of the general public, taken from 40CFR190, is 25 mRem to the whole body, 75 mRem to the thyroid and 25 mRem to any other organ. These standards are a fraction of the average USA background radiation of 300 mRem per year given in NCRP94.
During 2003, Co-60 was identified in the bottom sediment in the area of the plant discharge. Although this nuclide is attributable to plant related operations in past years, these samples represent a pathway that is not involved with a significant exposure to the public. Cs-137 was measured in one out of eighteen fish samples and although attributed to weapons fallout a potential annual dose commitment to a maximum exposed individual of 0.035 mRem (Teen Liver) has been estimated using conservative assumptions regarding consumption rate and a constant Cs-137 concentration of 45 pCi/kg in fish. This dose is 0.14% of the standard dose of 25 mRem.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 44
6.0 REFERENCES
- 1. USNRC Radiological Assessment Branch Technical Position, "An Acceptable Radiological Environmental Monitoring Program," Revision 1, November 1979.
- 2. NCRP Report No. 94, Exposure of the Population in the United States and Canada from Natural Background Radiation, National Council on Radiation Protection and Measurements, 1987.
- 3. Ionizing Radiation: Sources and Biological Effects, United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), 1982 Report to the General Assembly.
- 4. Kathren, Ronald L., Radioactivity and the Environment - Sources, Distribution, and Surveillance, Harwood Academic Publishers, New York, 1984.
Subject:
Implementation of Programmatic Controls for Radiological Effluent Technical Specifications in the Administrative Controls Section of the Technical Specifications and the Relocation of Procedural Details of RETS to the Offsite Dose Calculation Manual or to the Process Control Program. Dated January 31, 1989.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 A-1 APPENDIX A LAND USE CENSUS FOR 2003
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 A-2 2003 Land Use Census Assessment The results of the 2003 Land Use Census are included in this report in compliance with REMODCM Section E-2. The locations identified during the Census are listed in Table A-1. In 2003, Normandeau Associates conducted the Land Use Census and verified the distance and direction for all residence and garden locations with a portable Global Positioning System (GPS).
The CY REMMODCM requires that milk sampling be initiated as part of the REMP if the annual Land Use Census identifies milk animals within 5 km (3 miles) from the site (three indicator locations having the highest dose potential). If no milking animals are located within 5 km (3 miles) then samples of milking animals from three locations between 3 and 5 mile that exceed a dose potential of 1 mrem/year shall be added to the Radiological Environmental Monitoring Program. The 2003 Land Use Census did not find any milk locations within 5 km (3 miles), and did not identify any new milk animal locations between 5-8 km (3-5 miles). However, a dairy farm was identified just outside of 5 miles (5.36 miles) in the NE sector. Also, two goat farms which were identified in the 2002 land use census in the N and SSE sector continue to be in business. However, an analysis of the potential dose impact associated with these locations indicated that none had a potential dose that would be expected to exceed 1 mrem/year (Ref. 2). As a result, milk sampling need not be included as part of the sampling program.
The dose assessment methodology used the milk pathway model from Regulatory Guide 1.109 in conformance with the requirement of the CY ODCM. Both cows and goats were assumed to be on pasture for the entire growing season receiving their entire daily food intake from pasture (i.e., no stored feed). The milk pathway dose analysis also utilized the recorded gaseous effluents from the plant in 2000 as an indicator of reasonable source term. The source term included three particulate species (Co-60 at 85.6% of the particulate total, Cs-137 at 6.6%, and Mn-54 at 7.8%) and tritium. Tritium accounted for over 99.99% of the total radioactivity recorded discharge in gaseous effluents. No iodine is included since these radionuclides (I-131 and I-133) have been removed from the potential source term due to natural decay and the permanent shut of the plant in 1996. Five-year average historical meteorological dispersion conditions were reviewed to find the most limiting dispersion parameters in any sector from 3 mile or further from the plant. The selected bounding dispersion factors were for the 9 month growing season between April and December for the ESE direction at approximately 3 miles (depleted X/Q = 1.15E-06 sec/m3, and the D/Q = 2.52E-09 1/m2). Usage factors for animal feed and human uptake were also taken from Regulatory Guide 1.109 as applied to the maximum individual.
The limiting dose to any organ was found to be from goat milk and equaled only 2.64E-03 mrem/year (infant liver). This dose impact is over a factor of 378 times smaller than the 1-mrem/year criteria used to decide if milk samples need to be included in the REMP. This large margin ensures that any expected deviations in annual radioactivity releases from the plant will not cause the predicted dose impact for the milk pathway to exceed 1 mrem/year.
Broad leaf vegetation samples are collected at the site boundary in two different sectors with high D/Q values as indicated in the REMP collection schedule. This media acts as an indicator for ingestion pathways associated with garden food products located beyond the plant site. In 2003, a garden census was conducted in addition to the ongoing required sampling of vegetation at the two site boundary locations, 6-I and 18-I. As shown in Table A.1, there were several changes from the 2002 garden survey noted during 2003. A comparison of the D/Q values indicates that none of the census locations had a 20% higher potential dose commitment than at either of the two boundary locations.
Pursuant to REMODCM Section E-2, any sampling changes resulting from the Land Use Census must be noted in this report. For 2003, no changes in the REMP need to take place.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 A-3 TABLE A.1 2003 LAND USE CENSUS LOCATIONS SECTOR NEAREST RESIDENCE Km NEAREST GARDEN Km NEAREST MILK ANIMAL (Goat)
Miles N
1.18 3.42 4.0 NNE 1.74 2.23 NE 1.69 3.43 5.4**
ENE 1.75 2.39 E
2.12 2.40 ESE 2.75 3.08 SE 1.34 2.07 SSE 1.20 3.9 S
1.04 1.28 SSW 0.93 2.73 SW 1.03 1.24 WSW 1.22 W
1.40 1.66 WNW 0.64 3.01 NW 1.09 2.17 NNW 1.55 2.43
New location in 2003
-- Garden location eliminated in 2003 No cow or goat identified in this sector within 5 miles of the plant.
- Holstein cows identified in 2003.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 B-1 APPENDIX B Quality Assurance Program
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 B-2 Quality Assurance Program The quality assurance program at the Framatome ANP Environmental Laboratory (FANPEL) is designed to serve two overall purposes: 1) Establish a measure of confidence in the measurement process to assure the licensee, regulatory agencies and the public that analytical results are accurate and precise; and 2) Identify deficiencies in the sampling and/or measurement process to those responsible for these operations so that corrective action can be taken. Quality assurance is applied to all steps of the measurement process, including the collection, measurement and reporting of data, as well as the record keeping of the final results. Quality control, as part of the quality assurance program, provides a means to control and measure the characteristics of the measurement equipment and processes, relative to established requirements.
The FANPEL employs a comprehensive quality assurance program designed to monitor the quality of analytical processing to ensure reliable environmental monitoring data. The program includes the use of controlled procedures for all work activities, a nonconformance and corrective action tracking system, systematic internal audits, audits by external groups, a laboratory quality control program, and a staff training program. Monitoring programs include the Intralaboratory Quality Control Program administered by the Laboratory QA Officer (used in conjunction with the National Institute of Standards and Technology Measurement Assurance Program, NIST MAP) and a third party cross check program administered by Analytics, Inc. Together these programs are targeted to supply QC/QA sources at 5% of the client sample analysis load. In addition the Laboratory Quality Control Audit Committee administers a blind duplicate program conducted through client environmental monitoring programs.
This summary reports all intralaboratory and third party results received by FANPEL on or before December 31, 2003.
Intralaboratory Quality Control Program The FANPEL QA Officer administers an extensive intralaboratory quality control program in which process check samples are submitted for analysis. These samples are submitted either in duplicate to evaluate the precision of a measurement process or are spiked with a known amount of radioactive material to assess the bias in the measurement.
Table B.1 provides the summary of the process check results for January to December 2003. Of the 407 analyses, 98.0%
passed the bias criteria and 100% of the 135 results evaluated for precision were acceptable. The FANPEL internal acceptance criteria are summarized at the end of Table B.1.
Third Party Cross Check Program The FANPEL participates in a third party cross check program managed by Analytics Inc. to satisfy the requirement of the Environmental Technical Specification/ODCM. The FANPEL Analytics program was originally used to augment the EPA Intercomparison Program that it now replaces. The current program is designed to be comparable to the pre-1996 EPA PE Program in terms of the number of samples, matrices and nuclides. The results for the 4th quarter 2002 through the 3rd quarter 2003 are summarized in Table B.2. Each sample is normally analyzed in triplicate and the results are evaluated against the internal acceptance criteria described in the FANPEL Manual 100-Laboratory Quality Assurance Plan. This acceptance protocol is used for all interlaboratory programs with no pre-set acceptance criteria. When results fall outside of the acceptance criteria, an investigation is initiated to determine the cause of the problem and if appropriate, corrective measures are taken. The FANPEL internal acceptance criteria are summarized at the end of Table B.1.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 B-3 Blind Duplicate Program Under the Blind Duplicate Quality Assurance Program, samples are split from homogeneous environmental media by the client and sent to the FANPEL for analysis. They are "blind" in that the identification of the matching sample is not identified to the Laboratory.
Participating clients submitted a total of 22 paired samples in 2003. The measurements evaluated include twenty-six gamma emitting radionuclides, H-3, and gross-beta. All measurements are evaluated, whether the results are statistically positive or not, and whether the net concentration is positive or negative.
The samples submitted as part of this program are listed in Table B.3. For the 2003 program, 99.6% (482/484) of the measurements met the FANPEL internal acceptance criteria.
Environmental TLD Quality Assurance Program Performance documentation of the routine processing of the Panasonic environmental TLDs (thermoluminescent dosimeter) program at the FANPEL is provided by the dosimetry quality assurance testing program. This program includes independent third party performance testing by Battelle Pacific Northwest Labs and internal performance testing conducted by the Laboratory QA Officer. Under these programs, sets of six dosimeters are irradiated to ANSI specified testing criteria and submitted for processing to the Dosimetry Services Section as unknowns. The bias and precision of TLD processing is measured against this standard and is used to indicate trends and changes in performance.
Instrumentation checks, although routinely performed by the Dosimetry Services Group and representing between 5-10%
of the TLDs processed, are not presented in this report because they do not represent a true process check sample since the exposures are known to the processor.
Ninety performance tests were conducted in 2003 by FANPEL and the third party tester. These tests were made on 15 separate sets of 6 dosimeters. All of the 15 TLD test sets passed the mean bias criteria of +/-20.1%. Of the ninety individual measurements, 100% of the dosimeter evaluations met the FANPEL Internal Acceptance Criteria for bias
(+/-20.1%) and precision (+/-12.8%). Third Party QC results are summarized below.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 B-4 Percentage of Individual Analyses that passed FANPEL Internal Criteria Dosimeter Type Number Tested
% Passed Bias Criteria
% Passed Precision Criteria Panasonic Environmental 90 100 100 Summary of Third Party Testing Dosimeter Type Exposure Period ANSI Category
% (Bias +/- SD)
Panasonic Environmental Q4/2002 II, high energy 4.2 +/- 1.2 Q1/2003 II, high energy 6.1 +/- 8.6 Q2/2003 II, high energy 1.8 +/- 1.4 Q3/2003 II, high energy 3.2 +/- 0.9
- American National Standards Institute (ANSI) Performance Statistic as referenced in the Dosimetry Services Semi-Annual QA Status Report.
Note: Results are expressed as the delivered exposure for environmental TLD. ANSI HPS N13.29-1995 (Draft) Category II, High energy photons (Cs-137 or Co-60).
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 B-5 TABLE B.1 FANPEL RESULTS IN THE INTRALABORATORY PROCESS CONTROL PROGRAM January - December 2003 Bias Criteria (1)
Precision Criteria (2)
Media Analysis 1
2 3
4 1
2 3
4 I. Air Charcoal Gamma 22 2
0 0
0 0
0 0
II. Air Filter Alpha Beta 206 10 0
1 0
0 0
0 Gamma III. Milk Gamma Iodine-LL 9
1 0
0 10 0
0 0
Strontium-89 0
4 1
0 3
1 1
0 Strontium-90 0
2 3
0 1
4 0
0 IV. Water Gross Alpha 7
12 14 4
2 0
8 0
Gross Beta 34 12 2
0 8
2 4
0 Gamma 14 0
0 0
0 2
22 0
Iodine-LL 5
0 0
0 5
0 0
0 Sr-90 2
2 1
0 0
0 6
0 Tritium 21 5
1 0
26 6
12 0
V. Sediment/Soil Gamma 2
0 0
0 0
0 0
0 Pu-238 1
0 0
0 4
0 0
0 Pu-239 0
1 1
1 4
0 0
0 Am-241 2
0 0
2 0
4 0
1 Total Number in Range 325 51 23 8
63 19 53 0
Percentage of Total Processed 79.9 12.5 5.7 2.0 46.7 14.1 39.3 0.0 Sum of Analyses 407 135 (1) Percent Bias Criteria by Bias Category (2) Percent Precision Criteria by Precision Category Bias Category = 1 > 0% and < = 5%
Precision Category = 1 > 0% and < = 5%
Bias Category = 2 > 5% and < = 10%
Precision Category = 2 > 5% and < = 10%
Bias Category = 3 > 10% and < = 15%, or Precision Category = 3 > 10% and < = 15%, or within 2 sigma of known within 2 sigma of mean Gross alpha/beta water, Sr 89/90 > 10% and < = 25%
Precision Category = 4 Outside Criteria Transuranics > 10% and < = 20%
Bias Category = 4 Outside Criteria
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 B-6 TABLE B.2 FANPEL RESULTS IN THE ANALYTICS INC. CROSS CHECK PROGRAM Quarter 4, 2002 - Quarter 3, 2003 Ratio Sample Quarter/
Sample Reported Known E-LAB/
Number Year Media Nuclide Value*
Value*
Analytics Evaluation E3461-162 4th/2002 Water H-3 5450 5987 0.91 Agreement E3462-162 4th/2002 Water Sr-89 72 79 0.91 Agreement 4th/2002 Sr-90 16 16 1.00 Agreement E3463-162 4th/2002 Filter Gross Alpha 52 59 0.88 Agreement 4th/2002 Gross Beta 147 150 0.98 Agreement E3464-162 4th/2002 Filter Ce-141 59 59 1.00 Agreement 4th/2002 Cr-51 184 184 1.00 Agreement 4th/2002 Cs-134 51 53 0.96 Agreement 4th/2002 Cs-137 125 117 1.07 Agreement 4th/2002 Co-58 75 74 1.01 Agreement 4th/2002 Mn-54 83 75 1.11 Agreement 4th/2002 Fe-59 43 38 1.13 Agreement 4th/2002 Zn-65 103 95 1.08 Agreement 4th/2002 Co-60 84 87 0.97 Agreement E3465-162 4th/2002 Filter Sr-89 68 75 0.91 Agreement 4th/2002 Sr-90 61 60 1.02 Agreement E3466-162 4th/2002 Milk I-131LL 89.2 86 1.04 Agreement 4th/2002 I-131 81 86 0.94 Agreement 4th/2002 Ce-141 103 111 0.91 Agreement 4th/2002 Cr-51 334 346 0.97 Agreement 4th/2002 Cs-134 98 99 0.90 Agreement 4th/2002 Cs-137 220 220 1.00 Agreement 4th/2002 Co-58 134 139 0.96 Agreement 4th/2002 Mn-54 142 142 1.00 Agreement 4th/2002 Fe-59 74 72 1.03 Agreement 4th/2002 Zn-65 177 178 0.99 Agreement 4th/2002 Co-60 162 164 0.99 Agreement E3597-162 1st/2003 Water Gross Alpha 55 61 0.90 Agreement 1st/2003 Gross Beta 146 186 0.78 Agreement E3598-162 1st/2003 Water I-131LL 67.7 70 0.97 Agreement 1st/2003 I-131 68 70 0.97 Agreement 1st/2003 Ce-141 163 168 0.97 Agreement 1st/2003 Cr-51 243 238 1.02 Agreement 1st/2003 Cs-134 83 88 0.94 Agreement 1st/2003 Cs-137 188 195 0.96 Agreement 1st/2003 Co-58 44 42 1.05 Agreement 1st/2003 Mn-54 61 63 0.97 Agreement
- pCi/Liter (Filters in pCi)
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 B-7 TABLE B.2 (contd)
FANPEL RESULTS IN THE ANALYTICS INC. CROSS CHECK PROGRAM Quarter 4, 2002 - Quarter 3, 2003 Ratio Sample Quarter/
Sample Reported Known E-LAB/
Number Year Media Nuclide Value*
Value*
Analytics Evaluation E3598-162 1st/2003 Water Fe-59 48 46 1.04 Agreement 1st/2003 Zn-65 88 90 0.98 Agreement 1st/2003 Co-60 156 157 0.99 Agreement E3599-162 1st/2003 Filter Gross Alpha 52 49 1.06 Agreement 1st/2003 Gross Beta 157 148 1.06 Agreement E3600-162 1st/2003 Milk I-131LL 72.5 74 0.98 Agreement 1st/2003 I-131 73 74 0.99 Agreement 1st/2003 Ce-141 170 173 0.98 Agreement 1st/2003 Cr-51 244 246 0.99 Agreement 1st/2003 Cs-134 86 90 0.96 Agreement 1st/2003 Cs-137 196 200 0.98 Agreement 1st/2003 Co-58 44 47 0.94 Agreement 1st/2003 Mn-54 61 64 0.95 Agreement 1st/2003 Fe-59 47 47 1.00 Agreement 1st/2003 Zn-65 96 93 1.03 Agreement 1st/2003 Co-60 162 162 1.00 Agreement E3601-162 1st/2003 Milk Sr-89 121 133 0.91 Agreement 1st/2003 Sr-90 13 12 1.08 Agreement E3608-162 1st/2003 Water Sr-89 104 114 0.91 Agreement 1st/2003 Sr-90 11 10 1.10 Agreement E3704-162 2nd/2003 Water H-3 10643 11953 0.89 Agreement E3705-162 2nd/2003 Filter Gross Alpha 20 21 0.95 Agreement 2nd/2003 Gross Beta 116 115 1.01 Agreement E3706-162 2nd/2003 Filter Ce-141 149 154 0.97 Agreement 2nd/2003 Cr-51 134 130 1.03 Agreement 2nd/2003 Cs-134 54 56 0.96 Agreement 2nd/2003 Cs-137 135 125 1.08 Agreement 2nd/2003 Co-58 53 50 1.06 Agreement 2nd/2003 Mn-54 110 101 1.09 Agreement 2nd/2003 Fe-59 60 54 1.11 Agreement 2nd/2003 Zn-65 110 99 1.11 Agreement 2nd/2003 Co-60 71 72 0.99 Agreement E3707-162 2nd/2003 Filter Sr-89 78 87 0.90 Agreement 2nd/2003 Sr-90 24 24 1.00 Agreement E3708-162 2nd/2003 Milk I-131 109 103 1.06 Agreement 2nd/2003 I-131LL 104 103 1.01 Agreement 2nd/2003 Ce-141 283 283 1.00 Agreement 2nd/2003 Cr-51 239 239 1.00 Agreement
- pCi/Liter (Filters in pCi)
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 B-8 TABLE B.2 (contd)
FANPEL RESULTS IN THE ANALYTICS INC. CROSS CHECK PROGRAM Quarter 4, 2002 - Quarter 3, 2003 Ratio Sample Quarter/
Sample Reported Known E-LAB/
Number Year Media Nuclide Value*
Value*
Analytics Evaluation E3708-162 2nd/2003 Milk Cs-134 98 103 0.95 Agreement 2nd/2003 Cs-137 232 230 1.01 Agreement 2nd/2003 Co-58 92 93 0.99 Agreement 2nd/2003 Mn-54 186 186 1.00 Agreement 2nd/2003 Fe-59 100 99 1.01 Agreement 2nd/2003 Zn-65 181 181 1.00 Agreement 2nd/2003 Co-60 134 132 1.02 Agreement E3866-162 3rd/2003 Water Gross Alpha 37 36 1.03 Agreement 3rd/2003 Gross Beta 242 246 0.98 Agreement E3867-162 3rd/2003 Water I-131 69 76 0.91 Agreement 3rd/2003 I-131LL 78 76 1.03 Agreement 3rd/2003 Ce-141 78 81 0.96 Agreement 3rd/2003 Cr-51 198 221 0.90 Agreement 3rd/2003 Cs-134 108 113 0.96 Agreement 3rd/2003 Cs-137 85 84 1.01 Agreement 3rd/2003 Co-58 92 94 0.98 Agreement 3rd/2003 Mn-54 93 88 1.06 Agreement 3rd/2003 Fe-59 74 75 0.99 Agreement 3rd/2003 Zn-65 170 166 1.02 Agreement 3rd/2003 Co-60 118 117 1.01 Agreement E3868-162 3rd/2003 Filter Gross Alpha 30 28 1.07 Agreement 3rd/2003 Gross Beta 197 189 1.04 Agreement E3869-162 3rd/2003 Milk I-131 66 74 0.89 Agreement 3rd/2003 I-131LL 74 74 1.00 Agreement 3rd/2003 Ce-141 90 86 1.03 Agreement 3rd/2003 Cr-51 228 233 0.98 Agreement 3rd/2003 Cs-134 123 119 1.03 Agreement 3rd/2003 Cs-137 94 88 1.07 Agreement 3rd/2003 Co-58 99 99 1.00 Agreement 3rd/2003 Mn-54 101 93 1.09 Agreement 3rd/2003 Fe-59 84 79 1.06 Agreement 3rd/2003 Zn-65 178 176 1.01 Agreement 3rd/2003 Co-60 129 123 1.05 Agreement E3870-162 3rd/2003 Milk Sr-89 80 100 0.80 Agreement 3rd/2003 Sr-90 11 14 0.79 Agreement
- pCi/Liter (Filters in pCi)
Bias and Precision Acceptance Criteria as described above.
