ML101400135

From kanterella
Jump to navigation Jump to search
Staiton 2009 Annual Radiological Environmental Operating Report
ML101400135
Person / Time
Site: Columbia  
Issue date: 05/12/2010
From: Oxenford W
Energy Northwest
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards
References
G02-10-073
Download: ML101400135 (161)


Text

{{#Wiki_filter:ENERGY NORTHWEST W. Scott Oxenford Columbia Generating Station P.O. Box 968, PE08 Richland, WA 99352-0968 Ph. 509.377.4300 1 F. 509.377.4150 soxenford @ energy-northwest.com May 12, 2010 G02-10-073 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Energy Facility Site Evaluation Council ATTN: EFSEC Manager P.O. Box 43172 Olympia, WA 98504-3172

Subject:

COLUMBIA GENERATING STATION, DOCKET NO. 50-397 INDEPENDENT SPENT FUEL STORAGE INSTALLATION, DOCKET NO. 72-35 2009 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT

References:

1. 2. 3. Columbia Generating Station Technical Specification 5.6.1 Independent Spent Fuel Storage Installation Technical Specification 5.4.b EFSEC Resolution No. 260, January 13, 1992

Dear Sir or Madam:

In accordance with the requirements of References 1-3, the subject report is submitted as an enclosure to this letter. If you have questions regarding this information, please contact TE Northstrom at (509) 377-8462. Respectfully, W.S. Vice Nuclear Generation & Chief Nuclear Officer Enclosure cc: D. McBaugh (WDOH) L. Albin (WDOH) J.M. Ayres (WDOE) L. Vigue (WDFW) R.L. Dirkes (PNNL) R.N. Sherman (BPA/1399) NRC Region IV Administrator NRC NRR Project Manager NRC Sr. Resident Inspector (988C) Director, SFPO-NRC NMSS W.A. Horin (Winston & Strawn) t~XIAS5z~

m COLUMBIA GENERATING STATION 2009 ANNUAL RADIOLOGICAL .... ENVIRONMENTAL OPERATING. REPORT RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM FOR THE COLUMBIA GENERATING STATION U ENERGY NORTHWEST

ENERGY NORTHWEST People Vision Solutions COLUMBIA GENERATING STATION RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM 2009 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT For Calendar Year 2009 Preparation Date: April 2010 Submitted Date: May 2010 Authored By : _./ m'*--- David Mee, ENW Environmental Services Reviewed By: .1'I/, i Elisa Nguyen, ENWI virdtiniental Services Approved By: Z,,. / '1 '/ '- Terry Northstror-n ENW Environmental Services Supervisor

TABLE OF CONTENTS SECTION PAGE 1.0 EXECUTIVE

SUMMARY

1-1 2.0 DEFINITIONS 2-1

3.0 INTRODUCTION

3-1 3.1 Site Description 3-1 3.2 Program Background 3-1 3.3 Program Objectives 3:2 4.0 PROGRAM DESCRIPTION 4-1 4.1 Sample Locations 4-1 4.2 Independent Spent Fuel Storage Installation 4-1 4.3 Land Use Census 4-2 4.4 Sampling Methods 4-2 4.4.1 Direct Radiation 4-2 4.4.2 Airborne - Particulate/Iodine 4-2 4.4.3 Water 4-3 4.4.4 Soil 4-4 4.4.5 Sediment 4-4 4.4.6 Fish 4-4 4.4.7 Milk 4-5 4.4.8 Garden Produce 4-5 4.5 Sample Analyses 4-5 4.5.1 Analysis of TLDs 4-5 4.5.2 Gross Beta Activity on Air Particulate Filters 4-6 4.5.3 Measurement of Gamma Emitting Radionuclides 4-6 4.5.4 Gross Alpha and Gross Beta Activity in Water 4-7 4.5.5 Tritium in Water 4-7 4.5.6 Sr-90, Fe-55, and Ni-63 in Water 4-7 4.5.7 Low Level Iodine-131 in Milk and Water 4-7 ý009 Annual Radiological Environmental Operating Report i Energy Northwest/Columbia Generating Station

-.3 TABLE OF CONTENTS SECTION PAGE 4.6 Data Analysis Methods 4-7 U 4.7 Changes to the Sampling Program in 2009 4-8 5.0, RESULTS AND DISCUSSION 5-1 5.1 Direct Radiation 5-1 I 5.2 Airborne Particulate/Iodine 5-3 5.3 Water 5-5 5.3.1 Surface Water 5-5 5.3.2 Ground Water 5-6 5.4 Soil 5-7 I 5.5 River Sediment 5-7 5.6 Fish 5-7 5.7 Milk 5-8 5.8 Garden Produce 5-8 5.9 Special Interest Stations 5-8 I 5.9.1 Storm Drain Pond (Station 101) 5-8 5.9.2 Sanitary Waste Treatment Facility (Station 102) 5-9 5.9.3 Cooling Tower Sediment Disposal Area (Station 119) 5-9 5.9.4 Spray Pond Drain Field (Station 120) 5-10 5.9.5 Independent Spent Fuel Storage Installation 5-10 5.9.6 Additional Air Sample and TLD Locations 5-11 5.10 2009 Sample Deviations 5-12 I I 2009 Annual Radiological Environmental Operating Report ii Energy Northwest/Cqlumbia Generating Station

TABLE OF CONTENTS SECTION PAGE 6.0 QUALITY ASSURANCE AND QUALITY CONTROL 6-1 6.1 Quality Control for the Energy Northwest Environmental TLD Program 6-1 6.2 Quality Control for the Environmental Sample Program 6-1 6.2.1 Sample Collection Quality Control 6-2 6.2.2 Laboratory Instruments Quality Control 6-2 6.2.3 Sample Batch Quality Control 6-2 6.3 Laboratory Intercomparison Program Participation and Results 6-3

7.0 REFERENCES

7-1 8.0 ERRATA 8-1 APPENDIX A. Data Tables A and B 2009 Annual Radiological Environmental Operating Report iii Energy Northwest/Columbia Generating Station

LIST OF TABLES I TABLE PAGE 4-1 Radiological Environmental Monitoring Program Sampling Plan 4-9 4-2 REMP Sample Stations and Requirements 4-11 4-3 2009 Five MileLand Use Census Results 4-15 4-4 Comparison of Laboratory Nominal Lower Limits of Detection With U Offsite Dose Calculation Manual Requirements 4-16 5-1 REMP Sample Deviations for 2009 5-12 I 5-2 REMP Summary 5-13 5-3 Quarterly TLD Data Summary with Comparison to Preoperational and Operational Periods 5-23 5-4 Annual TLD Data Summarywith Comparison to the Preoperational and Operational Periods 5-25 6-1 2009 Environmental Spiked Dosimeter Results 6-4 6-2 ENW REMP Program Cross Check Performance Results 6-5 I I I I I I 2009 Annual Radiological Environmental Operating Report iv Energy Northwest/Columbia Generating Station

LIST OF FIGURES FIGURE PAGE 4-1 Select REMP Sampling Locations Within 0.8 Miles of CGS 4-17 4-2 Select REMP Sampling Locations Between 0.8 and 2.8 Miles 4-18 4-3 Select REMP Sampling Locations Beyond 2.8 Miles 4-19 4-4 ISFSI TLD Stations Layout 4-20 5-1 Site Boundary Quarterly TLDs 1984-2008 Hi/Low/Mean and 2009 Mean by Sector 5-1 5-2 Near Plant Stations Quarterly TLDs 1984-2008 Hi/Low/Mean and 2009 Mean by Sector 5-2 5-3 Remote Quarterly TLDs 1984-2008 Hi/Low/Mean and 2009 Mean by Sector 5-2 5-4 1985-2008 Weekly Hi/Low/Mean and 2009 Weekly Mean Gross Beta in Air-Near Plant Stations 5-3 5-5 1985-2008 Weekly Hi/Low/Mean and 2009 Weekly Mean Gross Beta in Air-Remote Stations 5-4 5-6 Gross Beta in River/Drinking and Plant Discharge Water for 2009 5-5 5-7 Tritium in River/Drinking and Plant Discharge Water for 2009 5-6 5-8 Cooling Tower Sediment Activity Levels for Disposals made in 2009 5-10 5-9 ISFSI TLD trend at CGS 5-11 2009 Annual Radiological Environmental Operating Report V Energy Northwest/Columbia Generating Station

I I I I II I I I i

1.0 EXECUTIVE

SUMMARY

The purpose of the Energy Northwest Radiological Environmental Monitoring Program (REMP) is to evaluate the radiological impact that Columbia Generating Station (CGS) operation may have on the environment. Sampling is performed as specified in the Offsite Dose Calculation Manual (ODCM) and agreements made with the State of Washington Energy Facility Site Evaluation Council (EFSEC). Additional sampling is also performed to meet Nuclear Energy Institute (NED guidelines or an Energy Northwest initiative. Sampling and analysis is performed by the Energy Northwest Environmental Services group with analysis performed at the Applied Process Engineering Laboratory (APEL) facility located in Richland, Washington. Direct radiation services are provided by Pacific Northwest National Laboratory (PNNL). Specialized analyses may be contracted to other outside vendors as needed. A variety of environmental samples are routinely collected and analyzed by the REMP. Most samples are collected from locations that could potentially be affected by CGS operation. Some samples are also collected as controls from areas that could not reasonably be affected by CGS operation. The types of samples collected include air, water, soil, sediment, milk, fish, and garden produce. Additionally, the program monitors direct radiation at 79 different locations. Analysis results are trended and compared to results from control locations, results obtained in previous operational and pre-operational periods, and regulatory limits. The results contained in this report indicate that CGS operation had no significant radiological impact on the environment during 2009. The sample results are consistent with the results obtained from control locations, results from the preoperational period, and historical results collected since CGS began commercial operation. No unusual finding or adverse trends were observed. Most radioactive material identified in this report is of natural origin or known to be present in the environment around CGS in the quantities identified. Below is a summary of the 2009 results by exposure pathway: Direct Radiation - No impact was identified at locations beyond the CGS controlled area. Within the controlled area, the only impact identified was at locations known to be influenced by the Independent Spent Fuel Storage Installation (ISFSI) or radiation from the turbine building during operation. Airborne-No impact was identified. Waterborne-For surface/drinking water locations, the only impact identified was low level tritium in storm drain water attributed to recapture of CGS effluent tritium. Tritium identified in sanitary waste water is attributed to discharges made from facilities operated by the Department of Energy. For ground water, tritium activity identified is at levels consistent with levels known to exist in Hanford groundwater. Radionuclide activity identified in river sediment is consistent with activity levels known to exist in Hanford area sediment and soils. Ingestion-No impact was identified in any of the food sample results. 2009 Annual Radiological Environmental Operating Report 1-1 Energy Northwest/Columbia Generating Station 2009 Annual Radiological Environmental Operating Report 1-1 Energy Northwest/Columbia Generating Station

2.0 DEFINITIONS

2.0 DEFINITIONS Airborne Activity Sampling: Continuous sampling of air through the collection of particulates and radionuclides on filter media. Periodic soil samples are collected for gamma isotopic analysis to provide ' information on deposition to the soil from airborne releases. Alpha Particle (a): A charged particle emitted from the-nucleus of an atom having a mass and charge equal in magnitude of a helium nucleus. Becquerel (Bq): One disintegration per second. One picocurie (pCi) equals 0.037 becquerel. Beta Particle ([3): Charged particle emitted from the nucleus of an atom with a mass and charge equal in magnitude to that of an electron. Blank Sample: A sample of the same media as the field sample being analyzed but without any radionuclide(s) being measured. It enables correction for the inherent sample background. CGS: Columbia Generating Station, formerly referred to as WNP-2. CGS Controlled Area: The area within a 1.2 mile radius of the CGS reactor building and a narrow corridor extending from CGS east to the Columbia River. Composite Sample: A series of single collected portions (aliquots) analyzed as one sample. The aliquots making up the sample are collected at time intervals that are very short compared to the composite period. Control Station: A sampling station in a location not likely to be affected by plant effluents due to its distance and/or direction from the Columbia Generating Station. Counting Error: An estimate of the two-sigma uncertainty associated with the sample results based on respective count times. + / -2,f(SampleCPM / CountTime + BkgCpm / CountTime) Curie (Ci): A measure of radioactivity; equal to 3.7 x 1010 disintegrations per second, or 2.22 x 1012 disintegrations per minute. Direct Radiation Monitoring: The measurement of radiation dose at various distances from the plant is assessed using thermoluminescent dosimeters and pressurized ionization chambers. DOE: U.S. Department of Energy. DOH: Washington State Department of Health. EFSEC: Energy Facility Site Evaluation Council. FFTF: Fast Flux Test Facility. Flow Proportional Sampling: Sample collection volume or frequency determined as a function of the flow rate of the water being sampled. Grab Sample: A single discrete sample drawn at one point in time. IDC: Energy Northwest Industrial Development Complex, formerly referred to as the WNP-I and WNP-4 sites. Indicator Station: A sampling location that is likely to be affected by plant effluents due to its proximity and/or direction from the Columbia Generating Station. Ingestion Pathway Monitoring: The ingestion pathway includes milk, soil, fish, and garden produce. Also sampled (under special circumstances) are other media such as vegetation and animal products such as eggs and meat when additional information about particular radionuclides is needed. ISFSI: Independent Spent Fuel Storage Installation. Lower Limit of Detection (LLD): The smallest concentration of radioactive material in a sample that will yield a net count (above system background) that will be detected with 95% probability with a 5% probability of a false conclusion that a blank observation represents "real" signal. MAPEP: Mixed Analyte PerformanceEvaluation Program. Mean: The average, i.e., the sum of results divided by the number of results. Microcurie: 3.7 x 104 disintegrations per second, or 2.22 xl0 6 disintegrations per minute. 2009 Annual Radiological Environmental Operating Report 2-1 Energy North west/Columbi a Generating Station

SI Milliroentgen (mR): 1/1000 Roentgen; a unit of exposure to X or gamma radiation. MDA: Minimum Detectable Activity. MDC: Minimum Detectable Concentration. NEI: Nuclear Energy Institute NIST: National Institute of Standards and Technology. NPDES: National Pollutant Discharge Elimination System. NRC: U.S. Nuclear Regulatory Commission. ODCM: Offsite Dose Calculation Manual. Licensing document that contains the offsite radiological requirements. Picocurie (pCi): I x 1012 Curie or 2.22 disintegrations per minute; one millionth of a microcurie. REMP: Radiological Environmental Monitoring Program. Range: The difference between the smallest and largest results. Restricted Area: Any area to which access is controlled for purposes of protection of individuals from exposure to radiation and radioactive materials. Roentgen: Unit of exposure to ionizing radiation in air. Site Certification Agreement (SCA): The initial Columbia Generating Station licensing agreement with the State of Washington. The REMP sampling commitments in the SCA have been modified by EFSEC agreements. Spiked Sample: A sample that has had a known quantity of radionuclide(s) added for the purposes of assessing analytical performance. Standard Deviation: A measure of the scatter of a set of observations (or samples) around their mean value. Indicated by "a". Standard Error of the Mean: An estimate of the uncertainty associated with the mean of observation (or sample) averages. Also known as the standard deviation. SE = SS_ n where S2, the variance is (n2 = )I y (Xi -_X)2 m (n-I1) SWTF: Sanitary Waste Treatment Facility. The sanitary waste processing facility for the Columbia Generating Station, the IDC, and the Department of Energy's 400 Area. TEDA: triethylene diamine Thermoluminescent Dosimeter (TLD): A TLD is a phosphor that stores energy from exposure to radiation and emits that energy in the form of light when heated. I I I Ia I I S V VI S S U I I 2009 Annual Radiological Environmental Operating Report 2-2 Energy Northwest/Columbia Generating Station

Ii V i

  • i:

3.0 INTRODUCTION

I I I S .3 U

3.0 - INTRODUCTION 3.1 Site Description The Columbia Generating Station is a 1200 MWe commercial nuclear power plant that achieved initial criticality on January 19, 1984. The plant is located in a sparsely populated shrub-steppe region within the Department of Energy (DOE) Hanford Site in southeastern Washington. The plant is approximately three miles west of the Columbia River and is surrounded on all sides by uninhabited desert land. The nearest large population centers are Richland, Pasco and Kennewick, which are 12 miles south, 18 miles southeast, and 21 miles southeast, respectively. The nearest privately owned lands are located approximately four miles east-northeast of the plant, across the Columbia River. The site has a bimodal wind pattern with winds primarily from the northwest and south.!1 7) The primary region of focus for REMP sampling is the farming region east of the plant. Naturally occurring radionuclides exist in detectable quantities throughout the world and are seen in many of the samples collected for the REMP. Some examples of naturally occurring radionuclides that are frequently seen in samples are K-40, Be-7, Ac-228 (present as a decay product of Ra-228), and Ra-226. Additionally, some relatively long lived anthropogenic radioisotopes, such as Sr-90 and Cs-137, are also seen in some REMP samples; these radionuclides exist in measurable quantities throughout the world as a result of fallout from atmospheric nuclear weapons testing. Due to the location of CGS on the Hanford Site, there are other sources of reactor produced radionuclides in close proximity to the plant. CGS is unique in the U.S. commercial nuclear power industry in this respect. Hanford related radionuclides, most notably tritium, are identified in some CGS REMP samples. Though the presence of these radionuclides in the vicinity of CGS are not necessarily reflective of CGS activity, changes in the levels of these radionuclides are monitored to assess any contribution that CGS may be making to the established background. The DOE has an active REMP program for the Hanford Site that overlaps the CGS REMP. 3.2 Program Background The CGS REMP is designed to conform to the Nuclear Regulatory Commission (NRC) Regulatory Guides 4.1,(') 4.8,'(2) and the Radiological Assessment Branch Technical Position.3 ) In addition, the REMP also meets the requirements of 10 CFR 72.44(d)(2) for coverage of the ISFSI. The quality assurance aspects of the sampling program and the thermoluminescent dosimetry are conducted in accordance with Regulatory Guides 4.15(4) and 4.13.(5) The REMP also adheres to the requirements of the Washington Energy Facility Site Evaluation Council (EFSEC),(6" the Columbia Generating Station Technical Specifications(7) and the Offsite Dose Calculation Manual (ODCM).(8 ) These requirements cover the environmental sampling and sample analysis aspects of the program, and also the reporting and quality assurance requirements. The preoperational phase of the program, which lasted from March 1978 until initial criticality in January 1984, provided a baseline of background environmental data. Variability in the background levels of radioactivity over time is due to differences in geologic composition, meteorological 2009 Annual Radiological Environmental Operating Report 3-1 Energy Northwest/Columbia Generating Station

I conditions, decay of nuclear testing fallout material in the environment, and seasonal changes. Variability in results may also have been introduced by changing analytical contractors and the use of different correction factors over the years. The Energy Northwest Environmental Services Laboratory performed most REMP sample analyses in 2009. The Pacific Northwest National Laboratory processed the thermoluminescent dosimeters used for the REMP in 2009. In addition to evaluating the environmental concentrations against regulatory limits, the REMP may also compare results to state standards.* 12, 13) The results may also be evaluated by comparing them to similar measurements made during the preoperational and previous operational periods and to the detection capabilities associated with the current methods of analysis. 3.3 Program Objectives The REMP provides an independent mechanism for determining the levels of radioactivity in the plant environs to ensure that any accumulation of radionuclides in the environment will not become significant as a result of station operations or exceed established limits. While in-plant monitoring programs are used to ensure that 10 CFR 20(9) and 10 CFR 50(10) criteria for releases of radioactive effluents are met, the REMP provides direct verification of any environmental impact that may result from plant effluents. N I I a I I I I U 2009 Annual Radiological Environmental Operating Report 3-2 Energy Northwest/Columbia Generating Station I1

4.0 PROGRAM DESCRIPTION

4.0 PROGRAM DESCRIPTION The ODCM contains the CGS licensing based sampling requirements for the REMP. Additional sampling requirements are specified in resolutions with the Washington State Energy Facility Site Evaluation Council (EFSEC) or are self initiated in response to site specific or industry wide concerns. The sampling plan presented in Table 4-1 gives an overview of the REMP sampling routine, a summary of the sample locations, the specified collection frequency, and the types of analyses to be performed. The methods of sampling and sampling frequencies utilized in the program are mostly dictated by regulatory requirements. Factors such as nuclide half-lives and the major exposure pathways for the radionuclides potentially released from the plant have been taken into account in' determining the sampling methodology. 4.1 Sample Locations One hundred and thirteen sampling locations (referred to as 'stations') are included in the monitoring program. More than one sample type may be collected at a sample station. One hundred and four indicator and three control stations are located within a 10-mile radius of CGS. Six additional stations are located beyond the ten mile radius of the plant, two are indicator locations and 4 are control locations. Sample stations are listed in Tables 4-1 and 4-2. Most station locations are shown in Figures 4-1 to 4-4. The locations of most sample stations have been selected on the basis of an exposure pathway analysis. The exposure pathway analysis was based on factors such as weather patterns, anticipated emissions, likely receptors, and land use in the surrounding areas. Samples collected from stations located in areas that potentially could be influenced by CGS operation are used as indicators. Samples collected from locations that are not likely to be influenced by CGS operation serve as controls. Results from indicator stations are compared to the results from control stations and results obtained during the previous operational and preoperational years of the program in order to assess the impact CGS operation may be having on the environment. 4.2 Independent Spent Fuel Storage Installation (ISFSI) The Independent Spent Fuel Storage Installation (ISFSI) is a fenced, secured area constructed to provide a storage location for spent nuclear fuel. The spent fuel is stored in HI-STORM dry storage casks which are placed on concrete pads inside the facility. The pads are 30-feet wide by 135-feet long and each pad can hold up to 18 casks. The ISFSI is located approximately 500 meters north-northwest of the reactor building. REMP monitoring of the ISFSI is performed using quarterly and annual TLDs placed at 10 different locations on the outer security fence of the facility. In addition, two other TLD stations, Station 121 located approximately 200 meters north of the turbine building and Station 122 located approximately 100 meters north of the ISFSI, were installed to monitor ISFSI direct radiation. Figure 4-1 shows the ISFSI location in relation to CGS and the position of the 2 additional TLD locations. Figure 4-4 shows the location of the 10 TLD stations located around the ISFSI. This arrangement of TLDs in conjunction with the radiological surveys conducted by the CGS Radiation Protection Department serve as the radiological monitoring program for the ISFSI. 2009 Annual Radiological Environmental Operating Report 4-1 Energy North west/Columbi a Generating Station

I U 4.3 Land Use Census A land use census for areas within five miles of CGS is performed annually. The objective of the land m use census is to identify the locations of the nearest milk animal, residence, and garden greater than 500 ft2 producing broadleaf vegetation. This information is used to determine whether any site located 5 during the census has a calculated dose or dose commitment greater than the sites currently monitored for the same exposure pathway. If a new location with a higher dose commitment was found, routine sampling of that dose pathway would be initiated at that new site. The results of the 2009 land use census within five miles of CGS are presented in Table 4-3. No significant changes from the 2008 landI use census were observed. 4.4 Sampling Methods I Energy Northwest personnel collect environmental samples in accordance with the program plan outlined in Table 4-1. Methods of sample collection and TLD handling are specified in REMP specific a procedures. Most REMP samples collected in 2009 were prepared and analyzed at the Energy Northwest Environmental Services Laboratory located at the APEL facility in Richland, WA. The section 4.4 subsections below give a general overview of the sampling methods used in the REMP. I Generic descriptions of the REMP sample analysis methods are given in section 4.5. 4.4.1 Direct Radiation Direct radiation dose levels are monitored with Harshaw Model 8807 thermoluminescent dosimeters (TLDs). Two sets of TLDs are placed in the field approximately three feet above the ground at each monitoring station. One set of TLDs is exchanged on a quarterly basis (Quarterly TLDs); the other is exchanged on an annual basis (Annual TLDs). The locations of the TLD stations are listed in Table 4-2 and are shown in Figures 4-1 through 4.4. Station 9A in Sunnyside, serves as a control for CGS TLDs. Station 1 19C serves as the control for Station II 9B (the cooling tower sediment disposal basin). The remaining TLDs deployed in the field serve as indicator TLDs. The TLDs are arranged in a series of rings that encircle CGS. The innermost ring of TLD stations, which are located inside the CGS site boundary at distances that range from 0.3-0.8 miles from the u reactor building centerline, are referred to as the 'S stations.' The next ring of TLDs, referred to as the "near plant" stations, are located at distances ranging from 0.9 to 2.1 miles from the reactor building. The outer ring of TLDs are located at distances that range from a little under three miles to around tenl miles. A Thermo MicroRem dose rate meter is available as a backup device and to take real time readings as needed. 3 4.4.2 Airborne - Particulate/Iodine Weekly air particulate and air radioiodine (1-131) samples are obtained through the use of low volume 3 (1.5 cfm), constant flow-rate sampling units located at 12 locations. The samples collected at station 9A (Figure 4-3) are considered controls, the samples collected at the other locations (Figures 4-1, 4-2, and 4-3) are indicators. Air particulate samples are collected using 47mm diameter glass fiber filters, air1 iodine samples are collected using Radeco CP-100 TEDA impregnated charcoal cartridges. The air particulate filter and charcoal cartridge are placed in tandem, particulate filter first, in a holder that 2009 Annual Radiological Environmental Operating Report 4-2 Energy Northwest/Columbia Generating Station ii

attaches to the air inlet of the sampler unit. The sampler units are placed in ventilated metal weatherproof housings mounted on elevated platforms at each air sample location. The filter media are changed weekly. Four additional air sample locations established to monitor remediation work at the DOE 618-11 burial site utilize similar equipment. 4.4.3 Water Water sampling is performed to meet the requirements in the ODCM and State of Washington EFSEC requirements, comply with NEI guidelines, or a CGS initiative. REMP water sampling can be categorized as follows:

  • Intake-River/Drinking Water; two locations (Stations 26, and 29)
  • Deep Groundwater; three locations (Stations 52, 31, and 32)

Shallow Groundwater; eleven locations (MW-3 and MW-5 through MW-14) " Plant Discharge Water; one location (Station 27) Storm Drain Water; one location (Station 101) " Sanitary Wastewater; two locations (Stations 102A, and 102B) The sample at Station 26 is obtained using a composite sampler that draws water from the plant intake water system (TMU). The source of this water is the Columbia River. The station serves as a control location, as it is upstream of the plant discharge location, and also as a drinking water location as drinking water for CGS comes from this source. Station 29 is a composite sampler located at the Richland Water Treatment Plant located 11 miles downstream of the plant discharge. Station 29 is an indicator station for both river and drinking water. The ODCM requirement for a downstream water sample "near but beyond the mixing zone" is conservatively met by Station 27, a composite sampler that collects water from the cooling tower discharge line just prior to final discharge into the Columbia River. This sample reflects the radioactivity present in the plant discharge prior to any river dilution, rather than the concentrations that would be found after dilution in the mixing zone. Composite samples from Stations 26, 27, and 29 are collected monthly and analyzed for gamma emitting radionuclides, gross beta, and tritium. Three drinking water wells within the vicinity of CGS are used as groundwater sampling locations. These include a deep well on the CGS site, Station 52 located 0.1 mile north of the reactor building, and two deep wells at the IDC (ENW Industrial Development Complex), Station 31 and Station 32 located 1.2 miles down gradient from CGS. Water from Station 52 can be used as a backup source for drinking water and fire protection. The IDC wells supply water for drinking and fire protection at the IDC site. All of these wells are considered indicator locations. Quarterly grab samples are collected from each well and analyzed for gamma emitting radionuclides and tritium. Station 101 is a composite sampler that collects a representative sample of water flowing into the storm drain pond located east of CGS. The main source of this water is storm water runoff and discharges from the potable water and the plant makeup water demineralizer treatment systems. Additional discharges from CGS that have been verified to meet radiological environmental discharge limits may also be made to this location. Water is collected monthly using a flow-proportional composite sampler and analyzed for gross beta, gamma emitting radionuclides, and tritium. 2009 Annual Radiological Environmental Operating Report 4-3 Energy Northwest/Columbia Generating Station

I The Sanitary Waste Treatment Facility (SWTF) receives sanitary waste water from CGS, the IDC (ENW Industrial Development Complex), the Kootenai Building, and the DOE 400 Area. Discharge standards and monitoring requirements for the SWTF are established in EFSEC Resolution 300(15). Station 102A is a flow meter and composite sampler located on the DOE 400 Area sewer line before it I ties into the sewer lines coming from Energy Northwest facilities. A portion of the water used in the 400 Area is drawn from aquifers that are known to be contaminated with tritium as a result of past DOE activities on the Hanford Site, consequently, the water sampled at Station 102A has tritium I concentrations normally above 2000 pCi/liter. Station 102B is a composite sampler that collects a representative sample of water flowing into the head works at the SWTF. The sample obtained here contains water from all the Energy Northwest facilities mentioned above and the DOE 400 area. I Monthly samples are collected at both Stations 102A and 102B and analyzed for gross alpha, gross beta, tritium, and gamma emitting radionuclides. 3 Beginning in 2009, routine quarterly grab samples were taken as part of the REMP from a number of groundwater monitoring wells surrounding CGS. The monitoring well locations are shown in Figure 4-

1. All are shallow wells that allow sampling from the unconfined aquifer under CGS. None of the wells are used for drinking water. Sampling from these locations is performed to meet NEI 07-07 guidelines(21) and requirements in the CGS NPDES permit.

3 4.4.4 Soil Annual soil samples are collected at the indicator Stations 1,7, 21, and 23 as required by EFSEC I Resolution 260(b). A sample is also collected at a control location, Station 9A (Figure 4-3). Each sample is collected from an area of approximately one square foot to a depth of approximately one inch. About two kilograms of soil are collected for each sample. Soil samples are analyzed for gamma I activity on a dry weight basis. 4.4.5 Sediment River sediment samples are collected semiannually as required by the ODCM and EFSEC Resolution 260(6). The upstream sediment sample location (Station 33) is approximately two miles upriver from the plant discharge. The downstream sample (Station 34) is collected approximately one mile downstream from the plant discharge. Each sample consists of approximately two kilograms of the shallow surface sediment scooped from below the waterline. Sediment samples are dried in an oven and then analyzed for gamma emitting radionuclides on a dry weight basis. Cooling tower sediment samples are collected and analyzed whenever cooling tower sediment is added to the disposal cells (Station I 19B, Figure 4-1). Disposal in the Station 1 19B cells is made in accordance with EFSEC Resolution No. 299(6). Wet cooling tower sediment samples are collected and analyzed prior to transfer to the disposal cells. Following transfer, the material is allowed to dry then an additional sample is collected within 30 days of the disposal date and analyzed. 4.4.6 Fish Annual fish sampling is usually performed in late fall. Fish samples collected from the Columbia River (Station 30) serve as indicator samples, whereas fish collected on the Snake River (Stations 38) serve as control samples. Only edible portions of the fish are used to prepare the sample for analysis. Fish samples are analyzed for gamma emitting radionuclides on a wet weight basis. 2009 Annual Radiological Environmental Operating Report 4-4 Energy Northwest/Columbia Generating Station a

Three categories of fish samples are collected; an anadromous species (either a salmon or steelhead), and two other species generally considered edible or potentially edible (such as carp, catfish, sucker, and whitefish) are collected at each location. Electro-shocking and netting is used for most fish collection. Anadromous species are usually collected at fish hatcheries. 4.4.7 Milk Milk samples are collected monthly during the fall and winter months (October through March). During the spring and summer months when cows are likely to be grazing or on fresh feed, milk samples are collected twice per month. Raw milk samples are collected within a few hours of milking and the samples are normally prepared and analyzed within four days. Milk samples were collected in 2009 from two locations. Station 36 in Franklin County serves as the indicator location and is the only dairy within a ten mile radius of CGS. Station 9B is in the Sunnyside/Grandview area and serves as the control location. 4.4.8 Garden Produce Samples of local garden produce are collected monthly during the growing season when the produce is readily available. When possible, three types of produce samples are collected; a root crop, a fruit, and a leafy vegetable. Control samples are usually obtained from the lower Yakima Valley. Indicator samples may be collected from any areas downstream of the CGS discharge where crops are irrigated with Columbia River water. These samples are designated as Station 37 and usually are collected in the Riverview area of Pasco. Additionally, apples are normally collected in late summer or early fall from Station 91, Rio Vista Farms, an orchard located on the Columbia River 4.3 miles ESE of CGS. A small garden/vegetation area supplying broadleaf samples is maintained by the Environmental Service personnel next to the SWTF and has been designated as Station 102G. A vegetation sample was also taken from a small park area near CGS (Station 103A) in 2009. Garden and vegetation samples are typically pur6ed in a food processor and then analyzed for gamma emitting radionuclides on a wet weight basis. Only edible portions are used for analysis. 4.5 Sample Analyses General descriptions of the procedures used to analyze REMP samples are provided in the following sections. The REMP TLDs were processed by Battelle at the Pacific Northwest National Laboratory (PNNL). Most REMP field samples were analyzed by Energy Northwest Environmental Services. Samples are normally collected and analyzed within a short time period to ensure required detection sensitivities are met and to provide timely results. Sample count times are conservatively calculated to ensure required a priori LLDs are achieved. Table 4-4 list the ODCM required LLDs and the nominal target LLD used in the Energy Northwest REMP program during 2009. 4.5.1 Analysis of TLDs The REMP TLDs are measured at the Pacific Northwest National Laboratory on a Harshaw Model 8800 hot gas reader. The reader is calibrated weekly and immediately prior to processing the environmental TLDs. The reader is calibrated with TLDs that have been given a known exposure from a Cs-137 source. Each group of environmental TLDs is processed with blank (freshly annealed) TLDs 2009 Annual Radiological Environmental Operating Report 4-5 Energy Northwest/Columbia Generating Station

I and spiked TLDs that have been given a known exposure. Exposure received by the field TLDs during transport is monitored with a set of 'trip' control dosimeters that accompany the field dosimeters to and from the field locations and while they are in storage. Another set of TLDs, the building controls, are used to determine the exposure of the TLDs at the storage location. The TLD exposure during 3 transport to and from the field was determined from the difference between the building control results and the trip control results. 4.5.2 Gross Beta Activity on Air Particulate Filters 1 Air particulate filters are counted directly in a gas flow proportional counter after a delay of several days to allow for the decay of radon and its progeny. Samples were counted using a Protean WPC-9550 instrument which allows automated sample counting and simultaneous alpha/beta determination. If gross beta activity is identified at greater than 10 times the yearly mean of the control samples, gamma isotopic analysis is performed on the individual samples as required by ODCM Table 6.3.1-1 2c. 4.5.3 Measurement of Gamma Emitting Radionuclidesn Gamma isotopic analysis allows identification and quantification of gamma-emitting radionuclides that may be attributable to CGS effluents. Shielded, high purity germanium (HPGe) detectors are used to assay environmental samples for gamma emitting radionuclides. All samples are counted in' standardized, calibrated geometries.

  • Liquids - Measured aliquots of the liquid samples are poured into appropriately sized Marinelli beakers. Results are reported in pCi/liter.

" Solids - Soil, sludge, and sediment samples are dried and if needed ground. Foodstuff, biota (fish), and vegetation, are chopped finely or pureed and then analyzed wet (no drying is I done). For foodstuff (including fish), only the edible portion of the sample is used. Measured aliquots of the solid samples are placed into tared containers and weighed. Results i are reported in pCi/kg. " Charcoal Cartridges - Typically four charcoal cartridges are counted simultaneously using a cartridge holding jig that positions the cartridges in a standardized geometry to the side of the detector. Detector calibration files are maintained for both face mount and side count positions. Sample volume for each cartridge group count is conservatively set to the lowest cartridge sample volume in the group. If 1-131 is identified in the assay of a group, each charcoal cartridge in the group is assayed separately. Results are corrected for decay during the sample collection period. Results are reported in pCi/m3..

  • Air Particulate Filters - At the end of each quarter, air particulate filters are composited on a station by station basis. The filters are stacked in a Petri dish and analyzed by gamma spectroscopy. Results are reported in pCi/mn 3 and represent the total quarterly gamma activity I

collected at each station. Results are decay corrected to the midpoint of the sample collection period. If a radionuclide related to CGS operation is positively identified, the filters are separated and counted individually. 2009 Annual Radiological Environmental Operating Report 4-6 Energy Northwest/Columbia Generating Station ,I

4.5.4 Gross Alpha and Gross Beta Activity in Water A measured aliquot of each sample is evaporated to a small volume then quantitatively transferred to a ribbed, stainless steel planchet. Final evaporation is done under a heat lamp. Residue mass is determined by weighing the planchet before and after mounting the sample. The planchet is counted for alpha/beta activity using a Protean WPC-9550 automatic gas flow proportional counter which allows automated sample counting and simultaneous alpha/beta determination. Results are corrected for sample self-absorption using the sample residue mass values. Results are reported in pCi/liter. 4.5.5 Tritium in Water The sample is distilled, then 8.OmL of the distillate is mixed with 12.OmL of scintillation cocktail. The sample mixture is analyzed on a Packard Tri-Carb 2900TR automatic liquid scintillation counter. Results are reported in pCi/liter. 4.5.6 Sr-90, Fe-55 and Ni-63 in Water Shallow well water samples from the 1 st and 2 nd quarters were analyzed for these constituents by Teledyne Brown Radiological Laboratory Services using standard procedures developed by this vendor for these analyses. 4.5.7 Low Level Iodine-131 in Milk and Water Four liters of sample are first equilibrated with stable iodide carrier. Anion exchange resin is added to remove any iodine from the sample. The resin is isolated from the liquid sample and transferred to a small counting container. The iodine content is then determined by gamma spectroscopy analysis. Results are reported in pCi/liter. 4.6 Data Analysis Methods Counting results for low level samples are often within the counting error of the background determination; consequently results can range from negative to positive values in these samples. Though most REMP analytical results are below the detection limit, an actual calculated value has been reported. In some cases the reported value is zero or a negative number. Reporting results in this manner is a common practice in environmental analysis as it gives an indication of positive or negative biases that may be present and prevents loss of individual results inherent in the use of "less than" (<) values. Also reported in most cases are the a posteriori MDA values. A nuclide is flagged as positively identified if its calculated value is greater than the MDA. A listing of the Energy Northwest nominal target LLDs (a priori) for each sample type is provided in Table 4-4; the ODCM required LLDs are also included for a comparison. Data is trended following analysis for many of the sample types analyzed. For analyses such as gross beta on air particulate filters where results are normally above the detection limit, indicator results are plotted with the control results for easy comparison. Analysis results that are normally below detection limits are plotted against historical data to monitor if trends may be evident. Thermoluminescent dosimeter (TLD) data is presented in terms of the net mR/day exposure rate. These results are determined from the total exposure (in mR) calculated for each TLD minus the TLD background and any transit (or trip) exposure received during distribution and retrieval, and divided by the number of days the TLD was in the field. The total mR/standard quarter and mR/year values are 2009 Annual Radiological Environmental Operating Report 4-7 Energy Northwest/Columbia Generating Station

also reported (see Tables 5-3, 5-4). All TLD results are reported in units of exposure (Roentgen) and not in units of dose (Rem). The quarterly TLD results are compared with the annual TLD results and expressed as a ratio by dividing the sum of the quarterly results over the annual results (See Appendix A, Table A-1.1). The agreement between the two sets is usually within plus or minus ten percent (10%); occasionally fade can be more significant than expected in the annual set and the results may be lower than the sum of the quarterly data. 4.7 Changes to the Sampling Program in 2009 There were no major changes made to ODCM or EFSEC Resolution 260 mandated sampling in 2009. Sampling and analysis of shallow groundwater wells around CGS was made a routine part of the REMP. A new sample location near CGS was established (Station 103A) to provide vegetation samples at CGS Chemistry Effluents request. A TLD location (Station 58) was added as part of the CGS effort to monitor remediation work at the DOE 618-11 burial ground. An annual sediment/sludge sample from the SWTF was not taken in 2009. The sample is not required by EFSEC Resolution 300 and obtaining the sample presented health and safety concerns. I I I 1 I i I I I i I I I I I I I I 2009 Annual Radiological Environmental Operating Report 4-8 Energy Northwest/Columbia Generating Station

TABLE 4-1 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM SAMPLING PLAN SAMPLE METHOD AND SAMPLE STATION (b) COLLECTION TYPE AND FREQUENCY OF SAMPLE TYPE(a) NUMBER FREQUENCY(c) ANALYSIS AIRBORNE Particulates and 1,4-8, 9A, 21,23, 40,48, Continuous sampling; weekly Weekly air filter gross beta and radioiodine (6/1 2)(d) and 57 collection. iodine cartridge gamma isotopic. Quarterly air filter composite gamma isotopic. DIRECT RADIATION TLD0)(34/79) 1-8, 9A, 10-25, 40-47, 49-Continuous monitoring, quarterly Radiation exposure monitoring 51, 53-56, 58, 65, 71-90, and annual collection, processed on a quarterly and 119B, 119C, 120-129, annual frequency. 136A-138A, 150-151. Pic (k) Various locations, as needed Continuous monitoring, as needed. Radiation exposure monitoring. As needed. WATERBORNE River/Drinking Water0') 26, 27 and 29 Composite aliquots'm); monthly Monthly gamma isotopic, gross (3/3) collection, beta, and tritium. l-131 () as _required. Storm Drain Water (0/1) 101 Composite aliquots(m), monthly Monthly gamma isotopic, tritium, collection, and gross beta. Sanitary Waste 102A, 102B Composite aliquots(m), monthly Monthly gamma isotopic, gross Treatment Facility collection. beta, gross alpha, and tritium. Water (0/2) Ground Water (2/3)(P) 31, 32, and 52 Grab sample performed quarterly. Quarterly gamma isotopic and tritium. Ground Water MW-3, 5-14 Grab sample performed quarterly. Quarterly gamma isotopic and Monitoring (0/11)(* tritium. SOIL AND SEDIMENT Soil(g)(0/5) 9A, 1, 7, 21 and 23 Grab sample performed annually. Annual gamma isotopic. St-90<() as needed. River Sediment (1/ 2 )(q) 33 and 34 Grab sample performed Semiannual gamma isotopic. semiannually. Sanitary Waste 102D Grab sample as needed. Gamma isotopic as needed. Treatment Facility Sediment (0/1)(n) Cooling Tower 119B, 1 19C Grab sample of dried sediment Gamma Isotopic as needed. Sediment Disposal Area within 30 days of disposal date. (0/2) INGESTION Milk(') (2/2) 9B, 36 Grab sample collected Gamma isotopic, 1-1 3 1, Sr-90.'s) semimonthly during grazing season, monthly at other times. Fish(') (2/2) 30, 38 Grab samples collected annually. Gamma isotopic. Garden Produce(u) (1/5) 9C, 91, 37, 102G, 103A(v) Grab samples collected monthly or Gamma isotopic. I_ ,__ at time of harvest. 2009 Annual Radiological Environmental Operating Report 4-9 Energy Northwest/Columbia Generating Station 2009 Annual Radiological Environmental Operating Report 4-9 Energy Northwest/Columbia Generating Station

I TABLE 4-1 FOOTNOTES: (a) The fraction in parentheses for each sample type indicates the ratio of ODCM-required sample locations to the total number of sample locations currently being monitored in the surveillance program. Additional sampling is performed to meet EFSEC Resolution 260 requirements and at ENW initiative. I (b) The underlined sample location designates a control station. (c) Sample collection is performed at a frequency specified in the ODCM and EFSEC resolutions. Some sampling referenced in Table 4-1 is performed at CGS initiative. Sample deviations are permnitted if samples are unobtainable due to hazardous I conditions, seasonal availability, malfunction of automatic sampling equipment, or other legitimate reasons. (d) The ODCM specifies six air sample locations and EFSEC Resolution 260 specifies nine. Not listed in Table 4-1 are four other air sample locations established to monitor remediation work at the DOE 618-11 burial ground. See Section 5.9.6 for details. I (f) Sampling is performed to meet NEI 07-07 guidelines and NPDES requirements. (g) Soil samples are collected at five air-sampling locations to satisfy EFSEC Resolution 260 requirements. This resolution also requires Sr-90 analysis be performed on any indicator soil sample having gamma results greater than ten times the resultI for the control location. Cs-137 activity has historically been used as the gamma results parameter. (j) TLD Stations 71-86 are not included among the 34 TLD stations required by the ODCM. Alternate designations for these stations are I S-16S. EFSEC Resolution 260 requires 25 or more TLD stations to be located within a 10-mile radius of CGS. (k) Pressurized ion chambers (PICs) may be used in place of or in addition to TLDs as per ODCM Table 6.3.1 -1 l b. (1) The term "river/drinking water" is used throughout this report because the drinking water is taken from the Columbia River. Station 26, CGS makeup water intake from the Columbia River is both an upstream water sample and the drinking water sample U location. Station 29 is a downstream drinking water sample. The Station 27 sample, which is drawn from the plant discharge line, is taken in place of a "downstream" water sample near but beyond the mixing zone. It reflects the radioactivity present in the plant discharge prior to any river dilution. EFSEC Resolution 260 requires two drinking water locations downstream from the plant discharge and requires sampling from the plant intake and discharge water. Only one drinking water station is now I sampled after DOE closed the intake at the 300 Area (Station 28) in 1998. (in) Composite samples are collected using automatic sampling equipment that collects an aliquot at time intervals that are short relative to the compositing period. I (n) A sediment sample from the SWTF has historically been taken annually, however there is no ODCM or EFSEC requirement to perform this sampling. No sediment was removed from the SWTW in 2009 and no sediment sample was collected or analyzed. (o) When the dose calculated via ODCM methodology for consumption of water exceeds I mrem per year, low level 1-131 analyses 3 are performed on the drinking water samples. (p) EFSEC Resolution 260 requires sampling from wells used for fire protection and as backup drinking water sources. (q) EFSEC Resolution 260 requires sediment sample collection upstream and downstream of the plant discharge. (r) Milk samples will be obtained from farms or individual milk animals that are located in the most prevalent wind directions from CGS. EFSEC Resolution 260 requires at least three milk locations within the 10-mile radius of the plant and one in a control location, however, ENW currently has access to only one dairy within a 10-mile radius of the plant (Station 36) and one control I location at 30 miles. Broadleaf vegetation can be sampled in lieu of milk if a representative milk sample is not available. (s) ODCM Table 6.3.1-1 4k requires that if Cs-i 34 or Cs-137 is measured in an individual milk sample in excess of 30 pCi/I iter, then a Sr-90 analysis will also be performed. (t) Station 30 is the Columbia River and station 38 is the Snake River. If an impact is indicated, sampling will be conducted semiannually per ODCM Table 6.3.1-1 4i. There are no species fished commercially in the Hanford Reach of the Columbia River. The most recreationally important species in the area are anadromous, which ascend rivers from the ocean for breeding. Anadromous fish species are normally obtained from hatcheries; Snake River samples are obtained from the Lyons Ferry Fish I Hatchery, and Columbia River samples are obtained at the Ringold Fish Hatchery. (u) Garden produce is obtained from farms or gardens that use Columbia River water for irrigation. One sample of a root crop, leafy vegetable, and a fruit is collected each sample period, when available. The variety of the produce obtained will be dependent on I seasonal availability. (v) Station 91 is an apple orchard irrigated with Columbia River water that is normally sampled at harvest. Station 102G is a small garden/vegetation area located by the SWTF. Station 103A is a small park area located by the Kootanai building (EOF). Station 102G is maintained by REMP personnel and used to provide broad leaf vegetation samples, sampling at station 103A involves collection of broadleaf vegetation from trees and shrubs. Both stations are sampled at the request of CGS Chemistry effluents, neither station meets the ODCM criteria for a garden requiring sampling. 2009 Annual Radiological Environmental Operating Report 4-10 Energy Northwest/Columbia Generating Station I

TABLE 4-2 REMP SAMPLE STATIONS AND REQUIREMENTS STATION DISTANCE SECTOR"a) NUMBER(" MILES(c) ODCM(d) STATE"') OTHER'o N (1) 52 0.07 DGW DGW 71(IS) 0.28 TLD 47 0.70 TLD 57 0.70 AP/AI 18 1.16 TLD TLD 53 7.54 TLD NNE (2) 72(2S) 0.32 TLD 2 1.45 TLD TLD 54 6.08 TLD NE (3) 73(3S) 0.54 TLD 19 1.74 TLD TLD 48 4.59 AP/AI AP/Ai 46 4.99 TLD MW-9 0.22 SGW ENE (4) 74(4S) 0.38 TLD 21 1.45 TLD, SO AP/AI 20 1.93 TLD TLD 11 3.16 TLD 33 3.44 SE 45 4.45 TLD 44 5.90 TLD 101 0.22 SW MW-7 0.30 SGW MW-8 0.26 SGW MW-I 1 0.10 SGW E (5) 75(5S) 0.37 TLD 22 2.08 TLD 10 3.16 TLD TLD 26 3.19 SW, DW SW 27 3.19 SW DIS W 30() 3.5 FI FI 43 5.16 TLD 151 (Site 4) 0.83 TLD MW-12 0.12 SGW ESE (6) 76(6S) 0.42 TLD 31 1.06 DGW DGW 32 1.27 DGW 51 2.14 TLD 2009 Annual Radiological Environmental Operating Report 4-11 Energy Northwest/Columbia Generating Station

TABLE 4-2 (cont.) REMP SAMPLE STATIONS AND REQUIREMENTS STATION DISTANCE SECTOR"'a NUMBER"') MILES"c) ODCM(d) STATE'e) OTHERl0 ESE (6)(cont.) 23 3.03 TLD, AP/AI, SO 34 3.32 SE SE 8 4.39 TLD, AP/AI TLD, AP/AI 91 4.30 GP 42 5.85 TLD 36 7.33 MI MI 5 7.72 TLD AP/AI 38(g) 26 FI FI 150 (Site 1) 0.90 TLD SE (7) 77(7S) 0.57 TLD 24 1.87 TLD TLD 3 2.06 TLD 41 5.79 TLD 40 .6.51 TLD, AP/AI AP/AI MW-14 0.58 SGW SSE (8) I 19C 0.28 TLD 120 0.32 TLD, SE 102B 0.50 SFW 102D 0.50 SFW, SE 102G 0.56 GP/VE 78(8S) 0.81 TLD 25 1.50 TLD TLD 55 6.05 TLD 4 9.57 TLD, AP/AI TLD, AP/AI 29 11.57 DW DW 37(h) 16 GP GP MW-6 0.33 SGW MW-13 0.52 SGW S(9) 119B 0.31 TLD, SE 102A 0.67 SFW 79(9S) 0.76 TLD 1 1.25 TLD TLD, AP/AI, SO 6 7.72 TLD TLD, AP/AI 65 8.87 TLD SSW(10) 80(10S) 0.83 TLD 50 1.26 TLD TLD 56 6.65 TLD MW-3 0.31 SGW U I I I I I I I I I I I I I I I I 1 I 2009 Annual Radiological Environmental Operating Report 4-12 Energy Northwest/Columbia Generating Station

TABLE 4-2 (cont.) REMP SAMPLE STATIONS AND REQUIREMENTS STATION DISTANCE SECTOR(a) NUMBER(") MILES(c) ODCM(d, STATE"e) OTHER"0 SW (11) 13 1.26 TLD TLD 81(1IS) 0.74 TILD 103A 0.63 VE 90 0.62 TLD, AI/AP MW-5 0.43 SGW WSW(12) 82(12S) 0.57 TLD 14 1.26 TLD TLD 9A 28.35 TLD, AP/AI TLD, AP/AI, SO 9B 32.82 MI MI 9CO) 32 GP 89 0.23 TLD, AI/AP 58 0.44 TLD W (13) 83(13S) 0.52 TLD 15 1.24 TLD TLD WNW(14) 84(14S) 0.55 TLD 16 1.21 TLD TLD 7 2.83 TLD TLD, AP/Ai, SO 88 0.17 TLD, AI/AP MW-10 0.07 SGW NW(15) 85 (15S) 0.43 TLD 49 1.19 TLD TLD 87 0.20 TLD, AI/AP NNW(16) 121 0.12 TLD 122 0.31 TLD 123 0.29 TLD 124 0.28 TLD 125 0.28 TLD 126 0.28 TLD 127 0.26 TILD 128 0.25 TILD 129 0.17 TLD 136A 0.29 TILD 137A 0.24 TLD 138A 0.17 TLD 86(16S) 0.31 TLD 17 1.19 TLD TLD 12 6.74 TLD 2009 Annual Radiological Environmental Operating Report 4-13 Ene rgy Northwest/Columbia Generating Station

TABLE 4-2 (cont.) REMP SAMPLE STATIONS AND REQUIREMENTS TABLE 4-2 SAMPLE TYPE KEY AP/AI - Air Particulate/Air Iodine Dis W - Discharge Water GP - Garden/Orchard Produce MI - Milk SFW - Sanitation Facility Water SW - Surface Water VE - Vegetation DW - Drinking Water FI - Fish DGW - Deep Ground Water SE - Sediment SO - Soil TLD - Thermoluminescent Dosimeter SGW - Shallow Ground Water TABLE 4-2 FOOTNOTES: (a) The area in the vicinity of CGS is separated into 16 sectors for reporting purposes. The 16 sectors cover 360 degrees in equal 22.5 degree sections, beginning with sector I (N) at 348.75 to 11.25 degrees and continuing clockwise through sector 16 (NNW). (b) Alternate designations for station is given in parentheses; i.e., TLD Stations 71-86 are also referred to as I S-16S. (c) Distances are from GPS positions for each location as a radial distance from CGS reactor building. (d) ODCM - Offsite Dose Calculation Manual Table 6.3.1-1 requirement. (e) STATE - State of Washington EFSEC Resolution requirement. (f) OTHER -Special study stations. TLD Stations 121 through 138 satisfy ISFSI monitoring requirements IOCFR72.44(d)(2). Sampling at MW locations performed to meet NEI 07-07 guidelines and NPDES requirements. (g) Station 30 is the Columbia River at the vicinity of the plant discharge. Actual distance of fish collection locations from plant are variable, distance listed is approximation. Station 38 is the Snake River. Control resident fish are typically collected at variable locations in area below Ice Harbor Dam, distance listed is approximation. Control anadromous fish are typically collected at Lyons Ferry Fish Hatchery. (h) Fruit and Vegetable indicator samples are typically collected from farms and gardens in the Riverview area of Pasco. Distance listed here is general distance of Riverview area to Plant. Note station 37 encompasses any area downstream of plant discharge that irrigates with Columbia River water. (i) Station 9C is the designation given for control fruits and vegetables. Distance listed is general distance to the Sunnyside-Grandview area where the majority of the control fruits and vegetables are obtained. Note station 9C may indicate any area that does not irrigate with Columbia River water. I I I I I I 5 I I I I 3 I I I I I 2009 Annual Radiological Environmental Operating Report 4-14 Energy Northwest/Columbia Generating Station I I

TABLE 4-3 2009 FIVE MILE LAND USE CENSUS RESULTS NEAREST GARDEN SECTOR(a) RESIDENT"' (>500 ft2) DAIRY ANIMALS LIVESTOCK NE 4.47 none none none ENE 4.01 none none 4.96 E 4.59 none none none ESE 4.24 none none none SE none none none none FOOTNOTES (a) Within a five-mile radius of the plant, only 4.5 sq. miles of the land in the sixteen meteorological sectors is privately owned farmland. The remainder of the land is on the federally owned Hanford Site. Only those sectors containing points of interest are presented here. (b) Estimated distances in miles from CGS Reactor Building based on GPS readings. 2009 Annual Radiological Environmental Operating Report 4-15 Energy Northwest/Columbia Generating Station

TABLE 4-4 1 COMPARISON OF LABORATORY NOMINAL LOWER LIMITS OF DETECTION WITH OFFSITE DOSE CALCULATION MANUAL REQUIREMENTS 3 ENERGY ODCM REQUIRED MEDIA (UNITS) ANALYSIS NORTHWEST LLDs LLDS'a) Air Gross Beta 0.002 0.01 (pCi/m3) Cs-134 0.001 0.05 Cs-137 0.001 0.06 1-131 0.03 0.07 Water: (pCi/liter) Soil/Sediment: (pCi/kg dry) Gross Beta Tritium Sr_90(') Ni_63(d) Fe_55(d) 1-131(c) Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Mn-54 Co-60 Zn-65 Cs-134 Cs-137 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Cs-134 Cs-137 1-31 (c) Cs-134 Cs-137 Ba-La-140 Sr-90 Cs-134 Cs-137 1-131 2.4 300 1 5 200 1 7 10 7 7 10 7 7 7 10 20 20 30 20 20 10 25 100 35 25 50 30 25 0.5 7 7 10 I 10 10 12 4 2000(') 15 30 15 15 30 15 15 18 15 150 180 130 260 130 130 260 130 150 1 15 18 15 60 80 60 Fish: (pCi/kg wet) UI I I I I 1 I I I I I I I I I I I I Milk: (pCiliter) Garden Produce: (pCi/kg wet) (') These are the nominal target LLDs (a priori) for analyses performed in the Energy Northwest Environmental Services Laboratory and are based on conservative assumptions. These calculations included corrections for decay during the collection period and delay prior to analysis using factors that are normally encountered for the different media types. Actual LLDs (a posteriori ) may be higher or lower for specific samples. (b) If no drinking water pathway exists, a value of 3,000 pCi/liter may be used. (c) This ENW 1-131 LLD achieved by anion resin separation and does not represent a direct analysis of the sample media. ) These are the target LLDs used by Teledyne-Brown for the ground water samples analyzed in the I" and 2 nd quarters. 2009 Annual Radiological Environmental Operating Report 4-16 Energy Northwest/Columbia Generating Station

0 0.5 i II Miles Miles A72 A84 V/~///// A83 A 82 A90 58 [ Q O~oOo ok 0 [ a D A 9 W2 A 1190 A

  • W*

119B 120 W4 U0W A 73 A 74 A 75 A 76 a W5 W 13 102b mA W 1477 A81 0 1 02a A80 A 7q A78 0 Water Sample Sediment L Facilities TLD Security Barrier / DOE Burial Ground 9 Air Sample Deep Well Reactor Building ISFSI Shallow Well City Limits ] Water FIGURE 4-1 SELECT REMP SAMPLING LOCATIONS WITHIN 0.8 MILES OF CGS 2009 Annual Radiological Environmental Operating Report 4-17 Energy Northwest/Columbia Generating Station

0I 2.5 1 51 Miles Coumtba RFl 33 2 A 19 18 A A 49 A 16 A 20 A 14A 15 14 el 0 ý 0 21 1tl 31 32 150¶t0 oo 22 - 26,27 10 34 51 23 A 13 50 1 3 A 25 A 24 I I I I I I I U I I I I I I I I I 1 I (//X N Water Sample Sediment L Facilities A TLD Air Sample Security Barrier '7 DOE Burial Ground Deep Well Reactor Building ISFSI Shallow Well [ City Limits Water FIGURE 4-2 SELECT REMP SAMPLING LOCATIONS BETWEEN 0.8 AND 2.8 MILES 2009 Annual Radiological Environmental Operating Report 4-18 Energy Northwest/Columbia Generating Station

FIGURE 4-3 SELECT REMP SAMPLING LOCATIONS BEYOND 2.8 MILES 2009 Annual Radiological Environmental Operating Report 4-19 Energy Northwest/Columbia Generating Station

250 ft ST.123 ST.124 ST.125 Isolation Fence Security Fence r----------------------------------- Electrical Cntrl Bldg 135 ft ST. 126 +ST.127 Dry Fuel Cask ST. 4, 1, 0 0370 0 T. +ST.829 +------------------------ 4 ----


+ ------

ST. 136A ST.137A STl. 138A + REMP TLD FIGURE 4-4 ISFSI TLD STATION LAYOUT 2009 Annual Radiological Environmental Operating Report 4-20 Energy Northwest/Columbia Generating Station

5.0 RESULTS AND DISCUSSION

5.0 RESULTS AND DISCUSSION The Columbia Generating Station environmental TLDs were collected by Energy Northwest Environmental Services personnel and analyzed by Battelle at the Pacific Northwest National Laboratory (PNNL). Sr-90, Fe-55 and Ni-63 analysis were performed by Teledyne-Brown in Knoxville, TN. All other CGS REMP samples were analyzed by the Energy Northwest Environmental Services Laboratory located in Richland, WA. Table 5-2 provides a summary of the ODCM required REMP sample and CGS groundwater monitoring analysis results in the format specified in Regulatory Guide 4.8. Results for naturally occurring radionuclides that are not related to CGS operations have not been included in the summary table. The lower limits of detection (LLDs) listed in Table 5-2 are the ODCM required detection limits and are not the method detection limits listed in Table 4-4. Analytical results for all REMP samples are presented in Appendix A of this volume and summarize the results in greater detail. 5.1 Direct Radiation Direct radiation is monitored at 79 TLD locations surrounding CGS. TLDs are exchanged on a quarterly and annual frequency at all locations. The 16 locations designated as "S" stations are located between 0.3 and 0.8 miles from the CGS reactor building and all are inside the property boundary, see Figure 4-1 for station locations. Figure 5-1 presents the 2009 "S" station mean quarterly TLD results separated into sixteen geographical sectors around the plant. Figure 5-1 also shows the high, low, and mean result in each sector for 1984 through 2008 for comparison. The results in the N, NNE, and NNW sectors show higher exposure rates than most other "S" stations as a result of being physically closer to the ISFSI and the plant turbine building. The highest results were found in the NNW sector with this sector being the only one with results above the sector long term average. The NNW location is the closest "S" station to the ISFSI and higher results here are attributed to the stations close proximity to this facility. 0.36 _S-Stations 0.33 0.30 TTT E 0.27 E 0.24 :...O-J 9 0.21 0.18 0.15 T T - N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW o Pro-Operational Mean 2009 Mean 1984-2008 High/Low/Mean Figure 5-1 Site Boundary Quarterly TLDs 1984-2008 Hi/Low/Mean and 2009 Mean by Sector 2009 Annual Radiological Environmental Operating Report 5-1 Energy Northwest/Columbia Generating Station

TLDs in most all other sectors show results below the preoperational and long term sector average, a pattern that has been observed since 2003. Excluding the NNW sector, the average deviation relative to the preoperational period was -3.5%. Exposure rates for 19 near plant TLD locations are presented in Figure 5-2. These TLDs are located at distances between 0.9 and 2.1 miles from the reactor building, see Figure 4-2 for station locations. Results for all but one sector were below the preoperational and long term operational means. The average deviation relative to the preoperational period was -2.8%. 0.36 Near Plant Stations 0.33 0.30 t 0.27-E 0.24-0.21 0.18 j....i I-i 0.15 N NNE NE ENE E ESE SE SSE S Mean -&- 2009 Mean SSW SW WSW W WNW NW NNW 1984-2008 High/Low/Mean o Pre-Operational I Figure 5-2 Near Plant Stations Quarterly TLDs 1984-2008 Hi/Low/Mean and 2009 Mean by Sector Remote Stations I I I I I I I I I I I I I I I I I I I 0.36 0.33 0.29 0.26 E 0.22 0.19 0.15 S SSW WSW WNW NNW N NNE NE ENE E ESE SE SSE o Pre Operational Mean 1984-2008 High/Low/Mean N 2009 Mean Figure 5-3 Remote Quarterly TLDs 1984-2008 Hi/Low/Mean and 2009 Mean By Sector 2009 Annual Radiological Environmental Operating Report 5-2 Energy Northwest/Columbia Generating Station

Exposure rates for 22 remote TLD locations are presented in Figure 5-3, see also Figure 4-3 for station locations. Station 46 in the Wahluke Reserve (NE sector) remained the remote location with the highest exposure rate. This has been the case since the preoperational measurement phase and is attributed to differences in the underlying rock and soil composition in this area. Remote location results for all sectors were below the preoperational and long term operational means. A similar pattern has been observed since 2003. The average deviation relative to the preoperational period was -5.3%. Offsite direct radiation monitoring results are consistent with previous years. The 2009 results indicate no measurable dose contribution due to plant operations at locations outside the CGS controlled area. Dose contributions inside the CGS controlled area are limited to those locations known to be influenced by the Independent Spent Fuel Storage Installation (ISFSI) and/or radiation from the turbine building during operation. Environmental radiation exposure rates for 2009, the preoperational phase, and the long term operational phase are summarized in Tables 5-3 and 5-4. See also Appendix A, Tables A-1.1 and B-1.1 for comparisons of the 2009 annual and summed quarterly TLD results. TLD results for special interest locations are discussed in further detail in Section 5.9. 5.2 Airborne Particulate/Iodine Air samples are collected weekly from 11 sample stations located around CGS. Additionally, an air sample station located 28 miles WSW of CGS is used as a control for comparison. Air particulate filters are analyzed for gross beta and iodine cartridges for radioactive iodines on a weekly basis. Air filters are also composited and analyzed for gamma emitting nuclides quarterly. The 2009 average particulate filter gross beta results for the five stations sampled weekly and located within three miles of CGS are plotted in Figure 5-4 (See also Appendix A, Tables A-2. 1, A-2.2). Results for these locations are within the range observed in previous years and closely follow the trend observed for the control location. Near Plant Stations 0.16 0.14 WEEKS 19-23 FOR 1986 NOT INCLUDED DUE TO HIGH BIAS CAUSED BY CHERNOBYL. 0.12 0.10 0.08 0.06-0.04-0.02-t 0.00 WEIDK 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 HIGH/LOW/MEAN 1985-2008 6 MEAN 2009 Control 2009 Figure 54 1985-2008 Weekly Hi/Low/Mean and 2009 Weekly Mean Gross Beta in Air - Near Plant Stations 2009 Annual Radiological Environmental Operating Report 5-3 Energy Northwest/Columbia Generating Station

Figure 5-5 is a plot of the 2009 mean weekly particulate filter gross beta results for the 6 sample stations located between 3 and 9.6 miles from CGS (See also Appendix A, Tables A-2. 1, A-2.2). A similar trend to that seen with the near plant station was observed with all results trending closely to the control. A noticeable increase above the historic gross beta mean was observed in weeks 4, 8, 11, and 50 at all locations including the control. These increases are attributed to weather induced background fluctuations. As noted in previously reports, gross beta levels typically increase during periods of inversion occurring in the fall and winter months. Gross beta results plotted over a period of several years show a cyclical pattern of fall and winter increases. As the increases were seen at the control location also, the increases observed are due to background fluctuations and are not attributable to CGS operation. Remote Stations 0.16 0.14 0.12 0.10 4a 0.08-0.06-0.04-0.02-0.00 WEEK 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 I I I I I I I I I I I I I I I I I 1 I HIGH/LOW/MEAN 1985-2008 et MEAN 2009 Control 2009 Figure 5-5 1985-2008 Weekly Hi/Low/Mean and 2009 Weekly Mean Gross Beta in Air - Remote Stations The quarterly particulate filter gamma isotopic results identified the presence of only naturally occurring radionuclides (See Appendix A, Tables A-3. 1, A-3.2). Be-7 was positively identified in all samples at both the indicator and control locations. The 2009 weekly iodine cartridge isotopic results showed no indication of 1-131 in any of the samples with result in all cases being below the 1-131 lower level of detection (See Appendix A, Tables A-4.1, A-4.2). Based on these results, there is no evidence of any measurable environmental radiological air quality impact that can be attributed to CGS plant operation during 2009. 2009 Annual Radiological Environmental Operating Report 5-4 Energy Northwest/Columbia Generating Station

5.3 Water 5.3.1 Surface Water Composite water samples are collected from 6 surface water locations monthly and analyzed for tritium, gross beta, and gamma emitters. A plot of the 2009 gross beta results for the plant intake, plant discharge, and river/drinking water are shown in Figure 5-6. All drinking and river water (Stations 26 and 29) gross beta results were below the analysis method a priori LLD (See Appendix A, Tables A-5. 1, A-5.2). Gross beta levels in the plant discharge water (Station 27) were higher than the levels seen in the intake water (Station 26). This is the normal observation as natural radioactivity is concentrated in the discharge water due to evaporative loss and the scrubbing action of the cooling towers which incorporates atmospheric particulate material into the water. The relatively low gross beta results for Station 27 during the summer months reflects periods when CGS was shut down for outages and discharge water was at a low level of concentration. The discharge sample results are representative of the radioactivity present in plant discharge water before any mixing with river water occurs. Gross Beta in Water 2009 10.0 8.0 6.0 4.0 2.0 0.0 -2.0 - 1 2 3 4 5 6 7 8 9 10 11 12 Month --0--Station 26 -- a-Station 27 N-- Station 29 -Gross Beta LLD (2.4 pCi/I) Figure 5-6 Gross Beta in River/Drinking ( Stations 26 & 29) and Plant Discharge Water (Station 27) for 2009 Tritium results for all plant intake, plant discharge, and river/drinking samples were below the analysis method a priori LLD. (See Appendix A, Tables A-6. 1, A-6.2). This is consistent with results seen in previous years. Tritium results for the three sample locations are plotted in Figure 5-7. Gamma spectroscopy results for all plant intake, plant discharge, and river/drinking samples showed no indication of any gamma-emitting radionuclides of interest being present (See Appendix A, Tables A-7. 1, A-7.2). There is no evidence of significant impact to the environment due to CGS plant operations in the plant intake, plant discharge, or river/drinking water results analyzed in 2009. Composite water samples are also taken from two sanitary waste sample locations and one storm drain location. Analysis results for these samples are discussed in further detail in Section 5.9. 2009 Annual Radiological Environmental Operating Report 5-5 Energy Northwest/Columbia Generating Station 2009 Annual Radiological Environmental Operating Report 5-5 Energy Nonhwest/Columbia Generating Station

