TABLE A-3.1 GAMMA SPECTROMETRY OF PARTICULATES FILTERS Results in pCi/cubic meter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY I 12/31/01 - 04/01/02 Be-7 6.57E-02 4.21 E-03 K-40

  • 3.01 E-03 2.24E-03 Ru-103 * - 2.88E-05 5.46E-04 Ru-106 *- 9.29E-04 1.64E-03 Cs-I 34 *- 2.50E-05 1.57E-04 Cs-1 37 *- 7.60E-05 8.66E-05 Ra-226
  • 1.58E-03 1.34E-03 04/01/02 - 07/01/02 Be-7 6.61 E-02 6.1 OE-03 K-40
  • 5.06E-03 4.71 E-03 Ru-1 03 *- 1.02E-04 5.83E-04 Ru-1 06
  • 3.02E-03 2.52E-03 Cs-1 34 * - 2.34E-04 2.1 OE-04 Cs-137 * - 1.42E-04 3.07E-04 Ra-226
  • 7.02E-04 3.12E-03 Th-228 * - 2.17E-04 4.94E-04 07/01/02 - 09/30/02 Be-7 7.46E-02 1.41 E-02 K-40
  • 1.39E-03 1.03E-02 Ru-1 03
  • 7.05E-04 1.01 E-03 Ru-106
  • 1.84E-03 4.32E-03 Cs-134
  • 4.69E-04 4.58E-04 Cs-1 37
  • 1.34E-03 9.29E-04 Th-228 * - 9.50E-04 7.1 OE-03 09/30/02 - 12/30/02 Be-7 3.47E-02 5.18E-03 K-40
  • 1.08E-03 5.12E-03 Ru-103
  • 1.17E-05 2.79E-04 Ru-106
  • 1.97E-04 2.03E-03 Cs-1 34
  • 1.08E-05 2.52E-04 Cs-1 37
  • 3.15E-03 4.67E-03
  • Denotes a result less than the detection limit.

TABLE A-3.1 (cont.)

GAMMA SPECTROMETRY OF PARTICULATES FILTERS Results in pCVcubic meter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 4 12/31101 - 04/01/02 Be-7 7.86E-02 5.11 E-03 K-40 * - 4.96E-04 2.16E-03 Ru-1 03 * - 3.52E-04 5.49E-04 Ru-I 06 * - 2.33E-04 1.81 E-03 Cs-134 * - 3.91 E-04 1.39E-04 Cs-1 37 * - 3.35E-05 1.86E-04 Ra-226

  • 1.07E-03 1.47E-03 04/01/02 - 07/01/02 Be-7 5.74E-02 4.54E-03 K-40
  • 3.18E-03 3.44E-03 Ru-1 03
  • 1.70E-04 5.49E-04 Ru-106 * - 8.90E-04 2.89E-03 Cs-1 34 * - 4.31E-04 3.28E-04 Cs-1 37
  • 1.08E-03 2.36E-03 Th-228 * - 6.09E-04 7.61 E-04 07/01/02 - 09/30/02 Be-7 6.93E-02 1.40E-02 K-40
  • 9.69E-03 4.35E-03 Ru-103 * - 1.45E-04 6.63E-04 Ru-1 06 * - 7.04E-04 2.33E-03 Cs-1 34
  • 1.97E-04 3.06E-04 Cs-1 37
  • 1.09E-03 4.22E-03 09/30/02 - 12/30/02 Be-7 3.30E-02 6.57E-03 K-40
  • 6.70E-03 7.52E-03 Ru-103 * - 2.79E-04 3.43E-04 Ru-106
  • 4.57E-06 2.67E-03 Cs-1 34 * - 1.13E-04 2.85E-04 Cs-1 37
  • 2.20E-04 3.08E-04 Ra-226 * - 2.30E-03 4.81 E-03 Th-228 * - 7.97E-03 4.73E-03
  • Denotes a result less than the detection limit.

TABLE A-3.1 (cont.)

GAMMA SPECTROMETRY OF PARTICULATES FILTERS Results in pCicubic meter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 5 12/31/01 - 04/01/02 Be-7 6.27E-02 4.59E-03 K-40

  • 9.13E-04 2.28E-03 Ru-1 03 *- 1.13E-04 6.28E-04 Ru-1 06 *- 9.52E-04 2.09E-03 Cs-134
  • 6.16E-04 1.49E-03 04/01/02 - 07/01/02 Be-7 6.32E-02 5.28E-03 K-40
  • 2.13E-03 3.32E-03 Ru-103 * - 2.80E-04 6.07E-04 Ru-106 * - 4.35E-04 2.89E-03 Cs-1 34
  • 6.47E-05 3.84E-04 Cs-1 37
  • 1.OOE-04 3.1OE-04 Ra-226 * - 2.85E-04 2.64E-03 Th-228 * - 5.44E-05 6.35E-04 07/01/02 - 09/30/02 Be-7 8.20E-02 1.22E-02 K-40
  • 5.01 E-03 5.44E-03 Ru-103
  • 1.33E-04 6.59E-04 Ru-106
  • 1.61 E-03 2.64E-03 Cs-1 34 * - 6.30E-04 2.80E-04 Cs-137 * - 2.68E-04 2.55E-04 Ra-226
  • 5.42E-03 1.02E-02 Th-228 * - 3.97E-03 6.16E-03 09/30/02 - 12/30/02 Be-7 3.01 E-02 7.66E-03 K-40
  • 1.81E-05 6.32E-03 Ru-103
  • 1.37E-05 4.OOE-04 Ru-106 * - 1.03E-03 3.11 E-03 Cs-134 * - 6.78E-04 3.50E-04 Cs-137
  • 1.30E-03 5.87E-03 Th-228 * - 1.57E-03 5.36E-03
  • Denotes a result less than the detection limit.

TABLE A-3.1 (cont.)

GAMMA SPECTROMETRY OF PARTICULATES FILTERS Results inpCi/cubic meter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 6 12/31/01 - 04/01/02 Be-7 6.72E-02 5.12E-03 K-40 *- 4.08E-05 3.63E-03 Ru-103

  • 6.85E-04 8.07E-04 Ru-106
  • 2.90E-04 2.48E-03 Cs-134 *- 2.09E-04 1.77E-04 Cs-1 37
  • 8.06E-04 1.79E-03 04/01/02 - 07/01/02 Be-7 6.21 E-02 6.30E-03 K-40
  • 6.92E-03 5.84E-03 Ru-1 03 *- 9.26E-04 8.92E-04 Ru-1 06 *- 1.42E-03 3.85E-03 Cs-I 34
  • 4.35E-04 6.73E-04 07/01/02 - 09/30/02 Be-7 7.56E-02 1.44E-02 K-40
  • 2.51 E-03 5.22E-03 Ru-103 * - 2.03E-05 9.1 OE-04 Ru-106 * - 1.71E-03 3.82E-03 Cs-134 * - 5.87E-04 4.12E-04 Cs-137 * - 1.13E-04 3.79E-04 Ra-226
  • 6.06E-03 7.33E-03 09/30/02 - 12/30/02 Be-7 4.62E-02 8.51 E-03 K-40
  • 1.59E-03 4.95E-03 Ru-103 * - 2.42E-04 4.52E-04 Ru-I 06 * - 1.30E-03 3.20E-03 Cs-134
  • 2.32E-03 7.14E-03

' Denotes a result less than the detection limit.

TABLE A-3.1 (cont.)

GAMMA SPECTROMETRY OF PARTICULATES FILTERS Results in pCi/cubic meter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 7 12/31/01 - 04/01/02 Be-7 6.94E-02 4.76E-03 K-40 * - 3.86E-03 2.90E-03 Ru-1 03

  • 3.01 E-04 7.19E-04 Ru-1 06 * - 1.74E-03 2.23E-03 Cs-1 34 * - 4.86E-04 3.01 E-04 Cs-1 37 * - 5.58E-05 1.07E-04 Ra-226 * - 3.14E-03 2.26E-03 Th-228 * - 2.35E-04 9.20E-04 04/01/02 - 07/01/02 Be-7 5.86E-02 5.36E-03 K-40
  • 1.30E-03 4.43E-03 Ru-I 03
  • 2.52E-04 7.86E-04 Ru-106
  • 2.15E-03 1.46E-03 Cs-1 34 * - 3.92E-04 5.25E-04 Cs-1 37
  • 4.21 E-04 3.94E-04 Ra-226 * - 2.25E-03 3.54E-03 Th-228 * - 5.89E-04 1.15E-03 07/01/02 - 09/30/02 Be-7 5.84E-02 1.06E-02 K-40 1.51 E-02 4.45E-03 Ru-103 * - 1.40E-04 5.84E-04 Ru-106 * - 1.95E-04 1.76E-03 Cs-1 34
  • 2.88E-05 1.76E-04 Cs-1 37
  • 2.02E-04 2.08E-04 Ra-226 * - 5.34E-03 3.75E-03 Th-228 * - 2.61E-03 3.37E-03 09/30/02 - 12/30/02 Be-7 4.34E-02 7.68E-03 K-40
  • 2.16E-03 5.02E-03 Ru-1 03
  • 2.74E-04 4.42E-04 Ru-I 06 *- 2.63E-03 2.93E-03 Cs-1 34 * - 3.54E-04 3.84E-04 Cs-1 37 * - 1.68E-04 3.87E-04 Ra-226 * - 4.07E-03 7.85E-03 Th-228
  • 5.77E-03 7.38E-03
  • Denotes a result less than the detection limit.

TABLE A-3.1 (cont.)

GAMMA SPECTROMETRY OF PARTICULATES FILTERS Results in pCilcubic meter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 8 12/31/01 - 04/01/02 Be-7 7.46E-02 5.33E-03 K-40

  • 2.97E-03 2.93E-03 Ru-1 03 *- 1.84E-04 7.79E-04 Ru-1 06
  • 7.26E-04 2.56E-03 Cs-134
  • 1.14E-04 1.62E-04 Cs-137 * - 3.35E-05 7.17E-05 Ra-226 * - 7.53E-03 6.95E-03 Th-228 * - 1.26E-03 1.42E-03 04/01/02 - 07/01/02 Be-7 6.40E-02 5.90E-03 K-40
  • 3.39E-03 4.47E-03 Ru-1 03
  • 3.98E-04 7.88E-04 Ru-106 * - 4.90E-05 3.84E-03 Cs-134 * - 1.91E-05 1.61 E-04 Cs-137
  • 5.02E-04 6.55E-04 07/01/02 - 09/30/02 Be-7 6.71 E-02 7.31 E-03 K-40
  • 6.39E-04 4.23E-03 Ru-1 03
  • 4.82E-04 7.24E-04 Ru-1 06 *- 8.61E-04 2.79E-03 Cs-1 34 *- 2.20E-04 3.27E-04 Cs-1 37
  • 5.45E-05 4.96E-04 09/30/02 - 12/30102 Be-7 4.73E-02 6.07E-03 K-40
  • 4.30E-03 4.09E-03 Ru-1 03
  • 1.71 E-05 3.25E-04 Ru-1 06 * - 1.36E-03 2.25E-03 Cs-134 * - 4.86E-04 2.61 E-04 Cs-137
  • 3.53E-03 8.31 E-03 Th-228 * - 8.75E-03 5.32E-03

' Denotes a result less than the detection limit.

TABLE A-3.1 (cont.)

GAMMA SPECTROMETRY OF PARTICULATES FILTERS Results in pCi/cubic meter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 9 12/31/01 - 04/01/02 Be-7 6.16E-02 4.54E-03 K-40

  • 1.61 E-04 2.48E-03 Ru-1 03
  • 1.20E-04 6.53E-04 Ru-106
  • 8.02E-04 2.11E-03 Cs-I 34
  • 2.22E-05 6.66E-05 Cs-1 37
  • 2.42E-03 1.61 E-03 04/01/02 - 07/01/02 Be-7 6.21 E-02 5.65E-03 K-40
  • 1.68E-03 3.72E-03 Ru-1 03
  • 1.62E-04 7.13E-04 Ru-1 06 1.37E-03 3.19E-03 Cs-134 *- 5.57E-05 4.39E-04 Cs-137
  • 1.73E-04 5.16E-04 07/01/02 - 09/30102 Be-7 6.33E-02 8.68E-03 K-40
  • 1.05E-04 7.97E-03 Ru-103 *- 1.87E-04 6.64E-04 Ru-106 * - 1.26E-03 2.71 E-03 Cs-134 * - 4.59E-04 3.06E-04 Cs-137 * - 2.29E-05 3.1 0E-04 Ra-226
  • 1.12E-04 7.72E-03 Th-228 * - 2.73E-03 4.90E-03 09/30/02 - 12/30/02 Be-7 2.94E-02 4.63E-03 K-40
  • 4.43E-03 5.90E-03 Ru-1 03
  • 4.23E-05 1.88E-04 Ru-I 06
  • 3.60E-04 1.54E-03 Cs-134
  • 2.08E-03 5.25E-03 Th-228 * - 1.82E-03 2.70E-03
  • Denotes a result less than the detection limit.

TABLE A-3.1 (cont.)

GAMMA SPECTROMETRY OF PARTICULATES FILTERS Results in pCi/cubic meter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 21 12131/01 - 04/01/02 Be-7 6.02E-02 4.04E-03 K-40

  • 2.89E-03 1.85E-03 Ru-1 03 *- 1.04E-04 3.69E-04 Ru-1 06
  • 1.14E-04 1.14E-03 Cs-134 * - 4.70E-05 8.24E-05 Cs-1 37 * - 7.11E-05 1.1 8E-04 Ra-226
  • 4.95E-05 1.44E-03 Th-228 * - 8.35E-05 1.02E-04 04/01/02 - 07/01/02 Be-7 6.24E-02 6.48E-03 K-40
  • 5.76E-03 4.04E-03 Ru-I 03
  • 5.72E-04 8.05E-04 Ru-i 06 *- 2.02E-03 4.23E-03 Cs-134 *- 2.60E-04 4.99E-04 Cs-1 37
  • 3.67E-05 5.55E-04 07/01/02 - 09/30102 Be-7 7.61 E-02 5.51 E-03 K-40
  • 3.55E-03 4.OOE-03 Ru-I03
  • 3.51 E-04 4.98E-04 Ru-106 * - 5.14E-05 1.93E-03 Cs-134
  • 8.81 E-04 3.63E-03 Th-228 * - 4.42E-03 3.62E-03 09/30/02 - 12/30/02 Be-7 4.07E-02 5.18E-03 K-40
  • 5.72E-03 5.44E-03 Ru-103
  • 2.02E-04 2.91 E-04 Ru-1 06 * - 7.71 E-04 2.20E-03 Cs-134
  • 2.24E-03 6.50E-03 Th-228 * - 1.07E-03 4.46E-03
  • Denotes a result less than the detection limit.

TABLE A-3.1 (cont.)

GAMMA SPECTROMETRY OF PARTICULATES FILTERS Results in pCi/cubic meter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 23 12/31/01 - 04/01/02 Be-7 6.02E-02 4.36E-03 K-40

  • 2.25E-03 2.31 E-03 Ru-1 03 * - 3.91E-04 4.55E-04 Ru-1 06 *- 2.91E-04 1.41 E-03 Cs-1 34 *- 3.12E-04 1.60E-04 Cs-1 37
  • 6.02E-0A 1.58E-03 Th-228 *- 4.76E-05 1.26E-04 04/01/02 - 07/01/02 Be-7 5.16E-02 5.48E-03 K-40 * - 1.72E-03 4.47E-03 Ru-103
  • 6.40E-05 8.53E-04 Ru-106 * - 3.59E-03 4.39E-03 Cs-134 * - 3.64E-04 5.73E-04 Cs-137 * - 8.02E-05 4.43E-04 Ra-226 * - 6.41E-04 3.64E-03 Th-228 * - 1.02E-03 1.40E-03 07/01/02 - 09/30/02 Be-7 6.96E-02 4.86E-03 K-40
  • 2.87E-03 3.37E-03 Ru-103 * - 3.06E-05 2.51 E-04 Ru-106 * - 4.06E-04 9.34E-04 Cs-1 34 * - 3.11E-05 1.03E-04 Cs-1 37 * - 5.33E-06 1.27E-04 Ra-226
  • 4.29E-04 2.99E-04 Th-228 * - 8.36E-03 1.87E-03 09/30/02 - 12/30/02 Be-7 3.50E-02 6.87E-03 K-40
  • 1.02E-03 6.17E-03 Ru-103 * - 4.98E-06 2.24E-04 Ru-106
  • 1.23E-03 1.95E-03 Cs-134 * - 4.55E-05 1.98E-04 Cs-137
  • 1.74E-04 2.10E-04 Ra-226 * - 1.97E-03 3.68E-03 Th-228 * - 4.49E-03 3.57E-03
  • Denotes a result less than the detection limit.

TABLE A-3.1 (cont.)

GAMMA SPECTROMETRY OF PARTICULATES FILTERS Results inpCVcubic meter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 40 12/31/01 - 04/01/02 Be-7 6.54E-02 4.53E-03 K-40 * - 2.15E-03 3.53E-03 Ru-1 03 * - 1.96E-04 5.17E-04 Ru-1 06

  • 1.09E-03 1.62E-03 Cs-1 34 * - 5.06E-05 1.1 5E-04 Cs-1 37 * - 1.90E-05 1.53E-04 Ra-226
  • 7.04E-06 1.74E-03 Th-228 * - 3.34E-04 2.48E-04 04/01/02 - 07/01/02 Be-7 6.29E-02 6.64E-03 K-40
  • 1.64E-03 4.93E-03 Ru-103 * - 6.04E-04 9.76E-04 Ru-106 * - 4.36E-03 5.21 E-03 Cs-134 * - 2.25E-04 3.57E-04 Cs-137
  • 2.05E-04 4.77E-04 Ra-226 * - 2.50E-03 3.68E-03 Th-228 * - 3.70E-06 7.26E-04 07/01/02 - 09/30/02 Be-7 6.26E-02 9.78E-03 K-40 1.64E-02 4.63E-03 Ru-103 * - 2.03E-04 4.15E-04 Ru-106
  • 4.62E-04 1.49E-03 Cs-134
  • 5.64E-06 1.87E-04 Cs-1 37
  • 1.51 E-04 6.16E-04 Th-228 * - 3.43E-03 3.OOE-03 09/30/02 - 12/30/02 Be-7 3.06E-02 2.96E-03 K-40
  • 1.02E-03 4.90E-03 Ru-103 * - 7.72E-05 2.24E-04 Ru-1 06 * - 2.53E-04 1.49E-03 Cs-1 34 * - 9.99E-04 1.89E-04 Cs-1 37
  • 3.74E-03 3.23E-03
  • Denotes a result less than the detection limit.

TABLE A-3.1 (cont.)

GAMMA SPECTROMETRY OF PARTICULATES FILTERS Results in pCilcubic meter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 48 12/31/01 - 04/01/02 Be-7 7.26E-02 4.63E-03 K-40

  • 4.73E-04 1.87E-03 Ru-1 03 * - 3.59E-04 3.77E-04 Ru-I 06 * - 9.16E-05 1.24E-03 Cs-1 34
  • 3.33E-05 9.07E-05 Cs-1 37
  • 9.80E-04 1.36E-03 Th-228 * - 4.01 E-05 1.09E-04 04/01/02 - 07/01/02 Be-7 5.47E-02 6.89E-03 K-40
  • 1.56E-03 6.37E-03 Ru-103 * - 5.99E-04 1.05E-03 Ru-106
  • 1.98E-03 4.41 E-03 Cs-1 34 * - 1.01E-03 6.38E-04 Cs-1 37
  • 4.34E-04 8.03E-04 07/01/02 - 09/30/02 Be-7 6.77E-02 8.18E-03 K-40 *- 7.29E-05 5.70E-03 Ru-1 03
  • 1.61E-04 6.59E-04 Ru-1 06 *- 1.23E-04 2.37E-03 Cs-134
  • 2.91 E-03 4.17E-03 09/30/02 - 12/30/02 Be-7 3.52E-02 2.73E-03 K-40
  • 8.74E-04 3.12E-03 Ru-103 * - 2.16E-05 1.86E-04 Ru-106 * - 1.48E-04 1.16E-03 Cs-134 * - 6.46E-04 1.67E-04 Cs-137
  • 4.76E-04 2.95E-03

' Denotes a result less than the detection limit.

TABLE A-3.1 (cont.)

GAMMA SPECTROMETRY OF PARTICULATES FILTERS Results in pCi/cubic meter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 57 12/31/01 - 04/01/02 Be-7 6.88E-02 5.OOE-03 K-40

  • 6.40E-04 2.91 E-03 Ru-1 03 * - 4.69E-04 5.57E-04 Ru-1 06
  • 5.22E-05 1.66E-03 Cs-1 34 * - 9.52E-06 1.25E-04 Cs-1 37
  • 2.29E-05 1.38E-04 04/01/02 - 07/01/02 Be-7 6.67E-02 5.76E-03 K-40
  • 2.24E-03 3.78E-03 Ru-1 03 * - 2.90E-04 5.07E-04 Ru-106 * - 6.80E-05 2.60E-03 Cs-1 34 * - 9.73E-05 1.97E-04 Cs-1 37
  • 1.06E-04 2.50E-04 Ra-226 * - 2.37E-03 2.67E-03 Th-228 * - 2.34E-04 4.83E-04 07/01/02 - 09/30/02 Be-7 7.20E-02 7.89E-03 K-40
  • 2.40E-04 5.68E-03 Ru-103 * - 4.22E-05 5.18E-04 Ru-106 * - 9.85E-04 2.05E-03 Cs-1 34 * - 1.95E-04 2.55E-04 Cs-1 37
  • 4.04E-03 4.27E-03 09/30/02 - 12/30/02 Be-7 3.40E-02 2.98E-03 K-40 * - 2.17E-02 3.09E-03 Ru-1 03 * - 5.37E-05 1.39E-04 Ru-1 06 * - 1.12E-03 9.88E-04 Cs-1 34
  • 6.84E-04 3.90E-03 Th-228 * - 8.81E-03 2.43E-03
  • Denotes a result less than the detection limit.

TABLE A-3.2 GAMMA SPECTROMETRY OF AIR PARTICULATES -

SUMMARY

Results in pCi/cubic meter NUMBER NUMBER NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE Be-7 (I) 5.91 E-02 3.01 E-02 8.20E-02 44 44 Be-7 (C) 5.41 E-02 2.94E-02 6.33E-02 4 4 K-40 (I) 2.23E-03 -2.17E-02 1.64E-02 44 2 K-40 (C) 1.59E-03 1.05E-04 4.43E-03 4 0 Ru-103 (I) -3.33E-05 -9.26E-04 7.05E-04 44 0 Ru-1 03 (C) 3.43E-05 -1.87E-04 1.62E-04 4 0 Ru-1 06 (I) -3.63E-04 -4.36E-03 3.02E-03 44 0 Ru-106 (C) 3.17E-04 -1.26E-03 1.37E-03 4 0 Cs-134 (I) -1.91 E-04 -1.01 E-03 4.69E-04 44 0 Cs-1 34 (C) -1.16E-04 -4.59E-04 2.71 E-05 4 0 Cs-137 (I) 6.23E-05 -2.68E-04 4.26E-04 44 0 Cs-137 (C) 9.23E-06 -1.17E-04 1.41 E-04 4 0 Ra-226 (I) 1.01 E-04 -7.53E-03 5.48E-03 44 0 Ra-226 (C) 1.54E-03 1.12E-04 2.52E-03 4 0 Th-228 (I) -5.91 E-04 -8.81 E-03 6.06E-03 44 0 Th-228 (C) -4.90E-04 -2.73E-03 2.42E-03 4 0 (I) Indicator Stations (C) Control Stations

TABLE A-4.1 1-131 IN CHARCOAL FILTERS Results in pCVcubic meter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 1 12/31/01 - 01/07/02 *- 3.99E-03 1.39E-02 01/07/02 - 01/14/02 - 2.37E-03 1.1 5E-02 01/14/02 - 01/21/02

  • 7.1 5E-03 1.27E-02 01/21/02 - 01/28/02
  • 3.71 E-04 1.43E-02 01/28/02 - 02/04/02
  • 6.20E-03 1.71 E-02 02/04/02 - 02/11/02
  • 5.82E-04 5.81 E-03 02/11/02 - 02/19/02
  • 4.88E-03 7.18E-03 02/19/02 - 02/25/02 *- 5.66E-03 9.18E-03 02/25/02 - 03/04/02
  • 1.96E-04 8.15E-03 03/04/02 - 03/11/02 * - 7.66E-03 1.04E-02 03/11/02 - 03/18/02
  • 1.16E-03 6.58E-03 03/18/02 - 03125/02
  • 2.03E-03 6.29E-03 03125/02 - 04/01/02 * - 3.33E-03 8.98E-03 04/01/02 - 04/08/02
  • 6.16E-03 1.1 3E-02 04/08/02 - 04/15/02
  • 6.46E-03 3.34E-02 04/15/02 - 04/22/02 * - 1.01E-02 2.02E-02 04/22/02 - 04/29/02 * - 3.89E-03 1.20E-02 04/29102 - 05106/02
  • 1.87E-03 2.92E-02 05/06/02 - 05/13/02 * - 4.07E-03 1.26E-02 05/13/02 - 05/20/02 * - 4.65E-03 6.71 E-03 05/20/02 - 05/28/02
  • 2.05E-03 1.97E-02 05/28/02 - 06/03/02
  • 1.27E-02 1.57E-02 06/03/02 - 06/10/02 * - 3.05E-02 2.03E-02 06/10/02 - 06/17/02
  • 1.31 E-03 3.1 5E-02 06117/02 - 06/24/02 * - 8.87E-03 8.49E-03 06124/02 - 07/01/02
  • 1.88E-03 6.90E-03 07/01/02 - 07108/02 * - 4.31E-03 7.24E-03 07/08/02 - 07/15/02 *- 3.49E-04 9.94E-03 07/15/02 - 07/22/02 *- 7.78E-03 8.41 E-03 07/22/02 - 07/29/02
  • 1.20E-02 1.37E-02 07/29/02 - 08/05/02
  • 6.37E-03 1.23E-02 08/05/02 - 08/12/02
  • 2.51 E-03 1.34E-02 08/12/02 - 08/19/02
  • 1.12E-02 1.03E-02 08/19/02 - 08/26/02 7.17E-04 8.15E-03 08/26102 - 09/03/02 *-6.35E-03 8.74E-03 09/03102 - 09109/02
  • 3.64E-03 1.17E-02 09/09102 - 09/16/02
  • 2.85E-03 9.51 E-03 09/16/02 - 09/23/02
  • 7.21 E-03 1.33E-02 09/23/02 - 09/30/02
  • 2.51 E-03 6.78E-03
  • Denotes a result less than the detection limit.

TABLE A-4.1 (cont.)

1-131 IN CHARCOAL FILTERS Results in pCUcubic meter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 1 09/30/02 10/07/02

  • 4.93E-03 1.31 E-02 10/07/02 10/14/02
  • 4.40E-03 1.77E-02 10/14/02 10/21/02
  • 1.50E-03 9.55E-03 10/21/02 10/28/02
  • 6.59E-04 8.82E-03 10/28/02 11/04/02
  • 7.56E-03 1.02E-02 11/04/02 11/11/02
  • 1.71 E-03 1.04E-02 11/11/02 11/18/02
  • 4.01E-03 9.87E-03 11/18/02 11/25/02 *- 3.49E-03 5.77E-03 11/25/02 12/02/02 *- 2.42E-03 2.75E-03 12/02/02 12/09/02 *- 5.42E-03 8.56E-03 12/09/02 12/16/02
  • 1.28E-03 1.71E-03 12/16/02 12/23/02 *- 5.92E-04 3.04E-03 12/23/02 12/30/02 *- 1.99E-03 8.91 E-03 4 12/31/01 - 01/07/02 * - 3.96E-03 1.38E-02 01/07/02 - 01/14/02 * - 2.54E-03 1.23E-02 01/14/02 - 01/21/02
  • 7.04E-03 1.25E-02 01/21/02 - 01/28/02
  • 3.66E-04 1.41 E-02 01/28/02 - 02/04/02
  • 6.11 E-03 1.69E-02 02/04/02 - 02/11/02
  • 5.71E-04 5.70E-03 02/11/02 - 02/19/02
  • 4.81E-03 7.07E-03 02/19/02 - 02/25/02 * - 5.03E-03 8.15E-03 02/25/02 - 03/04/02
  • 1.93E-04 8.03E-03 03/04/02 - 03/11/02 * - 7.56E-03 1.03E-02 03/11/02 - 03/18/02
  • 1.14E-03 6.49E-03 03/18/02 - 03/25/02
  • 2.OOE-03 6.20E-03 03/25/02 - 04/01/02 * - 3.28E-03 8.85E-03 04/01/02 - 04/08/02
  • 6.07E-03 1.12E-02 04/08/02 - 04/15/02
  • 3.44E-03 1.78E-02 04/15/02 - 04/22/02 * - 9.99E-03 1.99E-02 04/22/02 - 04/29/02 * - 3.83E-03 1.18E-02 04/29/02 - 05/06/02
  • 3.44E-04 5.37E-03 05/06/02 - 05/13/02 * - 4.02E-03 1.24E-02 05/13/02 - 05/20/02 * - 4.59E-03 6.61E-03 05/20/02 - 05/28/02
  • 2.02E-03 1.94E-02 05/28/02 - 06/03/02
  • 1.26E-02 1.54E-02 06/03/02 - 06/10/02 * - 2.99E-02 2.OOE-02 06/10/02 - 06/17/02
  • 1.31 E-03 3.14E-02 06/17/02 - 06/24/02 * - 8.75E-03 8.37E-03 06/24/02 - 07/01/02
  • 1.85E-03 6.81 E-03
  • Denotes a result less than the detection limit.