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 B-9 TABLE B.3
SUMMARY
OF BLIND DUPLICATE SAMPLES January - December 2003 TYPE OF SAMPLE NUMBER OF PAIRED SAMPLES SUBMITTED Ground Water 2
Surface Water 12 Algae 2
Mussels 2
TOTAL 18
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 C-10 APPENDIX C Data Summary
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 C-1 AIR PARTICULATE AP 5
L4665-01 1/13/2003 GROSS BETA 2.05E-02 1.40E-03 3.50E-03 AP 5
L4750-01 1/27/2003 GROSS BETA 2.66E-02 1.30E-03 2.40E-03 AP 5
L4853-01 2/10/2003 GROSS BETA 2.35E-02 1.30E-03 2.70E-03 AP 5
L4936-01 2/24/2003 GROSS BETA 1.82E-02 1.40E-03 3.60E-03 AP 5
L5068-01 3/10/2003 GROSS BETA 3.17E-02 1.50E-03 3.10E-03 AP 5
L5133-01 3/24/2003 GROSS BETA 2.06E-02 1.40E-03 3.50E-03 AP 5
L5233-01 4/7/2003 GROSS BETA 1.63E-02 1.30E-03 3.30E-03 AP 5
L5324-01 4/21/2003 GROSS BETA 2.22E-02 1.30E-03 2.50E-03 AP 5
L5416-01 5/5/2003 GROSS BETA 1.53E-02 1.20E-03 2.60E-03 AP 5
L5479-01 5/19/2003 GROSS BETA 9.78E-03 8.50E-04 2.10E-03 AP 5
L5565-01 6/2/2003 GROSS BETA 1.12E-02 1.00E-03 2.80E-03 AP 5
L5656-01 6/16/2003 GROSS BETA 1.45E-02 1.30E-03 3.20E-03 AP 5
L5737-01 6/30/2003 GROSS BETA 1.90E-02 1.40E-03 3.30E-03 AP 5
L5793-01 7/14/2003 GROSS BETA 2.14E-02 1.40E-03 3.30E-03 AP 5
L5870-01 7/28/2003 GROSS BETA 2.01E-02 1.40E-03 3.40E-03 AP 5
L5958-01 8/11/2003 GROSS BETA 1.20E-02 1.20E-03 3.20E-03 AP 5
L6027-01 8/25/2003 GROSS BETA 2.19E-02 1.40E-03 3.20E-03 AP 5
L6121-01 9/8/2003 GROSS BETA 1.92E-02 1.00E-03 2.20E-03 AP 5
L6188-01 9/22/2003 GROSS BETA 2.23E-02 1.40E-03 3.30E-03 AP 5
L6277-01 10/6/2003 GROSS BETA 2.11E-02 1.30E-03 2.70E-03 AP 5
L6358-01 10/20/2003 GROSS BETA 2.53E-02 1.40E-03 2.60E-03 AP 5
L6450-01 11/3/2003 GROSS BETA 1.90E-02 1.40E-03 3.40E-03 AP 5
L6524-01 11/17/2003 GROSS BETA 2.12E-02 1.40E-03 3.20E-03 AP 5
L6654-01 12/15/2003 GROSS BETA 1.58E-02 1.10E-03 2.50E-03 AP 5
L6724-01 12/29/2003 GROSS BETA 2.07E-02 1.70E-03 4.30E-03 AP 5
L5295-01 3/24/2003 Be-7 9.00E-02 2.20E-02 5.50E-02 AP 5
L5295-01 3/24/2003 Co-58 5.00E-04 9.60E-04 3.90E-03 AP 5
L5295-01 3/24/2003 Co-60 1.90E-04 6.00E-04 2.50E-03 AP 5
L5295-01 3/24/2003 Cs-134
-2.50E-04 5.90E-04 2.60E-03 AP 5
L5295-01 3/24/2003 Cs-137 5.90E-04 6.60E-04 2.30E-03 AP 5
L5904-01 6/30/2003 Be-7 5.20E-02 2.10E-02 6.50E-02 AP 5
L5904-01 6/30/2003 Co-58
-1.00E-03 1.10E-03 5.10E-03 AP 5
L5904-01 6/30/2003 Co-60
-5.60E-04 6.00E-04 2.90E-03 AP 5
L5904-01 6/30/2003 Cs-134
-3.80E-04 5.50E-04 2.50E-03 AP 5
L5904-01 6/30/2003 Cs-137
-1.20E-04 4.90E-04 2.00E-03 AP 5
L6321-01 10/6/2003 Be-7 7.10E-02 1.70E-02 4.70E-02 AP 5
L6321-01 10/6/2003 Co-58 9.90E-04 9.80E-04 3.40E-03 AP 5
L6321-01 10/6/2003 Co-60
-1.08E-03 7.10E-04 3.50E-03 AP 5
L6321-01 10/6/2003 Cs-134
-2.40E-04 4.70E-04 2.20E-03 AP 5
L6321-01 10/6/2003 Cs-137
-1.20E-04 5.00E-04 2.10E-03 AP 5
L6810-01 12/29/2003 Be-7 7.30E-02 2.10E-02 5.90E-02 AP 5
L6810-01 12/29/2003 Co-58 3.00E-04 1.10E-03 4.60E-03 AP 5
L6810-01 12/29/2003 Co-60 2.00E-04 6.20E-04 2.60E-03 AP 5
L6810-01 12/29/2003 Cs-134
-2.60E-04 6.00E-04 2.70E-03 AP 5
L6810-01 12/29/2003 Cs-137 1.90E-04 6.10E-04 2.40E-03
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/m3) (pCi/m3) (pCi/m3)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-2 AIR PARTICULATE AP 6
L4665-02 1/13/2003 GROSS BETA 1.80E-02 1.40E-03 3.40E-03 AP 6
L4750-02 1/27/2003 GROSS BETA 2.50E-02 1.30E-03 2.40E-03 AP 6
L4853-02 2/10/2003 GROSS BETA 2.41E-02 1.30E-03 2.60E-03 AP 6
L4936-02 2/24/2003 GROSS BETA 1.83E-02 1.40E-03 3.50E-03 AP 6
L5068-02 3/10/2003 GROSS BETA 2.92E-02 1.50E-03 3.00E-03 AP 6
L5133-02 3/25/2003 GROSS BETA 1.99E-02 1.30E-03 3.20E-03 AP 6
L5233-02 4/7/2003 GROSS BETA 1.74E-02 1.40E-03 3.50E-03 AP 6
L5324-02 4/21/2003 GROSS BETA 2.22E-02 1.30E-03 2.60E-03 AP 6
L5416-02 5/5/2003 GROSS BETA 1.36E-02 1.10E-03 2.60E-03 AP 6
L5479-02 5/19/2003 GROSS BETA 8.04E-03 8.10E-04 2.10E-03 AP 6
L5565-02 6/2/2003 GROSS BETA 1.06E-02 9.40E-04 2.50E-03 AP 6
L5656-02 6/16/2003 GROSS BETA 1.25E-02 1.20E-03 3.20E-03 AP 6
L5737-02 6/30/2003 GROSS BETA 2.07E-02 1.40E-03 3.30E-03 AP 6
L5793-02 7/14/2003 GROSS BETA 2.49E-02 1.50E-03 3.30E-03 AP 6
L5870-02 7/28/2003 GROSS BETA 2.10E-02 1.40E-03 3.30E-03 AP 6
L5958-02 8/11/2003 GROSS BETA 1.22E-02 1.20E-03 3.10E-03 AP 6
L6027-02 8/25/2003 GROSS BETA 2.44E-02 1.40E-03 3.10E-03 AP 6
L6121-02 9/8/2003 GROSS BETA 2.17E-02 1.10E-03 2.20E-03 AP 6
L6188-02 9/22/2003 GROSS BETA 2.14E-02 1.40E-03 3.20E-03 AP 6
L6277-02 10/6/2003 GROSS BETA 1.91E-02 1.20E-03 2.70E-03 AP 6
L6358-02 10/20/2003 GROSS BETA 3.00E-02 1.40E-03 2.60E-03 AP 6
L6450-02 11/3/2003 GROSS BETA 2.17E-02 1.40E-03 3.30E-03 AP 6
L6524-02 11/17/2003 GROSS BETA 2.50E-02 1.40E-03 3.20E-03 AP 6
L6654-02 12/15/2003 GROSS BETA 1.53E-02 1.10E-03 2.50E-03 AP 6
L6724-02 12/29/2003 GROSS BETA 1.66E-02 1.40E-03 3.70E-03 AP 6
L5295-02 3/25/2003 Be-7 7.70E-02 2.10E-02 5.60E-02 AP 6
L5295-02 3/25/2003 Co-58
-2.10E-04 9.10E-04 4.10E-03 AP 6
L5295-02 3/25/2003 Co-60 1.41E-03 8.00E-04 2.40E-03 AP 6
L5295-02 3/25/2003 Cs-134 3.40E-04 6.60E-04 2.50E-03 AP 6
L5295-02 3/25/2003 Cs-137 5.70E-04 6.30E-04 2.30E-03 AP 6
L5904-02 6/30/2003 Be-7 7.40E-02 2.10E-02 5.80E-02 AP 6
L5904-02 6/30/2003 Co-58 1.50E-03 1.10E-03 3.50E-03 AP 6
L5904-02 6/30/2003 Co-60
-5.70E-04 6.00E-04 2.90E-03 AP 6
L5904-02 6/30/2003 Cs-134 6.10E-04 5.20E-04 1.80E-03 AP 6
L5904-02 6/30/2003 Cs-137
-1.40E-04 5.30E-04 2.20E-03 AP 6
L6321-02 10/6/2003 Be-7 1.09E-01 1.70E-02 3.60E-02 AP 6
L6321-02 10/6/2003 Co-58 3.90E-04 7.30E-04 2.90E-03 AP 6
L6321-02 10/6/2003 Co-60 1.51E-03 7.60E-04 2.20E-03 AP 6
L6321-02 10/6/2003 Cs-134 6.10E-04 5.50E-04 1.90E-03 AP 6
L6321-02 10/6/2003 Cs-137
-1.09E-03 5.90E-04 2.70E-03 AP 6
L6810-02 12/29/2003 Be-7 1.19E-01 2.10E-02 4.40E-02 AP 6
L6810-02 12/29/2003 Co-58 2.00E-04 1.00E-03 4.20E-03 AP 6
L6810-02 12/29/2003 Co-60 5.10E-04 3.60E-04 6.90E-04 AP 6
L6810-02 12/29/2003 Cs-134
-4.00E-04 6.70E-04 2.90E-03 AP 6
L6810-02 12/29/2003 Cs-137 7.00E-04 6.10E-04 2.10E-03
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/m3) (pCi/m3) (pCi/m3)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-3 AIR PARTICULATE AP 7
L4665-03 1/13/2003 GROSS BETA 1.81E-02 1.30E-03 3.30E-03 AP 7
L4750-03 1/27/2003 GROSS BETA 2.47E-02 1.30E-03 2.30E-03 AP 7
L4853-03 2/10/2003 GROSS BETA 2.53E-02 1.30E-03 2.50E-03 AP 7
L4936-03 2/24/2003 GROSS BETA 1.88E-02 1.30E-03 3.40E-03 AP 7
L5068-03 3/10/2003 GROSS BETA 2.80E-02 1.40E-03 2.90E-03 AP 7
L5133-03 3/24/2003 GROSS BETA 2.18E-02 1.40E-03 3.30E-03 AP 7
L5233-03 4/7/2003 GROSS BETA 1.76E-02 1.30E-03 3.10E-03 AP 7
L5324-03 4/21/2003 GROSS BETA 2.33E-02 1.20E-03 2.30E-03 AP 7
L5416-03 5/5/2003 GROSS BETA 1.63E-02 1.10E-03 2.50E-03 AP 7
L5479-03 5/19/2003 GROSS BETA 9.60E-03 8.00E-04 2.00E-03 AP 7
L5565-03 6/2/2003 GROSS BETA 1.07E-02 9.20E-04 2.40E-03 AP 7
L5656-03 6/16/2003 GROSS BETA 1.37E-02 1.20E-03 3.00E-03 AP 7
L5737-03 6/30/2003 GROSS BETA 1.88E-02 1.30E-03 3.20E-03 AP 7
L5793-03 7/14/2003 GROSS BETA 2.01E-02 1.30E-03 3.10E-03 AP 7
L5870-03 7/28/2003 GROSS BETA 2.21E-02 1.40E-03 3.20E-03 AP 7
L5958-03 8/11/2003 GROSS BETA 1.35E-02 1.20E-03 3.00E-03 AP 7
L6027-03 8/25/2003 GROSS BETA 2.21E-02 1.30E-03 2.90E-03 AP 7
L6121-03 9/8/2003 GROSS BETA 2.20E-02 1.10E-03 2.10E-03 AP 7
L6188-03 9/22/2003 GROSS BETA 2.20E-02 1.40E-03 3.10E-03 AP 7
L6277-03 10/6/2003 GROSS BETA 1.84E-02 1.20E-03 2.60E-03 AP 7
L6358-03 10/20/2003 GROSS BETA 2.84E-02 1.40E-03 2.40E-03 AP 7
L6450-03 11/3/2003 GROSS BETA 1.69E-02 1.30E-03 3.10E-03 AP 7
L6524-03 11/17/2003 GROSS BETA 2.34E-02 1.40E-03 3.00E-03 AP 7
L6654-03 12/15/2003 GROSS BETA 1.71E-02 1.10E-03 2.40E-03 AP 7
L6724-03 12/29/2003 GROSS BETA 2.00E-02 1.40E-03 3.50E-03 AP 7
L5295-03 3/24/2003 Be-7 1.14E-01 2.30E-02 5.20E-02 AP 7
L5295-03 3/24/2003 Co-58
-1.10E-03 1.20E-03 5.50E-03 AP 7
L5295-03 3/24/2003 Co-60
-9.00E-05 6.20E-04 2.70E-03 AP 7
L5295-03 3/24/2003 Cs-134
-4.20E-04 5.20E-04 2.40E-03 AP 7
L5295-03 3/24/2003 Cs-137
-1.70E-04 4.60E-04 2.00E-03 AP 7
L5904-03 6/30/2003 Be-7 7.80E-02 1.90E-02 4.80E-02 AP 7
L5904-03 6/30/2003 Co-58 8.20E-04 9.80E-04 3.60E-03 AP 7
L5904-03 6/30/2003 Co-60 4.20E-04 3.00E-04 5.70E-04 AP 7
L5904-03 6/30/2003 Cs-134
-4.00E-05 5.20E-04 2.20E-03 AP 7
L5904-03 6/30/2003 Cs-137 0.00E+00 5.20E-04 2.10E-03 AP 7
L6321-03 10/6/2003 Be-7 1.03E-01 1.70E-02 3.70E-02 AP 7
L6321-03 10/6/2003 Co-58
-2.50E-04 8.70E-04 3.60E-03 AP 7
L6321-03 10/6/2003 Co-60
-9.90E-04 5.80E-04 3.00E-03 AP 7
L6321-03 10/6/2003 Cs-134
-4.00E-05 5.20E-04 2.20E-03 AP 7
L6321-03 10/6/2003 Cs-137
-9.30E-04 6.20E-04 2.70E-03 AP 7
L6810-03 12/29/2003 Be-7 7.60E-02 1.90E-02 4.90E-02 AP 7
L6810-03 12/29/2003 Co-58
-1.30E-03 1.10E-03 5.00E-03 AP 7
L6810-03 12/29/2003 Co-60
-1.66E-03 7.60E-04 3.90E-03 AP 7
L6810-03 12/29/2003 Cs-134 8.30E-04 5.80E-04 1.90E-03 AP 7
L6810-03 12/29/2003 Cs-137 3.00E-05 5.40E-04 2.20E-03
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/m3) (pCi/m3) (pCi/m3)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-4 AIR PARTICULATE AP 9
L4665-04 1/13/2003 GROSS BETA 1.46E-02 1.30E-03 3.50E-03 AP 9
L4750-04 1/27/2003 GROSS BETA 2.11E-02 1.20E-03 2.40E-03 AP 9
L4853-04 2/10/2003 GROSS BETA 2.60E-02 1.40E-03 2.70E-03 AP 9
L4936-04 2/24/2003 GROSS BETA 1.97E-02 1.40E-03 3.60E-03 AP 9
L5068-04 3/10/2003 GROSS BETA 2.82E-02 1.60E-03 3.40E-03 AP 9
L5133-04 3/24/2003 GROSS BETA 2.05E-02 1.50E-03 3.70E-03 AP 9
L5233-04 4/7/2003 GROSS BETA 1.64E-02 1.40E-03 3.40E-03 AP 9
L5324-04 4/21/2003 GROSS BETA 1.70E-02 1.10E-03 2.30E-03 AP 9
L5416-04 5/5/2003 GROSS BETA 1.47E-02 1.30E-03 3.20E-03 AP 9
L5479-04 5/19/2003 GROSS BETA 8.41E-03 8.50E-04 2.20E-03 AP 9
L5565-04 6/2/2003 GROSS BETA 8.40E-03 9.40E-04 2.60E-03 AP 9
L5656-04 6/16/2003 GROSS BETA 1.16E-02 1.30E-03 3.40E-03 AP 9
L5737-04 6/30/2003 GROSS BETA 1.96E-02 1.50E-03 3.50E-03 AP 9
L5793-04 7/14/2003 GROSS BETA 2.18E-02 1.50E-03 3.50E-03 AP 9
L5870-04 7/28/2003 GROSS BETA 2.23E-02 1.50E-03 3.50E-03 AP 9
L5958-04 8/11/2003 GROSS BETA 1.27E-02 1.30E-03 3.30E-03 AP 9
L6027-04 8/25/2003 GROSS BETA 2.24E-02 1.50E-03 3.30E-03 AP 9