I Tritium in Water 2009 I 400 350 1 300 250 I 200 S150 1 1oo I 50 -50 1 -100 -,r 1 2 3 4 5 6 7 8 9 10 11 12 Month 3 -o-- Station 26 -G-Staion 27 ---- Station 29 - Tritium LLD (300 pCiA) U Figure 5-7 Tritium in River/Drinking ( Stations 26 & 29) and Plant Discharge Water (Station 27) for 2009 5.3.2 Ground Water I Samples from 3 deep wells are collected quarterly and analyzed for tritium and gamma emitting 3 radionuclides. Routine quarterly sample collection from eleven shallow groundwater monitoring wells located near CGS was also performed in 2009 as part of the CGS groundwater monitoring program. During the 1st and 2 nd quarters of 2009, the shallow ground water samples were analyzed for tritium, gross alpha/beta, gamma emitters, Sr-90, Fe-55 and Ni-63. During the 3rd and 4th quarters, these samples were analyzed for tritium and gamma emitters. Locations of the ground water wells are shown in Figures 4-1 and 4-2. Analytical results for the three deep water wells were consistent with results seen in previous years. No gamma emitting radionuclides of interest or tritium was identified in any of these 3 samples (See Appendix A, Tables A-6.1, A-6.2, A-7.1, and A-7.2). Analytical results for the eleven shallow monitoring wells are presented in Table 5-2 and Appendix A. Gamma Spectroscopy results for these samples did not identify any gamma emitting radionuclides of interest (See Appendix A, Tables B-10.1, and B-10.2). Results of the Sr-90, Fe-55 and Ni-63 analyses conducted during the 1st and 2nd quarters were all below the analysis methods minimum detectable concentration (See Appendix A, Table B-9. 1). Results from the gross alpha/ beta analysis conducted during the 1st and 2 nd quarter showed the presence of small quantities of gross alpha and beta present in most of these samples (See Appendix A, I Table B-12.1). Tritium concentrations in these samples ranged from < LLD to 17,000 pCi/liter (See Appendix A, Table B-11.1). Tritium results from each well were consistent during the year with the exception of well 7 results in the 2nd quarter and well 8 results during the 3d quarter U which were noticeably above the trend. 2009 Annual Radiological Environmental Operating Report 5-6 Energy Northwest/Columbia Generating Station

The CGS ground water monitoring program is conducted to meet the Nuclear Energy Institute (NEI) Groundwater Protection Initiative (NEI 07-07), (21) guidelines and to support NPDES licensing requirements. The eleven shallow wells allow water to be sampled from the unconfined aquifer around the CGS site. None of these monitoring wells are used as a source of drinking water. CGS is unique in the commercial nuclear power industry in that it is located in an area where the unconfined aquifer under the site is known to be contaminated with tritium as a result of past DOE activities on the Hanford Site(20). The CGS groundwater program is intended to assess any contribution CGS may be making to the known groundwater contamination issue. 5.4 Soil Gamma spectroscopy analysis was performed on soil samples from 5 different locations in 2009 (See Appendix A, Tables A-8. 1, A-8.2). Naturally occurring radionuclides ( K-40 and Bi-214) were identified in all samples and Cs-137 was identified in two of the samples, one being a sample from the control location. The level of Cs-137 identified was similar to that seen in the past and within the concentration range that is considered normal background levels for Hanford site soils.!.') No indicator location had Cs-137 concentrations high enough above the control location to require Sr-90 analysis. The soil sample results do not indicate any measurable impact from CGS plant operation. 5.5 River Sediment Gamma assays of river sediment identified naturally occurring radionuclides (K-40, Ra-226, Bi-214) and Cs-137 (See Appendix A, Tables A-9.1, 9.2). Cs-137 was detected in one upstream (Station 33) and both downstream (Station 34) samples (relative to the cooling tower discharge point). As observed in previous years, Cs-137 downstream activity was slightly higher than the activity identified upstream. Both the upstream and downstream Cs-137 activity levels identified are within the range quantified in previous years and consistent with known Cs-137 background levels in Hanford area sediment and soil] 19). The sediment sample results do not indicate any measurable impact from CGS plant operation. CGS has not made a radioactive discharge to the Columbia River since 1998. 5.6 Fish The gamma spectroscopy results of fish samples collected at both the indicator location (Columbia River) and the control location (Snake River) identified the presence of only naturally occurring radionuclides. (See Appendix A, Tables A-10.1, 10.2). These results are consistent with results seen from past years. 2009 Annual Radiological Environmental Operating Report 5-7 Energy Northwest/Columbia Generating Station

I I 5.7 Milk There was no 1-131 activity identified in any of the milk samples collected in 2009 (See Appendix A, Tables A-11.1, A-11.2). Gamma spectroscopy results of milk radionuclides other than 1-131 did not identify the presence of any radionuclides of interest above detection limits (See Appendix A, i Tables A-12.1, A-12.2). Naturally occurring K-40 was identified in all milk samples. I 5.8 Garden Produce Gamma analysis was performed on twelve different fruit and vegetable crops in 2009 (See I Appendix A, Tables A-15.1, A-15.2, A-16. l, A-16.2, A-17.1, A-17.2). No radionuclides of interest were identified in any of the samples. Naturally occurring K-40 was identified in all samples. 3 5.9 Special Interest Stations 3 Sampling and analysis is performed at the locations covered in this section to comply with EFSEC requirements or is performed at CGS initiative. The storm drain pond and the Sanitary Waste I Treatment Facility (SWTF) were incorporated into the routine sampling schedule in 1992. In 1995, the cooling tower sediment disposal area was added. TLDs were placed around the spray pond drain field (Station 120) in June 1995. TLD monitoring in the vicinity of the planned Independent I Spent Fuel Storage Installation (ISFSI) was first performed in 1998 to collect background data and TLD monitoring was established on the ISFSI fence line after construction was completed in 2002. Discussions of the results from each of the locations are given in the following sections. I 5.9.1 Storm Drain Pond (Station 101) The storm drain pond (NPDES Outfall 002) is located approximately 1500 feet northeast of CGS. Water is sent to the pond through an 18-inch diameter pipe that discharges into a 300-foot long earthen channel that leads to a 100-foot diameter pond. The pond is a shallow, unlined percolation/evaporation basin. Water at the storm drain outfall is sampled using a flow proportional automatic sampler to collect monthly composite samples. The storm drain pond area is fenced and access is restricted. Monthly water samples were analyzed for gamma emitting radionuclides, tritium, and gross beta. Gamma spectroscopy results did not identify the presence of any gamma emitting radionuclides of interest (See Appendix A Tables B-2.1, B-2.2). Gross beta was positively identified in only one of the twelve samples; the level identified was just above the detection limit and within the range observed in previous years. (See Appendix A, Tables B-3.1, B-3.2). Tritium was detected in six of the twelve samples (See Appendix A, Tables B-4.1, B-4.2). The samples with the highest tritium activity were from colder, wetter months which is consistent with results seen in previous years. The source of the tritium in these samples is believed to be from recapture of tritium from CGS effluents which is more likely to occur during cooler, rainier periods. Multiple Station 101 2009 Annual Radiological Environmental Operating Report 5-8 Energy Northwest/Columbia Generating Station iI

composite samples were analyzed in July. Emergent condenser repair work resulted in CGS discharging large amounts of water via this pathway during this time frame. 5.9.2 Sanitary Waste Treatment Facility (Station 102) The Sanitary Waste Treatment Facility (SWTF) is located approximately 0.5 miles south-southeast of the CGS. The facility processes sanitary waste water from CGS, the ENW Industrial Development Complex (formerly referred to as WNP-1 and WNP-4), the Kootenai Building, and the DOE 400 Area. Station 102B receives water from all these locations, Station 102A receives water only from the DOE 400 Area. Discharge standards and monitoring requirements for the SWTF are established in EFSEC Resolution No. 300(5). The monthly composite gross alpha and beta results for the DOE 400 Area effluent (Station 102A) and the SWTF head works (Station 102B) were consistent with results seen in previous years. Low level gross beta was identified in all samples, gross alpha was not identified above the LLD in any of the samples. (See Appendix A, Tables B-5.1, B-5.2, B-6.1, B-6.2). Gamma spectroscopy results of the monthly SWTF water samples identified 1-131 in the January Station 102B composite sample. AR/CR 192102 was written to document the finding. As no additional radioisotopes were identified in the sample, the determination was made that the source of the radioiodine was from a medically administered treatment. No other gamma emitting radionuclides of interest were detected in any of the other samples analyzed in 2009 (See Appendix A, Tables B-7.1, B-7.2). A Station 102D sediment sample (collected from the lined north stabilization pond) was not collected in 2009. Tritium activity was identified in most all of the SWTF Station 102A and 102B samples (See Appendix A, Tables B-8. 1, B-8.2). The tritium levels identified are consistent with levels identified in previous years. Station 102A results remain elevated as the source of this sample is partly from an unconfined aquifer that is known to be contaminated with tritium as a result of past DOE activities on the Hanford site(20 ). Tritium activity coming from the DOE 400 area is the main source of the tritium identified in the station 102B samples. 5.9.3 Cooling Tower Sediment Disposal Area (Station 119) EFSEC Resolution No. 299(16) authorizes the onsite disposal of sediments from plant cooling systems containing low levels of radionuclides. The disposal area for these sediments is located just south of the cooling towers. Resolution No. 299(16) requires direct radiation monitoring using quarterly and annual TLDs in the vicinity of the disposal cells and the collection and analysis of a dry composite sediment sample from the disposal cell within thirty days following each cleaning to confirm that the disposal criteria outlined in the resolution have not been exceeded. Cleaning of the cooling towers was performed in May 2009. Disposal of the material removed resulted in an estimated 131.6 cubic meters of dry sediment being placed into the 2007 disposal cell. In April, an estimated 4 cubic meters of dry material removed from Valve boxes 9 and 12 was placed into the 2005 disposal cell. Approval for this disposal was given by EFSEC. Figure 5-8 summarizes the estimated quantity of radionuclides that were placed in the disposal area in 2009. For those isotopes listed in the table that were not positively identified, the MDA value obtained 2009 Annual Radiological Environmental Operating Report 5-9 Energy Northwest/Columbia Generating Station

from the sample analysis was used in the table calculations. As such, the total activity reported should be considered a conservative estimate. All results are well below the disposal concentration limits specified in EFSEC resolution 299(16). Cs-137 is routinely identified in the sediment disposal samples and the CS-137 level identified in the 2009 samples were within the range seen in previous years and only slightly higher that the Cs-137 levels identified in Columbia River sediment (See Appendix A, Tables A-9.1 for comparison). Co-60 was not positively identified in any 2009 sample. 2009 Cooling Tower Sediment Disposal Data Disposal Date April 2009 May 2009 Pit ID: 2005 Pit 2007 Pit Mass, kg 4,388 71,314 Density, g/cc 1.43 0.542 Analytical Analytical Nuclide Limit (pCi/kg) Result (pCi/kg) Result (pCi/kg) Total Curies Co-60 5.OOE+03 < 2.66E+01 < 5.72E+01 < 4.20E-06 Mn-54 3.OOE+04 < 3.19E+01 < 5.59E+01 < 4.13E-06 Zn-65 5.OOE+04 < 5.97E+01 < 1.51E+02 < 1.1OE-05 Cs-134 1.OOE+04 < 2.57E+01 < 5.53E+01 < 4.06E-06 Cs-137 2.OOE +04 < 2.63E+01 2.14E+02 1.54E-05 3.88E-05 Figure 5-8 Cooling Tower Sediment Activity Levels For Disposals Made In 2009 Measurements of direct radiation at the disposal basin was taken using TLDs. Two locations were used, an indicator location next to the collection area (Station 119B) and a control location approximately 100 yards to the east (Station 119C). The mean quarterly and annual TLD results agree well with results from previous operational years. The negligible difference between the indicator and the control TLDs indicate that there was no measureable dose contribution above background due to material in the disposal cells. (See Tables 5.3, 5.4 and Appendix A, Tables B-

1. 1, 13-1.2).

5.9.4 Spray Pond Drain Field (Station 120) There were no discharges to the Spray Pond Drain Field (NPDES Outfall 003) in 2009. The TLD results at Station 120 in 2009 are in agreement with those seen in previous operational years (See Table 5-3, 5-4 and Appendix A, Tables B-1.1, B-1.2). 5.9.5 Independent Spent Fuel Storage Installation The Independent Spent Fuel Storage Installation (ISFSI) is a fenced, secured area north northwest of CGS. Ten TLD stations, stations 123,-129 and stations 136A-138A are located on the outer security fence surrounding the ISFSI. TLD station 122 is just north of the ISFSI between the ISFSI and the plant access road. TLD station 121 is located approximately 0.1 mile north of the plant between the Transformer Yard and the ISFSI. Refer to Figure 4-4 for ISFSI TLD locations. I I I I I I I I I I I I I I I i I I I 2009 Annual Radiological Environmental Operating Report 5-10 Energy Northwest/Columbia Generating Station

Radiological exposure rates at the ISFSI security fence are elevated and access to the area directly outside the fence requires radiological dosimetry and security notification to enter. In addition to the TLD monitoring program, quarterly radiological surveys of the ISFSI are conducted by the CGS Radiation Protection Department. No spent fuel storage casks were added to the ISFSI during 2009. As shown in Figure 5-9, exposure rates at the ISFSI fence line followed a leveling to downward trend during the year. Station 122 TLD results showed a similar pattern with the trend for this location correlating to the overall ISFSI TLD trend but at a lower level. The Station 121 TLD results showed a marked drop in the second and third quarters reflecting plant operational status. As noted in previous reports, the trend for this location is more influenced by turbine building radiation levels than by the ISFSI. (See Table 5-3, 5-4 and Appendix A, Tables B-1.1, B-1.2) Trend of Exposure Rates at ISFSI Fence Line 2.6 2.2 1.8 E 1.4 1.0 + 0.6 0.2... V,) '9? 'Q '(; 'Q VO 'Q QI 'QO 'Q '(Q; 'Q 'Q '07 9pI -125 -o-126 -+-127 -K-128 -o--129 --- 136A -e-137A - 138A ---c-123 -- -124 Figure 5-9 ISFSI TLD Trend at CGS (All TLDs located on outer security fence). 5.9.6 Additional Air Sample and TLD Locations Four additional air sample locations (Stations 87-90) and 5 TLD stations (Stations 58, 87-90) were established in 2008/2009 in order to monitor air quality and direct radiation during remediation work at the DOE 618-11 burial ground located just west of CGS (See Figure 4-1). Air samples were collected and TLDs were exchanged at these locations in 2009 though no remediation work took place at the burial ground during the year. Air particulate data from the four locations show no indication of any effects from CGS effluents (See Appendix A, Tables B-13.1 and B-14.1). Three of the TLD stations had results slightly higher than background due to the stations close proximity to the turbine building and the ISFSI (See Appendix A, Table B-I. 1). 2009 Annual Radiological Environmental Operating Report 5-Il Energy Northwest/Columbia Generating Station 2009 Annual Radiological Environmental Operating Report 5-11 Energy North west/Columbia Generating Station

I 5.10 2009 Sample Deviations A summary of the sample deviations from 2009 are listed in Table 5-1. Only those deviations that resulted in a CR being written, demonstrate a sample not achieving the required detection sensitivity, or represent a non-mechanical error are reported. TABLE 5-1 REMP Sample Deviations for 2009 SAMPLE MEDIA DATE LOCATION CR/AR ID PROBLEM / COMMENTS Sampler declared INOP for 10 Water Composite 193273 hours due to full containers. Sampler 194133 Sampling interval changed 4/14/09 to prevent reoccurrence. Sampler found off though Water Composite 5/26/09 Station 27 198121 blowdown was in progress. OPS Sampler contacted and sampler turned on. Plant in shut down. Wate CSampler off for - 54 hours for Water Composite 6/1/09 Station 27 NA planned power outage, blowdown Sampler in progress. Plant in shut down. Sampler off for - 16 hours though Water Composite 8/20/09 Station 27 203169 blowdown in progress. OPS Sampler contacted and sampler turned on. Plant in shut down. Power off at station for week due to sub station renovation. Not a Air Sampler 11/3/09 Station 5 NA ODCM or EFSEC required sample location. Power off for week due to planned Air Sampler 11/24/09 Station 23 NA power outage. This is EFSEC but not a ODCM required sample. Power off at station for week due to sub station renovation. Not a Air Sampler 12/15/09 Station 5 NA OC rESCrqie ODCM or EFSEC required sample location. Fish collected at control location Fish Annual 2009 Station 30, 38 212250 not in all cases same species as collected at indicator location. I I I I I I U I I I I I I I 2009 Annual Radiological Environmental Operating Report 5-12 Energy Northwest/Columbia Generating Station

TABLE 5-2 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

COLUMBIA GENERATING STATION DOCKET NO. 50-397 Benton County, Washington Calendar Year 2009 Medium: Environmental Direct R iation (TLD) Units: mR/period Location With Highest Annual Control Total Lower Limit of Indicator Locations Mean Number of Analysis Type Analyses Detection Mean (f)a a Nonroutine Performed (LLD) Range Location Mean (f)a Mean (f)a Measurements Information Range Range TLD 228 21.21 (224 /224) 86 28.88 (4/4) 19.59(24-/4) Quarterly (17.61-30.62) NNW 0.3 miles (28.16-30.62) 19283) I__II 19.83) TLD Annual 57 84.36 (56 / 56) 86 114.77 (1/1) 78.46(1/1) (74.34-114.77) NNW 0.3 miles 1

a. (f) is the number of positive measurements / total measurements at specified location.

Reference Appendix A, Tables A-1.1, A-1.2 TABLE 5-2 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

COLUMBIA GENERATING STATION DOCKET NO. 50-397 Benton County, Washington Calendar Year 2009 Medium: ISFSI Direct Radiation (TLD) Units: mR/period Location With Highest Annual Control Total Lower Limit Indicator Locations Mean Control Number of Analysis Type Analyses' of Detection Mean (f)a Locations Nonroutine Performed (LLD) Range Location Mean (f)a Mean (f)a Measurements Information Range Range TLD Quarterly 48 135.5 (48 / 48) 137A 208.18 (4 / 4) --- (0/0) 0 T Q (37.9-225.0) NNW 0.24 miles (197.33-224.98) TLD Annual 12 550.7 (12 /12) 137A 865.2(1/1) (0/0) 0 1 (161.4-865.2) NNW 0.24 miles8

a. (f) is the number of positive measurements / total measurements at specified location.

Reference Appendix A, Tables B-1.1, B-1.2 2009 Annual Radiological Environmental Operating Report 5-13 Energy Northwest/Columbia Generating Station

I TABLE 5-2 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

COLUMBIA GENERATING STATION DOCKET NO. 50-397 Benton County, Washington Calendar Year 2009 Medium: Air Particulate/Air Radioiodine Units: pCi/mr Total Lower Limit Indicator Location With Highest Annual Mean Control Locations Number of Total LowerLimi Locations CtLa Analysis Analyses of Detection (f)a a Mean (f)a Nonroutine Type b MeanRange Measurements Performed (LLD) Range Information Range 21 Gross Beta 621 0.01 0.0174(569/569) ENE 1.45 Miles 0.0198(52/52) 0.0155 (52/52) (-0.0009-0.0778) (0.0051-0.0611) (0.0052 - 0.0506) 0 1-131 621 0.07 --- (0/569) --- (0/,52) 0 Cs-134 48 0.05 --- (0/44) --- (0/4) 0 Cs-137 48 0.06 --- (0/44) --- (0/4) 0

a. (f) is the number of positive measurements / total measurements at specified location.
b. These are the ODCM specified LLDs, actual method LLDs will be lower. See Table 4-4.

Reference Appendix A, Tables A-2.1, A-2.2, Tables A-3.1, A-3.2, and Tables A-4.1, A-4.2. U I i I I I I I Ii "i I I I I 2009 Annual Radiological Environmental Operating Report 5-14 Energy Northwest/Columbia Generating Station

TABLE 5-2 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

COLUMBIA GENERATING STATION DOCKET NO. 50-397 Benton County, Washington Calendar Year 2009 Medium: Water-River/Drinking Units: pCi/L Indicator Location With Highest Annual Mean Total Lower Limit Locaton Control Locations Number of AnalysisLocations Type Analyses of Detection Mean (f)a Nonroutine Type Performed (LLD) c Mean (f)a Location Mean (f)a Range Measurements Range Information Range 29 0.732(1/12) --- (0/12) Gross Beta 24' 4.0 ---(1 / 24 )(b) SSE 11.76 (-0.864-2.32) 0 miles (-0.864-2.32) H-3 8 2000 (0 / 8 )(b) --- (0/4) 0 Mn-54 24 15 --- (0 / 2 4) (b) --- (0/ 12) 0 Fe-59 24 30 --- (0/24) (b) -- (0/12) 0 Co-58 24 15 --- (0 / 2 4 ) (b) ---(0/ 12) 0 Co-60 24 15 --- (0 / 2 4 ) (b) --- (0/12) 0 Zn-65 24 30 --- (0 / 2 4 ) (b) --- (0/12) 0 Zr/Nb-95 24 15 --- (0 / 24) (b) (0/12) 0 Cs-134 24 15 --- (0/ 2 4 )(b) --- (0/12) 0 Cs-137 24 18 --- (0 / 2 4 ) (b) --- (0/12) 0 Ba/La-140 24 15 --- (0 / 2 4 ) (b) --- (0/12) 0

a.

(f) is the number of positive measurements / total measurements at specified location.

b.

This includes the control sample for this group; the control (Station 26) is also a drinking water sample.

c.

These are the ODCM specified LLDs, actual method LLDs will be lower. See Table 4-4. Reference Appendix A, Tables A-5.1,A-5.2, Tables A-6.1, A-6.2, and Tables A-7.1, A-7.2 2009 Annuat Radiological Environmental Operating Report 5-15 Energy Northwest/Columbia Generating Station 2009 Annual Radiological Environmental Operating Report 5-15 Energy Northwest/Columbia Generating Station

TABLE 5-2 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

COLUMBIA GENERATING STATION DOCKET NO. 50-397 Benton County, Washington Calendar Year 2009 Medium: Water-Discharge Units: pCi/L Indicator Location With Highest Annual Mean Total Lower Limit Control Locations Number of Analyses ofeLocationst y Mean (f) a Location Mean (f)a Mean (f)a Nonroutine Performed (LLD) Range Information Range Rang! Measurements Gross Beta 12 4.0 3.69(9/12) 27 3.69 (9/12) ---o(0/ b) 0 (0.937-8.66) E 3.2 miles (0.937-8.66) H-3 4 2000 ---(0/4) --- (0/0) 0 Mn-54 12 15 --- (0/12) --- (0/0) 0 Fe-59 12 30 --- (0/12) --- (0/0) 0 Co-58 12 15 --- (0/12) --- (0 0) 0 Co-60 12 15 --- (0/12) --- (0/0) 0 Zn-65 12 30 --- (0/ 12) --- (0/!0) 0 Zr/Nb-95 12 15 --- (0/ 12) --- (0/0) 0 Cs-134 12 15 --- (0/12) --- (0/0) 0 Cs-137 12 18 --- (0/ 12) --- (0/10) 0 BaILa-140 12 15 --- (0/12) (0/b0) 0.

a. (f) is the number of positive measurements / total measurements at specified location.
b. These are the ODCM specified LLDs, actual method LLDs will be lower. See Table 4-4.

Reference Appendix A, Tables A-5.1,A-5.2, Tables A-6.1, A-6.2, and Tables A-7.1, A-7.2 2009 Annual Radiological Environmental Operating Report 5-16 Energy Northwest/Columbia Generating Station

TABLE 5-2 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

COLUMBIA GENERATING STATION DOCkET NO. 50-397 Benton County, Washington Calendar Year 2009 Medium: Water-Deep Ground Units: pCi/L Indicator Location With Highest Annual Mean Total Lower Limit Control Locations Number of Analysis Analyses of Detection Locations Mean (f)a Nonroutine Type Performed (LLD)b Mean (f)a

Location, Mean (f)a Measure Range Information Range Range Measurements H-3 12 2000

--- (0/12) --- (0/0) 0 Mn-54 12 15 --- (0/ 12) --- (0/0) 0 Fe-59 12 30 --- (0 / 12) ---(0/0) 0 Co-58 12 15 --- (0/ 12) --- (0/0) 0 Co-60 12 15 --- (0/12) --- (0/0) 0 Zn-65 12 30 --- (0/12) --- (0/0) 0 Zr/Nb-95 12 15 --- (0/12) ---(0 / 0) 0 Cs-134 12 15 --- (0/12) ---(0/0) 0 Cs-137 12 18 --- (0/12) --- (0/0) 0 Ba/La-140 12 15 --- (0/12) (0/0) 0

a. (f) is the number of positive measurements / total measurements at specified location.
b. These are the ODCM specified LLDs, actual method LLDs will be lower. See Table 4-4.

Reference Appendix A, Tables A-6.1, A-6.2, and Tables A-7.1, A-7.2 2009 Annual Radiological Environmental Operating Report 5-17 Energy NorthwestlColumbia Generating Station 2009 Annual Radiological Environmental Operating Report 5-17 Energy Northwest/Columbia Generating Station

TABLE 5-2 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

COLUMBIA GENERATING STATION DOCKET NO. 50-397 Benton County, Washington Calendar Year 2009 Medium: Water-Shallow Ground Units: pCi/L Indiator Location With Highest Annual Mean Total Lower Limit Locator Control Locations Number of Analysis Analyses of Detection Mean (fns Nonroutine Ty Performed (LLD) b Mean (f)a Location Mean (f)a Nonroutine Range Information Range Range Measurements 22 6.9(20/22) MW-3 13.0(2/2) --- (0/0) 22 Gross Alpha (0.1-17.2) SSW 0.3 miles (12.2-13.7) Gross Beta 22 4.0 6.5 (19/22) MW-5 15.0(2/2) --- (0/0) 22 (0.6-16.5) SW 0.43 miles (13.4-16.5) H-3 44 2000 3600 (41 / 44) MW-5 16,800 (4 / 4) --- (0/0) 0 (16-17,000) SW 0.43 miles (16,600-17,000) Mn-54 44 15 --- (0/44). --- (0/0) 0 Fe-59 44 30 --- (0/44) --- (0/0) 0 Co-58 44 15 -- (0 / 44) --- (0/0) 0 Co-60 44 15 --- (0/44) --- (0/0) 0 Zn-65 44 30 --- (0/44) --- (0/0) 0 Zr/Nb-95 44 15 --- (0/44) --- (0/0) 0 Cs-134 44 15 --- (0/44) --- (0/0) 0 Cs-137 44 18 --- (0/44), --- (0/0) 0 Ba/La-140 44 15 --- (0/44) --- (0/0) 0 Fe-55 22 ---(0/22) --- (0/0) 22 Ni-63 22 --- (0/22) --- (0/0) 22 Sr-90 22 (0/22), --- (0/10) 22

a. (f) is the number of positive measurements / total measurements at specified location.
b. These are the ODCM specified LLDs, actual method LLDs will be lower. See Table 4-4.

Reference Appendix A, Tables B-9.1, B-10.1, B-1 0.2, B-1 1.1, and B-12.1. 2009 Annual Radiological Environmental Operating Report 5-18 Energy Nor-thwest/Columbia Generating Station

TABLE 5-2 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

COLUMBIA GENERATING STATION DOCKET NO. 50-397 Benton County, Washington Calendar Year 2009 Medium: River Sediment Units: pCi/kg Indicator Location With Highest Annual Mean Total Lower Limit Control Locations Number of Analysis Analyses of Detection Loan Mean (f)a Nonroutine Type Performed (LLD) b Mean (f)a Location Mean (f)a Range Measurements Range Information Range Cs-134 4 150 --- (0/2) --- (0/2) 0 Cs-137 4 180 158 (2/2) 34 150 (2/2) 44.3(1 /2) 0 (145-171) ESE 3.32 Miles (145-171) (36.8-51.8) Co-60 4 --- (0/2) (0/2) 0

a. (f) is the number of positive measurements / total measurements at specified location.
b. These are the ODCM specified LLDs, actual method LLDs will be lower. See Table 4-4.

Reference Appendix A, Tables A-9.1, A-9.2. 2009 Annual Radiological Environmental Operating Report 5-19 Energy Northwest/Columbia Generating Station

I TABLE 5-2 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

COLUMBIA GENERATING STATION DOCKET NO. 50-397 Benton County, Washington Calender Year 2009 Medium: Roots Units: pCi/kg Indicator Location With Highest Annual Mean Total Lower Limit Control Locations Number of Analysis Analyses of Detection Locations Mean (f)a Nonroutine Type Performed (LLD) b Mean (f)a Location Mean (f)a Range Measurements Range Information Range 1-131 8 60 --- (0/4) --- (0/4) 0 Cs-134 8 60 --- (0/4) --- (0/4) 0 Cs-137 8 80 --- (0/4) --- (0/4) 0

a. (f) is the number of positive measurements / total measurements at specified location.
b. These are the ODCM specified LLDs, actual method LLDs will be lower. See Table 4-4.

Reference Appendix A, Tables A-15.1, A-15.2. TABLE 5-2 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

COLUMBIA GENERATING STATION DOCKET NO. 50-397 Benton County, Washington Calendar Year 2009 Medium: Fruits Units: pCi/kg Indictor ocation With Highest Annual Mean Total Lower Limit Ldcaton: Control Locations Number of Analysis Analyses of Detection Mean (f)a Nonroutine Type Performed (LLD) b Mean (f)a Location Mean (f)aan nt Range Information Range Range Measurements 1-131 9 60 --- (0/5) ---(014) 0 Cs-134 9 60 --- (0/5), --- (0/4) 0 Cs-137 9 80 --- (0/5) ---(0/4) 0

a. (f) is the number of positive measurements / total measurements at specified location.
b. These are the ODCM specified LLDs, actual method LLDs will be lower. See Table 4-4.

Reference Appendix A, Table A-16.1, A-16.2. I I I I I I I ,I I I I I I I I 2009 Annual Radiological Environmental Operating Report 5-20 Energy Northwest/Columbia Generating Station

TABLE 5-2 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

COLUMBIA GENERATING STATION DOCKET NO. 50-397 Benton County, Washington Calendar Year 2009 Medium: Vegetables Units: pCi/kg Total Lower Limit Indicator Location With Highest Annual Mean Anlss Ttl LwrLmt Locations Control Locations Number of Analysis Analyses of Detection Location Mean (f)a Nonroutine T p eromdeLD b Mean (f)a Location Mean (f)3aorotn Performed (LLD) Range Information Range Range Measurements 1-131 16 60 --- (0/10) ---(0/6) 0 Cs-134 16 60 --- (0/10) (0/6) 0 Cs-137 16 80 --- (0/10) ---(0/6) 0

a. (f) is the number of positive measurements / total measurements at specified location.
b. These are the ODCM specified LLDs, actual method LLDs will be lower. See Table 4-4.

Reference Appendix A, Table A-17.1, A-17.2. TABLE 5-2 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

COLUMBIA GENERATING STATION DOCKET NO. 50-397 Benton County, Washington Calendar Year 2009 Medium: Fish Units: pCi/kg Total Lower Limit Indicator Location With Highest Annual Mean Control Locations Number of Analysis Analyses of Detection Locations Mean (f)a Nonroutine Type Performed (LLD) b Mean (f)a Location Mean (f)a Range Measurements Range Information Range Mn-54 6 130 --- (0/3) --- (0/3) 0 Fe-59 6 260 --- (0/3) --- (0/3) 0 Co-58 6 130 --- (0/3) --- (0/3) 0 Co-60 6 130 --- (0/3) --- (0/3) 0 Zn-65 6 260 --- (0/3) --- (0/3) 0 Cs-134 6 130 --- (0/3) ---(0/3) 0 Cs-137 6 150 --- (0/3) --- (0/3) 0

a. (f) is the number of positive measurements / total measurements at specified location.
b. These are the ODCM specified LLDs, actual method LLDs will be lower. See Table 4-4.

Reference Appendix A, Table A-10.1, A-10.2. 2009 Annual Radiological Environmental Operating Report 5-21 Energy Northwest/Columbia Generating Station

TABLE 5-2 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

COLUMBIA GENERATING STATION DOCKETý NO. 50-397 Benton County, Washington Calendar Year 2009 Medium: Milk Units: pCi/L Indicator Location With Highest Annual Mean Total Lower Limit Control Locations Number of Analysis Locations (f)a Analyses of Detection Locnateao Nonroutine Type Performed (LLD) b Mean (f)a Location Mean (f)a Range Measurements Range Information Range 1-131 36 1.0 --- (0/18) --- (0/18) 0 Cs-134 36 15 --- (0/18) (0/18) 0 Cs-137 36 18 --- (0/18) --- (0/18) 0 Ba/La-140 36 15 --- (0/18) (0/18) 0

a. (f) is the number of positive measurements / total measurements at specified location.
b. These are the ODCM specified LLDs, actual method LLDs will be lower. See Table 4-4.

Reference Appendix A, Tables A-1 1.1, A-1 1.2, Tables A-1 2.1, A-1 2.2. II i I I I, I' i I I I I UI I I I 2009 Annual Radiological Environmental Operating Report 5-22 Energy Northwest/Columbia Generating Station

TABLE 5-3 QUARTERLY TLD DATA

SUMMARY

WITH COMPARISON TO PREOPERATIONAL AND OPERATIONAL PERIODS Results in mR/Standard Quarter Pre-Operational Operational to 2008 2009 Operational Station Min Max Std Dev MEAN Min Max Std Dev MEAN min max Std Dev MEAN 1 2 3 4 5 6 19.16 23.73 17.34 22.81 18.25 21.90 15.51 23.73 18.25 22.81 18.25 21.90 2.07 2.09 1.46 2.65 1.74 1.50 21.90 21.10 20.42 19.96 20.76 20.19 18.25 27.38 16.43 25.55 16.43 24.64 14.60 22.81 16.43 23.73 16.43 23.73 1.77 1.64 1.77 1.76 1.75 1.63 22.21 21.73 21.01 19.61 20.13 20.31 21.00 22.08 19.32 21.82 19.13 20.05 17.61 20.59 18.45 19.80 18.68 19.82 0.51 1.16 0.40 1.43 0.59 0.50 21.38 20.84 19.59 18.96 19.20 19.15 7 19.16 22.81 8 21.90 25.55 9 15.51 21.90 10 19.16 22.81 11 19.16 22.81 12 20.99 24.64 13 19.16 22.81 14 19.16 24.64 15 20.99 25.55 16 20.08 23.73 17 19.16 23.73 18 20.08 23.73 19 20.08 23.73 20 19.16 23.73 21 19.16 21.90 22 19.16 23.73 23 20.08 23.73 24 20.99 23.73 25 20.99 24.64 40 17.34 21.90 41 20.08 25.55 42 20.08 23.73 43 20.99 24.64 44 19.16 22.81 45 19.16 22.81 46 22.81 28.29 47 17.34 20.99 49 21.90 21.90 50 20.08 20.08 51 19.16 21.90 53 24.64 24.64 54 23.73 23.73 55 20.99 20.99 56 21.90 21.90 58 1.69 21.33 16.43 24.64 1.81 21.21 18.78 20.37 1.50 23.84 2.00 19.85 1.38 20.99 1.38 21.44 1.60 23.04 1.54 21.44 2.07 21.90 1.37 23.15 1.52 22.13 1.62 22.81 1.27 22.13 1.24 22.01 1.76 21.44 1.25 20.68 1.58 22.01 1.49 21.60 1.09 21.90 1.46 23.15 1.70 19.94 2.00 23.73 1.61 22.36 1.49 23.12 1.34 21.12 1.37 21.25 2.10 26.10 1.73 19.85 21.90 20.08 1.18 20.53 24.64 23.73 20.99 21.90 15.51 27.38 16.43 23.73 16.43 24.64 16.43 24.64 18.25 26.46 17.34 27.38 17.34 25.55 17.34 27.38 16.43 26.46 17.34 26.46 16.43 25.55 17.34 25.55 17.34 25.55 15.51 23.73 16.43 25.55 17.34 25.55 17.34 50.50 17.34 27.38 15.51 24.64 17.34 27.38 17.34 26.46 16.43 27.38 15.51 24.64 16.43 25.55 19.16 31.94 15.51 26.28 16.43 25.55 16.43 26.46 16.43 24.64 18.25 29.57 18.18 26.46 16.43 25.55 16.43 25.55 2.08 1.79 1.73 1.56 1.79 1.88 1.59 1.78 1.88 1.69 1.76 1.65 1.72 1.50 1.56 1.71 3.36 1.99 1.80 2.11 2.01 2.25 2.01 1.86 2.23 1.80 1.62 1.82 1.71 2.07 2.04 1.57 1.83 23.34 19.74 21.07 21.58 23.22 21.46 21.57 23.15 22.09 22.58 22.06 22.26 21.89 20.41 21.84 21.25 22.29 22.88 20.22 22.60 22.17 22.68 20.94 21.33 26.61 20.32 21.98 21.73 21.19 23.61 22.21 21.50 21.92 20.95 22.84 19.24 19.83 18.84 21.64 20.12 22.88 21.42 23.97 19.66 21.07 20.56 21.48 22.32 23.41 20.11 21.64 21.45 23.15 20.71 22.55 19.98 22.75 19.74 22.10 19.37 20.90 20.57 22.57 19.33 20.68 18.28 23.85 19.16 23.53 17.66 19.99 20.23 22.46 20.42 21.71 21.02 23.10 18.59 20.82 19.07 21.25 22.82 27.77 18.70 20.97 20.52 23.75 19.30 22.02 19.82 20.84 21.19 23.05 18.47 22.19 19.91 22.69 19.92 22.27 0.70 19.79 0.85 22.20 0.25 19.59 1.24 20.12 1.18 21.31 1.25 22.61 0.62 20.17 0.40 20.92 0.49 22.71 0.66 20.82 0.78 22.36 0.82 21.35 1.14 21.45 1.08 20.92 0.68 19.99 0.86 21.59 0.55 19.97 2.40 20.40 1.81 21.41 0.98 18.94 1.15 21.34 0.59 20.85 0.85 22.08 1.09 19.53 0.99 20.22 2.06 25.49 1.02 19.50 1.40 22.24 1.37 20.82 0.46 20.49 0.78 22.09 1.78 20.30 1.27 21.02 1.08 20.95 0.70 19.22 18.52 19.93 2009 Annual Radiological Environmental Operating Report 5-23 Energy Northwest/Columbia Generating Station 2009 Annual Radiological Environmental Operating Report 5-23 Energy North west/Col umbia Generating Station

TABLE 5-3 (cont) QUARTERLY TLD DATA

SUMMARY

WITH COMPARISON TO PREOPERATIONAL AND OPERATIONAL PERIODS Results in mR/Standard Quarter Pre-Operational Operational to 2008 2009 Operational Station Min Max Std Dev MEAN Min Max Std Dev MEAN min max Std Dev MEAN I I I 65 71(1S) 72(2S) 73(3S) 74(4S) 75(5S) 76(6S) 77(7S) 78(8S) 79(9S) 80(10S) 81(11S) 82(12S) 83(13S) 84(14S) 85(15S) 86(16S) 87 88 89 90 119B 119Ctrl 120East 121 (ISFSI) 122 (ISFSI) 123 (ISFSI) 124 (ISFSI) 125 (ISFSI) 126 (ISFSI) 127 (ISFSI) 128 (ISFSI) 129 (ISFSI) 136A (ISFSI) 137A (ISFSI) 138A (ISFSI) 150 (Site 1) 151 (Site 4) 20.08 22.81 21.90 23.73 20.08 21.90 23.73 24.64 19.16 21.90 20.99 22.81 21.90 23.73 21.90 23.73 22.81 23.73 20.99 22.81 20.08 23.73 21.90 24.64 21.90 23.73 20.99 22.81 21.90 24.64 21.90 23.73 1.58 0.91 0.91 0.53 1.39 0.91 0.91 1.05 0.53 0.91 1.90 1.39 0.91 1.05 1.58 0.91 21.90 22.81 20.99 24.03 20.38 21.90 22.81 22.51 23.12 21.90' 22.20 23.42 22.81 22.20 23.73 22.81 17.73 22.72 18.25 30.39 18.25 29.65 16.43 24.64 18.25 28.29 15.51 26.46 17.34 26.46 17.34 25.55 17.34 25.55 17.34 25.55 16.43 25.55 17.34 25.55 17.34 26.46 17.34 26.46 16.43 27.17 17.34 27.83 18.25 31.28 1.32 19.96 2.52 25.30 2.04 24.45 1.63 21.33 1.97 23.49 1.95 22.33 1.73 22.11 1.68 22.11 1.64 21.60 1.71 21.97 1.84 21.11 1.60 21.60 1.64 22.48 1.95 22.40 1.83 22.41 1.96 23.19 2.56 25.79 18.79 20.54 23.88 27.40 22.00 24.89 19.85 21.32 21.31 23.14 19.72 23.17 19.66 21.96 20.17 21.95 19.93 22.32 20.49 21.83 19.25 20.43 20.73 21.73 21.20 22.54 20.27 22.13 20.46 21.93 20.95 23.60 28.1,6 30.62 22.78 32.67 24.53 30.68 23.22 29.38 18.37 19.50 20.73 23.70 20.87 22.40 21.34 23.52 49.51 97.13 37.93 40.66 139.93 154.80 170.02 181.62 120.62 128.56 123.44 137.51 89.23 96.76 156.13 177.42 119.39 131.18 180.18 199.12 0.87 19.69 1.71 24.86 1.19 23.33 0.64 20.73 0.85 22.23 1.47 21.49 1.06 21.22 0.75 21.16 1.24 21.02 0.56 21.25 0.51 19.97 0.49 21.00 0.55 21.90 0.80 21.36 0.66 20.98 1.19 21.84 1.17 28.88 4.22 26.86 2.97 27.60 2.71 26.07 0.50 18.76 1.32 21.94 0.66 21.74 0.95 22.15 21.88 73.84 1.28 39.43 6.66 145.20 4.91 176.35 3.46 123.97 6.40 128.16 3.56 91.51 9.92 162.85 5.46 123.05 8.22 187.42 I' I 19.36 25.64 1.50 22.19 19.53 26.55 1.48 21.79 19.78 31.12 2.02 22.47 20.81 130.27 23.59 77.47 19.62 42.49 7.18 28.74 24.99 160.33 46.15 109.93 26.89 201.05 59.76 139.61 26.46 135.52 35.47 97.41 26.00 145.68 28.38 68.39 28.97 102.08 17.58 -56.01 25.64 187.25 41.78 74.27 30.16 138.08 28.77 62.27 28.99 205.64 48.59 65.20 29.47 238.74 56.27 71.24 28.28 196.68 44.01 62.33 11.92 18.69 1.75 17.33 17.02 32.44 4.31 18.88 197.33 224.98 11.80 208.18 158.70 181.04 10.37 165.79 18.05 19.63 0.68 19.02 18.98 19.87 0.38 19.45 I I I I U I I I U I Table 5-3 Notes: The preoperational mean is from 1982-1983 data. Station 65 was added in 1997. Stations 1198, 11 9Ctrl, and 120 were added in 1995: Stations 121 and 122 were added in 1998 for the ISFSI. Stations 123-129 and 136A-138A were added in the 2nd quarter of 2002. Stations Site 1 and Site 4 were added in 2006. Stations 58 and 87 to 90 were added in 2009 to monitor remediation work at DOE 618-11 burial site. 2009 Annual Radiological Environmental Operating Report 5-24 Energy Northwest/Columbia Generating Station

TABLE 5-4 ANNUAL TLD DATA

SUMMARY

WITH COMPARISON TO PREOPERATIONAL AND OPERATIONAL PERIODS Results in mR per Year Pre-Operational 1984-2008 Operational 2009 Station Min Max Std Dev MEAN Min Max Std Dev MEAN Result 85.37 98.66 83.44 84.53 81.94 85.74 74.46 100.52 81.29 93.62 79.79 83.95 84.28 86.61 94.61 98.62 78.00 81.58 82.02 86.72 83.04 88.26 92.27 94.17 85.41 88.00 84.50 86.25 83.95 94.83 89.61 91.83 85.59 91.47 86.51 97.64 85.41 90.05 79.72 84.24 84.79 88.07 83.55 87.09 85.26 87.97 90.56 95.37 94.90 97.46 83.48 89.53 82.53 86.10 102.42 107.53 9.39 92.02 0.77 83.99 2.68 83.84 18.43 87.49 8.72 87.45 2.94 81.87 1.65 85.45 2.84 96.62 2.53 79.79 3.33 84.37 3.69 85.65 1.34 93.22 1.83 86.71 1.24 85.37 7.69 89.39 1.57 90.72 4.16 88.53 7.87 92.07 85.63 3.28' 87.73 3.20 81.98 2.32 86.43 2.50 85.32 1.91 86.61 3.41 92.97 76.54 1.81 96.18 85.81 88.22 4.28 86.51 2.53 84.32 3.61 104.97 80.45 73.00 102.20 7.30 73.00 98.19 6.32 70.99 94.17 6.61 65.70 87.24 5.68 68.62 88.33 5.60 69.35 90.52 6.14 71.58 97.09 6.27 80.34 108.04 7.60 68.99 91.98 5.79 69.35 93.81 5.17 73.00 99.28 6.65 80.30 102.57 5.49 76.65 97.46 5.80 69.35 97.09 6.52 76.65 104.03 7.37 76.65 101.47 6.60 76.65 101.84 6.48 76.65 101.47 6.18 76.65 104.03 6.07 74.78 101.84 6.66 69.35 91.25 5.93 74.98 97.09 6.37 72.65 94.90 6.44 74.28 100.01 7.17 76.65 104.03 7.46 68.08 91.25 6.20 75.19 102.20 8.15 75.92 104.03 7.58 71.18 107.68 9.56 71.91 94.17 6.63 72.64 96.36 5.89 94.90 123.37 7.59 69.35 95.27 6.61 76.65 100.74 6.24 73.00 100.01 7.34 72.11 97.46 6.73 77.75 104.03 6.91 75.83 100.38 7.23 72.97 96.36 6.10 71.18 101.47 6.70 71.25 86.51 4.30 83.55 82.23 78.30 74.74 75.89 76.27 80.73 89.97 75.59 79.97 81.91 87.75 82.78 81.27 88.04 84.59 85.65 85.47 84.65 83.63 76.99 82.18 80.06 82.44 87.53 75.45 85.17 83.39 84.19 79.34 80.61 102.80 78.17 82.84 81.28 80.17 89.84 84.74 80.26 83.99 75.49 83.03 82.31 76.67 78.66 77.48 76.16 76.36 84.52 78.46 81.62 81.52 88.84 82.12 84.89 89.56 88.49 84.82 86.97 85.77 85.34 79.73 80.40 78.73 81.32 91.11 74.34 83.40 81.72 84.46 80.54 79.23 103.68 79.51 83.54 79.79 83.04 85.90 84.41 81.83 83.72 76.47 58 65 2009 Annual Radiological Environmental Operating Report 5-25 Energy NorthwestlColumbia Generating Station 2009 Annual Radiological Environmental Operating Report 5-25 Energy Northwest/Columbia Generating Station

TABLE 5-4 (cont) ANNUAL TLD DATA

SUMMARY

WITH COMPARISON TO PREOPERATIONAL AND OPERATIONAL PERIODS Results in mR per Year Pre-Operational 1984-2008 Operational 2009 Station Min Max Std Dev MEAN Min Max Std Dev MEAN Result 71(1S) 72(2S) 73(3S) 74(4S) 75(5S) 76(6S) 77(7S) 78(8S) 79(9S) 80(10S) 81(11S) 82(12S) 83(13S) 84(14S) 85(15S) 86(16S) 87 88.04 91.54 83.69 88.99 86.32 88.26 89.90 89.94 91.98 85.30 82.67 89.79 91.10 84.06 92.13 87.82 83.95 112.06 83.95 110.96 73.00 94.90 80.30 106.22 73.00 100.74 76.65 101.47 73.00 99.28 73.00 97.71 73.00 101.11 69.42 97.09 72.19 96.36 74.83 101.47 76.65 99.65 76.03 99.28 80.30 105.85 87.60 119.82 7.37 6.74 5.90 6.23 6.53 5.49 5.98 6.39 6.24 6.92 6.74 6.90 6.69 6.31 6.00 8.75 97.42 93.72 80.37 89.80 84.49 84.55 83.88 82.63 83.01 80.52 80.89 84.88 86.18 84.68 89.71 99.91 100.20 93.64 80.70 91.36 82.89 85.55 83.99 82.33 85.12 79.56 84.36 84.93 85.61 85.10 92.15 114.77 88 89 90 119B 119Ctrl 120East 121 (ISFSI) 122 (ISFSI) 123 (ISFSI) 124 (ISFSI) 125 (ISFSI) 126 (ISFSI) 127 (ISFSI) 128 (ISFSI) 129 (ISFSI) 136A (ISFSI) 137A (ISFSI) 138A (ISFSI) 150 (Site 1) 151 (Site 4) 75.92 107.68 8.97 82.81 77.75 101.84 7.10 85.34 78.11 112.79 10.09 87.66 177.76 377.80 69.63 304.24 76.29 164.53 32.53 112.11 126.22 627.95 198.77 443.62 128.66 714.20 242.67 529.41 119.59 520.11 154.33 383.15 123.06 482.43 112.35 269.49 120.60 350.83 71.24 220.57 112.96 596.87 156.07 288.34 121.78 463.59 110.29 240.09 119.31 637.58 174.88 256.28 124.36 734.29 207.62 281.01 122.70 577.56 157.38 238.63 68.59 73.97 2.77 70.91 46.44 68.26 12.54 60.92 107.22 109.73 112.67 77.28 81.09 85.21 83.36 297.94 161.43 593.21 692.52 498.64 524.95 373.82 667.70 480.98 763.67 865.22 688.04 71.95 73.33 I i I I I I I' I I 3 I I I U I I I I Table 5-4 Notes: The preoperational period was from 1982-1983. Only one annual preoperational exchange was made at some locations. Stations 49-56 were first monitored during the Fourth Quarter of 1983. Stations 65 was added in 1997. Stations 1198, 119Ctrl, and 120 were added in 1995. Stations 121 and 122 were added in 1998 to gather baseline data for the ISFS1. Stations 123-129 and 136A-138A were added in the 2nd Quarter of 2002. Stations Site 1 and 4 were added in 2006. Stations 58 and 87 to 90 were added in 2008 to monitor remediation work at DOE 618-11 burial site. 2009 Annual Radiological Environmental Operating Report 5-26 Energy Northwest/Columbia Generating Station

6.0 QUALITY ASSURANCE AND QUALITY CONTROL

6.0 OUALITY ASSURANCE AND OUALITY CONTROL The REMP is designed to meet the quality assurance (QA) and quality control (QC) criteria of the NRC Regulatory Guide 4.15(4) and 10 CFR 50 Appendix B(10). The contractors used for sample analysis, Energy Northwest Environmental Services and Battelle PNNL, maintain quality control programs to ensure that analytical results are accurate, precise, and defensible. The following sections summarize the quality assurance and quality control aspects of the TLD, sample collection, and sample analysis components of the REMP. 6.1 Quality Control for the Energy Northwest Environmental TLD Program The Quality Control program for the Energy Northwest REMP TLDs covers the preparation, transportation, deployment, collection, storage, processing, and evaluation. From the time the TLDs are annealed to the time they are placed in the field, they are stored and transported with control TLDs. Two sets of control TLDs are used, the building controls and the transportation (trip) controls. The building controls monitor the exposure that the TLDs receive while being transported to and from the TLD vendor and while in storage awaiting deployment and analysis. The trip controls accompany the field TLD set while they are being transported to and from the vendor and also while they are being deployed and collected in the field. The building controls and trip controls are stored in a low background lead shield while the field TLDs are deployed, If the trip control results are greater than the building control results, the difference between the two is subtracted from the field dosimeters to account for exposure during transit. Reader QC dosimeters are prepared by Battelle at the Pacific Northwest National Laboratory and serve as indicators that the reader calibration is satisfactory and that the TLDs were processed correctly.. These TLDs are annealed and then given a known exposure (typically 100 mR) to a cesium-137 source. The number of QC dosimeters used during each processing is generally 10% of the number of field dosimeters. Evaluation of the 2009 reader QC dosimeter results indicated satisfactory agreement for all periods. The average reader QC results are presented in Table 6-1. TLDs designated as spikes are prepared by the Energy Northwest Radiation Protection Department by exposing the TLDs to a calibrated source to produce a known exposure. The spiked dosimeters are submitted and processed with the field dosimeters to further verify the accuracy and precision of the environmental TLD results. Quarterly spikes receive a target exposure of 22 mR and annual spikes receive a target exposure of 88 mR. Additional spiked TLDs were prepared in the I1t and 2nd quarters to test the calibrated source mechanism at different exposure times and distances. Evaluation of the 2009 spiked dosimeter results indicated satisfactory agreement for all periods. Spiked TLD results are presented in Table 6-1. 6.2 Quality Control for the Environmental Sample Program Quality control for the environmental sample program encompasses both the sample collection and sample analysis processes. Results are reviewed for correctness, reasonableness, and data entry errors. Sample results that are suspect are normally investigated. A crosscheck program utilizing blind samples supplied by an outside vendor is maintained for all the sample media routinely analyzed. 2009 Annual Radiological Environmental Operating Report 6-1 Energy Northwest/Columbia Generating Station

I I 6.2.1 Sample Collection Quality Control Duplicate samples are collected and submitted for analysis when practical. The duplicate samples i are used to assess the repeatability of the sample collection process and the precision of the analytical method. 6.2.2 Laboratory Instruments Quality Control Analytical Balances - Analytical balances used in the laboratory for sample preparations are calibrated every six months. Performance checks are performed prior to use and span the range of I intended use. Performance check results are documented on the sample preparation forms and are kept with the analytical results. i Analytical Instruments - Analytical instruments used for determining radioactive emissions in samples are calibrated for efficiency annually using standard reference material traceable to the National Institute of Standards and Technology (NIST). Below is a summary of the routine QC B practices for the different analytical instruments.

  • Gas-flow Proportional Counter: QC and background checks are performed daily when in 3

use. Control charts are maintained with two and three-sigma limits specified; the checks must fall within the two-sigma warning limits prior to use. Mid batch and end of batch performance checks are normally performed. I

  • Gamma Spectrometers: Checked daily for efficiency, energy per channel relationship, peak resolution, and background when in use. The checks are performed and plotted for both a low and high energy peak. Efficiency checks are held within two-sigma control limits. Long duration background checks are performed periodically.
  • Liquid Scintillation Counter: Background and performance checks are performed daily when in use. A QC check in the same matrix as the samples is performed and trended. A I

low level check standard is analyzed with each batch of samples analyzed. 6.2.3 Sample Batch Quality Control I Sample batch analysis is normally performed with sample blanks and known-addition samples (or spiked samples) included. The type of known addition sample used is dictated by the sample media being analyzed, the primary analytes of interest, and the method being used. The following is a summary of sample batch QC activities. i Iodine-131 Cartridges - At least one known-addition sample was analyzed with each batch. In most cases, a charcoal cartridge of the same type used for sample collection but spiked with Ba-133 is used. The 356 keV peak of Ba-133 serves as a proxy for the 364 keV peak of 1-131. Gross Beta Filters - At least one unused blank air particulate filter and at least one known-addition air particulate filter was analyzed with each batch. i Aqueous Samples - In most cases, samples collected from the control locations were analyzed as blanks. A known-addition sample was analyzed with each batch of samples. 3 2009 Annual Radiological Environmental Operating Report 6-2 Energy Northwest/Coiu mbia Generating Station I

Gross Alpha/Beta in Water - Blank Samples were prepared from reagent grade water and analyzed with each batch of samples. One known addition sample and one replicate sample is normally analyzed with each batch. Tritium in Water - A blank and a low level known addition sample are typically analyzed with each batch. A replicate sample was prepared and analyzed inside of each batch in most cases. 6.3 Laboratory Intercomparison Program Participation and Results Participation in cross check intercomparison studies is mandatory for laboratories performing analyses of CGS REMP samples. Intercomparison studies provide a consistent and effective means to evaluate the accuracy and precision of analyses performed by a laboratory. Study results should fall within specified control limits, results that fall outside the control limits should be investigated and corrective action taken. The Energy Northwest Environmental Services Laboratory participated in both RAD and MRAD proficiency testing studies provided by Environmental Resource Associates (ERA) during 2009. The Laboratories intercomparision program was further supplemented by additional cross check media provided by Analytics, Inc. The Laboratories intercomparison program results for 2009 are shown in Table 6-2; results for all media and analytes tested were acceptable. Participation in the ERA and Analytics studies serves to meet the intercomparision program requirements specified in the ODCM. The Laboratory did not participate in a MAPEP study during 2009. In addition to the studies noted above, the CGS REMP maintains a split sample program with the State of Washington Department of Health. Split samples are sent to a State of Washington Lab on a scheduled frequency where they are independently analyzed. This program provides an additional check on the accuracy and precision of the results reported in this document. 2009 Annual Radiological Environmental Operating Report 6-3 Energy Northwest/Columbia Generating Station

TABLE 6-1 2009 ENVIRONMENTAL SPIKED DOSIMETER RESULTS KNOWN REPORTED EXPOSURE EXPOSURE PERIOD SPIKE ID (mR) (mR) BIAS (%) 1 st Quarter 2nd Quarter 3rd Quarter 4th Quarter Annual ENW Spike ENW Spike ENW Spike ENW Spike ENW Spike ENW Spike PNNL Avg. Reader ENW Spike ENW Spike ENW Spike ENW Spike ENW Spike ENW Spike PNNL Avg. Reader ENW Spike ENW Spike ENW Spike PNNL Avg. Reader ENW Spike ENW Spike ENW Spike PNNL Avg. Reader ENW Spike ENW Spike ENW Spike PNNL Avg. Reader 22 22 22 22 22 22 100 22 22 22 22 22 22 100 22 22 22 100 22 22 22 100 88 88 88 100 22.33 21.23 22.55 21.18 22.95 23.42 102.2 21.64 22.70 21.07 23.88 23.70 22.23 102.1 20.52 19.32 20.50 102.3 22.02 23.18 21.08 102.6 88.46 86.17 82.84 103.8 1.5% -3.5% 2.5% -3.7% 4.3% 6.5% 2.2% -1.7% 3.2% -4.2% 8.6% 7.7% 1.0% 2.1% 0.5% -5.4% 0.4% 2.3% 0.1% 5.4% -4.2% 2.6% 0.5% -2.1% -5.9% 3.8% I I I I I I I I I I I I I I I I U I I 2009 Annual Radiological Environmental Operating Report 6-4 Energy Northwest/Columbia Generating Station

TABLE 6-2 ENW REMP PROGRAM CROSS CHECKS PERFORMANCE RESULTS ERA MRAD-10 Results Spring 2009 Reported Assigned Acceptance Performance Standard/Analyte Units Value Value Limits Evaluation Air Filter Radionuclides Americium-241 pCi/Filter 60.2 55.4 32.4-76.0 Acceptable Cesium-1 34 pCi/Filter 852 865 563-1070 Acceptable Cesium-137 pCi/Filter 755 724 544-951 Acceptable Cobalt-60 pCi/Filter 504 490 379 - 612 Acceptable Manganese-54 pCi/Filter <5 0 Acceptable Zinc-65 pCi/Filter 204 185 128-256 Acceptable Air Filter Gross Alpha/Beta Gross Alpha pCi/Filter 77.7 1 63.8 1 33.1-96.0 [Acceptable Gross Beta pCi/Filter 63.3 1 80.7 1 49.7-118 lAcceptable Water Radionuclides Americium-241 pCi/L 125 132 90.4-178 Acceptable Cesium-134 pCi/L 716 790 584-907 Acceptable Cesium-137 pCi/L 914 913 776-1090 Acceptable Cobalt-60 pCi/L 1200 1230 1070-1450 Acceptable Mancianese-54 pCi/L < 8 0 Acceptable Zinc-65 pCi/L 667 631 535 - 786 Acceptable Water Gross Alpha/Beta Gross Alpha pCi/L 64.6 112 49.7 - 166 Acceptable Gross Beta pCi/L 83.1 81.5 47.7 - 120 Acceptable Water Tritium Tritium pCi/L 11659 11800 7680 - 17400 IAcceptable Soil Radionuclides Actinium-228 pCi/kg 1250 1330 860 - 1880 Acceptable Americium-241 pCi/kq 1430 1660 992 - 2130 Acceptable Bismuth-212 pCi/kg 790 1550 406-2310 Acceptable Bismuth-214 pCi/kg 1290 1420 872 - 2050 Acceptable Cesium-134 pCi/kg 4690 5170 3330 - 6220 Acceptable Cesium-137 pCi/kq 4970 4970 3500 - 6460 Acceptable Cobalt-60 pCi/kg 7400 7520 5470 - 10100 Acceptable Lead-212 pCi/kq 1140 1260 820 - 1780 Acceptable Lead-214 pCi/kq 1370 1510 902 - 2260 Acceptable Manganese-54 pCi/kq < 41 0 Acceptable Potassium-40 pCi/kg 10200 11200 8060 - 15100 Acceptable Zinc-65 pCi/kg 2030 1940 1540 - 2600 Acceptable Vegetation Radionuclides Americium-241 pCi/kg 4410 3660 2090 - 5030 Acceptable Cesium-134 pCi/kg 1920 1880 1080 - 2600 Acceptable Cesium-137 pCi/kg 2410 1800 1320 - 2500 Acceptable Cobalt-60 pCi/kg 1890 1710 1160 - 2460 Acceptable Manganese-54 pCi/kg < 45 0 Acceptable Potassium-40 pCi/kg 30700 30800 22300 - 43700 Acceptable Zinc-65 pCi/kg 1070 878 634 - 1200 Acceptable 2009 Annual Radiological Environmental Operating Report 6-5 Energy Northwest/Columbia Generating Station

TABLE 6-2 ENW REMP PROGRAM CROSS CHECKS PERFORMANCE RESULTS ERA MRAD-11 Results Fall 2009 Reported Assigned Acceptance Performance Standard/Analyte Units Value Value Limits Evaluation Air Filter Radionuclides Americium-241 pCi/Filter 76 67.8 39.7 - 93 Acceptable Cesium-134 pCi/Filter 456.4 524 341 - 648 Acceptable Cesium-137 pCi/Filter 468.7 405 304 - 532 Acceptable Cobalt-60 pCi/Filter 740.5 694 537 - 867 Acceptable Manganese-54 pCi/Filter < 9 0 Acceptable Zinc-65 pCi/Filter 621.5 490 339 - 679 Acceptable Air Filter Gross Alpha/Beta Gross Alpha pCi/Filter 62.9: I 56.7 [ 29.4-85.3 Acceptable Gross Beta pCi/Filter 60.1 62.5 38.5-679 Acceptable Water Radionuclides Americium-241 pCi/L 161.3 152 104-205 Acceptable Cesium-134 pCi/L 578.3 653 482 - 750 Acceptable Cesium-137 pCi/L 683.1 690 586 - 827 Acceptable Cobalt-60 pCi/L 813.4 837 729 - 989 Acceptable Manganese-54 pCi/L < 8.5 0 Acceptable Zinc-65 pCi/L 664.6 636 539 - 793 Acceptable Water Gross Alpha/Beta Gross Alpha IpCi/L I55.55 80.0 35.5-1 19 IAcceptable Gross Beta pCi/L 51.7 67.4 39.4-98.9 Acceptable Water Tritium Tritium pCi/L 18189.2 I 18300 111900 - 2700 Acceptable Soil Radionuclides Actinium-228 pCi/kg 1240.3 1380 885 - 1940 Acceptable Americium-241 pCi/kg 1726.6 1790 1070 - 2300 Acceptable Bismuth-212 pCi/kg 965.1 1670 438 - 2500 Acceptable Bismuth-214 pCi/kg 1221.5 1330 816-1910 Acceptable Cesium-134 pCi/kg 2053.9 2320 1490 - 2790 Acceptable Cesium-137 pCi/kg 2039.4 2180 1670 - 2830 Acceptable Cobalt-60 pCi/kg 1922.7 2000 1460 - 2680 Acceptable Lead-212 pCi/kg 1234.4 1360 877 - 1910 Acceptable Lead-214 pCi/kg 1212.3 1310 784-1950 Acceptable Manganese-54 pCi/kg < 54 0 Acceptable Potassium-40 pCi/kg 9812.4 10800 7830 - 14600 Acceptable Zinc-65 pCi/kg 2278.0 2260 1790 - 3030 Acceptable Vegetation Radionuclides Americium-241 pCi/kg 3170 3850 2190 - 5290 Acceptable Cesium-134 pCi/kg 1330 1780 1020 - 2470 Acceptable Cesium-137 pCi/kg 1160 1460 1070 - 2030 Acceptable Cobalt-60 pCi/kg 1730 2170 1470 - 3120 Acceptable Manganese-54 pCi/kg < 50 0 Acceptable Potassium-40 pCi/kg 29500 34400 24700 - 48700 Acceptable Zinc-65 pCi/kg 1190 1300 939 - 1780 Acceptable I I I U I I I I I I I I I I I I 1 I I 2009 Annual Radiological Environmental Operating Report 6-6 Energy Northwest/Columbia Generating Station

TABLE 6-2 ENW REMP PROGRAM CROSS CHECKS PERFORMANCE RESULTS 2009 Analytics Crosscheck Results 1-131 Charcoal Cartridge Acceptance Performance Sample ID Analysis Units Result Ref Value Limits Evaluation E6552-723 1-131 pCi 70.3 79.6 67.7-91.5 Acceptable A 23925-88 1-131 uCi 0.285 0.299 0.254 - 0.344 Acceptable ERA MRAD-77 Results Fall 2009 1-131 in Milk Acceptance Performance Sample ID Analysis Units Result Ref Value Limits Evaluation RAD-77 1-131 pCi 25.2 26.1 21.7-30.8 Acceptable 2009 Annual Radiological Environmental Operating Report 6-7 Energy Northwest/Columbia Generating Station

7.0 REFERENCES

7.0 REFERENCES

1. U.S. Nuclear Regulatory Commission, "Programs For Monitoring Radioactivity in the Environs of Nuclear Power Plants," Regulatory Guide 4.1, Revision 1, April 1975.
2. U.S. Nuclear Regulatory Commission, "Environmental Technical Specifications For Nuclear Power Plants," Regulatory Guide 4.8, December 1975.
3. U.S. Nuclear Regulatory Commission, "An Acceptable Radiological Environmental Monitoring Program," Assessment Branch Technical Position Revision 1, November 1979.
4. U.S. Nuclear Regulatory Commission, "Quality Assurance For Radiological Environmental Monitoring Program (Normal Operations), Effluent Streams and the Environment,"

Regulatory Guide 4.15, Revision 1, February 1979.

5. U.S. Nuclear Regulatory Commission, "Performance, Testing and Procedural Specifications For Thermoluminescence Dosimetry-Environmental Applications," Regulatory Guide 4.13, Revision 1, July 1977.
6. Energy Facility Site Evaluation Council, Resolution No. 260, January 1992.
7. Energy Northwest Nuclear Columbia Generating Station, Operating License NPF-21, "Technical Specifications" Sections 5.5.1 and 5.6.1
8. Columbia Generating Station Offsite Dose Calculation Manual (ODCM).
9. Code of Federal Regulations, Title 10 Part 20, "Standards for Protection against Radiation."
10. Code of Federal Regulations, Title 10 Part 50, "Domestic Licensing of Production and Utilization Facilities."
11. US DOE, 1995, Hanford Site

Background:

Evaluation of Existing Soil Radionuclide Data, DOE/RL-95-55, US Dept. of Energy, Richland, WA.

12. Washington Administrative Code 173-200-040, "Water Quality Standards for Ground Water of the State of Washington - Criteria."
13. Washington Administrative Code 173-201A, "Water Quality Standards for Surface Waters of the State of Washington."
14. Reference number not used.
15. Energy Facility Site Evaluation Council, Resolution No. 300, approved September 10, 2001.
16. Energy Facility Site Evaluation Council, Resolution No. 299, approved August 13, 2001.

2009 Annual Radiological Environmental Operating Report 7-1 Energy Northwest/Columbia Generating Station

17. Energy Northwest, "Columbia Generating Station Final Safety Analysis Report," Section 2.3.1.1.
18. Reference number not used.
19. PNNL, 2009, Hanford Site Environmental Monitoring Report for Calendar Year 2008, PNNL-18427, Pacific Northwest National Laboratory, Richland, WA.
20. PNNL, 2007, Summary of Hydrogeology and Evaluation of Existing Groundwater Monitoring Wells for Outfalls 002 and 003 at the Columbia generating Station, PNWD-3845, Pacific Northwest National Laboratory, Richland, WA.
21. Nuclear Energy Institute, Industry Ground Water Protection Initiative - Final Guidance Document, NEI 07-07, Nuclear Energy Institute, 1776 1 Street N. W., Suite 400, Washington D.C.

