ML18149A281

From kanterella
Jump to navigation Jump to search
2017 ATI Environmental Inc. Midwest Laboratory Radiological Environmental Monitoring Program
ML18149A281
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 02/16/2018
From: Grab B
Environmental
To:
FirstEnergy Nuclear Operating Co, Office of Nuclear Reactor Regulation
Shared Package
ML18149A259 List:
References
L-18-092
Download: ML18149A281 (75)


Text

ATI Ei,vironmental, Inc.

/"'\\I Midwest Laborato,-y 1DQ,..-.,Rr>>d*N-,1!.~DIO tJlolo (IU7} ~700

  • faz (IU7J ~517 FINAL REPORT to FIRSTENERGY CORPORATION AKRON, OHIO RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM (REMP) for DAVIS-BESSE NUCLEAR POWER STATION OAK HARBOR, OHIO Prepared and submitted by ENVIRONMENTAL, Inc.

Midwest Laboratory Project No. 8003 Reporting Period: January - December, 2017 Reviewed and Approved by : --,~~-+-,.~i.<>::...M........:;.()..;.,2~t1,=+-, 8

TABLE OF CONTENTS Section List of Tables............................................................................................................... iii

1.0 INTRODUCTION

......................................................................................................... vi 2.0 LISTING OF MISSED SAMPLES................................................................................ vii 3.0 DATA TABULATIONS................................................................................................ viii Appendices A

lnter1aboratory Comparison Program Results........................................................... A-1 B

Data Reporting Conventions..................................................................................... B-1 C

Supplemental Analyses............................................................................................ C-1 ii

LIST OF TABLES 1

Airbome particulates and iodine collected at location T-1, analyses for gross beta and iodine-131............................................................................................................. 1-1 2

Airbome particulates and iodine collected at location T-2, analyses for gross beta and iodine-131............................................................................................................. 2-1 3

Airborne particulates and iodine collected at location T-3, analyses for gross beta and iodine-131............................................................................................................. 3-1 4

Airborne particulates and iodine collected at Location T -4, analyses for gross beta and iodine-131............................................................................................................. 4-1 5

Airborne particulates and iodine collected at Location T-7, analyses for gross beta and iodine-131............................................................................................................. 5-1 6

Airborne particulates and iodine collected at Location T-8, analyses for gross beta and iodine-131............................................................................................................. 6-1 7

Airborne particulates and iodine collected at Location T-9. analyses for gross beta and iodine-131............................................................................................................. 7-1 8

Airborne particulates and iodine collected at Location T-11, analyses for gross beta and iodine-131............................................................................................................. 8-1 9

Airborne particulates and iodine collected at location T-12. analyses for gross beta and iodine-131............................................................................................................. 9*1 10 Airborne particulates and iodine collected at Location T-27, analyses for gross beta and iodine-131........................................................................................................... 10-1 11 Airborne particulate data, gross beta analysis, monthly averages, minima and maxima...................................................................................................................... 11-1 12 Airborne particulate samples. quarter1y composites by location, analyses for strontium-89, strontium-90 and gamma-emitting isotopes......................................... 12-1 13 Area monitors (TlO), quarterty................................................................................................. 13-1 14 Area monitors (fLD), annual.................................................................................................... 14-1 15 Milk. analyses for strontium-89, strontium-90, iodine-131, gamma-emitting isotopes, calcium, stable potassium, and ratios of strontium-90 (pCi) per gram of calcium and cesium-137 (pCi) per gram of potassium................................................................................. 15-1 16 Ground water, analyses for gross beta, tritium, strontium-89 and strontium-90 and gamma-emitting isotopes, quarterty collections,...................................................................... 16-1 17 Domestic meat, analysis for gamma-emitting isotopes............................................................ 17-1 18 Wild meat, analysis for gamma-emitting isotopes.................................................................... 18-1 iii f;7

00 I.O LIST OF TABLES (continued) 19 Green leafy vegetable, analyses for strontium-89, strontium-90, iodine-131 and gamma-emitting isotopes......................................................................................................... 19-1 20 Fruit, analyses for strontium-89, strontium-90, iodine-131 and gamma-emitting isotopes.................................................................................................................................... 20-1 21 Animal-wildlife feed, analysis for gamma-emitting isotopes..................................................... 21-1 22 Soil, analysis for gamma-emitting isotopes.............................................................................. 22-1 23 Treated surface water, monthly composites of weekly grab samples, analysis for gross beta................................................................................................................................ 23-1 24 Treated surface water, quarter1y composites of weekly grab samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes........................................... 24-1 25 Untreated surface water, monthly composites of weekly grab samples, analyses for gross beta, tritium and gamma-emitting isotopes.................................................................... 25-1 26 Untreated surface water, quarter1y composites of weekly grab samples, analyses for strontium-89 and strontium-90................................................................................................. 26-1 27 Fish, analyses for gross beta and gamma-emiltlng isotopes................................................... 28-1 28 Shoreline sediment, analysis for gamma-emitting isotopes..................................................... 29-1 iv

69 LIST OF TABLES (continued}

The following tables are in the Appendices:

Appendix A Attachment A; Acceptance criteria for spiked samples.............................................................. A-2 A-1 lnterlaboratory Comparison Program Results....................................................................... :.. A 1-1 A-2 lnter1aboratory Comparison Program Results, thermoluminescent dosimeters (TLDs)..................................................................................................... A2.-1 A-3 Results of the analyses on in-house spiked samples.............................................................. A3-1 A-4 Results of the analyses on in-house ft blank" samples.............................................................. A4-1 A-5 Results of the analyses on in-house ftduplicate* samples........................................................ A5-1 A-6 Mixed Analyte Performance Evaluation Program (MAPEP)..................................................... AS-1 A-7 Environmental Resources Associates, Crosscheck Program Results (EML study replacement).............................................................................................................. A 7 -1 Appendix B B-1 Data Reporting Conventions...................................................................................................... B-2 V

0 r--

1.0 INTRODUCTION

The following constitutes the final 2017 Monthly Progress Report for the Radiological Environmental Monitoring Program conducted at the Davis-Besse Nuclear Power Station in Oak Harbor, Ohio. Results of completed analyses are presented in the attached tables.

All activities, except gross alpha and gross beta, are decay corrected to the time of collection.

All samples were collected within the scheduled period unless noted otherwise in the Listing of Missed Samples.

vi 7(,')

r--

Sample Type WW WW TLD TLD WW WW TLD TLD Location T-226 T-226 T-49 T-222 T-226 T-226 T-49 T-222 7,

2.0 USTING OF MISSED SAMPLES Expected Collection Reason Date 03-29-17 Sample not received.

05-17-17 Sample not received.

2nd Qtr 2017 TLD missing in field.

2nd Ctr 2017 TLD missing in field.

07-19-17 Sample not received.

10-17-17 Sample not received.

Annual TLD missing in field.

Annual TLO missing in field.

vii

7) 3.0 DATA TABULATIONS viii

Table 1. Airborne particulates and charcoal canisters, analyses for gross beta and iodina..131 1

Location: T-1 Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m")

Gross Beta Collected (m")

Gross Beta Required LLD 0.010 0,010 01-10-17 282 0.020 :t 0.004 07-05-17 336 0.022 :t 0.003 01-17-17 284 0.033 :t 0.004 07-11-17 243 0.022 +/- 0.004 01-24-17 283 0.016 :t0.003 07-18-17 289 0.022 :t 0.003 01-31-17 283 0.026 :t 0.004 07-25-17 284 0.025 :t 0.004 08-01-17 293 0.021 :t 0.003 02-07-17 283 0.027 :t 0.004 02-14-17 284 0.026 :t 0.004 08-08-17 288 0.034 :t 0.004 02-21-17 283 0.026 :t 0.004 ° 08-15-17 291 0.030 :t 0.004 02-28-17 283 0.025 +/- 0.004 08-22-17 291 0.036 :t 0.004 08-29-17 290 0.023 :t 0.003 03-07-17 284 0.020 :t 0.004 03-14-17 282 0.020 :t 0.003 09-05-17 280 0.033 +/- 0.004 03-21-17 283 0.027 :t 0.004 09-12-17 283 0.018 :t 0.003 03-28-17 283 0.022 :t 0.004 09-19-17 282 0.034 :t 0.004 09-26-17 282 0.056 +/- 0.005 10-03-17 282 0.038 :t 0.004 1st Quarter Mean :t s.d.

0.024 :t 0.005 3rd Quarter Mean :t s.d.

0.030

t 0.010 04-04-17 284 0.012 :t 0.003 10-03-17 282 0.038 :t 0.004 04-11-17 283 0.014 :t 0.003 10-10-17 282 0.033 :t 0.004 04-18-17 284 0.023 :t 0.004 10-17-17 284 0.028 :t 0.004 04-25-17 284 0.019 :t 0.003 10-24-17 284 0.041 +/- 0.004 05-02-17 284 0.014 :t 0.003 10-31-17 280 0.016 :t 0.003 05-09-17 282 0.014 :t 0.003 11-07-17 282 0.028 :t 0.004 05-16-17 285 0.013 :t 0.003 11-14-17 282 0.030 +/- 0.004 05-23-17 283 0.021 :t 0.003 11-21-17 282 0.035 :t 0.004 05-30-17 283 0.016 :t 0.003 11-28-17 282 0.031 :t 0.004 06-07-17 324 0.018 :t 0.003 12-05-17 282 0.036 +/-0.004 06-13-17 243 0.023 :t 0.004 12-12-17 282 0.040 :t 0.004 06-20-17 284 0.025 :t 0.004 12-19-17 282 0.032 :t 0.004 06-27-17 290 0.014 :t 0.003 12-26-17 282 0.035 :t 0.004 01-02-18 282 0.042 :t 0.004 2nd Quarter Mean :t s.d.

0.017 +/- 0.004 4th Quarter Mean +/- s.d.

0.033 +/- 0.007 Cumulative Average 0.026

  • lodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.

0 Two air samples labeled T-11; none labeled T-1. Beta results are similar.

1-1

74 Table 2. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 1.

Location: T-2 Units: pCi/m3 Collection: Continuous, weekly exchange. '

Date Volume Date Volume Collected (m"')

Gross Beta Collected (m"')

Gross Beta Required LLD 0.010 0.010 01-10-17 280 0.022 :1: 0.004 07-05-17 321 0.022 :t 0.003 01-17-17 281 0.036 :t 0.004 07-11-17 246 0.019 +/- 0.004 01-24-17 280 0.016 +/- 0.003 07-18-17 281 0.020 :t 0.003 01-31-17 280 0.023 :1: 0.004 07-25-17 281 0.030 :t: 0.004 08-01-17 278 0.020 +/- 0.003 02-07-17 280 0.026 +/- 0.004 02-14-17 281 0.023 :1: 0.004 08-08-17 287 0.030 :1: 0.004 02-21-17 280 0.021 :t 0.004 08-15-17 284 0.032 :I: 0.004 02-28-17 280 0.025 :t 0.004 08-22-17 284 0.037 :t 0.004 08-29-17 287 0.024 :t 0.004 03-07-17 289 0.022 :t 0.004 03-14-17 288 0.016 +/- 0.003 09-05-17 277 0.025 :t 0.004 03-21-17 289 0.026 :t: 0.004 09-12-17 284 0.015 :t 0.003 03-28-17 289 0.022 :t: 0.003 09-19-17 284 0.032 :t 0.004 09-26-17 283 0.047 +/- 0.005 10-03-17 286 0.034 :t 0.004 1st Quarter Mean :1: s.d.

0.023 :t 0.005 3rd Quarter Mean :t: s.d.

0.028 :t 0.009 04-04-17 290 0.018 :t 0.003 10-03-17 286 0.034 :t 0.004 04-11-17 289 0.015 :t:0.003 10-10-17 296 0.034 :t: 0.004 04--18-17 289 0.020 :t 0.004 10-17-17 294 0.028 :t 0.004 04--25-17 289 0.016 :t 0.003 10-24-17 292 0.039 :I: 0.004 05-02-17 289 0.020 :I: 0.003 10-31-17 287 0.016 :t 0.003 05-09-17 288 0.019 :t 0.003 11-07-17 295 0.026 :t 0.004 05-16-17 291 0.018 :t 0.003 11-14-17 292 0.030 :t 0.004 05-23-17 288 0.029 :t 0.004 11-21-17 285 0.036 :t 0.004 05-30-17 289 0.019 :t 0.003 11-28-17 286 0.033 :t: 0.004 06-07-17 331 0.022 :t: 0.003 12-05-17 286 0.038 :t: 0.004 06-13-17 247 0.029 :t 0.004 12-12-17 286 0.034 :t 0.004 06-20-17 290 0.028 :t 0.004 12-19-17 286 0.032 :t 0.004 06-27-17 289 0.023 t 0.004 12-26-17 286 0.036 :t: 0.004 01-02-18 286 0.047 +/- 0.004 2nd Quarter Mean :t s.d.

0.021 :I: 0.005 4th Quarter Mean :t s.d.

0.033 :t: 0.007 Cumulative Average 0.026

  • iodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.

2-1

75 Table 3. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-1318

  • Location: T-3 U11il:;. µCi/m:\\

Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m~

Gross Beta Collected (m~

Gross Beta Required LLD 0,010 0.010 01-10-17 287 0.028 :t 0.004 07-05-17 323 0.022 :i: 0.003 01-17-17 281 0.038 +/- 0.004 07-11-17 251 0.020 :t 0.004 01-24-17 287 0.019 :t 0.003 07-18-17 287 0.026 :t 0.004 01-31-17 287 0.028 :t 0.004 07-25-17 287 0.027 :i: 0.004 08-01-17 280 0.019 :t 0.003 02-07-17 287 0.032 +/- 0.004 02-14-17 288 0.027 :i: 0.004 08-08-17 289 0.028 :t: 0.004 02-21-17 287 0.025 +/- 0.004 08-15-17 290 0.035 :t 0.004 02-28-17 287 0.029 :t 0.004 08-22-17 289 0.035 :t 0.004 08-29-17 292 0.026 :i: 0.004 03-07-17 286 0.024 :t 0.004 03-14-17 284 0.022 :t 0.004 09-05-17 286 0.031 :t: 0.004 03-21-17 285 0.022 :t 0.004 09-12-17 289 0.012 :t 0.003 03-28-17 286 0.024 :i: 0.004 09-19-17 289 0.035 :t 0.004 09-26-17 289 0.059 :t 0.005 10-03-17 289 0.036 :t 0.004 1st Quarter Mean +/- s.d.

0.027 :t 0.005 3rd Quarter Mean t s.d.

0.029 :t 0.011 04-04-17 286 0.015 :t 0.003 10-03-17 289 0.036 :t 0.004 04-11-17 285 0.017 :t 0.003 10-10-17 289 0.031 :t 0.004 04-18-17 286 0.021 :t 0.004 10-17-17 289 0.029 :t 0.004 04-25-17 286 0,018 :t:0.003 10-24-17 291 0.039 :t 0.004 05-02-17 286 0.015 :t 0.003 10-31-17 286 0.016 :t 0.003 05-09-17 285 0.016 +/- 0.003 11--07-17 289 0.025 :t 0.004 05-16-17 288 0.015 :t 0.003 11-14-17 291 0.033 :t 0.004 05-23-17 285 0.020 :t: 0.003 11-21-17 288 0.027 :t: 0.004 05-30-17 285 0.018 +/-0.003 11-28-17 290 0.032 :1: 0.004 06-07-17 327 0.022 +/- 0.003 12-05-17 289 0.038 :t 0.004 06-13-17 244 0.025 :t 0.004 12-12-17 290 0.034 :t: 0.004 06-20-17 286 0.024 :t 0.004 12-19-17 289 0.032 :t 0.004 06-27-17 285 0.015 +/- 0.003 12-26-17 290 0.039 :t 0.004 01-02-18 289 0.040 :t 0.004 2nd Quarter Mean+/- s.d.

0.019 :t 0.004 4th Quarter Mean :t s.d.

0.032 :t 0.007 Cumulative Average 0.027

  • lodine-131 concentrations are < 0.07 pCi/m3 unless noted otherwise.

3-1

76 Table 4. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 1.

Location: T -4 Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m")

Gross Bela Collected (m")

Gross Beta Required LLD 0.010 0.010 01-10-17 289 0.020 :t: 0.004 07--05--17 325 0.023 +/- 0.003 01-17-17 290 0.033 :I: 0.004 07-11-17 252 0.024 +/- 0.004 01-24-17 289 0.019 +/- 0.003 07-18-17 286 0.024 +/- 0.004 01-31-17 289 0.023 :t: 0.004 07-25--17 295 0.025 :t: 0.004 08-01-17 284 0.020 +/- 0.003 02-07-17 289 0.027 :t: 0.004 02-14-17 286 0.027 ;t 0.004 08-08-17 291 0.027 :t 0.004 02-21-17 287 0.024 +/- 0.004 08-15-17 288 0.033 :t 0.004 02-28-17 289 0.033 :t: 0.004 08-22-17 287 0.037 +/- 0.004 08-29-17 273 0.022 :t: 0.004 03-07-17 188 0.040 :I: 0.006 03-14-17 272 0.024 :t 0.004 09-05-17 276 0.031 :I: 0.004 03-21-17 286 0.029 :t 0.004 09-12-17 279 0.014 +/- 0.003 03-28-17 287 0.024 +/- 0.004 09-19-17 279 0.037 :t: 0.004 09-26-17 279 0.056 :t: 0.005 10-03-17 279 0.035 :t: 0.004 1st Quarter Mean +/- s.d.

0.027 +/- 0.006 3rd Quarter Mean +/- s.d.

0.029 +/- 0.010 04-04-17 288 0.015 :t 0.003 10-03--17 279 0.035 :t: 0.004 04-11-17 287 0.017 :I: 0.003 10-10-17 279 0.034 :t: 0.004 04-18-17 287 0.020 +/- 0.004 10-17-17 288 0.027 +/- 0.004 04-25--17 287 0.020 :t: 0.003 10-24-17 285 0.040 +/- 0.004 05-02-17 287 0.014 :t 0.003 10-31-17 277 0.015 :t: 0.003 05-09-17 286 0.016 :1: 0.003 11-07-17 279 0.026 +/- 0.004 05-16-17 289 0.015 +/- 0.003 11-14-17 280 0.032 +/- 0.004 05-23-17 286 0.022 :t: 0.003 11-21-17 287 0.030 +/- 0.004 05--30-17 286 0.017 :t 0.003 11-28-17 289 0.036 :t: 0.004 06--07-17 329 0.021 +/- 0.003 12--05-17 279 0.035 +/- 0.004 06-13-17 245 0.027 :t 0.004 12-12-17 279 0.032 :t: 0.004 06-20-17 288 0.023 +/- 0.004 12-19-17 278 0.030 +/- 0.004 06-27-17 287 0.015 :t 0.003 12-26-17 280 0.034 :t 0.004 01-02-18 279 0.042 :I: 0.004 2nd Quarter Mean :t s.d.

0.019 +/- 0.004 4th Quarter Mean +/- s.d.

0.032 :t: 0.007 Cumulative Average 0.027

  • ioctine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.

4-1

r--

r--

77 Table 5. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131*.

Location: T-7 Units: pCllm' Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m3>

Gross Beta Collected (m3)

Gross Bela Required LLD 0.010 0.010 01-10-17 286 0.020 +/- 0.004 07-05-17 326 0.024 :t 0.003 01-17-17 287 0.029 :t 0.004 07-11-17 236 0.025 :t 0.004 01-24-17 285 0.018 +/- 0.003 07-18-17 281 0.025 +/- 0.004 01-31-17 286 0.022 :t 0.004 07-25-17 286 0.023 +/- 0.004 08-01-17 296 0.022 +/- 0.003 02--07-17 287 0.022 +/- 0.004 02-14-17 286 0.023 +/- 0.004 08-08-17 288 0.031 +/- 0.004 02-21-17 283 0.022 :1: 0.004 08-15-17 286 0.033 +/- 0.004 02-28-17 284 0.025 +/- 0.004 08-22-17 286 0.036 :t 0.004 08-29-17 290 0.024 :t 0.004 03-07-17 284 0.021 :t 0.004 03-14-17 274 0.023 +/- 0.004 09-05-17 285 0.032 :I: 0.004 03-21-17 278 0.027 :t 0.004 09-12-17 287 0.014 :t 0.003 03-28-17 284 0.025 :t 0.004 09-19-17 285 0.036 :t 0.004 09-26-17 286 0.058 :t 0.005 10-03-17 287 0.038 +/- 0,004 1st Quarter Mean :t s.d.

0.023 :t 0.003 3rd Quarter Mean +/- s.d.

0.030 :t 0.010 04--04-17 284 0.015 :t 0.003 10-03-17 287 0.038 :t 0.004 04-11-17 283 0.017 +/- 0.003 10-10-17 291 0.038 :t 0.004 04-18-17 291 0.023 :t 0.004 10-17-17 284 0.030 :t 0.004 04-25-17 278 0.017 :t 0.003 10-24-17 285 0.045 :t 0.005 05-02-17 283 0.015 :t 0.003 10-31-17 285 0.019 t0.003 05-09-17 284 0.014 :t 0.003 11--07-17 286 0.026 +/- 0.004 05-16-17 284 0.013 :t 0.003 11-14-17 285 0.036 :t: 0.004 05-23-17 284 0.026 :t 0.004 11-21-17 286 0.030 ::I: 0.004 05-30-17 283 0.021 :t 0.003 11-28-17 286 0.033 :t 0.004 06-07-17 324 0.024 :t: 0.003 12-05-17 286 0.039 ;1; 0.004 06-13-17 244 0.026 :t 0.004 12-12-17 364 0.024 :t 0.003 06-20-17 283 0.026 +/- 0.004 12-19-17 286 0.029 +/- 0.004 06-27-17 284 0.016 :t 0.003 12-26-17 289 0.034 +/- 0.004 01--02-18 289 0.040 +/- 0.004 2nd Quarter Mean :t s.d.

0.019 :t: 0.005 4th Quarter Mean +/-: s.d.

0.033 :t 0.007 Cumulative Average 0.027

  • lodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.

5-1

00 r--

78 Table 6. Airbome particulates and charcoal canisters, analyses for gross beta and iodine-131*.

Location: r.a Units: pCilm3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m3>

Gross Bela Collected (m3>

Gross Beta Required LLD 0.010 0.010 01.10-11 291 0.025 +/- 0.004 07--05--17 348 0.021 +/- 0.003 01-17*17 291 0.032 :t 0.004 07-11*17 233 0.025 :t 0.004 01-24--17 289 0.016 :t 0.003 07-18-17 285 0.022 :t 0.003 01.31.17 291 0.019 :t 0.003 07-25-17 293 0.028 :t 0.004 08-01-17 293 0.017 :t 0.003 02-07-17 291 0.025 :t 0.004 02-14--17 296 0.026 :t 0.004 08-08-17 285 0.032 :t 0.004 02-21-17 284 0.025 :t 0.004 08-15-17 286 0.030 :t 0.004 02*28-17 304 0.024 :t 0.004 08-22-17 286 0.038 :t 0.004 06-29-17 297 0.026 :t 0.004 03-07-17 304 0.022 :t 0.003 03-14*17 293 0.021 :t 0.003 09----05-1 7 273 0.033 :t 0.004 03--21-17 297 0.026 :t 0.004 09-12-17 287 0.013 +/- 0.003 03--28-17 303 0.020 +/- 0.003 09-19-17 285 0.037 :t 0.004 09-26-17 286 0.052 :t 0.005 10--03--17 295 0.036 +/- 0.004 1st Quarter Meant s.d.

0.023 t 0.004 3rd Quarter Mean :t s.d.

0.029 :t 0.010 04--04--17 304 0.014 +/- 0.003 10--03-17 295 0.036 :t 0.004 04-11-17 302 0.014 :t 0.003 10-10-17 290 0.029 :t 0.004 04-18-17 310 0.017 :t 0.003 10-17-17 288 0.025 :t 0.004 04-25-17 303 0.019 :t 0.003 10-24-17 284 0.044 :t 0.005 05-02-17 297 0.015 :t 0.003 10-31-17 293 0.016 :t 0.003 05---09-17 304 0.016 :t 0.003 11-07-17 292 0.026 :t 0.004 05--16-17 304 0.014 :t 0.003 11-14--17 283 0.032 :t 0.004 05-23-17 303 0.019 t 0.003 11-21-17 284 0.030 :t 0.004 05-30-17 302 0.017 :t 0.003 11-28-17 284 0.036 :t 0.004 06--07-17 346 0.020 :t 0.003 12-05-17 289 0.035 :t 0.004 06--13--17 261 0.033 :t 0.004 12-12-17 279 0.038 :t 0.004 06-20-17 303 0.023 +/- 0.003 12-19-17 285 0.032 :t 0.004 06-27-17 304 0.015 :t 0.003 12-26-17 284 0.038 :t 0.004 01--02-18 284 0.045 :t 0.004 2nd Quarter Mean :t s.d.

0.01 a t 0.005 4th Quarter Mean :t s.d.

0.033 t 0.008 Cumulative Average 0.026

  • iodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.

6-1

Table 7. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131*.

Location: T-9 (C)

Unill;. µCi/111:1 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (mj Gross Beta Collected (m~

Gross Beta Required LLD 0,010 0,010 01-10-17 287 0.008 :t 0.003 t>

07-05-17 321 0.020 :t 0.003 01-17-17 287 0.034 :t: 0.004 07-1M7 246 0.021 :t: 0.004 01-24-17 285 0.019 :t: 0.003 07-18-17 286 0.022 :t: 0.003 01-31-17 277 0.025 :t: 0.004 07-25-17 286 0.024 :t 0.004 08-01-17 286 0.019 :t 0.003 02-07-17 297 0.025 :t 0.004 02-14-17 277 0.027 :t: 0.004 08-08-17 296 0.027 :t: 0.004 02-21-17 289 0.024 :t 0.004 08-15-17 287 0.027 :t: 0.004 02-28-17 275 0.022 :t: 0.004 08-22-17 289 0.033 :t: 0.004 08-29-17 281 0.024 :t: 0.004 03-07-17 287 0.023 :t: 0.004 03-14-17 295 0.017 :t 0.003 09-05-17 282 0.028 :t 0.004 03-21-17 287 0.025 :t 0.004 09-12-17 298 0.014 :t 0.003 03-28-17 287 0.022 :t 0.004 09-19-17 277 0.027 :t: 0.004 09-26-17 288 0.049 :t: 0.005 10-03-17 294 0.033 :t 0.004 1st Quarter Mean :t s.d.

0.023 :t 0.006 3rd Quarter Mean :t s.d.

