L-05-030, Sixteenth Refueling Outage Inservice Inspection Report

From kanterella
Jump to navigation Jump to search
Sixteenth Refueling Outage Inservice Inspection Report
ML050470247
Person / Time
Site: Beaver Valley
Issue date: 02/10/2005
From: Pearce L
FirstEnergy Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-05-030
Download: ML050470247 (152)


Text

FENOC Beaver Valley Power Station RO. Box 4 FirstEnergy Nuclear Operating Company Shippingport, PA 15077-0004 L. William Pearce 724-682-5234 Vice President Fax: 724-643-8069 February 10, 2005 L-05-030 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001

Subject:

Beaver Valley Power Station, Unit No. 1 Docket No. 50-334, License No. DPR-66 Sixteenth Refueling Outage Inservice Inspection Report This letter forwards the Inservice Inspection (ISI) Ninety-Day report on ASME Class 1, 2, and 3 components examined during the sixteenth refueling outage (IR16) at Beaver Valley Power Station (BVPS) Unit 1. The ASME Boiler and Pressure Vessel Code, Section Xl, Article IWA-6230 requires that an inservice inspection report be submitted to the enforcement and regulatory authority having jurisdiction at the plant site within ninety days after completion of an inservice inspection. The recent inservice inspection term at BVPS Unit 1 ended on November 13, 2004.

The Class 1, 2 and 3 examinations are part of Interval 3, Period 2 of the Unit 1 IS1 schedule, and were performed in accordance with Section XI of the ASME Boiler and Pressure Vessel Code, 1989 Edition.

There are no new regulatory commitments identified in this document. If you have any questions concerning this matter, please contact Mr. Larry R. Freeland, Manager, Regulatory Compliance at 724-682-4284.

Sincerely, C L. W. Pearce Attachment c: Mr. T. G. Colburn, Project Manager Mr. P. C. Cataldo, Sr. Resident Inspector Mr. S. J. Collins, NRC Region I Administrator Mr. J. Payton, Commonwealth of Pennsylvania

BEAVER VALLEY POWER STATION UNIT I Route 168, Shippingport, PA Outage 16, Year 2004 Inspection Term: 4/27/2003 to I11/13/2004 Issue date: 2' -O5 Owner: FirstEnergy 76 South Main St.

Akron, OH 44308 NRC Docket Number: 50-334 Reactor Supplier: Westinghouse Electric Corporation Commercial Service Date: September'30, 1976 Prepared by: Date: '/2 4- s Reviewed b Date: I 0L OS ar Programs Reviewed by: Date: c~t. L.

ANII Approved by: rZVJ c} ASAC Dc& . 5 Date: _28_ C>

Manager, Technical Services Engineering I

90-DAY REPORT TABLE OF CONTENTS Item Page Number Cover Page 1 Table of Contents 2 Form NIS-I 3 -4 Outage Summary 5 ASME XI Vessel, Piping and Support Examinations 5

1. Class I 5
2. Class 2 5

Pressure Testing 5

Deficiency Resolution 5s 5

Steam Generator Tube Examination 5

NIS-2 Forms Appendix I - Completed Code Examinations Appendix 11- Repair/Replacement Abstract and NIS-2 Forms 2

FORM NIS-l OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. Owner FirstEnergy Nuclear Operating Company, Route 168, Shippingport, PA 15077 (Name and Address of Owner)
2. Plant Beaver Valley Power Station, Route 168,'Shippingport, PA 15077 (Name and Address of Plant)
3. Plant Unit 1 4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date 9130/76 6. National Board Number for Unit N/A
7. Components Inspected ^  : -

Manufacturer or; Component or Manufacturer or Installer State or National Appurtenance Installer Serial No. Province No. Board No.

Reactor Vessel Combustion Engineering 69103 105642B 21011 Pressurizer Westinghouse 1311 434676V 68-50 IA Steam Generator Westinghouse :1301 434597V 68-45 I B Steam Generator Westinghouse 1302 434598V 68-46 IC Steam Generator Westinghouse 1303 434599V 68-47 Reactor Coolant Piping Southwest Fabricating N/A N/A N/A Auxiliary Piping Schneider Power N/A N/A N/A Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1 in. x II in.

(2) information in items I though 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (E0029) imy be obtained from the ASM E Order Dept., 22 Law Drive. Box 2300. Fairfield, NJU 07008.-2300 3:

FORM NIS-1 (Back)

8. Examination Dates 4127/2003 to 11/13/2004
9. Inspection Period Identification: 8/112001 to I2/22004
10. Inspection Interval Identification: 9/21/1997 to 3/31/2008
11. Applicable Edition of Section XI 1989 Addenda None
12. Date/Revision of Inspection Plan: 1/2-ADM-2039, Revision I
13. Abstract of Examination and Tests. Include a list of examinations and tests and a statement concerning status ofwork required for the Inspection Plan. See Appendix I (Code Exams) for exams performed during IR16. IR16 was the third outage in the 2" Period of the 3rd Ten-Year IntervaL Whis was the last outage In this period.. All examinations hive been competed to fulfill the 2"d Period completion percentage requirements specified by ASME XL
14. Abstract of Results of Examination and Tcsts. See text of summary report.
15. Abstract of Corrective Measures. No Corrective measures resulting from NDE [SI examinations were required in IR16 We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section Xl.

Certificate of Authorization No. (if applicable) N/A Expiration Date N/A Date I I zelos Signed FirstEnergy Nuclear Operating Co. By > g a _

(Owner) G CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid cormrnission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by Hartford Steam Boiler. of Connecticut have inspected the components described in this Owner's Report during the period V-.L7- 03 to //-/3 -0 9/ and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer make any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in anyimanner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection

_ Commissions /i%

, AxZ /,4 a

[nspcc!tignaturc National Board, State, Province and Endorsements Date __/_ _ _ _ _

4

t i;z OUTAGE

SUMMARY

During the Sixteenth Refueling Outage (1R16) at the Beaver Valley Power Station, Unit 1, Inservice Inspection (ISI) examinations were performed on Class 1 and 2 components. This was the third outage in the second period of the third ten year interval. The examinations were based on ASME Section XI, 1989 Edition.

ASME XI Class I and 2 Credited Exams (See Appendix I)

1. Four (4) Class I exams were performed:

Vessels, Visual Exams - 4

2. Thirteen (13) Class 2 exams were performed:

Piping Welds, Ultrasonic Exams - 13

3. Thirty-six (36) Class I and 2 RI-ISI VT-2 exams were performed:

Piping Welds, Visual Exam (VT-2) - 36 Examinations were performed by FirstEnergy Nuclear Operating Company (FENOC) NDE Technicians.

Appendix I compiles the examinations that have been credited toward fulfilling the Ten Year Plan requirements.

Pressure Testing The Class 1 piping System Leakage Test was performed prior to plant start-up from I R16. All Class I bolted connections were examined during IR16. Also, Class 2 and 3 system functional and system inservice tests were performed in accordance with 40-month pressure testing requirements.

Deficiency Resolution There were no recorded ISI NDE deficiencies in 1R16.

Steam Generator Tube Examination One hundred percent of the in-service tubes were examined in the three generators. Results of the examinations are submitted to regulatory authorities per Technical Specification requirements.

NIS-2 Forms Included as Appendix IIare the NIS-2 Forms associated with repairs and replacements. Code Case N-416-1 or N-416-2, Alternative Pressure Test Requirement for Welded Repairs or Installation of Replacement Items by Welding, Class 1, 2 and 3, was used. The NIS-2 specifies when the Case was implemented and which revision was used.

5

APPENDIX I COMPLETED CODE EXAMINATIONS

.1 APPENDIX I 1R16 Completed Code Exams

SUMMARY

COMPONENT ID CLASS CATEGORY ITEM NO DESCRIPTION NDE METHOD ISONO 193100 RC-TK-1-RADIUS-6 I B-D B03.120 NOZZLE INSIDE RADIUS VT-2, E-001P 186100 RC-E-IB-RADIUS(2H) I B-D B03.140 NOZZLE INSIDE RADIUS VT-1, E-001M 186200 RC-E-1 B-RADIUS(2C) 1 B-D B03.140 NOZZLE INSIDE RADIUS VT-1 , E-001M 162000 RC-R.1-ACC-INT I B-N-1 B13.010 INTERIOR VT-3, E-001F 598900 SI-1 S-02 2 R-A R01.011 PIPE WELD UT, 0083B 605400 SI-1-4D-S-04 2 R-A R01.011 PIPE WELD UT, 0083C 598850 SI-1-6-L-40 2 R-A R01.01I LONG WELD UT, 0083B 598950 SI-1-6-L-39 2 R-A R01.011 LONG WELD UT, 0083B 605320. SI-1 -4D-L-01 2 R.A R01.01I LONG WELD UT, 0083C 605350 SI-1-4D-L.02 2 R-A R01.01I LONG WELD UT, 0083C 605420 SI-1 D-L-03 2 R-A R01.011 LONG WELD UT, 0083C 757450 RS-25-3N-L-131 2 R-A R01.011 LONG WELD UT, 0079B 757500 RS-25-3N-S-04 2 R-A R01.011 PIPE WELD UT, 0079B 757550 RS-25-3N-L-1 30 2 R-A R01.011 LONG WELD UT, 0079B 768450 RS-1 1-2-L-208 2 R-A R01.01I LONG WELD UT, 0081A 768500 RS-11-2.S-03 2 R-A R01.01I PIPE WELD UT, 0081A 768550 RS-1 I-2-L-207 2 R-A R01.011 LONG WELD UT, 0081A 033300 CH-96-9-F-1 3 1 R-A R01.012 SOCKET WELD VT-2, 0246A 036700 CH.97-7-S-07 I R-A R01.012 SOCKET WELD VT-2, 0247A 040000 CH-98-9-S-06 I R-A R01.012 SOCKET WELD VT-2, 0248A 298000 SI-102-2A-F-1A I R-A R01.012 SOCKET WELD VT-2, 0200A 300300 SI-106-1 C-S-02 I R-A R01.012 SOCKET WELD VT-2, 0200B 332300 Sf-104-1 -F-02 I R-A R01.012 SOCKET WELD VT-2, 0376A 436000 CH-69-1-S-07 2 R-A R01.012 PIPE WELD VT-2, 0267A 443800 CH-71-1-S-07 2 R-A R01.012 PIPE WELD VT-2, 0267A 397700 SI-82-1-S-01 2 R-A R01.012 SOCKET WELD VT-2, 0192A 420100 CH-79-2B-S-07 2 R-A R01.012 SOCKET WELD VT-2, 0265A 422700 CH-78-2B-S-06 2 R-A R01.012 SOCKET WELD VT-2, 0265A 425200 CH-77-2B-S-05 2 R-A R01.012 SOCKET WELD VT-2, 0265A 440000 CH-70-1 F-IX-A 2 R-A R01.012 SOCKET WELD VT-2, 0267A 078600 RC-71-9-S-06 1 R-A R01.012 BRANCH CONN. WELD VT-2, 0348B 085400 RC-72-4E-S-06 I R-A R01.012 BRANCH CONN. WELD VT-2, 0348D 420200 CH-79-2B-S-10 2 R-A R01.012 BRANCH CONN. WELD VT-2, 0265A 422600 CH-78-2B-S-10 2 R-A R01.012 BRANCH CONN. WELD VT-2, 0265A 425000 CH-77-21B-S-10 2 R-A R01.012 BRANCH CONN. WELD VT-2, 0265A 470350 CH-131-1-F-4X 2 R-A R01.012 SOCKET WELD VT-2, 0268A 509200 CH-1 24-1 0-F-09B 2 R-A R01.012 BRANCH CONN. WELD VT-2, 0273A Page Al-I

rT wn o) o) o) o o) uw o C) IRT w 0 az tD MV0 V)