I I I I I I I I I I I I I I I I I I I 2009 Annual Radiological Environmental Operating Report 7-2 Energy Northwest/Columbia Generating Station

8.0 ERRATA

8.0 ERRATA No corrections to the Columbia Generating Stations previous Annual Radiological Environmental Monitoring Reports were identified. 2009 Annual Radiological Environmental Operating Report 8-1 Energy NorthwestlColumbia Generating Station 2009 Annual Radiological Environmental Operating Report 8-1 Energy North west/Columbia Generating Station

ENERGY NORTHWEST People Vision. Solutions APPENDIX A 2009 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT COLUMBIA GENERATING STATION DATA TABLES A and B Covers Sample Collection Period Starting January 2009 Through December 2009 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Prepared by: Energy Northwest - Environmental Services Staff Richland, WA

APPENDIX A - TABLE OF CONTENTS TABLE A: ROUTINE RESULTS A-1. 1 2009 Quarterly & Annual TLD Results A-1.2 2009 Quarterly & Annual TLD Results - Summary A-2.1 Gross Beta on Air Particulate Filters A-2.2 Gross Beta on Air Particulate Filters - Summary A-3.1 Gamma Spectrometry Results of Air Particulate Filters A-3.2 Gamma Spectrometry Results of Air Particulate Filters - Summary A-4.1 Gamma Spectrometry Results of 1-131 on Charcoal Filters A-4.2 Gamma Spectrometry Results of 1-131 on Charcoal Filters - Summary A-5.1 Gross Beta in Water A-5.2 Gross Beta in Water - Summary A-6.1 Tritium in Water A-6.2 Tritium in Water - Summary A-7.1 Gamma Spectrometry Results of Water A-7.2 Gamma Spectrometry Results of Water - Summary A-8.1 Gamma Spectrometry Results of Soil A-8.2 Gamma Spectrometry Results of Soil - Summary A-9.1 Gamma Spectrometry Results of Sediment A-9.2 Gamma Spectrometry Results of Sediment - Summary A-10.1 Gamma Spectrometry Results of Fish A-10.2 Gamma Spectrometry Results of Fish - Summary A-11.1 Iodine 131 in Milk A-11.2 Iodine 131 in Milk - Summary A-12.1 Gamma Spectrometry Results of Milk A-12.2 Gamma Spectrometry Results of Milk - Summary A-15.1 Gamma Spectrometry Results of Roots A-15.2 Gamma Spectrometry Results of Roots - Summary A-16.1 Gamma Spectrometry Results of Fruit A-16.2 Gamma Spectrometry Results of Fruit - Summary A-17.1 Gamma Spectrometry Results of Vegetables A-17.2 Gamma Spectrometry Results of Vegetables - Summary i

I APPENDIX A - TABLE OF CONTENTS n TABLE B: SPECIAL INTEREST SAMPLE RESULTS B-1.1 2009 Quarterly & Annual Special Interest Station TLD Results B-1.2 2009 Quarterly & Annual Special Interest Station TLD Results - Summary B-2.1 Gamma Spectrometry Results of Storm Drain Water B-2.2 Gamma Spectrometry Results of Storm Drain Water - Summary B-3.1 Gross Beta in Storm Drain Water B-3.2 Gross Beta in Storm Drain Water - Summary B-4.1 Tritium in Storm Drain Water I B-4.2 Tritium in Storm Drain Water - Summary B-5.1 Gross Alpha in Sanitary Waste Treatment Water B-5.2 Gross Alpha in Sanitary Waste Treatment Water - Summary B-6.1 Gross Beta in Sanitary Waste Treatment Water S B-6.2 Gross Beta in Sanitary Waste Treatment Water - Summary B-7.1 Gamma Spectrometry Results of Sanitary Waste Treatment Water B-7.2 Gamma Spectrometry Results of Sanitary Waste Treatment Water -,Summary B-8.1 Tritium in Sanitary Waste Treatment Water II B-8.2 Tritium in Sanitary Waste Treatment Water - Summary B-9.1 Special Isotopic Analysis Results of Monitoring Well Water B-10.1 Gamma Spectrometry Results of Groundwater Monitoring Samples B-10.2 Gamma Spectrometry Results of Groundwater Monitoring Samples - Summary B-11.1 Tritium in Monitoring Well Samples i B-12.1 Gross Alpha-Beta Results of Monitoring Well Water B-13.1 Gross Beta on Air Particulate Filters - Other Locations i B-14.1 Gamma Spectrometry Results of Air Particulate Filters - Other Locations I I ii i

FORWARD Since mid-1984, the results of the REMP analyses have been presented as net results calculated from total counts minus the observed background counts of the detection method. Counting results for low level samples are often within the counting error of the background determination; consequently results can range from negative to positive values in these samples. Though most of the analytical results presented in this Appendix are below the detection limit, listing the actual calculated value, even when it is negative or below the detection limit, prevents positive biases and loss of individual results inherent in the use of "less than" (<) values. It is standard practice to report radiological environmental data in this manner. Most results listed in this Appendix are accompanied by a plus or minus (+/-) error value. In most cases the error value represents the two sigma counting uncertainty determined for that particular analysis. These error values are in the same units as the listed activity values. The two sigma error value represents the range that a recount of the same sample would be expect to fall within 95% of the time, based on the statistics encountered in the original count. Also included in most case are the analysis specific, minimum detectable activity (MDA) values. Though similar in concept to the LLD, these values are based on the statistics encountered in the specific sample count itself and not a blank determination. As such, they are a a posteriori (after the fact) determination where the LLD is a a priori (before the fact) determination. These values were included as they represent the level of activity that would have needed to be present in the sample for a positive identification to be made. iii

TABLE A-1.1 2009 QUARTERLY & ANNUAL TLD RESULTS Results in milli-Roentgen (mR) Quarterly Annual TLD Ratio Quarterly Sum Result Sum / Annual Station ID 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 40 41 42 43 44 45 46 47 49 50 51 53 54 55 56 65 21.02 21.65 19.13 17.91 19.80 18.88 20.37 22.36 19.64 18.84 20.12 21.42 19.66 20.56 22.32 20.11 21.45 20.71 19.98 20.32 19.37 20.57 19.92 19.68 21.10 18.84 20.23 20.42 21.02 18.67 19.07 22.82 18.95 20.52 19.30 20.84 21.19 18.47 19.91 19.92 19.12 21.43 19.32 19.43 19.72 18.45 19.20 18.78 20.95 19.66 20.57 21.45 23.36 19.94 20.78 22.69 21.01 22.00 21.09 21.53 19.74 20.08 21.91 19.33 23.85 23.53 19.27 22.18 20.50 22.13 20.04 20.81 26.07 19.37 22.90 22.02 20.66 21.85 21.39 21.32 21.38 20.31 21.00 21.82 19.77 17.61 19.49 18.68 19.94 22.84 19.24 19.43 20.80 21.68 20.01 20.84 22.41 20.53 23.15 21.05 21.54 22.10 19.60 21.30 20.68 19.80 21.85 17.66 20.48 21.71 22.09 18.59 19.77 25.29 18.70 21.80 20.03 19.82 22.25 19.13 20.15 20.24 18.79 22.08 20.56 20.05 20.59 19.04 19.82 20.09 22.64 19.83 21.64 22.88 23.97 21.07 21.48 23.41 21.64 22.84 22.55 22.75 21.53 20.90 22.57 19.96 18.28 19.16 19.99 22.46 20.77 23.10 20.82 21.25 27.77 20.97 23.75 21.92 20.64 23.05 22.19 22.69 22.27 20.54 85.54 83.35 78.37 75.83 76.79 76.58 79.18 88.80 78.38 80.48 85.24 90.43 80.69 83.66 90.82 83.29 89.45 85.39 85.80 83.69 79.95 86.35 79.88 81.61 85.64 75.76 85.35 83.40 88.34 78.12 80.90 101.95 77.99 .88.97 83.27 81.96 88.34 81.19 84.07 83.81 78.76. 83.03 82.31 76.67 78.66 77.48 76.16 76.36 84.52 78.46 81.62 81.52 88.84 82.12 84.89 89.56 88.49 84.82 86.97 85.77 85.34 79.73 80.40 78.73 81.32 91.11 74.34 83.40 81.72 84.46 80.54 79.23 103.68 79.51 83.54 79.79 83.04 85.90 84.41 81.83 83.72 76.47 1.03 1.01 1.02 0.96 0.99 1.01 1.04 1.05 1.00 0.99 1.05 1.02 0.98 0.99 1.01 0.94 1.05 0.98 1.00 0.98 1.00 1.07 1.01 1.00 0.94 1.02 1.02 1.02 1.05 0.97 1.02 0.98 0.98 1.07 1.04 0.99 1.03 0.96 1.03 1.00 1.03 1st Q 12/30/08 to 3/31/09 - 2nd Q 3/31/09 to 6/25/09 - 3rd Q 6/25/09 to 9/25/09 - 4th 0 9/25/09 to 12/29/09 Page 1 of 2

I TABLE A-1.1 2009 QUARTERLY & ANNUAL TLD RESULTS Results in milli-Roentgen (mR) I Quarterly Annual TLD Ratio Quarterly Sum Result Sum / Annual Station ID 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 24.24 23.08 20.70 21.73 19.72 21.46 20.17 20.00 20.49 19.25 20.77 21.20 22.13 20.46 20.95 28.23 23.88 22.00 19.85 21.31 22.05 19.66 21.43 21.82 21.37 20.07 20.76 21.94 20.27 20.61 21.30 28.16 23.92 23.34 21.05 23.14 21.02 21.81 21.10 19.93 21.31 20.12 20.73 21.92 21.34 20.93 21.53 28.52 27.40 24.89 21.32 22.74 23.17 21.96 21.95 22.32 21.83 20.43 21.73 22.54 21.71 21.93 23.60 30.62 99.43 93.32 82.92 88.92 85.96 84.89 84.65 84.06 85.01 79.88 84.00 87.60 85.45 83.93 87.38 115.52 100.20 93.64 80.70 91.36 82.89 85.55 83.99 82.33 85.12 79.56 84.36 84.93 85.61 85.10 92.15 114.77 0.99 1.00 1.03 0.97 1.04 0.99 1.01 1.02 1.00 1.00 1.00 1.03 1.00 0.99 0.95 1.01 TABLE A-1.2 2009 QUARTERLY & ANNUAL TLD RESULTS-

SUMMARY

Results in milli-Roentgen (mR) Average Activity Activity Low Activity Number of Number of High Samples Positive IDs I U i i I I I I I I I I Location Quarterly Indicator TLDs 21.21 17.61 30.62 224 Quarterly Control TLDs 19.59 19.24 19.83 4 Annual Indicator TLDs 84.36 74.34 114.77 56 Annual Control TLDs 78.46 78.46 78.46 1 1 st Q 12/30/08 to 3/31/09 -2nd Q 3/31/09 to 6/25/09 - 3rd Q 6/25/09 to 9/25/09 -4th 0 9/25/09 to 12/29/09 224 4 56 1 Page 2 of 2 I

Table A-2.1 GROSS BETA ON AIR PARTICULATE FILTERS Results in pCi per Cubic Meter Station 01 Station 04 Station 05 Collection Period Result Error. Result Error Result Error.. 12/30/08 - 01/06/09 9.18E-03 + 6.13E-04 8.65E-03 + 5.99E-04 6.93E-03 + 5.43E-04 01/06/09 - 01/13/09 8.01E-03 + 5.74E-04 9.03E-03 + 6.04E-04 6.18E-03 + 5.14E-04 01/13/09 - 01/20/09 2.39E-02 + 9.60E-04 2.44E-02 + 9.70E-04 2.25E-02 + 9.32E-04 01/20/09 - 01/27/09 5.29E-02 + 1.44E-03 4.61E-02 + 1.34E-03 4.62E-02 + 1.34E-03 01/27/09 - 02/03/09 2.13E-02 + 8.98E-04 1.90E-02 + 8.49E-04 1.59E-02 + 7.82E-04 02/03/09 - 02/10/09 3.58E-02 + 1.16E-03 3.29E-02 _+ 1.11E-03 3.1OE-02 + 1.08E-03 02/10/09 - 02/17/09 1.77E-02 + 8.23E-04 1.57E-02 + 7.77E-04 1.66E-02 + 7.94E-04 02/17/09 - 02/24/09 3.29E-02 + 1.12E-03 2.93E-02 + 1.06E-03 2.56E-02 + 9.93E-04 02/24/09 - 03/03/09 8.22E-03 + 5.90E-04 9.46E-03 + 6.24E-04 7.82E-03 + 5.75E-04 03/03/09 - 03/10/09 1.09E-02 + 6.63E-04 9.89E-03 + 6.37E-04 1.01E-02 + 6.42E-04 03/10/09 - 03/17/09 2.06E-02 + 8.81E-04 1.72E-02 + 8.09E-04 1.66E-02 + 7.97E-04 03/17/09 - 03/24/09 9.09E-03 + 6.09E-04 8.58E-03 + 5.94E-04 7.46E-03 + 5.63E-04 03/24/09 - 03/31/09 9.49E-03 + 6.30E-04 7.68E-03 + 5.77E-04 6.86E-03 + 5.53E-04 03/31/09 - 04/07/09 7.79E-03 +.5.78E-04 9.55E-03 + 6.30E-04 8.88E-03 + 6.12E-04 04/07/09 - 04/14/09 8.34E-03 + 6.00E-04 6.83E-03 + 5.54E-04 6.29E-03 + 5.41E-04 04/14/09 - 04/21/09 1.36E-02 + 7.38E-04 1.18E-02 + 6.94E-04 1.22E-02 + 7.OOE-04 04/21/09 - 04/28/09 1.39E-02 + 7.30E-04 1.07E-02 + 6.51 E-04 1.11 E-02 + 6.63E-04 04/28/09 - 05/05/09 1.19E-02 + 6.97E-04 8.39E-03 + 6.04E-04 9.99E-03 + 6.46E-04 05/05/09 - 05/12/09 4.39E-03 + 4.91E-04 5.19E-03 + 5.20E-04 3.97E-03 + 4.75E-04 05/12/09 - 05/19/09 9.88E-03 + 6.30E-04 1.13E-02 + 6.67E-04 8.30E-03 + 5.82E-04 05/19/09 - 05/26/09 1.35E-02 + 7.14E-04 1.60E-02 + 7.76E-04 1.37E-02 + 7.20E-04 05/26/09 - 06/02/09 1.41 E-02 + 7.39E-04 1.47E-02 + 7.51 E-04 1.49E-02 + 7.57E-04 06/02/09 - 06/09/09 1.53E-02 + 7.61 E-04 1.43E-02 + 7.37E-04 1.45E-02 + 7.43E-04 06/09/09 - 06/16/09 1.71E-02 + 8.15E-04 -1.58E-02 + 7.81E-04 1.52E-02 + 7.70E-04 06/16/09 - 06/23/09 7.59E-03 + 5.74E-04 7.47E-03 + 5.74E-04 6.83E-03 + 5.48E-04 06/23/09 - 06/30/09 1.11E-02 + 6.67E-04 1.19E-02 + 6.87E-04 1.05E-02 + 6.55E-04 06/30/09 - 07/07/09 1.54E-02 + 7.85E-04 1.63E-02 + 8.06E-04 1.43E-02 + 7.60E-04 07/07/09 - 07/14/09 1.21 E-02 + 6.83E-04 1.38E-02 + 7.27E-04 1.21 E-02 + 6.83E-04 07/14/09 - 07/21/09 1.44E-02 + 7.45E-04 1.55E-02 + 7.73E-04 1.48E-02 + 7.57E-04 07/21/09 - 07/28/09 1.30E-02 + 7.20E-04 1.38E-02 + 7.38E-04 1.43E-02 + 7.52E-04 07/28/09 - 08/04/09 2.00E-02 + 8.77E-04 1.89E-02 + 8.54E-04 1.68E-02 + 8.06E-04 08/04/09 - 08/11/09 1.21E-02 + 7.08E-04 1.24E-02 + 7.16E-04 9.97E-03 + 6.54E-04 08/11/09 - 08/18/09 1.21E-02 + 8.03E-04 8.17E-03 + 5.86E-04 6.25E-03 + 5.27E-04 08/18/09 - 08/25/09 1.92E-02 + 9.40E-04 1.87E-02 + 8.56E-04 1.42E-02 + 7.57E-04 08/25/09 - 09/01/09 2.39E-02 + 9.54E-04 2.02E-02 + 8.76E-04 1.72E-02 + 8.18E-04 09/01/09 - 09/08/09 1.18E-02 + 6.83E-04 9.39E-03 + 6.18E-04 8.16E-03 + 5.83E-04 09/08/09 - 09/15/09 2.04E-02 + 8.82E-04 1.79E-02 + 8.32E-04 1.47E-02 _+ 7.63E-04 09/15/09 - 09/22/09 1.24E-02 + 7.06E-04 9.71 E-03 + 6.37E-04 7.82E-03 + 5.80E-04 09/22/09 - 09/29/09 2.43E-02 + 9.52E-04 2.30E-02 + 9.30E-04 1.57E-02 + 7.76E-04 09/29/09 - 10/06/09 1.32E-02 + 7.29E-04 1.09E-02 + 6.69E-04 9.74E-03 + 6.38E-04 10/06/09 - 10/13/09 1.77E-02 + 8.24E-04 2.17E-02 + 9.07E-04 1.99E-02 + 8.71E-04 10/13/09 - 10/20/09 1.92E-02 + 8.56E-04 1.81 E-02 + 8.30E-04 1.88E-02 + 8.47E-04 10/20/09 - 10/27/09 1.41E-02 + 7.38E-04 1.15E-02 + 6.79E-04 1.08E-02 + 6.61E-04 10/27/09 - 11/03/09 8.1OE-03 + 6.06E-04 8.02E-03 + 6.05E-04 NVS 11/03/09 - 11/10/09 1.70E-02 + 8.04E-04 1.67E-02 + 7.95E-04 1.74E-02 + 8.13E-04 11/10/09 - 11/17/09 1.25E-02 + 7.OOE-04 1.34E-02 + 7.25E-04 1.19E-02 + 6.91E-04 11/17/09 - 11/24/09 7.06E-03 + 5.46E-04 7.50E-03 + 5.65E-04 8.45E-03 + 5.92E-04 11/24/09 - 12/01/09 2.28E-02 + 9.29E-04 2.82E-02 + 1.04E-03 2.07E-02 + 8.78E-04 12/01/09 - 12/08/09 2.36E-02 + 9.41E-04 2.80E-02 + 1.02E-03 2.60E-02 + 1.01E-03 12/08/09 - 12/15/09 5.26E-02 + 1.42E-03 6.19E-02 + 1.56E-03 NVS 12/15/09 - 12/22/09 2.61E-02 + 9.94E-04 3.03E-02 + 1.08E-03 2.11E-02 + 8.93E-04 12/22/09 - 12/29/09 3.97E-02 + 1.22E-03 4.58E-02 + 1.31 E-03 4.26E-02 + 1.28E-03 NVS = Valid sample not obtained due to sampler failure. Average MDA for analysis listed in Table A-2.1 was 9.5E-04. Page l of 4

Table A-2.1 GROSS BETA ON AIR PARTICULATE FILTERS Results in pCi per Cubic Meter Station 06 Station 07.......Station 08 Collection. Period Result Error Result Error Result Error 12/30/08 - 01/06/09 1.12E-02 + 6.64E-04 1.19E-02 + 6.87E-04 1.03E-02 + 6.41E-04 01/06/09 - 01/13/09 7.47E-03 + 5.54E-04 1.21E-02 + 6.84E-04 5.72E-03 + 5.OOE-04 01/13/09 - 01/20/09 2.70E-02 + 1,.02E-03 3.02E-02 + 1.08E-03 2.66E-02 + 1.01E-03 01/20/09 - 01/27/09 5.78E-02. + 1:.51 E-03 6.61 E-02 + 1.62E-03 5.33E-02 + 1.44E-03 01/27/09 - 02/03/09 2.08E-02 + 8.89E-04 2.56E-02 + 9.82E-04 1.88E-02 + 8.46E-04 02/03/09 - 02/10/09 3.97E-02 + 1.23E-03 4.26E-02 + 1.27E-03 3.26E-02 + 1.11E-03 02/10/09 - 02/17/09 1.79E-02 + 8.25E-04 2.33E-02 + 9.33E-04 1.70E-02 + 8.05E-04 02/17/09 - 02/24/09 3.68E-02 + 1.19E-03 3.95E-02 + 1.23E-03 3.09E-02 + 1.09E-03 02/24/09 - 03/03/09 1.05E-02 + 6.52E-04 1.41 E-02 + 7.44E-04 1.04E-02 + 6.50E-04 03/03/09 - 03/10/09 1.12E-02 + 6.72E-04 1.17E-02 + 6.86E-04 1.09E-02 + 6.63E-04 03/10/09 - 03/17/09 2.1OE-02 + 8.90E-04 2.60E-02 + 9.86E-04 2.11E-02 + 8.92E-04 03/17/09 - 03/24/09 9.63E-03 + 6.26E-04 1.19E-02 + 6.82E-04 8.81E-03 + 6.01E-04 03/24/09 - 03/31/09 8.08E-03 + 5.90E-04 9.44E-03 + 6.31 E-04 8.22E-03 + 5.93E-04 03/31/09 - 04/07/09 1.09E-02 + 6.63E-04 1.18E-02 + 6.87E-04 9.43E-03 + 6.27E-04 04/07/09 - 04/14/09 8.54E-03 + 6.09E-04 7.79E-03 + 5.87E-04 7.11E-03 + 5.66E-04 04/14/09 - 04/21/09 1.39E-02 + 7.46E-04 1.58E-02 + 7.88E-04 1.32E-02 + 7.26E-04 04/21/09 - 04/28/09 1.34E-02 + 7.21 E-04 1.47E-02 + 7.53E-04 1.31 E-02 + 7.15E-04 04/28/09 - 05/05/09 1.01E-02 + 6.49E-04 1.33E-02 + 7.32E-04 1.08E-02 + 6.65E-04 05/05/09 - 05/12/09 5.66E-03 + 5.36E-04 6.06E-03 + 5.44E-04 5.54E-03 + 5.28E-04 05/12/09 - 05/19/09 9.08E-03 + 6.05E-04 1.04E-02 + 6.43E-04 9.56E-03 + 6.20E-04 05/19/09 - 05/26/09 1.34E-02 + 7.12E-04 1.45E-02 + 7.38E-04 1.31E-02 + 7.06E-04 05/26/09 - 06/02/09 1.54E-02 + 7.68E-04 1.93E-02 + 8.58E-04 1.56E-02 + 7.73E-04 06/02/09 - 06/09/09 1.60E-02 + 7.80E-04 1.51 E-02 + 7.60E-04 1.21 E-02 + 6.84E-04 06/09/09 - 06/16/09 1.54E-02 + 7.75E-04 1.95E-02 + 8.62E-04 1.59E-02 + 7.86E-04 06/16/09 - 06/23/09 8.54E-03 + 6.04E-04 8.99E-03 + 6.15E-04 6.1OE-03 + 5.27E-04 06/23/09 - 06/30/09 1.06E-02 + 6.50E-04 1.24E-02 + 6.98E-04 9.19E-03 + 6.18E-04 06/30/09 - 07/07/09 1.56E-02 + 7.88E-04 1.75E-02 + 8.33E-04 1.38E-02 + 7.45E-04 07/07/09 - 07/14/09 1.16E-02 + 6.73E-04 1.40E-02 + 7.33E-04 1.28E-02 + 7.02E-04 07/14/09 - 07/21/09 1.58E-02 + 7.82E-04 1.50E-02 + 7.61E-04 1.39E-02 + 7.36E-04 07/21/09 - 07/28/09 1.61E-02 + 7.91E-04 1.69E-02 + 8.08E-04 1.73E-02 + 8.20E-04 07/28/09 - 08/04/09 1.93E-02 + 8.64E-04 2.12E-02 + 9.01E-04 2.05E-02 + 8.86E-04 08/04/09 - 08/11/09 1.26E-02 + 7.19E-04 1.24E-02 + 7.15E-04 1.34E-02 + 7.37E-04 08/11/09 - 08/18/09 7.48E-03 + 5.65E-04 6.35E-03 + 5.29E-04 8.11E-03 + 5.86E-04 08/18/09 - 08/25/09 1.81E-02 + 8.41E-04 2.02E-02 + 8.87E-04 1.92E-02 + 8.71E-04 08/25/09 - 09/01/09 2.11 E-02 + 8.97E-04 2.36E-02 + 9.47E-04 2.13E-02 + 9.06E-04 09/01/09 - 09/08/09 9.92E-03 + 6.32E-04 1.06E-02 + 6.52E-04 1.16E-02 + 6.80E-04 09/08/09 - 09/15/09 1.77E-02 + 8.27E-04 1.84E-02 + 8.42E-04 1.82E-02 + 8.39E-04 09/15/09 - 09/22/09 1.10E-02 + 6.67E-04 1.04E-02. + 6.52E-04 1.07E-02 + 6.64E-04 09/22/09 - 09/29/09 1.99E-02 + 8.66E-04 2.OOE-02 + 8.67E-04 2.01 E-02 + 8.69E-04 09/29/09 - 10/06/09 1.11E-02 + 6.76E-04 1.61E-02 + 7.95E-04 1.09E-02 + 6.69E-04 10/06/09 - 10/13/09 1.50E-02 + 7.60E-04 1.72E-02 + 8.14E-04 1.88E-02 + 8.43E-04 10/13/09 - 10/20/09 1.75E-02 + 8.19E-04 1.69E-02 + 8.08E-04 1.85E-02 + 8.40E-04 10/20/09 - 10/27/09 9.31E-03 + 6.20E-04 1.18E-02 + 6.83E-04 1.24E-02 + 7.OOE-04 10/27/09 - 11/03/09 7.33E-03 + 5.84E-04 7.39E-03 + 5.86E-04 7.45E-03 + 5.87E-04 11/03/09 - 11/10/09 1.52E-02 + 7.66E-04 1.49E-02 + 7.55E-04 1.55E-02 + 7.71E-04 11/10/09 - 11/17/09 9.30E-03 + 6.20E-04 1.14E-02 + 6.76E-04 1.26E-02 + 7.06E-04 11/17/09 - 11/24/09 7.43E-03 + 5.58E-04 6.58E-03 + 5.34E-04 6.28E-03 + 5.26E-04 11/24/09 - 12/01/09 2.25E-02 + 9.16E-04 1.74E-02 + 8.60E-04 1.94E-02 + 8.51E-04 12/01/09 - 12/08/09 2.48E-02 + 9.70E-04 2.19E-02 + 9.12E-04 2.50E-02 + 9.97E-04 12/08/09 - 12/15/09 5.08E-02 + 1.40E-03 6.20E-02 + 1.56E-03 4.94E-02 + 1.37E-03 12/15/09 - 12/22/09 2.70E-02 + 1.01E-03 3.07E-02 + 1.08E-03 2.16E-02 + 9.04E-04 12/22/09 - 12/29/09 3.60E-02 + 1.17E-03 4.36E-02 + 1.29E-03 3.65E-02 + 1.18E-03 I I I I I I I I I I I I I I I I I I NVS = Valid sample not obtained due to sampler failure. Average MDA for analysis listed in Table A-2.1 was 9.5E-04. Page 2 of 4

Table A-2.1 GROSS BETA ON AIR PARTICULATE FILTERS Results in pCi per Cubic Meter Station 09 Station 21 Station 23 Collection Period Result Error Result Error Result Error.. 12/30/08 - 01/06/09 8.16E-03 + 5.81E-04 9.75E-03 + 6.27E-04 1.09E-02 + 6.57E-04 01/06/09 - 01/13/09 7.87E-03 + 5.70E-04 6.50E-03 + 5.28E-04 6.53E-03 + 5.29E-04 01/13/09 - 01/20/09 2.01E-02 + 8.86E-04 2.42E-02 + 9.64E-04 2.54E-02 + 9.88E-04 01/20/09 - 01/27/09 4.51E-02 + 1.32E-03 5.20E-02 + 1.42E-03 5.80E-02 + 1.51E-03 01/27/09 - 02/03/09 9.82E-03 + 6.29E-04 1.97E-02 + 8.65E-04 2.05E-02 + 8.85E-04 02/03/09 - 02/10/09 3.40E-02 + 1.13E-03 3.32E-02 + 1.12E-03 4.14E-02 + 1.26E-03 02/10/09 - 02/17/09 1.32E-02 + 7.24E-04 1.52E-02 + 7.63E-04 2.11E-02 + 8.95E-04 02/17/09 - 02/24/09 2.90E-02 + 1.07E-03 2.65E-02 + 1.01E-03 3.55E-02 + 1.17E-03 02/24/09 - 03/03/09 1.OOE-02 + 6.40E-04 9.96E-03 + 6.38E-04 1.21 E-02 + 6.92E-04 03/03/09 - 03/10/09 8.41 E-03 + 5.95E-04 1.04E-02 + 6.51 E-04 1.35E-02 + 7.30E-04 03/10/09 - 03/17/09 1.61E-02 + 7.85E-04 2.08E-02 + 8.87E-04 2.28E-02 + 9.28E-04 03/17/09 - 03/24/09 5.58E-03 + 5.01E-04 6.71E-03 + 5.37E-04 9.38E-03 + 6.17E-04 03/24/09 - 03/31/09 7.52E-03 + 5.76E-04 8.30E-03 + 5.97E-04 9.74E-03 + 6.39E-04 03/31/09 - 04/07/09 9.84E-03 + 6.36E-04 9.83E-03 + 6.36E-04 1.35E-02 + 7.33E-04 04/07/09 - 04/14/09 8.05E-03 + 5.96E-04 7.67E-03 + 5.80E-04 1.07E-02 + 6.67E-04 04/14/09 - 04/21/09 1.25E-02 + 7.08E-04 1.41E-02 + 7.48E-04 1.59E-02 + 7.92E-04 04/21/09 - 04/28/09 1.34E-02 + 7.20E-04 1.29E-02 + 7.06E-04 1.69E-02 + 8.04E-04 04/28/09 - 05/05/09 1.17E-02 + 6.91E-04 1.70E-02 + 8.16E-04 1.34E-02 + 7.36E-04 05/05/09 - 05/12/09 5.23E-03 + 5.24E-04 9.86E-03 + 6.54E-04 6.62E-03 + 5.64E-04 05/12/09 - 05/19/09 9.89E-03 + 6.28E-04 1.36E-02 + 7.29E-04 1.18E-02 + 6.81E-04 05/19/09 - -05/26/09 1.40E-02 + 7.29E-04 2.01E-02 + 8.65E-04 1.41E-02 + 7.28E-04 05/26/09 - 06/02/09 1.74E-02 + 8.15E-04 2.31E-02 + 9.34E-04 1.91E-02 + 8.54E-04 06/02/09 - 06/09/09 1.64E-02 + 7.88E-04 1.90E-02 + 8.45E-04 1.58E-02 + 7.75E-04 06/09/09 - 06/16/09 1.81E-02 + 8.33E-04 2.29E-02 + 9.32E-04 1.81E-02 + 8.34E-04 06/16/09 - 06/23/09 8.68E-03 _+ 6.03E-04 1.12E-02 + 6.79E-04 9.24E-03 + 6.23E-04 06/23/09 - 06/30/09 1.07E-02 + 6.56E-04 1.51 E-02 + 7.63E-04 1.20E-02 + 6.89E-04 06/30/09 - 07/07/09 1.55E-02 + 7.90E-04 2.35E-02 + 9.59E-04 1.81 E-02 + 8.46E-04 07/07/09 - 07/14/09 1.11E-02 + 6.59E-04 1.79E-02 + 8.23E-04 1.14E-02 + 6.71E-04 07/14/09 - 07/21/09 1.48E-02 + 7.56E-04 2.20E-02 + 9.12E-04 1.74E-02 + 8.12E-04 07/21/09 - 07/28/09 1.53E-02 + 7.78E-04 2.21E-02 + 9.19E-04 1.54E-02 + 7.78E-04 07/28/09 - 08/04/09 2.06E-02 + 8.88E-04 2.65E-02 + 1.OOE-03 2.09E-02 *+ 8.97E-04 08/04/09 - 08/11/09 1.04E-02 + 6.63E-04 1.88E-02 + 8.60E-04 1.29E-02 + 7.24E-04 08/11/09 - 08/18/09 7.34E-03 + 5.63E-04 5.12E-03 + 4.89E-04 7.64E-03 + 5.71E-04 08/18/09 - 08/25/09 1.85E-02 + 8.51E-04 2.55E-02 + 9.92E-04 1.75E-02 + 8.29E-04 08/25/09 - 09/01/09 1.80E-02 + 8.35E-04 2.69E-02 + 1.01 E-03 2.24E-02 + 9.26E-04 09/01/09 - 09/08/09 1.07E-02 + 6.56E-04 1.61E-02 + 7.84E-04 1.19E-02 + 6.86E-04 09/08/09 - 09/15/09 1.63E-02 + 7.98E-04 2.61E-02 + 9.97E-04 1.70E-02 + 8.15E-04 09/15/09 - 09/22/09 8.84E-03 + 6.13E-04 1.68E-02 + 8.08E-04 1.01E-02 + 6.45E-04 09/22/09 - 09/29/09 1.84E-02 + 8.36E-04 2.75E-02 + 1.01 E-03 2.OOE-02 + 8.68E-04 09/29/09 - 10/06/09 8.99E-03 + 6.19E-04 1.68E-02 + 8.11E-04 1.05E-02 + 6.58E-04 10/06/09 - 10/13/09 2.OOE-02 + 8.73E-04 2.19E-02 + 9.11E-04 1.67E-02 + 8.03E-04 10/13/09 - 10/20/09 1.45E-02 + 7.49E-04 2.19E-02 + 9.09E-04 1.75E-02 + 8.19E-04 10/20/09 - 10/27/09 8.97E-03 + 6.13E-04 1.59E-02 + 7.82E-04 1.09E-02 + 6.62E-04 10/27/09 - 11/03/09 6.55E-03 + 5.60E-04 8.28E-03 + 6.11E-04 5.34E-03 + 5.22E-04 11/03/09 - 11/10/09 1.32E-02 + 7.13E-04 2.02E-02 + 8.73E-04 1.53E-02 + 7.65E-04 11/10/09 - 11/17/09 1.13E-02 + 6.74E-04 1.42E-02 + 7.44E-04 9.68E-03 + 6.31E-04 11/17/09 - 11/24/09 6.13E-03 + 5.17E-04 6.23E-03 + 5.25E-04 NVS 11/24/09 - 12/01/09 1.97E-02 + 8.59E-04 2.62E-02 + 9.92E-04 2.37E-02 + 9.45E-04 12/01/09 - 12/08/09 2.32E-02 + 9.43E-04 2.90E-02 + 1.05E-03 2.91E-02 + 1.05E-03 12/08/09 - 12/15/09 5.06E-02 + 1.39E-03 6.12E-02 + 1.55E-03 5.96E-02 + 1.64E-03 12/15/09 - 12/22/09 2.95E-02 + 1.05E-03 3.05E-02 + 1.07E-03 1.41 E-02 + 7.38E-04 12/22/09 - 12/29/09 3.62E-02 + 1.17E-03 4.48E-02 + 1.31E-03 4.55E-02 + 1.32E-03 NVS = Valid sample not obtained due to sampler failure. Average MDA for analysis listed in Table A-2.1 was 9.5E-04. Page 3 of 4

Table A-2.1 GROSS BETA ON AIR PARTICULATE FILTERS Results in pCi per Cubic Meter Station 4.0 Station 48 Station 57 Collection Period Result Error Result Error Result Error 12/30/08 - 01/06/09 1.29E-02 + 7.11E-04 1.12E-02 + 6.64E-04 9.33E-03 + 6.14E-04 01/06/09 - 01/13/09 1.04E-02 + 6.39E-04 6.98E-03 + 5.41E-04 8.01E-03 + 5.73E-04 01/13/09 - 01/20/09 3.73E-02 + 1.20E-03 2.63E-02 + 1.01E-03 3.05E-02 + 1.08E-03 01/20/09 - 01/27/09 7.78E-02 + 1.78E-03 5.55E-02 + 1.47E-03 5.27E-02 + 1.43E-03 01/27/09 - 02/03/09 2.51 E-02 + 9.74E-04 2.05E-02 + 8.83E-04 1.88E-02 + 8.45E-04 02/03/09 - 02/10/09 4.95E-02 + 1.38E-03 3.84E-02 + 1.21E-03 3.42E-02 + 1.14E-03 02/10/09 - 02/17/09 2.62E-02 + 9.92E-04 1.92E-02 + 8.52E-04 1.69E-02 + 8.04E-04 02/17/09 - 02/24/09 4.35E-02 + 1.30E-03 3.04E-02 + 1.08E-03 3.18E-02 + 1.11E-03 02/24/09 - 03/03/09 1.45E-02 + 7.52E-04 1.13E-02 + 6.74E-04 3.83E-03 + 7.65E-04 03/03/09 - 03/10/09 1.43E-02 + 7.52E-04 1.06E-02 + 6.58E-04 9.40E-03 + 6.23E-04 03/10/09 - 03/17/09 2.51 E-02 + 9.72E-04 1.84E-02 + 8.38E-04 2.31 E-02 + 9.31 E-04 03/17/09 - 03/24/09 1.14E-02 + 6.73E-04 9.24E-03 + 6.13E-04 9.48E-03 + 6.20E-04 03/24/09 - 03/31/09 1.02E-02 + 6.54E-04 7.80E-03 + 5.82E-04 9.33E-03 + 6.27E-04 03/31/09 - 04/07/09 1.24E-02 + 7.06E-04 1.05E-02 + 6.55E-04 1.02E-02 + 6.47E-04 04/07/09 - 04/14/09 1.14E-02 + 6.84E-04 7.02E-03 + 5.61E-04 8.77E-03 + 6.13E-04 04/14/09 - 04/21/09 1.81E-02 + 8.38E-04 1.36E-02 + 7.35E-04 1.33E-02 + 7.27E-04 04/21/09 - 04/28/09 1.61 E-02 + 7.83E-04 1.29E-02 + 7.08E-04 1.24E-02 + 6.94E-04 04/28/09 - 05/05/09 1.46E-02 + 7.62E-04 1.01 E-02 + 6.50E-04 1.26E-02 + 7.14E-04 05/05/09 - 05/12/09 7.90E-03 + 6.OOE-04 4.91E-03 + 5.1OE-04 4.76E-03 + 5.05E-04 05/12/09 - 05/19/09 1.13E-02 + 6.65E-04 8.23E-03 + 5.81E-04 9.17E-03 + 6.09E-04 05/19/09 - 05/26/09 1.77E-02 + 8.15E-04 1.16E-02 + 6.74E-04 1.29E-02 + 7.02E-04 05/26/09 - 06/02/09 1.49E-02 + 7.58E-04 1.44E-02 + 7.48E-04 1.87E-02 + 3.63E-01 06/02/09 - 06/09/09 1.43E-02 + 7.40E-04 1.19E-02 + 6.79E-04 1.50E-02 + 7.57E-04 06/09/09 - 06/16/09 1.60E-02 + 7.90E-04 1.62E-02 + 7.91 E-04 1.89E-02 + 8.50E-04 06/16/09 - 06/23/09 8.49E-03 + 6.01E-04 5.52E-03 + 5.10E-04 7.59E-03 + 5.72E-04 06/23/09 - 06/30/09 1.05E-02 + 6.53E-04 8.48E-03 + 5.95E-04 1.20E-02 + 6.90E-04 06/30/09 - 07/07/09 1.54E-02 + 7.89E-04 1.29E-02 + 7.25E-04 11.92E-02 + 8.66E-04 07/07/09 - 07/14/09 1.19E-02 + 6.81E-04 6.70E-03 + 5.31E-04 1.27E-02 + 7.02E-04 07/14/09 - 07/21/09 1.49E-02 + 7.59E-04 1.56E-02 + 7.74E-04 1.80E-02 + 8.29E-04 07/21/09 - 07/28/09 1.54E-02 + 7.77E-04 1.52E-02 + 7.72E-04 1.74E-02 + 8.25E-04 07/28/09 - 08/04/09 1.91 E-02 + 8.59E-04 1.87E-02 + 8.51 E-04 2.32E-02 + 9.41 E-04 08/04/09 - 08/11/09 1.17E-02 + 6.96E-04 1.12E-02 + 6.84E-04 1.54E-02 + 7.82E-04 08/11/09 - 08/18/09 6.67E-03 + 5.44E-04 7.51 E-03 + 5:66E-04 7.30E-03 + 5.62E-04 08/18/09 - 08/25/09 1.43E-02 + 7.59E-04 1.88E-02 + 8.60E-04 1.93E-02 + 8.70E-04 08/25/09 - 09/01/09 1.95E-02 + 8.66E-04 2.08E-02 + 8.92E-04 2.24E-02 + 9.23E-04 09/01/09 - 09/08/09 9.15E-03 + 6.14E-04 1.34E-02 + 9.19E-04 1.05E-02 + 6.50E-04 09/08/09 - 09/15/09 1.74E-02 + 8.23E-04 1.89E-02 + 8.57E-04 1.94E-02 + 8.64E-04 09/15/09 - 09/22/09 1.12E-02 + 6.72E-04 1.15E-02 + 6.82E-04 1.11E-02 + 6.72E-04 09/22/09 - 09/29/09 1.75E-02 + 8.13E-04 2.05E-02 + 8.78E-04 2.04E-02 + 8.75E-04 09/29/09 - 10/06/09 1.14E-02 + 6.82E-04 1.67E-02 + 8.08E-04 1.15E-02 + 6.86E-04 10/06/09 - 10/13/09 1.53E-02 + 7.69E-04 2.07E-02 + 8.87E-04 1.78E-02 + 8.28E-04 10/13/09 - 10/20/09 1.49E-02 + 7.60E-04 1.84E-02 + 8.40E-04 1.87E-02 + 8.43E-04 10/20/09 - 10/27/09 9.51E-03 + 6.23E-04 1.30E-02 + 7.16E-04 1.09E-02 + 6.61E-04 10/27/09 - 11/03/09 6.40E-03 + 5.58E-04 7.38E-03 + 5.86E-04 7.03E-03 + 5.76E-04 11/03/09 - 11/10/09 1.41E-02 + 7.37E-04 1.36E-02 + 7.26E-04 1.64E-02 + 7.90E-04 11/10/09 - 11/17/09 1.04E-02 + 6.48E-04 1.38E-02 + 7.35E-04 1.05E-02 + 6.52E-04 11/17/09 - 11/24/09 7.41E-03 + 5.59E-04 6.56E-03 + 5.33E-04 5.41E-03 + 4.93E-04 11/24/09 - 12/01/09 2.16E-02 + 8.96E-04 2.16E-02 + 8.97E-04 2.01E-02 + 8.74E-04 12/01/09 - 12/08/09 2.88E-02 + 1.17E-03 2.41E-02 + 9.57E-04 2.29E-02 + 9.32E-04 12/08/09 - 12/15/09 5.29E-02 + 1.43E-03 5.25E-02 + 1.42E-03 4.50E-02 + 1.31 E-03 12/15/09 - 12/22/09 2.18E-02 + 9.06E-04 2.54E-02 + 9.77E-04 2.22E-02 + 9.18E-04 12/22/09 - 12/29/09 4.21E-02 + 1.27E-03 3.97E-02 + 1.23E-03 3.28E-02 + 1.11E-03 I I I U I I i I i I i i U I I I I NVS = Valid sample not obtained due to sampler failure. Average MDA for analysis listed in Table A-2.1 was 9.5E-04. Page 4 of 4

Table A-2.2 GROSS BETA ON AIR PARTICULATE FILTERS -

SUMMARY

Results in pCi per cubic meter LOCATION Gross Beta Indicators Gross Beta Controls Average Activity 1.74E-02 1.55E-02 Activity Activity Low High -8.73E-04 7.78E-02 5.23E-03 5.06E-02 Number of Samples Number of Positive IDs 569 52 569 52 Page 1 of 1

TABLE A-3.1 GAMMA SPECTROMETRY RESULTS OF AIR PARTICULATE FILTERS Results in pCi/cubic meter, results decay corrected for decay during sample collection period Location and Quarter Station 1 1st Q 09 -Nu-c-ide RQ Activity Error MDA I Location and Quarter Station 1 2nd Q 09 INuclide RQ Activity Error MDA7] BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 RU-106 + 1.04E-01 + -1.40E-03 + 1.95E-04 + 0.OOE+00 + -2.93E-05 + 0.OOE+00 + -3.56E-04 + 5.01 E-06 + -1.83E-04 + 0.OOE+00 + -1.55E-03 + 1.57E-02 1.05E-02 5.24E-04 3.23E-03 6.30E-04 2.37E-03 8.33E-04 5.00E-04 5.98E-04 3.23E-03 5.13E-03 9.72E-03 1.30E-02 8.OOE-04 5.38E-03 1.03E-03 3.96E-03 1.27E-03 8.22E-04 9.41 E-04 5.39E-03 8.06E-03 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 RU-106 + 1.63E-01 + -1.13E-03 + 1.20E-04 + 1.24E-03 + 0.OOE+00 + O.OOE+00 + 2.02E-05 + -7.47E-05 + 9.82E-05 + -2.93E-03 + 9.35E-04 + 1.89E-02 8.OOE-03 5.39E-04 2.85E-03 1.66E-04 1.68E-03 6.13E-04 4.45E-04 3.99E-04 1.10E-02 4.12E-03 8.95E-03 1.15E-02 8.50E-04 4.21 E-03 2.77E-04 2.79E-03 1.OOE-03 7.13E-04 6.21 E-04 1.70E-02 6.49E-03 Location and Quarter Station 1 3rd Q 09 [Nuclide RQ Activity Error MDA I Location and Quarter Station 1 4th Q 09 [Nuclide RQ Activity Error MO-A* BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-1 34 CS-137 BALA 40 RU-106 + 1.94E-01 + -2.20E-03 + 0.OOE+00 + 1.01 E-03 + 0.OOE+00 + -1.78E-04 + 1.95E-05 + 3.79E-06 + 1.26E-04 + -1.84E-03 + 0.00E+00 + 2.17E-02 1.18E-02 5.06E-04 3.15E-03 8.36E-04 1.18E-03 6.94E-04 5.92E-04 4.31 E-04 1.57E-02 5.56E-03 9.78E-03 1.21 E-02 8.43E-04 4.79E-03 1.39E-03 1.87E-03 1.13E-03 9.73E-04 6.67E-04 2.52E-02 9.26E-03 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA 40 RU-106 + 1.06E-01 + 1.10E-03 + -1.49E-04 + 8.90E-04 + 1.78E-04 + 0.OOE+00 + O.OOE+00 + 1.49E-04 + 6.64E-06 + 0.OOE+00 + -7.85E-04 + 1.41 E-02 4.12E-03 5.51 E-04 1.88E-03 3.88E-04 1.57E-03 1.63E-04 3.73E-04 3.51 E-04 4.01 E-03 3.56E-03 6.94E-03 7.99E-03 8.71 E-04 2.62E-03 5.64E-04 2.62E-03 2.71 E-04 5.77E-04 5.75E-04 6.69E-03 5.64E-03 I I I I I I 1 I U I 1 I U I 1 lI I I! 1 Location and Quarter Station 4 1St Q 09 [Niicfide RQ Activity Error MDA ] Location and Quarter Station 4 2nd Q 09 [Nf-cile RQ Activity - Error MD-A--- BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 RU-106 + 9.10E-02 + -6.OOE-03 + -5.65E-05 + 0.OOE+00 + 1.92E-04 + 0.OOE+00 + 3.43E-04 + -1.25E-06 + -7.94E-05 + 0.OOE+00 + -1.35E-03 + 1.53E-02 4.70E+00 5.99E-04 8.89E-04 4.74E-04 2.06E-03 6.52E-04 4'25E-04 5.71 E-04 3.42E-03 5.53E-03 1.06E-02 1.37E-02 9.70E-04 1.48E-03 6.95E-04 3.44E-03 9.45E-04 6.99E-04 9.20E-04 5.69E-03 8.79E-03 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA 40 RU-106 + 1.56E-01 + -2.48E-03 + -7.78E-05 + 0.OOE+00 + 0.OOE+00 + -4.24E-04 + 0.OOE+00 + -3.66E-06 + -8.52E-06 + 3.61 E-03 + -4.47E-04 + 1.94E-02 1.45E-02 5.94E-04 3.27E-03 1.66E-04 1.33E-03 1.28E-03 4.87E-04 4.99E-04 1.03E-02 4.41 E-03 1.14E-02 1.26E-02 9.56E-04 5.46E-03 2.77E-04 2.06E-03 2.14E-03 8.OOE-04 8.18E-04 1.55E-02 7.13E-03 Location and Quarter Station 4 3rd Q 09 [Nuclide RQ Activity Error MDA ] BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-1 34 CS-1 37 BALA 40 RU-l06 + 1.94E-01 + -2.20E-03 + 0.OOE+00 + 1.01 E-03 + 0.OOE+00 + -1.78E-04 + 1.95E-05 + 3.79E-06 + 1.26E-04 + -1.84E-03 + O.OOE+00 + 2.17E-02 1.18E-02 5.06E-04 3.15E-03 8.36E-04 1.18E-03 6.94E-04 5.92E-04 4.31 E-04 1.57E-02 5.56E-03 9.78E-03 1.21 E-02 8.43E-04 4.79E-03 1.39E-03 1.87E-03 1.13E-03 9.73E-04 6.67E-04 2.52E-02 9.26E-03 Location and Quarter Station 4 4th 0 09 [Nu-clidie RQ Acivity Error M -A-- BE-7 + 1.14E-01 + 1.44E-02 4.01E-03 K-40 -3.69E-03 + 5.42E-02 1.OOE-02 MN-54 4.68E-05 + 4.25E-04 6.85E-04 FE-59 1.27E-03 + 1.88E-03 2.34E-03 CO-60 1.06E-04 + 4.47E-04 6.99E-04 ZN-65 -2.29E-04 + 8.56E-04 1.31 E-03 ZRNB-95 2.55E-04 + 5.96E-04 8.90E-04 CS-134 -2.17E-06 + 3.37E-04 5.54E-04 CS-137 -1.06E-04 + 3.84E-04 6.02E-04 BALA140 0.OOE+00 + 4.98E-03 8.30E-03 RU-106 4.40E-04 + 3.77E-03 6.09E-03 RO = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. 1 st Q 1/1/09 to 3/31/09 - 2nd 0 3/31/09 to 6/30/09 - 3rd Q 6/30/09 to 9/29/09 - 4th 0 9/29/09 to 12/29/09 Page 1 of 6

TABLE A-3.1 GAMMA SPECTROMETRY RESULTS OF AIR PARTICULATE FILTERS Results in pCi/cubic meter, results decay corrected for decay during sample collection period Location and Quarter Station 5 1St Q 09 FfNu-rlide RQ Activity Error MDA-7 Location and Quarter Station 5 2nd Q 09 [Nuclide RQ Activity Error MDA BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-1 34 CS-1 37 BALA 40 RU-1 06 + 8.24E-02 + -3.51 E-03 + -9.26E-05 + -1.89E-04 + -3.59E-06 + 0.OOE+00 + -7.33E-05 + -4.07E-05 + 1.86E-04 + 0.OOE+00 + 0.OOE+00 + 1.49E-02 2.72E-02 6.03E-04 2.54E-03 4.41 E-04 1.19 E-03 7.83E-04 4.47E-04 3.71 E-04 3.43E-03 3.89E-03 1.09E-02 1.44E-02 9.67E-04 4.09E-03 7.23E-04 1.98E-03 1.27E-03 7.25E-04 5.37E-04 5.71 E-03 6.49E-03 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 RU-106 + 1.54E-01 + -2.20E-03 + 1.12E-04 + 1.02E-03 + 0.OOE+00 + 1.22E-04 + -9.97E-05 + -7.78E-05 + 2.70E-05 + O.OOE+00 + 5.49E-04 + 1.89E-02 1.25E-02 3.92E-04 2.31 E-03 8.11 E-04 1.27E-03 8.37E-04 5.14E-04 3.72E-04 3.41 E-03 3.88E-03 9.62E-03 1.23E-02 5.97E-04 3.30E-03 1.35E-03 2.04E-03 1.35E-03 8.28E-04 6.02E-04 5.69E-03 6.20E-03 Location and Quarter Station 5 3rd Q 09 [Nuclide RQ Activity Error MDA ] Location and Quarter Station 5 4th 0 09 iNuclide RQ -Ac-ivity Error MDA7 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 RU-106 + 1.54E-01 + -4.61 E-03 + 1.46E-04 + -1.34E-03 + 0.OOE+00 _+ -8.13E-05 + 1.53E-04 + 1.57E-05 + -2.64E-05 + 0.OOE+00 + -1.35E-03 + 1.89E-02 4.17E-02 5.22E-04 3.95E-03 5.74E-04 1.08E-03 8.71 E-04 4.86E-04 4.30E-04 2.69E-02 4.95E-03 8.59E-03 1.25E-02 8.11 E-04 6.10E-03 9.57E-04 1.74E-03 1.39E-03 7.96E-04 6.98E-04 4.48E-02 7.80E-03 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-1 34 CS-1 37 BALA 40 RU-106 + 9.79E-02 + 2.00E-03 + 0.OOE+00 + 0.OOE+00 + 2.38E-04 + -1.28E-04 + 1.67E-04 + 2.69E-06 + 0.OOE+00 + 0.OOE+00 + -4.81 E-04 + 1.52E-02 5.32E-03 3.41 E-04 4.66E-03 4.73E-04 1.41 E-03 6.82E-04 3.20E-04 3.69E-04 2.97E-02 3.77E-03 8.20E-03 9.82E-03 5.68E-04 7.77E-03 6.83E-04 2.28E-03 1.06E-03 5.26E-04 6.15E-04 4.96E-02 6.05E-03 Location and Quarter Station 6 1St Q 09 [Nuclide-. RQ Activity Error MDA I Location and Quarter Station 6 2nd Q 09 [Nuclide RQ Activity Error MDA-] BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-1 34 CS-137 BALA1 40 RU-106 + 1.05E-01 + -1.43E-03 + 1.10E-04 + 0.OOE+00 + 3.14E-04 + -3.76E-04 + -3.55E-05 + 1.18E-04 + -2.61 E-05 + 3.12E-03 + 9.28E-04 + 1.62E-02 1.20E-02 5.23E-04 8.91 E-04 5.18E-04 1.19E-03 8.36E-04 4.38E-04 4.49E-04 1.07E-02 4.31 E-03 1.04E-02 1.42E-02 8.26E-04 1.48E-03 7.24E-04 1.82E-03 1.36E-03 6*88E-04 7.31 E-04 1.63E-02 6.82E-03 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 RU-106 + 1.45E-01 + -2.70E-03 + 0.00E+00 + 3.49E-04 + -1.14E-04 + 4.32E-04 + -1.95E-04 + -1.23E-04 + O.OOE+00 + 0.OOE+00 + 0.OOE+00 + 2.OOE-02 2.15E-02 7.62E-04 2.88E-03 5.03E-04 1.12E-03 8.26E-04 5.22E-04 4.38E-04 1.44E-02 5.50E-03 1.38E-02 1.56E-02 1.27E-03 4.60E-03 7.82E-04 1.68E-03 1.30E-03 8.31 E-04 7.30E-04 2.41 E-02 9.16E-03 Location and Quarter Station 6 3rd 0 09 [Nu-ciide RQ Activity mEr-rorI0 DA I Location and Quarter Station 6 4th Q 09 u-ciiclde RQ Activity Eror MDA-BE-7 + 9.32E-02 + 1.41 E-02 8.30E-03 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA 40 RU-1 06 + 1.56E-01 5.67E-04 -6.64E-05 0.OOE+00 -4.41 E-05 -6.73E-04 -2.41 E-04 -2.18E-04 -7.12E-05 -3.31 E-03 -1.17E-03 + + + + + +. + + + + + 2.01 E-02 6.83E-03 6.15E-04 3.58E-03 4.90E-04 1.82E-03 1.01 E-03 6.23E-04 5.70E-04 1.61 E-02 4.86E-03 1.22E-02 1.29E-02 9.94E-04 5.97E-03 7.87E-04 2.82E-03 1.60E-03 9.84E-04 9.20E-04 2.53E-02 7.69E-03 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-1 34 CS-1 37 BALA 40 RU-106 4.97E-04 + 8.77E-05 + -4.50E-04 + 1.38E-04 + 0.OOE+00 + 0.00E+00 + -1.54E-06 + O.OOE+00 + -1.82E-03 + -3.38E-05 + 5.31 E-03 4.47E-04 3.04E-03 3.84E-04 1.84E-03 7.80E-04 3.32E-04 3.88E-04 1.42E-02 3.56E-03 9.88E-03 7.10 E-04 4.85E-03 5.75E-04 3.07E-03 1.30E-03 5.45E-04 6.46E-04 2.26E-02 5.85E-03 RQ = Results Qualifier. If blank, result is less than detection limit. If '"+, result is above detection limit. 1 st Q 1/1/09 to 3/31/09 - 2nd 0 3/31/09 to 6/30/09 - 3rd Q 6/30/09 to 9/29/09 - 4th Q 9/29/09 to 12/29/09 Page 2 of 6

TABLE A-3.1 GAMMA SPECTROMETRY RESULTS OF AIR PARTICULATE FILTERS Results in pCi/cubic meter, results decay corrected for decay during sample collection period Location and Quarter Station 7 1st Q09 [Nuclide RO Acifvity Error MDA--{ BE-7 + 1.30E-01 + 1.72E-02 9.26E-03 K-40 2.95E-04 + 4.96E-03 1.04E-02 MN-54 -2.93E-04 + 6.55E-04 1.OOE-03 FE-59 0.OOE+00 + 3.32E-03 5.54E-03 CO-60 0.OOE+00 + 1.66E-04 2.77E-04 ZN-65 0.OOE+00 + 2.07E-03 3.44E-03 ZRNB-95 3.85E-04 + 8.65E-04 1.32E-03 CS-134 1.47E-05 + 3.80E-04 6.20E-04 CS-137 -2.39E-04 + 5.54E-04 8.49E-04 BALA140 0.OOE+00 + 3.58E-03 5.97E-03 RU-106 0.OOE+00 + 5.36E-03 8.94E-03 Location and Quarter Station 7 2nd Q 09 FNuclide RQ Activity . Error MDA ] BE-7 + 1.80E-01 + 2.01E-02 1.06E-02 K-40 -1.79E-03 + i.18E-02 1.29E-02 MN-54 7.32E-05 + 4.90E-04 7.81 E-04 FE-59 -4.08E-05 + 2.93E-03 4.81 E-03 CO-60 8.32E-05 + 5.99E-04 9.56E-04 ZN-65 -1.15E-05 + 1.47E-03 2.41E-03 ZRNB-95 4.82E-05 + 7.46E-04 1.21 E-03 CS-1 34 2.08E-06 + 4.56E-04 7.50E-04 CS-137 1.40E-04 + 5.06E-04 7.94E-04 BALA140 -8.11E-05 + 7.80E-03 1.28E-02 RU-106 -3.76E-04 + 4.05E-03 6.54E-03 Location and Quarter Station 7 3rd Q 09 Location and Quarter Station 7 4th Q 09 [Niiclide RQ Activity -Error IM D-A Nuclide RQ Activijy Error MDA BE-7 K-40 MN-54 FE-59 C0-60 ZN-65 ZRNB-95 CS-134 CS-1 37 BALA 40 RU-1 06 + 1.78E-01 + -5.97E-03 + -1.40E-05 + -1.60E-04 + 4.53E-05 + O.OOE+00 + -5.54E-05 + O.OOE+00 + -6.59E-05 + O.OOE+00 + 9.46E&04 + 2.07E-02 2.31 E+00 5.38E-04 3.45E-03 5.03E-04 2.42E-03 1.01 E-03 6.47E-04 5.26E-04 1.98E-02 4.64E-03 1.09E-02 1.56E-02 8.80E-04 5.62E-03 8.09E-04 4.03E-03 1.65E-03 1.08E-03 8.47E-04 3.31 E-02 7.37E-03 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 RU-106 + 1.OOE-01 3.80E-03 O.OOE+00 O.OOE+00 1.60E-04 -3.38E-04 1.19 E-04 -9.86E-06 -6.87E-05 -3.10 E-04 0.OOE+00 + + + + + + + + + + + 1.39E-02 5.91 E-03 2.94E-04 7.89E-04 3.94E-04 1.19E-03 6.56E-04 3.31 E-04 3.09E-04 1.26E-02 4.69E-03 6.58E-03 9.88E-03 4.90E-04 1.31 E-03 5.83E-04 1.86E-03 1.04E-03 5.42E-04 4.85E-04 2.07E-02 7.81 E-03 I II I I I I I I I I1 U Location and Quarter Station 8 1st Q 09 Niuclide RQ Activity Error MDA Location and Quarter Station 8 2nd Q 09 FNucilide R Aciiviti Error MDA I BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 RU-106 + 1.09E-01 + -6.01 E-03 + 1.19E-04 + -1.02E-03 + 0.00E+00 + 3.37E-04 + -2.71 E-04 + -4.75E-05 + 1.17E-05 + 1.33E-03 + 4.44E-04 + 1.62E-02 1.36E-01 4.76E-04 3.23E-03 1.66E-04 1.15E-03 8.87E-04 3.91 E-04 4.74E-04 1.18E-02 4.36E-03 9.76E-03 1.54E-02 7.41 E-04 4.96E-03 2.77E-04 1.76E-03 1.39E-03 6.28E-04 7.77E-04 1.89E-02 7.05E-03 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 RU-106 + 1.53E-01 + -5.99E-03 + 2.03E-06 + 9.86E-04 + -1.51 E-05 + 2.99E-04 + O.OOE+00 + 7.45E-06 + O.OOE+00 + 3.44E-05 + 2.54E-04 + 1.91 E-02 5.34E+00 4.54E-04 2.84E-03 4.86E-04 1.28E-03 8.93E-04 5.02E-04 6.66E-04 9.89E-03 4.48E-03 1.11E-02 1.47E-02 7.45E-04 4.28E-03 7.94E-04 2.OOE-03 1.49E-03 8.23E-04 1.11E-03 1.63E-02 7.30E-03 Location and Quarter Station 8 3rd Q 09 FNiuclide RQ Aciivity Error. iDA 1 Location and Quarter Station 8 4th 0 09 FNuclidie RQ Ac-1V-0-it Er-ror MDA7 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA1 40 RU-106 + 1.66E-01 + -6.57E-04 + 6.17E-05 + O.OOE+00 + O.OOE+00 + 3.08E-04 + -2.56E-04 + 1.39E-05 + -5.85E-05 + -4.80E-03 + -1.51 E-04 + 2.19 E-02 9.11 E-03 5.50E-04 3.59E-03 5.74E-04 1.12E-03 9.38E-04 4.86E-04 5.27E-04 1.46E-02 5.34E-03 1.44E-02 1.39E-02 8.86E-04 5.99E-03 9.57E-04 1.73E-03 1.47E-03 7.95E-04 8.51 E-04 2.22E-02 8.75E-03 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 RU-106 + 8.89E-02 + 9.49E-04 + 2.04E-04 + 0.OOE+00 + 9.43E-05 + -9.40E-05 + 2.15E-04 + -9.86E-05 + -9.51 E-05 + 2.43E-03 + 7.54E-04 + 1.35E-02 4.87E-03 3.59E-04 8.22E-04 3.62E-04 8.68E-04 7.15E-04 4.18E-04 4.11E-04 1.03E-02 3.48E-03 7.33E-03 9.11E-03 5.14E-04 1.37E-03 5.54E-04 1.39E-03 1.11E-03 6.66E-04 6.51 E-04 1.55E-02 5.50E-03 I I I RQ = Results Qualifier. If blank, result is less than detection limit. It "+", result is above detection limit. 1 st Q 1/1/09 to 3/31/09 - 2nd Q 3/31/09 to 6/30/09 - 3rd Q 6/30/09 to 9/29/09 - 4th Q 9/29/09 to 12/29/09 Page 3 of 6

TABLE A-3.1 GAMMA SPECTROMETRY RESULTS OF AIR PARTICULATE FILTERS Results in pCi/cubic meter, results decay corrected for decay during sample collection period Location and Quarter Station 9 1st Q 09 [Niuclide RO Activity Error MDA 7 BE-7 + 9.95E-02 + 1.55E-02 9.20E-03 K-40 -2.65E-03 + 1.82E-02 1.41 E-02 MN-54 2.47E-05 + 4.92E-04 8.01 E-04 FE-59 -7.74E-04 + 2.96E-03 4.59E-03 CO-60 9.02E-05 + 6.04E-04 9.63E-04 ZN-65 0.00E+00 + 1.20E-03 1.99E-03 ZRNB-95 2.92E-04 + 8.10E-04 1.25E-03 CS-134 -1.10E-04 + 4.37E-04 6.90E-04 CS-137 -4.36E-05 + 5.05E-04 8.19E-04 BALA140 6.11E-04 + 1.18E-02 1.91 E-02 RU-106 -4.30E-04 + 4.77E-03 7.73E-03 Location and Quarter Station 9 3rd Q 09 NIuclide RQ Activity Error MDA ] BE-7 + 1.82E-01 + 2.15E-02 1.18E-02 K-40 -5.99E-03 + 5.06E+00 1.50E-02 MN-54 3.55E-04 + 5.26E-04 7.47E-04 FE-59 1.18E-03 + 2.63E-03 3.75E-03 CO-60 6.03E-05 + 2.42E-04 3.46E-04 ZN-65 1.34E-05 + 7.16E-04 1.17E-03 ZRNB-95 -1.72E-04 + 8.33E-04 1.32E-03 CS-134 0.OOE+00 + 7.66E-04 1.28E-03 CS-137 6.24E-06 + 5.10E-04 8.37E-04 BALA140 2.39E-03 + 1.17E-02 1.79E-02 RU-106 1.40E-03 + 4.15E-03 6:39E-03 Location and Quarter Station 21 1st 0 09 [Nicliide RQ Activity Error MDA 7 BE-7 + 1.02E-01 + 1.59E-02 1.OOE-02 K-40 3.75E-04 + 6.89E-03 1.30E-02 MN-54 2.61 E-04 + 4.24E-04 5.92E-04 FE-59 -7.61 E-04 + 2.93E-03 4.52E-03 CO-60 2.09E-04 + 5.27E-04 7.85E-04 ZN-65 0.OOE+00 + 2.07E-03 3.44E-03 ZRNB-95 1.31 E-06 + 7.54E-04 1.24E-03 CS-134 7.08E-07 + 4.15E-04 6.81 E-04 CS-137 -8.99E-05 + 4.51 E-04 7.14E-04 BALA140 1.73E-03 + 1.12E-02 1.77E-02 RU-106 1.09E-03 + 4.46E-03 7.02E-03 Location and Quarter Station 21 3rd Q 09 [Nuclide RQ Activity Error MDA ] BE-7 + 2.26E-01 + 2.33E-02 1.07E-02 K-40 9.59E-04 + 6.92E-03 1.29E-02 MN-54 2.55E-04 + 5.23E-04 7.78E-04 FE-59 1.71 E-03 + 2.64E-03 3.49E-03 CO-60 0.OOE+00 + 5.75E-04 9.58E-04 ZN-65 -4.80E-04 + 1.76E-03 2.77E-03 ZRNB-95 9.14E-06 + 6.46E-04 1.06E-03 CS-134 -1.18E-04 + 5.13E-04 8.17E-04 CS-1 37 -8.78E-05 + 4.56E-04 7.24E-04 BALA140 4.51 E-03 + 1.85E-02 2.90E-02 RU-106 -1.07E-03 + 5.16E-03 8.23E-03 Location and Quarter Station 9 2nd Q 09 [Niucide RQ Activity Error MDA BE-7 + 1.62E-01 + 1.95E-02 1.07E-02 K-40 -6.36E-04 + 8.39E-03 1.31 E-02 MN-54 0.OOE+00 + 5.39E-04 8.99E-04 FE-59 0.OOE+00 + 3.32E-03 5.53E-03 CO-60 2.02E-04 + 4.09E-04 5.68E-04 ZN-65 1.40E-05 + 1.36E-03 2.23E-03 ZRNB-95 -2.61 E-04 + 9.91 E-04 1.57E-03 CS-134 4.61 E-06 + 3.85E-04 6.31 E-04 CS-137 -2.55E-04 + 5.84E-04 8.99E-04 BALA140 -2.49E-04 + 1.03E-02 1.68E-02 RU-106 4.90E-04 + 2.89E-03 4.54E-03 Location and Quarter Station 9 4th Q 09 [Nuiclide RQ Activity Error MDA ] BE-7 + 1.04E-01 + 1.46E-02 8.39E-03 K-40 -1.58E-03 + 9.33E-03 9.19E-03 MN-54 4.11 E-05 + 3.36E-04 5.38E-04 FE-59 1.08E-04 + 1.58E-03 2.53E-03 CO-60 -3.64E-06 + 3.36E-04 5.51 E-04 ZN-65 0.OOE+00 + 1.58E-03 2.63E-03 ZRNB-95 8.44E-05 + 7.19E-04 1.16E-03 CS-134 -1.94E-04 + 4.70E-04 7.35E-04 CS-137 -1.04E-04 + 3.47E-04 5.38E-04 BALA140 7.21 E-03 + 1.04E-02 1.31 E-02 RU-106 2.07E-03 + 3.37E-03 4.92E-03 Location and Quarter Station 21 2nd Q 09 [Nuclide RQ Activity Error MDA ] BE-7 + 2.13E-01 + 2.14E-02 8.78E-03 K-40 -2.52E-03 + 1.39E-02 1.22E-02 MN-54 -2.46E-05 + 3.73E-04 6.03E-04 FE-59 0.OOE+00 + 9.OOE-04 1.50E-03 CO-60 0.OOE+00 + 1.66E-04 2.77E-04 ZN-65 1.60E-04 + 1.07E-03 1.70E-03 ZRNB-95 8.06E-05 + 6.27E-04 1.OOE-03 CS-134 -1.34E-04 + 5.18E-04 8.22E-04 CS-137 2.83E-05 + 4.17E-04 6.77E-04 BALA140 -2.58E-04 + 8.84E-03 1.44E-02 RU-106 9.86E-04 + 3.61E-03 5.60E-03 Location and Quarter Station 21 4th Q 09 [Nuciide RQ Activity Error MEWA] BE-7 + 1.13E-01 + 1.45E-02 6.61E-03 K-40 1.46E-03 + 4.47E-03 8.37E-03 MN-54 -5.26E-05 + 3.67E-04 5.86E-04 FE-59 0.OOE+00 + 7.74E-04 1.29E-03 CO-60 3.75E-04 + 4.79E-04 6.58E-04 ZN-65 1.32E-04 + 8.37E-04 1.32E-03 ZRNB-95 1.15E-04 + 6.45E-04 1.02E-03 CS7134 1.07E-04 + 3.76E-04 5.92E-04 CS-137 -4.20E-05 + 3.96E-04 6.40E-04 BALA140 -2.68E-03 + 1.11E-02 1.71 E-02 RU-106 -6.15E-04 + 3.40E-03 5.41 E-03 RQ = Results Qualifier. If blank, result is less than detection limit, If "+", result is above detection limit. 1 st Q 1/1/09 to 3/31/09 - 2nd 0 3/31/09 to 6/30/09 - 3rd Q 6/30/09 to 9/29/09 - 4th 0 9/29/09 to 12/29/09 Page 4 of 6