L6121-04 9/8/2003 GROSS BETA 2.03E-02 1.10E-03 2.40E-03 AP 9
L6188-04 9/22/2003 GROSS BETA 2.12E-02 1.50E-03 3.40E-03 AP 9
L6277-04 10/6/2003 GROSS BETA 2.08E-02 1.40E-03 2.90E-03 AP 9
L6358-04 10/20/2003 GROSS BETA 2.99E-02 1.60E-03 3.10E-03 AP 9
L6450-04 11/3/2003 GROSS BETA 2.17E-02 1.60E-03 4.10E-03 AP 9
L6524-04 11/17/2003 GROSS BETA 2.47E-02 1.70E-03 3.90E-03 AP 9
L6654-04 12/15/2003 GROSS BETA 2.19E-02 2.10E-03 5.00E-03 AP 9
L5295-04 3/24/2003 Be-7 8.90E-02 2.50E-02 6.80E-02 AP 9
L5295-04 3/24/2003 Co-58
-6.10E-04 8.80E-04 4.40E-03 AP 9
L5295-04 3/24/2003 Co-60 4.20E-04 7.70E-04 3.00E-03 AP 9
L5295-04 3/24/2003 Cs-134
-1.00E-04 5.00E-04 2.30E-03 AP 9
L5295-04 3/24/2003 Cs-137
-4.30E-04 6.40E-04 2.70E-03 AP 9
L5904-04 6/30/2003 Be-7 7.10E-02 2.20E-02 6.40E-02 AP 9
L5904-04 6/30/2003 Co-58
-5.00E-04 9.50E-04 4.40E-03 AP 9
L5904-04 6/30/2003 Co-60
-3.00E-05 3.60E-04 1.80E-03 AP 9
L5904-04 6/30/2003 Cs-134
-6.10E-04 4.80E-04 2.40E-03 AP 9
L5904-04 6/30/2003 Cs-137 4.40E-04 6.30E-04 2.30E-03 AP 9
L6321-04 10/6/2003 Be-7 9.60E-02 2.10E-02 4.80E-02 AP 9
L6321-04 10/6/2003 Co-58
-6.90E-04 4.90E-04 3.40E-03 AP 9
L6321-04 10/6/2003 Co-60 1.36E-03 6.80E-04 9.20E-04 AP 9
L6321-04 10/6/2003 Cs-134 6.30E-04 7.20E-04 2.70E-03 AP 9
L6321-04 10/6/2003 Cs-137
-1.40E-04 6.60E-04 2.80E-03 AP 9
L6810-04 12/15/2003 Be-7 7.00E-02 3.10E-02 9.40E-02 AP 9
L6810-04 12/15/2003 Co-58 2.80E-03 2.30E-03 7.70E-03 AP 9
L6810-04 12/15/2003 Co-60 4.10E-04 4.10E-04 1.10E-03 AP 9
L6810-04 12/15/2003 Cs-134
-1.50E-03 1.10E-03 5.20E-03 AP 9
L6810-04 12/15/2003 Cs-137
-2.19E-03 9.70E-04 4.70E-03
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/m3) (pCi/m3) (pCi/m3)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-5 AIR PARTICULATE AP 13 L4665-05 1/13/2003 GROSS BETA 1.88E-02 1.30E-03 3.20E-03 AP 13 L4750-05 1/27/2003 GROSS BETA 2.37E-02 1.20E-03 2.20E-03 AP 13 L4853-05 2/10/2003 GROSS BETA 2.59E-02 1.30E-03 2.40E-03 AP 13 L4936-05 2/24/2003 GROSS BETA 1.76E-02 1.30E-03 3.30E-03 AP 13 L5068-05 3/10/2003 GROSS BETA 2.91E-02 1.40E-03 2.90E-03 AP 13 L5133-05 3/24/2003 GROSS BETA 2.00E-02 1.30E-03 3.00E-03 AP 13 L5233-05 4/7/2003 GROSS BETA 1.77E-02 1.30E-03 3.20E-03 AP 13 L5324-05 4/21/2003 GROSS BETA 2.41E-02 1.20E-03 2.20E-03 AP 13 L5416-05 5/5/2003 GROSS BETA 1.55E-02 1.10E-03 2.40E-03 AP 13 L5479-05 5/19/2003 GROSS BETA 9.36E-03 7.80E-04 1.90E-03 AP 13 L5565-05 6/2/2003 GROSS BETA 1.12E-02 1.00E-03 2.70E-03 AP 13 L5656-05 6/16/2003 GROSS BETA 1.42E-02 1.20E-03 2.90E-03 AP 13 L5737-05 6/30/2003 GROSS BETA 1.74E-02 1.30E-03 3.10E-03 AP 13 L5793-05 7/14/2003 GROSS BETA 1.92E-02 1.30E-03 3.00E-03 AP 13 L5870-05 7/28/2003 GROSS BETA 2.07E-02 1.30E-03 3.00E-03 AP 13 L5958-05 8/11/2003 GROSS BETA 1.04E-02 1.10E-03 2.90E-03 AP 13 L6027-05 8/25/2003 GROSS BETA 2.41E-02 1.30E-03 2.90E-03 AP 13 L6121-05 9/8/2003 GROSS BETA 3.61E-02 7.00E-03 2.10E-02
- +
AP 13 L6188-05 9/22/2003 GROSS BETA 2.25E-02 1.60E-03 3.70E-03 AP 13 L6277-05 10/6/2003 GROSS BETA 2.29E-02 1.40E-03 2.80E-03 AP 13 L6358-05 10/20/2003 GROSS BETA 2.81E-02 1.40E-03 2.60E-03 AP 13 L6450-05 11/3/2003 GROSS BETA 2.11E-02 1.50E-03 3.50E-03 AP 13 L6524-05 11/17/2003 GROSS BETA 2.22E-02 1.40E-03 3.30E-03 AP 13 L6654-05 12/15/2003 GROSS BETA 1.55E-02 1.10E-03 2.50E-03 AP 13 L6724-05 12/29/2003 GROSS BETA 2.08E-02 1.50E-03 3.80E-03 AP 13 L5295-05 3/24/2003 Be-7 7.00E-02 2.10E-02 6.10E-02 AP 13 L5295-05 3/24/2003 Co-58
-2.80E-04 5.60E-04 3.00E-03 AP 13 L5295-05 3/24/2003 Co-60
-9.00E-05 6.00E-04 2.60E-03 AP 13 L5295-05 3/24/2003 Cs-134 6.40E-04 5.80E-04 2.00E-03 AP 13 L5295-05 3/24/2003 Cs-137 2.50E-04 5.60E-04 2.10E-03 AP 13 L5904-05 6/30/2003 Be-7 6.20E-02 2.10E-02 6.00E-02 AP 13 L5904-05 6/30/2003 Co-58 4.80E-04 9.10E-04 3.60E-03 AP 13 L5904-05 6/30/2003 Co-60 8.30E-04 4.20E-04 5.60E-04 AP 13 L5904-05 6/30/2003 Cs-134
-1.00E-04 3.40E-04 1.70E-03 AP 13 L5904-05 6/30/2003 Cs-137
-3.90E-04 4.50E-04 2.00E-03 AP 13 L6321-05 10/6/2003 Be-7 1.17E-01 2.00E-02 4.40E-02 AP 13 L6321-05 10/6/2003 Co-58
-8.80E-04 9.30E-04 4.30E-03 AP 13 L6321-05 10/6/2003 Co-60 9.40E-04 7.30E-04 2.50E-03 AP 13 L6321-05 10/6/2003 Cs-134
-2.20E-04 6.30E-04 2.70E-03 AP 13 L6321-05 10/6/2003 Cs-137 7.10E-04 5.50E-04 1.90E-03 AP 13 L6810-05 12/29/2003 Be-7 5.80E-02 1.80E-02 5.20E-02 AP 13 L6810-05 12/29/2003 Co-58 3.00E-04 1.20E-03 4.90E-03 AP 13 L6810-05 12/29/2003 Co-60
-3.60E-04 6.30E-04 3.00E-03 AP 13 L6810-05 12/29/2003 Cs-134
-1.17E-03 7.30E-04 3.50E-03 AP 13 L6810-05 12/29/2003 Cs-137 7.50E-04 5.80E-04 2.00E-03
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-6 FISH BONE FB HA L6445-02 10/28/2003 Sr-89
-1.23E+02 7.50E+01 2.70E+02 FB HA L6445-02 10/28/2003 Sr-90
-2.90E+01 7.70E+01 2.60E+02 FB WI L6445-01 10/21/2003 Sr-89 1.50E+02 1.30E+02 4.50E+02 FB WI L6445-01 10/21/2003 Sr-90
-2.00E+01 1.20E+02 3.90E+02
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-7 FISH FLESH FF HA L6445-02 10/28/2003 GROSS ALPHA 8.90E+01 6.50E+01 2.00E+02 FF HA L6445-02 10/28/2003 GROSS BETA 3.71E+03 8.60E+01 7.00E+01 FF HA L6445-02 10/28/2003 AcTh-228
-2.00E+00 1.10E+01 4.20E+01 FF HA L6445-02 10/28/2003 Ag-110m 1.70E+00 5.10E+00 1.90E+01 FF HA L6445-02 10/28/2003 Ba-140 8.70E+00 4.60E+00 1.30E+01 FF HA L6445-02 10/28/2003 Be-7 3.30E+01 3.10E+01 1.00E+02 FF HA L6445-02 10/28/2003 Ce-141 3.40E+00 5.80E+00 2.00E+01 FF HA L6445-02 10/28/2003 Ce-144 0.00E+00 1.70E+01 6.10E+01 FF HA L6445-02 10/28/2003 Co-57
-1.20E+00 2.20E+00 7.90E+00 FF HA L6445-02 10/28/2003 Co-58 1.20E+00 3.70E+00 1.40E+01 FF HA L6445-02 10/28/2003 Co-60
-7.00E+00 4.10E+00 1.80E+01 FF HA L6445-02 10/28/2003 Cs-134 3.20E+00 2.60E+00 8.90E+00 FF HA L6445-02 10/28/2003 Cs-137 1.38E+01 3.50E+00 8.50E+00 FF HA L6445-02 10/28/2003 Fe-59 9.00E+00 1.10E+01 3.70E+01 FF HA L6445-02 10/28/2003 H-3 1.00E+02 6.20E+02 1.80E+03 FF HA L6445-02 10/28/2003 I-131 1.00E+01 1.00E+01 3.40E+01 FF HA L6445-02 10/28/2003 K-40 2.75E+03 1.60E+02 1.90E+02 FF HA L6445-02 10/28/2003 La-140 1.00E+01 5.30E+00 1.50E+01 FF HA L6445-02 10/28/2003 Mn-54 3.40E+00 3.60E+00 1.20E+01 FF HA L6445-02 10/28/2003 Nb-95
-3.40E+00 3.70E+00 1.50E+01 FF HA L6445-02 10/28/2003 Ru-103
-1.60E+00 3.50E+00 1.30E+01 FF HA L6445-02 10/28/2003 Ru-106
-3.80E+01 2.90E+01 1.20E+02 FF HA L6445-02 10/28/2003 Sb-124 2.30E+00 5.00E+00 2.10E+01 FF HA L6445-02 10/28/2003 Zn-65
-1.23E+01 9.30E+00 3.70E+01 FF HA L6445-02 10/28/2003 Zr-95
-1.29E+01 6.50E+00 2.70E+01 FF WI L6445-01 10/21/2003 GROSS ALPHA
-7.30E+01 3.40E+01 1.40E+02 FF WI L6445-01 10/21/2003 GROSS BETA 2.97E+03 6.50E+01 5.30E+01 FF WI L6445-01 10/21/2003 AcTh-228
-7.00E+00 1.50E+01 5.70E+01 FF WI L6445-01 10/21/2003 Ag-110m 4.20E+00 4.80E+00 1.70E+01 FF WI L6445-01 10/21/2003 Ba-140
-2.50E+00 8.30E+00 3.50E+01 FF WI L6445-01 10/21/2003 Be-7
-3.50E+01 3.10E+01 1.20E+02 FF WI L6445-01 10/21/2003 Ce-141 6.20E+00 7.30E+00 2.50E+01 FF WI L6445-01 10/21/2003 Ce-144
-8.00E+00 1.90E+01 6.90E+01 FF WI L6445-01 10/21/2003 Co-57
-1.00E-01 2.40E+00 8.60E+00 FF WI L6445-01 10/21/2003 Co-58
-1.30E+00 3.50E+00 1.40E+01 FF WI L6445-01 10/21/2003 Co-60 1.50E+00 3.20E+00 1.20E+01 FF WI L6445-01 10/21/2003 Cs-134 1.90E+00 3.50E+00 1.30E+01 FF WI L6445-01 10/21/2003 Cs-137 4.80E+00 3.70E+00 1.30E+01 FF WI L6445-01 10/21/2003 Fe-59
-1.70E+01 1.20E+01 5.10E+01 FF WI L6445-01 10/21/2003 H-3
-2.50E+02 6.30E+02 1.90E+03 FF WI L6445-01 10/21/2003 I-131 4.00E+00 1.70E+01 6.10E+01 FF WI L6445-01 10/21/2003 K-40 2.53E+03 1.50E+02 1.60E+02 FF WI L6445-01 10/21/2003 La-140
-2.90E+00 9.50E+00 4.00E+01 FF WI L6445-01 10/21/2003 Mn-54
-2.30E+00 3.20E+00 1.30E+01 FF WI L6445-01 10/21/2003 Nb-95
-4.60E+00 4.50E+00 1.80E+01 FF WI L6445-01 10/21/2003 Ru-103 2.60E+00 4.00E+00 1.40E+01 FF WI L6445-01 10/21/2003 Ru-106
-2.00E+00 2.70E+01 1.00E+02 FF WI L6445-01 10/21/2003 Sb-124 2.40E+00 8.00E+00 3.20E+01 FF WI L6445-01 10/21/2003 Zn-65 2.30E+01 1.70E+01 5.70E+01 FF 0
L6445-01 10/21/2003 Zr-95 1.10E+00 6.00E+00 2.20E+01
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-8 FISH FH 26 L5640-04 6/9/2003 Ag-110m
-7.00E+00 1.50E+01 6.10E+01 FH 26 L5640-04 6/9/2003 Ba-140
-1.60E+01 2.80E+01 1.20E+02 FH 26 L5640-04 6/9/2003 Be-7
-3.30E+01 8.40E+01 3.30E+02 FH 26 L5640-04 6/9/2003 Ce-141
-1.30E+01 1.50E+01 5.60E+01 FH 26 L5640-04 6/9/2003 Ce-144
-6.10E+01 4.70E+01 1.80E+02 FH 26 L5640-04 6/9/2003 Co-57 1.42E+01 6.50E+00 2.10E+01 FH 26 L5640-04 6/9/2003 Co-58 6.00E+00 1.10E+01 4.00E+01 FH 26 L5640-04 6/9/2003 Co-60
-2.00E+00 1.10E+01 4.60E+01 FH 26 L5640-04 6/9/2003 Cs-134 1.00E+00 1.20E+01 4.60E+01 FH 26 L5640-04 6/9/2003 Cs-137
-1.10E+01 1.10E+01 4.70E+01 FH 26 L5640-04 6/9/2003 Fe-59 0.00E+00 2.60E+01 1.00E+02 FH 26 L5640-04 6/9/2003 I-131
-4.20E+01 2.90E+01 1.20E+02 FH 26 L5640-04 6/9/2003 K-40 3.43E+03 3.70E+02 5.10E+02 FH 26 L5640-04 6/9/2003 Mn-54 2.10E+00 8.50E+00 3.30E+01 FH 26 L5640-04 6/9/2003 Ru-103
-1.90E+01 1.00E+01 4.50E+01 FH 26 L5640-04 6/9/2003 Ru-106
-9.10E+01 9.00E+01 3.80E+02 FH 26 L5640-04 6/9/2003 Sb-124
-5.20E+01 2.30E+01 1.40E+02 FH 26 L5640-04 6/9/2003 Zn-65 1.20E+01 2.60E+01 9.80E+01 FH 26 L5640-04 6/9/2003 Zr-95 1.00E+00 1.80E+01 7.20E+01 FH 26 L5640-01 6/11/2003 Ag-110m 1.10E+01 1.10E+01 3.90E+01 FH 26 L5640-01 6/11/2003 Ba-140 2.00E+01 1.20E+01 3.80E+01 FH 26 L5640-01 6/11/2003 Be-7 3.30E+01 7.90E+01 2.80E+02 FH 26 L5640-01 6/11/2003 Ce-141
-1.10E+01 1.40E+01 5.00E+01 FH 26 L5640-01 6/11/2003 Ce-144 7.20E+01 4.70E+01 1.50E+02 FH 26 L5640-01 6/11/2003 Co-57 6.90E+00 6.10E+00 2.00E+01 FH 26 L5640-01 6/11/2003 Co-58
-6.50E+00 9.10E+00 3.60E+01 FH 26 L5640-01 6/11/2003 Co-60 2.10E+00 6.90E+00 2.70E+01 FH 26 L5640-01 6/11/2003 Cs-134 2.01E+01 9.20E+00 2.80E+01 FH 26 L5640-01 6/11/2003 Cs-137 7.40E+00 9.80E+00 3.40E+01 FH 26 L5640-01 6/11/2003 Fe-59 2.50E+01 2.20E+01 7.40E+01 FH 26 L5640-01 6/11/2003 I-131 3.50E+01 2.00E+01 6.50E+01 FH 26 L5640-01 6/11/2003 K-40 2.02E+03 2.30E+02 4.00E+02 FH 26 L5640-01 6/11/2003 Mn-54 1.50E+00 8.40E+00 3.10E+01 FH 26 L5640-01 6/11/2003 Ru-103
-4.00E+00 1.00E+01 3.80E+01 FH 26 L5640-01 6/11/2003 Ru-106