0.026 :t: 0.008 04-04-17 287 0.016 :t 0.003 10-03-17 294 0.033 :t 0.004 04-11-17 277 0.017 :t: 0.003 10-10-17 291 0.031 :t: 0.004 04-18-17 297 0.022 :t 0.004 10-17-17 284 0.031 :t 0.004 04-25-17 285 0.019 :t 0.003 10-24-17 281 0.044 :t: 0.005 05-02-17 279 0.018 :t 0.003 10-31-17 287 0.014 :t 0.003 05-09-17 298 0.015 :t: 0.003 11-07-17 297 0.029 :t: 0.004 05-16-17 288 0.015 :t 0.003 11-14-17 277 0.034 :t 0.004 05-23-17 286 0.023 t 0.004 11-2M7 286 0.034 :t 0.004 05-30-17 277 0.018 :t 0.003 11-28-17 286 0.034 :t 0.004 06-07-17 328 0.015 :t 0.003 12-05-17 293 0.037 :t 0.004 06-13-17 257 0.025 :t: 0.004 12-12-17 279 0.037 :t: 0.004 06-20-17 277 0.029 :t: 0.004 12-19-17 296 0.035 :t: 0.004 06-27-17 298 0.014 :t: 0.003 12-26-17 287 0.036 :t 0.004 01-02-18 284 0.041 :t 0.004 2nd Quarter Mean :t: s.d.

0.019 :t: 0.005 4th Quarter Mean :t s.d.

0.034 +/- 0.007 Cumulative Average 0.026

  • rodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.

b Filter light.

7-1

0 00 Table 8. Airbome particulates and charcoal canisters, analyses for gross beta and iodine-131 1.

Location: T-11 (C)

Units: pCl/m, Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m"')

Gross Beta Collected (m~

Required LLD 0.010 01-10-17 292 0.021 :t 0.004 07-05-17 324 01-17-17 293 0.037 :t 0.004 07-11-17 237 01-24-17 291 0.018 :t 0.003 07-18-17 277 01-31-17 292 0.026 :t 0.004 07-25-17 278 08-01-17 283 02-07-17 292 0.024 :t:: 0.004 02-14-17 292 0.028 :t 0.004 06-08-17 285 02-21-17 292 0.025 :t 0.004 b 06-15-17 287 02-28-17 292 0.029 +/- 0.004 06-22-17 287 06-29-17 287 03-07-17 292 0.023 :t 0.004 03-14-17 291 0.017 :I: 0.003 09-05-17 287 03-21-17 291 0.029 :t 0.004 09-12-17 287 03-28-17 280 0.020 :t 0.003 09-19-17 287 09-26-17 287 10-03-17 287 1st Quarter Mean :t s.d.

0.025 :t 0.006 3rd Quarter Mean :t s.d.

04-04-17 281 0.014 :t 0.003 10-03-17 287 04-11-17 280 0.016 :t 0.003 10-10-17 287 04-16-17 281 0.024 :t: 0.004 10-17-17 287 04-25-17 280 0.016 :t 0.003 10-24-17 287 05-02-17 280 0.012 :t 0.003 10-31-17 287 05-09-17 280 0.010 :t 0.003 11-07-17 287 05-16-17 281 0.016 :t 0.003 11-14-17 287 05-23-17 280 0.022 :t 0.004 11-21-17 287 05-30-17 280 0.016 :t 0.003 11-28-17 287 06-07-17 320 0.019 :t 0.003 12-05-17 287 06-13-17 240 0.029 :t 0.004 12-12-17 287 06-20-17 280 0.023 :I: 0.004 12-19-17 287 06-27-17 280 0.018 :t 0.003 12-26-17 287 01-02-18 235 2nd Quarter Mean :t s.d.

0.018 :t 0.005 4th Quarter Mean :t s.d.

Cumulative Average

  • iodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.

bTwo air samples labeled T-11; none labeled T-1. Beta results are similar.

8--1 Gross Bela 0.010 0.023 :t 0.003 0.022 :t 0.004 0.025 :t 0.004 0.028 :t 0.004 0.021 +/- 0.003 0.034 :t 0.004 0.033 :t 0.004 0.038 :t:: 0.004 0.026 :t 0.004 0.028 :t 0.004 0.017 :t 0.003 0.039 :t 0.004 0.0S5 :t 0.005 0.034 :t 0.004 0.030 :t 0.010 0.034 :t 0.004 0.033 :t 0.004 0.030 :t 0.004 0.042 :t 0.004 0.019 :t0.003 0.028 :t 0.004 0.034 :t 0.004 0.033 :t 0.004 0.040 :t 0.004 0.036 :t 0.004 0.037 :t 0.004 0.033 :t 0.004 0.039 :t 0.004 0.043 :t 0.005 0.034 +/- 0.006 0.027

00 Table 9. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-1318.

Location: T-12 (C)

Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m")

Gross Beta Collected (m")

Gross Beta Required LLD 0.010 0,010 01-10-17 281 0.017 +/- 0.004 07-05-17 330 0.027 +/- 0.003 01-17-17 283 0.036 :t 0.004 07-11-17 246 0.018 :t 0.004 01-24-17 281 0.021 :t: 0.004 07-18-17 284 0.023 :t: 0.004 01-31-17 281 0.023 :t: 0.004 07-25-17 287 0.022 :t 0.003 08-01-17 297 0.021 +/- 0.003 02-07-17 281 0.027 +/- 0.004 02-14-17 283 0.027 :1: 0.004 08-08-17 291 0.030 :t 0.004 02-21-17 281 0.022 :t: 0.004 08-15-17 297 0.031.t 0.004 02-28-17 282 0.027 :t 0.004 08-22-17 276 0.026 :t 0.004 08-29-17 284 0.025 :I:: 0.004 03-07-17 281 0.022 :t 0.004 03-14-17 280 0.025 :t 0.004 09-05-17 280 0.033 :t 0.004 03-21-17 281 0.022 :t 0.004 09-12-17 276 0.016 :t 0.003 03-28-17 285 0.021 +/- 0.003 09-19-17 277 0.031 :1: 0.004 09-26-17 276 0.056 :t 0.005 10-03-17 278 0.026 :t 0.004 1st Quarter Mean :I: s.d.

0.024 :1: 0.005 3rd Quarter Mean :t s.d.

0.028 :t 0.010 04-04-17 288 0.014 :t 0.003 10-03-17 278 0.026 :t 0.004 04-11-17 286 0.017 :t 0.003 10-10-17 285 0.029 :t 0.004 04-18-17 286 0.019 :t 0.004 10-17-17 285 0.028 :t 0.004 04-25-17 288 0.013 :t 0.003 10-24-17 287 0.042 :t 0.004 05-02-17 284 0.014 :t 0.003 10-31-17 276 0.017 :t 0.003 05-09-17 284 0.013 :t 0.003 11-07-17 286 0.025 :t 0.004 05-16-17 289 0.019 :t: 0.003 11-14-17 276 0.034 :t 0.004 05-23-17 285 0.023 :t 0.004 11-21-17 276 0.034 :I:: 0.004 05-30-17 285 0.014 :t 0.003 11-28-17 277 0.037 :t 0.004 06-07-17 328 0.020 :t 0.003 12-05-17 279 0.032 :t 0.004 06-13-17 244 0.025 :t 0.004 12-12-17 284 0.030 :t 0.004 06-20-17 287 0.025 :t 0.004 12-19-17 285 0.029 +/- 0.004 06-27-17 285 0.016 :t 0.003 12-26-17 287 0.032 :t 0.004 01-02-18 286 0.033 :t 0.004 2nd Quarter Mean :t s.d.

0.018 :t:0.004 4th Quarter Mean :t s.d.

0.031 :t 0.006 Cumulative Average 0.025

  • lodine--131 concentrations are < 0.07 pCi/m3 unless noted otherwise.

9-1

N 00 Table 10. Ail'bome particulates and charcoal canisters. analyses for gross beta and iodine-131 *.

Location: T-27 {C)

Uriil:.. µCi/111~

Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected

{mj Gross Beta Collected (m")

Gross Beta Required LLD 0.010 0.010 01-10-17 286 0.022 :t 0.004 07-05-17 328 0.023 +/- 0.003 01-17-17 287 0.036 :t 0.004 07-11-17 252 0.028 +/- 0.004 01-24-17 286 0.017 :t 0.003 07-18--17 288 0.021 +/- 0.003 01-31-17 285 0.025 +/- 0.004 07-25-17 292 0.024 :t 0.004 08--01-17 303 0.022 +/- 0.003 02-07-17 285 0.032 :t 0.004 02-14-17 287 0.028 +/- 0.004 08-08--17 285 0.032 :t 0.004 02-21-17 285 0.025 +/- 0.004 08--15-17 290 0.031 +/- 0.004 02-28--17 286 0.029 :t 0.004 08--22-17 289 0.033 +/- 0.004 08--29-17 46 0.001 +/- 0.012 b 03-07-17 285 0.024 :t 0.004 03-14-17 271 0.021 +/- 0.004 09-05-17 289 0.026 :t 0.004 03-21-17 285 0.027 :t 0.004 09-12-17 283 0.017 +/- 0.003 03-28-17 285 0.026 +/- 0.004 09-19-17 284 0.037 :t 0.004 09-26-17 283 0.052 +/- 0.005 10-03-17 285 0.037 :t 0.004 1st Quarter Mean :t s.d.

0.026 +/- 0.005 3rd Quarter Mean :t s.d.

0.027 +/- 0.012 04-04-17 287 0.015 +/- 0.003 10-03-17 285 0.037 +/- 0.004 04-11-17 286 0.017 :t 0.003 10-10--17 282 0.030 +/- 0.004 04-18--17 289 0.023 :t 0.004 10-17-17 278 0.028 :t 0.004 04-25-17 291 0.017 :t 0.003 10--24-17 294 0.036 +/- 0.004 05-02-17 286 0.012 :t 0.003 10-31-17 282 0.015 +/- 0.003 05-09-17 288 0.016 :t 0.003 11-07-17 283 0.031 +/- 0.004 05-16-17 292 0.017 :t 0.003 11-14-17 284 0.035 +/- 0.004 05-23-17 288 0.021 :t 0.003 11-21-17 283 0.031 +/- 0.004 05-30--17 288 0.018 :t 0.003 11-28--17 284 0.033 :t 0.004 06-07-17 331 0.023 :t 0.003 12-05-17 286 0.038 :t 0.004 06-13-17 247 0.027 :t 0.004 12-12-17 282 0.034 :t 0.004 06-20-17 290 0.024 :t 0.004 12-19-17 282 0.034 :t 0.004 06-27-17 288 0.016 +/- 0.003 12-26-17 284 0.042 :t 0.004 01-02-18 284 0.045 :t 0.004 2nd Quarter Mean :t s.d.

0.019 :t 0.004 4th Quarter Mean :t s.d.

0.034 +/- 0.007 Cumulative Average 0.027 8 lodine---131 concentrations are< 0.07 pCi/m3 unless noted otherwise.

b Low volume due to blown fuse: 1-131 result= 0.08 pCi/m3 due to low volume.

10- 1

(Y) 00 8]

Table 11-1. Airborne particulate data.gross beta analyses, monthly averages. minima and maxima.

Janua~

A ril Location Average Minima Maxima Location Average Minima Maxima T-9 0.022 0.008 0.034 T-9 0.018 0.016 0.022 T-11 0.026 0.018 0.037 T-11 0.016 0.012 0.024 T-12 0.024 0.017 0.036 T-12 0.015 0.013 0.019 T-27 0.025 0.017 0.036 T-27 0.017 0.012 0.023 Controls 0.024 0.008 0.037 Controls 0.017 0.012 0.024 T-1 0.024 0.016 0.033 T-1 0.016 0.012 0.023 T-2 0.024 0.016 0.036 T-2 0.018 0.015 0.020 T-3 0.028 0.019 0.038 T-3 0.017 0.015 0.021 T-4 0.024 0.019 0.033 T-4 0.017 0.014 0.020 T-7 0.022 0.018 0.029 T-7 0.017 0.015 0.023 T-8 0.023 0.016 0.032 T-8 0.016 0.014 0.019 Indicators 0.024 0.016 0.038 Indicators 0.017 0.012 0.023 Februa~

Mai Location Average Minima Maxima Location Average Minima Maxima T-9 0.025 0.022 0.027 T-9 0.018 0.015 0.023 T-11 0.027 0.024 0.029 T-11 0.016 0.010 0.022 T-12 0.026 0.022 0.027 T-12 0.017 0.013 0.023 T-27 0.029 0.025 0.032 T-27 0.018 0.016 0.021 Controls 0.027 0.022 0.032 Controls 0.017 0.010 0.023 T-1 0.026 0.025 0.027 T-1 0.016 0.013 0.021 T-2 0.024 0.021 0.026 T-2 0.021 0.018 0.029 T-3 0.028 0.025 0.032 T-3 0.017 0.015 0.020 T-4 0.028 0.024 0.033 T-4 0.018 0.015 0.022 T-7 0.023 0.022 0.025 T-7 0.019 0.013 0.026 T-8 0.025 0.024 0.026 T-8 0.017 0.014 0.019 Indicators 0.026 0.021 0.033 Indicators 0.018 0.013 0.029 March June Location Averaae Minima Maxima Location Averaae Minima Maxima T-9 0.022 0.017 0.025 T-9 0.021 0.014 0.029 T-11 0.022 0.017 0.029 T-11 0.022 0.018 0.029 T-12 0.023 0.021 0.025 T-12 0.022 0.016 0.025 T-27 0.025 0.021 0.027 T-27 0.023 0.016 0.027 Controls 0.023 0.017 0.029 Controls 0.022 0.014 0.029 T-1 0.022 0.020 0.027 T-1 0.020 0.014 0.025 T-2 0.022 0.016 0.026 T-2 0.026 0.022 0.029 T-3 0.023 0.022 0.024 T-3 0.022 0.015 0.025 T-4 0.029 0.024 0.040 T-4 0.022 0.015 0.027 T-7 0.024 0.021 0.027 T-7 0.023 0.016 0.026 T-8 0.022 0.020 0.026 T-8 0.023 0.015 0.033 Indicators 0.024 0.016 0.040 Indicators 0.023 0.014 0.033 Note: Unless otherwise specified, samples collected on the first, second or third day of the month are grouped with data from the previous month.

11-1

84 Table 11-1. Airborne particulate data.gross beta analyses, monthly averages, minima and maxima.

Jul October Location Average Minima Maxima Location Average Minima Maxima T-9 0.021 0.019 0.024 T-9 0.031 0.014 0.044 T-11 0.024 0.021 0.028 T-11 0.032 0.019 0.042 T-12 0.022 0.018 0.027 T-12 0.028 0.017 0.042 T-27 0.024 0.021 0.028 T-27 0.029 0.015 0.037 Controls 0.023 0.018 0.028 Controls 0.030 0.014 0.044 T-1 0.022 0.021 0.025 T-1 0.031 0.016 0.041 T-2 0.022 0.019 0.030 T-2 0.030 0.016 0.039 T-3 0.023 0.019 0.027 T-3 0.030 0.016 0.039 T-4 0.023 0.020 0.025 T-4 0.030 0.015 0.040 T-7 0.024 0.022 0.025 T-7 0.034 0.019 0.045 T-8 0.023 0.017 0.028 T-8 0.030 0.016 0.044 Indicators 0.023 0.017 0.030 Indicators 0.031 0.015 0.045 August November Location Average Minima Maxima Location Average Minima Maxima T-9 0.028 0.024 0.033 T-9 0.033 0.029 0.034 T-11 0.033 0.026 0.038 T-11 0.034 0.028 0.040 T-12 0.028 0.025 0.031 T-12 0.033 0.025 0.037 T-27 0.024 0.001 0.033 T-27 0.033 0.031 0.035 Controls 0.028 0.001 0.038 Controls 0.033 0.025 0.040 T-1 0.031 0.023 0.036 T-1 0.031 0.028 0.035 T-2 0.031 0.024 0.037 T-2 0.031 0.026 0.036 T-3 0.031 0.026 0.035 T-3 0.029 0.025 0.033 T-4 0.030 0.022 0.037 T-4 0.031 0.026 0.036 T-7 0.031 0.024 0.036 T-7 0.032 0.028 0.036 T-8 0.032 0.026 0.038 T-8 0.031 0.026 0.036 Indicators 0.031 0.022 0.038 Indicators 0.031 0.025 0.036 Seetember December Location Average Minima Maxima Location Average Minima Maxima T-9 0.030 0.014 0.049 T-9 0.037 0.035 0.041 T-11 0.035 0.017 0.055 T-11 0.038 0.033 0.043 T-12 0.032 0.016 0.056 T-12 0.031 0.029 0.033 T-27 0.034 0.017 0.052 T-27 0.039 0.034 0.045 Controls 0.033 0.014 0.056 Controls 0.036 0.029 0.045 T-1 0.036 0.018 0.056 T-1 0.037 0.032 0.042 T-2 0.031 0.015 0.047 T-2 0.037 0.032 0.047 T-3 0.035 0.012 0.059 T-3 0.037 0.032 0.040 T-4 0.035 0.014 0.056 T-4 0.035 0.030 0.042 T-7 0.036 0.014 0.058 T-7 0.033 0.024 0.040 T-8 0.034 0.013 0.052 T-8 0.038 0.032 0.045 Indicators 0.035 0.012 0.059 Indicators 0.036 0.024 0.047 Note: Unless otherwise specified, samples collected on the first, second or third day of the month are grouped with data from the previous month.

11-2

r.n 00 Table 12.

Airborne particulates, analyses for strontium-89. strontium-90 and gamma-emitting isotopes.

Location Quarter Lab Code Volume (m 3

)

Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Location Quarter lab Code Volume(m1 Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Collection: Quarter1y Composite Units: pCUmJ 1st Quarter TAP-1586 3397

< 0.0013

< 0.0009 2nd Quarter TAP-3612 3693

< 0.0011

< 0.0009 0.094 :1: 0.018 0.082 :1: 0.014

< 0.027

< 0.023

< 0.0016

< 0.0008

< 0.0024

< 0.0013

< 0.0012

< 0.0006

< 0.0098

< 0.0051

< 0.0010

< 0.0010

< 0.0011

< 0.0007

< 0.0023

< 0.0013

< 0.0060

< 0.0035 1st Quarter 2nd Quarter TAP-1587 TAP* 3613 3397 3759

< 0.0013

< 0.0014

< 0.0009

< 0.0011 0.083 +/- 0.015 0.093 +/- 0.014

< 0.025

< 0.023

< 0.0012

< 0.0008

< 0.0016

< 0.0014

< 0.0009

< 0.0009

< 0.0076

< 0.0071

< 0.0009

< 0.0011

< 0.0006

< 0.0005

< 0.0017

< 0.0013

< 0.0043

< 0.0030 12-1 T-1 3rd Quarter 4th Quarter TAP-5535 TAP-6770 4014 3950

< 0.0006

< 0.0007

< 0.0003

< 0.0005 0.084 +/- 0.016 0.065 +/- 0.012

< 0.018

< 0.020

< 0.0012

< 0.0009

< 0.0017

< 0.0009

< 0.0011

< 0.0010

< 0.0083

< 0.0039

< 0.0009

< 0.0007

< 0.0008

< 0.0008

< 0.0020

< 0.0011

< 0.0038

< 0.0030 T-2 3rd Quarter 4th Quarter TAP-5536 TAP* 6771 3963 4043

< 0.0007

< 0.0005

< 0.0003

< 0.0004 0.096 :1: 0.016 0.073 +/- 0.012

< 0.023

< 0.016

< 0.0013

< 0.0011

< 0.0014

< 0.0010

< 0.0008

< 0.0005

< 0.0062

< 0.0057

< 0.0010

< 0.0007

< 0.0006

< 0.0007

< 0.0020

< 0.0010

< 0.0034

< 0.0024 8S

Table 12.

Airborne particulates, analyses for strontium-89, strontium.90 and gamma--emitting isotopes.

Location Quarter Lab Code Volume (m3>

Sr-89 Sr-90 Be-7 K.40 Nb-95 Zt-95 Ru-103 Ru-106 Cs-134 Cs-137 Ca.141 Ce--144 Location Quarter Lab Code Volume (m3)

Sr-89 Sr-90 Be--7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce--144 Collection: Ouarter1y Composite Units: pCi/m:i 1st Quarter TAP-1588 3432

< 0.0015

< 0.0008 2nd Quarter TAP-3614 3714

< 0.0011

< 0.0009 0.096 +/- 0.020 0.093 +/- 0.016

< 0.021

< 0.023

< 0.0013

< 0.0011

< 0.0013

< 0.0017

< 0.0014

< 0.0010

< 0.0074

< 0.0069

< 0.0010

< 0.0011

< 0.0008

< 0.0006

< 0.0020

< 0.0013

< 0.0039

< 0.0038 1st Quarter 2nd Quarter TAP-1589 TAP-3615 3341 3732

< 0.0010

< 0.0011

< 0.0007

< 0.0008 0.081 +/- 0.016 0.094 :t 0.016

< 0.024

< 0.024

< 0.0010

< 0.0014

< 0.0009

< 0.0019

< 0.0013

< 0.0009

< 0.0072

< 0.0072

< 0.0010

< 0.0010

< 0.0006

< 0.0007

< 0.0024

< 0.0013

< 0.0060

< 0.0037 T-3 3rd Quarter 4th Quarter TAP-5537 TAP-6772 4030 4049

< 0.0005

< 0.0005

< 0.0003

< 0.0004 0.083 :t 0.014 0.073 :t 0.019

< 0.023

< 0.024

< 0.0008

< 0.0027

< 0.0012

< 0.0023

< 0.0006

< 0.0014

< 0.0063

< 0.0105

< 0.0010

< 0.0013

< 0.0009

< 0.0013

< 0.0011

< 0.0021

< 0.0029

< 0.0056 T-4 3rd Quarter 4th Quarter TAP-5538 TAP-6773 3973 3938

< 0.0005

< 0.0004

< 0.0003

< 0.0003 0.096 +/- 0.018 0.070 +/- 0.016

< 0.018

< 0.023

< 0.0009

< 0.0009

< 0.0022

< 0.0010

< 0.0008

< 0.0013

< 0.0047

< 0.0090

< 0.0008

< 0.0012

< 0.0009

< 0.0009

< 0.0011

< 0.0014

< 0.0030

< 0.0049 86

r--

00 Table 12. Airborne particulates, analyses for strontium-69, strontium-SO and gamma-emitting isotopes.

Location Quarter Lab Code Volume (m1 Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Location Quarter lab Code Volume (m3)

Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Collection: Quarterty Composite Units: pCi/m3 1st Quarter TAP-1590 3404

< 0.0010

< 0.0008 0.079 :t 0.016

< 0.023

< 0.0010

< 0.0023

< 0.0009

< 0.0076

< 0.0009

< 0.0006

< 0.0021

< 0.0050 1st Quarter TAP* 1591 3534

< 0.0012

< 0.0009 2nd Quarter TAP-3616 3689

< 0.0009

< 0.0008 0.10 :t 0.016

< 0.023

< 0.0009

< 0.0017

< 0.0009

< 0.0065

< 0.0008

< 0.0007

< 0.0013

< 0.0034 2nd Quarter TAP-3617 3943

< 0.0011

< 0.0009 0.085 i 0.015 0.079 :t 0.015

< 0.020

< 0.023

< 0.0014

< 0.0011

< 0.0012

< 0.0015

< 0.0013

< 0.0008

< 0.0063

< 0.0048

< 0.0008

< 0.0010

< 0.0009

< 0.0006

< 0.0012

< 0.0013

< 0.0048

< 0.0030 12-3 T-7 3rd Quarter 4th Quarter TAP-5539 TAP-6774 4005 4089

< 0.0005

< 0.0005

< 0.0003

< 0.0004 0.090 :t 0.014 0.062 :t 0.025

< 0.022

< 0.037

< 0.0014

< 0.0031

< 0.0019

< 0.0025

< 0.0014

< 0.0024

< 0.0073

< 0.0166

< 0.0008

< 0.0016

< 0.0008

< 0.0021

< 0.0015

< 0.0045

< 0.0064

< 0.0096 T-8 3rd Quarter 4th Quarter TAP* 5540 TAP-6775 4032 4014

< 0.0005

< 0.0004

< 0.0003

< 0.0003 0.092 +/- 0.016 0.060 :t 0.011

< 0.020

< 0.016

< 0.0012

< 0.0008

< 0.0022

< 0.0012

< 0.0013

< 0.0008

< 0.0054

< 0.0073

< 0.0011

< 0.0007

< 0.0006

< 0.0005

< 0.0016

< 0.0007

< 0.0036

< 0.0032 87

00 00 Table 12. Airborne particulates, analyses for strontium-89, stronlium-90 and gamma-emitting isotopes.

Location Quarter Lab Code Volume (m3)

Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Location Quarter Lab Code Volume (m1 Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Collection: Ouarter1y Composite Units: pCi/m3 1st Quarter TAP-1592 3430

< 0.0014

< 0.0010 2nd Quarter TAP-3618 3734

< 0.0011

< 0.0008 0.073 :t 0.013 0.098 +/- 0.017

< 0.017

< 0.024

< 0.0007

< 0.0009

< 0.0018

< 0.0012

< 0.0006

< 0.0010

< 0.0049

< 0.0064

< 0.0006

< 0.0011

< 0.0006

< 0.0005

< 0.0015

< 0.0014

< 0.0041

< 0.0039 1st Quarter 2nd Quarter TAP-1593 TAP-3619 3490 3643

< 0.0011

< 0.0012

< 0.0008

< 0.0010 0.078 +/- 0.011 0.076 +/- 0.016

< 0.021

< 0.024

< 0.0009

< 0.0007

< 0.0011

< 0.0016

< 0.0012

< 0.0006

< 0.0068

< 0.0040

< 0.0008

< 0.0009

< 0.0010

< 0.0008

< 0.0013

< 0.0013

< 0.0041

< 0.0037 12-4 T-9 {C) 3rd Quarter 4th Quarter TAP-5541 TAP-6776 4017 4022

< 0.0006

< 0.0005

< 0.0004

< 0.0003 0.085 +/- 0.017 0.074 :t 0.014

< 0.020

< 0.022

< 0.0008

< 0.0009

< 0.0009

< 0.0010

< 0.0011

< 0.0013

< 0.0071

< 0.0073

< 0.0008

< 0.0010

< 0.0009

< 0.0012

< 0.0019

< 0.0023

< 0.0033

< 0.0054 T-11 (C) 3rd Quarter 4th Quarter TAP-5542 TAP-6777 3980 3966

< 0.0005

< 0.0004

< 0.0003

< 0.0004 0.090 :t 0.015 0.084 +/- 0.014

< 0.018

< 0.026

< 0.0009

< 0.0007

< 0.0016

< 0.0009

< 0.0006

< 0.0011

< 0.0079

< 0.0032

< 0.0010

< 0.0010

< 0.0008

< 0.0004

< 0.0017

< 0.0009

< 0.0058

< 0.0052

0, 00 Table 12.

Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.

Location Quarter Lab Code Volume {m~)

Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Location Quarter Lab Code Volume (m1 Sr-89 Sr-90 Be-7 K-40 Nt:>--95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Collection: Quarter1y Composite Units: pCi/m3 1st Quarter TAP-1594 3380

< 0.0011

< 0.0008 2nd Quarter TAP-3620 3719

< 0.0011

< 0.0009 0.085 :t 0.01 3 0.090 :t 0.016 T-12 (C) 3rd Quarter TAP-5543 3979

< 0.0005

< 0.0002 0.074 +/- 0.010

< 0.017

< 0.023.