TABLE A-3.1 GAMMA SPECTROMETRY RESULTS OF AIR PARTICULATE FILTERS Results in pCi/cubic meter, results decay corrected for decay during sample collection period Location and Quarter Station 23 1st Q 09 [NWuclide RQ Activity Error MDA Location and Quarter Station 23 2nd Q 09 fNuclide RQ Activity Error MDA-BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 RU-106 + 1.05E-01 + -6.01 E-03 + -8.46E-06 + 7.93E-04 + 0.OOE+00 + 5.06E-05 + 2.29E-04 + 1.41 E-04 + 2.27E-05 + 1.39E-03 + -8.16E-04 + 1.66E-02 1.92E-01 4.65E-04 3.14E-03 1.66E-04 1.13E-03 7.85E-04 4.67E-04 4.01 E-04 9.01 E-03 4.17E-03 1.13E-02 1.98E-02 7.62E-04 4.89E-03 2.77E-04 1.85E-03 1.22E-03 7.33E-04 6.51 E-04 1.41 E-02 6.62E-03 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA 40 RU-106 + 1.77E-01 + -2.62E-03 + -1.90E-04 + 5.83E-04 + 5.39E-05 + 0.OOE+00 + -1.81 E-04 + -5.07E-05 + -4.78E-05 + 1.59E-04 + 1.96E-03 + 1.98E-02 1.76E-02 6.21 E-04 2.95E-03 5.26E-04 1.19E-03 8.1OE-04 3.39E-04 4.52E-04 1.05E-02 3.91 E-03 9.39E-03 1.38E-02 9.70E-04 4.63E-03 8.45E-04 1.99E-03 1.28E-03 5.41 E-04 7.29E-04 1.72E-02 5.79E-03 Location and Quarter Station 23 3rd Q 09 [Nuclide RO Activity Error MDA7 Location and Quarter Station 23 4th Q 09 FNuclide RQ Activity Error MDA--j BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-1 34 CS-137 BALA140 RU-106 + 1.87E-01 + -6.46E-03 + 0.OOE+00 + 0.OOE+00 + 0.OOE+00 + -6.74E-04 + 9.89E-05 + -3.40E-04 + 1.31 E-04 + 0.OOE+00 + 6.62E-04 + 2.18E-02 1.83E-01 6.28E-04 3.70E-03 1.67E-04 1.78E-03 9.26E-04 6.54E-04 4.58E-04 2.22E-02 4.09E-03 1.18E-02 1.43E-02 1.05E-03 6.17E-03 2.78E-04 2.76E-03 1.49E-03 1.01 E-03 7.13E-04 3.70E-02 6.52E-03 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-1 34 CS-1 37 BALA 40 RU-1 06 + 9.90E-02 + 1.88E-03 + 9.03E-05 + 2.76E-04 + 2.33E-04 + 3.27E-04 + -1.26E-04 + -7.30E-05 + 1.22E-04 + -2.02E-03 + 5.15E-04 + 1.46E-02 5.50E-03 4.05E-04 2.17E-03 3.86E-04 1.07E-03 6.48E-04 4.06E-04 3.39E-04 1.27E-02 3.54E-03 8.39E-03 9.93E-03 6.35E-04 3.44E-03 5.27E-04 1.64E-03 1.02E-03 6.50E-04 5.15E-04 2.OOE-02 5.66E-03 I I I1 I I I I I I I I I I I I i I I I Location and Quarter Station 40 1st Q 09 [Nuiclide RQ Activity Error MDA7 BE-7 + 1.05E-01 + 1.66E-02 1.13E-02 K-40 -6.01 E-03 + 1.92E-01 1.98E-02 MN-54 -8.46E-06 + 4.65E-04 7.62E-04 FE-59 7.93E-04 + 3.14E-03 4.89E-03 CO-60 0.OOE+00 + 1.66E-04 2.77E-04 ZN-65 5.06E-05 + 1.13E-03 1.85E-03 ZRNB-95 2.29E-04 + 7.85E-04 1.22E-03 CS-134 1.41 E-04 + 4.67E-04 7.33E-04 CS-137 2.27E-05 + 4.01E-04 6.51E-04 BALA140 1.39E-03 + 9.01E-03 1.41 E-02 RU-106 -8.16E-04 + 4.17E-03 6.62E-03 Location and Quarter Station 40 3rd Q 09 Niiuclide RQ Activity Error MDA ] BE-7 + 1.61 E-01 + 2.08E-02 1.28E-02 K-40 -1.18E-03 + 9.83E-03 1.30E-02 MN-54 -1.45E-04 + 6.28E-04 9.95E-04 FE-59 2.76E-05 + 3.58E-03 5.87E-03 CO-60 0.OOE+00 + 1.67E-04 2.78E-04 ZN-65 -3.45E-04 + 1.63E-03 2.59E-03 ZRNB-95 -3.80E-04 + 1.26E-03 2.OOE-03 CS-134 0.OOE+00 + 1.10E-03 1.83E-03 CS-137 0.OOE+00 + 6.48E-04 1.08E-03 BALA140 0.OOE+00 + 4.45E-02 , 7.41 E-02 RU-106 -1.51E-03 + 4.46E-03 6.91E-03 Location and Quarter Station 40 2nd 0 09 [Nuclide RQ Activity Error MDA BE-7 + 1.78E-01 + 2.OOE-02 9.61 E-03 K-40 -6.OOE-03 + 2.40E-02 9.28E-03 MN-54 6.58E-05 + 4.46E-04 7.09E-04 FE-59 0.OOE+00 + 3.33E-03 5.55E-03 CO-60 0.OOE+00 + 1.66E-04 2.77E-04 ZN-65 0.OOE+00 + 1.19E-03 1.99E-03 ZRNB-95 -2.54E-06 + 7.43E-04 1.22E-03 CS-134 0.OOE+00 + 7.24E-04 1.21E-03 CS-137 -2.01 E-05 + 4.17E-04 6.78E-04 BALA140 0.OOE+00 + 3.60E-03 6.01 E-03 RU-1 06 -1.01 E-03 + 4.34E-03 6.85E-03 Location and Quarter Station 40 4th Q 09 [Nu-cliile RQ AcTivity Error MDA-] BE-7 + 9.42E-02 + 1.45E-02 8.78E-03 K-40 9.44E-04 + 4.68E-03 8.87E-03 MN-54 -1.20E-04 + 5.04E-04 7.98E-04 FE-59 0.00E+00 + 7.98E-04 1.33E-03 CO-60 2.93E-04 + 3.94E-04 5.21 E-04 ZN-65 0.OOE+00 + 9.26E-04 1.54E-03 ZRNB-95 -1.69E-04 + 7.56E-04 1.20E-03 CS-134 1.22E-05 + 3.22E-04 5.27E-04 CS-137 2.49E-05 + 2.74E-04 4.40E-04 BALA140 0.OOE+00 + 1.83E-02 3.06E-02 RU-1 06 5.02E-04 + 3.36E-03 5.38E-03 RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. 1st Q 1/1/09 to 3/31/09 - 2nd Q 3/31/09 to 6/30/09 - 3rd Q 6/30/09 to 9/29/09 - 4th Q 9/29/09 to 12/29/09 Page 5 of 6

TABLE A-3.1 GAMMA SPECTROMETRY RESULTS OF AIR PARTICULATE FILTERS Results in pCi/cubic meter, results decay corrected for decay during sample collection period Location and Quarter Station 48 1st Q 09 [Nuclide RO Activity Error MDA-] Location and Quarter Station 48 2nd Q 09 [Nuclide RQ Activity E-lrror MDA A BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-1 34 CS-1 37 BALA140 RU-106 + 9.63E-02 + -6.01 E-03 + 4.03E-05 + 0.OOE+00 + -1.73E-07 + -5.23E-04 + -7.46E-06 + 0.OOE+00 + -5.08E-05 + O.OOE+O0 + 2.59E-04 + 1.55E-02 1.36E-01 6.02E-04 3.38E-03 4.48E-04 1.64E-03 6.84E-04 7.25E-04 5.45E-04 3.78E-03 4.79E-03 9.51 E-03 1.54E-02 9.80E-04 5.63E-03 7.34E-04 2.57E-03 1.12E-03 1.21 E-03 8.83E-04 6.29E-03 7.81 E-03 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 RU-106 + 1.34E-01 + -5.86E-03 + -1.13E-05 + 0.OOE+00 + -2.06E-06 + -8.58E-05 + 1.38E-05 + 4.63E-05 + 1.26E-04 + 0.OOE+00 + 9.66E-04 + 1.73E-02 4.56E-01 4.49E-04 9.02E-04 5.28E-04 1.37E-03 6.83E-04 3.95E-04 4.06E-04 1.53E-02 4.16E-03 8.59E-03 1.28E-02 7.34E-04 1.50E-03 8.67E-04 2.22E-03 1.12E-03 6.35E-04 6.24E-04 2.54E-02 6.55E-03 Location and Quarter Station 48 3rd Q 09 [Nuclide RQ Activity Error MDA:I BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 RU-106 + 1.70E-01 + 3.56E-03 + 0.OOE+00 + 8.18E-04 + 0.OOE+00 + -3.48E-04 + 8.07E-05 + 4.67E-05 + 1.11E-04 + 0.OOE+00 + -4.92E-05 + 2.17E-02 6.53E-03 4.02E-04 3.51 E-03 5.91 E-04 1.22E-03 7.88E-04 4.13E-04 4.88E-04 6.68E-03 4.07E-03 1.18E-02 1.16E-02 6.70E-04 5.47E-03 9.84E-04 1.87E-03 1.27E-03 6.66E-04 7.70E-04 1.11E-02 6.68E-03 Location and Quarter Station 57 1stQ 09 [Nucilide RQ Activity Error MDA---7 Location and Quarter Station 48 4th Q 09 lNuciiaie RQ Activity-" Error iMDA7 BE-7 + 1.01 E-01 + 1.40E-02 7.31 E-03 K-40 -2.52E-03 + 1.48E-02 8.96E-03 MN-54 -7.05E-06 + 2.73E-04 4.46E-04 FE-59 -6.83E-04 + 2.37E-03 3.62E-03 CO-60 -7.22E-05 + 4.09E-04 6.45E-04 ZN-65 0.OOE+00 + 9.1OE-04 1.52E-03 ZRNB-95 5.05E-06 + 6.72E-04 1.10E-03 CS-134 -1.77E-05 + 3.65E-04 5.96E-04 CS-137 -7.27E-05 + 3.61E-04 5.72E-04 BALA140 0.OOE+00 + 4.04E-03 6.73E-03 RU-106 -6.10E-04 + 3.66E-03 5.86E-03 Location and Quarter Station 57 2nd Q 09 rNucliie RQ "Ac-tivity, " Error MDA ] BE-7 + 1.67E-01 + 2.01E-02 1.15E-02 K-40 -6.OOE-03 + 1.35E-01 1.54E-02 MN-54 4.15E-05 + 5.56E-04 9.01 E-04 FE-59 0.OOE+00 + 3.33E-03 5.55E-03 CO-60 -1.67E-04 + 5.44E-04 8.32E-04 ZN-65 -3.41 E-04 + 1.38E-03 2.16E-03 ZRNB-95 -6.68E-05 + 6.05E-04 9.69E-04 CS-134 3.75E-05 + 5.37E-04 8.75E-04 CS-137 4.96E-05 + 4.42E-04 7.11E-04 BALA140 4.15E-05 + 9.48E-03 1.56E-02 RU-106 2.OOE-03 + 4.67E-03 7.14E-03 Location and Quarter Station 57 4th Q 09 [Nu-ciile RQ Activity---Errorm, MDA ] BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-1 34 CS-1 37 BALA1 40 RU-106 + 9.24E-02 + -2.03E-03 + 0.OOE+00 + 3.21 E-04 + 1.46E-04 + 8.29E-05 + 0.OOE+00 + -6.88E-06 + 0.OOE+00 + 0.OOE+00 + 0.OOE+00 + 1.60E-02 1.31 E-02 5.09E-04 1.91 E-03 5.02E-04 1.42E-03 7.61 E-04 4.69E-04 6.95E-04 3.95E-03 4.90E-03 1.15E-02 1.35E-02 8.48E-04 2.94E-03 7.64E-04 2.30E-03 1.27E-03 7.69E-04 1.16E-03 6.59E-03 8.16E-03 Location and Quarter Station 57 3rd Q 09 [N*uclde RQ Activity Error, MDA 7 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA 40 RU-1 06 + 1.80E-01 + -3.87E-03 + 1.26E-04 + 0.OOE+00 + -1.57E-04 + -1.57E-04 + -1.50E-04 + -1.20E-06 + 2.04E-04 + 1.11E-02 + -6.63E-04 + 2.20E-02 2.58E-02 6.14E-04 1.07E-03 5.30E-04 1.15E-03 1.19E-03 4.11 E-04 4.05E-04 1.84E-02 4.76E-03 1.18E-02 1.25E-02 9.75E-04 1.78E-03 8.11E-04 1.83E-03 1.92E-03 6.77E-04 5.93E-04 2.51 E-02 7.66E-03 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 RU-106 + 9.29E-02 + 3.50E-03 + -1.16E-05 + -7.99E-04 + 7.85E-05 + -1.39E-04 + 0.OOE+00 + 0.OOE+00 + 1.OOE-05 + -5.47E-03 + 9.55E-04 + 1.42E-02 5.48E-03 4.35E-04 2.83E-03 3.50E-04 9.84E-04 6.37E-04 4.19E-04 3.26E-04 1.71 E-02 3.43E-03 8.22E-03 9.26E-03 7.11E-04 4.38E-03 5.41 E-04 1.57E-03 1.06E-03 6.99E-04 5.33E-04 2.61 E-02 5.36E-03 RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. 1st Q 1/1/09 to 3/31/09 - 2nd Q 3/31/09 to 6/30/09 - 3rd 0 6/30/09 to 9/29/09 - 4th 0 9/29/09 to 12/29/09 Page 6 of 6

TABLE A-3.2 GAMMA SPECTROMETRY RESULTS OF AIR PARTICULATE FILTERS

SUMMARY

Results in pCi per cubic meter, corrected for decay during collection period Average Activity Activity

Low, Activity Average Number of Number of High MDA Samples Positive IDs Nuclide BALA140 Ind BALA140 Cntl BE-7 Ind BE-7 Cntl CO-60 Ind CO-60 CntI CS-134 Ind CS-134 CntI CS-137 Ind CS-1 37 Cntl FE-59 Ind FE-59 Cnti K-40 Ind K-40 Cntl MN-54 Ind MN-54 Cntl RU-106 Ind RU-1 06 Cntl ZN-65 Ind ZN-65 CntI ZRNB-95 Ind ZRNB-95 CntI 7.99E-05

-5.47E-03 2.49E-03 -2.49E-04 1.37E-01 8.24E-02 1.37E-01 9.95E-02 5.30E-05 -1.67E-04 8.72E-05 -3.64E-06 -1.30E-05 -3.40E-04 -7.49E-05 -1.94E-04 3.04E-06 -2.39E-04 -9.89E-05 -2.55E-04 1.74E-04 -1.34E-03 1.28E-04 -7.74E-04 -2.03E-03 -6.46E-03 -2.71 E-03 -5.99E-03 1.88E-05 -2.93E-04 1.05E-04 0.OOE+00 6.97E-06 -1.55E-03 8.84E-04 -4.30E-04 -7.96E-05 -6.74E-04 6.87E-06 0.OOE+00 -1.37E-06 -3.80E-04 -1.41 E-05 -2.61 E-04 1.11E-02 1.96E-02 7.21 E-03 1.67E-02 2.26E-01 9.83E-03 1.82E-01 1.OOE-02 3.75E-04 6.87E-04 2.02E-04 6.07E-04 1.49E-04 7.77E-04 4.61 E-06 8.33E-04 2.04E-04 7.21 E-04 6.24E-06 7.73E-04 1.71E-03 4.13E-03 1.18E-03 4.10E-03 3.80E-03 1.25E-02 -6.36E-04 1.28E-02 2.61 E-04 7.98E-04 3.55E-04 7.46E-04 2.OOE-03 7.OOE-03 2.07E-03 5.90E-03 4.32E-04 2.22E-03 1.40E-05 2.01 E-03 3.85E-04 1.25E-03 2.92E-04 1.32E-03 0 0 44 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I I I i I I I I I I I I I I I I I Ind = Indicator Stations Cntl = Control Stations Page 1 of 1

TABLE A-4.1 GAMMA SPECTROMETRY RESULTS OF 1-131 ON CHARCOAL FILTERS Results in pCi/cubic meter, corrected for decay during collection period 1 /U/6UUd0 1/6/2009 1/13/2009 1/20/2009 1/27/2009 1/O/2U00 1/13/2009 1/20/2009 1/27/2009 2/3/2009 U.UUt"+UU -2.58E-03 3.20E-04 9.97E-03 -1.29E-04 + +( +m -+ 1.1515r--Uie 1.05E-02 6.77E-03 1.06E-02 1.06E-02 1.68E-02 1.10E-02 1.54E-02 1.74E-02 0.OOE+00 1.12E-03 -1.35E-03 0.OOE+00 _+ + + +. 1.1 41-Uz 1.12E-02 9.26E-03 1.05E-02 1.54E-02 1.tib--UZ 1.86E-02 1.50E-02 1.70E-02 2.56E-02 2/3/2009 - 2/10/2009 -3.97E-04 + 8.30E-03 1.36E-02 O.OOE+00 + 9.OOE-03 1.50E-02 2/10/2009 - 2/17/2009 -2.21E-03 + 9.64E-03 1.54E-02 -7.17E-04 + 1.10E-02 1.79E-02 2/17/2009 - 2/24/2009 4.65E-03 + 7.80E-03 1.15E-02 -5.32E-04 + 8.92E-03 1.45E-02 2/24/2009 - 3/3/2009 O.OOE+00 + 1.05E-02 1.75E-02 2.69E-04 + 9.81 E-03 1.61 E-02 3/3/2009-3/10/2009 -2.23E-03 + 1.10E-02 1.76E-02 1.34E-03 + 9.47E-03 1.53E-02 3/10/2009 - 3/17/2009 2.33E-03 + 1.04E-02 1.67E-02 1.02E-03 + 8.94E-03 1.45E-02 3/17/2009-3/24/2009 O.OOE+00 + 1.02E-02 1.70E-02 -3.58E-03 + 1.30E-02 2.08E-02 3/24/2009 - 3/31/2009 -1.91 E-04 + 1.01 E-02 1.65E-02 -7.46E-04 + 9.02E-03 1.46E-02 3/31/2009 - 4/7/2009 5.93E-04 + 1.04E-02 1.70E-02 4.50E-04 + 1.06E-02 1.73E-02 4/7/2009 - 4/14/2009 -1.32E-03 + 7.72E-03 1.23E-02 1.52E-03 + 9.35E-03 1.50E-02 4/14/2009 - 4/21/2009 4.32E-04 + 8.43E-03 1.38E-02 9.31 E-04 + 9.95E-03 1.62E-02 4/21/2009 - 4/28/2009 4.37E-03 + 8.03E-03 1.21 E-02 -1.29E-03 + 1.01 E-02 1.63E-02 4/28/2009 - 5/5/2009 2.22E-04 + 9.34E-03 1.53E-02 2.79E-03 + 9.41 E-03 1.49E-02 5/5/2009-5/12/2009 -3.05E-03 + 9.98E-03 1.58E-02 2.13E-03 + 8.26E-03 1.30E-02 5/12/2009-5/19/2009 -1.06E-03 + 9.76E-03 1.58E-02 3.30E-03 + 9.68E-03 1.52E-02 5/19/2009-5/26/2009 -3.15E-04 + 9.01E-03 1.47E-02 2.06E-03 + 9.70E-03 1.55E-02 5/26/2009-6/2/2009 -5.12E-05 + 1.OOE-02 1.65E-02 -1.80E-03 + 1.09E-02 1.76E-02 6/2/2009 - 6/9/2009 -2.54E-04 + 9.35E-03 1.53E-02 -2.13E-04 + 9.83E-03 1.61 E-02 6/9/2009-6/16/2009 3.95E-03 + 8.OOE-03 1.21E-02 -2.82E-03 + 1.10E-02 1.76E-02 6/16/2009 - 6/23/2009 -3.34E-03 + 9.93E-03 1.56E-02 O.OOE+00 + 9.68E-03 1.61 E-02 6/23/2009-6/30/2009 -1.78E-04 + 7.92E-03 1.30E-02 O.OOE+00 + 7.98E-03 1.33E-02 6/30/2009-7/7/2009 1.53E-03 + 9.06E-03 1.46E-02 -4.72E-04 + 9.76E-03 1.59E-02 7/7/2009'- 7/14/2009 2.50E-03 + 9.29E-03 1.47E-02 1.89E-04 + 9.47E-03 1.55E-02 7/14/2009-7/21/2009 O.OOE+00 + 1.19E-02 1.99E-02 -1.04E-03 + 9.41E-03 1.53E-02 7/21/2009-7/28/2009 2.04E-03 + 1.05E-02 1.68E-02 -4.15E-03 + 1.23E-02 1.96E-02 7/28/2009-8/4/2009 2.41 E-03 + 9.20E-03 1.46E-02 3.25E-04 + 1.03E-02 1.69E-02 8/4/2009 - 8/11/2009 6.69E-04 + 6.80E-03 1.10E-02 7.62E-05 + 7.94E-03 1.30E-02 8/11/2009 - 8/18/2009 7.22E-03 + 9.72E-03 1.44E-02 5.91E-03 + 7.37E-03 1.06E-02 8/18/2009-8/25/2009 4.20E-04 + 9.64E-03 1.58E-02 -1.67E-03 + 9.66E-03 1.55E-02 8/25/2009-9/1/2009 -3.88E-03 + 1.07E-02 1.69E-02 6.37E-03 + 8.58E-03 1.24E-02 9/1/2009 - 9/8/2009 -3.21E-03 + 1.12E-02 1.78E-02 -2.91E-04 + 9.32E-03 1.53E-02 9/8/2009 - 9/15/2009 -2.71 E-03 + 1.07E-02 1.71 E-02 -1.94E-03 + 8.52E-03 1.36E-02 9/15/2009 - 9/22/2009 O.OOE+00 + 1.17E-02 1.94E-02 -3.81E-04 + 9.71E-03 1.59E-02 9/22/2009 - 9/29/2009 -1.58E-04 + 8.97E-03 1.47E-02 -1.97E-04 + 1.03E-02 1.70E-02 9/29/2009 - 10/6/2009 1.07E-04 + 1.03E-02 1.70E-02 O.OOE+00 + 1.39E-02 2.32E-02 10/6/2009 - 10/13/2009 -2.06E-04 + 9.77E-03 1.60E-02 5.73E-03 + 1.09E-02 1.69E-02 10/13/2009 - 10/20/2009 1.58E-03 + 8.80E-03 1.41 E-02 2.32E-03 + 1.05E-02 1.68E-02 10/20/2009 - 10/27/2009 4.27E-03 + 9.20E-03 1.41 E-02 -2.11 E-03 + 1.02E-02 1.63E-02 10/27/2009 - 11/3/2009 8.77E-04 + 1.25E-02 2.04E-02 O.OOE+00 + 1.30E-02 2.17E-02 11/3/2009 - 11/10/2009 1.04E-03 + 8.90E-03 1.44E-02 -7.93E-05 + 9.37E-03 1.54E-02 11/10/2009 - 11/17/2009 -2.84E-03 + 1.20E-02 1.92E-02 5.30E-04 + 1.01E-02 1.64E-02 11/17/2009 - 11/24/2009 -6.99E-04 + 8.43E-03 1.37E-02 1.20E-03 + 7.97E-03 1.28E-02 11/24/2009 - 12/1/2009 1.03E-03 + 9.72E-03 1.57E-02 O.OOE+00 + 1.35E-02 2.24E-02 12/1/2009 - 12/8/2009 -4.71E-03 + 1.30E-02 2.05E-02 O.OOE+00 + 1.30E-02 2.17E-02 12/8/2009 - 12/15/2009 -2.86E-03 + 1.07E-02 1.71E-02 -1.67E-03 + 1.15E-02 1.86E-02 12/15/2009 - 12/22/2009 -9.95E-04 + 9.82E-03 1.59E-02 O.OOE+00 + 9.OOE-03 1.50E-02 12/22/2009 - 12/29/2009 -4.04E-03 + 1.11E-02 1.75E-02 -2.84E-03 + 1.17E-02 1.88E-02 NVS = Valid sample not obtained due to sampler failure. Page 1 of 6

I TABLE A-4.1 GAMMA SPECTROMETRY RESULTS OF 1-131 ON CHARCOAL FILTERS Results in pCi/cubic meter, corrected for decay during collection period 1/6/2009 1/13/2009 1/20/2009 1/27/2009 1/13/2009 1/20/2009 1/27/2009 2/3/2009 -2.58E-03 3.20E-04 9.97E-03 -1.29E-04 +¢ +- 4- +- 1.05E-02 6.77E-03 1.06E-02 1.06E-02 1.68E-02 1.10E-02 1.54E-02 1.74E-02 0.OOE+00 1.12E-03 -1.35E-03 0.OOE+00 + _+ + 1.12E-02 9.26E-03 1.05E-02 1.54E-02 1.86E-02 1.50E-02 1.70E-02 2.56E-02 2/3/2009 - 2/10/2009 -3.97E-04 + 8.30E-03 1.36E-02 0.OOE+00 + 9.OOE-03 1.50E-02 2/10/2009 - 2/17/2009 -2.21E-03 + 9.64E-03 1.54E-02 -7.17E-04 + 1.10E-02 1.79E-02 2/17/2009 - 2/24/2009 4.65E-03 + 7.80E-03 1.15E-02 -5.32E-04 + 8.92E-03 1.45E-02 2/24/2009 - 3/3/2009 0.OOE+00 + 1.05E-02 1.75E-02 2.69E-04 + 9.81 E-03 1.61 E-02 3/3/2009 - 3/10/2009 -2.23E-03 + 1.10E-02 1.76E-02 1.34E-03 + 9.47E-03 1.53E-02 3/10/2009 - 3/17/2009 2.33E-03 + 1.04E-02 1.67E-02 1.02E-03 + 8.94E-03 1.45E-02 3/17/2009 - 3/24/2009 0.OOE+00 + 1.02E-02 1.70E-02 -3.58E-03 + 1.30E-02 2.08E-02 3/24/2009 - 3/31/2009 -1.91 E-04 + 1.01 E-02 1.65E-02 -7.46E-04 + 9.02E-03 1.46E-02 3/31/2009 - 4/7/2009 5.93E-04 +. 1.04E-02 1.70E-02 4.50E-04 + 1.06E-02 1.73E-02 .4/7/2009 - 4/14/2009 -1.32E-03 + 7.72E-03 1.23E-02 1.52E-03 + 9.35E-03 1.50E-02 4/14/2009 - 4/21/2009 4.32E-04 + 8.43E-03 1.38E-02 9.31E-04 + 9.95E-03 1.62E-02 4/21/2009 - 4/28/2009 4.37E-03 + 8.03E-03 1.21 E-02 -1.29E-03 + 1.01 E-02 1.63E-02 4/28/2009 - 5/5/2009 2.22E-04 + 9.34E-03 1.53E-02 2.79E-03 + 9.41 E-03 1.49E-02 5/5/2009 - 5/12/2009 -3.05E-03 + 9.98E-03 1.58E-02 2.13E-03 + 8.26E-03 1.30E-02 .5/12/2009 - 5/19/2009 -1.06E-03 + 9.76E-03 1.58E-02 3.30E-03 + 9.68E-03 1.52E-02 5/19/2009 - 5/26/2009 -3.15E-04 + 9.01E-03 1.47E-02 2.06E-03 + 9.70E-03 1.55E-02 5/26/2009 - 6/2/2009 -5.12E-05 + 1.OOE-02 1.65E-02 -1.80E-03 + 1.09E-02 1.76E-02 6/2/2009 - 6/9/2009 -2.54E-04 + 9.35E-03 1.53E-02 -2.13E-04 + 9.83E-03 1.61E-02 6/9/2009 - 6/16/2009 3.95E-03 + 8.OOE-03 1.21 E-02 -2.82E-03 + 1.10E-02 1.76E-02 6/16/2009 - 6/23/2009 -3.34E-03 + 9.93E-03 1.56E-02 0.OOE+00 + 9.68E-03 1.61 E-02 6/23/2009 - 6/30/2009 -1.78E-04 + 7.92E-03 1.30E-02 0.OOE+00 + 7.98E-03 1.33E-02 6/30/2009 - 7/7/2009 1.53E-03 + 9.06E-03 1.46E-02 -4.72E-04 + 9.76E-03 1.59E-02 7/7/2009 - 7/14/2009 2.50E-03 + 9.29E-03 1.47E-02 1.89E-04 + 9.47E-03 1.55E-02 7/14/2009 - 7/21/2009 0.OOE+00 + 1.19E-02 1.99E-02 -1.04E-03 + 9.41E-03 1.53E-02 7/21/2009 - 7/28/2009 2.04E-03 + 1.05E-02 1.68E-02 -4.15E-03 + 1.23E-02 1.96E-02 7/28/2009 - 8/4/2009 2.41 E-03 + 9.20E-03 1.46E-02 3.25E-04 + 1.03E-02 1.69E-02 8/4/2009 - 8/11/2009 6.69E-04 + 6.80E-03 1.10E-02 7.62E-05 + 7.94E-03 1.30E-02 8/11/2009 - 8/18/2009 7.22E-03 + 9.72E-03 1.44E-02 5.91 E-03 + 7.37E-03 1.06E-02 8/18/2009 - 8/25/2009 4.20E-04 + 9.64E-03 1.58E-02 -1.67E-03 + 9.66E-03 1.55E-02 8/25/2009 - 9/1/2009 -3.88E-03 + 1.07E-02 1.69E-02 6.37E-03 + 8.58E-03 1.24E-02 9/1/2009 - 9/8/2009 -3.21E-03 + 1.12E-02 1.78E-02 -2.91E-04 + 9.32E-03 1.53E-02 9/8/2009 - 9/15/2009 -2.71 E-03 + 1.07E-02 1.71 E-02 -1.94E-03 + 8.52E-03 1.36E-02 9/15/2009 - 9/22/2009 0.OOE+00 + 1.17E-02 1.94E-02 -3.81E-04 + 9.71E-03 1.59E-02 9/22/2009 - 9/29/2009 -1.58E-04 + 8.97E-03 1.47E-02 -1.97E-04 + 1.03E-02 1.70E-02 9/29/2009 - 10/6/2009 1.07E-04 + 1.03E-02 1.70E-02 0.OOE+00 + 1.39E-02 2.32E-02 10/6/2009 - 10/13/2009 -2.06E-04 + 9.77E-03 1.60E-02 5.73E-03 + 1.09E-02 1.69E-02 10/13/2009 - 10/20/2009 1.58E-03 + 8.80E-03 1.41 E-02 2.32E-03 + 1.05E-02 1.68E-02 10/20/2009 - 10/27/2009 4.27E-03 + 9.20E-03 1.41E-02 -2.11E-03 + 1.02E-02 1.63E-02 10/27/2009 - 11/3/2009 8.77E-04 + 1.25E-02 2.04E-02 0.OOE+00 + 1.30E-02 2.17E-02 11/3/2009 - 11/10/2009 1.04E-03 + 8.90E-03 1.44E-02 -7.93E-05 + 9.37E-03 1.54E-02 11/10/2009 - 11/17/2009 -2.84E-03 + 1.20E-02 1.9.2E-02 5.30E-04 + 1.01E-02 1.64E-02 11/17/2009 - 11/24/2009 -6.99E-04 + 8.43E-03 1.37E-02 1.20E-03 + 7.97E-03 1.28E-02 11/24/2009 - 12/1/2009 1.03E-03 + 9.72E-03 1.57E-02 0.OOE+00 + 1.35E-02 2.24E-02 12/1/2009 - 12/8/2009 -4.71E-03 + 1.30E-02 2.05E-02 0.OOE+00 + 1.30E-02 2.17E-02 12/8/2009 - 12/15/2009 -2.86E-03 + 1.07E-02 1.71E-02 -1.67E-03 + 1.15E-02 1.86E-02 12/15/2009 - 12/22/2009 -9.95E-04 + 9.82E-03 1.59E-02 0.OOE+00 + 9.OOE-03 1.50E-02 12/22/2009 - 12/29/2009 -4.04E-03 + 1.11E-02 1.75E-02 -2.84E-03 + 1.17E-02 1.88E-02 I I I I I U I I I I I U I I I I I I NVS = Valid sample not obtained due to sampler failure. Page 2 of 6

TABLE A-4.1 GAMMA SPECTROMETRY RESULTS OF 1-131 ON CHARCOAL FILTERS Results in pCi/cubic meter, corrected for decay during collection period 1/6/2009 1/13/2009 1/20/2009 1/27/2009 1/13/2009 1/20/2009 1/27/2009 2/3/2009 U.UUIL+UU -2.58E-03 3.20E-04 9.97E-03 -1.29E-04 4-4- 4- -I 1.331L-u2 1.05E-02 6.77E-03 1.06E-02 1.06E-02 2.22L-U2 1.68E-02 1.10E-02 1.54E-02 1.74E-02 2.66L--04 2.64E-03 -6.19E-03 4.66E-03 6.OOE-03 +- +¢ 4-4- +- 1.06E-02 1.01 E-02 1.43E-02 1.OOE-02 1.09E-02 1.74E-02 1.59E-02 2.25E-02 1.55E-02 1.66E-02 2/3/2009 - 2/10/2009 -3.97E-04 + 8.30E-03 1.36E-02 3.93E-03 + 7.97E-03 1.21 E-02 2/10/2009 - 2/17/2009 -2.21 E-03 + 9.64E-03 1.54E-02 2.34E-03 + 1.05E-02 1.67E-02 2/17/2009 - 2/24/2009 4.65E-03 + 7.80E-03 1.1 5E-02 0.00E+00 + 1.50E-02 2.50E-02 2/24/2009 - 3/3/2009 0.OOE+00 + 1.05E-02 1.75E-02 4.18E-03 + 1.08E-02 1.69E-02 3/3/2009 - 3/10/2009 -2.23E-03 + 1.10E-02 1.76E-02 4.89E-05 + 8.84E-03 1.45E-02 3/10/2009 - 3/17/2009 2.33E-03 + 1.04E-02 1.67E-02 0.OOE+00 + 1.06E-02 1.76E-02 3/17/2009 - 3/24/2009 0.OOE+00 + 1.02E-02 1.70E-02 -2.85E-03 + 1.09E-02 1.74E-02 3/24/2009 - 3/31/2009 -1.91 E-04 + 1.01 E-02 1.65E-02 -1.45E-03 + 9.08E-03 1.46E-02 3/31/2009 - 4/7/2009 5.93E-04 + 1.04E-02 1.70E-02 -3.45E-03 + 1.15E-02 1.83E-02 4/7/2009 - 4/14/2009 -1.32E-03 + 7.72E-03 1.23E-02 -4.05E-03 + 1.06E-02 1.67E-02 4/14/2009 - 4/21/2009 4.32E-04 + 8.43E-03 1.38E-02 5.46E-03 + 1.14E-02 1.77E-02 4/21/2009 - 4/28/2009 4.37E-03 + 8.03E-03 1.21 E-02 1.77E-03 + 9.90E-03 1.59E-02 4/28/2009 - 5/5/2009 2.22E-04 + 9.34E-03 1.53E-02 1.48E-03 + 8.64E-03 1.38E-02 .5/5/2009 - 5/12/2009 -3.05E-03 + 9.98E-03 1.58E-02 -9.29E-04 + 9.93E-03 1.61E-02 5/12/2009 - 5/19/2009 -1.06E-03 + 9.76E-03 1.58E-02 -6.07E-05 + 9.03E-03 1.48E-02 5/19/2009 - 5/26/2009 -3.15E-04 + 9.01E-03 1.47E-02 -2.46E-03 + 1.04E-02 1.67E-02 5/26/2009 - 6/2/2009 -5.12E-05 + 1.OOE-02 1.65E-02 4.02E-03 + 9.87E-03 1.53E-02 6/2/2009 - 6/9/2009 -2.54E-04 + 9.35E-03 1.53E-02 4.14E-03 + 9.17E-03 1.41E-02 6/9/2009 - 6/16/2009 3.95E-03 + 8.OOE-03 1.21E-02 -4.12E-03 + 1.16E-02 1.83E-02 6/16/2009 - 6/23/2009 -3.34E-03 + 9.93E-03 1.56E-02 -2.51 E-03 + 1.07E-02 1.71 E-02 6/23/2009 - 6/30/2009 -1.78E-04 + 7.92E-03 1.30E-02 0.OOE+00 + 1.34E-02 2.23E-02 6/30/2009 - 7/7/2009 1.53E-03 + 9.06E-03 1.46E-02 -3.52E-05 + 1.02E-02 1.67E-02 7/7/2009 - 7/14/2009 2.50E-03 + 9.29E-03 1.47E-02 -3.87E-03 + 1.38E-02 2.21 E-02 7/14/2009 - 7/21/2009 0.OOE+00 + 1.19E-02 1.99E-02 1.49E-03 + 8.06E-03 1.29E-02 7/21/2009 - 7/28/2009 2.04E-03 + 1.05E-02 1.68E-02 2.63E-03 + 8.54E-03 1.33E-02 7/28/2009 - 8/4/2009 2.41 E-03 + 9.20E-03 1.46E-02 2.22E-03 + .1.1 7E-02 1.88E-02 8/4/2009 - 8/11/2009 6.69E-04 + 6.80E-03 1.10E-02 6.63E-04 + 9.24E-03 1.50E-02 8/11/2009 - 8/18/2009 7.22E-03 + 9.72E-03 1.44E-02 -4.66E-04 + 8.46E-03 1.38E-02 8/18/2009 - 8/25/2009 4.20E-04 + 9.64E-03 1.58E-02 8.45E-04 + 8.54E-03 1.38E-02 8/25/2009 - 9/1/2009 -3.88E-03 + 1.07E-02 1.69E-02 -1.80E-04 + 1.03E-02 1.69E-02 9/1/2009 - 9/8/2009 -3.21E-03 + 1.12E-02 1.78E-02 -4.32E-04 + 9.69E-03 1.58E-02 9/8/2009 - 9/15/2009 -2.71E-03 + 1.07E-02 1.71E-02 -2.61E-03 + 1.07E-02 1.71E-02 9/15/2009 - 9/22/2009 0.OOE+00 + 1.1 7E-02 1.94E-02 -1.42E-05 + 1.02E-02 1.67E-02 9/22/2009 - 9/29/2009 -1.58E-04 + 8.97E-03 1.47E-02 5.72E-03 + 1.10E-02 1.70E-02 9/29/2009 - 10/6/2009 1.07E-04 + 1.03E-02 1.70E-02 -3.02E-03 + 1.16E-02 1.85E-02 10/6/2009 - 10/13/2009 -2.06E-04 + 9.77E-03 1.60E-02 -2.44E-03 + 1.15E-02 1.85E-02 10/13/2009 - 10/20/2009 1.58E-03 + 8.80E-03 1.41 E-02 0.OOE+00 + 1.33E-02 2.22E-02 10/20/2009 - 10/27/2009 4.27E-03 + 9.20E-03 1.41E-02 -1.42E-03 + 1.01E-02 1.62E-02 10/27/2009 - 11/3/2009 NVS -5.97E-04 + 1.10E-02 1.79E-02 11/3/2009 - 11/10/2009 1.04E-03 + 8.90E-03 1.44E-02 -2.53E-05 + 8.33E-03 1.37E-02 11/10/2009 - 11/17/2009 -2.84E-03 + 1.20E-02 1.92E-02. 3.41E-04 + 9.36E-03 1.53E-02 11/17/2009 - 11/24/2009 -6.99E-04 + 8.43E-03 1.37E-02 NVS 11/24/2009 - 12/1/2009 1.03E-03 + 9.72E-03 1.57E-02 2.24E-03 + 1.02E-02 1.63E-02 12/1/2009 - 12/8/2009 -4.71E-03 + 1.30E-02 2.05E-02 4.75E-03 + 1.17E-02 1.83E-02 12/8/2009 - 12/15/2009 NVS 4.83E-03 + 1.11E-02 1.71E-02 12/15/2009 - 12/22/2009 0.OOE+00 + 9.OOE-03 1.50E-02 -2.36E-03 + 1.08E-02 1.72E-02 12/22/2009 - 12/29/2009 -4.04E-03 + 1.11E-02 1.75E-02 4.28E-03 + 1.24E-02 1.96E-02 NVS = Valid sample not obtained due to sampler failure. Page 3 of 6

TABLE A-4.1 GAMMA SPECTROMETRY RESULTS OF 1-131 ON CHARCOAL FILTERS Results in pCi/cubic meter, corrected for decay during collection period 12/30/2008 1/6/2009 1/13/2009 1/20/2009 1/27/2009 1/6/2009 1/13/2009 1/20/2009 1/27/2009 2/3/2009 0.OOE+00 -2.58E-03 3.20E-04 9.97E-03 -1.29E-04 + -t -+ 1.33E-02 1.05E-02 6.77E-03 1.06E-02 1.06E-02 2.22E-02 1.68E-02 1.10E-02 1.54E-02 1.74E-02 2.661--04 2.64E-03 -6.19E-03 4.66E-03 6.OOE-03 -I -I 1.06E-02 1.01 E-02 1.43E-02 1.OOE-02 1.09E-02 1.74E-02 1.59E-02 2.25E-02 1.55E-02 1.66E-02 2/3/2009 - 2/10/2009 -3.97E-04 + 8.30E-03 1.36E-02 3.93E-03 + 7.97E-03 1.21 E-02 2/10/2009 - 2/17/2009 -2.21 E-03 + 9.64E-03 1.54E-02 2.34E-03 + 1.05E-02 1.67E-02 2/17/2009 - 2/24/2009 4.65E-03 + 7.80E-03 1.1 5E-02 O.OOE+00 + 1.50E-02 2.50E-02 2/24/2009 - 3/3/2009 O.OOE+00 + 1.05E-02 1.75E-02 4.18E-03 + 1.08E-02 1.69E-02 3/3/2009 - 3/10/2009 -2.23E-03 + 1.10E-02 1.76E-02 4.89E-05 + 8.84E-03 1.45E-02 3/10/2009 - 3/17/2009 2.33E-03 + 1.04E-02 1.67E-02 O.OOE+00 + 1.06E-02 1.76E-02 3/17/2009 - 3/24/2009 O.OOE+00 + 1.02E-02 1.70E-02 -2.85E-03 + 1.09E-02 1.74E-02 3/24/2009 - 3/31/2009 -1.91 E-04 + 1.01 E-02 1.65E-02 -1.45E-03 + 9.08E-03 1.46E-02 3/31/2009 - 4/7/2009 5.93E-04 + 1.04E-02 1.70E-02 -3.45E-03 + 1.15E-02 1.83E-02 4/7/2009 - 4/14/2009 -1.32E-03 + 7.72E-03 1.23E-02 -4.05E-03 + 1.06E-02 1.67E-02 4/14/2009 - 4/21/2009 4.32E-04 + 8.43E-03 1.38E-02 5.46E-03 + 1.14E-02 1.77E-02 4/21/2009 - 4/28/2009 4.37E-03 +'i 8.03E-03 1.21 E-02 1.77E-03 + 9.90E-03 1.59E-02 4/28/2009 - 5/5/2009 2.22E-04 +, 9.34E-03 1.53E-02 1.48E-03 + 8.64E-03 1.38E-02 5/5/2009 - 5/12/2009 -3.05E-03 +,i 9.98E-03 1.58E-02 -9.29E-04 + 9.93E-03 1.61 E-02 5/12/2009 - 5/19/2009 -1.06E-03 + 9.76E-03 1.58E-02 -6.07E-05 + 9.03E-03 1.48E-02 5/19/2009 - 5/26/2009 -3.15E-04 + 9.01E-03 1.47E-02 -2.46E-03 + 1.04E-02 1.67E-02 5/26/2009 - 6/2/2009 -5.12E-05 + 1.OOE-02 1.65E-02 4.02E-03 + 9.87E-03 1.53E-02 6/2/2009 - 6/9/2009 -2.54E-04 + 9.35E-03 1.53E-02 4.14E-03 + 9.17E-03 1.41E-02 6/9/2009 - 6/16/2009 3.95E-03 + 8.OOE-03 1.21E-02 -4.12E-03 + 1.16E-02 1.83E-02 6/16/2009 - 6/23/2009 -3.34E-03 + 9.93E-03 1.56E-02 -2.51 E-03 + 1.07E-02 1.71 E-02 6/23/2009 - 6/30/2009 -1.78E-04 + 7.92E-03 1.30E-02 O.OOE+00 + 1.34E-02 2.23E-02 6/30/2009 - 7/7/2009 1.53E-03 + 9.06E-03 1.46E-02 -3.52E-05 + 1.02E-02 1.67E-02 7/7/2009 - 7/14/2009 2.50E-03 + 9.29E-03 1.47E-02 -3.87E-03 + 1.38E-02 2.21 E-02 7/14/2009 - 7/21/2009 O.OOE+00 + 1.19E-02 1.99E-02 1.49E-03 + 8.06E-03 1.29E-02 7/21/2009 - 7/28/2009 2.04E-03 + 1.05E-02 1.68E-02 2.63E-03 + 8.54E-03 1.33E-02 7/28/2009 - 8/4/2009 2.41 E-03 + 9.20E-03 1.46E-02 2.22E-03 + 1.1 7E-02 1.88E-02 8/4/2009 - 8/11/2009 6.69E-04 + 6.80E-03 1.10E-02 6.63E-04 + 9.24E-03 1.50E-02 8/11/2009 - 8/18/2009 7.22E-03 + 9.72E-03 1.44E-02 -4.66E-04 + 8.46E-03 1.38E-02 8/18/2009 - 8/25/2009 4.20E-04 + 9.64E-03 1.58E-02 8.45E-04 + 8.54E-03 1.38E-02 8/25/2009 - 9/1/2009 -3.88E-03 + 1.07E-02 1.69E-02 -1.80E-04 + 1.03E-02 1.69E-02 9/1/2009 - 9/8/2009 -3.21E-03 + 1.12E-02 1.78E-02 -4.32E-04 + 9.69E-03 1.58E-02 9/8/2009 - 9/15/2009 -2.71E-03 + 1.07E-02 1.71E-02 -2.61E-03 + 1.07E-02 1.71E-02 9/15/2009 - 9/22/2009 O.OOE+00 + 1.17E-02 1.94E-02 -1.42E-05 + 1.02E-02 1.67E-02 9/22/2009 - 9/29/2009 -1.58E-04 + 8.97E-03 1.47E-02 5.72E-03 + 1.10E-02 1.70E-02 9/29/2009 - 10/6/2009 1.07E-04 + 1.03E-02 1.70E-02 -3.02E-03 + 1.16E-02 1.85E-02 10/6/2009 - 10/13/2009 -2.06E-04 + 9.77E-03 1.60E-02 -2.44E-03 + 1.15E-02 1.85E-02 10/13/2009 - 10/20/2009 1.58E-03 + 8.80E-03 1.41 E-02 O.OOE+00 + 1.33E-02 2.22E-02 10/20/2009 - 10/27/2009 4.27E-03 + 9.20E-03 1.41E-02 -1.42E-03 + 1.01E-02 1.62E-02 10/27/2009 - 11/3/2009 8.77E-04 + 1.25E-02 2.04E-02 -5.97E-04 + 1.10E-02 1.79E-02 11/3/2009 - 11/10/2009 1.04E-03 + 8.90E-03 1.44E-02 -2.53E-05 + 8.33E-03 1.37E-02 11/10/2009 - 11/17/2009 -2.84E-03 + 1.20E-02 1.92E-02 3.41E-04 + 9.36E-03 1.53F-02 11/17/2009 - 11/24/2009 -6.99E-04 + 8.43E-03 1.37E-02 4.23E-05 + 7.36E-03 1.21E-02 11/24/2009 - 12/1/2009 1.03E-03 + 9.72E-03 1.57E-02 2.24E-03 + 1.02E-02 1.63E-02 12/1/2009 - 12/8/2009 -4.71E-03 + 1.30E-02 2.05E-02 5.87E-03 + 1.45E-02 2.27E-02 12/8/2009 - 12/15/2009 -2.86E-03 + 1.07E-02 1.71E-02 4.14E-03 + 9.54E-03 1.47E-02 12/15/2009 - 12/22/2009 -9.95E-04 + 9.82E-03 1.59E-02 -2.36E-03 + 1.08E-02 1.72E-02 12/22/2009 - 12/29/2009 -4.04E-03 + 1.11E-02 1.75E-02 4.28E-03 + 1.24E-02 1.96E-02 I I I I I I I I I I I I I I I I I I I NVS = Valid sample not obtained due to sampler failure. Page 4 of 6

TABLE A-4.1 GAMMA SPECTROMETRY RESULTS OF 1-131 ON CHARCOAL FILTERS Results in pCi/cubic meter, corrected for decay during collection period Station 7.............Station 48 Collection Period RQ Activity Error MDA RQ Activity Error MDA 12/30/2008-1/6/2009 -9.96E-04 + 1.14E-02 1.86E-02 2.66E-04 + 1.06E-02 1.74E-02 1/6/2009-1/13/2009 O.OOE+O0 + 1.12E-02 1.86E-02 2.64E-03 + 1.01E-02 1.59E-02 1/13/2009-1/20/2009 1.12E-03 + 9.26E-03 1.50E-02. -6.19E-03 + 1.43E-02 2.25E-02 1/20/2009-1/27/2009 -1.35E-03 + 1.05E-02 1.70E-02 4.66E-03 + 1.00E-02 1.55E-02 1/27/2009-2/3/2009 O.OOE+00 + 1.54E-02 2.56E-02 6.00E-03 + 1.09E-02 1.66E-02 2/3/2009 - 2/10/2009 O.OOE+O0 + 9.00E-03 1.50E-02 3.93E-03 + 7.97E-03 1.21 E-02 2/10/2009-2/17/2009 -7.17E-04 + 1.10E-02 1.79E-02 2.34E-03 + 1.05E-02 1.67E-02 2/17/2009-2/24/2009 -5.32E-04 + 8.92E-03 1.45E-02 O.OOE+00 + 1.50E-02 2.50E-02 2/24/2009 - 3/3/2009 2.69E-04 + 9.81E-03 1.61E-02 4.18E-03 + 1.08E-02 1.69E-02 3/3/2009-3/10/2009 1.34E-03 + 9.47E-03 1.53E-02 4.89E-05 + 8.84E-03 1.45E-02 3/10/2009 - 3/17/2009 1.02E-03 + 8.94E-03 1.45E-02 O.OOE+00 + 1.06E-02 1.76E-02 3/17/2009-3/24/2009 -3.58E-03 + 1.30E-02 2.08E-02 -2.85E-03 + 1.09E-02 1.74E-02 3/24/2009-3/31/2009 -7.46E-04 + 9.02E-03 1.46E-02 -1.45E-03 + 9.08E-03 1.46E-02 3/31/2009-4/7/2009 4.50E-04 + 1.06E-02 1.73E-02 -3.45E-03 + 1.15E-02 1.83E-02 4/7/2009-4/14/2009 1.52E-03 + 9.35E-03 1.50E-02 -4.05E-03 + 1.06E-02 1.67E-02 4/14/2009-4/21/2009 9.31E-04 + 9.95E-03 1.62E-02 5.46E-03 + 1.14E-02 1.77E-02 4/21/2009-4/28/2009 -1.29E-03 + 1.01 E-02 1.63E-02 1.77E-03 + 9.90E-03 1.59E-02 4/28/2009-5/5/2009 2.79E-03 + 9.41 E-03 1.49E-02 1.48E-03 + 8.64E-03 1.38E-02 5/5/2009-5/12/2009 2.13E-03 + 8.26E-03 1.30E-02 -9.29E-04 + 9.93E-03 1.61E-02 5/12/2009-5/19/2009 3.30E-03 + 9.68E-03 1.52E-02 -6.07E-05 + 9.03E-03 1.48E-02 5/19/2009-5/26/2009 2.06E-03 + 9.70E-03 1.55E-02 -2.46E-03 + 1.04E-02 1.67E-02 5/26/2009-6/2/2009 -1.80E-03 + 1.09E-02 1.76E-02 4.02E-03 + 9.87E-03 1.53E-02 6/2/2009-6/9/2009 -2.13E-04 + 9.83E-03 1.61E-02 4.14E-03 + 9.17E-03 1.41E-02 6/9/2009-6/16/2009 -2.82E-03 + 1.10E-02 1.76E-02 -4.12E-03 + 1.16E-02 1.83E-02 6/16/2009 - 6/23/2009 O.OOE+00 + 9.68E-03 1.61E-02 -2.51E-03 + 1.07E-02 1.71E-02 6/23/2009-6/30/2009 O.OOE+00 + 7.98E-03 1.33E-02 O.OOE+00 + 1.34E-02 2.23E-02 6/30/2009-7/7/2009 -4.72E-04 + 9.76E-03 1.59E-02 -3.52E-05 + 1.02E-02 1.67E-02 7/7/2009 - 7/14/2009 1.89E-04 + 9.47E-03 1.55E-02 -3.87E-03 + 1.38E-02 2.21 E-02 7/14/2009 - 7/21/2009 -1.04E-03 + 9.41 E-03 1.53E-02 1.49E-03 + 8.06E-03 1.29E-02 7/21/2009-7/28/2009 -4.15E-03 + 1.23E-02 1.96E-02 2.63E-03 + 8.54E-03 1.33E-02 7/28/2009-8/4/2009 3.25E-04 + 1.03E-02 1.69E-02 2.22E-03 + 1.1 7E-02 1.88E-02 8/4/2009-8/11/2009 7.62E-05 + 7.94E-03 1.30E-02 6.63E-04 + 9.24E-03 1.50E-02 8/11/2009-8/18/2009 5.91E-03 + 7.37E-03 1.06E-02 -4.66E-04 + 8.46E-03 1.38E-02 8/18/2009-8/25/2009 -1.67E-03 + 9.66E-03 1.55E-02 8.45E-04 + 8.54E-03 1.38E-02 8/25/2009-9/1/2009 6.37E-03 + 8.58E-03 1.24E-02 -1.80E-04 + 1.03E-02 1.69E-02 9/1/2009-9/8/2009 -2.91 E-04 + 9.32E-03 1.53E-02 -4.32E-04 + 9.69E-03 1.58E-02 9/8/2009 - 9/15/2009 -1.94E-03 + 8.52E-03 1.36E-02 -2.61 E-03 + 1.07E-02 1.71 E-02 9/15/2009 - 9/22/2009 -3.81 E-04 + 9.71 E-03 1.59E-02 -1.42E-05 + 1.02E-02 1.67E-02 9/22/2009-9/29/2009 -1.97E-04 + 1.03E-02 1.70E-02 5.72E-03 + 1.10E-02 1.70E-02 9/29/2009-10/6/2009 O.OOE+00 + 1.39E-02 2.32E-02 -3.02E-03 + 1.16E-02 1.85E-02 10/6/2009-10/13/2009 5.73E-03 + 1.09E-02 1.69E-02 -2.44E-03 + 1.15E-02 1.85E-02 10/13/2009-10/20/2009 2.32E-03 + 1.05E-02 1.68E-02 O.OOE+00 + 1.33E-02 2.22E-02 10/20/2009-10/27/2009 -2.11E-03 + 1.02E-02 1.63E-02 -1.42E-03 + 1.01E-02 1.62E-02 10/27/2009-11/3/2009 O.OOE+00 + 1.30E-02 2.17E-02 -5.97E-04 + 1.10E-02 1.79E-02 11/3/2009 - 11/10/2009 -7.93E-05 + 9.37E-03 1.54E-02 -2.53E-05 + 8.33E-03 1.37E-02 11/10/2009-11/17/2009 5.30E-04 + 1.01E-02 1.64E-02 3.41E-04 + 9.36E-03 1.53E-02 11/17/2009-11/24/2009 1.20E-03 + 7.97E-03 1.28E-02 4.23E-05 + 7.36E-03 1.21E-02 11/24/2009-12/1/2009 O.OOE+00 + 1.48E-02 2.47E-02 2.24E-03 + 1.02E-02 1.63E-02 12/1/2009 - 12/8/2009 O.OOE+00 + 1.30E-02 2.17E-02 4.75E-03 + 1.1 7E-02 1.83E-02 12/8/2009 - 12/15/2009 -1.67E-03 + 1.15E-02 1.86E-02 4.14E-03 + 9.54E-03 1.47E-02 12/15/2009 - 12/22/2009 -9.95E-04 + 9.82E-03 1.59E702 -2.36E-03 + 1.08E-02 1.72E-02 12/22/2009 - 12/29/2009 -2.84E-03 + 1.1 7E-02 1.88E-02 4.28E-03 + 1.24E-02 1.96E-02 NVS = Valid sample not obtained due to sampler failure. Page 5 of 6

'TABLE A-4.1 GAMMA SPECTROMETRY RESULTS OF 1-131 ON CHARCOAL FILTERS Results in pCi/cubic meter, corrected for decay during collection period Station 8 Station 57 Collection Period RQ9 Acqtivlty.. Error MDA RO Activity Error MDA 12/30/2008-1/6/2009 -9.96E-04 + 1.14E-02 1.86E-02 2.66E-04 + 1.06E-02 1.74E-02 1/6/2009 - 1/13/2009 0.OOE+00 + 1.12E-02 1.86E-02 2.64E-03 + 1.01E-02 1.59E-02 1/13/2009-1/20/2009 1.12E-03 + 9.26E-03 1.50E-02 -6.19E-03 + 1.43E-02 2.25E-02 1/20/2009-1/27/2009 -1.35E-03 + 1.05E-02 1.70E-02 4.66E-03 + 1.OOE-02 1.55E-02 1/27/2009 - 2/3/2009 0.OOE+00 + 1.54E-02 2.56E-02 6.OOE-03 + 1.09E-02 1.66E-02 2/3/2009 - 2/10/2009 0.OOE+00 + 9.OOE-03 1.50E-02 3.93E-03 + 7.97E-03 1.21E-02 2/10/2009-2/17/2009 -7.17E-04 + 1.10E-02 1.79E-02 2.34E-03 + 1.05E-02 1.67E-02 2/17/2009-2/24/2009 -5.32E-04 + 8.92E-03 1.45E-02 0.OOE+00 + 1.50E-02 2.50E-02 2/24/2009 - 3/3/2009 2.69E-04 + 9.81 E-03 1.61 E-02 8.95E-03 + 2.32E-02 3.63E-02 3/3/2009-3/10/2009 1.34E-03 + 9.47E-03 1.53E-02 4.89E-05 + 8.84E-03 1.45E-02 3/10/2009 - 3/17/2009 1.02E-03 + 8.94E-03 1.45E-02 0.OOE+00 + 1.06E-02 1.76E-02 3/17/2009 - 3/24/2009 -3.58E-03 + 1.30E-02 2.08E-02 -2.85E-03 + 1.09E-02 1.74E-02 3/24/2009 - 3/31/2009 -7.46E-04 + 9.02E-03 1.46E-02 -1.45E-03 + 9.08E-03 1.46E-02 3/31/2009 - 4/7/2009 4.50E-04 + 1.06E-02 1.73E-02 -3.45E-03 + 1.15E-02 1.83E-02 4/7/2009 - 4/14/2009 1.52E-03 + 9.35E-03 1.50E-02 -4.05E-03 + 1.06E-02 1.67E-02 4/14/2009 - 4/21/2009 9.31E-04 + 9.95E-03 1.62E-02 5.46E-03 + 1.14E-02 1.77E-02 4/21/2009 - 4/28/2009 -1.29E-03 + 1.01E-02 1.63E-02 1.77E-03 + 9.90E-03 1.59E-02 4/28/2009 - 5/5/2009 2.79E-03 + 9.41 E-03 1.49E-02 1.48E-03 + 8.64E-03 1.38E-02 5/5/2009 - 5/12/2009 2.13E-03 + 8.26E-03 1.30E-02 -9.29E-04 + 9.93E-03 1.61E-02 5/12/2009 - 5/19/2009 3.30E-03 + 9.68E-03 1.52E-02 -6.07E-05 + 9.03E-03 1.48E-02 5/19/2009 - 5/26/2009 2.06E-03 + 9.70E-03 1.55E-02 -2.46E-03 + 1.04E-02 1.67E-02 5/26/2009 - 6/2/2009 -1.80E-03 + 1.09E-02 1.76E-02 4.02E-03 + 9.87E-03 1.53E-02 6/2/2009 - 6/9/2009 -2.13E-04 + 9.83E-03 1.61E-02 4.14E-03 + 9.17E-03 1.41E-02 6/9/2009 - 6/16/2009 -2.82E-03 + 1.10E-02 1.76E-02 -4.12E-03 + 1.16E-02 1.83E-02 6/16/2009 - 6/23/2009 0.OOE+00 + 9.68E-03 1.61 E-02 -2.51 E-03 + 1.07E-02 1.71 E-02 6/23/2009 - 6/30/2009 0.OOE+00 + 7.98E-03 1.33E-02 0.OOE+00 + 1.34E-02 2.23E-02 6/30/2009 - 7/7/2009 -4.72E-04 + 9.76E-03 1.59E-02 -3.52E-05 + 1.02E-02 1.67E-02 7/7/2009 - 7/14/2009 1.89E-04 + 9.47E-03 1.55E-02 -3.87E-03 + 1.38E-02 2.21 E-02 7/14/2009 - 7/21/2009 -1.04E-03 + 9.41E-03 1.53E-02 1.49E-03 + 8.06E-03 1.29E-02 7/21/2009 - 7/28/2009 -4.15E-03 + 1.23E-02 1.96E-02 2.63E-03 + 8.54E-03 1.33E-02 7/28/2009 - 8/4/2009 3.25E-04 + 1.03E-02 1.69E-02 2.22E-03 + 1.1 7E-02 1.88E-02 8/4/2009 - 8/11/2009 7.62E-05 + 7.94E-03 1.30E-02 6.63E-04 + 9.24E-03 1.50E-02 8/11/2009 - 8/18/2009 5.91E-03 + 7.37E-03 1.06E-02 -4.66E-04 + 8.46E-03 1.38E-02 8/18/2009 - 8/25/2009 -1.67E-03 + 9.66E-03 1.55E-02 8.45E-04 + 8.54E-03 1.38E-02 8/25/2009 - 9/1/2009 6.37E-03 + 8.58E-03 1.24E-02 -1.80E-04 + 1.03E-02 1.69E-02 9/1/2009 - 9/8/2009 -2.91E-04 + 9.32E-03 1.53E-02 -4.32E-04 + 9.69E-03 1.58E-02 9/8/2009 - 9/15/2009 -1.94E-03 + 8.52E-03 1.36E-02 -2.61 E-03 + 1.07E-02 1.71 E-02 9/15/2009 - 9/22/2009 -3.81 E-04 + 9.71 E-03 1.59E-02 -1.42E-05 + 1.02E-02 1.67E-02 9/22/2009 - 9/29/2009 -1.97E-04 + 1.03E-02 1.70E-02 5.72E-03 + 1.10E-02 1.70E-02 9/29/2009 - 10/6/2009 0.OOE+00 + 1.39E-02 2.32E-02 -3.02E-03 + 1.16E-02 1.85E-02 10/6/2009 - 10/13/2009 5.73E-03 + 1.09E-02 1.69E-02 -2.44E-03 + 1.15E-02 1.85E-02 10/13/2009 - 10/20/2009 2.32E-03 + 1.05E-02 1.68E-02 0.OOE+00 + 1.33E-02 2.22E-02 10/20/2009 - 10/27/2009 -2.11E-03 + 1.02E-02 1.63E-02 -1.42E-03 + 1.01E-02 1.62E-02 10/27/2009 - 11/3/2009 O.OOE+00 + 1.30E-02 2.17E-02 -5.97E-04 + 1.10E-02 1.79E-02 11/3/2009 - 11/10/2009 -7.93E-05 + 9.37E-03 1.54E-02 -2.53E-05 + 8.33E-03 1.37E-02 11/10/2009 - 11/17/2009 5.30E-04 + 1.01E-02 1.64E-02 3.41E-04 + 9.36E-03 1.53E-02 11/17/2009 - 11/24/2009 1.20E-03 + 7.97E-03 1.28E-02 4.23E-05 + 7.36E-03 1.21 E-02 11/24/2009 - 12/1/2009 0.OOE+00 + 1.35E-02 2.24E-02 2.24E-03 + 1.02E-02 1.63E-02 12/1/2009 - 12/8/2009 0.OOE+00 + 1.37E-02 2.28E-02 4.75E-03 + 1.17E-02 1.83E-02 12/8/2009 - 12/15/2009 -1.67E-03 + 1.15E-02 1.86E-02 4.14E-03 + 9.54E-03 1.47E-02 12/15/2009 - 12/22/2009 0.OOE+00 + 9.OOE-03 1.50E-02 -2.36E-03 + 1.08E-02 1.72E-02 I I I I I I I I I I I I I I I I I I I NVS = Valid sample not obtained due to sampler failure. Page 6 of 6

TABLE A-4.2 1-131 ON CHARCOAL FILTERS -

SUMMARY

Results in pCi per cubic meter, corrected for decay during collection period Average Activity Activity Low Activity Average Number of Number of High MDA Samples Positive IDs Nuclide 1-131 1-131 Ind 2.98E-04 Cntl 1.67E-04 -6.19E-03 -4.15E-03 9.97E-03 6.37E-03 1.64E-02 1.65E-02 569 0 0 52 ,0 Ind = Indicator Stations Cntl = Control Station Page 1 of 1

Table A-5.1 GROSS BETA IN WATER Results in pCi per liter ST 26 River/Drinking Cntl ST 29 River/Drinking Ind Collection Period JRQ Activity Error MDA RO Activity Error MDA 01/05/09 - 02/02/09 1.22E+00 + 7.71 E-01 2.49E+00 1.31 E+00 - 7.99E-01 2.49E+00 02/02/09 - 03/02/09 -1.11E-01 + 8.68E-01 2.88E+00 2.57E-01 + 7.73E-01 2.72E+00 03/02/09 - 04/06/09 -1.97E-01 + 6.52E-01 2.33E+00 9.35E-01 + 7.06E-01 2.38E+00 04/06/09 - 05/06/09 7.23E-01 + 6.98E-01 2.31E+00 2.81E-01 + 6.62E-01 2.31E+00 05/04/09 - 06/01/09 -1.75E+00 + 8.53E-01 2.66E+00 -8.64E-01 + 8.06E-01 2.66E+00 06/02/09 - 07/01/09 2.94E-01 + 6.18E-01 2.20E+00 1.50E+00 + 7.07E-01 2.19E+00 07/01/09 - 08/03/09 8.26E-01 + 7.43E-01 2.50E+00 3.82E-01 + 7.06E-01 2.49E+00 08/03/09 - 08/31/09 1.33E+00 + 7.03E-01 2.23E+00 3.24E-01 + 6.35E-01 2.22E+00 08/31/09 - 10/05/09 9.25E-01 + 6.94E-01 2.26E+00 1.41E+00 + 7.19E-01 2.26E+00 10/05/09 - 11/02/09 4.86E-01 + 6.54E-01 2.24E+00 1.20E+00 + 7.39E-01 2.24E+00 11/02/09 - 11/30/09 7.92E-01 + 7.74E-01 2.56E+00 -2.59E-01 + 7.27E-01 2.53E+00 11/30/09 - 01/04/10 1.26E+00 + 6.29E-01 1.96E+00 + 2.32E+00 + 7.08E-01 1.96E+00 ST 27 CW Discharge Collection Period IRQ Activity Error MDA 01/05/09 - 02/02/09 + 3.64E+00 + 1.OOE+00 2.67E+00 02/02/09 - 03/02/09 + 4.56E+00 + 1.03E+00 2.84E+00 03/02/09 - 04/06/09 + 5.07E+00 + 9.93E-01 2.40E+00 04/06/09 - 05/06/09 + 2.67E+00 + 8.71E-01 2.53E+00 05/04/09 - 06/01/09 1.51 E+00 + 8.87E-01 2.79E+00 06/02/09 - 07/01/09 9.37E-01 + 6.84E-01 2.22E+00 07/01/09 - 08/03/09 + 2.72E+00 + 9.16E-01 2.71E+00 08/03/09 - 08/31/09 1.58E+00 + 7.25E-01 2.25E+00 08/31/09 - 10/05/09 + 3.43E+00 + 9.17E-01 2.52E+00 10/05/09 - 11/02/09 + 5.28E+00 + 1.05E+00 2.58E+00 11/02/09 - 11/30/09 + 4.17E+00 + 1.06E+00 2.97E+00 11/30/09 - 01/04/10 + 8.66E+00 + 1.15E+00 2.30E+00 I I I I I I I I I I I I I I I I I I I TABLE A-5.2 ARAQ_._ RI=TA IN WATI=I: .*1 IrdMMARY r.1PtA Q m Reu lt Win p qi prMmlitAe Results in pCi per liter Average Activity Activity Location Activity Low High Number of Samples Number of Positive IDs ST 26 Control ST 29 Indicator ST 27 Discharge 4.83E-01 -1.75E+00 1.33E+00 7.32E-01 -8.64E-01 2.32E+00 3.69E+00 9.37E-01 8.66E+00 12 12 12 0 1 9 RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 1 of 1