-8.00E+00 9.10E+01 3.30E+02 FH 26 L5640-01 6/11/2003 Sb-124 6.00E+00 2.10E+01 8.10E+01 FH 26 L5640-01 6/11/2003 Zn-65 3.50E+01 2.30E+01 7.80E+01 FH 26 L5640-01 6/11/2003 Zr-95 0.00E+00 1.60E+01 6.00E+01
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-9 FISH FH 26 L6182-03 9/16/2003 Ag-110m
-7.00E+00 1.40E+01 5.90E+01 FH 26 L6182-03 9/16/2003 Ba-140
-3.50E+01 3.50E+01 1.90E+02 FH 26 L6182-03 9/16/2003 Be-7
-6.00E+01 1.00E+02 4.00E+02 FH 26 L6182-03 9/16/2003 Ce-141
-1.60E+01 2.00E+01 7.30E+01 FH 26 L6182-03 9/16/2003 Ce-144 2.70E+01 5.10E+01 1.80E+02 FH 26 L6182-03 9/16/2003 Co-57
-1.70E+00 6.40E+00 2.30E+01 FH 26 L6182-03 9/16/2003 Co-58
-2.30E+01 1.40E+01 6.00E+01 FH 26 L6182-03 9/16/2003 Co-60
-3.00E+00 1.30E+01 5.20E+01 FH 26 L6182-03 9/16/2003 Cs-134
-1.50E+01 1.20E+01 5.20E+01 FH 26 L6182-03 9/16/2003 Cs-137 9.00E+00 1.20E+01 4.10E+01 FH 26 L6182-03 9/16/2003 Fe-59 3.90E+01 5.00E+01 1.80E+02 FH 26 L6182-03 9/16/2003 I-131
-7.00E+01 1.20E+02 4.50E+02 FH 26 L6182-03 9/16/2003 K-40 2.22E+03 3.10E+02 5.20E+02 FH 26 L6182-03 9/16/2003 Mn-54 3.00E+00 1.10E+01 4.00E+01 FH 26 L6182-03 9/16/2003 Ru-103 2.10E+01 1.50E+01 5.00E+01 FH 26 L6182-03 9/16/2003 Ru-106
-1.80E+02 1.10E+02 4.60E+02 FH 26 L6182-03 9/16/2003 Sb-124 3.60E+01 3.60E+01 1.30E+02 FH 26 L6182-03 9/16/2003 Zn-65
-6.20E+01 3.20E+01 1.40E+02 FH 26 L6182-03 9/16/2003 Zr-95
-1.20E+01 2.20E+01 8.90E+01 FH 26 L6182-06 9/16/2003 Ag-110m
-4.50E+01 2.50E+01 1.10E+02 FH 26 L6182-06 9/16/2003 Ba-140 4.70E+01 5.80E+01 2.20E+02 FH 26 L6182-06 9/16/2003 Be-7
-2.60E+02 1.60E+02 6.70E+02 FH 26 L6182-06 9/16/2003 Ce-141 2.00E+00 2.60E+01 9.50E+01 FH 26 L6182-06 9/16/2003 Ce-144
-9.00E+00 6.90E+01 2.50E+02 FH 26 L6182-06 9/16/2003 Co-57 3.00E-01 8.60E+00 3.10E+01 FH 26 L6182-06 9/16/2003 Co-58 2.10E+01 1.80E+01 6.10E+01 FH 26 L6182-06 9/16/2003 Co-60
-6.00E+00 1.10E+01 5.40E+01 FH 26 L6182-06 9/16/2003 Cs-134 1.10E+01 1.50E+01 5.40E+01 FH 26 L6182-06 9/16/2003 Cs-137 3.10E+01 1.60E+01 4.80E+01 FH 26 L6182-06 9/16/2003 Fe-59
-1.40E+01 6.50E+01 2.70E+02 FH 26 L6182-06 9/16/2003 I-131 1.00E+02 1.50E+02 5.30E+02 FH 26 L6182-06 9/16/2003 K-40 2.18E+03 3.70E+02 7.50E+02 FH 26 L6182-06 9/16/2003 Mn-54 0.00E+00 1.50E+01 5.90E+01 FH 26 L6182-06 9/16/2003 Ru-103 0.00E+00 1.90E+01 7.40E+01 FH 26 L6182-06 9/16/2003 Ru-106
-4.00E+01 1.30E+02 5.20E+02 FH 26 L6182-06 9/16/2003 Sb-124
-1.60E+01 2.80E+01 1.50E+02 FH 26 L6182-06 9/16/2003 Zn-65 0.00E+00 3.00E+01 1.20E+02 FH 26 L6182-06 9/16/2003 Zr-95 1.30E+01 2.50E+01 9.50E+01
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-10 FISH FH 26 L6183-03 9/16/2003 Ag-110m 0.00E+00 1.80E+01 7.20E+01 FH 26 L6183-03 9/16/2003 Ba-140
-2.40E+01 7.30E+01 3.20E+02 FH 26 L6183-03 9/16/2003 Be-7
-3.20E+02 1.50E+02 6.60E+02 FH 26 L6183-03 9/16/2003 Ce-141
-5.50E+01 2.60E+01 1.10E+02 FH 26 L6183-03 9/16/2003 Ce-144
-7.20E+01 6.20E+01 2.40E+02 FH 26 L6183-03 9/16/2003 Co-57 1.59E+01 9.10E+00 3.00E+01 FH 26 L6183-03 9/16/2003 Co-58 2.40E+01 1.60E+01 5.20E+01 FH 26 L6183-03 9/16/2003 Co-60
-3.40E+01 1.70E+01 8.30E+01 FH 26 L6183-03 9/16/2003 Cs-134
-1.10E+01 1.30E+01 5.80E+01 FH 26 L6183-03 9/16/2003 Cs-137 2.40E+01 1.20E+01 3.80E+01 FH 26 L6183-03 9/16/2003 Fe-59
-8.00E+00 5.10E+01 2.20E+02 FH 26 L6183-03 9/16/2003 I-131 2.00E+02 1.30E+02 4.30E+02 FH 26 L6183-03 9/16/2003 K-40 1.26E+03 3.00E+02 6.70E+02 FH 26 L6183-03 9/16/2003 Mn-54 2.80E+01 1.40E+01 4.20E+01 FH 26 L6183-03 9/16/2003 Ru-103 4.00E+00 1.90E+01 7.10E+01 FH 26 L6183-03 9/16/2003 Ru-106 1.00E+02 1.40E+02 5.10E+02 FH 26 L6183-03 9/16/2003 Sb-124
-1.70E+01 4.40E+01 2.00E+02 FH 26 L6183-03 9/16/2003 Zn-65
-1.80E+01 4.00E+01 1.60E+02 FH 26 L6183-03 9/16/2003 Zr-95
-1.40E+01 2.70E+01 1.20E+02 FH 26 L6183-06 9/16/2003 Ag-110m 7.00E+00 1.50E+01 5.40E+01 FH 26 L6183-06 9/16/2003 Ba-140 0.00E+00 3.90E+01 1.60E+02 FH 26 L6183-06 9/16/2003 Be-7 1.40E+01 8.50E+01 3.10E+02 FH 26 L6183-06 9/16/2003 Ce-141
-7.00E+00 1.70E+01 6.00E+01 FH 26 L6183-06 9/16/2003 Ce-144 1.50E+01 4.00E+01 1.40E+02 FH 26 L6183-06 9/16/2003 Co-57
-3.30E+00 5.30E+00 1.90E+01 FH 26 L6183-06 9/16/2003 Co-58 9.00E+00 1.20E+01 4.10E+01 FH 26 L6183-06 9/16/2003 Co-60 8.20E+00 9.50E+00 3.40E+01 FH 26 L6183-06 9/16/2003 Cs-134 0.00E+00 9.40E+00 3.60E+01 FH 26 L6183-06 9/16/2003 Cs-137
-8.00E+00 1.00E+01 4.00E+01 FH 26 L6183-06 9/16/2003 Fe-59 7.00E+00 4.00E+01 1.50E+02 FH 26 L6183-06 9/16/2003 I-131 7.00E+01 9.20E+01 3.20E+02 FH 26 L6183-06 9/16/2003 K-40 9.20E+02 2.00E+02 4.90E+02 FH 26 L6183-06 9/16/2003 Mn-54
-2.03E+01 8.80E+00 3.90E+01 FH 26 L6183-06 9/16/2003 Ru-103 6.00E+00 1.10E+01 4.10E+01 FH 26 L6183-06 9/16/2003 Ru-106 9.00E+00 7.30E+01 2.70E+02 FH 26 L6183-06 9/16/2003 Sb-124
-3.40E+01 2.70E+01 1.30E+02 FH 26 L6183-06 9/16/2003 Zn-65
-4.40E+01 2.10E+01 9.60E+01 FH 26 L6183-06 9/16/2003 Zr-95 2.40E+01 1.90E+01 6.30E+01
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-11 FISH FH 29 L5640-02 6/11/2003 Ag-110m
-1.70E+01 1.20E+01 4.90E+01 FH 29 L5640-02 6/11/2003 Ba-140 2.60E+01 1.60E+01 5.00E+01 FH 29 L5640-02 6/11/2003 Be-7
-1.04E+02 8.40E+01 3.30E+02 FH 29 L5640-02 6/11/2003 Ce-141 9.00E+00 1.40E+01 4.80E+01 FH 29 L5640-02 6/11/2003 Ce-144 7.70E+01 4.00E+01 1.30E+02 FH 29 L5640-02 6/11/2003 Co-57
-4.30E+00 6.10E+00 2.20E+01 FH 29 L5640-02 6/11/2003 Co-58
-4.70E+00 7.50E+00 3.00E+01 FH 29 L5640-02 6/11/2003 Co-60
-8.00E+00 9.00E+00 3.80E+01 FH 29 L5640-02 6/11/2003 Cs-134 0.00E+00 9.10E+00 3.40E+01 FH 29 L5640-02 6/11/2003 Cs-137 3.80E+01 1.30E+01 4.10E+01 FH 29 L5640-02 6/11/2003 Fe-59
-1.70E+01 1.90E+01 7.70E+01 FH 29 L5640-02 6/11/2003 I-131
-1.30E+01 2.40E+01 8.80E+01 FH 29 L5640-02 6/11/2003 K-40 3.40E+03 2.80E+02 3.70E+02 FH 29 L5640-02 6/11/2003 Mn-54 1.16E+01 9.10E+00 3.10E+01 FH 29 L5640-02 6/11/2003 Ru-103
-2.00E-01 9.40E+00 3.50E+01 FH 29 L5640-02 6/11/2003 Ru-106 8.30E+01 6.30E+01 2.10E+02 FH 29 L5640-02 6/11/2003 Sb-124
-8.00E+00 1.60E+01 7.10E+01 FH 29 L5640-02 6/11/2003 Zn-65
-1.50E+01 2.20E+01 8.60E+01 FH 29 L5640-02 6/11/2003 Zr-95
-1.90E+01 1.60E+01 6.60E+01 FH 29 L5640-05 6/11/2003 Ag-110m
-1.60E+01 1.30E+01 5.30E+01 FH 29 L5640-05 6/11/2003 Ba-140
-4.00E+00 1.50E+01 6.30E+01 FH 29 L5640-05 6/11/2003 Be-7 7.80E+01 7.80E+01 2.70E+02 FH 29 L5640-05 6/11/2003 Ce-141
-4.10E+01 1.60E+01 6.30E+01 FH 29 L5640-05 6/11/2003 Ce-144 7.00E+00 5.30E+01 1.90E+02 FH 29 L5640-05 6/11/2003 Co-57 4.10E+00 6.10E+00 2.10E+01 FH 29 L5640-05 6/11/2003 Co-58 0.00E+00 1.10E+01 3.90E+01 FH 29 L5640-05 6/11/2003 Co-60
-9.00E+00 1.30E+01 5.10E+01 FH 29 L5640-05 6/11/2003 Cs-134
-1.40E+01 1.10E+01 4.50E+01 FH 29 L5640-05 6/11/2003 Cs-137 4.00E+00 1.10E+01 3.90E+01 FH 29 L5640-05 6/11/2003 Fe-59 4.30E+01 2.20E+01 6.70E+01 FH 29 L5640-05 6/11/2003 I-131
-6.00E+00 2.50E+01 9.10E+01 FH 29 L5640-05 6/11/2003 K-40 2.88E+03 2.70E+02 4.00E+02 FH 29 L5640-05 6/11/2003 Mn-54
-1.39E+01 9.10E+00 3.80E+01 FH 29 L5640-05 6/11/2003 Ru-103
-9.00E+00 1.10E+01 4.20E+01 FH 29 L5640-05 6/11/2003 Ru-106
-1.20E+02 8.40E+01 3.40E+02 FH 29 L5640-05 6/11/2003 Sb-124 3.00E+01 2.40E+01 8.40E+01 FH 29 L5640-05 6/11/2003 Zn-65 4.20E+01 4.10E+01 1.40E+02 FH 29 L5640-05 6/11/2003 Zr-95
-9.00E+00 1.60E+01 6.30E+01
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-12 FISH FH 29 L6182-02 9/16/2003 Ag-110m
-3.00E+00 1.40E+01 5.50E+01 FH 29 L6182-02 9/16/2003 Ba-140
-3.50E+01 5.50E+01 2.40E+02 FH 29 L6182-02 9/16/2003 Be-7
-6.00E+01 1.10E+02 4.20E+02 FH 29 L6182-02 9/16/2003 Ce-141 2.00E+00 1.80E+01 6.40E+01 FH 29 L6182-02 9/16/2003 Ce-144
-6.50E+01 3.90E+01 1.60E+02 FH 29 L6182-02 9/16/2003 Co-57
-6.10E+00 4.40E+00 1.80E+01 FH 29 L6182-02 9/16/2003 Co-58 2.40E+01 1.20E+01 3.70E+01 FH 29 L6182-02 9/16/2003 Co-60 2.00E+00 1.10E+01 4.30E+01 FH 29 L6182-02 9/16/2003 Cs-134 8.00E+00 1.10E+01 3.90E+01 FH 29 L6182-02 9/16/2003 Cs-137 2.30E+01 1.20E+01 3.90E+01 FH 29 L6182-02 9/16/2003 Fe-59 6.60E+01 4.20E+01 1.40E+02 FH 29 L6182-02 9/16/2003 I-131 2.40E+01 9.20E+01 3.40E+02 FH 29 L6182-02 9/16/2003 K-40 1.77E+03 3.00E+02 6.40E+02 FH 29 L6182-02 9/16/2003 Mn-54
-3.00E+00 1.10E+01 4.30E+01 FH 29 L6182-02 9/16/2003 Ru-103
-5.00E+00 1.40E+01 5.50E+01 FH 29 L6182-02 9/16/2003 Ru-106 0.00E+00 8.10E+01 3.10E+02 FH 29 L6182-02 9/16/2003 Sb-124 2.40E+01 1.70E+01 3.20E+01 FH 29 L6182-02 9/16/2003 Zn-65 3.00E+01 2.80E+01 9.60E+01 FH 29 L6182-02 9/16/2003 Zr-95
-2.60E+01 2.60E+01 1.10E+02 FH 29 L6182-05 9/16/2003 Ag-110m
-8.00E+00 1.20E+01 4.70E+01 FH 29 L6182-05 9/16/2003 Ba-140
-3.70E+01 3.80E+01 1.70E+02 FH 29 L6182-05 9/16/2003 Be-7
-1.90E+02 1.10E+02 4.20E+02 FH 29 L6182-05 9/16/2003 Ce-141 3.00E+00 1.90E+01 6.70E+01 FH 29 L6182-05 9/16/2003 Ce-144 5.60E+01 4.70E+01 1.60E+02 FH 29 L6182-05 9/16/2003 Co-57 1.60E+00 5.60E+00 2.00E+01 FH 29 L6182-05 9/16/2003 Co-58 4.00E+00 1.00E+01 3.80E+01 FH 29 L6182-05 9/16/2003 Co-60
-5.90E+00 7.60E+00 3.30E+01 FH 29 L6182-05 9/16/2003 Cs-134 2.21E+01 8.10E+00 2.20E+01 FH 29 L6182-05 9/16/2003 Cs-137 4.50E+01 1.20E+01 3.50E+01 FH 29 L6182-05 9/16/2003 Fe-59
-3.40E+01 3.00E+01 1.30E+02 FH 29 L6182-05 9/16/2003 I-131
-3.00E+01 1.10E+02 4.00E+02 FH 29 L6182-05 9/16/2003 K-40 2.23E+03 2.40E+02 4.70E+02 FH 29 L6182-05 9/16/2003 Mn-54
-1.02E+01 9.80E+00 3.80E+01 FH 29 L6182-05 9/16/2003 Ru-103 3.00E+00 1.10E+01 4.00E+01 FH 29 L6182-05 9/16/2003 Ru-106 2.48E+02 9.20E+01 2.80E+02 FH 29 L6182-05 9/16/2003 Sb-124 3.10E+01 2.20E+01 7.50E+01 FH 29 L6182-05 9/16/2003 Zn-65
-3.60E+01 2.40E+01 9.80E+01 FH 29 L6182-05 9/16/2003 Zr-95 1.90E+01 1.80E+01 6.10E+01
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-13 FISH FH 29 L6183-02 9/16/2003 Ag-110m 1.50E+01 1.50E+01 5.30E+01 FH 29 L6183-02 9/16/2003 Ba-140 3.20E+01 4.40E+01 1.70E+02 FH 29 L6183-02 9/16/2003 Be-7
-2.00E+01 1.20E+02 4.70E+02 FH 29 L6183-02 9/16/2003 Ce-141
-2.60E+01 2.80E+01 1.10E+02 FH 29 L6183-02 9/16/2003 Ce-144
-1.50E+01 6.70E+01 2.40E+02 FH 29 L6183-02 9/16/2003 Co-57
-7.30E+00 8.40E+00 3.20E+01 FH 29 L6183-02 9/16/2003 Co-58 6.00E+00 1.40E+01 5.30E+01 FH 29 L6183-02 9/16/2003 Co-60
-7.00E+00 1.10E+01 4.90E+01 FH 29 L6183-02 9/16/2003 Cs-134 2.30E+01 1.20E+01 3.70E+01 FH 29 L6183-02 9/16/2003 Cs-137
