Technical Specification 5.6.6 Steam Generator Tube Inspection 180-Day Report
ML22272A497
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 09/29/2022
From: Tony Brown
Energy Harbor Nuclear Corp
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-22-211
Download: ML22272A497 (90)


Text

energy Energt Harbor Nuclear Corp.

Davis-Besse Nuclear Power Stotion A horbor 5501 N. Stote Route 2 Oak Horbor, Ohio 43449 Terry J. Brown Sife Vice President, Davrs-Besse Nuclear 419-321-7676

September 29,2022 L-22-211

ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

Davis-Besse Nuclear Power Station, Unit No. 1 Docket No. 50-346, License No. NPF-3 Technical Specification 5.6.6 Steam Generator Tube lnspection 180-Dav Report

Energy Harbor Nuclear Corp., in accordance with the Davis-Besse Nuclear Power Station, Unit 1 (DBNPS) Technical Specification (TS) 5.6.6, "Steam Generator Tube lnspection Report," hereby submits a report of the steam generator tube inspections performed pursuant to TS 5.5.8, "Steam Generator (SG) Program." The attached report summarizes the steam generator tube inspections performed during the DBNPS spring 2022 outage.

There are no regulatory commitments contained in this submittal. lf there are any questions, or if additional information is required, please contact Mr. Phil H. Lashley, Manager - Fleet Licensing, at (330) 696-7208.

S

J

Attachment Davis-Besse Nuclear Power Station Steam Generator Tube lnspection Report

cc: NRC Region lll Administrator NRC Resident Inspector NRR Project Manager Utility Radiological Safety Board Attachment L-22-211

Davis-Besse Nuclear Power Station Steam Generator Tube Inspection Report Page 1 of 89

Following completion of a steam generator inspection performed in accordance with the Davis-Besse Nuclear Power Station, Unit 1 (DBNPS) Technical Specification (TS) 5.5.8, Steam Generator (SG) Program, TS 5.6.6, Steam Generator Tube Inspection Report, requires a report of the inspection to be submitted to the Nuclear Regulatory Commission within 180 days after the initial entry into MODE 4. This report summarizes the steam generator tube inspection performed during the DBNPS spring 2022 refueling outage (1R22).

The organization of the report is as follows:

Section 1 Scope of Inspections Performed on Each SG (TS 5.6.6.a)

Section 2 Degradation Mechanisms Found (TS 5.6.6.b)

Section 3 Nondestructive Examination Techniques Utilized for Each Degradation Mechanism (TS 5.6.6.c)

Section 4 Location, Orientation (if Linear), and Measured Sizes (if Available) of Service Induced Indications (TS 5.6.6.d)

Section 5 Number of Tubes Plugged During the Inspection Outage for Each Degradation Mechanism (TS 5.6.6.e)

Section 6 The Number and Percentage of Tubes Plugged to Date, and the Effective Plugging Percentage in Each SG (TS 5.6.6.f)

Section 7 The Results of Condition Monitoring, Including the Results of Tube Pulls and In-Situ Testing (TS 5.6.6.g)

The following is a listing of the more common acronyms and abbreviations that are used throughout this report.

1R22 'DYLV %HVVH 8QLW 6SULQJ 5HIXHOLQJ 2XWDJH

7: 3HUFHQW 7KURXJK :DOO

&02$ &RQGLWLRQ 0RQLWRULQJ DQG 2SHUDWLRQDO $VVHVVPHQW

'%136 ' DYLV %HVVH 1XFOHDU 3RZHU 6WDWLRQ (35, (OHFWULF 3RZHU 5HVHDUFK,QVWLWXWH (766 ([DPLQDWLRQ 7HFKQLTXH 6SHFLILFDWLRQ 6KHHWV

,1&+ /RFDWLRQ RI,QGLFDWLRQ LQ,QFKHV 5HODWLYH WR 763 5HIHUHQFH 3'$ 3HUFHQW 'HJUDGHG $UHD 5HY 5 HYLVLRQ 6* 6WHDP *HQHUDWRU 76 7HFKQLFDO 6SHFLILFDWLRQV 763 7XEH 6XSS RUW 3ODWH

((6 7XEH 6XSSRUW 3ODWH 1XPEHU Attachment L-22-211 Page 2 of 89

Section 1

Scope of Inspections Performed on Each SG (TS 5.6.6.a)

EXAM SCOPE SG 2A SG 1B Eddy Current Full length, bobbin probe [in-service tubes] 15,502 15,538 Special interest, array probe [inspections] 186 145 Visual Previously installed plugs 210 138 Channel head, general 2 2

Attachment L-22-211 Page 3 of 89

Section 2

Degradation Mechanisms Found (TS 5.6.6.b)

Degradation Mechanism SG 2A SG 1B Wear, broached TSP [indications] 2518 869 Wear, drilled TSP [indications] 4 5

Attachment L-22-211 Page 4 of 89

Section 3

Nondestructive Examination Techniques Utilized for Each Degradation Mechanism (TS 5.6.6.c)

The eddy current examinations were performed utilizing various eddy current probes.

All examination techniques utilized were qualified for detection of the relevant degradation mechanisms. This qualification is in accordance with the EPRI SG Examination Guidelines, Revision 8. The applicable Examination Technique Specification Sheets (ETSS) are listed for reference only. Site-specific examination technique sheets are developed prior to each steam generator inspection in accordance with Appendix H or I (as applicable) of the EPRI SG Examination Guidelines, Revision 8.

Degradation Applicability Probe Type Industry Mechanism Qualification Wear Broached TSP Bobbin I-96043.4 Rev. 0

Wear Drilled TSP Bobbin I-96042.1 Rev. 4

Wear Broached & Drilled TSP Array I-11956.3 Rev. 3 I-11956.4 Rev. 3

Attachment L-22-211 Page 5 of 89

Section 4

Location, Orientation (if Linear), and Measured Sizes (if Available) of Service Induced Indications (TS 5.6.6.d)

Wear at Broached TSPs

SG Row Tube TSP INCH %TW 2A 1 4 14S -.52 14 2A 1 5 14S.34 17 2A 1 13 12S -.5 7 2A 2 1 16S.31 12 2A 2 1 16S -.54 21 2A 2 1 14S -.56 2 2A 2 2 16S -. 31 2A 2 2 14S.5 1 2A 2 2 14S -.47 33 2A 2 11 16S.35 24 2A 2 12 16S.3 15 2A 2 13 16S.34 2 2A 2 15 16S -. 31 2A 2 16 16S -.12 35 2A 2 1 12S -.52 1 2A 2 27 16S -.4 1 2A 3 13 16S.42 1 2A 3 17 16S.43 15 2A 3 1 16S.36 13 2A 3 2 16S -. 26 2A 4 2 16S -.67 1 2A 4 2 14S -.62 11 2A 4 2 16S.45 1 2A 4 1 16S.35 1 2A 4 2 16S -.6 1 2A 5 1 16S -.16 31 2A 5 1 15S -.56 1 2A 5 1 15S -. 1 2A 5 2 16S.37 15 2A 5 21 15S -.5 13 2A 5 22 15S.42 11 2A 5 23 15S -.57 12 2A 6 1 16S -.14 37 2A 6 1 14S -.52 1 2A 6 2 16S.37 1 2A 6 6 16S.2 15 Attachment L-22-211 Page 6 of 89

SG Row Tube TSP INCH %TW 2A 6 15 15S.46 17 2A 6 16 15S -.54 17 2A 6 17 15S -.54 14 2A 6 1 15S.42 1 2A 6 2 15S.37 17 2A 6 22 15S.46 13 2A 6 23 15S -.61 15 2A 6 24 16S.35 11 2A 7 1 16S -.14 3 2A 7 13 15S -. 7 1 2A 7 14 15S -.63 11 2A 7 15 15S -.56 13 2A 7 16 15S -. 7 1 2A 7 17 15S -.5 12 2A 7 1 15S -.61 1 2A 7 1 15S -.61 17 2A 7 2 15S.33 12 2A 7 21 15S -.56 1 2A 7 22 15S.53 1 2A 7 22 15S -.63 15 2A 7 23 16S -.1 27 2A 7 25 15S -.54 17 2A 7 27 15S.3 2 2A 14 16S.47 16 2A 14 15S.42 13 2A 14 15S -.54 1 2A 17 15S.4 11 2A 1 15S -.61 14 2A 2 15S -.54 14 2A 22 15S.51 1 2A 23 15S.3 22 2A 24 15S.37 17 2A 26 15S -.63 11 2A 27 15S.53 13 2A 32 15S.32 12 2A 35 15S.46 12 2A 1 16S -.21 43 2A 1 14S -.57 12 2A 2 14S -.57 12 2A 11 15S.44 14 2A 15 15S.35 14 2A 16 15S -.61 16 Attachment L-22-211 Page 7 of 89

SG Row Tube TSP INCH %TW 2A 1 15S -.5 2A 23 16S.4 11 2A 24 15S.51 13 2A 26 15S.2 16 2A 27 16S -.14 16 2A 1 3 16S.27 17 2A 1 1 15S.46 1 2A 1 11 16S.3 15 2A 1 11 15S.42 16 2A 1 11 14S -.57 1 2A 1 16 15S -.63 1 2A 1 17 15S -.61 11 2A 1 1 15S.4 1 2A 1 22 15S -.61 1 2A 1 4 16S -.71 12 2A 1 4 15S.52 2A 1 55 16S.22 11 2A 11 1 16S -.16 36 2A 11 1 14S -.57 24 2A 11 1 15S.47 15 2A 11 11 15S -.5 1 2A 11 13 16S.27 16 2A 11 27 15S.47 11 2A 11 3 15S.51 12 2A 11 67 16S -.14 2 2A 12 1 16S 3 2A 12 2 14S -.55 13 2A 12 6 16S.31 17 2A 12 1 15S -.54 22 2A 12 11 15S.46 1 2A 12 11 15S -.57 14 2A 12 13 16S.24 16 2A 12 14 15S -.56 17 2A 12 23 15S -.11 1 2A 13 15S -.5 12 2A 13 11 15S -.56 11 2A 13 12 15S.42 1 2A 13 12 14S -.57 1 2A 13 13 15S.43 15 2A 13 16 15S.42 2 2A 13 23 15S -.6 1 2A 13 47 15S.52 11 Attachment L-22-211 Page 8 of 89

SG Row Tube TSP INCH %TW 2A 13 73 16S -.7 11 2A 14 1 14S -.57 15 2A 14 2 14S -.57 14 2A 14 6 16S 21 2A 14 15S.44 16 2A 14 15S -.5 21 2A 14 11 15S -.61 11 2A 14 12 15S.46 13 2A 14 13 16S 1 2A 14 41 15S.47 16 2A 14 75 16S 17 2A 15 1 14S -.57 17 2A 15 1 16S 3 2A 15 2 14S -.54 13 2A 15 15S -.57 21 2A 15 15S.44 14 2A 15 1 15S -.5 1 2A 15 11 15S.37 16 2A 15 15 16S.3 11 2A 15 25 15S.4 1 2A 15 53 15S -.57 12 2A 15 53 14S -.56 12 2A 15 57 15S -.6 1 2A 15 63 15S -.61 16 2A 16 1 16S -.11 31 2A 16 1 14S -.53 14 2A 16 16S -.62 13 2A 16 16S.37 11 2A 16 15S 25 2A 16 15S.4 17 2A 16 1 15S -.57 14 2A 16 11 15S.3 15 2A 16 12 16S -.57 17 2A 16 12 15S.3 21 2A 16 13 15S.46 1 2A 16 14 16S.33 17 2A 16 23 15S.3 1 2A 17 7 15S 24 2A 17 15S 23 2A 17 15S.46 13 2A 17 1 15S.45 15 2A 17 11 15S.46 1 Attachment L-22-211 Page 9 of 89

SG Row Tube TSP INCH %TW 2A 17 12 15S -.5 15 2A 17 13 15S.4 12 2A 17 23 15S -.54 24 2A 17 32 13S 1 2A 17 5 15S 16 2A 17 52 15S -.6 17 2A 17 2 16S -.13 26 2A 1 1 16S -.11 31 2A 1 1 14S -.55 13 2A 1 16S -.5 2A 1 15S.4 15 2A 1 16S.33 13 2A 1 16S -.67 15 2A 1 15S.4 11 2A 1 15S -.57 21 2A 1 1 15S -.57 14 2A 1 11 15S -.57 12 2A 1 12 15S -.5 14 2A 1 13 16S -.63 1 2A 1 13 15S -.5 15 2A 1 16 15S -.57 11 2A 1 22 16S -.75 12 2A 1 25 15S.46 12 2A 1 54 15S.42 12 2A 1 7 15S -.61 12 2A 1 15S 1 2A 1 15S.44 14 2A 1 1 15S.44 15 2A 1 12 15S -.57 2 2A 1 13 15S -.64 1 2A 1 15 15S.42 11 2A 1 17 15S -.5 11 2A 1 57 15S 2 2A 1 5 15S -.62 12 2A 1 61 15S 1 2A 1 65 15S.52 14 2A 1 6 16S -.1 33 2A 2 1 16S.33 16 2A 2 1 16S -.55 24 2A 2 7 15S.4 13 2A 2 7 15S -.61 14 2A 2 15S -.5 2 Attachment L-22-211 Page 10 of 89

SG Row Tube TSP INCH %TW 2A 2 1 15S -.5 16 2A 2 11 15S -.5 16 2A 2 13 15S.42 15 2A 2 16 16S -.62 11 2A 2 61 15S.5 12 2A 2 61 15S -.61 11 2A 2 65 15S 2 2A 2 76 15S -.62 11 2A 2 76 14S -.46 12 2A 21 15S -.61 16 2A 21 1 15S.44 14 2A 21 1 15S -.57 14 2A 21 11 15S.5 13 2A 21 12 15S -.5 13 2A 21 13 15S.3 25 2A 21 56 15S -.52 13 2A 21 62 14S -.62 13 2A 21 16S -.16 1 2A 21 16S -.13 22 2A 22 1 16S -.11 3 2A 22 1 14S -.57 13 2A 22 7 15S.4 15 2A 22 7 15S -.63 12 2A 22 15S.46 1 2A 22 15S -.61 1 2A 22 11 15S.43 1 2A 22 16 16S -.7 13 2A 22 56 15S 17 2A 22 62 15S.41 11 2A 22 66 15S -.53 13 2A 23 3 16S.27 14 2A 23 7 15S -.5 17 2A 23 15S 1 2A 23 15S -.5 12 2A 23 1 15S -.63 11 2A 23 12 15S -.57 14 2A 23 36 16S -.72 2A 23 57 15S -.54 13 2A 23 64 15S.45 12 2A 23 66 15S -.4 15 2A 23 6 15S -.65 12 2A 23 1 16S -.73 13 Attachment L-22-211 Page 11 of 89

SG Row Tube TSP INCH %TW 2A 24 7 15S -.57 17 2A 24 1 15S.4 16 2A 24 13 16S -.63 14 2A 24 16 15S.46 1 2A 24 16 15S -.57 12 2A 24 1 16S -.7 2A 24 4 15S -.55 11 2A 24 57 15S.4 16 2A 24 57 15S -.57 15 2A 24 5 16S -.11 22 2A 25 1 16S.33 2 2A 25 7 15S.46 22 2A 25 7 15S -.5 2A 25 15S.41 15 2A 25 26 15S 21 2A 25 36 16S.33 11 2A 25 5 15S.44 15 2A 25 5 15S -.52 11 2A 25 65 15S 11 2A 25 66 15S 2 2A 25 3 16S -.7 21 2A 26 6 15S -.61 11 2A 26 15S -.5 2A 26 1 15S.4 12 2A 26 1 15S -.5 16 2A 26 1 16S -.67 11 2A 26 35 16S -.7 13 2A 26 5 15S -.54 1 2A 26 67 14S -.57 7 2A 26 72 15S 17 2A 26 15S.45 1 2A 26 16S -.16 35 2A 27 6 15S.46 23 2A 27 15S -.5 15 2A 27 11 15S.44 2 2A 27 11 15S -.64 1 2A 27 12 15S.46 22 2A 27 13 15S -.55 2A 27 15 15S -.61 15 2A 27 1 16S -.14 1 2A 27 63 15S.35 16 2A 27 66 15S 15 Attachment L-22-211 Page 12 of 89