C0 C) <o) M a M a O O) V- NN uD W W a aC) a U) 1 0 0 0N 0N 0N 0 N N 0 N C N N 0a Ul0 ww z-j Z:Z -j O D wwu-10wwwwwww U)

E Z0 0w Z Yj Y Q~Ne ! Z z cY Y O -MX 1- e x eaooo w m 00ww m ) en 3 a) ;kz o 0009<<00 00000

-a- 00 £00 00000 m ~fc n )U V) V) V) o) ) )Cc w U) U) C) N Ct Z(0 a) cL R 0 cm ES0 N N N N N JN N N CN N CL QL V-- T-- V- ¶- - v- - 't- 'e-a-

< E oO ) 0 9> O0. VY- t- O. O0.0O.

0 w cr -w WI_ 0 0Olc a O. CD 0 C> 0 0 N0 0 oVa:0 TZ 1-w w w - 1> a:-wwiC> C co aw N .fi . . . N N N N. . .N N N N f

No- N4 - cN co

'- 0)

U).,-

  • cn (1) S T

a o,

'- i- T

't -'r o tD (D1<tCD CO q °)- 0)0t) sO.t-

  • S
  • I I I 0)0 0 U) 0 0 0 0 0D a ONC 0 U) (0 0 0 0 I'- 0 U) 0 a o0 f- cq co x wo co tw w N U)00303 N U) (0 rs o) 10 ) 0 co w t- am m Cr) lv w D m om a 0- c0m,CD c 0 o0 3 IITDUt- -CDC > '_- _ N.N N
  • o 0)) D )CD )

APPENDIX II REPAIR / REPLACEMENT ABSTRACT AND NIS-2 FORMS

. ;* 4..

t NIS-2 ABSTRACT FORM NO. MARK NUMBER WORK ORDER NO. COMMENTS 1556 RV-1 QS-100B 200029417 Corrected 1588 WR-651 02-010713-000 Replacement 1589 WR-42 02-010714-000 Replacement 1RW-141 1590 1VS-E-4B 02-014057-000 Replacement 1622 RV-1 CH-203 200024659 Corrected 1642 TV-1 IA-400 02-008296-002 Installed a

I IA-90-4 Installed I IA-90-1 Installed lIA-90 Replacement ACC-34 Replacement ACC-35 Replacement ACC-113 Replacement 1686 I PC-108 200022048 Corrected 1689 MOV-1 RC-535 200045735 Installed 1690 WR-649 200043580 Installed WR41 Installed 1RW-140 Removed 1697 IRS-E-1A 200072000 Corrected 1698 I RS-E-1 C 200071998 Corrected 200066742 1699 FE-IFW-101A 200015625 Installed 1700 FE-1 CH-1 30 200091968 Corrected 1707 1CH-175 200102418 Installed 1708 1CH-177 200102056 Installed 1709 IMS-19 200070073 Installed 1710 1MS-20 200070072 Installed 1711 NRV-1MS101C 200015445 Corrected 1712 SV-1 MS-101 C 200017570 Installed 1713 SV-1 MS-102C 200017597 Installed 1714 SV-1 MS-103C 200017417 Installed 1715 SV-1 MS-104C 200016390 Installed 1716 SV-1 MS-105C 200016415 Installed 1722 REJ-1 RW-25A 200074185 Installed 1723 REJ-1 RW-25B 200014525 Installed 1724 REJ-I RW-27A 200074189 Installed 1725 IMS-18 200070163 Installed 1726 I MS-80 200065000 Corrected 1727 IMS-81 200065001 Corrected 1728 1IMS-82 200065002 Corrected 1735 HYV-1 FW-100A 200015627 Installed 1736 HYV- FW-100B 200015586 Installed 1737 HYV-1 FW- 00C 200015457 Installed 1740 RV-1 RC-551A 200059462 Installed 1741 ICH-138 200027095 Corrected 1743 1RW-811 200013659 Corrected 1744 REJ-M RW-4A1 200074190 Installed 1745 IMS464 200073988 Corrected Page 1 of 2

x . %

NIS-2 ABSTRACT FORM NO. MARK NUMBER WORK ORDER NO. COMMENTS 1746 I FW-156A 200069902 Corrected 200073924 1747 1FW-156B 200069903 Corrected 200073925 1748 I FW-156C 200069887 Corrected 200073926 1751 MOV-1 RW-113A 200015380 Installed 1752 MOV-1 RW-113B 200015411 Installed 1753 MOV-1 RW-113C 200015338 Installed 1754 MOV-1RW-113D1 200017496 Installed 1756 I RW-106 200072006 Corrected 1757 WR-14 200120728 Corrected 1759 FE-IFW-101B 200015446 Installed 1760 FE-I FW-101 C 200015455 Installed 1761 IRC-E-IA 200062494 Corrected .

1762 I RC-E-1 B 200062495 Corrected 1763 IRC-E-IC 200062499 Corrected 1772 CC-HSS-021 B 200066371 Replacement 1773 RC-PSSP-129 200066374 Replacement 1774 WGCB-PSSP-200A 200066377 Replacement WGCB-PSSP-55E 1775 WFPD-HSS-229 200066386 Replacement 1776 SHP-HSS-206 200066387 Replacement SHP-HSS-211 1777 RH-HSS-203 200066389 Replacement 1778 CC-HSS-408 200066390 Replacement RH-HSS-1 14 1779 RS-HSS-209A 200066391 Replacement SI-PSSP-01 0 S WR-HSS-308 Page 2 of 2

I FORM WADM-O80L:02 REV I RTL # A4.414-A Form No. 1556

  • FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi
1. Owner First Energy Date 10/22/ 2003 (NAME) 76 South Main Street - Akron. OH 44308 Sheet 1 of 1 (ADORESS)
2. Plant Reaver'Vallov Powor Statior I

_ __ . _ . .= ... _ . .. . _ . . _ . _ ._ ...... _ .

Unit No. 1 (NAME)

Shippincwort, PA 15077 Order #200029417 (ADORESS) RepaidfReplacenwit Orgarizabor i P.O. No.. Job No_ etO

3. Work Performed By FENOC-Maintenance Typb Code Symbol Stamp
  • N/A (NAME)

Shinninanmrt PA 15077 Authorization No. N/A (ADDRESS)

, - Expiration Date

4. Identification of System Quench Spray (Q3)
5. (a) Applicable Construction Code Section VIII- 19 77 Edition, W79 Addenda. N/A Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989 (c) Applicable Section Xl Code Case(s): NIA  :
6. Identification of Components Corrected. ASME.

Reniond. code Nam of NKa of Mamractv= Natioal Board Other Yew or I S e Cmfoow Nfaw r a SergeML NoO , drcnirlmioon Baillz intale (Yes or No)

SaftylRelief Dresser TEl97872 - IN/A RV-IQS-IOOB _ Corrected Yes Valve Disc Dresser ADB45 N/A N/A 2003 Installed No Nozzle Dresser ADB94 NIA lit #714573 2003 Installed No

7. Description of Work Replaced valve disc and nozzle.
8. Tests Conducted: Hydrostatic [] Pneumatic 5 Nominal Operating Pressure E Exempt a Other [] Pressure psi Test Temp. _ _ F
  • 1 FORM WADM-080l.F02 REV I RTL #A4.414-A FORM NIS-2 (Back)
9. Remarks No Code Data Reports available. Previous NIS-2 Data Report No:743. *Year installed.

Applcabie MematWas Data Repots to be attadced CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date NIA Signed -'Swi L-'r. Date Lo/tZ. 20 03 Owner or Owners Oesigneo.

Title I CERTIFICATE OF INSERVICE INSPECTION

1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT. have inspected the components described in the Owner's Report during the period 3 -S;3 - <0 2 to /0_-7 - 3 ,andstatethattothe best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Did0Wf " 61 signawtue Commissions  ;,

Haul

'f war to* A 3) it State. Province. and Erdorsefents Date /O , 200 ° 3

FORM W-ADM-080 1.F02 REV 0 RTL # A4.414-A Form No. 1588 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI'

1. Owner F.E.N.O.C. Date 07/21/03 (NAME) . . ..

76 South Main Street - Akron, OH 44308 Sheet 1 of 1 (ADDRESS)

2. Plant R.Pnvpr VaIIpv Pnwnr.Rtation , Unit No. 1 (NAME) .

.IjII IUIJI r%5 E .YU I I uu n 4Hno-nin,7,t 3nnn rc-w IPut W I uI (ADDRESS) REPAIR ORGANIZATION P.O. NOW "OBNO, ErC.

3. Work Performed By FENOC-Maint. Services Type.Code Symbol Stamp N/A (NAME)

Shippinaport, PA 15077 - - Authorization No. N/A (ADORESS)

Expiration Date _

4. Identification of System River Water (Q3)
5. (a) Applicable ConstructionCode ANSI 831.1 19_f67 Edition. S71Addenda, N/ACode Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989*
6. Identification of Components Repaired or Replaced and Replacements Components Repaked ASME Rep.ced Code Nafferof NN of MawUfacrx" Naimal Bowd ber Yeaw or Stup4 d Con'oen l )damorc~m Sera No. * ' ~uhith

'NIO Rugbcwn YN5Sm Piping Stoie& NIA N/A WR-651 1976 Replace. No Webster - Ment

, . -~~~~~~.
7. Description of Work Replaced viie and fittings.
8. Tests Conducted: Hydrostatic E] Pneumatic El Nominal Operating Pressure 0 Other 0 Pressure psi Test Temp. OF

I '

FORM S-ADM-0801.F02 REV 0 RTL # A4.4 14-A FORM NIS-2 (Back)

9. Remarks No Code Data Reports available. Replacement in accordance with Code Case N416-1.

CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and thic conforms to the rules of the ASME Code Section Xl. Repair Or. Replacernt Type Code Symbol Stamp N/A .