-7.00E+00 1.50E+01 5.60E+01 FH 29 L6183-02 9/16/2003 Fe-59 4.90E+01 4.90E+01 1.70E+02 FH 29 L6183-02 9/16/2003 I-131
-6.00E+01 1.50E+02 5.70E+02 FH 29 L6183-02 9/16/2003 K-40 2.33E+03 3.40E+02 6.90E+02 FH 29 L6183-02 9/16/2003 Mn-54
-8.00E+00 1.10E+01 4.70E+01 FH 29 L6183-02 9/16/2003 Ru-103
-1.00E+00 1.50E+01 5.70E+01 FH 29 L6183-02 9/16/2003 Ru-106
-1.30E+02 1.10E+02 4.60E+02 FH 29 L6183-02 9/16/2003 Sb-124
-4.30E+01 4.10E+01 1.90E+02 FH 29 L6183-02 9/16/2003 Zn-65
-6.20E+01 3.00E+01 1.40E+02 FH 29 L6183-02 9/16/2003 Zr-95
-1.10E+01 2.60E+01 1.10E+02 FH 29 L6183-05 9/16/2003 Ag-110m 2.10E+01 1.20E+01 3.90E+01 FH 29 L6183-05 9/16/2003 Ba-140 1.00E+01 3.90E+01 1.50E+02 FH 29 L6183-05 9/16/2003 Be-7 1.20E+01 9.00E+01 3.30E+02 FH 29 L6183-05 9/16/2003 Ce-141
-5.00E+00 1.70E+01 6.20E+01 FH 29 L6183-05 9/16/2003 Ce-144
-6.00E+01 4.40E+01 1.60E+02 FH 29 L6183-05 9/16/2003 Co-57 6.10E+00 5.50E+00 1.80E+01 FH 29 L6183-05 9/16/2003 Co-58
-5.00E+00 1.10E+01 4.10E+01 FH 29 L6183-05 9/16/2003 Co-60 0.00E+00 8.60E+00 3.40E+01 FH 29 L6183-05 9/16/2003 Cs-134 5.00E+00 6.80E+00 2.50E+01 FH 29 L6183-05 9/16/2003 Cs-137
-6.70E+00 9.90E+00 3.80E+01 FH 29 L6183-05 9/16/2003 Fe-59 5.00E+00 3.40E+01 1.30E+02 FH 29 L6183-05 9/16/2003 I-131
-5.30E+01 9.40E+01 3.50E+02 FH 29 L6183-05 9/16/2003 K-40 1.79E+03 2.20E+02 4.10E+02 FH 29 L6183-05 9/16/2003 Mn-54
-4.30E+00 8.40E+00 3.30E+01 FH 29 L6183-05 9/16/2003 Ru-103
-1.80E+01 1.20E+01 4.70E+01 FH 29 L6183-05 9/16/2003 Ru-106
-1.50E+01 9.10E+01 3.30E+02 FH 29 L6183-05 9/16/2003 Sb-124 2.70E+01 2.30E+01 8.10E+01 FH 29 L6183-05 9/16/2003 Zn-65 7.00E+00 2.00E+01 7.30E+01 FH 29 L6183-05 9/16/2003 Zr-95
-2.30E+01 1.60E+01 6.70E+01
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-14 FISH FH 30 L5640-06 6/10/2003 Ag-110m
-1.01E+01 9.70E+00 4.10E+01 FH 30 L5640-06 6/10/2003 Ba-140
-1.50E+01 1.40E+01 6.50E+01 FH 30 L5640-06 6/10/2003 Be-7
-8.20E+01 7.40E+01 2.90E+02 FH 30 L5640-06 6/10/2003 Ce-141 0.00E+00 1.30E+01 4.60E+01 FH 30 L5640-06 6/10/2003 Ce-144
-8.00E+00 4.40E+01 1.60E+02 FH 30 L5640-06 6/10/2003 Co-57
-3.70E+00 5.80E+00 2.10E+01 FH 30 L5640-06 6/10/2003 Co-58
-1.21E+01 8.30E+00 3.50E+01 FH 30 L5640-06 6/10/2003 Co-60
-2.10E+01 1.00E+01 4.40E+01 FH 30 L5640-06 6/10/2003 Cs-134 3.10E+00 7.90E+00 2.90E+01 FH 30 L5640-06 6/10/2003 Cs-137 1.15E+01 8.40E+00 2.80E+01 FH 30 L5640-06 6/10/2003 Fe-59 9.00E+00 2.00E+01 7.30E+01 FH 30 L5640-06 6/10/2003 I-131
-3.30E+01 2.20E+01 8.70E+01 FH 30 L5640-06 6/10/2003 K-40 2.79E+03 2.60E+02 4.30E+02 FH 30 L5640-06 6/10/2003 Mn-54 5.60E+00 7.10E+00 2.50E+01 FH 30 L5640-06 6/10/2003 Ru-103
-6.00E+00 9.50E+00 3.60E+01 FH 30 L5640-06 6/10/2003 Ru-106 4.60E+01 7.60E+01 2.70E+02 FH 30 L5640-06 6/10/2003 Sb-124 2.50E+01 2.00E+01 6.90E+01 FH 30 L5640-06 6/10/2003 Zn-65
-2.10E+01 2.00E+01 8.10E+01 FH 30 L5640-06 6/10/2003 Zr-95
-3.00E+00 1.40E+01 5.30E+01 FH 30 L5640-03 6/11/2003 Ag-110m
-1.20E+01 1.70E+01 6.60E+01 FH 30 L5640-03 6/11/2003 Ba-140
-1.80E+01 2.00E+01 9.10E+01 FH 30 L5640-03 6/11/2003 Be-7
-7.30E+01 8.10E+01 3.30E+02 FH 30 L5640-03 6/11/2003 Ce-141
-8.00E+00 1.50E+01 5.60E+01 FH 30 L5640-03 6/11/2003 Ce-144
-1.60E+01 5.30E+01 1.90E+02 FH 30 L5640-03 6/11/2003 Co-57
-2.00E+00 6.30E+00 2.30E+01 FH 30 L5640-03 6/11/2003 Co-58 9.50E+00 9.90E+00 3.50E+01 FH 30 L5640-03 6/11/2003 Co-60 7.00E+00 1.10E+01 4.20E+01 FH 30 L5640-03 6/11/2003 Cs-134 1.10E+01 1.20E+01 4.00E+01 FH 30 L5640-03 6/11/2003 Cs-137
-5.00E+00 1.40E+01 5.30E+01 FH 30 L5640-03 6/11/2003 Fe-59
-1.60E+01 2.50E+01 1.00E+02 FH 30 L5640-03 6/11/2003 I-131
-1.10E+01 2.60E+01 9.80E+01 FH 30 L5640-03 6/11/2003 K-40 3.03E+03 3.30E+02 5.40E+02 FH 30 L5640-03 6/11/2003 Mn-54 0.00E+00 1.20E+01 4.40E+01 FH 30 L5640-03 6/11/2003 Ru-103 2.00E+01 1.10E+01 3.50E+01 FH 30 L5640-03 6/11/2003 Ru-106 1.36E+02 7.60E+01 2.40E+02 FH 30 L5640-03 6/11/2003 Sb-124
-3.40E+01 2.40E+01 1.20E+02 FH 30 L5640-03 6/11/2003 Zn-65
-5.00E+00 2.30E+01 9.10E+01 FH 30 L5640-03 6/11/2003 Zr-95 3.50E+01 1.90E+01 5.90E+01
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-15 FISH FH 30 L6182-01 9/17/2003 Ag-110m
-6.00E+00 1.50E+01 5.90E+01 FH 30 L6182-01 9/17/2003 Ba-140 2.70E+01 3.90E+01 1.50E+02 FH 30 L6182-01 9/17/2003 Be-7 7.00E+01 1.10E+02 3.80E+02 FH 30 L6182-01 9/17/2003 Ce-141
-8.00E+00 2.20E+01 7.80E+01 FH 30 L6182-01 9/17/2003 Ce-144 1.70E+01 5.20E+01 1.80E+02 FH 30 L6182-01 9/17/2003 Co-57 8.00E-01 6.50E+00 2.30E+01 FH 30 L6182-01 9/17/2003 Co-58 4.00E+00 1.20E+01 4.30E+01 FH 30 L6182-01 9/17/2003 Co-60 1.00E+01 1.00E+01 3.70E+01 FH 30 L6182-01 9/17/2003 Cs-134
-7.00E+00 1.10E+01 4.40E+01 FH 30 L6182-01 9/17/2003 Cs-137 2.20E+01 1.30E+01 4.20E+01 FH 30 L6182-01 9/17/2003 Fe-59 3.20E+01 4.20E+01 1.50E+02 FH 30 L6182-01 9/17/2003 I-131
-4.00E+01 1.00E+02 3.80E+02 FH 30 L6182-01 9/17/2003 K-40 2.67E+03 3.20E+02 6.20E+02 FH 30 L6182-01 9/17/2003 Mn-54 4.00E+00 1.20E+01 4.30E+01 FH 30 L6182-01 9/17/2003 Ru-103
-7.00E+00 1.50E+01 5.80E+01 FH 30 L6182-01 9/17/2003 Ru-106 3.00E+00 8.70E+01 3.30E+02 FH 30 L6182-01 9/17/2003 Sb-124 0.00E+00 3.40E+01 1.40E+02 FH 30 L6182-01 9/17/2003 Zn-65
-5.00E+00 2.30E+01 9.10E+01 FH 30 L6182-01 9/17/2003 Zr-95
-8.00E+00 2.20E+01 8.80E+01 FH 30 L6182-04 9/17/2003 Ag-110m
-4.00E+00 1.40E+01 5.20E+01 FH 30 L6182-04 9/17/2003 Ba-140 1.80E+01 3.20E+01 1.20E+02 FH 30 L6182-04 9/17/2003 Be-7
-2.30E+01 9.00E+01 3.30E+02 FH 30 L6182-04 9/17/2003 Ce-141
-1.40E+01 2.00E+01 7.20E+01 FH 30 L6182-04 9/17/2003 Ce-144 7.90E+01 4.80E+01 1.60E+02 FH 30 L6182-04 9/17/2003 Co-57
-3.90E+00 5.60E+00 2.10E+01 FH 30 L6182-04 9/17/2003 Co-58
-1.40E+01 1.10E+01 4.40E+01 FH 30 L6182-04 9/17/2003 Co-60
-5.90E+00 8.10E+00 3.40E+01 FH 30 L6182-04 9/17/2003 Cs-134 8.00E+00 8.90E+00 3.10E+01 FH 30 L6182-04 9/17/2003 Cs-137 1.97E+01 8.00E+00 2.40E+01 FH 30 L6182-04 9/17/2003 Fe-59
-2.60E+01 2.60E+01 1.10E+02 FH 30 L6182-04 9/17/2003 I-131
-9.20E+01 7.90E+01 3.10E+02 FH 30 L6182-04 9/17/2003 K-40 2.14E+03 2.50E+02 5.30E+02 FH 30 L6182-04 9/17/2003 Mn-54
-8.80E+00 9.20E+00 3.70E+01 FH 30 L6182-04 9/17/2003 Ru-103
-1.50E+01 1.40E+01 5.30E+01 FH 30 L6182-04 9/17/2003 Ru-106
-1.68E+02 8.30E+01 3.40E+02 FH 30 L6182-04 9/17/2003 Sb-124 1.30E+01 2.60E+01 9.70E+01 FH 30 L6182-04 9/17/2003 Zn-65
-9.00E+00 2.40E+01 9.00E+01 FH 30 L6182-04 9/17/2003 Zr-95 3.00E+00 1.60E+01 5.90E+01
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-16 FISH FH 30 L6183-01 9/17/2003 Ag-110m 1.90E+01 1.40E+01 4.60E+01 FH 30 L6183-01 9/17/2003 Ba-140 4.90E+01 4.90E+01 1.80E+02 FH 30 L6183-01 9/17/2003 Be-7 7.00E+01 1.20E+02 4.30E+02 FH 30 L6183-01 9/17/2003 Ce-141 3.60E+01 2.50E+01 8.40E+01 FH 30 L6183-01 9/17/2003 Ce-144 6.20E+01 6.20E+01 2.10E+02 FH 30 L6183-01 9/17/2003 Co-57 6.60E+00 7.60E+00 2.60E+01 FH 30 L6183-01 9/17/2003 Co-58
-6.00E+00 1.20E+01 5.00E+01 FH 30 L6183-01 9/17/2003 Co-60
-1.00E+01 1.40E+01 5.80E+01 FH 30 L6183-01 9/17/2003 Cs-134 0.00E+00 1.30E+01 4.90E+01 FH 30 L6183-01 9/17/2003 Cs-137
-1.90E+01 1.10E+01 5.00E+01 FH 30 L6183-01 9/17/2003 Fe-59 4.20E+01 4.20E+01 1.50E+02 FH 30 L6183-01 9/17/2003 I-131 9.00E+01 1.00E+02 3.60E+02 FH 30 L6183-01 9/17/2003 K-40 1.78E+03 3.10E+02 7.30E+02 FH 30 L6183-01 9/17/2003 Mn-54
-1.00E+01 1.20E+01 5.10E+01 FH 30 L6183-01 9/17/2003 Ru-103 4.00E+01 1.70E+01 5.10E+01 FH 30 L6183-01 9/17/2003 Ru-106
-1.70E+02 1.30E+02 5.10E+02 FH 30 L6183-01 9/17/2003 Sb-124
-3.50E+01 3.10E+01 1.50E+02 FH 30 L6183-01 9/17/2003 Zn-65
-4.00E+01 2.50E+01 1.20E+02 FH 30 L6183-01 9/17/2003 Zr-95 2.80E+01 2.60E+01 8.80E+01 FH 30 L6183-04 9/17/2003 Ag-110m 1.50E+01 1.50E+01 5.30E+01 FH 30 L6183-04 9/17/2003 Ba-140 3.30E+01 3.30E+01 1.20E+02 FH 30 L6183-04 9/17/2003 Be-7
-2.30E+02 1.20E+02 5.20E+02 FH 30 L6183-04 9/17/2003 Ce-141
-5.20E+01 2.60E+01 1.00E+02 FH 30 L6183-04 9/17/2003 Ce-144 7.20E+01 6.80E+01 2.30E+02 FH 30 L6183-04 9/17/2003 Co-57 7.90E+00 7.80E+00 2.70E+01 FH 30 L6183-04 9/17/2003 Co-58
-6.00E+00 1.50E+01 5.90E+01 FH 30 L6183-04 9/17/2003 Co-60 1.00E+01 1.00E+01 3.70E+01 FH 30 L6183-04 9/17/2003 Cs-134 1.70E+01 1.20E+01 4.00E+01 FH 30 L6183-04 9/17/2003 Cs-137 6.00E+00 1.20E+01 4.30E+01 FH 30 L6183-04 9/17/2003 Fe-59
-5.90E+01 4.50E+01 2.00E+02 FH 30 L6183-04 9/17/2003 I-131 0.00E+00 1.20E+02 4.50E+02 FH 30 L6183-04 9/17/2003 K-40 1.43E+03 2.90E+02 7.00E+02 FH 30 L6183-04 9/17/2003 Mn-54 5.00E+00 1.30E+01 4.70E+01 FH 30 L6183-04 9/17/2003 Ru-103
-1.10E+01 1.80E+01 7.10E+01 FH 30 L6183-04 9/17/2003 Ru-106
-4.00E+01 1.00E+02 4.10E+02 FH 30 L6183-04 9/17/2003 Sb-124 4.60E+01 3.70E+01 1.20E+02 FH 30 L6183-04 9/17/2003 Zn-65 4.20E+01 2.60E+01 8.30E+01 FH 30 L6183-04 9/17/2003 Zr-95 1.10E+01 2.70E+01 1.00E+02
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-17 SEDIMENT SE 28 L5626-01 6/9/2003 AcTh-228 8.27E+02 4.80E+01 1.90E+02 SE 28 L5626-01 6/9/2003 Be-7 1.70E+02 1.00E+02 3.40E+02 SE 28 L5626-01 6/9/2003 Co-58
-2.00E+01 1.10E+01 4.20E+01 SE 28 L5626-01 6/9/2003 Co-60 1.80E+01 1.20E+01 4.10E+01 SE 28 L5626-01 6/9/2003 Cs-134 1.00E+01 2.30E+01 7.70E+01 SE 28 L5626-01 6/9/2003 Cs-137 2.90E+01 1.60E+01 5.20E+01 SE 28 L5626-01 6/9/2003 K-40 9.41E+03 4.00E+02 3.80E+02 SE 28 L6181-01 9/17/2003 AcTh-228 6.02E+02 4.80E+01 1.70E+02 SE 28 L6181-01 9/17/2003 Be-7 2.70E+02 2.00E+02 6.70E+02 SE 28 L6181-01 9/17/2003 Co-58
-2.60E+01 1.10E+01 4.20E+01 SE 28 L6181-01 9/17/2003 Co-60 8.00E+00 1.10E+01 3.80E+01 SE 28 L6181-01 9/17/2003 Cs-134
-4.10E+01 4.30E+01 6.10E+01 SE 28 L6181-01 9/17/2003 Cs-137 1.09E+02 1.80E+01 5.20E+01 SE 28 L6181-01 9/17/2003 K-40 1.07E+04 4.00E+02 3.90E+02 SE 29 L5626-02 6/9/2003 AcTh-228 6.05E+02 3.50E+01 1.30E+02 SE 29 L5626-02 6/9/2003 Be-7 3.30E+02 1.90E+02 6.20E+02 SE 29 L5626-02 6/9/2003 Co-58
-8.10E+00 8.50E+00 3.10E+01 SE 29 L5626-02 6/9/2003 Co-60 1.25E+01 7.10E+00 2.30E+01 SE 29 L5626-02 6/9/2003 Cs-134