TABLE A-6.1 TRITIUM IN WATER Results in pCi per liter, MDA for all samples is 300 pCi/I Location Description Collection Period RO Activity Error 26 River/Drinking Control 29 River/Drinking Indicator 27 Plant Discharge 01/05/09 04/06/09 07/01/09 10/05/09 01/05/09 04/06/09 07/01/09 10/05/09 01/05/09 04/06/09 07/01/09 10/05/09 03/02/09 06/01/09 08/31/09 11/30/09 03/02/09 06/01/09 08/31/09 11/30/09 03/02/09 06/01/09 08/31/09 11/30/09 04/06/09 07/01/09 10/05/09 01/04/10 04/06/09 07/01/09 10/05/09 01/04/10 04/06/09 07/01/09 10/05/09 01/04/10 6.61 E+01 1.27E+02 7.32E+01 1.16E+02 9.85E+01 1.62E+02 4.37E+01 1.18E+02 1.01 E+02 1.04E+02 1.02E+02 1.03E+02 5.97E+01 1.09E+02 -2.36E+01 1.88E+02 1.24E+01 3.72E+01 -5.86E+01 8.90E+01 2.37E+02 1.59E+02 -1.25E+02 1.61 E+02 +r + +r 9.34E+01 9.49E+01 9.56E+01 9.82E+01 9.72E+01 9.54E+01 9.41 E+01 9.80E+01 9.69E+01 9.47E+01 9.54E+01 9.74E+01 9.47E+01 9.56E+01 9.94E+01 9.78E+01 9.68E+01 9.59E+01 9.31 E+01 9.42E+01 1.OOE+02 9.81 E+01 9.18E+01 9.69E+01 31 Ground Water Well 1 32 Ground Water Well 2 52 Ground Water Well 3 TABLE A-6.2 TRITIUM IN WATER - Summary Results in pCi per liter Average Activity Number of Activity Activity Number of Positive Low High Samples IDs Location Description River/Drinking Control 9.55E+01 River/Drinking Indicator 1.05E+02 6.61 E+01 1.27E+02 4 4.37E+01 1.62E+02 4 1.01 E+02 1.04E+02 4 -1.25E+02 2.37E+02 1i 0 0 0 0, Discharge Indicator 1.03E+02 Ground Water Indicator 7.04E+01 2 Quarterly tritium values reported for ST-26, 27, and 29 are average of monthly analysis values. RQ= results Qualifier. If blank, result is less than detection limit. If "+", result is above the detection limit. Page 1 of 1

I I Table A-7.1 GAMMA SPECTROMETRY RESULTS OF WATER STATION 26 - River/Drinking Control Results in pCi/liter, corrected for decay during collection period Location 26 collected 2/2/2009 FNu-ciiI-e RO. Aciivity Error MDA K-40 -1.77E+01 + 3.66E+01 5.08E+01 CR-51 -7.15E-01 + 2.07E+01 3.40E+01 MN-54 1.40E+00 + 1.66E+00 2.50E+00 CO-58 2.98E-01 + 1.97E+00 3.20E+00 FE-59 -1.54E-01 + 5.38E+00 8.82E+00 CO-60 9.69E-01 + 1.66E+00 2.54E+00 ZN-65 -1.23E+00 + 4.31 E+00 6.92E+00 ZRNB-95 5.42E-02 + 1.86E+00 3.05E+00 1-131 1.28E+00 + 4.92E+00 7.96E+00 CS-134 -1.24E-01 + 1.47E+00 2.40E+00 CS-137 -8.27E-01 + 1.95E+00 3.1OE+00 BALA140 1.02E+00 + 4.63E+00 7.41 E+00 BI-214 + 9.21E+00 + 4.79E+00 8.OOE+00 RA-226 -2.37E+01 + 6.29E+01 7.33E+01 Location 26 collected I Nucride RO Activity Error K-40 -3.33E+00 + CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA140 BI-214 RA-226 9.43E+00 + 7.28E-01 + 2.05E+00 + -1.04E+00 + -3.44E-01 + O.OOE+00 + 5.22E-02 + 2.54E+00 + 5.52E-02 + 0.OOE+00 + -1.89E+00 + 2.18E+00 + -6.91 E+00 + 2.71 E+01 1.93E+01 1.69E+00 1.37E+00 5.65E+00 1.73E+00 6.76E+00 2.22E+00 6.1 OE+00 1.85E+00 1.87E+00 5.30E+00 4.38E+00 4.58E+01 4/6/2009 SMDA 5.13E+01 3.08E+01 2.68E+00 1.79E+00 9.1 OE+00 2.79E+00 1.13E+01 3.64E+00 9.78E+00 3.04E+00 3.12E+00 8.34E+00 7.96E+00 7.28E+01 Location 26 collected 3/2/2009 F1Nuclide R0 Activity Error MDA K-40 -3.57E+01 + 5.27E+01 4.93E+01 CR-51 1.66E+00 + 1.89E+01 3.09E+01 MN-54 -1.71E-01 + 1.58E+00 2.56E+00 CO-58 -1.04E-01 + 1.78E+00 2.90E+00 FE-59 -6.35E-01 + 6.08E+00 9.90E+00 CO-60 3.82E-01 + 1.51E+00 2.41E+00 ZN-65 -1.03E+00 + 3.85E+00 6.17E+00 ZRNB-95 -2.56E-02 + 1.79E+00 2.94E+00 1-131 0.OOE+00 + 5.67E+00 9.45E+00 CS-134 6.13E-01 + 1.51E+00 2.40E+00 CS-1 37 3.56E-01 + 1.72E+00 2.77E+00 BALA140 -3.11E-02 + 4.06E+00 6.66E+00 BI-214 1.23E+00 + 3.86E+00 7.29E+00 RA-226 -5.59E+00 + 4.30E+01 7.05E+01 Location 26 collected 5/6/2009 IiNuclide RO

Activity, Error MD-A K-40

-4.47E+01 + 8.03E+01 5.17E+01 CR-51 0.OOE+00 + 2.33E+01 3.88E+01 MN-54 1.25E+00 + 1.89E+00 2.95E+00 CO-58 3.96E-01 + 2.03E+00 3.29E+00 FE-59 -1.08E+00 + 6.12E+00 9.90E+00 CO-60 7.62E-01 + 1.88E+00 2.96E+00 ZN-65 -1.91 E+00 + 4.43E+00 7.03E+00 ZRNB-95 7.81 E-01 + 2.02E+00 3.22E+00 1-131 0.00E+00 + 6.27E+00 1.04E+01 CS-1 34 1.27E-01 + 1.73E+00 2.83E+00 CS-1 37 1.55E-01 + 1.82E+00 2.97E+00 BALA140 1.18E+00 + 4.32E+00 6.87E+00 BI-214 -1.62E+00 + 5.89E+00 8.41E+00 RA-226 2.77E+01 + 5.39E+01 9.42E+01 Location 26 collected 7/1/2009 FNuclide RO

Activity, Error MDA 3

I I I Location 26 collected 6/1/2009 [-Nuclide RQ Activity Error MDA ] K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 RA-226 -2.81 E+01 + 0.OOE+00 + 1.37E+00 + -1.10E+00 + 9.46E-02 + 1.02E+00 + -1.59E+00 + -1.05E-01 + -1.91 E-01 + 1.75E-01 + 8.89E-01 + -5.12E-01 + -3.10E+00 + -7.54E+00 + 5.37E+01 2.13E+01 1.90E+00 2.22E+00 4.38E+00 1.76E+00 4.67E+00 2.12E+00 6.12E+00 1.63E+00 2.03E+00 4.80E+00 7.61 E+00 5.71 E+01 5.40E+01 3.56E+01 2.96E+00 3.51 E+00 7.i9E+00 2.73E+00 7.48E+00 3.47E+00 1.OOE+01 2.66E+00 3.24E+00 7.82E+00 8.49E+00 9.26E+01 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA 40 BI-214 RA-226 -2.88E+01 + -8.70E-01 + 1.36E+00 + 2.42E-01 + 5.40E+00 + 1.19E+00 + -1.70E+00 + 6.47E-01 + 6.50E-01 + -9.81 E-01 + 0.OOE+00 + -1.44E+00 + 2.70E+00 + -1.86E+01 + 5.22E+01 2.33E+01 1.93E+00 1.87E+00 5.97E+00 1.90E+00 4.81 E+00 2.17E+00 5.1OE+00 1.95E+00 2.44E+00 5.74E+00 4.72E+00 6.76E+01 5.25E+01 3.83E+01 3.OOE+00 3.04E+00 8.95E+00 2.93E+00 7.70E+00 3.50E+00 8.33E+00 3.11E+00 4.07E+00 9.23E+00 8.46E+00 9.54E+01 I I I I I I I I RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit.. Page 1 of 9

Table A-7.1 GAMMA SPECTROMETRY RESULTS OF WATER STATION 26 - River/Drinking Control Results in pCi/liter, corrected for decay during collection period Location 26 collected 8/3/2009 fN-uclide RQ Activity Error MDA-] K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA 40 BI-214 RA-226 -3.08E+01 + 4.33E-01 + 1.15E-01 + -8.67E-01 + -1.08E+00 + 7.45E-01 + -1.11E-01 + 1.40E-01 + 2.18E+00 + -4.26E-01 + 8.27E-01 + 0.OOE+00 + -6.74E-01 + -3.23E+01 + 4.71 E+01 2.07E+01 1.70E+00 2.37E+00 6.33E+00 1.83E+00 3.35E+00 1.55E+00 6.15E+00 1.95E+00 1.70E+00 6.84E+00 4.65E+00 7.85E+01 4.95E+01 3.39E+01 2.78E+00 3.80E+00 1.02E+01 2.87E+00 5.48E+00 2.52E+00 9.92E+00 3.16E+00 2.68E+00 1.14E+01 7.79E+00 7.67E+01 Location 26 collected 8/31/2009 FN-cilide RQ Activity Error MDA K-40 -2.26E+01 + 4.05E+01 5.06E+01 CR-51 6.53E-01 + 1.95E+01 3.21 E+01 MN-54 3.94E-01 + 1.42E+00 2.26E+00 CO-58 -7.02E-01 + 2.OOE+00 3.19E+00 FE-59 -1.42E+00 + 5.83E+00 9.35E+00 CO-60 1.65E+00 + 1.79E+00 2.65E+00 ZN-65 9.57E-02 + 3.54E+00 5.80E+00 ZRNB-95 -1.26E+00 + 2.35E+00 3.72E+00 1-131 3.26E+00 + 5.04E+00 7.96E+00 CS-134 -2.39E-01 + 1.83E+00 2.99E+00 CS-1 37 1.02E+00 + 1.97E+00 3.11 E+00 BALA140 -2.21 E+00 + 4.76E+00 7.41 E+00 BI-214 -4.27E-01 + 4.97E+00 8.48E+00 RA-226 -4.19E+00 + 4.48E+01 7.44E+01 Location 26 collected 10/5/2009 Location 26 collected 11/2/2009 MDA ] Nuchlde RQ Activity Error MDA I Nuclide K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 RA-226 RO Activity -3.37E+01 + -2.37E+00 + -5.16E-01 + O.OOE+00 + -7.72E-01 + 1.90E+00 + -7.53E-01 + -7.07E-02 + 1.67E+00 + 9.55E-01 + 9.65E-01 + -1.53E+00 + 1.28E+00 + -2.88E+01 + Error 5.23E+01 2.05E+01 2.01 E+00 2.32E+00 5.30E+00 1.69E+00 4.03E+00 1.92E+00 6.22E+00 1.72E+00 2.OOE+00 5.47E+00 4.40E+00 7.34E+01 5.03E+01 3.34E+01 3.24E+00 3.87E+00 8.56E+00 2.40E+00 6.50E+00 3.15E+00 1.01 E+01 2.72E+00 3.17E+00 8.69E+00 8.06E+00 7.67E+01 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 RA-226 -2.37E+01 + -1.11E+01 + -8.60E-01 + -9.80E-01 + -5.56E-02 + -6.40E-01 + -2.37E+00 + -5.34E-01 + 2.89E+00 + -1.88E-02 + -2.30E-01 + -8.93E-01 + 4.58E+00 + -4.59E+00 + 4.08E+01 1.99E+01 1.84E+00 2.04E+00 5.1OE+00 1.75E+00 4.50E+00 1.77E+00 5.07E+00 1.87E+00 2:00E+00 4.62E+00 4.76E+00 4.65E+01 5.01 E+01 3.17E+01 2.91 E+00 3.23E+00 8.37E+00 2.76E+00 7.08E+00 2.83E+00 8.08E+00 3.07E+00 3.26E+00 7.44E+00 8.34E+00 7.64E+01 Location 26 collected 11/30/2009 FN--cii e RO Activity Error MDA ] Location 26 collected 1/4/2010 FNuci-fde Ro Activity Error MDA K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA 40 BI-214 RA-226 -4.09E+01 + 4.99E+00 + 3.27E-01 + 0.OOE+00 + 2.90E-01 + 9.04E-01 + -1.54E+00 + -1.22E+00 + -2.34E-01 + 2.92E-02 + 9.76E-01 + -1.66E-01 + + 9.88E+00 + -2.99E+00 + 7.04E+01 2.12E+01 1.29E+00 2.44E+00 5.71 E+00 1.98E+00 4.62E+00 2.28E400 6.81 E+00 1.69E+00 1.66E+00 3.81 E+00 4.78E+00 4.32E+01 5.29E+01 3.44E+01 2.05E+00 4.06E+00 9.34E+00 3.11E+00 7.38E+00 3.59E+00 1.12E+01 2.77E+00 2.59E+00 6.22E+00 7.93E+00 7.36E+01 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA 40 BI-214 RA-226 -1.80E+01 + 7.93E-01 + 0.OOE+00 + 7.01 E-02 + 1.46E+00 + 1.85E-02 + -3.18E-02 + -1.95E-01 + 0.OOE+00 + -6.23E-01 + -4.42E-01 + 1.90E+00 + -1.84E+00 + 3.72E+00 + 4.03E+01 2.44E+01 2.62E+00 2.08E+00 6.12E+00 1.89E+00 4.27E+00 2.35E+00 8.76E+00 2.26E+00 2.08E+00 5.42E+00 6.53E+00 4.93E+01 4.98E+01 3.90E+01 4.35E+00 3.38E+00 9.62E+00 3.11E+00 6.99E+00 3.80E+00 1.34E+01 3.65E+00 3.35E+00 7.99E+00 9.54E+00 9.OOE+01 RQ = Results Qualifier. If blank, result is less than detection limit. If "+". result is above detection limit. Page 2 of 9

Table A-7.1 GAMMA SPECTROMETRY RESULTS OF WATER STATION 29 - River/Drinking Indicator Results in pCi/liter, corrected for decay during collection period Location 29 collected 2/2/2009 -Nu-clice-R-Activity Error MDA K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA1 40 BI-214 RA-226 -4.67E+01 + 4.12E+00 + 2.15E-01 + -6.44E-01 + 0.OOE+00 + 2.18E-03 + -2.29E-02 + 1.54E-01 + 2.36E-01 + 0.OOE+00 + 1.64E-02 + 0.OOE+00 + + 9.68E+00 + 2.58E+00 + 7.60E+01 1.77E+01 1.68E+00 1.98E+00 4.81 E+00 1.86E+00 3.36E+00 2.54E+00 5.74E+00 2.37E+00 1.82E+00 8.94E+00 4.82E+00 3.85E+01 5.04E+01 2.87E+01 2.73E+00 3.16E+00 8.01 E+00 3.05E+00 5.51 E+00 4.16E+00 9.41 E+00 3.95E+00 2.99E+00 1.49E+01 8.02E+00 6.97E+01 Location 29 collected 3/2/2009 [Nuciide RQ Activity Error MDA ] K-40 -5.65E+01 + 1.40E+02 5.42E+01 CR-51 1.19E+01 + 2.41E+01 3.88E+01 MN-54 1.17E-01 + 2.18E+00 3.57E+00 CO-58 1.30E+00 + 1.98E+00 3.08E+00 FE-59 4.53E+00 + 6.55E+00 1.01 E+01 CO-60 3.75E-01 + 1.85E+00 2.98E+00 ZN-65 1.25E-01 + 3.04E+00 4.97E+00 ZRNB-95 1.33E-01 + 2.56E+00 4.19E+00 1-131 -1.77E-02 + 6.68E+00 1.10E+01 CS-134 -6.82E-01 + 2.16E+00 3.49E+00 CS-137 6.33E-01 + 1.93E+00 3.1OE+00 BALA140 -3.89E-01 + 4.80E+00 7.83E+00 BI-214 2.95E+00 + 5.OOE+00 8.87E+00 RA-226 3.01 E+01 + 5.39E+01 9.40E+01 Location 29 collected 4/6/2009 Nuclide Ro Activity Error MDA K-40 -3.36E+01 + 5.21E+01 5.03E+01 CR-51 1.17E+01 + 2.26E+01 3.61 E+01 MN-54 9.67E-01 + 1.62E+00 2.51 E+00 CO-58 2.85E-01 + 1.83E+00 2.96E+00 FE-59 -3.19E-02 + 5.06E+00 8.31E+00 CO-60 9.OOE-01 + 1.66E+00 2.55E+00 ZN-65 8.70E-01 + 3.92E+00 6.30E+00 ZRNB-95 1.30E+00 + 1.93E+00 2.97E+00 1-131 6.17E+00 + 5.01E+00 7.40E+00 CS-134 -9.99E-01 + 1.95E+00 3.11E+00 CS-1 37 2.58E-01 + 1.76E+00 2.86E+00 BALA140 0.OOE+00 + 9.22E-01 1.54E+00 BI-214 1.51 E+00 + 4.15E+00 7.68E+00 RA-226 1.33E+01 + 3.86E+01 6.92E+01 Location 29 collected 6/1/2009 f1Nuclide RQ Activity Error MDA 1 K-40 -4.04E+01 + 7.04E+01 5.18E+01 CR-51 -3.88E+00 + 2.44E+01 3.99E+01 MN-54 8.36E-01 + 2.OOE+00 3.19E+00 CO-58 -6.57E-02 + 2.OOE+00 3.28E+00 FE-59 -9.88E-01 + 4.52E+00 7.22E+00 CO-60 1.34E+00 + 1.77E+00 2.68E+00 ZN-65 1.04E-01 + 3.92E+00 6.42E+00 ZRNB-95 2.03E+00 + 2.04E+00 3.09E+00 1-131 -2.91 E+00 + 6.03E+00 9.69E+00 CS-134 1.40E-02 + 1.99E+00 3.26E+00 CS-1 37 1.59E-01 + 2.07E+00 3.38E+00 BALA140 2.15E-01 + 4.80E+00 7.86E+00 81-214 1.43E+00 + 4.74E+00 8.59E+00 RA-226 -1.63E+02 + 5.04E+03 8.92E+01 Location 29 collected 5/6/2009 [ Nuclide RO Activity Error MDA K-40 -3.47E+01 + 5.19E+01 4.95E+01 CR-51 -3.50E+00 + 1.91E+01 3.1OE+01 MN-54 5.61E-01 + 1.36E+00 2.12E+00 CO-58 4.14E-01 + 1.87E+00 3.02E+00 FE-59 -1.47E+00 + 5.56E+00 8.88E+00 CO-60 3.82E-01 + 1.64E+00 2.62E+00 ZN-65 -9.66E-01 + 3.82E+00 6.12E+00 ZRNB-95 3.91 E-01 + 2.04E+00 3.30E+00 1-131 2.47E+00 + 4.92E+00 7.83E+00 CS-134 -8.49E-01 + 1.89E+00 3.03E+00 CS-137 -6.11E-01 + 1.74E+00 2.78E+00 BALA140 4.93E-02 + 3.60E+00 5.90E+00 BI-214 4.33E+00 + 4.48E+00 7.93E+00 RA-226 1.1 3E+01 + 3.70E+01 6.70E+01 I I I I I I I I I I I I I I U I I I I Location 29 collected Nuclide K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA140 BI-214 RA-226 RO Activity -3.30E+01 + 0.OOE+00 + 2.90E-01 + 8.34E-01 + 1.20E+00 + 1.26E+00 + 0.OOE+00 + 1.59E-01 + 2.26E+00 + -6.04E-01 + -5.92E-01 + -4.55E-01 + -1.08E+00 + -7.13E+00 + Error 5.24E+01 2.17E+01 1.98E+00 1.89E+00 4.89E+00 1.77E+00 7.02E+00 2.70E+00 6.41 E+00 1.96E+00 1.92E+00 5.19E+00 5.31 E+00 4.90E+01 7/1/2009 MDA"- 5.09E+01 3.61 E+01 3.21 E+00 2.97E+00 7.78E+00 2.68E+00 1.17E+01 4.43E+00 1.03E+01 3.17E+00 3.08E+00 8.44E+00 8.16E+00 7.68E+01 RO = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 3 of 9

Table A-7.1 GAMMA SPECTROMETRY RESULTS OF WATER STATION 29 - River/Drinking Indicator Results in pCi/liter, corrected for decay during collection period Location 29 collected fNi-lidei---- RActivity Error K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA140 BI-214 RA-226 -3.06E+01 + -1.66E+01 + -1.10E+00 + 1.88E+00 + -6.94E-02 + 9.13E-01 + 1.96E-02 + 1.23E+00 + 4.91 E-01 + -8.24E-01 + -1.50E-01 + -5.57E-01 + -3.92E+00 + -9.52E+00 + 5.80E+01 2.75E+01 2.06E+00 2.00E+00 5.82E+00 2.07E+00 4.33E+00 2.09E+00 8.20E+00 1.97E+00 2.15E+00 4.62E+00 9.09E+00 6.18E+01 8/3/2009 M 13A-- 5.43E+01 4.42E+01 3.27E+00 3.03E+00 9.56E+00 3.28E+00 7.12E+00 3.28E+00 1.34E+01 3.17E+00 3.52E+00 7.48E+00 8.71E+00 9.70E+01 Location 29 collected 8/31/2009 FN-clis*i* RQ Activity Error MDA K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA1 40 BI-214 RA-226 -2.63E+01 + -.1.09E+01 + -1.47E-01 + -3.11E-01 + 2.57E+00 + 2.25E+00 + 1.45E+00 + 2.71E-01 + 1.13E+00 + 2.14E-01 + -2.03E-01 + 0.OOE+00 + -2.51 E+00 + -2.20E+01 + 4.28E+01 2.19E+01 2.03E+00 1.96E+00 6.09E+00 1.83E+00 4.15E+00 1.86E+00 6.40E+00 1.78E+00 1.49E+00 3.47E+00 7.10E+00 6.30E+01 4.98E+01 3.51E+01 3.32E+00 3.17E+00 9.58E+00 2.60E+00 6.60E+00 3.01 E+00 1.04E+01 2.90E+00 2.42E+00 5.79E+00 8.40E+00 7.54E+01 Location 29 collected [--N-Ull-ce RQ Activity Error 10/5/2009 Location 29 collected 11/2/2009 MDA I [ Nuclide RQ Activity Error MDA ] K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-137 BALA 40 BI-214 RA-226 -4.33E+01 + -2.68E+00 + -8.40E-01 + -1.69E-01 + 3.58E+00 + 1.01 E+00 + 5.92E-01 + -1.02E+00 + 1.84E-01 + 4.66E-02 + -2.25E-01 + -2.31E+00 + -3.88E-01 + -2.42E+01 + 6.73E+01 2.38E+01 2.04E+00 1.66E+00 5.48E+00 1.84E+00 3.33E+00 2.12E+00 7.09E+00 1.90E+00 1.87E+00 5.74E+00 4.83E+00 6.85E+01 Location 29 collected SN-uclide RQ Activity Error 5.OOE+01 3.88E+01 3.24E+00 2.71 E+00 8.30E+00 2.84E+00 5.37E+00 3.34E+00 1.16E+01 3.13E+00 3.05E+00 8.97E+00 8.34E+00 7.80E+01 11/30/2009 MDA ] 5.05E+01 3.92E+01 2.55E+00 3.20E+00 8.98E+00 3.13E+00 8.79E+00 3.48E+00 1.00E+01 6.27E+00 4.53E+00 9.77E+00 9.07E+00 8.82E+01 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA 40 81-214 RA-226 -2.94E+01 + 8.70E+00 + 1.59E+00 + 8.97E-01 + 4.20E-01 + 1.34E+00 + 1.1 6E-01 + 1.1 0E+00 + 1.39E+00 + -8.84E-01 + -1.02E+00 + -2.60E-02 + 2.82E+00 + -1.36E+01 + 4.85E+01 1.72E+01 1.78E+00 1.81E+00 5.12E+00 1.99E+00 3.78E+00 2.17E+00 5.84E+00 1.41 E+00 2.09E+00 3.91E+00 4.80E+00 5.22E+01 5.11E+01 2.74E+01 2.70E+00 2.83E+00 8.34E+00 3.05E+00 6.20E+00 3.43E+00 9.49E+00 2.19E+00 3.32E+00 6.42E+00 8.53E+00 7.34E+01 Location 29 collected 1/4/2010 [FNuclide R0 Activity Error MDA K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA 40 BI-214 RA-226 -2.46E+01 + -6.65E+00 + 8.56E-01 + -6.40E-01 + 1.33E+00 + -4.98E-02 + 5.40E-01 + 1.34E+00 + 5.72E+00 + -1.34E-01 + 0.OOE+00 + 0.OOE+00 + + 9.42E+00 + 3.20E+01 + 5.04E+01 2.42E+01 1.64E+00 2.01 E+00 5.63E+00 1.91 E+00 5.39E+00 2.24E+00 6.49E+00 3.82E+00 2.72E+00 5.86E+00 5.29E+00 4.92E+01 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-137 BALA 40 BI-214 RA-226 -1.20E+01 + -3.51E-01 + -4.19E-01 + 8.74E-01 + -5.74E-01 + 3.10E-01 + 1.41 E+00 + 5.46E-01 + -2.82E+00 + 2.44E-02 + -5.13E-01 + 1.44E+00 + 4.21 E-01 + 1.08E+01 + 3.38E+01 2.08E+01 2.07E+00 1.94E+00 6.06E+00 2.OOE+00 4.40E+00 2.50E+00 9.34E+00 2.06E+00 2.00E+00 4.59E+00 5.13E+00 4.65E+01 4.95E+01 3.33E+01 3.34E+00 3.01E+00 9.69E+00 3.23E+00 6.97E+00 3.99E+00 1.38E+01 3.38E+00 3.21E+00 6.73E+00 9.58E+00 8.55E+01 RO = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 4 of 9

Table A-7.1 GAMMA SPECTROMETRY RESULTS OF WATER STATION 27 - Plant Discharge Water Indicator Results in pCi/liter, corrected for decay during collection period Location 27 collected 2/2/2009 SNuclide RQ Activity Error MDA K-40 -3.13E+01 + 5.41E+01 5.16E+01 CR-51 6.15E+00 + 2.51E+01 4.09E+01 MN-54 1.35E+00 + 1.95E+00 3.03E+00 CO-58 0.OOE+00 + 2.35E+00 3.92E+00 FE-59 4.65E+00 + 5.88E+00 8.91 E+00 CO-60 7.10E-01 + 1.95E+00 3.1OE+00 ZN-65 -9.99E-01 + 4.21 E+00 6.79E+00 ZRNB-95 7.55E-01 + 2.21E+00 3.55E+00 1-131 -1.90E+00 + 5.96E+00 9.66E+00 CS-1 34 -1.56E+00 + 2.20E+00 3.49E+00 CS-1 37 1.66E-02 + 1.97E+00 3.24E+00 BALA140 -9.77E-01 + 5.42E+00 8.75E+00 BI-214 -1.47E+00 + 5.83E+00 8.50E+00 RA-226 -2.OOE+01 + 7.15E+01 9.87E+01 Location 27 collected 4/6/2009 F-Nuclide RQ Activity Error MDA 1 Location 27 collected 3/2/2009 [Nuciide RO Activity Error MDA 1 K-40 -1.04E+01 + 3.20E+01 5.17E+01 CR-51 6.70E+00 + 1.89E+01 3.05E+01 MN-54 2.24E-04 + 1.93E+00 3.16E+00 CO-58 5.63E-01 + 1.72E+00 2.74E+00 FE-59 -1.79E+00 + 5.90E+00 9.40E+00 CO-60 -1.58E-03 + 1.28E+00 2.1OE+00 ZN-65 2.48E-01 + 3.37E+00 5.49E+00 ZRNB-95 7.36E-01 + 1.79E+00 2.82E+00 1-131 -7.01E-01 + 5.24E+00 8.55E+00 CS-134 1.01E-01 + 2.06E+00 3.38E+00 CS-137 -3.98E-01 + 1.71E+00 2.75E+00 BALA140 -1.48E-01 + 3.93E+00 6.43E+00 BI-214 -6.98E-01 + 4.72E+00 7.86E+00 RA-226 -1.14E+01 + 4.77E+01 7.04E+01 Location 27 collected 5/6/2009 FNuciidie RO Activity Error MDA K-40 -1.66E+01 + 3.38E+01 4.93E+01 CR-51 -6.97E+00 + 2.06E+01 3.32E+01 MN-54 -5.27E-01 + 1.75E+00 2.80E+00 CO-58 -3.84E-01 + 1.58E+00 2.54E+00 FE-59 1.45E+00 + 5.07E+00 8.04E+00 CO-60 -4.99E-01 + 1.81 E+00 2.89E+00 ZN-65 -1.18E+00 + 3.83E+00 6.11E+00 ZRNB-95 1.11 E+00 + 1.84E+00 2.85E+00 1-131 1.16E+00 + 5.44E+00 8.85E+00 CS-1 34 6.86E-01 + 1.80E+00 2.89E+00 CS-137 2.31E-01 + 1.82E+00 2.96E+00 BALA140 -1.29E+00 + 4.40E+00 6.97E+00 BI-214 1.67E+00 + 4.25E+00 7.81 E+00 RA-226 1.38E+01 + 3.84E+01 6.89E+01 Location 27 collected 7/1/2009 Nuclide RQ Activity Error MDA K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA140 BI-214 RA-226 -4.28E+01 + 1.36E+01 + 5.17E-02 + 2.14E-01 + -1.20E+00 + 2.79E-01 + 8.65E-02 + -2.84E-02 + -8.43E-01 + -6.66E-01 + 9.01 E-01 + -1.05E-01 + 2.70E-01 + -1.64E+01 + 6.43E+01 1.61 E+01 1.66E+00 1.96E+00 5.72E+00 1.59E+00 2.61 E+00 2.01 E+00 6.40E+00 1.97E+00 1.82E+00 4.89E+00 4.46E+00 5.48E+01 4.94E+01 2.49E+01 2.72E+00 3.20E+00 9.18E+00 2.56E+00 4.27E+00 3.31 E+00 1.04E+01 3.17E+00 2.88E+00 8.01 E+00 8.24E+00 7.32E+01 I I I I I I I I I I I I I I I I I I I Location 27 collected 6/1/2009 Nuclide R0 Activity Error MDA I K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 81-214 RA-226 4.52E+00 + -8.32E+00 + 2.91 E-01 + 1.59E+00 + -1.78E+00 + 1.32E+00 + -1.75E+00 + 9.63E-01 + -3.86E+00 + 3.44E-01 + 3.09E-01 + O.OOE+00 + 5.77E+00 + -8.99E+00 + 2.53E+01 2.20E+01 1.62E+00 2.16E+00 6.16E+00 1.87E+00 4.49E+00 2.01 E+00 6.40E+00 1.92E+00 1.86E+00 4.62E+00 4.89E+00 5.18E+01 5.09E+01 3.54E+01 2.63E+00 3.34E+00 9.83E+00 2.84E+00 7.14E+00 3.18E+00 1.02E+01 3.13E+00 3.02E+00 7.70E+00 8.45E+00 7.82E+01 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA140 BI-214 RA-226 -2.03E+01 + -3.93E+00 + -3.68E-01 + 0.OOE+00 + -1.45E+00 + 1.96E+00 + -2.31 E+00 + 6.04E-02 + 2.24E+00 + -8.38E-01 + -6.08E-01 + -6.81E-01 + -1.68E+00 + -2.11E+01 + 3.85E+01 2.19E+01 1.98E+00 2.38E+00 6.06E+00 1.67E+00 4.38E+00 1.74E+00 5.29E+00 2.04E+00 2.21 E+00 4.28E+00 6.08E+00 6.10E+01 5.07E+01 3.58E+01 3.21 E+00 3.96E+00 9.72E+00 2.36E+00 6.87E+00 2.85E+00 8.48E+00 3.27E+00 3.57E+00 6.89E+00 8.37E+00 7.43E+01 RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 5 of 9

Table A-7.1 GAMMA SPECTROMETRY RESULTS OF WATER STATION 27 - Plant Discharge Water Indicator Results in pCi/liter, corrected for decay during collection period Location 27 collected 8/3/2009 FN-uclide Ro Activity Error MDA Location 27 collected 8/31/2009 r Nuclide RQ Activity Error MDA K-40 CR-51 MN-54 C0-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 140 BI-214 RA-226 -2.88E+01 + 1.45E+01 + 5.08E-01 + 1.35E+00 + 4.33E+00 + 2.01 E+00 + -8.26E-01 + -5.54E-01 + 6.99E-01 + 5.45E-01 + 6.63E-02 + -1.36E+00 + -5.25E-01 + -5.13E+00 + 4.81 E+01 1.87E+01 1.89E+00 1.81 E+00 5.27E+00 1.84E+00 3.59E+00 2.06E+00 6.53E+00 1.95E+00 1.42E+00 4.84E+00 4.69E+00 4.70E+01 5.13E+01 2.93E+01 3.05E+00 2.75E+00 7.79E+00 2.66E+00 5.76E+00 3.31 E+00 1.07E+01 3.15E+00 2.33E+00 7.68E+00 8.01 E+00 7.65E+01 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA140 BI-214 RA-226 -1.99E+01 + 2.98E+00 + 0.OOE+00 + -1.01E+00 + 0.OOE+00 + 3.02E+00 + -8.33E-01 + 1.07E+00 + -1.50E+00 + 4.74E-01 + 7.07E-01 + -2.48E+00 + -4.13E+00 + -3.01 E+01 + 4.44E+01 2.18E+01 2.02E+00 2.15E+00 5.61 E+00 2.16E+00 4.58E+00 2.12E+00 6.27E+00 2.03E+00 1.99E+00 5.06E+00 1.09E+01 7.94E+01 5.55E+01 3.55E+01 3.36E+00 3.40E+00 9.35E+00 3.08E+00 7.41 E+00 3.34E+00 1.02E+01 3.29E+00 3.19E+00 7.87E+00 9.15E+00 8.OOE+01 Location 27 collected 10/5/2009 FNiiilide Ro Activity Error MD-A---* K-40 -2.57E+00 + 2.66E+01 5.12E+01 CR-51 1.21 E+01 + 1.87E+01 2.95E+01 MN-54 0.OOE+00 + 2.04E+00 3.39E+00 CO-58 0.OOE+00 + 2.33E+00 3.88E+00 FE-59 0.OOE+00 + 6.77E+00 1.13E+01 CO-60 1.33E+00 + 1.81 E+00 2.74E+00 ZN-65 4.26E-02 + 3.32E+00 5.44E+00 ZRNB-95 1.11E+00 + 1.97E+00 3.07E+00 1-131 2.51 E+00 + 7.23E+00 1.17E+01 CS-134 -6.OOE-01 + 2.15E+00 3.47E+00 CS-137 9.46E-01 + 1.80E+00 2.83E+00 BALA140 3.56E-02 + 5.52E+00 9.07E+00 BI-214 -3.05E+00 + 7.71E+00 8.28E+00 RA-226 -3.14E+01 + 8.1OE+01 7.98E+01 _ Location 27 collected 11/2/2009 FNu-clide RO Ac-tivity Er-rr MD-A--* K-40 -1.01E+01 + 3.28E+01 5.01 E+01 CR-51 -9.52E+00 + 2.26E+01 3.62E+01 MN-54 -1.43E+00 + 2.34E+00 3.67E+00 CO-58 -2.66E-01 + 2.20E+00 3.58E+00 FE-59 -1.82E+00 + 5.66E+00 8.94E+00 CO-60 -1.31 E+00 + 2.18E+00 3.37E+00 ZN-65 1.58E+00 + 4.51E+00 7.17E+00 ZRNB-95 1.87E+00 + 2.36E+00 3.63E+00 1-131 2.65E+00 + 6.18E+00 9.90E+00 CS-134 -2.50E-01 + 2.41E+00 3.95E+00 CS-1 37 9.26E-01 + 2.08E400 3.29E+00 BALA140 1.92E-01 + 4.21E+00 6.87E+00 BI-214 1.45E+00 + 5.05E+00 9.38E+00 RA-226 1.34E+01 + 5.02E+01 9.08E+01 Location 27 collected 1/4/2010 ! Nuclide RO Activity Error MDA ] Location 27 collected V-Nu*ilde RQ Activity Error K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 RA-226 -1.23E+01 + -7.80E+00 + 0.OOE+00 + 1.32E+00 + 2.64E+00 + -8.30E-01 + -1.06E+00 + -9.75E-03 + 4.11E+00 + 1.11E+00 + -1.77E-01 + -5.02E-02 + 7.13E+00 + 8.68E+00 + 3.64E+01 2.21 E+01 2.04E+00 1.67E+00 5.18E+00 2.1 0E+00 4.77E+00 2.07E+00 6.16E+00 1.85E+00 1.66E+00 4.97E+00 5.96E+00 5.02E+01 11/30/2009 MDA 5.16E+01 3.56E+01 3.40E+00 2.48E+00 7.92E+00 3.30E+00 7.69E+00 3.41 E+00 9.68E+00 2.90E+00 2.70E+00 8.15E+00 1.03E+01 9.1 OE+01 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 RA-226 -9.80E+00 +

  • 1.82E+01 +

1.13E+00 + -2.61E-01 + 3.67E+00 + O.OOE+00 + -2.01 E+00 + 1.33E-01 + -3.82E+00 + -1.93E+00 + -1.23E-01 + -1.75E-01 + 1.22E+00 + 1.18E+01 + 3.18E+01 2.33E+01 1.85E+00 1.95E+00 5.77E+00 2.30E+00 4.98E+00 2.35E+00 8.17E+00 2.69E+00 2.12E+00 4.94E+00 5.28E+00 4.86E+01 4.94E+01 3.55E+01 2.85E+00 3.13E+00 8.55E+00 3.84E+00 7.87E+00 3.81 E+00 1.19E+01 4.25E+00 3.47E+00 7.65E+00 9.74E+00 8.84E+01 RQ = Results Qualifier. It blank, result is less than detection limit. If "+". result is above detection limit. Page 6 of 9

I Table A-7.1 GAMMA SPECTROMETRY RESULTS OF WATER STATION 31 - Ground Water Well #1 Results in pCi/liter Location 31 collected 3/2/2009 -Nui-ci1de RQ Activity Error MDA K-40 -5.87E+01 + 2.59E+02 8.35E+01 CR-51 2.17E+00 + 1.84E+01 3.OOE+01 MN-54 -5.37E-01 + 3.OOE+00 4.85E+00 CO-58 8.67E-02 + 3.02E+00 4.94E+00 FE-59 3.86E+00 + 7.75E+00 1.20E+01 CO-60 1.16E+00 + 3.13E+00 4.92E+00 ZN-65 -5.52E+00 + 8.80E+00 1.38E+01 ZRNB-95 3.73E-01 + 3.33E+00 5.43E+00 1-131 -8.72E-01 + 3.28E+00 5.32E+00 CS-1 34 3.54E-01 + 2.83E+00 4.60E+00 CS-1 37 -2.33E-01 + 2.75E+00 4.49E+00 BALA140 -2.76E-01 + 3.46E+00 5.62E+00 BI-214 + 1.42E+02 + 1.38E+01 1.16E+01 RA-226 -1.09E+01 + 1.04E+02 1.58E+02 Location 31 collected 6/1/2009 [-Nuclide RQ Activity Error MDA K-40 -7.08E+01 + 6.30E+02 8.12E+01 CR-51 -4.12E+00 + 2.91E+01 4.76E+01 MN-54 7.78E-01 + 3.20E+00 5.15E+00 CO-58 -7.30E-01 + 3.37E+00 5.44E+00 FE-59 -3.90E+00 + 8.32E+00 1.30E+01 CO-60 1.20E+00 + 3.38E+00 5.34E+00 ZN-65 -8.61 E+00 + 1.15E+01 1.81 E+01 ZRNB-95 -7.94E-01 + 3.70E+00 5.99E+00 1-131 -1.39E-01 + 3.72E+00 6.11E+00 CS-1 34 1.30E+00 + 1.90E+00 2.87E+00 CS-1 37 -3.76E-01 + 2.89E+00 4.69E+00 BALA140 9.35E-02 + 4.27E+00 7.01 E+00 81-214 + 1.77E+02 + 1.44E+01 1.25E+01 RA-226 -1.30E+01 + 1.11E+02 1.63E+02 Location 31 collected [ Nuclide R( K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 RA-226 Activity -3.59E+01 + 5.37E+00 + 3.17E+00 + 1.66E-01 + -2.06E+00 + -2.56E-01 +/- -1.94E+00 + 2.91 E-01 + 1.70E+00 + -7.85E-01 + -1.05E+00 + -1.50E-01 + + 1.43E+02 + 6.34E+00 + Error 1.01 E+02 2.53E+01 3.1 OE+00 2.82E+00 7.88E+00 2.78E+00 7.13E+00 3.12E+00 2.89E+00 2.93E+00 3.73E+00 3.64E+00 1.49E+01 8.67E+01 8/31/2009 MDA -] 7.95E+01 4.11E+01 4.61 E+00 4.61 E+00 1.26E+01 4.52E+00 1.14E+01 5.1 OE+00 4.57E+00 4.72E+00 6.OOE+00 5.96E+00 1.32E+01 1.51 E+02 Nuclide RQ K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA 40 BI-214 + RA-226 Location 31 Activity -2.34E+01 + -2.48E+00 + -1.95E-03 + -5.50E-02 + -2.69E-01 + 1.83E-01 + 8.50E-01 + 6.41 E-01 + 4.43E-01 + -1.04E+00 + -5.41E-01 + -2.14E-01 + 9.23E+01 + -8.78E+00 + collected Error 7.11E+01 2.24E+01 2.78E+00 2.34E+00 6.34E+00 2.89E+00 2.33E+01 3.06E+00 3.21 E+00 2.97E+00 2.93E+00 3.99E+00 1.21 E+01 7.92E+01 11/30/2009 MDA 8.16E+01 3.65E+01 4.57E+00 3.83E+00 1.03E+01 4.71 E+00 3.82E+01 4.93E+00 5.23E+00 4.73E+00 4.72E+00 6.50E+00 1.25E+01 1.19E+02 I I I U I I RO = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 7 of 9

Table A-7.1 GAMMA SPECTROMETRY RESULTS OF WATER STATION 32 - Ground Water Well #2 Results in pCi/liter Location 32 collected 3/2/2009 [KNuclide RQ Activity Error MDA Location 32 collected 6/1/2009 7 Nuclide RQ Activity Error MDA ] K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA140 BI-214 RA-226 -3.48E+01 + 1.16E+01 + -1.64E-02 + 5.06E-02 + 7.32E+00 + 1.79E+00 + 0.OOE+00 + -1.77E+00 + 2.72E-01 + -1.05E+00 + -8.94E-01 + 5.64E-01 + + 4.03E+02 + 1.42E+00 + 1.01 E+02 3.1 OE+01 3.77E+00 2.86E+00 9.27E+00 3.38E+00 3.95E+01 3.86E+00 4.25E+00 6.20E+00 4.OOE+00 3.67E+00 2.18E+01 1.07E+02 8.13E+01 5.02E+01 6.20E+00 4.70E+00 1.40E+01 5.24E+00 6.58E+01 6.14E+00 6.97E+00 1.01E+01 6.48E+00 5.90E+00 1.27E+01 1.83E+02 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA 40 BI-214 RA-226 -1.53E+01 + -1.99E-01 + -3.69E+00 + -8.30E-01 + 5.33E-01 + -1.19E+00 + -1.78E+01 + -4.84E-01 + 5.46E-02 + 3.99E-01 + -5.96E+00 + 6.41 E+00 + + 7.61E+02 + -8.31E+00 + 7.10E+01 3.48E+01 5.34E+00 3.46E+00 1.01 E+01 4.45E+00 1.59E+01 4.31 E+00 4.63E+00 1.64E+01 5.91 E+00 5.40E+00 2.94E+01 1.45E+02 9.09E+01 5.73E+01 8.47E+00 5.57E+00 1.65E+01 7.16E+00 2.49E+01 7.03E+00 7.61 E+00 8.50E+00 9.26E+00 7.84E+00 1.71 E+01 2.21 E+02 Location 32 collected 8/31/2009 [7Nuciide Ff-Q-Activity Error MDA K-40 -3.30E+01 + 9.33E+01 7.99E+01 CR-51 -8.91 E+00 + 3.02E+01 4.90E+01 MN-54 1.93E+00 + 2.56E+00 3.85E+00 C0-58 2.38E-02 + 3.16E+00 5.19E+00 FE-59 -1.32E+00 + 7.67E+00 1.23E+01 CO-60 7.19E-01 + 2.89E+00 4.61E+00 ZN-65 -2.06E-01 + 8.23E+00 1.35E+01 ZRNB-95 -1.13E+00 + 3.40E+00 5.44E+00 1-131 6.83E-01 + 3.93E+00 6.40E+00 CS-134 -2.OOE-01 + 7.31E+00 1.20E+01 CS-1 37 1.13E+00 + 2.48E+00 3.87E+00 BALA140 -1.77E-01 + 4.21E+00 6.88E+00 BI-214 + 1.27E+02 + 1.43E+01 1.30E+01 RA-226 -6.45E+00 + 9.54E+01 1.53E+02 Location 32 collected 11/30/2009 FNu6iie RQ Activity Error MDA K-40 -2.79E+01 + 6.97E+01 7.57E+01 CR-51 -6.73E+00 + 2.59E+01 4.20E+01 MN-54 4.51 E-02 + 2.32E+00 3.81 E+00 CO-58 -8.53E-02 + 2.52E+00 4.12E+00 FE-59 -4.43E+00 + 9.24E+00 1.43E+01 CO-60 1.13E+00 + 3.06E+00 4.78E+00 ZN-65 -5.56E+00 + 1.09E+01 1.73E+01 ZRNB-95 -3.07E-01 + 2.83E+00 4.59E+00 1-131 -1.76E+00 + 3.85E+00 6.14E+00 CS-1 34 -6.58E-01 + 3.24E+00 5.24E+00 CS-137 -6.69E-01 + 3.11E+00 5.01E+00 BALA140 -1.82E+00 + 4.63E+00 7.22E+00 BI-214 + 1.70E+02 + 1.53E+01 1.20E+01 RA-226 4.03E+01 + 7.66E+01 1.31 E+02 RO = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 8 of 9

Table A-7.1 GAMMA SPECTROMETRY RESULTS OF WATER STATION 52 - Ground Water Well #3 Results in pCi/liter FNiuclide RQ K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA140 BI-214 RA-226 Location 52 collected Activity Error -4.80E+01 + 1.24E+02 -5.88E+00 + 2.49E+01 -1.21 E-02 + 2.70E+00 -1.37E+00 + 2.94E+00 3.04E+00 + 6.94E+00 1.02E+00 + 2.62E+00 -3.69E-01 + 5.98E+00 5.73E-01 + 2.79E+00 2.72E+00 + 2.90E+00 1.43E+00 + 2.48E+00 -8.46E-01 + 2.88E+00 -1.43E+00 + 4.33E+00 2.02E+00 + 6.69E+00 4.47E+01 + 7.72E+01 3/2/2009 MDA ] 7.22E+01 4.04E+01 4.43E+00 4.61 E+00 1.07E+01 4.07E+00 9.76E+00 4.50E+00 4.43E+00 3.87E+00 4.60E+00 6.82E+00 1.21 E+01 1.34E+02 Location 52 collected 6/1/2009 F-iidi-ii Ro Activity Error MDA ] K-40 -5.75E+01 + 1.83E+02 7.68E+01 CR-51 -6.64E+00 + 2.09E+01 3.36E+01 MN-54 1.31 E+00 + 1.91E+00 2.75E+00 CO-58 2.07E-02 + 2.01 E+00 3.29E+00 FE-59 4.36E+00 + 5.77E+00 8.09E+00 CO-60 2.57E+00 + 2.79E+00 3.94E+00 ZN-65 -2.60E+00 + 6.48E+00 1.01 E+01 ZRNB-95 0.OOE+00 + 3.11E+00 5.19E+00 1-131 1.08E+00 + 2.80E+00 4.45E+00 CS-1 34 -9.73E-02 + 1.77E+00 2.88E+00 CS-1 37 1.83E+00 + 2.73E+00 4.14E+00 BALAi40 -8.40E-01 + 3.85E+00 6.1OE+00 BI-214 2.54E+00 + 6.86E+00 1.23E+01 RA-226 -3.03E+01 + 1.06E+02 1.08E+02 Location 52 collected 11/30/2009 [-Nuclide RQ Activity Error MDA7] K-40 -3.34E+01 + 8.16E+01 7.65E+01 CR-51 2.47E+00 + 1.87E+01 3.04E+01 MN-54 -3.55E-01 + 2.40E+00 3.87E+00 CO-58 -3.61 E-01 + 2.40E+00 3.87E+00 FE-59 0.OOE+00 + 1.13E+01 1.88E+01 CO-60 8.02E-01 + 2.61 E+00 4.09E+00 ZN-65 -2.47E+00 + 6.40E+00 1.OOE+01 ZRNB-95 0.OOE+00 + 3.90E+00 6.50E+00 1-131 -3.52E-01 + 3.95E+00 6.46E+00 CS-134 -1.42E+00 + 2.87E+00 4.51 E+00 CS-1 37 2.OOE-01 + 2.43E+00 3.94E+00 BALA140 4.41E-02 + 3.36E+00 5.51E+00 BI-214 3.03E+00 + 7.04E+00 1.25E+01 RA-226 -4.06E+01 + 1.29E+02 1.08E+02 Location 52 collected 8/31/2009 7Nuclide RQ Activity Error MDA K-40 -3.64E+01 + 1.01E+02 7.92E+01 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-137 BALA 140 BI-214 RA-226 2.79E+01 + 3.84E-02 + 0.OOE+00 + -8.53E-02 + 1.25E+00 + 0.OOE+00 + 4.75E-01 + -5.11E-01 + -3.51E-02 + -8.92E-01 + -1.73E+00 + 4.10E-01 + 1.05E+01 + 1.73E+01 2.89E+00 2.71 E+00 7.58E+00 2.39E+00 9.36E+00 2.51 E+00 3.65E+00 2.95E+00 3.21 E+00 4.27E+00 6.48E+00 7.89E+01 2.45E+01 4.74E+00 4.51 E+00 1.24E+01 3.61 E+00 1.56E+01 4.05E+00 5.96E+00 4.85E+00 5.15E+00 6.64E+00 1.19E+01 1.38E+02 I I I I I I I I I I I I I I I I I I I RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 9 of 9

TABLE A-7.2 GAMMA SPECTROMETRY RESULTS OF WATER -

SUMMARY

Results in pCi per liter, corrected for decay during collection period RIVER/DRINKING Average Activity Activity Average Number of Number of Nuclide Activity Low High MDA Samples Positive IDs BALA140 Ind -1.69E-01 -2.31 E+00 1.44E+00 7.63E+00 12 0 BALA140 Cntl -3.81E-01 -2.21E+00 1.90E+00 7.96E+00 12 0 BI-214 Ind 2.05E+00 -3.92E+00 9.68E+00 8.49E+00 12 2 BI-214 Cntl 1.95E+00 -3.1OE+00 9.88E+00 8.23E+00 12 2 CO-58 Ind 3.88E-01 -6.44E-01 1.88E+00 3.03E+00 12 0 CO-58 CntI -5.80E-02 -1.10E+00 2.05E+00 3.27E+00 12 0 CO-60 Ind 8.36E-01 -4.98E-02 2.25E+00 2.89E+00 12 0 CO-60 Cntl 7.14E-01 -6.40E-01 1.90E+00 2.77E+00 12 0 CR-51 Ind -6.85E-01 -1.66E+01 1.19E+01 3.57E+01 12 0 CR-51 Cntl 2.38E-01 -1.11E+01 9.43E+00 3.44E+01 12 0 CS-134 Ind -3.90E-01 -9.99E-01 2.14E-01 3.42E+00 12 0 CS-134 Cntl -3.81 E-02 -9.81 E-01 9.55E-01 2.90E+00 12 0 CS-137 Ind -1.88E-01 -1.02E+00 6.33E-01 3.19E+00 12 0 CS-137 Cntl 3.08E-01 -8.27E-01 1.02E+00 3.12E+00 12 0 FE-59 Ind 8.75E-01 -1.47E+00 4.53E+00 8.73E+00 12 0 FE-59 CntI 8.43E-02 -1.42E+00 5.40E+00 9.11E+00 12 0 1-131 Ind 1.19E+00 -2.91E+00 6.17E+00 1.04E+01 12 0 1-131 CntI 1.17E+00 -2.34E-01 3.26E+00 9.72E+00 12 0 K-40 Ind -3.43E+01 -5.65E+01 -1.20E+01 5.10E+01 12 0 K-40 Cntl -2.73E+01 -4.47E+01 -3.33E+00 5.11E+01 12 0 MN-54 Ind 2.44E-01 -1.10E+00 1.59E+00 2.98E+00 12 0 MN-54 Cntl 4.50E-01 -8.60E-01 1.40E+00 2.85E+00 12 0 RA-226 Ind -1.16E+01 -1.63E+02 3.20E+01 8.03E+01 12 0 RA-226 Cntl -8.65E+00 -3.23E+01 2.77E+01 8.05E+01 12 0 ZN-65 Ind 3.54E-01 -9.66E-01 1.45E+00 6.84E+00 12 0 ZN-65 Cntl -1.01E+00 -2.37E+00 9.57E-02 7.15E+00 12 0 ZRNB-95 Ind 6.37E-01 -1.02E+00 2.03E+00 3.56E+00 12 0 ZRNB-95 Cntl -1.44E-01 -1.26E+00 7.81E-01 3.29E+00 12 0 Ind = Indicator Stations Ontl = Control Stations Page 1 of 2

TABLE A-7.2 GAMMA SPECTROMETRY RESULTS OF WATER -

SUMMARY

DISCHARGE Nuclide K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA1 40 131-214 RA-226 Nuclide K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA140 81-214 RA-226 Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Average Activity -1.67E+01 3.14E+00 8.42E-02 2.60E-01 7.25E-01 6.65E-01 -7.51 E-01 6.02E-01 6.26E-02 -2.15E-01 2.33E-01 -5.87E-01 4.97E-01 -8.08E+00 Activity Activity Average Number of Low High MDA Samples -4.28E+01 4.52E+00 5.11E+01 12 -9.52E+00 1.82E+01 3.35E+01 12 -1,43E+00 1.35E+00 3.11E+00 12 -1.01 E+00 1.59E+00 3.24E+00 12 -1.82E+00 4.65E+00 9.08E+00 12 -1.31 E+00 3.02E+00 2.90E+00 12 -2.31 E+00 1.58E+00 6.50E+00 12 -5.54E-01 1.87E+00 3.26E+00 12 -3.86E+00 4.11E+00 1.OOE+01 12 -1.93E+00 1.11E+00 3.36E+00 12 -6.08E-01 9.46E-01 3.02E+00 12 -2.48E+00 1.92E-01 7.67E+00 12 -4.13E+00 7.13E+00 8.68E+00 12 -3.14E+01 1.38E+01 8.09E+01 12 Number of Positive IDs 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Number of Positive IDs I i I I I I I U I U I I Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind GROUNDWATER Average Activity Activity Activity Low High -3.96E+01 -5.44E+01 -2.41 E+01 1.21 E+00 -6.56E+00 1.49E+01 2.22E-01 -1.53E+00 2.14E+00 -2.57E-01 -9.77E-01 7.92E-02 5.87E-01 -2.81 E+00 5.18E+00 8.64E-01 -2.15E-01 1.85E+00 -3.68E+00 -9.66E+00 2.83E-01 -1.78E-01 -8.54E-01 3.02E-01 2.76E-01 -1.05E+00 1.70E+00 -1.49E-01 -1.17E+00 1.05E+00 -6.92E-01 -2.63E+00 9.08E-01 3.90E-02 -1.28E+00 2.18E+00 1.69E+02 7.32E+01 3.14E+02 -1.25E+00 -2.06E+01 3.04E+01 Average MDA 7.99E+01 4.02E+01 4.77E+00 4.56E+00 1.29E+01 4.75E+00 2.07E+01 5.41 E+00 5.80E+00 7.27E+00 5.20E+00 6.50E+00 1.28E+01 1.47E+02 Number of Samples 12 12 12 12 12 12 12 12 12 12 12 12 12 12 I I I U I Ind = Indicator Stations Cnti = Control Stations Page 2 of 2

TABLE A-8.1 GAMMA SPECTROMETRY RESULTS OF SOIL Results in pCi/kilogram Location & Date Station 1 6/10/2009 FNu-cIid&e RQ Ac-tivity Error MD-A--] Location & Date Station 7 6/10/2009 FNu--cidcef RQ A*-ti~ity Error MD-A--] BE-7 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA 140 BI-214 RA-226 7.42E-01 + + 1.53E+04 + -4.08E+00 + 2.53E+01 + -3.67E+00 + -2.38E+01 + -1.58E+00 + -3.56E+01 + 3.43E+01 + -7.95E+00 + + 1.43E+02 + -4.93E+00 + + 5.74E+02 + 1.33E+03 + 2.16E+02 1.21 E+03 2.14E+02 3.OOE+01 2.78E+01 8.66E+01 3.95E+01 7.73E+01 2.45E+01 2.97E+01 4.48E+01 3.55E+01 9.52E+01 8.53E+02 3.55E+02 4.66E+02 3.51 E+02 4.47E+01 4.50E+01 1.38E+02 6.47E+01 1.21 E+02 3.26E+01 4.77E+01 5.47E+01 5.71 E+01 9.21 E+01 1.34E+03 BE-7 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 BI-214 RA-226 1.34E+02 + + 1.48E+04 + -7.85E+01 + 9.27E+00 + 5.53E-01 + 3.19E+01 + 1.13E+01 + 2.66E+01 + -1.33E+01 + 0.OOE+00 + 6.54E+00 + 9.06E+00 + + 4.35E+02 + 1.15E+03 + 1.94E+02 1.12E+03 2.15E+02 2.37E+01 2.47E+01 6.72E+01 2.90E+01 4.25E+01 3.07E+01 4.64E+01 2.61 E+01 2.35E+01 8.56E+01 8.06E+02 Location & Date Station 9a 6/10/2009 FNuc-lide RQ A1ivity Error MD-A---] Location & Date Station 21 FNu-clide RQ A-tiivfity Error 2.97E+02 4.64E+02 3.45E+02 3.71 E+01 4.05E+01 1.03E+02 4.55E+01 6.26E+01 4.85E+01 7.73E+01 4.18E+01 3.55E+01 9.67E+01 1.28E+03 6/10/2009 M D-A--7 3.20E+02 4.13E+02 3.07E+02 3.22E+01 3.16E+01 1.13E+02 4.61 E+01 1.05E+02 3.98E+01 1.44E+01 4.05E+01 4.08E+01 8.11E+01 1.19E+03 BE-7 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 BI-214 RA-226 2.04E+02 + + 1.38E+04 + 6.67E+01 + 1.51 E+01 + 7.45E-01 + -2.01E+01 + 5.28E+00 + -9.87E+00 + 5.43E+00 + -1.15E+01 + + 5.18E+01 + 0.OOE+00 + + 5.70E+02 + 1.18E+03 + 2.45E+02 1.21 E+03 2.02E+02 2.81 E+01 2.72E+01 8.69E+01 3.78E+01 2.22E+02 2.82E+01 3.03E+01 3.56E+01 8.28E+00 1.09E+02 8.97E+02 3.69E+02 5.OOE+02 3.23E+02 4.30E+01 4.45E+01 1.38E+02 6.12E+01 3.64E+02 4.52E+01 4.79E+01 4.91 E+01 1.38E+01 9.56E+01 1.43E+03 BE-7 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 BI-214 RA-226 1.85E+01 + + 1.31E+04+ -5.69E+01 + -1.24E-01 + -1.30E+00 + -1.88E+01 + 1.34E+01 + -2.43E+01 + 9.90E+00 + 3.51 E+00 + 9.25E+00 + -1.57E+00 + + 3.45E+02 + 6.58E+02 + 1.97E+02 1.03E+03 1.91 E+02 1.96E+01 1.94E+01 7.11E+01 2.96E+01 6.65E+01 2.52E+01 9.59E+00 2.56E+01 2.51 E+01 7.34E+01 7.31 E+02 Location & Date Station 23 6/10/2009 FNu-cIidle RQ Activity Error MDi-A-- BE-7 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA 40 BI-214 RA-226 1.87E+02 + + 1.43E+04 + -1.39E+01 + 1.96E+01 + -9.62E+00 + 1.33E+01 + -1.66E+00 + 1.05E+00 + 2.67E+00 + -4.18E+00 + 4.39E+01 + 0.OOE+00 + + 4.75E+02 + 7.65E+02 + 2.18E+02 1.09E+03 1.90E+02 2.25E+01 2.44E+01 7.55E+01 2.70E+01 6.37E+01 2.38E+01 2.29E+01 3.44E+01 3.93E+01 8.65E+01 7.67E+02 3.31 E+02 3.77E+02 3.11 E+02 3.26E+01 3.82E+01 1.22E+02 4.40E+01 1.04E+02 3.87E+01 3.69E+01 5.03E+01 6.55E+01 9.19E+01 1.24E+03 RO = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 1 of 1

TABLE A-8.2 GAMMA SPECTROMETRY RESULTS OF SOIL -

SUMMARY

Results in pCi/kilogram Average Activity Activity Low Nuclide BALA140 BALA140 BE-7 BE-7 BI-214 BI-214 CO-58 CO-58 CO-60 CO-60 CR-51 CR-51 CS-134 CS-134 CS-137 CS-137 FE-59 FE-59 K-40 K-40 MN-54 MN-54 RA-226 RA-226 ZN-65 ZN-65 ZRNB-95 ZRNB-95 Ind Cntl Ind Cntl Ind Cnti Ind Cnti Ind CntI Ind Cnti Ind Cntl Ind Cntl Ind CntI Ind Cnti Ind Cntl Ind CntI Ind CntI Ind Cnti 6.40E-01 0.OOE+00 8.49E+01 2.04E+02 4.57E+02 5.70E+02 -3.51 E+00 7.45E-01 5.35E+00 5.28E+00 -3.84E+01 6.67E+01 -2.16E+00 -1.1 5E+01 5.07E+01 5.18E+01 6.50E-01 -2.01 E+01 1.44E+04 1.38E+04 1.35E+01 1.51 E+01 9.76E+02 1.18E+03 -8.05E+00 -9.87E+00 8.40E+00 5.43E+00 -4.93E+00 0.00E+00 7.42E-01 2.04E+02 3.45E+02 5.70E+02 -9.62E+00 7.45E-01 -1.66E+00 5.28E+00 -7.85E+01 6.67E+01 -7.95E+00 -1.15E+01 6.54E+00 5.18E+01 -2.38E+01 -2.01 E+01 1.31 E+04 1.38E+04 -1.24E-01 1.51 E+01 6.58E+02 1.18E+03 -3.56E+01 -9.87E+00 -11.33E+01 5.43E+00 Activity Average High MDA 9.06E+00 4.98E+01 0.00E+00 1.38E+01 1.87E+02 3.26E+02 2.04E+02 3.69E+02 5.74E+02 9.04E+01 5.70E+02 9.56E+01 5.53E-01 3.88E+01 7.45E-01 4.45E+01 1.34E+01 5.01E+01 5.28E+00 6.12E+01 -4.08E+00 3.28E+02 6.67E+01 3.23E+02 3.51E+00 4.41E+01 -1.15E+01 4.79E+01 1.43E+02 4.68E+01 5.18E+01 4.91E+01 3.19E+01 1.19E+02 -2.01 E+01 1.38E+02 1.53E+04 4.30E+02 1.38E+04 5.OOE+02 2.53E+01 3.66E+01 1.51E+01 4.30E+01 1.33E+03 1.26E+03 1.18E+03 1.43E+03 2.66E+01 9.84E+01 -9.87E+00 3.64E+02 3.43E+01 3.99E+01 5.43E+00 4.52E+01 Number of Samples Number of Positive IDs I Ind = Indicator Stations Cntl = Control Stations Page 1 of 1 I

TABLE A-9.1 GAMMA SPECTROMETRY RESULTS OF SEDIMENT Results in pCi/kilogram Station 33 Upstream Control Location & Date Station 33 3/25/2009 FNiciIie RQ A-Riiity Error MDA--] Location & Date Station 33 10/22/2009 F-Nu-cIidle RQ A-iivit-y Error MD-A--1 BE-7 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALAl140 BI-214 RA-226 1.35E+02 + + 1.71E+04+ 0.OOE+00 + 6.16E+00 + -5.32E-02 + 2.33E-01 + -9.92E+00 + -1.97E+01 + -8.45E+00 + 1.22E+00 + 3.68E+01 + 2.67E+00 + + 5.12E+02 + + 1.38E+03 + 1.81 E+02 1.06E+03 2.16E+02 2.04E+01 1.82E+01 4.58E+01 2.97E+01 6.38E+01 2.63E+01 1.97E+01 2.79E+01 2.25E+01 7.47E+01 6.05E+02 2.79E+02 3.69E+02 3.60E+02 3.25E+01 2.99E+01 7.52E+01 4.73E+01 1.02E+02 4.21 E+01 3.21 E+01 4.07E+01 3.60E+01 6.67E+01 8.02E+02 BE-7 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 BI-214 RA-226 1.63E+02 + + 1.69E+04 + -3.47E+01 + 1.19E+01 + 2.20E+00 + 2.44E+01 + -1.11E+00 + -3.08E+01 + -1.29E+01 + 5.33E-01 + + 5.18E+01 + -1.25E+01 + + 5.08E+02 + 1.03E+03 + 2.65E+02 1.28E+03 2.82E+02 2.73E+01 2.03E+01 7.74E+01 4.01 E+01 8.35E+01 3.46E+01 1.95E+01 3.25E+01 4.65E+01 9.27E+01 9.04E+02 4.12E+02 4.76E+02 4.60E+02 4.24E+01 3.28E+01 1.21 E+02 6.58E+01 1.32E+02 5.48E+01 3.20E+01 4.39E+01 7.31 E+01 9.35E+01 1.45E+03 Station 34 Downstream Indicator Location & Date Station 34 3/25/2009 FIN16-c-lidi- -RO Ac-tiv-!tV-- Error MD-A-BE-7 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 BI-214 RA-226 1.19E+02 + + 1.71E+04+ 5.51 E+01 + -8.90E-02 + -5.75E+00 + 3.75E-01 + 3.95E+00 + -3.06E+01 + -8.71 E+00 + 7.42E+00 + + 1.45E+02 + -2.84E+00 + + 4.94E+02 + 7.89E+02 + 1.67E+02 1.07E+03 1.77E+02 2.06E+01 2.31 E+01 6.56E+01 1.96E+01 7.29E+01 2.51 E+01 2.06E+01 3.37E+01 3.37E+01 7.82E+01 5.86E+02 2.54E+02 2.66E+02 2.84E+02 3.39E+01 3.69E+01 1.08E+02 3.12E+01 1.16E+02 3.99E+01 3.28E+01 3.08E+01 5.47E+01 7.69E+01 9.26E+02 Location & Date Station 34 10/22/2009 -Nu-clidie RO A-tiVity Error MD-A--- BE-7 1.18E+02 + 2.59E+02 4.08E+02 K-40 + 1.71E+04 + 1.33E+03 5.57E+02 CR-51 -7.57E+01 + 2.89E+02 4.67E+02 MN-54 2.17E+01 + 3.30E+01 5.05E+01 CO-58 3.43E+00 + 2.34E+01 3.76E+01 FE-59 2.19E+01 + 8.81E+01 1.40E+02 CO-60 -1.21 E+00 + 3.42E+01 5.60E+01 ZN-65 -2.41 E+01 + 8.80E+01 1.41 E+02 ZRNB-95 -1.50E+01 + 4.OOE+01 6.37E+01 CS-134 -1.14E+01 + 2.94E+01 4.66E+01 CS-137 + 1.71E+02 + 5.40E+01 5.22E+01 BALA140 0.OOE+00 + 4.48E+01 7.46E+01 BI-214 + 6.86E+02 + 1.03E+02 9.11E+01 RA-226 1.05E+03 + 9.25E+02 1.49E+03 RO = Results Qualifier. If blank, result is less than detection limit. If "+". result is above detection limit. Page 1 of 1