< 0.016

< 0.0008

< 0.0011

< 0.0007

< 0.0017

< 0.0016

< 0.0009

< 0.0008

< 0.0007

< 0.0004

< 0.0075

< 0.0086

< 0.0054

< 0.0008

< 0.0009

< 0.0006

< 0.0006

< 0.0006

< 0.0007

< 0.0018

< 0.0014

< 0.0013

< 0.0042

< 0.0038

< 0.0035 T-27 (C) 1st Quarter 2nd Quarter 3rd Quarter TAP-1595 TAP-3621 TAP-5544 3413 3751 3797

< 0.0009

< 0.0010

< 0.0005

< 0.0007

< 0.0008

< 0.00D3 0.082 :t 0.013 0.10 :t 0.016 0.084 :t 0.014

< 0.021

< 0.024

< 0.019

< 0.0014

< 0.0013

< 0.0012

< 0.0019

< 0.0010

< 0.0015

< 0.0012

< 0.0008

< 0.0009

< 0.0043

< 0.0064

< 0.0060

< 0.0008

< 0.0009

< 0.0009

< 0.0007

< 0.0007

< 0.0007

< 0.0020

< 0.0011

< 0.0016

< 0.0042

< 0.0036

< 0.0030 12-5 4th Quarter TAP-6778 3947

< 0.0004

< 0.0003 0.068 :t 0.014

< 0.019

< 0.0007

< 0.0007

< 0.0010

< 0.0045

< 0.0007

< 0.0005

< 0.0014

< 0.0039 4th Quarter TAP-6779 3973

< 0.0004

< 0.0004 0.069 +/- 0.012

< 0.014

< 0.0009

< 0.0011

< 0.0010

< 0.0063

< 0.0006

< 0.0006

< 0.0012

< 0.0027

0 0, Table 13. Area monitors (TLD}, Quarterty.

Units: mR/91 days

.1fil.9!L Indicator T-1 12.8 :t 1.3 T-2 12.4 :t 0.5 T*3 11.0 +/- 0.8 T-4 12.9 t 0.8 T-5 13.3 +/- 0.9 T-6 9.7 :t 0.8 T-7 15.9 :t 0.8 T-8 19.7 +/- 0.6 T-10 13.4 +/- 0.8 T-38 10.7 +/- 0.6 T-39 10.3 :t 1.2 T-40 14.1 +/-0.7 T-41 10.7 +/-0.7 T-42 9.4 :t 0.6 T-43 13.6 t 1.0 T-44 16.9 :t 0.8 T-45 15.9 :t 0.5 T-48 10.3 :t 0.7 T-47 8.9 :t 0.6 T-48 10.2 :t 0.4 T-49 9.6 +/-0.5 T-50 14.7 +/-0.7 T-51 14.9 :t 1.0 T-52 17.8 :t 1.3 T-53 16.3 :t 0.5 T-54 16.3 :t 0.7 T-55 12.9 :t 1.2 T-60 13.1 :t 1.1 T-62 11.8 :t 0.5 T-65 12.5 :t 0.7 T-66 18.6 :t 0.9 T-67 19.0 :t 1.0 T-68 15.9 :t 1.4 T-69 16.8 :t: 0.8 T-71 16.3 :t 0.4 T-73 13.6 :t 0.8 T-74 14.8 :t 0.8 T-75 13.6 :t 0.7 T-76 11.7+/-0.7 T-91 17.2 :t0.7 T-92 12.2 :t 0.4

  • ND = No Data, TLO lost in the field.

9A 2nd Qtr.

3rd Otr.

4thOtr.

9.6 :t 1.2 12.0 :t 1.0 11.4 :t 1.2 11.3 :t 1.1 12.1 :t 0.5 12.6 :t 0.9 9.5 :t: 1.3 11.5 :t 1.0 11.0 :t 1.1 12.1 :t 1.0 13.0 :t: 0.9 13.6 :t 1.1 11.7 :t: 1.3 13.5 :t 0.7 13.0 :t 0.8 9.4 :t: 1.0 10.6 :t 0.7 10.7 :t 0.8 14.5 :t 1.0 15.7 +/-0.7 15.7 :t: 0.9 20.7 :t 1.9 22.8 :t 0.8 22.4 :t 1.8 15.0 :t 1.3 14.0 :t 0.7 15.6 :t 0.8 10.9 :t 1.3 12.0 :t 0.5 11.7 :t 1.5 9.0 :t 1.0 11.8 :t 1.2 9.5 :t: 0.8 12.6 :t 1.6 14.7 +/-0.6 12.7 :t 1.0 8.4 +/- 1.0 11.6 :t 0.7 8.9 :t 1.0 9.6 :t 1.2 10.7 :t 0.5 9.5 +/-0.9 14.1 :t 1.1 15.4 :t 1.5 14.3 :t 1.3 19.5 :t 2.2 18.5 +/- 0.9 18.5 :t 1.5 16.6 :t 1.6 17.3 :t 0.5 16.1 +/-1.6 11.1 :t: 1.2 11.5 :t 0.6 11.0 :t 1.0 11.4 :t 1.5 10.0 :t 0.6 8.7+/-1.1 10.3 t 1.2 11.6 :t 0.4 10.0 :t 1.0 N**

10.2 :t 0.5 9.4 t 1.0 17,2 :t 1.6 14.9 +/-0.5 15.0 :t 1.Q 14.0 :t 1.6 16.7 :t 1.6 13.9 :t 1.3 19.3 :t 1.3 18.2+/-1.7 17.9 +/- 1.0 20.1 +/- 1.2 19.4 :t 0.6 19.4 :t 1.0 16.7 :t 1.8 18.3 :t 0.8 16.0 :t 1.4 13.9 :t 1.8 15.0 :t 1.4 14.1 :1:1.0 11.6 :t 1.6 12.7 +/- 1.5 13.0 :t 1.5 9.0 :t 0.8 11.3 :t 0.7 10.1 t 1.0 11.2 t 0.9 11.2 :t 1.3 12.0 :1: 1.4 17.6 :t 1.2 18.8 +/-0.7 18.1 :t 1.3 17.9 +/- 1.0 19.1 :t:0.9 18.6 :t 1.1 14.4 :t 0.8 15.9 t 1.2 14.6 :t 0.9 16.2 :t 0.8 16.1 +/-0.7 16.9 +/- 1.0 16.6 +/- 1.0 15.4 :t 0.5 18.4 :t 1.0 12.4 :t: 1.3 12.8 +/- 0.9 13.2 :t 1.3 13.5 :1: 1.5 14.3 +/- 0.9 14.3 :t 1.6 12.0 :t 1.0 12.6 :1: 0.7 13.0 :t: 1.0 11.2 :t 1.2 10.8 :t 0.7 11.8 :t 1.1 16.8 :t: 1.5 18.8 :t 1.1 16.8 t 1.5 11.5 t 0.8 12.7 :t 0.5 11.8 t 0.9 13-1

O'I Table 13. Area monitors (TLD), Ouarterty.

Units: mR/91 days 1fil..9!!:.

Indicator T-93 15.1 :t 0.9 T-94 15.9 +/- 1.1 T-112 13.3 :t 0.6 T-121 18.0 :t 1.2 T-122 14.3+/-1.1 T-123 17.5 :1:0.5 T-125 16.6 :t 0.7 T-126 13.8 :t 0.5 T-127 17.4 :t 0.6 T-128 17.9 :t 1.1 T-142 10.4 :t 0.5 T-150 13.7 :t 0.8 T-151 18.9 :t 1.6 T-153 18.1 :i:0.7 T-154 20.6 t 0.4 T-201 13.0 :t 0.6 T-202 14.4 :t 1.0 T-203 14.9 :t0.6 T-204 13.3 :t 0.7 T-205 12.0 :t 1.2 T-206 9.8 :t 0.6 T-207 9.3 :t 0.9 T-208 10.8 :t 1.0 T-211 10.1 :t 0.6 T-212 8.6 :t 0.5 T-213 15.1 :t 0.9 T-214 16.3 :t 0.6 T-215 16.1 :t 0.6 T-216 15.4 :t 0.9 T-217 19.8.t 0.9 T-218 19.2 :t 0.6 T-219 14.7 :i:0.9 T-220 17.2 :t 0.8 T-222 14.2+/-1.1 T-223 14.2 :t 0.8 T-224 11.7+/-0.6 Mean :t: s.d.

14.2 :t 3.0 ND = No Data; TLC lost in the field.

2nd Qtr.

3rd Qtr.

4th Otr.

13.3 +/- 1.1 15.1 +/- 0.8 12.7 :t 1.1 16.1 :t 1.6 17.2 i:0.8 17.5 :I: 1.7 15.0 :t 1.2 14.0 :t 0.6 14.9 :t 1.2 19.6 :t 1.4 18.7 +/- 1.2 19.1 :t 1.2 14.4 :t 1.5 14.9 :t 1.0 14.0 :t 1.0 17.2 :t 0.9 18.1 :t 0.9 16.8 +/- 1.0 16.9 :t 0.9 18.9 :t 1.2 15.1 :t 1.0 13.7+/-1.4 14.7 :t 1.1 13.5 :t 1.4 17.5 :t 1.6 18.4 t 0.9 18.1 :t 1.4 17.4+/-1.1 18.6 :t 1.3 17.4:tl.1 10.5 :t 1.0 11.0 +/-0.7 11.2 :t 1.2 13.3 :t 1.2 14.5 :t 1.1 13.4 :t 1.4 18.1 :t 1.6 20.6 :t 1.7 18.8 :t 1.3 20.6 :t 0.9 22.2 +/-0.9 17.5 :t 1.1 18.2 :t 1.2 22.1 :t 0.8 19.2 :t 1.4 13.1 :t 0.5 13.5 :t 0.8 13.0 :t 0.4 12.3 :t 0.8 13.7 :t 1.0 12.3 +/- 0.7 14.3 :t 1.0 16.0 :t 1.5 14.8 :t 1.4 14.1 +/-1.6 14.1 :t 1.0 13.7 +/-0.9 9.6 :t 0.7 12.0 :t 0.8 10.1 :1: 0.8 10.5 :t 0.6 10.6 :t 0.9 10.6 :t 0.7 10.1 :t 0.7 10.2 :t 0.9 10.0 :t 0.6 9.6 :i:0.6 11.5 :t 1.2 10.1 :t 0.5 8.5 :t 0.9 10.3 :t 0.8 8.5 :i:0.9 8.9 :t 0.9 9.1 :i:0.7 9.1 :t 0.9 16.0 :t 1.2 15.2 :t 0.5 16.1 :t 0.9 15.2.t 0.9 17.0 :t 0.5 15.1 :t 0.9 16.2 +/- 1.5 17.1 :i:0.7 18.5 :t 1.2 13.3 :t 1.0 16.5 :t 1.1

12. 7 :t 1.1 19.2 :t 1.7 21.4 :t 1.1 16.5 t 1.5 20.5 :t 1.6 20.6.t 0.7 19.2 :t 1.3 13.5 :t 1.2 15.3 :t 1.0 12.8 :t 1.2 18.6 :t 1.2 18.2 :t 0.9 17.9 :t 1.1 NO*

14.0 :t 1.0 13.1 :t 1.1 13.7 :t 1.3 14.4 :t: 0.8 14.3 :t 1.1 12.1 :t: 0.9 11.6 :t 0.7 11.5 :t 0.8 14.0 :t 3.5 14.9 :t 3.4 14.1 :t 3.2 13-2

N 0,

Table 13. Area monitors (TLD), Quarterly.

Units: mR/91 days llL.9!L 2nd Qlr.

Control T-9 13.2 :t 0.8 13.9 :t 1.2 T-11 12.3 :t 0.8 13.3+/-1.1 T-12 15.9 :t 0.7 16.0 +/- 1.2 T-24 16.7 +/- 1.2 15.8 :t 1.0 T-27 17.7 :t: 1.2 18.5 :t 1.4 Mean :t s.d.

15.2 +/- 2.3 15.5 :t 2.0 T-95 15.7 :t 0.9 16.0 :t 1.0 T-100 15.0 +/- 1.2 15.1 +/- 1.2 T-111 15.9 +/- 1.5 16.6 +/- 1.1 T-124 19.1 +/- 1.0 18.7 :t 0.9 T-155 16.4 :t 0.6 14.6 :t 1.7 T-221 14.7 :t0.6 17.0 :t 1.3 Mean+/-s.d.

16.1 :t 1.6 16.3 :t 1.5

~

T-80 11.3 :t: 1.1 9.9 :1:0.9 T-81 18.1 t 0.7 17.0 t 0.9 T-82 11.4+/-0.7 10.2 t 1.2 T-83 11.1 :t 0. 7 9.7 +/- 1.5 T-84 11.5 :t 0.8 10.3 +/- 0.8 T-85 12.7 :t 1.0 12.5 :t 1.2 T-86 17.5 :t 0.7 16.2 +/- 0.9 T-88 15.6 :t 1.1 14.2 :I: 0.9 T-89 15.2 :t: 1.0 14.5 :t: 1.0 T-113 13.5 :t 0.6 14.2.:t 1.0 T-114 19.1 :t:0.7 17.6 :t 1.1 T-115 19.3 :t 0.7 17.8 :t 1.2 T-116 17.5 :t 0.8 17.3 :t 1.0 T-117 13.0 :t:0.7 14.8 :t 1.8 T-118 15.3 :t 0.6 14:8 :t: 0.7 T-119 13.4 :t 0.6 14.2 :t 1.2 T-120 11.9 :t 0.7 10.8 :t 1.1 T-200 11.6 :t 0.7 12.4 :t 0.7 Mean :t s.d.

14.4 :t: 2.9 13.8 :t: 2.8 Shield T-87 5.9 :t:0.6 6.1 +/- 1.1 13-3 9:>

3rd atr.

4th Otr.

14.2 :t 0.8 13.1 :t 0.9 13.4 :t: 0.8 12.5 :t 1.0 16.7 +/- 0.6 16.0 +/- 1.6 18.4 :t 1.0 16.8 :t 0.8 18.4 :t 1.3 18.0 :t 1.4 16.2 :t: 2.3 15.3 :t 2.4 16.9 +/- 1.2 13.6 +/- 1.0 15.9 :t 1.2 14.8 +/- 1.1 15.9 :t 1.2 16.8 :t 1.2 20.1 :t 1.4 18.3 :t 1.2 17.1 :t 0.9 15.5 :t 1.7 17.1 :t: 0.8 17.0 :t 1.1 17.2 :t 1.5 16.0 :t 1.7 11.5 t 1.1 10.7+/-1.0 17.6 :t 0.9 17.6 :t 1.0 11.8 :1:0.6 11.0 :t 1.3 11.2 :t 0.8 10.4 :t 1.5 12.4 +/- 0.8 10.8 :t 0.9 12.7 :t 0.9 12.7 :t 1.2 18.3 :t 0.9 16.0 :t 1.0 16.1 :t 1.0 14.0 :t 0.9 14.6 :t 0.6 14.3 :t 1.0 14.4 :t 0.6 14.0 :1: 1.2 20.9.:t 0.8 17.9 :t 1.0 20.1 :t:0.8 17.9 t 1.3 19.5 :t 0.9 17.9 :t 1.4 13.7 :t0.7 16.3 :t 1.1 16.6 :t 0.9 14.4 :t 0.9 13.5 :I: 0.7 13.4 :t 1.1 13.5 t 0.6 9.4 :t: 1.1 12.9 :t: 0.8 12.2 :t 0.8 15.1 :t: 3.1 14.0 :t 2.9 6.8 :t0.9 5.8 :t 1.1

Table 14. Area monitors (TLD), Annual.

Indicator T-1 T-2 T-3 T-4 T-5 T-6 T-7 T-8 T-10 T-38 T-39 T-40 T-41 T-42 T-43 T-44 T-45 T-46 T-47 T-48 T-49 T-50 T-51 T-52 T-53 T-54 T-55 T-60 T-62 T-65 T-66 T-67 T-68 T-69 T-71 T-73 T-74 T-75 T-76 T-91 T-92 Units: mR/365 days 8 ND= No Data, TLD lost in the field.

2017 44.0 ::t 1.8 48.5 :1: 1.3 44.7 +/-2.3 47.6 :t 2.2 57.1 :1:2.0 43.0 ::t 1.3 62.7 :t::4.7 79.2 :1: 1.5 58.4 :t:3.2 46.0 :t 1.6 44.7 :1: 1.5 55.6 :t 3.3 45.5 :t 1.0 44.4 :I: 2.8 55.6 +/-2.6 75.5 :t 3.5 68.6 +/-2.6 49.3 :t 1.9 40.9 t 1.0 46.0 :t 2.3 N0° 67.2 :t 3.4 67.8 :t 1.8 77.3 :t 3.2 69.3 :t 1.5 76.5 :I: 2.6 55.3 :t 4.9 42.1 :t 2.8 41.2 +/-3.5 45.1 :t 3.3 61.9 ::t:2.7 67.3 :1: 2.4 52.6 ::t 2.5 60.7 :t: 2.7 59.1 :t 1.9 45.2 ::t 2.0 56.6 +/- 2.6 47.7 :t: 3.5 44.0 +/- 2.3 69.2 ::t 2.0 51.1 :t 2.7 14-1 93

Table 14. Area monitors (TLD), Annual.

Indicator T-93 T-94 T-112 T-121 T-122 T-123 T-125 T-126 T-127 T-128 T-142 T-150 T-151 T-153 T-154 T-201 T-202 T-203 T-204 T-205 T-206 T-207 T-208 T-211 T-212 T-213 T-214 T-215 T-216 T-217 T-216 T-219 T-220 T-222 T-223 T-224 Mean+/- s.d.

Units* mR/:\\RS rt;:iyi.

a ND= No Data, TLD lost in the field.

2017 56.8 :t 2.9 66.6 +/-3.0 53.2 +/- 3.0 74.2 :t 5.2 58.7 +/-3.0 68.2 +/- 3.3 62.9 :t 2.3 56.2 :t 2.7 74.6 +/-3.9 70.7 +/-6.2 43.6 :t 2.0 S0.4 +/-2.6 77.0 :t 2.7 77.6 +/-4.7 74.8 :t 2.3 50.9 :t 2.4 61.3 +/- 2.2 66.4 :1: 3.4 51.1 +/- 2.7 46.7 :t 2.3 42.2 +/- 2.1 40.0 :1: 2.4 41.6 +/-2.2 38.2 +/- 2.8 37.4 +/- 2.6 62.5 :t 3.5 73.1 +/- 2.1 71.0 +/- 1.6 61.6 :t 3.1 72.2 +/- 2.3 76.9 :t 2.1 58.7 +/-2.3 71.1 +/- 2.6 ND 8

58.3 :t 1.6 48.0 :1: 2.8 57.5 :t 12.1 14-2 94

r.n 0,

Table 14. Area monitors (TLD), Annual.

T-9 T-11 T-12 T-24 T-27 Units: mru:365 days Mean+/- s.d.

T-95 T-100 T-111 T-124 T-155 T-221 Mean :t s.d.

T-80 T-81 T-82 T-83 T-84 T-85 T-86 T-88 T-69 T-113 T-114 T-115 T-116 T-117 T-118 T-119 T-120 T-200 Mean :t s.d.

T-87 2017 52.3 +/- 1.9 49.8 :t 1.2 70.1 ::t:2.0 70.0 +/- 3.3 75.7 :t 2.3 63.6 :t 11.7 61.5 +/- 4.3 62.1 :t 2.2 65.2 +/-4.0 78.2 +/- 3.9 57.8 ::t: 3.2 66.1 :t 2.6 65.2 +/- 7.0 37.7 +/- 1.8 73.9 ::t: 2.3 41.4::t:1.8 40.8 +/- 2.4 43.2 :t 1.9 46.1 ::t: 2.7 67.6 +/- 2.5 63.0 :t 2.8 60.4 +/- 4.9 60.7 +/- 2.7 66.4 :t 2.2 73.5 ::t: 3.4 64.3 +/-2.1 51.0 +/- 2.4 56.9 +/- 2.1 51.1 :t 3.8 40.7 :t 1.8 45.2 +/- 2.6 54.7 :t 12.0 25.3 +/- 1.8 14-3 9S

1..0 0,

96 Table 15. Milk, analyses for strontium-89. strontium-90, iodine-131, gamma emitting isotopes.

calcium and stable potassium.

Monthly collections, location T-24 Units: pCi/L Date Collected 01-31-17 02-28-17 03-29-17 05-03-17 Lab Code TMI* 356 TMI-795 TMI-1216 TMI-1943 1-131

< 0.2

< 0.3

< 0.1

< 0.5 Sr-89

< 0.5

< 0.6

< 0.5

< 0.5 Sr-90

< 0.5

< 0.5

< 0.6

< 0.6 K-40 1440 :t 97 1401 :t 97 1341 :t 106 1383 :1: 117 Cs-134

< 2.7

< 3.6

< 3.5

< 4.3 Cs-137

< 3.3

< 3.1

< 3.3

< 4.2 Ba-La-140

< 1.5

< 3.0

< 3.5

< 3.0 Ca (g/L) 0.99 1.00 1.12 0.91 Sr-90/g Ca

< 0.51

< 0.50

< 0.54

< 0.66 K (g/L) 1.76 :t 0.12 1.71 +/- 0.12 1.64 :t 0.13 1.69 :I: 0.14 Cs-137/g K

< 1.88

< 1.81

< 2.01

< 2.49 Date Collected 05-30-17 07-06-17 08-02-17 08-30-17 Lab Code TMI-2510 TMI-3245 TMI-3906 TMI-4403 J-131

< 0.4

< 0.3

< 0.3

< 0.2 Sr-89

< 0.6

< 0.5

< 0.6

< 0.5 Sr-90

< 0.6 0.9 :t 0.3

< 0.5

< 0.5 K-40 1325 :t 138 1387 :t 96 1433 :t 136 1441 :t 113 Cs-134

< 4.4

< 2.9

< 4.0

< 4.2 Cs-137

< 5.5

< 3.3

< 6.0

< 4.3 Ba-La-140

< 2.9

< 3.8

< 2.2

< 2.7 Ca (g/L) 1.00 0.98 0.95 0.93 Sr-90/g Ca

< 0.60 0.92

< 0.53

< 0.54 K (g/L) 1.62 :t 0.17 1.69 :t 0.12 1.75 :t 0.17 1.76::1:0.14 Cs-137/g K

< 3.40

< 1.95

< 3.43

< 2.44 Date Collected 10-04-17 11-01-17 11-29-17 01-03-18 Lab Code TMI-5108 TMJ-5756 TMI-6224 TMI-6603 1-131

< 0.3

< 0.3

< 0.4

< 0.4 Sr-89

< 0.6

< 0.6

< 0.6

< 0.6 Sr-90

< 0.6

< 0.5 0.8 :t 0.3

< 0.5 K-40 1369 :t 119 1362 :t 119 1414 +/- 102 1308.:t 103 Cs-134

< 3.8

< 4.0

< 3.2

< 3.3 Cs-137

< 3.8

< 2.9

< 3.0

< 3.6 Ba-La-140

< 2.1

< 6.7

< 2.6

< 3.0 Ca (g/L) 1.17 0.91 1.07 0.90 Sr-90/g Ca

< 0.51

< 0.55 0.75

< 0.56 K (gll) 1.67 :I: 0.15 1.66+/-0.15 1.72 :t 0.12 1.60 :t 0.13 Cs-137fg K

< 2.28

< 1.75

< 1.74

< 2.25 15-1

r--

0, Table 16. Ground water samples, analyses for gross beta, tritium, strontium-89, gamma-emitting isotopes.

Collection: Quarterly Units: pCi/l Period 1st Qtr.

2nd Otr.

3rd Qtr.

Location T-27A (C)

Lab Code TWW-1259 TWW-2574 TWW-3929 Date Collected 03-29-17 05-17-17 07-19-17 Gross beta

< 1.7

< 3.7 1.3 +/- 0.7 H-3

< 330

< 330

< 330 Sr-89

< 0.5

< 0.7

< 1.5 Sr-90

< 0.5

< 0.4

< 0.7 Mn-54

< 3.0

< 2.0

< 1.3 Fe-59

< 4.8

< 5.0

< 3.1 Co-58

< 2.5

< 1.8

< 0.8 Co-60

< 1.7

< 2.1

< 0.9 Zn-65

< 4.2

< 2.4

< 2.1 Zr-Nb-95

< 2.2

< 3.8

< 2.4 Cs-134

< 3.3

< 2.8

< 1.1 Cs-137

< 3.3

< 2.5

< 0.8 Ba-La-140

< 3.4

< 4.8

< 4.6 Location T-225 (I)

Lab Code TWW-1261 TWW-2575 TWW-3931 Date Collected 03-29-17 05-17-17 07-19-17 Gross beta 2.8 :t: 0.8 1.6 :t: 0.6 1.8 :t: 0.6 H-3

< 330

< 330

< 330 Sr-89

< 0.6

< 0.7

< 1.0 Sr-90

< 0.5

<0.4

< 0.5 Mn-54

< 1.8

< 2.3

< 1.1 Fe-59

< 3.8

< 5.2

< 1.5 Co-58

< 2.1

< 2.4

< 1.0 Co-60

< 1.7

< 1.1

< 0.9 Zn-65

< 3.0

< 4.5

< 2.0 Zr-Nb-95

< 2.4

< 3.0

< 2.4 Cs-134

< 2.5

< 2.2

< 1.1 Cs-137

< 2.9

< 1.9

< 1.2 Ba-La-140

< 2.9

< 6.4

< 5.7 16-1 97 strontium-90 and 4th Qtr.

TWW-5818 Req.LLD 10-17-17

< 3.5 4.0

< 330 330

< 0.7

<0.4

< 1.2 15

< 7.1 30

< 2.0 15

< 0.7 15

< 3.9 30

< 2.7 15

< 2.3 15

< 2.1 18

< 4.3 15 TWW-5820 Req. LLD 10-17-17 5.7 :t: 0.9 4.0

< 330 330

< 0.7

< 0.4

< 1.0 15

< 5.2 30

< 2.1 15

< 1.7 15

< 3.0 30

< 3.3 15

< 2.3 15

< 2.6 18

< 7.2 15

00 0,

Table 16. Ground water samples, analyses for gross beta, tritium, strontium-89, gamma-emitting isotopes.

Collection: Quarterly Units: pCi/L Period 1st Qtr.

2nd Qtr.

3rd Qtr.