SG Row Tube TSP INCH %TW 2A 27 67 15S.4 12 2A 27 6 15S -.4 13 2A 27 71 15S 14 2A 27 73 15S 24 2A 27 74 15S 15 2A 27 1 16S -.1 37 2A 2 15S -.57 15 2A 2 11 15S.5 12 2A 2 5 15S -.55 12 2A 2 6 15S 11 2A 2 7 15S.4 13 2A 2 72 15S.35 16 2A 2 72 15S -.55 11 2A 2 74 15S.4 11 2A 2 1 16S -.11 31 2A 2 6 15S -.57 16 2A 2 7 15S -.57 11 2A 2 15S.43 21 2A 2 1 14S -.57 13 2A 2 57 15S -.52 12 2A 2 64 15S -.53 12 2A 2 65 15S 16 2A 2 15S.45 17 2A 2 2 15S -. 7 16 2A 3 7 15S.3 16 2A 3 7 15S -.5 14 2A 3 1 15S -.62 13 2A 3 14 16S.35 2A 3 14 16S -.6 12 2A 3 17 15S.4 13 2A 3 53 15S -.53 13 2A 3 3 15S -.57 17 2A 3 1 5 16S -.1 4 2A 31 6 15S.54 12 2A 31 6 15S -.56 1 2A 31 7 15S.32 17 2A 31 15S 16 2A 31 1 15S.4 15 2A 31 17 15S -.54 12 2A 31 1 15S -. 5 2 2A 31 5 15S.46 11 2A 31 5 15S -.5 1 Attachment L-22-211 Page 13 of 89

SG Row Tube TSP INCH %TW 2A 31 61 15S -.51 15 2A 31 63 15S -.6 2A 31 64 15S -.55 14 2A 31 77 15S 17 2A 31 3 15S -.57 21 2A 31 1 6 16S -.15 37 2A 32 6 15S -.56 14 2A 32 11 15S.43 16 2A 32 2 16S 1 2A 32 34 15S -.55 11 2A 32 3 15S -. 1 2A 32 3 14S -.57 2A 32 1 15S 13 2A 32 7 15S.45 13 2A 32 1 15S.43 12 2A 32 4 16S -.5 14 2A 32 1 5 16S -. 1 13 2A 32 1 7 16S -.13 2 2A 33 5 15S -.5 11 2A 33 7 15S -.64 14 2A 33 15S -.5 12 2A 33 1 15S.41 1 2A 33 12 15S.44 15 2A 33 14 16S.35 11 2A 33 14 16S -.6 11 2A 33 5 15S.44 2A 33 63 15S 14 2A 33 77 15S 15 2A 33 7 15S.4 11 2A 33 1 15S 13 2A 33 15S.41 15 2A 33 5 15S -.11 23 2A 33 16S -.11 1 2A 33 1 5 16S -.12 27 2A 33 1 6 16S -.61 13 2A 33 1 16S.37 13 2A 34 5 15S.4 16 2A 34 6 15S.44 13 2A 34 7 16S -.57 17 2A 34 1 15S.51 12 2A 34 5 15S -.55 2A 34 61 15S -.53 Attachment L-22-211 Page 14 of 89

SG Row Tube TSP INCH %TW 2A 34 6 15S.3 2A 34 15S.45 12 2A 34 15S -.57 15 2A 34 15S -.53 17 2A 35 7 15S -.5 1 2A 35 16S -.57 1 2A 35 15S -.5 15 2A 35 11 15S -.57 17 2A 35 2 16S -.72 11 2A 35 57 15S.42 12 2A 35 66 15S 12 2A 35 7 15S -.53 13 2A 35 75 15S -.53 15 2A 35 7 16S -.7 11 2A 35 6 15S -.6 1 2A 35 15S.43 2 2A 35 15S -.55 1 2A 35 1 3 16S -.55 12 2A 35 1 6 16S -.54 12 2A 35 11 16S -.11 12 2A 36 1 16S 2 2A 36 11 15S -.5 16 2A 36 55 13S -.52 13 2A 36 5 15S.52 1 2A 36 5 15S -.6 12 2A 36 71 15S.37 16 2A 36 73 15S 12 2A 36 2 15S -.4 11 2A 36 5 16S -.7 1 2A 36 16S -.14 17 2A 36 1 5 16S -.5 2A 36 1 16S -.62 15 2A 37 1 16S -. 21 2A 37 1 14S 1 2A 37 15S -.5 2A 37 1 15S -.61 1 2A 37 11 15S -.64 2A 37 7 15S -.6 12 2A 37 73 15S -.54 11 2A 37 7 15S -.13 21 2A 37 3 15S.3 15 2A 37 3 15S -.54 2 Attachment L-22-211 Page 15 of 89

SG Row Tube TSP INCH %TW 2A 37 3 15S -.45 13 2A 37 4 15S -.55 15 2A 37 6 15S.41 16 2A 37 6 15S -.57 16 2A 37 1 6 16S -.7 13 2A 37 1 7 16S -.64 12 2A 3 2 16S -.62 13 2A 3 3 16S -.6 1 2A 3 7 15S -.61 13 2A 3 1 15S -.57 1 2A 3 12 15S.5 11 2A 3 1 16S -.6 14 2A 3 3 16S.53 14 2A 3 2 15S -.66 12 2A 3 3 15S -.54 15 2A 3 5 16S -.61 14 2A 3 1 5 16S -.63 15 2A 3 1 16S -. 23 2A 3 1 15S -.62 11 2A 3 24 16S -.71 15 2A 3 33 15S.41 17 2A 3 5 15S -.57 1 2A 3 64 15S -.55 13 2A 3 1 15S -.5 1 2A 3 7 15S.36 2A 3 3 15S.4 1 2A 3 7 15S -.57 15 2A 3 1 15S -. 7 1 2A 3 1 7 16S -.63 12 2A 3 1 16S.36 13 2A 3 112 16S -.14 3 2A 3 116 16S -.64 1 2A 4 15S.4 14 2A 4 15S -.61 1 2A 4 1 15S.46 1 2A 4 11 15S -.57 12 2A 4 61 15S -.55 11 2A 4 7 15S -.57 2 2A 4 4 15S.53 13 2A 4 15S 2 2A 4 1 7 16S -.6 11 2A 41 4 15S.4 2 Attachment L-22-211 Page 16 of 89

SG Row Tube TSP INCH %TW 2A 41 15S -.5 11 2A 41 1 15S.46 13 2A 41 24 16S -.55 12 2A 41 2 15S -.6 1 2A 41 6 15S.46 1 2A 41 7 15S.46 11 2A 41 15S.42 16 2A 41 1 15S -.52 16 2A 41 1 1 15S.43 12 2A 41 1 5 15S.36 13 2A 41 1 5 15S -.57 13 2A 41 1 6 16S -.65 1 2A 41 1 7 16S -.7 1 2A 41 113 16S -.1 37 2A 41 115 16S -.66 1 2A 42 4 16S -.6 16 2A 42 4 15S -.61 12 2A 42 4 14S -.52 2A 42 5 16S -.5 11 2A 42 1 15S -.54 11 2A 42 15S -.13 16 2A 42 1 15S.41 22 2A 42 1 6 16S -.67 11 2A 42 1 16S -.6 14 2A 42 113 16S -.6 14 2A 42 113 15S -. 7 13 2A 42 115 16S -.72 13 2A 42 116 16S -.73 16 2A 43 4 15S 24 2A 43 27 16S -.75 15 2A 43 31 16S -.63 17 2A 43 2 15S -.63 11 2A 43 6 15S.45 11 2A 43 1 5 15S.3 1 2A 43 113 16S -.72 13 2A 43 11 11S.41 15 2A 44 4 15S 1 2A 44 5 16S -.55 13 2A 44 5 15S.51 2A 44 5 15S -.6 23 2A 44 7 15S 1 2A 44 16S -.57 12 Attachment L-22-211 Page 17 of 89

SG Row Tube TSP INCH %TW 2A 44 13 15S.51 2A 44 14 15S -.64 17 2A 44 1 16S -.5 12 2A 44 21 16S -.6 1 2A 44 74 15S.45 14 2A 44 74 15S -.5 12 2A 44 5 15S.43 14 2A 44 15S -.61 11 2A 44 1 15S.43 14 2A 44 4 16S -.64 12 2A 44 15S.4 15 2A 44 1 16S -.72 12 2A 44 1 15S.36 12 2A 44 1 2 15S.3 13 2A 44 1 2 15S -.54 15 2A 44 1 3 16S -.72 14 2A 44 11 15S.36 14 2A 44 11 16S -.11 31 2A 44 11 11S.5 14 2A 45 7 15S -.64 1 2A 45 12 15S -.5 16 2A 45 16 15S -.63 13 2A 45 2 16S -.55 13 2A 45 1 15S -.63 12 2A 45 1 15S -.14 14 2A 45 15S -.54 13 2A 45 15S.4 16 2A 45 1 2 15S -. 7 1 2A 45 1 5 16S -.72 15 2A 45 1 5 15S -. 5 17 2A 45 115 15S.36 12 2A 45 117 16S -.11 25 2A 45 11 16S -.6 13 2A 45 11 16S -.67 16 2A 45 12 16S -.14 3 2A 46 1 14S -.5 6 2A 46 5 15S.4 1 2A 46 6 15S -.55 16 2A 46 15S -.6 11 2A 46 13 16S -.52 2A 46 22 16S -.6 13 2A 46 26 16S -.54 15 Attachment L-22-211 Page 18 of 89

SG Row Tube TSP INCH %TW 2A 46 7 15S -.63 12 2A 46 5 15S -.5 2A 46 1 15S -.5 13 2A 46 15S -. 1 2A 46 1 1 15S -. 5 24 2A 46 1 2 15S.34 1 2A 46 1 3 15S -. 24 2A 46 1 5 16S -.71 16 2A 46 1 5 15S -. 21 2A 46 1 16S -.67 17 2A 46 111 15S -. 7 1 2A 46 117 16S -.6 14 2A 46 121 16S -.7 11 2A 47 5 15S -.5 2A 47 6 14S -.55 11 2A 47 6 15S 16 2A 47 1 15S.4 16 2A 47 11 15S -.63 1 2A 47 17 15S -.64 1 2A 47 24 16S -.55 1 2A 47 2 16S.51 12 2A 47 6 13S -.57 2A 47 15S -.61 2A 47 5 15S.36 22 2A 47 121 16S -.14 24 2A 47 122 16S -.13 23 2A 4 5 15S 1 2A 4 6 15S -.5 16 2A 4 7 15S.46 14 2A 4 1 16S -.5 12 2A 4 11 16S -.55 1 2A 4 12 16S -.57 12 2A 4 2 15S 26 2A 4 27 16S -.63 1 2A 4 33 16S -.1 14 2A 4 36 16S -.72 14 2A 4 4 16S.53 2A 4 1 3 15S.43 12 2A 4 1 4 16S -.63 13 2A 4 1 7 16S -.65 15 2A 4 1 7 15S -.14 16 2A 4 1 16S -.63 15 Attachment L-22-211 Page 19 of 89

SG Row Tube TSP INCH %TW 2A 4 12 16S -.72 14 2A 4 122 16S -.6 1 2A 4 123 16S -.13 2 2A 4 6 15S.45 12 2A 4 6 15S -.5 1 2A 4 7 16S -.53 12 2A 4 15S 1 2A 4 15S -.5 2A 4 1 16S -.5 11 2A 4 2 16S -.57 1 2A 4 32 16S -. 2 13 2A 4 5 15S.41 1 2A 4 1 3 15S.41 15 2A 4 1 3 15S -.54 12 2A 4 1 7 16S -.67 13 2A 4 1 15S.3 1 2A 5 4 15S -.5 22 2A 5 5 15S -.55 13 2A 5 6 15S -.5 21 2A 5 1 16S.33 11 2A 5 4 15S.41 13 2A 5 6 15S -.6 12 2A 5 16S -.61 2A 5 1 1 15S.43 13 2A 5 1 7 15S -.5 1 2A 5 11 16S -.64 1 2A 51 4 15S -.62 1 2A 51 5 16S -.53 14 2A 51 5 15S -.6 1 2A 51 6 15S 16 2A 51 15S.51 11 2A 51 2 16S -.77 14 2A 51 33 16S -.7 14 2A 51 35 16S.47 16 2A 51 15S.43 11 2A 51 1 16S -.16 21 2A 51 1 15S -. 7 2 2A 51 124 16S -.14 2 2A 52 4 15S.51 15 2A 52 4 15S -.62 11 2A 52 5 15S.4 15 2A 52 6 15S -.5 13 Attachment L-22-211 Page 20 of 89

SG Row Tube TSP INCH %TW 2A 52 7 15S 1 2A 52 1 16S -.63 11 2A 52 1 15S -. 7 2 2A 52 11 16S.34 11 2A 52 11 15S.42 2 2A 52 24 16S -.55 1 2A 52 15S.46 12 2A 52 124 16S -.11 2 2A 52 125 16S -.16 41 2A 53 1 16S 23 2A 53 5 15S -.57 16 2A 53 6 15S -.5 14 2A 53 7 15S.4 16 2A 53 16S -.6 2A 53 1 16S -.56 13 2A 53 1 15S -.5 15 2A 53 11 15S -.5 14 2A 53 12 16S -.57 14 2A 53 1 1 15S.41 15 2A 53 1 2 15S -.61 15 2A 53 11 15S.45 13 2A 53 11 15S -.57 17 2A 53 112 15S -. 7 24 2A 53 113 15S.36 16 2A 53 113 15S -.52 12 2A 53 117 15S.34 13 2A 53 117 15S -.5 2A 53 121 16S -.14 2 2A 53 123 16S -.6 15 2A 53 125 16S -.14 3 2A 53 126 16S -.14 37 2A 54 1 16S -. 33 2A 54 4 16S -.53 16 2A 54 5 15S 1 2A 54 7 16S -.5 11 2A 54 1 15S 16 2A 54 12 15S 1 2A 54 3 16S -.65 11 2A 54 1 15S -.65 13 2A 54 16S -.71 12 2A 54 113 15S -.5 12 2A 54 12 16S -.64 Attachment L-22-211 Page 21 of 89

SG Row Tube TSP INCH %TW 2A 54 122 16S.3 13 2A 54 125 16S -.6 16 2A 54 126 16S -.1 4 2A 54 127 16S -.14 35 2A 55 4 15S -.64 12 2A 55 6 15S -.5 14 2A 55 7 15S.44 1 2A 55 16S -.6 14 2A 55 4 16S -.67 12 2A 55 63 16S -.72 12 2A 55 5 15S -.61 1 2A 55 1 15S.43 11 2A 55 1 5 15S -.5 1 2A 55 1 6 16S -.66 12 2A 55 1 7 15S -. 5 14 2A 55 1 15S -.61 2A 55 111 15S -.5 14 2A 55 112 16S -.14 14 2A 55 11 15S -.61 2A 55 124 16S -.7 16 2A 55 125 16S -.14 32 2A 55 126 16S -.11 2 2A 56 1 16S -.71 13 2A 56 5 16S -.63 12 2A 56 5 15S 1 2A 56 15S.44 14 2A 56 25 15S -.6 16 2A 56 2 13S -.55 11 2A 56 114 15S -.54 15 2A 56 12 16S -.61 1 2A 56 122 15S -.5 1 2A 56 125 16S -. 2 17 2A 56 126 16S -.64 12 2A 57 6 15S -.57 16 2A 57 7 15S -.57 1 2A 57 15S.41 2 2A 57 15S -.62 12 2A 57 11 16S -.6 11 2A 57 12 15S.46 17 2A 57 13 15S -.57 11 2A 57 3 16S -.61 11 2A 57 45 16S.3 Attachment L-22-211 Page 22 of 89

SG Row Tube TSP INCH %TW 2A 57 4 13S -.56 2A 57 125 16S -.61 16 2A 57 126 16S -.16 26 2A 57 127 16S -.64 17 2A 57 12 16S -.14 3 2A 5 1 16S -.12 31 2A 5 4 15S.51 1 2A 5 5 16S -.65 17 2A 5 5 15S -.64 17 2A 5 6 15S.46 2 2A 5 7 15S -.5 1 2A 5 12 16S.31 13 2A 5 13 15S 15 2A 5 16 15S.43 15 2A 5 55 16S -. 12 2A 5 7 15S -.57 2A 5 111 15S -. 2 2 2A 5 112 15S -.57 1 2A 5 12 15S. 2 16 2A 5 122 16S -.11 1 2A 5 124 16S -.7 13 2A 5 126 16S -.64 15 2A 5 127 16S -.11 24 2A 5 12 16S -.11 37 2A 5 5 15S -.5 13 2A 5 15S 15 2A 5 1 15S.4 1 2A 5 23 16S -.64 1 2A 5 15S -.5 2 2A 5 1 2 16S -.66 11 2A 5 1 15S -.57 1 2A 5 114 15S -.61 11 2A 5 126 16S -.11 25 2A 5 127 16S -.61 16 2A 6 1 16S -.62 13 2A 6 4 15S.46 22 2A 6 5 15S 1 2A 6 7 15S -.57 14 2A 6 1 15S -. 7 21 2A 6 1 16S -.71 16 2A 6 12 15S 1 2A 6 13 15S -.57 12 Attachment L-22-211 Page 23 of 89