TABLE A-4.1 (cont.)

1-131 IN CHARCOAL FILTERS Results inpCi/cubic meter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 4 07/01/02 - 07/08/02 *- 4.66E-03 7.84E-03 07/08/02 - 07/15/02 *- 2.06E-04 5.85E-03 07/15/02 - 07/22/02 *- 7.67E-03 8.29E-03 07/22/02 - 07/29/02

  • 1.1 7E-02 1.34E-02 07/29/02 - 08/05/02
  • 6.28E-03 1.21E-02 08/05/02 - 08/12/02
  • 2.47E-03 1.32E-02 08/12/02 - 08/19/02
  • 1.10E-02 1.01E-02 08/19102 - 08126102 *- 5.26E-04 5.98E-03 08/26/02 - 09/03/02 *- 6.16E-04 5.56E-03 09/03/02 - 09109/02
  • 3.59E-03 1.16E-02 09/09/02 - 09/16102
  • 2.81E-03 9.40E-03 09/16/02 - 09/23102
  • 7.08E-03 1.31 E-02 09/23/02 - 09/30/02
  • 2.48E-03 6.70E-03 09130/02 10/07/02
  • 4.83E-03 1.28E-02 10/07/02 10/14/02
  • 4.34E-03 1.75E-02 10/14/02 10/21/02
  • 1.48E-03 9.40E-03 10/21/02 10/28/02
  • 6.51E-04 8.72E-03 10/28/02 11/04/02
  • 7.43E-03 1.OOE-02 11/04/02 11/11/02
  • 1.68E-03 1.03E-02 11/11/02 11/18/02
  • 3.94E-03 9.72E-03 11/18/02 11/25/02 * - 3.43E-03 5.68E-03 11/25/02 12/02/02 * - 2.38E-03 2.71E-03 12/02/02 12/09102 * - 5.34E-03 8.44E-03 12/09/02 12/16/02
  • 1.26E-03 1.68E-03 12/16102 12/23102 * - 5.83E-04 2.99E-03 12/23102 12/30/02 * - 1.97E-03 8.82E-03 5 12/31/01 - 01/07/02 * - 3.96E-03 1.38E-02 01/07/02 - 01/14/02 * - 2.34E-03 1.14E-02 01/14/02 - 01/21/02
  • 7.08E-03 1.26E-02 01/21/02 - 01/28/02
  • 3.67E-04 1.41 E-02 01/28/02 - 02/04/02
  • 6.13E-03 1.70E-02 02/04/02 - 02/11/02
  • 5.74E-04 5.73E-03 02/11/02 - 02/19/02
  • 4.83E-03 7.1OE-03 02/19/02 - 02/25/02 * - 5.05E-03 8.18E-03 02/25/02 - 03/04/02
  • 1.94E-04 8.07E-03 03/04/02 - 03/11/02 * - 7.60E-03 1.04E-02 03/11/02 - 03/18/02
  • 1.15E-03 6.52E-03 03/18/02 - 03/25/02
  • 2.01E-03 6.23E-03 03/25/02 - 04/01/02 * - 3.29E-03 8.89E-03
  • Denotes a result less than the detection limit.

TABLE A-4.1 (cont.)

1-131 IN CHARCOAL FILTERS Results inpCVcubic meter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 5 04/01/02 - 04/08/02

  • 6.10E-03 1.12E-02 04/08/02 - 04/15/02
  • 6.39E-03 3.31E-02 04/15/02 - 04/22/02 * - 7.81 E-03 1.55E-02 04/22/02 - 04/29/02 * - 3.85E-03 1.19E-02 04/29/02 - 05/06/02
  • 3.44E-04 5.38E-03 05/06/02 - 05/13/02 * - 3.20E-03 9.90E-03 05/13/02 - 05/20/02 * - 4.61 E-03 6.64E-03 05/20/02 - 05/28/02
  • 2.03E-03 1.95E-02 05/28/02 - 06/03/02
  • 7.55E-03 9.27E-03 06/03/02 - 06/10/02 * - 3.01 E-02 2.01 E-02 06/10/02 - 06/17/02
  • 1.31E-03 3.14E-02 06/17/02 - 06/24/02 * - 5.86E-03 5.61 E-03 06/24/02 - 07/01/02
  • 1.86E-03 6.84E-03 07/01/02 - 07/08/02 * - 4.26E-03 7.17E-03 07/08/02 - 07/15/02 * - 3.46E-04 9.84E-03 07/15/02 - 07/22/02 * - 7.70E-03 8.32E-03 07/22/02 - 07/29/02
  • 6.20E-03 7.08E-03 07/29/02 - 08/05/02
  • 6.31 E-03 1.22E-02 08/05/02 - 08/12/02
  • 2.48E-03 1.32E-02 08/12/02 - 08/19/02
  • 7.34E-03 6.79E-03 08/19/02 - 08/26/02 * - 7.11E-04 8.08E-03 08/26/02 - 09/03/02
  • 7.19E-03 9.56E-03 09/03/02 - 09/09/02
  • 3.61 E-03 1.16E-02 09/09/02 - 09/16/02
  • 3.27E-03 1.11E-02 09/16/02 - 09/23/02
  • 7.13E-03 1.32E-02 09/23/02 - 09/30/02
  • 2.49E-03 6.73E-03 09/30/02 10/07/02
  • 4.87E-03 1.29E-02 10/07/02 10/14/02
  • 4.36E-03 1.75E-02 10/14/02 10/21/02
  • 1.48E-03 9.45E-03 10/21/02 10/28/02
  • 6.52E-04 8.73E-03 10/28/02 11/04/02
  • 7.46E-03 1.01E-02 11/04/02 11/11/02
  • 1.26E-03 7.67E-03 11/11/02 11/18/02
  • 3.96E-03 9.76E-03 11/18/02 11/25/02 * - 3.45E-03 5.71E-03 11/25/02 12/02/02 * - 2.39E-03 2.72E-03 12/02/02 12/09/02 * - 5.37E-03 8.47E-03 12/09/02 12/16/02
  • 1.26E-03 1.69E-03 12/16/02 12/23/02 * - 5.86E-04 3.01 E-03 12/23/02 12/30/02 * - 1.97E-03 8.84E-03
  • Denotes a result less than the detection limit.

TABLE A-4.1 (cont.)

1-131 IN CHARCOAL FILTERS Results in pCVcubic meter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 6 12131/01 - 01/07/02 * - 3.98E-03 1.39E-02 01/07/02 - 01/14/02 *- 2.36E-03 1.14E-02 01/14/02 - 01/21/02

  • 7.13E-03 1.27E-02 01/21/02 - 01/28/02
  • 3.70E-04 1.42E-02 01/28102 - 02104/02
  • 6.18E-03 1.71 E-02 02/04102 - 02/11/02
  • 5.80E-04 5.79E-03 02/11/02 - 02/19/02
  • 4.87E-03 7.1 6E-03 02/19/02 - 02/25102 * - 5.09E-03 8.25E-03 02/25/02 - 03/04102
  • 1.96E-04 8.13E-03 03/04/02 - 03/11/02 - 7.66E-03 1.04E-02 03/11/02 - 03/18/02
  • 1.15E-03 6.57E-03 03/18/02 - 03/25/02
  • 1.16E-03 3.60E-03 03/25/02 - 04/01102 * - 3.32E-03 8.96E-03 04/01/02 - 04/08/02
  • 6.15E-03 1.1 3E-02 04/08102 - 04/15/02
  • 6.44E-03 3.33E-02 04115/02 - 04/22/02 * - 1.01E-02 2.01 E-02 04/22/02 - 04/29/02 * - 3.88E-03 1.20E-02 04/29/02 - 05/06/02
  • 3.48E-04 5.44E-03 05106/02 - 05/13/02 *- 4.38E-03 1.35E-02 05/13/02 - 05120/02 *- 1.72E-03 2.49E-03 05/20/02 - 05128/02 2.05E-03 1.97E-02 05/28/02 - 06/03/02
  • 1.27E-02 1.56E-02 06/03/02 - 06/10102 *- 3.04E-02 2.03E-02 06/10/02 - 06/17/02
  • 1.31 E-03 3.14E-02 06/17/02 - 06/24/02 *- 8.86E-03 8.48E-03 06/24/02 - 07/01/02 *1.88E-03 6.89E-03 07/01/02 - 07/08/02 - 4.30E-03 7.23E-03 07/08/02 - 07/15/02 *- 3.48E-04 9.92E-03 07/15/02 - 07/22/02 - 7.76E-03 8.39E-03 07/22/02 - 07/29/02 *1. 19 E-02 1.36E-02 07/29/02 - 08/05/02
  • 6.36E-03 1.23E-02 08/05/02 - 08/12102
  • 2.50E-03 1.33E-02 08/12/02 - 08/19102
  • 1.11E-02 1.03E-02 08/19/02 - 08126/02 - 7.14E-04 8.11E-03 08/26/02 - 09/03/02 *- 9.50E-04 8.58E-03 09/03/02 - 09/09/02
  • 3.64E-03 1.1 7E-02 09/09/02 - 09/16/02 * - 1.16E-02 1.24E-02 09/16/02 - 09/23/02
  • 7.19E-03 1.33E-02 09/23102 - 09/30/02
  • 2.51 E-03 6.79E-03
  • Denotes a result less than the detection limit.

TABLE A-4.1 (cont.)

1-131 IN CHARCOAL FILTERS Results in pCiVcubic meter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 6 09/30/02 10/07/02

  • 4.91 E-03 1.31 E-02 10/07/02 10/14/02
  • 4.40E-03 1.77E-02 10/14/02 10/21/02
  • 1.50E-03 9.53E-03 10/21/02 10/28/02
  • 6.57E-04 8.80E-03 10/28/02 11/04/02
  • 7.55E-03 1.02E-02 11/04/02 11/11/02
  • 1.70E-03 1.04E-02 11/11/02 11/18/02
  • 4.OOE-03 9.85E-03 11/18/02 11/25/02 * - 3.48E-03 5.75E-03 11/25/02 12/02/02 * - 2.41E-03 2.74E-03 12/02/02 12/09/02 * - 5.41 E-03 8.54E-03 12/09/02 12/16/02
  • 1.28E-03 1.71 E-03 12/16/02 12/23/02 * - 5.90E-04 3.03E-03 12/23/02 12/30/02 * - 1.99E-03 8.91 E-03 7 12/31/01 - 01/07/02
  • 3.42E-03 1.25E-02 01/07/02 - 01/14/02
  • 1.08E-03 8.27E-03 01/14/02 - 01/21/02 *- 1.44E-03 6.87E-03 01/21/02 - 01/28/02 * - 3.02E-03 1.77E-02 01/28/02 - 02/04/02 * - 7.49E-04 6.82E-03 02/04/02 - 02/11/02 *- 1.17E-03 5.75E-03 02/11/02 - 02/19/02
  • 3.80E-03 7.62E-03 02/19/02 - 02/25/02 * - 4.21 E-03 7.57E-03 02/25/02 - 03/04/02
  • 5.19E-03 6.20E-03 03/04/02 - 03/11/02 * - 7.37E-03 9.08E-03 03/11/02 - 03/18/02
  • 7.27E-04 4.14E-03 03/18/02 - 03/25/02
  • 2.02E-03 6.29E-03 03/25/02 - 04/01/02 * - 4.43E-04 7.15E-03 04/01/02 - 04/08/02
  • 4.62E-03 8.19E-03 04/08/02 - 04/15/02
  • 6.45E-03 3.33E-02 04/15/02 - 04/22102
  • 1.01E-02 2.02E-02 04/22/02 - 04/29/02 *- 417E-03 1.39E-02 04/29/02 - 05/06/02
  • 2.84E-03 1.34E-02 05/06/02 - 05/13/02 *- 4.07E-03 1.26E-02 05/13/02 - 05/20/02 *- 4.65E-03 6.70E-03 05120/02 - 05/28/02
  • 3.97E-03 3.81 E-02 05/28/02 - 06/03/02
  • 1.27E-02 1.56E-02 06/03/02 - 06/10/02
  • 1.23E-02 2.34E-02 06/10/02 - 06/17/02
  • 8.35E-04 2.01 E-02 06/17/02 - 06/24/02 *- 8.87E-03 8.49E-03 06/24/02 - 07/01/02
  • 1.18E-03 4.34E-03
  • Denotes a result less than the detection limit.

TABLE A-4.1 (cont.)

1-131 IN CHARCOAL FILTERS Results inpCUcubic meter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 7 07/01/02 - 07/08/02 * - 2.87E-03 4.83E-03 07/08/02 - 07/15/02 * - 3.49E-04 9.94E-03 07/15/02 - 07/22/02 * - 4.09E-03 4.42E-03 07/22/02 - 07/29/02

  • 1.20E-02 1.37E-02 07/29/02 - 08/05/02
  • 4.34E-04 1.1 5E-02 08/05/02 - 08/12/02
  • 1.20E-03 6.41 E-03 08/12/02 - 08/19/02
  • 1.12E-02 1.03E-02 08/19/02 - 08/26102 * - 7.15E-04 8.13E-03 08/26/02 - 09/03/02 * - 9.52E-04 8.59E-03 09/03/02 - 09/09/02
  • 9.56E-04 1.27E-02 09/09/02 - 09/16/02
  • 2.85E-03 9.51 E-03 09116/02 - 09/23/02
  • 4.53E-03 8.35E-03 09123/02 - 09/30/02 * - 5.12E-03 1.91 E-02 09/30/02 10/07/02
  • 3.OOE-03 7.97E-03 10/07/02 10/14/02
  • 2.77E-03 1.11 E-02 10/14/02 10/21/02
  • 8.27E-04 5.27E-03 10/21/02 10/28/02
  • 5.06E-04 6.78E-03 10/28/02 11/04/02
  • 5.75E-03 7.76E-03 11/04/02 11/11/02
  • 1.18E-03 7.21 E-03 11/11/02 11/18/02
  • 3.06E-03 7.53E-03 11/18/02 11/25/02 * - 2.47E-03 4.08E-03 11/25/02 12/02/02 * - 2.42E-03 2.75E-03 12/02/02 12/09102 * - 5.42E-03 8.55E-03 12/09/02 12/16/02
  • 1.28E-03 1.71 E-03 12/16/02 12/23/02 * - 5.91E-04 3.04E-03 12/23/02 12/30/02
  • 4.86E-04 9.19E-03 8 12/31/01 - 01/07/02
  • 3.39E-03 1.24E-02 01/07/02 - 01/14/02
  • 1.08E-03 8.28E-03 01/14/02 - 01/21/02 *- 1.42E-03 6.80E-03 01/21/02 - 01/28/02 * - 2.99E-03 1.75E-02 01/28/02 - 02/04/02 *- 7.41 E-04 6.75E-03 02/04/02 - 02/11/02 * - 1.16E-03 5.68E-03 02/11/02 - 02/19/02
  • 3.76E-03 7.54E-03 02/19/02 - 02/25/02 * - 4.17E-03 7.49E-03 02/25/02 - 03/04/02
  • 5.14E-03 6.14E-03 03/04/02 - 03/11/02 * - 3.76E-03 9.07E-03 03/11/02 - 03/18/02 * - 8.13E-03 6.39E-03 03/18/02 - 03/25/02
  • 3.19E-04 5.61 E-03 03/25/02 - 04/01/02 * - 4.38E-04 7.08E-03

' Denotes a result less than the detection limit.

TABLE A-4.1 (cont.)

1-131 IN CHARCOAL FILTERS Results in pCVcubic meter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 8 04/01/02 - 04108/02

  • 4.57E-03 8.1 OE-03 04/08/02 - 04/15/02 *- 2.32E-02 2.71 E-02 04/15/02 - 04/22/02 * - 2.33E-03 2.36E-02 04/22/02 - 04/29/02 * - 4.13E-03 1.37E-02 04/29/02 - 05/06/02
  • 2.81 E-03 1.32E-02 05/06/02 - 05/13/02 * - 6.86E-04 1.25E-02 05/13/02 - 05/20/02 * - 7.26E-03 8.1 2E-03 05/20/02 - 05/28/02
  • 4.06E-03 6.37E-03 05/28/02 - 06/03/02 * - 3.63E-03 1.59E-02 06/03/02 - 06/10/02
  • 1.22E-02 2.32E-02 06/10/02 - 06/17/02 *- 2.12E-02 2.25E-02 06/17102 - 06/24/02 * - 4.50E-03 1.09E-02 06/24/02 - 07/01/02 * - 3.62E-03 6.64E-03 07/01/02 - 07108/02
  • 3.35E-03 6.41 E-03 07/08/02 - 07/15/02 * - 3.45E-04 9.84E-03 07/15/02 - 07/22/02 * - 2.14E-03 7.20E-03 07/22/02 - 07/29/02 * - 8.16E-03 8.95E-03 07/29/02 - 08/05/02
  • 4.30E-04 1.14E-02 08/05/02 - 08/12/02 *- 1.15E-02 1.50E-02 08112/02 - 08/19/02
  • 1.11E-02 1.28E-02 08/19/02 - 08/26/02 *- 8.10E-04 1.15E-02 08/26/02 - 09/03/02 *- 6.02E-03 8.29E-03 09/03/02 - 09/09/02
  • 9.46E-04 1.26E-02 09109/02 - 09/16/02 *- 1.15E-02 1.23E-02 09/16/02 - 09/23/02
  • 3.68E-03 1.33E-02 09/23/02 - 09/30/02 *- 5.07E-03 1.89E-02 09/30/02 10/07/02
  • 4.15E-03 6.77E-03 10/07/02 10/14/02
  • 2.70E-04 1.03E-02 10/14/02 10/21/02
  • 4.56E-03 8.47E-03 10/21/02 10/28/02
  • 1.38E-04 9.22E-03 10/28/02 11/04/02 * - 3.51 E-06 7.20E-03 11/04/02 11/11/02 *- 6.61 E-03 8.39E-03 11/11/02 11/18/02 *- 1.18E-03 7.76E-03 11/18/02 11/25/02
  • 1.01E-03 4.88E-03 11/25/02 12/02/02
  • 5.14E-04 2.16E-03 12/02/02 12/09/02 *- 2.31E-04 3.86E-03 12/09/02 12/16/02 *- 1.64E-03 2.16E-03 12/16/02 12/23/02
  • 1.86E-03 2.20E-03 12/23/02 12/30/02
  • 4.81 E-04 9.10E-03
  • Denotes a result less than the detection limit.

TABLE A-4.1 (cont.)

1-131 IN CHARCOAL FILTERS Results in pCVcubic meter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 9 12/31/01 - 01/07/02 *3.41 E-03 1.25E-02 01/07/02 - 01/14/02

  • 1.08E-03 8.23E-03 01/14/02 - 01/21/02 *- 1.02E-03 4.87E-03 01/21/02 - 01/28/02 * - 3.01 E-03 1.76E-02 01/28/02 - 02/04/02 * - 7.45E-04 6.79E-03 02/04/02 - 02/11/02 *- 1.16E-03 5.70E-03 02/11/02 - 02/19/02
  • 3.78E-03 7.58E-03 02/19/02 - 02/25/02 * - 4.19E-03 7.53E-03 02/25/02 - 03/04/02
  • 5.17E-03 6.17E-03 03/04/02 - 03/11/02 * - 3.78E-03 9.12E-03 03/11/02 - 03/18/02 * - 8.17E-03 6.42E-03 03/18/02 - 03/25/02
  • 3.20E-04 5.64E-03 03/25/02 - 04/01/02 * - 4.41 E-04 7.11E-03 04/01/02 - 04/08/02
  • 4.59E-03 8.14E-03 04/08/02 - 04/15/02 * - 1.78E-02 2.08E-02 04/15/02 - 04/22/02 *- 2.34E-03 2.36E-02 04/22/02 - 04/29/02 * - 4.15E-03 1.38E-02 04/29/02 - 05/06/02
  • 2.82E-03 1.33E-02 05/06/02 - 05/13/02 *- 6.87E-04 1.26E-02 05/13/02 - 05/20/02 *- 7.30E-03 8.16E-03 05/20/02 - 05/28/02
  • 4.08E-03 6.40E-03 05/28/02 - 06/03/02 *- 3.63E-03 1.60E-02 06/03/02 - 06/10/02
  • 1.23E-02 2.33E-02 06/10/02 - 06/17/02 *- 2.12E-02 2.26E-02 06/17/02 - 06/24/02 *- 4.50E-03 1.09E-02 06/24/02 - 07/01/02 *- 3.63E-03 6.68E-03 07/01/02 - 07/08/02
  • 3.36E-03 6.44E-03 07/08/02 - 07/15/02
  • 2.32E-03 1.29E-02 07/15/02 - 07/22/02 * - 2.15E-03 7.24E-03 07/22/02 - 07/29/02 * - 1.31E-02 1.44E-02 07/29/02 - 08/05/02
  • 4.32E-04 1.1 5E-02 08/05/02 - 08/12/02 *- 1.16E-02 1.51 E-02 08/12/02 - 08/19/02
  • 1.12E-02 1.29E-02 08/19/02 - 08/26/02 * - 8.1 OE-04 1.15E-02 08/26/02 - 09/03/02 * - 6.06E-03 8.33E-03 09/03/02 - 09/09/02
  • 9.51 E-04 1.26E-02 09/09/02 - 09/16/02
  • 3.29E-03 1.11E-02 09/16/02 - 09/23/02
  • 3.70E-03 1.34E-02 09/23/02 - 09/30/02 *- 5.10E-03 1.90E-02
  • Denotes a result less than the detection limit.

TABLE A-4.1 (cont.)

1-131 IN CHARCOAL FILTERS Results in pCVcubic meter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 9 09/30/02 10/07/02

  • 4.18E-03 6.81 E-03 10/07/02 10/14/02
  • 2.71 E-04 1.03E-02 10/14/02 10/21/02
  • 4.58E-03 8.52E-03 10/21/02 10/28/02
  • 1.39E-04 9.24E-03 10/28/02 11/04/02 - 8.01 E-06 1.65E-02 11/04/02 11/11/02 *- 6.65E-03 8.44E-03 11/11/02 11/18/02 *- 1.19E-03 7.82E-03 11/18/02 11/25/02
  • 1.01 E-03 4.90E-03 11/25/02 12/02/02
  • 5.17E-04 2.17E-03 12/02/02 12/09/02 * - 2.32E-04 3.88E-03 12/09/02 12/16/02 * - 1.66E-03 2.18E-03 12/16/02 12/23/02
  • 1.87E-03 2.21 E-03 12/23/02 12/30/02
  • 4.84E-04 9.14E-03 21 12/31/01 - 01/07/02
  • 3.43E-03 1.25E-02 01/07/02 - 01/14/02
  • 1.08E-03 8.29E-03 01/14/02 - 01/21/02 *- 1.44E-03 6.88E-03 01/21/02 - 01/28/02 * - 3.04E-03 1.78E-02 01/28/02 - 02/04/02 * - 7.51 E-04 6.84E-03 02/04/02 - 02/11/02 *- 1.17E-03 5.76E-03 02/11/02 - 02/19/02
  • 3.81 E-03 7.64E-03 02/19/02 - 02/25/02 * - 4.22E-03 7.59E-03 02/25/02 - 03/04/02
  • 5.20E-03 6.22E-03 03/04/02 - 03/11/02 * - 3.81 E-03 9.19E-03 03/11/02 - 03/18/02 * - 8.22E-03 6.47E-03 03/18/02 - 03/25/02
  • 3.23E-04 5.68E-03 03/25/02 - 04/01/02 * - 4.44E-04 7.17E-03 04/01/02 - 04/08/02
  • 4.63E-03 8.20E-03 04/08/02 - 04/15/02 * - 2.35E-02 2.74E-02 04/15/02 - 04/22/02 *- 2.36E-03 2.38E-02 04/22/02 - 04/29/02 *- 4.18E-03 1.39E-02 04/29/02 - 05/06/02
  • 2.84E-03 1.34E-02 05/06/02 - 05/13/02 *- 6.92E-04 1.27E-02 05/13/02 - 05/20/02 *- 7.35E-03 8.22E-03 05/20/02 - 05/28/02
  • 4.1 1 E-03 6.45E-03 05/28/02 - 06/03/02 *- 3.66E-03 1.61 E-02 06/03/02 - 06/10/02
  • 1.26E-02 2.39E-02 06/10/02 - 06/17/02 *- 1.89E-02 2.01 E-02 06/17/02 - 06/24/02 *- 4.55E-03 1.1 0E-02 06/24/02 - 07/01/02 * - 3.66E-03 6.72E-03
  • Denotes a result less than the detection limit.

TABLE A-4.1 (cont.)

1-131 IN CHARCOAL FILTERS Results in pCVcubic meter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 21 07/01/02 - 07/08102

  • 3.39E-03 6.49E-03 07108/02 - 07/15/02
  • 2.33E-03 1.29E-02 07/15/02 - 07/22/02 *- 2.16E-03 7.29E-03 07/22/02 - 07/29/02 *- 1.32E-02 1.44E-02 07/29/02 - 08/05/02
  • 2.60E-04 6.89E-03 08/05/02 - 08/12/02 * - 1.16E-02 1.52E-02 08/12/02 - 08/19/02
  • 1.13E-02 1.30E-02 08/19/02 - 08/26102 *- 5.41E-04 7.60E-03 08/26/02 - 09/03/02 *- 9.54E-04 8.61 E-03 09/03/02 - 09/09/02
  • 5.84E-04 7.77E-03 09/09/02 - 09/16/02 *- 1.16E-02 1.25E-02 09/16/02 - 09/23/02
  • 3.72E-03 1.35E-02 09/23/02 - 09/30/02 *- 5.14E-03 1.91 E-02 09/30/02 10/07/02
  • 4.28E-03 6.98E-03 10/07/02 10/14/02
  • 2.73E-04 1.04E-02 10/14/02 10/21/02
  • 4.62E-03 8.58E-03 10/21/02 10/28/02
  • 1.40E-04 9.31 E-03 10/28/02 11/04/02 * - 4.23E-06 8.69E-03 11/04/02 11/11/02 - 6.70E-03 8.50E-03 11/11/02 11/18/02 *- 1.20E-03 7.89E-03 11/18/02 11/25/02
  • 1.02E-03 4.94E-03 11/25/02 12/02/02
  • 5.20E-04 2.19E-03 12/02/02 12/09/02 * - 2.34E-04 3.91 E-03 12/09/02 12/16/02 * - 1.67E-03 2.19E-03 12/16/02 12/23/02
  • 1.88E-03 2.23E-03 12/23/02 12/30/02
  • 4.86E-04 9.19E-03 23 12/31/01 - 01/07/02
  • 1.17E-02 2.34E-02 01/07/02 - 01/14/02 * - 6.78E-03 9.25E-03 01/14/02 - 01/21/02 * - 1.44E-03 6.88E-03 01/21/02 - 01/28/02 * - 3.23E-02 2.37E-02 01/28/02 - 02/04/02 *- 1.26E-03 7.49E-03 02/04/02 - 02/111/02 * - 3.67E-03 6.93E-03 02/11/02 - 02/19/02 - 5.26E-03 1.06E-02 02/19/02 - 02/25/02 - 2.59E-03 5.04E-03 02/25/02 - 03/04/02
  • 2.88E-03 6.22E-03 03/04/02 - 03/11/02 - 3.81E-03 9.18E-03 03/11/02 - 03/18/02 - 8.22E-03 6.46E-03 03/18/02 - 03/25/02 3.23E-04 5.67E-03 03/25/02 - 04/01/02 * - 4.03E-04 7.35E-03
  • Denotes a result less than the detection limit.

TABLE A-4.1 (cont.)

1-131 IN CHARCOAL FILTERS Results in pCi/cubic meter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 23 04/01/02 - 04/08/02 *- 3.93E-03 6.92E-03 04/08102 - 04/15/02 *- 2.35E-02 2.74E-02 04/15/02 - 04/22/02 *- 2.35E-03 2.38E-02 04/22/02 - 04/29/02

  • 1.34E-03 1.32E-02 04/29/02 - 05/06/02
  • 3.01 E-03 7.48E-03 05/06/02 - 05/13/02 *- 6.92E-04 1.27E-02 05/13/02 - 05/20/02 *- 7.35E-03 8.21 E-03 05/20/02 - 05/28/02
  • 4.11E-03 6.44E-03 05/28/02 - 06/03102 *- 3.66E-03 1.61 E-02 06/03/02 - 06/10/02
  • 8.13E-03 1.55E-02 06/10/02 - 06/17/02 *- 2.13E-02 2.26E-02 06/17/02 - 06/24/02 *- 4.55E-03 1.1 OE-02 06/24/02 - 07/01/02 *- 3.66E-03 6.72E-03 07/01/02 - 07/08/02
  • 3.39E-03 6.49E-03 07/08/02 - 07/15/02
  • 2.33E-03 1.29E-02 07/15/02 - 07/22/02 * - 2.16E-03 7.28E-03 07/22/02 - 07/29/02 *- 1.32E-02 1.44E-02 07/29/02 - 08/05/02
  • 4.35E-04 1.1 5E-02 08/05/02 - 08/12/02 *- 6.12E-03 7.97E-03 08/12/02 - 08/19/02
  • 1.12E-02 1.30E-02 08/19/02 - 08/26/02 * - 8.20E-04 1.1 6E-02 08/26/02 - 09/03/02
  • 3.79E-04 5.08E-03 09/03/02 - 09/09/02
  • 9.57E-04 1.27E-02 09/09/02 - 09/16/02
  • 2.85E-03 9.53E-03 09/16/02 - 09/23/02
  • 3.72E-03 1.35E-02 09/23/02 - 09/30/02 *- 5.01E-03 1.47E-02 09/30/02 10/07/02
  • 4.21 E-03 6.86E-03 10/07/02 10/14/02
  • 2.73E-04 1.04E-02 10/14/02 10/21/02
  • 4.62E-03 8.58E-03 10/21/02 10/28/02
  • 1.40E-04 9.30E-03 10/28/02 11/04/02 * - 3.56E-06 7.31 E-03 11/04/02 11/11/02 * - 6.70E-03 8.49E-03 11/11/02 11/18/02 *- 1.20E-03 7.86E-03 11/18/02 11/25/02
  • 1.02E-03 4.94E-03 11/25/02 12/02/02
  • 9.56E-04 4.02E-03 12/02/02 12/09/02 * - 2.34E-04 3.91 E-03 12/09/02 12/16/02 * - 1.67E-03 2.19E-03 12/16/02 12/23/02
  • 1.88E-03 2.22E-03 12/23/02 12/30/02 * - 5.68E-03 4.68E-03
  • Denotes a result less than the detection limit.