Location T-226 (I)

Lab Code ND' ND 0

ND 0

Date Collected Gross beta H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co--60 Zn--65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Location T-141 (QC)

Lab Code TWW-1260 TWW-2576 TWW-3930 Date Collected 03-29-17 05--17-17 07-19-17 Gross beta 3.1 :t 0.8 2.2 :t 0.6 2.2 :t 0.6 H-3

< 330

< 330

< 330 Sr-89

< 0.6

< 0.8

< 0.9 Sr-90

< 0.5

< 0.6

< 0.5 Mn-54

< 2.3

< 1.8

< 1.3 Fe--59

< 4.1

< 4.4

< 2.4 Co-56

< 2.5

< 1.6

< 1.1 Co--60

< 2.1

< 1.8

< 1.0 Zn-65

< 4.3

< 3.0

< 2.3 Zr-Nb-95

< 3.6

< 2.9

< 2.3 Cs-134

< 3.1

< 2.7

< 1.1 Cs-137

< 1.5

< 1.9

< 1.2 Ba-La-140

< 2.1

< 6.3

< 6.7 a "ND"= No data: see Table 2.0, Listing of Missed Samples.

16-2 98 strontium-90 and 4th Otr.

ND 0

Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 TWW-5819 Req.LLD 10-17-17 3.3 +/- 0.8 4.0

< 330 330

< 0.8

< 0.4

< 1.5 15

< 3.3 30

< 2.5 15

< 1.2 15

< 4.0 30

< 3.6 15

< 2.1 15

< 2.1 18

< 8.1 15

0, 0,

~~

Table 19. Green leafy vegetables, analyses for strontium-89, stron1ium-90, iodine-131 and other gamma-emitting isotopes.

Collection: Monthly, in season Units: pCi/g wet Location T-19\\Q 19C 19K Lab Code TVE-3908 TVE-3909 TVE-4428 TVE-4429 Date Collected 08-01-17 06-01-17 08-29-17 08-29-17 Sample Type Cabbage Kale Cabbage Kale Sr-89

< 0.003

< 0.008

< 0.002

< 0.005 Sr-90

< 0.001

< 0.005

< 0.001

< 0.003 1-131

< 0.014

< 0.019

< 0.013

< 0.023 K-40 2.20 :t: 0.17 4.58 :.t: 0.28 1.98+/-0.19 3.63 +/- 0.30 Nb-95 *

< 0.006

< 0.008

< 0.009

< 0.011 Zr-95

< 0.009

< 0.014

< 0.010

< 0.017 Cs-134

< 0.005

< 0.008

< 0.007

< 0.010 Cs-137

< 0.005

< 0.006

< 0.008

< 0.006 Ce-141

< 0.010

< 0.012

< 0.015

< 0.012 Ce-144

< 0.037

< 0.038

< 0.038

< 0.062 Location T-19 (I)

Lab Code TVE-4966 TVE-4967 TVE-5769 TVE-5770 Date Collected 09-27-17 09-27-17 11-01-17 11-01-17 Sample Type Kale Cabbage Cabbage Kale Sr-89

< 0.015

< 0.008

< 0.005

< 0.016 Sr-90

< 0.010

< 0.005

< 0.003

< 0.011 1-131

< 0.022

< 0.022

< 0.014

< 0.013 K-40 4.19 :1: 0.29 1.91 :t 0.19 1.94 :t: 0.21 4.55 :t 0.35 Nb-95

< 0.014

< 0.009

< 0.009

< 0.007 Zr-95

< 0.015

< 0.011

< 0.012

< 0.015 Cs-134

< 0.008

< 0.006

< 0.010

< 0.009 Cs-137

< 0.009

< 0.007

< 0.007

< 0.013 Ce-141

< 0.021

< 0.016

< 0.016

< 0.017 Ce-144

< 0.043

< 0.048

< 0.087

< 0.094 Location T-30 T-37 (q Lab Code TVE-4675 TVE-4969 TVE-3910 TVE-4430 Date Collected 09-13-17 09-27-17 08-01-17 08-29-17 Sample Type Kale Kale Cabbage Cabbage Sr-89

< 0.007

< 0.016

< 0.003

< 0.001 Sr-90

< 0.005

< 0.011

< 0.001

< 0.001 1-131

< 0.013

< 0.029

< 0.019

< 0.014 K-40 4.32 +/- 0.28 5.32 +/- 0.35 2.27 :t 0.18 1.67 :t: 0.18 Nb-95

< 0.006

< 0.012

< 0.005

< 0.009 Zr-95

< 0.013

< 0.019

< 0.009

< 0.008 Cs-134

< 0.009

< 0.011

< 0.005

< 0.007 Cs-137

< 0.009

< 0.008

< 0.005

< 0.006 Ce-141

< 0.010

< 0.021

< 0.009

< 0.016 Ce-144

< 0.054

< 0.063

< 0.033

< 0.039 19-1

0 0

~

Table 19. Green leafy vegetables, analyses for strontium-89, strontium-90, iodine-131 and other gamma-emitting isotopes.

Collection: Monthly, in season Units: pCi/g wet Location T-37 (C)

T-227 (I)

Lab Code TVE-4968 TVE-4431 TVE-4970 TVE-5771 Date Collected 09-27-17 08-29-17 09-27-17 11-01-17 Sample Type Cabbage Cabbage Cabbage Cabbage Sr-89

< 0.005

< 0.002

< 0.006

< 0.009 Sr-90

< 0.003

< 0.001

< 0.005

< 0.006 1-131

< 0.015

< 0.016

< 0.019

< 0.010 K-40 2.08.t 0.18 2.15 +/- 0.19 2.27 +/- 0.21 2.77 +/- 0.24 Nb-95

< 0.007

< 0.008

< 0.009

< 0.007 Zr-95

< 0.007

< 0.010

< 0.008

< 0.009 Cs-134

< 0.006

< 0.006

< 0.007

< 0.007 Cs-137

< 0.007

< 0.007

< 0.006

< 0.006 Ce-141

< 0.012

< 0.016

< 0.012

< 0.011 Ce-144

< 0.046

< 0.055

< 0.051

< 0.066 19-2 1 (,) (,)

S 1 (,') 1 Table 20. Fruit, analyses for strontium-89, strontium-90, iodine-131 and other gamma-emitting isotopes.

Collection: Monthly, in season Units: pCi/g wet Location T-8 (I)

T-25 (I)

Lab Code TVE-4971 TVE-4972 Date Collected 09-27-17 09-27-17 Sample Type Apples Apples Sr-89

< 0.003

< 0.003 Sr-90

< 0.002

< 0.002 1-131

< 0.019

< 0.022 K-40 0.93 +/- 0.12 1.03 +/- 0.13 Nb-95

< 0.004

< 0.004 Zr-95

< 0.012

< 0.010 Cs-134

< 0.005

< 0.005 Cs-137

< 0.006

< 0.004 Ce-141

< 0.011

< 0.011 Ce-144

< 0.042

< 0.038 Location T-209 (C)

Lab Code TVE-4973 Date Collected 09-27-17 Sample Type Apples Sr-89

< 0.004 Sr-90

< 0.003 1-131

< 0.014 K-40 1.17 +/- 0.13 Nb-95

< 0.006 Zr-95

< 0.010 Cs-134

< 0.005 Cs-137

< 0.003 Ce-141

< 0.009 Ce-144

< 0.044 20-1

N 0

~

1 0?

Table 22. Soil samples, analyses for gamma-emitting isotopes.

Collection: Annual Units: pCi/g dry Location T-1 T-2 T-3 T-4 Lab Code TSO-2564 TSO-2565 TSO-2566 TSO-2567 Date Collected 06-16-17 05-16-17 05-16-17 05-16-17 Be-7 0.64 :t 0.19 1.05 +/- 0.29

< 0.28 1.26 +/- 0.53 K-40 9.11 +/- 0.64 3.81 +/- 0.47 6.03 +/- 0.50 17.13 +/- 0.99 Mn-54

< 0.019

< 0.017

< 0.019

< 0.029 Nb-95

< 0.030

< 0.036

< 0.046

< 0.052 Zr-95

< 0.040

< 0.033

< 0.033

< 0.093 Ru-103

< 0.014

< 0.026

< 0.028

< 0.032 Ru-106

< 0.188

< 0.201

< 0.129

< 0.174 Cs-134

< 0.017

< 0.017

< 0.016

< 0.021 Cs-137 0.067 +/- 0.022 0.054 :t 0.021

< 0.023 0.066 :t 0.030 Ce-141

< 0.040

< 0.064

< 0.076

< 0.123 Ce-144

< 0.138

< 0.103

< 0.121

< 0.199 Location T-7 T-8 Lab Code TSO-2568 TSO-2569 Date Collected 05-16-17 05-16-17 Be-7 1.88 :t 0.35 0.79 +/- 0.34 K-40 11.61 t 0.68 18.28 +/- 0.78 Mn-54

< 0.014

< 0.030 Nb-95

< 0.038

< 0.046 Zr-95

< 0.042

< 0.064 Ru-103

< 0.022

< 0.039 Ru-106

< 0.116

< 0.137 Cs-134

< 0.017

< 0.018 Cs-137 0.036 +/- 0.020 0.052 :t 0.016 Ce-141

< 0.050

< 0.070 Ce-144

< 0.109

< 0.104 Location T-9 T-11 T-12 T-27 Lab Code TSO-2570 TSO-2571 TSO-2572 TSO-2573 Date Collected 05-16-17 05-16-17 05-16-17 05-16-17 Be-7 0.78 :t 0.36

< 0.32 0.36 +/- 0.21

< 0.34 K-40 16.60 +/- 0.88 11.01 +/- 0.67 14.65 +/- 0.79 20.33 +/- 0.85 Mn-54

< 0.031

< 0.023

< 0.020

< 0.028 Nb-95

< 0.059

< 0.040

< 0.055

< 0.057 Zr-95

< 0.078

< 0.057

< 0.046

< 0.063 Ru-103

< 0.042

< 0.034

< 0.023

< 0.046 Ru-106

< 0.227

< 0.129

< 0.176

< 0.157 Cs-134

< 0.027

< 0.019

< 0.016

< 0.017 Cs-137 0.18 t 0.055

< 0.029 0.040 +/- 0.021 0.13 +/- 0.026 Ce-141

< 0.117

< 0.073

< 0.076

< 0.077 Ce-144

< 0.136

< 0.160

< 0.115

< 0.172 22-1

Table 23. Treated surface water samples, analyses for gross beta.

Collection: Monthly composites of weekly grab samples Units: pCi/L T-11 (q Lab Code Date Collected Gross Beta lab Code TSWT-388 01-31-17 1.6 :t 0.6 TSWT-389 TSWT-805 02-28-17 1.5 +/- 0.6 TSWT-806 TSWT-1233 03-28-17 2.3 :t 0.7 TSWT-1234 TSWT-1975 05-02-17 1.1 :I: 0.5 TSWT-1976 TSWT-2622 05-30-17 1.0 :t 0.5 TSWT-2623 TSWT-3258 07-05-17 1.0 ::t 0.5 TSWT-3259 TSWT-3918 08-01-17 1.2 :I: 0.5 TSWT-3919 TSWT-4404 08-29-17 1.1 :t: 0.5 TSWT-4405 TSWT-5151 10-03-17 2.4 :t: 1.1 TSWT-5152 TSWT-5806 10-31-17 1.1 :t 0.5 TSWT-5807 TSWT-6212 11-28-17 1.2 :t 0.5 TSWT-6213 TSWT-6635 12-26-17 1.4 :t 0.5 TSWT-6636 T-22 TSWT-390 01-31-17 1.2 :t 0.6 TSWT-391 TSWT-807 02-28-17 1.3 :t: 0.5 TSWT-808 TSWT-1235 03-28-17 2.2 :t 0.7 TSWT-1236 TSWT-1977 05-02-17 1.2:t 0.5 TSWT-1978 TSWT-2624 05-30-17 1.3 :t 0.6 TSWT-2625 TSWT-3260 07-0$-17

< 0.8 TSWT-3261 TSWT-3920 08-01-17 1.8 :t: 0.7 TSWT-3921 TSWT-4406 08-29-17 1.7 :t 0.6 TSWT-4407 TSWT-5153 10-03-17 1.1 +/- 0.5 TSWT-5154 TSWT-5808 10-31-17 1.1 :t: 0.5 TSWT-5809 TSWT-6214 11-28-17 1.1 :t: 0.5 TSWT-6215 TSWT-6638 12-26-17 1.3 :t: 0.6 TSWT-6639 23-1 1 f) '.1 T-12 (C)

Date Collected Gross Beta 01-31-17 1.5 :t 0.6 02-28-17 1.1 :t 0.5 03-28-17 2.4 :t 0.8 05-02-17 1.4 :I: 0.5 05-30-17 1.3 :t 0.6 07-05-17 1.2 ::t 0.5 08-01-17

< 0.9 08-29-17

< 0.9 10-03-17 1.8 :t 0.6 10-31-17

< 0.9 11-28-17 1.0 :t 0.5 12-26-17 0.9 :I: 0.5 T-143 (QC) 01-31-17 1.4 :t: 0.6 02-28-17

< 0.9 03-28-17 2.5 :t 0.8 05-02-17

< 0.9 05-30-17 1.1 :t: 0.5 07-05-17

< 0.9 08-01-17

< 1.8 08-29-17 1.9 +/- 0.6 10-03-17 1.3 +/- 0.6 10-31-17 1.5 :i: 0.6 11-28-17 1.2 :t 0.6 12-26-17 1.1 :t: 0.5

Table 24.

Location Period Lab Code H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn~S Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Location Period Lab Code H-3 Sr-89 Sr-90 Mn-54 Fe-59 C~58 Co-60 Zn~S Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Treated surtace water samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly composites of weekly grab &ample:.

Units: pCi/L T-11 {C!

1st Otr.

2nd Otr.

3rd Otr.

TSWT-1355 TSWT-3364 TSWT-5234

< 330

< 330

< 330

< 0.5

< 0.6

< 0.6

< 0.5

< 0.5

< 0.5

< 1.8

< 2.1

< 3.3

< 3.7

< 4.5

< 7.8

< 1.4

< 2.3

< 2.9

< 2.0

< 1.6

< 3.9

< 2.4

< 5.3

< 3.6

< 3.1

< 2.5

< 2.8

< 1.8

< 2.3

< 4.1

< 2.0

< 2.0

< 3.9

< 4.7

< 2.2

< 5.3 T-12 {C~

1st Otr.

2nd Otr.

3rd Qtr.

TSWT-1357 TSWT-3365 TSWT-5235

< 330

< 330

< 330

< 0.7

< 0.8

< 0.7

< 0.7

< 0.6

< 0.6

< 1.7

< 2.7

< 3.4

< 4.2

< 3.9

< 9.0

< 1.8

< 2.2

< 4.0

< 1.1

< 1.8

< 3.8

< 2.9

< 4.2

< 3.3

< 2.5

< 3.0

< 2.5

< 1.6

< 2.5

< 4.2

< 1.3

< 3.0

< 4.2

< 6.5

< 2.6

< 3.3 24-1 4th Qtr.

TSWT-6725

< 330

< 0.7

< 0.5

< 2.2

< 5.5

< 1.8

< 2.4

< 3.4

< 3.8

< 3.7

< 1.6

< 5.5 4th Qtr.

TSWT-6726

< 330

< 0.6

< 0.5

< 3.3

< 5.2

< 2.4

< 2.2

< 3.7

< 3.9

< 2.9

< 3.2

< 6.9 1 8 4 Reg.LLD 330 15 30 15 15 30 15 10 18 15 Reg.LLD 330 15 30 15 15 30 15 10 18 15

Table 24.

Location Period Lab Code H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Treated surface water samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes.

Collet;tiun: Quarterly composites of weekly grab samples.

Units: pCill T-22 1st Qtr.

2nd Otr.

3rd Qtr.

TSWT-1358 TSWT-3366 TSWT-5236

< 330

< 330

< 330

< 0.8

< 0.6

< 0.5

< 1.0

< 0.5

< 0.5

< 1.3

< 1.7

< 3.1

< 3.8

< 4.1

< 9.3

< 1.3

< 1.5

< 2.7

< 1.5

< 1.6

< 2.8

< 3.1

< 2.5

< 8.3

< 2.3

< 1.9

< 4.2

< 1.6

< 2.8

< 3.9

< 1.8

< 2.4

< 4.6

< 6.2

< 2.9

< 4.4 24-2 4th Otr.

TSWT-6727

< 330

< 0.6

< 0.5

< 2.9

< 5.9

< 1.8

< 2.9

< 3.4

< 5.0

< 2.4

< 1.8

< 5.5 105 Reg.LLD 330 15 30 15 15 30 15 10 18 15

1..0 0

~

1 0 f; Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-3 Collection: Monthly composites of weekly grab samples Units: pCi/L Lab Code TSWU-393 TSWU-809 TSWU-1237 TSWU* 1979 Date Collected 01-31-17 02-28-17 03-28-17 05-02-17 Req.LLD Gross beta 3.6 :1: 0.8 2.3 :1: 0.6 3.4 :1: 0.8 2.4 +/- 0.7 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 3.2

< 3.4

< 3.3

< 2.6 15 Fe-59

< 3.9

< 5.1

< 5.4

< 7.2 30 Co-58

< 2.4

< 3.3

< 4.7

< 2.2 15 Co-60

< 1.6

< 3.4

< 2.5

< 2.4 15 Zn-65

< 3.1

< 7.4

< 7.1

< 4.2 30 Zr-Nb-95

< 3.5

< 5.2

< 4.0

< 4.5 15 Cs-134

< 3.3

< 4.0

< 4.0

< 3.2 10 Cs-137

< 4.5

< 2.5

< 4.5

< 2.7 18 Ba-la-140

< 4.8

< 3.0

< 3.5

< 6.5 15 lab Code TSWU-2627 TSWU-3262 TSWU-3922 TSWU-4408 Date Collected 0S-30-17 07-05-17 08-01-17 08-29-17 Req. LLD Gross beta 2.3 +/- 0.6 1.3 :I: 0.6 1.7 ::t 0.6 1.9 :t 0.6 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 3.2

< 1.9

< 3.3

< 3.8 15 Fe-59

< 4.8

< 3.9

< 10.5

< 10.2 30 Co-58

< 1.6

< 1.6

< 2.3

< 4.8 15 Co-60

< 2.2

< 1.9

< 2.8

< 5.3 15 Zn-65

< 3.3

< 5.2

< 3.7

< 7.1 30 Zr-Nb-95

< 3.6

< 3.3

< 4.3

< 5.5 15 Cs-134

< 3.3

< 2.5

< 3.9

< 4.8 10 Cs-137

< 3.4

< 2.1

< 2.6

< 2.9 18 Ba-La-140

< 2.4

< 2.4

< 7.4

< 5.6 15 Lab Code TSWU-5155 TSWU-5810 TSWU-6216 TSWU-6640 Date Collected 10-03-17 10-31-17 11-28-17 12-26-17 Req.LLD Gross beta 1.0 ::t 0.5 3.4 ::t 0.7 2.7 ::t 1.1 1.9 :I: 0.6 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 3.1

< 1.9

< 2.3

< 1.8 15 Fe-59

< 5.1

< 3.8

< 2.7

< 7.1 30 Co-58

< 3.5

< 2.3

< 1.5

< 2.7 15 Co-60

< 2.8

< 1.9

< 1.9

< 2.6 15 Zn-65

< 3.4

< 3,9

< 6.2

< 3.7 30 Zr-Nb-95

< 3.2

< 2.8

< 3.0

< 3.4 15 Cs-134

< 3.6

< 2.8

< 2.8

< 3.3 10 Cs-137

< 3.2

< 3.7

< 2.7

< 3.5 18 Ba-La-140

< 1.6

< 4.0

< 1.5

< 3.7 15 25-1

r--

0

~

1 fl 7 Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-11 (C)

Collection: Monthly composites of weekly grab samples Unili;. µCi/L Lab Code TSWU-395 TSWU-811 TSWU-1239 TSWU-1981 Date Collected 01-31-17 02-28-17 03-28-17 05--02-17 Req. LLD Gross beta

< 1.7 2.1 +/- 0.6

< 2.3

< 1.7 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 2.5

< 2.0

< 2.8

< 2.1 15 Fe-59

< 5.1

< 1.8

< 5.1

< 3.9 30 Co-58

< 2.4

< 1.9

< 2.6

< 2.3 15 Co-60

< 2.5

< 2.6

< 2.3

< 2.0 15 Zn-65

< 4.3

< 5.2

< 4.2

< 1.3 30 Zr-Nb-95

< 3.4

< 2.7

< 3.8

< 2.4 15 Cs-134

< 3.4

< 2.8

< 3.4

< 2.3 10 Cs-137

< 3.3

< 2.4

< 2.6

< 2.6 18 Ba-La-140

< 3.5

< 1.2

< 2.2

< 6.9 15 Lab Code TSWU-2629 TSWU-3264 TSWU-3924 TSWU-4410 Date Collecte<I 0S-30-17 07-05-17 08-01-17 08-29-17 Req. LLD Gross beta

< 1.7

< 1.6 1.0 :t 0.5

< 1.7 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 1.6

< 3.1

< 2.5

< 2.9 15 Fe-59

< 4.1

< 5.2

< 6.1

< 5.2 30 Co-58

< 1.5

< 3.0

< 2.3

< 4.1 15 Co-60

< 1.5

< 3.2

< 1.3

< 4.9 15 Zn-65

< 4.7

< 5.4

< 3.4

< 11.2 30 Zr-Nb-95

< 1.7

< 3.8

< 3.8

< 5.2 15 Cs-134

< 2.7

< 3.5

< 3.0

< 5.6 10 Cs-137

< 3.3

< 2.3

< 2.5

< 5.0 18 Ba-La-140

< 1.3

< 4.2

< 4.4

< 5.9 15 Lab Code TSWU-5157 TSWU-5812 TSWU-6218 TSWU-6642 Date Collected 10--03-17 10-31-17 11-28-17 12-26-17 Req.LLO Gross beta

< 1.8 2.4 +/- 1.1

< 1.7 1.7 :t 0.6 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 2.2

< 1.7

< 2.6

< 3.0 15 Fe-59

< 3.0

< 5.3

< 3.9

< 3.3 30 Co-58

< 3.1

< 2.5

< 1.9

< 2.8 15 Co-60

< 1.4

< 1.5

< 2.3

< 1.5 15 Zn-65

< 2.8

< 2.4

< 3.7

< 4.4 30 Zr-Nb-95

< 3.0

< 3.3

< 1.3

< 3.8 15 Cs-134

< 3.0

< 2.8

< 2.9

< 2.9 10 Cs-137

< 1.6

< 3.4

< 2.9

< 2.7 18 Ba-La-140

< 2.3

< 4.1

< 1.5

< 2.6 15 25-2

00 0

~

1 (-') ~

Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-12 (C)

Collectlon: Monthly composites of weekly grab samples Unit:;: pCi/L Lab Code TSWU-396 TSWU-812 TSWU* 1240 TSWU* 1982 Date Collected 01-31-17 02-28-17 03-28-17 05-02-17 Req. LLD Gross beta 1.9 +/- 0.6 1.7 +/- 0.6 1.8 +/- 0.8 1.8 :t 0.6 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 4.0

< 2.9

< 2.5

< 3.2 15 Fe-59

< 4.9

< 5.7

< 5.3

< 8.8 30 Co-58

< 2.7

< 3.0

< 2.6

< 2.1 15 Co-60

< 3.1

< 1.3

< 2.6

< 3.2 15 Zn-65

< 6.4

< 4.8

< 4.4

< 5.4 30 Zr-Nb-95

< 3.5

< 2.3

< 2.1

< 3.6 15 Cs-134

< 4.3

< 4.0

< 1.9

< 4.0 10 Cs-137

< 3.3

< 2.2

< 2.7

< 3.0 18 Ba-La-140

< 5.3

< 3.5

< 2.6

< 5.7 15 Lab Code TSWU-2630 TSWU-3266 TSWU-3925 TSWU-4411 Date Collected 05-30-17 07--05-17 08-01-17 08-29-17 Req. LLD Gross beta 2.2 :t 0.6 1.3 +/- 0.6

< 0.8 1.0 :t 0.5 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 3.3

< 6.1

< 3.1

< 3.4 15 Fe-59

< 5.9

< 9.3

< 5.4

< 7.5 30 Co-58

< 1.9

< 4.1

< 2.3

< 2.1 15 Co-60

< 2.0

< 6.2

< 1.5

< 3.0 15 Zn-65

< 3.8

< 16.8

< 2.7

< 7.4 30 Zr-Nb-95

< 2.3

< 8.7

< 4.5

< 3.5 15 Cs-134

< 3.2

< 6.3

< 3.2

< 3.6 10 Cs-137

< 3.1

< 4.2

< 2.2

< 3.5 18 Ba-La-140

< 2.5

< 10.7

< 5.7

< 5.1 15 Lab Code TSWU-5158 TSWU-5813 TSWU-6219 TSWU-6643 Date Collected 10-03-17 10-31-17 11-28-17 12-26-17 Req. LLD Gross beta 1.5 +/- 0.6 1.6 :t 0.6 1.7 :t 0.6 1.2 +/- 0.5 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 3.8

< 3.8

< 3.3

< 2.2 15 Fe-59

< 6.8

< 2.7

< 5.3

< 8.7 30 Co-58

< 3.6

< 2.4

< 1.9

< 1.9 15 Co-60

< 3.1

< 1.9

< 2.3

< 2.2 15 Zn-65

< 5.5

< 1.9

< 3.6

< 5.1 30 Zr-Nb-95

< 5.7

< 2.9

< 1.6

< 4.0 15 Cs-134

< 4.4

< 3.0

< 3.6

< 3.4 10 Cs-137

< 3.5

< 3.1

< 3.5

< 1.8 18 Ba-La-140

< 4.0

< 4.0

< 3.5

< 5.1 15 25-3

Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-22 Collection: Monthly composites of weekly grab samples Unils: pCi/L Lab Code TSWU-398 TSWU* 814 TSWU-1242 TSWU-1984 Date Collected 01-31-17 02-28-17 03-28-17 05-02-17 Req.LLD Gross beta 2.1 :t 0.6 3.1 :t 0.7 2.5 +/- 0.7 1.7 t 0.6 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 3.5

< 3.0

< 3.9

< 2.5 15 Fe-59

< 3.8

< 4.1

< 6.7

< 3.9 30 Co-58

< 2.8

< 2.0

< 4.2

< 2.7 15 Co-oO

< 2.0

< 2.6

< 4.0

< 2.3 15 Zn-65

< 4.9

< 3.9

< 5.5

< 2.9 30 Zr-Nb-95

< 1.7

< 2.7

< 2.3

< 1.9 15 Ci;.134

< 3.6

< 3.5

< 4.4

< 2.8 10 Cs-137

< 3.1

< 2.5

< 4.5

< 1.8 18 Ba-La-140

< 2.9

< 2.5

< 2.8

< 3.2 15 Lab Code TSWU-2632 TSWU-3268 TSWU-3927 TSWU-4413 Date Collected 05-30-17 07-05-17 08--01-17 08-29-17 Req.LLD Gross beta 1.3 :t:: 0.6 1.5 :t 0.6 1.8 :t 0.6

< 1.0 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 1.9

< 3.7

< 3.1

< 3.4 15 Fe-59

< 5.7

< 9.1

< 6.6

< 5.6 30 Co-58

< 2.3

< 2.0

< 2.2

< 3.5 15 Co-60

< 2.2

< 3.2

< 1.9

< 2.6 15 Zn-65

< 3.6

< 5.0

< 3.1

< 11.1 30 Zr-Nb-95

< 1.7

< 3.6

< 5.3

< 5.0 15 Cs-134

< 2.7

< 3.5

< 3.5

< 5.1 10 Cs-137

< 2.9

< 4.0

< 2.8

< 4.1 18 Ba-La-140

< 1.3

< 1.5

< 6.3

< 6.3 15 Lab Code TSWU-5160 TSWU-5815 TSWU-6222 TSWU-6645 Date Collected 10-03-17 10-31-17 11-28-17 12-26-17 Req. LLD Gross beta 1.2 :t 0.6 2.8 +/- 0.7 1.7 :t 0.6 1.5 :t 0.6 4.0 I

H-3

< 330

< 330 791 i: 109

< 330 330 Mn-54

< 2.9

< 1.5

< 3.0

< 2.7 15 Fe-59

< 5.2

< 4.4

< 4.4

< 6.5 30 Co-58

< 1.9

< 1.3

< 2.4

< 2.8 15 Co-60

< 2.0

< 1.0

< 2.6

< 2.2 15 Zn-65

< 3.3

< 2.4

< 5.3

< 2.5 30 Zr-Nb-95

< 3.3

< 3.3

< 2.4

< 3.8 15 Cs-134

< 3.4

< 2.8

< 2.5

< 2.9 10 Cs-137

< 3.1

< 3.1

< 3.8

< 3.4 18 Ba-La-140

< 2.0

< 3.7

< 1.9

< 5.3 15

'Tritium reanalyzed with a result of 792+/-122 pCi/L.