SG Row Tube TSP INCH %TW 2A 6 14 16S -.6 12 2A 6 45 16S -. 3 11 2A 6 3 15S -.5 1 2A 6 1 4 15S -. 1 2A 6 111 15S -.11 23 2A 6 112 15S.41 1 2A 6 112 15S -.5 23 2A 6 127 16S -.64 2A 6 12 16S -.11 16 2A 6 12 16S -. 26 2A 61 1 16S -. 31 2A 61 6 16S -.71 1 2A 61 6 15S -.5 13 2A 61 41 16S -.73 1 2A 61 6 15S.3 11 2A 61 6 15S -.5 13 2A 61 1 6 16S -.66 15 2A 61 1 15S -.5 1 2A 61 11 15S -. 7 16 2A 61 114 15S -.61 13 2A 61 121 15S -.61 12 2A 61 12 16S -.11 25 2A 62 3 16S -.63 16 2A 62 3 15S -.64 23 2A 62 5 16S -.75 13 2A 62 5 15S -.62 14 2A 62 12 13S -.57 2A 62 12 15S 2 2A 62 13 16S -.6 13 2A 62 2 16S -.65 11 2A 62 1 15S -.5 11 2A 62 11 15S -.5 16 2A 62 116 15S -. 7 22 2A 62 11 15S -.11 2 2A 62 125 16S -.14 25 2A 62 127 16S -.62 14 2A 62 12 16S -.11 25 2A 62 12 16S -.11 2 2A 63 1 16S.3 1 2A 63 1 16S -.71 2A 63 2 16S -.6 23 2A 63 3 16S.27 11 Attachment L-22-211 Page 24 of 89

SG Row Tube TSP INCH %TW 2A 63 3 16S -.55 12 2A 63 4 15S -.5 2 2A 63 4 16S -. 5 15 2A 63 5 15S.53 15 2A 63 5 15S -.64 12 2A 63 16S -.61 22 2A 63 15S -.56 2 2A 63 16 16S -.57 11 2A 63 33 13S -.57 2A 63 43 16S -.6 13 2A 63 44 16S.34 11 2A 63 113 15S -. 16 2A 63 115 15S -.61 16 2A 63 11 15S -. 1 2A 63 12 16S.41 13 2A 63 12 16S -.7 17 2A 63 12 15S.43 14 2A 63 12 15S -.5 16 2A 63 121 15S -.5 14 2A 63 122 16S -.11 25 2A 63 125 16S -.16 3 2A 63 127 16S -.64 11 2A 63 12 16S -.11 2 2A 63 12 16S -.11 23 2A 63 13 16S -. 27 2A 64 1 16S -.11 25 2A 64 2 16S.45 12 2A 64 2 16S -.73 16 2A 64 3 16S.4 14 2A 64 4 16S.4 15 2A 64 4 16S -.6 12 2A 64 4 15S -.64 21 2A 64 15S.51 11 2A 64 11 15S -.61 11 2A 64 13 16S -.7 15 2A 64 13 15S -.55 21 2A 64 44 16S -.72 11 2A 64 111 15S -.61 15 2A 64 113 15S -.5 14 2A 64 114 15S.34 16 2A 64 12 16S -.11 2 2A 64 12 16S -.11 1 Attachment L-22-211 Page 25 of 89

SG Row Tube TSP INCH %TW 2A 64 13 16S -.11 1 2A 65 3 15S -.57 1 2A 65 4 16S.4 1 2A 65 4 16S -.65 12 2A 65 4 15S -.62 17 2A 65 6 15S.4 17 2A 65 6 15S -.5 2A 65 7 15S -.5 11 2A 65 16S -.61 13 2A 65 15S.52 12 2A 65 15S -.5 13 2A 65 1 15S.46 14 2A 65 11 15S 21 2A 65 12 16S -.6 13 2A 65 13 16S 14 2A 65 36 16S.36 1 2A 65 45 16S -.74 15 2A 65 55 16S -.7 1 2A 65 1 7 15S -.1 13 2A 65 1 15S.32 1 2A 65 1 15S -.5 21 2A 65 111 15S -.11 2 2A 65 113 15S.41 16 2A 65 114 15S.34 2 2A 65 114 15S -.5 23 2A 65 115 16S -.6 13 2A 65 115 15S -.5 13 2A 65 121 16S.43 12 2A 65 121 16S -.6 17 2A 65 124 16S -.11 2 2A 65 12 16S -.57 14 2A 65 12 16S -. 26 2A 65 13 16S -.11 31 2A 65 13 13S.4 14 2A 66 1 16S -.14 3 2A 66 4 15S.4 22 2A 66 4 15S -.64 1 2A 66 6 15S -.57 14 2A 66 1 16S -.57 16 2A 66 11 15S.51 17 2A 66 32 13S -.52 1 2A 66 3 13S -.61 7 Attachment L-22-211 Page 26 of 89

SG Row Tube TSP INCH %TW 2A 66 46 16S.4 13 2A 66 46 16S -.7 2A 66 11 15S -.61 11 2A 66 112 15S.43 15 2A 66 114 15S.3 13 2A 66 121 16S -.11 16 2A 66 124 16S -. 22 2A 66 127 16S -. 25 2A 66 12 16S -.11 1 2A 66 13 16S -.11 25 2A 66 13 11S.55 23 2A 66 131 16S -.11 41 2A 66 131 13S -.43 11 2A 67 4 15S.56 1 2A 67 6 15S -.57 1 2A 67 16S -.55 15 2A 67 15S -.61 1 2A 67 11 16S -.52 15 2A 67 12 16S -.11 21 2A 67 2 16S -.6 14 2A 67 22 16S -.6 13 2A 67 37 16S.43 13 2A 67 44 16S.41 11 2A 67 4 15S -. 1 2A 67 1 16S -.63 13 2A 67 1 15S.41 14 2A 67 11 15S -.61 21 2A 67 123 16S -.11 27 2A 67 127 16S.3 14 2A 67 12 16S -.11 16 2A 67 12 16S -.11 37 2A 67 13 16S -. 5 23 2A 6 1 14S -.55 7 2A 6 1 16S 17 2A 6 4 16S 1 2A 6 4 15S 23 2A 6 5 15S 1 2A 6 6 16S.36 16 2A 6 6 15S -.56 12 2A 6 16S -.6 16 2A 6 15S -.5 13 2A 6 1 16S -.6 14 Attachment L-22-211 Page 27 of 89

SG Row Tube TSP INCH %TW 2A 6 15 16S -.66 12 2A 6 1 16S -.55 11 2A 6 23 16S -.72 1 2A 6 24 16S -.77 13 2A 6 25 16S -.6 13 2A 6 45 16S.36 13 2A 6 46 16S -.67 13 2A 6 1 6 15S -.61 11 2A 6 1 15S.45 16 2A 6 113 15S -.61 2A 6 113 15S.41 1 2A 6 126 16S -.65 17 2A 6 12 16S -.11 1 2A 6 12 16S -.61 1 2A 6 13 16S -.11 33 2A 6 1 14S -.57 1 2A 6 1 16S 34 2A 6 2 16S -.6 15 2A 6 2 14S -.52 1 2A 6 3 16S -.71 13 2A 6 4 16S -.65 16 2A 6 5 15S -.5 17 2A 6 6 15S -.61 13 2A 6 1 15S -.61 17 2A 6 12 16S.31 14 2A 6 12 16S -.6 2 2A 6 14 16S -.6 15 2A 6 23 16S -.72 17 2A 6 24 16S.4 14 2A 6 2 16S.36 11 2A 6 36 13S -.54 11 2A 6 41 16S -.7 13 2A 6 116 15S -.61 11 2A 6 117 15S.45 2 2A 6 12 16S -.64 11 2A 6 12 16S -.61 15 2A 6 13 16S -.14 4 2A 6 131 16S -.11 2 2A 6 132 13S -.36 2A 7 3 16S -.14 2 2A 7 3 15S -. 5 31 2A 7 7 15S -.5 Attachment L-22-211 Page 28 of 89

SG Row Tube TSP INCH %TW 2A 7 7 16S.45 13 2A 7 15S -.61 15 2A 7 13 16S -.55 13 2A 7 23 16S -.72 1 2A 7 35 16S -.62 16 2A 7 47 16S.43 13 2A 7 51 16S -. 5 2A 7 4 15S -.7 6 2A 7 113 15S.43 21 2A 7 113 15S -.61 12 2A 7 114 15S.45 12 2A 7 116 15S.41 15 2A 7 122 16S -.11 17 2A 7 126 16S -.63 14 2A 7 12 16S -.5 13 2A 7 12 16S -.14 41 2A 7 13 16S -.11 2 2A 7 131 16S -.11 2 2A 71 1 16S -.14 2 2A 71 1 14S 26 2A 71 2 14S -.5 14 2A 71 2 16S 1 2A 71 4 15S.53 1 2A 71 4 15S -.64 16 2A 71 4 16S.4 14 2A 71 5 15S -.5 17 2A 71 6 16S -.6 14 2A 71 6 15S -.57 11 2A 71 7 16S -.6 15 2A 71 7 15S -.57 21 2A 71 14 16S -.5 16 2A 71 14 15S -.5 2 2A 71 1 15S -.62 2A 71 24 16S -.75 2 2A 71 25 16S -.63 12 2A 71 45 16S -. 3 1 2A 71 47 16S.47 13 2A 71 7 15S -.61 13 2A 71 116 16S -.66 13 2A 71 126 16S -.6 12 2A 71 127 16S -.6 15 2A 71 12 16S -.5 14 Attachment L-22-211 Page 29 of 89

SG Row Tube TSP INCH %TW 2A 71 12 16S -.61 14 2A 71 131 16S -.11 24 2A 72 3 15S -.64 16 2A 72 4 16S -.7 14 2A 72 4 15S -.5 17 2A 72 16S 23 2A 72 1 16S -.61 13 2A 72 13 16S -.57 14 2A 72 2 16S -.55 11 2A 72 24 15S -.57 17 2A 72 2 16S -.62 12 2A 72 34 16S.36 1 2A 72 41 13S -.45 11 2A 72 4 16S -.7 14 2A 72 1 15S.43 15 2A 72 1 15S -.61 1 2A 72 1 15S.45 13 2A 72 114 15S.41 16 2A 72 114 15S -.61 13 2A 72 121 16S -.61 7 2A 72 12 16S -.14 33 2A 72 12 16S.34 31 2A 72 12 16S -.7 34 2A 72 13 16S -.7 27 2A 72 131 16S -.11 2 2A 73 1 16S -.16 26 2A 73 1 14S -.5 17 2A 73 1 13S 12 2A 73 2 14S -.5 13 2A 73 3 16S.36 12 2A 73 3 16S -.62 1 2A 73 3 15S -.67 24 2A 73 4 15S -.62 13 2A 73 4 16S 16 2A 73 5 15S -.5 17 2A 73 6 15S -.5 11 2A 73 16S -.7 14 2A 73 24 16S -.73 14 2A 73 26 16S -.5 14 2A 73 2 16S -.55 13 2A 73 3 16S.3 12 2A 73 41 16S -.67 13 Attachment L-22-211 Page 30 of 89

SG Row Tube TSP INCH %TW 2A 73 46 16S -.7 13 2A 73 1 2 15S -.16 13 2A 73 1 15S -.61 21 2A 73 113 15S -.61 7 2A 73 115 15S.3 16 2A 73 115 15S -.5 16 2A 73 12 15S.43 22 2A 73 127 16S -.61 16 2A 73 12 16S -.63 13 2A 73 12 16S -.11 32 2A 73 13 16S -.6 17 2A 73 13 16S.45 12 2A 73 131 16S -.64 2 2A 74 1 14S -.57 11 2A 74 3 15S.4 14 2A 74 3 15S -.5 16 2A 74 6 15S.46 12 2A 74 15S -.55 1 2A 74 15S -.5 15 2A 74 11 16S -.53 11 2A 74 11 15S -.5 13 2A 74 12 16S -.57 12 2A 74 12 15S -.61 15 2A 74 2 16S -.57 14 2A 74 32 16S.3 12 2A 74 32 13S -.53 14 2A 74 42 16S.2 12 2A 74 4 16S -. 7 11 2A 74 55 16S.4 12 2A 74 6 15S.37 15 2A 74 6 15S -.64 17 2A 74 1 2 15S -.64 2A 74 11 16S -.63 11 2A 74 112 15S.43 14 2A 74 117 15S -.61 14 2A 74 127 16S -.61 12 2A 74 12 16S -.11 2 2A 74 12 16S -.63 26 2A 74 13 16S -.11 3 2A 74 131 13S -.55 6 2A 74 131 16S -.11 3 2A 75 1 16S -.11 24 Attachment L-22-211 Page 31 of 89

SG Row Tube TSP INCH %TW 2A 75 1 14S -.55 11 2A 75 2 14S -.55 13 2A 75 3 16S.45 1 2A 75 3 15S 22 2A 75 4 15S 1 2A 75 5 16S.5 1 2A 75 5 15S -.57 15 2A 75 6 16S.47 14 2A 75 7 15S 1 2A 75 15S -.57 17 2A 75 12 16S -.5 12 2A 75 12 15S -.57 23 2A 75 27 16S -.74 1 2A 75 2 15S -.65 2A 75 33 16S.43 12 2A 75 42 16S.31 13 2A 75 45 16S.45 1 2A 75 47 16S.4 12 2A 75 4 16S.43 12 2A 75 1 4 15S.43 13 2A 75 1 4 15S -.62 16 2A 75 1 5 16S -.64 12 2A 75 1 15S -.62 1 2A 75 11 15S -.11 13 2A 75 12 16S -.66 13 2A 75 121 15S.43 1 2A 75 123 16S -.61 12 2A 75 124 16S -.16 1 2A 75 127 16S -.7 11 2A 75 12 16S -. 34 2A 75 13 16S -. 26 2A 75 131 16S -.57 1 2A 75 131 11S.57 2 2A 76 3 15S -.5 25 2A 76 35 16S -.67 12 2A 76 4 14S -.7 11 2A 76 1 7 15S.43 12 2A 76 12 16S -.57 13 2A 76 123 16S -. 7 1 2A 76 124 16S -.66 25 2A 76 126 16S -.5 17 2A 76 127 16S -.14 3 Attachment L-22-211 Page 32 of 89

SG Row Tube TSP INCH %TW 2A 76 12 16S -.14 3 2A 76 13 16S.3 22 2A 76 13 16S -.61 25 2A 77 1 16S.53 24 2A 77 1 14S.4 1 2A 77 1 14S -.5 21 2A 77 2 14S.4 13 2A 77 2 14S -.55 17 2A 77 2 13S -.5 2A 77 3 15S -.64 14 2A 77 4 14S -.53 11 2A 77 4 16S 13 2A 77 5 15S.46 22 2A 77 111 15S.36 16 2A 77 111 15S -.61 6 2A 77 11 15S -.5 15 2A 77 124 16S -.6 14 2A 77 125 16S -.66 1 2A 77 127 16S -.6 24 2A 77 127 16S.47 14 2A 77 12 16S.37 26 2A 77 12 16S -.45 36 2A 77 13 16S -.61 22 2A 77 131 16S -.57 24 2A 7 1 16S.53 21 2A 7 1 14S.5 16 2A 7 1 14S -.52 3 2A 7 1 13S.52 13 2A 7 2 16S.3 16 2A 7 3 16S.3 16 2A 7 5 15S -.45 11 2A 7 6 15S -. 5 2 2A 7 2 16S -.62 2A 7 43 16S -.64 2A 7 1 6 15S.46 12 2A 7 1 6 15S -.61 14 2A 7 116 15S.34 13 2A 7 121 15S -. 7 24 2A 7 122 16S -.7 14 2A 7 127 16S -. 26 2A 7 12 16S -. 26 2A 7 13 16S -.66 15 Attachment L-22-211 Page 33 of 89

SG Row Tube TSP INCH %TW 2A 7 131 16S -.43 34 2A 7 1 16S 34 2A 7 1 14S 25 2A 7 2 14S.5 12 2A 7 2 14S -.55 16 2A 7 3 15S.51 2 2A 7 3 16S 27 2A 7 7 16S -.6 11 2A 7 13 14S -.52 17 2A 7 1 15S.41 12 2A 7 115 15S.45 1 2A 7 117 15S -. 7 13 2A 7 122 16S -.14 2 2A 7 126 16S -.6 17 2A 7 12 16S -.6 16 2A 7 13 16S -.64 16 2A 7 131 16S -.6 24 2A 3 16S -.74 11 2A 45 16S -.71 11 2A 11 16S -.5 11 2A 114 15S -.62 13 2A 114 15S.43 13 2A 12 16S -.57 24 2A 131 16S -.11 37 2A 1 1 16S -.11 3 2A 1 15S -.54 1 2A 1 32 16S -.76 12 2A 1 46 16S -.7 13 2A 1 112 15S -.64 14 2A 1 115 15S -.62 12 2A 1 116 16S -.61 1 2A 1 12 16S -.5 16 2A 1 13 16S -.57 1 2A 1 131 16S -.4 3 2A 2 1 14S -.55 1 2A 2 2 16S -.11 17 2A 2 6 14S 23 2A 2 1 16S -.55 13 2A 2 1 7 15S.41 17 2A 2 1 7 15S -.5 21 2A 2 114 15S -.5 2A 2 115 16S -.61 14 Attachment L-22-211 Page 34 of 89