TABLE A-4.1 (cont.)

1-131 IN CHARCOAL FILTERS Results inpCilcubic meter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 40 12/31/01 - 01/07/02

  • 7.54E-03 1.51 E-02 01/07/02 - 01/14/02 - 6.71 E-03 9.15E-03 01114/02 - 01/21102 * - 5.92E-03 6.39E-03 01/21/02 - 01/28/02 *- 1.77E-02 1.29E-02 01/28/02 - 02/04/02 *- 1.25E-03 7.41 E-03 02/04/02 - 02/11/02 * - 3.62E-03 6.84E-03 02/11/02 - 02/19/02 * - 5.21 E-03 1.05E-02 02/19/02 - 02/25/02 * - 3.61 E-03 7.02E-03 02/25/02 - 03/04/02
  • 2.85E-03 6.16E-03 03/04/02 - 03111/02 * - 4.36E-03 5.37E-03 03/11/02 - 03/18/02
  • 1.26E-03 6.92E-03 03/18/02 - 03/25/02
  • 2.21E-04 6.52E-03 03/25/02 - 04/01/02 * - 3.99E-04 7.28E-03 04/01/02 - 04/08/02 * - 3.89E-03 6.85E-03 04/08/02 - 04/15/02 *- 2.33E-02 2.71 E-02 04/15/02 - 04/22/02 *- 1.22E-03 1.24E-02 04/22/02 - 04/29/02
  • 1.33E-03 1.31 E-02 04/29/02 - 05/06/02
  • 2.97E-03 7.38E-03 05/06/02 - 05/13/02
  • 7.54E-05 1.OOE-02 05/13/02 - 05/20/02
  • 4.47E-03 9.45E-03 05/20/02 - 05/28/02
  • 1.04E-02 9.47E-03 05/28/02 - 06/03/02
  • 1.16E-03 1.79E-02 06/03/02 - 06/10/02
  • 6.62E-03 1.35E-02 06/10/02 - 06/17/02 *- 1.OOE-02 2.33E-02 06/17/02 - 06/24/02 *- 3.61E-03 7.08E-03 06/24/02 - 07/01/02 * - 2.56E-03 4.70E-03 07/01/02 - 07/08/02
  • 2.62E-03 5.01 E-03 07/08/02 - 07/15/02 *- 6.67E-03 1.29E-02 07/15/02 - 07/22/02 *- 1.57E-03 5.29E-03 07/22/02 - 07/29/02 *- 1.30E-02 1.43E-02 07/29/02 - 08/05/02 *- 1.41 E-02 1.56E-02 08/05/02 - 08/12/02 *- 1.15E-02 1.50E-02 08/12/02 - 08/19/02 *- 7.61E-04 7.11 E-03 08/19/02 - 08/26/02 *- 8.1OE-04 1.1 5E-02 08/26/02 - 09/03/02
  • 7.19E-03 9.57E-03 09/03/02 - 09/09/02 *- 1.25E-02 1.65E-02 09/09/02 - 09/16/02
  • 1.45E-03 4.86E-03 09/16/02 - 09/23/02
  • 2.55E-03 9.23E-03 09/23/02 - 09/30/02 *- 495E-03 1.46E-02

' Denotes a result less than the detection limit.

TABLE A-4.1 (cont.)

1-131 IN CHARCOAL FILTERS Results in pCi/cubic meter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 40 09/30/02 10/07/02

  • 1.57E-03 1.12E-02 10/07/02 10114/02
  • 1.52E-04 5.79E-03 10/14/02 10/21/02 * - 4.30E-04 4.52E-03 10/21/02 10/28/02
  • 6.96E-03 1.20E-02 10/28/02 11/04/02 * - 2.70E-06 5.54E-03 11/04102 11/11/02
  • 7.60E-04 1.17E-02 11/11/02 11/18/02 * - 1.07E-03 7.01 E-03 11/18/02 11/25/02
  • 1.75E-04 7.03E-03 11/25/02 12/02/02
  • 5.15E-04 2.16E-03 12/02/02 12/09/02 * - 1.90E-03 2.1 3E-03 12/09/02 12/16/02 * - 1.65E-03 2.16E-03 12/16/02 12/23/02
  • 1.86E-03 2.20E-03 12/23/02 12/30/02 * - 5.63E-03 4.64E-03 48 12/31/01 - 01/07/02
  • 1.16E-02 2.32E-02 01/07/02 - 01/14/02 * - 6.69E-03 9.13E-03 01/14/02 - 01/21/02 * - 5.91E-03 6.38E-03 01/21/02 - 01/28/02 * - 3.19E-02 2.33E-02 01/28/02 - 02/04/02 * - 1.25E-03 7.40E-03 02/04102 - 02/11/02 * - 1.90E-03 3.59E-03 02/11/02 - 02/19/02 * - 2.86E-03 5.75E-03 02/19/02 - 02/25/02 * - 3.60E-03 7.01 E-03 02/25/02 - 03/04/02
  • 2.84E-03 6.15E-03 03/04/02 - 03/11102 * - 7.29E-03 8.98E-03 03/11/02 - 03/18/02
  • 1.26E-03 6.91 E-03 03/18/02 - 03/25/02
  • 2.20E-04 6.51 E-03 03/25/02 - 04/01/02 * - 3.98E-04 7.26E-03 04/01/02 - 04108/02 *- 3.57E-03 6.29E-03 04/08/02 - 04/15/02
  • 9.35E-03 2.70E-02 04/15/02 - 04/22/02 *- 4.38E-03 1.97E-02 04/22/02 - 04/29/02
  • 1.33E-03 1.30E-02 04/29/02 - 05/06/02
  • 2.96E-03 7.37E-03 05/06/02 - 05/13/02
  • 7.52E-05 9.98E-03 05113102 - 05120/02
  • 4.46E-03 9.42E-03 05/20102 - 05/28/02
  • 1.04E-02 9.45E-03 05/28/02 - 06/03/02
  • 1.15E-03 1.79E-02 06/03/02 - 06/10/02
  • 6.60E-03 1.34E-02 06/10102 - 06/17102 *- 1.00E-02 2.33E-02 06/17/02 - 06/24/02 - 3.60E-03 7.06E-03 06/24/02 - 07/01/02 *- 1.06E-03 4.88E-03
  • Denotes a result less than the detection limit.

TABLE A-4.1 (cont.)

1-131 IN CHARCOAL FILTERS Results inpCi/cubic meter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 48 07/01/02 - 07/08/02

  • 1.23E-03 3.36E-03 07/08102 - 07/15/02 * - 6.66E-03 1.29E-02 07/15/02 - 07/22/02 * - 8.92E-03 7.93E-03 07/22/02 - 07/29102
  • 3.16E-03 9.40E-03 07/29/02 - 08/05/02 *- 1.41E-02 1.56E-02 08/05/02 - 08/12/02 * - 5.16E-03 1.41 E-02 08/12/02 - 08/19/02 * - 7.55E-04 7.06E-03 08/19/02 - 08/26/02 * - 3.33E-03 1.34E-02 08/26/02 - 09/03/02
  • 7.18E-03 9.54E-03 09/03/02 - 09/09102 * - 1.25E-02 1.64E-02 09/09/02 - 09/16/02
  • 3.27E-03 1.11E-02 09/16/02 - 09/23/02 * - 6.01 E-03 1.78E-02 09/23/02 - 09/30/02 * - 4.94E-03 1.46E-02 09130/02 10/07/02
  • 1.43E-03 7.20E-03 10/07/02 10/14/02
  • 5.41 E-03 6.15E-03 10/14/02 10/21/02 * - 4.29E-04 4.51 E-03 10/21/02 10/28/02
  • 6.94E-03 1.1 9E-02 10/28/02 11/04/02 * - 2.54E-03 6.34E-03 11/04/02 11/11/02
  • 7.58E-04 1.17E-02 11/11/02 11/18/02
  • 1.40E-03 8.50E-03 11/18/02 11/25/02
  • 1.75E-04 7.02E-03 11/25102 12/02/02
  • 6.48E-04 4.98E-03 12/02102 12/09/02 *- 1.89E-03 2.1 3E-03 12/09/02 12/16/02 * - 9.79E-04 2.37E-03 12/16/02 12/23/02
  • 1.73E-03 3.29E-03 12/23/02 12/30/02 * - 5.62E-03 4.63E-03 57 12/31/01 - 01/07/02
  • 1.17E-02 2.34E-02 01/07/02 - 01/14/02 * - 5.44E-03 7.41 E-03 01/14/02 - 01/21/02 * - 5.99E-03 6.47E-03 01/21/02 - 01/28/02 * - 3.24E-02 2.37E-02 01/28/02 - 02/04/02 * - 6.65E-04 3.94E-03 02/04/02 - 02/11/02 * - 3.68E-03 6.94E-03 02/11/02 - 02/19/02 * - 5.36E-03 1 .08E-02 02/19/02 - 02/25/02 * - 3.65E-03 7.11 E-03 02/25/02 - 03/04/02
  • 2.88E-03 6.23E-03 03/04/02 - 03/11/02 * - 7.39E-03 9.1 OE-03 03/11/02 - 03/18/02
  • 1.33E-03 7.31 E-03 03/18/02 - 03/25/02
  • 2.23E-04 6.60E-03 03125/02 - 04/01/02 * - 4.03E-04 7.36E-03
  • Denotes a result less than the detection limit.

TABLE A-4.1 (cont.)

1-131 IN CHARCOAL FILTERS Results inpCVcubic meter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 57 04/01/02 - 04/08/02 *- 3.93E-03 6.93E-03 04/08/02 - 04/15/02

  • 7.52E-03 2.17E-02 04/15/02 - 04/22/02 - 444E-03 2.OOE-02 04/22/02 - 04/29/02
  • 1.34E-03 1.32E-02 04/29/02 - 05/06/02
  • 3.01 E-03 7.49E-03 05/06/02 - 05/13/02
  • 7.61 E-05 1.01 E-02 05/13/02 - 05/20/02
  • 4.53E-03 9.56E-03 05/20/02 - 05/28/02
  • 8.64E-02 7.86E-02 05/28/02 - 06/03/02
  • 1.17E-03 1.81 E-02 06/03/02 - 06/10/02
  • 6.73E-03 1.37E-02 06/10/02 - 06117/02 *- 9.63E-03 2.24E-02 06/17/02 - 06/24/02 * - 3.65E-03 7.16E-03 06/24/02 - 07/01102 * - 1.07E-03 4.95E-03 07/01102 - 07/08/02
  • 1.25E-03 3.41 E-03 07/08/02 - 07/15/02 * - 6.73E-03 1.30E-02 07/15/02 - 07/22/02 *- 9.05E-03 8.04E-03 07/22/02 - 07/29/02
  • 2.25E-03 6.69E-03 07/29/02 - 08/05/02 *- 1.43E-02 1.58E-02 08/05/02 - 08/12/02 - 3.73E-03 1.02E-02 08/12/02 - 08/19/02 *- 7.70E-04 7.20E-03 08/19/02 - 08/26/02 *- 3.37E-03 1.35E-02 08/26/02 - 09/03/02 * - 9.55E-04 8.62E-03 09/03/02 - 09/09/02 * - 1.27E-02 1.67E-02 09/09/02 - 09/16/02
  • 3.31 E-03 1.12E-02 09/16/02 - 09/23/02 *- 6.11E-03 1.81 E-02 09/23/02 - 09/30/02 * - 5.01 E-03 1.48E-02 09/30/02 10/07/02
  • 1.46E-03 7.36E-03 10/07/02 10/14/02
  • 5.47E-03 6.21 E-03 10/14/02 10/21/02 - 4.36E-04 4.58E-03 10/21/02 10/28/02 *7.02E-03 1.21 E-02 10/28/02 11/04/02 * - 2.58E-03 6.45E-03 11/04/02 11/11/02
  • 7.70E-04 1.18 E-02 11/11/02 11/18/02
  • 1.42E-03 8.64E-03 11/18/02 11/25/02
  • 1.77E-04 7.12E-03 11/25/02 12/02/02
  • 6.57E-04 5.05E-03 12/02/02 12/09/02 *- 1.92E-03 2.16E-03 12/09/02 12/16/02 *- 1.83E-03 4.43E-03 12/16/02 12/23/02
  • 1.76E-03 3.34E-03 12/23/02 12/30/02 * - 5.69E-03 4.69E-03
  • Denotes a result less than the detection limit.

TABLE A-4.2 1-131 CHARCOAL FILTERS -

SUMMARY

Results in pCVcubic meter NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE -

1-131 (I) 4.I1 E-03 -6.70E-03 8.64E-02 572 0 1-131 (C) 3.71 E-03 -6.65E-03 2.12E-02 52 0 (I) Indicator Stations (C) Control Stations

TABLE A-5.1 GROSS BETA IN WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY River/Drinkina 26 01/02/02 - 02/05/02 1.1OE+00 7.OOE-01 02/05/02 - 03/05/02

  • 9.60E-01 7.49E-01 03/05/02 - 04/02/02 1.40E+00 7.OOE-01 04/02/02 - 05/07/02 9.90E+00 1.71 E+00 05/07/02 - 06/04/02 2.44E+00 7.13E-01 06/04/02 - 07/02/02
  • 1.52E-01 1.17E+00 07/02/02 - 08/06/02
  • 9.89E-01 1.12E+00 08/06/02 - 09/04/02
  • 1.31 E+00 1.13E+00 09/03/02 - 10/01/02
  • 1.53E+00 1.11 E+00 10/01/02 11/05/02
  • 1.61 E+00 1.84E+00 11/05/02 12/03/02 2.17E+00 1.09E+00 12/03102 01/02/03
  • 1.59E+00 1.82E+00 29 01/02/02 - 02/05/02 2.20E+00 8.00E-01 02/05/02 - 03/05/02
  • 6.40E-01 7.41 E-01 03/05/02 - 04/02/02 1.60E+00 7.OOE-01 04/02/02 - 05/07/02 5.11 E+00 1.03E+00 05/07/02 - 06/04/02 1.31 E+00 6.23E-01 06/04/02 - 07/02102
  • 6.59E-01 1.21 E+00 07/02/02 - 08/06/02
  • 4.42E-01 1.06E+00 08/06/02 - 09/04/02
  • 1.57E+00 1.15E+00 09/03/02 - 10/01/02
  • 1.31 E+00 1.1OE+00 10/01/02 11/05/02
  • 1.16E+00 1.82E+00 11/05/02 12/03/02 2.76E+00 1.14E+00 12/03/02 01/02/03
  • 8.39E-01 1.77E+00 Discharge 27 01/02/02 - 02/05/02 8.70E+00 1.50E+00 02/05/02 - 03/05/02 1.OOE+01 2.OOE+00 03/05/02 - 04/02/02 1.30E+01 2.OOE+00 04/02/02 - 05/07/02 8.72E+00 1.60E+00 05/07/02 - 06104/02 1.1OE+01 1.64E+00 06/04/02 - 07/02/02 5.19E+00 2.12E+00 07/02/02 - 08/06/02 4.99E+00 1.76E+00 08/06/02 - 09/04/02 8.40E+00 2.13E+00 09/03/02 - 10/01/02 9.44E+00 2.15E+00 10/01/02 11/05/02 7.56E+00 2.88E+00 11/05/02 12/03/02 1.07E+01 2.1 OE+00 12/03/02 01/02/03 9.84E+00 2.80E+00
  • Denotes a result less than the detection limit.

TABLE A-5.2 GROSS BETA IN WATER -

SUMMARY

Results in pCUcubic liter NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE RiverlDrinkinq Gr-Beta (I) 1.63E+00 4.42E-01 5.11E+00 12 5 Br-Beta (C) 2.1OE+00 1.52E-01 9.90E+00 12 5 Discharge Gr-Beta (I) 8.96E+00 4.99E+00 1.30E+01 12 12 (I) Indicator Stations (C) Control Stations

TABLE A-6.1 TRITIUM IN WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY River/Drinking 26 1/2/2002 - 4/2/2002

  • 7.04E+00 6.22E+01 4/2/2002 - 7/2/2002 1.55E+02 8.25E+01 7/2/2002 - 10/1/2002
  • 4.05E+01 1.02E+02 10/1/2002 1/2/2003
  • 9.38E+01 9.51E+01 29 1/2/2002 - 4/2/2002
  • 1.89E+01 6.29E+01 4/2/2002 - 7/2/2002
  • 1.17E+02 7.74E+01 7/2/2002 - 10/1/2002
  • 1.45E+02 1.04E+02 10/1/2002 1/2/2003 1.32E+02 7.83E+01 Discharge 27 1/3/2001 - 4/3/2001 1.04E+02 6.60E+01 4/2/2002 - 7/2/2002 1.63E+02 8.07E+01 7/2/2002 - 10/1/2002 2.12E+02 1.11E+02 10/1/2002 1/2/2003 2.37E+02 1.27E+02 Ground 31 (Well 1) 3/5/2002
  • 3.43E+01 6.16E+01 6/4/2002 * - 1.1 E+01 6.01E+01 9/4/2002
  • 8.25E+01 7.96E+01 12/3/2002 * - 9.05E+01 1.47E+02 32 (well 2) 3/5/2002
  • 1.13E+01 5.98E+01 6/4/2002
  • 1.33E+01 6.07E+01 9/4/2002
  • 3.65E+01 8.07E+01 12/3/2002 * - 8.32E+01 1.63E+02 52 3/5/2002
  • 8.11 E+01 6.24E+01 (well 3) 6/4/2002
  • 5.80E+01 6.26E+01 9/4/2002
  • 5.84E+01 8.13E+01 12/3/2002
  • 9.48E+00 1.72E+02
  • Denotes a result less than the detection limit.

TABLE A-6.2 TRITIUM IN WATER -

SUMMARY

Results in pCVcubic liter NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE River/Drinkinq H-3 (I) 1.03E+02 1.89E+01 1.45E+02 4 1 H-3 (C) 7.41 E+01 7.04E+00 1.55E+02 4 1 Discharge H-3 (I) 1.79E+02 1.04E+02 2.37E+02 4 4 Ground H-3 (I) 4.75E+01 9.48E+00 9.05E+01 12 0 (I) Indicator Stations (C) Control Stations

TABLE A-7.1 GAMMA SPECTROMETRY OF WATER Results In pCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY River/Drinking 26 01/02/02 - 02/05/02 Be-7

  • 2.56E+00 1.18E+01 K-40
  • 6.42E+00 1.45E+01 Mn-54 * - 1.34E+00 1.11E+00 Co-58 *- 3.74E-01 1.34E+00 Fe-59
  • 2.53E+00 2.81 E+00 Co-60 *- 7.25E-01 1.14E+00 Zn-65 *- 1.07E+00 1.89E+00 Nb-95
  • 1.62E-01 1.20E+00 Zr-95
  • 1.94E-01 1.97E+00 Cs-1 34
  • 1.41 E-02 8.56E-01 Cs-1 37
  • 7.01 E-02 1.02E+00 Ba-140 * - 3.13E+00 1.33E+01 La-140
  • 3.29E+01 1.80E+01 Th-228 * - 2.48E+00 2.44E+00 02/05/02 - 03/05/02 Be-7 * - 1.36E+01 1.96E+01 K-40
  • 1.63E+00 1.76E+00 Co-58 * - 3.14E-01 1.24E+00 Fe-59
  • 1.08E+00 1.64E+00 Zn-65 * - 4.22E+00 2.71 E+00 Nb-95
  • 1.80E+00 1.84E+00 Zr-95 * - 6.83E-01 3.30E+00 Cs-1 34 * - 6.85E-01 1.93E+00 Cs-1 37
  • 2.82E-01 1.67E+00 Ba-140 * - 4.25E+00 1.90E+01 La-140
  • 8.92E+00 1.28E+01 03/05/02 - 04/02/02 Be-7
  • 2.12E+01 1.67E+01 K-40 * - 9.56E+00 2.14E+01 Mn-54
  • 2.77E-01 1.91 E+00 Co-58 * - 2.80E-01 1.99E+00 Fe-59
  • 1.15E+00 3.62E+00 Co-60 * - 7.58E-01 1.89E+00 Zn-65 * - 3.43E+00 4.06E+00 Nb-95 * - 5.40E-02 1.72E+00 Zr-95
  • 3.08E+00 2.83E+00 Cs-134 * - 9.02E-01 1.44E+00 Cs-137 * - 1.07E+00 1.93E+00 Ba-140 * - 7.54E+00 1.14E+01 La-140
  • 7.89E+00 2.79E+01 Th-228 * - 1.08E+00 1.77E+00
  • Denotes a result less than the detection limit.

TABLE A-7.1 (cont.)

GAMMA SPECTROMETRY OF WATER Results in pCiAiter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY River/Drinkinn 26 04/02/02 - 05/07/02 Be-7

  • 5.27E+00 1.96E+01 K-40
  • 2.55E+01 2.40E+01 Mn-54 * - 6.09E-01 2.25E+00 Co-58
  • 1.68E+00 2.12E+00 Fe-59
  • 1.86E-01 1.89E+00 Zn-65 * - 2.57E+00 5.32E+00 Nb-95 * - 1.44E+00 1.96E+00 Zr-95
  • 9.29E-01 3.17E+00 Cs-1 34 * - 2.38E+00 2.13E+00 Cs-137
  • 9.33E-01 2.04E+00 Ba-140
  • 1.15E+00 1.04E+01 La-140 * - 1.44E+00 3.48E+00 Ra-226 * - 1.98E+01 2.34E+01 Th-228 * - 2.85E+00 3.89E+00 05/07/02 - 06/04/02 Be-7
  • 2.53E+01 2.62E+01 K-40
  • 1.40E+00 2.73E+00 Co-58 *- 3.47E+00 2.99E+00 Fe-59
  • 1.24E+00 5.74E+00 Co-60 * - 8.15E-01 2.90E+00 Zn-65 * - 1.84E+00 4.25E+00 Nb-95
  • 2.08E+00 2.59E+00 Zr-95 * - 9.60E-02 1.90E+00 Cs-1 34 * - 1.33E+01 3.54E+00 Cs-1 37
  • 1.34E+00 2.65E+00 Ba-140 * - 1.51E+00 1.54E+01 La-140
  • 2.92E+00 4.66E+00 Ra-226 * - 1.38E+01 2.96E+01 Th-228 * - 1.86E+01 2.01 E+01 06/04/02 - 07/02/02 Be-7
  • 1.60E+01 2.26E+01 K-40
  • 1.14E+01 3.08E+01 Mn-54 * - 1.66E-01 1.95E+00 Co-58
  • 6.26E-01 2.77E+00 Fe-59
  • 4.95E+00 5.26E+00 Co-60 *- 2.34E+00 2.44E+00 Zn-65 *- 1.89E-01 3.46E+00 Nb-95
  • 8.27E-01 2.25E+00 Zr-95
  • 1.27E+00 4.16E+00 Cs-134
  • 2.88E+00 2.46E+00 Ba-140 *- 4.58E+00 1.29E+01 La-140
  • 3.24E+00 3.88E+00 Ra-226 *- 1.67E+01 2.87E+01 Th-228 *- 3.49E+00 1.85E+01
  • Denotes a result less than the detection limit.

TABLE A-7.1 (cont.)

GAMMA SPECTROMETRY OF WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY River/Drinkina 26 07/02/02 - 08/06/02 Be-7 *- 8.50E+00 1.21 E+01 K-40 *- 3.09E+01 1.40E+01 Mn-54 *- 1.75E-01 1.26E+00 Co-58 * - 5.14E-01 1.32E+00 Fe-59

  • 1.62E-01 1.23E+00 Zn-65
  • 6.76E-01 1.85E+00 Nb-95 *-6.21 E-01 1.18E+00 Zr-95
  • 3.24E-01 1.92E+00 Cs-134 * -6.71 E-01 9.09E-01 Cs-137
  • 6.62E-01 7.60E-01 Ba-140
  • 2.95E+00 7.01 E+00 La-140
  • 4.69E+00 1.90E+01 Th-228 *- 1.53E+00 2.41 E+00 08/06/02 09/04/02 Be-7
  • 2.29E+00 1.95E+01 K-40 * - 6.20E+00 1.84E+01 Mn-54 * - 3.55E-01 1.53E+00 Co-58
  • 1.01E+00 1.11E+00 Fe-59
  • 4.73E-01 1.66E+00 Zn-65 * - 2.28E-01 1.68E+00 Nb-95
  • 1.57E+00 1.80E+00 Zr-95 * - 2.92E+00 3.25E+00 Cs-134 * - 8.65E+00 2.OOE+00 Cs-1 37
  • 1.45E+00 1.60E+00 Ba-140
  • 7.90E-02 2.03E+01 La-140
  • 1.32E+01 1.98E+01 Th-228 *- 3.51E+00 2.47E+00 09/03/02 10/01/02 Be-7 * - 1.23E+00 8.13E+00 K-40
  • 1.33E+01 1.09E+01 Mn-54 * - 4.60E-01 7.93E-01 Co-58
  • 6.90E-02 8.88E-01 Fe-59 * - 1.20E-01 1.85E+00 Co-60
  • 1.36E-01 7.91 E-01 Zn-65 * - 4.62E-01 1.17E+00 Nb-95
  • 9.1OE-01 8.22E-01 Zr-95
  • 4.80E-01 1.38E+00 Cs-134 * - 8.57E-01 7.21 E-01 Cs-137 - 4.68E-01 6.76E-01 Ba-140
  • 1.85E+00 6.81 E+00 La-140 * - 1.20E+00 2.36E+00 Ra-226
  • 1.26E+01 1.25E+01 Th-228 *- 2.92E+00 1.82E+00

' Denotes a result less than the detection limit.

TABLE A-7.1 (cont.)

GAMMA SPECTROMETRY OF WATER Results in pCilliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY RiverlDrinking 26 10/01102 - 11/05/02 Be-7 *- 7.61E+00 1.30E+01 K-40 *- 2.48E+01 1.46E+01 Mn-54 * - 7.05E-01 1.26E+00 Co-58 * - 1.95E-01 1.39E+00 Fe-59

  • 1.40E+00 2.76E+00 Co-60 * - 5.34E-01 1.13E+00 Zn-65
  • 2.47E-01 1.62E+00 Nb-95
  • 1.09E-01 1.20E+00 Zr-95
  • 8.80E-02 2.19E+00 Cs-134
  • 6.30E-01 1.24E+00 Ba-140
  • 6.84E+00 9.41 E+00 La-140 * - 1.95E+00 3.25E+00 Ra-226 * - 1.07E+01 1.63E+01 Th-228 * - 3.67E-01 2.61 E+00 11105/02 - 12/03/02 Be-7
  • 2.38E+01 3.12E+01 K-40
  • 2.82E+01 9.05E+01 Mn-54 * - 1.03E-01 3.69E+00 Co-58 * - 5.13E-01 3.86E+00 Fe-59
  • 3.24E+00 7.92E+00 Co-60 * - 5.69E-01 3.51 E+00 Zn-65
  • 4.67E+00 8.67E+00 Nb-95
  • 3.92E+00 3.97E+00 Zr-95
  • 2.12E+00 6.71 E+00 Cs-134 * - 1.73E+01 3.98E+00 Cs-1 37
  • 1.66E-01 3.87E+00 Ba-140
  • 1.20E+01 1.83E+01 La-140 * - 1.87E+00 6.13E+00 Ra-226
  • 2.26E+01 7.08E+01 12/03/02 - 01/02/03 Be-7
  • 3.24E-01 7.54E+00 K-40 * - 1.16E+01 2.13E+01 Mn-54 * - 9.03E-02 8.47E-01 Co-58
  • 6.11E-01 8.21 E-01 Fe-59 * - 7.20E-01 1.75E+00 Co-60
  • 8.75E-02 8.28E-01 Zn-65 * - 4.90E-01 1.80E+00 Nb-95
  • 1.72E-01 8.84E-01 Zr-95
  • 5.29E-01 1.42E+00 Cs-134 * - 7.09E-02 8.14E-01 Cs-1 37 * - 1.38E-01 8.89E-01 Ba-140
  • 4.76E-01 3.69E+00 La-140 * - 2.76E-01 1.22E+00 Ra-226
  • 5.31 E+00 4.52E+01 Th-228 * - 2.44E+01 2.15E+01
  • Denotes a result less than the detection limit.

TABLE A-7.1 (cont.)