25-4

0 --

1 1 (,}

Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-145 {QC)

Collection: Monthty composites of weekly grab samples Units: pCIIL Lab Code TSWU* 399 TSWU-815 TSWU* 1244 TSWU-1985 Date Collected 01-31-17 02-28-17 03-28-17 0S--02-17 Req. LLD Gross beta

< 1.9 2.1 t 1.1

< 2.2

< 1.7 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 5.0

< 3.9

< 1.4

< 2.5 15 Fe-59

< 8.7

< 6.9

< 4.5

< 5.9 30 Co-58

< 4.1

< 3.6

< 1.7

< 2.3 15 Co-60

< 6.0

< 2.0

< 1.9

< 2.0 15 Zn-65

< 12.4

< 5.2

< 3.2

< 4.2 30 Zr-Nb-95

< 6.0

< 2.6

< 2.7

< 2.6 15 Cs-134

< 5.9

< 3.9

< 3.0

< 2.5 10 Cs-137

< 5.5

< 2.6

< 2.7

< 3.7 18 Ba-La-140

< 6.8

< 2.9

< 1.8

< 5.2 15 Lab Code TSWU-2633 TSWU-3269 TSWU-3928 TSWU-4414 Date Collected 05-30-17 07--05-17 08-01-17 08-29-17 Req.LLO Gross beta

< 1.7

< 1.9 2.8 t 1.4

< 1.7 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 1.9

< 2.2

< 2.8

< 3.3 15 Fe-59

< 4.6

< 4.1

< 3.7

< 5.1 30 Co-58

< 2.9

< 1.6

< 2.5

< 2.8 15 Co-60

< 3.2

< 2.3

< 1.7

< 3.6 15 Zn-65

< 1.9

< 4.2

< 3.9

< 4.8 30 Zr-Nb-95

< 3.3

< 3.0

< 3.5

< 4.0 15 Cs-134

< 2.9

< 2.5

< 3.2

< 4.3 10 Cs-137

< 2.3

< 2.8

< 2.7

< 4.7 18 Ba-La-140

< 2.7

< 3.2

< 4.2

< 3.2 15 Lab Code TSWU-5161 TSWU-5816 TSWU-6223 TSWU-6646 Da1e Collected 10-03-17 10-31-17 11-28-17 12-26-17 Req. LLD Gross beta 2.2 t 1.0 2.0 +/- 1.0 1.4 t 0.6 1.0 +/- 0.5 4.0 H-3

< 330

< 330 889 +/- 113

< 330 330 Mn-54

< 3.0

< 2.4

< 2.9

< 1.9 15 Fe-59

< 5.1

< 3.8

< 3.6

< 4.5 30 Co-58

< 2.9

< 3.2

< 2.6

< 3.8 15 Co-60

< 3.3

< 2.1

< 2.3

< 2.6 15 Zn-65

< 4.8

< 4.6

< 4.5

< 4.2 30 Zr-Nb-95

< 3.7

< 2.5

< 2.4

< 4.1 15 Cs-134

< 3.8

< 3.6

< 3.3

< 3.9 10 Cs-137

< 3.7

< 3.7

< 3.2

< 3.4 18 Ba-La-140

< 2.4

< 3.8

< 2.7

< 7.0 15

  • Tritium reanalyzed with a result of 780+/-111 pCi/L.

25-5

l 1 l Table 26. Untreated surface water samples, analyses for strontium-89 and strontium-90.

Collection: Quarter1y composites of weekly grab samples Units: pCi/L Location T-3 Period 1st Otr.

2nd Qtr.

3rd Qtr.

4th Ctr.

Lab Code TSWU-1403 TSWU-3552 TSWU-5237 TSWU* 6728 Sr-89

< 0.5

< 0.7

< 0.6

< 0.7 Sr-90

< 0.5

< 0.6

< 0.5

< 0.5 Location T-11 (C)

Period 1st Otr.

2nd Otr.

3rd Otr.

4th Ctr.

Lab Code TSWU-1404 TSWU-3553 TSWU-5238 TSWU-6729 Sr-89

<0.6

< 0.6

< 0.5

< 0.7 Sr-90

< 0.6

< 0.5

< 0.4

< 0.5 Location T-12 (C)

Period 1st Otr.

2nd Ctr.

3rd Qtr.

4th Qtr.

Lab Code TSWU-1406 TSWU-3554 TSWU-5239 TSWU-6730 Sr-89

< 0.6

< 0.7

< 0.5

< 0.6 Sr-90

<0.6

< 0.5

< 0.5

< 0.5 Location T-22 Period 1st Otr.

2nd Otr.

3rd Qtr.

4th Qtr.

Lab Code TSWU-1407 TSWU-3555 TSWU-5240 TSWU-6731 Sr-89

< 0.7

< 0.7

< 0.6

< 0.6 Sr-90

< 0.7

< 0.6

< 0.5

< 0.5 26-1

Table 27. Fish samples. analyses for gross beta and gamma-emitting isotopes.

Collection: Annually Units: pCi/g wet Location Lab Code TF-4506 Date Collected 07-26-17 Sample Type Walleye Gross Beta 3.40 +/- 0.07 K-40 2.95 +/- 0.44 Mn-54

< 0.012 Fe-59

< 0.064 Co-58

< 0.022 Co-60

< 0.019 Zn-65

< 0.024 Cs-134

< 0.013 Cs-137

< 0.013 Location Lab Code TF-4508 Date Collected 07-26-17 Sample Type Walleye Gross Beta 3.49 +/- 0.07 K-40 2.48 +/- 0.31 Mn-54

< 0.010 Fe-59

< 0.024 Co-58

< 0.016 Co-60

< 0.006 Zn-65

< 0.037 Cs-134

< 0.015 Cs-137

< 0.011 T-33 (Lake Erie. 1.5 mi. NE of Station)

TF-4507 08-30-17 White Bass/

White Perch 2.84 +/- 0.06 2.29 +/- 0.35

< 0.011

< 0.021

< 0.011

< 0.013

< 0.025

< 0.014

< 0.011 T-35 TF-4509 07-26-17 White Bass/

White Perch 1.18+/-0.03 1.00 +/- 0.25

< 0.009

< 0.045

< 0.014

< 0.008

< 0.018

< 0.016

<0.013 27-1 1 1 2

11 3 Table 28. Shoreline sediment samples, analyses for gamma-emitting isotopes.

Collection: Semiannually Units: pCi/g dry Location T-3 T--4 T--4P T-278 T-132 Lab Code TS$- 2558 TSS-2559 TSS-2560 TSS-2561 TSS-2562 Date Collected 05-24-17 05-24-17 05-24-17 05-24-17 05-24-17 K--40 9.75 :1: 0.53 18.70:t 1.00 23.00 +/- 1.21 8.77 +/- 0.52 8.64 :1: 0.49 Mn-54

< 0.015

< 0.038

< 0.032

< 0.017

< 0.010 Co-58

< 0.017

< 0.039

< 0.054

< 0.020

< 0.014 Co-60

< 0.018

< 0.022

< 0.031

< 0.014

< 0.009 Cs-134

< 0.011

< 0.028

< 0.028

< 0.010

< 0.009 Cs-137

< 0.013

< 0.034 0.15 :t 0.066

< 0.012

< 0.009 Lab Code TSS-6240 TSS-6241 TSS-6242 TSS-6244 TSS-6245 Date Collected 11-29-17 11-29-17 11-29-17 11-28-17 11-28-17 K--40 10.08 :1: 0.53 11.62 +/- 0.65 21.61 :1: 1.00 12.64 :I:. 0.63 10.06 :1: 0.56 Mn-54

< 0.018

< 0.022

< 0.032

< 0.017

< 0.018 Co-58

< 0.013

< 0.020

< 0.032

< 0.021

< 0.020 Co-60

< 0.012

< 0.016

< 0.016

< 0.012

< 0.012 Cs-134

< 0.014

< 0.013

< 0.026

< 0.012

< 0.013 Cs-137

< 0.014

< 0.020 0.085 +/- 0.026

< 0.015

< 0.016 28-1

  • A*m Environmental, Inc.

M.

Midwest Laboratory 100L..mn1rRr>>d*NotrN1trioA.L~n,o phOI-. (l,f7J IJH4700

  • IV (1.-r} &U-4617 NOTE:

APPENDIX A INTER LABO RA TORY COMPARISON PROGRAM RESULTS ANO INTRALABORATORY COMPARISON PROGRAM RESULTS Appendix A is updated four Umes a year. The complete appendix is Included in March, June, September and December monthly progress reports only.

January. 2017 through December, 2017 1 1 4

Appendix A lnterlaboratory/ lntralaboratory Comparison Program Results Environmental, Inc.* Midwest laboratory has participated in interlaboratory comparison (crosscheck) programs since the formulation of it's quality control program in December 1971. These programs are operated by agencies which supply environmental type samples containing concentrations of radionuclides known to the issuing agency but not to participant laboratories. The purpose of such a program is to provide an independent check on a laboratory's analytical procedures and to alert ii of any possible problems.

Participant laboratories measure the concentration of specified radionuclides and report them to the issuing agency. Several months later, the agency reports the known values to the participant laboratories and specifies control limits. Results consistently higher or lower than the known values or outside the control limits indicate a need to check the instruments or procedures used.

Results in Table A-1 were obtained through participation in the RAD PT Study Proficiency Testing Program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada.

Table A-2 lists results for thermoluminescent dosimeters (TLDs), via irradiation and evaluation by the University of Wisconsin-Madison Radiation Calibration Laboratory at the University of Wisconsin Medical Radiation Research Center.

Table A-3 lists results of the analyses on in-house *spiked" samples fur the past twelve months. All samples are prepared using NIST traceable sources. Data for previous years available upon request.

Table A-4 lists results of the analyses on in-house "blank" samples for the past twelve months. Data for previous years available upon request.

Table A-5 lists analytical results from the in-house "duplicate* program for the past twelve months. Acceptance is based on the difference of the results being less than the sum of the errors.

Complete analytical data for duplicate analyses is available upon request.

The results in Table A-6 were obtained through participation in the Mixed Analyte Perfonnance Evaluation Program.

Results in Table A-7 were obtained through participation in the MRAD PT Study Proficiency Testing Program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the Environmental Measurement Laboratory Quality Assessment Program (EML).

Attachment A lists the laboratory precision at the 1 sigma level for various analyses. The acceptance criteria in Table A-3 is set at :t 2 sigma.

Out-of-limit results are explained directly below the result.

A1 1 1 S

1..0 --

Attachment A ACCEPTANCE CRITERIA FOR "SPIKED" SAMPLES LABORATORY PRECISION: ONE STANDARD DEVIATION VALUES FOR VARIOUS ANALYSES 11 Analysis Gamma Emitters Strontium-89b Strontium-90b Potassium-40 Gross alpha Gross beta Tritium Radium-226,*228 Plutonium lodine-131, lodine--129b Uranium-238, Nickel-63b Technetium.9gb Other Analyses b Level 5 to 100 pCi/liter or kg

> 100 pCi/liter or kg 5 to 50 pCi/liter or kg

> 50 pCi/liter or kg 2 to 30 pCi/liter or kg

> 30 pCi/liter or kg 2: 0.1 g/liter or kg s 20 pCi/liter

> 20 pCi/liter s 100 pCi/liter

> 100 pCi/liter s 4,000 pCi/liter

> 4,000 pCi/liler 2: 0.1 pCi/liter 2: 0.1 pCi/liter, gram, or sample s 55 pCi/liter

> 55 pCi/liter s 35 pCi/liter

> 35 pCi/liter 50 to 100 pCi/liter

> 100 pCi/liter

  • From EPA publication. "Environmental Radioactivity LebOtatory lntercomparison Studies Program", FiSGSI Year. 1981-1982, EPA-600J4-8U)04.

b Laboratory limit.

A2 One standard deviation for single determination 5.0 pCi/liter 10% of known value 5.0 pCi/liter 10% of known value 5.0 pCi/liter 10% of known value 10% of known value 5.0 pCi/liter 25% of known value 5.0 pCi/liter 10% of known value

t 10 =

169.85 x (known)0*0933 10% of known value 15% of known value 10% of known value 6 pCilliter 10% of known value 6 pCi/liter 15% of known value 1 O pCi/liter 10% of known value 20% of known value 1 1 h

TABLE A-1. lntertaboratory Comparison Crosscheck program, Envlronmental Resource Associates (ERA)*.

RAD study Concentration ieci/q Lab Code Date Anatysls Laboratory ERA Con!IOI Result Result Limits Acceetance ERW-95 1/9/2017 Sr-89 51.9 +/-4.6 55.5 44.3

  • 63.2 Pass ERW-95 1/9/2017 Sr-90 43.6 :t 2.4 43.1 31.8 - 49.5 Pass ERW-97 1/9/2017 Ba-133 78.2 t 4.1 85.6 72.0 - 94.2 Pass ERW-97 1/9/2017 Cs-134 53.9 t 3.8 52.6 42.4 - 57.9 Pass ERW-97 1/9/2017 Cs-137 122 :t 6 112 101-126 Pass ERW-97 1/9/2017 Co-60 117 :t 4 113 102-126 Pass ERW-97 1/9/2017 Zn-65 208 :t 13 189 170
  • 222 Pass ERW-99 1/9/2017 Gr. Alpha 48.9 t 2.4 52.3 27.3
  • 65.5 Pass ERW-99 1/9/2017 Gr. Beta 37.1 :t 1.3 41.6 27.7 - 49.0 Pass ERW-101 1/9/2017 1-131 22.3 t 0.6 24.3 20.2
  • 28.8 Pass ERW-103 1/9/2017 Ra-226 11.3 :t 0.4 12.7 9.5 - 14.7 Pass ERW-103 1/9/2017 Ra-228 6.10 :t 0.90 6.20 3.8 - 8.1 Pass ERW-103 1/9/2017 Uranium 11.8 :t 0.8 12.6 9.9
  • 14.4 Pass ERW-106 1/9/2017 H-3 12,600 :t 300 12,500 10,900 - 13,800 Pass ERW-3344 7/10/2017 Sr-89 29.0 t 10.0 26.4 18.4
  • 32.9 Pass ERW-3344 7/10/2017 Sr-90 33.8 t 3.3 36.0 26.4 - 41.5 Pass ERW-3346 7/10/2017 Ba-133 66.4 +/-4.1 66.3 55.2
  • 72.9 Pass ERW-3346 7/10/2017 Cs-134 27.0 :t:4.3 24.4 18.7 -27.2 Pass ERW-3346 7/10/2017 Cs-137 57.4 +/-4.5 51.6 46.4
  • 59.6 Pass ERW-3346 7/10/2017 Co-60 92.6 :t 4.4 88.6 79.7 - 99.8 Pass ERW-3346 7/10/2017 Zn-65 32.4 :t 6.0 32.7 27.3
  • 41.6 Pass ERW-3348 7/1012017 Gr. Alpha 23.7 :t 1.9 25.7 13.0
  • 34.1 Pass ERW-3348 7/10/2017 Gr. Beta 54.6 :t 1.6 63.0 43.5 - 69.6 Pass ERW-3350 7/10/2017 1-131 25.4 :t 1.3 25.5 21.2
  • 30.1 Pass ERW-3352 7/10/2017 Ra-226 1.38 t 0.15 1.29 1.07 - 1.95 Pass ERW-3352 7/10/2017 Ra-228 6.70 :t 0.93 5.66 3.45
  • 7.47 Pass ERW-3352 7/10/2017 Uranium 58.4 :t 0.9 66.7 54.3 - 73.9 Pass ERW-3354 7110/2017 H-3 5,254 +/- 224 5,060 4,340 - 5,570 Pass
  • Results obtained by Environmental, Inc., Midwest Laboratol)' as a participant In the crosscheck program for proficiency testing in drinking water conductoo by Environmental Resources A.$sociates (ERA).

A1-1 1 1 7

00 --

1 1 8 TABLE A-2. Toennoluminescent Dosimetry, (TLC, Caso~: Dy Cards).

  • mrnm Lab Code lnadiation Delivered Reported "

Perfonnance c Date Description Dose Dose OuoUent (P)

Eovjronmental Inc Group 1 2017-1 10/16/2017 Spike 1 59.0 49.3

--0.16 2017-1 10/16/2017 Spike 2 59.0 53.2

-0.10 2017-1 10/16/2017 Spike 3 59.0 52.7

-0.11 2017-1 10/16/2017 Spike 4 59.0 53.4

-0.09 2017-1 10/16/2017 Spike 5 59.0 51.8

-0.12 2017-1 10/16/2017 Spike 6 59.0 54.0

-0.08 2017-1 10/16/2017 Spike 7 59.0 52.0

-0.12 2017-1 10/16/2017 Spike 8 59.0 52.6

-0.11 2017-1 10/16/2017 Spike 9 59.0 54.6

-0.07 2017-1 10/16/2017 Spike 10 59.0 50.4

-0.15 2017-1 10/16/2017 Spike 11 59.0 53.9

-0.09 2017-1 10/16/2017 Spike 12 59.0 55.7

-0.06 2017-1 10/16/2017 Spike 13 59.0 50.2

-0.15 2017-1 10(16/2017 Spike 14 59.0 52.4

-0.11 2017-1 10/1612017 Spike 15 59.0

. 54.3

-0.08 2017-1 10/16/2017 Spike 16 59.0 53.2

-0.10 2017-1 10/16/2017 Spike 17 59.0 50.1

-0.15 2017-1 10/16/2017 Spike 18 59.0 52.3

-0.11 2017-1 10/16/2017 Spike 19 59.0 50.3

-0.15 2017-1 10/16/2017 Spike 20 59.0 50.7

-0.14 2017-1 10/16/2017 Spike 21 59.0 53.1

-0.10 2017-1 10/16/2017 Spike 22 59.0 51.5

-0.13 2017-1 10/16/2017 Spike 23 59.0 54.4

-0.06 2017-1 10/16/2017 Spike 24 59.0 53.3

-0.10 2017-1 10/16/2017 Spike 25 59.0 53.7

-0.09 2017-1 10/1612017 Spike 26 59.0 51.6

-0.13 2017-1 10/1612017 Spike 27 59.0 51.5

-0.13 2017-1 10/16/2017 Spike 28 59.0 51.6

-0.13 2017-1 10/16/2017 Spike 29 59.0 49.9

-0.15 2017-1 10/16/2017 Spike 30 59.0 55.3

-0.06 Mean (Spike 1-30) 52.4

-0.11 Passd Standard Devlatlon (Spike 1-30) 1.7 0.03 Pass0 a TI.D's ware Irradiated by the University of Wisoonsi~dison Radiation Cslibretion Laboratory following ANSI N1J.37 protocol from a known air karma rate. TlD's were read end the resulls were submitted by Environmental Inc. to lhe University of Wisconsin-Madison Radiation Calibration Laboratory for comparison to the delivered dose.

b Reported dose was converted from e.xposull't (R) to Air Kerma (cGy) using e conve111ion or 0.878. Conversion from air kerme to ambient dose equivalent for Cs-137 al the rarerence dose point H'(10)K. = 1.20. mrem/cGy = 1000.

c Perf0rn1anoe Quotient (P) is calculated as ((reported dose* coovantially true value) + conventially true valua) v.ilere lhe conventlally true value Is the delivered dose.

d Acceptance Is achieved v.ilen neither the absolute value of mean of lhe P values, nor the standard deviation of the P values exceed 0.15.

Al-1

0, --

, 1 ~

TABLE A-2. Thermoluminescent Dosimetry, (TLD. CaSO,: Dy Cards).

  • mrem Lab Code Irradiation Delivered Reported i, Performance "

Date Descrtetion Dose Dose Quotient lP~

Environmental. Inc.

Group 2 2017-2 10116/2017 Spike 31 186.0 184.7

-0.11 2017-2 10/16/2017 Spike 32 186.0 172.0

-0.08 2017-2 10/16/2017 Spike 33 186.0 167.3

-0.10 2017-2 10/16/2017 Spike 34 186.0 160.6

-0.14 2017-2 10/16/2017 Spike 35 188.0 171.7

-0.08 2017-2 10/16/2017 Spike 36 186.0 177.0

-0.05 2017-2 10/16/2017 Spike 37 186.0 176.7

-0.05 2017-2 10/16/2017 Spike 38 186.0 165.5

-0.11 2017-2 10/16/2017 Spike 39 186.0 174.6

-0.06 2017-2 10/16/2017 Spike 40 186.0 172.7

-0.07 2017-2 1011612017 Spike 41 186.0 167.8

-0.10 2017-2 10/16/2017 Spike 42 186.0 161.0

-0.13 2017-2 10/16/2017 Spike 43 186.0 166.3

-0.11 2017-2 10116/2017 Spike44 186.0 172.4

-0.07 2017-2 1011612017 Spike 45 186.0 173.0

-0.07 2017-2 10/16/2017 Spike 46 186.0 169.5

-0.09 2017-2 10/16/2017 Spike 47 186.0 169.0

-0.09 2017-2 10/1612017 Spike 48 186.0 166.9

-0.10 2017-2 10/16/2017 Splke49 186.0 165.9

-0.11 2017-2 10/16/2017 Spike 50 186.0 166.7

-0.10 2017-2 10/16/2017 Spike 51 186.0 161.1

-0.13 2017-2 10/16/2017 Spike 52 186.0 173.4

-0.07 2017-2 10/16/2017 Spike 53 186.0 173.1

-0.07 2017-2 10/16/2017 Spike 54 186.0 160.0

-0.14 2017-2 10116/2017 Spike 55 186.0 166.1

-0.11 2017-2 10/16/2017 Spike 56 186.0 164.5

-0.12 2017-2 10/16/2017

$pike 57 186.0 163.8

-0.12 2017-2 10/16/2017 Spike 58 166.0 159.9

-0.14 2017-2 10/16/2017 Spike 59 186.0 165.6

-0.11 2017-2 10/16/2017 Spike 60 186.0 165.0

-0.11 Mean (Spike 31-60) 167.8

-0.10 Passd Standard Deviation (Spike 31-60) 5.0 0.03 Passa a TL D's v.,ira irradiated by the Univenllty of Wisconsin-Madison Radiation Calibration Laboratory following ANSI N 13.37 prot000I from a known air kerma rate. TLD's were read and the results were submitted by Environmental Inc. to the University of Wisconsi...-Madison Radiation CaUbretlon Laboratory for 00mparison to the delivered dose.

b Reported dose was converted from exposure (R) to Air Karma (cGy) using a converalon of 0.876. Conversion from air kerma to amblent dose equivalent for Cs-137 et the reference dose point H'(10)K." 1.20. mrernlcGy = 1000.

c Perf01mance Quotient {P) Is calculated as ((reported dose* conventially true value) + convenlie!lytrue vallle) where the 00nventia11y tn.ie value is the delivered dose.

d Acceptance is achieved when neither the absolute value of mean of the P values, nor the standard deviation of the P values exceed 0. 15.

A:J.-'I.