SG Row Tube TSP INCH %TW 2A 2 12 16S -.61 1 2A 2 121 15S -. 17 2A 2 124 16S -.57 14 2A 2 127 16S -.61 13 2A 2 12 16S -.5 1 2A 2 12 16S -. 31 2A 2 131 16S -.61 14 2A 3 1 13S.53 13 2A 3 1 14S -. 2 3 2A 3 6 14S 24 2A 3 115 15S -.5 14 2A 3 121 15S -.57 15 2A 3 122 16S -.61 11 2A 3 122 15S.41 16 2A 3 127 16S -.57 1 2A 3 12 16S -.61 11 2A 3 131 16S -. 7 33 2A 3 132 13S -.36 12 2A 3 132 11S -.34 2A 4 1 16S -.11 36 2A 4 1 14S.5 13 2A 4 1 14S -.52 15 2A 4 3 15S -.61 13 2A 4 32 16S -.67 16 2A 4 45 16S -.65 14 2A 4 1 3 15S -.5 2A 4 1 6 15S.37 15 2A 4 1 6 15S -.55 16 2A 4 114 15S -.57 14 2A 4 11 15S.41 15 2A 4 11 15S -.57 13 2A 4 124 16S -.57 15 2A 4 126 16S.2 21 2A 4 127 16S -.11 2 2A 4 13 16S -.61 11 2A 4 131 16S -.55 3 2A 5 2 14S -.52 14 2A 5 7 16S -.5 15 2A 5 33 16S -.71 2A 5 1 6 16S -.5 11 2A 5 1 6 15S -.57 1 2A 5 123 16S -.11 24 Attachment L-22-211 Page 35 of 89

SG Row Tube TSP INCH %TW 2A 5 12 16S -.61 2 2A 5 12 16S -.55 23 2A 5 13 16S -.55 17 2A 6 2 14S 1 2A 6 6 14S -.52 11 2A 6 7 16S -.45 12 2A 6 16S -.5 2A 6 2 16S -.74 13 2A 6 2 14S -.57 14 2A 6 43 16S -.7 14 2A 6 5 15S -.5 1 2A 6 114 15S.45 13 2A 6 12 16S -.5 12 2A 6 121 16S -.11 24 2A 6 122 16S -.14 23 2A 6 123 16S -.14 2 2A 6 125 16S -.57 14 2A 6 126 16S -.63 13 2A 6 127 16S -. 24 2A 6 12 16S -.11 21 2A 6 12 16S -.11 34 2A 6 13 16S -.5 21 2A 6 131 16S -.41 32 2A 7 6 15S -.5 2A 7 3 14S -.52 15 2A 7 34 16S -.73 14 2A 7 1 6 15S -.5 15 2A 7 12 16S -.5 21 2A 7 122 16S -.11 16 2A 7 124 16S -. 21 2A 7 126 16S -.61 1 2A 7 12 16S -.55 12 2A 7 12 16S -.46 27 2A 7 13 16S -.14 35 2A 1 16S -.11 33 2A 1 14S -.52 1 2A 2 14S.5 12 2A 2 14S -.55 16 2A 4 14S -.55 12 2A 1 16S -.63 11 2A 41 16S -.6 13 2A 41 13S -.54 13 Attachment L-22-211 Page 36 of 89

SG Row Tube TSP INCH %TW 2A 4 16S -.72 1 2A 54 16S -.74 1 2A 55 16S -.77 12 2A 1 7 15S -.64 12 2A 113 15S -.61 2A 116 15S -.5 2A 121 16S -.66 14 2A 126 16S -.55 15 2A 127 16S.3 25 2A 127 16S -.5 31 2A 12 16S -.5 1 2A 13 16S -.5 16 2A 4 15S -.57 14 2A 1 14S.3 1 2A 21 16S -.71 2A 42 16S -.6 16 2A 5 16S.31 12 2A 1 16S -.16 16 2A 1 15S -.64 12 2A 113 15S -. 7 12 2A 11 15S -.5 16 2A 121 16S -.65 11 2A 123 16S -.55 16 2A 126 16S -. 3 2A 127 16S.32 23 2A 127 16S -.5 2 2A 12 16S -.5 21 2A 13 16S. 2 36 2A 1 14S -.52 12 2A 3 14S -.57 12 2A 16S -.5 2A 1 16S -.7 1 2A 26 16S -.5 2A 7 16S -. 4 15 2A 1 15S -.64 14 2A 114 15S -.5 1 2A 115 16S.36 15 2A 121 16S -.5 14 2A 125 16S -.63 14 2A 126 16S.34 15 2A 126 16S -.57 23 2A 127 16S -.5 26 Attachment L-22-211 Page 37 of 89

SG Row Tube TSP INCH %TW 2A 12 16S -.52 25 2A 12 16S.26 22 2A 12 16S -.61 32 2A 1 1 14S -.53 1 2A 1 2 14S -.52 17 2A 1 3 14S -.56 17 2A 1 4 16S -. 15 2A 1 1 16S -.7 2A 1 1 15S -.55 12 2A 1 21 16S -.62 11 2A 1 24 16S -.72 1 2A 1 27 16S.36 11 2A 1 3 16S -.6 13 2A 1 42 16S.2 2A 1 16S -.5 13 2A 1 1 16S -.61 1 2A 1 113 15S -. 17 2A 1 115 16S -.63 15 2A 1 116 16S -.6 16 2A 1 117 15S.44 14 2A 1 122 16S -.12 34 2A 1 123 16S -.61 22 2A 1 124 16S -.57 21 2A 1 125 16S -.5 15 2A 1 127 16S -.61 17 2A 1 12 16S -.61 34 2A 1 12 16S.41 17 2A 1 12 16S -.57 23 2A 2 1 16S -.11 33 2A 2 35 16S -.7 13 2A 2 3 16S -.6 14 2A 2 4 16S -.65 13 2A 2 42 16S -.71 13 2A 2 44 13S -.4 13 2A 2 1 16S -.56 12 2A 2 3 14S.47 2A 2 1 5 15S -.5 15 2A 2 1 6 15S -.6 13 2A 2 1 7 15S -.62 13 2A 2 122 16S -.12 23 2A 2 124 16S -.5 14 2A 2 125 16S -. 7 24 Attachment L-22-211 Page 38 of 89

SG Row Tube TSP INCH %TW 2A 2 12 16S -.4 31 2A 2 12 16S -. 7 34 2A 3 1 14S -.53 17 2A 3 15S.4 14 2A 3 16 16S -.52 1 2A 3 37 13S -.52 11 2A 3 41 16S.27 11 2A 3 43 16S -.71 11 2A 3 1 2 16S -.6 16 2A 3 1 5 16S.31 13 2A 3 12 16S -.5 15 2A 3 123 16S -.61 11 2A 3 124 16S -.5 16 2A 3 125 16S -.5 13 2A 3 126 16S -.5 1 2A 3 12 16S -.53 2A 4 1 14S -.6 2A 4 6 15S -. 7 17 2A 4 14 16S -.5 2A 4 1 16S -.62 11 2A 4 2 16S -.7 1 2A 4 21 14S -.57 13 2A 4 26 16S -.65 14 2A 4 27 16S -.72 12 2A 4 37 16S -.7 1 2A 4 43 16S -.71 15 2A 4 1 16S -.6 14 2A 4 3 16S -.67 14 2A 4 1 3 15S -.57 2 2A 4 1 5 15S -.63 6 2A 4 116 16S -.5 14 2A 4 122 16S -.63 1 2A 4 123 16S -.6 17 2A 4 124 16S -.62 12 2A 4 126 16S -.56 1 2A 4 127 16S -.5 2 2A 4 12 16S -.56 21 2A 5 1 16S -. 7 3 2A 5 1 14S -.57 1 2A 5 2 14S -.6 12 2A 5 16 16S -.6 1 2A 5 1 16S -.53 12 Attachment L-22-211 Page 39 of 89

SG Row Tube TSP INCH %TW 2A 5 2 16S -.5 1 2A 5 32 16S -.71 13 2A 5 3 16S -.61 16 2A 5 4 16S -.6 23 2A 5 5 16S -.73 15 2A 5 3 16S -.6 16 2A 5 6 15S -.62 14 2A 5 1 5 15S.36 14 2A 5 11 16S.31 12 2A 5 11 16S -.5 14 2A 5 114 15S -.11 1 2A 5 121 16S -.6 13 2A 5 125 16S -.5 14 2A 5 126 16S -.16 2 2A 5 127 16S.2 15 2A 5 127 16S -.44 24 2A 6 3 14S -.56 11 2A 6 15 16S -.7 2A 6 1 16S -.6 14 2A 6 2 16S -.11 14 2A 6 2 14S -.54 11 2A 6 3 16S -.14 17 2A 6 1 3 15S.36 11 2A 6 1 4 15S -.64 16 2A 6 11 15S -.5 1 2A 6 11 16S -.12 26 2A 6 12 16S -.5 14 2A 6 124 16S -. 25 2A 6 125 16S -.56 27 2A 6 126 16S -.5 13 2A 6 127 16S -. 7 34 2A 7 4 15S -. 7 17 2A 7 2 16S -.71 15 2A 7 3 14S -.55 15 2A 7 33 16S -.76 12 2A 7 41 14S -.61 13 2A 7 4 16S -.52 1 2A 7 1 16S -.61 12 2A 7 112 15S 15 2A 7 114 16S -.5 1 2A 7 12 16S -.6 11 2A 7 124 16S -.55 15 Attachment L-22-211 Page 40 of 89

SG Row Tube TSP INCH %TW 2A 7 126 16S -.12 3 2A 1 14S -.55 1 2A 15S.42 12 2A 15 16S -.57 13 2A 24 16S -.6 2A 2 16S -.62 17 2A 4 16S -.6 11 2A 4 16S 14 2A 7 16S -.57 12 2A 1 15S.3 14 2A 1 1 15S -.6 12 2A 1 6 16S.24 11 2A 1 15S -.64 1 2A 112 16S -.57 11 2A 112 15S -.5 12 2A 113 16S -.6 15 2A 122 16S -.5 16 2A 123 16S -.56 1 2A 124 16S -. 34 2A 125 16S -.5 22 2A 126 16S -.56 17 2A 2 14S -.57 16 2A 42 16S -.64 21 2A 4 16S -.73 12 2A 3 16S -.57 15 2A 112 16S -.54 12 2A 115 15S -.5 2A 12 16S -.5 12 2A 122 16S -.55 1 2A 123 16S -.56 11 2A 124 16S -.56 26 2A 125 16S -.53 23 2A 1 1 16S -. 25 2A 1 2 14S -.62 1 2A 1 5 15S.45 13 2A 1 13 14S -.52 14 2A 1 27 16S -.5 12 2A 1 2 16S -.64 13 2A 1 34 16S -.63 21 2A 1 3 16S -.4 21 2A 1 61 11S -.65 7 2A 1 1 4 15S -.6 11 Attachment L-22-211 Page 41 of 89

SG Row Tube TSP INCH %TW 2A 1 111 16S -.57 11 2A 1 123 16S -.56 15 2A 1 124 16S -.57 13 2A 1 125 16S -. 21 2A 1 1 7 15S -.56 12 2A 1 1 16 14S -.55 14 2A 1 1 36 16S -.63 15 2A 1 1 3 16S -.63 17 2A 1 1 61 16S -. 14 2A 1 1 62 16S -.67 13 2A 1 1 15S.43 1 2A 1 1 1 15S.43 11 2A 1 1 4 15S -.64 11 2A 1 1 11 16S -.57 1 2A 1 1 122 16S -.57 2 2A 1 1 123 16S -.5 25 2A 1 1 124 16S.2 1 2A 1 1 124 16S -.54 27 2A 1 2 2 14S -.57 1 2A 1 2 41 16S -.14 17 2A 1 2 56 16S -.6 17 2A 1 2 76 15S.3 1 2A 1 2 7 15S -.62 2A 1 2 15S -.63 2 2A 1 2 1 15S.34 17 2A 1 2 1 15S -.63 17 2A 1 2 115 16S -.73 1 2A 1 2 11 16S -.11 22 2A 1 2 122 16S -.56 1 2A 1 3 1 14S -.55 15 2A 1 3 2 14S -.57 17 2A 1 3 5 15S -.61 1 2A 1 3 36 16S -.6 13 2A 1 3 44 16S.13 14 2A 1 3 52 16S -.74 13 2A 1 3 62 16S -.76 16 2A 1 3 116 15S.51 12 2A 1 3 11 16S -.6 13 2A 1 3 11 16S -.12 1 2A 1 3 12 16S -.12 1 2A 1 3 122 16S -.6 12 2A 1 3 123 16S -.14 15 Attachment L-22-211 Page 42 of 89

SG Row Tube TSP INCH %TW 2A 1 4 1 14S -.55 12 2A 1 4 2 14S -.5 13 2A 1 4 4 14S -.55 13 2A 1 4 5 15S -.52 17 2A 1 4 31 16S -.76 16 2A 1 4 41 16S -.7 11 2A 1 4 45 16S -.74 1 2A 1 4 46 16S -.71 13 2A 1 4 47 16S -.65 13 2A 1 4 5 16S -.73 14 2A 1 4 52 16S -.67 12 2A 1 4 56 16S -.54 14 2A 1 4 6 16S -.7 17 2A 1 4 5 15S -.61 14 2A 1 4 16S.31 13 2A 1 4 15S -.61 22 2A 1 4 6 15S -. 5 14 2A 1 4 7 16S -.5 13 2A 1 4 15S.41 16 2A 1 4 1 15S -.62 13 2A 1 4 1 2 15S.3 12 2A 1 4 11 16S.26 11 2A 1 4 12 16S -.57 2A 1 4 121 16S -.11 23 2A 1 4 122 16S -.5 1 2A 1 4 123 16S 33 2A 1 5 35 16S -.63 13 2A 1 5 37 16S -.65 15 2A 1 5 44 16S -.72 1 2A 1 5 4 16S -.6 15 2A 1 5 52 16S -.7 16 2A 1 5 55 16S -.71 12 2A 1 5 57 16S.4 11 2A 1 5 6 16S -.76 14 2A 1 5 15S.34 12 2A 1 5 15S -.5 1 2A 1 5 6 15S 1 2A 1 5 15S.3 14 2A 1 5 15S -.6 13 2A 1 5 11 16S.33 2A 1 5 11 16S -.57 23 2A 1 5 12 16S -.43 16 Attachment L-22-211 Page 43 of 89

SG Row Tube TSP INCH %TW 2A 1 5 121 16S -.41 2 2A 1 5 122 16S -.14 3 2A 1 6 34 16S -.64 13 2A 1 6 35 16S -.64 11 2A 1 6 4 S. 5 12 2A 1 6 41 16S -.72 1 2A 1 6 42 16S -.52 15 2A 1 6 43 16S -.14 15 2A 1 6 46 16S -.4 1 2A 1 6 55 16S -.76 2A 1 6 7 15S -.65 12 2A 1 6 5 15S -.7 6 2A 1 6 1 1 15S -.55 12 2A 1 6 1 3 15S -.62 12 2A 1 6 111 16S -.55 13 2A 1 6 116 16S -.55 11 2A 1 6 11 16S -.55 15 2A 1 6 12 16S -. 25 2A 1 6 121 16S -.11 34 2A 1 7 1 14S -.6 11 2A 1 7 22 16S -.62 13 2A 1 7 37 16S -.6 1 2A 1 7 3 16S -.72 12 2A 1 7 43 16S -.6 13 2A 1 7 46 16S -.5 12 2A 1 7 4 16S -.4 14 2A 1 7 5 16S -.72 1 2A 1 7 51 16S -.71 1 2A 1 7 51 14S -.5 22 2A 1 7 74 15S -.63 11 2A 1 7 7 15S -.63 14 2A 1 7 3 15S -.61 1 2A 1 7 5 15S.3 12 2A 1 7 7 15S -.57 11 2A 1 7 15S -.5 1 2A 1 7 4 15S -.56 13 2A 1 7 5 15S.3 12 2A 1 7 1 1 15S 14 2A 1 7 114 16S -.55 11 2A 1 7 115 16S -.57 16 2A 1 7 11 16S -.55 25 2A 1 7 12 16S -. 7 31 Attachment L-22-211 Page 44 of 89