GAMMA SPECTROMETRY OF WATER Results in pCiliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY River/Drinking 29 01/02/02 - 02/05/02 Be-7

  • 3.85E+00 1.35E+01 K-40
  • 8.29E-01 1.28E+00 Co-58 * - 5.29E-01 1.48E+00 Fe-59
  • 9.49E-01 1.16E+00 Zn-65
  • 2.09E-01 2.06E+00 Nb-95
  • 1.50E+00 1.28E+00 Zr-95 * - 9.20E-01 2.34E+00 Cs-I 34 * - 3.57E+00 1.42E+00 Cs-I 37
  • 1.35E+00 1.11 E+00 Ba-140 * - 8.88E+00 1.53E+01 La-140
  • 1.24E+01 1.76E+01 Th-228 * - 1.73E+00 1.25E+00 02/05/02 - 03/05/02 Be-7 * - 1.15E+00 2.14E+01 K-40
  • 1.25E+00 2.01 E+00 Co-58 * - 1.24E+00 2.29E+00 Fe-59
  • 1.41 E+00 4.76E+00 Co-60 * - 8.97E-01 1.83E+00 Zn-65 * - 1.27E+00 2.41 E+00 Nb-95
  • 1.51 E+00 2.05E+00 Zr-95
  • 2.23E+00 3.62E+00 Cs-i 34
  • 1.56E+00 2.06E+00 Cs-137 * - 1.18E+00 1.84E+00 Ba-140
  • 1.21E+01 2.04E+01 La-140 * - 3.93E-01 6.48E+00 Ra-226 * - 7.75E+01 2.65E+01 Th-228
  • 7.24E+00 1.39E+01 03/05/02 - 04/02/02 Be-7
  • 2.55E+00 2.33E+01 K-40 * - 6.20E+01 4.28E+01 Mn-54
  • 1.26E+00 2.52E+00 Co-58 * - 1.34E+00 2.65E+00 Fe-59
  • 4.32E+00 5.36E+00 Co-60 * - 2.68E-01 2.53E+00 Zn-65 * - 7.07E+00 6.88E+00 Nb-95
  • 1.31E+00 2.47E+00 Zr-95
  • 1.75E-01 4.42E+00 Cs-134 * - 6.50E-02 1.60E+00 Cs-137 * - 2.95E-01 2.48E+00 Ba-140 * - 4.53E+00 1.42E+01 La-140
  • 4.53E-01 2.35E+00
  • Denotes a result less than the detection limit.

TABLE A-7.1 (cont.)

GAMMA SPECTROMETRY OF WATER Results in pCiliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY RiverlDrinking 29 04/02/02 - 05/07/02 Be-7

  • 7.35E+00 2.16E+01 K-40 * - 5.19E+00 3.08E+01 Mn-54
  • 5.81 E-01 2.41 E+00 Co-58
  • 1.21E+00 2.61 E+00 Fe-59 * - 1.77E-01 4.75E+00 Co-60
  • 1.44E+00 2.13E+00 Zn-65 * - 5.30E+00 4.53E+00 Nb-95
  • 2.32E+00 2.29E+00 Zr-95
  • 3.50E+00 3.61 E+00 Cs-1 34
  • 1.45E-01 1.63E+00 Cs-1 37
  • 1.82E+00 2.44E+00 Ba-140
  • 4.03E+00 1.24E+01 La-140 * - 9.48E-01 4.41 E+00 Ra-226
  • 2.82E-02 1.95E+00 05/07/02 - 06/04/02 Be-7 * - 7.86E+00 1.92E+01 K-40 * - 2.20E-01 2.46E+01 Mn-54 * - 5.97E-01 1.98E+00 Co-58 * - 1.25E+00 2.31 E+00 Fe-59
  • 4.78E-01 3.92E+00 Co-60 * - 6.97E-01 2.OOE+00 Zn-65
  • 4.40E-01 3.38E+00 Nb-95
  • 3.56E-01 2.02E+00 Zr-95
  • 1.71 E+00 3.16E+00 Cs-134 *- 8.53E-01 1.34E+00 Cs-1 37 * - 8.10E-02 1.89E+00 Ba-140 * - 1.08E+00 1.14E+01 La-140
  • 2.98E+00 3.92E+00 06/04/02 - 07/02/02 Be-7
  • 1.11 E+01 2.42E+01 K-40
  • 6.71 E-01 2.35E+00 Co-58 * - 3.72E-01 2.80E+00 Fe-59
  • 4.78E+00 5.60E+00 Co-60 * - 8.50E-02 2.68E+00 Zn-65 * - 1.95E-01 *1.50E+00 Nb-95
  • 2.63E+00 2.40E+00 Zr-95 * - 2.77E+00 4.49E+00 Cs-i 34 * - 3.41E+00 2.96E+00 Cs-137
  • 7.42E-01 2.57E+00 Ba-140
  • 6.16E+00 1.31 E+01 La-140 * - 1.74E+00 4.43E+00 Ra-226 * - 2.86E+01 2.57E+01 Th-228
  • 3.28E+00 1.91E+01
  • Denotes a result less than the detection limit.

TABLE A-7.1 (cont.)

GAMMA SPECTROMETRY OF WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY River/Drinking 29 07/02/02 - 08/06/02 Be-7

  • 9.17E-02 1.30E+01 K-40 *- 7.82E+00 1.87E+01 Mn-54 *- 8.70E-02 1.35E+00 Co-58
  • 2.97E-02 1.35E+00 Fe-59 * - 2.09E+00 2.88E+00 Co-60 * - 4.65E-01 1.34E+00 Zn-65 * - 4.45E-01 2.07E+00 Nb-95
  • 8.69E-01 1.25E+00 Zr-95 * - 3.04E-01 2.17E+00 Cs-134 * - 3.08E-02 8.98E-01 Cs-1 37
  • 4.28E-01 1.35E+00 Ba-140 * - 6.05E-01 7.84E+00 La-140 * - 8.13E-01 2.67E+00 Ra-226
  • 4.96E-01 2.06E+01 Th-228 * - 1.22E+00 2.43E+00 08/06/02 - 09/04/02 Be-7
  • 8.75E+00 2.64E+01 K-40 * - 2.16E+01 2.81 E+01 Mn-54
  • 7.97E-02 2.66E+00 Co-58 * - 9.45E-01 1.77E+00 Fe-59
  • 3.79E-01 2.44E+00 Zn-65
  • 3.59E-01 1.42E+00 Nb-95
  • 1.84E+00 2.57E+00 Zr-95
  • 2.71 E-01 4.53E+00 Cs-134
  • 1.01 E+01 2.84E+00 Cs-137 * - 7.60E-02 2.56E+00 Ba-140
  • 1.07E+01 2.07E+01 La-140
  • 5.57E-01 4.39E+00 09/03/02 - 10/01/02 Be-7 *- 5.04E+00 9.09E+00 K-40
  • 1.22E+01 1.51E+01 Mn-54 *- 2.22E-01 9.69E-01 Co-58 *- 4.94E-01 1.09E+00 Fe-59 *- 1.12E-01 2.25E+00 Co-60 *- 5.35E-01 9.44E-01 Zn-65 *- 3.42E+00 1.80E+00 Nb-95
  • 7.34E-01 9.79E-01 Zr-95
  • 1.58E+00 1.74E+00 Cs-134 *- 8.29E-01 8.30E-01 Cs-137
  • 2.69E-01 1.18E+00 Ba-140 *- 5.42E+00 8.90E+00 La-140
  • 2.22E+00 2.24E+00

' Denotes a result less than the detection limit.

TABLE A-7.1 (cont.)

GAMMA SPECTROMETRY OF WATER Results in pCilliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY River/Drinking 29 10/01/02 - 11/05/02 Be-7

  • 6.44E+00 1.71 E+01 K-40
  • 7.19E-02 1.63E+00 Co-58 * - 1.69E+00 1.62E+00 Fe-59 * - 1.46E+00 3.90E+00 Co-60 * - 4.43E-02 1.34E+00 Zn-65
  • 1.53E+00 3.70E+00 Nb-95 * - 7.76E-02 1.83E+00 Zr-95
  • 2.OOE+00 3.06E+00 Cs-1 34 * -4.OOE-01 1.72E+00 Cs-137 * - 1.92E+00 1.64E+00 Ba-140 * - 5.81E+00 1.24E+01 La-140 * - 1.65E+00 3.50E+00 Ra-226
  • 2.63E+01 5.79E+00 Th-228 * - 4.51E+00 5.35E+00 11/05/02 - 12/03/02 Be-7 * - 6.18E+00 1.63E+01 K-40
  • 1.75E+00 1.74E+00 Co-58
  • 3.34E-01 1.63E+00 Fe-59
  • 1.09E+00 3.42E+00 Co-60 * - 1.40E+00 1.86E+00 Zn-65 * - 2.29E+00 3.47E+00 Nb-95 * - 6.78E-01 1.86E+00 Zr-95
  • 1.92E+00 3.08E+00 Cs-134
  • 8.95E-01 1.81 E+00 Ba-140 * - 2.35E+00 9.57E+00 La-140
  • 1.94E+01 8.84E+01 Th-228 * - 3.12E+02 5.05E+01 12/03/02 - 01/02/03 Be-7 * - 5.01E+00 2.18E+01 K-40
  • 1.66E+00 2.32E+00 Co-58 * - 1.68E-02 2.25E+00 Fe-59
  • 2.92E+00 4.14E+00 Co-60 * - 2.51 E+00 2.47E+00 Zn-65 * - 1.03E+00 4.36E+00 Nb-95
  • 1.60E+00 2.37E+00 Zr-95
  • 2.57E+00 4.35E+00 Cs-134
  • 3.46E+00 2.61 E+00 Ba-140 * - 2.89E-01 1.07E+01 La-140 * - 2.96E-01 2.60E+00 Ra-226 * - 2.83E+01 1.58E+02 Th-228
  • 7.74E+01 6.67E+01
  • Denotes a result less than the detection limit.

TABLE A-7.1 (cont.)

GAMMA SPECTROMETRY OF WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY Discharge 27 01/02/02 - 02/05/02 Be-7

  • 1.39E+01 1.86E+01 K-40
  • 2.68E-02 1.75E+00 Co-58 * - 1.63E+00 2.07E+00 Fe-59
  • 5.93E-02 1.66E+00 Zn-65 * - 1.77E+00 2.16E+00 Nb-95
  • 6.70E-01 1.85E+00 Zr-95
  • 1.14E+00 3.30E+00 Cs-1 34 * - 2.77E-01 1.12E+00 Cs-137
  • 4.17E-01 1.69E+00 Ba-140
  • 2.20E+01 2.15E+01 La-140 * - 1.68E+00 6.99E+00 Ra-226 * - 4.21 E+00 2.35E+01 Th-228 * - 3.03E-01 1.62E+00 02/05/02 - 03/05/02 Be-7
  • 1.21 E+01 2.22E+01 K-40
  • 2.53E+01 2.24E+01 Mn-54 * - 1.44E+00 2.09E+00 Co-58
  • 6.30E-01 2.41 E+00 Fe-59
  • 3.68E-01 1.98E+00 Zn-65
  • 4.16E-01 2.13E+00 Nb-95
  • 8.36E-01 2.12E+00 Zr-95 * - 1.06E+00 3.90E+00 Cs-134
  • 1.03E+00 2.01 E+00 Ba-140 * - 1.07E+01 2.24E+01 La-140
  • 2.12E+00 1.51 E+01 03/05/02 - 04/02/02 Be-7
  • 3.71 E+00 1.54E+01 K-40 * - 4.78E+00 2.05E+01 Mn-54 * - 1.70E+00 1.81 E+00 Co-58
  • 1.20E+00 1.87E+00 Fe-59
  • 1.54E+00 3.59E+00 Co-60 * - 1.17E+00 1.77E+00 Zn-65 * - 2.72E+00 3.97E+00 Nb-95 * - 7.43E-01 1.50E+00 Zr-95 * - 3.29E-01 2.65E+00 Cs-1 34 * - 3.88E-01 1.07E+00 Cs-137
  • 1.56E+00 1.57E+00 Ba-140
  • 1.16E+00 8.20E+00 La-140
  • 3.65E-01 3.01 E+00 Ra-226 *- 8.90E-01 2.47E+01 Th-228 * - 1.64E+00 1.66E+00

^ Denotes a result less than the detection limit.

TABLE A-7.1 (cont.)

GAMMA SPECTROMETRY OF WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY Discharge 27 04/02/02 - 05/07/02 Be-7 *- 4.47E+00 2.34E+01 K-40

  • 1.82E+01 2.83E+01 Mn-54 *- 1.08E+00 2.34E+00 Co-58 *- 8.80E-01 2.35E+00 Fe-59 *- 1.66E-01 4.66E+00 Co-60
  • 3.01E-01 2.06E+00 Zn-65 *- 3.67E+00 5.54E+00 Nb-95 *- 1.58E-01 2.12E+00 Zr-95
  • 2.04E+00 3.86E+00 Cs-1 34 *- 8.87E-01 1.82E+00 Cs-i 37 *- 1.99E+00 2.42E+00 Ba-140
  • 1.16E+00 1.22E+01 La-140 *- 1.70E+00 3.93E+00 Ra-226
  • 3.36E+00 5.48E+00 05/07/02 - 06/04/02 Be-7
  • 3.21 E+00 1.74E+01 K-40
  • 9.70E-01 1.81 E+00 Co-58
  • 3.72E-01 1.94E+00 Fe-59
  • 1.27E+00 1.63E+00 Zn-65 * - 6.95E-01 2.84E+00 Nb-95
  • 2.10E+00 1.76E+00 Zr-95
  • 4.95E-01 3.05E+00 Cs-1 34 * - 3.90E-03 1.17E+00 Cs-I 37
  • 1.64E+00 1.72E+00 Ba-140 * - 3.32E-01 9.91 E+00 La-140 * - 4.83E-01 3.05E+00 Ra-226 * - 2.01E+01 4.48E+01 Th-228
  • 2.79E+00 1.85E+00 06/04/02 - 07/02/02 Be-7
  • 2.38E+00 1.59E+01 K-40
  • 7.41 E+00 1.76E+01 Mn-54 * - 9.12E-01 1.77E+00 Co-58
  • 1.11E-01 1.83E+00 Fe-59
  • 2.08E+00 1.61 E+00 Zn-65 * - 5.59E-01 9.30E-01 Nb-95
  • 3.85E-01 1.61 E+00 Zr-95
  • 1.24E+00 2.88E+00 Cs-134
  • 3.13E+00 1.67E+00 Ba-140 * - 1.79E+00 8.55E+00 La-140 * - 9.78E-01 2.80E+00 Ra-226 * - 1.11E+02 6.07E+01 Th-228
  • 8.25E+00 1.26E+01

' Denotes a result less than the detection limit.

TABLE A-7.1 (cont.)

GAMMA SPECTROMETRY OF WATER Results in pCifliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY Discharge 27 07/02/02 - 08/06/02 Be-7

  • 1.02E+01 1.27E+01 K-40 *- 1.73E+01 1.50E+01 Mn-54 * - 5.76E-01 1.31 E+00 Co-58 *- 7.62E-01 1.33E+00 Fe-59
  • 4.44E-01 1.20E+00 Zn-65 *- 1.39E+00 2.25E+00 Nb-95
  • 5.31 E-01 1.21 E+00 Zr-95
  • 1.07E-01 2.04E+00 Cs-1 34
  • 9.29E-01 7.67E-01 Cs-1 37 *- 5.51 E-01 1.32E+00 Ba-140
  • 9.03E+00 7.78E+00 La-140 * - 6.70E-02 2.54E+00 Ra-226
  • 1.41E+01 2.18E+01 Th-228 * - 2.73E+00 2.63E+00 08/06/02 - 09/04/02 Be-7
  • 4.53E+00 2.74E+01 K-40 *- 6.41E+01 3.45E+01 Mn-54 *- 1.60E-02 2.77E+00 Co-58 *- 1.33E-01 1.68E+00 Fe-59
  • 5.02E-01 2.73E+00 Zn-65 * - 7.08E+00 3.67E+00 Nb-95
  • 5.67E+00 2.70E+00 Zr-95 *- 8.80E-01 4.49E+00 Cs-1 34 *- 2.01E+01 3.35E+00 Cs-137
  • 1.45E+00 2.61 E+00 Ba-140 *- 8.80E-01 2.13E+01 La-1 40 2.86E+00 6.80E+00 Ra-226
  • 6.91 E+00 3.37E+01 Th-228 * - 7.95E-01 4.93E+00 09/03/02 - 10/01/02 Be-7
  • 3.82E+00 9.13E+00 K-40
  • 4.35E-02 8.77E-01 Co-58 * - 4.94E-01 9.64E-01 Fe-59
  • 2.03E+00 1.96E+00 Co-60 * - 7.69E-01 7.97E-01 Zn-65
  • 2.05E-02 1.01 E+00 Nb-95 *- 7.11E-01 8.69E-01 Zr-95
  • 8.44E-01 1.58E+00 Cs-1 34 *- 5.40E-01 5.73E-01 Cs-137
  • 8.19E-02 8.38E-01 Ba-140 7.41 E+00 8.23E+00 La-140 *- 5.16E-01 1.85E+00 Ra-226 * - 2.43E+00 1.39E+01 Th-228 * - 2.68E+00 1.93E+00

^ Denotes a result less than the detection limit.

TABLE A-7.1 (cont.)

GAMMA SPECTROMETRY OF WATER Results in pCilliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY Discharge 27 10/01/02 - 11/05/02 Be-7

  • 9.1 E+00 1.30E+01 K-40 *- 3.82E+01 2.55E+01 Mn-54
  • 3.68E-01 1.21 E+00 Co-58 * - 1.94E-01 1.23E+00 Fe-59
  • 1.80E-01 2.75E+00 Co-60 - 2.86E-01 1.09E+00 Zn-65 * - 1.37E+00 2.34E+00 Nb-95 * - 7.76E-01 1.39E+00 Zr-95 * - 2.02E-01 2.22E+00 Cs-I 34
  • 2.28E-01 1.21 E+00 Cs-137 * - 1.64E-01 1.28E+00 Ba-140
  • 1.71 E+00 1.25E+01 La-140 * - 1.94E+00 3.05E+00 Ra-226
  • 1.48E+01 5.67E+01 Th-228 * - 1.04E+02 3.09E+01 11/05/02 - 12/03/02 Be-7 * - 1.65E+00 1.81 E+01 K-40
  • 4.39E+00 6.04E+01 Mn-54 * - 2.OOE+00 2.12E+00 Co-58
  • 6.78E-01 2.11 E+00 Fe-59 * - 2.04E-01 4.30E+00 Co-60 * - 8.14E-01 2.71 E+00 Zn-65 * - 1.48E+01 4.88E+00 Nb-95 * - 8.71E-01 2.39E+00 Zr-95
  • 2.13E+00 3.85E+00 Cs-I 34 * - 7.44E+00 2.35E+00 Cs-1 37
  • 2.66E+00 3.OOE+00 Ba-140
  • 4.44E+00 1.10E+01 La-140 * - 1.56E+00 3.39E+00 Ra-226 * - 3.07E+01 6.OOE+01 Th-228 * - 3.67E+02 5.05E+01 12/03/02 - 01/02/03 Be-7
  • 1.65E+01 1.68E+01 K-40
  • 9.62E-01 1.91E+00 Co-58 * - 1.45E-01 1.85E+00 Fe-59
  • 1.22E+00 4.33E+00 Co-60 *- 1.40E+00 2.04E+00 Zn-65 * - 2.47E+00 4.37E+00 Nb-95 * - 1.64E-03 1.77E+00 Zr-95 * - 2.87E+00 3.12E+00 Cs-134
  • 1.28E+00 1.90E+00 Ba-140
  • 7.22E+00 7.63E+00 La-140
  • 9.69E+00 4.98E+01 Th-228 * - 1.07E+02 4.30E+01
  • Denotes a result less than the detection limit.

TABLE A-7.1 (cont.)

GAMMA SPECTROMETRY OF WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY Ground 31 03/05/02 Be-7 * - 2.68E+01 2.99E+01 K-40

  • 2.11E+00 3.16E+00 Co-58
  • 1.40E-01 3.53E+00 Fe-59
  • 3.76E+00 7.06E+00 Co-60 * - 1.32E+00 3.25E+00 Zn-65 * - 6.42E+00 6.38E+00 Nb-95 * - 4.26E+00 3.36E+00 Zr-95 * - 3.53E+00 5.76E+00 Cs-134
  • 1.02E+00 3.19E+00 Ba-140
  • 1.23E+01 1.53E+01 La-140 * - 3.35E+00 5.58E+00 Ra-226
  • 7.08E+01 7.58E+01 Th-228 * - 7.18E+00 7.38E+00 06/04102 Be-7
  • 2.29E+00 3.24E+01 K-40 * - 5.68E+00 5.10E+01 Mn-54
  • 2.83E+00 3.68E+00 Co-58 * - 1.14E+00 2.51 E+00 Fe-59
  • 2.91E-01 3.40E+00 Zn-65 * - 8.73E+00 4.34E+00 Nb-95
  • 3.97E+00 3.31 E+00 Zr-95 * - 3.72E+00 6.04E+00 Cs-134 * - 1.52E+00 4.07E+00 Cs-1 37
  • 6.56E+00 3.38E+00 Ba-140 * - 1.45E+01 2.04E+01 La-140
  • 6.98E+00 1.64E+01 09/04/02 Be-7 * - 1.06E+01 3.04E+01 K-40
  • 8.08E-01 2.57E+00 Co-58 * - 1.17E+00 2.07E+00 Fe-59
  • 1.27E+01 6.63E+00 Co-60 * - 2.16E+00 2.52E+00 Zn-65
  • 1.16E+00 3.57E+00 Nb-95
  • 2.22E+00 2.99E+00 Zr-95
  • 5.92E-01 5.25E+00 Cs-134
  • 1.15E-01 2.92E+00 Cs-137 * - 1.88E+00 3.05E+00 Ba-140 * - 1.47E+01 2.37E+01 La-140 * - 1.29E+00 7.26E+00 Ra-226
  • 3.53E+00 5.01 E+00

^ Denotes a result less than the detection limit.

TABLE A-7.1 (cont.)

GAMMA SPECTROMETRY OF WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY Ground 31 12103/02 Be-7

  • 1.72E+01 1.41E+01 K-40 * - 8.84E+01 4.44E+01 Mn-54
  • 7.99E-01 1.61 E+00 Co-58
  • 8.66E-01 1.64E+00 Fe-59 * - 1.59E+00 3.57E+00 Co-60
  • 1.57E+00 1.70E+00 Zn-65 * - 8.80E-02 3.95E+00 Nb-95 * - 8.68E-01 1.84E+00 Zr-95 * - 1.74E-01 2.85E+00 Cs-1 34 * - 9.57E-01 1.53E+00 Cs-137
  • 1.81E+00 1.77E+00 Ba-140
  • 9.93E+00 8.38E+00 La-140 * - 2.96E+00 2.84E+00 Ra-226
  • 4.93E+01 9.03E+01 Th-228 * - 2.13E+01 3.38E+01 32 03/05/02 Be-7
  • 5.03E+00 1.69E+01 K-40
  • 3.93E-02 1.86E+00 Co-58
  • 7.92E-01 1.94E+00 Fe-59
  • 1.09E+00 1.72E+00 Zn-65 * - 7.80E-02 1.01 E+00 Nb-95
  • 3.45E+00 1.74E+00 Zr-95 * - 3.46E-01 2.54E+00 Cs-I 34 * - 2.07E+00 2.22E+00 Cs-137
  • 3.44E+00 1.81E+00 Ba-140 * - 8.80E-01 9.52E+00 La-140
  • 4.92E-01 1.31 E+01 06104/02 Be-7
  • 1.35E+01 3.63E+01 K-40
  • 4.30E+00 3.99E+00 Co-58 * - 4.64E+00 4.26E+00 Fe-59
  • 8.04E-01 3.93E+00 Zn-65 * - 1.77E+01 5.79E+00 Nb-95
  • 6.39E-01 3.67E+00 Zr-95
  • 1.31 E+00 4.97E+00 Cs-1 34 * - 5.18E+00 4.69E+00 Cs-1 37
  • 4.45E+00 3.83E+00 Ba-140
  • 2.49E+00 2.18E+01 La-140
  • 5.14E+00 1.49E+01
  • Denotes a result less than the detection limit.

TABLE A-7.1 (cont.)

GAMMA SPECTROMETRY OF WATER Results in pCiliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY Ground 32 09/04/02 Be-7

  • 1.45E+00 2.55E+01 K-40
  • 6.15E-01 2.51E+00 Co-58 *- 1.13E+00 1.71E+00 Fe-59
  • 5.10E-01 2.41E+00 Zn-65
  • 6.34E-01 1.41 E+00 Nb-95
  • 3.OOE+00 2.50E+00 Zr-95 * - 1.19E+00 4.52E+00 Cs-134 * - 1.34E+00 2.39E+00 Cs-1 37
  • 2.52E-01 2.45E+00 Ba-140
  • 5.12E+00 1.97E+01 La-140
  • 3.97E+00 4.68E+00 12/03/02 Be-7
  • 2.34E+00 1.20E+01 K-40
  • 3.85E-01 1.69E+00 Co-58 * - 1.14E+00 1.55E+00 Fe-59 * - 1.22E+00 6.79E+00 Co-60
  • 1.11E+00 2.08E+00 Zn-65
  • 2.75E+00 6.83E+00 Nb-95 * - 1.81E+00 1.52E+00 Zr-95
  • 2.10E+00 2.57E+00 Cs-1 34
  • 7.32E-01 1.50E+00 Cs-1 37 * - 1.08E+00 2.12E+00 Ba-140
  • 9.24E+00 6.94E+00 La-140 * - 8.93E-01 1.93E+00 Ra-226
  • 6.19E+01 2.81E+01 52 03/05/02 Be-7
  • 3.76E-01 1.38E+01 K-40
  • 5.07E-01 1.53E+00 Co-58 * - 1.98E+00 1.57E+00 Fe-59
  • 1.01 E+00 1.40E+00 Zn-65
  • 1.00E+00 1.44E+00 Nb-95
  • 1.63E+00 1.36E+00 Zr-95 *- 2.28E+00 2.50E+00 Cs-134 * - 9.56E-01 1.75E+00 Cs-137
  • 9.71E-01 9.39E-01 Ba-140
  • 7.55E+00 7.66E+00 La-140
  • 3.64E-01 1.30E+00
  • Denotes a result less than the detection limit.

TABLE A-7.1 (cont.)

GAMMA SPECTROMETRY OF WATER Results inpCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY Ground 52 06/04/02 Be-7

  • 9.43E+00 3.72E+01 K-40
  • 2.13E+01 4.20E+01 Mn-54 * - 6.41E-01 3.65E+00 Co-58
  • 9.67E-01 4.13E+00 Fe-59
  • 1.29E+00 8.13E+00 Co-60 *- 1.88E+00 3.90E+00 Zn-65 * - 4.69E-01 5.06E+00 Nb-95 * - 1.74E+00 2.35E+00 Zr-95 * - 5.28E+00 6.51 E+00 Cs-i 34 * - 3.13E+01 5.04E+00 Cs-1 37
  • 1.50E+00 3.75E+00 Ba-140
  • 2.45E+01 2.34E+01 La-140 * - 1.31E+00 7.25E+00 Ra-226
  • 2.17E+01 2.33E+01 09/04/02 Be-7
  • 4.16E+00 9.21 E+00 K-40
  • 2.06E-01 8.89E-01 Co-58 * - 1.55E+00 1.02E+00 Fe-59
  • 3.54E+00 2.07E+00 Co-60 * - 3.66E-01 5.55E-01 Zn-65 * - 2.61E+00 1.24E+00 Nb-95
  • 9.07E-01 8.67E-01 Zr-95
  • 8.76E-02 1.34E+00 Cs-1 34
  • 1.93E-01 4.91E-01 Ba-140
  • 1.42E+00 7.73E+00 La-140
  • 1.63E+00 2.71 E+00 12/03/02 Be-7
  • 1.44E+01 2.98E+01 K-40 * - 8.05E+00 6.82E+01 Mn-54 * - 2.01 E+00 3.67E+00 Co-58 * - 7.21 E-01 3.72E+00 Fe-59
  • 4.58E-02 3.02E+00 Zn-65 * - 6.24E+00 7.99E+00 Nb-95
  • 4.29E-02 3.73E+00 Zr-95
  • 1.45E+00 5.93E+00 Cs-1 34 * - 3.19E+00 3.59E+00 Cs-137
  • 1.75E-01 3.69E+00 Ba-140
  • 2.11E+01 2.66E+01 La-140 * - 1.13E+00 6.16E+00 Ra-226 * - 7.17E+01 8.25E+01 Th-228
  • 7.80E+01 6.92E+01
  • Denotes a result less than the detection limit.