1 2 0 TABLE A-3. In-House "Spikedw Samples r.nnr:Antmlinn

  • Lab Code b Date Analysis Laboratory results Known Control 2s, n=1 c Activity Limits 0 Acceptance W-010417 4/29/2016 Cs-134 38.2 :t 8.1 36.2 29.0 - 43.4 Pass W-010417 4/29/2016 Cs-137 78.0 :t 8.8 71.9 57.5 - 86.3 Pass SPW-306 1/4/2017 Ra-226 18.1 :t 0.4 16.7 13.4
  • 20.1 Pass SPW-32 1/6/2017 H-3 17,649 :t 393 17,243 10,346
  • 24. 140 Pass SPW-46 1/9/2017 Gr. Alpha 20.0 :t 0.4 20.1 16.1
  • 24.1 Pass SPW-46 1/912017 Gr. Beta 29.0 :t 0.3 26.9 23.1 - 34.6 Pass SPW-92 1/11/2017 H-3 18,095 :t 397 17,243 10,346
  • 24,140 Pass SPW-142 1/1212017 Sr-90 39.4 :t: 2.3 36.6 29.3
  • 43.9 Pass SPW-155 1/19/2017 H-3 17,974 :t 400 17,243 10,346 - 24,140 Pass SPW-186 1123/2017 H-3 17,383 +/- 366 17,243 10,346
  • 24,140 Pass SPW-232 1/19/2017 H-3 17,542 :t: 368 17,243 10,346
  • 24,140 Pass SPW-304 1/26/2017 H-3 17,782 :t 400 17,243 10,346 - 24,140 Pass SPW-333 1/30/2017 H-3 17,910 :t 406 17,243 10,346
  • 24. 140 Pass SPW-353 2/2/2017 U-234 47.8 :t2.3 41.7 33.4 - 50.0 Pass SPW-353 2/2/2017 U-238 50.4 :t 2.4 41.7 33.4
  • 50.0 Pass W-020217 4/29/2016 Cs-134 33.7 :t 6.1 36.2 29.0 -43.4 Pass W-020217 4/29/2016 Cs-137 78.4 i 7.3 71.9 57.5
  • 86.3 Pass SPW-412 2/6/2017 Sr-90 36.2 :t: 2.4 36.6 29.3 - 43.9 Pass SPW-465 2/8/2017 H-3 17,573 :t 396 17,243 10,346
  • 24,140 Pass SPW-561 2/15/2017 H-3 17,358 :t 395 17,243 10,346 - 24,140 Pass SPW-605 2/16/2017 H-3 17,820 +/- 401 17,243 10,346
  • 24,140 Pass SPW-657 2/17/2017 H-3 17,614 :t 376 17,243 10,346
  • 24,140 Pass SPW-714 2/23/2017 H-3 17,662 :t 400 17,243 10,346 - 24,140 Pass SPW-737 2/28/2017 H-3 17,196 :t 395 17,243 10,346 - 24,140 Pass SPAP-740 2/28/2017 Gr. Beta 38.9 :t 0. 1 41.5 33.2 - 49.8 Pass SPAP-742 2/24/2017 Cs-134 1.05 :t 0.60 0.98 0.78 -1.18 Pass SPAP-742 2/24/2017 Cs-137 90.4 :t 2.5 92.9 74.3 - 111.5 Pass SPW-746 2/28/2017 Sr-90 42.8 :t 2.5 36.6 29.3
  • 43.9 Pass SPW-748 2/28/2017 C-14 4270 :t 17 4735 3788
  • 5682 Pass SPW-750 2/28/2017 Ni-63 463 :t 4 400 240 - 560 Pass SPF-752 2/28/2017 Cs-134 1033 +/- 38 1090 870
  • 1300 Pass SPF-752 2/28/2017 Cs-137 3071 :t 61 2820 2250
  • 3380 Pass SPW-781 3/1/2017 Ra-226 18.1 :t 0.4 16.7 13.4 - 20.1 Pass SPW-783 311/2017 H-3 17,653 :t 400 17,243 13,794 - 20,692 Pass W-030517 4/29/2016 Cs-134 38.0 :t 9.0 36.2 29.0 - 43.4 Pass W-030517 4/29/2016 Cs-137 80.9 :t 9.2 71.9 57.5
  • 86.3 Pass SPW-1010 3114/2017 H-3 17,312 :t 395 17,243 13,794
  • 20,692 Pass SPW-1026 3/16/2017 Gr. Alpha 22.4 :t 0.5 20.1 12.0 - 28.1 Pass SPW-1026 3/16/2017 Gr. Beta 29.2 :t 0.3 28.9 17.3 - 40.4 Pass SPW-1092 3/21/2017 H-3 17,252 :t 390 17,243 13,794 - 20,692 Pass SPW-1151 3/24/2017 H-3 17,009 :t 388 17,243 13,794
  • 20,692 Pass SPW-1163 3/28/2017 Sr-90 39.0 :t 2.3 36.3 29.0 - 43.5 Pass SPW-1178 3/29/2017 Ra-228 15.1 :t 1.9 16.0 9.6
  • 22.4 Pass A3-1

1 2 1 TABLE A-3. In-House "Spiked* Samples Concentration

  • Lab Code b Date Analysis Laboratory results Known Control 2s, n=1
  • Activity Llmitsd Acceptance SPW-1232 3/30/2017 H-3 17, 150 :t 390 17,243 13,794
  • 20,692 Pass SPW-1246 3/3112017 1-131(G) 33.0 :t 7.3 36.6 29.3 - 43.9 Pass SPW-1246 3131/2017 Cs-134 28.9 :t 4.6 26.6 21.3
  • 31.9 Pass SPW-1246 3/31/2017 Cs-137 80.6 t 8.2 70.4 56.3
  • 84.5 Pass SPMl-1248 313112017 1-131(G) 39.8 t 7.0 36.6 29.3 -43.9 Pass SPMJ-1248 3/31/2017 Cs-134 26.9 :t 5.9 26.6 21.3
  • 31.9 Pass SPMl-1248 3131/2017 Cs-137 70.4 t 6.9 70.4 56.3 - 84.5 Pass SPMl-1248 3/31/2017 1-131 36.2 :t 0.6 36.6 29.3
  • 43.9 Pass SPW-1295 3131/2017 Ra-226 17.9 :t 0.4 16.7 13.4 - 20.1 Pass SPW-1304 4/412017 H-3 17.741 :t 398 17.243 13,794
  • 20,692 Pass SPW-1359 4/5/2017 1-131 44.3 :t 0.5 47.6 38.1
  • 57.1 Pass SPW-1378 417/2017.

H-3 17,528 :t 395 17,243 13,794

  • 20,692 Pass SPW-1391 417/2017 Gr. Alpha 21.1 :t: 0.4 20.1 12.0
  • 28.1 Pass SPW-1391 41712017 Gr. Beta 27.8 :t 0.3 28.2 17.3
  • 40.4 Pass SPW-1480 4/12/2017 H-3 17,399 :t 392 17,243 13,794
  • 20,692 Pass W-041317 4/29/2016 Cs-134 34.6 t 5.6 36.2 29.0 - 43.4 Pass W-041317 4/29/2016 Cs-137 81.9 :t 8.0 71.9 57.5
  • 86.3 Pass SPW-1480 4/12/2017 H-3 17,399 :t: 392 17,243 13,794
  • 20,692 Pass SPW-1575 4/18/2017 H-3 17,419 :t: 393 17,243 13,794
  • 20,692 Pass SPW-1626 4/20/2017 Sr-90 37.2 :t 2.4 36.3 29.0 -43.5 Pass SPW-1658 4/21/2017 H-3 17,194 +/- 391 17,243 13,794 - 20,692 Pass SPW-1776 4/26/2017 H-3 16,609 :t: 386 17,243 13,794
  • 20.692 Pass SPW-1806 4/27/2017 H-3 17,203 :t 390 17,243 13,794 - 20,692 Pass SPW-1937 5/3/2017 H-3 16,690 :t 385 17,243 13,794
  • 20,692 Pass SPW-1971 5/512017 Sr-90 41.5 :t 2.2 36.3 29.0
  • 43.5 Pass SPW-2033 5/8/2017 H-3 16,780 :t: 386 17,243 13,794
  • 20.692 Pass SPW-2420 5/9/2017 Ra-226 16.3 :t: 0.5 16.7 13.4 - 20.1 Pass W-051517 4/29/2016 Cs-134 36.3 t 5.0 36.2 29.0 -43.4 Pass W-051517 4/29/2016 Cs-137 68.9 :t 6.6 71.9 57.5
  • 86.3 Pass SPW-2284 5/22/2017 H-3 16,935 +/- 389 16,703 13,362 - 20,043 Pass SPW-2354 5/23/2017 H-3 17,006 :t 390 16,700 13,360 - 20,040 Pass SPW-2891 5/23/2017 Ra-226 17.5 :t: 0.4 16.7 13.4 - 20.1 Pass SPW-2418 5/23/2017 Ra-228 14.0 +/- 1.8 16.0 11.2 - 20.8 Pass SPW-2439 5/25/2017 Ra-228 13.0 t 1.8 16.0 11.2 - 20.8 Pass SPMl-2378 5/24/2017 Sr-89 83.7 :t 4.9 98.4 78.7
  • 118.1 Pass SPMl-2378 5/24/2017 Sr-90 39.5 :t 1.5 36.1 28.9
  • 43.4 Pass SPW-2468 5/26/2017 H-3 17,065 :t: 391 16,692 13,354 - 20.031 Pass SPW-2848 5/2612017 1-131 56.4 :t 0.6 58.3 46.6 - 70.0 Pass SPW-2502 6/112017 H-3 17,596 i 396 16,677 13,342
  • 20,012 Pass SPW-2659 6/5/2017 H-3 17,027 :t 390 16,677 13,342
  • 20,012 Pass SPW-2790 6/9/2017 H-3 17,101 :t: 392 17,101 13,325 - 19,988 Pass A3-2

1 ) )

TABLE A-3. Jo-House "Spikeci-Samples Concentration*

Lab Code 1>

Data Analysis Laboratoiy results Known Control 2s,n=1c Activity Limits d Acceptance SPW-2798 6/12/2017 H-3 16,683 +/- 364 16,649 13,319 - 19,978 Pass SPW-2943 6/1912017 Sr-90 39.2 :t 2.3 36.1 28.9 -43.4 Pass SPW-3509 6/15/2017 Ra-226 17.6 :t 0.5 16.7 13.4

  • 20.1 Pass W-061317 4/29/2016 Cs-134 35.0 :t 6.2 36.2 29.0
  • 43.4 Pass W-061317 4/29/2016 Cs-137 77.4 +/- 7.8 71.9 57.5 - 86.3 Pass SPW-3041 6/23/2017 H-3 16,419 :t 378 16.620 13,296
  • 19,945 Pass SPW-3511 612312017 Ra-226 15.5 :t 0.6 16.7 13.4
  • 20.1 Pass SPW-3103 6/28/2017 H-3 16,507 :t 380 16,507 13,286 - 19,929 Pass SPW-3117 6/2912017 Tc-99 112.7 :t 1.9 107.8 86.2 - 129.4 Pass SPW-3513 6/2912017 Ra-226 17.8 :t 0.5 16.7 13.4
  • 20.1 Pass SPW-3188 713/2017 Sr-90 38.1 :t 2.2 36.1 28.9
  • 43.4 Pass SPW-3283 7/11/2017 H-3 16,057 :t 347 16,649 13,319
  • 19,978 Pass SPW-4054 7/1112017 Ra-226 17.7 :t 0.4 16.0 11.2 - 20.8 Pass SPW-3467 7/1412017 Gr. Alpha 22.3 :t 0.5 20.1 12.0
  • 28.1 Pass SPW-3467 7/14/2017 Gr. Beta 29.1 :t 0.3 28.2 17.3 -40.4 Pass SPW-3449 7/15/2017 H-3 17,196 :t 393 16,507 13,286 - 19,929 Pass SPW-3546 7/19/2017 H-3 16,764 :t 386 16,507 13,286
  • 19,929 Pass SPW-3728 7/24/2017 H-3 16,117 :t 354 16,507 13,286 - 19,929 Pass SPW-3794 7128/2017 H-3 16,645 :t 384 16,507 13,286 - 19,929 Pass W-072817 4/29/2016 Cs-134 38.6 :t 5.6 36.2 29.0
  • 43.4 Pass W-072817 4/29/2016 Cs-137 76.5 :t 7.6 71.9 57.5 -86.3 Pass SPW-3905 8/3/2017 Gr. Alpha 22.3 :t 0.5 20.1 12.0 - 28.1 Pass SPW-3905 813/2017 Gr. Beta 27.6 :t 0.3 28.2 17.3 -40.4 Pass SPW-4030 8/912017 H-3 17,636 :t 403 16,507 13,286 - 19,929 Pass SPW-4086 8/14/2017 H-3 17,472 :t 401 16,507 13,286
  • 19,929 Pass SPW-4207 8/1712017 H-3 17,013 :t 393 16,507 13,286
  • 19,929 Pass W-083017 4129/2016 Cs-134 34.7 :t 6.4 36.2 29.0 - 43.4 Pass W-083017 4/29/2016 Cs-137 78.2 :t 6.7 71.9 57.5
  • 86.3 Pass SPW-4241 8/19/2017 H-3 17.222 :t 371 16.507 13,286 - 19,929 Pass SPW-4458 9/112017 Ra-226 14.1 :t1.8 16.7 13.4
  • 20.1 Pass SPW-4466 9/612017 Sr-89 22.8 :t 8.5 26.4 21.1 -31.7 Pass SPW-4466 9/6/2017 Sr-90 32.5 :t 2.1 33.8 27.0
  • 40.6 Pass SPW-4512 9/8/2017 Gr. Alpha 19.2 +/- 0.4 20.1 10.1
  • 30.2 Pass SPW-4512 9/8/2017 Gr. Beta 27.6 +/-0.3 27.9 22.3 - 33.5 Pass SPW-4586 919/2017 H-3 16,586 :t 362 16,507 13,286 - 19,929 Pass SPW-4720 9/16/2017 H-3 16,439 ::t 362 16,507 13,286
  • 19,929 Pass SPW-4834 9/22/2017 H-3 16,238 :t 378 16,507 13,286 - 19,929 Pass SPW-4935 9/2712017 H-3 16,595 ::t 381 16,507 13,286
  • 19,929 Pass SPW-4937 9/2712017 Ra-228 5.7 t 0.9 5.8 4.1 -7.5 Pass W-092717 4129/2016 Cs-134 36.0 t 5.9 36.2 29.0 - 43.4 Pass W-092717 4129/2016 Cs-137 82.6 :t:8.5 71.9 57.5 - 86.3 Pass SPW-5001 9129/2017 H-3 16,446 :t 358 16,507 13,286
  • 19,929 Pass A3-3

TABLE A-3. In-House "Spiked" Samples Concentration

  • Lab Code b Date Analysis Laboratory results Known Control 2s, n=1
  • Activi!}'.

Limits d Acceetance SPW-5134 10/6/2017 H-3 16,128 :t: 373 16,507 13,286 -19,929 Pass SPW-5274 10/12/2017 H-3 16,108 t 374 16,507 13,286 -19,929 Pass W-101217S 10/12/2017 Fe-55 1,491 +/- 77 1,482 1,186-01,778 Pass SPW-5408 10/18/2017 Ni-63 203 :t: 3 199 159 - 238 Pass SPW-5430 10/19/2017 H-3 16,453 :t: 380 16,507 13,286 - 19,929 Pass W-102017 4/29/2016 Cs-134 31.3+/-4.9 36.2 29.0 - 43.4 Pass W-102017 4/29/2016 Cs-137 80.4 +/- 6.9 71.9 57.5 -86.3 Pass SPW-5674 10/25/2017 H-3 16,313 :t: 380 16,507 13,286 - 19,929 Pass SPW-5719 10/27/2017 H-3 16,113 :t: 350 16.507 13,286 - 19.929 Pass SPW-5730 10/31/2017 H-3 16,776 :t: 387 16,507 13,286 - 19,929 Pass SPW-5944 10/2712017 Ra-226 16.4 +/- 0.5 16.7 13.4 - 20.1 Pass SPW-5915 11/9/2017 H-3 16,930 :t: 390 16,507 13,286 - 19,929 Pass SPW-5989 11/11/2017 H-3 16,084 :t: 352 16,507 13,286

  • 19,929 Pass W-111417 4/29/2016 Cs-134 38.1 +/- 6.2 36.2 29.0 - 43.4 Pass W-111417 4/29/2016 Cs-137 74.0 +/- 7.5 71.9 57.5 - 86.3 Pass SPW-6121 11/1612017 H-3 16,276 +/- 378 16,507 13,286 - 19,929 Pass SPW-6132 11/20/2017 H-3 15,897 :t: 374 16,507 13,286 - 19,929 Pass SPW-6249 11/30/2017 Ra-226 12.2 :t: 0.4 12.3 9.8
  • 14.8 Pass SPW-6226 12/1/2017 H-3 16,164 t 378 16,507 13,286 - 19,929 Pass SPW-6318 12/7/2017 H-3 15,779 +/- 372 16,507 13,286 - 19,929 Pass W-120817 4/29/2016 Cs-134 29.5 +/- 5.6 36.2 29.0
  • 43.4 Pass W-120817 4/29/2016 Cs-137 78.8 :t 9.6 71.9 57.5 - 86.3 Pass SPW-65 12/11/2017 Ra-226 12.5 :t: 0.4 12.3 9.8
  • 14.8 Pass SPW-6437 12/13/2017 Gr. Alpha 19.6 :t: 0.4 20.1 10.1
  • 30.2 Pass SPW-6437 12/13/2017 Gr. Beta 28.2 +/- 0.3 27.9 22.3 - 33.5 Pass SPW-6463 12/15/2017 H-3 15,560 :t: 372 16,507 13,286
  • 19,929 Pass
  • Uquld sample results ere reported in pC4/Liter, sir fillera ( pCi/m3), charcoal (pCi/charcoal canister), end solid samples (pCi/kg).

b Laboratory codes : W (Water). Ml (milk), AP (air filler). SO (soil), VE (vegetation), CH (charcoal canister). F (fish). U (urine).

c ResullS ere t>aSed on single determinations.

4 Control Hmlts are established from the precision values listed in Attachment A of this report, adjusted to :1: 2s.

NOTE: For fish. gelatin is used for the spike matrix. For vegetation. cabbage is used for the spike matrix.

A3-4

, ) 4 TABLE A-4. In-House *arank" Samples Conc'i'ntration

  • Lab Code Sample Date Anatyslsl>

Laborato~ results !4.66al Acceptance Type LLD Activity~

Criteria (4.66 o)

SPW-31 Water 1/6/2017 H-3 143 71 :t: 75 200 SPW-45 Water 1/9/2017 Gr. Alpha 0.41 0.09 :t 0.30 2

SPW45 Water 1/912017 Gr. Beta 0.74

-0.56 :t 0.50 4

SPW-91 Water 1/11/2017 H-3 151

-23 :t 71

200, SPW-141 Water 1/12/2017 Sr-89 0.55 0.29 :t 0.47 5

SPW-141 Water 1/12/2017 Sr-90 0.67

-0.02 :t 0.31 1

SPW-154 Water 1/19/2017 H-3 155

-17 :t 73 200 SPW-185 Water 1/23/2017 H-3 176 44 :t 94 200 SPW-231 Water 1/19/2017 H-3 179 26 :t 87 200 SPW-303 Water 1/26/2017 H-3 160 8 -t. 77 200 SPW-305 Water 1/4/2017 Ra-226 0.02 0.02 :t 0.01 2

SPW-307 Water 1/27/2017 1-131 0.21 0.01 :t 0.11 1.00 SPW-332 Water 1/30/2017 H-3 169

-52 :t 86 200 SPW-352 Water 2/2/2017 U-234 0.14 0.00 :t 0.08 SPW-352 Water 2/212017 U-238 0.14 0.12 :t: 0.15 1

SPW411 Water 2/6/2017 Sr-89 0.49 0.30 :t: 0.35 5

SPW411 Water 2/6/2017 Sr-90 0.52

-0.22 :t 0.21 1

SPW464 Water 2/812017 H-3 155 2 :t 74 200 SPW-560 Water 2/15/2017 H-3 156 38 :t 77 200 SPW-604 Water 2/16/2017 H-3 154 59 :t 77 200 SPW-656 Water 2/17/2017 H-3 187 28 t 94 200 SPW-713 Water 2/23/2017 H-3 161 20 i 81 200 SPW-736 Water 2/2812017 H-3 161

-75 :t 76 200 SPAP-739 AP 2/28/2017 Gr. Beta 0.002 0.004 :t 0.001 0.01 SPAP-741 AP 2/24/2017 Cs-134 2.27

-0.95 :t: 1.29 100 SPAP-741 AP 2/2412017 Cs-137 2.65 0.17 :t 1.67 100 SPW-747 Water 2/28/2017 C-14 161

-28 :t 97 200 SPW-749 Water 2/28/2017 Ni-63 17

-3 :t 10 200 SPF-751 Fish 2/28/2017 Cs-134 0.008 0.002 :t 0.004 100 SPF-751 Fish 2/28/2017 Cs-137 0.008 0.000 :t 0.005 100 SPW-780 Water 3/1/2017 Ra-226 0.02 0.02 :t 0.01 2

SPW-782 Water 3/1/2017 H-3 154 35 :t 78 200 SPW-3506 Water 3/1/2017 Ra-226 0.03 0.02 :t 0.02 2

SPW-836 Water 3/3/2017 1-131 0.38 0.04 :t 0.18 1

SPW-1009 Water 3/14/2017 H-3 154

-31 :t 72 200 SPW-1025 Water 3/16/2017 Gr. Alpha 0.43

-0.16 :t 0.28 2

SPW-1025 Water 3/16/2017 Gr. Beta 0.75

--0.24 :t 0.52 4

SPW-1091 Water 3121/2017 H-3 145 60 :t: 73 200 SPW-1150 Water 3/24/2017 H-3 152

-31 :t 71 200 SPW-1162 Water 3/2812017 Sr-89 0.61

-0.39 :t 0.45 5

SPW-1162 Water 3/2812017 Sr-90 0.52 0.18 :t 0.27 1

  • Liquid sample resulls are reported in pCi/Uter, air fillers ( pCi/m3), charcoal (pCi/charcoal canister), end solid samples (pCl/g).

b l-131(G): lodine-131 es analyzed by gamma spectroscopy.

  • Activity reported Is a net actMty result.

A4-1

1 2 5 TABLE A-4. In-House *eIank" Samples Concentration

  • Lab Code Sample Date Analysisb Laborato~ results (4.66al Acceptance Type LLD Activltf Criteria (4.66 a)

SPW-1177 Water 3/2912017 Ra-228 0.83

-0.14.t 0.36 2

SPW-1231 Water 3/3012017 H-3 150 24 :t: 73 200 SPW-1245 Water 3/31/2017 Cs-134 3.73 0.43 :t 2.18 100 SPW-1245 Water 3/31/2017 Cs-137 3.01

-1.23 :t 2.12 100 SPW-1245 Water 3/31/2017 1-131(G) 5.39 0.92 :t 2.15 100 SPW-1245 Water 3/31/2017 i-131 0.32 0.03 +/- 0.18 1

SPMl-1247 Milk 3/31/2017 Cs-134 3.70 1.23 +/- 1.96 100 SPMJ-1247 Milk 3/31/2017 Cs-137 3.62

-0.84 :t 2.15 100 SPMl-1247 Milk 3/31/2017 J-131 (G) 4.42 0.39.t 2.14 100 SPW-1294 Water 3/3112017 Ra-226 0.02 0.18 :t 0.02 2

SPW-1303 Water 4/4/2017 H-3 151 8 +/- 75 200 SPW-1377 Water 4(7/2017 H-3 150 29 :t: 72 200 SPW-1390 Water 4(7/2017 Gr. Alpha 0.42 0.15 +/- 0.31 2

SPW-1390 Water 4/712017 Gr. Beta 0.73

-0.17 :t: 0.51 4

SPW-1479 Water 4/12/2017 H-3 151 89 :t: 77 200 SPW-1574 Water 4/1812017 H-3 144 55 :t: 79 200 SPW-1625 Water 4/2012017 Sr-89 0.59

-0.01 +/- 0.50 5

SPW-1625 Water 4/2012017 Sr-90 0.71 0.16 t 0.35 1

SPW-1657 Water 4/21/2017 H-3 147 34 +/- 73 200 SPW-1775 Water 4/26/2017 H-3 155 67 :t 80 200 SPW-1805 Water 4127/2017 H-3 153 15 :t: 74 200 SPW-1936 Water 5/312017 H-3 148 33 :t 71 200 SPW-1970 Water 5/5/2017 Sr-89 0.66 0.34 :t: 0.54 5

SPW-1970 Water 5/5/2017 Sr-90 0.62

-0.08 :t 0.28 1

SPW-2032 Water 5/8/2017 H-3 147 66 :t. 73 200 SPW-2419 Water 51912017 Ra-226 0.03 0.01 +/-0.03 2

SPW-2283 Water 5/22/2017 H-3 155 24 +/- 78 200 SPW-2353 Water 5/23/2017 H-3 151 56 +/-76 200 SPW-2890 Waler 5/23/2017 Ra-226 0.03

-0.01 :t 0.02 2

SPMJ-2377 Milk 5/24/2017 Sr-89 0.78 0.86 :t 0.93 5

SPMl-2377 Milk 5/24/2017 Sr-90 0.49 0.95 t 0.33 1

SPW-2438 Water 5125/2017 Ra-228 0.90

-0.28 +/- 0.38 2

SPW-2467 Water 5/26/2017 H-3 152 27 +/- 77 200 SPW-2417 Water 5/26/2017 Ra-228 0.80 1.58 :t 0.54 2

SPW-2447 Water 5/2612017 1-131 0.21

-0.05 :t 0.12 1

SPW-2501 Water 611/2017 H-3 151

  • 23 :t: 70 200 SPW-2658 Water 6/512017 H-3 152 107 +/- 78 200 SPW-2789 Water 6/9/2017 H-3 150 52 +/-77 200 SPW-2797 Water 6112/2017 H-3 177 7.t 93 200 SPW-2847 Water 6/14/2017 1-131 0.18 0.03 +/- 0.10
  • Liquid sample results are reported in pCi/Liter, air fillers ( pCi/m3). charcoal (pCl/charcoal canister). and solid samples (pCl/g).

~ 1-131(G); lodin&-131 as analyzed by gamma spectroscopy.

e Activity reported is a nel activity result.

A4-2

1 ? fi TABLE A-4. In-House *eIank" Samples Concentration

  • Lab Code Sample Data Analysis" Laborato!i'. results {4.66c:Jl Acceptance Type LLD Activity' Criteria (4.66 a)

SPW-3508 Water 6/15/2017 Ra-226 0.03 0.00 :t 0.02 2

SPW-2942 Water 6/19/2017 Sr-89 0.58 0.80.t 0.53 5

SPW-2942 Water 6/19/2017 Sr-90 0.50 0.15 t 0.25 1

SPW-3042 Waler 6/23/2017 H-3 146 25 t 74 200 SPW-3510 Water 6123/2017 Ra-226 0.02 0.03.t 0.02 2

SPW-3102 Weter 6/28/2017 H-3 148

-7.t 73 200 SPW-3116 Weter 6/29/2017 Tc-99 5.91

-0.39 :t 3.58 10 SPW-3512 Water 6/29/2017 Ra-226 0.02

-0.01.t 0.02 2

SPW-3187 Water 713/2017 Sr-89 0.62 0.00 :t 0.48 5

SPW-3187 Water 7/3/2017 Sr-90 0.48 0.07 :t 0.23 1

SPW-3282 Water 7/11/2017 H-3 178

-37.t 84 200 SPW-4053 Water 7/11/2017 Ra-226 0.03 0.02 :t 0.02 2

SPW-3466 Water 7/14/2017 Gr. Alpha 0.42

-0.09.t 0.26 2

SPW-3466 Water 7/14/2017 Gr. Beta 0.76

-0.18.t 0.53 4

SPW-3448 Water 7/15/2017 H-3 150 54 :t 77 200 SPW-3727 Water 7/27/2017 Ni-63 90 18 :t 55 200 SPW-3793 Water 7/28/2017 H-3 151 47 :t:82 200 SPW-3904 Water 8/3/2017 Gr. Alpha 0.47

-0.02 :t 0.33 2

SPW-3904 Water 8/3/2017 Gr. Beta 0.75

-0.11 t 0.52 4

SPW-4029 Waler 819/2017 H-3 159 11 t 79 200 SPW-4206 Water 8/17/2017 H-3 157 55.t 76 200 SPW-4241 Water 8/19/2017 H-3 190 61 :t 96 200 SPW-4085 Water 8/14/2017 H-3 159

-28 :t 77 200 SPW-4206 Water 8/17/2017 H-3 157 55 :t 76 200 SPW-4241 Water 8/19/2017 H-3 190 61 :t 96 200 SPW-4457 Water 9/1/2017 Re-228 0.78

-0.02 :t 0.36 2

SPW-4465 Water 9/6/2017 Sr-89 0.51 0.30.t 0.37 5

SPW-4465 Water 9/6/2017 Sr-90 0.46

-0.09 :t 0.20 1

SPW-4585 Water 9/9/2017 H-3 187

-86 :t83 200 SPW-5720 Water 9/13/2017 Ra-226 0.02 0.13 :t 0.02 2

SPW-4703 Water 9/15/2017 1-131 0.17 0.10 :t 0.10 1

SPW-4719 Water 9/1612017 H-3 184

-86 :t 93 200 SPW-4833 Water 9/22/2017 H-3 150 5.t 72 200 SPW-4934 Water 9/27/2017 H-3 148 5 :t 70 200 SPW-4936 Weter 9/27/2017 Ra-228 0.80 0.55 :t 0.44 2

SPW-5000 Water 9/29/2017 H-3 183

-13 :t 90 200 SPW-5133 Water 10/612017 H-3 144 64 t 71 200 SPW-5273 Water 10/12/2017 H-3 142 106 :t 72 200

  • Uquid sample results are reported in pCi/Liler, air filters ( pCi/m3). charcoal (pCi/chercoal canister), and solid samples (pCi/g).

b 1-131(G); iodine-131 es analyzed by gamma spectroscopy.