SG Row Tube TSP INCH %TW 2A 1 31 16S -.67 12 2A 1 4 16S -.67 14 2A 1 41 16S -.6 15 2A 1 44 16S -.75 15 2A 1 46 16S -.65 1 2A 1 47 16S -.65 13 2A 1 4 16S -.73 16 2A 1 51 16S -.7 1 2A 1 53 16S -.54 1 2A 1 56 16S -.7 2A 1 5 16S -. 2 13 2A 1 7 15S -.5 14 2A 1 5 15S.4 13 2A 1 6 15S.36 13 2A 1 15S 14 2A 1 113 16S -.55 13 2A 1 11 16S -. 7 22 2A 1 11 16S -. 7 31 2A 1 4 14S -.55 1 2A 1 21 16S -.61 13 2A 1 31 16S -.61 11 2A 1 4 16S -.56 13 2A 1 41 16S -.6 2 2A 1 42 16S -.73 17 2A 1 44 16S -.7 1 2A 1 47 16S -.67 14 2A 1 51 16S -.65 16 2A 1 52 16S -.65 17 2A 1 55 16S.45 1 2A 1 55 16S -.77 17 2A 1 5 16S -.75 14 2A 1 16S -.54 1 2A 1 15S -.57 2A 1 4 15S.41 12 2A 1 4 15S -.57 13 2A 1 117 16S -.55 13 2A 11 2 16S -.7 16 2A 11 31 16S -.63 15 2A 11 36 14S -.57 14 2A 11 37 16S -.47 13 2A 11 37 14S -.5 15 2A 11 4 16S -.73 1 Attachment L-22-211 Page 45 of 89

SG Row Tube TSP INCH %TW 2A 11 43 16S -.71 21 2A 11 46 16S -.71 17 2A 11 47 16S -.65 14 2A 11 4 16S -.7 12 2A 11 51 16S -.67 1 2A 11 54 16S -.73 13 2A 11 5 15S -.64 15 2A 11 6 15S.43 12 2A 11 6 15S -.66 13 2A 11 7 15S -.61 15 2A 11 112 16S -.55 14 2A 11 114 16S -.57 15 2A 11 116 16S -.55 15 2A 11 117 16S -. 2 2A 111 4 15S -.54 11 2A 111 2 16S -.65 13 2A 111 31 16S -.64 11 2A 111 36 14S -.57 14 2A 111 3 16S -.56 1 2A 111 41 16S -.54 2 2A 111 42 16S -.6 14 2A 111 43 16S -.65 1 2A 111 45 16S -.6 1 2A 111 4 16S -.73 14 2A 111 52 16S -.5 25 2A 111 53 16S -.77 13 2A 111 57 16S -.76 11 2A 111 73 15S -.61 11 2A 111 2 15S.43 12 2A 111 7 15S -.67 11 2A 111 3 15S.41 16 2A 111 113 16S -.11 2 2A 111 114 16S -. 1 2A 111 115 16S -.55 1 2A 112 1 14S -. 5 26 2A 112 5 14S -.55 1 2A 112 6 14S -.53 13 2A 112 7 15S.44 13 2A 112 37 16S -.6 14 2A 112 3 16S -.6 14 2A 112 4 16S -.66 1 2A 112 43 16S -.7 11 Attachment L-22-211 Page 46 of 89

SG Row Tube TSP INCH %TW 2A 112 44 16S -.6 17 2A 112 5 16S -.16 21 2A 112 51 16S -.6 13 2A 112 54 16S -.72 16 2A 112 1 15S.41 12 2A 112 2 15S -.64 13 2A 112 4 15S -.14 15 2A 112 4 15S 2 2A 112 112 15S.41 17 2A 112 113 16S -. 23 2A 112 114 16S -.54 22 2A 112 115 16S -.52 22 2A 112 116 16S -.5 17 2A 113 6 14S -.54 12 2A 113 7 14S -.54 11 2A 113 14S -.5 11 2A 113 2 16S -.63 13 2A 113 3 16S -.65 11 2A 113 31 16S -.67 15 2A 113 4 16S -.47 1 2A 113 41 16S -.73 27 2A 113 43 16S -.65 17 2A 113 44 16S -.66 1 2A 113 46 16S -.66 13 2A 113 47 16S -.67 17 2A 113 51 16S -.71 12 2A 113 52 16S -.71 1 2A 113 55 16S -.72 11 2A 113 5 16S -.71 2A 113 67 16S -.63 11 2A 113 3 15S -.11 1 2A 113 6 16S.34 12 2A 113 15S.32 2A 113 15S.43 14 2A 113 2 15S -.5 12 2A 113 114 16S -.55 1 2A 113 115 16S -.52 15 2A 114 6 15S -.55 13 2A 114 2 16S -.65 16 2A 114 3 16S -.67 13 2A 114 32 16S -.66 11 2A 114 3 16S -.6 14 Attachment L-22-211 Page 47 of 89

SG Row Tube TSP INCH %TW 2A 114 3 16S -.72 15 2A 114 41 16S -.67 2 2A 114 44 16S -.65 11 2A 114 45 16S -.71 14 2A 114 4 16S -.72 1 2A 114 53 16S -.72 17 2A 114 54 16S -.71 14 2A 114 7 15S -.62 24 2A 114 15S -.6 13 2A 114 2 15S -.63 14 2A 114 115 16S -.5 25 2A 115 1 14S -.55 13 2A 115 2 16S -.6 24 2A 115 32 16S -.6 14 2A 115 37 16S -.64 16 2A 115 3 16S -.65 15 2A 115 4 16S -.72 11 2A 115 42 16S -.67 14 2A 115 44 16S -.6 16 2A 115 47 16S -.67 13 2A 115 4 16S -.7 15 2A 115 4 16S -.71 1 2A 115 1 15S -.11 22 2A 115 6 15S -.54 14 2A 115 1 15S -.64 14 2A 115 7 16S -. 15 2A 115 1 16S -.54 12 2A 115 114 16S -.11 3 2A 116 1 16S -.11 21 2A 116 1 14S -.57 12 2A 116 14S -.5 1 2A 116 27 16S -.63 12 2A 116 2 16S -.61 16 2A 116 31 16S -.65 16 2A 116 32 16S -.14 16 2A 116 36 16S -.7 12 2A 116 37 16S -.6 14 2A 116 3 16S -.56 2 2A 116 4 16S -.65 14 2A 116 42 16S -.6 17 2A 116 43 16S -.66 22 2A 116 45 14S -.56 14 Attachment L-22-211 Page 48 of 89

SG Row Tube TSP INCH %TW 2A 116 4 16S -.61 23 2A 116 4 16S -.63 14 2A 116 51 16S -.6 21 2A 116 63 15S -.66 2A 116 15S.4 11 2A 116 11 16S -.61 2 2A 116 111 16S -.11 2 2A 116 112 16S -.11 21 2A 117 1 14S -.54 1 2A 117 2 16S -.6 13 2A 117 22 16S -.63 13 2A 117 2 16S -.63 2A 117 31 16S -.63 12 2A 117 32 16S -.5 13 2A 117 33 16S -.54 15 2A 117 36 16S -.63 1 2A 117 3 16S -.7 14 2A 117 3 16S -.7 16 2A 117 4 16S -.6 15 2A 117 41 16S -.57 14 2A 117 47 16S -.6 12 2A 117 4 13S -.54 1 2A 117 5 16S -.7 14 2A 117 51 16S -.76 15 2A 117 53 16S -.66 17 2A 117 55 16S -.73 15 2A 117 56 15S.34 1 2A 117 4 15S.42 14 2A 117 5 15S.32 12 2A 117 15S -. 7 2 2A 117 1 16S -.5 2 2A 11 1 14S -.54 12 2A 11 2 14S 12 2A 11 5 15S.46 14 2A 11 1 14S -.57 1 2A 11 35 16S -.66 14 2A 11 41 16S -.7 13 2A 11 43 16S -.54 1 2A 11 44 16S -.16 17 2A 11 45 16S -.7 17 2A 11 46 16S -.72 1 2A 11 77 15S -.56 15 Attachment L-22-211 Page 49 of 89

SG Row Tube TSP INCH %TW 2A 11 4 15S -.52 1 2A 11 15S -.62 12 2A 11 1 15S.3 2A 11 1 7 16S -.54 15 2A 11 1 16S -.5 16 2A 11 1 14S -.5 1 2A 11 21 16S -.63 12 2A 11 3 16S -.65 12 2A 11 31 16S -.51 23 2A 11 35 16S -.65 11 2A 11 37 16S -.64 16 2A 11 42 16S -.6 16 2A 11 43 16S.45 1 2A 11 44 16S -.71 13 2A 11 4 16S -.5 16 2A 11 73 15S.37 12 2A 11 77 15S -.56 12 2A 11 1 15S -.52 16 2A 11 2 15S -.57 1 2A 11 5 15S.4 13 2A 11 7 16S.4 2A 11 7 15S -.5 13 2A 11 15S.42 11 2A 11 15S -.55 12 2A 11 1 4 16S -.64 11 2A 11 1 6 16S 15 2A 12 1 16S.31 13 2A 12 1 16S -.63 1 2A 12 3 16S -.5 1 2A 12 31 16S -.47 1 2A 12 32 16S -.63 22 2A 12 42 16S -.6 1 2A 12 43 16S -.71 23 2A 12 44 16S.1 13 2A 12 45 16S -.74 14 2A 12 4 16S -.6 13 2A 12 4 16S -.73 12 2A 12 6 15S -.62 1 2A 12 7 15S -.5 11 2A 12 71 15S -.56 11 2A 12 74 15S.36 13 2A 12 4 15S -.53 14 Attachment L-22-211 Page 50 of 89

SG Row Tube TSP INCH %TW 2A 12 1 4 16S -.61 14 2A 12 1 6 16S -. 1 2A 121 1 14S -.52 12 2A 121 1 16S.4 15 2A 121 32 13S -.36 14 2A 121 37 16S -.71 13 2A 121 41 16S -.66 17 2A 121 43 16S -.65 2 2A 121 44 16S -.55 1 2A 121 45 16S -.6 1 2A 121 46 16S -.7 14 2A 121 51 16S -.72 15 2A 121 5 15S.4 14 2A 121 66 15S -. 16 2A 121 72 15S -.5 11 2A 121 75 15S -.5 1 2A 121 7 15S.4 14 2A 121 1 3 16S -.66 14 2A 121 1 4 16S -.61 14 2A 121 1 5 16S -.54 17 2A 121 1 6 16S -.55 16 2A 122 1 16S -.11 22 2A 122 42 16S -.72 15 2A 122 43 16S -.56 14 2A 122 45 16S -.52 17 2A 122 47 16S -.73 15 2A 122 4 16S -.55 14 2A 122 5 15S -. 14 2A 122 67 15S -.63 1 2A 122 71 15S -.57 11 2A 122 2 16S -.75 11 2A 122 2 15S -. 7 25 2A 122 4 15S.33 15 2A 122 1 16S -.6 1 2A 122 1 2 16S -.54 11 2A 122 1 3 16S -.64 14 2A 122 1 5 16S -. 31 2A 123 1 16S -. 3 2A 123 1 14S -. 7 23 2A 123 5 14S -.54 21 2A 123 6 15S.47 14 2A 123 1 15S.47 13 Attachment L-22-211 Page 51 of 89

SG Row Tube TSP INCH %TW 2A 123 27 16S -.65 11 2A 123 2 16S -.63 1 2A 123 3 S.66 17 2A 123 37 16S -.66 17 2A 123 3 16S -.5 15 2A 123 3 16S -.6 11 2A 123 42 16S -.73 17 2A 123 42 14S -.54 15 2A 123 44 16S -.63 16 2A 123 45 16S -.72 14 2A 123 51 16S -.67 13 2A 123 52 16S -.61 17 2A 123 15S -.47 12 2A 123 2 15S -.14 13 2A 123 1 1 16S -.64 16 2A 123 1 2 16S -.64 13 2A 123 1 3 16S -.11 2 2A 124 12 14S -.5 2A 124 37 16S -.66 11 2A 124 3 16S -.61 14 2A 124 42 16S -.55 14 2A 124 43 16S -.5 12 2A 124 44 16S -.57 11 2A 124 52 15S -. 7 2 2A 124 75 15S -.52 15 2A 124 7 15S.45 13 2A 124 7 15S -.52 2A 124 16S -.65 13 2A 125 1 15S.45 13 2A 125 16 15S.3 14 2A 125 22 16S -.63 15 2A 125 41 16S -.71 13 2A 125 42 16S -.75 12 2A 125 47 16S -.71 13 2A 125 61 15S -.55 7 2A 125 74 15S -. 5 22 2A 125 7 15S -. 5 21 2A 125 4 16S -. 7 15 2A 125 6 16S -. 1 2A 125 4 16S 11 2A 125 16S -.54 11 2A 125 16S -.11 2 Attachment L-22-211 Page 52 of 89

SG Row Tube TSP INCH %TW 2A 125 1 16S -.11 32 2A 126 1 16S -.12 33 2A 126 11 14S -.55 2A 126 37 16S -.6 15 2A 126 3 16S -.67 15 2A 126 3 16S -.66 17 2A 126 4 16S -.6 12 2A 126 44 16S -.54 17 2A 126 4 16S -.67 12 2A 126 1 16S -. 3 14 2A 126 2 16S -.14 1 2A 126 16S -.11 31 2A 127 1 16S -.12 33 2A 127 1 14S -.5 1 2A 127 14S -.52 11 2A 127 16S -.61 14 2A 127 1 14S -.54 2A 127 1 14S -.54 2A 127 2 14S -.54 16 2A 127 31 16S -.6 14 2A 127 37 16S -.5 15 2A 127 42 16S -.5 17 2A 127 45 16S -.56 1 2A 127 4 16S -.5 16 2A 127 64 15S -. 1 2A 127 66 15S -.57 1 2A 127 71 15S -. 7 1 2A 127 6 16S -.14 15 2A 12 1 16S -.12 14 2A 12 1 14S -.52 11 2A 12 5 14S -.53 15 2A 12 6 15S.4 12 2A 12 15S.44 12 2A 12 33 16S -.74 13 2A 12 4 16S -.56 17 2A 12 43 16S -.7 13 2A 12 45 16S -.76 14 2A 12 63 15S.35 16 2A 12 2 16S -.66 1 2A 12 5 16S -. 7 32 2A 12 1 16S -.12 22 2A 12 1 14S -.5 1 Attachment L-22-211 Page 53 of 89

SG Row Tube TSP INCH %TW 2A 12 6 14S -.52 1 2A 12 7 16S -.65 11 2A 12 1 15S.4 15 2A 12 21 16S -.54 12 2A 12 36 16S -.6 16 2A 12 3 16S.3 7 2A 12 3 14S -.5 13 2A 12 43 15S.37 1 2A 12 45 16S -.76 11 2A 12 7 15S -.52 12 2A 12 77 15S -.57 12 2A 12 4 16S.53 12 2A 12 2 16S -. 23 2A 12 4 16S -.11 3 2A 13 17 15S -.5 11 2A 13 35 16S -.6 13 2A 13 42 16S -.74 13 2A 13 45 16S -.74 15 2A 13 56 15S -.51 13 2A 13 16S.3 1 2A 131 1 16S.31 15 2A 131 1 14S -.52 14 2A 131 11 16S -.63 1 2A 131 11 14S -.52 11 2A 131 14 15S -.57 13 2A 131 16 16S -.5 1 2A 131 23 16S -.61 15 2A 131 23 14S -.52 23 2A 131 26 16S -.74 12 2A 131 31 16S -.67 15 2A 131 36 16S -.6 2A 131 3 16S -.7 11 2A 131 3 16S -.14 15 2A 131 45 16S -.6 11 2A 131 55 15S.5 11 2A 131 6 15S.37 15 2A 131 65 15S -.54 11 2A 131 67 15S -.55 15 2A 131 16S -. 7 14 2A 131 16S -.5 14 2A 132 1 14S 15 2A 132 15S.47 14 Attachment L-22-211 Page 54 of 89

SG Row Tube TSP INCH %TW 2A 132 11 16S -.61 2A 132 13 16S -.67 11 2A 132 14 16S -.53 11 2A 132 15 16S -.5 15 2A 132 15 15S.4 12 2A 132 15 15S -.56 11 2A 132 17 16S -.63 1 2A 132 22 16S -.52 17 2A 132 36 16S -.67 12 2A 132 3 16S -.6 14 2A 132 42 16S -.7 13 2A 132 4 15S.32 13 2A 132 65 15S -. 1 2A 132 5 16S.34 12 2A 132 7 16S.35 12 2A 132 7 16S -.64 11 2A 132 16S -.11 3 2A 133 1 16S -. 32 2A 133 1 14S -.5 1 2A 133 2 14S -.5 13 2A 133 4 16S -.16 14 2A 133 6 16S -. 17 2A 133 15S.42 15 2A 133 16S -.61 11 2A 133 11 16S -.67 14 2A 133 13 16S -.52 11 2A 133 22 16S -.6 13 2A 133 22 13S.54 14 2A 133 23 16S -.5 15 2A 133 3 16S -.61 1 2A 133 35 16S -.64 2 2A 133 36 16S -.47 2 2A 133 4 16S -.64 13 2A 133 6 16S -.63 15 2A 133 61 15S -.54 16 2A 133 67 15S.3 15 2A 133 2 16S -.64 13 2A 133 3 16S -.5 14 2A 133 4 16S -.11 22 2A 133 6 16S -. 2 2A 134 1 14S -.4 16 2A 134 1 16S -. 14 Attachment L-22-211 Page 55 of 89