TABLE A-9.2 GAMMA SPECTROMETRY RESULTS OF SEDIMENT -

SUMMARY

Results in pCi/kilogram Average Activity Activity Average Number of Activity Low High MDA Samples Number of Positive IDs Nuclide BALA 140 BALA140 BE-7 BE-7 BI-214 BI-214 CO-58 CO-58 CO-60 CO-60 CR-51 CR-51 CS-134 CS-134 CS-137 CS-137 FE-59 FE-59 K-40 K-40 MN-54 MN-54 RA-226 RA-226 ZN-65 ZN-65 Ind Cnti Ind CntI Ind Cntl Ind CntI Ind CntI Ind Cntl Ind CntI Ind Cntl Ind CntI Ind CntI Ind CntI Ind Cnti Ind Cntl -1.42E+00 -4.89E+00 1.19E+02 1.49E+02 5.90E+02 5.1 OE+02 -1.16E+00 1.08E+00 1.37E+00 -5.51 E+00 -1.03E+01 -1.74E+01 -2.00E+00 8.77E-01 1.58E+02 4.43E+01 1.12E+01 1.23E+01 1.71 E+04 1.70E+04 1.08E+01 9.03E+00 9.19E+02 1.20E+03 -2.74E+01 -2.52E+01 -2.84E+00 -1.25E+01 1.18E+02 1.35E+02 4.94E+02 5.08E+02 -5.75E+00 -5.32E-02 -1.21 E+00 -9.92E+00 -7.57E+01 -3.47E+01 -1.14E+01 5.33E-01 1.45E+02 3.68E+01 3.75E-01 2.33E-01 1.71 E+04 1.69E+04 -8.90E-02 6.16E+00 7.89E+02 1.03E+03 -3.06E+01 -3.08E+01 0.OOE+00 2.67E+00 1.19E+02 1.63E+02 6.86E+02 5.12E+02 3.43E+00 2.20E+00 3.95E+00 -1.11E+00 5.51 E+01 0.00E+00 7.42E+00 1.22E+00 1.71 E+02 5.18E+01 2.19E+01 2.44E+01 1.71 E+04 1.71 E+04 2.17E+01 1.19E+01 1.05E+03 1.38E+03 -2.41 E+01 -1.97E+01 6.47E+01 5.45E+01 3.31 E+02 3.45E+02 8.40E+01 8.01E+01 3.73E+01 3.14E+01 4.36E+01 5.65E+01 3.76E+02 4.10E+02 3.97E+01 3.21 E+01 4.15E+01 4.23E+01 1.24E+02 9.83E+01 4.11E+02 4.23E+02 4.22E+01 3.75E+01 1.21 E+03 1.13E+03 1.28E+02 1.17E+02 I ZRNB-95 Ind ZRNB-95 Cnti -1.19E+01 -1.50E+01 -8.71 E+00 5.18E+01 -1.07E+01 -1.29E+01 -8.45E+00 4.85E+01 2 2 0 0 I U Ind = Indicator Stations Cntl = Control Stations Pagel1 of 1

TABLE A-10.1 GAMMA SPECTROMETRY RESULTS OF FISH Station 30 Columbia River - Station 38 Snake River Results in OCi/kilogram (wet) Location & Collection Species Date Nuclide RQ Activity Error MDA Steelhead 10/28/09 K-40 + 3.69E+03 + 3.07E+02 1.67E+02 Station 30 MN-54 7.17E+00 + 7.87E+00 1.12E+01 Indicator CO-58 1.33E+01 + 2.46E+01 3.81 E+01 FE-59 2.95E+01 + 1.26E+02 2.01 E+02 CO-60 7.55E+00 + 9.40E+00 1.39E+01 ZN-65 -1.34E+01 + 3.20E+01 5.06E+01 ZRNB-95 5.88E+00 + 2.87E+01 4.63E+01 CS-134 1.66E+00 + 9.30E+00 1.51E+01 CS-137 -3.08E+00 + 9.51E+00 1.52E+01 Bi-214 -2.64E+00 + 2.13E+01 3.53E+01 RA-226 -7.32E+01 + 2.79E+02 3.44E+02 White Fish 11/02/09 K-40 + 2.89E+03 + 2.84E+02 1.81 E+02 Station 30 MN-54 -3.83E+00 + 1.20E+01 1.91E+01 Indicator CO-58 1.60E+01 + 2.51E+01 3.83E+01 FE-59 -1.16E-01 + 1.14E+02 1.88E+02 CO-60 6.34E+00 + 1.04E+01 1.58E+01 ZN-65 -1.15E+01 + 3.25E+01 5.17E+01 ZRNB-95 -4.51E-01 + 2.67E+01 4.39E+01 CS-134 -1.65E+00 + 9.99E+00 1.62E+01 CS-137 5.06E+00 + 9.1OE+00 1.42E+01 Bi-214 -4.32E+00 + 2.61E+01 3.91E+01 RA-226 -5.98E+01 + 2.48E+02 3.35E+02 Sucker 11/02/09 K-40 + 3.33E+03 + 2.83E+02 1.69E+02 Station 30 MN-54 1.98E+00 + 1.02E+01 1.65E+01 Indicator CO-58 7.36E+00 + 2.12E+01 3.35E+01 FE-59 4.66E+01 + 1.19E+02 1.86E+02 CO-60 1.02E+01 + 1.09E+01 1.62E+01 ZN-65 -1.02E+01 + 2.90E+01 4.62E+01 ZRNB-95 -6.1OE+00 + 2.27E+01 3.62E+01 CS-134 2.74E+00 + 8.53E+00 1.36E+01 CS-137 9.83E+00 + 7.96E+00 1.14E+01 Bi-214 1.21E+01 + 1.80E+01 3.21E+01 RA-226 -1.27E+01 + 1.83E+02 3.07E+02 RO = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 1 of 2

I TABLE A-10.1 GAMMA SPECTROMETRY RESULTS OF FISH Station 30 Columbia River - Station 38 Snake River I Results in pCi/kilogram (wet) I Location & Collection Species Date Nuclide RQ Activity Error MDA Steelhead 11/03/09 K-40 + 2.53E+03 + 2.44E+02 1.55E+02 Station 38 MN-54 -2.75E-01 + 9.14E+00 1.50E+01 Control CO-58 0.OOE+00 + 1.89E+01 3.14E+01 FE-59 3.37E+01 + 1.01E+02 1.58E+02 CO-60 -6.44E-02 + 8.46E+00 1.39E+01 ZN-65 0.00E+00 + 3.82E+01 6.36E+01 ZRNB-95 4.53E+00 + 2.23E+01 3.58E+01 CS-134 -1.94E+00 + 8.39E+00 1.35E+01 CS-137 2.67E+00 + 7.43E+00 1.18E+01 Bi-214 6.94E+00 + 1.89E+01 3.38E+01 RA-226 -5.54E+01 + 2.45E+02 3.16E+02 Bass 11/12/09 K-40 + 3.88E+03 + 3.67E+02 2.54E+02 Station 38 MN-54 -2.57E+00 + 1.40E+01 2.26E+01 Control CO-58 6.22E+00 + 2.54E+01 4.08E+01 FE-59 -4.91E+01 + 1.36E+02 2.16E+02 CO-60 7.29E+00 + 1.35E+01 2.09E+01 ZN-65 -1.34E+01 + 3.32E+01 5.23E.+01 ZRNB-95 0.00E+00 + 3.22E+01 5.37E+01 CS-134 4.23E+00 + 1.43E+01 2.31E+01 CS-137 4.78E+00 + 1.20E+01 1.91E+01 Bi-214 4.72E+00 + 3.16E+01 5.78E+01 RA-226 -2.17E+02 + 5.34E+02 5.13E+02 5 Sucker 10/21/09 K-40 + 3.06E+03 + 2.73E+02 1.61 E+02 Station 38 MN-54 -2.31E+00 + 1.01E+01 1.61 E+01 Control CO-58 1.01 E+01 + 2.38E+01 3.74E+01 FE-59 -1.64E+01 + 1.14E+02 1.84E+02 CO-60 8.58E+00 + 8.93E+00 1.30E+01 ZN-65 4.55E+00 + 2.39E+01 3.84E+01 ZRNB-95 2.72E+00 + 2.96E+01 4.82E+01 CS-134 4.20E+00 + 8.80E+00 1.39E+01 CS-137 2.80E+00 + 7.38E+00 1.16E+01 Bi-214 1.44E+01 + 1.91E+01 3.35E+01 3 RA-226 -5.98E+01 + 2.34E+02 3.OOE+02 R I I RQ = Results Qualifier, If blank, result is less than detection limit, If "+", result is above detection limit. Page 2 of 2 I

TABLE A-10.2 GAMMA SPECTROMETRY RESULTS OF FISH Summary Results in pCi/kilogram (wet) Nuclide Bi-214 Bi-214 CO-58 CO-58 CO-60 CO-60 CS-1 34 CS-1 34 CS-137 CS-1 37 FE-59 FE-59 K-40 K-40 MN-54 MN-54 RA-226 RA-226 ZN-65 ZN-65 ZRNB-95 ZRNB-95 Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Ind Average Activity 1.70E+00 8.69E+00 1.22E+01 5.44E+00 8.02E+00 5.27E+00 9.15E-01 2.17E+00 3.94E+00 3.42E+00 2.53E+01 -1.06E+01 3.31 E+03 3.16E+03 1.77E+00 -1.72E+00 -4.86E+01 -1.11E+02 -1.17E+01 -2.96E+00 -2.24E-01 2.42E+00 Activity Activity Average Low High MDA -4.32E+00 1.21 E+01 3.55E+01 4.72E+00 1.44E+01 4.17E+01 7.36E+00 1.60E+01 3.66E+01 0.OOE+00 1.01 E+01 3.65E+01 6.34E+00 1.02E+01 1.53E+01 -6.44E-02 8.58E+00 1.59E+01 -1.65E+00 2.74E+00 1.50E+01 -1.94E+00 4.23E+00 1.69E+01 -3.08E+00 9.83E+00 1.36E+01 2.67E+00 4.78E+00 1.42E+01 -1.16E-01 4.66E+01 1.92E+02 -4.91 E+01 3.37E+01 1.86E+02 2.89E+03 3.69E+03 1.72E+02 2.53E+03 3.88E+03 1.90E+02 -3.83E+00 7.17E+00 1.56E+01 -2.57E+00 -2.75E-01 1.79E+01 -7.32E+01 -1.27E+01 3.29E+02 -2.17E--02 -5.54E+01 3.76E+02 -1.34E+01 -1.02E+01 4.95E+01 -1.34E+01 4.55E+00 5.15E+01 -6.1 OE+00 5.88E+00 4.21 E+01 0.OOE+00 4.53E+00 4.59E+01 Number of Number of Samples Positive IDs Ind = Indicator Stations Cntl = Control Stations Page I of I

TABLE A-1 1.1 IODINE 131 IN MILK Results in pCi/liter, decay corrected to sample collection time Station 9b Control Station 36 Indicator Collection 1-131 1-131 1-131 1-131 Date RO Activity Error MDA RQ Activity Error MDA 01/12/09 -6.29E-02 + 2.19E-01 3.56E-01 1.46E-01 + 1.86E-01 2.96E-01 02/23/09 -4.79E-02 + 2.44E-01 3.98E-01 2.66E-02 + 2.08E-01 3.40E-01 03/16/09 4.77E-02 + 2.53E-01 4.14E-01 1.85E-03 + 2.41E-01 3.96E-01 04/13/09 7.36E-02 + 2.14E-01 3.48E-01 -8.80E-02 + 2.20E-01 3.56E-01 04/27/09 -1.16E-01 + 2.53E-01 4.09E-01 3.85E-03 + 2.14E-01 3.51E-01 05/11/09 -1.07E-02 + 2.37E-01 3.89E-01 1.45E-01 + 2.05E-01 3.29E-01 05/18/09 7.58E-02 + 2.37E-01 3.85E-01 8.04E-02 + 2.24E-01 3.64E-01 06/08/09 -3.17E-02 + 2.38E-01 3.89E-01 7.70E-02 + 2.07E-01 3.36E-01 06/22/09 -9.92E-02 + 2.32E-01 3.75E-01 -2.53E-02 + 2.14E-01 3.51E-01 07/13/09 7.96E-03 + 2.30E-01 3.77E-01 -8.13E-02 + 2.13E-01 3.46E-01 07/27/09 -1.52E-03 + 2.25E-01 3.71E-01 1.22E-04 + 2.02E-01 3.42E-01 08/10/09 6.60E-02 + 2.61E-01 4.26E-01 3.98E-02 + 2.36E-01 3.86E-01 08/24/09 -1.35E-01 + 2.63E-01 4.25E-01 -1.85E-02 + 2.34E-01 3.84E-01 09/14/09 1.72E-02 + 1.80E-01 2.94E-01 9.92E-02 + 2.34E-01 3.79E-01 09/28/09 -1.54E-01 + 2.64E-01 4.25E-01 2.92E-02 + 2.25E-01 3.68E-01 10/12/09 -7.19E-03 + 2.28E-01 3.74E-01 -4.95E-02 + 1.66E-01 2.69E-01 11/16/09 -1.12E-01 + 2.59E-01 4.21E-01 1.90E-02 + 2.43E-01 3.98E-01 12/14/09 5.22E-02 + 1.60E-01 2.59E-01 -3.96E-02 + 1.92E-01 3.14E-01 TABLE A-1 1.2 IODINE 131 IN MILK Summary Results in pCi/liter, decay corrected to sample collection time Number Average Activity Activity Average Number Positive Location Activity Low High MDA Samples IDs I I I I ,I I I I I I I I I I I I Indicator-St 36 Control - St 9b 2.03E-02 -8.80E-02 1.46E-01 3.50E-01 3.80E-01 18 18 0 0 -2.43E-02 -1.54E-01 7.58E-02 RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 1 of 1

TABLE A-12.1 GAMMA SPECTROMETRY RESULTS OF MILK STATION 9b - CONTROL Results in pCi per liter Collection Date: 1/12/2009 -Nu-clide RQ A-tivity Err-or MDA--] Collection Date: 2/23/2009 FNu-clilde RQ Ac-tiVity Error MD-A----] BA-133 CO-60 ZN-65 MN-54 CS-1 34 CS-137 BALA140 K-40 FE-59 RA-226 ZRNB-95 BE-7 -8.11E-01 + 2.29E+00 + -9.OOE-01 + -9.80E-02 + -1.39E+00 + 6.84E-01 + 0.OOE+00 + + 1.46E+03 + 2.76E+00 + 1.73E-01 + -1.02E+00 + 2.17E+01 + 3.82E+00 4.04E+00 6.99E+00 3.15E+00 3.20E+00 3.14E+00 4.88E+00 1.18E+02 7.42E+00 7.75E+01 3.22E+00 2.37E+01 6.19E+00 6.30E+00 1.13E+01 5.16E+00 5.1OE+00 5.07E+00 8.14E+00 7.29E+01 1.16E+01 1.37E+02 5.16E+00 3.63E+01 BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA 140 K-40 FE-59 RA-226 ZRNB-95 BE-7 1.26E-02 + -7.94E-01 + -1.69E+00 + 6.59E-01 + -1.37E+00 + 5.01E-01 + -1.22E+00 + + 1.49E+03 + -1.85E+00 + -6.98E+00 + 8.98E-02 + 9.70E+00 + 3.11 E+00 3.81 E+00 7.40E+00 2.54E+00 2.86E+00 2.54E+00 4.63E+00 1.28E+02 8.1 OE+00 6.92E+01 2.28E+00 2.07E+01 5.11 E+00 6.12E+00 1.19E+01 4.03E+00 4.50E+00 4.07E+00 7.33E+00 8.09E+01 1.29E+01 1.09E+02 3.73E+00 3.24E+01 Collection Date: 3/16/2009 FNii-clide RQ Acivity Error MD-A---- Collection Date: 4/13/2009 FNu-clidle RQ A-iity Error MD-A BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA140 K-40 FE-59 RA-226 ZRNB-95 BE-7 2.OOE+00 + -1.64E+00 + -4.38E+00 + -7.44E-01 + -1.32E+00 + -4.41E-01 + 0.OOE+00 + + 1.45E+03 + 0.OOE+00 + 3.78E+00 + 5.94E-01 + -5.03E+00 + 2.18E+00 3.74E+00 8.73E+00 2.91 E+00 2.92E+00 2.25E+00 8.84E-01 1.23E+02 8.45E+00 5.78E+01 2.64E+00 1.93E+01 3.17E+00 5.85E+00 1.37E+01 4.65E+00 4:61 E+00 3.60E+00 1 ;47E+00 7.79E+01 1.41 E+01 1.04E+02 4.23E+00 3.08E+01 BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA 140 K-40 FE-59 RA-226 ZRNB-95 BE-7 FNu-clidl BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA140 K-40 FE-59 RA-226 ZRNB-95 BE-7 -1.32E+00 0.OOE+00 -1.57E+00 -8.82E-03 5.23E-03 -4.41 E-01 0.OOE+00 + 1.50E+03 1.80E+00 2.74E+00 8.80E-01 9.04E+00 + + 3.44E+00 5.21 E+00 7.56E+00 2.80E+00 2.05E+00 2.67E+00 3.79E+00 1.21 E+02 7.95E+00 5.65E+01 2.60E+00 2.09E+01 5.49E+00 8.68E+00 1.22E+01 4.60E+00 3.38E+00 4.30E+00 6.32E+00 6.76E+01 1.27E+01 1.02E+02 4.11E+00 3.28E+01 5/11/2009 M D-A---7 Collection Date: 4/27/2009 FNu-clidce RO A-i-vity Error MDFA--] Collection Date: RO Ac-tfiity Error BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA 40 K-40 FE-59 RA-226 ZRNB-95 BE-7 5.32E-01 + 4.75E-01 + 1.56E+00 + 0.OOE+00 + 9.95E-01 + -4.62E-01 + -4.01E-01 + + 1.45E+03 + 5.31 E-01 + -1.55E+00 + 3.29E-01 + 0.OOE+00 + 3.09E+00 2.74E+00 6.55E+00 2.60E+00 2.42E+00 2.89E+00 3.68E+00 1.19E+02 8.13E+00 5.91 E+01 2.40E+00 1.96E+01 5.OOE+00 4.39E+00 1.05E+01 4.33E+00 3.80E+00 4.66E+00 5.93E+00 6.91 E+01 1.33E+01 1.04E+02 3.87E+00 3.26E+01 3.20E-02 + -1.36E+00 + -7.20E-02 + -1.30E+00 + 1.60E+00 + -6.85E-01 + 3.11E+00 + + 1.41E+03 + -1.49E-01 _+ 2.61 E+01 + -9.19E-02 + 1.56E+00 + 2.15E+00 4.21 E+00 8.23E+00 2.88E+00 3.12E+00 3.13E+00 3.69E+00 1.19E+02 8.08E+00 6.03E+01 2.34E+00 1.93E+01 3.52E+00 6.70E+00 1.35E+01 4.49E+00 4.91 E+00 5.04E+00 5.12E+00 7.18E+01 1.33E+01 1.06E+02 3.83E+00 3.14E+01 RQ = Results Qualifier. If blank, result is less than detection limit. If "+". result is above detection limit. Page 1 of 6

TABLE A-12.1 GAMMA SPECTROMETRY RESULTS OF MILK STATION 9b - CONTROL Results in pCi per liter I I Collection Date: 5/18/2009 FNiiclide-RQ Acivity Error MD-A-- Collection Date: 6/8/2009 Nu-clie RI Ac-tiRity Error MDA-* BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA 40 K-40 FE-59 RA-226 ZRNB-95 BE-7 1.00E+00 + 1.87E+00 + -1.43E+00 + -7.38E-01 + 5.33E-01 + 0.OOE+00 + 0.OOE+00 + + 1.51E+03 + 1.68E+00 + -3.56E+00 + 1.61 E+00 + -6.81 E+00 + 3.70E+00 3.56E+00 7.03E+00 3.20E+00 2.79E+00 3.1OE+00 3.78E+00 1.24E+02 8.55E+00 6.93E+01 2.60E+00 2.36E+01 5.96E+00 5.49E+00 1.13E+01 5.13E+00 4.50E+00 5.17E+00 6.29E+00 7.12E+01 1.37E+01 1.15E+02 3.95E+00 3.78E+01 BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA140 K-40 FE-59 RA-226 ZRNB-95 BE-7 -6.53E-01 + 3.42E+00 + 1.92E-01 + 1.19E-02 + -4.38E-01 + -3.21 E-02 + -8.98E-01 + + 1.60E+03 + -2.57E+00 + 4.47E+00 + 1.29E+00 + 1.37E+01 + 3.05E+00 3.61 E+00 6.02E+00 2.75E+00 2.78E+00 2.28E+00 4.56E+00 1.24E+02 8.23E+00 6.33E+01 2.98E+00 1.91 E+01 4.93E+00 5.27E+00 9.85E+00 4.52E+00 4.50E+00 3.74E+00 7.29E+00 6.57E+01 1.30E+01 1.12E+02 4.68E+00 2.88E+01 Collection Date: 6/22/2009 FNii~lide RO A-itity Error MD-A--- Collection Date: 7/13/2009 FNu-clidle RO Ac-iiity Error MD-A--] BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA1 40 K-40 FE-59 RA-226 ZRNB-95 BE-7 1.25E+00 + -5.18E-01 + 2.03E+00 + 1.52E+00 + -1.12E+00 + 1.79E+00 + 2.10E+00 + + 1.55E+03 + 3.33E+00 + 2.46E+01 + 1.27E+00 + 6.36E+00 + 3.87E+00 3.87E+00 7.87E+00 2.68E+00 3.17E+00 3.13E+00 3.25E+00 1.22E+02 7.95E+00 5.97E+01 2.73E+00 1.54E+01 6.22E+00 6.27E+00 1.26E+01 4.1OE+00 5.07E+00 4.85E+00 4.69E+00 6.51 E+01 1.23E+01 1.05E+02 4.25E+00 2.39E+01 BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA 140 K-40 FE-59 RA-226 ZRNB-95 BE-7 -1.18E+00 + 2.60E+00 + -2.10E+00 + -1.99E-02 + 6.42E-01 + 2.03E+00 + 0.OOE+00 + + 1.52E+03 + -3.04E-01 + -2.52E+01 + 1.42E+00 + -6.42E-01 + 3.07E+00 3.84E+00 7.15E+00 2.72E+00 2.53E+00 2.63E+00 3.61 E+00 1.24E+02 8.88E+00 1.07E+02 3.04E+00 2.02E+01 4.88E+00 5.84E+00 1.14E+01 4.46E+00 4.06E+00 3.90E+00 6.01 E+00 7.12E+01 1.45E+01 1.18E+02 4.76E+00 3.31 E+01 3 I I I I I I I I I I I I I Collection Date: 7/27/2009 FN zlidle RO Ac-ctlity Error MDA-] Collection Date: 8/10/2009 FNu-clidie RQ A-ciivity Error MD-A-BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA 140 K-40 FE-59 RA-226 ZRNB-95 BE-7 1.50E-01 + 1.44E-01 + -1.27E+00 + 3.44E-01 + 0.OOE+00 + -2.57E-01 + -9.70E-01 + + 1.48E+03 + -1.44E+00 + -1.41 E+00 + -1.22E-02 + -5.23E+00 + 3.22E+00 3.53E+00 6.44E+00 3.04E+00 3.48E+00 2.73E+00 4.OOE+00 1.21 E+02 9.27E+00 6.46E+01 2.52E+00 2.39E+01 5.27E+00 5.78E+00 1.03E+01 4.94E+00 5.79E+00 4.44E+00 6.32E+00 6.84E+01 1.50E+01 1.12E+02 4.14E+00 3.85E+01 BA-1 33 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA140 K-40 FE-59 RA-226 ZRNB-95 BE-7 1.56E+00 + 5.30E-01 + 2.02E+00 + -7.12E-02 + -6.33E-01 + 3.56E-01 + 2.70E-01 + + 1.45E+03 + -2.86E+00 + 4.24E+00 + -1.03E-01 + 4.81 E+00 + 3.75E+00 3.56E+00 6.86E+00 2.59E+00 2.64E+00 2.88E+00 3.55E+00 1.20E+02 9.40E+00 6.14E+01 2.82E+00 2.35E+01 5.98E+00 5.75E+00 1.09E+01 4.24E+00 4.25E+00 4.67E+00 5.75E+00 6.96E+01 1.49E+01 1.10E+02 4.62E+00 3.79E+01 I I I RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 2 of 6

TABLE A-12.1 GAMMA SPECTROMETRY RESULTS OF MILK STATION 9b - CONTROL Results in pCi per liter Collection Date: 8/24/2009 FNu-clid-e RO ActiVity Error MD-A--] Collection Date: 9/14/2009 7Nu-clicIe RQ A-cti ity Error MD`A---ý BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA140 K-40 FE-59 RA-226 ZRNB-95 BE-7 1.60E+00 + 1.36E+00 + 3.94E+00 + -1.17E+00 + 1.65E+00 + 2.OOE-01 + -6.88E-01 + + 1.64E+03 + 4.53E+00 + 2.68E+01 + 1.12E-02 + 5.42E+00 + 3.03E+00 3.62E+00 6.65E+00 3.57E+00 2.70E+00 2.57E+00 3.99E+00 1.29E+02 8.71 E+00 6.19E+01 3.03E+00 2.37E+01 4.74E+00 5.70E+00 1.02E+01 5.70E+00 4.18E+00 4.18E+00 6.37E+00 7.33E+01 1.34E+01 1.08E+02 4.98E+00 3.81 E+01 BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA 40 K-40 FE-59 RA-226 ZRNB-95 BE-7 -1.15E-01 1.82E+00 0.OOE+00 5.48E-01 -6.25E-01 -5.90E-01 -6.14E-02 + 1.45E+03 -8.25E-02 -9.31 E+00 -9.37E-01 -6.93E+00 + + + -+ +.} -+ +I 3.59E+00 3.34E+00 1.40E+01 2.65E+00 2.77E+00 3.11 E+00 3.43E+00 1.24E+02 6.58E+00 7.65E+01 2.82E+00 2.33E+01 5.89E+00 5.12E+00 2.33E+01 4.25E+00 4.45E+00 5.01 E+00 5.61 E+00 7.73E+01 1.08E+01 1.15E+02 4.47E+00 3.73E+01 Collection Date: 9/28/2009 FN--clide RQ Activity Error MDA ] Collection Date: 10/12/2009 FNu-clid e RQ A-ctivity Error MDA 1 BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA140 K-40 FE-59 RA-226 ZRNB-95 BE-7 2.16E+00 + -9.85E-01 + -4.55E-02 + -3.50E-01 + -1.61 E+00 + -1.66E+00 + 2.05E-01 + + 1.41E+03+ -8.74E-02 + -2.77E+01 + -3.76E-01 + 7.20E+00 + 2.97E+00 4.04E+00 6.92E+00 2.52E+00 3.18E+00 3.36E+00 2.95E+00 1.20E+02 7.70E+00 1.16E+02 2.65E+00 2.10E+01 4.56E+00 6.49E+00 1.14E+01 4.07E+00 5.02E+00 5.27E+00 4.78E+00 7.24E+01 1.26E+01 1.22E+02 4.29E+00 3.34E+01 BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA140 K-40 FE-59 RA-226 ZRNB-95 BE-7 -5.09E-01 8.65E-01 7.93E-01 ,-1.35E+00 -1.42E-01 1.24E+00 -1.49E+00 + 1.41E+03 -6.09E-02 -1.56E+01 -1.11E+00 1.57E+00 + + + + 2.40E+00 3.23E+00 6.92E+00 3.29E+00 2.72E+00 3.07E+00 4.23E+00 1.15E+02 8.49E+00 8.51 E+01 3.20E+00 1.79E+01 3.86E+00 5.12E+00 1.12E+01 5.20E+00 4.45E+00 4.84E+00 6.58E+00 6.25E+01 1.39E+01 1.14E+02 5.08E+00 2.91E+01 Collection Date: 11/16/2009 FNu-clide RQ Acivity Error MDPA--- Collection Date: 12/14/2009 -Nu-clide RQ Activity Error MD-A---] BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA 40 K-40 FE-59 RA-226 ZRNB-95 BE-7 -9.13E-02 + 2.18E+00 + 1.36E+00 + -9.82E-02 + -6.60E-01 + -8.69E-01 + -8.15E-01 + + 1.45E+03 + -1.10E-01 + -3.30E+01 + -7.59E-01 + 3.67E+00 + 3.48E+00 3.76E+00 6.14E+00 2.87E+00 2.83E+00 3.26E+00 3.52E+00 1.19E+02 6.06E+00 1.17E+02 2.94E+00 2.40E+01 5.70E+00 5.79E+00 9.81 E+00 4.70E+00 4.56E+00 5.22E+00 5.55E+00 6.70E+01 9.93E+00 1.13E+02 4.70E+00 3.89E+01 BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA140 K-40 FE-59 RA-226 ZRNB-95 BE-7 -2.09E+00 + 1.11E+00 + -1.82E+00 + 2.54E-01 + 1.83E-01 + -2.60E-01 + -7.83E-01 + + 1.40E+03 + 3.64E+00 + 5.81 E+00 + 1.34E-01 + -6.56E+00 + 3.69E+00 3.62E+00 7.66E+00 2.35E+00 3.07E+00 2.68E+00 3.48E+00 1.19E+02 8.24E+00 6.21 E+01 2.62E+00 2.43E+01 5.81 E+00 5.74E+00 1.23E+01 3.81 E+00 5.03E+00 4.36E+00 5.51 E+00 7.32E+01 1.28E+01 1.11E+02 4.29E+00 3.90E+01 RQ = Results Qualifier. If blank, result is less than detection limit. If "+". result is above detection limit. Page 3 of 6

TABLE A-12.1 GAMMA SPECTROMETRY RESULTS OF MILK STATION 36 - INDICATOR Results in pCi per liter Collection Date: 1/12/2009 FNucliad_ RQ Acivity Error -MDA---] BA-133 -1.54E+00 + 4.46E+00 7.20E+00 CO-60 2.19E+00 + 3.63E+00 5.61 E+00 ZN-65 -2.76E+00 + 6.55E+00 1.03E+01 MN-54 1.67E+00 + 2.73E+00 4.21 E+00 CS-134 -6.66E-01 + 2.66E+00 4.28E+00 CS-137 -7.80E-01 + 3.49E+00 5.64E+00 BALA140 -3.95E-01 + 3.86E+00 6.25E+00 K-40 + 1.62E+03 + 1.29E+02 8.37E+01 FE-59 -5.39E+00 + 9.86E+00 1.54E+01 RA-226 -3.15E+00 + 8.11 E+01 1.38E+02 ZRNB-95 1.08E+00 + 2.88E+00 4.57E+00 BE-7 1.06E+01 + 2.45E+01 3.91 E+01 Collection Date: 2/23/2009 -Nu-liae RQ A-ti~iiyj Error MDA--7 BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA140 K-40 FE-59 RA-226 ZRNB-95 BE-7 1.62E+00 + 2.25E-01 + 1.25E+00 + 8.59E-02 + -1.12E+00 + -3.78E-02 + -4.03E-01 + + 1.43E+03 + -3.60E-01 + -9.37E+00 + 1.84E+00 + -3.80E-01 + 2.74E+00 3.17E+00 6.41 E+00 2.78E+00 2.64E+00 2.57E+00 3.23E+00 1.21 E+02 8.15E+00 7.40E+01 2.79E+00 1.91 E+01 4.25E+00 5.16E+00 1.03E+01 4.56E+00 4.17E+00 4.22E+00 5.18E+00 7.33E+01 1.33E+01 1.12E+02 4.25E+00 3.13E+01 Collection Date: 3/16/2009 FNu-clidle RQ Acii-ity Error MD-A--- BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA 40 K-40 FE-59 RA-226 ZRNB-95 BE-7 -2.51 E-02 + -8.55E-01 + 8.70E-02 + 8.32E-01 + 2.15E-01 + -5.17E-01 + -3.21 E-01 + + 1.39E+03 + 1.99E+00 + -1.02E+01 + 5.92E-01 + 1.62E+00 + 3.50E+00 4.28E+00 7.98E+00 3.23E+00 4.05E+00 3.59E+00 4.22E+00 1.22E+02 7.09E+00 7.32E+01 2.94E+00 2.20E+01 5.75E+00 6.91 E+00 1.31 E+01 5.18E+00 6.63E+00 5.82E+00 6.87E+00 7.73E+01 1.12E+01 1.09E+02 4.73E+00 3.60E+01 Collection Date: 4/13/2009 FNiiClile RQ Ac-tivity Error* MDAf BA-133 1.40E+00 + 3.15E+00 4.99E+00 CO-60 -5.57E-01 + 3.29E+00 5.30E+00 ZN-65 0.OOE+00 + 9.22E+00 1.54E+01 MN-54 7.27E-01 + 2.53E+00 4.01E+00 CS-134 1.69E-01 + 2.51E+00 4.11E+00 CS-137 -7.OOE-01 + 3.26E+00 5.24E+00 BALA140 -1.63E+00 + 4.06E+00 6.27E+00 K-40 + 1.39E+03 + 1.23E+02 7.86E+01 FE-59 -1.67E-01 + 7.63E+00 1.25E+01 RA-226 -4.62E+01 + 1.52E+02 1.11E+02 ZRNB-95 -1.09E-01 + 2.88E+00 4.72E+00 BE-7 1.02E+01 + 2.30E+01 3.64E+01 I I I I I I I I I I I I I I I I I I Collection Date: 4/27/2009 FNu-cliidi RQ Activity Error MD-A---7 7NuI-lide Collection Date: RQ A--itiiity Error_ 5/11/2009 MID-A---- BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA 140 K-40 FE-59 RA-226 ZRNB-95 BE-7 1.25E-02 + 1.28E-01 + -3.04E+00 + 7.78E-01 + 7.82E-01 + -2.73E-01 + 9.14E-01 + + 1.61E+03 + 2.59E+00 + 2.44E+01 + 4.61 E-01 + 2.86E+00 + 2.25E+00 3.28E+00 7.06E+00 2.53E+00 2.59E+00 2.76E+00 3.86E+00 1.26E+02 7.86E+00 6.08E+01 2.84E+00 2.06E+01 3.70E+00 5.37E+00 1.11E+01 4.OOE+00 4.12E+00 4.48E+00 6.1OE+00 7.05E+01 1.24E+01 1.07E+02 4.58E+00 3.34E+01 BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA 40 K-40 FE-59 RA-226 ZRNB-95 BE-7 1.08E+00 + 1.64E+00 + -1.43E+00 + 1.11E+00 + -1.17E+00 + 3.90E-01 + 0.OOE+00 + + 1.38E+03 + 1.93E+00 + -6.40E+00 + -4.47E-02 + -6.62E+00 + 2.54E+00 3.75E+00 7.51 E+00 2.49E+00 2.78E+00 2.86E+00 6.24E+00 1.20E+02 8.57E+00 6.68E+01 2.55E+00 2.57E+01 3.99E+00 5.86E+00 1.21E+01 3.86E+00 4.40E+00 4.63E+00 1.04E+01 7.54E+01 1.37E+01 1.07E+02 4.19E+00 4.14E+01 RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 4 of 6

TABLE A-12.1 GAMMA SPECTROMETRY RESULTS OF MILK STATION 36 - INDICATOR Results in pCi per liter Collection Date: 5/18/2009 FNi-dicidie RQ -A-cti-ity Error MD-A--- Collection Date: 6/8/2009 FNUci e RQ oAdtifity. Errort MD-A--- BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA140 K-40 FE-59 RA-226 ZRNB-95 BE-7 -1.32E+00 + .9.14E-01 + 0.OOE+00 + -7.03E-01 + -2.16E-01 + -4.49E-02 + -9.37E-02 + + 1.72E+03 + 0.OOE+00 + -3.06E+00 + 2.24E+00 + -4.05E+00 + 3.75E+00 3.77E+00 6.88E+00 2.93E+00 3.14E+00 2.48E+00 3.82E+00 1.28E+02 8.35E+00 6.65E+01 2.80E+00 2.OOE+01 6.01 E+00 6.03E+00 1.15E+01 4.69E+00 5.13E+00 4.06E+00 6.26E+00 6.55E+01 1.39E+01 1.12E+02 4.18E+00 3.22E+01 BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA 140 K-40 FE-59 RA-226 ZRNB-95 BE-7 1.42E+00 + -1.96E-01 + -2.12E+00 + -1.64E-01 + 1.65E+00 + 0.OOE+00 + 0.OOE+00 + + 1.54E+03 + -1.95E+00 + -2.23E+01 + .9.58E-04 + 1.31 E+01 + 3.26E+00 3.84E+00 7.87E+00 2.54E+00 2.52E+00 2.46E+00 7.97E-01 1.24E+02 9.13E+00 9.96E+01 2.69E+00 2.41 E+01 5.17E+00 6.28E+00 1.26E+01 4.14E+00 3.87E+00 4.09E+00 1.33E+00 7.05E+01 1.46E+01 1.17E+02 4.43E+00 3.77E+01 Collection Date: 6/22/2009 -Nu-clicle RQ Acii6iity Error MDA Collection Date: 7/13/2009 FNu-clid6 R-Q A-ctiiity Er-r-r MD-A--] BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA 140 K-40 FE-59 RA-226 ZRNB-95 BE-7 1.94E+00 + 0.OOE+00 + -2.25E+00 + -7.18E-01 + 8.13E-01 + -4.51E-01 + -1.32E+00 + + 1.51E+03+ 3.57E+00 + -1.59E+01 + 1.63E-01 + -3.49E+00 + 3.35E+00 4.57E+00 8.05E+00 2.67E+00 2.OOE+00 2.82E+00 3.90E+00 1.21 E+02 7.1OE+00 8.84E+01 1.94E+00 2.19E+01 5.25E+00 7.62E+00 1.29E+01 4.25E+00 3.11E+00 4.56E+00 6.09E+00 6.75E+01 1.08E+01 1.17E+02 3.14E+00 3.54E+01 BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA1 40 K-40 FE-59 RA-226 ZRNB-95 BE-7 4.09E-02 + 2.06E+00 + -1.02E+00 + 2.94E-01 + -6.37E-01 + 7.97E-01 + -6.88E-01 + + 1.40E+03 + -2.56E+00 + 1,.29E+01 + -1.40E-01 + 9.09E+00 + 3.39E+00 3.71 E+00 7.30E+00 2.59E+00 2.73E+00 2.60E+00 3.20E+00 1.21 E+02 8.06E+00 6.18E+01 2.63E+00 1.99E+01 5.56E+00 5.72E+00 1.18E+01 4.20E+00 4.38E+00 4.11 E+00 5.05E+00 7.45E+01 1.27E+01 1.10E+02 4.29E+00 3.12E+01 Collection Date: 7/27/2009 FNu-clile6 RQ Ac-tiViity Error MD-A--- Collection Date: 8/10/2009 7Nu-clide RQ A-tiifi-y Erro-r . MD-A-BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA 40 K-40 FE-59 RA-226 ZRNB-95 BE-7 -7.43E-01 + 3.37E+00 + 1.27E+00 + -1.82E-01 + 8.98E-02 + -9.59E-01 + -1.07E+00 + + 1.52E+03 + 8.37E-01 + -3.88E+00 + 1.65E+00 + -2.13E-01 + 3.53E+00 3.40E+00 6.89E+00 2.73E+00 2.09E+00 3.19E+00 3.81 E+00 1.23E+02 7.69E+00 6.75E+01 2.85E+00 2.25E+01 5.71 E+00 4.89E+00 1.11E+01 4.46E+00 3.42E+00 5.08E+00 5.98E+00 6.87E+01 1.25E+01 1.12E+02 4.39E+00 3.69E+01 BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA 40 K-40 FE-59 RA-226 ZRNB-95 BE-7 1.58E-02 + 6.51 E-02 + -1.05E+00 + 7.15E-01 + -1.20E+00 + 3.13E-01 + 8.19E-01 + + 1.59E+03 + 2.23E+00 + -2.65E+01 + 0.OOE+00 + 7.14E+00 + 2.94E+-i00 3.54E+00 5.93E+00 2.88E+00 3.27E+00 3.46E+00 3.44E+00 1.27E+02 8.02E+00 1.04E+02 3.87E+00 2.11E+01 4.83E+00 5.81 E+00 9.53E+00 4.61 E+00 5.22E+00 5.64E+00 5.41 E+00 7.19E+01 1.27E+01 1'13E+02 6.45E+00 3.35E+01 RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 5 of 6

TABLE A-12.1 GAMMA SPECTROMETRY RESULTS OF MILK STATION 36 - INDICATOR Results in pCi per liter Collection Date: 8/24/2009 FNu-clie RQ Ac-tiiify Error MD-A--7 Collection Date: 9/14/2009 FNu-iliile RQ Ac-ti~ity Error

  • MD-A---7 BA-133 CO-60 ZN-65 MN-54 CS-1 34 CS-137 BALA 40 K-40 FE-59 RA-226 ZRNB-95 BE-7 1.16E+00 +

-2.69E-01 + -1.38E+00 + -6.41E-01 + -9.05E-01 + 1.06E+00 + 7.79E-02 + + 1.35E+03 + -2.70E+00 + 3.37E+00 + -4.93E-01 + 0.OOE+00 + 2.82E+00 3.20E+00 6.85E+00 2.88E+00 2.94E+00 2.38E+00 2.89E+00 1.17E+02 9.1OE+00 6.42E+01 3.02E+00 2.52E+01 4.46E+00 5.20E+00 1.10E+01 4.62E+00 4.70E+00 3.68E+00 4.72E+00 7.24E+01 1.44E+01

1. 1,4E+02 4.88E+00 4.19E+01 BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA140 K-40 FE-59 RA-226 ZRNB-95 BE-7

-1.31 E+00 + 7.92E-02 + 3.57E+00 + -5.26E-01 + 0.OOE+00 + -1.52E-01 + -1.65E+00 + + 1.37E+03 + -1.11E-01 + 2.63E+01 + 0.OOE+00 + 9.49E+00 + 3.60E+00 3.37E+00 7.41 E+00 2.43E+00 3.34E+00 2.35E+00 4.49E+00 1.17E+02 7.93E+00 6.41 E+01 3.86E+00 2.18E+01 5.76E+00 5.53E+00 1.16E+01 3.89E+00 5.57E+00 3.83E+00 7.01 E+00 7.03E+01 1.30E+01 1.12E+02 6.44E+00 3.43E+01 Collection Date: 9/28/2009 FNi-cliae RQ Activity Error MD-A----] Collection Date: 10/12/2009 -Nu-clidie RQ Ac-iit-y Err-or MD-A--- BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA 40 K-40 FE-59 RA-226 ZRNB-95 BE-7 0.OOE+00 + 0.OOE+00 + -2.35E-01 + 1.69E+00 + -1.42E-01 + 1.23E+00 + -2.85E-01 + + 1.56E+03 + 1.06E-01 + -1.32E+01 + 1.60E+00 + 2.42E-01 + 3.71 E+00 4.32E+00 6.65E+00 2.23E+00 2.87E+00 3.OOE+00 3.61 E+00 1.22E+02 7.54E+00 7.76E+01 2.81 E+00 2.20E+01 6.1-9E+00 7.20E+00 1.09E+01 3.24E+00 4.70E+00 4.72E+00 5.85E+00 6.49E+01 1.24E+01 1.09E+02 4.32E+00 3.61 E+01 BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA140 K-40 FE-59 RA-226 ZRNB-95 BE-7 1.17E+00 + 4.35E+00 + -3.42E+00 + 0.OOE+00 + -9.37E-01 + -3.45E-02 + -6.33E-02 + + 1.45E+03 + 3.92E+00 + -1.26E+01 + 2.67E-01 + -7.70E+00 + 3.20E+00 3.52E+00 8.62E+00 2.87E+00 2.85E+00 2.97E+00 3.87E+00 1.21 E+02 8.08E+00 8.75E+01 2.53E+00 2.34E+01 5.1OE+00 4.90E+00 1.37E+01 4.78E+00 4.55E+00 4.87E+00 6.35E+00 7.05E+01 1.24E+01 1.22E+02 4.1OE+00 3.73E+01 I I I I I I i I I I I I I I I I I I I Collection Date: FNu-clidle RQ Ac-iity Error BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA140 K-40 FE-59 RA-226 ZRNB-95 BE-7 -1.13E+00 + 1.72E+00 + 5.12E-02 + 6.21E-01 + -3.61E-01 + 3.35E-01 + 6.92E-01 + + 1.45E+03 + 3.1OE+00 + -6.24E+00 + -8.09E-01 + 0.OOE+00 + 3.71 E+00 3.60E+00 5.53E+00 2.76E+00 2.84E+00 2.89E+00 3.64E+00 1.20E+02 8.31 E+00 6.68E+01 3.09E+00 2.59E+01 11/16/2009 MD-A---7 5.97E+00 5.59E+00 9.08E+00 4.42E+00 4.62E+00 4.70E+00 5.79E+00 6.83E+01 1.30E+01 1.07E+02 4.95E+00 4.31E+01 Collection Date: 12/14/2009 FNu5-cIide RQ Ac-ti iity Error MDA---j BA-133 CO-60 ZN-65 MN-54 CS-134 CS-137 BALA140 K-40 FE-59 RA-226 ZRNB-95 BE-7 1.58E+00 + 3.77E+00 + -3.31 E+00 + 1.03E+00 + 0.OOE+00 + 1.79E-01 + -2.59E-01 + + 1.55E+03 + -1.77E+00 + -3.77E+00 + 5.25E-02 + 1.32E+01 + 3.27E+00 3.49E+00 7.58E+00 2.55E+00 2.87E+00 2.93E+00 3.18E+00 1.23E+02 7.97E+00 6.99E+01 2.97E+00 2.17E+01 5.16E+00 4.97E+00 1.19E+01 3.97E+00 4.79E+00 4.79E+00 5.15E+00 6.91 E+01 1.27E+01 1.16E+02 4.88E+00 3.37E+01 RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 6 of 6

TABLE A-12.2 GAMMA SPECTROMETRY RESULTS OF MILK -

SUMMARY

Results in pCi per liter Nuclide BA-133 BA-133 BALA 140 BALA 40 BE-7 BE-7 C0-60 C0-60 CS-134 CS-134 CS-137 CS-137 FE-59 FE-59 K-40 K-40 MN-54 MN-54 RA-226 RA-226 ZN-65 ZN-65 ZRNB-95 ZRNB-95 Ind Cntl Ind Cntl Ind Cntl Ind Cntl Ind Cntl Ind Cntl Ind Cntl Ind Cntl Ind Cntl Ind Cntl Ind Cntl Ind Cntl Average Activity 2.98E-01 1.96E-01 -3.15E-01 -9.1 OE-02 3.06E+00 2.97E+00 1.04E+00 7.43E-01 -2.02E-01 -2.06E-01 1.98E-02 6.13E-02 2.92E-01 4.87E-01 1.49E+03 1.48E+03 3.68E-01 -1.45E-01 -6.43E+00 -1.43E+00 -8.77E-01 -1.88E-01 4.63E-01 1.79E-01 Activity Activity Low High -1.54E+00 1.94E+00 -2.09E+00 2.166E+00 -1.65E+00 9.14E-01 -1.49E+00 3.11 E+00 -7.70E+00 1.32E+01 -6.93E+00 2.177E+01 -8.55E-01 4.35E+00 -1.64E+00 3.42E+00 -1.20E+00 1.65E+00 -1.61 E+00 1.65E1+00 -9.59E-01 1.23E+00 -1.66E+00 2.03E+00 -5.39E+00 3.92E+00 -2.86E+00 4.53E+00 1.35E+03 1.72E+03 1.40E+03 1.64E+03 -7.18E-01 1.69E+00 -1.35E+00 1.52E+00 -4.62E+01 2.63E+01 -3.30E+01 2.68E+01 -3.42E+00 3.57E+00 -4.38E+00 3.94E+00 -8.09E-01 2.24E+00 -1.11E+00 1.611E+00 Number Average of MDA Samples 5.00E+00 18 4.86E+00 18 5.58E+00 18 5.53E+00 18 3.42E+01 18 3.22E+01 18 5.47E+00 18 5.60E+00 18 4.30E+00 18 4.32E+00 18 4.43E+00 18 4.34E+00 18 1.23E+01 18 1.24E+01 18 6.80E+01 18 6.72E+01 18 4.06E+00 18 4.34E+00 18 1.08E+02 18 1.06E+02 18 1.10E+01 18 1.15E+01 18 4.39E+00 18 4.16E+00 18 Number of Positive IDs Ind = Indicator Stations Cntl = Control Locations Page 1 of1

TABLE A-15.1 GAMMA SPECTROMETRY RESULTS OF ROOTS Results in pCi/ kilogram (wet) Station 37 is Indicator - Station 9c is Control Station 37 Onion collected 6/17/2009 FNuclide RQ Activity Error MD-A--7 Station 9c Onion collected Error K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA 40 + 1.75E+03 + -7.42E-01 + -7.64E-01 + 2.01 E+00 + 4.29E+00 + -5.47E+00 + -1.95E-01 + 3.32E+00 + 7.42E-01 + -1.55E+00 + 8.68E-01 + 2.41 E+02 5.21 E+00 4.64E+00 2.11E+01 7.42E+00 1.56E+01 6.09E+00 4.31 E+00 4.64E+00 6.29E+00 5.73E+00 1.45E+02 8.32E+00 7.35E+00 3.42E+01 1.09E+01 2.41 E+01 9.97E+00 6.17E+00 7.40E+00 9.93E+00 8.97E+00 FN-UlCle -R0 Ac-tivity K-40 + 1.14E+0 MN-54 0.OOE+0 CO-58 -1.75E+0 FE-59 -5.41 E+0 CO-60 -8.85E-0 ZN-65 1.88E-0 ZRNB-95 7.50E-0 1-131 1.69E+0 CS-134 0.OOE+0 CS-137 -8.32E-0 BALA140 0.OOE+0 E-rror 6/17/2009 MDA ] 3 + 0+ 0+ 0+ 1+ 1+ 1+ 0+ 0+ 1+ 0+ 2.09E+02 1.16E+01 6.60E+00 1.86E+01 8.87E+00 1.61 E+01 5.68E+00 5.30E+00 7.85E+00 6.77E+00 2.78E+00 1.39E+02 1.93E+01 1.03E+01 2.88E+01 1.43E+01 2.64E+01 9.1OE+00 8.31 E+00 1.31 E+01 1.09E+01 4.63E+00 Station 37 Potato collected 7/20/2009 FNiuclide RQ Activity Error MDA K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA 40 + 3.93E+03 +

  • 1.05E+00 +

8.87E-02 + -3.1OE+00 + 1.79E+00 + -7.50E-01 + 1.44E-01 + 1.11E+00 + -1.31 E-01 + -4.42E-02 + -7.05E-01 + 3.24E+02 5.69E+00 5.11E+00 2.34E+01 8.29E+00 1.37E+01 5.30E+00 5.44E+00 4.12E+00 4.80E+00 6.11 E+00 1.19E+02 9.08E+00 8.38E+00 3.78E+01 1.32E+01 2.23E+01 8.68E+00 8.73E+00 6.73E+00 7.88E+00 9.73E+00 Station 37 Potato collected 8/17/2009 FN uclide RQ Activity Error MDA Station 9c Potato collected 7/20/2009 [kNuclide RO Activity Error MDA K-40 + 3.95E+03 + 3.23E+02 1.08E+02 MN-54 -1.16E+00 + 5.60E+00 8.89E+00 CO-58 -7.34E-03 + 5.58E+00 9.18E+00 FE-59 -6.34E+00 + 2.25E+01 3.56E+01 CO-60 2.42E+00 + 8.45E+00 1.33E+01 ZN-65 -4.22E+00 + 1.57E+01 2.48E+01 ZRNB-95 -2.94E+00 + 5.23E+00 7.76E+00 1-131 1.63E-02 + 4.84E+00 7.95E+00 CS-134 3.57E-01 + 4.80E+00 7.81E+00 CS-137 3.63E-02 + 5.51 E+00 9.05E+00 BALA140 -2.40E+00 + 7.87E+00 1.21 E+01 Station 9c Potato collected 8/17/2009 7Nuciide RO Activity Error MDA K-40 + 4.29E+03 + 3.50E+02 1.28E+02 MN-54 -8.62E-01 + 6.40E+00 1.03E+01 CO-58 -3.90E-01 + 3.35E+00 5.32E+00 FE-59 9.19E+00 + 1'86E+01 2.80E+01 CO-60 2.99E-01 + 8.97E+00 1.47E+01 ZN-65 6.05E+00 + 1.46E+01 2.24E+01 ZRNB-95 5.06E-02 + 5.83E+00 9.56E+00 1-131 0.OOE+00 + 4.87E+00 8.12E+00 CS-134 -1.04E-01 + 6.12E+00 1.OOE+01 CS-137 0.OOE+00 + 8.12E+00 1.35E+01 BALA140 -1.59E+00 + 7.72E+00 1.21 E+01 Station 9c Potato collected 9/23/2009 FNucIlide RQ Activity Error MD0-A--- I I I I I I I I I I I I I I I I I I I K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA 40 + 3.49E+03 + 0.OOE+00 + 1.54E+00 + -1.64E+00 + -1.50E+00 + -9.16E+00 + 6.49E-01 + 0.OOE+00 + -1.97E+00 + -4.67E-01 + -1.61 E-02 + 3.01 E+02 6.47E+00 5.91 E+00 1.82E+01 8.61 E+00 1.85E+01 5.94E+00 5.81 E+00 6.30E+00 6.43E+00 5.56E+00 1.07E+02 1.08E+01 9.34E+00 2.95E+01 1.38E+01 2.86E+01 9.61 E+00 9.69E+00 9.99E+00 1.05E+01 9.14E+00 Station 37 Potato collected 9/23/2009 FNiuclide RQ Activity Error MDA 7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA140 + 4.20E+03 + 1.51 E-02 + -1.32E+00 + -9.93E-02 + 1.58E+00 + 1.21 E+01 + 0.OOE+00 + 1.57E+00 + -2.49E-02 + 3.17E+00 + -3.17E-01 + 3.75E+02 7.96E+00 6.02E+00 2.24E+01 1.02E+01 1.93E+01 1.25E+01 5.92E+00 6.22E+00 8.26E+00 7.64E+00 1.21 E+02 1.31 E+01 9.47E+00 3.69E+01 1.64E+01 2.87E+01 2.08E+01 9.38E+00 1.02E+01 1.29E+01 1.24E+01 M C F C z ZRN CA C5 BAL K-40 + 4.58E+03 + lN-54 -2.28E+00 + 0-58 3.82E+00 + E-59 8.26E-01 + 0-60 1.46E-01 + _N-65 -9.30E+00 + JB-95 1.85E+00 + 1-131 1.19E-01 + 3-134 2.98E+00 + 3-137 3.40E+00 + _A140 2.84E+00 + 4.06E+02 9.28E+00 7.66E+00 2.32E+01 1.10E+01 2.20E+01 7.49E+00 6.40E+00 6.16E+00 8.59E+00 9.45E+00 1.47E+02 1.48E+01 1.16E+01 3.79E+01 1.80E+01 3.40E+01 1.18E+01 1.05E+01 9.34E+00 1.33E+01 1.44E+01 Page 1 of 1 RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit.

TABLE A-1 5.2 GAMMA SPECTROMETRY RESULTS OF ROOTS-

SUMMARY

Results in pCi/ kilogram (wet) Nuclide BALA1 40 BALA 40 CO-58 CO-58 CO-60 CO-60 CS-1 34 CS-1 34 CS-1 37 CS-1 37 FE-59 FE-59 1-131 1-131 K-40 K-40 MN-54 MN-54 ZN-65 ZN-65 ZRNB-95 ZRNB-95 Ind CntI Ind CntI Ind Cntl Ind Cntl Ind CntI Ind Cnti Ind Cnti Ind CntI Ind CntI Ind CntI Ind Cnti Average Activity -4.26E-02 -2.89E-01 -1.14E-01 4.17E-01 1.54E+00 4.95E-01 -3.45E-01 8.07E-01 2.79E-01 6.52E-01 -7.09E-01 -4.31 E-01 1.50E+00 4.56E-01 3.34E+03 3.49E+03 8.01 E-02 -1.08E+00 -8.23E-01 -1.82E+00 1.50E-01 -7.12E-02 Activity Activity Low High -7.05E-01 8.68E-01 -2.40E+00 2.84E+00 -1.32E+00 1.54E+00 -1.75E+00 3.82E+00 -1.50E+00 4.29E+00 -8.85E-01 2.42E+00 -1.97E+00 7.42E-01 -1.04E-01 2.98E+00 -1.55E+00 3.17E+00 -8.32E-01 3.40E+00 -3.1 OE+00 2.01 E+00 -6.34E+00 9.19E+00 0.OOE+00 3.32E+00 0.OOE+00 1.69E+00 1.75E+03 4.20E+03 1.14E+03 4.58E+03 -7.42E-01 1.05E+00 -2.28E+00 0.OOE+00 -9.16E+00 1.21 E+01 -9.30E+00 6.05E+00 -1.95E-01 6.49E-01 -2.94E+00 1.85E+00 Average Number of MDA Samples 1.01 E+01 4 1.08E+01 4 8.63E+00 4 9.11E+00 4 1.36E+01 4 1.51 E+O1 4 8.59E+00 4 1.01 E+01 4 1.03E+01 4 1.17E+01 4 3.46E+01 4 3.26E+01 4 8.49E+00 4 8.72E+00 4 1.23E+02 4 1.31 E+02 4 1.03E+01 4 1.33E+01 4 2.59E+01 4 2.69E+01 4 1.23E+01 4 9.56E+00 4 Number of Positive IDs Ind = Indicator Station Cntl = Control Station Page 1 of 1

TABLE A-16.1 GAMMA SPECTROMETRY RESULTS OF FRUIT Results in pCi/ kilogram (wet) Station 37 Strawberries collected 6/17/2009 46Ncllide R--Q-Ac-tivity Error MDA Station 9c Strawberries collected 6/17/2009 FNu-clidle RQ Activity Error MDA7] K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA 40 + 1.43E+03 + 0.OOE+00 + -8.49E-01 + -1.28E-01 + 0.OOE+00 + 0.OOE+00 + 1.33E+00 + 2.53E+00 + 2.75E-01 + 1.47E+00 + 0.OOE+00 + 2.18E+02 1.44E+00 6.52E+00 1.79E+01 1.10E+01 2.34E+01 6.10E+00 5.17E+00 5.30E+00 5.42E+00 1.51 E+01 1.26E+02 2.40E+00 1.05E+01 2.94E+01 1.84E+01 3.91E+01 9.68E+00 7.94E+00 8.65E+00 8.44E+00 2.52E+01 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA 140 + 1.79E+03 + -2.68E-01 + 0.OOE+00 + 0.OOE+00 + 1.24E+00 + -1.62E+00 + 5.30E-01 + 3.86E+00 + 0.OOE+00 + 1.13E+00 + -4.51E-01 + 2.13E+02 4.86E+00 5.63E+00 2.21 E+01 6.94E+00 1.21 E+01 4.64E+00 4.07E+00 4.78E+00 5.25E+00 5.99E+00 1.02E+02 7.92E+00 9.38E+00 3.68E+01 1.11E+01 1.94E+01 7.48E+00 5.74E+00 7.96E+00 8.32E+00 9.67E+00 Station 37 Apricots collected 7/20/2009 FN liile-RQ Activity Error MDA ] Station 9c Apricots collected 7/20/2009 FNuclide RQ Activit-- Error MDA--- K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA 40 + 2.54E+03 + 0.OOE+00 + -2.40E+00 + 3.14E+00 + 0.OOE+00 + -5.78E+00 + 3.33E+00 + 3.18E+00 + -1.67E+00 + 1.05E+00 + -1.02E-01 + 2.87E+02 6.01 E+00 6.53E+00 1.88E+01 1.04E+01 1.87E+01 6.73E+00 4.92E+00 5.69E+00 6.47E+00 7.69E+00 1.57E+02 1.OOE+01 1.01E+01 3.OOE+01 1.73E+01 2.94E+01 1.03E+01 7.31 E+00 8.97E+00 1.04E+01 1.26E+01 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA 40 + 2.37E+03 -1.28E+00 6.65E-01 -4.34E+00 1.82E+00 -3.04E+00 1.14E+00 7.60E-01 8.88E-01 1.04E+00 0.OOE+00 + + + + + + + + + +_ + 2.57E+02 6.11 E+00 4.88E+00 1.99E+01 6.55E+00 1.48E+01 5.18E+00 4.81 E+00 5.11E+00 6.09E+00 2.31 E+00 1.21 E+02 9.73E+00 7.81 E+00 3.17E+01 1.02E+01 2.36E+01 8.19E+00 7.74E+00 8.19E+00 9.76E+00 3.85E+00 I I I I I I I I I I I I I I U I I I I Station 37 Peaches collected 8/17/2009 FNuclide RQ Activity Error MDA-- Station 9c Peaches collected 8/17/2009 FN-*lidiie RQ-A-ktility Error M D-A----] K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA140 + 1.33E+03 + -8.23E-03 + -1.58E+00 + 0.OOE+00 + 1.94E+00 + -4.85E+00 + 4.89E-01 + 0.OOE+00 + 4.25E-02 + 7.65E-01 + 0.OOE+00 + 1.91 E+02 5.06E+00 5.25E+00 1.98E+01 6.53E+00 1.55E+01 4.86E+00 3.65E+00 4.28E+00 5.11E+00 8.90E+00 1.23E+02 8.32E+00 8.20E+00 3.30E+01 1.02E+01 2.44E+01 7.85E+00 6.08E+00 7.03E+00 8.18E+00 1.48E+01 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 + 1.46E+03 + 3.97E-01 + 1.24E+00 + -3.58E+00 + 3.90E+00 + O.OOE+00 + 3.41 E+00 + -3.90E-01 + 3.51 E-01 + -4.92E-01 + 0.OOE+00 + 2.02E+02 4.76E+00 5.44E+00 1.82E+01 7.72E+00 2.04E+01 4.34E+00 4.83E+00 4.54E+00 5.31 E+00 1.35E+01 1.11E+02 7.69E+00 8.59E+00 2.89E+01 1.17E+01 3.40E+01 5.89E+00 7.86E+00 7.37E+00 8.59E+00 2.25E+01 Station 37 Peaches collected 9/23/2009 FNu-c-liie_ Ac-ivity Error MDA 1 K-40 + 2.08E+03 + 2.70E+02 1.45E+02 MN-54 -8.26E-01 + 6.98E+00 1.13E+01 CO-58 -5.19E-01 + 6.06E+00 9.81E+00 FE-59 0.OOE+00 + 2.56E+01 4.26E+01 CO-60 0.OOE+00 + 9.33E+00 1.55E+01 ZN-65 -2.49E+00 + 1.65E+01 2.64E+01 ZRNB-95 1.01 E+00 + 7.29E+00 1.18E+01 1-131 -1.44E+00 + 7.60E+00 1.23E+01 CS-134 -2.62E+00 + 7.04E+00 1.10E+01 CS-137 -1.68E+00 + 6.85E+00 1.08E+01 BALA140 5.71E-01 + 8.48E+00 1.37E+01 Station 9c Peaches collected 9/23/2009 FNu-clile-- -Ro A-ctiiitfy Error MDA ] K-40 + 1.54E+03 + 2.22E+02 1.12E+02 MN-54 2.09E+00 + 5.06E+00 7.57E+00 CO-58 0.OOE+00 + 1.47E+00 2.44E+00 FE-59 -8.42E-01 + 1.49E+01 2.42E+01 CO-60 1.42E+00 + 8.86E+00 1.42E+01 ZN-65 8.95E-02 + 9.60E+00 1.57E+01 ZRNB-95 -1.10E-01 + 5.74E+00 9.41E+00 1-131 6.75E-01 + 5.36E+00 8.66E+00 CS-134 8.79E-01 + 5.71E+00 9.17E+00 CS-1 37 2.15E-03 + 5.35E+00 8.77E+00 BALA140 0.OOE+00 + 2.70E+00 4.50E+00 RQ = Results Qualifier. It blank, result is less than detection limit. If "+", result is above detection limit. Page 1 of 2

TABLE A-16.1 GAMMA SPECTROMETRY RESULTS OF FRUIT Results in pCi/ kilogram (wet) Station 92 Apples collected 9/22/2009 FNu-clide RO Activity Error MDA--- K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 + 1.11E+03 + 7.54E+00 + 3.96E+00 + 6.72E+00 + 4.06E+00 + 0.OOE+00 + 1.04E+00 + 2.05E+00 + 1.77E+00 + 1.86E-02 + -2.01 E+00 + 2.10E+02 6.60E+00 6.68E+00 1.59E+01 5.97E+00 3.52E+01 5.47E+00 5.36E+00 4.52E+00 5.01 E+00 8.70E+00 1.80E+02 8.50E+00 9.83E+00 2.35E+01 8.04E+00 5.87E+01 8.65E+00 8.30E+00 6.84E+00 8.23E+00 1.35E+01 TABLE A - 16.2 GAMMA SPECTROMETRY RESULTS OF FRUIT-

SUMMARY

Results in pCi/ kilogram (wet) Average Activity Activity Activity Low High Average Number of Number of MDA Samples Positive IDs Nuclide BALA140 Ind -3.09E-01 BALA140 Cntl -1.13E-01 CO-58 Ind -2.78E-01 CO-58 Cntl 4.77E-01 CO-60 Ind 1.20E+00 CO-60 Cntl 2.09E+00 CS-1 34 Ind -4.42E-01 CS-1 34 Cntl 5.29E-01 CS-1 37 Ind 3.24E-01 CS-137 Cntl 4.19E-01 FE-59 Ind 1.95E+00 FE-59 Cntl -2.19E+00 1-131 Ind 1.26E+00 1-131 Cntl 1.23E+00 K-40 Ind 1.70E+03 K-40 Cntl 1.79E+03 MN-54 Ind 1.34E+00 MN-54 Cntl 2.35E-01 ZN-65 Ind -2.62E+00 ZN-65 Cntl -1.14E+00 ZRNB-95 Ind 1.44E+00 ZRNB-95 Cntl 1.24E+00 -2.01E+00 5.71E-01 1.60E+01 -4.51E-01 0.OOE+00 1.01 E+01 -2.40E+00 3.96E+00 9.69E+00 0.OOE+00 1.24E+00 7.06E+00 0.OOE+00 4.06E+00 1.39E+01 1.24E+00 3.90E+00 1.18E+01 -2.62E+00 1.77E+00 8.50E+00 0.OOE+00 8.88E-01 8.17E+00 -1.68E+00 1.47E+00 9.21 E+00 -4.92E-01 1.13E+00 8.86E+00 -1.28E-01 6.72E+00 3.17E+01 -4.34E+00 0.OOE+00 3.04E+01 -1.44E+00 3.18E+00 8.38E+00 -3.90E-01 3.86E+00 7.50E+00 1.11E+03 2.54E+03 1.46E+02 1.46E+03 2.37E+03 1.12E+02 -8.26E-01 7.54E+00 8.1OE+00 -1.28E+00 2.09E+00 8.23E+00 -5.78E+00 0.OOE+00 3.56E+01 -3.04E+00 8.95E-02 2.32E+01 4.89E-01 3.33E+00 9.64E+00 -1.10E-01 3.41 E+00 7.74E+00 Ind = Indicator stations CntrI = Control Stations RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 2 of 2

TABLE A-17.1 GAMMA SPECTROMETRY RESULTS OF VEGETABLES Results in pCi/ kilogram (wet) Station 37 Asparagus collected 4/20/2009 Nuclide RQ Activity Error IMDA---] Station 37 Cabbage collected 8/17/2009 [ Nuclide RQ Activity Error MDA K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 + 2.16E+03 + 4.40E+00 + 7.92E-02 + -4.02E+00 + 3.60E-02 + -4.37E+00 + -1.10E+00 + -9.12E-02 + -2.38E+00 + 0.OOE+00 + -4.86E-01 + 2.78E+02 6.85E+00 6.06E+00 2.42E+01 8.35E+00 1.81 E+01 7.33E+00 5.32E+00 6.96E+00 8.99E+00 6.40E+00 1.43E+02 9.92E+00 9.95E+00 3.88E+01 1.37E+01 2.85E+01 1.18E+01 8.73E+00 1.09E+01 1.50E+01 1.03E+01 M C F C 2 ZRN CSA CSI BALi K-40 + 2.53E+03 + IN-54 2.79E+00 +

0-58 4.14E+00 +

E-59 -1.82E-01 + 0-60 -2.44E+00 + N-65 -4.74E+00 + JB-95 9.01E-01 + 1-131 3.43E+00 + -134 2.90E-02 + -137 0.OOE+00 + A140 1.37E-01 + 2.95E+02 7.49E+00 6.88E+00 2.12E+01 1.10E+01 1.43E+01 4.50E+00 5.20E+00 6.22E+00 6.76E+00 6.42E+00 1.38E+02 1.1 6E+01 1.01 E+01 3.47E+01 1.75E+01 2.19E+01 7.02E+00 7.67E+00 1.02E+01 1.13E+01 1.05E+01 Station 37 Asparagus collected 5/15/2009 FNiuciide RQ Activity Error MDA K-40 + 2.28E+03 + 2.99E+02 1.65E+02 Station 37 Green Peppers collected 9/23/2009 -Nuclide RQ Activity Error MDA K-40 + 1.76E+03 + 2.59E+02 1.35E+02 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA1 40 -1.37E+00 + -1.31 E+00 + 0.OOE+00 + 2.48E+00 + -3.09E+00 + 3.89E+00 + -1.64E+00 + -1.47E+00 + -1.26E+00 + 0.OOE+00 + 8.13E+00 6.69E+00 5.97E+00 7.79E+00 1.75E+01 5.59E+00 8.05E+00 6.51 E+00 6.93E+00 3.60E+00 1.30E+01 1.06E+01 9.95E+00 1.19E+01 2.79E+01 7.63E+00 1.29E+01 1.03E+01 1.10E+01 6.OOE+00 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA1 40 0.OOE+00 + 4.62E-01 + -2.35E+00 + 1.27E+00 + -1.70E+00 + -2.55E+00 + 7.22E-01 + -1.16E+00 + 1.72E+00 + 0.OOE+00 + 5.07E+00 4.84E+00 2.04E+01 8.67E+00 1.83E+01 7.01 E+00 6.84E+00 6.78E+00 7.50E+00 1.38E+01 8.45E+00 7.76E+00 3.28E+01 1.39E+01 2.96E+01 1.08E+01 1.11 E+01 1.09E+01 1.18E+01 2.30E+01 I I I I I U I I I I I I I I I I I I I Station 37 Cabbage collected 6/17/2009 --Nuclde RQ Activity Error MDA Station 9c Asparagus collected 4/20/2009 7 Nuclide RQ Activity Error MDA K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-137 BALA1 40 + 1.77E+03 + 8.66E-01 + -4.30E-01 + 2.13E+00 + -3.41 E+00 + 4.56E+00 + 3.46E-01 + -1.65E-01 + 1.38E+00 + 2.25E+00 + -1.31 E+00 + 2.99E+02 9.68E+00 8.19E+00 3.02E+01 1.33E+01 1.92E+01 8.75E+00 8.91 E+00 7.52E+00 6.92E+00 1.38E+01 1.75E+02 1.57E+01 1.33E+01 4.90E+01 2.09E+01 3.OOE+01 1.43E+01 1.46E+01 1.20E+01 1.05E+01 2.22E+01 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA140 + 2.61E+03 -1.01 E+00 -1.26E+00 0.OOE+00 9.14E-01 3.24E+00 1.65E+00 1.39E+00 -1.27E+00 -2.76E+00 0.OOE+00 + + +- +- -+t 3.21 E+02 6.65E+00 7.78E+00 5.67E+00 9.55E+00 1.90E+01 6.66E+00 5.65E+00 6.81 E+00 6.97E+00 3.07E+00 1.70E+02 1.06E+01 1.25E+01 9.44E+00 1.54E+01 3.04E+01 1.05E+01 8.95E+00 1.09E+01 1.06E+01 5.11 E+00 Station 37 Cabbage collected 7/20/2009 -Nu-clide RO Activity Error MDA K-40 + 2.92E+03 + 3.21 E+02 1.42E+02 Station 9c Asparagus collected 5/18/2009 FNuclide RO Activity Error MDA K-40 + 2.96E+03 + 3.25E+02 1.44E+02 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA1 40 5.65E-01 + 8.37E-01 + -2.80E+00 + 1.38E+00 + 2.22E+00 + 9.66E-01 + -2.28E-01 + -1.14E+00 + -8.50E-04 + 0.OOE+00 + 5.65E+00 5.44E+00 2.49E+01 9.76E+00 1.73E+01 6.17E+00 6.38E+00 8.16E+00 6.64E+00 1.83E+01 9.08E+00 8.64E+00 4.02E+01 1.57E+01 2.78E+01 9.85E+00 1.04E+01 1.32E+01 1.10E+01 3.04E+01 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA1 40 1.21 E-01 7.67E-01 7.75E+00 1.94E+00 -5.02E-01 0.OOE+00 7.15E-01 -4.81 E-01 5.64E-01 4.31 E+00 +r +- +- +- +- +- +- +- +- +- 5.72E+00 6.90E+00 2.14E+01 7.90E+00 2.03E+01 7.06E+00 5.77E+00 5.74E+00 7.87E+00 8.07E+00 9.36E+00 1.11E+01 3.28E+01 1.23E+01 3.32E+01 1.18E+01 9.33E+00 9.31 E+00 1.28E+01 1.13E+01 Page 1 of 2 RQ = Results Qualifier. If blank, result is less than detection limit, If "+", result is above detection limit.