Certificate of Authorization No. N/A Expiration Date NMA Signed /Ja1 ° E:

J4;- E,6:x. Date July 21 . 20 03 owner or OCer!s Desr ge rime CERTIFICATE OF INSERVICE INSPECTION

1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in the Owner's Report during the period S* 9
  • 0 3 to 7- AS= 03 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures descnbed in this Owner's Report in accordance with Ihe requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shalt be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions /G 5rjz r C/

CSignature Natonal Board, State. Province. ad Endorsenient Date _ __- _J_ , 20 0 3

FORM WADM-0801.F02 REV 0 IZTL # A4.414-A Form No. 1589 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

-As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C. Date 07/21/03 76 South Main Street - Akron. OH 44308 Sheet 1 of 1 (ADDRESS)
2. Plant Beaver Valley Power Station Unit No. 1 (NAM)

Shinninanort, PA 15077 W.O. #02-010714-000 (ADORESS) REPAIR ORGANtZATIOl PO. NO, JOB NO., ETc.

3. Work Performed By FENOC-Maint. Services Type\Code Symbol St~imp. NA (NAME)

Shipoincport. PA 15077 Authorization No. N/A (ADDRESS)

Expiration Date _

4. Identification of System River Water (03) 5.; (a) Applicable Construction Code ANSI B31.1 19 67 Edidion, S.71 Addenda, jN Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements, 1989
6. Identification of Components Repaired or Replaced and Replacements Components Rep.. ACDE Nor of Neit ofa nutr Nil Bod Odler Yew or Suv'ed.

C; qVwuf m.camtsm Saew No. No. ldawificmio Ba B - (YES or

. . .NO)

Piping Stone & N/A N/A WR42 1976 Replace- Nd Webster ': - ent

'Gate Valve Crane NIA N/A IRW-141 1976 Replaced No Ball Valve Controniatics 85-332-17-2 NIA IRW-141 2003 Replace- . No

.nent

7. Description of Work Replaced valve, pipe and fittings.
8. Tests Conducted: Hydrostatic [l Pneumatic 0 Nominal Operating Pressure 0l Other D Pressure psi Test Temp. 'F

I FORM Yz-ADM-080O.F02 REV 0 RTL ItA4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Reports available. Replacement in accordance with Code Case N-416-1.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Reolacement conforms to the rules of the ASME Code Section Xl. Repair Or. Replacernent Type Code Symbol Stamp N/A Expiration Date N/A Z_ Date July 21 _, 20 03 CERTIFICATE- OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT. have inspected the components described in the Ownees Report during the period /-" AF- 0.7? to '7-' -(, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owneres Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions ?9V r I Il-I L43Y National Doawd. Sate, Province. and ErotementS Date 7- Ast- 20 °3-

FORM WADM-0801.F02 REV 0 RTL # A4A 14-A Form No. 1590 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner F.E.N.O.C. Date 07/21/03 76 South Main Street - Akron. OH 44308 Sheet 1 of 1 (ADORESS)
2. Plant Beaver Vallev Power Station Unit No. 1 tAMn Shinninaoort. PA 15077 W.O. #02-014057-00 REPAIR ORGANIZATION P.O. NO, JOB NO, ETC.

. , k

3. Work Performed By FENOC-Maint. Services Type Code Symbol Stamp N/A (NAMP Shippingport, PA 15077 Authorization No. N/A (ADDWESS)

Expiration Date _

4. Identification of System Ventilation/River Water (03)
5. (a) Applicable Construction Code Section VIII 19 71 Edition, S72 Addenda;. N/ACode Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacements Components Repe. ASME Repbc& CoD&

Nom of Nam of M.a.ufacoz NgtbD- oid i Oqrh YeIr o, Stcd COAOotd Sua No. No. , kcouxauo W nlt Repc- (Y or

_ _ __ NO)

Heat Exchanger York 1-2239 46531 IVS-E-4B 1972 Replace- No

.. . imnt End Bell York N/A N/A N/A 2003 Replace- No

.nient

., >.c.-' -- _ ;

7. Description of Work Replaced heat exchanger end bells.
8. Tests Conducted: Hydrostatic [] Pneumatic a Nominal Operating Pressure 0 Other Dl Pressure psi Test Temp. OF

1L-FORM Y-ADM-0801.F02 REV 0 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks U-1 Data Report attached. The tube section of the heat exchanger was exempt to ASME Section VIII and was made to commercial grade. Previous NIS-2 Data Report Nos:1086. 348. 196.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and thi's ReDlacement conforms to the rules of the ASME Code Section Xl. Repair Or aReplacent Typo Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed 6VP & '. Date July 21 . 20 03 qtwor Ofwqes Deslwee roe

/

CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a vafid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT. have inspected the components descnbed in the Owner's Report during the period T'- 0.3 to 7- - S O 3 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner s Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

DZ J- Commissions '3 W uS A4 1 National Doard. State. Province. anrdEndlwsemewt 9({

Date '7- A Sr .,20 103

rG-2o.

V')U10t 11I MA-N11FACrt[;RFl1S'DIATA IRFPORT FoR PrmssuRE vF.ssrs A Tred )y theC Provrvionw! cf fhe~ASM roC~de Ridep. sectnn Vill. n;,;.;on I

%fillulicuiri~atliv2W'ORK Di ' BORG:WARNER CORPORATIONiYORK. PEHHSYL HIjA-U S. .

( ana 1emiGiiifls C ua Clrr Mi. EAE ALYPWRSTATION, :tnmju~ SHIPPIN'GPORT; PENNSYLV! AN.- -_

(N4ame And addresi of Purchateu)'.

~* orazK,~Ht.Exch'

  • ~* . ,* 453 ,, 2 IIrrVctt.l (17otkaC7cl d.fltAl Em-h.) &I1sfa)(tt Sae.Ro)

I es 3*4 o. T.tnpStdfl

.n~ei'l

'~~iIwl .ai air0(~l't 3cknei Or jaktC cie~.o et ~hn

-ht~o (Kind and %rec.1!i..I (ff eg hr FACtA Srec.Mln.T.S.) n A ow n . .Ii m .'

SIA%1ls- I on Seamless No i ~~f .~o NO II kI

WWdatd anlexlxaP.ltut C)

-s-b.1 (Yes tot Vo), (San' or CoMPrtet)**.. (Ye; of No), Vctrcside II(

(ah- .______ILLr _____ r_______ Sectioned No.ofC~oiar~civJ*

it. iI a iea t s i __ _ _ _ _ _ - _ _ _ _ _ _ _ TA . (hi M aterial u s. - ----

  • I ... at..n . Csouwn Knuckle ElliptkIca Coinical . lemkpheeat JFlaI Mid to1 ?ft*,iuII M-V.. Nolgt..m. eni) Thickne-vt tRadite' I(Adiut lRatio Apex Anlife R adu - - mete ri (Cfhea vlorCooncavel If trt-ti.vhk.. Iisft1 ttd -- Other I(a'tninir.

(tt'a.Se.N .... Sue. Nurroter) (D~esclibe ort Attach Sketch)

7. STAY ItfilS' Ifhollow - -Atuachment Pi_______l'ch X tMAM.

(Mtra)(Site ol' IItle) I . (Threadetd. Welded) (Iot.' .(Verf.) (Nomninal)

II. 1 (I.t&

JA(KI .cS1. u:elc It bar. give dImtensons.1If bolted. deacelbe ar skeldhl Q). ConasruttIcd ft-it m2x. *in

'11 Tcmp.(wAhcn *. . rrialic fr iril I trni 141IanaldII to tI- constlu ea for ftv %e ct ionl%. SA-9; I9;_7A-v,-1rZ-_ R 'and %A-?An - -I IAII f11Ai -

tln. T:Mt IES:ITTS: Stutmonnry. Wfaitiral __Sati...e5.i TbicknesiA 2 In, Attahment ........ e I dad Ml. .

(kind A Spec. Mos.) '(Subject to Pre-uatir) - (Wetded. uIt~ed)"

Il1autgn;. MAI~tciaI _______ -5ina;" I.Tk:x n Atlachmnent S inta I C S Iht . .SAtra o I4 IS.ndn3leuirrk-In.ii tteue I1 ineIlntcao hick..._ese. MBXr cannt of hgeaNti-eshan-cr.50______-_______I___t

52. sui~i ~ I %Iatr~jI . TS.Nominal rrsn (Kindi nd Srec. N-m.) IIg1.ar F.H. Spe1c. Mn.s T In.1 A~'ac...n a .. ;g..n ~n~l...11*...t I I.SI AlS: I-ir ... .I1.1. I. __ R r..T ...... Sectioned IsElkicnary ________1 Mgll%* SAIIIA le~ ~~ltIlc ll.ml~ aN. S-il or9Comprrole)

NV (Ye% tot Not) .ull a*C-Cg14swn Knuckle 8.1lti.lial Conical flemblaplerical Ila% SIdit-i. teIure -Z -

Umita~t-.ii rh...knei' Haditts Kadilus R(atio Apori Angpli Hadiusi Ilanorler iftfirnlyrti tot0neave)

If fern iial-le. N oll% uIowa1 l ._________________ (h)

  • ~ (MStict-iat. ,sptc. N".. ... %ire. Numtiei) .-

'.. .(lIksrutle oit Atflati Sketch) iS. 0u'r,.lru. rel i.fohila. Sf. n. rep (whern-- *~eY stLl 01 aloAle scsLnjgprcA%!.J.5 g'~lal maJ.- ICTr.n'.J5.0jr. .lsthii-20") *- *

  • r . 1 100 Psi~

.llnns_ below%itsbe Completed for all scudsi wheir applicable. .. .. ..

16 _FF__ALE____S-Natv . 12" L...ocationi_prendof hel Purt~ (Ik-. einforceme~nt *... 5o*y Outld.Vra3int NumI-I D~iano. of Size lype Maiterial 11-hicktscua MtAMA AlUctled ILn Ilet I 4" Pipe___SA-53-B Sch.40 SA-515-70 --Wel ded.-

outI__,_I41 _4_S_51_70 Welded-

_E zaI II 4" I /. t j p I ng___ A_-z.__2 ._1hAQ__ b

-A~eA lBl ..SA-J 5.2 .. 3.lbO ~

_.Coullg. . .. 2ei U~rotti~cid bcat-tas-ated. List undef rcmazks other internal os external pressures with coincident temnperaturi: when applicable.