-1.10E+01 3.20E+01 5.80E+01 SE 29 L5626-02 6/9/2003 Cs-137 6.10E+01 1.20E+01 3.60E+01 SE 29 L5626-02 6/9/2003 K-40 9.57E+03 3.10E+02 3.50E+02 SE 29 L6181-02 9/16/2003 AcTh-228 4.04E+02 4.40E+01 1.50E+02 SE 29 L6181-02 9/16/2003 Be-7 2.00E+01 9.70E+01 3.40E+02 SE 29 L6181-02 9/16/2003 Co-58 8.00E+00 1.00E+01 3.50E+01 SE 29 L6181-02 9/16/2003 Co-60 3.02E+02 1.60E+01 4.40E+01 SE 29 L6181-02 9/16/2003 Cs-134 1.20E+01 3.90E+01 1.30E+02 SE 29 L6181-02 9/16/2003 Cs-137 1.55E+02 1.90E+01 5.00E+01 SE 29 L6181-02 9/16/2003 K-40 9.76E+03 3.60E+02 3.00E+02 SE 30 L5626-03 6/10/2003 AcTh-228 1.19E+03 5.50E+01 1.90E+02 SE 30 L5626-03 6/10/2003 Be-7 3.70E+02 2.40E+02 7.80E+02 SE 30 L5626-03 6/10/2003 Co-58
-1.80E+01 1.30E+01 4.80E+01 SE 30 L5626-03 6/10/2003 Co-60 1.30E+01 1.20E+01 4.00E+01 SE 30 L5626-03 6/10/2003 Cs-134
-4.00E+00 5.00E+01 7.30E+01 SE 30 L5626-03 6/10/2003 Cs-137 1.86E+02 2.10E+01 5.30E+01 SE 30 L5626-03 6/10/2003 K-40 1.70E+04 5.00E+02 4.20E+02 SE 30 L6181-03 9/16/2003 AcTh-228 9.55E+02 4.90E+01 1.90E+02 SE 30 L6181-03 9/16/2003 Be-7 3.40E+02 2.40E+02 8.10E+02 SE 30 L6181-03 9/16/2003 Co-58
-1.00E+00 1.10E+01 4.00E+01 SE 30 L6181-03 9/16/2003 Co-60 8.00E+00 1.20E+01 4.20E+01 SE 30 L6181-03 9/16/2003 Cs-134 7.00E+00 4.70E+01 7.30E+01 SE 30 L6181-03 9/16/2003 Cs-137 1.29E+02 1.90E+01 5.50E+01 SE 30 L6181-03 9/16/2003 K-40 1.41E+04 4.40E+02 4.20E+02
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-18 ISFSI SEDIMENT SE 57 L5748-01 6/30/2003 AcTh-228 4.90E+02 4.00E+01 1.40E+02 SE 57 L5748-01 6/30/2003 Be-7 8.60E+02 1.20E+02 3.50E+02 SE 57 L5748-01 6/30/2003 Co-58 2.60E+00 8.90E+00 3.10E+01 SE 57 L5748-01 6/30/2003 Co-60
-6.40E+00 9.20E+00 3.50E+01 SE 57 L5748-01 6/30/2003 Cs-134
-5.30E+01 3.90E+01 1.30E+02 SE 57 L5748-01 6/30/2003 Cs-137 3.28E+02 2.10E+01 4.20E+01 SE 57 L5748-01 6/30/2003 K-40 9.10E+03 3.50E+02 4.30E+02 SE 57 L6181-04 9/16/2003 AcTh-228 4.59E+02 4.50E+01 1.50E+02 SE 57 L6181-04 9/16/2003 Be-7 9.90E+02 1.70E+02 5.10E+02 SE 57 L6181-04 9/16/2003 Co-58
-2.10E+01 1.10E+01 4.10E+01 SE 57 L6181-04 9/16/2003 Co-60 1.60E+01 1.00E+01 3.40E+01 SE 57 L6181-04 9/16/2003 Cs-134
-1.00E+01 1.00E+01 3.70E+01 SE 57 L6181-04 9/16/2003 Cs-137 5.14E+02 2.50E+01 4.30E+01 SE 57 L6181-04 9/16/2003 K-40 8.15E+03 3.50E+02 4.40E+02 SE 58 L5748-02 6/30/2003 AcTh-228 1.00E+03 3.70E+01 1.30E+02 SE 58 L5748-02 6/30/2003 Be-7 3.50E+02 1.00E+02 3.30E+02 SE 58 L5748-02 6/30/2003 Co-58
-2.26E+01 9.00E+00 3.40E+01 SE 58 L5748-02 6/30/2003 Co-60 2.70E+00 8.60E+00 3.00E+01 SE 58 L5748-02 6/30/2003 Cs-134 5.30E+01 3.50E+01 1.20E+02 SE 58 L5748-02 6/30/2003 Cs-137 1.33E+02 1.40E+01 3.90E+01 SE 58 L5748-02 6/30/2003 K-40 1.09E+04 3.20E+02 3.30E+02 SE 58 L6181-05 9/17/2003 AcTh-228 8.52E+02 3.50E+01 1.10E+02 SE 58 L6181-05 9/17/2003 Be-7 1.03E+02 7.70E+01 2.60E+02 SE 58 L6181-05 9/17/2003 Co-58
-2.00E+00 1.30E+01 4.40E+01 SE 58 L6181-05 9/17/2003 Co-60 0.00E+00 7.60E+00 2.70E+01 SE 58 L6181-05 9/17/2003 Cs-134
-6.90E+01 3.20E+01 1.10E+02 SE 58 L6181-05 9/17/2003 Cs-137 1.17E+02 1.30E+01 3.50E+01 SE 58 L6181-05 9/17/2003 K-40 1.06E+04 2.90E+02 3.00E+02
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-19 SHELLFISH SF 27 L5640-08 6/10/2003 AcTh-228 1.61E+02 5.90E+01 1.70E+02 SF 27 L5640-08 6/10/2003 Co-58 7.00E+00 1.20E+01 4.60E+01 SF 27 L5640-08 6/10/2003 Co-60 2.20E+01 1.10E+01 2.90E+01 SF 27 L5640-08 6/10/2003 Cs-134 2.00E+01 1.60E+01 5.50E+01 SF 27 L5640-08 6/10/2003 Cs-137
-9.00E+00 1.20E+01 4.90E+01 SF 27 L5640-08 6/10/2003 Fe-59
-7.00E+00 2.30E+01 9.60E+01 SF 27 L5640-08 6/10/2003 K-40 2.70E+02 1.60E+02 5.10E+02 SF 27 L5640-08 6/10/2003 Mn-54 3.00E+00 1.00E+01 3.90E+01 SF 27 L5640-08 6/10/2003 Zn-65
-5.90E+01 3.10E+01 1.40E+02 SF 27 L6182-07 9/17/2003 Co-58 5.00E+00 1.20E+01 4.50E+01 SF 27 L6182-07 9/17/2003 Co-60 5.00E+00 1.10E+01 4.20E+01 SF 27 L6182-07 9/17/2003 Cs-134 4.00E+00 1.10E+01 4.30E+01 SF 27 L6182-07 9/17/2003 Cs-137
-2.00E+00 9.70E+00 3.80E+01 SF 27 L6182-07 9/17/2003 Fe-59
-2.10E+01 4.30E+01 1.80E+02 SF 27 L6182-07 9/17/2003 K-40 4.50E+02 1.70E+02 4.90E+02 SF 27 L6182-07 9/17/2003 Mn-54 1.00E+00 1.10E+01 4.10E+01 SF 27 L6182-07 9/17/2003 Zn-65 6.00E+00 2.60E+01 9.80E+01 SF 27 L6183-07 9/17/2003 Co-58 0.00E+00 1.10E+01 4.30E+01 SF 27 L6183-07 9/17/2003 Co-60 6.10E+00 8.10E+00 3.00E+01 SF 27 L6183-07 9/17/2003 Cs-134
-8.30E+00 8.80E+00 3.70E+01 SF 27 L6183-07 9/17/2003 Cs-137 9.00E-01 8.00E+00 3.10E+01 SF 27 L6183-07 9/17/2003 Fe-59
-3.00E+00 2.70E+01 1.10E+02 SF 27 L6183-07 9/17/2003 K-40 4.20E+02 1.30E+02 3.30E+02 SF 27 L6183-07 9/17/2003 Mn-54 3.80E+00 9.60E+00 3.60E+01 SF 27 L6183-07 9/17/2003 Zn-65 6.00E+00 3.50E+01 1.30E+02 SF 31 L5640-07 6/11/2003 AcTh-228 1.20E+02 5.10E+01 1.60E+02 SF 31 L5640-07 6/11/2003 Co-58 1.20E+01 1.10E+01 3.90E+01 SF 31 L5640-07 6/11/2003 Co-60
-6.00E+00 1.10E+01 4.80E+01 SF 31 L5640-07 6/11/2003 Cs-134 2.00E+00 1.10E+01 4.10E+01 SF 31 L5640-07 6/11/2003 Cs-137
-7.00E+00 1.10E+01 4.50E+01 SF 31 L5640-07 6/11/2003 Fe-59 0.00E+00 2.40E+01 9.30E+01 SF 31 L5640-07 6/11/2003 K-40 4.30E+02 1.80E+02 5.30E+02 SF 31 L5640-07 6/11/2003 Mn-54
-1.00E+01 1.20E+01 4.90E+01 SF 31 L5640-07 6/11/2003 Zn-65 1.14E+02 4.50E+01 1.40E+02 SF 31 L6182-08 9/17/2003 Co-58 1.00E+01 1.30E+01 4.80E+01 SF 31 L6182-08 9/17/2003 Co-60
-1.10E+01 1.40E+01 6.10E+01 SF 31 L6182-08 9/17/2003 Cs-134
-2.20E+01 1.30E+01 5.50E+01 SF 31 L6182-08 9/17/2003 Cs-137
-8.00E+00 1.30E+01 5.00E+01 SF 31 L6182-08 9/17/2003 Fe-59 4.40E+01 3.40E+01 1.20E+02 SF 31 L6182-08 9/17/2003 K-40 1.04E+03 2.30E+02 5.10E+02 SF 31 L6182-08 9/17/2003 Mn-54 2.00E+00 1.20E+01 4.50E+01 SF 31 L6182-08 9/17/2003 Zn-65
-7.90E+01 2.70E+01 1.30E+02
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-20 SHELLFISH SF 31 L6183-08 9/17/2003 Co-58 4.00E+00 1.00E+01 3.80E+01 SF 31 L6183-08 9/17/2003 Co-60
-2.20E+00 6.70E+00 2.90E+01 SF 31 L6183-08 9/17/2003 Cs-134 0.00E+00 9.70E+00 3.70E+01 SF 31 L6183-08 9/17/2003 Cs-137 1.48E+01 8.90E+00 2.90E+01 SF 31 L6183-08 9/17/2003 Fe-59
-2.30E+01 2.80E+01 1.20E+02 SF 31 L6183-08 9/17/2003 K-40
-7.20E+01 9.20E+01 3.90E+02 SF 31 L6183-08 9/17/2003 Mn-54
-1.70E+00 9.30E+00 3.60E+01 SF 31 L6183-08 9/17/2003 Zn-65
-3.20E+01 2.00E+01 8.90E+01
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-21 FOOD CROP TF 17 L5801-01 7/14/2003 Co-58 8.00E+00 1.10E+01 3.90E+01 TF 17 L5801-01 7/14/2003 Co-60
-1.30E+01 9.10E+00 4.30E+01 TF 17 L5801-01 7/14/2003 Cs-134 9.00E+00 1.00E+01 3.50E+01 TF 17 L5801-01 7/14/2003 Cs-137 6.40E+00 8.60E+00 3.10E+01 TF 17 L5801-01 7/14/2003 I-131
-2.00E+01 1.60E+02 6.00E+02 TF 17 L5801-01 7/14/2003 K-40 1.93E+03 2.60E+02 5.10E+02 TF 17 L6110-01 9/8/2003 Co-58
-1.30E+01 1.50E+01 6.50E+01 TF 17 L6110-01 9/8/2003 Co-60
-2.50E+01 1.70E+01 8.10E+01 TF 17 L6110-01 9/8/2003 Cs-134 1.10E+01 1.60E+01 5.80E+01 TF 17 L6110-01 9/8/2003 Cs-137 1.87E+01 9.90E+00 2.90E+01 TF 17 L6110-01 9/8/2003 I-131 4.30E+01 9.70E+01 3.60E+02 TF 17 L6110-01 9/8/2003 K-40 1.25E+03 3.20E+02 7.70E+02 TF 25 L5873-01 7/28/2003 Co-58
-3.60E+00 7.30E+00 2.80E+01 TF 25 L5873-01 7/28/2003 Co-60 5.60E+00 6.60E+00 2.30E+01 TF 25 L5873-01 7/28/2003 Cs-134 8.00E+00 6.90E+00 2.40E+01 TF 25 L5873-01 7/28/2003 Cs-137 3.80E+00 6.30E+00 2.30E+01 TF 25 L5873-01 7/28/2003 I-131
-2.00E+01 3.60E+01 1.30E+02 TF 25 L5873-01 7/28/2003 K-40 1.89E+03 1.90E+02 3.40E+02 TF 25 L6110-02 9/8/2003 Co-58
-2.00E+01 1.60E+01 6.70E+01 TF 25 L6110-02 9/8/2003 Co-60 1.00E+00 1.30E+01 5.30E+01 TF 25 L6110-02 9/8/2003 Cs-134
-7.00E+00 1.30E+01 5.30E+01 TF 25 L6110-02 9/8/2003 Cs-137
-1.10E+01 1.10E+01 4.60E+01 TF 25 L6110-02 9/8/2003 I-131
-2.00E+02 1.20E+02 4.80E+02 TF 25 L6110-02 9/8/2003 K-40 1.60E+03 2.90E+02 6.30E+02
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-22 BROAD LEAF VEGETATION TV 6
L5659-01 6/16/2003 Co-58
-1.40E+01 1.20E+01 4.70E+01 TV 6
L5659-01 6/16/2003 Co-60
-2.00E+00 1.10E+01 4.20E+01 TV 6
L5659-01 6/16/2003 Cs-134 2.00E+00 1.10E+01 4.10E+01 TV 6
L5659-01 6/16/2003 Cs-137 8.90E+01 1.70E+01 4.60E+01 TV 6
L5659-01 6/16/2003 I-131
-2.00E+00 2.50E+01 8.80E+01 TV 6
L5659-01 6/16/2003 K-40 2.55E+03 2.80E+02 5.10E+02 TV 6
L5800-01 7/14/2003 Co-58
-3.10E+01 1.30E+01 5.50E+01 TV 6
L5800-01 7/14/2003 Co-60
-7.00E+00 1.10E+01 4.50E+01 TV 6
L5800-01 7/14/2003 Cs-134
-5.00E+00 1.30E+01 4.80E+01 TV 6
L5800-01 7/14/2003 Cs-137
-1.00E+00 1.20E+01 4.40E+01 TV 6
L5800-01 7/14/2003 I-131 6.50E+01 3.10E+01 9.70E+01 TV 6
L5800-01 7/14/2003 K-40 5.25E+03 3.80E+02 5.70E+02 TV 6
L5966-01 8/11/2003 Co-58 3.00E+00 1.20E+01 4.40E+01 TV 6
L5966-01 8/11/2003 Co-60
-8.00E+00 1.20E+01 4.50E+01 TV 6
L5966-01 8/11/2003 Cs-134 3.00E+00 1.20E+01 4.30E+01 TV 6
L5966-01 8/11/2003 Cs-137 2.10E+01 1.00E+01 3.30E+01 TV 6
L5966-01 8/11/2003 I-131 8.40E+01 9.10E+01 3.10E+02 TV 6
L5966-01 8/11/2003 K-40 4.95E+03 3.40E+02 5.10E+02 TV 6
L6280-01 10/6/2003 Co-58
-1.10E+01 1.10E+01 4.20E+01 TV 6
L6280-01 10/6/2003 Co-60 2.00E+00 1.00E+01 3.90E+01 TV 6
L6280-01 10/6/2003 Cs-134 5.00E+00 1.00E+01 3.70E+01 TV 6
L6280-01 10/6/2003 Cs-137 1.40E+01 1.10E+01 3.70E+01 TV 6
L6280-01 10/6/2003 I-131
-3.00E+00 2.90E+01 1.10E+02 TV 6
L6280-01 10/6/2003 K-40 2.83E+03 2.70E+02 4.80E+02
- TV 6
L6111-02 9/8/2003 Co-58
-2.00E+00 1.30E+01 4.90E+01 TV 6
L6111-02 9/8/2003 Co-60 2.50E+01 1.40E+01 4.30E+01 TV 6
L6111-02 9/8/2003 Cs-134 2.50E+01 1.40E+01 4.40E+01 TV 6
L6111-02 9/8/2003 Cs-137 6.00E+00 1.20E+01 4.20E+01 TV 6
L6111-02 9/8/2003 I-131 3.00E+00 2.80E+01 1.00E+02 TV 6
L6111-02 9/8/2003 K-40 3.63E+03 3.80E+02 5.80E+02 TV 6
L5483-01 5/19/2003 Co-58
-5.00E+00 4.60E+00 2.00E+01 TV 6
L5483-01 5/19/2003 Co-60
-3.20E+00 6.70E+00 2.80E+01 TV 6
L5483-01 5/19/2003 Cs-134 1.08E+01 5.10E+00 1.50E+01 TV 6
L5483-01 5/19/2003 Cs-137 6.80E+00 4.80E+00 1.60E+01 TV 6
L5483-01 5/19/2003 I-131 1.30E+00 9.50E+00 3.60E+01 TV 6
L5483-01 5/19/2003 K-40 9.60E+02 1.50E+02 2.80E+02
- Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-23 BROAD LEAF VEGETATION TV 13 L5483-02 5/19/2003 Co-58 2.40E+00 3.50E+00 1.20E+01 TV 13 L5483-02 5/19/2003 Co-60 5.40E+00 3.80E+00 1.30E+01 TV 13 L5483-02 5/19/2003 Cs-134
-3.00E+00 3.10E+00 1.30E+01 TV 13 L5483-02 5/19/2003 Cs-137 1.69E+01 5.10E+00 1.50E+01 TV 13 L5483-02 5/19/2003 I-131
-1.71E+01 7.10E+00 3.10E+01 TV 13 L5483-02 5/19/2003 K-40 8.74E+02 9.00E+01 1.50E+02 TV 13 L5659-02 6/16/2003 Co-58
-7.00E+00 1.10E+01 3.90E+01 TV 13 L5659-02 6/16/2003 Co-60