SG Row Tube TSP INCH %TW 2A 134 2 16S.27 14 2A 134 3 16S.3 12 2A 134 7 16S -.4 1 2A 134 16S -.53 13 2A 134 15 15S.44 11 2A 134 22 15S.42 12 2A 134 23 16S -.5 12 2A 134 25 16S -.7 13 2A 134 33 16S -.7 17 2A 134 3 16S -.6 14 2A 134 5 15S.44 1 2A 134 77 16S.43 16 2A 134 4 16S -. 17 2A 135 7 15S.46 1 2A 135 16S -.53 13 2A 135 1 16S -.52 11 2A 135 15 16S -.67 13 2A 135 1 14S -.5 2 2A 135 2 16S -.7 11 2A 135 35 14S -.54 11 2A 135 41 16S -.7 1 2A 135 6 16S -.5 1 2A 135 75 16S.42 13 2A 135 75 16S -.6 12 2A 135 77 16S -.14 1 2A 135 7 16S.45 11 2A 135 7 16S -.7 1 2A 135 16S -.62 12 2A 135 1 16S -.5 15 2A 135 2 16S -. 2 2A 136 1 16S -.12 27 2A 136 1 14S -.5 26 2A 136 3 14S -.52 12 2A 136 15S.37 21 2A 136 1 15S.42 14 2A 136 15 15S -.54 16 2A 136 17 16S -.72 24 2A 136 1 16S -.61 12 2A 136 1 16S -.61 16 2A 136 21 16S -.66 11 2A 136 22 16S -.12 1 2A 136 22 15S -. 23 Attachment L-22-211 Page 56 of 89

SG Row Tube TSP INCH %TW 2A 136 2 16S -.71 11 2A 136 3 16S -.52 13 2A 136 31 16S -.5 15 2A 136 35 16S -.7 14 2A 136 4 15S.4 14 2A 136 52 15S -.61 11 2A 136 57 16S -.56 11 2A 136 5 15S.4 22 2A 136 77 16S -. 1 12 2A 136 16S -.11 2 2A 137 5 16S -.65 12 2A 137 5 14S -.54 1 2A 137 11 15S.42 12 2A 137 14 16S -.65 13 2A 137 15 15S -. 24 2A 137 16 16S -.5 16 2A 137 17 16S -.54 13 2A 137 2 16S -.64 14 2A 137 22 16S -.56 11 2A 137 31 16S -.6 12 2A 137 32 16S -.6 14 2A 137 37 16S -.73 13 2A 137 3 16S -.71 14 2A 137 53 15S -.64 11 2A 137 61 15S -.61 2A 137 6 16S.35 21 2A 137 76 16S -.22 21 2A 137 77 16S -.13 26 2A 13 1 14S -.5 11 2A 13 1 16S.36 11 2A 13 2 14S -.52 14 2A 13 16S -.56 14 2A 13 1 16S -.6 16 2A 13 13 16S -.67 14 2A 13 22 16S -.62 12 2A 13 26 16S -.55 21 2A 13 2 16S -.51 13 2A 13 2 15S -.5 7 2A 13 4 15S -.6 14 2A 13 61 15S -.5 2A 13 2 14S -.5 13 2A 13 3 14S -.5 1 Attachment L-22-211 Page 57 of 89

SG Row Tube TSP INCH %TW 2A 13 4 16S -.63 14 2A 13 6 16S -.12 22 2A 13 7 14S -.55 11 2A 13 16S -.67 1 2A 13 15S.42 22 2A 13 1 16S -.6 16 2A 13 11 16S -.63 13 2A 13 12 16S -.6 12 2A 13 13 16S -.5 17 2A 13 14 16S -.56 16 2A 13 15 16S -.6 11 2A 13 17 16S -.6 11 2A 13 21 16S -.64 13 2A 13 22 16S -.64 14 2A 13 25 16S -.55 17 2A 13 31 16S -.7 13 2A 13 33 16S -.7 1 2A 13 37 16S -.6 17 2A 13 4 15S -.63 11 2A 13 54 15S.4 1 2A 13 63 15S -.54 2A 13 66 16S -.12 25 2A 13 67 16S.35 13 2A 13 67 16S -.56 12 2A 13 6 16S -.14 23 2A 13 7 16S.22 1 2A 13 7 16S -.57 24 2A 13 73 16S -.62 13 2A 14 2 16S.2 15 2A 14 2 14S -.5 11 2A 14 16S -.61 15 2A 14 1 14S -.52 1 2A 14 14 16S -.61 14 2A 14 1 16S -.6 12 2A 14 1 16S -.55 15 2A 14 2 16S -.7 13 2A 14 21 16S -.64 14 2A 14 27 16S -.57 1 2A 14 2 16S -.6 15 2A 14 3 16S -.7 13 2A 14 31 16S -.56 1 2A 14 32 16S -.5 1 Attachment L-22-211 Page 58 of 89

SG Row Tube TSP INCH %TW 2A 14 35 16S -.77 12 2A 14 3 16S -.14 21 2A 14 3 15S -. 1 2A 14 64 16S -.5 17 2A 14 66 16S -.61 14 2A 14 6 16S.3 16 2A 14 6 16S -.67 13 2A 14 7 16S -.12 3 2A 141 1 16S -.12 42 2A 141 1 14S -.41 26 2A 141 2 16S -.14 16 2A 141 5 14S -.52 11 2A 141 6 16S -.5 11 2A 141 7 16S -.61 12 2A 141 16S -.6 12 2A 141 16S -.12 1 2A 141 1 16S -.6 13 2A 141 11 16S -.67 13 2A 141 12 16S -. 22 2A 141 12 15S.3 21 2A 141 13 15S -. 26 2A 141 14 16S -.65 14 2A 141 15 16S -.76 12 2A 141 16 16S -.45 2 2A 141 16 14S -.5 13 2A 141 17 16S -.71 14 2A 141 1 16S -.52 16 2A 141 22 16S -.76 5 2A 141 25 16S -.71 1 2A 141 2 16S -.57 1 2A 141 3 16S -.5 1 2A 141 36 15S -.56 15 2A 141 3 16S -.6 13 2A 141 63 16S.2 13 2A 141 66 16S.27 1 2A 141 66 16S -.56 12 2A 141 67 16S.3 2 2A 141 67 16S -.55 1 2A 142 5 16S -.61 2A 142 1 15S.21 23 2A 142 11 15S.32 14 2A 142 12 14S -.52 15 Attachment L-22-211 Page 59 of 89

SG Row Tube TSP INCH %TW 2A 142 13 16S -.5 21 2A 142 14 16S -.47 2 2A 142 14 15S.47 24 2A 142 1 16S -.73 11 2A 142 1 15S.25 21 2A 142 22 16S -.6 14 2A 142 24 16S -.64 14 2A 142 25 16S -.64 16 2A 142 26 16S -.77 13 2A 142 2 16S -.57 15 2A 142 3 15S -.5 11 2A 142 6 16S -.54 17 2A 142 62 16S.2 1 2A 142 62 16S -.61 12 2A 142 64 16S.3 1 2A 142 65 16S -.55 13 2A 143 2 16S -.12 23 2A 143 2 14S -.5 12 2A 143 6 16S -.12 17 2A 143 6 14S -.52 14 2A 143 16S -.5 14 2A 143 14S -.52 13 2A 143 16S -.55 21 2A 143 14S -.47 15 2A 143 11 16S -.5 21 2A 143 11 15S.54 17 2A 143 12 16S -.47 1 2A 143 13 16S -.52 1 2A 143 14 16S -.62 12 2A 143 14 15S.37 15 2A 143 17 16S -.73 11 2A 143 21 16S -.64 12 2A 143 22 16S -.6 11 2A 143 26 16S -.6 17 2A 143 31 16S -.47 14 2A 143 4 16S -.67 12 2A 143 52 16S -.65 11 2A 143 5 16S.33 15 2A 143 5 16S -.61 17 2A 143 6 16S.2 1 2A 143 61 16S.35 14 2A 143 61 16S -.61 1 Attachment L-22-211 Page 60 of 89

SG Row Tube TSP INCH %TW 2A 144 1 16S -.12 3 2A 144 1 14S 35 2A 144 2 14S -.52 12 2A 144 4 14S -.52 17 2A 144 5 16S -.63 1 2A 144 5 14S -.54 14 2A 144 6 16S -.72 13 2A 144 16S -.6 14 2A 144 14S -.52 13 2A 144 11 15S.2 1 2A 144 12 15S -. 7 26 2A 144 1 16S -.6 16 2A 144 1 16S -.62 1 2A 144 2 16S -.64 12 2A 144 2 15S.52 17 2A 144 2 14S -.56 1 2A 144 21 16S -.62 15 2A 144 22 16S -.64 16 2A 144 25 16S -.71 2A 144 2 16S -.65 11 2A 144 44 16S -.53 17 2A 144 46 16S -.12 21 2A 144 53 16S -.12 1 2A 144 54 16S.35 13 2A 144 56 16S -. 24 2A 144 57 16S -.5 14 2A 145 1 16S -.14 27 2A 145 1 14S -.5 35 2A 145 2 14S -.54 2 2A 145 3 16S -.42 16 2A 145 3 14S -.5 1 2A 145 4 14S -.53 11 2A 145 4 16S -.56 16 2A 145 5 16S -. 24 2A 145 5 14S -.56 11 2A 145 7 16S -. 16 2A 145 7 14S -.55 14 2A 145 16S -.11 17 2A 145 1 16S -.11 17 2A 145 12 16S.27 13 2A 145 13 16S.32 11 2A 145 13 16S -.6 16 Attachment L-22-211 Page 61 of 89

SG Row Tube TSP INCH %TW 2A 145 14 15S.3 23 2A 145 15 15S.45 21 2A 145 16 16S -.61 17 2A 145 16 14S -.52 12 2A 145 17 16S -.63 15 2A 145 1 15S.43 1 2A 145 1 16S -.12 1 2A 145 2 16S -.52 15 2A 145 21 16S -.5 16 2A 145 22 16S.3 13 2A 145 25 16S -.77 14 2A 145 31 16S -.67 11 2A 145 31 15S -.43 12 2A 145 37 16S -.5 13 2A 145 3 16S -.1 21 2A 145 41 16S -.55 14 2A 145 42 16S -.5 12 2A 145 44 16S -. 16 2A 145 47 16S -.55 14 2A 145 4 16S -.56 1 2A 145 5 16S -.6 16 2A 145 51 16S -.12 1 2A 145 52 16S -.16 1 2A 146 1 16S -.5 11 2A 146 1 14S -.41 16 2A 146 2 14S -.51 34 2A 146 2 16S -.11 2 2A 146 3 14S -.57 14 2A 146 4 16S -.12 24 2A 146 5 14S -.52 14 2A 146 5 16S -. 1 2A 146 7 16S -.12 21 2A 146 7 14S -.56 14 2A 146 14S -.4 11 2A 146 1 16S -. 1 2A 146 12 16S -.71 12 2A 146 13 16S -.63 12 2A 146 14 16S -.61 12 2A 146 14 14S -.54 11 2A 146 15 16S -.4 23 2A 146 15 14S -.5 15 2A 146 16 16S -.6 11 Attachment L-22-211 Page 62 of 89

SG Row Tube TSP INCH %TW 2A 146 17 16S -.54 13 2A 146 17 14S -.5 12 2A 146 2 16S -. 2 1 2A 146 21 16S.4 2A 146 22 12S -.

2A 146 22 16S -.25 15 2A 146 23 16S -.6 14 2A 146 24 15S.41 2 2A 146 2 15S -.46 2A 146 34 16S -.55 15 2A 146 35 16S -.6 15 2A 146 36 16S -.56 1 2A 146 3 16S -.55 16 2A 146 4 16S -.55 1 2A 146 41 16S -.11 14 2A 146 42 16S -.12 14 2A 146 47 16S -.53 17 2A 146 4 16S.36 11 2A 146 4 16S -.61 13 2A 147 1 16S -.63 15 2A 147 1 14S -.52 21 2A 147 2 16S -. 27 2A 147 2 14S -.46 36 2A 147 3 14S -.54 15 2A 147 4 16S -.64 14 2A 147 4 14S -.54 13 2A 147 5 16S -.5 17 2A 147 5 14S -.5 13 2A 147 6 16S -.52 15 2A 147 7 16S -.64 15 2A 147 16S -.61 22 2A 147 16S -.53 1 2A 147 1 16S.43 12 2A 147 1 16S -.6 1 2A 147 11 16S.36 13 2A 147 12 16S -.74 16 2A 147 14 16S -.47 17 2A 147 15 16S -.55 14 2A 147 16 16S -.52 1 2A 147 17 16S -.66 16 2A 147 1 16S -.73 14 2A 147 2 16S -.64 17 Attachment L-22-211 Page 63 of 89

SG Row Tube TSP INCH %TW 2A 147 2 15S.47 1 2A 147 22 16S -.64 11 2A 147 25 15S -.57 1 2A 147 32 16S -.44 2 2A 147 36 16S -.55 14 2A 147 4 16S -.53 1 2A 147 41 16S -.5 21 2A 147 42 16S.26 11 2A 147 42 16S -.54 15 2A 147 43 16S -.55 1 2A 147 45 16S.24 16 2A 147 45 16S -.54 22 2A 14 1 14S -.5 24 2A 14 3 14S -.54 2 2A 14 5 16S -.52 23 2A 14 5 14S -.4 2A 14 6 16S -.5 14 2A 14 7 16S -.67 14 2A 14 16S -.6 15 2A 14 1 16S.2 1 2A 14 11 16S -.47 1 2A 14 12 16S -.45 22 2A 14 13 16S -.64 1 2A 14 15 16S -.65 2 2A 14 2 16S -.73 11 2A 14 36 16S -.12 17 2A 14 37 16S -.53 17 2A 14 3 16S -.14 25 2A 14 3 16S -.54 16 2A 14 4 16S -.56 25 2A 14 1 14S -. 5 3 2A 14 2 16S -.12 2 2A 14 2 14S -.61 14 2A 14 3 16S -. 2 2A 14 3 14S -.55 23 2A 14 4 14S -.4 17 2A 14 5 16S -.5 23 2A 14 5 14S -.52 1 2A 14 7 16S -.61 2 2A 14 16S -.5 15 2A 14 16S -.4 22 2A 14 11 16S -.76 14 Attachment L-22-211 Page 64 of 89

SG Row Tube TSP INCH %TW 2A 14 12 16S -.14 21 2A 14 13 16S -.12 16 2A 14 14 16S -.12 17 2A 14 15 16S -.11 22 2A 14 16 16S -.14 1 2A 14 17 16S -.14 21 2A 14 1 16S -.75 27 2A 14 1 16S -.6 2 2A 14 2 16S -.6 16 2A 14 24 16S.2 13 2A 14 26 16S.2 14 2A 14 33 16S -.51 1 2A 15 1 14S -.4 16 2A 15 2 16S -.67 1 2A 15 2 14S -.41 16 2A 15 3 16S -.14 32 2A 15 3 14S -.53 15 2A 15 4 16S -.12 31 2A 15 4 14S -. 2 36 2A 15 6 14S -. 2 3 2A 15 16S -.71 16 2A 15 16S -.55 17 2A 15 1 16S -.12 24 2A 15 11 16S -.16 26 2A 15 12 14S 32 2A 15 12 16S -.11 2 2A 15 13 16S -.12 2 2A 15 14 16S -.65 23 2A 15 16 16S.43 14 2A 15 17 16S -.12 27 2A 15 25 16S.26 11 2A 151 2 16S -.14 2 2A 151 2 14S -. 2 42 2A 151 3 16S -.64 23 2A 151 4 16S -.16 3 2A 151 4 14S -. 2 35 2A 151 5 16S -.14 16 2A 151 6 16S -.16 27 2A 151 6 14S -.5 11 2A 151 7 16S -.16 35 2A 151 16S -.14 26 2A 151 1 16S -.66 22 Attachment L-22-211 Page 65 of 89

SG Row Tube TSP INCH %TW 2A 151 11 16S -.16 2 2A 151 12 16S -.12 15 2A 151 13 16S -.16 2 2A 151 14 16S -.16 1 1B 1 4 12S.57 13 1B 1 7 16S -.5 12 1B 1 16S -.61 12 1B 1 16S -.63 12 1B 1 12 14S.46 14 1B 1 13 14S.4 1 1B 1 16 16S -.11 2 1B 1 16 14S.5 11 1B 2 1 16S -.5 13 1B 2 1 12S.52 12 1B 2 24 1S -.27 14 1B 3 3 14S -.55 1 1B 3 34 16S -. 2 1B 3 34 1S -.27 12 1B 4 1 16S -.61 16 1B 4 2 16S -.5 12 1B 4 2 16S.24 15 1B 4 1 16S -.61 12 1B 4 2 16S -.54 14 1B 4 41 16S -. 31 1B 5 1 16S -.11 35 1B 5 27 15S -. 5 15 1B 5 46 16S -.5 23 1B 6 1 16S -.55 27 1B 6 2 16S.35 16 1B 6 16 15S -.61 13 1B 6 35 15S.37 11 1B 7 1 16S -.12 17 1B 7 13 15S -.62 12 1B 1 16S -.53 1 1B 14 16S -.53 13 1B 2 16S -.56 13 1B 57 16S -.11 2 1B 1 16S -.11 2 1B 2 15S -.57 12 1B 2 15S -.5 13 1B 1 1 16S -.55 25 1B 1 4 16S -.57 16 Attachment L-22-211 Page 66 of 89