- .C . .~

k~ ~R. k.6

U-N.B. 146531 Ill. INSPECTION Jlaaholes* No. *Size________Location____________________

OPENINGS:' liandltoles.No. Size L~ocation__________ _______

Tkieallej'4.*.* .lSze:* Location

19. SUPPORTS: ,'Airs ____________ Lugs Less :14soactb) MWi7.rL lIF.-

0.REMARKSI~. 16" ~Cnoser i - dorn (o~:rj1705I e~rvice) ___

Tube section code OMerrt U-I(d)(2) ...

4H nn-VAdna Hvyr.mtsttI c -test -5 p bfare.tubing a

-SA-z49rMAterIliI conforme. tQ 1113-9 Coni1tructel und jor the provisions of UG-9 C 2 ser~e5.. 1 p (0..5 p.. .1the Wesel. as At. Ts.n.Afl.r Co.1.1. .ek-i-dC-ok-.r. ct Sete. C..,..,. l. . .. h ie certify that the asateents mnade in this repret are cocrect and that all details of Jesign. matergeJ, construction. andl-o1k rnl

%ip of this vessel confers to the A-s4e C6de for Pressure Vesselt Section V .i i.tn Date August 7 ,972 YORKYRlViSOL, I H IB'dAgo.

-ARvwf kg  ;-

___g___

Critifljacte ol Authorijaitjm 8.F875 _. Fxr;,re%. DEO.cJ 31,_192J Senior E ifeer

'\'r X* .z :lxCER11FICATE' OF SHiOP INSIT(crlzy VESSEL MADEly¶ITYORK DIVISlON BORG-WAR$ER:CORPQFATION, YORK, PENHA. - U.S.A.

1.the sade;;4;ad. holding eAwid comamlaaloa Issued by ib ;tatal Bloetd of Boiler *nd Psessure Vessel Inspectors and/or theStateatPloincePennsYlvanIndmplojedby Hartford Steam BoiIer InsR. L Ins. Co.. Oi i-arfotd.-Conner.Utut h1velaaspected the prtsoure.vesaea described In this msnufacturer's Mntuey<lay 16 . i7. an4 slatce.that to the biet ofmy inowieide d.blttlef.'ie t nutsc.

IWer heo coaetructrd this pressure vessel In accoedance with the applicable secticas of the ASYE Bolle: snd Pressuse Vessel Code.

Bly signiag this cerillicate saeties (th inspector nor his employer makes any warranty, espressed or Implied, concerning the piesur. vessel described in thla..snufacturer's data teport. Furthemorte. neither the Inspector nor his employer shall be liable In my monetr for say peasosal Injusy or property damage at nalose of any kind atring from or connected with this inspection.

Date August7 19 72 v Commiasig ioss _ Nati, Bd Commn. 13695 Insecetor* sinlur-e" Xtl1. g1late,. Pf.ne AMN41. ....... n~n '1.

CEItTIFICATE OE FIELD ASSEIBLY INSPECl(ON

1. the undersigned, holding a valid commiss2on Issued by the Nationsl Board of Boiler and Pressure Vessel inspectors and/or tho State or Province__ d employed by ' of
. ! ,t1~ s
"* have compared the statements in this manufacturer's date report wIth tie described prqsut; v;es1el and state that parts referred to as data Items _

not lacluded. Ia the crtilcaetenf shop Inspectiot have been laspected by me and that to the best of my knowledge and belief the manufactaues has constructed and assembled this pressure vessel in accordence with the applicable sections of the ASUE 1 'Ilotlei' ia~ditsurw Vessel Code. 'TD described vesselwals nspected and subjeteci to a hydrostatic test of _ _ psi.

By olgalag this certificate neither the inspector nor his employer mskes any warranty. espressed or implied, concerning the press to vtesel described In thi's msnufacturer's data repoet. Furthermore. neither the Inspector not his employer shall be liable in ony;Usact fotr ?ny personal Ijuty 'or propertydansage or a loss of say kind atising from or connected with this inspectios.

SCommissions _ _ _ _ _ _ _d._______,

Z~s~peio~a Sm~tweNit'l Hcard. S~tate. Ircfe.jee a..S-..

I

. . . I . . . . .

FORM Vz-ADM-086I.F02 REV 2 .RTL # A4.414-A Form No. 1622 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions o f the ASME Code Section XI

1. Owner F.E.N.O.C. Date 121161 2004 (KAUE) 76 South Main Street - Akron, OH 44308 Sheet 1 of I (ADORESS)
2. Plant -- - Beaver Valley Power Station Unit No. 1 (NAME) " ' 3 M '

Route 168 - Shippinqport. PA 15077 Order #200024659 (AODRESS) Repair/Repdacsmen Orgaizabon P.O. No. Job No, esc.

3. Work Performed By BVPS-Maintenance Trpe Code Symbol Stamp N/A ME)

Rou le 168 - Shippingport, PA 15077 Authorization No. N/A (ADDRESS)

Expiration Date . N/A

4. Identification of System Chemical and Volume Control (02)
5. (a) Applicable Construbtion Code SectionVil 1968 Edition, -Addenda. - Code Case (b) Appricable Edition of Section X UtWzed forRepaidReplacernentActivity 989 (c) Applicable Section Xl Code Case(s). N/A
6. Identification of Components Caoreded. ASM.E Kerrow. CIP&

N&geer Naoo Nam 4o of

  • fMafcue M~faar  ; Nlarrtv bowd Nazioul . .

othfr Yew' or Stmdbed CeTw Mmratr SorW No. No Idemir~im Duik Bulk 1aldd (Ys or No)

Relief Valve Crosby 61680-003 - N/AA RV-ICH-203 1990 Corrected No Nozzle Anderson N94955-70-0096 N/A lIt #9K425 2001 Installed No Greenwood Crosby Disc Insert Andeson N94984-594078 N/A lIt. #A3QV 2002 Installed No Greenwood Crosby Spindle Assy. Crosby K55173-6012 NIA lit. #40912 1993 Installed No

7. Description of Work Overhauled spare valve by replacing disc insert, nozzle, and spindle assembly.
8. Tests Conducted: Hydrostatic El Pneumatic E Nominal Operating Pressure El Exempt 1J Other Pressure psi Test Temp. . .. IF
    • Recrd k Pressue wW tenperaboe

11-

w FORM Y2-ADM-0801.F02 REV 2 RTL It A4.414-A FORM NIS-2 (Back)
9. Remarks Previous NIS-2 Data Report Nos: 1554. 1016, 768. 757,445. 318. and 164. Spare valve AppkcaWe Wbaadur5s arta Rept Cobe arttc was bench set point checked. In Service Leakage Test will be performed when installed into plant.

CERTIFICATE OF COMPLIANCE I I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp _ NMA Certificate of Authorization No. N/A Expiration Date NIA Signed Owiw orOvw's Dersiee. Tab 6pp-I

. Ar Date January 18 20 05 CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned. holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of _ Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owner's Report during the period c/_-.Z 6 #3 to /L/ - L . and state that lo the best of my knowledge and belief. the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

2 eAr J Comms~ins Commisvions -z-, C!X Nagknl B05d. batPrMve Staae and Efdomer Date / /0 , 20 Adr

..- I .

FORM %-ADM-0801.F02 REV I RTL # A4.414-A Form No. 1642 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner FENOC Date Auaust 15. 2003

- (NAME) h e t 76 South Main Street - Akron. OH 44308 - Shieet 1 of 2 (ADDRESS

2. Plant Beaver Valley Power Station Unit No. 1 (NAME)

Shipoingport, PA 15077 W.O. No. 02-008296-002 (ADORESS) Repak/Replacer*OanztOP.O.No_ Job1_etc.

3. Work Performed By BVPS Construction ~ Type dcde Symbol Stamp N/A (NAME) k Shippingport, PA. 15077 Authorization No. N/A (ADORESS)

Expiration Date N/A

4. Identification of System Unit #1 Containment Instrument Air (System 34)
5. (a) ApplicablebConstucionCode ANSI B31.1.0 1967 Edition, S 1971 Addenda, NrA Code Case (b) Applicable Edition of Section Xl Utilzed for Repairs or Replacements 1989. No Addendum (c) Applicable Section Xl Code Case(s) NA416-1
6. Identification of Components ,I Coecle ASME R. one . COE '

Name d Namco Madnadzier Na.i-ng ,- o.' Year o Smped Cpoe MarAa r SeM No. Board Idebiftawn Built . st aed (Yes or No)

Trip Valve SPX Valves 0220-97399-1-1 NrA . TV-11A400 2003 Installed No (1/4 Turn and Controls .

EWterify) .- ...

Gate Valve Velan 0010254 NIA lIA-904 2001 Installed Yes Gate Valve Velan 001025-6 N/A I IA-90-1 2001 Installed Yes Gate Valve Velan 001025-5 WNA 1IA-90 2001 Replacement Yes Gate Valve William NWA WNA IlA-90 N/A Remwved - No Powell Co.

Piping BVPS NiA N/A 2-ACC-34-151-02 2003 Replacement No Piping BVPS. NIA NIA 2-ACC-35,151-02 2003 Replacement No Pipirg BVPS NIA N/A 2-ACC-113-151-02 2003 Replacement No

7. Description of Work:

Modify pDitfnl and valves as part of ECP 02-0079 to eliminale the Containment Instrument Air Compressors. located inside Containment. They will be replaced by cross-connedinq the Station Instirrment Air System to the loads in containment via this modification to provide a more reliable system.

8. Tests Conducted: Hydrostatic a Pneumatic E Nominal Operating Pressure E Exempt 0 Other 0 Pressure psi Test Temp. °_F

FORMANI-ADM-0801.F02 REV I RTL NA4A 14-A FORM NIS-2 (Back)

9. Remarks: No Code Data Reports available. ASME Code Case N-416-1 was utilized for performance and system leakage test in lieu of the hydrostatic pressure test.

wppcable MamAadwaes Data Reports lo be auached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code.

Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expirain Date NIA Signed: Michael A. Gerardi J Date August 15.2003 . 20 04 Owr at OHWs Desgrte rae -e CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned. holding a valid commission issued by the National Board of Boller and Pressure Vessel Inspedors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT. have inspected the components desaibed hi the Owners Report during the period 1017101 to 4/26103. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xi.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. -Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or properly damage or a loss of any kind arising from or connected with this inspection.

c9 _I X Commissions -t-, V e tY A~*

Naial Boad Sle frowxe an Endorseoierus I s Soiature Date 3- A G 20 0 Vt

(CvZ..