TABLE A-7.2 GAMMA SPECTROMETRY OF WATER -

SUMMARY

Results in pCi/liter NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE River/Drinkinq K-40 (I) 2.21 E+00 -6.20E+01 4.43E+01 12 0 K-40 (C) 3.68E+00 -3.09E+01 2.82E+01 12 Mn-54 (I) 6.04E-01 -5.97E-01 1.75E+00 12 Mn-54 (C) -5.80E-02 -1.34E+00 1.63E+00 12 Co-58 (I) -5.25E-01 -1.69E+00 1.21 E+00 12 Co-58 (C) -1.39E-01 -3.47E+00 1.68E+00 12 Fe-59 (I) 1.40E+00 -2.09E+00 4.78E+00 12 Fe-59 (C) 1.50E+00 -7.20E-01 4.95E+00 12 Co-60 (I) -3.44E-01 -2.51 E+00 1.44E+00 12 Co-60 (C) -3.01 E-01 -2.34E+00 1.08E+00 12 Zn-65 (I) -1.54E+00 -7.07E+00 1.53E+00 12 Zn-65 (C) -7.42E-01 -4.22E+00 4.67E+00 12 Nb-95 (I) 1.16E+00 -6.78E-01 2.63E+00 12 Nb-95 (C) 7.86E-01 -1.44E+00 3.92E+00 12 Zr-95 (I) 9.97E-01 -2.77E+00 3.50E+00 12 Zr-95 (C) 4.43E-01 -2.92E+00 3.08E+00 12 0 (I) Indicator Stations (C) Control Stations

TABLE A-7.2 GAMMA SPECTROMETRY OF WATER -

SUMMARY

Results inpCUliter NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE RiverJDrinking Cs-1 34 (I) 9.78E-01 -3.57E+00 1.01 E+01 12 0 Cs-1 34 (C) -3.26E+00 -1.73E+01 5.20E+00 12 0 Cs-137 (I) 4.51 E-01 -1.92E+00 3.46E+00 12 0 Cs-1 37 (C) 5.61 E-01 -1.07E+00 2.88E+00 12 0 Ba-140 (I) 3.36E-01 -8.88E+00 1.21 E+01 12 0 Ba-140 (C) 3.61 E-01 -7.54E+00 1.20E+01 12 0 La-140 (I) 6.82E-01 -1.74E+00 5.75E+00 12 0 La-1 40 (C) 7.93E-01 -1.95E+00 3.24E+00 12 0 Ra-226 (I) -3.47E+00 -7.75E+01 3.67E+01 12 0 Ra-226 (C) 1.24E+01 -1.98E+01 8.72E+01 12 0 Th-228 (I) -1.88E+01 -3.12E+02 7.74E+01 12 0 Th-228 (C) -2.48E+00 -2.44E+01 2.26E+01 12 0 (I) Indicator Stations (C) Control Stations

TABLE A-7.2 (cont.)

GAMMA SPECTROMETRY OF WATER -

SUMMARY

Results in pCi/liter NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE Discharge K-40 (I) -1.14E-01 -6.41 E+01 4.74E+01 12 0 Mn-54 (I) -4.46E-01 -2.OOE+00 9.70E-01 12 Co-58 (I) -1.04E-01 -1.63E+00 1.20E+00 12 Fe-59 (I) 1.37E+00 -2.04E-01 3.78E+00 12 Co-60 (I) 4.88E-02 -1.40E+00 2.08E+00 12 Zn-65 (I) -3.01 E+00 -1.48E+01 4.16E-01 12 Nb-95 (I) 5.78E-01 -8.71 E-01 5.67E+00 12 Zr-95 (I) 2.21 E-01 -2.87E+00 2.13E+00 12 Cs-1 34 (I) -1.94E+00 -2.01 E+01 2.34E+00 12 Cs-137 (I) 8.79E-01 -1.99E+00 3.13E+00 12 Ba-140 (I) 3.37E+00 -1.07E+01 2.20E+01 12 La-140 (I) -2.62E-01 -1.94E+00 2.86E+00 12 Ra-226 (I) -6.59E+00 -1.11 E+02 6.24E+01 12 Th-228 (I) -4.75E+01 -3.67E+02 8.25E+00 12 (I) Indicator Stations

TABLE A-7.2 (cont.)

GAMMA SPECTROMETRY OF WATER -

SUMMARY

Results in pCi/liter NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE Ground K-40 (I) 1.64E+01 -8.84E+01 1.42E+02 12 0 Mn-54 (I) 8.29E-01 -2.01E+00 4.30E+00 12 0 Co-58 (I) -8.92E-01 -4.64E+00 9.67E-01 12 0 Fe-59 (I) 2.54E+00 -1.59E+00 1.27E+01 12 0 Co-60 (I) 5.87E-02 -2.16E+00 1.57E+00 12 0 Zn-65 (I) -3.07E+00 -1.77E+01 2.75E+00 12 0 Nb-95 (I) 5.98E-01 -4.26E+00 3.97E+00 12 0 Zr-95 (I) -9.15E-01 -5.28E+00 2.1OE+00 12 0 Cs-134 (I) -3.66E+00 -3.13E+01 1.18E+00 12 0 Cs-137 (I) 1.45E+00 -1.88E+00 6.56E+00 12 0 Ba-140 (I) 5.30E+00 -1.47E+01 2.45E+01 12 0 La-140 (I) 7.90E-01 -3.35E+00 8.75E+00 12 0 Ra-226 (I) 2.46E+01 -7.17E+01 8.30E+01 12 0 Th-228 (I) 1.29E+01 -2.13E+01 7.80E+01 12 0 (I) Indicator Stations

TABLE A-8.1 GAMMA SPECTROMETRY OF SOIL Results in pCilkilogram COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 01 05/16/02 K-40 1.76E+04 6.50E+02 Cs-1 34

  • 9.49E-01 7.03E+00 Cs-137 4.22E+02 1.84E+01 Ra-226 1.20E+03 1.44E+02 Th-228 7.11E+02 2.05E+01 07 05/16/02 K-40 1.60E+04 6.OOE+02 Cs-134 * - 3.99E+00 7.91 E+00 Cs-137 4.13E+01 8.48E+00 Ra-226 1.12E+03 1.70E+02 Th-228 6.96E+02 2.16E+01 9A 05/16/02 K-40 1.60E+04 8.50E+02 Cs-1 34
  • 1.61E+01 2.48E+01 Ra-226 1.45E+03 2.97E+02 Th-228 7.52E+02 3.48E+01 21 05/16/02 K-40 5.57E+03 2.33E+02 Cs-134 * - 5.84E+00 8.45E+00 Cs-137
  • 1.13E+00 6.06E+00 Ra-226 3.05E+02 5.54E+01 Th-228 1.40E+02 3.16E+01 23 05/16/02 K-40 1.62E+04 7.80E+02 Cs-1 34 - 3.30E+00 8.79E+00 Cs-137 1.09E+02 1.72E+01 Ra-226
  • 8.26E+02 2.83E+02 Th-228 4.48E+02 1.18E+02

^ Denotes a result less than the detection limit.

TABLE A-8.2 GAMMA SPECTROMETRY OF SOIL -

SUMMARY

Results in pCi/kilogram NUMBER NUMBER NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE K-40 (I) 1.38E+04 5.57E+03 1.76E+04 4 4 K-40 (C) 1.60E+04 1.60E+04 1.60E+04 1 1 Cs-1 34 (I) -3.05E+00 -5.84E+00 9.49E-01 4 0 Cs-134 (C) 4.23E-01 4.23E-01 4.23E-01 1 0 Cs-1 37 (I) 1.43E+02 1.13Ei00 4.22E+02 4 3 Cs-137 (C) 1.61E+01 1.61 E+01 1.61 E+01 I 0 Ra-226 (I) 8.63E+02 3.05E+02 1.20E+03 4 3 Ra-226 (C) 1.45E+03 1.45E+03 1.45E+03 I 1 Th-228 (I) 4.99E+02 1.40E+02 7.11E+02 4 4 Th-228 (C) 7.52E+02 7.52E+02 7.52E+02 1 I (I) Indicator Stations (C) Control Stations

TABLE A-9.1 GAMMA SPECTROMETRY OF SEDIMENT Results in pCikilogram COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 33 03/20/02 K-40 1.32E+04 4.30E+02 (upstream) Co-57

  • 1.93E+00 8.14E+00 Cs-134
  • 1.28E+00 5.61 E+00 Cs-1 37 4.03E+01 6.74E+00 Eu-1 52
  • 4.32E+01 2.51 E+01 Ra-226 5.40E+02 1.54E+01 Ac-228 9.63E+02 3.50E+01 Th-228 8.02E+02 3.40E+01 U-235 2.37E+01 7.96E+00 10/29/02 K-40
  • 7.54E+00 1.59E+01 Cs-134
  • 6.04E+00 1.73E+01 Cs-137 5.54E+01 2.92E+01 Eu-152 * - 3.59E+01 5.38E+01 Ra-226 8.11E+02 4.74E+01 Ac-228
  • 1.02E+03 1.06E+02 Th-228 2.40E+03 5.83E+02 U-235 * - 1.43E+01 9.77E+01 34 03/20/02 K-40 2.12E+04 7.90E+02 (Downstream) Co-57
  • 9.24E+00 1.49E+01 Cs-1 34 * - 9.59E+00 9.11 E+00 Cs-137 2.26E+02 1.51 E+01 Eu-152 5.68E+01 1.88E+01 Ra-226 5.79E+02 2.21 E+01 Ac-228 1.01 E+03 5.OOE+01 Th-228 8.29E+02 4.68E+01 U-235 5.82E+01 1.11E+01 10/29/02 K-40 2.14E+04 8.88E+02 Co-57
  • 1.53E+00 1.61 E+01 Cs-134 * - 3.11E-01 1.41E+01 Cs-1 37 2.88E+02 4.50E+01 Eu-1 52
  • 9.30E+01 6.32E+01 Ra-226 9.15E+02 5.51 E+01 Ac-228 1.38E+03 2.41 E+02 Th-228 3.64E+03 8.51 E+02 U-235
  • 5.75E+01 9.05E+01

^ Denotes a result less than the detection limit.

TABLE A-9.2 GAMMA SPECTROMETRY OF SEDIMENT -

SUMMARY

Result InpCiVkilogram NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE K-40 (I) 2.13E+04 2.12E+04 2.14E+04 2 2 K-40 (C) 1.59E+04 1.32E+04 1.86E+04 2 1 Co-57 (I) 1.45E+01 8.27E+00 2.07E+01 2 0 Co-57 (C) 4.49E+00 3.70E+00 5.27E+00 2 0 Co-60 (I) 5.39E+00 1.53E+00 9.24E+00 2 0 Co-60 (C) 4.74E+00 1.93E+00 7.54E+00 2 0 Cs-134 (I) -4.95E+00 -9.59E+00 -3.11E-01 2 0 Cs-134 (C) 3.66E+00 1.28E+00 6.04E+00 2 0 Cs-1 37 (I) 2.57E+02 2.26E+02 2.88E+02 2 2 Cs-1 37 (C) 4.79E+01 4.03E+01 5.54E+01 2 2 Eu-152 (I) 7.49E+01 5.68E+01 9.30E+01 2 1 Eu-1 52 (C) 3.65E+00 -3.59E+01 4.32E+01 2 0 Ra-226 (I) 7.47E+02 5.79E+02 9.15E+02 2 2 Ra-226 (C) 6.76E+02 5.40E+02 8.11E+02 2 2 Ac-228 (I) 1.20E+03 1.01 E+03 1.38E+03 2 2 Ac-228 (C) 9.92E+02 9.63E+02 1.02E+03 2 1 (I) Indicator Stations (C) Control Stations

TABLE A-9.2 GAMMA SPECTROMETRY OF SEDIMENT -

SUMMARY

Result in pCikilogram NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE Th-228 (I) 2.23E+03 8.29E+02 3.64E+03 2 2 Th-228 (C) 1.60E+03 8.02E+02 2.40E+03 2 2 U-235 (I) 5.79E+01 5.75E+01 5.82E+01 2 I U-235 (C) 4.72E+oo -1.43E+01 2.37E+01 2 I (1) Indicator Stations (C) Control Stations

TABLE A-10.1 GAMMA SPECTROMETRY OF FISH Results inpCUkilogram (wet)

COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 38 11/21/02 K-40 1.44E+03 2.39E+02 Carp Mn-54 *- 5.81E+00 8.09E+00 Co-58

  • 3.96E-01 9.65E+00 Fe-59 *- 1.41 E+01 2.41 E+01 Co-60 *- 1.74E+00 7.75E+00 Zn-65 *- 6.86E+01 2.02E+01 Cs-1 34 *- 4.25E+01 8.40E+00 Cs-1 37 *- 2.85E+00 1.10E+01 Ra-226 *- 2.59E+01 2.26E+02 Th-228
  • 2.26E+01 1.97E+02 38 11/11/02 K-40 3.59E+03 2.26E+02 Sucker Mn-54 *- 4.30E+00 6.84E+00 Co-58 *- 1.68E+01 8.99E+00 Fe-59 *- 1.41 E+01 2.37E+01 Co-60 *- 6.77E-02 6.51E+00 Zn-65 *- 2.02E+00 1.75E+01 Cs-134
  • 7.45E-01 7.65E+00 Cs-1 37
  • 4.60E+02 1.57E+02 38 11/19/02 K-40 3.90E+03 2.94E+02 Salmon Mn-54 * - 2.01 E+00 1.08E+01 Co-58
  • 1.47E+00 1.04E+01 Fe-59 * - 1.62E+01 2.72E+01 Co-60
  • 1.52E+00 8.23E+00 Zn-65 * - 6.44E+01 2.12E+01 Cs-1 34 * - 2.54E+01 8.58E+00 Cs-137
  • 2.85E+01 2.34E+02 Th-228 * - 9.60E+02 2.17E+02
  • Denotes a result less than the detection limit.
  • Denotes a result less than the detection limit.

TABLE 10-A.1 (Cont)

GAMMA SPECTROMETRY OF FISH Results in pCilkilogram (wet)

COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 39 11/13/02 K-40 3.81E+03 2.52E+02 Carp Mn-54 * - 2.44E+00 7.78E+00 Co-58 * - 8.21 E+00 9.80E+00 Fe-59

  • 5.96E+00 7.75E+00 Zn-65 * - 6.21E+01 2.13E+01 Cs-134 * - 1.59E+01 7.76E+00 Cs-137
  • 1.18E+01 7.97E+00 Ra-226 * - 1.57E+02 2.05E+02 Th-228 * - 1.77E+02 1.75E+02 39 11/21/02 K-40 4.24E+03 2.46E+02 Sucker Mn-54
  • 1.01 E+01 8.48E+00 Co-58 * - 3.66E+00 1.06E+01 Fe-59
  • 1.85E+00 2.49E+01 Co-60 * - 4.29E+00 1.23E+01 Zn-65 * - 5.91 E+00 1.97E+01 Cs-1 34
  • 4.85E+01 9.26E+00 Cs-1 37 * - 3.24E+00 1.10E+01 Ra-226
  • 5.71 E+02 1.94E+02 39 11/07/02 K-40 3.68E+03 2.48E+02 Salmon Mn-54 * - 5.94E-02 5.57E+00 Co-58 * - 2.51 E+00 7.47E+00 Fe-59
  • 1.82E+00 4.97E+00 Zn-65 * - 1.04E+01 1.23E+01 Cs-1 34 * - 2.41 E+00 5.18E+00 Cs-137
  • 1.70E+02 2.67E+02 Th-228 * - 4.32E+02 1.61 E+02

' Denotes a result less than the detection limit.

Denotes a result less than the detection limit.

TABLE A-10.2 GAMMA SPECTROMETRY OF FISH -

SUMMARY

Results in pCi/kilogram NUMBER NUMBER NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE K-40 (I) 3.91 E+03 3.68E+03 4.24E+03 3 3 K-40 (C) 2.98E+03 1.44E+03 3.90E+03 3 3 Co-60 (I) 1.16E+00 -4.29E+00 5.96E+00 3 0 Co-60 (C) -9.59E-02 -1.74E+00 1.52E+00 3 0 Fe-59 (I) 5.55E+00 1.85E+00 1.02E+01 3 0 Fe-59 (C) -1.48E+01 -1.62E+01 -1.41 E+01 3 0 Zn-65 (I) -2.61 E+01 -6.21E+01 -5.91 E+00 3 0 Zn-65 (C) -4.50E+01 -6.86E+01 -2.02E+00 3 0 Co-58 (I) -4.79E+00 -8.21 E+00 -2.51 E+00 3 0 Co-58 (C) -4.98E+00 -1.68E+01 1.47E+00 3 0 Cs-1 34 (I) 1.01 E+01 -1.59E+01 4.85E+01 3 0 Cs-134 (C) -2.24E+01 -4.25E+01 7.45E-01 3 0 Cs-1 37 (I) 5.42E+00 -3.24E+00 1.18E+01 3 0 Cs-1 37 (C) 1.16E+00 -2.85E+00 3.70E+00 3 0 Mn-54 (I) 2.53E+00 -2.44E+00 1.01 E+01 3 0 Mn-54 (C) -4.04E+00 -5.81 E+00 -2.01 E+00 3 0 (I) Indicator Stations (C) Control Stations

TABLE A-10.2 GAMMA SPECTROMETRY OF FISH -

SUMMARY

Results in pCi/kilogram (wet)

NUMBER NUMBER NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE -

Ra-226 (I) 1.39E+02 -1.57E+02 4.05E+02 3 0 Ra-226 (C) -5.15E+01 -1.57E+02 2.85E+01 3 0 Th-228 (I) -1.27E+01 -4.32E+02 5.71 E+02 3 0 Th-228 (C) -1.59E+02 -9.60E+02 4.60E+02 3 0 (I) Indicator Stations (C) Control Stations

TABLE A-11.1 1-131 IN MILK Results inpCi/liter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 9B 01/15/02

  • 9.90E-02 1.51E-01 02/12/02 * - 2.10E-01 2.54E-01 03/12102 * - 3.10E-02 2.02E-01 04/09/02
  • 1.70E-01 1.89E-01 04/23/02
  • 8.50E-02 2.77E-01 05/07/02 * - 5.61E-02 1.75E-01 05/21/02
  • 3.27E-01 2.67E-01 06/11/02
  • 5.18E-02 3.17E-01 06/25/02 * - 5.09E-01 4.46E-01 07/09/02
  • 1.66E-01 2.42E-01 07/23/02
  • 5.93E-01 6.08E-01 08/13102 * - 1.34E+00 2.50E-01 08/27/02
  • 1.29E-01 2.78E-01 09/10/02 * - 6.94E-01 3.40E-01 09/24/02
  • 1.22E-01 2.42E-01 10/15/02 * - 1.62E-01 2.99E-01 11/12/02
  • 8.78E-02 3.30E-01 12/10/02 * - 2.86E-01 5.04E-01 36 01115/02
  • 7.80E-02 1.31E-01 02/12/02
  • 4.20E-02 2.87E-01 03112/02 * - 2.40E-02 1.52E-01 04/09/02
  • 3.60E-02 2.46E-01 04123/02
  • 3.30E-01 2.61E-01 05/07/02
  • 5.41 E-02 1.78E-01 05/21/02 * - 6.28E-01 3.70E-01 06/11/02 * - 1.22E-01 4.01 E-01 06/25/02
  • 2.20E-01 4.35E-01 07/09/02 * - 2.41E-02 2.38E-01 07/23/02 * - 3.79E-01 4.62E-01 08/13/02
  • 5.45E-02 2.22E-01 08/27/02 *- 1.99E-01 3.49E-01 09110/02
  • 3.33E-01 2.45E-01 09/24/02
  • 1.40E-01 2.17E-01 10/15/02
  • 2.50E-01 3.22E-01 11/12/02 (1) 12/10/02
  • 3.74E-01 3.75E-01 Denotes a result less than the detection limit.

(1) Result not reported due to the presence of a non-decaying beta emitter.

TABLE A-11.1 (cont.)

1-131 IN MILK Results inpCi/liter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 64 01/15/02

  • 1.10E-01 1.54E-01 02/12/02
  • 5.70E-02 1.79E-01 03/12/02
  • 1.20E-01 1.87E-01 04/09/02
  • 6.10E-02 1.41E-01 04/23/02
  • 7.30E-02 1.63E-01 05/07/02
  • 2.98E-02 1.87E-01 05/21102
  • 2.73E-01 1.86E-01 06/11/02
  • 1.12E-01 3.50E-01 06/25/02 * - 9.44E-02 4.93E-01 07/09/02
  • 1.27E-01 2.14E-01 07/23/02 * - 2.02E-02 4.50E-01 08/13/02
  • 1.76E-01 1.61E-01 08/27/02
  • 1.80E-01 2.78E-01 09/10/02 *- 1.43E-02 1.90E-01 09/24/02
  • 3.88E-01 2.53E-01 10/15/02
  • 3.OOE-01 2.09E-01 11/12/02
  • 2.60E-01 2.89E-01 12/10/02
  • 7.21E-01 4.68E-01

' Denotes a result less than the detection limit.

TABLE A-1 1.2 1-131 IN MILK -

SUMMARY

Results in pCi/liter NUMBER NUMBER NUMBER NUMBER NUCLIDE AVERAI GE LOW HIGH SAMPLES POSITIVE 1-131 (I) 3.65E-( )2 -1.34E+00 7.21 E-01 53 0 (I) Indicator Stations

TABLE A-12.1 GAMMA SPECTROMETRY OF MILK Results inpCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 9B 01/16/01 K-40 1.27E+03 7.OOE+01 Cs-1 34 * - 9.68E-01 4.22E+00 Cs-137 * - 1.16E-01 1.24E+00 Ba-140

  • 1.27E+01 1.76E+01 La-140
  • 4.67E+00 5.25E+00 02/13/01 K-40 1.48E+03 8.80E+01 Cs-1 34 * - 4.62E-01 1.81 E+00 Cs-1 37
  • 3.57E-01 3.11 E+00 Ba-140
  • 9.11E+00 1.56E+01 La-1 40 * - 3.14E+00 4.95E+00 03/13/01 K-40 1.11E+03 4.80E+01 Cs-134
  • 1.80E-01 1.11E+00 Ba-140 * - 3.41 E+00 5.05E+00 La-140 * - 3.46E-01 1.44E+00 04/09/02 K-40 1.51E+03 8.60E+01 Cs-134
  • 1.39E+01 4.24E+00 Cs-1 37
  • 6.23E-01 3.91E+00 Ba-140
  • 1.19E+01 2.04E+01 La-140 * - 1.99E+00 6.48E+00 04/23/02 K-40 1.54E+03 7.90E+01 Cs-1 34
  • 7.13E+00 3.20E+00 Cs-1 37
  • 2.25E-01 3.13E+00 Ba-140 * - 5.96E+00 1.29E+01 La-140
  • 4.13E+00 4.31E+00 05/07/02 K-40 1.51E+03 8.60E+01 Cs-134
  • 1.23E+01 3.81E+00 Cs-1 37
  • 2.62E+00 3.55E+00 Ba-140
  • 5.80E+00 1.85E+01 La-140
  • 1.20E+00 5.78E+00 05/21/02 K-40 1.39E+03 8.20E+01 Cs-1 34 * -1.21 E+00 4.70E+00 Cs-137
  • 2.21E+00 4.08E+00 Ba-140 * -6.15E+00 2.10E+01 La-140 * -2.04E+00 3.28E+00
  • Denotes a result less than the detection limit.

TABLE A-12.1 (Cont.)

GAMMA SPECTROMETRY OF MILK Results in pCilliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 9B 06/11/02 K-40 1.48E+03 8.80E+01 Cs-134

  • 9.85E+00 4.71 E+00 Cs-I 37 * - 4.15E-01 4.14E+00 Ba-140 * - 1.24E+01 2.27E+01 La-140
  • 6.28E-01 7.OOE+00 06/25/02 K-40 1.21 E+03 4.80E+01 Cs-1 34
  • 8.30E-01 5.30E-01 Cs-1 37
  • 6.30E-01 8.72E-01 Ba-140 * - 5.15E-01 3.73E+00 La-140
  • 5.21E-01 1.19E+00 07/09/02 K-40 1.41 E+03 1.07E+02 Cs-I 34
  • 1.94E-01 4.23E+00 Ba-140
  • 8.42E-02 8.10E+00 La-140
  • 2.34E+00 6.89E+00 07/23/02 K-40 1.54E+03 9.10E+01 Cs-1 34 *- 6.22E-01 1.74E+00 Cs-1 37 *- 8.37E-01 2.90E+00 Ba-140 *- 5.23E+00 1.60E+01 La-140
  • 1.35E+00 5.18E+00 08/13/02 K-40 1.38E+03 9.10E+01 Cs-1 34 * - 2.08E+00 2.19E+00 Cs-137
  • 1.22E+00 1.80E+00 Ba-140 * - 4.10E-01 1.51 E+01 La-1 40 * - 6.39E-01 5.24E+00 08/27/02 K-40 1.36E+03 8.50E+01 Cs-134
  • 2.40E+00 2.75E+00 Ba-140
  • 2.20E-02 1.54E+01 La-140 *- 3.55E+00 5.37E+00 09/10/02 K-40 1.54E+03 8.20E+01 Cs-134 * - 6.71E-01 1.87E+00 Cs-137
  • 1.48E+00 *2.46E+00 Ba-140
  • 1.05E+00 1.34E+01 La-140 * - 2.39E+00 4.54E+00

' Denotes a result less than the detection limit.

TABLE A-12.1 (Cont.)

GAMMA SPECTROMETRY OF MILK Results inpCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 9B 09/24/02 K-40 1.32E+03 8.20E+01 Cs-134

  • 6.32E-01 1.83E+00 Cs-1 37
  • 9.95E-01 2.73E+00 Ba-140
  • 1.27E+01 1.36E+01 La-140
  • 6.48E+00 4.18E+00 10/15/02 K-40 1.59E+03 6.20E+01 Cs-I 34 * - 1.29E+00 8.93E-01 Cs-137 * - 2.16E-01 1.34E+00 Ba-140
  • 5.91 E+00 1.47E+01 La-140 * - 1.44E+00 3.94E+00 11/12/02 K-40 1.45E+03 9.52E+01 Cs-1 34 * - 5.03E-01 1.83E+00 Cs-137
  • 2.58E+00 1.88E+00 Ba-140 * - 6.36E+00 9.97E+00 La-140 * - 9.32E-01 2.70E+00 12110/02 K-40 1.54E+03 9.88E+01 Cs-1 34 * - 9.78E-02 1.62E+00 Cs-137
  • 1.24E+00 1.89E+00 Ba-140
  • 2.50E-01 8.61 E+00 La-1 40 * - 7.87E-02 2.90E+00
  • Denotes a result less than the detection limit.

TABLE A-12.1 (Cont.)

GAMMA SPECTROMETRY OF MILK Results inpCiliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 36 01/16/01 K-40 1.38E+03 7.80E+01 Cs-134

  • 5.30E-01 4.13E+00 Cs-1 37
  • 2.53E+00 3.69E+00 Ba-140
  • 4.39E+00 1.82E+01 La-140
  • 9.40E-01 5.80E+00 02/13/01 K-40 1.43E+03 8.20E+01 Cs-134 * - 1.12E+00 1.86E+00 Cs-1 37 * - 3.30E-02 2.60E+00 Ba-140
  • 5.83E+00 1.34E+01 La-140 * - 6.70E-02 4.41E+00 03/13/01 K-40 1.23E+03 4.90E+01 Cs-134 * - 1.19E-01 5.65E-01 Cs-1 37 * - 8.69E-01 1.OOE+00 Ba-140 * - 6.77E+00 4.89E+00 La-140 * - 4.90E-02 1.22E+00 04/09/02 K-40 1.51 E+03 8.90E+01 Cs-134
  • 1.43E+00 4.07E+00 Ba-140
  • 1.44E+01 2.25E+01 La-140
  • 1.34E+00 6.86E+00 04/23/02 K-40 1.52E+03 6.90E+01 Cs-134
  • 1.12E+01 2.99E+00 Cs-137 * - 1.54E-01 1.52E+00 Ba-140
  • 4.29E+00 1.14E+01 La-140
  • 2.37E+00 3.50E+00 05/07102 K-40 1.51 E+03 8.90E+01 Cs-1 34
  • 1.09E+01 4.73E+00 Cs-1 37
  • 2.63E+00 4.17E+00 Ba-140
  • 1.37E+01 2.20E+01 La-140
  • 2.11E+00 6.66E+00 05/21/02 K-40 1.59E+03 7.90E+01 Cs-I 34
  • 1.26E+00 1.64E+00 Ba-140
  • 1.19E+01 1.71E+01 La-140
  • 4.03E+00 5.02E+00
  • Denotes a result less than the detection limit.

TABLE A-12.1 (Cont.)

GAMMA SPECTROMETRY OF MILK Results in pCiliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 36 06/11/02 K-40 1.58E+03 8.30E+01 Cs-1 34 * - 3.74E+00 3.33E+00 Cs-137

  • 1.19E+00 1.98E+00 Ba-140
  • 3.15E+00 1.74E+01 La-140 * - 1.67E+00 5.50E+00 06/25/02 K-40 1.51 E+03 5.70E+01 Cs-i 34 *- 2.20E-01 7.33E-01 Cs-137
  • 1.37E+00 9.20E-01 Ba-140 *- 5.63E-01 4.62E+00 La-140
  • 9.11E-01 1.41 E+00 07/09/02 K-40 1.51E+03 1.01 E+02 Cs-134 * - 1.89E+00 4.65E+00 Cs-1 37
  • 9.58E-02 3.63E+00 Ba-140
  • 3.89E+00 1.95E+01 La-140 * - 4.81 E+00 6.42E+00 07/23/02 K-40 1.60E+03 9.20E+01 Cs-1 34
  • 1.54E+00 2.36E+00 Cs-I 37
  • 2.65E-01 2.88E+00 Ba-140
  • 5.02E+00 1.45E+01 La-140 *- 4.61 E+00 4.92E+00 08/13/02 K-40 1.40E+03 7.90E+01 Cs-134
  • 7.64E-01 1.58E+00 Ba-140
  • 1.85E+00 1.20E+01 La-140
  • 5.51E+00 3.97E+00 08127/02 K-40 1.44E+03 8.1OE+01 Cs-134 * - 2.19E+01 4.81E+00 Cs-1 37
  • 2.84E+00 3.76E+00 Ba-140 * - 1.53E+01 2.37E+01 La-140 * - 1.44E+00 7.23E+00 09110102 K-40 1.45E+03 9.50E+01 Cs-134
  • 1.68E+01 4.76E+00 Cs-1 37 *- 1.65E+00 4.41E+00 Ba-140 *- 1.33E+01 2.28E+01 La-140 *- 3.92E-01 2.30E+00

' Denotes a result less than the detection limit.

TABLE A-12.1 (Cont.)