-4.00E+00 1.10E+01 4.00E+01 TV 13 L5659-02 6/16/2003 Cs-134 8.00E+00 1.20E+01 4.30E+01 TV 13 L5659-02 6/16/2003 Cs-137 4.90E+01 1.70E+01 5.30E+01 TV 13 L5659-02 6/16/2003 I-131 1.20E+01 2.20E+01 7.50E+01 TV 13 L5659-02 6/16/2003 K-40 2.45E+03 2.60E+02 6.50E+02 TV 13 L5800-02 7/14/2003 Co-58
-2.30E+01 1.40E+01 6.20E+01 TV 13 L5800-02 7/14/2003 Co-60
-1.90E+01 1.20E+01 6.10E+01 TV 13 L5800-02 7/14/2003 Cs-134
-2.00E+00 1.40E+01 5.50E+01 TV 13 L5800-02 7/14/2003 Cs-137 3.30E+01 1.60E+01 5.00E+01 TV 13 L5800-02 7/14/2003 I-131
-1.50E+01 2.40E+01 9.70E+01 TV 13 L5800-02 7/14/2003 K-40 2.23E+03 3.60E+02 7.80E+02 TV 13 L5966-02 8/11/2003 Co-58 5.10E+00 8.20E+00 2.80E+01 TV 13 L5966-02 8/11/2003 Co-60 8.90E+00 7.10E+00 2.40E+01 TV 13 L5966-02 8/11/2003 Cs-134 5.00E-01 7.20E+00 2.50E+01 TV 13 L5966-02 8/11/2003 Cs-137 8.50E+01 1.00E+01 2.90E+01 TV 13 L5966-02 8/11/2003 I-131 3.30E+01 6.80E+01 2.30E+02 TV 13 L5966-02 8/11/2003 K-40 2.22E+03 1.50E+02 3.40E+02 TV 13 L6111-03 9/8/2003 Co-58 3.70E+01 1.30E+01 3.00E+01 TV 13 L6111-03 9/8/2003 Co-60
-1.50E+01 2.10E+01 8.80E+01 TV 13 L6111-03 9/8/2003 Cs-134 1.00E+00 1.30E+01 5.30E+01 TV 13 L6111-03 9/8/2003 Cs-137 9.00E+00 1.30E+01 4.60E+01 TV 13 L6111-03 9/8/2003 I-131 4.50E+01 4.30E+01 1.50E+02 TV 13 L6111-03 9/8/2003 K-40 3.77E+03 5.10E+02 9.90E+02 TV 13 L6280-02 10/6/2003 Co-58 1.30E+01 1.10E+01 4.00E+01 TV 13 L6280-02 10/6/2003 Co-60 1.90E+01 1.40E+01 4.80E+01 TV 13 L6280-02 10/6/2003 Cs-134
-1.50E+01 1.50E+01 5.90E+01 TV 13 L6280-02 10/6/2003 Cs-137 2.70E+01 1.50E+01 4.70E+01 TV 13 L6280-02 10/6/2003 I-131 2.10E+01 3.90E+01 1.40E+02 TV 13 L6280-02 10/6/2003 K-40 1.75E+03 2.80E+02 6.00E+02
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-24 BROAD LEAF VEGETATION TV 18 L5483-03 5/19/2003 Co-58 0.00E+00 7.20E+00 2.80E+01 TV 18 L5483-03 5/19/2003 Co-60
-5.60E+00 6.20E+00 2.80E+01 TV 18 L5483-03 5/19/2003 Cs-134 1.50E+00 7.10E+00 2.70E+01 TV 18 L5483-03 5/19/2003 Cs-137 3.00E+00 5.70E+00 2.10E+01 TV 18 L5483-03 5/19/2003 I-131
-1.90E+01 1.80E+01 7.20E+01 TV 18 L5483-03 5/19/2003 K-40 1.66E+03 2.10E+02 4.10E+02 TV 18 L5659-03 6/16/2003 Co-58 1.20E+01 9.40E+00 3.20E+01 TV 18 L5659-03 6/16/2003 Co-60 1.30E+01 1.10E+01 3.60E+01 TV 18 L5659-03 6/16/2003 Cs-134
-1.00E+01 1.00E+01 3.90E+01 TV 18 L5659-03 6/16/2003 Cs-137 1.90E+01 1.00E+01 3.30E+01 TV 18 L5659-03 6/16/2003 I-131 2.70E+01 1.60E+01 5.20E+01 TV 18 L5659-03 6/16/2003 K-40 2.67E+03 2.60E+02 4.90E+02 TV 18 L5800-03 7/14/2003 Co-58
-1.80E+01 1.00E+01 4.10E+01 TV 18 L5800-03 7/14/2003 Co-60 1.50E+01 1.00E+01 3.50E+01 TV 18 L5800-03 7/14/2003 Cs-134 8.00E+00 1.10E+01 3.70E+01 TV 18 L5800-03 7/14/2003 Cs-137 1.43E+01 8.80E+00 2.90E+01 TV 18 L5800-03 7/14/2003 I-131 7.00E+00 2.20E+01 7.80E+01 TV 18 L5800-03 7/14/2003 K-40 2.69E+03 2.60E+02 5.10E+02 TV 18 L5966-03 8/11/2003 Co-58
-1.70E+01 1.40E+01 5.50E+01 TV 18 L5966-03 8/11/2003 Co-60
-2.50E+01 1.40E+01 5.70E+01 TV 18 L5966-03 8/11/2003 Cs-134 7.00E+00 1.20E+01 4.30E+01 TV 18 L5966-03 8/11/2003 Cs-137 9.90E+01 1.70E+01 4.50E+01 TV 18 L5966-03 8/11/2003 I-131 1.40E+02 1.00E+02 3.40E+02 TV 18 L5966-03 8/11/2003 K-40 3.34E+03 3.10E+02 5.70E+02 TV 18 L6111-01 9/8/2003 Co-58 1.10E+01 1.00E+01 3.50E+01 TV 18 L6111-01 9/8/2003 Co-60
-1.90E+01 1.10E+01 4.80E+01 TV 18 L6111-01 9/8/2003 Cs-134 9.00E+00 1.30E+01 4.40E+01 TV 18 L6111-01 9/8/2003 Cs-137 2.80E+01 1.30E+01 4.00E+01 TV 18 L6111-01 9/8/2003 I-131
-4.20E+01 3.60E+01 1.40E+02 TV 18 L6111-01 9/8/2003 K-40 3.19E+03 3.20E+02 5.80E+02 TV 18 L6280-03 10/6/2003 Co-58
-9.00E-01 6.90E+00 2.40E+01 TV 18 L6280-03 10/6/2003 Co-60
-1.39E+01 7.20E+00 2.70E+01 TV 18 L6280-03 10/6/2003 Cs-134 5.00E-01 7.40E+00 2.50E+01 TV 18 L6280-03 10/6/2003 Cs-137 1.44E+01 7.20E+00 2.40E+01 TV 18 L6280-03 10/6/2003 I-131 1.70E+01 2.10E+01 6.90E+01 TV 18 L6280-03 10/6/2003 K-40 3.20E+03 1.80E+02 4.10E+02
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/kg) (pCi/kg) (pCi/kg)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-25 BROAD LEAF VEGETATION TV 41 L6111-04 9/8/2003 Co-58
-2.30E+01 1.30E+01 5.70E+01 TV 41 L6111-04 9/8/2003 Co-60
-2.40E+01 1.30E+01 5.70E+01 TV 41 L6111-04 9/8/2003 Cs-134 9.00E+00 1.30E+01 4.50E+01 TV 41 L6111-04 9/8/2003 Cs-137
-1.30E+01 1.20E+01 4.80E+01 TV 41 L6111-04 9/8/2003 I-131 1.40E+01 3.70E+01 1.30E+02 TV 41 L6111-04 9/8/2003 K-40 2.64E+03 3.30E+02 6.70E+02 TV 41 L5659-04 6/16/2003 Co-58 2.00E+00 1.10E+01 3.90E+01 TV 41 L5659-04 6/16/2003 Co-60
-2.00E+01 1.20E+01 5.00E+01 TV 41 L5659-04 6/16/2003 Cs-134 3.00E+00 1.20E+01 4.10E+01 TV 41 L5659-04 6/16/2003 Cs-137
-9.50E+00 9.30E+00 3.50E+01 TV 41 L5659-04 6/16/2003 I-131 2.60E+01 1.70E+01 5.50E+01 TV 41 L5659-04 6/16/2003 K-40 2.46E+03 2.70E+02 6.20E+02 TV 41 L5800-04 7/14/2003 Co-58 5.00E+00 1.40E+01 5.20E+01 TV 41 L5800-04 7/14/2003 Co-60
-7.00E+00 1.60E+01 6.20E+01 TV 41 L5800-04 7/14/2003 Cs-134
-8.00E+00 1.40E+01 5.40E+01 TV 41 L5800-04 7/14/2003 Cs-137 2.00E+01 1.50E+01 5.10E+01 TV 41 L5800-04 7/14/2003 I-131 1.50E+01 3.70E+01 1.30E+02 TV 41 L5800-04 7/14/2003 K-40 2.75E+03 3.80E+02 8.40E+02 TV 41 L5966-04 8/11/2003 Co-58 7.00E+00 1.30E+01 4.80E+01 TV 41 L5966-04 8/11/2003 Co-60 2.00E+00 1.40E+01 5.70E+01 TV 41 L5966-04 8/11/2003 Cs-134 6.00E+00 1.10E+01 4.30E+01 TV 41 L5966-04 8/11/2003 Cs-137 0.00E+00 1.20E+01 4.60E+01 TV 41 L5966-04 8/11/2003 I-131 1.00E+02 1.00E+02 3.40E+02 TV 41 L5966-04 8/11/2003 K-40 3.60E+03 4.40E+02 7.80E+02 TV 41 L6280-04 10/6/2003 Co-58
-1.46E+01 9.70E+00 4.00E+01 TV 41 L6280-04 10/6/2003 Co-60
-6.00E+00 1.20E+01 4.90E+01 TV 41 L6280-04 10/6/2003 Cs-134 1.30E+01 1.10E+01 3.70E+01 TV 41 L6280-04 10/6/2003 Cs-137 1.10E+01 9.50E+00 3.20E+01 TV 41 L6280-04 10/6/2003 I-131
-2.00E+01 2.40E+01 9.20E+01 TV 41 L6280-04 10/6/2003 K-40 2.92E+03 3.00E+02 5.20E+02 TV 41 L5483-04 5/19/2003 Co-58 5.00E-01 4.80E+00 2.00E+01 TV 41 L5483-04 5/19/2003 Co-60
-5.20E+00 5.60E+00 2.70E+01 TV 41 L5483-04 5/19/2003 Cs-134
-1.30E+00 5.20E+00 2.20E+01 TV 41 L5483-04 5/19/2003 Cs-137 2.50E+00 3.10E+00 1.20E+01 TV 41 L5483-04 5/19/2003 I-131 1.30E+01 1.00E+01 3.50E+01 TV 41 L5483-04 5/19/2003 K-40 9.00E+02 1.60E+02 3.10E+02
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/l) (pCi/l) (pCi/l)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-26 ISFSI WATER WG 57 L5740-01 6/30/2003 AcTh-228 5.40E+00 3.70E+00 1.20E+01 WG 57 L5740-01 6/30/2003 Ag-110m
-2.40E+00 1.20E+00 4.80E+00 WG 57 L5740-01 6/30/2003 Ba-140 1.90E+00 1.50E+00 5.20E+00 WG 57 L5740-01 6/30/2003 Be-7
-4.90E+00 6.10E+00 2.20E+01 WG 57 L5740-01 6/30/2003 Ce-141 1.30E+00 1.40E+00 4.80E+00 WG 57 L5740-01 6/30/2003 Ce-144
-3.10E+00 5.40E+00 1.90E+01 WG 57 L5740-01 6/30/2003 Co-57 3.00E-02 7.00E-01 2.40E+00 WG 57 L5740-01 6/30/2003 Co-58 1.02E+00 7.40E-01 2.50E+00 WG 57 L5740-01 6/30/2003 Co-60
-2.30E-01 9.20E-01 3.40E+00 WG 57 L5740-01 6/30/2003 Cs-134 1.12E+00 9.00E-01 3.00E+00 WG 57 L5740-01 6/30/2003 Cs-137
-2.60E-01 8.20E-01 3.00E+00 WG 57 L5740-01 6/30/2003 Fe-59
-1.80E+00 1.80E+00 6.80E+00 WG 57 L5740-01 6/30/2003 H-3 6.00E+01 4.00E+02 1.20E+03 WG 57 L5740-01 6/30/2003 I-131
-3.60E+00 1.50E+00 5.80E+00 WG 57 L5740-01 6/30/2003 K-40 4.00E+00 1.30E+01 4.40E+01 WG 57 L5740-01 6/30/2003 La-140 2.20E+00 1.80E+00 5.90E+00 WG 57 L5740-01 6/30/2003 Mn-54
-7.30E-01 8.30E-01 3.10E+00 WG 57 L5740-01 6/30/2003 Nb-95 8.60E-01 9.00E-01 3.10E+00 WG 57 L5740-01 6/30/2003 Ru-103
-3.90E-01 8.20E-01 3.00E+00 WG 57 L5740-01 6/30/2003 Ru-106 4.40E+00 7.30E+00 2.50E+01 WG 57 L5740-01 6/30/2003 Sb-124
-3.10E+00 2.20E+00 8.90E+00 WG 57 L5740-01 6/30/2003 Zn-65 7.80E+00 2.90E+00 9.10E+00 WG 57 L5740-01 6/30/2003 Zr-95 1.40E+00 1.40E+00 4.70E+00 WG 57 L6282-01 10/6/2003 AcTh-228 8.10E+00 4.70E+00 1.50E+01 WG 57 L6282-01 10/6/2003 Ag-110m 9.00E-01 1.70E+00 6.10E+00 WG 57 L6282-01 10/6/2003 Ba-140 1.20E+00 2.60E+00 9.70E+00 WG 57 L6282-01 10/6/2003 Be-7 6.00E+00 1.10E+01 3.90E+01 WG 57 L6282-01 10/6/2003 Ce-141 3.30E+00 2.60E+00 8.70E+00 WG 57 L6282-01 10/6/2003 Ce-144
-3.80E+00 8.90E+00 3.20E+01 WG 57 L6282-01 10/6/2003 Co-57 5.00E-01 1.10E+00 3.80E+00 WG 57 L6282-01 10/6/2003 Co-58 4.00E-01 1.20E+00 4.40E+00 WG 57 L6282-01 10/6/2003 Co-60
-3.00E-01 1.20E+00 4.80E+00 WG 57 L6282-01 10/6/2003 Cs-134 1.80E+00 1.20E+00 4.20E+00 WG 57 L6282-01 10/6/2003 Cs-137
-1.10E+00 1.10E+00 4.60E+00 WG 57 L6282-01 10/6/2003 Fe-59
-7.00E-01 3.20E+00 1.30E+01 WG 57 L6282-01 10/6/2003 H-3
-1.10E+02 4.20E+02 1.30E+03 WG 57 L6282-01 10/6/2003 I-131
-1.40E+00 4.30E+00 1.60E+01 WG 57 L6282-01 10/6/2003 K-40
-3.00E+00 1.50E+01 5.70E+01 WG 57 L6282-01 10/6/2003 La-140 1.30E+00 3.00E+00 1.10E+01 WG 57 L6282-01 10/6/2003 Mn-54 6.00E-01 1.10E+00 4.00E+00 WG 57 L6282-01 10/6/2003 Nb-95
-1.80E+00 1.80E+00 6.80E+00 WG 57 L6282-01 10/6/2003 Ru-103 5.00E-01 1.80E+00 6.40E+00 WG 57 L6282-01 10/6/2003 Ru-106
-2.00E+00 1.20E+01 4.30E+01 WG 57 L6282-01 10/6/2003 Sb-124
-7.00E-01 3.30E+00 1.30E+01 WG 57 L6282-01 10/6/2003 Zn-65
-6.40E+00 5.90E+00 2.20E+01 WG 57 L6282-01 10/6/2003 Zr-95
-8.00E-01 1.90E+00 7.60E+00
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/l) (pCi/l) (pCi/l)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-27 RIVER WATER WR 28 L5294-01 3/24/2003 Ba-140
-4.10E+00 5.00E+00 2.00E+01 WR 28 L5294-01 3/24/2003 Co-58 0.00E+00 1.10E+00 3.90E+00 WR 28 L5294-01 3/24/2003 Co-60
-4.00E-02 8.00E-01 3.10E+00 WR 28 L5294-01 3/24/2003 Cs-134 1.00E-01 1.00E+00 3.70E+00 WR 28 L5294-01 3/24/2003 Cs-137
-2.70E-01 9.00E-01 3.30E+00 WR 28 L5294-01 3/24/2003 Fe-59
-5.10E+00 2.90E+00 1.10E+01 WR 28 L5294-01 3/24/2003 H-3
-6.80E+02 4.40E+02 1.40E+03 WR 28 L5294-01 3/24/2003 I-131
-1.20E+01 1.20E+01 4.50E+01 WR 28 L5294-01 3/24/2003 Mn-54 6.90E-01 9.20E-01 3.20E+00 WR 28 L5294-01 3/24/2003 Zn-65 2.40E+00 4.00E+00 1.40E+01 WR 28 L5294-01 3/24/2003 Zr-95 1.00E+00 1.80E+00 6.30E+00 WR 28 L5938-01 6/30/2003 Ba-140
-1.30E+01 1.80E+01 7.60E+01 WR 28 L5938-01 6/30/2003 Co-58
-1.00E-01 2.00E+00 7.50E+00 WR 28 L5938-01 6/30/2003 Co-60