DATA PACKAGE NO. 011025 FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES

  • As Required by the Provisions of the ASME Code,Section III, Division 1 Pg. I of 2 1;- Manufactured and certified by VELAN- INC.) 2125 WARD AV9,MONTREAL.OUEBEC CANADA u4M1T6 (namead addressorN Certificate lolder)
2. Manufactured for'FRAMATOHE TECHNOLOGIES 3315-A OLD FOREST RD.LYNCHBURG.VA.USA 24501

(-ame sod addres ofpurclier)

3. Location of installion N/A

(--niw andiddres)

4. Model No., Series No., or Type: GATH Drawing P1-76800-N21 Rev H CRN N/A S. ASME Code, Section III, Division 1: 1i89 NB9 1 .LA (editio) (addetds daie) (cus) (Code Case o.)
6. Pum or valve VALVE Nominal inlet size. 2 Outlet size 2
  • a )Bd Dn)
7. Material: Body, SA-182.7316 BonnetSA-182, F31S Diskc SA-351.CF8N Bolting SA-l94SM

. p. SA-564, 630H11100 (a)- '(b) (c)

I- . (d) . . (e)

Cert. Na't 1 Body-' Bonnet - -- Disk Holder's Board Serial Serial Serial Serial No. No. No. No. No.

011025-1 N/A H/C: CCB T/C: BVT R/C: 621!

.u

^Vq.. uc ftC CCR BVT 621!

011025-3 -CCB BVT = 62Fr 011025-4 BVT 66Er 011025-5 - -

CCE BVT 62Fr I.. 011025-6 CC8 BVT 62Fr 011025-7 . .

- - -CCE BVT 621!

011025-8  :

CCE. -621!

011025-9 CCE BVT . 6211 011025-10 CCB BVT 62H wa st.=was I=

7 r-w

- I * ..... .

-. .. .. . . -. F. . .I

' , . . I , . . I... . -

Sieformation In form oflists, sketches, or drawincs Way be s" vided (1) sie iS m 1/1 ,(2) Inforsiatioa in Oles I through 4oathis Data Incdedo each aet,(3)eachadsnumredandthenumberfsheetssrecordedattheo bbIs f ts _form Ii form (E80037) may be obtained from the Order Dept, AS%:, 22 LAW DRIVE< BOX 2300 Fairfield, NJ 07007-2300 o Sp 17to'S... '! .. -

. - .:-IA. .

4.

.3. ui-&-a

.. . .. Ya .

  • na*-' V (IF

I*

FORM NPV-1 (Back - Pg. 2 of 2 )

Certificate Holder's Serial No. 011025 B. Design conditions 1920 psi 100 *F or valve pressure class 800 (1)

(pressure) (temperature)

9. Cold working pressure 1920 psi at 100F
10. Hydrostatic test 3000 psi. Disk differential test pressure 2200 psi
11. Remarks: MATERIALS mRsT ASms SECTION rr EDITION: 1989 ADDENDA: NONE I

CERTIFICATE OF DESIGN Design Specification certified by  ?.LAVIGNN P.R. Stat. OgN Reg. no. 40052 Design report certified by S. ISBITSKY P.R. State OUB Reg. no. 22115 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No. N-2797-1 Expires APRIL 20,. 2004 Date I O Name VELAN INC. Signed (NCertiricate nolder) (sutboried rstative)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Q'UBBBC and employed by

-REGIE DU BATIMENT of OURBEC have inspected the pump, or valve, described in this Data Report on J/1c10 Ile, and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASHE Code,Section III,.Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with t at inspection.

Date O 2.jO°/.. signed Commissions _BB

.(Artlerhd Inspecor) (NML BId(mincendorsments) srd lRA-Alq.

state or prey. and o) IP SuP (1) For manually operated valves only.

. I

i.

FORM /2-ADM-001..F02 REV 2 RTL # A.14-A Form No. 16816 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl -

1. Owner F.E.N.O.C. Date 12/16/2004 76 South Main Street - Akron, OH 44308 Sheet I of. 1 (AOORESS)
2. Plant Beaver ValleV Power Station - Unit No. 1 RN A1 6 S hi n n n P A 15 -in .: I Route I168 - Rhinniriaort. PA I 15077 Order #200022048 ADODRESS) ReraIRerplacentm Orgarization P.O. No. Job No, etc.
3. Work Performed By BVPS-Maintenance TypesCode Symbol Stamp N/A (HAU ,E)

Rout e 168 - Shiopingport, PA 15077 Authorization No. - N/A (ADDRESS)

Expiration Date N/A 4.. Identification of System Fuel Pool Cooling (Q3)

5. (a) Applicable Construction Code ANSI B31.1 1967 Edition. S71 Addenda.' NIA Code Case (b) Applicable Edition of Sedion la Utilized for Repatr/ReplacemnentActivity 1989 (c) Applicable Section Xl Code Case(s):NA -,
6. Identification of Components Co!-ec'd. ASME Remioved, code Non of Njno or Ma'nurli, H.aow Boad ohr Wa or Szmiyd C r y m aurer Serial No. No Idoifrcaon . 8ik instAed (Yes or No)

Check Vatve Pacific . vN/A IPC-108 1976 Corraecd No Plug Pacific N4/A N/A H-t. REWII 2004 Installed No

7. Description of Work Replaced hinge bin pluNOs.
8. Tests Conducted: Hydrostatic *[ Pneumatic*5 Nominal Operating Pressure 0 Exempt[]

Other IIJ Pressure psi Test Temp. ___ OF

'ReId lesApressureand lefsperahoe

r FORM 'r-ADM-080I.F02 REV 2 RTL H A4.4 14-A FORM NIS-2 (Back)

9. Remarks No Code Data Reports available. *year installed.

Appkcase Manufad.er's Data Repots to be aMadxed CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp. N/A Certificate of Authorization No. NWA Expiration Date N/A Signed $DateI 20 DV

% Own or Owners Desigr". Tie O

CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned, holding a valid commission issued by the National Board of Botler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSQ CT of Hartford. CT have inspected the components described in this Owner's Report during the period ____(e____ to /eL d 4 ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or imnplied. concerning the examinations and corrective measures described in this Owner's Report Furthermoe, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Comrnissiqns I37"I `0A hi 5spature rd. State. 'rowve. and Endorsees Date / - A a- - 20 9V

FORM %-ADM-0801.F02 RREVT2 RTL # A4.414-A Form No. 1689 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY ,,

As Required by the' Provisions of the ASME Code Section Xi

1. Owner F.E.N.O.C. Date 12115}f2O04 76 South Main Street - Akron, OH 44308 Sheet 1 of 1 (ADORESS) 2- Plant - Beaver Valley Power Station - Unit No. 1 Route) 1 P 150 77 Route 168 - Shippingport, PA 150i77 Order #200045735 (ADOnESS) RepairReplamncet Orgarization P.O. No. Job No, etc.
3. Work Performed By BVPS-Construction Services TypeCode Symbol Stamp - N/A (NAME)

Roulte 168 - Shippingport, PA 15077- Authorization No. N/A (ADORESS)

- , Expiration Date N/A

4. Identification of System Reactor Coolant (Q1)
5. (a) Applicable Construction Code ANSI B16.5 1968 Edition,. Addenda,. -Code Case (b) Applicable Edition of Section )a Utilized for Repair/Replacement Activity 1989 (c) Applicable Section Xl Code Case(s): NA4162 0.
6. Identification of Components co..e.de. AS'E Naurof Nam of Mtad . N o.ifBerd Oter YCW or Stped C- ,c m ma..rac.r Serial t-o- No. IdatdirK;oDn Bah . Iazd (Yes or No)

Gate Valve Velan - . N/ MOY-IRC-535 _. Removed No Gate Valve Velan 042060 N/A MOV-IRC-53S 2004 Installed No

7. Description of Work' Replaced valve with spare.
8. Tests Conducted: Hydrostatic' E Pneumatic' l Nominal Operating Pressure CD ExemptE Other E Pressure psi Test Temp. °__

ID_F

'Record lest ptessure and terrperakre

FORM 'A-ADM-0801.F02 REV 2 RTL ffA4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Original valve also designed to MSS-SP-66A. New valve Apicabte Manufacturees Data Repots to be attadced Designed to ANSI B31.1 67E and ANSI 816.34.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that\this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp NIA Certificate of Aqthoriation No. NIA Expiration Date NIA Signed 7T 5 - 4 z Date January 11 , 20 05 L,- Oner or owrehs Desigee Titse r CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owner's Report during theperiod B- '2 - to , 5 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

,bsped )nat 9 xe Commissiclns , 1/4:

~~ r Hatiason8Zg/d. State. PrmWce, and Endorsements Date /-/I2 - 20 'f

. v FORM 91-ADM-0801.F70 REV 2 RTL # A4.4 14-A Form No. 1690 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C. Date 12/17/2004 (NAME) 76 South Main Street - Akron, OH 44308 - Sheet 1 of 1 (ADDRESS)
2. Plant Beaver Valley Power Station Unit No. 1 (NAME)

Rohite 168 - Shinninanort- PA 15077 Order #200043580 (ADDRESS) RexwtRedplacerent Orgarmzation P.O. No.. Job No, etc.