0 ActMty reported is a net activity result.

TABLE A-4. In-House *eIank* Samples Concontralion

  • Lab Code Sample Date Analysist>

Laborato~ results (4.66oj Acceptance Type LLD Activllyc:

Criteria (4.66 a)

SPW-5407 Water 10/18/2017 Ni-63 69 43 :t 43 200 SPW-5429 Water 10/19/2017 H-3 148 54 i 72 200 SPW-5603 Water 10/23/2017 Sr-89 0.57 0.16 t 0.47 5

SPW-5603 Water 10123/2017 Sr-90 0.70

-0.12 i 0.31 1

SPW-5673 Water 10/25/2017 H-3 156

-36 :t 71 200 SPW-5718 Water 10/27/2017 H-3 182 45 :t 92 200 SPW-5943 Water 10/27/2017 Ra-226 0.02 0.08 t 0.02 2

SPW-5723 Water 10/30/2017 1-131 0.10 0.03 t 0.07 SPW-5914 Water 11/09/17 H-3 149

-39 :t 68 200 SPW-5988 Water 11/11/2017 H-3 183

..a :t 88 200 SPW-6120 Water 11/16/2017 H-3 146 83 i75 200 SPW-6131 Water 11/20/2017 H-3 151 16 t 72 200 SPW-6197 Water 11/2912017 1-131 0.36 0.01 t 0.18 1

SPW-6248 Water 11/3012017 Ra-226 0.03 0.15 :t 0.03 2

SPW-6225 Water 12/1/2017 H-3 154

-10 :t 72 200 SPW-6317 Water 12/7/2017 H-3 148 44 :t 74 200 SPW-64 Water 12/11/2017 Ra-226 0.03 0.18 t0.03 2

SPW-6436 Water 12/1312017 Gr. Alpha 0.54

-0.17 :t 0.37 2

SPW-6436 Water 12/13/2017 Gr. Beta 0.74 0.12 :t 0.52 4

SPW-6464 Water 12/15/2017 H-3 148 31 t 75 200

  • Liquid sample restilts ere reported in pCilUter, air filters ( pCUm'). charcoal (pCi/charcoal canister), and solid samples (pCi/g).

b l-131(G): iOdine-131 as anafyzed by gamma spectroscopy.

  • Activity reported is a net activity result.

A4-4 1 J 7

1 2 ~

TABLE A-5. In-House "Duplicate" Samples Concentration

  • Averaged Lab Code Date Analysis First Result Second Result Result Acceptance AP-7178,7179 1/3/2017 Be-7 0.047 +/- 0.015 0.062 :t 0.017 0.054 :t: 0.012 Pass SW-6986,6987 1/3/2017 Gr. Beta 1.39 +/- 0.41 0.77 :t 0.41 1.08 +/- 0.29 Pass E-66,67 1/3/2017 Gr. Bela 1.62 :t 0.05 1.45 :t 0.04 1.54 :t 0.11 Pass E-66,67 1/3/2017 K-40 1.26 :t 0.14 1.39 :t 0.16 1.32 :t 0.11 Pass CF-87,88 1/3/2017 Be-7 0.25 :t 0.11 0.30 :t 0.12 0.28 :t 0.08 Pass CF-87,88 1/3/2017 K-40 7.77 +/- 0.39 6.84 t0.37 7.31 :t 0.27 Pass AP--011217 1/12/2017 Be-7 0.137 +/- 0.078 0.139 :t: 0.082 0.136 +/- 0.056 Pass Ml-212,213 1/16/2017 K-40 1,515 :t 98 1,347 +/- 107 1,431 +/- 73 Pass WW-321,322 1/19/2017 H-3 675 :t 118 506 :t 133 590 :t 89 Pass WW-674.675 1120/2017 H-3 7,326 +/- 254 7,717 :t 259 7.522 :t 181 Pass AP-012317 1/23/2017 Gr. Beta 0.034 t 0.005 0.038 :t: 0.005 0.036 :t 0.004 Pass WW-298,299 1/24/2017 H-3 5,916 :t: 239 5764 :t 237 5840 +/- 168 Pass AP--013117 1/30/2017 Gr. Beta 0.027 :t: 0.004 0.028 +/- 0.004 0.028 t 0.003 Pass WW-500,501 1/31/2017 H-3 1,058 :t 122 1,054 :t 121 1,056 :t 86 Pass SW-391,392 1/31/2017 Gr. Beta 1.40 :t 0.56 1.62 :t 0.61 1.51 :t 0.41 Pass SPS-370,371 2/1/2017 K-40 23.47 :t 0.66 23.11 t 0.72 23.29 :t0.49 Pass AP-456,457 2/2/2017 Be-7 0.129 :t0.076 0.167 :t: 0.092 0.148 ::t: 0.060 Pass AP--020217 21212017 Gr. Beta 0.021 :t: 0.004 0.027 :t 0.004 0.024 :t 0.003 Pass SPs-414.415 2/3/2017 K-40 19.45 :t: 1.85 21.58 :t 1.99 20.52 :t 1.36 Pass AP--020617 2/6/2017 Gr. Beta 0.023 :t 0.004 0.023 :t: 0.004 0.023 :t: 0.003 Pass AP--021417A 2/14/2017 Gr. Beta 0.031 t 0.004 0.030 :t 0.004 0.030 :t: 0.003 Pass SPW-543 2/14/2017 Gr. Bela 7.99 :t 0.82 9.45 :t 0.88 8.72 +/- 0.60 Pass AP--0214178 2/14/2017 Gr. Beta 0.024 :t: 0.004 0.028 :t 0.004 0.026 :t 0.003 Pass WW-718,719 2/14/2017 H-3 737 :t 113 643:+/-110 690 :t 79 Pass AP--022017 2/20/2017 Gr. Beta 0.018 :t 0.005 0.021 :t 0.005 0.020 :t 0.004 Pass WW-755,756 2/22/2017 H-3 3,709 :t 196 3,823 :t 198 3,766 ::t: 139 Pass AP--022717 2/27/2017 Gr. Beta 0.021 :t 0.004 0.019 +/- 0.004 0.020 :t 0.003 Pass SPOW-80011,2 3/2/2017 Ra-226 7.29 :t 0.32 6.76 +/- 0.30 7.03 +/- 0.22 Pass SPOW-80011,2 3/2/2017 Ra-228 4.68 :t 0.82 6.29 :t 1.03 5.49 :t 0.66 Pass SPOW-80013,4 3/2/2017 Gr. Alpha 13.57 :t 1.43 12.44 :t 1.37 13.01 +/- 0.99 Pass WW-845,846 3l2J2017 H-3 314 t 93 249 +/- 90 281 t65 Pass AP--030617 3/612017 Gr. Beta 0.022 +/- 0.004 0.019 +/- 0.004 0.020 :t 0.003 Pass WW-1050,1051 318/2017 H-3 14,994 :t 364 14,745 :t 362 14,870 :t 257 Pass SPS-920.921 319/2017 K-40 23.30 +/- 1.76 23.13 :t 1.64 23.21 :t 1.20 Pass WW-1004,1005 3/13/2017 H-3 182 +/- 80 158 t 79 170 +/-56 Pass SPS-1029, 1030 3115/2017 K-40 11.82 :t 0.68 12.01 :t 0.68 11.92 :t 0.48 Pass AP--031517 3115/2017 Gr. Beta 0.020 :t 0.003 0.020 :t 0.003 0.020 :t 0.002 Pass SPDW-80037,8 3120/2017 Gr. Alpha 4.54 t0.82 5.29 :t 0.91 4.91 :t 0.61 Pass AP--032017 3/20/2017 Gr. Bet~

0.021 t 0.006 0.021 t 0.006 0.021 +/- 0.005 Pass WW-1094,1095 3120/2017 H-3 1,571 :t 137 1,595 :t 138 1,583 :t 175 Pass A5-1

TABLE A-5. In-House "Duplicate" Samples Concentration

  • Averaged Lab Code Date Analysis First Result Second Result Result Acceptance WW-1175, 1176 3/20/2017 H-3 218 :t 84 211 :t 84 214 :t 59 Pass WW-1129, 1130 312112017 Gr. Beta 3.51 +/- 1.24 2.99 :t 1.17 3.25 :t 0.65 Pass WW-1219,1220 3122/2017 H-3 11,467 +/- 322 11,516 :t 323 11,492 :t 200 Pass SPS-1152, 1153 3/27/2017 Ac-228 20.39 :t 0. 75 20.43 :1: 0.88 20.41 :t 0.58 Pass SPS-1152,1153 3/27/2017 Pt>-214 17.22 +/- 0.50 16.44 ::1: 0.52 16.83 +/-0.36 Pass SPDW-80047,8 3/28/2017 Ra-226 2.06 :t 0.23 1.60 +/- 0.32 1.83 :t 0.20 Pass SPDW-80047,8 3/28/2017 Ra-226 0.53 :t0.48 0.78 +/- 0.49 0.66 :t 0.34 Pass SWU-1242,1243 3/28/2017 Gr. Beta 2.04 +/-0.81 2.47 +/- 0.69 2.26 :t 0.53 Pass SPS.1198, 1199 3/29/2017 K-40 16.95 :t 1.85 18.33 ::1: 1.71 17.64 :t 1.26 Pass SPDW-80050, 1 3/29/2017 Gr. Alpha 3.19 :t 0.80 3.39 :t 0.78 3.29 :t 0.56 Pass SPOW-80050, 1 3129/2017 Gr. Beta 1.58 :t 0.60 2.08 :t 0.63 1.83 t 0.44 Pass AP-1706, 1707 3130/2017 Be-7 0.068 t 0.018 0.072 :t 0.017 0.070 +/- 0.012 Pass SW-1381,1382 4/512017 H-3 402 +/- 92 309 :t 88 356 +/- 64 Pass WW-1446, 1447 4/6/2017 H-3 305 :t 89 358 :t 91 332 +/- 64 Pass WW-1532.1533 4/1012017 H-3 19,124 +/-412 18,991 :t 410 19,058 :t 291 Pass WW-1618, 1619 4/12/2017 H-3 4,187+/-203 4,305 :t 205 4,246 +/- 144 Pass SS-1553.1554 4/13/2017 Gr. Beta 7.16 :t 0.99 6.09 :t 0.91 6.63 +/- 0.67 Pass SS-1553, 1554 4/13/2017 K-40 4.60 :t 0.32 4.84 :t 0.34 4.72 :t 0.23 Pass SS-1553, 1554 4/13/2017 11-208 0.038 +/- 0.016 0.032 :t 0.011 0.035 :t 0.010 Pass SS-1553, 1554 4/13/2017 Pb-212 0.101 :t 0.015 0.096 :1: 0.015 0.098 +/- 0.010 Pass SS-1553,1554 4113/2017 B1-214 0.094 :t 0.032 0.109 :1: 0.022 0.101 +/- 0.019 Pass SS-1553, 1554 4/13/2017 Ac-228 0.089 :t 0.042 0.111 :t 0.046 0.100 :t 0.031 Pass P-2015,2016 5/4/2017 H-3 189 +/- 80 212 :t 81 200 :t 57 Pass WW-2336,2337 5/8/2017 H-3 422 :t 97 298 :t 91 360 :t 66 Pass AP-051117 5/11/2017 Gr. Beta 0.018 :t 0.003 0.025 :t 0.004 0.021 :t 0.002 Pass WW-2497,2498 5/23/2017 H-3 1,268 :t 127 1,247 :t 126 1,257 :t 89 Pass WW-2583,2584 5/23/2017 H-3 5,159 :t 224 5,223 :t 126 5,191 t 129 Pass WW-2732,2733 5/23/2017 H-3 8,559 :t 282 8,570 +/- 283 8,564 :t 200 Pass XW-1218,1219 5123/2017 H-3 11,467 :t: 282 11,516 +/- 283 11,492 :t 200 Pass Ml-2428,2429 5/24/2017 K-40 1,752 :t 137 1,805 +/- 132 1,778 :t 95 Pass S0-2562,2563 5/2412017 K-40 7.87 +/- 0.50 8.64 :t 0.49 8.25 +/- 0.35 Pass WW-3023,3024 5/24/2017 H-3 27,398 :t 486 27,733 :t 489 27,565 :t 344 Pass S0-2453,2454 5/25/2017 Gr. Beta 14.38 :1: 0.93 15.70 :t 1.06 15.04 +/- 0.70 Pass S0-2453,2454 5/25/2017 Cs-137 0.17 :t: 0.03 0.18 t 0.03 0.17 :t0.02 Pass S0-2453,2454 5/25/2017 K-40 9.80 :t 0.50 9.19 :t 0.57 9.50 +/- 0.38 Pass S0-2453,2454 5/25/2017 Tl-208 0.09 :t 0.02 0.10 :t 0.03 0.09 :t 0.02 Pass S0-2453,2454 5/25/2017 Pl>-212 0.29 :t 0.03 0.30 +/-0.03 0.29 :t 0.02 Pass S0-2453,2454 5125/2017 Bi-214 0.24 t 0.03 0.18 :t:0.04 0.21 :t 0.03 Pass S0-2453,2454 5125/2017 Ra-226 0.82 :t 0.22 0.62 :t 0.27 0.72 t 0.17 Pass S0-2453,2454 5/25/2017 Ac-228 0.32 t 0.07 0.28 :t 0.08 0.30 +/- 0.05 Pass A!i-?

TABLE A-5. In-House "Duplicate" Samples Concentration

  • Averaged Lab Code Date Analysis First Result Second Result Result Acceptance SWT-2625,2626 5/3012017 Gr. Beta 0.64 :t 0.53 1.08 +/- 0.55 0.86 :t 0.38 Pass AP-053117 5/31/2017 Gr. Beta 0.013 :t 0.003 0.011 :t 0.003 0.012 :t 0.002 Pass G-2646,2647 6/1/2017 Be-7 1.02 :t0.17 1.06 :t 0.26 1.04.t 0.15 Pass G-2646,2647 6/1/2017 K-40 7.51 :t 0.49 6.55 :1: 0.51 7.03 :t 0.36 Pass SL-2669,70 6/1/2017 Be-7 0.34 :t 0.06 0.30 :t 0.06 0.32 :t 0.04 Pass SL-2669.70 6/1(2017 K-40 4.35 :t 0.14 4.39 :t 0.15 4.37 :I: 0.10 Pass F-2711,2712 612/2017 K-40 2.56 :t 0.32 2.77 :t 0.44 2.66 :1: 0.27 Pass AP-060617 6/6/2017 Gr. Beta 0.026 :t 0.005 0.027 :t 0.005 0.027.t 0.004 Pass SW-2849,50 6/8/2017 H-3
8. 118 +/- 213 8,563 :t 279 8,371 :t 195 Pass AP-061217 6/12/2017 Gr. Beta 0.027 +/- 0.005 0.027 :t 0.005 0.027 :t 0.004 Pass BS-3446,3447 6/12/2017 K-40 8.30 :t 0.47 8.57 :t 0.47 8.44 :t 0.33 Pass VE-2870,2871 6/1312017 K-40 3.65 :t 0.25 3.90 :t 0.26 3.77 :t0.18 Pass AP-2914,5 6/15/2017 Be-7 0.269 :t 0.146 0.212 :t 0. 123 0.240 :t 0.095 Pass AP-3067,8 6/15/2017 Be--7 0.204 :t0.113 0.328 :t 0.126 0.266 :t 0.085 Pass AP-061917 6/1912017 Gr. Beta 0.020 :t 0.004 0.019.t 0.004 0.020 :t 0.003 Pass AP-3610,1 6/26/2017 Be-7 0.107 :t 0.015 0.116 :t 0.021 0.111 :t 0.013 Pass AP-062617 6/26/2017 Gr. Beta 0.017 :t 0.004 0.021 :t 0.004 0.019 :t 0.003 Pass AP-3673,3674 7/312017 Be-7 0.087 :t 0.008 0.078 :t 0.008 0.083 :t 0.006 Pass AP-3287,3288 7/612017 Be--7 0.207 :t 0.112 0.244 :t 0.096 0.226 :t 0.074 Pass WW-3308,3309 7nt2017 H-3 549 :t 108 501 :t 107 525 :t 76 Pass VE-3362,3363 7/12/2017 K-40 2.32 :t 0.17 2.40 :t 0.16 2.36 :t0.12 Pass VE-3589,3590 7/18/2017 K-40 5.25 :t0.33 4.64 :t 0.33 4.94 :t 0.23 Pass SG-3631,3632 7118/2017 Pl>-214 3.03 t 0.11 2.97 :t 0.11 3.00 :t 0.08 Pass SG-3631,3632 7/18/2017 Ac-228 2.47 :t 0.22 2.56 :t 0.23 2.52 :t0.16 Pass WW-3846,3847 7/25/2017 H-3 505 :t 101 446 :t 98 475 :t 70 Pass F-4509.4510 7/26/2017 K-40 0.85 :t 0.25 1.00 :t 0.25 0.93 t0.18 Pass F-4509,4510 7/26/2017 Gr. Beta 1.19 :t 0.03 1.18 :t 0.03 1.18 :t.0.02 Pass G-3804,3605 7/27/2017 Be-7 3.72 :1: 0.39 3.47 :I: 0.40 3.59 :t 0.28 Pass G-3804,3805 7/27n.017 K-40 4.21 :t 0.52 4.46 +/-0.52 4.34 :t 0.33 Pass SL-3888,3889 8/112017 Be-7 0.77 :t 0.04 0.73 :t 0.07 0.75 :t0.04 Pass SL-3888,3889 8/1/2017 K-40 0.94 t0.04 0.87 :t 0.08 0.90 :t0.23 Pass WW-4158,4159 8/812017 H-3 321 :t 90 270 :t 88 295 :t 63 Pass VE-4179,4180 8/14/2017 K-40 1.84 :1: 0.18 1.90 :t 0.21 1.87 :t0.14 Pass AP-4289,4290 8117/2017 Be-7 0.212 :t 0.095 0.162 :1: 0.080 0.187 :t 0.062 Pass F-4333,4334 8118/2017 K-40 3.22 :t 0.41 3.62 :t 0.42 3.42 :t 0.29 Pass CF-4310,4311 8/21/2017 K-40 10.94 :t 0.74 11.48 :t 0.50 11.21 t 0.45 Pass DW-80161,80162 8/22/2017 Ra-226 1.22 :t0.15 1.19:t0.17 1.21 :t0.11 Pass DW-80161,80162 8/22/2017 Ra-228 1.99 :t 0.63 0.70 t 0.49 1.35 :t0.40 Pass VE-4398,4399 8/28/2017 Be-7 0.13 t 0.07 0.13 :t 0.08 0.13 :t 0.05 Pass A5-3

1 3 1 TABLE A-5. In-House "Duplicate" Samples Concenlralion

  • Averaged Lab Code Date Analysis First Result Second Result Result Acceptance VE-4398,4399 8/28/2017 K-40 3.32 :t 0.22 3.48 :t 0.25 3.40 :t 0.17 Pass SW-4463,4464 812912017 H-3 495 :t 106 491 :t 106 493 :t 75 Pass l W-4486,4487 8/31/2017 Gr. Beta 0.425 +/- 0.471 1.358 :t 0.571 0.892 :t 0.370 Pass VE-4561,4562 9/6/2017 Be-7 5.89 :I: 0.29 5.76 :t 0.25 5.83 ::t 0.19 Pass VE-4561,4562 9/6/2017 K-40 3.73 :t 0.34 3.77 :t 0.29 3.75 ::t 0.22 Pass B0-5122,5123 9/8/2017 K-40 4.50 :t 0.36 4.50 :t 0.36 4.50 ::t 0.25 Pass VE-4692,4693 9/12/2017 K-40 5.16 +/-0.13 5.31 +/- 0.36 5.24 :t 0.19 Pass SS-4650,4651 9/12/2017 K-40 10.55 :t 0.51 10.41 :t 0.54 10.48 +/-0.37 Pass Ml-4671,4672 9/1312017 K-40 1,347 :t 115 1,283 :t 118 1,315 t 82 Pass Ml-4671,4672 9/13/2017 Sr-90 0.7 +/- 0.3 0.5 ::t 0.3 0.6 :I: 0.2 Pass VE-4973,4974 9/17/2017 K-40 1.11 ::t 0.15 1.17 :t 0.13 1.14 :t 0.10 Pass F-4928,4929 9/19/2017 K-40 1.84 :t 0.31 1.68 :t 0.34 1.76 :t 0.23 Pass S-4865,4866 9/20/2017 K-40 21.07 :t 2.39 19.09 :t 2.51 20.08 :1: 1.73 Pass VE-4907,4908 9/20/2017 K-40 3.83 +/- 0.44 4.28 :t 0.31 4.05 :1: 0.27 Pass VE-4844,4845 9/2112017 K-40 1.81 t 0.22 1.88 :t 0.21 1.84 +/-0.15 Pass AP-5572,5573 9/2712017 Ba-7 0.082 :t 0.015 0.075 ::t 0.014 0.078 :t 0.010 Pass LW-5145,5146 9128/2017 Gr. Beta 0.84 :t 0.49 1.47 :t 0.57 1.16 ::t 0.38 Pass AP-092917 9/29/2017 Gr. Beta 0.038 :I: 0.004 0.031 +/- 0.004 0.035 ::t 0.003 Pass WW-5080,5081 10/2/2017 H-3 208 :t 79 223 ::t80 215 :1: 56 Pass AP-100217 10/2/2017 Gr. Beta 0.025 t 0.005 0.028 ::t 0.005 0.026 t 0.003 Pass AP-100317 10/3/2017 Gr. Beta 0.037 :t 0.004 0.033 ::t 0.004 0.035 :t 0.003 Pass S-5165,5166 10/4/2017 K-40 15.93 t 2.30 20.34 :t 3.15 18.14 ::t 1.95 Pass VE-5228,5229 10/5/2017 K-40 3.25 t 0.25 2.82 :t 0.24 3.04 ::t 0.17 Pass AP-100917 10/9/2017 Gr. Beta 0.021 +/- 0.004 0.025 +/- 0.004 0.023 :t 0.003 Pass VE-5293,5294 10/10/2017 K-40 3.89 t 0.30 4.08 :t 0.34 3.99 :t 0.22 Pass DW-80184,80185 10/11/2017 Gr. Alpha 2.17 :t 0.81 2.50 :t 0.81 2.34 :t 0.57 Pass DW-80184,80185 10/11/2017 Gr. Beta 9.45 +/-0.79 10.20 :t 0.83 9.83 +/-0.57 Pass S-5421.5422 10/12/2017 K-40 8.82 +/- 1.94 7.97 :t 0.72 8.40 +/- 1.03 Pass AP-101617 10/16/2017 Gr. Beta 0.025 :1: 0.005 0.022 t 0.004 0.024 :t 0.003 Pass F-5658,5659 10/19/2017 K-40 2.44 :I: 0.41 2.57 :t 0.39 2.51 :t 0.28 Pass S0-5704,5705 10/25/2017 Cs-137 0.05 :t 0.02 0.04 ::t 0.02 0.04 :I: 0.01 Pass S0-5704,5705 10/25/2017 K-40 10.08 :t 0.51 9.57 ::t 0.56 9.83 t 0.38 Pass

$0-5704,5705 10/25/2017 TI-208 0.10 +/- 0.02 0.09 ::t 0.02 0.10 :t 0.01 Pass SO-5704,5705 10/25/2017 Bi-214 0.34 :t 0.04 0.27 :t 0.04 0.30 :t 0.03 Pass S0-5704,5705 10/25/2017 Pb-212 0.28 :t 0.03 0.27 :t 0.03 0.27 +/-0.02 Pass S0-5704,5705 10/25/2017 Ra-226 1.15 :t 0.52 0.59 t 0.22 0.87 :t 0.28 Pass S0-5704,5705 10/2512017 Ac-228 0.33 :t 0.05 0.31 :t 0.07 0.32 :t 0.04 Pass S0-5704,5705 10/25/2017 Gr. Beta 18.34 :1: 1.80 16.50 :t 1.03 17.42 :t 1.04 Pass AP-5732.5733 10/26/2017 Be-7 0.139 :t0.064 0.175 :t 0.075 0.157 +/- 0.049 Pass A5-4

1 3 2 TABLE A-5. In-House "Duplicate* Samples Concentration

  • Averaged Lab Code Date Analysis First Result Second Result Result Acceptance SW-5753,5754 10131/2017 H-3 220 +/- 83 279.t 86 249.t 60 Pass SWU-5816.5817 10/31/2017 Gr. Beta 1.51 :t 1.00 2.02.t 1.02 1.76.t 0.71 Pass AP-103117 10/31/2017 Gr. Beta 0.015 t 0.004 0.014 i: 0.004 0.015.t 0.003 Pass S0-5923,5924 11/1/2017 Cs-137 0.30 +/-0.04 0.31 :t 0.04 0.31 +/- 0.03 Pass S0-5923,5924 1111/2017 K-40 10.52 :t 0.61 10.56 t 0.67 10.54 +/- 0.45 Pass AP-5858,5859 11/2/2017 Be-7 0.145.t 0.075 0.146 :t 0.084 0.145 :t 0.056 Pass AP-110717 11nl2017 Be-7 0.026.t 0.004 0.030 :t 0.004 0.028 t 0.003 Pass WW-6032,6033 11/7/2017 H-3 204.t 86 298 :t 80 251.t 59 Pass WW..fi074,6075 11/8/2017 H-3 72,247 i: 786 73,062.t 791 72,655 i: 558 Pass 85-6053,6054 11/13/2017 K-40 7.99 t0.62 9.20.t 0.68 8.60 :t.0.46 Pass BS..0053,6054 11113/2017 Cs-137 0.07 :t 0.03 0.08 :t 0.03 0.07 :t 0.02 Pass DW-80211,80212 11/14/2017 Gr. Alpha 2.30 :t 0.80 3.60 t 1.00 2.95 :t 0.64 Pass DW-80211,80212 11/1412017 Gr. Beta 9.32 t 0.81 8.99 t0.81 9.16 :t 0.57 Pass DW-80214,80215 11/14/2017 Ra-226 1.36 +/-0.22 1.35 :t 0.15 1.355 :t0.13 Pass DW-80214.80215 11/14/2017 Ra-228 1.41 :t 0.51 0.90 :t 0.45 1.16 :t 0.34 Pass WW..fi152,6153 1111512017 H-3 416 +/- 94 328 :t 90 372 +/- 65 Pass SWU..fi219,6220 11/28/2017 Gr. Beta 1.04 :t 0.54 1.75 t0.58 1.39 :t 0.39 Pass SS..0242,6243 11/29/2017 K-40 24.17 :t 1.05 22.31 :t 1.03 23.24 :t 0.74 Pass SS..0242,6243 11/29/2017 Cs-137 0.11 :t 0.03 0.08 +/-0.03 0.10 :t 0.02 Pass SG-6938,6939 11/2812017 Pb-214 15.28 :t 0.34 14.96 :t 0.43 15.12 +/-0.27 Pass SG-6938,6939 11/28/2017 Ac-228 18.99 :t 0.59 19.92 :t 0.79 19.46 :t 0.49 Pass AP-112817 11/2812017 Gr. Beta 0.026 :t 0.004 0.030 :t 0.004 0.028 :t 0.003 Pass SQ-6286,6287 12/1/2017 Gr. Alpha 70.6 :t 6.2 60.9 +/- 6.0 65.8 +/-4.3 Pass S0-6286,6287 12/1/2017 Gr. Beta 48.9 :t 2.7 53.7 +/- 2.8 51.3 :t 1.9 Pass

$0-6286,6287 12/1/2017 Ra-226 11.3 :t 0.4 10.7 :t 0.5 11.0 :t 0.3 Pass S0-6286,6287 12/1/2017 Ra-228 13.5 :t 0.9 13.2 t 1.0 13.4 :t0.7 Pass SG..fi286,6287 12/1/2017 K-40 5.10 +/- 1.82 6.65 :t 1.53 5.88 :t 1.19 Pass AP-120417 12/4/2017 Gr. Beta 0.037.t 0.006 0.035.:t: 0.005 0.036.t 0.004 Pass WW..fi548.6549 12/19/2017 H-3 8,428 t 280 8,604 :t 282 8,516 t 199 Pass AP-122717 12/27/2017 Gr. Beta 0.047 t 0.004 0.043 +/- 0.004 0.045 :t 0.003 Pass XAP..fi762,6763 12/31/2017 CcxiO 2.43.t 1.30 2.24.:t: 0.82 2.34 +/- 0.77 Pass XAP-6762,6763 12/31/2017 Cs-137 4.21 t 1.11 4.05 t 0.96 4.14 t0.73 Pass Note: Duplicate analyses are performed on every twentieth sample received in-house. Results are not listed for those analyses with activities that measure below the LLD.