GAMMA SPECTROMETRY OF MILK Results in pCiliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 36 09/24/02 K-40 1.31 E+03 8.30E+01 Cs-134

  • 1.41 E+00 2.65E+00 Ba-140
  • 7.43E+00 1.28E+01 La-140
  • 1.61 E+00 3.84E+00 10/15/02 K-40 1.54E+03 7.40E+01 Cs-134 * - 1.59E+00 1.45E+00 Cs-137
  • 1.28E+00 2.09E+00 Ba-140
  • 1.19E+01 2.32E+01 La-140
  • 2.44E-01 7.04E+00 11/12/02 K-40 1.57E+03 8.30E+01 Cs-134
  • 2.95E-01 1.95E+00 Cs-1 37
  • 2.55E-01 2.43E+00 Ba-140
  • 5.18E+00 1.37E+01 La-140 *- 2.02E+00 4.52E+00 12/10/02 K-40 1.63E+03 8.25E+01 Cs-1 34 * - 6.76E+00 2.05E+00 Cs-137
  • 7.17E-01 2.06E+00 Ba-140 * - 5.11E+00 9.10E+00 La-140 * - 1.99E-01 2.60E+00
  • Denotes a result less than the detection limit.

TABLE A-12.1 (Cont.)

GAMMA SPECTROMETRY OF MILK Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 64 01/16/01 K-40 1.40E+03 8.OOE+01 Cs-1 34 * - 1.65E+00 4.59E+00 Cs-1 37

  • 7.28E+00 3.80E+00 Ba-140
  • 4.79E+00 1.91E+01 La-140 * - 9.09E-01 5.79E+00 02/13/01 K-40 1.56E+03 1.14E+02 Cs-134
  • 1.62E+00 3.84E+00 Ba-140
  • 2.55E+00 1.93E+01 La-140 * - 8.88E+00 7.13E+00 03/13/01 K-40 1.62E+03 6.OOE+01 Cs-1 34
  • 1.64E-01 7.86E-01 Cs-1 37 * - 1.02E+00 1.10E+00 Ba-140
  • 4.05E+00 4.57E+00 La-140
  • 1.03E+00 1.29E+00 04/09/02 K-40 1.56E+03 9.20E+01 Cs-134
  • 1.84E+00 4.73E+00 Cs-1 37 * - 6.13E-01 4.20E+00 Ba-140 * - 1.88E+00 2.27E+01 La-140 * - 7.66E-01 7.08E+00 04/23/02 K-40 1.52E+03 7.80E+01 Cs-134
  • 1.37E+01 3.73E+00 Cs-I 37
  • 3.29E+00 3.36E+00 Ba-140
  • 6.31E-01 1.48E+01 La-140 * - 1.78E-01 4.59E+00 05/07/02 K-40 1.46E+03 8.50E+01 Cs-134
  • 1.16E+01 4.47E+00 Cs-1 37 * - 2.53E+00 3.15E+00 Ba-140
  • 9.38E+00 2.04E+01 La-140 * - 8.30E-01 6.42E+00 05/21/02 K-40 1.46E+03 8.30E+01 Cs-1 34 * - 5.22E+00 4.59E+00 Cs-1 37
  • 6.28E+00 4.02E+00 Ba-140
  • 9.87E+00 2.18E+01 La-140 2.78E+00 6.57E+00
  • Denotes a result less than the detection limit.

TABLE A-12.1 (Cont.)

GAMMA SPECTROMETRY OF MILK Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 64 06/11/02 K-40 1.89E+03 8.30E+01 Cs-134

  • 2.12E+01 3.80E+00 Cs-I 37
  • 5.90E+00 3.38E+00 Ba-140
  • 3.07E+00 1.83E+01 La-140
  • 3.29E+00 5.82E+00 06/25/02 K-40 1.52E+03 5.80E+01 Cs-1 34 * - 3.40E-01 9.17E-01 Cs-137
  • 2.08E-01 1.13E+00 Ba-140
  • 8.08E-01 4.86E+00 La-140
  • 8.01E-02 1.43E+00 07/09/02 K-40 1.55E+03 9.10E+01 Cs-1 34 * - 6.26E+00 4.38E+00 Cs-1 37
  • 3.83E+00 3.47E+00 Ba-140
  • 2.66E+00 1.80E+01 La-140
  • 2.76E+00 5.13E+00 07/23/02 K-40 1.58E+03 8.20E+01 Cs-134
  • 9.08E-01 1.71 E+00 Cs-1 37
  • 5.05E-01 2.45E+00 Ba-140
  • 4.20E+00 1.33E+01 La-140 *- 4.98E-01 3.07E+00 08/13/02 K-40 1.48E+03 7.70E+01 Cs-134 * - 1.22E+00 2.19E+00 Cs-137 * - 5.60E-01 2.33E+00 Ba-140 *- 1.26E+00 1.14E+01 La-140
  • 6.51E-02 3.53E+00 08/27/02 K-40 1.39E+03 7.80E+01 Cs-1 34 * - 3.73E+00 2.39E+00 Cs-1 37 * - 5.41 E-01 2.42E+00 Ba-140 * - 1.56E+00 1.41E+01 La-140 * - 4.26E+00 5.07E+00 09/10/02 K-40 1.56E+03 9.1OE+01 Cs-1 34 * - 1.30E+01 5.07E+00 Cs-1 37
  • 1.37E+00 4.14E+00 Ba-140 * - 9.32E+00 2.09E+01 La-1 40
  • 6.58E+00 6.48E+00
  • Denotes a result less than the detection limit.

TABLE A-12.1 (Cont.)

GAMMA SPECTROMETRY OF MILK Results in pCilliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 64 09/24/02 K-40 1.54E+03 8.OOE+01 Cs-134 * - 2.17E-01 1.68E+00 Cs-1 37

  • 5.47E-01 2.34E+00 Ba-140
  • 1.19E+01 1.27E+01 La-140
  • 2.84E+00 3.83E+00 10/15/02 K-40 1.51E+03 6.40E+01 Cs-1 34 * - 2.66E-01 9.22E-01 Cs-137
  • 1.91E+00 1.53E+00 Ba-140
  • 6.92E+00 1.65E+01 La-140 *- 3.56E+00 5.30E+00 11/12/02 K-40 1.60E+03 1.03E+02 Cs-134
  • 1.07E+00 2.39E+00 Cs-1 37 * - 2.93E-01 2.31 E+00 Ba-140 * - 4.27E+00 1.23E+01 La-140 * - 9.34E-01 2.79E+00 12/10/02 K-40 1.64E+03 1.02E+02 Cs-134 * - 1.68E+01 2.97E+00 Cs-137
  • 3.06E+00 2.87E+00 Ba-140 * - 5.09E+00 1.18E+01 La-140
  • 5.35E-01 4.75E+00 I Denotes a result less than the detection limit.

TABLE A-12.2 GAMMA SPECTROMETRY OF MILK -

SUMMARY

Results in pCUliter NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE K-40 (I) 1.48E+03 1.11E+03 1.89E+03 54 54 Cs-134 (I) 1.48E+00 -2.19E+01 2.12E+01 54 0 Cs-137 (I) 1.13E+00 -2.53E+00 7.28E+00 54 0 Ba-140 (I) 2.01 E+00 -1.53E+01 1.44E+01 54 0 La-140 (I) 6.49E-02 -8.88E+00 6.58E+00 54 0 (I) Indicator Stations

TABLE A-13.1 1-131 IN BROADLEAF IN LIEU OF MILK Results inpCi/kg (wet)

COLLECTION OVERALL LOCATION DATE RESULT UNCERTAINTY 9G 01/15/02

  • 1.90E+00 2.47E+00 02/12/02 * - 9.OOE-01 6.19E+00 03/12/02
  • 8.60E+00 8.51 E+00 04/09/02
  • 1.80E+00 5.49E+00 05/07/02
  • 3.88E+00 3.44E+00 06/25/02 * - 3.56E+00 5.36E+00 07/23102
  • 1.80E-01 6.73E+00 08/27/02
  • 2.49E+00 5.04E+00 09/24/02
  • 6.51E-01 4.16E+00 10/15/02
  • 1.62E+00 4.51E+00 11/12/02 *-4.69E-01 6.14E+00 12/10/02
  • 5.40E+00 7.19E+00

' Denotes a result less than the detection limit.

TABLE A-13.2 1-131 IN BROADLEAF IN LIEU OF MILK -

SUMMARY

Results in pCiliter NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE 1-131 (I) 1.80E+00 -3.56E+00 8.60E+00 12 0 (I) Indicator Stations

Table A-14.1 GAMMA SPECTROMETRY OF BROADLEAF IN LIEU OF MILK Results in pCiVkilogram (wet)

Overall Location Collection Date Nuclide Result Uncertainty 9G 1/15/2002 Be-7 7.38E+01 2.13E+01 Cornchop Meeker K-40 6.46E+03 2.38E+02 Cs-1 34

  • 1.81 E+01 5.72E+00 Cs-1 37
  • 2.53E+00 5.39E+00 Ba-140 * - 2.30E+01 2.80E+01 La-140
  • 2.54E+01 3.23E+01 9G 2/12/2002 Be-7 * - 1.98E+01 1.61 E+02 Cornchop Meeker K-40 4.56E+03 2.05E+02 Cs-134
  • 1.22E+01 7.24E+00 Cs-1 37 * - 2.51 E-0I 3.90E+00 Ba-140 * - 3.07E+03 3.38E+03 La-140 * - 8.80E+01 1.06E+03 Th-228 * - 1.16E+01 5.29E+01 9G 3/12/2002 Be-7 7.57E+01 2.18E+01 Cornchop Meeker K-40 6.23E+03 2.33E+02 Cs-1 34
  • 2.01 E+00 2.75E+00 Ba-140
  • 2.12E+00 1.67E+01 La-140
  • 1.18E+01 8.06E+00 9G 4/9/2002 Be-7
  • 8.07E+01 4.66E+01 Cornchop Meeker K-40 6.43E+03 3.59E+02 Cs-1 34 *- 1.OOE+00 7.51 E+00 Cs-137
  • 4.88E+00 1.37E+01 Ba-140 * - 7.08E+00 7.39E+01 La-140 * - 2.72E+00 2.20E+01 Th-228
  • 9.95E+01 1.01 E+02 9G 5/7/2002 Be-7
  • 1.96E+01 1.25E+02 Grass Meeker K-40 9.28E+03 4.17E+02 Cs-1 34
  • 9.59E-01 5.46E+00 Cs-137 * - 1.18E+01 1.38E+01 Ba-140 * - 9.12E+00 6.80E+01 La-140 * - 1.33E+01 2.13E+01 Th-228
  • 1.52E+01 1.08E+02
  • Denotes a result less than the detection limit.

Table A-14.1 (cont.)

GAMMA SPECTROMETRY OF BROADLEAF IN LIEU OF MILK Results inpCVkilogram (wet)

Overall Location Collection Date Nuclide Result Uncertainty 9G 06/25/02 Be-7

  • 1.51 E+02 4.08E+01 Cornchop Meeker K-40 9.00E+03 3.52E+02 Cs-1 34
  • 3.49E+01 9.56E+00 Cs-137 * - 6.81E+00 5.95E+00 Ba-140
  • 2.21 E+00 4.19E+01 La-140
  • 7.21 E+01 6.39E+01 9G 07/23/02 Be-7 1.17E+02 2.98E+01 Grass Meeker K-40 1.30E+04 4.50E+02 Cs-134
  • 2.37E+00 5.40E+00 Ba-140
  • 3.50E+00 3.81 E+01 La-140 * - 4.22E+00 1.17E+01 Th-228
  • 1.39E+01 1.14E+01 9G 08/27/02 Be-7 1.74E+02 5.28E+01 Grass Meeker K-40 5.49E+03 2.55E+02 Cs-134
  • 4.57E+00 9.26E+00 Cs-1 37 *- 5.89E-01 5.91 E+00 Ba-140
  • 2.50E+01 6.70E+01 La-140
  • 1.50E+01 2.01 E+01 Th-228 *4.64E+01 2.97E+01 9G 09/24/02 Be-7
  • 1.65E+02 1.89E+02 Grass Meeker K-40 6.36E+03 5.40E+02 Cs-1 34
  • 2.69E+00 1.60E+01 Ba-140 * - 5.72E+01 2.56E+02 La-140
  • 7.53E+01 7.89E+01 Th-228 *- 1.17E+01 3.01 E+01 9G 10/15/02 Be-7 2.04E+02 6.95E+01 Comchop Meeker K-40 1.27E+04 2.72E+02 Cs-1 34 * - 2.66E+00 5.32E+00 Cs-1 37
  • 9.57E+00 9.72E+00 Ba-140 * - 3.19E+00 5.59E+01 La-140
  • 1.35E+01 1.62E+01 Th-228 2.77E+02 3.57E+01
  • Denotes a result less than the detection limit.

Table A-14.1 (cont.)

GAMMA SPECTROMETRY OF BROADLEAF IN LIEU OF MILK Results inpCilkilogram (wet)

Overall Location Collection Date Nuclide Result Uncertainty 9G 11/12/02 Be-7

  • 8.57E+01 3.38E+01 Cornchop Meeker K-40 3.53E+03 1.96E+02 Cs-1 34 * - 2.72E+00 4.61 E+00 Cs-1 37 * - 9.64E+00 6.35E+00 Ba-140
  • 1.42E+00 3.65E+01 La-140 * - 5.90E+00 1.19E+01 Th-228
  • 3.96E+00 1.35E+01 9G 12/10/02 Be-7
  • 4.24E+01 3.69E+01 Cornchop Meeker K-40 3.67E+03 1.86E+02 Cs-1 34 * - 2.63E+01 4.66E+00 Cs-1 37
  • 1.02E+00 4.51 E+00 Ba-140
  • 4.94E+00 1.98E+01 La-140
  • 4.22E+00 5.69E+00 Th-228 * - 4.86E+01 9.49E+01
  • Denotes a result less than the detection limit.

TABLE A-14.2 GAMMA SPECTROMETRY OF BROADLEAF IN LIEU OF MILK -

SUMMARY

Results in pCVkilogram (wet)

NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE Be-7 (C) 9.74E+01 -1.98E+01 2.04E+02 12 5 K-40 (C) 7.23E+03 3.53E+03 1.30E+04 12 12 Cs-134 (C) 3.54E+00 -2.63E+01 3.49E+01 12 0 Cs-137 (C) -3.35E-01 -1.18E+01 9.57E+00 12 0 Ba-140 (C) -2.62E+02 -3.07E+03 2.50E+01 12 0 La-140 (C) 3.74E-01 -8.80E+01 7.53E+01 12 0 Th-228 (C) 3.34E+01 -4.86E+01 2.77E+02 12 1 (C) Control Stations

TABLE A-15.1 GAMMA SPECTROMETRY OF ROOTS Results in pCi/kilogram (wet)

COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 9C 06/25/02 Cs-1 34

  • 6.41 E-02 3.49E+00 Peas (a) Cs-1 37 * - 1.22E+00 2.66E+00 1-131
  • 1.30E+00 1.25E+01 37 06/25/02 Cs-134 * - 7.08E-01 2.15E+00 Onions Cs-1 37
  • 3.29E+00 2.95E+00 1-131 * - 1.61E+00 5.45E+00 9C 07/23/02 Cs-I 34
  • 2.48E+00 2.29E+00 Potatoes Cs-1 37
  • 1.93E+00 3.47E+00 1-131 * - 2.54E+00 7.64E+00 37 07/23/02 Cs-134
  • 6.80E-01 1.80E+00 Potatoes Cs-1 37 * - 5.69E-01 2.64E+00 1-131 * - 2.16E+00 4.42E+00 9C 08/27/02 Cs-1 34
  • 4.71 E-01 5.14E+00 Potatoes Cs-1 37 * - 1.22E+00 1.18E+01 1-131 * - 1.20E+00 2.70E+01 37 08/27/02 Cs-1 34 * - 4.52E+00 4.98E+00 Potatoes Cs-137
  • 4.49E+00 5.OOE+00 1-131
  • 1.15E+01 1.30E+01 9C 09/24/02 Cs-1 34 * - 2.89E+00 2.96E+00 Onions Cs-1 37 * - 2.79E+04 1.07E+03 1-131
  • 9.03E-01 1.95E+01 37 09/24/02 Cs-1 34 * - 9.21E-01 4.I1 E+00 Onions Cs-I 37 * - 3.88E+00 6.88E+00 1-131
  • 1.96E+01 4.98E+01 (a) Sugar pea pods substituted for root.
  • Denotes a result less than the detection limit.

TABLE A-1 5.2 GAMMA SPECTROMETRY OF ROOTS -

SUMMARY

Results inpCiVkilogram (wet)

NUMBER NUMBER NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE Cs-1 34 (I) -1.37E+00 -4.52E+00 6.80E-01 4 0 Cs-134 (C) 3.18E-02 -2.89E+00 2.48E+00 4 0 Cs-137 (I) 8.33E-01 -3.88E+00 4.49E+00 4 0 Cs-137 (C) -6.98E+03 -2.79E+04 1.93E+00 4 0 1-131 (I) 6.83E+00 -2.16E+00 1.96E+01 4 0 1-131 (C) -3.84E-01 -2.54E+00 1.30E+00 4 0 (I) Indicator Stations (C) Control Stations

TABLE A-16.1 GAMMA SPECTROMETRY OF FRUIT Results in pCi/kilogram (wet)

COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 9C 06/25/02 Cs-1 34 * - 1.32E+01 4.79E+00 Cherries Cs-1 37 * - 1.65E+00 3.29E+00 1-131 * - 2.22E+00 7.46E+00 37 06/25/02 Cs-134

  • 1.41 E+01 5.OOE+00 Cherries Cs-I 37
  • 2.32E+00 4.82E+00 1-131 * - 6.68E+00 8.35E+00 9C 07/23/02 Cs-1 34 * - 3.28E+00 3.88E+00 Apricots Cs-137
  • 1.01E+00 1.61E+00 1-131
  • 3.23E+00 7.37E+00 37 07/23/02 Cs-134 * - 9.70E-02 1.75E+00 Apricots Cs-1 37 * - 2.46E-01 1.39E+00 1-131 * - 1.45E+00 5.41E+00 9C 08/27/02 Cs-1 34 * - 1.76E+01 1.30E+01 Pears Cs-1 37
  • 3.73E-01 1.09E+01 1-131 * - 1.80E+01 2.98E+01 37 08/27/02 Cs-1 34 * - 5.28E-01 3.59E+00 Pears Cs-137
  • 5.29E+00 4.01E+00 1-131
  • 3.51 E+00 1.07E+01 9C 09/24/02 Cs-I 34 * - 3.91E+00 3.42E+00 Apples Cs-1 37 * - 1.01E+00 2.44E+00 1-131 * - 2.13E+01 2.39E+01 37 09/24/02 Cs-134
  • 2.31 E+00 3.47E+00 Apples Cs-1 37
  • 4.OOE-01 3.80E+00 1-131
  • 1.86E+01 2.76E+01 91 09/27/02 Cs-1 34 * - 4.20E+00 1.10E+01 Apples Cs-I 37 * - 1.22E+00 2.28E+01 1-131
  • 6.46E+00 5.67E+01 Denotes a result less than the detection limit.

TABLE A-16.2 GAMMA SPECTROMETRY OF FRUIT -

SUMMARY

Results in pCikilogram (wet)

NUMBER NUMBER NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE -

Cs-1 34 (I) 2.32E+00 -4.20E+00 1.41E+01 5 0 Cs-1 34 (C) -9.50E+00 -1.76E+01 -3.28E+00 4 0 Cs-137 (I) 1.31 E+00 -1.22E+00 5.29E+00 5 0 Cs-137 (C) -3.19E-01 -1.65E+00 1.01 E+00 4 0 1-131 (I) 4.09E+00 -6.68E+00 1.86E+01 5 0 1-131 (C) -9.57E+00 -2.13E+01 3.23E+00 4 0 (I) Indicator Stations (C) Control Stations

TABLE A-17.1 GAMMA SPECTROMETRY OF VEGETABLES Results in pCi/kilogram (wet)

COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 9C 04/23/02 Cs-1 34

  • 7.82E-01 5.68E+00 Asparagus Cs-1 37
  • 7.41 E-01 6.09E+00 1-131 * - 4.21E+00 1.13E+01 37 04/23/02 Cs-1 34 *- 7.59E-01 3.09E+00 Asparagus Cs-1 37
  • 2.26E+00 5.17E+00 1-131
  • 4.91 E+00 8.16E+00 9C 05/21/02 Cs-134
  • 3.74E+00 4.64E+00 Asparagus Cs-137
  • 7.75E+00 5.92E+00 1-131 * - 6.04E+00 1.10E+01 37 05/21/02 Cs-1 34 * -1.15E+01 8.50E+00 Asparagus Cs-1 37
  • 7.62E+00 6.91 E+00 1-131
  • 1.12E+00 1.05E+01 9C 06/25/02 Cs-1 34
  • 2.05E+01 6.16E+00 Cabbage Cs-137
  • 1.09E+01 5.74E+00 1-131
  • 1.40E+00 1.02E+01 37 06/25/02 Cs-1 34
  • 3.38E+00 5.53E+00 Cabbage Cs-137
  • 3.03E+00 5.13E+00 1-131
  • 2.82E+00 9.26E+00 9C 07/23/02 Cs-134 *- 3.51 E+00 2.91 E+00 Greenbeans Cs-137 * - 8.54E-01 4.04E+00 1-131 * - 1.97E+00 9.21 E+00 37 07/23/02 Cs-I 34
  • 7.11E-01 3.11E+00 Greenbeans Cs-137 * - 1.35E+00 4.46E+00 1-131
  • 8.08E-01 1.07E+01 9C 08/27/02 Cs-134 *- 7.35E+01 1.08E+01 Greenbeans Cs-137 *- 1.09E+00 3.OOE+00 1-131 * - 4.98E+00 3.40E+01 37 08127/02 Cs-134 *- 1.88E+01 1.28E+01 Greenbeans Cs-137
  • 1.32E+01 9.97E+00 1-131 * - 2.83E+01 3.38E+01 Denotes a result less than the detection limit.

TABLE A-17.1 (cont.)

GAMMA SPECTROMETRY OF VEGETABLES Results in pCi/kilogram (wet)

COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 9C 09/24/02 Cs-1 34

  • 1.22E+00 2.90E+00 Cabbage Cs-1 37
  • 3.48E+00 3.40E+00 1-131
  • 1.41E+01 2.62E+01 37 09/24/02 Cs-134 * - 2.12E-02 2.27E+00 Greenbeans Cs-1 37
  • 2.52E+00 2.42E+00 1-131 * - 7.51E+00 1.56E+01
  • Denotes a result less than the detection limit.

TABLE A-17.2 GAMMA SPECTROMETRY OF VEGETABLES -

SUMMARY

Results in pClkilogram (wet)

NUMBER NUMBER NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE -

Cs-1 34 (I) -4.50E+00 -1.88E+01 3.38E+00 6 0 Cs-134 (C) -8.46E+00 -7.35E+01 2.05E+01 6 0 Cs-137 (I) 4.55E+00 -1.35E+00 1.32E+01 6 0 Cs-137 (C) 3.49E+00 -1.09E+00 1.09E+01 6 0 1-131 (I) -4.36E+00 -2.83E+01 4.91 E+00 6 0 1-131 (C) -2.83E-01 -6.04E+00 1.41 E+01 6 0 (I) Indicator Stations (C) Control Stations

ENERGY NORTHWEST - 2002 SPECIAL INTEREST TABLES

TABLE B-2.1 GAMMA SPECTROMETRY OF STORM DRAIN WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 101 12/28/01 - 01/07/02 Be-7

  • 4.25E+00 9.92E+00 K-40 * - 6.73E+00 1.21 E+01 Mn-54 * - 2.03E-01 9.76E-01 Co-58
  • 1.46E-01 1.07E+00 Fe-59
  • 2.16E-01 2.32E+00 Co-60 * - 2.40E-01 9.OOE-01 Zn-65 * - 2.35E+00 2.05E+00 Nb-95 *- 1.76E-01 1.02E+00 Zr-95 * - 1.01E+00 1.79E+00 Cs-1 34
  • 1.33E-01 6.26E-01 Cs-1 37
  • 2.30E-01 9.12E-01 Ba-140 * - 1.47E+01 1.07E+01 La-1 40
  • 3.57E+00 1.58E+01 Th-228 * - 1.73E-01 1.12E+00 01111/02 - 01/24/02 Be-7
  • 1.31E+01 1.59E+01 K-40
  • 1.28E-01 1.51 E+00 Co-58 * - 2.92E-01 1.82E+00 Fe-59
  • 2.17E+00 1.53E+00 Zn-65
  • 2.71 E-01 1.91 E+00 Nb-95 * - 9.79E-01 1.61 E+00 Zr-95
  • 2.07E+00 2.83E+00 Cs-1 34
  • 8.54E-01 1.63E+00 Ba-140 * - 3.89E+00 1.13E+01 La-140 * - 2.04E+00 3.72E+00 Ra-226 * - 2.OOE+01 2.21 E+01 Th-228
  • 1.63E+01 1.23E+01
  • Denotes a result less than the detection limit.

TABLE B-2.1 (Cont.)

GAMMA SPECTROMETRY OF STORM DRAIN WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 101 01/25/02 - 02/05102 Be-7

  • 2.12E+01 1.91 E+01 K-40 *- 2.77E+01 1.92E+01 Mn-54
  • 4.29E-01 2.01 E+00 Co-58
  • 1.87E-01 2.27E+00 Fe-59
  • 3.37E+00 4.19E+00 Co-60 *- 1.95E+00 1.97E+00 Zn-65
  • 2.84E-02 1.06E+00 Nb-95
  • 1.95E+00 1.93E+00 Zr-95
  • 1.61 E+00 3.42E+00 Cs-1 34
  • 5.55E-01 1.85E+00 Ba-140 *- 9.35E+00 1.50E+01 La-140 * - 1.86E+00 4.66E+00 Ra-226
  • 1.01E+01 1.41 E+01 02/07102 - 02/15/02 Be-7 * - 2.83E+00 1.51 E+01 K-40 * - 3.30E+01 1.42E+01 Mn-54
  • 2.57E-01 1.42E+00 Co-58 * - 7.82E-01 1.62E+00 Fe-59
  • 9.08E-01 9.51 E-01 Zn-65 * - 2.25E+00 1.96E+00 Nb-95 * - 6.70E-01 6.97E-01 Zr-95 * - 2.31E-01 2.54E+00 Cs-1 34 * - 1.50E+00 1.66E+00 Cs-1 37
  • 9.10E-02 7.07E-01 Ba-140
  • 5.70E+00 1.23E+01 La-140 * - 1.19E+00 4.25E+00 Ra-226 * - 1.17E+01 3.85E+01 Th-228 * - 1.95E+00 2.91 E+00

' Denotes a result less than the detection limit.

TABLE B-2.1 (Cont.)

GAMMA SPECTROMETRY OF STORM DRAIN WATER Results in pCiliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 101 02/27/02 - 03/06/02 Be-7

  • 1.29E+01 2.07E+01 K-40 * - 4.87E+01 3.53E+01 Mn-54
  • 1.23E-01 2.30E+00 Co-58
  • 1.04E-01 2.54E+00 Fe-59
  • 5.45E-01 2.24E+00 Zn-65
  • 6.02E-01 3.29E+00 Nb-95
  • 4.21 E-01 1.34E+00 Zr-95
  • 1.45E+00 3.85E+00 Cs-1 34 *- 5.50E-01 1.51 E+00 Cs-1 37
  • 1.16E+00 2.26E+00 Ba-140
  • 7.04E+00 1.44E+01 La-140
  • 2.08E+00 2.09E+00 03112/02 - 03/21/02 Be-7
  • 1.11E+01 1.74E+01 K-40
  • 2.61 E-0I 1.80E+00 Co-58 *- 1.05E+00 1.94E+00 Fe-59
  • 1.69E-01 1.72E+00 Zn-65
  • 7.91 E-02 1.14E+00 Nb-95
  • 6.97E-01 1.71 E+00 Zr-95 *- 8.29E-01 2.96E+00 Cs-134 *- 1.39E+00 1.95E+00 Cs-1 37
  • 6.30E-01 1.70E+00 Ba-140
  • 7.91 E+00 1.1 OE+01 La-I 40
  • 9.79E+00 1.27E+01
  • Denotes a result less than the detection limit.

TABLE B-2.1 (Cont.)

GAMMA SPECTROMETRY OF STORM DRAIN WATER Results inpCUliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 101 03/22/02 - 04/02/02 Be-7

  • 1.72E+00 1.92E+01 K-40 *- 1.61E+00 2.55E+01 Mn-54
  • 5.73E-01 1.96E+00 Co-58
  • 7.16E-01 2.02E+00 Fe-59
  • 4.89E-02 1.81 E+00 Zn-65 * - 5.41 E+00 4.75E+00 Nb-95 * - 1.37E+00 2.06E+00 Zr-95 * - 1.18E+00 3.58E+00 Cs-1 34 *- 5.11E-01 1.39E+00 Cs-1 37
  • 5.41 E-01 2.03E+00 Ba-140
  • 1.49E+00 1.12E+01 La-140
  • 1.97E+00 2.23E+00 04/03/02 - 04/14/02 Be-7 * - 1.79E+01 2.73E+01 K-40 * - 8.90E+01 3.09E+01 Mn-54 * - 1.26E+00 3.02E+00 Co-58 * - 1.58E+00 2.72E+00 Fe-59 * - 2.63E+00 5.83E+00 Co-60 * - 4.09E-01 1.74E+00 Zn-65 * - 1.99E-01 2.46E+00 Nb-95
  • 2.54E+00 2.76E+00 Zr-95 * - 5.79E-01 4.87E+00 Cs-134 * - 8.65E-01 2.28E+00 Cs-137 * - 9.35E-01 1.52E+00 Ba-140 * - 8.65E+00 1.69E+01 La-140
  • 8.18E+00 1.93E+01
  • Denotes a result less than the detection limit.