3. Work Performed By BVPS-Construction Services TypS Code Symbol Stamp N/A QLAME)

Route 168 - Shippincport, PA 15077 Authorization No. NiA (ADDRESS)

Expiration Date NIA

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S71 Addenda. NIA Code Case (b) Applicable Edition of Section Xl Ublized for Repair/Replacement Activity 1989 (c) Applicable Section XI Code Case(s): N-412
6. Identification of Components Cowrrmd. ASME

.cmo..d. CO.E tNarmof NinmeC Mof Nati board Other Yw or Stumed Coeponent macsure ' Sert No. tNo. tdcn~tis;ion B.o -Ystad S r No)

Pipe FENOC N/A N/A WR-649 2004 Installed No Pipe . FENOC. N/A N/A WR41 2004 Installed No Gate Valve Crane - N/A IRW-140 1976 Rernoved No

7. Description of Work Replaced pipeffittinos on pipelines WR-41 &WR-649. eliminated valve IRW-140.
8. Tests Conducted: Hydrostatic* E] Pneumatic* E Nominal Operating Pressure ED Exempt E Other El Pressure psi Test Temp. °_

IF

'Recrrd test presswe and terrpeslsre

FORM Vr-ADM-080I.F02 REV 2 RTL # A4.4 14-A FORM NIS-2 (Back)

9. Remarks No Code Data Reports available. Replaced: 3" NPS Pipe Ht. # A41651: 3" Flange(s) Ht.

Applicable MaWnutwees Data Reports lo be atadwed

  1. A22/2. Ht. UA24; 4 Pipe Ht. #N07061: 4" x 3 Reducer(s) Ht. # 188WNB-1. Ht. #188WNB-2; 3" Elbow(s) Ht. #H497AC, Ht. #PBJ202F; 4" x 3" Reducer(s) Ht. #71OUNC-2. Ht. #7 1OUNC-3:

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code. Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date NIA Signed - :5Vi rEpcrJ41'; Date o0Ter or OvhmeesDesignee. re I _. .tI CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owvens Report during the period Y A 1- - 4 3 to Z-Z - A-X- Of, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owneres Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

AgJ)--a, 's~Siganxe m-/n Commniss"~sL/A/

mbNor oard. state. rronce. and Ladosernents Date .,20 K0 Date 20

FORM %rADM-080l.F02 REV 2 RTL A4.4 14-A Form No. 1697 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions iof the ASME Code Section XI

.9

, .!  ;; *1  ; . *: .. -

1. Owner F.E.N.O.C. .-- . Date 01/10J~2005 (NAME) 76 South Main Street - Akron, OH 44308 ---- - Sheet 1 of 1 (ADORESS)
2. Plant Beaver Valley Power Station -- Unit No. 1 tAm"W 5Thinninnncnrl PA I qfl77 Order #200072000 (ADORESS) . R,Reptaosenl Orgarzation P.O. No, Job No, etc.
3. Work Performed By FENOC-Construction Serv. Type Code Symbol Stamp NIA (NAME)

Ship ninaport, PA 15077 Authorization No. 'N.A (ADORESS)

- -Expiration Date . I I.
4. Ideritificalion of Systemr Recircilation Spray (Class C) .
5. (a) Applicable Construction Code (b)

(c)

SerbonlH -

Applicable EdiGon of Section Xl Utilized for Repair/Replacement Activity Applicable Section Xl Code Case(s): NM*IA

6. Identification of Components 1968 Edition, W'68 1989 Addenda. NtACode Case I If-'

Concused. ASMEE NNWof Name of Mjnufjs ' N lil Dowd Oiber Yw ofm St-ed C nc :v C um Serib, NO. NO.- Idimioo Buik I'snstaled (Y- m )

Heat Exchanger Industrial 6301-1 3179. . IRS-E-IA . 1971 Corrected YS Processes

7. Description of Work Replaced diaphragms and seal welded, repaired-lower flanqe.-
8. Tests Conducted: Hydrostatic' E Pneumatic EO Nominal Operating Pressure lN Exempt El Other Q Pressure - psi Test Temp. -- F Recrd best pressue and lenVerature

FORM '4-ADM-0801.F02 REV 2 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Previous NIS-2 Data Report Nos: 1577. 1417. 1251. 945. 854. 697. 595. 557. 435. and Appsikbe M sisadurus Data Rep"a bo be adtoed 295. Copy of original Code Data Report in NIS-2 Report No. 1577. Lower flange was repaired to correct a grinder gouge mark.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that tHis conforms to the requirements of the ASME Code, Section Xl. X Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date. NIA Signed g Q) - &.iho `~r _MA^Cf

,ee-7, &A f Date _ January 10 20 ns.0 ':.

- IC- Ow Cor Owne's Desigee- Title I CERTIFICATE OF INSERVICE INSPECTION

1. the undersigned, holding a vartd commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of /719 and employed by ALd C 7of

~er 4. o' c.. A, have inspected the components described in this Owner's Report during the period { V.Z ° a to . /-n and state that to the best of my knowledge and berief, the Owner has performed examinatigns and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the inspector nor Ns employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owne's Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions 4 4~ Z% g 4 ' Jsgnalte Nabmsl soare.stae.

S Pep and Eruosements Date /2 4L , 200 J-S-5

FORM V.-ADM-0801.F02 REV 2 1. - RTL # A4.414-A Form No. 169 8 Rev.1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner F.E.N.O.C. Date 01/10/2005 NAME) 76 South Main Street - Akron, OH 44308 - -Sheet 1 of I (ADORESS)
2. Plant_ Beaver Vallev Power Station Unit No. 1 Shirminanort, PA 15077 Order Nos. 200071998. 200066742 PDORESS) RepaireReplacernit Orgaiza5arn P.O. No-. Job No, etc.
3. Work Performed By FENOC-Construction Serv. Type Code Symbol Stamp NIA Shin)inqqort, PA 15077 . Authorization No. N.A (A*xoRESS)

Expiration Date __ _ _ _ _ _ _ _ _ _ _ _

4. Identification of System Recirculation Soray (Class C)
5. (a) Applicable Consbiuction Code - Section III 1968 Edition. W68 Addenda. WA Code Case (b) Appricable Edition of Section Xl Utitized for Repair/Replacement Activity 1989 (c) Applicable Secion ) Code Case(s): /A
6. Identification of Components Cordectd ASME Ree .'Cod.

Ntre of Name of Pmufaciwer . ioW 5"ard Other Year r .

ol S1tad Co en tl .. m wucte Serial NO, No... ldcwaificaloo Built lIstallod (Yes or NO)

Heat Exchanger Industrial 6301-3 3181 IRS--I'C 1971 Corrected Yes Processes

7. Description of Work Replaced diaphracims and seat welded. plunged and seal welded nine tubes.
8. Tests Conducted: Hydrostatic El Pneumatic' E Nominal Operating Pressure ED Exempt E Other El Pressure - psi Test Temp. - OF

-Record Lestpressure and keirperakire

FORMt Yr-ADM-080I.F02 REV 2 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Previous NIS-2 Data Report Nos: 1578.1418.1252.946, 855 698.689, 596, 558.486.

A~ppice Uartacurus Data Repofts t be aftadied 288 and 156. Copy of original Code Data Report in NIS-2 Report No. 1578. Tube plugs Ht. No.

D89473A CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that This conforms to the requirements of the ASME Code.Section XI.

Type Code Symbol Stamp NIA Certificate of uthorization No. NIA Expiration Date NIA Signed 601,'zr Hor4i /l Date January 19 20 05 X. Ownrw Owmees Desrioee. Tile I CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of /1 L and employed by Ad4 _C7 0rof

,o (e d -7 have inspected the components described in this Owner's Report during the period C-Afto 43 to /-'2/ - rsf and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

S'az' -J. Z" Commissins ,'s 9o' k at 5y 4 wff7 Pe A'3 oad. State. Piyne. aWd nrsevents x

Date /- 0Z1-2 , 20 3/6-

FORM Yz-ADM-080 1.F02 REV 2 RTL g.A4.414-A Form No. 1699 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code'Section Xi ' -

1. Owner First Energv Corn - Date - November10 2004 NAMc) . . _

76 South Main Street. Akron. OH 44308 : - Sheet .I 'of 2

  • (AfC ESS) . .
2. Plant Beaver Valley-Power Station .  : Unit No.
  • -Rinnn P
  • Shinninn n~ft PA 15l)7.7 ..g rinni 9i

. ADORESS)  ;-,- - Repaw mr orgar P.0, tNo; Job No, etc

3. Work Performed By FENOC - Construction Type Code Syrmbol Stamp. NIA
  • (NAME) ..

Shiprinaiort, PA 15077 Authorization No.- N/A' (ADDRESS)

Expiration Date N/A

4. Identification of Systern' Feedwater. BV-1-24-Svstem (Q3)
5. (a) Applicabl Construction Code ANSI B31.1.0
  • 1967 Edition. S 1971 Addenda. : Code Case (b) Applicable Edition of Section Xi Utilized forRepair/Replacement Activity 1989 (c) Applicable Section XI Code Case(s) N416-2. .
6. Identification of Components . , . , ..  ; . '

Covredcd.ASM~E rime or Nameof WoMam~fadr

.e- ' O d

  • Yer YwS-

.. Code

. -w Co¢,%o Mdfn sal NO. Dow ldcdifile Boik built Installed (Y.. Ho)

Ne FE-IFW-I01A VALCOR I -. 2002 INSTALLED NO

7. Description of Work Installation of cavitatinq venturis into the Auxiliary Feedwater System lines feeding the steam generators
8. Tests Conducted: Hydrostatic^ 5 Pneumatic El Nominal Operating Pressure l Exempt El Other 5 Pressure Normal psi Test Temp. Normal OF

'Record lest pwessre andtternperahe

FORM 'M-ADM-080LF02 REV 2 RTL NA4.414-A FORM NIS-2 (Back)

9. Remarks Applcable Uar eaburs Data Rqxots to be tadied CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A '

Certificate of Authorization No. N/A Expiration Date N/A Signed -

14"Je Iod- Date . 1 c/I q 20

.vewOeg's Des4 . rame -r CERTIFICATE. OF'INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors andtheStateorProvinceof e/ . aindemployedby *.#JS C7of Wfr't 7d Ad d C V have inspected the components described in this Owners Report during the perod __-_2(e__<)_3 to fZ - GP and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

2'1 .- Commissions -r- 1'4-_38-Natiow Board. State. Promirce. and Enhsoerds i

Date -;' 6 - , 20 d Yz

FORM Sr-ADM-0801.F02 REV 2 RTL # MA4I 4-A Form No. 1700 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner F.E.N.O.C. Date 01113/2005 (NAME) 76 South Main Street - Akron, OH 44308 --. Sheet 1 of _ 1 (ADORESS)
2. Plant Beaver Valley Power Station Unit No. I (ARM ) . .. ..

Route 168- Shiooinaoort, PA 15077 Order #200091968 (ADDRESS) Repak*Re/aceffertt Orgadzubf P.O. No, Job No- ec.

3. Work Performed By FENOC-Maintenance Tye Code Symbol Stamp .'NIA Rout e 168 - Shipoinaport, PA 15077 Authorization No. N/A (A-OREMD

-Expiration Date N/A

4. Identification of System Chemical aid Volume Control (Q2)
5. (a) Applicable Construction Code -- 831.1 - 1967 Edition. .S71 Addenda. N/ACode Case (b) Applicable Edition of Section Xl Utirized for Repair/Reptamnt Activity 1989 (c) Applicable Secton XI Code Case(s): N41  :'-2
6. Identification of Components Corrctdod ASME Rireusvod. Codc Nam of Name of m"Urasctuw Natonl BoDwdOther Yw e Coe o Mangitdur Serai No No Lkwoiica;on il Insialed (Yes f No)

Piping Stone & Webster N/A N/A FE-1CH-130 1976 Corrected No Flange Energy Process N/AI 11t. 131909 2004 Installed No

7. Description of Work Replaced flow element flange.. studs and nuts.
8. Tests Conducted: Hydrostatic' 5 Pneumatic* D Nominal Operating Pressure E Exempt 5 Other El Pressure psi Test Temp. _ _ OF

'Record lest press e ard leroate

FORM '/-ADM-0801.F02 REV 2 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Reports available. year installed. Replaced lower flange on flow element.