  • Results are reported In units of pCi/L. except for air fillers (pCi/Filter or pCi/m3), food products, vegetation, soil and sediment (pCi/g).

AS-5

1 3 3 TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP).

Concentration*

Reference Known Control Lab Code D Date Analysis laboratory result Activity Limits C Acceptance MAS0-903 2/1/2017 Am*241 60.9 :t 6.9 67.0 46.9 -87.1 Pass MAS0-903 2/1/2017 Cs-134 1360 :t 14 1550 1085

  • 2015 Pass MAS0-903 2/1/2017 Cs-137 678 :t 13 611 428
  • 794 Pass MAS0--903 2/1/2017 Co-57 1.63 :t 1.69 0.00 NAC
  • Pass MAS0-903 2/1/2017 Co-60 909 :t 12 891 624 -1158 Pass MAS0-903 2/1/2017 Mn-54 1052 :t 17 967 677
  • 1257 Pass MAS0-903 2/1/2017 K-40 657 :t 68 607 425
  • 789 Pass MAS0--903 2/1/2017 Zn-65

-0.52 :t 7.40 0.00 NAC Pass MASO-903 2/1/2017 Ni-63 3.25 t 7.17 0.00 NAC Pass MAS0-903 2/1/2017 Pu.238 0.46 :t 0.69 0.41 NA*

Pass MAS0-903 2/1/2017 Pu-239/240 56.8 :t 5.9 59.8 41.9

  • 77.7 Pass MAS0--903 2/1/2017 Sr-90 501 :t 17 624 437 -811 Pass MAS0.903 2/1/2017 To-99 748 :t 16 656 459 -853 Pass MAW-849 2/1/2017 1-129

-0.05 :t 0.12 0.00 NA C Pass MAVE-905 2/1/2017 C:;-134 6.61 :t 0.16 8.95 4.87

  • 9.04 Pass MAVE-905 2/1/2017 Cs-137 4.97 :t 0.18 4.60 3.22
  • 5.98 Pass MAVE-905 2/1/2017 Co-57

-0.01 :t 0.03 0.00 NA C Pass MAVE-905 2/1/2017 Co-60 9.51 :t 0.17 8.75 6.13 -11.38 Pass MAVE-905 2/1/2017 Mn-54 3.67 :t 0.17 3.28 2.30

  • 4.26 Pass MAVE-905 2/1/2017 Zn-65 6.12 :t 0.44 5.39 3.77
  • 7.01 Pass MAW-847 2/1/2017 Am-241 0.679 :t 0.079 0.846 0.592
  • 1.100 Pass MAW-847 2/1/2017 Cs-134 0.03 :t 0.10 0.00 NAC Pass MAW-647 2/1/2017 Cs-137 12.7 :t 0.4 11.1 7.8
  • 14.4 Pass MAW-647d 211/2017 Co-57 2.7 :t 0.3 28.5 20.0-37.1 Feil MAW-647 2/1/2017 Co-60 13.5 :t 0.3 12.3 8.6
  • 16.0 Pass MAW-847 211/2017 Mn-54 16.5 :t 0.4 14.9 10.4
  • 19.4 Pass MAW-647 2/1/2017 K-40 287 :t 6 254 178 - 330 Pass MAW-847 211/2017 Zn-65

-0.15 :t 0.23 0.00 NAC Pass MAW-847 211/2017 H-3 275 :t 10 249 174 - 324 Pass MAW-847 2/1/2017 Fe-55 2.4 :t 13.6 1.7 NA 8

Pass MAW-847 211/2017 Ni-63 10.1 :t 2.8 12.2 8.5

  • 15.9 Pass MAW-647 211/2017 Pu-238 0.729 :t 0.097 0.703 0.492
  • 0.914 Pass MAW-647 2/1/2017 Pu-239/240 0.866 :t 0.102 0.934 0.654 - 1.214 Pass MAW-847 211/2017 Ra-226 0.506 :t 0.053 0.504 0.353
  • 0.655 Pass MAW-847 211/2017 Sr-90 10.0 :t 0.8 10.1 7.1 -13.1 Pass A6-1

1 ~ 4 TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluatlon Program (MAPEP}.

Concentration

  • Reference Known Control Lab Code b Date Analysis laboratory result Activity Limits c Acceptance MAW-847 2/1/2017 Tc-99 4.77 t 0.62 6.25 4.38
  • 8.13 Pass MAW-847 2/1/2017 U-234/233 1.19 :t 0.10 1.16 0.81
  • 1.51 Pass MAW-847 2/112017 U-238 1.15 :t 0.10 1.20 0.84 -1.56 Pass MAAP-soi 2/1/2017 Am-241 0.0540 :t 0.0140 0.0376 0.0263 - 0.0489 Fail MAAP-907 2/1/2017 Cs-134 1.31 :t 0.06 1.42 0.99 - 1.85 Pass MAAP-907 2/1/2017 Cs-137 0.797 :t 0.080 0.685 0.480
  • 0.891 Pass MAAP-907 2/1/2017 Co-57 1.86 :t 0.06 1.70 1.19 -2.21 Pass MAAP-907 2/1/2017 Co-60 0.86 :t 0.05 0.78 0.55 - 1.01 Pass MAAP-907 2/112017 Mn-54 0.01 t 0.03 0.00 NAC Pass MAAP-907 2/1/2017 Zn-65 1.62 t 0.13 1.29 0.90
  • 1.68 Pass MAAP-907 2/1/2017 Pu-238 0.0530 :t 0.0190 0.0598 0.0419
  • 0.0777 Pass MAAP-907 2/1/2017 Pu-2391240 0.0490 +/- 0.0160 0.0460 0.0322
  • 0.0598 Pass MAAP-907 2/1/2017 Sr-90 0.648 :t 0.120 0.651 0.456
  • 0.846 Pass MAAP-907 2/1/2017 U-234/233 0.086 :t 0.024 0.104 0.073
  • 0.135 Pass MAAP-907 2/1/2017 U-238 0.097 :t 0.024 0.107 0.075
  • 0.139 Pass MAS0-4515 8/1/2017 Am-241 45.9 t 7.0 58.8 41.2
  • 76.4 Passa MAS0-4515 8/1/2017 Cs-134 409 :t 7 448 314
  • 562 Pass11 MAS0-4515 8/1/2017 Cs-137 798 :t 12 722 505
  • 939 Pass11 MAS0-4515 8/1/2017 Co-57 1572 :t 10 1456 1021
  • 1695 Passg MAS0-4515 8/1/2017 Co-60 0.2 t 1.4 0.00 NA C Pass11 MAS0-4515 8/1/2017 Mn-54 934 t 13 825 578
  • 1073 Passa MAS0-4515 8/1/2017 K-40 704 :t 53 592 414
  • 770 Pass11 MAS0-4515 8/1/2017 Zn-65 667 :t 17 559 391
  • 727 Pass11 MAS0-4515 8/1/2017 Pu-238 101 ::t 9 92 64
  • 120 Pass11 MASQ-4515 81112017 Pu-2391240 74.8 t 7.7 68.8 48.2
  • 89.4 Pass11 MAS0-4515 8/1/2017 Sr-90 252 t 7 289 202 - 376 Passg MAW4494 8/1/2017 1-129 2.31 :t 0.10 2.31 1.62
  • 3.00 Pass MAVE-4517 8/1/2017 Cs-134 2.40 :t0.10 2.32 1.62 - 3.02 Pass MAVE-4517 8/1/2017 Cs-137

-0.002 :t 0.048 0.000 NAC Pass MAVE-4517 8/1/2017 Co-57 3.3 t 0.1 2.6 2.0

  • 3.6 Pass MAVE-4517 8/1/2017 Co-60 2.10+/-0.10 2.07 1.45
  • 2.69 Pass MAVE-4517 8/112017 Mn-54 3.00 :t 0.20 2.62 1.83
  • 3.41 Pass MAVE-4517 8/112017 Zn-65 5.90 ::t 0.30 5.37 3.76 - 6.98 Pass A6-2

TABLE A-6. Department of Energy's Mixed Anatyte Performance Evaluation Program (MAPEP).

Concentration

  • Reference Known Control Lab Code b Date Analysis Laboratory result Activity Limits c Acceptance MAW-4513 811/2017 Am-241 0.820 :t 0.220 0.892 0.624 - 1.160 Pass MAW-4513 811/2017 Cs-134 10.3 :t 0.3 11.5 8.1 - 15.0 Pass MAW-4513 8/1/2017 Cs-137 17.2 :t 0.5 16.3 11.4
  • 21.2 Pass MAW-4513 611/2017 C<r57 12.7 :t 0.4 12.1 8.5
  • 15.7 Pass MAW-4513 8/1/2017 C<r60 10.6 :t 0.3 10.7 7.5
  • 13.9 Pass MAW-4513 8/112017 Mn-54 15.6 :t 0.4 14.9 10.4
  • 19.4 Pass MAW-4513 8/1/2017 Zn-65 15.9 :t 0.7 15.5 10.9
  • 20.2 Pass MAW-4513 8/1/2017 H-3 255 :t 9 258 181
  • 335 Pass MAW-4513 8/1/2017 Fe-55 21.6 :t 6.6 19.4 13.6
  • 25.2 Pass MAW-4513 8/1/2017 Nl-63

-0.1 :t: 2.0 0.0 NAC Pass MAW-4513 8/1/2017 Pu-238 0.590 :t 0.080 0.603 0.422 - 0. 784 Pass MAW-4513 8/1/2017 Pu-239/240 0.740 :t 0.090 0.781 0.547 - 1.015 Pass MAW-4513 8/1/2017 Ra-226 1.000 :t 0.100 0.858 0.601

  • 1.115 Pass MAW-4513 8/1/2017 Sr-90 7.80 :t 0.60 7.77 5.44 -10.10 Pass MAW-4513 8/1/2017 Tc-99 6.70 :t 0.40 6.73 4.71 - 8.75 Pass MAW-4513 8/1/2017 U-2344/233 0.94 :t 0.06 1.01 0.71 - 1.31 Pass MAW-4513 8/1/2017 U-238 0.97 :t 0.07 1.04 0.73 - 1.JS Pass MAAP-4519h 8/1/2017 Am-241 0.0400 :t:: 0.0100 0.0612 0.0428 - 0.0796 Fail MAAP-4519 8/1/2017 Cs-134 0.90 :t 0.10 1.00 0.70 - 1.30 Pass MAAP-4519 8/1/2017 Cs-137 0.90 :t 0.10 0.82 0.57 - 1.07 Pass MAAP-4519 8/1/2017 C<r57 0.01 :t 0.01 0.00 NA C Pass MAAP-4519 8/1/2017 C<r60 0.70 :t0.10 0.68 0.48 -0.88 Pass MAAP-4519 8/1/2017 Mn-54 1.50 :t:: 0.10 1.30 0.91 - 1.69 Pass MAAP-4519 8/1/2017 Zn-65 1.30 :t 0.10 1.08 0.76
  • 1.40 Pass MAAP-4519 8/1/2017 Pu-238 0.0300 :t 0.0100 0.0298 0.0209
  • 0.0387 Pass MAAP-4519 8/1/2017 Pu-239/240 0.0400 :t: 0.0200 0.0468 0.0328
  • 0.0608 Pass MAAP-4519 8/1/2017 Sr-90 0.800 :t 0.100 0.801 0.561
  • 1.041 Pass MAAP-4519 8/1/2017 U-234/233 0.070 :t 0.010 0.084 0.059
  • 0.109 Pass MAAP-4519 8/1/2017 U-238 0.090 :t 0.010 0.087 0.061 -0.113 Pass
  • Results are reported In units of BQ/kg (soil). Bq/L (water) or Bq/lotal sample (filters, vegetation).

0 Laborato,y codes as follows: MAW (water), MAAP (air filter), MASO (soil), MAVE (vegetation).

  • MAPEP results are presented as the known values end expected laboratory precision (1 sigma, 1 determination) end control limits as defined by the MAPEP. A known value of *zero* indicates an analysis was included in the testing series es a "false po8itiva*. MAPEP does not provide control limits.

11 Decimal point was misplaced while perfonning a unit conversion. The result is within control limlts v.tien the proper unit conversion is performed.

  • Provided in the series ror *sensitivity evaluation". MAf'EP does not provide control limits.

1 Sample was reanalyzed in duplicate wilh acceptable results. Original plating was inferior to platings obtained during reanalysis.

It is believed that isotopic tracer was not accurately quantified due to poor resolution of Its peak.

0 Data were erroneously submitted in units of Bq/g. All results pass MAPEP criteria when evaluated In units ol Bq/l(g.

h Laboratory Is not currently offering analysis for Am-241 in Air Particulate samples.

A6-3 1 3 5

1 ~ S TABLE A-7. lnter1aboralory Comparison Crosscheck Program, Envlronmental Resource Associates (ERA)*.

MRADSludl t,;oncentrallon

  • Lab Code b Date Analysis Laboratory ERA Control Result Result Limits*

Acceptance ERAP-1112 3/2012017 Am-241 55.3 +/- 2.8 76.4 47.1-103.0 Pass ERAP-1112 3/2012017 Co-60 1,230 :t 8 1030 797

  • 1290 Pass ERAP-1112 3/20/2017 Cs-134 1,110 :t 9 1100 700 -1360 Pass ERAP-1112 3/20/2017 Cs-137 1,810 +/- 12 1,390 1,040 - 1,830 Pass ERAP-1112" 3/20/2017 Fe-55 590 :t 385 256 79.4
  • 500 Fail ERAP-1112 3/2012017 Mn-54

< 5.14

< 50.0 0.00 - 50.0 Pass ERAP-1112 3/2012017 Pu-238 54.6 :t 2.8 54.3 37.2. 71.4 Pass ERAP-1112 3/20/2017 Pu-239/240 63.6 :t 3.0 62.0 44.9

  • 81.0 Pass ERAP-1112 3/20/2017 Sr-90 55.3 :t 8.3 52.4 25.6 - 78.5 Pass ERAP-1112 3/20/2017 U-233/234 65.7 :t 3.0 73.1 45.3 - 110 Pass ERAP-1112 3/2012017 U-238 67.3 t 3.0 72.4 46.8 - 100 Pass ERAP-1112 3/2012017 Zn-65 1,355 :t 16 984 705 - 1,360 Pass ERAP-1114 3/20/2017 Gr. Alpha 106 :t 5 85.5 28.6 -133 Pass ERAP-1114
  • 3/20/2017 Gr. Beta 67.6 +/- 3.0 45.2 28.6 -65.9 Fail ERS0-1116 3/2012017 Am-241 418 :t 98 448 262
  • 582 Pass ERS0-1116 3/20/2017 Ac-228 1,540 :t 260 1,240 795 -1,720 Pass ERS0-1116 3120/2017 Bi-?.12 1,550 :t 90 1,240 330 -1.820 Pass ERS0-1116 3/20/2017 Bi-214 2,560 :t 20 2,750 1,660
  • 3,960 Pass ERS0-1116 3120/2017 Co-60 4,620 t 100 4,430 3,000
  • 6,100 Pass ERS0-1116 3120/2017 Cs-134 8,340 :t 100 8,860 5,790 - 10,600 Pass ERS0-1116 3120/2017 Cs-137 8,420 :t 100 7,500 5,750
  • 9,650 Pass ERS0-1116 3120/2017 K-40 13,600 :t 900 10,600 7,740
  • 14,200 Pass ERS0-1116 3/20/2017 Mn-54

< 68.1

< 1000 0.00 -1,000 Pass ERS0-1116 3/20/2017 Pb-212 1,060 :t 70 1,240 812 - 1,730 Pass ERS0-1116 3120/2017 Pb-214 2,620 +/- 160 2,890 1,690

  • 4,310 Pass ERS0-1116 3/20/2017 Pu-238 424 :t 154 648 390
  • 894 Pass ERS0-1116 1 3/20/2017 Pu-239/240 252:t:112 484 316 - 669 Fail ERS0-1116 8 3120/2017 Pu-239/240 436.:t 106 484 316
  • 669 Pass ERS0-1116 3/20/2017 Sr-90 7,930 :t 250 9,150 3,490
  • 14,500 Pass ERS0-1116 3/20/2017 Th-234 1,820.:t 200 1,940 614 - 3,650 Pass ERS0-1116 h 3120/2017 U-233/234 1,030 :t 130 1,950 1,190
  • 2,500 Fall ERS0-1116 1 3/20/2017 U-2331234 1,820 :1: 200 1,950 1,190
  • 2,500 Pass ERS0-1116 3/20/2017 U-238 1,240.:t 140 1,940 1,200
  • 2.460 Pass ERS0-1116 1 3/20/2017 U-238 1,930 :t 200 1,940 1,200
  • 2,460 Pass ERS0-1116 3/20/2017 Zn-65 7,190.:t 240 6,090 4,850 - 8,090
  • pass ERW-1122 3/20/2017 Gr. Alpha 65.3 :t 2.4 89.5 31.8-139 Pass ERW-1122 3/20/2017 Gr. Beta 54.8+/-1.5 61.0 34.9 - 90.4 Pass ERW-1124 3/20/2017 H-3 19,000 +/- 410 19,400 13,000
  • 27,700 Pass A7-1

TABLEA-7. lnterfaboratory Comparison Crosscheck Program, Environmental Resource Associates (ERA)9.

MRADStudl COncentratlon ° Lab COde b Date Analysis Laboratory ERA Control Result Result Limits c Acceetance ERVE-1118 3/20/2017 Am-241 1,560 :t 140 1,860 1,140

  • 2.470 Pass ERVE-1118 3/20/2017 Cm-244 530 t 80 734 360
  • 1,140 Pass ERVE-1118 3/20/2017 Co-60 1,400 :t 350 1,390 959
  • 1,940 Pass ERVE-1118 3/2012017 Cs-134 1,650 t 460 1,830 1,180 - 2,380 Pass ERVE-1118 3/20/2017 Cs-137 2,580 :t 540 2,500 1,810
  • 3,480 Pass ERVE-1118 3/20/2017 K-40 32,100 :t 700 30,900 22,300 - 43,400 Pass ERVE-1118 3/20/2017 Mn-54

<27.3

< 300 0.00 - 300 Pass ERVE-1118 3/20/2017 Zn-65 889 :t 64 853 615-1.200 Pass ERVE-1118 3/20/2017 Pu-238 3,250 :t 210 3,250 1,940 - 4,450 Pass ERVE-1118 3/20/2017 Pu-239/240 2,180 :t 170 2,150 1,320 - 2,960 Pass ERVE-1118 3/2012017 Sr-90 665 :t 135 726 414 - 963 Pass ERVE-1118 3/20/2017 U-233/234 2,840 :t 200 3,090 2,030 - 3,970 Pass ERVE-1118 3/20/2017 U-238 2,990 :t 200 3,060 2,040

  • 3,890 Pass ERW-1120 3/20/2017 Am-241 108 :t 7 140 94.3 - 188 Pass ERW-1120 3/20/2017 Co-60 2,600.t 198 2,540 2,210 - 2,970 Pass ERW-1120 3/20/2017 Cs-134 2,380 t 250 2,510 1,840
  • 2880 Pass ERW-1120 3/20/2017 Cs-137 1,470 :t 243 1.400 1,190 -1,680 Pass ERW-1120 3/20/2017 Mn-54

< 12.3

< 100 0.00 -100 Pass ERW-1120 3/20/2017 Pu-238 117:1:4 128 94.7-159 Pass ERW-1120 3120/2017 Pu-239/240 74.8 :t 3.3 85.8 66.6

  • 108 Pass ERW-1120 3/20/2017 U-233/234 75.3 :t 3.2 90.3 67.8 - 116 Pass ERW-1120 3/20/2017 U-238 76.4.t 3.2 89.5 68.2 -110 Pass ERW-1120 3/20/2017 Zn-65 2,130 :t 378 1,960 1630 - 2,470 Pass ERW-1120 1 3/20/2017 Fe-55 1.400 :t 403 984 587 - 1,340 Fail ERW-1120 ~

3/20/2017 Fe-55 1,081 :1: 383 984 587 - 1,340 Pass ERW-1120 3/20/2017 Sr-90 652 :t 12 714 465

  • 944 Pass
  • Results obtained bv Environmental, Inc., Mitfwest Laboratory as a participant in the aosscheck prt>Rram f<lf crofidencv testing administered by Environmental Resources A.<t.'lnciatas, serving es e replacement for studies conducted previously by the Environmental Measurements laboratory Qua61y Assessment Program (EML).

~ Laboratory codes es follows: ERW (waler). ERAP (air filter). ERSO Csolll. ERVE (vepetationl. Results are reoorted in units of p(A/1.. except for air fillers (pCi/Filter). vegetation and soil (pCl/kg).

e Results ere presented es the known values. el(p8Cted laboratory precision (2 siQma, 1 determination) and control limits as provided by ERA.

° Fe-55 anatvsls result was outside the accectable ranQe. Recountinq the Bample disk for 1000 minutes resulted in 254 :I: 364 with en LLD calculation of< 342. Insufficient sample was available after perfonning other required analyses on the sample to quantify lhe activity with an uncertainty less than the activity.

  • ERA BPOeSrs to have acolied the standard material to the filler in a oattem closer to the center of the Jilter com cared lo orevious studies and different from the filler efficiency utilized by the laboratory. This likely caused the efficency used the calculation to be undeistated and the result obtained by the laboratory lo be overstated. For comparison the in-house spike to, gross beta in AP (table A*3 SPAP-740 2/28117) was acceptable with a ratio of 0.94 of lab result to known.

' Analysis result for Plutonium-239/240 was below the lower limit of acceptance.

11 Samples were reanalyzed in duplicate with acceotable results for each. OriQinal anatvsis had P00f resolution POSSlblv due to a poor elctroplating and is suspected in contributing to poor resu Its.

" Analysis result for U-233/234 was below the lower limit of acceptance.

1 The reanatvsis result for U-2331234 was within the acceptance limits and U-238 reanatvsis result was doser to the known value.

Original analysis had poor resolution possibly due to a poor electroplating and is suspected in contributing to poor results.

1 Fe-55 analysis result was outside acceptable ral'l{le.

k Resutl of recountinA was acceptable. UsinA available aliauot after dM1linq samote fo, other anarvses leaves insufficient sample to reliably determine the activity present In sample.

A7-2 1 3 7

1 3 8 APPENDIX B DATA REPORTING CONVENTIONS B 1

Date Reporting Conventions 1.0. All activities, except gross alpha and gross beta, ere decay corrected to collection time or the end of the collection period.

2.0. Single Mea1;urements Each single measurement is reported as follows:

x :t: s where:

x c: value of the measurement; s "' 2a counting uncertainty (corresponding to the 96% confldence level).

In cases where the activity is less than the tower limit of detectlon L, ii Is reported as: < L, where L.. the lower limit of detectlon based on 4,66o uncertainty fer a background sample.

3.0. Oupljcate analyses If duplicate analyses are repcrted, the convention is a11 follows. :

3.1 lndjyjdual renulls: For two analysis result!i; x1 :t s1 and X:i :t s2 Reported result:

x +/- s: where

?<- = (1/2) (x, +><:)ands"' (112).Js1 2 + s; 3.2.

3.3.

Individual rP,su11g: cl

- 1

  • l.[ldivldual,~ x +/- s, < L 4.0. Computation of Averages and S:andard Qevlatls2!m Repor1ed_~sult; < 1-, where L = lower of L1 and L, Reported rasull; x :t s if x ~ L; < L otherwise.

4.1 Averages and standard deviations hsted In the tables are computed from all of the individual measurements over the period averaged; for exa~ple, an annual standiud devla<<ol"! would not be the average of quarterly standard deviations. Th~ average x and stiindard deviation *s* of a set of n numbers x,, ~... x" are defined as follows:

1 X "'n LX

-~

8"' -\\J-;;:r 4.2 Values below the highest lower limit of detectlon ere not fnduded in the average.

4.3 If all values in the averaging group are Jess than the highest LLD. the highest LLD is reported.

4.4 If all but one of the val1.1ea are 18S$ than the highest I.LO, the single \\'aluo x and associated two sigma error is reported.

4.5 In rounding off, the fotlowing nJles a~ followed:

4.5.1, If the number followlny tho~e to be r1:,\\ainsd If) leei. than 5, the number Is dropped, and the retained numbers are kept vnchanged. As an Axample. 11.443 ls rounded off to 11.44.

4.5.2. If the number following those to be re~ined is equ~I to or greater than 5, the number is dropped and the last retained number is raised by 1. As an example, 11.445 is rounded off to 11.45.

B-2 1 :1 9