SG Row Tube TSP INCH %TW 1B 1 16S -.73 13 1B 1 42 1 S.61 1 1B 1 65 16S -.14 3 1B 11 1 16S -.13 35 1B 11 4 16S -.6 11 1B 11 12 16S -.53 13 1B 11 44 1 S.64 11 1B 12 1 16S -.16 27 1B 12 16S.26 14 1B 12 13 16S -.5 12 1B 12 1 15S -.57 13 1B 12 71 16S.37 12 1B 13 6 16S -.12 17 1B 13 16S -.5 1 1B 13 15 16S -.74 1 1B 14 5 16S -.53 11 1B 14 2 15S -.55 12 1B 14 5 15S -.5 14 1B 14 74 16S.2 14 1B 14 75 16S -. 23 1B 15 1 16S -.16 4 1B 15 11 16S -.76 13 1B 15 3 16S -.63 14 1B 15 5 15S -.61 14 1B 16 1 16S -.7 1 1B 16 52 15S -.5 14 1B 16 54 15S -.62 13 1B 16 13S.5 12 1B 16 1 1S.66 12 1B 17 1 15S -.57 11 1B 1 1 16S -.14 2 1B 1 3 16S.42 13 1B 1 16S -.71 11 1B 1 15S -.5 1 1B 1 2 15S -.54 12 1B 1 5 15S -.55 14 1B 1 73 16S -.6 1 1B 1 5 16S -.11 17 1B 1 1 16S -.7 21 1B 1 3 16S -.74 1 1B 1 6 16S.47 1 1B 1 16S.24 1 Attachment L-22-211 Page 67 of 89

SG Row Tube TSP INCH %TW 1B 1 14 15S -.55 11 1B 1 56 15S -.66 13 1B 1 73 16S.3 13 1B 2 1 16S -.11 26 1B 2 4 16S.5 11 1B 2 13 16S -.7 12 1B 2 23 16S -.5 11 1B 2 26 16S -.61 1 1B 2 62 15S -.5 13 1B 2 77 15S.44 11 1B 21 1 16S -. 17 1B 21 2 16S -.6 12 1B 21 3 16S -.6 11 1B 21 4 16S -.7 1 1B 21 16S.41 11 1B 21 16S -.72 11 1B 21 16S -.76 1 1B 21 1 16S -.74 11 1B 21 13 16S -.72 15 1B 21 16 16S -.62 14 1B 21 51 15S -.6 11 1B 21 52 15S -.61 1 1B 21 63 15S -.55 1 1B 21 16S -. 21 1B 22 1 16S -.14 3 1B 22 16S.44 14 1B 22 15 16S -.62 12 1B 23 1 16S -.13 14 1B 23 5 16S.44 11 1B 23 6 16S -.14 14 1B 23 7 16S -.74 15 1B 23 6 16S -.55 16 1B 23 73 15S -.5 13 1B 24 5 16S.35 15 1B 24 6 16S -.72 15 1B 24 16S -.75 13 1B 24 14 16S -. 13 1B 24 5 15S -.61 12 1B 24 53 15S -.65 11 1B 24 15S.46 12 1B 25 7 16S -.71 11 1B 25 25 16S -. 1 12 Attachment L-22-211 Page 68 of 89

SG Row Tube TSP INCH %TW 1B 25 73 15S -.57 11 1B 25 1 15S -.6 1 1B 26 4 16S -.67 13 1B 26 73 15S -.61 11 1B 27 1 16S -.1 26 1B 27 2 16S -. 2 14 1B 27 35 16S -.66 11 1B 27 71 16S -.54 13 1B 27 15S -.62 12 1B 27 1 15S -.55 12 1B 27 1 15S -.64 14 1B 2 3 16S -.71 24 1B 2 7 16S -. 2 15 1B 2 56 15S -.57 13 1B 2 57 16S -.53 14 1B 2 1 16S -.13 26 1B 2 16S -.6 14 1B 2 54 15S -.55 11 1B 2 5 16S -.66 1 1B 2 62 16S -.6 13 1B 2 63 16S -.5 1 1B 2 1 4 1S -.37 11 1B 3 3 16S -.77 1 1B 3 16S -.77 1 1B 3 16S -.7 16 1B 3 2 14S -.57 14 1B 3 63 16S -.57 13 1B 3 74 16S -.63 12 1B 3 16S.41 12 1B 3 1 1 16S.34 12 1B 31 3 16S -.73 12 1B 32 5 16S -. 12 1B 32 14 16S -. 1 1 1B 32 61 16S -.5 1 1B 32 6 16S -.5 14 1B 32 71 15S -.5 13 1B 33 73 15S -.66 12 1B 34 1 16S -.14 33 1B 34 47 16S -.66 1B 34 15S -.64 15 1B 35 3 16S -.6 11 1B 35 35 16S -.6 13 Attachment L-22-211 Page 69 of 89

SG Row Tube TSP INCH %TW 1B 35 76 15S -.64 12 1B 35 77 15S -.55 11 1B 35 3 15S -.62 16 1B 36 5 16S -.7 15 1B 36 15S -.55 11 1B 36 16 15S. 2 13 1B 36 37 16S -.72 12 1B 36 2 15S -.64 12 1B 36 5 16S.33 13 1B 36 6 16S -.76 13 1B 37 1 16S -.6 1 1B 37 2 16S -.74 11 1B 37 16S -.5 12 1B 37 5 16S.31 11 1B 37 114 11S.52 12 1B 3 1 16S -.7 11 1B 3 4 16S -.74 11 1B 3 7 16S -.75 12 1B 3 76 15S -.6 13 1B 3 6 15S -.62 14 1B 3 1 4 16S -.55 17 1B 3 1 6 16S -.56 13 1B 3 113 16S -.51 14 1B 3 5 16S -.64 11 1B 3 1 16S -.7 11 1B 3 11 16S -.75 15 1B 3 16S.33 1 1B 3 15S -.66 11 1B 3 116 16S 17 1B 4 4 16S -.61 14 1B 4 5 16S -.76 12 1B 4 1 1 16S -.55 13 1B 4 112 15S -.64 14 1B 4 113 16S.33 12 1B 4 114 16S -.53 15 1B 4 117 16S -. 27 1B 41 3 16S -.63 1 1B 41 33 16S -.6 13 1B 41 5 16S -.56 13 1B 41 15S -.64 1 1B 41 2 15S -.5 1 1B 41 1 2 16S -.5 13 Attachment L-22-211 Page 70 of 89

SG Row Tube TSP INCH %TW 1B 41 115 16S.26 12 1B 42 1 16S -.6 12 1B 42 2 16S -.63 12 1B 42 3 16S -.74 1B 42 5 16S -.61 11 1B 42 16S -.75 12 1B 42 1 16S.33 11 1B 42 16S -.53 13 1B 42 1 4 16S -.5 1 1B 42 1 4 15S -.64 12 1B 42 1 7 16S -. 2 16 1B 43 1 16S -.66 14 1B 43 1 16S -.5 16 1B 43 1 4 16S.3 11 1B 44 1 16S -.12 23 1B 44 2 16S -.66 1 1B 44 13 16S -.7 13 1B 44 5 16S -.57 13 1B 44 1 16S -.53 17 1B 44 1 1 16S.35 1 1B 44 11 11S.43 13 1B 45 1 16S -.14 1 1B 45 4 16S -.63 1 1B 45 56 15S -.66 1B 45 16S -.5 14 1B 46 1 16S -. 16 1B 46 3 16S -.72 11 1B 46 4 16S -.5 12 1B 46 12 16S -.74 12 1B 46 16S -.61 14 1B 46 16S.2 11 1B 46 113 16S.35 14 1B 46 114 15S -.71 15 1B 46 115 15S -.64 14 1B 47 1 16S -.5 21 1B 47 2 16S -.73 12 1B 4 3 16S -.53 14 1B 4 6 16S -.71 17 1B 4 16S -.12 2 1B 4 1 16S.33 15 1B 4 14 16S -. 1 1B 4 1 7 16S -.56 13 Attachment L-22-211 Page 71 of 89

SG Row Tube TSP INCH %TW 1B 4 123 16S -. 22 1B 4 7 15S -.6 1 1B 4 16S -.63 13 1B 4 1 16S -.67 1 1B 4 1 16S -. 3 11 1B 4 124 16S -. 26 1B 5 1 11S.46 1 1B 5 2 16S -.55 12 1B 5 4 16S -.51 11 1B 5 11 16S -.77 1 1B 5 24 16S -. 2 13 1B 5 117 15S -.64 1 1B 51 1 11S.5 13 1B 51 3 16S -.54 12 1B 51 23 16S -.77 12 1B 52 2 16S.3 1 1B 52 16S -.66 12 1B 52 11 16S -.65 1 1B 52 12 16S -.73 1B 52 6 16S -.63 12 1B 52 115 15S -.64 11 1B 53 1 16S -.57 13 1B 53 16S -.7 11 1B 53 16S -.62 12 1B 53 115 16S -.74 13 1B 53 11 16S -.65 13 1B 53 11 15S.42 14 1B 53 126 16S -.12 21 1B 54 2 16S -.55 1 1B 54 15S -.5 11 1B 54 25 13S -.57 1B 54 12 15S.53 13 1B 54 127 16S -.57 1 1B 55 3 16S -.57 11 1B 55 1 16S -.6 1 1B 55 12 15S.5 13 1B 55 12 15S -.66 1 1B 55 121 15S.4 12 1B 55 121 15S -.64 12 1B 56 2 16S -.67 12 1B 56 6 16S -.6 14 1B 56 122 15S.53 16 Attachment L-22-211 Page 72 of 89

SG Row Tube TSP INCH %TW 1B 56 123 15S.51 1 1B 56 124 15S.51 13 1B 57 1 16S -.5 17 1B 57 7 16S -.7 12 1B 57 11 16S -.67 1 1B 57 16S -.6 13 1B 57 11 15S -.5 1B 57 125 15S -.5 13 1B 57 12 16S -. 2 1B 5 1 11S. 7 12 1B 5 2 16S -.61 12 1B 5 15 16S -.74 16 1B 5 121 15S -.62 1B 5 12 16S -. 27 1B 5 1 16S -.56 17 1B 5 2 16S -.56 12 1B 5 121 15S -.61 12 1B 6 16S -.62 14 1B 6 1 15S -.64 11 1B 6 121 15S -.64 1 1B 6 12 16S -. 7 2 1B 61 2 16S -.54 1 1B 61 3 16S -.67 12 1B 61 126 16S.44 13 1B 61 13 16S -.65 1 1B 62 1 16S -.56 21 1B 62 5 16S -.54 15 1B 62 16S -.61 13 1B 62 1 5 16S -.62 14 1B 62 123 16S -.65 12 1B 62 125 16S -.67 11 1B 62 126 16S -.63 11 1B 62 12 16S.44 15 1B 63 1 16S -.54 1 1B 63 12 16S -.74 15 1B 63 12 16S.26 13 1B 63 13 16S -. 2 1B 63 13 13S. 2 21 1B 64 127 16S -.73 11 1B 64 12 16S.37 11 1B 64 13 16S.4 17 1B 64 131 16S -. 27 Attachment L-22-211 Page 73 of 89

SG Row Tube TSP INCH %TW 1B 64 131 14S -.46 1 1B 65 3 16S -.62 1 1B 65 15S -.5 11 1B 65 123 16S -.6 13 1B 65 12 16S.44 11 1B 65 13 16S.44 15 1B 65 13 14S.4 11 1B 65 13 13S.44 15 1B 66 2 16S -.55 11 1B 66 3 16S -.57 16 1B 66 4 16S -.66 16 1B 66 5 16S -.54 15 1B 66 6 16S -.54 17 1B 66 7 16S -.72 15 1B 66 1 16S -.76 11 1B 66 12 16S.37 13 1B 66 12 16S -.5 14 1B 66 13 16S -. 22 1B 66 131 16S -.14 23 1B 66 131 13S -.37 1B 66 131 14S -. 16 1B 67 2 16S -.51 12 1B 67 13 16S -.77 16 1B 67 15 16S -.7 12 1B 67 12 16S -.63 12 1B 67 126 16S.27 15 1B 67 12 16S.46 13 1B 6 1 16S -.54 27 1B 6 2 16S -.56 15 1B 6 4 16S -.65 14 1B 6 6 16S -.5 12 1B 6 12 16S -.65 16 1B 6 117 16S -.62 1 1B 6 122 16S -.64 12 1B 6 127 15S -.71 12 1B 6 12 15S.5 16 1B 6 131 16S -.11 3 1B 6 131 13S. 5 23 1B 6 131 11S.5 12 1B 6 131 14S. 5 2 1B 6 4 15S.55 13 1B 6 14 16S -.75 12 Attachment L-22-211 Page 74 of 89

SG Row Tube TSP INCH %TW 1B 6 1 16S -.76 1 1B 6 1 5 16S -.6 12 1B 6 126 15S.43 13 1B 6 126 15S -.52 11 1B 6 131 13S.46 13 1B 7 1 16S -.56 15 1B 7 2 16S -.56 15 1B 7 5 16S -.54 13 1B 7 6 16S -.5 12 1B 7 7 15S -.53 11 1B 7 17 16S -. 2 1 1B 7 1 16S -.7 1 1B 7 111 16S -.66 11 1B 7 122 16S -.63 1 1B 7 12 16S -.73 11 1B 71 16S -.6 15 1B 71 17 15S -.62 13 1B 71 2 16S -.76 13 1B 71 117 16S -.76 12 1B 71 11 16S -.6 11 1B 71 126 16S -.73 13 1B 71 127 16S -.6 11 1B 72 1 16S -.61 12 1B 72 2 16S.33 12 1B 72 3 15S.57 13 1B 72 4 16S -.64 13 1B 72 6 16S -.57 14 1B 72 11 16S -.77 15 1B 72 14 16S -.72 12 1B 72 115 16S -.64 1 1B 72 116 16S -.5 11 1B 72 12 16S.4 1 1B 72 126 16S -.73 13 1B 72 12 16S.36 13 1B 72 131 16S -. 2 1B 73 3 16S -.64 1 1B 73 3 15S -. 1 1B 73 4 16S -.67 15 1B 73 5 16S -.57 16 1B 73 1 16S.33 12 1B 73 12 16S -.72 1 1B 73 13 16S -.74 11 Attachment L-22-211 Page 75 of 89

SG Row Tube TSP INCH %TW 1B 73 12 16S -.62 11 1B 73 122 16S -.75 1B 73 125 16S -.64 13 1B 73 127 16S -.66 15 1B 73 12 16S.37 11 1B 73 131 16S -.71 12 1B 73 131 11S.6 26 1B 73 132 16S -.11 33 1B 74 1 16S -.56 23 1B 74 2 16S -.51 17 1B 74 3 16S -.57 2 1B 74 3 15S.54 14 1B 74 3 15S -.63 14 1B 74 6 16S -.52 15 1B 74 11 16S -.65 1 1B 74 14 16S -.77 15 1B 74 15 16S -.76 1 1B 74 1 16S -. 2 1 1B 74 1 7 16S -.6 11 1B 74 13 16S -.14 1 1B 74 13 14S.5 11 1B 74 131 16S -. 7 15 1B 74 131 11S.57 12 1B 74 131 14S 15 1B 74 131 13S 13 1B 75 1 16S -.56 11 1B 75 1 12S -.41 1B 75 2 16S -.56 24 1B 75 5 16S -.5 1 1B 75 6 15S -.63 12 1B 75 16S -.7 14 1B 75 11 16S -.7 12 1B 75 14 16S -.75 1 1B 75 15 16S -.72 11 1B 75 1 5 16S -.62 12 1B 75 12 16S -.61 1 1B 75 123 16S -.76 11 1B 75 124 16S -.56 12 1B 75 13 16S -.53 15 1B 75 13 14S.4 13 1B 75 13 13S.43 14 1B 75 131 16S -.71 15 Attachment L-22-211 Page 76 of 89