TABLE A-1 7.1 GAMMA SPECTROMETRY RESULTS OF VEGETABLES Results in pCi/ kilogram (wet) Station 9c Cabbage collected F[Nu-cide RO Activity Error K-40 + 1.81E+03 + 2.34E+02 6/17/2009 'MDA I Station 102g Broad Leaf Vegtable collected 7/27/2009 FINuclide RO Activity Error MDA K-40 + 4.86E+03 + 6.08E+02 2.99E+02 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-137 BALA 40 -1.79E-01 + -1.92E+00 + 0.OOE+00 + 2.99E+00 + -1.04E-02 + 0.OOE+00 + -1.08E-01 + 1.85E+00 + 1.18E+00 + 0.OOE+00 + 5.55E+00 6.36E+00 1.64E+01 6.89E+00 1.06E+01 5.94E+00 3.99E+00 4.82E+00 5.98E+00 2.46E+00 Station 9c Cabbage collected I Nuclide RQ Activity K-40 + 2.56E+03 + MN-54 -2.35E+00 + CO-58 -1.37E+00 + FE-59 1.03E+01 + CO-60 3.18E+00 + ZN-65 -1.84E+00 + ZRNB-95 -1.82E+00 + 1-131 3.29E-02 + CS-1 34 1.47E+00 + CS-137 2.49E+00 + BALA140 -2.72E+00 + Error 2.95E+02 8.15E+00 7.40E+00 1.55E+01 7.38E+00 1.70E+01 7.08E+00 5.86E+00 5.1 4E+00 6.89E+00 9.41 E+00 1.21E+02 9.08E+00 9.95E+00 2.73E+01 1.04E+01 1.74E+01 9.90E+00 6.52E+00 7.39E+00 9.51 E+00 4.1 OE+00 7/20/2009 MDA 1.37E+02 1.28E+01 1.18E+01 2.09E+01 1.10E+01 2.75E+01 1.12E+61 9.63E+00 8.02E+00 1.06E+01 1.44E+01 8/17/2009 MDA----7 1.46E+02 1.13E+01 1.10E+01 3.47E+01 1.45E+01 2.43E+01 1.20E+01 9.04E+00 1.06E+01 1.08E+01 1.44E+01 Station 102g Broad Leaf Vegtable collected 8/24/2009 I Nuclide RQ .Activity Error MDA ] K-40 + 3.84E+03 + 4.84E+02 2.60E+02 MN-54 -1.46E+00 + 1.19E+01 1.92E+01 CO-58 -2.90E+00 + 1.17E+01 1.85E+01 FE-59 3.49E-01 +/- 3.OOE+01 4.92E+01 CO-60 4.30E+00 + 1.45E+01 2.26E+01 ZN-65 -1.29E+01 + 3.67E+01 5.75E+01 ZRNB-95 1.77E-01 + 1.25E+01 2.05E+01 1-131 -9.50E-02 + 8.86E+00. 1.45E+01 CS-134 5.30E+00 + 8.17E+00 1,16E+01 CS-137 -2.71E-01 + 1.38E+01 2.26E+01 BALA140 -4.12E+00 +/- 1.72E+O1 2.68E+01 Station 102g Broad Leaf Vegtable collected 9/30/2009 F Nuclide RQ Activity Error MDA K-40 + 5.12E+03 + 6.23E+02 2.96E+02 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 -1.51 E+00 + -1.98E+00 + -7.54E-01 + 1.40E+01 + -8.62E+00 + 2.57E+00 + 6.05E+00 + 0.OOE+00 + 9.91 E-03 + -4.91 E+00 + 1.45E+01 1.50E+01 4.08E+01 2.06E+01 4.02E+01 1.55E+01 1.37E+01 1.34E+01 1.53E+01 1.87E+01 2.34E+01 2.42E+01 6.68E+01 3.02E+01 6.40E+01 2.48E+01 2.11E+01 2.24E+01 2.51 E+01 2.86E+01 Station 9c Cabbage collected FNWuclide RO Activity Error K-40 + 2.11E+03 + 2,78E+02 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-137 BALA 40 3.71E-01 + 0.OOE+00 + -4.66E+00 + 3.08E+00 + 7.86E-01 + -3.37E+00 + -7.23E-02 + -1.88E+00 + -8.33E-01 +/- -2.OOE+00 + 6.93E+00 6.62E+00 2.20E+01 9.37E+00 1.49E+01 7.80E+00 5.51 E+00 6.74E+00 6.70E+00 9.26E+00 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 140 0.OOE+00 1.70E-01 0.OOE+00 9.32E-02 1.14E+01 2.54E+00 3.80E+00 -3.70E+00 -5.70E+00 -1.95E+00 + + + + + + + 1.85E+01 1.61 E+01 4.16E+01 2.16E+01 .3.58E+01 1.29E+01 1.39E+01 1.24E+-01 1.70E+01 1.61 E+01 3.08E+01 2.64E+01 6.93E+01 3.55E+01 5.57E+01 2.05E+01 2:21 E+01 1.93E+01 2.65E+01 2.55E+01 Station 9c Green Peppers collected 9/23/2009 7 Nuclide RQ Activity Error MDA .1 Station 103A Broad Leaf Vegtable collected 9/30/2009 1 Nuclide RO Activity Error MIAx-- M C F C Z ZRN CSL CS11 BALI K-40 + 1.65E+03 + IN-54 -8.70E-01 + 0-58 0.OOE+00 + E-59 3.19E+00 + 0-60 2.50E+00 + N-65 -4.72E+00 + IB-95 -5.61E-01 + 1-131 -8.94E-01 + -134 -3.91 E+00 + S-137 4.39E-01 + A140 3.09E+00 + 2.63E+02 7.21 E+00 8.22E+00 2.13E+01 9.17E+00 2.1OE+01 7.59E+00 5.79E+00 9.19E+00 8.27E+00 5.46E+00 1.57E+02 1.16E+01 1.37E+01 3.40E+01 1.43E+01 3.33E+01 1.23E+0i 9.29E+00 1.44E+01 1.35E+01 6.39E+00 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA1 40 + 4.81E+03 6.98E+00 9.22E+00 -6.05E+00 7.47E+00 0.OOE+00 3.54E+00 -4.62E+00 5.02E+00 0.OOE+00 1.20E+01 + + + +{ + 4+/- + + + + 6.84E+02 1.84E+01 1.43E+01 5.61 E+01 2.42E+01 4.97E+01 1.54E+01 1.87E+01 1.47E+01 2.21 E+01 2.89E+01 3.70E+02 2.82E+01 2.OOE+01 9.05E+01 3.77E+01 8.28E+01 2.42E+01 2.99E+01 2.27E+01 3.68E+01 4.35E+01 Page 2 of 2 RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit.

TABLE A-17.2 GAMMA SPECTROMETRY RESULTS OF VEGETABLES-

SUMMARY

Results in pCi/ kilogram (wet) Nuclide BALA 40 BALA 40 CO-58 CO-58 CO-60 CO-60 CS-1 34 CS-1 34 CS-1 37 CS-1 37 FE-59 FE-59 1-131 1-131 K-40 K-40 MN-54 MN-54 ZN-65 ZN-65 ZRNB-95 ZRNB-95 Ind Cntl Ind Cntl Ind Cntl Ind Cntl Ind Cntl Ind Cntl Ind Cntl Ind Cntl Ind Cntl Ind Cntl Ind Cntl Average Activity -6.03E-02 4.48E-01 8.29E-01 -6.32E-01 2.52E+00 2.43E+00 1.89E-01 -7.04E-01 -3.26E-01 1.80E-01 -1.37E+00 2.76E+00 7.16E-01 1.77E-01 3.20E+03 2.28E+03 1.1 3E+00 -6.53E-01 -1.73E+00 -5.09E-01 1.13E+00 -6.82E-01 Activity Low -4.91 E+00 -2.72E+00 -2.90E+00 -1.92E+00 -3.41 E+00 9.14E-01 -3.70E+00 -3.91 E+00 -5.70E+00 -2.76E+00 -6.05E+00 -4.66E+00 -4.62E+00 -8.94E-01 1.76E+03 1.65E+03 -1.51 E+00 -2.35E+00 -1.29E+01 -4.72E+00 -2.55E+00 -3.37E+00 Activity. High 1.20E+01 4.31 E+00 9.22E+00 7.67E-01 1.40E+01 3.18E+00 5.30E+00 1.85E+00 2.25E+00 2.49E+00 2.13E+00 1.03E+01 6.05E+00 1.39E+00 5.12E+03 2.96E+03 6.98E+00 3.71 E-01 1.14E+01 3.24E+00 3.89E+00 1.65E+00 Average Number of MDA Samples 2.27E+01 10 9.29E+00 6 1.49E+01 10 1.17E+01 6 2.20E+01 10 1.30E+01 6 1.43E+01 10 1.01E+01 6 1.82E+01 10 1.13E+01 6 4.81E+01 10 2.65E+01 6 1.53E+01 10 8.79E+00 6 2.12E+02 10 1.46E+02 6 1.69E+01 10 1.08E+01 6 4.26E+01 10 2.77E+01 6 1.51 E+01 10 1.13E+01 6 Number of Positive IDs I I I I I I U I Ind = Indicator Stations Cntl = Control Stations Page 1 of 1

TABLE B-1.1 2009 QUARTERLY & ANNUAL SPECIAL INTEREST TLD RESULTS Results in milli-Roentgen (mR) Quarterly Sum Ratio Quarterly Annual Sum / Annual Station ID 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter 58 87 88 89 90 119B 119C 120 (East) 121 122 123 124 125 126 127 128 129 136A 137A 138A 150 (Site 1) 151 (Site 4) NA 26.85 30.68 29.38 18.65 21.16 22.06 21.34 97.13 40.32 154.80 181.62 128.56 137.51 96.76 177.42 131.18 199.12 224.98 181.04 19.63 19.36 19.20 22.78 24.53 23.22 18.37 22.16 20.87 21.96 49.51 38.80 141.66 178.29 122.14 124.77 89.23 157.10 119.39 186.51 205.23 159.90 18.05 18.98 18.52 25.13 25.67 24.64 18.54 20.73 21.60 21.77 62.07 37.93 144.40 170.02 120.62 126.92 89.38 160.73 120.71 183.87 205.17 163.54 19.21 19.58 19.93 32.67 29.54 27.04 19.50 23.70 22.40 23.52 86.63 40.66 139.93 175.47 124.56 123.44 90.68 156.13 120.94 180.18 197.33 158.70 19.19 19.87 NA 107.4 110.4 104.3 75.1 87.8 86.9 88.6 295.3 157.7 580.8 705.4 495.9 512.6 366.1 651.4 492.2 749.7 832.7 663.2 76.1 77.8 NA 107.2 109.7 112.7 77.3 81.1 85.2 83.4 297.9 161.4 593.2 692.5 498.6 524.9 373.8 667.7 481.0 763.7 865.2 688.0 72.0 73.3 NA 1.00 1.01 0.93 0.97 1.08 1.02 1.06 0.99 0.98 0.98 1.02 0.99 0.98 0.98 0.98 1.02 0.98 0.96 0.96 1.06 1.06 TABLE B-1.2 2009 QUARTERLY & ANNUAL SPECIAL INTEREST TLD RESULTS-

SUMMARY

Results in milli-Roentgen (mR) Average Activity Activity Low Activity Number of Number of High Samples Positive IDs Location ST 119 Quarterly Ind ST 119 Quarterly Cntl ST 120 Quarterly Ind ISFSI Quarterly Ind ISFSI Annual Ind SITE 1 & 4 Quarterly Ind 21.9 21.7 22.1 135.5 550.7 19.2 20.7 20.9 21.3 37.9 161.4 18.0 23.7 22.4 23.5 225.0 865.2 19.9 4 4 4 48 12 8 4 4 4 48 12 8 1st Q 12/30/08 to 3/31/09 - 2nd Q 3/31/09 to 6/25/09 - 3rd 0 6/25/09 to 9/25/09 - 4th Q 9/25/09 to 12/29/09 Ind = Indicator Station Cntl = Control Station Stations 121 through 138A are TLD locations associated with ISFSI Stations 58 and 87 to 90 were established in 2009 to monitor exposure from remediation work at the DOE 618-11 burial site. Page 1 of 1

Table B-2.1 GAMMA SPECTROMETRY RESULTS OF STORM DRAIN WATER STATION 101 Results in pCi/liter, corrected for decay during collection period Location 101 collected 2/2/2009 [ Nuclide RQ Activity Error MDA7] K-40 -3.47E+01 + 5.85E+01 5.26E+01 CR-51 -1.14E+01 + 1.94E+01 3.09E+01 MN-54 -7.32E-01 + 1.89E+00 3.01 E+00 CO-58 -1.30E-03 + 1.79E+00 2.93E+00 FE-59 2.04E-02 + 4.66E+00 7.66E+00 CO-60 1.18E+00 + 1.64E+00 2.46E+00 ZN-65 -3.26E-01 + 3.73E+00 6.09E+00 ZRNB-95 6.90E-02 + 2.05E+00 3.35E+00 1-131 -1.51 E+00 + 4.07E+00 6.53E+00 CS-134 -4.85E-01 + 1.50E+00 2.41E+00 CS-137 6.62E-01 + 1.55E+00 2.45E+00 BALA140 2.03E+00 + 3.85E+00 5.89E+00 BI-214 4.45E+00 + 4.OOE+00 7.19E+00 RA-226 -4.50E+00 + 4.04E+01 6.81 E+01 Location 101 collected 4/6/2009 F Nuclide RQ Activity Error MDA 7 K-40 -3.87E+01 + 6.12E+01 5.09E+01 CR-51 0.OOE+00 + 2.OOE+01 3.33E+01 MN-54 5.17E-01 + 1.71E+00 2.73E+00 CO-58 3.51 E-01 + 1.76E+00 2.84E+00 FE-59 -1.15E+00 + 5.53E+00 8.89E+00 CO-60 -1.90E-01 + 1.46E+00 2.35E+00 ZN-65 -1.22E+00 + 4.OOE+00 6.38E+00 ZRNB-95 -8.52E-01 + 2.24E+00 3.57E+00 1-131 9.99E-02 + 5.05E+00 8.29E+00 CS-1 34 1.18E+00 + 1.81E+00 2.85E+00 CS-1 37 6.45E-01 + 1.90E+00 3.04E+00 BALA140 0.OOE+00 + 4.73E+00 7.89E+00 BI-214 3.28E+00 + 4.68E+00 8.31 E+00 RA-226 1.14E+01 + 3.81E+01 6.86E+01 Location 101 collected 3/2/2009 [Nuclide RO Activity Error MD0A K-40 -2.07E+01 + 3.89E+01 5.07E+01 CR-51 -8.55E-01 + 1.83E+01 3.01E+01 MN-54 -5.06E-02 + 1.69E+00 2.78E+00 CO-58 1.10E+00 + 1.65E+00 2.53E+00 FE-59 2.16E+00 + 4.63E+00 7.16E+00 CO-60 -1.92E-01 + 1.86E+00 3.03E+00 ZN-65 8.16E-02 + 2.78E+00 4.54E+00 ZRNB-95 -9.75E-02 + 1.82E+00 2.98E+00 1-131 1.43E+00 + 3.28E+00 5.20E+00 CS-134 2.94E-01 + 2.03E+00 3.31E+00 CS-137 -1.02E+00 + 2.11E+00 3.35E+00 BALA140 1.89E-02 + 3.85E+00 6.31E+00 BI-214 4.41 E+00 + 4.86E+00 8.51 E+00 RA-226 -2.31E+01 + 6.07E+01 7.19E+01 Location 101 collected 5/6/2009 [KNuclide Rd Aciviity Error MDA I K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA140 BI-214 RA-226 -3.36E+01 + -3.11E-01 + -4.26E-01 + 5.05E-01 + 0.OOE+00 + 0.OOE+00 + -1.62E+00 + 5.85E-01 + -1.15E+00 + 6.52E-01 + 7.69E-01 + -1.22E+00 + -1.71 E+00 + 1.05E+01 + 4.98E+01 1.70E+01 1.98E+00 1.71 E+00 5.52E+00 1.16E+00 4.67E+00 2.01 E+00 5.11E+00 1.67E+00 1.70E+00 4.06E+00 6.15E+00 3.65E+01 4.92E+01 2.79E+01 3.20E+00 2.74E+00 9.20E+00 1.93E+00 7.46E+00 3.22E+00 8.30E+00 2.68E+00 2.68E+00 6.43E+00 8.40E+00 6.63E+01 7/1/2009 MDA I I I I I I I I I I I I I I U I I I I B Location 101 collected 6/1/2009 MDA i Location 101 collected F[Nuclide RO Activity Error [ Nuclide RQ Activity Error K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA140 BI-214 RA-226 -2.62E+01 + 7.67E-02 + -5.22E-01 + -5.26E-01 + -3.93E-01 + 1.68E+00 + -3.27E-02 + 1.43E-01 + -8.03E-01 + 9.64E-02 + 9.26E-01 + -1.24E-02 + 2.12E-01 + -4.06E+00 + 4.43E+01 1.31 E+01 1.85E+00 2.16E+00 4.36E+00 2.26E+00 2.45E+00 1.83E+00 4.71 E+00 2.07E+00 1.72E+00 3.86E+00 4.72E+00 4.36E+01 5.08E+01 2.15E+01 2.96E+00 3.49E+00 7.08E+00 3.48E+00 4.03E+00 2.98E+00 7.67E+00 3.40E+00 2.70E+00 6.35E+00 8.62E+00 7.29E+01 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA140 BI-214 RA-226 -5.48E+00 + -2.59E-01 + -4.36E-01 + 6.83E-02 + -1.34E+00 + 0.OOE+00 + -1.30E+00 + 5.31 E-01 + 2.13E+00 + 9.90E-01 + 8.32E-01 + 7.35E-01 + -1.26E+00 + 1.47E+01 + 3.05E+01 2.07E+01 1.96E+00 1.91 E+00 5.90E+00 1.87E+00 3.84E+00 2.15E+00 4.57E+00 1.78E+00 1.89E+00 4.27E+00 5.35E+00 4.17E+01 5.37E+01 3.40E+01 3.18E+00 3.12E+00 9.48E+00 3.11E+00 6.1OE+00 3.47E+00 7.30E+00 2.81 E+00 3.OOE+00 6.87E+00 8.03E+00 7.39E+01 RO = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 1 of 3

Table B-2.1 GAMMA SPECTROMETRY RESULTS OF STORM DRAIN WATER STATION 101 Results in pCi/liter, corrected for decay during collection period Location 101 collected 7/9/2009 FNu-cli-di RQ Activity Error MDA 7 K-40 -4.77E+01 + 1.29E+02 7.41 E+01 CR-51 -7.50E+00 + 3.04E+01 4.93E+01 MN-54 -6.74E-01 + 2.74E+00 4.38E+00 CO-58 1.16E+00 + 2.89E+00 4.54E+00 FE-59 2.79E+00 + 5.73E+00 8.56E+00 CO-60 -2.07E-01 + 2.60E+00 4.23E+00 ZN-65 -8.18E-01 + 6.04E+00 9.78E+00 ZRNB-95 2.31 E-02 + 2.82E+00 4.63E+00 1-131 2.46E+00 + 6.84E+00 1.10E+01 CS-134 1.72E+00 + 2.33E+00 3.55E+00 CS-1 37 -1.1 5E+00 + 3.14E+00 4.99E+00 BALA140 5.33E-01 + 5.78E+00 9.38E+00 BI-214 2.23E+00 + 6.11E+00 1.12E+01 RA-226 6.43E+01 + 7.54E+01 1.30E+02 Location 101 collected 7/13/2009 [ Nuclide RO Activity Error MDA 1 Location 101 collected RQ Activity Error Nuclide K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 RA-226 -4.98E+01 + 2.52E+01 + 4.35E-01 + 1.03E+00 + 4.OOE-01 + 0.OOE+00 + 7.67E-01 + -2.38E-01 + -2.95E+00 + 3.84E-02 + 1.71 E+00 + -1.69E+00 + -6.54E-01 + -9.03E+00 + 1.42E+02 3.07E+01 2.61 E+00 2.92E+00 8.37E+00 3.25E+00 5.60E+00 3.16E+00 7.31 E+00 2.08E+00 2.80E+00 6.72E+00 6.62E+00 8.32E+01 8/3/2009 MDA ] 7.48E+01 4.80E+01 4.21 E+00 4.63E+00 1.37E+01 5.42E+00 9.05E+00 5.16E+00 1.17E+01 3.42E+00 4.33E+00 1.07E+01 1.12E+01 1.32E+02 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA140 BI-214 RA-226 [ Nuclide K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA140 BI-214 RA-226 Location 101 collected 8/31/2009 RO Activity Error MDA -3.44E+01 + 7.32E+00 + 0.OOE+00 + 1.65E+00 + -1.40E+00 + 6.21 E-01 + 1.15E-01 + 1.57E-01 + 2.15E+00 + 0.OOE+00 + -1.09E-01 + 1.48E-03 + 8.24E+00 + 1.33E+01 + 8.17E+01 2.07E+01 3.24E+00 2.66E+00 7.12E+00 2.25E+00 5.50E+00 2.61 E+00 2.88E+00 3.12E+00 2.66E+00 3.05E+00 7.35E+00 5.94E+01 7.56E+01 3.30E+01 5.40E+00 4.03E+00 1.13E+01 3.51 E+00 9.01 E+00 4.26E+00 4.37E+00 5.20E+00 4.36E+00 5.03E+00 1.24E+01 1.06E+02 -4.10E+01 + 9.88E+00 + -1.46E-01 + 7.41E-01 + -3.71 E+00 + 1.60E+00 + 6.64E-01 + 1.22E+00 + 5.OOE+00 + 2.52E-02 + 1.61 E+00 + -7.25E-01 + 1.31 E+00 + -1.15E+01 + 6.60E+01 1.88E+01 1.88E+00 1.74E+00 6.11 E+00 2.02E+00 2.30E+00 2.05E+00 3.92E+00 1.65E+00 1.75E+00 4.25E+00 4.1 OE+00 4.79E+01 5.11E+01 3.OOE+01 3.07E+00 2.75E+00 9.46E+00 3.07E+00 3.60E+00 3.20E+00 5.88E+00 2.72E+00 2.65E+00 6.85E+00 7.62E+00 7.06E+01 Location 101 collected 10/5/2009 [FNIucide R0 Activity Error MDA Location 101 collected 11/2/2009 7 Nuclide RO Activity Error MDA 1 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 RA-226 -2.77E+01 + -1.37E+00 + 1.04E+00 + -7.70E-01 + 2.22E+00 + 2.03E+00 + 5.27E-02 + 5.31E-01 + 1.02E+00 + -8.45E-01 + -3.72E-01 + -1.99E+00 + -1.02E+00 + 8.45E+00 + 4.82E+01 2.10 E+01 1.67E+00 2.07E+00 5.58E+00 1.82E+00 4.28E+00 1.66E+00 5.95E+00 2.03E+00 1.81 E+00 5.60E+00 5.46E+00 4.32E+01 5.21 E+01 3.43E+01 2.58E+00 3.30E+00 8.77E+00 2.62E+00 7.03E+00 2.64E+00 9.69E+00 3.26E+00 2.93E+00 8.85E+00 8.42E+00 7.65E+01 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA 140 BI-214 RA-226 -3.12E+01 + 2.78E+00 + 8.OOE-02 + 6.89E-01 + 3.35E-01 + 1.61 E+00 + -3.12E+00 + 6.12E-01 + 2.47E+00 + 8.31 E-02 + 1.26E-01 + 5.53E-02 + + 1.60E+01 + -5.12E+00 + 4.99E+01 1.62E+01 1.61 E+00 1.78E+00 4.57E+00 1.72E+00 5.29E+00 1.78E+00 5.1 OE+00 1.89E+00 1.81 E+00 3.79E+00 5.82E+00 4.67E+01 5.07E+01 2.63E+01 2.64E+00 2.82E+00 7.44E+00 2.52E+00 8.33E+00 2.83E+00 8.17E+00 3.09E+00 2.96E+00 6.22E+00 8.12E+00 7.61 E+01 RQ = Results Qualifier. If blank, result is less than detection limit, If "+", result is above detection limit. Page 2 of 3

II Table B-2.1 GAMMA SPECTROMETRY RESULTS OF STORM DRAIN WATER STATION 101 Results in pCi/liter, corrected for decay during collection period Location 101 collected 11/30/2009 FINuclide RO Activity Error MIDA Location 101 collected 1/4/2010 I K-Nucliale RQ Activity Error IMDA 1 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 RA-226 -1.57E+01 + -7.08E+00 + 5.05E-01 + -1.24E+00 + 2.51 E+00 + -1.77E-01 + -2.40E+00 + 2.09E+00 + -2.1OE+00 + -1.13E+00 + -2.40E-01 + 6.95E-01 + 4.43E+00 + 1.51 E+01 + 4.05E+01 2.26E+01 1.70E+00 2.15E+00 5.48E+00 1.91 E+00 5.26E+00 1.92E+00 5.54E+00 2.24E+00 1.70E+00 4.55E+00 4.88E+00 4.74E+01 5.19E+01 3.65E+01 2.70E+00 3.36E+00 8.49E+00 3.11E+00 8.33E+00 2.80E+00 8.88E+00 3.56E+00 2.75E+00 7.32E+00 8.88E+00 8.65E+01 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA140 BI-214 RA-226 -2.01 E+01 + 1.23E+01 + -7.37E-01 + 8.61 E-01 + 1.98E+00 + 9.85E-01 + -8.87E-01 + 2.85E+00 + -4.82E-01 + -1.78E-01 + -1.03E+00 + 7.53E-01 + 8.07E+00 + 7.92E+00 + 4.07E+01 2.52E+01 2.15E+00 2.1OE+00 6.63E+00 1.99E+00 2.34E+00 2.16E+00 6.12E+00 2.42E+00 2.35E+00 4.97E+00 5.62E+00 4.96E+01 4.84E+01 4.03E+01 3.43E+00 3.32E+00 1.06E+01 3.09E+00 3.58E+00 3.1 OE+00 1.OOE+01 3.97E+00 3.75E+00 8.OOE+00 9.69E+00 9.02E+01 I I I I TABLE B-2.2 GAMMA SPECTROMETRY RESULTS OF STORM DRAIN WATER -

SUMMARY

STATION 101 Results in pCi/liter, corrected for decay during collection period Average Activity Activity Activity Low High Number of Average Number of Positive MDA Samples IDs Nuclide K-40 -3.05E+01 -4.98E+01 -5.48E+00 5.62E+01 14 CR-51 2.06E+00 -1.14E+01 2.52E+01 3.40E+01 14 MN-54 -8.20E-02 -7.37E-01 1.04E+00 3.31E+00 14 CO-58 4.01E-01 -1.24E+00 1.65E+00 3.31E+00 14 FE-59 3.16E-01 -3.71E+00 2.79E+00 9.13E+00 14 CO-60 6.39E-01 -2.07E-0t 2.03E+00 3.14E+00 14 ZN-65 -7.17E-01 -3.12E+00 7.67E-01 6.66E+00 14 ZRNB-95 5.45E-01 -8.52E-01 2.85E+00 3.44E+00 14 1-131 5.56E-01 -2.95E+00 5.OOE+00 8.07E+00 14 CS-134 1.75E-01 -1.13E+00 1.72E+00 3.30E+00 14 CS-137 2.39E-01 -1.15E+00 1.71 E+00 3.28E+00 14 BALA140 -5.79E-02 -1.99E+00 2.03E+00 7.29E+00 14 BI-214 3.43E+00 -1.71 E+00 1.60E+01 9.04E+00 14 RA-226 6.31E+00 -2.31E+01 6.43E+01 8.50E+01 14 RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. 0 0 0 0 0 0 0 0 0 0 0 0 1 0 I I I I I I I I I I Page 3 of 3

Table B-3.1 GROSS BETA IN STORM DRAIN WATER Results in pCi per liter Location Collection Period RO Activity Error MDA St 101 01/05/09 02/02/09 03/02/09 04/06/09 05/04/09 06/02/09 07/01/09 08/03/09 08/31/09 10/05/09 11/02/09 11/30/09 02/02/09 03/02/09 04/06/09 05/06/09 06/01/09 07/01/09 08/03/09 08/31/09 10/05/09 11/02/09 11/30/09 01/04/10 1.09E+00 1.72E+00 2.22E+00 4.73E-01 1.46E+00 2.07E+00 5.44E-01 7.1 OE-01 2.09E+00 1.72E+00 -4.87E-01 + 4.40E+00 +- + _.+ _+ + + +- +- +¢ 8.50E-01 1.02E+00 8.33E-01 7.03E-01 9.33E-01 7.77E-01 7.89E-01 7.83E-01 8.15E-01 7.87E-01 8.29E-01 8.55E-01 2.58E+00 3.26E+00 2.41 E+00 2.39E+00 2.76E+00 2.23E+00 2.59E+00 2.33E+00 2.32E+00 2.29E+00 2.64E+00 2.03E+00 TABLE B-3.2 GROSS BETA IN STORM DRAIN WATER -

SUMMARY

Results in pCi per liter Average Activity Activity Number of Number of Activity Low High Samples Positive IDs 1.50E+00 -4.87E-01 4.40E+00 12 1 Table B-4.1 TRITIUM IN STORM DRAIN WATER Results in pCi per liter Location Collection Period RQ Activity Error St 101 01/05/09 - 02/02/09 + 7.21E+03 + 2.19E+02 02/02/09 - 03/02/09 + 5.03E+03 + 1.90E+02 03/02/09 - 04/06/09 + 1.73E+03 _+ 1.37E+02 04/06/09 - 05/06/09 + 3.58E+02 + 9.88E+01 05/04/09 - 06/01/09 1.89E+02 + 9.68E+01 06/02/09 - 07/01/09 1.83E+02 + 9.64E+01 07/01/09 - 08/03/09 1.01 E+02 + 9.37E+01 08/03/09 - 08/31/09 4.39E+01 + 9.79E+01 08/31/09 - 10/05/09 2.32E+02 + 9.72E+01 10/05/09 - 11/02/09 2.95E+02 + 1.06E+02 11/02/09 - 11/30/09 + 5.02E+02 + 1.06E+02 11/30/09 - 01/04/10 + 5.08E+02 + 1.09E+02 TABLE B-4.2 TRITIUM IN STORM DRAIN WATER -

SUMMARY

Results in pCi per liter Average Activity Activity Number of Number of Activity Low High Samples Positive IDs 1.37E+03 4.39E+01 7.21 E+03 12 6 ST-101 tritium value for 7/1 to 8/3 is average of 4 analyses. All 4 Analyses were < MDA. RQ = Results Qualifier. If blank, result is less than detection Iomit. If "+", result is above detection limit. Page 1 of 1

Table B-5.1 GROSS ALPHA IN SANITARY WASTE TREATMENT WATER Results in pCi per liter ST 102A ST 102B RQ Activity Error Collection Period RQ Activity Error MDA MDA 01/05/09 02/02/09 03/02/09 04/06/09 05/04/09 06/02/09 07/01/09 08/03/09 08/31/09 10/05/09 11/02/09 11/30/09 02/02/09 03/02/09 04/06/09 05/06/09 06/01/09 07/01/09 08/03/09 08/31/09 10/05/09 11/02/09 11/30/09 01/04/10 2.90E+00 2.03E+00 6.08E-01 1.35E-01 -1.62E-01 -2.76E-01 3.79E-01 -3.85E-01 -4.76E-01 1.08E+00 -1.71E-16 -5.79E-01 + + + + 1.26E+00 1.07E+00 4.83E-01 3.44E-01 5.48E-01 5.44E-01 4.49E-01 7.1 OE-01 5.73E-01 6.21E-01 6.49E-01 6.96E-01 3.60E+00 3.34E+00 1.68E+00 1.60E+00 2.41 E+00 2.23E+00 1.80E+00 2.81 E+00 2.19E+00 1.94E+00 2.75E+00 2.59E+00 6.56E-01 -3.55E-01 7.96E-01 1.41 E+00 -8.88E-01 -7.20E-01 1.02E+00 -1.09E+00 4.76E-01 3.18E-01 -1.08E+00 -5.32E-01 + + + +r 1.06E+00 9.82E-01 6.33E-01 9.31 E-01 1.32E+00 8.67E-01 6.73E-01 1.01 E+00 7.68E-01 6.63E-01 1.01 E+00 9.21 E-01 4.23E+00 4.08E+00 2.21 E+00 3.03E+00 5.30E+00 3.32E+00 2.19E+00 3.62E+00 3.07E+00 2.87E+00 3.64E+00 3.56E+00 TABLE B-5.2 GROSS ALPHA IN SANITARY WASTE TREATMENT WATER -

SUMMARY

Results in pCi per liter Average Activity Activity Activity Low High Number Number of of Positive Samples IDs Location ST 102A ST 102B 4.38E-01 -5.79E-01 2.90E+00 1.07E-04 -1.09E+00 1.41E+00 12 12 0 0 Table B-6.1 GROSS BETA IN SANITARY WASTE TREATMENT WATER Results in pCi per liter I I I I I I I I I I I I I I I I I I I ST 10 RO Activity 2A Error MDA ST 102B Collection Period RO Activity Error MDA 01/05/09 02/02/09 03/02/09 04/06/09 05/04/09 06/02/09 07/01/09 08/03/09 08/31/09 10/05/09 11/02/09 11/30/09 02/02/09 03/02/09 04/06/09 05/06/09 06/01/09 07/01/09 08/03/09 08/31/09 10/05/09 11/02/09 11/30/09 01/04/10 + + + + + + + + + + + + 1.34E+01 1.28E+01 5.52E+00 5.50E+00 7.87E+00 5.58E+00 6.82E+00 5.32E+00 3.44E+00 7.30E+00 6.OOE+00 5.43E+00 + +¢ + -+ +_ + 1.40E+00 1.39E+00 9.85E-01 9.69E-01 1.17E+00 9.54E-01 1.08E+00 9.60E-01 8.60E-01 1.06E+00 1.06E+00 9.01E-01 2.78E+00 2.91 E+00 2.43E+00 2.42E+00 2.84E+00 2.31 E+00 2.65E+00 2.37E+00 2.37E+00 2.37E+00 2.69E+00 2.04E+00 + + + + 4. + + + + + + + 2.54E+01 2.47E+01 1.85E+01 1.85E+01 2.07E+01 1.36E+01 1.04E+01 1.10E+01 1.27E+01 1.02E+01 1.46E+01 1.60E+01 + + + + +r + +} + 1.78E+00 1.77E+00 1.52E+00 1.55E+00 1.70E+00 1.33E+00 1.25E+00 1.24E+00 1.30E+00 1.21 E+00 1.42E+00 1.37E+00 2.84E+00 2.98E+00 2.52E+00 2.63E+00 3.13E+00 2.43E+00 2.72E+00 2.45E+00 2.49E+00 2.49E+00 2.80E+00 2.13E+00 TABLE B-6.2 GROSS BETA IN SANITARY WASTE TREATMENT WATER -

SUMMARY

Results in pCi per liter Average Activity Activity Activity Low High Number Number of of Positive Samples IDs Location ST 102A ST 102B 7.08E+00 3.44E+00 1.34E+01 1.64E+01 1.02E+01 2.54E+01 12 12 12 12 RQ = Results Qualifier. If blank, result is less than detection limit. If "+, result is above detection limit. Page 1 of 1

TABLE B-7.1 GAMMA SPECTROMETRY RESULTS OF SANITARY WASTE TREATMENT WATER STATION 102A Results in pCi/liter, corrected for decay during collection period Location 102a collected 2/2/2009 Nu--ii-de RO Activity Error MD-A-K-40 -1.28E+01 + 3.03E+01 4.85E+01 CR-51 3.24E-01 + 1.68E+01 2.75E+01 MN-54 -7.72E-02 + 1.34E+00 2.18E+00 CO-58 2.57E-01 + 1.88E+00 3.06E+00 FE-59 -2.27E+00 + 5.42E+00 8.50E+00 CO-60 -4.15E-01 + 1.62E+00 2.59E+00 ZN-65 1.20E+00 + 2.78E+00 4.31 E+00 ZRNB-95 8.91E-01 + 1.86E+00 2.93E+00 1-131 -1.39E-01 + 4.18E+00 6.86E+00 CS-134 9.53E-01 + 1.66E+00 2.61E+00 CS-1 37 9.02E-01 + 1.48E+00 2.28E+00 BALA140 -1.21EE+00.+ 4.19E+00 6.64E+00 BI-214 3.52E+00 + 4.26E+00 7.67E+00 RA-226 -1.50E+01 + 5.04E+01 6.98E+01 Location 102a collected 4/6/2009 FNuclide RQ Activity Error MDA I Location 102a collected 3/2/2009 FNiiclicde RO Activity Error MDA K-40 1.02E+01 + 2.51E+01 4.99E+01 CR-51 1.80E+00 + 1.86E+01 3.04E+01 MN-54 1.28E-01 + 1.68E+00 2.74E+00 CO-58 1.15E+00 + 1.74E+00 2.67E-,00 FE-59 1.98E+00 + 4.65E+00 7.23E+00 CO-60 4.02E-01 + 1.47E+00 2.34E+00 ZN-65 2.05E+00 + 3.22E+00 4.90E+00 ZRNB-95 3.46E-01 + 1.99E+00 3.23E+00 1-131 3.16E+00 + 4.02E+00 6.24E+00 CS-134 -7.36E-01 + 1.88E+00 3.01 E+00 CS-1 37 -1.29E+00 + 2.13E+00 3.36E+00 BALA140 -6.03E-01 + 4.37E+00 7.06E+00 BI-214 2.43E+00 + 4.63E+00 8.32E+00 RA-226 1.66E+01 + 3.92E+01 7.OOE+01 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA140 BI-214 RA-226 -1.82E+01 + 9.73E+00 + 4.52E-02 + 5.81 E-02 + 0.OOE+00 + -1.94E-01 + 1.23E-01 + 1.84E+00 + 2.75E+00 + 9.25E-01 + 1.63E+00 + -1.24E+00 + 6.64E+00 + -6.01 E+00 + 3.83E+01 2.OOE+01 1.45E+00 2.OOE+00 6.22E+00 1.29E+00 2.62E+00 1.53E+00 4.90E+00 1.70E+00 1.63E+00 .5.30E+00 4.76E+00 4.25E+01 5.19E+01 3.20E+01 2.37E+00 3.27E+00 1.04E+01 2.08E+00 4.27E+00 2.16E+00 7.75E+00 2.69E+00 2.43E+00 8.48E+00 8.16E+00 6.94E+01 f Nuclide RQ K-40 CR-51 MN-54 CO-58 FE-59 0C060 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 RA-226 [-Nuclide RQ Location 1 02a collected ýActivity Error 5/6/2009 .MDA I -3.05E+01 + -7.08E+00 + 9.41 E-01 + 8.03E-01 + 2.68E+00 + 8.49E-01 + 0.OOE+00 + -1.09E-01 + -6.51 E-02 + 1.11 E+00 + 3.13E-01 + -8.90E-04 + 7.18E-01 + -9.15E+00 + 5.45E+01 2.22E+01 2.OOE+00 2.01 E+00 5.69E+00 1.99E+00 6.06E+00 2.05E+00 6.11E+00 1.86E+00 2.12E+00 4.49E+00 4.83E+00 6.07E+01 5.24E+01 3.60E+01 3.18E+00 3.19E+00 8.92E+00 3.14E+00 1.01 E+01 3.36E+00 1.OOE+01 2.95E+00 3.46E+00 7.29E+00 8.77E+00 9.60E+01 Location 102a collected 6/1/2009 7-Nuclide RO Activity Error MDA 1 Location 102a collected 7/1/2009 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA140 BI-214 RA-226 -1.97E+01 + -1.22E+00 + -6.41 E-01 + -4.89E-01 + 1.67E-01 + 1.71 E+00 + 0.OOE+00 + -6.49E-01 + -2.55E+00 + 4.90E-01 + -4.61E-02 + -2.29E-01 + 8.11E-01 + -9.49E+00 + 4.08E+01 1.99E+01 2.06E+00 1.99E+00 3.66E+00 1-.79E+00 6.68E+00 2.28E+00 .5.13E+00 1.89E+00 1.88E+00 .3.67E+00 ,4.28E+00 .5.03E+01 5.29E+01 3.27E+01 3.31 E+00 3.20E+00 5.97E+00 2.63E+00 1.11 E+01 3.68E+00 8.21 E+00 3.06E+00 3.08E+00 5.98E+00 7.93E+00 7.58E+01 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA140 BI-214 RA-226 Activity -3.26E+01 + 7.72E+00 + 7.25E-01 + -8.13E-01 + 2.14E-01 + 3.49E-01 + 6.97E-02 + 5.58E-01 + -1.43E+00 + -2.76E-01 + 1.21 E+00 + -2.15E-01 + -4.28E+00 + 1.02E+01 + Error 5.92E+01 2.50E+01 1.97E+00 2.11E+00 6.36E+0O 1.91 E+00 2.98E+00 2.27E+00 5.77E+00 1.89E+00 2.24E+00 4.09E+00 9.96E+00 5.40E+01 MDA 5.32E+01 4.06E+01 3.15E+00 3.36E+00 1.04E+01 3.09E+00 4.88E+00 3.67E+00 9.38E+00 3.07E+00 3.56E+00 6.68E+00 8.89E+00 9.51 E+01 RO = Results Qualifier. If blank, result is less than detection limit. If "+". result is above detection limit. Page 1 of 4

TABLE B-7.1 GAMMA SPECTROMETRY RESULTS OF SANITARY WASTE TREATMENT WATER STATION 102A Results in pCi/liter, corrected for decay during collection period Location 102a collected 8/3/2009 F-Nu-cli-de RQ Activity Error MDA 7 K-40 -3.42E+01 +, 5.55E+01 5.02E+01 CR-51 9.47E+00 + 2.50E+01 4.05E+01 MN-54 2.00E-02 + 1.85E+00 3.04E+00 CO-58 1.49E-01 + 2.09E+00 3.42E+00 FE-59 -3.46E+00 + 6.42E+00 1.00E+01 CO-60 0.OOE+00 + 2.75E+00 4.58E+00 ZN-65 -1.11 E+00 + 3.96E+00 6.35E+00 ZRNB-95 2.52E-01 + 2.26E+00 3.69E+00 1-131 -2.13E-01 + 5.86E+00 9.62E+00 CS-1 34 4.06E-01 + 1.28E+00 2.(5E+00 CS-1 37 1.44E+00 + 2.08E+00 3.27E+00 BALA140 -2.31 E-01 + 5.06E+00 8.29E+00 BI-214 -1.77E-01 + 5.16E+00 9.09E+00 RA-226 -3.16E-01 + 5.69E+01 9.95E+01 Location 102a collected 8/31/2009 FNuclide RQ Activity Error MDA K-40 -1.38E+01 + 3.47E+01 5.19E+01 CR-51 .1.40E+00 + 2.21E+01 3.62E+01 MN-54 4.16E-02 + 1.73E+00 2.84E+00 CO-58 1.19E+00 + 1.59E+00 2.41 E+00 FE-59 1.88E+00 + 5.41 E+00 8.55E+00 CO-60 1.61 E+00 + 1.71 E+00 2.51 E+00 ZN-65 -2.68E-01 + 3.30E+00 5.38E+00 ZRNB-95 1.57E+00 + 1.96E+00 3.OOE+00 1-131 1.49E-02 + 5.03E+00 8.27E+00 CS-134 5.75E-02 + 1.72E+00 2.82E+00 CS-137 5.09E-01 + 1.82E+00 2.93E+00 BALA 140 -1.25E+00 + 4.30E+00 6.82E+00 BI-214 1.54E+00 + 4.82E+00 8.67E+00 RA-226 8.58E+00 + 4.25E+01 7.55E+01 Location 102a collected Activity Error I Nuclide Ro K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-137 BALA 40 BI-214 RA-226 -2.87E+00 + 2.64E+01 -1.08E+01 + 2.36E+01 3.26E-01 + 1.82E+00 -6.04E-02 + 1.92E+00 0.OOE+00 + 4.97E+00 1.47E+00 + 1.99E+00 1.32E+00 + 3.68E+00 1.59E+00 + 1.99E+00 9.01 E-01 + 6.59E+00 1.01 E-01 + 2.37E+00 -1.54E-03 + 1.80E+00 9.43E-01 + 3.50E+00 2.81 E-01 + 4.63E+00 -4.85E+00 + 4.50E+01 Location 102a collected 10/5/2009 MDA ] 5.07E+01 3.79E+01 2.95E+00 3.15E+00 8.29E+00 3.03E+00 5.83E+00 3.04E+00 1.07E+01 3.88E+00 2.95E+00 5.47E+00 8.48E+00 7.40E+01 F-Nuclide RQ K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA140 BI-214 RA-226 Location 102a collected

Activity, Error

-3.25E+00 + 5.94E-01 + 2.40E-02 + -4.63E-01 + -8.25E-01 + 5.84E-01 + -2.55E-01 + 0.OOE+00 + 6.60E-01 + 0.OOE+00 + -7.69E-01 + -6.02E-01 + 6.44E+00 + 3.92E+01 + 2.73E+01 2.07E+01 1.89E+00 1.96E+00 5.33E+00 1.97E+00 3.78E+00 2.72E+00 5.24E+00 3.47E+00 1.94E+00 4.74E+00 5.46E+00 4.73E+01 11/2/2009 MDA 5.02E+01 3.40E+01 3.11E+00 3.14E+00 8.59E+00 3.12E+00 6.16E+00 4.53E+00 8.55E+00 5.79E+00 3.08E+00 7.67E+00 9.59E+00 8.49E+01 1/4/2010 MDAW7 5.04E+01 3.71 E+01 3.19E+00 3.79E+00 1.04E+01 3.09E+00 1.32E+01 2.92E+00 9.30E+00 3.40E+00 3.15E+00 1.64E+01 9.70E+00 9.49E+01 I I I I I I I I I I I I I I I I I I FNuiiUIde RQ Activity K-40 -9144E+00 + CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA140 BI-214 RA-226 2.35E+00 + 1.10E+00 + -3.19E-01 + 2.99E+00 + -3.15E-01 + -8.69E-01 + -5.06E-01 + 1.18E+00 + 6.55E-02 + -3.32E701 + 7.83E-01 + 2.83E+00 + 2.06E+01 + Lrror 3.48E+01 1.51 E+01 2.29E+00 2.06E+00 4.79E+00 1.72E+00 4.69E+00 2.57E+00 6.48E+00 1.97E+00 1.99E+00 4.58E+00 4.55E+00 4.91 E+01 11/30/2009 DA 5.27E+01 2.46E+01 3.63E+00 3.33E+00 7.15E+00 2.76E+00 7.58E+00 4.16E+00 1.05E+01 3.24E+00 3.22E+00 7.35E+00 8.53E+00 8.87E+01 I Nuclide K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 RA-226 Location 102a collected RQ Activity -1.03E+01 + 0.OOE+00 + 2.52E-01 + -3.49E-01 + -3.80E-02 + -3.54E-02 + 0.OOE+00 + 2.13E+00 + 2.81 E+00 + 1.06E+00 + 7.99E-02 + 0.OOE+00 + -1.71 E+00 + -7.41 E+00 + error 3.32E+01 2.23E+01 1.96E+00 2.33E+00 6.31 E+00 1.88E+00 7.90E+00 1.99E+00 5.85E+00 2.14E+00 1.92E+00 9.84E+00 6.56E+00 5.77E+01 r RO = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 2 of 4

TABLE B-7.1 GAMMA SPECTROMETRY RESULTS OF SANITARY WASTE TREATMENT WATER STATION 102B Results in pCi/liter, corrected for decay during collection period Location 102b collected 2/2/2009 7NucIde i Rl Activity Error MD-A-- Location 102b collected 3/2/2009 rNuclide RQ Aciity -- Error MDA7 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA140 BI-214 RA-226 -1.21E+01 + 1.96E+00 + -4.09E-02 + 6.15E-01 + 7.22E-01 + -4.45E-01 + -7.13E-01 + -3.22E-01 + + 2.03E+02 + 1.13E-01 + -4.17E-01 + 1.59E+00 + 2.02E+00 + -1.14E+01 + 3.11E+01 1.76E+01 1.76E+00 1.65E+00 4.66E+00 1.80E+00 3.75E+00 1.85E+00 1,23E+01 1.75E+00 1.70E+00 3.74E+00 4.31 E+00 5.27E+01 Location 102b collected 4.97E+01 2.87E+01 2.90E+00 2.61 E+00 7.51 E+00 2.88E+00 6.05E+00 3.OOE+00 8.14E+00 2.87E+00 2.74E+00 5.78E+00 7.87E+00 7.64E+01 4/6/2009 MDA7 5.12E+01 3.18E+01 3.OOE+00 2.78E+00 9.86E+00 3.22E+00 5.57E+00 3.50E+00 9.46E+00 2.97E+00 2.80E+00 9.40E+00 7.85E+00 7.33E+01 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 RA-226 -6.05E+00 + 0.OOE+00 + 6.89E-01 + 6.94E-01 + 0.OOE+00 + -1.OOE-01 + 2.33E+00 + 7.23E-01 + -1.62E+00 + -4.63E-01 + 0.OOE+00 + -1.33E-02 + -1.76E+00 + -2.75E+01 + 2.89E+01 1.87E+01 1.53E+00 1.89E+00 2.18E+00 1.63E+00 2.OOE+00 2.06E+00 5.17E+00 1.94E+00 2.17E+00 3.62E+00 5.86E+00 6.38E+01 5.14E+01 3.12E+01 2.40E+00 3.01 E+00 3.63E+00 2.67E+00 2.49E+00 3.29E+00 8.36E+00 3.15E+00 3.61 E+00 5.94E+00 8.04E+00 7.01 E+01 SNuclide K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 RA-226 RQ

  • Activity

-7.23E+00 + -8.90E+00 + -6.89E-01 + 8.06E-01 + -3.99E-02 + 0.OOE+00 + 3.60E-01 + -1.24E+00 + 2.65E-02 + 1.48E-01 + 5.09E-01 + 2.14E+00 + 5.46E-01 + -1.25E+01 + Error 2.95E+01 1.98E+01 1.88E+00 1.77E+00 6.OOE+00 1.93E+00 3.43E+00 2.22E+00 5.76E+00 1.81 E+00 1.74E+00 5.94E+00 4.21 E+00 5.11E+01 Location 102b collected 5/6/2009 7i Nuclide RQ Activity Error MDA K-40 -8.86E+00 + 2.84E+01 4.90E+01 CR-51 6.98E+00 + 1.74E+01 2.79E+01 MN-54 2.83E-01 + 1.60E+00 2.59E+00 CO-58 -1.04E+00 + 2.07E+00 3.26E+00 FE-59 -1.81 E+00 + 5.24E+00 8.27E+00 CO-60 -1.94E-02 + 1.66E+00 2.72E+00 ZN-65 -9.49E-02 + 2.68E+00 4.39E+00 ZRNB-95 -2.47E-01 + 2.1OE+00 3.42E+00 1-131 -1.74E+00 + 5.34E+00 8.62E+00 CS-1 34 -3.89E-02 + 1.64E+00 2.69E+00 CS-1 37 -7'65E-01 + 1.93E+00 3.08E+00 BALA140 1.23E+00 + 3.71E+00 5.81 E+00 BI-214 -3.09E+00 + 7.46E+00 8.05E+00 RA-226 -2.99E+01 + 6,77E+01 7.07E+01 Location 102b collected 7/1/2009 [ NucIlde a R Activity Error MIDA--- Location 102b collected 6/1/2009 Flflu-clIde RQ Activity Error MDA 7 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA140 BI-214 RA-226 1.96E+00 + -9.90E+00 + 0.OOE+00 + 1.07E+00 + 6.32E-01 + 1.36E-01 + 1.94E-02 + 4.48E-02 + -1.02E+00 + 3.49E-01 + -5.52E-02 + -8.42E-01 + -1.63E+00 + -2.53E+01 + 2.47E+01 2.01 E+01 1.89E+00 1.78E+00 4.97E+00 1.91 E+00 3.73E+00 2.03E+00 5.06E+00 1.80E+00 1.63E+00 4.15E+00 5.95E+00 6.59E+01 5.04E+01 3.22E+01 3.1 5E+00 2.75E+00 8.06E+00 3.12E+00 6.13E+00 3.33E+00 8.24E+00 2.93E+00 2.67E+00 6.66E+00 8.28E+00 7.43E+01 K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA 40 BI-214 RA-226 -3.72E+01 + 5.36E+00 + -1.12E-04 + -7.62E-01 + O.OOE+00 + 2.01 E+00 + 0.OOE+00 + -2.55E-01 + 1.89E+00 + -6.78E-01 + 5.99E-01 + 1.1 5E+00 + -2.46E+00 + -2.46E+01 + 6.02E+01 2.08E+01 1.82E+00 2.1 OE+00 6.99E+00 1.95E+00 5.81 E+00 1.97E+00 3.86E+00 2.11E+00 .1.90E+00 4.05E+00 7.38E+00 6.59E+01 5.16E+01 3.37E+01 2.99E+00 3.35E4-00 1.16E+01 2.87E+00 9.68E+00 3.20E+00 6.1 OE+00 3.41 E+00 3.05E+00 6.40E+00 8.71 E+00 7.51 E+01 RQ = Results Qualifier. Ifrblank, result is less than detection limit, If "+". result is above detection limit. Page 3 of 4

TABLE B-7.1 GAMMA SPECTROMETRY RESULTS OF SANITARY WASTE TREATMENT WATER STATION 102B Results in pCi/liter, corrected for decay during collection period Location 102b collected 8/3/2009 FNuici1de RO Activity Error MDA I K-40 -2.93E+01 + 5.03E+01 5.22E+01 CR-51 -1.95E+01 + 2.39E+01 3.78E+01 MN-54 0.OOE+00 + 1.89E+00 3.16E+00 CO-58 -1.01 E+00 + 2.39E+00 3.81 E+00 FE-59 2.05E+00 + 4.62E+00 7.14E+00 CO-60 1.42E+00 + 1.97E+00 3.OOE+00 ZN-65 0.00E+00 + 6.95E+00 1.1 6E+01 ZRNB-95 4.64E-01 + 2.05E+00 3.30E+00 1-131 1.38E+00 + 5.90E+00 9.58E+00 CS-134 5.82E-01 + 2.15E+00 3.48E+00 CS-1 37 7.13E-01 + 1.86E+00 2.97E+00 BALA140 1.57E-01 + 4.50E+00 7.37E+00 BI-214 1.32E-01 + 4.55E+00 8.38E+00 RA-226 -1.OOE+01 + 4.85E+01 7.28E+01 Location 102b collected 8/31/2009 1 Nuclide RO Activity Error MD-A--- K-40 1.54E-01 + 2.57E+01 5.18E+01 CR-51 9.56E+00 +/- 1.90E+01 3.03E+01 MN-54 1.22E+00 + 1.86E+00 2.90E+00 CO-58 -1.20E+00 + 2.50E+00 3.98E+00 FE-59 -2.23E-01 + 4.91 E+00 8.03E+00 CO-60 1.95E+00 + 2.05E+00 3.06E+00 ZN-65 -2.1OE-01 + 4.04E+00 6.62E+00 ZRNB-95 -7.92E-01 + 2.01E+00 3.19E+00 1-131 -2.83E-03 + 5.31E+00 8.83E+00 CS-1 34 -3.30E-01 + 2.05E+00 3.34E+00 CS-1 37 -6.06E-01 + 2.13E+00 3.44E+00 BALA140 7.18E-01 + 4.07E+00 6.54E+00 BI-214 1.07E-01 + 4.64E+00 8.51 E+00 RA-226 -1.28E+00 + 4.38E+01 7.65E+01 Location 102b collected 7-Nuclide RO K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 140 BI-214 RA-226 Activity -2.07E+01 + -1.85E+00 + 1.58E+00 + -3.24E-01 + 3.i8E-02 + 4.23E-01 + -1.18E+00 + 0.OOE+00 + 2.62E-01 + -1.20E+00 + -2.02E-01 + 2.40E+00 + -2.63E+00 + 1.24E+01 + Error 3.67E+01 2.23E+01 1.60E+00 2.07E+00 4.77E+00 1.94E+00 3.59E+00 2.28E+00 7.74E+00 1.97E+00 1.90E+00 5.09E+00 7.03E+00 4.01 E+01 10/5/2009 MDA 4.91 E+01 3.65E+01 2.37E+00 3.36E+00 7.85E+00 3.12E+00 5.69E+00 3.80E+00 1.27E+01 3.12E+00 3.09E+00 7.86E+00 8.20E+00 7.16E+01 Location 102b c I.Nuclide K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA 40 BI-214 RA-226 RQ Activity 1.21 E+01 + 2.02E+00 + 0.OOE+00 + -6.75E-01 + 2.66E+00 + -6.57E-01 + -1.71 E+00 + -3.94E-01 + 3.59E-01 + 4.08E-01 + 1.45E+00 + -2.16E+00 + -1.07E+00 + -1.63E+01 + 2 2 2 2 5 2 4 2 5 2 2 5 5 5

ollected 11/2/2009 Error MDA

] .62E+01 5.04E+01 .67E+01 4.38E+01 .74E+00 4.57E+00 .09E+00 3.33E+00 .96E+00 9.30E+00 .09E+00 3.33E+00

  • .05E+00 6.36E+00

.23E+00 3.62E+00 .33E+00 8.72E+00 .29E+00 3.73E+00 .11E+00 3.27E+00 .55E+00 8.75E+00 .96E+00 9.65E+00 .96E+01 8.89E+01 I I I I I I I I I I I I I Location 102b collected [rNuc[ide Ro Activity Error K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA1 40 BI-214 RA-226 -3.44E+00 + -1.89E+/-00 + 2.99E-01 + 1.94E-02 + 1.78E+00 + 2.09E-03 + -3.20E+00 + O.OOE+00 + 7.64E-02 + 1.76E-01 + -I.71 E-01 + 1.30E+00 + 8.51 E+00 + -8.19E-01 + 2.91 E+01 2.28E+01 1.83E+00 1.91 E+00 5.65E+00 1.18E+00 5.38E+00 2.03E+00 5.73E+00 2.09E+00 2.1 OE+00 4.86E+00 5.38E+00 4.88E+01 11/30/2009 MDA 7 5.22E+01 3.73E+01 2.96E+00 3.14E+00 8.94E+00 1.94E+00 8.42E+00 3.38E+00 9.41 E+00 3.42E+00 3.42E+00 7.71 E+00 9.29E+00 8.88E+01 Nuclide K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA140 BI-214 RA-226 Location 102b collected RO Activity Error -1.91 E+00 + 1.46E+00 + 2.56E-01 + 1.52E-02 + 1.93E+00 + 3.17E-01 + 1.19E-01 + 1.18E+00 + 2.93E+00 + 7.34E-01 + 8.52E-01 + -6.14E-01 + 1.03E+00 + -1.52E+01 + 2.68E+01 2.48E+01 1.71 E+00 2.09E+00 6.24E+00 1.93E+00 4.83E+00 2.1OE+00 7.52E+00 1.55E+00 1.76E+00 5.46E+00 4.82E+00 5.96E+01 1/4/2010 i* DFA----] 5.08E+01 3.97E+01 2.76E+00 3.40E+00 9.74E+00 3.11E+00 7.90E+00 3.22E+00 1.10E+01 2.43E+00 2.76E+00 8.37E+00 9.09E+00 9.OOE+01 I I I I RQ = Results Qualifier. If blank, result is less than detection limit. It "+", result is above detection limit. Page 4 of 4

TABLE B-7.2 GAMMA SPECTROMETRY RESULTS OF SANITARY WASTE TREATMENT WATER -

SUMMARY

Results in pCi per liter, corrected for decay during collection period Location 102A Nuclide K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-137 BALA140 BI-214 RA-226 Average Activity -1.48E+01 1.19E+00 2.40E-01 9.25E-02 2.76E-01 5.01 E-01 1.89E-01 6.59E-01 5.90E-01 3.46E-01 3.03E-01 -3.21 E-01 1.59E+00 3.58E+00 -9.37E+00 -1.23E+00 3.OOE-01 -1.50E-01 6.45E-01 4.19E-01 -3.57E-01 -7.OOE-02 1.71 E+01 -1.70E-02 1.59E-01 2.31 E-01 -2.44E-02 -1.35E+01 Activity Activity Low High -3.42E+01 1.02E+01 -1.08E+01 9.73E+00 -6.41 E-01 1.10E+00 -8.13E-01 1.19E+00 -3.46E+00 2.99E+00 -4.15E-01 1.71 E+00 -1.11E+00 2.05E+00 -6.49E-01 2.13E+00 -2.55E+00 3.16E+00 -7.36E-01 1.11 E+00 -1.29E+00 1.63E+00 -1.25E+00 9.43E-01 -4.28E+00 6.64E+00 -1.50E+01 3.92E+01 Average Number of MDA Samples 5.12E+01 12 3.41 E+01 12 2.97E+00 12 3.17E+00 12 8.70E+00 12 2.91 E+00 12 7.01E+00 12 3.36E+00 12 8.79E+00 12 3.21E+00 12 3.06E+00 12 7.84E+00 12 8.65E+00 12 8.28E+01 12 Number of Positive IDs 0 0 0 0 0 0 0 0 0 0 0 0 0 0 102B K-40 CR-51 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-1 37 BALA1 40 BI-214 RA-226 -3.72E+01 -1.95E+01 -6.89E-01 -1.20E+00 -1.81 E+00 -6.57E-01 .-3.20E+00 -1.24E+00 -1.74E+00 -1.20E+00 -7.65E-01 -2.16E+00 -3.09E+00 -2.99E+01 1.21 E+01 9.56E+00 1.58E+00 1.07E+00 2.66E+00 2.01 E+00 2.33E+00 1.18E+00 2.03E+02 7.34E-01 1.45E+00 2.40E+00 8.51 E+00 1.24E+01 5.08E+01 3.42E+01 2.98E+00 3.23E+00 8.33E+00 2.92E+00 6.74E+00 3.35E+00 9.1 OE+00 3.13E+00 3.08E+00 7.22E+00 8.49E+00 7.74E+01 12 12 12 12 12 12 12 12 12 12 12 12 12 12 Page 1 of 1

TABLE B-8.1 TRITIUM IN SANITARY WASTE TREATMENT WATER Results in pCi per liter Collection Period Location Description RQ Activity Error 102A 102B FFTF-Effluent Monthly Headworks 01/05/09 02/02/09 03/02/09 04/06/09 05/06/09 06/01/09 07/01/09 08/03/09 08/31/09 10/05/09 11/02/09 11/30/09 01/05/09 02/02/09 03/02/09 04/06/09 05/06/09 06/01/09 07/01/09 08/03/09 08/31/09 10/05/09 11/02/09 11/30/09 02/02/09 03/02/09 04/06/09 05/06/09 06/01/09 07/01/09 08/03/09 08/31/09 10/05/09 11/02/09 11/30/09 01/04/10 02/02/09 03/02/09 04/06/09 05/06/09 06/01/09 07/01/09 08/03/09 08/31/09 10/05/09 11/02/09 11/30/09 01/04/10 + + + + + + + + + + + + 2.17E+03 + 2.17E+03 + 2.32E+03 + 2.34E+03 + 2.21 E+03 + 2.25E+03 + 2.01 E+03 + 1.97E+03 + 2.11 E+03 + 2.03E+03 + 2.04E+03 + 2.55E+03 + 1.43E+02 1.43E+02 1.50E+02 1.42E+02 1.42E+02 1.44E+02 1.40E+02 1.42E+02 1.42E+02 1.45E+02 1.41 E+02 1.54E+02 1.01E+02 1.06E+02 1.04E+02 1.04E+02 1.04E+02 1.02E+02 1.03E+02 1.09E+02 1.07E+02 1.07E+02 1.02E+02 1.21 E+02 I I I U I I I I I I I 'i + 3.42E+02 + + 4.30E+02 + 2.44E+02 + + 4.93E+02 + + 4.51 E+02 + + 3.98E+02 + + 3.98E+02 + + 5.38E+02 + + 6.08E+02 + + 3.57E+02 + + 3.86E+02 + + 9.98E+02 + TABLE B-8.2 TRITIUM IN SANITARY WASTE TREATMENT WATER -

SUMMARY

Results in pCi per liter Number of Positive IDs Average Activity Activity Activity Number of Low High Samples Location DescriDtion 102A & 102B 102A FFTF Effluent 1.33E+03 2.44E+02 2.55E+03 2.18E+03 1.97E+03 2.55E+03 2.44E+02 9.98E+02 24 12 12 23 12 102B Monthly Headworks 4.70E+02 11 I! I I I I RQ= results Qualifier. If blank, result is less than detection limit. If "+", result is above the detection limit. Page 1 of 1

Table B-9.1 SPECIAL ISOTOPIC ANALYSIS RESULTS OF MONITORING WELL WATER All results in pCi/liter, decay corrected to collection date Fe-55 1st Q 2009 Collected 1/22/09 to 1/28/09 [Location RQ Activity Error MDC MW-3 -4.16E+01 + 9.20E+01 1.38E+02 MW-5 5.92E+00 + 6.67E+01 1.12E+02 MW-6 4.47E+01 + 5.57E+01 1.11 E+02 MW-7 -2.00E+01 + 6.90E+01 1.05E+02 MW-8 -3.30E+00 + 6.96E+01 1.13E+02 MW-9 3.87E+01 + 5.78E+01 1.13E+02 MW-10 1.71E+01 + 6.82E+01 1.19E+02 MW-i 1 8.00E+01 + 8.75E+01 1.69E+02 MW-12 5.72E+01 + 7.51E+01 1.43E+02 MW-13 2.20E+02 + 9.32E+01. 1.66E+02 MW-1 4 2.74E+01 + 6.94E+01 1.24E+02 Ni-63 1st Q 2009 Collected 1/22/09 to 1/28/09 FNuclide RQ Activity Error MDC MW-3 4.25E+00 + 2.88E+00* 4.50E+00 MW-5 5.54E-01 + 2.01E+00 3.28E+00 MW-6 -4.79E-01 + 1.96E+00 3.26E+00 MW-7 -9.59E-01 + 2.11E+00 3.53E+00 MW-8 4.75E-01 + 1.98E+00 3.23E+00 MW-9 2.90E+00 + 3.02E+00 4.79E+00 MW-10 4.61 E-01 + 2.47E+00 4.04E+00 MW-11 6.58E-01 + 2.64E+00 4.32E+00 MW-12 2.50E+00 + 2.78E+00 4.43E+00 MW-13 2.09E+00 + 2.95E+00 4.71 E+00 MW-14 4.53E-01 + 1.99E+00 3.25E+00 Sr-90 1st 0 2009 Collected 1/22/09 to 1/28/09 FNuclide RQ Activity. Error MDC Fe-55 2nd Q 2009 Collected 4/22/09 to 4/27/09 Nuclide RQ Activity Error MDC MW-3 -2.03E+00 + 5.77E+01 9.42E+01 MW-5 2.40E+00 + 7.51E+01 1.24E+02 MW-6 7.25E+01 + 7.59E+01 1.49E+02 MW-7 8.49E+01 + 6.66E+01 1.40E+02 MW-8 1.91 E+00 + 6.26E+01 1.04E+02 MW-9 -3.33E+01 + 6.68E+01 9.51 E+01 MW-10 -2.25E+01 + 7.99E+01 1.23E+02 MW-11 3.48E+01 + 8.19E+01 1.46E+02 MW-12 4.41E+01 + 6.51E+01 1.24E+02 MW-13 -2.37E+00 + 8.68E+01 1.42E+02 MW-14 1.65E+01 + 7.85E+01 1.35E+02 Ni-63 2nd Q 2009 Collected 4/22/09 to 4/27/09 Nuclide RQ -Activity Error MDC MW-3 -1.56E+00 + 2.28E+00 3.86E+00 MW-5 -2.77E-01 + 2.15E+00 3.57E+00 MW-6 -6.85E-01 + 2.20E+00 3.67E+00 MW-7 0.OOE+00 + 2.08E+00 3.43E+00 MW-8 9.04E-01 + 2.15E+00 3.48E+00 MW-9 5.04E-01 + 2.24E+00 3.66E+00 MW-1 0 -1.46E+00 + 2.56E+00 4.29E+00 MW-1 1 -1.99E+00 + 2.42E+00 4.09E+00 MW-12 -4.30E-01 + 2.13E+00 3.53E+00 MW-13 -5.71E-01 ' 2.11E+00 3.52E+00 MW-14 1.21 E+00 + 2.15E+00 3.46E+00 Sr-90 2nd Q 2009 Collected'4/22/09 to 4/27/09 Nuclide RQ Activity 'Error MDC MW-3 MW-5 MW-6 MW-7 MW-8 MW-9 MW-10 MW-11 MW-12 MW-13 MW-14 2.65E-01 + -3.20E-01 + 2.22E-01 + 0.OOE+00 + -3.77E-01 + 1.53E-01 _+ 5.85E-02 + -3.84E-01 + 4.48E-01 + 9.22E-02 + -2.49E-01 + 4.42E-01 3.66E-01 3.62E-01 4.54E-01 3.88E-01 4.49E-01 3.74E-01 3.22E-01 5.09E-01 3.79E-01 2.95E-01 6.93E-01 6.43E-01 5.63E-01 7.48E-01 6.82E-01 7.20E-01 6.09E-01 5.77E-01 7.82E-01 6.14E-01 5.15E-01 MW-3 MW-5 MW-6 MW-7 MW-8 MW-9 MW-10 MW-11 MW-12 MW-13 MW-14 7.82E-01 + 2.03E-02 + 1.51 E-02 + -2.14E-02 + 5.03E-01 + 3.11E-01 + 1.45E-01 + 3.96E-01 + 3.58E-01 + 3.14E-01 + 5.28E-01 + 5.43E-01 5.41E-01 4.01E-01 2.94E-01 3.58E-01 3.80E-01 3.89E-01 2.86E-01 3.77E-01 4.31 E-01 4.14E-01 8.04E-01 8.89E-01 6.59E-01 4.86E-01 5.30E-01 5.88E-01 6.24E-01 4.23E-01 5.75E-01 6.75E-01 6.20E-01 Page 1 of 1 RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit.