-6.00E-01 1.20E+00 4.80E+00 WR 28 L5938-01 6/30/2003 Cs-134 1.20E+00 1.30E+00 4.50E+00 WR 28 L5938-01 6/30/2003 Cs-137 1.00E+00 1.30E+00 4.40E+00 WR 28 L5938-01 6/30/2003 Fe-59 1.70E+00 4.60E+00 1.70E+01 WR 28 L5938-01 6/30/2003 H-3
-7.10E+02 3.80E+02 1.20E+03 WR 28 L5938-01 6/30/2003 I-131 1.14E+02 6.70E+01 2.20E+02 WR 28 L5938-01 6/30/2003 Mn-54
-5.00E-01 1.10E+00 4.50E+00 WR 28 L5938-01 6/30/2003 Zn-65 1.00E+00 2.90E+00 1.10E+01 WR 28 L5938-01 6/30/2003 Zr-95
-4.00E+00 3.60E+00 1.40E+01 WR 28 L6419-01 9/22/2003 Ba-140
-2.00E+01 1.50E+01 7.20E+01 WR 28 L6419-01 9/22/2003 Co-58 5.00E-01 2.10E+00 7.90E+00 WR 28 L6419-01 9/22/2003 Co-60
-3.10E+00 2.00E+00 8.80E+00 WR 28 L6419-01 9/22/2003 Cs-134
-6.00E-01 1.60E+00 6.30E+00 WR 28 L6419-01 9/22/2003 Cs-137
-3.70E+00 1.40E+00 6.30E+00 WR 28 L6419-01 9/22/2003 Fe-59 9.00E+00 7.00E+00 2.40E+01 WR 28 L6419-01 9/22/2003 H-3 4.10E+02 4.20E+02 1.20E+03 WR 28 L6419-01 9/22/2003 I-131 4.90E+01 5.30E+01 1.80E+02 WR 28 L6419-01 9/22/2003 Mn-54
-1.60E+00 1.60E+00 6.60E+00 WR 28 L6419-01 9/22/2003 Zn-65
-2.30E+00 3.30E+00 1.40E+01 WR 28 L6419-01 9/22/2003 Zr-95 2.90E+00 3.20E+00 1.10E+01 WR 28 L6792-01 12/29/2003 Ba-140
-1.14E+01 5.80E+00 2.60E+01 WR 28 L6792-01 12/29/2003 Co-58
-2.50E+00 1.00E+00 4.60E+00 WR 28 L6792-01 12/29/2003 Co-60
-1.30E+00 1.10E+00 4.50E+00 WR 28 L6792-01 12/29/2003 Cs-134 1.50E-01 9.30E-01 3.40E+00 WR 28 L6792-01 12/29/2003 Cs-137
-7.70E-01 9.60E-01 3.70E+00 WR 28 L6792-01 12/29/2003 Fe-59
-1.40E+00 2.90E+00 1.20E+01 WR 28 L6792-01 12/29/2003 H-3 4.80E+02 3.00E+02 9.50E+02 WR 28 L6792-01 12/29/2003 I-131 2.20E+01 1.90E+01 6.60E+01 WR 28 L6792-01 12/29/2003 Mn-54
-2.80E-01 9.70E-01 3.60E+00 WR 28 L6792-01 12/29/2003 Zn-65
-5.00E+00 2.60E+00 1.00E+01 WR 28 L6792-01 12/29/2003 Zr-95
-9.00E-01 2.30E+00 8.70E+00
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/l) (pCi/l) (pCi/l)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-28 RIVER WATER WR 30 L5294-02 3/24/2003 Ba-140 1.60E+00 8.00E+00 3.00E+01 WR 30 L5294-02 3/24/2003 Co-58
-1.50E+00 1.50E+00 6.00E+00 WR 30 L5294-02 3/24/2003 Co-60 1.20E+00 1.10E+00 4.00E+00 WR 30 L5294-02 3/24/2003 Cs-134
-2.00E-01 1.20E+00 4.60E+00 WR 30 L5294-02 3/24/2003 Cs-137
-4.00E-01 1.20E+00 4.60E+00 WR 30 L5294-02 3/24/2003 Fe-59 6.90E+00 4.10E+00 1.30E+01 WR 30 L5294-02 3/24/2003 H-3
-6.00E+02 4.20E+02 1.30E+03 WR 30 L5294-02 3/24/2003 I-131
-2.60E+01 1.50E+01 5.90E+01 WR 30 L5294-02 3/24/2003 Mn-54 2.10E+00 1.20E+00 4.00E+00 WR 30 L5294-02 3/24/2003 Zn-65 1.60E+00 2.90E+00 1.10E+01 WR 30 L5294-02 3/24/2003 Zr-95 2.00E+00 2.70E+00 9.40E+00 WR 30 L5938-02 6/30/2003 Ba-140
-8.00E+00 2.00E+01 8.10E+01 WR 30 L5938-02 6/30/2003 Co-58
-1.50E+00 1.50E+00 6.30E+00 WR 30 L5938-02 6/30/2003 Co-60 5.00E-01 1.20E+00 4.50E+00 WR 30 L5938-02 6/30/2003 Cs-134
-9.00E-01 1.20E+00 4.80E+00 WR 30 L5938-02 6/30/2003 Cs-137 1.70E+00 1.20E+00 3.80E+00 WR 30 L5938-02 6/30/2003 Fe-59 4.30E+00 4.40E+00 1.60E+01 WR 30 L5938-02 6/30/2003 H-3
-2.10E+02 4.00E+02 1.20E+03 WR 30 L5938-02 6/30/2003 I-131 3.40E+01 7.60E+01 2.60E+02 WR 30 L5938-02 6/30/2003 Mn-54 1.80E+00 1.20E+00 4.00E+00 WR 30 L5938-02 6/30/2003 Zn-65
-7.60E+00 3.60E+00 1.50E+01 WR 30 L5938-02 6/30/2003 Zr-95
-2.70E+00 2.70E+00 1.10E+01 WR 30 L6419-02 9/22/2003 Ba-140
-1.00E+01 1.80E+01 7.80E+01 WR 30 L6419-02 9/22/2003 Co-58 4.00E-01 2.20E+00 8.10E+00 WR 30 L6419-02 9/22/2003 Co-60
-3.30E+00 1.80E+00 8.00E+00 WR 30 L6419-02 9/22/2003 Cs-134 1.20E+00 1.20E+00 4.10E+00 WR 30 L6419-02 9/22/2003 Cs-137
-2.30E+00 1.50E+00 6.20E+00 WR 30 L6419-02 9/22/2003 Fe-59
-1.10E+00 6.00E+00 2.50E+01 WR 30 L6419-02 9/22/2003 H-3 2.20E+02 4.10E+02 1.20E+03 WR 30 L6419-02 9/22/2003 I-131 3.70E+01 6.40E+01 2.30E+02 WR 30 L6419-02 9/22/2003 Mn-54 6.00E-01 1.50E+00 5.60E+00 WR 30 L6419-02 9/22/2003 Zn-65
-5.30E+00 4.10E+00 1.70E+01 WR 30 L6419-02 9/22/2003 Zr-95 5.00E-01 3.50E+00 1.30E+01 WR 30 L6792-02 12/29/2003 Ba-140
-5.00E-01 7.00E+00 2.70E+01 WR 30 L6792-02 12/29/2003 Co-58 0.00E+00 1.30E+00 4.90E+00 WR 30 L6792-02 12/29/2003 Co-60
-1.40E+00 1.00E+00 4.20E+00 WR 30 L6792-02 12/29/2003 Cs-134
-1.05E+00 8.60E-01 3.50E+00 WR 30 L6792-02 12/29/2003 Cs-137 1.90E+00 1.10E+00 3.40E+00 WR 30 L6792-02 12/29/2003 Fe-59
-7.00E-01 4.00E+00 1.50E+01 WR 30 L6792-02 12/29/2003 H-3 2.30E+02 2.90E+02 9.40E+02 WR 30 L6792-02 12/29/2003 I-131
-6.00E+00 2.00E+01 7.30E+01 WR 30 L6792-02 12/29/2003 Mn-54
-1.40E-01 8.60E-01 3.20E+00 WR 30 L6792-02 12/29/2003 Zn-65
-5.10E+00 2.60E+00 1.10E+01 WR 30 L6792-02 12/29/2003 Zr-95 1.90E+00 2.00E+00 6.90E+00
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/l) (pCi/l) (pCi/l)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-29 WELL WATER WW 15 L4614-03 12/30/2002 Ba-140
-1.10E+00 1.50E+00 6.40E+00 WW 15 L4614-03 12/30/2002 Co-58
-6.40E-01 9.30E-01 3.70E+00 WW 15 L4614-03 12/30/2002 Co-60
-3.00E-01 1.20E+00 4.60E+00 WW 15 L4614-03 12/30/2002 Cs-134 1.70E+00 1.10E+00 3.50E+00 WW 15 L4614-03 12/30/2002 Cs-137
-1.00E-01 1.30E+00 4.60E+00 WW 15 L4614-03 12/30/2002 Fe-59
-2.40E+00 2.10E+00 8.70E+00 WW 15 L4614-03 12/30/2002 I-131
-7.00E-01 2.50E+00 8.90E+00 WW 15 L4614-03 12/30/2002 Mn-54
-1.00E+00 1.00E+00 4.10E+00 WW 15 L4614-03 12/30/2002 Zn-65 2.90E+00 2.30E+00 7.90E+00 WW 15 L4614-03 12/30/2002 Zr-95
-7.00E-01 1.70E+00 6.80E+00 WW 15 L5235-01 4/7/2003 Ba-140 0.00E+00 1.50E+00 6.10E+00 WW 15 L5235-01 4/7/2003 Co-58
-8.00E-01 1.10E+00 4.50E+00 WW 15 L5235-01 4/7/2003 Co-60 1.30E+00 1.30E+00 4.60E+00 WW 15 L5235-01 4/7/2003 Cs-134 1.20E+00 1.10E+00 3.90E+00 WW 15 L5235-01 4/7/2003 Cs-137 2.00E-01 1.20E+00 4.30E+00 WW 15 L5235-01 4/7/2003 Fe-59
-9.00E-01 2.40E+00 9.60E+00 WW 15 L5235-01 4/7/2003 H-3
-3.80E+02 4.00E+02 1.30E+03 WW 15 L5235-01 4/7/2003 I-131 1.00E+00 2.00E+00 7.20E+00 WW 15 L5235-01 4/7/2003 Mn-54 2.00E-01 1.10E+00 4.00E+00 WW 15 L5235-01 4/7/2003 Zn-65
-1.40E+00 2.60E+00 1.00E+01 WW 15 L5235-01 4/7/2003 Zr-95
-2.00E+00 2.00E+00 8.10E+00 WW 15 L5745-01 6/30/2003 Ba-140
-4.00E-01 2.30E+00 8.80E+00 WW 15 L5745-01 6/30/2003 Co-58
-3.00E-01 1.10E+00 4.20E+00 WW 15 L5745-01 6/30/2003 Co-60
-2.00E-01 1.10E+00 4.30E+00 WW 15 L5745-01 6/30/2003 Cs-134 1.50E+00 1.20E+00 4.10E+00 WW 15 L5745-01 6/30/2003 Cs-137 9.00E-01 1.30E+00 4.40E+00 WW 15 L5745-01 6/30/2003 Fe-59
-5.00E-01 2.20E+00 8.70E+00 WW 15 L5745-01 6/30/2003 H-3 5.00E+02 4.40E+02 1.30E+03 WW 15 L5745-01 6/30/2003 I-131
-1.90E+00 2.30E+00 8.50E+00 WW 15 L5745-01 6/30/2003 Mn-54 1.30E+00 1.20E+00 4.30E+00 WW 15 L5745-01 6/30/2003 Zn-65
-6.10E+00 2.70E+00 1.20E+01 WW 15 L5745-01 6/30/2003 Zr-95
-2.00E+00 2.00E+00 7.90E+00 WW 15 L6283-01 10/6/2003 Ba-140 2.10E+00 4.50E+00 1.70E+01 WW 15 L6283-01 10/6/2003 Co-58 9.00E-01 1.80E+00 6.80E+00 WW 15 L6283-01 10/6/2003 Co-60 7.00E-01 2.30E+00 8.70E+00 WW 15 L6283-01 10/6/2003 Cs-134 1.60E+00 2.30E+00 8.10E+00 WW 15 L6283-01 10/6/2003 Cs-137
-1.50E+00 1.90E+00 7.80E+00 WW 15 L6283-01 10/6/2003 Fe-59
-6.40E+00 4.50E+00 2.30E+01 WW 15 L6283-01 10/6/2003 H-3 3.60E+02 4.20E+02 1.30E+03 WW 15 L6283-01 10/6/2003 I-131 1.00E-01 5.00E+00 1.90E+01 WW 15 L6283-01 10/6/2003 Mn-54
-1.00E-01 1.70E+00 6.60E+00 WW 15 L6283-01 10/6/2003 Zn-65
-7.10E+00 4.60E+00 2.00E+01 WW 15 L6283-01 10/6/2003 Zr-95 1.00E+00 2.50E+00 9.90E+00
Haddam Neck Station Annual Radiological Environmental Operating Report 2003 Connecticut Yankee Radiological Environmental Monitoring Program Summary of 2003 Data SAMPLE END CONC STD.DEV. MDC TYPE STATION LSN DATE NUCLIDE (pCi/l) (pCi/l) (pCi/l)
Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
+
Minimum Detectable Concentration > Lower Limit of Detection Requirement C-30 WELL WATER WW 16 L5235-02 4/7/2003 Ba-140 1.80E+00 3.50E+00 1.30E+01 WW 16 L5235-02 4/7/2003 Co-58
-5.00E+00 2.40E+00 9.60E+00 WW 16 L5235-02 4/7/2003 Co-60
-2.00E+00 2.30E+00 9.10E+00 WW 16 L5235-02 4/7/2003 Cs-134 2.60E+00 2.30E+00 7.70E+00 WW 16 L5235-02 4/7/2003 Cs-137
-1.20E+00 2.10E+00 7.80E+00 WW 16 L5235-02 4/7/2003 Fe-59
-4.40E+00 3.90E+00 1.60E+01 WW 16 L5235-02 4/7/2003 H-3
-8.00E+01 4.40E+02 1.30E+03 WW 16 L5235-02 4/7/2003 I-131 4.00E+00 3.50E+00 1.20E+01 WW 16 L5235-02 4/7/2003 Mn-54 1.60E+00 1.70E+00 5.80E+00 WW 16 L5235-02 4/7/2003 Zn-65
-5.70E+00 4.40E+00 1.70E+01 WW 16 L5235-02 4/7/2003 Zr-95
-6.30E+00 3.50E+00 1.40E+01 WW 16 L5745-02 6/30/2003 Ba-140 4.10E+00 2.00E+00 6.50E+00 WW 16 L5745-02 6/30/2003 Co-58
-1.40E+00 1.30E+00 4.70E+00 WW 16 L5745-02 6/30/2003 Co-60 1.00E+00 1.30E+00 4.40E+00 WW 16 L5745-02 6/30/2003 Cs-134 1.00E-01 1.40E+00 4.90E+00 WW 16 L5745-02 6/30/2003 Cs-137
-3.10E+00 1.30E+00 4.90E+00 WW 16 L5745-02 6/30/2003 Fe-59
-3.60E+00 2.80E+00 1.90E+01 WW 16 L5745-02 6/30/2003 H-3 1.00E+02 4.00E+02 1.20E+03 WW 16 L5745-02 6/30/2003 I-131 2.60E+00 2.10E+00 7.10E+00 WW 16 L5745-02 6/30/2003 Mn-54 2.10E+00 1.20E+00 4.00E+00 WW 16 L5745-02 6/30/2003 Zn-65 7.30E+00 6.70E+00 2.20E+01 WW 16 L5745-02 6/30/2003 Zr-95 2.50E+00 2.30E+00 7.80E+00 WW 16 L6283-02 10/6/2003 Ba-140
-3.10E+00 2.50E+00 1.00E+01 WW 16 L6283-02 10/6/2003 Co-58 3.00E+00 2.00E+00 6.70E+00 WW 16 L6283-02 10/6/2003 Co-60
-1.60E+00 1.10E+00 4.60E+00 WW 16 L6283-02 10/6/2003 Cs-134
-2.10E+00 1.30E+00 5.20E+00 WW 16 L6283-02 10/6/2003 Cs-137
-2.30E+00 1.20E+00 4.60E+00 WW 16 L6283-02 10/6/2003 Fe-59
-4.00E-01 3.30E+00 1.20E+01 WW 16 L6283-02 10/6/2003 H-3
-2.50E+02 4.10E+02 1.30E+03 WW 16 L6283-02 10/6/2003 I-131 4.20E+00 4.50E+00 1.50E+01 WW 16 L6283-02 10/6/2003 Mn-54
-2.10E+00 1.20E+00 4.60E+00 WW 16 L6283-02 10/6/2003 Zn-65 6.20E+00 6.20E+00 2.10E+01 WW 16 L6283-02 10/6/2003 Zr-95 3.00E-01 2.20E+00 7.80E+00 WW 16 L4614-04 12/30/2002 Ba-140 0.00E+00 2.50E+00 9.30E+00 WW 16 L4614-04 12/30/2002 Co-58
-1.50E+00 1.40E+00 5.40E+00 WW 16 L4614-04 12/30/2002 Co-60 4.00E-01 1.70E+00 6.10E+00 WW 16 L4614-04 12/30/2002 Cs-134 1.70E+00 1.50E+00 5.00E+00 WW 16 L4614-04 12/30/2002 Cs-137 2.00E+00 1.50E+00 5.10E+00 WW 16 L4614-04 12/30/2002 Fe-59 4.90E+00 3.20E+00 1.10E+01 WW 16 L4614-04 12/30/2002 I-131 2.00E-01 3.00E+00 1.00E+01 WW 16 L4614-04 12/30/2002 Mn-54
-5.90E+00 1.60E+00 6.60E+00 WW 16 L4614-04 12/30/2002 Zn-65 6.80E+00 8.40E+00 2.80E+01 WW 16 L4614-04 12/30/2002 Zr-95
-2.40E+00 2.60E+00 9.50E+00