TABLE B-2.1 (Cont.)

GAMMA SPECTROMETRY OF STORM DRAIN WATER Results in pCiliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 101 04/15/02 - 04/17/02 Be-7

  • 1.44E+01 2.45E+01 K-40
  • 1.95E+00 2.37E+00 Co-58 *- 1.98E+00 2.82E+00 Fe-59
  • 1.23E+00 1.32E+00 Zn-65 * - 9.36E-01 2.02E+00 Nb-95
  • 1.89E+00 2.32E+00 Zr-95 *- 1.90E+00 4.13E+00 Cs-134 *- 1.24E+00 2.61 E+00 Cs-1 37 *- 1.14E+00 2.01 E+00 Ba-140
  • 3.10E+01 2.11E+01 La-I 40
  • 1.38E+01 1.65E+01 04/25/02 - 05/01/02 Be-7
  • 5.46E-01 2.28E+01 K-40 * - 4.72E+01 2.86E+01 Mn-54
  • 8.94E-01 2.36E+00 Co-58 * - 3.80E+00 2.62E+00 Fe-59
  • 6.38E-02 2.28E+00 Zn-65 *- 1.00E+00 1.61 E+00 Nb-95
  • 2.29E+00 2.46E+00 Zr-95 * - 3.73E-01 3.88E+00 Cs-134
  • 1.35E-02 2.25E+00 Ba-140
  • 4.61 E+00 1.36E+01 La-140 * - 6.31E+00 4.85E+00 Ra-226 *- 1.44E+01 2.01E+01 Th-228
  • 7.70E+00 1.69E+01
  • Denotes a result less than the detection limit.

TABLE B-2.1 (Cont.)

GAMMA SPECTROMETRY OF STORM DRAIN WATER Results in pCilliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 101 05/01/02 - 05/08/02 Be-7

  • 8.72E+00 1.30E+01 K-40
  • 1.43E+00 1.34E+00 Co-58 * - 1.06E+00 1.45E+00 Fe-59
  • 4.29E-01 1.42E+00 Zn-65 * - 6.82E-01 1.53E+00 Nb-95
  • 5.80E-01 1.23E+00 Zr-95
  • 1.03E+00 2.16E+00 Cs-1 34
  • 8.54E-01 1.48E+00 Cs-1 37 * - 5.88E-01 7.66E-01 Ba-140 * - 5.63E+00 7.90E+00 La-140 *- 1.23E+00 1.45E+00 Ra-226 * - 8.57E+00 1.59E+01 Th-228 * - 8.80E-02 5.15E+00 05/08102 - 05117/02 Be-7
  • 1.09E+01 1.51 E+01 K-40
  • 3.39E+01 1.64E+01 Mn-54 * .51 E-01 1.50E+00 Co-58 * - 6.32E-01 1.64E+00 Fe-59
  • 1.40E+00 3.28E+00 Co-60 * - 3.09E-01 1.24E+00 Zn-65 * - 2.26E-01 7.92E-01 Nb-95
  • 1.26E+00 1.42E+00 Zr-95 * - 2.24E+00 2.53E+00 Cs-1 34
  • 5.81 E-01 6.97E-01 Ba-140 * - 5.38E+00 8.68E+00 La-1 40
  • 1.75E-01 9.96E+00
  • Denotes a result less than the detection limit.

TABLE B-2.1 (Cont.)

GAMMA SPECTROMETRY OF STORM DRAIN WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 101 05/30/02 - 06/20102 Be-7

  • 2.57E+00 8.40E+00 K-40
  • 8.36E+00 1.30E+01 Mn-54 * - 4.65E-01 7.69E-01 Co-58
  • 1.86E-01 9.38E-01 Fe-59
  • 9.80E-01 1.99E+00 Co-60 * - 4.45E-02 8.80E-01 Zn-65
  • 4.95E-01 1.24E+00 Nb-95
  • 6.21 E-01 8.37E-01 Zr-95
  • 1.49E+00 1.47E+00 Cs-I 34
  • 9.20E-02 7.03E-01 Cs-I 37
  • 4.52E-01 8.84E-01 Ba-140 * - 7.01 E-01 5.10E+00 La-140
  • 3.41 E-02 1.68E+00 Ra-226 * - 1.01E+01 1.54E+01 Th-228 * - 5.38E-01 2.01 E+00 06/20/02 - 06/28/02 Be-7 * - 6.63E+00 1.40E+01 K-40 * - 6.01E+00 1.33E+01 Mn-54
  • 1.33E+00 1.28E+00 Co-58 * - 8.93E-01 1.52E+00 Fe-59
  • 4.46E+00 3.05E+00 Co-60 * - 8.50E-01 1.05E+00 Zn-65 * - 5.98E-01 1.67E+00 Nb-95 * - 4.49E-01 3.83E-01 Zr-95 * - 1.43E+00 2.29E+00 Cs-1 34
  • 3.74E+00 1.36E+00 Cs-1 37 * - 2.10E-03 7.36E-01 Ba-140 * - 1.57E+01 1.42E+01 La-140 * - 1.08E+00 4.35E+00 Ra-226 * - 1.62E+01 4.89E+01 Th-228
  • 3.26E+00 6.05E+00
  • Denotes a result less than the detection limit.

TABLE B-2.1 (Cont.)

GAMMA SPECTROMETRY OF STORM DRAIN WATER Results in pCilliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 101 06/28/02 - 07/06/02 Be-7 - 1.18E+00 2.70E+01 K-40

  • 1.42E+01 2.79E+01 Mn-54 * - 4.67E-01 2.87E+00 Co-58 * - 1.79E+00 3.OOE+00 Fe-59
  • 6.29E-01 2.62E+00 Zn-65 * - 6.36E-01 3.52E+00 Nb-95 * - 1.00E-02 1.06E+00 Zr-95 * - 7.60E-01 4.87E+00 Cs-1 34 * - 7.17E+00 3.34E+00 Cs-1 37 * - 6.78E-01 2.68E+00 Ba-140 * - 1.32E+01 1.85E+01 La-140 * - 6.05E-01 6.13E+00 Ra-226
  • 1.48E+01 1.88E+01 07/08/02 - 07/16/02 Be-7
  • 9.90E+00 2.88E+01 K-40
  • 1.94E+01 4.87E+01 Mn-54 *- 1.45E+00 3.31 E+00 Co-58
  • 4.56E-01 3.38E+00 Fe-59 *- 3.68E+00 6.66E+00 Co-60 *- 2.10E+00 3.19E+00 Zn-65
  • 1.23E+00 5.63E+00 Nb-95
  • 4.50E+00 3.07E+00 Zr-95
  • 3.85E+00 5.27E+00 Cs-1 34
  • 1.46E+00 2.67E+00 Cs-1 37
  • 1.24E+00 2.94E+00 Ba-140 *- 4.76E+00 1.80E+01 La-140
  • 2.17E-01 4.44E+01 Th-228 *- 7.44E-01 5.90E+00
  • Denotes a result less than the detection limit.

TABLE B-2.1 (Cont.)

GAMMA SPECTROMETRY OF STORM DRAIN WATER Results inpCiliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 101 07/16102 - 07/22/02 Be-7

  • 1.48E+01 2.16E+01 K-40 *- 1.87E+01 3.14E+01 Mn-54 *- 3.54E+00 2.39E+00 Co-58
  • 7.29E-01 2.41 E+00 Fe-59 *- 5.59E+00 5.26E+00 Co-60 *- 1.23E-01 2.21 E+00 Zn-65 *- 9.52E+00 5.81 E+00 Nb-95
  • 1.34E+00 2.24E+00 Zr-95 *- 1.38E+00 3.87E+00 Cs-1 34 *- 2.77E-01 2.15E+00 Cs-1 37
  • 1.26E+00 2.34E+00 Ba-140 *- 7.97E+00 1.51 E+01 La-140 *- 1.04E+00 5.22E+00 Ra-226 *- 1.68E+01 3.49E+01 Th-228
  • 2.74E+00 2.35E+00 07/27/02 - 09/02/02 Be-7
  • 5.38E+00 2.46E+01 K-40 *- 6.62E+00 3.29E+01 Mn-54 *- 2.32E+00 2.60E+00 Co-58 *- 3.14E+00 2.81 E+00 Fe-59 *- 9.78E-01 5.71 E+00 Co-60 *- 7.51 E-0I 2.44E+00 Zn-65 *- 5.07E+00 4.53E+00 Nb-95 *- 1.60E+00 1.51 E+00 Zr-95
  • 3.55E+00 4.35E+00 Cs-I 34
  • 6.52E-01 2.25E+00 Cs-I 37
  • 8.37E-02 2.40E+00 Ba-140 *- 1.13E+01 2.1 OE+01 La-140
  • 1.30E+01 3.49E+01 Th-228 *- 2.28E+00 5.18E+00
  • Denotes a result less than the detection limit.

TABLE B-2.1 (Cont.)

GAMMA SPECTROMETRY OF STORM DRAIN WATER Results inpCiAiter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 101 09104/02 - 10/02/02 Be-7

  • 2.48E+00 1.32E+01 K-40 - 1.53E+01 1.26E+01 Mn-54 *- 3.85E-01 1.07E+00 Co-58
  • 3.57E-01 1.28E+00 Fe-59
  • 6.96E-01 9.53E-01 Zn-65 *- 4.13E-02 1.53E+00 Nb-95
  • 1.16E+00 1.21 E+00 Zr-95
  • 1.68E+00 2.15E+00 Cs-1 34
  • 3.84E-01 6.88E-01 Cs-1 37
  • 2.26E-01 9.91 E-01 Ba-140
  • 1.74E+01 2.18E+01 La-140
  • 7.05E+00 1.80E+01 Th-228 *- 2.21 E-01 2.32E+00 10/02/02 - 11105/02 Be-7
  • 5.25E+00 2.22E+01 K-40 * - 1.51 E+01 3.18E+01 Mn-54
  • 1.38E+00 2.42E+00 Co-58
  • 1.64E+00 2.62E+00 Fe-59 * - 3.14E+00 5.48E+00 Co-60
  • 5.83E-01 1.71 E+00 Zn-65
  • 3.36E+00 3.93E+00 Nb-95
  • 7.69E-01 1.68E+00 Zr-95
  • 1.52E+00 3.95E+00 Cs-1 34
  • 2.56E+00 1.29E+00 Ba-140
  • 4.87E+00 1.35E+01 La-140
  • 9.74E+00 5.53E+00
  • Denotes a result less than the detection limit.

TABLE B-2.1 (Cont.)

GAMMA SPECTROMETRY OF STORM DRAIN WATER Results inpCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 101 11/05/02 - 12/03/02 Be-7

  • 1.20E+01 1.66E+01 K-40 * - 4.06E+00 4.54E+01 Mn-54 * - 2.28E+00 2.37E+00 Co-58
  • 5.65E-01 2.OOE+00 Fe-59 * - 1.53E+00 4.26E+00 Co-60 * - 1.15E-02 2.08E+00 Zn-65 * - 1.01E+01 4.66E+00 Nb-95 * - 2.30E+00 2.07E+00 Zr-95 * - 5.19E-01 3.56E+00 Cs-1 34
  • 1.55E-01 2.03E+00 Cs-1 37 * - 2.31E+00 2.47E+00 Ba-140
  • 4.92E+00 1.13E+01 La-140 * - 1.22E+00 3.44E+00 Ra-226 * - 4.04E+01 5.82E+01 Th-228
  • 1.29E+02 4.07E+01 12/03/02 - 01/02/03 Be-7
  • 5.28E+00 8.33E+00 K-40
  • 3.03E-01 9.82E-01 Co-58 - 6.81 E-02 9.49E-01 Fe-59
  • 8.93E-01 1.06E+00 Zn-65 * - 501 E+00 2.21 E+00 Nb-95
  • 1.09E+00 9.84E-01 Zr-95 * - 5.39E-01 1.74E+00 Cs-1 34 * - 3.06E+00 1.01 E+00 Cs-137
  • 1.04E+00 1.68E+00 Ba-140
  • 9.46E-02 4.91 E+00 La-140 * - 2.66E-01 1.48E+00 Ra-226
  • 7.29E+00 3.68E+01 Th-228 * - 1.29E+02 2.48E+01
  • Denotes a result less than the detection limit.

TABLE B-2.2 GAMMA SPECTROMETRY OF STORM DRAIN WATER -

SUMMARY

Results in pCi/liter NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE Station 101 - Ouffall Be-7 (I) 5.82E+00 -1.79E+01 2.12E+01 22 K-40 (I) -8.69E+00 -8.90E+01 3.39E+01 22 Mn-54 (I) -1.44E-01 -3.54E+00 1.95E+00 22 Co-58 (I) -5.45E-01 -3.80E+00 1.64E+00 22 Fe-59 (I) 1.06E+00 -5.59E+00 4.85E+00 22 Co-60 (I) 7.17E-02 -2.1 OE+00 2.17E+00 22 Zn-65 (I) -1.73E+00 -1.01 E+01 3.36E+00 22 Nb-95 (I) 6.16E-01 -2.30E+00 4.50E+00 22 Zr-95 (I) -8.27E-02 -3.55E+00 3.85E+00 22 Cs-1 34 (I) 7.14E-03 -7.17E+00 4.87E+00 22 Cs-1 37 (I) 2.67E-01 -2.31 E+00 2.56E+00 22 Ba-140 (I) -7.36E-01 -1.57E+01 3.10E+01 22 LA-140 (I) 2.71 E-01 -6.31 E+00 8.17E+00 22 Ra-226 (I) -5.13E+00 -6.77E+01 9.57E+01 22 Th-228 (I) 4.30E+00 -1.29E+02 1.29E+02 22 (I) Indicator Station

TABLE B-3.1 GROSS BETA IN STORM DRAIN WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 101 12/28/01 - 01/07/02 4.60E+00 2.OOE+00 01/11/02 - 01/24/02 3.90E+00 1.50E+00 01/25/02 - 02/05/02

  • 2.20E+00 1.86E+00 02/07/02 - 02/15/02 4.1 OE+00 2.1OE+00 02/27/02 - 03/06/02
  • 2.50E+00 1.86E+00 03/12/02 - 03/21/02 4.1 OE+00 2.OOE+00 03/22/02 - 04/02/02
  • 1.70E+00 1.88E+00 04/03/02 - 04/14/02
  • 1.20E+00 1.86E+00 04/15/02 - 04/17/02
  • 5.72E-01 1.71 E+00 04/25/02 - 05/01/02 6.50E+00 2.40E+00 05/01/02 - 05/08/02 7.1 3E+00 2.40E+00 05/08/02 - 05117/02
  • 2.66E+00 2.07E+00 05/30/02 - 06/20/02 * - 1.70E+00 1.99E+00 06/20102 - 06/28/02 * - 1.29E+00 2.02E+00 06/28/02 - 07/06/02 1.97E+00 1.62E+00 07/08102 - 07/16/02
  • 2.29E+00 2.05E+00 07/16102 - 07/22/02
  • 1.68E+00 2.01 E+00 07/27/02 - 09/02/02
  • 1.11E+00 2.16E+00 09/04/02 - 10/02/02
  • 5.69E-01 1.97E+00 10/21/02 - 11/05/02
  • 2.76E+00 2.1 OE+00 11/05/02 - 12103/02 3.54E+00 1.29E+00 12/31/02 - 01/02/03 5.36E+00 2.29E+00
  • Denotes a result less than the detection limit.

TABLE B-3.2 GROSS BETA IN STORM DRAIN WATER -

SUMMARY

Results inpCiAiter NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE Station 101- Ouffall Gross Beta (I) 2.61E+00 -1.70E+00 7.13E+00 22 9 (I) Indicator Station

TABLE B-4.1 TRITIUM IN STORM DRAIN WATER Results in pCiAiter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 101 12/28/01 - 01/07/02 1.30E+03 1.00E+02 01/11/02 - 01/24/02 3.50E+02 7.00E+01 01/25/02 - 02/05/02 1.80E+02 6.OOE+01 02/07/02 - 02/15/02 1.OOE+03 1.OOE+02 02/27/02 - 03/06/02 1.98E+03 1.10E+02 03/12/02 - 03/21/02 6.11E+03 1.80E+02 03/22/02 - 04/02/02 3.37E+03 1.30E+02 04/03/02 - 04/14/02 3.14E+03 1.40E+02 04/15/02 - 04/17/02 6.27E+02 8.10E+01 04/25/02 - 05/01/02 1.81 E+03 1.1OE+02 05/01/02 - 05/08/02 1.96E+02 6.20E+01 05/08/02 - 05/17/02

  • 7.58E+01 6.06E+01 05/30/02 - 06/20/02 1.15E+03 9.03E+01 06/20/02 - 06/28/02 1.12E+03 9.05E+01 06/28/02 - 07/06/02 1.06E+03 8.96E+01 07/08/02 - 07/16/02 1.16E+03 1.04E+02 07/16/02 - 07/22/02 1.37E+03 1.08E+02 07/27/02 - 09/02/02 9.54E+02 1.05E+02 09/04/02 - 10/02/02 7.04E+02 1.34E+02 10/21/02 - 11/05/02 2.76E+03 1.79E+02 11/05/02 - 12/03/02 8.77E+03 4.57E+02 12/31/02 - 01/02/03 1.40E+04 3.59E+02
  • Denotes a result less than the detection limit.

TABLE B-4.2 TRITiUM IN STORM DRAIN WATER -

SUMMARY

Results in pCi/liter NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLE POSITIVE Station 101 - Ouffall H-3 (I) 2.42E+03 7.58E+01 1.40E+04 22 21 (I) Indicator Station

TABLE B-5.1 GROSS ALPHA IN SANITARY WASTE TREATMENT WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 102A 1/2/2002 - 2/512002

  • 7.30E-01 1.79E+00 2/5/2002 - 3/5/2002
  • 2.30E-01 1.1OE+00 315/2002 - 412/2002
  • 9.80E-01 2.76E+00 4/2/2002 - 517/2002 * - 2.46E+00 2.95E+00 5/7/2002 - 6/4/2002
  • 2.82E+00 3.1 5E+00 6/4/2002 - 7/2/2002
  • 3.09E+00 4.37E+00 7/2/2002 - 8/6/2002 * - 1.89E+00 1.69E+00 8/6/2002 - 9/4/2002 * - 6.69E-01 2.68E+00 9/3/2002 - 10/1/2002 *- 2.02E+00 1.90E+00 10/1/2002 - 11/512002 *- 3.46E+00 4.24E+00 11/5/2002 - 12/3/2002
  • 2.63E+00 4.05E+00 12/3/2002 - 1/3/2003
  • 2.32E+00 1.99E+00 102C 1/16/2002 * - 1.20E+00 2.1 7E+00 1/16/2002 * - 4.20E-01 2.55E+00
  • Denotes a result less than the detection limit.

TABLE B-5.2 GROSS ALPHA IN SANITARY WASTE TREATMENT WATER -

SUMMARY

Results in pCi/liter NUMBER NUMBER NUCLIDE jWERAGE LOW HIGH SAMPLES POSITIVE 102A - FFTF Effluent Gross Alpha (I) 1.92E-01 -3.46E+00 3.09E+00 12 0 102C - Prior to Discharge Gross Alpha (I) -8.1OE-01 -1.20E+00 -4.20E-01 2 0 (I) Indicator Stations

TABLE B-6.1 GROSS BETA IN SANITARY WASTE TREATMENT WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY 102A 1/2/2002 - 2/5/2002 3.20E+01 4.00E+00 2/5/2002 - 3/5/2002 3.10E+01 2.OOE+00 3/5/2002 - 4/2/2002 3.OOE+01 4.OOE+00 4/2/2002 - 5/7/2002 3.22E+01 4.50E+00 5/7/2002 - 6/4/2002 2.28E+01 3.60E+00 6/4/2002 - 7/2/2002 2.78E+01 4.38E+00 7/2/2002 - 8/6/2002 2.24E+01 3.66E+00 8/6/2002 - 9/4/2002 2.OOE+01 3.57E+00 9/3/2002 - 10/1/2002 2.25E+01 3.OOE+00 10/1/2002 - 11/5/2002 3.86E+01 4.80E+00 11/512002 - 1213/2002 3.38E+01 4.18E+00 12/312002 - 1/3/2003 3.22E+01 4.08E+00 102C 1/16/2002 5.70E+01 5.OOE+00 1/16/2002 6.10E+01 6.OOE+00

TABLE B-6.2 GROSS BETA IN SANITARY WASTE TREATMENT WATER -

SUMMARY

Results in pCi/liter NUMBER NUMBER NUCLIDE ANVERAGE LOW HIGH SAMPLES POSITIVE 102A - FFTF Effluent Gross Beta (I) 2.88E+01 2.OOE+01 3.86E+01 12 12 102C - Prior to Discharge Gross Beta (I) 5.90E+01 5.70E+01 6.1OE+01 2 2

() Indicator Stations

TABLE B-7.1 GAMMA SPECTROMETRY OF SANITARY WASTE TREATMENT WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 102A 1/2/2002 - 2/5/2002 Be-7

  • 9.84E+00 1.67E+01 K-40 4.56E+01 2.30E+01 Mn-54 * - 9.75E-01 1.54E+00 Co-58 * - 4.74E-01 1.78E+00 Fe-59
  • 1.90E-01 1.45E+00 Zn-65 * - 5.69E+00 3.60E+00 Nb-95 * - 8.67E-01 1.70E+00 Zr-95 * - 1.69E+00 2.99E+00 Cs-1 34
  • 7.21 E-02 9.87E-01 Cs-1 37 * - 3.24E-01 8.42E-01 Ba-140 * - 5.73E+00 1.93E+01 La-140
  • 1.01E+01 2.24E+01 Th-228 * - 1.17E+00 1.43E+00 2/5/2002 - 3/5/2002 Be-7
  • 2.14E+00 1.1OE+01 K-40 3.36E+01 1.51E+01 Mn-54 * - 5.96E-01 9.OOE-01 Co-58 * - 1.04E+00 1.16E+00 Fe-59
  • 1.05E+00 1.95E+00 Co-60 * - 5.06E-01 8.85E-01 Zn-65
  • 1.59E-01 1.30E+00 Nb-95
  • 1.24E+00 1.06E+00 Zr-95 * - 7.92E-01 1.88E+00 Cs-1 34 * - 1.02E-01 5.73E-01 Cs-1 37
  • 2.89E-01 8.52E-01 Ba-140 * - 2.16E+00 1.94E+01 La-140 * - 3.35E+00 6.92E+00 Ra-226 * - 4.12E+00 1.43E+01 Th-228 * - 3.11E-01 9.67E-01
  • Denotes a result less than the detection limit.

TABLE B-7.1 (cont.)

GAMMA SPECTROMETRY OF SANITARY WASTE TREATMENT WATER Results in pCiliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 102A 3/5/2002 - 4/2/2002 Be-7 * - 1.00E+01 3.78E+01 K-40

  • 3.81E-01 4.25E+00 Co-58 *- 7.34E-01 4.40E+00 Fe-59 *- 1.78E+00 8.45E+00 Co-60 *- 1.79E+00 3.77E+00 Zn-65
  • 1.17E-01 2.28E+00 Nb-95
  • 2.11 E+00 3.95E+00 Zr-95 *- 4.04E-01 6.96E+00 Cs-1 34
  • 4.01 E+00 4.46E+00 Cs-1 37
  • 1.57E+00 3.98E+00 Ba-1 40
  • 1.13E+00 2.16E+01 La-140
  • 2.96E+01 2.99E+01 4/2/2002 - 5/7/2002 Be-7
  • 2.48E+00 1.60E+01 K-40
  • 7.60E-01 1.71 E+00 Co-58 * - 1.63E-01 9.73E-01 Fe-59
  • 1.20E+00 2.17E+00 Co-60 * - 1.12E+00 1.69E+00 Zn-65 * - 3.45E-01 8.84E-01 Nb-95
  • 2.27E+00 1.57E+00 Zr-95 * - 3.31E-01 2.80E+00 Cs-134
  • 3.04E+00 1.83E+00 Cs-137 * - 1.41E-01 1.70E+00 Ba-1 40
  • 1.35E+00 8.76E+00 La-140
  • 1.14E+01 1.23E+01
  • Denotes a result less than the detection limit.

TABLE B-7.1 (cont.)

GAMMA SPECTROMETRY OF SANITARY WASTE TREATMENT WATER Results inpCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 102A 5/7/2002 - 6/4/2002 Be-7

  • 2.73E+00 2.08E+01 K-40
  • 1.98E+01 3.01 E+01 Mn-54 * - 5.10E-01 2.27E+00 Co-58
  • 8.65E-01 2.20E+00 Fe-59
  • 9.73E-02 1.88E+00 Zn-65 * - 4.63E+00 4.98E+00 Nb-95 * - 9.20E-01 2.20E+00 Zr-95 * - 1.51E+00 3.82E+00 Cs-134 * - 6.70E-02 1.39E+00 Cs-I 37 * - 7.50E-02 2.31 E+00 Ba-140 * - 1.85E+01 1.39E+01 La-140
  • 2.99E-01 2.88E+00 Ra-226 * - 7.52E+00 3.10E+01 Th-228 * - 4.64E-01 1.97E+00 614/2002 - 7/2/2002 Be-7
  • 7.71 E+00 1.71 E+01 K-40 *- 1.90E+01 1.99E+01 Mn-54
  • 1.15E+00 1.83E+00 Co-58 *- 7.23E-01 1.96E+00 Fe-59
  • 3.48E+00 3.75E+00 Co-60 *- 1.51E+00 1.81 E+00 Zn-65 *- 3.23E+00 2.36E+00 Nb-95
  • 8.92E-01 1.67E+00 Zr-95
  • 1.18E+00 2.99E+00 Cs-134
  • 6.10E-01 1.77E+00 Ba-140
  • 5.09E+00 1.07E+01 La-140
  • 4.91 E+00 1.32E+01

' Denotes a result less than the detection limit.

TABLE B-7.1 (cont.)

GAMMA SPECTROMETRY OF SANITARY WASTE TREATMENT WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 102A 7/2/2002 - 8/6/2002 Be-7

  • 6.04E+00 2.54E+01 K-40
  • 1.60E-01 2.66E+00 Co-58 * - 7.76E-01 1.57E+00 Fe-59
  • 2.95E+00 5.86E+00 Co-60 * - 1.29E+00 2.69E+00 Zn-65 * - 8.40E-02 2.61 E+00 Nb-95
  • 4.41 E+00 2.86E+00 Zr-95
  • 3.37E+00 3.82E+00 Cs-1 34
  • 1.21 E+00 2.47E+00 Ba-140 * - 1.12E+01 1.94E+01 La-140
  • 2.62E+00 4.32E+00 8/6/2002 - 9/4/2002 Be-7
  • 1.46E+01 1.20E+01 K-40
  • 1.60E-01 9.55E-01 Co-58 * - 5.39E-01 1.17E+00 Fe-59
  • 6.25E+00 2.67E+00 Co-60 * - 4.81 E-0I 1.16E+00 Zn-65 * - 1.80E-02 1.16E+00 Nb-95
  • 1.34E+00 1.18E+00 Zr-95 *- 1.93E+00 2.13E+00 Cs-1 34
  • 5.27E-01 1.13E+00 Ba-140 *- 1.20E+01 1.09E+01 La-140 * - 2.77E+00 3.51 E+00 Ra-226 * - 1.17E+00 1.57E+01 Th-228
  • 1.36E-02 1.97E+00
  • Denotes a result less than the detection limit.

TABLE B-7.1 (cont.)

GAMMA SPECTROMETRY OF SANITARY WASTE TREATMENT WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 102A 9/3/2002 - 10/112002 Be-7 *- 2.38E+00 6.74E+00 K-40

  • 9.57E-02 6.13E-01 Co-58
  • 2.05E-01 6.69E-01 Fe-59 *- 2.17E-01 1.53E+00 Co-60 * - 1.45E+04 5.57E+02 Zn-65 *- 1.16E+00 1.32E+00 Nb-95 *- 3.73E-01 7.09E-01 Zr-95
  • 2.52E-01 1.22E+00 Cs-I 34 *- 8.91E-01 6.22E-01 Cs-1 37 *- 1.1OE+04 4.21 E+02 Ba-140 *- 9.06E-01 5.93E+00 La-140 *- 6.89E-01 1.93E+00 Ra-226
  • 2.35E-03 7.79E+00 10/1/2002 - 11/5/2002 Be-7 * - 3.62E+00 2.72E+01 K-40 * - 2.83E+01 4.51 E+01 Mn-54 * - 1.91E+00 3.13E+00 Co-58 * - 6.30E-01 3.07E+00 Fe-59
  • 5.1 OE+00 6.34E+00 Co-60 * - 1.80E+00 3.02E+00 Zn-65
  • 3.83E-02 5.20E+00 Nb-95
  • 1.46E+00 2.84E+00 Zr-95
  • 5.67E-01 5.15E+00 Cs-I 34 * - 2.11E+00 2.75E+00 Cs-I 37
  • 2.47E+00 2.93E+00 Ba-140 * - 6.92E+00 1.64E+01 La-140 * - 2.29E+00 6.02E+00 Ra-226 * - 1.62E+01 4.21E+01 Th-228 * - 9.95E-01 6.30E+00
  • Denotes a result less than the detection limit.

TABLE B-7.1 (cont.)