AWcglIe uWX4Xkffs Data Repoft to be AtbOW New 718" NPT studs: Ht. #7528A1 86. nuts Ht. #HOT.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp NWA Certificate of Authorization No. N/A Expiration Date NIA Signed Go~ *P6, .

1;r Date January 21 20 05

% Owner or Owners Designee.it '

CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsyivania and employed by HSB CT Of Hartford. CT have inspected the components described in this Owner's Report during the period X/- vt to /-

./(S .anddstatethattothe best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code. Section XM.

By signing this certificate neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Owne's Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

.1 J_ .-L-Un os Sgnature Commissipns i, Naboal 1Ad. State. Prof ch aMd Endlorsernes Date / 02/s z

FORM YAADM-080 1.F02 REV 2 RTL # A4.4 14-A Form No. 1707 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner F.E.N.O.C. Date 01/12/2005

{NAME) 76 South Main Street - Akron, OH 44308 .. . Sheet 1 of 1 (ADDRESS)

2. -Plant Beaver Valley Power Station . . . Unit No. 1 RuAME) 168 h P. .. .

Route 168 - Shiopninaort. PA 15077 Order #200102418 (ADOR RESS) RepakWRepacement Organization P.O. No. Job No, etc.

3. Work Performed By, FENOC-Maintenance Type Code Symbol Stamp - N/A (NAME)

Shippinci port. PA 15077 Authorization No. N/A VADOR aSs)

Expiration Date N/A

4. Identification of System Chemical and Volume Control (Q2)
5. (a) Applicable Constuction Code 531.1 1967 Edition. S71 Addenda, NA Code Case (b). Applicable Edition of Section XI Ublized for Repair/RepLacement Activity 1989
  • (c) Applicable Section XU Code Case(s): N-41r&2
6. Identification of Components Co.:rk.l, ASME Itenovok COde NnM of nam of Mamu.actwe ' Natonal Dowd olhuf Yce or Shurped Conoocot Mawinfacw Scei No. No. ldcnrMi;on Built Lital (YcSor No)

Globe Valve RockwoeH - N/AI CH-175 1976* Removed Edwards Globe Valve Edward Vogt _ N/A. ICH-175 2001 Installed No

7. Description of Work Replaced valve with spare.
8. Tests Conducted:. Hydrostatic 0 Pneumatic'l Nominal Operating Pressure 0 Exempt El Other O Pressure psi Test Temp. OF REcrd lest pressure and tenrpe ure

.D FORM Y/-ADM-080I.F02 REV 2 RTL ItA4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Reports available. Original valve was designed to B1 6.5 1968E.

AppIbLe naachuxs Data Repos to be affadwd

  • year installed. Valve serial number was not recorded.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xi.  %

Type Code Symbol Stamp NIA Certificate of Authorization No. NIA Expiration Date N/A Signed <°VA ' , 4no/13- Date January. 17 I 20 05 (ocr or Ohes Desriow rie '

CERTIFICATE OF INSERVICE INSPECTION

1. the undersigned, holding a valid commission issued by the National Board of Boler and Pressure Vessel Inspectors and the State or Province of. Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owner's Report during the period  ;/A ( - 3 to L ^ aand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corredive measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's ReporL Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commiss' s AILS f lJ i f l Rae m

/44 AZ32?

Stase.F'ramn. and Endomsents Date /-/72 , 20 ~

FORM %-ADM-080 1.F02 REV 2 - RTL # A.14A

Form No. 1708 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the.ASME Code Section Xl

1. Owner F.E.N.O.C. -. Date _ 01/12/ 2005 (NAME 76 South Main Street-Akron. OH 44308 - - -- Sheet 1 of I ImOmSS)
2. Plant - Beaver Valley Power Station - - Unit No. 1 (NA ME) I ' --  :-

r 18 - Shinninnonrt PA 15077 Route Order #200102056

  • OARESS) , . . ,. Repaor/iFcemnwd Orgarizabon P.O. No, Job No. etc.
3. Work Performed By FENOG-Maintenance Type Code Symbol Stamp - N/A (NAME)

Shippingport, PA 15077 Authorization No. N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Chemical and Volume Control (02)
5. (a) Applicable Construction Code B31.1 - 1967 Edition, S71 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utiized for RepaidReplacement Activity 1989 (c) Applicable Section XlCode Case(s): N-416---2
6. Identification of Components

.. ASME

.e"Ved. Code Nave of NrmK of MSetwr Naib'a Board othes War or St-red Conad . 14l"Uffwr saw No. No. Identjf"cst B-uilbt Injed (Yes or No)

Globe Valve Rockwell- NN/A ICH-177 1976'. Removed No Edwards Globe Valve Edward Vogt - NIA  : CII-177 2001 Installed No

7. Description of Work Replaced valve with snare.
8. Tests Conducted: Hydrostatic E Pneumatice O Nominal Operating Pressure 0 ExemptEl Other ] Pressure psi Test Temp. OF

'Re d tet pressure and tewrperature

FORM 'A-ADM-0801.F02 REV 2 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Reports available. Original valve was designed to B16.5 1968E.

Apoicabte Marhtadaers Data Raepot tobe aftaded

  • Year installed. Valve serial number was not recorded. '

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conformns to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N(A Expiration Date NIA Signed 1L , a -

. 7 t<~/I%.r Date ZL"7 - ItI 20 OS t-0 or OwhCs Desinee. Tre CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned. holding a valid commission issued by the National Board of Boler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owees Report during the period /-cZ. - jq(3 to /-/-7-A - andsttetthattothe best of my knowledge and belief. the Owner has performed examinations and taken corrective measures descibed in this Owners Report in accordance with the requirements of the ASME Code. Section XA.

By signing this certificate neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Ownee's Report Furthermore. neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

______Co__ Corrmissions 3 Ad /t f,s efau Naticrad 1"rd, State, Prowome and Ene Date /2 / 20 0

FORM %ADM-080l .F02 REV 2 RTL # A4.414-A Form No. 1709 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner F.E.N.O.C. - ' Date 01/13/2005 NAME) 76 South Main Street - Akron. OH 44308 -- Sheet I of (ADORESS)
2. Plant Beaver Valley Power Station - - ^ - - Unit No. I R etME) P1 I Route 168 - Shippinciport, PA 15077- Order #200070073

. (ADORESS) repwiReplacentne Oraiaon P.O. No_ Job No.. etr.

3. Work Performed By FENOC-Maintenance TypeCode Symbol Stamp - N/A (NAM) P Route 168 -Shi~oingport, PA 150&77 Authorization No. N/A -

- Expiration Date N/A

4. Identification of System Main Steam (02)
5. (a)Applicable Constction Code B31.1 1967 Edition, S71 Addenda. N/A Code Case (b) Applicable Ediion of Section Xl Utiized for Repair/ReplacementACtMty 1989 (c) Applicable Section Xl Code Case(s): WA1-
6. Identification of Components C;O. . AS. E Nerwor Nwme of Mam rr . 4i0 d 2B Ot.her Year of SzWed C , wrial Sc. No. NO. Iderldiicrion B b lmufd (Yes )

Nozzle Check Enertech 10549 N/A IMS-I9 1997 Removed Yes Nozzle Check Enertech 11075 N/A IMS-19 2001 Installed Yes

7. Description of Work Replaced vahie and inlet/outlet flanqie studs. -
8. TestsConducted: Hydrostatic*[] Pneumatic' O Nominal Operating Pressure E Exempt 0 Other 0 Pressure psi Test Temp. °_F
  • Recrd WMs pressure and leapemkaie

FORNM Y2-ADM-0801.F02 REV 2 RTL NA4.414-A FORM NIS-2 (Back)

9. Remarks Code Data Report attached. Previous NIS-2 Data Report Nos: 952, 824. 759. 497, 263.

ApHotie MwUxadaxWs Da Rewft to be aced and 143. Valves were supplied as ASME Section III 197i E-S'72A but are installed in a B31.1 system. New 3/: studs: HL#t.P 127. Valve serial number 11075 had the disc replaced Der P.O.

55100560. new disc Heat Code KUJ-3489.

CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl. X Type Code Symbol Stamp, WA Certificate of Authorization No. NWA Expiration Date NIA Signed

%w O~vw e Ohnes Des".

Tade

- 5$:Te

?f:.oi; /,3r Date January 24 20 05 CERTIFICATE OF INSERVICE INSPECTION

1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB Cr Of Hartford. CT have inspected the components descnlbed in this Owner's Report during the period 9- z G - F3 to /-X YZ-/ . and state that to the best of my knowledge and befef, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

W- J J, `-`ln"ure CommissinIns Add sr and E3 Te Naturea Dowd. Sm..e Prowace. and Ergdreet Date /A- A YV-

ii otjv FORM NPV1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES' As Required by the Provisions of the ASME Code. Section Ill. Division 1 Pg. I of 2

1. Manufactuwed and ceftimed by Enertech. A Div. of Curtiss-Wright Flow Control Corp.. 2950 Birs h Sb. Brea, CA 92821 (name d address of N Certficate otbderd
2. Manufactured for First Energy Corp.: P.O. Box.361 1; Akron. OH 44309-3611 tmaine and address of Purchasei
3. Location of instaltation Beaver Valley Power Station; Route 168; Shippingport. PA 15077 (name and addiessl
4. Model No.. Series No., or Type DRV-Z --DraWV PD98401 Rev. E
  • N None 5: ASME Code. Sect III. Division 1: 1971 S72 3 None ledition) (addenda datel Idass) ICode Case no.1

_ .. Noze z Chedc Vatve .. A_ . 3 - 3

b. rump or valve--- nla owet size %jutulc. stze (inl.) lin.l
7. Material: Body SA-105 Bonnet ' N/A Disk SA479 Type 316 Eotitg NIA (al lb) (dl Iel Nat'l , I oI. I Bonnet Disk Holder's Board -. ' Set'ial ' Seeria Serial Serial No. No. *' ' No. - No. No.:

11075 None KEI-001 None

  • JKT-023 11076 ' None - KEI-002 None JKT-024

, F .  ; _ .. .. . .

.. t;-

@ . - -. a, - , .

s - -- . .

tSupplementalInformation i form ofetesu:sketches. or.drawkvs may be used provided I I I size s 8 Y x I 1, 121 idormstiomn in hiems 1 through 4 on this Data lePOrt Is induded en each sheet. 131 eadi sheit is numbered and the number of sheetsis recorded at the top of this form.