TABLE B-10.1 I GAMMA SPECTROMETRY RESULTS OF GROUNDWATER MONITORING SAMPLES Results in pCi per liter Station MW-3 collected 1/21/2009 -NIui RQ-Ac-iit y Error M D-A Station MW-8 collected 1/21/2009 FNu-cIie-RO---*Activit y Eror MD-A---] K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 I-131 CS-134 CS-137 BALA1 40 BI-214 -7.79E+01 + 0.OOE+00 + -1.56E+00 + 8.08E-01 + 0.OOE+00 + -2.54E+00 + -7.73E-01 + 3.67E-01 + -1.02E+00 + -1.19E+00 + -7.34E-01 + + 3.66E+02 + 1.83E+03 4.66E+00 3.30E+00 7.61 E+00 2.77E+00 3.97E+01 3.82E+00 3.54E+00 2.51 E-01 3.68E+00 4.54E+00 2.20E+01 8.33E+01 7.77E+00 5.18E+00 1.23E+01 4.62E+00 6.53E+01 6.19E+00 5.78E+00 5.85E-01 5.89E+00 7.32E+00 1.36E+01 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 -8.59E+00 + -7.36E-01 + 1.01 E+00 + -2.76E-02 + 8.27E-01 + 3.89E-01 + -1.66E+00 + 2.07E+00 + -1.57E+00 + 1.27E-01 + -1.06E+00 + + 1.05E+02 + 4.65E+01 2,33E+00 2.68E+00 7.06E+00 2.69E+00 7.34E+00 3.83E+00 4.10 E+00 3.45E+00 2.65E+00 5.17E+00 1.31 E+01 7.73E+01 3.66E+00 4.20E+00 1.16E+01 4.22E+00 1.20E+01 6.06E+00 6.47E+00 5.48E+00 4.33E+00 8.25E+00 1.30E+01 Station MW-5 collected 1/21/2009 r-Nu-ci RQ Ac-tivity Eror MD-A-- K-40 -2.03E+01 + 6.47E+01 8.06E+01 MN-54 0.OOE+00 + 3.45E+00 5.74E+00 CO-58 -1.45E-01 + 3.08E+00 5.04E+00 FE-59 2.39E+00 + 7.72E+00 1.22E+01 CO-60 -7.26E-01 + 3.33E+00 5.33E+00 ZN-65 -5.39E+00 + 1.14E+01 1.81 E+01 ZRNB-95 -1.74E+00 + 3.47E+00 5.45E+00 1-131 -1.62E+00 + 3.26E+00 5.17E+00 CS-134 0.OOE+00 + 6.40E+00 1.07E+01 CS-137 1.89E-04 + 3.70E+00 6.03E+00 BALA140 -8.27E-01 + 4.36E+00 6.99E+00 BI-214 + 1.69E+02 + 1.51E+01 1.07E+01 Station MW-6 collected 1/21/2009 [-Nu-clidie-R A-iititV Error 07A ] Station MW-9 collected 1/21/2009 N -1cil Ai-i RQA-itity Error M D-A---] K-40 -2.27E+01 + 6.08E+01 7.52E+01 MN-54 -2.44E-02 + 2.68E+00 4.40E+00 CO-58 -1.13E-01 + 2.48E+00 4.06E+00 FE-59 -7.99E-01 + 5.14E+00 8.17E+00 CO-60 1.65E-03 + 2.66E+00 4.37E+00 ZN-65 3.17E+00 + 3.19E+00 3.77E+00 ZRNB-95 -1.57E+00 + 3.59E+00 5.67E+00 1-131 2.04E-02 + 3.99E+00 6.55E+00 CS-134 -2.16E-01 + 5.71 E+00 9.37E+00 CS-137 O.OOE+00 + 4.91 E+00 8.19E+00 BALA140 1.29E+00 + 3.96E+00 6.11E+00 BI-214 + 1.20E+02 + 1.39E+01 1.20E+01 Station MW-10 collected 1/28/2009 FNu-clide -R-QýA-i ifiy Error MD-. I I I I I U U I I I I I I I I I I K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 -2.05E+01 + -1.89E+00 + 1.53E+00 + 6.86E-01 + -1.11E+00 + -2.11 E+01 + -1.01E-01 + 7.72E-01 + 3.17E-01 + -6.54E-01 + -2.20E-01 + + 3.17E+02 + 6.33E+01 4.21 E+00 2.93E+00 8.01 E+00 3.90E+00 7.69E-01 3.38E+00 2.32E+00 4.35E+00 3.95E+00 4.71 E+00 2.07E+01 7.93E+01 6.68E+00 4.54E+00 1.30E+01 6.22E+00 1.79E+00 5.54E+00 3.69E+00 7.,12E+00 6.40E+00 7.70E+00 1.26E+01 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-i 34 CS-1 37 BALA 40 BI-214 -1.80E+01 + -9.27E-02 + -7.27E-01 + -2.49E+00 + 6.69E-01 + -2.79E+00 + -3.04E-01 + 1.20E+00 + -8.66E-01 + -2.11 E+00 + 9.86E-01 + + 2.51E+02 + 6.19E+01 3.14E+00 2.88E+00 8.09E+00 3.03E+00 7.03E+00 4.01 E+00 2.67E+00 3.43E+00 3.76E+00 3.75E+00 1.84E+01 8.10E+01 5.14E+00 4.60E+00 1.28E+01 4.83E+00 1.10E+01 6.55E+00 4.24E+00 5.54E+00 5.89E+00 5.93E+00 1.27E+01 Station MW-7 collected 1/21/2009 FNUlidile RO Activity Error MD-A---l Station MW-11 collected 1/28/2009 -N1u-cIliel O A-R iciity Error MDA7] K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-137 BALA140 BI-214 -3.86E+01 + 0.OOE+00 + -1.17E+00 + -2.69E+00 + -4.30E-01 + 9.25E-01 + 9.71 E-02 + 2.95E+00 + -5.46E-01 + -6.95E-01 + -1.47E+00 + + 1.17E+02 + 1.06E+02 3.47E+00 3.33E+00 8.15E+00 2.86E+00 6.21 E+00 2.60E+00 4.04E+00 2.76E+00 2.95E+00 5.22E+00 1.40E+01 8.19E+01 5.79E+00 5.29E+00 1.28E+01 4.59E+00 1.OOE+01 4.25E+00 6.27E+00 4.45E+00 4.73E+00 8.25E+00 1.19E+01 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA1 40 BI-214 -2.86E+01 + -7.21 E-01 + 9.31 E-02 + -2.78E+00 + 0.OOE+00 + -2.97E+00 + 0.OOE+00 + 5.38E-01 + 3.41 E-01 + -7.90E-01 + -9.81 E-01 + + 2.59E+02 + 7.18E+01 2.92E+00 2.OOE+00 7.84E+00 2.49E+00 7.33E+00 3.52E+00 3.51 E+00 2.98E+00 3.55E+00 3.88E+00 1.92E+01 7.63E+01 4.66E+00 3.27E+00 1.23E+01 4.16E+00 1.15E+01 5.86E+00 5.72E+00 4.86E+00 5.72E+00 6.13E+00 1.27E+01 RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 1 of 6

TABLE B-10.1 GAMMA SPECTROMETRY RESULTS OF GROUNDWATER MONITORING SAMPLES Results in pCi per liter Station MW-12 collected 1/28/2009 F-N-clidid RQ-A-iiitv ME r-ror MD-A---7 Station MW-5 collected 4/27/2009 FNu-clide -R--Ac-tiviiy .Error-MD-A--7, K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-137 BALA140 BI-214 -4.93E+01 + -1.25E+00 + -3.62E-02 + -1.62E+00 + -3.29E-01 + -1.69E+00 + -2.75E+00 + 1.42E+00 + -2.12E+00 + -8.31E-01 + -1.42E+00 + + 2.46E+02 + 1.48E+02 3.46E+00 2.79E+00 7.24E+00 3.46E+00 3.52E+01 4.63E+00 3.13E+00 3.81 E+00 3.51 E+00 4.59E+00 1.90E+01 8.12E+01 5.49E+00 4.58E+00 1.15E+01 5.63E+00 5.79E+01 7.32E+00 4.97E+00 6.02E+00 5.65E+00 7.25E+00 1.35E+01 K-40 MN-54 0o-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 -1.53E+01 + -4.20E-01 + -5.54E-01 + 2.78E-01 + -7.84E-01 + 8.46E-01 + -3.OOE+00 + 1.24E+00 + -4.81 E-02 + -2.75E-01 + -1.16E+00 + + 2.12E+02 + 5.77E+01 3.09E+00 2.87E+00 7.59E+00 3.49E+00 2.89E+01 4.68E+00 2.62E+00 2.68E+00 5.27E+00 4.09E+00 1.71 E+01 8.06E+01 5.02E+00 4.62E+00 1.24E+01 5.58E+00 4.75E+01 7.37E+00 4.15E+00 4.40E+00 8.63E+00 6.47E+00 1.24E+01 Station MW-13 collected 1/28/2009 [-Nu-clide- -RQ Ac-ti~ity , ;, Error MDA Station MW-6 collected 4/27/2009 [-NI-clile Ro Aciv&ity Error MD7A---- K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-137 BALA 40 BI-214 -2.50E+01 + -6.29E-01 + 4.80E-01 + -9.94E-01 + -2.78E-01 + O.OOE+00 + 8.15E-02 + 1.42E+00 + -1.59E+00 + 1.88E+00 + -1.09E+00 + + 2.64E+02 + 7.90E+01 3.28E+00 2.58E+00 7.74E+00 3.37E+00 3.59E+01 2.85E+00 3.21 E+00 3.83E+00 2.07E+00 4.27E+00 1.94E+01 8.52E+01 5.29E+00 4.14E+00 1.25E+01 5.49E+00 5.99E+01 4.68E+00 5.11E+00 6.12E+00 2.91 E+00 6.78E+00 1.39E+01 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA 40 BI-214 -6.44E+01 + 9.73E-01 + -1.65E+00 + 0.OOE+00 + 1.05E+00 + -1.01E+01 _+ -2.43E+00 + 1.48E-01 + 6.28E-01 + 1.02E+00 + 4.74E-01 + + 2.86E+02 + 3.54E+02 3.07E+00 3.65E+00 8.71 E+00 3.12E+00 1.33E+01 4.07E+00 4.33E+00 3.25E+00 3.26E+00 4.41 E+00 1.89E+01 8.17E+01 4.90E+00 5.79E+00 1.45E+01 4.93E+00 2.09E+01 6.43E+00 7.10E+00 5.28E+00 5.22E+00 7.16E+00 1.38E+01 Station MW-14 collected 1/28/2009 FN-clidiie RQ Activity Error rMD'A--* K-40 -3.75E+01 + 9.76E+01 7.94E+01 MN-54 -1.42E+00 + 3,38E+00 5.33E+00 CO-58 6.14E-01 + 2.56E+00 4.09E+00 FE-59 8.OOE-02 + 4.67E+00 7.64E+00 CO-60 7.46E-01 + 3.OOE+00 4.76E+00 ZN-65 -6.80E+00 + 1.02E+01 1.59E+01 ZRNB-95 -1.27E+00 + 3.66E+00 5.85E+00 1-131 -2.17E-01 + 3.12E+00 5.11E+00 CS-134 -9.54E-01 + 2.97E+00 4.75E+00 CS-137 -9.98E-01 + 3.1 4E+00 5.01E+00 BALA140 -1.13E+00 + 3.97E+00 6.24E+00 BI-214 + 1.67E+02 + 1.61 E+01 1.29E+01 Station MW-3 collected 4/27/2009 FNu-ciei RQ-A-*ctiv ityv 7 Error MDA 77 Station MW-7 collected 4/27/2009 FNu-clie--I RQ Activity

.Errfor MDA

] K-40 -1.68E+01 + 6.78E+01 8.77E+01 MN-54 1.15E+00 + 3.22E+00 5.1OE+00 CO-58 -1.25E-02 + 2.85E+00 4.68E+00 FE-59 1.37E-01 + 7.87E+00 1.29E+01 CO-60 -6.71 E-01 + 3.05E+00 4.87E+00 ZN-65 1.31 E-01 + 6.94E+00 1.14E+01 ZRNB-95 -2.77E+00 + 4.20E+00 6.57E+00 1-131 6.31E-01 + 3.54E+00 5.75E+00 CS-134 4.30E-01 + 7.06E+00 1.16E+01 CS-137 0.OOE+00 + 6.04E+00 1.01E+01 BALA140 8.16E-01 + 4.53E+00 7.29E+00 BI-214 + 3.02E+02 + 2.01 E+01 1.28E+01 Station MW-8 collected 4/27/2009 FNu-lii e--ROAc-iiMy Er-r M D-A---- K-40 MN-54 CO-58 FE-59 CO-60 ZN-.65 ZRNB-95 1-131 CS-134 CS-137 BALA140 BI-214 -2.67E+01 + -1.41 E+00 + -2.03E+00 + 0.OOE+00 + 6.12E-01 + -7.62E+01 + -2.81 E+00 + 1.39E-01 + 1.59E+00 + -2.18E+00 + 2.83E+00 + + 4.65E+02 + 8.14E+01 3.92E+00 4.14E+00 1.30E+01 3.47E+00 2.60E+01 4.36E+00 4.30E+00 1.15E+01 4.18E+00 4.34E+00 2.38E+01 8.16E+01 6.27E+00 6.58E+00 2.17E+01 5.61 E+00 3.95E+01 6.89E+00 7.06E+00 1.88E+01 6.64E+00 6.61 E+00 1.47E+01 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA 40 BI-214 -4.84E+01 + -1.09E+00 + -1.45E+00 + -2.91 E+00 + 1.55E+00 + 0.OOE+00 + -3.90E-02 + 3.07E+00 + -2.55E+00 + 1.39E+00 + 2.22E4-00 + + 2.71E+02 + 1.62E+02 3.63E+00 3.57E+00 9.07E+00 3.61 E+00 3.25E+01 3.86E+00 3.62E+00 3.54E+00 3.41 E+00 ,4.32E+00 1.84E+01 8.30E+01 5.83E+00 5.69E+00 1.44E+01 5.68E+00 5.41 E+01 6.33E+00 5.68E+00 5.56E+00 5.42E+00 6.67E+00 1.32E+01 RO = Results Qualifier. If blank, result is less than detection limit. If "+". result is above detection limit. Page 2 of 6

TABLE B-10.1 1 GAMMA SPECTROMETRY RESULTS OF GROUNDWATER MONITORING SAMPLES Results in pCi per liter Station MW-9 collected 4/27/2009 [FNuclide RO Ac-iivit-y Error MDA7] K-40 -4.72E+00 + 5.04E+01 8.67E+01 MN-54 1.80E+00 + 3.17E+00 4.91 E+00 CO-58 -1.43E-02 + 2.93E+00 4.82E+00 FE-59 1.87E+00 + 7.28E+00 1.15E+01 CO-60 -4.84E-01 + 3.34E+00 5.39E+00 ZN-65 -5.18E+01 + 2.37E+01 3.61E+01 ZRNB-95 -2.44E+00 + 4.17E+00 6.56E+00 1-131 1.48E+00 + 3.08E+00 4.89E+00 CS-134 -1.13E-01 + 3.24E+00 5.30E+00 CS-1 37 9.35E-01 + 3.49E+00 5.159E+00 BALA140 1.34E+00 + 4.23E+00 6.66E+00 BI-214 + 3.08E+02 + 2.01 E+01 1.23E+01 Station MW-13 collected 4/22/2009 F-Nu-clide-RO

Activity, Error MDA-7 K-40

-1.90E+01 + 6.81 E+01 8.50E+01 MN-54 0.OOE+00 + 3.97E+00 6.61 E+00 CO-58 -6.99E-01 + 2.97E+00 4.75E+00 FE-59 -3.20E-03 + 7.93E+00 1.31 E+01 CO-60 1.61 E+00 + 3.07E+00 4.69E+00 ZN-65 -8.43E+00 + 1.14E+01 1.77E+01 ZRNB-95 -2.72E+00 + 4.47E+00 7.05E+00 1-131 0.OOE+00 + 3.94E+00 6.56E+00 CS-134 -1.32E+00 + 3.27E+00 5.20E+00 CS-137 1.44E+00 + 2.98E+00 4.65E+00 BALA140 0.OOE+00 + 8.01E-01 1.34E+00 BI-214 + 2.23E+02 + 1.84E+01 1.32E+01 Station MW-10 collec FNUlide RQ Ac-tivity K-40 -3.53E+01 MN-54 -2.43E-0; CO-58 -6.81 E-01 FE-59 1.01 E+0( CO-60 -5.97E-0, ZN-65 7.77E-01 ZRNB-95 8.51 E-01 1-131 -1.94E+0( CS-134 -2.99E+0( CS-137 0.OOE+0( BALA140 -4.35E-01 BI-214 + 1.87E+0, 2 + 0 + 2 + 0 + 0 + ted 4/22/2009 Error MD-A-- 1.04E+02 8.23E+01 2.93E+00 4.81 E+00 3.22E+00 5.20E+00 7.43E+00 1.20E+01 2.59E+00 4.24E+00 2.77E+01 4.55E+01 3.81E+00 6.17E+00 3.88E+00 6.21 E+00 3.90E+00 6.14E+00 5.13E+00 8.55E+00 3.94E+00 6.39E+00 1.54E+01 1.23E+01 FN~i-lidV K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA1 40 BI-214 -RQ Activity Station MW-14 collected 4/22/2009 Error MD-A---] -4.53E+01 + -1.OOE+00 + 2.77E-01 + -2.23E-02 + 0.OOE+00 + -1.16E+01 + -2.02E+00 + 2.30E-01 + -2.96E+00 + -1.85E-01 + 8.61 E-02 + + 1.68E+02 + 1.55E+02 3.14E+00 3.40E+00 7.86E+00 4.07E+00 6.79E-01 3.92E+00 3.54E+00 4.05E+00 3.01 E+00 4.13E+00 1.64E+01 8.66E+01 5.02E+00 5.55E+00 1.29E+01 6.78E+00 1.57E+00 6.23E+00 5.80E+00 6.39E+00 4.92E+00 6.77E+00 1.36E+01 Station MW-1 1 collected 4/22/2009 rNUCIide-RQ Acivty Error MD-A--- K-40 -4.33E+01 + 1.16E+02 7.94E+01 MN-54 5.63E-02 + 1.86E+00 3.05E+00 CO-58 -5.56E-01 + 2.47E+00 3.95E+00 FE-59 1.71E-02 + 8.10E+00 1.33E+01 CO-60 -1.68E-01 + 2.94E+00 4.80E+00 ZN-65 1.70E+00 + 2.90E+01 4.76E+01 ZRNB-95 -7.86E-01 + 3.53E+00 5.70E+00 1-131 -2.51E-01 + 3.09E+00 5.06E+00 CS-134 -1.56E+00 + 3.19E+00 5.04E+00 CS-137 -1.15E-01 + 3.06E+00 5.OOE+00 BALA140 -9.65E-02 + 4.50E+00 7.38E+00 BI-214 + 2.05E+02 + 1.70E+01 1.26E+01 Station MW-12 collected 4/22/2009 F-Nu6-cIide RQ Ac-ivity Error MD-A---] Station MW-3 collected 7/22/2009 FNu-ciide R-QA-Aiity Error MDA K-40 -4.15E+01 + 1.31 E+02 8.81E+01 MN-54 1.24E+00 + 3.50E+00 5.56E+00 CO-58 -3.98E-01 + 2.84E+00 4.60E+00 FE-59 1.36E+00 + 7.63E+00 1.22E+01 CO-60 3.19E-01 + 3.43E+00 5.58E+00 ZN-65 -1.50E+01 + 1.46E+01 2.26E+01 ZRNB-95 -2.58E+00 + 4.54E+00 7.17E+00 1-131 4.40E-02 + 3.87E+00 6.35E+00 CS-134 -1.65E+00 + 4.13E+00 6.61E+00 CS-1 37 5.84E-02 + 3.80E+00 6.25E+00 BALA 40 0.OOE+00 + 5.91 E+00 9.85E+00 BI-214 + 3.46E+02 + 2.12E+01 1.35E+01 Station MW-5 collected 7/22/2009 FNui-iaie-R Activity Error MDA 1 I I I I I I I I U I I I I I I I I K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA 140 BI-214 -3.36E+01 + -6.77E-01 + 3.27E-02 + 0.OOE+00 + 1.O0E-01 + -1.70E+00 + -1.65E+00 + O.OOE+00 + 1.02E+00 + -1.92E+00 + 1.21 E+00 + + 2.15E+02 + 9.06E+01 3.05E+00 2.84E+00 3.82E+00 2.88E+00 3.32E+01 4.11E+00 3.47E+00 3.29E+00 3.99E+00 3.63E+00 1.73E+01 8.09E+01 4.90E+00 4.66E+00 6.36E+00 4.72E+00 5.45E+01 6.55E+00 5.79E+00 5.28E+00 6.32E+00 5.65E+00 1.27E+01 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA 40 BI-214 -5.59E+01 + 1.O0E-01 + -1.30E+00 + 1.05E+00 + 1.06E+00 + -8.45E+00 + 7.13E+00 + -1.49E+00 + -3.96E+00 + -4.14E-01 + -1.39E+00 + + 1.47E+02 + 1.95E+02 3.31 E+00 3.27E+00 6.36E+00 3.05E+00 1.OOE+01 3.20E+00 3.92E+00 4.10E+00 3.14E+00 4.50E+00 1.36E+01 7.71 E+01 5.42E+00 5.19E+00 1.02E+01 4.81 E+00 1.56E+01 4.19E+00 6.32E+00 6.39E+00 5.11E+00 7.14E+00 1.34E+01 RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 3 of 6

TABLE B-10.1 GAMMA SPECTROMETRY RESULTS OF GROUNDWATER MONITORING SAMPLES Results in pCi per liter Station MW-6 collected 7/23/2009 Fi-u-cide RQ Activity Error MD-A-Station MW-10 collected 7/29/2009 FNu-clilde RO Activity Error MDA ] K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA140 BI-214 -2.24E+01 + -1.14E-01 + -5.40E-02 + -4.92E-02 + 1.22E+00 + -8.59E+00 + -3.15E-01 + -6.31E-01 + 0.OOE+00 + -8.13E-01 + -2.63E-02 + + 1.69E+02 + 6.48E+01 2.78E+00 2.81 E+00 7.98E+00 2.99E+00 1.08E+01 3.98E+00 4.28E+00 5.03E+00 3.18E+00 5.19E+00 1.59E+01 7.83E+01 4.55E+00 4.61 E+00 1.31 E+01 4.64E+00 1.67E+01 6.50E+00 6.97E+00 8.39E+00 5.1 OE+00 8.52E+00 1.18E+01 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 -4.65E+01 + -3.17E-02 + 1.34E+00 + -3.35E-01 + 1.14E+00 + -2.58E+00 + 5.42E+00 + -1.11E+00 + 9.88E-02 + -1.42E+00 + -9.44E-01 + + 1.06E+02 + 1.28E+02 2.50E+00 2.36E+00 6.94E+00 3.18E+00 8.59E+00 3.13E+00 3.12E+00 2.17E-01 3.47E+00 4.47E+00 1.15E+01 7.53E+01 4.1 OE+00 3.63E+00 1.13E+01 5.01 E+00 1.38E+01 4.34E+00 5.03E+00 5.06E-01 5.52E+00 7.17E+00 1.16E+01 Station MW-7 collected 7/23/2009 F-Nu-clidel RQ A--iiiity Eiror M -A-Station MW-1 1 collected 7/29/2009 FN-cliile RQ Activity Error MDA 7 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA 140 BI-214 -5.82E+01 + 1.97E-01 + -4.95E-01 + 0.OOE+00 + -3.33E-01 + -7.02E+00 + 1.13E+00 + -1.97E+00 + -9.92E-01 + -1.59E+00 + -1.17E+00 + + 5.56E+01 + 2.49E+02 2.67E+00 2.75E+00 1.10E+01 2.92E+00 9.57E+00 3.33E+00 4.83E+00 3.04E+00 3.37E+00 4.88E+00 1.02E+01 8.28E+01 4.35E+00 4.43E+00 1.83E+01 4.74E+00 1.49E+01 5.32E+00 7.77E+00 4.89E+00 5.33E+00 7.78E+00 1.31E+01 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-137 BALA 140 BI-214 -4.84E+01 + 7.81E-01 + -5.35E-01 + 1.53E+00 + 1.78E+00 + -1.55E+00 + 1.19E-01 + 1.52E+00 + -5.98E-01 + 2.60E-01 + 3.14E-01 + + 2.20E+02 + 1.56E+02 3.34E+00 3.14E+00 8.38E+00 3.34E+00 2.93E+01 3.84E+00 3.23E+00 1.OOE+01 3.19E+00 3.49E+00 1.71 E+01 8.10E+01 5.38E+00 5.09E+00 1.35E+01 5.17E+00 4.81 E+01 6.31 E+00 5.16E+00 1.64E+01 5.20E+00 5.66E+00 1.30E+01 Station MW-8 collected 7/23/2009 FNucIide RQ Activity Error MD-A---] Station MW-12 collected 7/29/2009 r-NuI--idei RQ Activity Error

MDAk---

K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 -3.92E+01 + 0.OOE+00 + -1.44E+00 + -7.60E-01 + 1.15E+00 + -1.11E+00 + 1.45E-01 + -2.35E+00 + -2.97E-01 + -9.06E-01 + -1.02E-01 + + 1.47E+02 + 9.34E+01 2.70E+00 3.04E+00 8.49E+00 2.92E+00 6.94E+00 2.92E+00 4.86E+00 3.34E+00 3.29E+00 4.66E+00 1.56E+01 7.57E+01 4.50E+00 4.74E+00 1.38E+01 4.53E+00 1.12E+01 4.78E+00 7.76E+00 5.45E+00 5.26E+00 7.64E+00 1.31 E+01 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA 140 BI-214 -2.90E+01 + -4.90E-01 + -1.31 E+00 + 0.OOE+00 + 9.96E-02 + 8.48E-01 + -1.52E-01 + 2.52E+00 + 4.70E-02 + 1.19E+00 + 3.26E-02 + + 1.92E+02 + 8.72E+01 2.97E+00 3.27E+00 8.91 E+00 2.91 E+00 2.92E+01 2.96E+00 2.73E+00 3.58E+00 3.55E+00 4.16E+00 1.70E+01 8.50E+01 4.80E+00 5.17E+00 1.49E+01 4.76E+00 4.80E+01 4.84E+00 4.13E+00 5.88E+00 5.67E+00 6.83E+00 1.26E+01 Station MW-9 collected 7/23/2009 r-N uc I i -RQ A* i*ity Error MDA7] Station MW-1 3 collected 7/29/2009 FN5Iiie-RQ Ac-tivity Error MDA----] K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 F-131 CS-1 34 CS-1 37 BALA 40 BI-214 -1:85E+01 + 3.77E-01 + 3.27E-02 + -1.42E+00 + -3.34E-01 + 0.OOE+00 + -2.94E-02 + -1.38E+00 + 1.26E+00 + 4.83E-01 + -1.02E+00 + + 8.55E+01 + 6.27E+01 2.71 E+00 2.80E+00 7.72E+00 3.09E+00 2.OOE+01 3.82E+00 4.46E+00 2.71 E+00 2.66E+00 5.27E+00 1.18E+01 8.11E+01 4.39E+00 4.59E+00 1.24E+01 5.OOE+00 3.33E+01 6.27E+00 7.16E+00 4.26E+00 4.29E+00 8.43E+00 1.22E+01 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-1 34 CS-1 37 BALA 40 BI-214 -2.96E+01 + 0.OOE+00 + -1.25E+00 + 5.55E+00 + 2.38E+00 + 5.82E+00 + 2.01 E-01 + 1.27E+00 + 9.97E-01 + -7.99E-01 + 1.53E+00 + + 2.35E+02 + 9.57E+01 4.33E+00 3.55E+00 8.34E+00 3.72E+00 4.09E+00 3.68E+00 3.58E+00 9.84E+00 3.37E+00 4.40E+00 1.67E+01 8.63E+01 7.21 E+00 5.67E+00 1.27E+01 5.74E+00 4.91 E+00 6.03E+00 5.77E+00 1.61 E+01 5.43E+00 6.93E+00 1.22E+01 RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 4 of 6

TABLE B-10.1i GAMMA SPECTROMETRY RESULTS OF GROUNDWATER MONITORING SAMPLES Results in pCi per liter Station MW-1 4 collected 7/29/2009 Nuclide RQ Activity Error MDA ] K-40 -4.29E+01 + 1.28E+02 8.09E+01 MN-54 2.76E+00 + 3.05E+00 4.59E+00 CO-58 -1.34E+00 + 3.18E+00 5.03E+00 FE-59 -6.76E-01 + 5.34E+00 8.58E+00 CO-60 -9.86E-02 + 3.18E+00 5.22E+00 ZN-65 -5.16E+00 + 8.82E+00 1.38E+01 ZRNB-95 0.OOE+00 + 4.51 E+00 7.51 E+00 1-131 7.58E-01 + 3.98E+00 6.49E+00 CS-134 -1.04E+00 + 2.89E+00 4.62E+00 CS-137 -7.81E-01 + 3.14E+00 5.05E+00 BALA140 1.07E-01 + 3.59E+00 5.88E+00 BI-214 + 1.36E+02 + 1.40E+01 1.17E+01 Station MW-7 collected 10/27/2009 FNu-clide R-Q Activity Error MDA-K-40 -6.56E+01 + MN-54 5.22E-02 + CO-58 -1.94E-01 + FE-59 2.24E+00 + CO-60 -1.12E+00 + ZN-65 -9.80E-01 + ZRNB-95 5.61 E+00 + 1-131 -4.87E-02 + CS-1 34 -5.27E-01 + CS-1 37 0.OOE+00 + BALA140 7.44E-01 + BI-214 + 1.17E+02 + 3.71 E+03 2.66E+00 3.OOE+00 6.33E+00 3.31 E+00 2.62E+01 3.44E+00 2.25E+00 1.10E+01 3.65E+00 3.95E+00 1.49E+01 1.23E+02 4.37E+00 4.90E+00 9.75E+00 5.19E+00 4.31 E+01 4.69E+00 3.68E+00 1.81 E+01 6.08E+00 6.29E+00 1.37E+01 I I I I I I I I Station MW-3 collected FNu-clidce RO Activity E K-40 -3.32E+01 + 1.0 MN-54 6.06E-01 + 2.8 CO-58 1.37E+00 + 3.1 FE-59 3.65E+00 + 7.4 CO-60 8.87E-02 + 3.5 ZN-65 -1.41E+01 + 1.4 ZRNB-95 -1.68E+00 + 4.0 1-131 8.60E-01 + 3.3 CS-134 -1.58E+00 + 1.4 CS-137 -4.12E-02 + 3.4 BALA140 1.13E-01 + 4.3 BI-214 + 2.36E+02 + 1.8 rror 19E+02 4E+00 8E+00 .8E+00 i4E+00 .3E+01 17E+00 1 E+00

  • 4E+01

,5E+00

OE+00 8E+01 10/27/2009 MDA

] 7.70E+01 4.55E+00 4.99E+00 1.14E+01 5.80E+00 2.21 E+01 6.48E+00 5.33E+00 2.37E+01 5.67E+00 7.04E+00 1.38E+01 Station MW-8 collected 10/27/2009 FNu-clice RQ Activity Error MD-A--] K-40 -3.57E+01 + 1.03E+02 7.10E+01 MN-54 -5.59E-01 + 3.26E+00 5.26E+00 CO-58 -4.01E-01 + 3.03E+00 4.92E+00 FE-59 2.41E-01 + 6.27E+00 1.02E+01 CO-60 1.07E-01 + 3.98E+00 6.53E+00 ZN-65 -8.23E+00 + 1.14E+01 1.78E+01 ZRNB-95 -8.18E-01 + 3.36E+00 5.39E+00 1-131 1.46E+00 + 2.80E+00 4.37E+00 CS-134 -2.47E+00 + 4.03E+00 6.35E+00 CS-1 37 -7.17E-01 + 3.03E+00 4.85E+00 BALA 40 0.OOE+00 + 1.50E+00 2.50E+00 BI-214 + 1.26E+02 + 1.46E+01 1.25E+01 Station MW-9 collected .10/27/2009 FNu-cl Iide RQ-A-c-tii itfy Error MD-A---] Station MW-5 collected 10/27/2009 -Nuclilei R Activity Error MDA 7 K-40 MN-54 CO-58 FE-59 CO-60

  • ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA1 40 BI-214

-2.19E+01 + -1.06E+00 + -1.04E+00 + -3.26E+00 + 7.45E-02 + -7.49E+00 + -6.78E-01 + -2.07E-01 + -2.63E-01 + -5.84E-01 + -1.06E+00 + + 1.13E+02 + 7.79E+01 3.36E+00 2.80E+00 8.30E+00 3.19E+00 1.15E+01 3.23E+00 3.99E+00 1.16E+01 3.51 E+00 4.40E+00 1.54E+01 7.93E+01 5.34E+00 4.40E+00 1.29E+01 5.22E+00 1.81 E+01 5.21 E+00 6.54E+00 1.91 E+01 5.67E+00 6.99E+00 1.45E+01 K-40 -8.22E+01 + MN-54 -5.65E-01 + CO-58 2.71 E-02 + FE-59 4.29E+00 + CO-60 8.16E-01 + ZN-65 -8.50E+00 + ZRNB-95 1.15E+00 + 1-131 -2.12E+00 + CS-134 2.93E-01 + CS-137 1.28E+00 + BALA140 -1.19E+00 + BI-214 + 1.04E+02 + 3.45E+02 2.96E+00 2.74E+00 6.63E+00 3.19E+00 4.81 E+00 3.21 E+00 4.96E+00 2.40E+00 2.90E+00 5.78E+00 1.28E+01 8.35E+01 4.75E+00 4.50E+00 9.60E+00 5.06E+00 4.95E+00 5.07E+00 7.88E+00 3.89E+00 4.51 E+00 9.24E+00 1.27E+01 Station MW-6 collected 10/27/2009 FNu-licie RQ A6-i-ity Er0ror MDA 7 Station MW-10 collected 10/26/2009 FNu-clice-RQ Ac-ivity Error MDA---] K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA 40 BI-214 -1.15E+01 + -4.42E-01 + -8.52E-01 + -7.45E+00 + 2.51 E-02 + -9.56E+00 + 6.16E+00 + 6.16E-01 + -7.89E-01 + -1.27E+00 + 0.OOE+00 + + 1.79E+02 + 4.88E+01 3.23E+00 3.29E+00 1.04E+01 2.84E+00 1.32E+01 3.78E+00 3.64E+00 1.38E+01 3.65E+00 4.98E+00 1.71 E+01 7.15E+01 5.24E+00 5.26E+00 1.58E+01 4.67E+00 2.06E+01 5.29E+00 5.91 E+00 2.27E+01 5.81 E+00 8.29E+00 1.41 E+01 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA140 BI-214 -7.10E-01 + 6.42E-01 + -8.17E-01 + -2.81 E+00 + -3.87E-01 + -8.45E-01 + -2.86E+00 + 1.57E+00 + -1.10E+00 + -1.23E+00 + -8.74E-01 + + 1.64E+02 + 4.24E+01 3.07E+00 3.27E+00 8.17E+00 2.85E+00 2.98E+01 4.77E+00 2.82E+00 3.83E+00 3.66E+00 3.88E+00 1.70E+01 8.16E+01 4.94E+00 5.25E+00 1.28E+01 4.59E+00 4.89E+01 7.55E+00 4.44E+00 6.17E+00 5.84E+00 6.18E+00 1.47E+01 I I I I I I I I I RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 5 of 6

TABLE B-10.1 GAMMA SPECTROMETRY RESULTS OF GROUNDWATER MONITORING SAMPLES Results in pCi per liter Station MW-11 collected 10/26/2009 F-Nu-clile Ro Activity Error MDA 1 Station MW-13 collected FN lidle*-RO Ac-iivity Error 10/26/2009 M D-A-- K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA140 BI-214 -2.33E+01 -8.42E-01 -1.39E-01 -7.16E-02 9.86E-01 8.48E-01 -2.21E-01 -3.53E-01 -3.06E+00 -8.39E-01 -9.27E-01 + 2.01E+02 + + + + + + + + + + + + 6.91 E+01 3.06E+00 2.62E+00 6.63E+00 3.23E+00 2.87E+01 3.13E+00 3.56E+00 4.31 E+00 3.76E+00 4.49E+00 1.82E+01 8.04E+01 4.89E+00 4.28E+00 1.09E+01 5.1 OE+00 4.72E+01 5.12E+00 5.81 E+00 6.79E+00 6.07E+00 7.19E+00 1.43E+01 K-40 MN-54 CO-58 FE-59 CO-60 ZN-65 ZRNB-95 1-131 CS-134 CS-137 BALA 40 BI-214 -2.12E+01 + 5.36E-01 + -8.62E-01 + -1.90E+00 + 2.29E+00 + 3.23E+00 + -1.89E+00 + -1.51 E+00 + 5.76E-01 + -1.19E+00 + -1.22E+00 + + 2.17E+02 + 6.59E+01 3.07E+00 3.09E+00 8.16E+00 3.29E+00 6.17E+00 4.21 E+00 3.63E+00 3.19E+00 3.40E+00 4.31 E+00 1.71 E+01 8.04E+01 4.96E+00 4.93E+00 1.30E+01 4.93E+00 9.46E+00 6.69E+00 5.80E+00 5.17E+00 5.42E+00 6.80E+00 1.17E+01 Station MW-1 2 collected 10/26/2009 rNlide RO ARtivity Error MDA---- K-40 -2.44E+01 + 7.13E+01 8.05E+01 MN-54 -11.08E+00 + 2.98E+00 4.70E+00 CO-58 1.36E+00 + 2.93E+00 4.58E+00 FE-59 0.OOE+00 + 1.21 E+01 2.02E+01 CO-60 1.40E+00 + 2.70E+00 4.08E+00 ZN-65 1.70E+00 + 3.56E+01 5.84E+01 ZRNB-95 -2.02E+00 + 4.22E+00 6.70E+00 1-131 -7.18E-01 + 3.81E+00 6.19E+00 CS-134 2.40E+00 + 2.13E+00 2.99E+00 CS-137 1.23E+00 + 2.89E+00 4.52E+00 BALA140 -3.64E-01 + 4.02E+00 6.52E+00 BI-214 + 2.52E+02 + 1.87E+01 1.26E+01 Station MW-14 collected 10/26/2009 FNiid& R Ac-iivity Error MDA ] K-40 -1.22E+01 + 5.09E+01 7.79E+01 MN-54 1.89E-02 + 3.06E+00 5.03E+00 CO-58 -7.16E-02 + 2.23E+00 3.65E+00 FE-59 -1.88E+00 + 7.85E+00 1.25E+01 CO-60 9.20E-01 + 3.13E+00 4.95E+00 ZN-65 -1.04E+00 + 5.67E+00 9.09E+00 ZRNB-95 -1.32E+00 + 3.54E+00 5.63E+00 1-131 -7.19E-01 + 3.48E+00 5.63E+00 CS-1 34 -2.15E-01 + 5.48E+00 8.99E+00 CS-137 -1.14E+00 + 2.69E+00 4.19E+00 BALA140 -6.16E-01 + 4.06E+00 6.52E+00 BI-214 + 1.36E+02 + 1.45E+01 1.20E+01 TABLE B-10.2 GAMMA SPECTROMETRY RESULTS OF GROUNDWATER MONITORING SAMPLES -

SUMMARY

Results in pCi per liter Average Activity Activity Activity Low High Average Number of Number of MDA Samples Positive IDs Nuclide BALA 40 BI-214 CO-58 CO-60 CS-134 CS-137 FE-59 1-131 K-40 MN-54 ZN-65 ZRNB-95 -1.69E-01 -1.47E+00 2.83E+00 6.84E+00 2.02E+02 5.56E+01 4.65E+02 1.29E+01 -3.58E-01 -2.03E+00 1.53E+00 4.77E+00 3.57E-01 -1.12E+00 2.38E+00 5.06E+00 -6.58E-01 -3.96E+00 2.40E+00 7.90E+00 -3.27E-01 -2.18E+00 1.88E+00 5.65E+00 -1.76E-01 -7.45E+00 5.55E+00 1.25E+01 2.53E-01 -2.35E+00 3.07E+00 5.76E+00 -3.33E+01 -8.22E+01 -7.10E-01 8.17E+01 -1.20E-01 -1.89E+00 2.76E+00 5.12E+00 -6.43E+00 -7.62E+01 5.82E+00 2.70E+01 -3.93E-01 -3.OOE+00 7.13E+00 5.96E+00 44 44 44 44 44 44 44 44 44 44 44 44 0 44 0 0 0 0 0 0 0 0 0 0 RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 6 of 6

TABLE B-11.1 TRITIUM IN MONITORING WELL SAMPLES Results in pCi per liter Location Collection Date RQ Activity Error MW-3 MW-5 MW-6 MW-7 MW-8 01/21/09 04/27/09 07/22/09 10/27/09 01/21/09 04/27/09 07/22/09 10/27/09 01/21/09 04/27/09 07/22/09 10/27/09 01/21/09 04/27/09 07/22/09 10/27/09 01/21/09 04/27/09 07/22/09 10/27/09 + + + + + + + + + + + + 1.14E+03 1.42E+03 1.24E+03 1.31 E+03 1.70E+04 1.70E+04 1.66E+04 1.66E+04 5.37E+03 5.23E+03 5.01 E+03 5.17E+03 1.21 E+02 1.26E+02 1.24E+02 1.26E+02 3.19E+02 3.22E+02 3.17E+02 3.23E+02 1.95E+02 1.96E+02 1.91 E+02 1.96E+02 1.02E+02 1.36E+02 8.90E+01 9.52E+01 1.16E+02 1.11E+02 1.52E+02 1.17E+02 + 3.53E+02 + 1.95E+03 1.63E+01 1.31 E+02 + + + + 9.26E+02 7.35E+02 2.60E+03 9.27E+02 MW-9 01/21/09 + 4.45E+02 + 1 04/27/09 + 3.31 E+02 + 9 07/22/09 2.69E+02 + 1 10/27/09 + 3.86E+02 + 1 MW-IO 01/28/09 + 4.41E+02 + 1 04/22/09 + 5.19E+02 + 1 07/29/09 + 5.27E+02 + 1 10/26/09 + 4.53E+02 + 1 MW-11 01/28/09 + 8.84E+02 + 1 04/22/09 + 7.87E+02 + 1 07/29/09 + 9.62E+02 + 1 10/26/09 + 9.45E+02 + 1 MW-12 01/28/09 + 7.43E+02 + 1 04/22/09 + 7.80E+02 + 1 07/29/09 + 7.64E+02 + 1 10/26/09 + 8.13E+02 + 1 MW-13 01/28/09 + 1.10E+04 + 2 04/22/09 + 1.17E+04 + 2 07/29/09 + 1.14E+04 + 2 10/26/09 + 1.19E+04 + 2 MW-14 01/28/09 + 4.16E+02 + 1 04/22/09 + 3.18E+02 + 9 07/29/09 + 3.29E+02 + 9 10/26/09 + 4.79E+02 + 1 RQ= results Qualifier. If blank, result is less than detection limit. If +, result is above the detection limit. .04E+02 .94E+01 .01 E+02 .02E+02 .04E+02 .06E+02 .03E+02 .04E+02 .15E+02 .13E+02 .14E+02 .23E+02 .12E+02 .12E+02 .10E+02 .14E+02 .63E+02 .70E+02 .64E+02 .79E+02 .04E+02 .98E+01 .78E+01 .05E+02 I I I I I I I I I I I I I I I I I I I Page 1 of 1

Table B-12.1 GROSS ALPHA-BETA RESULTS OF MONITORING WELL WATER Results in pCi/liter Gross Beta 1st 0 2009 Collected 1/22/09 to 1/28/09 Location MW-3 MW-5 MW-6 MW-7 MW-8 MW-9 MW-10 MW-i 1 MW-12 MW-13 MW-14 Gross Beta 2nd Q 2009 Collected 4/22/09 to 4/27/09 Nuclide RQ Activity Error MDC RO Activity + 8.89E+00 + + 1.34E+01 + + 8.75E+00 + 1.06E+00 + + 3.97E+00 + 6.22E-01 + + 4.32E+00 + + 4.44E+00 + + 2.98E+00 + + 1.28E+01 + + 3.27E+00 + Error 1.29E+00 1.33E+00 1.20E+00 6.92E-01 9.69E-01 8.11E-01 1.11 E+00 1.07E+00 1.04E+00 1.39E+00 1.08E+00 MDC 2.69E+00 2.39E+00 2.47E+00 2.26E+00 2.44E+00 2.34E+00 2.77E+00 2.73E+00 2.77E+00 2.70E+00 2.86E+00 MW-3 MW-5 MW-6 MW-7 MW-8 MW-9 MW-10 MW-11 MW-12 MW-13 MW-14 + + + + + + + + + + 5.75E+00 + 1.65E+01 + 1.05E+01 + 1.68E+00 + 5.30E+00 + 3.59E+00 + 4.51 E+00 + 4.33E+00 + 4.81 E+00 + 1.58E+01 + 5.32E+00 + 1.10E+00 1.40E+00 1.25E+00 7.02E-01 9.35E-01 1.03E+00 9.11E-01 9.96E-01 9.93E-01 1.38E+00 9.98E-01 2.30E+00 2.09E+00 2.17E+00 2.03E+00 2.06E+00 2.26E+00 2.14E+00 2.13E+00 2.16E+00 2.11E+00 2.24E+00 Gross Alpha 1st Q 2009 Collected 1/22/09 to 1/28/09 Gross Alpha 2nd Q 2009 Collected 4/22/09 to 4/27/09 Error MDC I Nuclide Nuclide RO Activitv MW-3 MW-5 MW-6 MW-7 MW-8 MW-9 MW-10 MW-i 1 MW-12 MW-13 MW-14 + + + + + + + + + + 1.22E+01 + 3.93E+00 + 5.72E+00 + 1.38E-01 + 4.35E+00 + 5.57E+00 + 9.63E+00 + 6.18E+00 + 9.OOE+00 + 6.53E+00 + 1.09E+01 + 2.82E+00 1.02E+00 1.36E+00 3.82E-01 1.1 6E+00 1.09E+00 1.67E+00 1.27E+00 1.61 E+00 1.25E+00 2.01 E+00 5.85E+00 2.26E+00 2.86E+00 1.59E+00 2.63E+00 2.OOE+00 2.13E+00 1.90E+00 2.11E+00 1.74E+00 2.72E+00 MW-3 MW-5 MW-6 MW-7 MW-8 MW-9 MW-10 MW-11 MW-12 MW-13 MW-14 RO Activity + 1.37E+01 + + 4.19E+00 + + 8.57E+00 + 1.37E+00 + + 2.77E+00 + + 1.72E+01 + + 2.91E+00 + + 9.49E+00 + + 7.64E+00 + + 3.51 E+00 + + 5.53E+00 + Error 2.60E+00 1.02E+00 1.63E+00 5.78E-01 7.91E-01 2.64E+00 9.52E-01 1.57E+00 1.50E+00 9.66E-01 1.52E+00 MDC 3.99E+00 1.89E+00 2.49E+00 1.55E+00 1.66E+00 3.36E+00 2.19E+00 2.14E+00 2.37E+00 1.97E+00 3.11 E+00 RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. Page 1 of I

Table B-13.1 GROSS BETA ON AIR PARTICULATE FILTERS - OTHER LOCATIONS Results in pCi per Cubic Meter 12/30/08 01/06/09 01/13/09 01/20/09 01/27/09 01/06/09 01/13/09 01/20/09 01/27/09 02/03/09 1.06E-02 6.71 E-03 2.78E-02 5.86E-02 2.16E-02 +r + .+ +r + 6.49E-04 5.33E-04 1.03E-03 1.52E-03 9.02E-04 9.21 E-03 9.17E-03 2.49E-02 4.99E-02 1.95E-02 _+ + +¢ +r + 6.12E-04 6.06E-04 9.83E-04 1.39E-03 8.59E-04 02/03/09 02/10/09 3.36E-02 + 1.13E-03 3.55E-02 + 1.16E-03 02/10/09 02/17/09 1.93E-02 + 8.53E-04 1.68E-02 + 8.OOE-04 02/17/09 02/24/09 3.49E-02 + 1.16E-03 3.39E-02 + 1.14E-03 02/24/09 03/03/09 1.15E-02 + 6.79E-04 9.78E-03 + 6.34E-04 03/03/09 03/10/09 9.74E-03 + 6.32E-04 8.08E-03 + 5.86E-04 03/10/09 03/17/09 1.82E-02 + 8.31E-04 1.69E-02 + 8.03E-04 03/17/09 03/24/09 8.98E-03 + 6.11E-04 1.09E-02 + 6.59E-04 03/24/09 03/31/09 8.54E-03 + 6.03E-04 8.08E-03 + 5.95E-04 03/31/09 04/07/09 8.71E-03 + 6.06E-04 9.43E-03 + 6.26E-04 04/07/09 04/14/09 8.35E-03 + 6.05E-04 8.55E-03 + 6.05E-04 04/14/09 05/12/09 1.02E-02 + 3.14E-04 1.12E-02 + 3.31E-04 05/12/09 06/09/09 1.21E-02 + 3.40E-04 1.15E-02 + 3.31E-04 06/09/09 07/07/09 1.14E-02 + 3.32E-04 1.23E-02 + 3.46E-04 07/07/09 08/04/09 1.32E-02 + 3.59E-04 1.42E-02 + 3.73E-04 08/04/09 09/01/09 1.22E-02 + 3.44E-04 1.30E-02 + 3.54E-04 09/01/09 10/06/09 9.72E-03 + 2.74E-04 1.1OE-02 + 2.92E-04 10/06/09 11/03/09 1.50E-02 + 5.24E-04 1.52E-02 + 3.88E-04 11/03/09 12/01/09 1.39E-02 + 3.82E-04 1.69E-02 + 4.09E-04 12/01/09 01/05/10 4.11E-02 + 6.43E-04 4.33E-02 + 6.66E-04 Station 89 Station 90 Collection.Period dResult ~ Error Resujlt Error 12/30/08 01/06/09 1.05E-02 + 6.47E-04 1.05E-02 + 6.36E-04 01/06/09 01/13/09 1.OOE-02 + 6.33E-04 8.09E-03 + 5.75E-04 01/13/09 01/20/09 2.94E-02 + 1.06E-03 2.59E-02 + 1.OOE-03 01/20/09 01/27/09 5.27E-02 + 1.44E-03 5.50E-02 + 1.47E-03 01/27/09 02/03/09 1.81E-02 + 8.31E-04 1.91E-02 + 8.53E-04 02/03/09 02/10/09 3.71E-02 + 1.19E-03 3.48E-02 + 1.15E-03 02/10/09 02/17/09 1.79E-02 + 8.26E-04 1.95E-02 + 8.58E-04 02/17/09 02/24/09 3.30E-02 + 1.13E-03 3.06E-02 + 1.09E-03 02/24/09 03/03/09 1.07E-02 + 6.55E-04 1.28E-02 + 7.12E-04 03/03/09 03/10/09 1.06E-02 + 6.55E-04 1.02E-02 + 6.48E-04 03/10/09 03/17/09 2.06E-02 + 8.82E-04 1.91E-02 + 8.48E-04 03/17/09 03/24/09 8.1OE-03 + 5.84E-04 8.35E-03 + 5.87E-04 03/24/09 03/31/09 8.62E-03 + 6.11 E-04 7.60E-03 + 5.75E-04 03/31/09 04/07/09 9.37E-03 + 6.23E-04 8.28E-03 + 5.93E-04 04/07/09 04/14/09 8.91E-03 + 6.20E-04 6.68E-03 + 5.52E-04 04/14/09 05/12/09 1.13E-02 + 3.33E-04 1.12E-02 + 3.31E-04 05/12/09 06/09/09 1.23E-02 + 3.43E-04 1.14E-02 + 3.29E-04 06/09/09 07/07/09 1.27E-02 + 3.52E-04 1.22E-02 + 3.44E-04 07/07/09 08/04/09 1.68E-02 + 4.09E-04 1.62E-02 + 4.01 E-04 08/04/09 09/01/09 1.50E-02 + 3.84E-04 1.57E-02 + 3.93E-04 09/01/09 10/06/09 1.08E-02 + 2.90E-04 1.11E-02 + 2.94E-04 10/06/09 11/03/09 1.38E-02 + 3.70E-04 1.46E-02 + 3.81 E-04 11/03/09 12/01/09 1.36E-02 + 3.65E-04 1.44E-02 + 3.77E-04 12/01/09 01/05/10 5.17E-02 + 8.08E-04 4.43E-02 + 6.76E-04 I I I I I I I I I I I I I I I I I I I Page 1 of 1

TABLE B-14.1 GAMMA SPECTROMETRY RESULTS OF AIR PARTICULATE FILTERS OTHER LOCATIONS Results in pCi/cubic meter, results decay corrected for decay during sample collection period Location and Quarter Station 87 1st Q 09 SNiuclide RQ Activity Error MDA BE-7 + 8.78E-02 + 1.46E-02 8.85E-03 K-40 -5.39E-03 + 1.31 E-01 1.48E-02 MN-54 1.05E-04 + 4.33E-04 6.72E-04 FE-59 1.70E-03 + 2.93E-03 4.15E-03 CO-60 -1.44E-05 + 4.00E-04 6.50E-04 ZN-65 0.OOE+00 + 1.69E-03 2.82E-03 ZRNB-95 -1.46E-05 + 9.OOE-04 1.48E-03 CS-134 1.23E-05 + 4.19E-04 6.86E-04 CS-137 1.24E-04 + 4.56E-04 7.12E-04 BALA140 -4.30E-04 + 1.19E-02 1.93E-02 RU-106 2.24E-03 + 4.11E-03 6.06E-03 Location and Quarter Station 87 3rd Q 09 [Nuclide RO Activity Error MDA BE-7 + 1.22E-01 + 1.99E-02 1.31 E-02 K-40 -6.51 E-03 + 2.60E-02 1.01 E-02 MN-54 6.63E-06 + 5.75E-04 9.43E-04 FE-59 -8.71 E-05 + 3.24E-03 5.29E-03 CO-60 2.31 E-04 + 6.55E-04 9.99E-04 ZN-65 -4.51 E-04 + 1.63E-03 2.55E-03 ZRNB-95 2.68E-04 + 7.82E-04 1.19E-03 CS-134 8.13E-05 + 5.58E-04 8.99E-04 CS-137 0.OOE+00 + 8.48E-04 1.41 E-03 BALA140 -1.09E-03 + 2.01 E-02 3.26E-02 RU-106 -1.48E-03 + 5.64E-03 8.91 E-03 Location and Quarter Station 88 1St Q 09 [Nuclide RQ Activity Error MDA7] BE-7 + 1.02E-01 + 1.50E-02 6.59E-03 K-40 2.81 E-04 + 6.61 E-03 1.26E-02 MN-54 4.78E-05 + 5.77E-04 9.36E-04 FE-59 1.33E-03 + 1.56E-03 1.53E-03 CO-60 1.95E-05 + 5.17E-04 8.42E-04 ZN-65 -4.65E-04 + 1.47E-03 2.28E-03 ZRNB-95 -1.03E-04 + 8.84E-04 1.43E-03 CS-134 0.OOE+00 + 6.OOE-04 1.OOE-03 CS-137 2.01 E-04 + 5.38E-04 8.32E-04 BALA140 0.OOE+00 + 3.81 E-03 6.35E-03 RU-1 06 4.83E-05 + 4.68E-03 7.69E-03 Location and Quarter Station 88 3rd Q 09 [Nuclide RQ Activity Error MDA ] Location and Quarter Station 87 2nd Q 09 [Nucfide RQ Activity Error MDA BE-7 + 1.36E-01 + 1.93E-02 8.74E-03 K-40 -1.78E-03 + 1.50E-02 1.81 E-02 MN-54 -1.72E-04 + 7.20E-04 1.13E-03 FE-59 -6.26E-04 + 3.95E-03 6.28E-03 CO-60 -1.45E-04 + 7.54E-04 1.19E-03 ZN-65 -4.76E-04 + 1.92E-03 3.03E-03 ZRNB-95 8.17E-04 + 9.36E-04 1.26E-03 CS-134 -1.31 E-04 + 7.18E-04 1.15E-03 CS-137 -3.18E-05 + 6.65E-04 1.08E-03 BALA140 -1.10E-03 + 1.25E-02 2.01 E-02 RU-106 1.31 E-04 + 5.67E-03 9.28E-03 Location and Quarter Stati6 n 87 4th 0 09 lNuclide RQ Acivity Error MDA] BE-7 + 7.07E-02 + 1.31 E-02 6.34E-03 K-40 1.81 E-03 + 4.89E-03 9.35E-03 MN-54 7.30E-05 + 5.15E-04 8.24E-04 FE-59 0.OOE+00 + 3.55E-03 5.92E-03 CO-60 1.75E-04 + 4.58E-04 6.80E-04 ZN-65 -4.69E-04 + 1.40E-03 2.15E-03 ZRNB-95 3.07E-04 + 7.99E-04 1.22E-03 CS-134 0.OOE+00 + 6.34E-04 1.06E-03 CS-137 -9.59E-05 + 5.35E-04 8.56E-04 BALA140 -5.73E-03 + 1.90E-02 2.90E-02 RU-106 -1.31 E-03 + 4.59E-03 7.20E-03 Location and Quarter Station 88 2nd Q 09 [Nuclide RQ Activity Error MDA7 BE-7 + 1.22E-01 + 1.95E-02 1.32E-02 K-40 -4.96E-03 + 3.34E-02 1.64E-02 MN-54 -2.35E-05 + 5.57E-04 9.06E-04 FE-59 0.OOE+00 + 1.04E-03 1.73E-03 CO-60 9.92E-05 + 5.97E-04 9.38E-04 ZN-65 5.69E-04 + 1.27E-03 1.83E-03 ZRNB-95 6.96E-05 + 9.66E-04 1.57E-03 CS-134 2.65E-04 + 6.21 E-04 9.56E-04 CS-137 -1.57E-05 + 4.66E-04 7.60E-04 BALA140 -3.31E-03 + 1.19E-02 1.86E-02 RU-106 5.19E-05 + 5.93E-03 9.74E-03 Location and Quarter Station 88 4th Q 09 [Nuclide RQ Activity Error MDA BE-7 + 7.03E-02 + 1.21 E-02 7.03E-03 K-40 5.33E-04 + 4.28E-03 8.40E-03 MN-54 1.20E-04 + 3.57E-04 5.42E-04 FE-59 -5.08E-04 + 2.26E-03 3.48E-03 CO-60 7.36E-05 + 4.06E-04 6.39E-04 ZN-65 -1.50E-04 + 1.05E-03 1.67E-03 ZRNB-95 -2.38E-06 + 6.26E-04 1.03E-03 CS-134 6.32E-05 + 3.34E-04 5.33E-04 CS-137 6.08E-05 + 3.20E-04 5.06E-04 BALA140 -4.68E-03 + 1.63E-02 2.49E-02 RU-106 0.OOE+00 + 4.09E-03 6.81 E-03 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-1 37 BALA 40 RU-1 06 + 1.33E-01 + -4.51 E-03 + -1.55E-04 + 0.OOE+00 + -8.78E-06 + -1.50E-03 + 1.17E-05 + 0.OOE+00 + 0.OOE+00 + 0.OOE+00 + 1.61 E-03 + 2.04E-02 4.17E-02 7.84E-04 1.17E-03 6.51 E-04 2.55E-03 1.13E-03 1.55E-03 6.52E-04 7.43E-03 5.12E-03 1.14E-02 1.56E-02 1.25E-03 1.96E-03 1.07E-03 3.90E-03 1.86E-03 2.58E-03 1.09E-03 1.24E-02 7.98E-03 RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. 1st 0 1/1/09 to 3/31/09 - 2nd Q 3/31/09 to 6/30/09 - 3rd 0 6/30/09 to 9/29/09 - 4th 0 9/29/09 to 12/29/09 Page 1 of 2

TABLE B-14.1 GAMMA SPECTROMETRY RESULTS OF AIR PARTICULATE FILTERS OTHER LOCATIONS Results in pCi/cubic meter, results decay corrected for decay during sample collection period Location and Quarter Station 89 1St Q 09 [Nu-clide RQ Activity Error MDA ] BE-7 + 9.10E-02 + 1.53E-02 1.02E-02 K-40 4.06E-05 + 6.14E-03 1.20E-02 MN-54 0.OOE+00 + 6.64E-04 1.11E-03 FE-59 3.15E-04 + 2.15E-03 3.37E-03 CO-60 2.OOE-04 + 5.60E-04 8.48E-04 ZN-65 7.25E-04 + 1.30E-03 1.89E-03 ZRNB-95 -1.17E-04 + 7.37E-04 1.17E-03 CS-134 -1.26E-04 + 5.27E-04 8.38E-04 CS-137 -1.26E-04 + 4.45E-04 6.93E-04 BALA140 -5.13E-03 + 1.49E-02 2.30E-02 RU-106 2.61 E-04 + 3.79E-03 6.14E-03 Location and Quarter Station 89 3rd Q 09 [Nuclide RQ Activity Error MDA ] Location and Quarter Station 89 2nd 0 09 [Nuclide RQ Activity Error MDA7 BE-7 + 1.21 E-01 + 1.87E-02 1.22E-02 K-40 -2.15E-03 + 1.42E-02 1.64E-02 MN-54 8.55E-06 + 5.03E-04 8.24E-04 FE-59 -7.52E-05 + 2.99E-03 4.88E-03 CO-60 8.63E-06 + 5.42E-04 8.87E-04 ZN-65 -6.89E-05 + 1.82E-03 2.97E-03 ZRNB-95 2.25E-04 + 8.43E-04 1.31 E-03 CS-134 -1.37E-04 + 6.24E-04 9.94E-04 CS-137 9.86E-05 + 4.41 E-04 6.84E-04 BALA140 -1.56E-03 + 9.89E-03 1.57E-02 RU-1 06 -1.15E-03 + 6.46E-03 1.03E-02 Location and Quarter Station 89 4th Q 09 [*iu-ciide RQ Activity Error MDA I I I I I I. U I I I I I BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-1 37 BALA 40 RU-106 + 1.47E-01 + -1.35E-03 + 1.11E-04 + -9.66E-04 + -1.83E-04 + O.OOE+00 + -3.67E-04 + -7.05E-06 + 0.OOE+00 + 8.24E-03 + -1.18E-03 + 2.05E-02 1.12E-02 5.71 E-04 4.39E-03 7.32E-04 1.89E-03 9.90E-04 5.53E-04 4.44E-04 2.24E-02 5.74E-03 9.83E-03 1.44E-02 9.03E-04 6.91 E-03 1.15E-03 3.15E-03 1.52E-03 9.08E-04 7.40E-04 3.35E-02 9.16E-03 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-1 34 CS-1 37 BALA 40 RU-106 + 7.93E-02 + -1.16E-03 + -7.90E-05 + 8.18E-04 + -1.44E-04 + 1.31 E-04 + O.OOE+00 + -4.63E-05 + -1.73E-04 + 0.OOE+00 + 0.OOE+00 + 1.27E-02 6.96E-03 4.78E-04 2.72E-03 5.13E-04 8.52E-04 4.51 E-04 3.54E-04 3.93E-04 2.11 E-02 3.01 E-03 6.79E-03 8.64E-03 7.65E-04 4.16E-03 7.99E-04 1.35E-03 7.52E-04 5.70E-04 5.98E-04 3.52E-02 5.01 E-03 Location and Quarter Station 90 1st Q 09 [Niuclide RQ Activity Error MDA ] Location and Quarter Station 90 " 2nd 0 09 [4Nuclide RQ Activity Error MDA I BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA140 RU-106 + 9.92E-02 + -2.53E-03 + -1.68E-04 + -2.71 E-04 + 4.45E-05 + -4.08E-05 + 0.OOE+00 + 5.04E-05 + -5.34E-05 + O.OOE+00 + -2.64E-03 + 1.57E-02 1.88E-02 6.08E-04 2.90E-03 5.73E-04 1.27E-03 4.83E-04 3.48E-04 5.01 E-04 3.82E-03 5.87E-03 9.52E-03 1.48E-02 9.55E-04 4.67E-03 9.26E-04 2.07E-03 8.05E-04 5.55E-04 8.08E-04 6.36E-03 9.09E-03 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA 40 RU-106 + 1.16E-01 + -3.46E-03 + 1.72E-04 + -1.13E-03 + 1.84E-04 + 0.OOE+00 + -1.22E-04 + -2.22E-04 + 2.75E-06 + O.OOE+O0 + -1.31 E-03 + 1.77E-02 2.19E-02 6.79E-04 3.64E-03 5.92E-04 3.39E-03 1.01 E-03 7.07E-04 6.28E-04 1.27E-02 5.82E-03 1.05E-02 1.73E-02 1.06E-03 5.59E-03 8.91 E-04 5.64E-03 1.63E-03 1.12 E-03 1.03E-03 2.12E-02 9.21 E-03 Location and Quarter Station 90 3rd Q 09 [NUIiide RQ Ac-tivity Error MDA 1 Location and Quarter Station 90 4th Q 09 [Niclide RQ Activity Error MDA7 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS7134 CS-137 BALA1 40 RU-106 + 1.31 E-01 + -6.51 E-03 + 0.OOE+00 + -5.24E-06 + O.OOE+00 + O.OOE+O0 + 1.99E-04 + -1.03E-04 + 2.46E-05 + -5.16E-03 + 6.08E-04 + 1.96E-02 2.60E-02 3.36E-04 4.18E-03 6.24E-04 3.28E-03 8.69E-04 5.81 E-04 4.87E-04 2.07E-02 4.22E-03 1.03E-02 1.01 E-02 5.59E-04 6.88E-03 1.04E-03 5.46E-03 1.36E-03 9.32E-04 7.93E-04 3.18E-02 6.74E-03 BE-7 K-40 MN-54 FE-59 CO-60 ZN-65 ZRNB-95 CS-134 CS-137 BALA 40 RU-106 + 7.01 E-02 + 6.41 E-04 + -9.90E-05 + 0.OOE+00 + 1.80E-04 + 1.15E-04 + -2.05E-04 + -1.44E-05 + -1.15E-04 + 1.09E-03 + 1.28E-03 + 1.21 E-02 5.63E-03 4.58E-04 3.OOE-03 4.15E-04 1.05E-03 7.36E-04 3.43E-04 3.92E-04 1.42E-02 3.34E-03 6.69E-03 1.03E-02 7.24E-04 5.OOE-03 6.13E-04 1.69E-03 1.15E-03 5.60E-04 6.12E-04 2.29E-02 5.1 OE-03 I I I I I I I RQ = Results Qualifier. If blank, result is less than detection limit. If "+", result is above detection limit. 1st Q 1/1/09 to 3/31/09 - 2nd Q 3/31/09 to 6/30/09 - 3rd Q 6/30/09 to 9/29/09 - 4th Q 9/29/09 to 12/29/09 Page 2 of 2}}