SG Row Tube TSP INCH %TW 1B 75 131 14S.4 14 1B 75 131 11S.55 16 1B 75 132 16S -.57 14 1B 75 132 14S -.46 15 1B 76 1 16S.22 27 1B 76 1 16S -.54 11 1B 76 1 11S -.46 15 1B 76 2 16S.26 24 1B 76 1 16S -.75 1B 76 2 16S -.71 15 1B 76 115 16S -.6 1B 76 116 14S -. 2 14 1B 76 122 16S -.63 14 1B 76 123 16S -.67 14 1B 76 127 16S -.76 16 1B 76 12 16S -. 7 16 1B 76 13 16S -.71 17 1B 76 131 16S -.52 1 1B 76 131 11S.55 14 1B 77 1 11S.11 23 1B 77 2 11S.71 11 1B 77 4 16S -.62 11 1B 77 5 16S -.54 12 1B 77 21 16S -. 2 12 1B 77 1 4 15S -.5 13 1B 77 1 15S -.14 17 1B 77 12 16S -.71 11 1B 77 132 16S -.57 11 1B 77 132 14S -.34 1B 77 132 13S -. 2 1 1B 7 1 16S -.11 14 1B 7 1 11S.67 1 1B 7 1 16S.3 12 1B 7 123 16S -.71 1B 7 127 16S -.55 14 1B 7 12 16S -.6 14 1B 7 13 16S -.52 13 1B 7 1 11S.57 22 1B 7 3 16S -.6 17 1B 7 5 16S -.54 14 1B 7 7 16S -.72 12 1B 7 116 14S.46 13 Attachment L-22-211 Page 77 of 89

SG Row Tube TSP INCH %TW 1B 7 132 13S -.34 1 1B 1 16S -. 1 1B 1 11S.62 13 1B 3 16S.37 11 1B 5 16S -.57 1B 124 16S -.55 11 1B 127 16S -.64 14 1B 12 16S -.64 1 1B 1 1 16S -. 3 1B 1 2 16S -.12 16 1B 1 3 16S.3 12 1B 1 122 16S -.6 16 1B 1 126 16S -.62 13 1B 1 132 16S -.14 1 1B 2 1 16S.2 14 1B 2 1 11S.62 16 1B 2 2 16S -.57 1B 2 3 16S.42 14 1B 2 115 16S -.57 14 1B 2 123 16S -.73 1 1B 2 131 11S.5 1 1B 3 1 11S.5 13 1B 3 1 16S.33 12 1B 3 2 16S -.5 12 1B 3 2 11S.64 13 1B 3 5 16S.2 13 1B 3 113 16S -.6 1 1B 3 11 16S -.6 1 1B 3 12 16S -.53 12 1B 3 121 15S -.57 13 1B 3 122 16S -.66 12 1B 3 12 16S -.62 13 1B 4 1 11S.74 1 1B 4 1 16S -.12 23 1B 4 3 16S -.6 11 1B 4 5 16S -.54 1 1B 4 7 16S -.7 1 1B 4 125 16S -.62 13 1B 4 12 16S -.62 1B 5 1 16S.35 12 1B 5 123 16S -.57 1 1B 6 5 16S -.12 22 Attachment L-22-211 Page 78 of 89

SG Row Tube TSP INCH %TW 1B 6 7 16S -.77 12 1B 6 16S -.7 1 1B 6 16 16S -.63 1B 6 131 16S -.57 11 1B 7 1 16S.24 14 1B 7 1 11S.54 11 1B 7 116 16S -.5 12 1B 1 16S -. 5 21 1B 5 16S -.57 1B 7 16S -.7 1 1B 11 16S -.55 11 1B 126 16S -.6 1 1B 131 16S -.62 17 1B 131 14S -.3 1B 131 13S -.32 14 1B 1 16S -.5 1 1B 7 12S -.64 1B 13 16S -.11 21 1B 123 16S -.66 13 1B 1 1 16S -.14 17 1B 1 2 16S -.57 1 1B 1 13 14S.52 1 1B 2 1 16S -.12 1 1B 2 4 16S -.71 1 1B 2 16S -.72 13 1B 2 12 16S -.6 7 1B 2 124 16S -.57 14 1B 2 12 14S.5 14 1B 3 4 16S -.73 11 1B 3 3 15S -.6 1B 3 114 16S -.66 12 1B 4 1 16S -.12 2 1B 4 12 14S.4 14 1B 5 1 16S -. 31 1B 5 4 13S -.46 1 1B 5 1 1 15S -.64 13 1B 5 113 14S.34 1 1B 5 117 16S -.64 13 1B 7 5 15S.5 1 1B 7 2 15S.35 12 1B 7 12 16S -.55 12 1B 7 123 16S -.5 14 Attachment L-22-211 Page 79 of 89

SG Row Tube TSP INCH %TW 1B 1 7 15S -.57 11 1B 1 16S -.14 1 1B 4 16S -.57 1B 16S.45 1 1B 1 1 16S -.12 1 1B 1 4 16S -.5 1 1B 1 6 16S -.64 11 1B 1 1 4 15S -.46 14 1B 1 1 1 16S -.14 24 1B 1 1 1 1S.64 11 1B 1 1 116 16S -.6 1B 1 2 1 16S -.75 11 1B 1 3 2 16S -.56 11 1B 1 3 12 16S -.63 11 1B 1 3 16S -.5 11 1B 1 3 1 16S -.71 11 1B 1 4 1 16S -.72 14 1B 1 4 14S.45 13 1B 1 5 1 16S -.14 22 1B 1 5 13 16S -.65 1 1B 1 5 112 16S -.5 12 1B 1 6 1 16S.5 15 1B 1 6 5 14S.46 16 1B 1 6 1 3 16S -.52 13 1B 1 7 1 16S -.12 24 1B 1 7 5 15S -.62 11 1B 1 7 114 16S -.5 12 1B 1 1 16S -.12 22 1B 1 16S -.7 14 1B 1 16S -.55 11 1B 1 4 15S.42 15 1B 1 1 16S -.7 1 1B 1 1 16S -.61 1 1B 1 5 15S -.64 7 1B 1 7 15S -.62 14 1B 112 1 16S -. 2 1B 112 4 16S.37 11 1B 112 16S.54 1 1B 113 2 16S -. 2 12 1B 113 21 16S -.7 1B 113 73 16S -.5 12 1B 113 76 16S -.63 1 Attachment L-22-211 Page 80 of 89

SG Row Tube TSP INCH %TW 1B 113 2 16S -.6 11 1B 113 1 16S -. 2 1 1B 113 1 3 16S -.57 1B 114 1 16S -.74 1 1B 114 2 16S -.74 1B 114 1 16S -.74 12 1B 114 1 4 16S -.6 12 1B 115 1 16S -.12 1 1B 115 5 16S -.71 11 1B 115 6 16S -.6 11 1B 115 5 16S -.62 1B 115 6 16S -.5 13 1B 115 1 4 16S -.62 1 1B 116 13 16S -. 2 11 1B 116 16S -.5 11 1B 116 1 15S -.64 12 1B 116 1 4 16S -.63 1 1B 116 113 16S -.3 17 1B 117 16S -.6 13 1B 117 16S -.5 11 1B 11 1 16S -.6 12 1B 11 6 16S -.74 11 1B 11 7 16S -.73 15 1B 11 2 16S -.55 11 1B 11 74 16S.33 11 1B 11 76 14S.4 14 1B 11 1 3 16S -.55 1B 11 1 14S -.5 11 1B 11 14 16S -. 1 1B 12 1 16S -.14 17 1B 12 7 16S -.57 1B 12 1 7 14S 21 1B 121 1 16S -.72 11 1B 121 63 16S -.6 13 1B 121 64 16S -.65 12 1B 121 67 16S -.57 1B 121 5 14S -.57 13 1B 121 16S -.54 13 1B 121 1 16S -.5 12 1B 121 7 14S.34 1 1B 121 1 6 13S -.42 1B 121 1 6 14S. 5 15 Attachment L-22-211 Page 81 of 89

SG Row Tube TSP INCH %TW 1B 122 1 11S.64 1B 122 16S -.74 13 1B 122 62 16S -.66 14 1B 122 7 16S -.53 1 1B 122 73 14S.46 15 1B 122 5 16S -.5 14 1B 122 1 5 16S -. 7 26 1B 123 67 16S -.57 11 1B 123 7 16S -.6 15 1B 123 73 16S.26 14 1B 123 74 16S -.57 12 1B 123 75 16S -.55 1 1B 123 16S -.52 14 1B 123 5 16S -.5 13 1B 123 1 16S -.61 16 1B 123 1 4 16S -. 7 2 1B 123 1 4 1S.16 13 1B 124 7 16S -.64 13 1B 124 1 16S -.5 12 1B 124 4 15S -.4 1B 125 1 16S -.6 17 1B 125 17 16S -. 1 15 1B 125 71 16S -.57 1B 125 6 16S -.5 14 1B 126 16S -.6 11 1B 126 7 16S -.57 11 1B 126 73 16S -.57 12 1B 126 77 16S -.64 11 1B 126 7 16S -.52 13 1B 126 7 16S -.54 12 1B 126 6 16S -.54 14 1B 126 16S -.57 13 1B 126 1 16S -.57 15 1B 126 4 16S -.67 15 1B 126 16S -. 7 21 1B 127 6 16S -.6 1B 127 61 16S -.6 1 1B 127 7 16S -.53 11 1B 127 71 16S -.57 13 1B 127 1 16S -.56 1 1B 127 5 16S -.57 12 1B 127 7 16S -.56 14 Attachment L-22-211 Page 82 of 89

SG Row Tube TSP INCH %TW 1B 127 16S -.5 16 1B 127 16S -.5 12 1B 12 6 16S -.6 11 1B 12 72 16S -.55 13 1B 12 7 16S -.54 14 1B 12 1 16S -.14 1 1B 12 61 16S -.57 1 1B 12 73 16S -.52 13 1B 12 76 16S -.54 17 1B 12 7 16S -.54 16 1B 12 7 16S -.54 12 1B 12 3 16S.24 11 1B 12 16S -.57 13 1B 13 57 16S -.6 11 1B 13 64 16S -.55 12 1B 13 73 16S -.54 12 1B 13 74 16S -.54 17 1B 13 2 16S -.56 12 1B 131 4 15S -.7 1B 131 51 15S -.62 13 1B 131 53 16S -.6 11 1B 131 61 16S -.55 1 1B 131 6 16S -.56 11 1B 131 77 16S -.52 16 1B 131 4 16S -.56 1 1B 132 1 16S -.14 24 1B 132 1 16S -. 1 11 1B 132 1 16S.4 11 1B 132 4 16S -.75 1 1B 132 51 16S -.62 1 1B 132 5 16S -.57 11 1B 132 5 16S -.62 12 1B 132 67 16S -.5 13 1B 132 73 16S -.5 1 1B 132 7 16S -. 7 15 1B 132 3 16S -.5 16 1B 132 16S -.55 25 1B 133 2 16S.47 11 1B 133 56 16S -.57 11 1B 133 6 16S -.6 12 1B 133 7 16S -.56 15 1B 133 7 16S -.54 16 Attachment L-22-211 Page 83 of 89

SG Row Tube TSP INCH %TW 1B 133 16S -.12 16 1B 134 1 16S -.16 27 1B 134 7 16S -.11 17 1B 134 44 16S -.66 1B 134 51 16S -.55 12 1B 134 54 16S -.64 1 1B 134 55 16S -.6 1 1B 134 62 16S -.55 14 1B 134 6 16S -.16 15 1B 135 7 15S -.6 11 1B 135 42 16S -.66 1B 135 43 16S -.6 1 1B 135 53 16S -.57 11 1B 135 55 16S -.55 1 1B 135 6 16S -.56 11 1B 135 61 16S -.56 13 1B 135 75 16S -.56 17 1B 135 76 16S -.54 1 1B 135 77 11S -.67 1 1B 136 22 16S -.53 11 1B 136 41 16S -.75 11 1B 136 42 16S -.76 13 1B 136 47 15S -.55 12 1B 136 5 16S -.62 15 1B 136 53 16S -.57 12 1B 136 54 16S -.5 11 1B 136 62 16S -.55 12 1B 136 65 15S -.62 14 1B 137 1 16S -. 7 15 1B 137 45 16S -.73 11 1B 137 7 15S -. 5 1 1B 137 73 16S -.52 12 1B 13 1 16S.4 12 1B 13 15 16S.3 12 1B 13 43 16S -.73 1 1B 13 57 16S -.5 11 1B 13 2 16S.45 16 1B 13 36 16S -.65 12 1B 13 41 16S -.67 1 1B 13 45 16S -.67 11 1B 13 46 16S -.67 11 1B 13 51 16S -.57 11 Attachment L-22-211 Page 84 of 89

SG Row Tube TSP INCH %TW 1B 13 54 16S -.6 13 1B 13 57 16S -.53 15 1B 13 66 16S -.52 1 1B 13 6 16S -.56 11 1B 13 7 16S -.56 1 1B 14 1 16S -. 7 11 1B 14 16 15S.3 15 1B 14 5 16S.2 13 1B 14 66 16S -.56 1 1B 14 6 16S -.55 14 1B 14 7 13S -.53 1B 14 7 12S.57 12 1B 141 1 16S -.16 36 1B 141 4 16S.57 1B 141 7 16S.33 15 1B 141 37 16S -.71 1 1B 141 3 16S -.75 1B 141 45 16S -.67 12 1B 141 46 16S -.57 1 1B 141 52 16S -.57 1 1B 141 53 16S -.56 16 1B 141 57 16S -.53 11 1B 141 5 16S -.56 11 1B 141 6 16S -.5 11 1B 141 6 16S -.52 13 1B 142 1 16S -.73 1B 142 43 16S -.67 14 1B 142 55 16S -.54 11 1B 143 32 16S -.6 15 1B 143 35 16S -.77 12 1B 143 37 16S -.6 14 1B 143 3 16S -.67 13 1B 143 4 16S -.5 14 1B 143 51 16S -.55 15 1B 143 52 16S -.55 13 1B 143 5 16S -.54 16 1B 143 6 16S.37 1 1B 144 1 15S.4 13 1B 144 31 16S -.73 2 1B 144 35 16S -.5 15 1B 144 37 16S -.6 11 1B 145 2 16S.37 13 Attachment L-22-211 Page 85 of 89

SG Row Tube TSP INCH %TW 1B 145 32 16S -.6 15 1B 145 34 15S.4 12 1B 145 34 15S -.51 13 1B 145 4 16S -.65 13 1B 145 42 16S.33 12 1B 145 44 16S -.11 2 1B 145 4 16S -.43 12 1B 145 4 1 S.52 11 1B 146 32 15S.44 16 1B 146 51 1S -.16 15 1B 147 2 16S -.74 11 1B 147 33 16S -.65 14 1B 14 2 16S -.6 15 1B 14 3 16S.35 1 1B 14 4 16S -. 1 1B 14 24 16S -.57 14 1B 14 27 16S -.6 16 1B 14 2 16S -.5 11 1B 14 3 16S -.6 11 1B 14 32 11S -.32 11 1B 14 32 16S -.11 14 1B 15 1 16S -.63 1B 15 23 16S.2 25 1B 15 23 16S -.6 11 1B 15 24 16S.23 27 1B 151 6 16S -.63 1B 151 1 16S -.14 1 1B 151 11 16S -.5 27 1B 151 12 16S -.12 1 1B 151 13 16S.4 1 1B 151 13 1S -.14 12 1B 151 14 16S.42 25 1B 151 14 16S -.71 22

Attachment L-22-211 Page 86 of 89

Wear at Drilled TSPs

SG Row Tube TSP Max Depth Axial Extent Circumferential PDA*

[%TW] [in] Extent [°] [%]

2A 36 1 15S 19 0.31 51.3 2.71 2A 113 4 15S 22 0.31 166.8 10.19 2A 147 12 15S 20 0.36 64.2 3.57 2A 148 20 15S 15 0.27 102.7 4.28 1B 29 1 15S 19 0.38 89.8 4.74 1B 37 114 15S 19 0.29 141.2 7.45 1B 38 115 15S 21 0.29 115.5 6.74 1B 40 117 15S 23 0.31 102.7 6.56 1B 48 123 15S 27 0.29 102.7 7.70

The PDA is conservatively determined as the maximum depth over the entire circumferential extent.

Attachment L-22-211 Page 87 of 89

Section 5

Number of Tubes Plugged During the Inspection Outage for Each Degradation Mechanism (TS 5.6.6.e)

Degradation Mechanism SG 2A SG 1B Wear at broached TSP 14 1

Attachment L-22-211 Page 88 of 89

Section 6

The Number and Percentage of Tubes Plugged to Date, and the Effective Plugging Percentage in Each SG (TS 5.6.6.f)

SG 2A SG 1B Total Tubes Plugged 135 82 217 Percentage Plugged 0.87% 0.53% 0.70%

Attachment L-22-211 Page 89 of 89

Section 7

The Results of Condition Monitoring, Including the Results of Tube Pulls and In-Situ Testing (TS 5.6.6.g)

No degradation was identified that failed to meet condition monitoring criteria. All steam generator performance criteria were met analytically during Cycle 22. As such, in-situ pressure testing was not required, and none was performed. No tube pulls were planned, and none were performed.