GAMMA SPECTROMETRY OF SANITARY WASTE TREATMENT WATER Results in pCilliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 102A 11/5/2002 - 12/3/2002 Be-7 * - 6.54E+00 1.57E+01 K-40 1.35E+02 6.19E+01 Mn-54 * - 5.70E-01 1.70E+00 Co-58

  • 8.93E-02 1.73E+00 Fe-59 * - 3.40E+00 3.54E+00 Co-60 * - 7.01 E-02 1.88E+00 Zn-65 * - 2.75E+00 3.50E+00 Nb-95 * - 1.10E+00 1.87E+00 Zr-95
  • 1.77E-02 3.05E+00 Cs-1 34
  • 3.64E-01 1.62E+00 Cs-1 37
  • 1.87E+00 1.80E+00 Ba-140 * - 4.94E-01 8.96E+00 La-140 * - 5.51E-01 3.11 E+00 Ra-226
  • 5.85E+00 7.72E+01 Th-228 * - 1.06E+02 3.84E+01 12/3/2002 - 1/3/2003 Be-7 * - 4.84E+00 1.04E+01 K-40
  • 4.02E+01 3.01 E+01 Mn-54 * - 7.14E-01 1.17E+00 Co-58
  • 5.51 E-01 1.1OE+00 Fe-59
  • 1.62E+00 2.35E+00 Co-60 * - 3.28E-01 1.13E+00 Zn-65 * - 2.17E+00 2.48E+00 Nb-95
  • 1.06E-02 1.12E+00 Zr-95 * - 4.79E-01 2.05E+00 Cs-1 34 * - 3.92E+00 1.16E+00 Cs-137 * - 2.21E-01 1.15E+00 Ba-140 * - 4.96E-01 5.27E+00 La-140 * - 1.29E+00 1.79E+00 Ra-226 * - 2.43E+01 3.25E+01 Th-228
  • 1.82E+01 2.73E+01

^ Denotes a result less than the detection limit.

TABLE B-7.1 (cont.)

GAMMA SPECTROMETRY OF SANITARY WASTE TREATMENT WATER Results inpCiiter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 102B 1/16/2002 Be-7 * - 6.11E+00 9.79E+00 Monthly K40 * - 3.66E+00 1.61E+01

'Headworks Mn-54

  • 5.66E-01 1.07E+00 Co-58
  • 5.49E-01 1.13E+00 Fe-59 * - 4.28E-01 2.24E+00 Co-60
  • 9.81 E-02 1.1OE+00 Zn-65 * - 6.30E-01 1.51 E+00 Nb-95 * - 1.21E-01 3.79E-01 Zr-95 * - 3.02E-01 1.74E+00 Cs-1 34
  • 8.65E-01 1.04E+00 Ba-140 * - 1.89E+00 5.25E+00 La-140 * - 9.86E-01 1.93E+00 Ra-226
  • 3.04E+00 1.74E+01 Th-228 * - 1.10E+00 1.28E+00 2/20/2002 Be-7
  • 3.26E+00 2.69E+01 K-40 * - 1.27E+01 3.26E+01 Mn-54
  • 1.28E+00 3.09E+00 Co-58
  • 1.92E-01 1.92E+00 Fe-59
  • 4.14E-01 1.22E+00 Zn-65 * - 8.90E-03 3.03E+00 Nb-95
  • 4.34E+00 2.74E+00 Zr-95
  • 1.84E+00 4.15E+00 Cs-1 34 * - 1.77E+00 2.88E+00 Cs-1 37 * - 6.32E-01 1.84E+00 Ba-140 * - 2.82E+00 1.40E+01 La-140
  • 2.41 E+01 2.13E+01 I Denotes a result less than the detection limit.

TABLE B-7.1 (cont.)

GAMMA SPECTROMETRY OF SANITARY WASTE TREATMENT WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 102B 3/20/2002 Be-7 * - 1.28E+00 1.13E+01 Monthly K-40

  • 5.94E+00 1.39E+01 Headworks Mn-54
  • 1.23E+00 1.20E+00 Co-58 * - 5.74E-01 1.09E+00 Fe-59
  • 2.62E-01 7.84E-01 Zn-65 * - 1.75E+00 1.64E+00 Nb-95
  • 4.13E-01 1.12E+00 Zr-95
  • 4.85E-01 1.97E+00 Cs-1 34
  • 4.78E-02 6.64E-01 Ba-140
  • 2.52E+00 5.96E+00 La-140 * - 4.36E-01 2.1 OE+00 Ra-226 * - 7.79E+01 2.01E+01 Th-228
  • 1.13E-01 8.41 E+00 4/17/2002 Be-7
  • 1.43E+01 2.57E+01 K-40 *- 2.28E+01 3.74E+01 Mn-54
  • 8.02E-01 2.89E+00 Co-58 *- 3.87E-01 3.1OE+00 Fe-59
  • 4.30E-01 2.90E+00 Zn-65 *- 1.11E+01 7.01 E+00 Nb-95 *- 1.80E+00 2.64E+00 Zr-95
  • 1.62E+00 4.59E+00 Cs-134
  • 8.96E-02 1.73E+00 Cs-1 37
  • 1.20E+00 2.79E+00 Ba-140 *- 1.49E-01 1.43E+01 La-140
  • 1.39E+00 2.70E+00

' Denotes a result less than the detection limit.

TABLE B-7.1 (cont.)

GAMMA SPECTROMETRY OF SANITARY WASTE TREATMENT WATER Results in pCUliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 102B 511512002 Be-7 * - 5.14E+00 1.35E+01 Monthly K-40 9.OOE+01 4.53E+01 Headworks Mn-54

  • 1.08E-01 1.54E+00 Co-58 * - 7.90E-02 1.59E+00 Fe-59
  • 9.79E-01 1.53E+00 Zn-65 * - 3.58E+00 3.91 E+00 Nb-95
  • 1.14E+00 1.57E+00 Zr-95
  • 6.05E-01 2.75E+00 Cs-134
  • 6.77E-01 1.78E+00 Cs-1 37 *- 1.65E+00 1.60E+00 Ba-140 * - 6.73E-01 7.68E+00 La-140
  • 1.29E+00 8.52E+00 611912002 Be-7 * - 3.80E-01 1.66E+01 K-40 * - 5.58E+00 2.13E+01 Mn-54
  • 8.79E-01 1.84E+00 Co-58
  • 2.66E+00 1.75E+00 Fe-59
  • 5.72E-01 1.13E+00 Zn-65 *- 1.45E+00 1.84E+00 Nb-95 *- 1.61E-01 1.68E+00 Zr-95
  • 1.87E+00 2.88E+00 Cs-1 34
  • 2.87E-01 1.77E+00 Ba-140
  • 5.23E-02 9.1 OE+00 La-140
  • 2.50E-01 1.93E+00
  • Denotes a result less than the detection limit.

TABLE B-7.1 (cont.)

GAMMA SPECTROMETRY OF SANITARY WASTE TREATMENT WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 102B 7/1712002 Be-7

  • 1.28E+01 2.14E+01 Monthly K-40
  • 2.73E+01 3.32E+01 Headworks Mn-54
  • 3.35E-01 2.46E+00 Co-58 * - 1.34E-01 2.46E+00 Fe-59 * - 9.21 E-01 2.28E+00 Co-60
  • 1.05E-01 2.31 E+00 Zn-65 * - 1.76E+00 2.78E+00 Nb-95
  • 6.85E-01 8.99E-01 Zr-95
  • 2.24E+00 3.76E+00 Cs-1 34
  • 3.93E-01 2.29E+00 Cs-1 37 * - 1.23E+00 2.32E+00 Ba-140
  • 4.53E+00 1.24E+01 La-140 * - 1.17E+00 4.35E+00 Ra-226
  • 1.36E+01 3.24E+01 Th-228 * - 8.74E-01 5.05E+00 8/11/2002 Be-7 * - 4.32E+00 1.18E+01 K-40
  • 6.94E-01 4.42E-01 Co-58 * - 1.96E+00 1.16E+00 Fe-59
  • 4.02E-01 1.12E+00 Zn-65 * - 3.17E-01 1.13E+00 Nb-95
  • 4.93E-01 1.16E+00 Zr-95 * - 1.58E-01 2.04E+00 Cs-1 34
  • 5.50E+00 1.23E+00 Cs-1 37
  • 7.66E-01 1.08E+00 Ba-140
  • 3.44E+00 9.73E+00 La-I 40 * - 1.20E+00 3.46E+00 Ra-226
  • 1.04E+01 1.51 E+01 Th-228 * - 1.1OE+00 1.93E+00

' Denotes a result less than the detection limit.

TABLE B-7.1 (cont.)

GAMMA SPECTROMETRY OF SANITARY WASTE TREATMENT WATER Results in pCUliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 102B 8/28/2002 Be-7 * - 5.23E+00 2.51 E+01 Monthly K-40 * - 1.74E+01 3.38E+01 Headworks Mn-54

  • 1.21 E-01 2.65E+00 Co-58
  • 9.57E-01 1.12E+00 Fe-59
  • 3.1 OE+00 2.33E+00 Zn-65 * - 1.45E+00 3.21 E+00 Nb-95
  • 4.49E-01 2.63E+00 Zr-95 * - 1.81E-01 4.41 E+00 Cs-1 34
  • 8.84E-01 1.81 E+00 Cs-I 37
  • 4.62E-01 2.45E+00 Ba-140
  • 3.62E+00 1.81 E+01 La-140
  • 4.83E+00 5.84E+00 9/3/2002 Be-7
  • 2.22E+00 8.77E+00 K-40
  • 1.79E+01 1.22E+01 Mn-54 * - 3.52E-01 8.40E-01 Co-58 * - 3.40E-01 9.43E-01 Fe-59 * - 2.39E-01 2.02E+00 Co-60
  • 3.61E-01 8.10E-01 Zn-65 * - 6.26E-01 1.04E+00 Nb-95 * - 7.06E-02 2.56E-01 Zr-95
  • 1.30E-01 1.45E+00 Cs-1 34
  • 2.OOE-02 8.04E-01 Ba-140 * - 8.45E-02 7.82E+00 La-140
  • 4.79E-01 2.51 E+00 Ra-226 * - 2.69E+00 1.42E+01 Th-228 * - 7.17E-01 2.02E+00
  • Denotes a result less than the detection limit.

TABLE B-7.1 (cont.)

GAMMA SPECTROMETRY OF SANITARY WASTE TREATMENT WATER Results inpCiliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 102B 10/1/2002 Be-7

  • 1.14E+01 2.55E+01 K-40 * - 2.50E+01 4.05E+01 Mn-54
  • 1.60E+00 2.74E+00 Co-58 * - 1.66E+00 3.OOE+00 Fe-59
  • 3.69E-01 2.81 E+00 Zn-65 * - 3.16E+00 4.74E+00 Nb-95 * - 2.29E+00 2.74E+00 Zr-95
  • 4.83E+00 4.54E+00 Cs-134
  • 1.79E+00 2.29E+00 Cs-1 37 * - 2.04E+00 2.69E+00 Ba-140
  • 1.66E+00 1.51E+01 La-140
  • 2.07E+01 3.99E+01 Th-228 * - 1.20E+00 5.51E+00 11/5/2002 Be-7
  • 4.24E-02 7.94E+00 K-40 * - 4.55E+00 1.80E+01 Mn-54 * - 9.29E-01 9.59E-01 Co-58
  • 3.30E-01 8.86E-01 Fe-59
  • 1.25E-01 8.19E-01 Zn-65 * - 3.07E+00 2.01 E+00 Nb-95
  • 1.19E-01 9.13E-01 Zr-95
  • 8.20E-02 1.51 E+00 Cs-1 34
  • 3.09E-02 8.48E-01 Cs-1 37 * - 1.39E-01 1.02E+00 Ba-140
  • 1.53E+00 5.92E+00 La-140 * - 3.OOE-02 1.87E+00 Ra-226 * - 4.43E+00 2.65E+01 Th-228
  • 4.22E+01 1.85E+01
  • Denotes a result less than the detection limit.

TABLE B-7.1 (cont.)

GAMMA SPECTROMETRY OF SANITARY WASTE TREATMENT WATER Results in pCi/liter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 102B 11/20/2002 Be-7

  • 1.82E+00 7.41 E+00 K-40 1.26E+02 2.53E+01 Mn-54
  • 1.08E-01 7.23E-01 Co-58
  • 5.47E-01 7.75E-01 Fe-59 * - 3.70E-01 1.87E+00 Co-60 * - 5.OOE-01 7.91E-01 Zn-65 * - 5.59E-01 1.56E+00 Nb-95
  • 4.26E-01 8.64E-01 Zr-95
  • 7.66E-01 1.33E+00 Cs-1 34 * - 3.52E-01 6.62E-01 Cs-1 37
  • 3.43E-01 7.74E-01 Ba-140 * - 2.98E+00 5.91 E+00 La-140 * - 7.41 E-01 1.73E+00 Ra-226
  • 1.57E+01 5.14E+01 Th-228 * - 4.57E+01 2.18E+01 12/3/2002 Be-7
  • 3.75E+00 1.46E+01 K-40
  • 1.50E+01 4.80E+01 Mn-54 *- 2.58E-01 1.58E+00 Co-58 *- 1.11E+00 1.73E+00 Fe-59
  • 1.72E+00 3.55E+00 Co-60 *- 6.61 E-01 1.68E+00 Zn-65 *- 4.33E+00 3.63E+00 Nb-95
  • 2.11E+00 1.74E+00 Zr-95
  • 7.84E-01 3.08E+00 Cs-1 34 *- 7.51E+00 2.05E+00 Cs-1 37
  • 2.97E-01 1.86E+00 Ba-140
  • 9.94E+00 7.85E+00 La-140 *- 1.56E+00 2.73E+00 Ra-226
  • 5.60E-01 3.21E+01
  • Denotes a result less than the detection limit.

TABLE B-7.1 (cont.)

GAMMA SPECTROMETRN '-OF SANITARY WASTE TREATMENT WATER Results in pCUliter COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 102C 1/16/2002 Be-7

  • 8.66E-01 1.31 E+00 Prior to K-40 9.14E+00 3.01 E+00 Discharge Mn-54
  • 1.69E-01 1.61 E-01 Co-58 *- 1.OOE-01 1.65E-01 Fe-59
  • 1.56E-02 3.68E-01 Co-60 * - 1.10E-03 1.83E-01 Zn-65
  • 8.27E-02 3.28E-01 Nb-95 * - 3.10E-02 1.45E-01 Zr-95
  • 6.71E-02 2.52E-01 Cs-1 34 * - 9.05E-02 1.39E-01 Cs-1 37
  • 2.58E-02 1.25E-01 Ba-140
  • 2.27E-01 7.04E-01 La-140
  • 3.87E+00 2.58E+00 Th-228 * - 3.77E-01 1.34E-01 102C 1/16/2002 Be-7 * - 1.74E+00 1.57E+01 Prior to K-40 6.04E+01 1.82E+01 Discharge Mn-54
  • 2.70E+00 1.60E+00 Co-58 * - 8.54E-01 1.71 E+00 Fe-59
  • 1.53E+00 3.31 E+00 Co-60 * - 6.23E-01 1.57E+00 Zn-65
  • 4.01 E-01 1.61 E+00 Nb-95
  • 1.24E+00 1.49E+00 Zr-95
  • 1.83E-01 2.73E+00 Cs-1 34
  • 1.59E+00 1.84E+00 Cs-1 37
  • 3.11E-01 1.63E+00 Ba-140
  • 2.44E+00 7.82E+00 La-I 40 * - 5.50E-03 2.58E+00 Ra-226 * - 2.44E+01 2.16E+01 Th-228
  • 6.47E+00 1.19E+01
  • Denotes a result less than the detection limit.

TABLE B-7.2 GAMMA SPECTROMETRY OF SANITARY WASTE TREATMENT WATER -

SUMMARY

Results in pCi/liter NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE 102A - FFTF Effluent Be-7 1.51E+O0 -1.OOE+01 1.46E+01 12 K-40 3.39E+01 -2.83E+01 1.35E+02 12 Mn-54 -2.14E-01 -1.91 E+OO 1.15E+O0 12 Co-58 -2.81 E-01 -1.04E+OO 8.65E-01 12 Fe-59 1.65E+00 -3.40E+O0 6.25E+00 12 Co-60 -1.21 E+03 -1.45E+04 1.90E-01 12 Zn-65 -1.65E+00 -5.69E+00 1.59E-01 12 Nb-95 8.73E-01 -1.1 OE+O0 4.41 E+00 12 Zr-95 -1.46E-01 -1.93E+00 3.37E+O0 12 Cs-1 34 6.41 E-01 -3.92E+00 5.90E+00 12 Cs-137 -9.15E+02 -1.1OE+04 2.47E+00 12 Ba-140 -4.24E+00 -1.85E+01 5.09E+00 12 La-140 2.40E-01 -3.35E+00 4.52E+00 12 Ra-226 -6.91 E+00 -8.45E+01 2.99E+01 12 Th-228 -3.52E+00 -1.06E+02 2.96E+01 12 (I) Indicator Station

TABLE B-7.2 (cont.)

GAMMA SPECTROMETRY OF SANITARY WASTE TREATMENT WATER -

SUMMARY

Results in pCilliter NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE 102B - Monthly Headworks Be-7 (I) 1.94E+00 -6.11E+00 1.43E+01 14 0 K-40 (I) 1.51E+01 -2.50E+01 1.26E+02 14 2 Mn-54 (I) 4.42E-01 -9.29E-01 1.60E+00 14 0 Co-58 (I) -7.21E-02 -1.96E+00 2.66E+00 14 0 Fe-59 (I) 1.55E+00 -9.21E-01 6.28E+00 14 0 Co-60 (I) 4.33E-01 -6.61E-01 3.1OE+00 14 0 Zn-65 (I) -2.41E+00 -1.11E+01 -8.90E-03 14 0 Nb-95 (I) 4.09E-01 -2.29E+00 4.34E+00 14 0 Zr-95 (I) 1.04E+00 -3.02E-01 4.83E+00 14 0 Cs-134 (I) 1.33E-01 -7.51E+00 5.50E+00 14 0 Cs-137 (I) -1.OOE-01 -2.04E+00 1.20E+00 14 0 Ba-140 (I) 1.34E+00 -2.98E+00 9.94E+00 14 0 La-140 (I) 1.80E-01 -1.56E+00 3.02E+00 14 0 Ra-226 (I) 8.10E+00 -7.79E+01 5.62E+01 14 0 Th-228 (I) 1.72E+00 -4.57E+01 4.22E+01 14 0 (I) Indicator Station

TABLE B-7.2 (cont.)

GAMMA SPECTROMETRY OF SANITARY WASTE TREATMENT WATER -

SUMMARY

Results in pCVliter NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE 102C - Prior to Discharge Be-7 (I) -4.37E-01 -1.74E+00 8.66E-01 2 0 K-40 (I) 3.48E+01 9.14E+00 6.04E+01 Mn-54 (I) 1.43E+00 1.69E-01 2.70E+00 Co-58 (I) -4.77E-01 -8.54E-01 -1.OOE-01 Fe-59 (I) 7.73E-01 1.56E-02 1.53E+00 Co-60 (I) -3.12E-01 -6.23E-01 -1.1OE-03 Zn-65 (I) 2.42E-01 8.27E-02 4.01 E-01 Nb-95 (I) 6.05E-01 -3.10E-02 1.24E+00 Zr-95 (I) 1.25E-01 6.71 E-02 1.83E-01 Cs-1 34 (I) 7.50E-01 -9.05E-02 1.59E+00 Cs-1 37 (I) 1.68E-01 2.58E-02 3.11E-01 Ba-140 (I) 1.33E+00 2.27E-01 2.44E+00 La-140 (I) 5.63E-02 -5.50E-03 1.18E-01 Ra-226 (I) -1.03E+01 -2.44E+01 3.87E+00 Th-228 (I) 3.05E+00 -3.77E-01 6.47E+00 (I) Indicator Station

TABLE B-8.1 TRITIUM IN SANITARY WASTE TREATMENT WATER Results in pCUliter COLLECTION OVERALL LOCATION PERIOD RESULT UNCERTAINTY FFTF - Effluent H-3 1/2/2002 - 2/5/2002 2.90E+03 1.OOE+02 102A 2/5/2002 - 3/5/2002 2.85E+03 1.40E+02 3/512002 - 4/2/2002 2.48E+03 1.30E+02 4/2/2002 - 517/2002 2.98E+03 1.40E+02 5/7/2002 - 6/412002 2.97E+03 1.50E+02 6/4/2002 - 7/2/2002 3.08E+03 1.53E+02 7/2/2002 - 8/6/2002 3.76E+03 1.65E+02 8/6/2002 - 9/4/2002 4.71E+03 1.78E+02 9/3/2002 - 10/1/2002 3.66E+03 1.67E+02 10/1/2002 - 11/5/2002 3.16E+03 2.14E+02 11/5/2002 - 12/3/2002 3.30E+03 3.35E+02 12/3/2002 - 1/2/2003 3.52E+03 2.18E+02 Monthly Headworks H-3 1/16/2002 8.00E+02 7.00E+01 102B 2/20/2002 9.90E+02 1.OOE+02 3/20/2002 4.14E+02 7.70E+01 4/17/2002 1.41 E+03 1.1OE+02 5/15/2002 1.45E+03 1.10E+02 6/19/2002 9.88E+02 1.02E+02 7/17/2002 1.02E+03 1.04E+02 8/1/2002 1.19E+03 1.16E+02 8/28/2002 1.05E+03 1.09E+02 9/3/2002 1.21 E+03 1.21 E+02 10/1/2002 6.81E+02 1.54E+02 11/5/2002 9.91 E+02 2.53E+02 11/20/2002 9.37E+02 2.35E+02 12/3/2002 1.08E+03 1.67E+02 Prior to Discharge H-3 1/16/2002 5.40E+02 6.OOE+01 102C 1/16/2002 6.30E+02 8.OOE+01

TABLE B-8.2 TRITIUM IN SANITARY WASTE TREATMENT WATER -

SUMMARY

Results in pCi/liter NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE All Samples H-3 (I) 1.96E+03 4.14E+02 4.71E+03 28 28 FFTF Effluent H-3 (I) 3.28E+03 2.48E+03 4.71 E+03 12 12 102A Monthly Headworks H-3 (I) 1.02E+03 4.14E+02 1.45E+03 14 14 102B Prior to Discharge H-3 (I) 5.85E+02 5.40E+02 6.30E+02 2 2 102C (I) Indicator Stations

TABLE B-9.1 GAMMA SPECTROMETRY OF SANITARY WASTE TREATMENT SEDIMENT Results in pCi/kilogram COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 102D 10/30/2002 Be-7

  • 1.95E+02 1.50E+02 K-40 9.88E+03 4.82E+02 Mn-54 * - 9.76E+00 1.41 E+01 Co-58 * - 1.96E+01 1.59E+01 Fe-59 * - 2.18E+01 3.76E+01 Co-60 2.77E+02 2.29E+01 Zn-65
  • 6.26E+00 3.76E+01 Nb-95
  • 3.86E+01 2.04E+01 Zr-95
  • 2.01 E+01 2.95E+01 Cs-1 34
  • 6.26E+00 1.40E+01 Cs-1 37 1.23E+02 2.74E+01 Ba-140
  • 9.54E+00 1.87E+02 La-1 40 * - 8.82E+01 5.63E+01 Ra-226 5.32E+02 3.76E+01 Th-228 1.83E+03 4.71 E+02
  • Denotes a result less than the detection limit.

TABLE B-9.2 GAMMA SPECTROMETRY OF SANITARY WASTE TREATMENT WATER -

SUMMARY

Results in pCVliter NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE 102D Be-7 (I) 1.95E+02 1.95E+02 1.95E+02 1 0 K-40 (I) 9.88E+03 9.88E+03 9.88E+03 1 Mn-54 (I) -9.76E+00 -9.76E+00 -9.76E+00 I Co-58 (I) -1.96E+01 -1.96E+01 -1.96E+01 I Fe-59 (I) -2.18E+01 -2.18E+01 -2.18E+01 I Co-60 (I) 2.77E+02 2.77E+02 2.77E+02 1 Zn-65 (I) 6.26E+00 6.26E+00 6.26E+00 1 Nb-95 (I) 3.86E+01 3.86E+01 3.86E+01 1 Zr-95 (I) 2.01 E+01 2.01 E+01 2.01 E+01 1 Cs-1 34 (I) 6.26E+00 6.26E+00 6.26E+00 1 Cs-137 (I) 1.23E+02 1.23E+02 1.23E+02 I Ba-140 (I) 9.54E+00 9.54E+00 9.54E+00 I La-140 (I) -8.82E+01 -8.82E+01 -8.82E+01 1 Ra-226 (I) 5.32E+02 5.32E+02 5.32E+02 I Th-228 (I) 1.83E+03 1.83E+03 1.83E+03 I (I) Indicator Stations

TABLE B-10.1 GAMMA SPECTROMETRY OF COOLING TOWER SEDIMENT Results in pCikilogram COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 119B 8/23/2002 Be-7 6.43E+03 5.18E+02 K-40 1.03E+04 9.20E+02 Mn-54

  • 2.19E+01 3.86E+01 Co-58
  • 5.62E-01 3.79E+01 Fe-59 * - 1.07E+01 7.69E+01 Co-60
  • 3.94E+00 1.92E+01 Zn-65 * - 2.48E+01 4.94E+01 Nb-95
  • 6.69E+00 1.68E+01 Zr-95
  • 2.97E+01 5.76E+01 Cs-134
  • 1.24E+01 2.72E+01 Cs-137 1.63E+02 3.13E+01 Ba-140
  • 1.42E+02 2.19E+02 La-140
  • 6.83E+00 7.90E+01 Ra-226 3.30E+03 5.04E+02 Th-228 8.52E+02 1.12E+02
  • Denotes a result less than the detection limit.

TABLE B-10.2 GAMMA SPECTROMETRY OF COOLING TOWER SEDIMENT -

SUMMARY

Results in pCiVkilogram NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE 119B Be-7 (I) 6.43E+03 6.43E+03 6.43E+03 1 1 K-40 (I) 1.03E+04 1.03E+04 1.03E+04 1 1 Mn-54 (I) 2.19E+01 2.19E+01 2.19E+01 1 0 Co-58 (I) 5.62E-01 5.62E-01 5.62E-01 1 0 Fe-59 (I) -1.07E+01 -1.07E+01 -1.07E+01 1 0 Co-60 (I) 3.94E+00 3.94E+00 3.94E+00 1 0 Zn-65 (I) -2.48E+01 -2.48E+01 -2.48E+01 1 0 Nb-95 (I) 6.69E+00 6.69E+00 6.69E+00 1 0 Zr-95 (I) 2.97E+01 2.97E+01 2.97E+01 1 0 Cs-134 (I) 1.24E+01 1.24E+01 1.24E+01 1 0 Cs-137 (I) 1.63E+02 1.63E+02 1.63E+02 1 1 Ba-140 (I) 1.42E+02 1.42E+02 1.42E+02 1 0 La-140 (I) 6.83E+00 6.83E+00 6.83E+00 1 0 Ra-226 (I) 3.30E+03 3.30E+03 3.30E+03 1 1 Th-228 (I) 8.52E+02 8.52E+02 8.52E+02 I 1 (I) Indicator Stations

TABLE B-11.2 GAMMA SPECTROMETRY OF SPRAY POND DRAIN FIELD SEDIMENT -

SUMMARY

Results in pCi/kilogram NUMBER NUMBER NUCLIDE AVERAGE LOW HIGH SAMPLES POSITIVE 120 Be-7 (I) -1.22E+01 -1.22E+01 -1.22E+01 K-40 (I) 1.49E+04 1.49E+04 1.49E+04 Mn-54 (I) 2.07E+01 2.07E+01 2.07E+01 Co-58 (I) -7.07E+00 -7.07E+00 -7.07E+00 Fe-59 (I) -1.72E+01 -1.72E+01 -1.72E+01 Co-60 (I) 1.36E+02 1.36E+02 1.36E+02 Zn-65 (I) -2.26E+01 -2.26E+01 -2.26E+01 Nb-95 (I) 5.43E+00 5.43E+00 5.43E+00 Zr-95 (I) 3.13E+01 3.13E+01 3.13E+01 Cs-1 34 (I) -2.39E+00 -2.39E+00 -2.39E+00 Cs-1 37 (I) 1.39E+01 1.39E+01 1.39E+01 Ba-140 (I) -1.38E+00 -1.38E+00 -1.38E+00 La-1 40 (I) 2.67E+00 2.67E+00 2.67E+00 Ra-226 (I) 1.25E+03 1.25E+03 1.25E+03 Th-228 (I) 6.48E+02 6.48E+02 6.48E+02 (I) Indicator Station

TABLE B-11.1 GAMMA SPECTROMETRY OF SPRAY POND DRAIN FIELD SEDIMENT Results in pCi/kilogram COLLECTION OVERALL LOCATION PERIOD NUCLIDE RESULT UNCERTAINTY 120 4/30/2002 Be-7 * - 1.22E+01 1.12E+02 K-40 1.49E+04 5.70E+02 Mn-54

  • 2.07E+01 1.48E+01 Co-58 * - 7.07E+00 1.36E+01 Fe-59 * - 1.72E+01 2.88E+01 Co-60 1.36E+02 9.40E+00 Zn-65 * - 2.26E+01 2.45E+01 Nb-95
  • 5.43E+00 3.90E+00 Zr-95
  • 3.13E+01 2.17E+01 Cs-1 34 * - 2.39E+00 8.37E+00 Cs-1 37
  • 1.39E+01 7.48E+00 Ba-140 * - 1.38E+00 6.67E+01 La-140
  • 2.67E+00 1.21 E+01 Ra-226 1.25E+03 1.79E+02 Th-228 6.48E+02 2.16E+01
  • Denotes a result less than the detection limit.