(121881 This form J(000371 may be obtained from the Order Dept.. ASME. 22 Law Drive. Box 2300. Fairfield. 14J 07007-2300. fl(PItIN. G693

FORM NPV-1 (Back - Pg. 2 of 2 )

Certificate Ifolder's Serial No. 1 1075 & 11076

8. Designconditions 1100 psi 560 *Forvalvepressuredass 60() _I) tpressurel (tempealuIel
9. Cold wording pressure 1440 psi at 100I F
10. Ifydrostatic test 2175 psi. Disk uijferential test pressure 1600 psi
11. Remarks: Qty. 2, Eneitech Job Number 24628V CERTIFICATION OF DESIGN \

Design Specification certified by Francis W. Gardner P.E. State PA 'aeg,no. 036614-E Design Report certified by Ira J. Silverman P.E. State CA Reg. no, 23241 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code, Section lIl. Division 1.

N Certificate of Authorizationo N-2826 e 10/26102 Date 3ame Enertech (N Certificate Hogderl ned =*, I7 (anharked representadvel CERTIFICATE OF INSPECTION

1. the undersigned, holding a vaFid commission issued by the National Board of Bodter and Pressure Vessel Inspectors and the State or Province of California and employed by Hartford Steam Boiler lnsp. & Insur. Co.

of Connectic have inspected the pump, or valve, described in this Data Report on

  • 3 l .and state that to the best of my knowledge and belief, the Certificate Holder has con-structed this pump, or valve, in accordance with the ASME Code. Section Ill, Division 1.

By signing this certificate, neither the inspector nor hIs employer makes any warranty, expressed or implied. concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal ikqury or property damage or a loss of any kind arising from or connected with this inspection.

Date4j2wjLtf Signed 1441om4nissions l

(Authorized Inspector- INl. Bd. tend. endorsementz) and state rc gwov. and no.

I1) For mtanually operated valves only.

FORM '/z-ADM-080 1.F02 REV 2 RTL # A4.414-A Form No. 1710 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY

'As Required by the Provisions of the ASME Code Section Xl

1. Owner F.E.N.O.C.  :  : Date 01/131 2005 76 South Main Street - Akron, OH 44308 Sheet I .of 2 (ADDRESS)
2. Plant Beaver Vallev Power Station -- Unit No. 1 Route 168 - Shinninanort, PA 15077 Order #200070072
  • (ADORESS) I. Repa.r(Replacmnol Orgarizabon P.O. No., Jc No. etc 3;. Work Performed By FENOC-Maintenance Type Code Syrnbol Stamp N/A (NAME)

Route 168- Shipoinaport, PA 15077 Authorization No. NiA (ADDRESSJ Expiration Date N/A

4. Identification of System Main Steam (Q2)
5. (a) Applicable Constbcon Code 831.1 1967 Edition, S71 Addenda. N/ACode Case (b) Appicable Edition of Section Xi Utiized for Repair/RFplacement Activity. 1989 (c) Applicable Secton )a Code Case(s): N:A
6. Identification of Components

- -orrded. ASME Removed. COde Nnmeof Nwm of Manuricture ' N4sioal Board Other Yea or Se"d Co-9p00 Mtau Sniaw No N4o. ldcoexiCUo Suil Inufled (Yusor No)

Nozzle Check Enertech 11075 N/A I MS-20 2001 Removed yes Nozzle Check Enertech 10550 N/A IMS-20 1997 Installed Yes

7. Description of Work Replaced valve and inleiloutlet flange studs and nuts.
8. Tests Conducted: Hydrostatic' 5 Pneumatic- 5 Nominal Operating Pressure' Exempt 5 Other O Pressure psi Test Temp. OF
  • Recoxd $eV pesswe and kapeafwe

FORM 'A-ADM-0801.F02 REV 2 ATL # A.414-A FORM NIS-2 (Back)

9. Remarks Code Data Report attached. Previous NIS-2 Data Report Nos: 1442. 951. 883. 760, 269.

ApplNe Uamdacxers Oda Reqx b be aftad~ed and 159. Valves were supplied as ASME Section III 197f E-S72A but are installed in a B31.1 system. New 3/4" studs: Ht. #P127. nuts: Ht. #F864. Valve serial number 10550 had the disc replaced ner P.O. #55100560. new disc Heat Code KUJ-3488.

CERTIFICATE OF COMPLIANCE

! certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code.Section XI. .

Type Code Symbol Stamp. NIA Certificate of Authorization No. NIA Expiration Date N/A Signed 4 6m~w iAl Date January 24 20 05

- Oafr or OmRs DeWgees Tie -

CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components desczibed in this Owner's Report during the period A v -- 9'3 to .L J A . andstatethattothe best of my knowledge and belief. the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

2/

Azt Commissions Am, S p-3 RI h3_

(.VICizucwtHCA& ( Aut _-dr mv t *>* v I

NO. 6436 P.-10 JUN. 23. 2004 11:33AM DSESSER-YALVE FORM l-1 ( BACK-Pg. 2 of 2 -)

Certificate olders Serial No. By-89644

.I CERTIFICATE OF INSPECTION 1.the undersigned. holdln a valid conmission issued by the Natonal 8oard of Pressure Vessel tnspec'rs and ;he State or Province of LOUISIANA and employed by HSB CT of HARTFORD. CT. have inspected Vhe valve described inthis Data Report nc and state that to te best of my knowledge andbelief, the Certificate Holder has constructed is vaJeq inaccordance wilh ite ASME Code. Section 1tI.Division 1.

By signing tfis cerlilicate. leither the inspector nor his eniployer makes any warranty, expressed or implied. concernng the component desoibed in UIis Data Repbrt Furtherrnore, neither the inspector nor hWs employer shall be liable inany manner for any personal Unjuy or properly damage or a loss any kind arising fro nnected vith this inspec"o-.

Date ?4 //Sigped Commissions 1 NU ) (Arldrm

FORM 'h-ADM-080 I.F02 REV 2 RTLL#A4.414-A Form No. 1715 FORM NIS-2 OWNER'S REPORTFOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner F.E.N.O.C. . Date - 10/23/2004 .

76 South Main Street-Akron, OH 44308 - - - Sheet 1 of _ 2 ADDOS)

2. Plant Beaver Valley Power Station - Unit No. I (WJAM Shippinqport, PA 15077 0rder t200016390 (ADDRESS) Re pairRepiacemenl Orgazabwon P.O. No. Job No.. dc.
3. Work Performed By BVPS-Construction Service Type Cotde Symbol Stamp N/A (NAMED Shippingport. PA15077 Authoriz, 3tion No. NiA rII: Expiratio n Date
4. Identification of System Main Steam (Q2)
5. (a) Applicable Construction Code Section III - 1968 Edition. NIA Addenda. N/A Code Case (b) Applicable Edition of Section XiUtilized for RepairlReplacement Activity - 1989 (c) Applicable Section Xl Code Case(s)- NA: .
6. Identification of Components Cofferece ASME Remove. -cod Nameof Nam of manuacltev Naijiu boad Other Yew or Stamped Cog%e M turer seria)No No. ldvMcason BuM iall.ed (Yes of No)

SV-IMS-104C Dresser BM.07767 N/A Safety Valve 1968 Removed Yes SV-IMS-104C DresserFlow BY-89645 N/A Safety Valve 2003 Installed Yes Control

...... , ,.. .. -. . .........- v . . .

7. Description of Work Replaced valve and inlet studs/nuts.
8. Tests Conducted: Hydrostatic C] Pneumatic* El Nominal Operating Pressure 0 Exempt El Other C] Pressure _ _ psi Test Temp. OF
  • Recod test pressure and werperture

- ^ ^

FORM YA-ADM-0801 .F02 REV 2 RTL N A4A14-A FORM NIS-2 (Back)

9. Remarks Code Data Report attached. Also replaced inlet 1-3/8' studs (Ht Nos:8993360/QZC.

Apsate MyiacduWs Data Repots to be atd 13853-C625, S339,S339, and 13853-D623) and nuts (Ht Nos: K623, 73265-32-2-RXQ, 96582-TTG) all supplied by Nova Machine.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code. Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date NIA Signed W; (;f -- Date November 16 20 04 Omer or Owners Designee. rTe CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 4 6 - O3 to // -/ 7 - ° , and state that to the best of my knowledge and berief. the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Ownes Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

A-ail J. isgry s 5inture Commissions go 0J Nanti lokw. StHte. Pruwm and Endorseents Date //. /7- .,20 O M

17 ~,~

I IFORM NV-1 CERTIFICATE HOLDERS DATA REPORT FOR PRESSURE OR VACUUMA REUtEF VALVES' As Required by the Provisions of the ASME Code, Section 111, Division I Pg.oor 2 I

I Dresser Flow Control. Dresser bInLa. Hr/ 3225 i US Hw 167 N

1. Manufactured and'c&liuied by P.O.Pox 1430Alexandnia, Louisiana 71309-1430 _

- _ ( A"

_ea orNVcerANc_* der)

2. Manufactured for IWirst Energy CoprtinPO.Bx 111&ko, Ohio 443'09-3611 I- - tSU5S dPW6hzr
3. Loca6in of installation First Eney C o ea VaileI Power Station Unit 2 Shippingport Pennsyt ania 1577
4. Valve . 37p7RA Orifice size 16600 S4n L orNm.inlet size 6t Outef size 1f8b - 4CiA,)' -U:)  : 2
5. ASME Code, Section jl.t Division 1: 1968 :. NO A.Ajid&9 (2) NIA
  • (edIfc.7) Izc*ebgldda) - -, 1d2) ILoft Casere.)
6. Type Sprog 1110 33 100 SaL:. 2250 at

. S 'lX 1. fdbiur(

.1) t~esAsWei)

7. idetification E-Y-89645- WA 3NC202.. .NIA 2003
8. . Controldring settings !Lower-B Notches, Upper + 160 Notches
9. Pressure retaining itends . ...i

.e.. -. .. . .

It..... . .

Serial No. or .. . . Mati. Spe.. Ternsi I dertification Incfudinq Type or Grade .Slreng Body ADP36 ASME SA216 GR WCC, 70 ksi BonnelorYoke .ADNBI ASME SA2i6 GRWCC - 70 ksi Support Rods AD029 & AD030 ASME SA193 GR B6 110 ksi ...

Nozzle ADN91 -- ' ASME SA182GRF316 I 75ksi l

Diske ADPO8 ASTM A565 GR61 6 WA Spring Washers Adjusting Screws Spindle

-I Spnng Boling.

-Other Items Ybke Rod NRit HT #RH99 ASME SAll94 GR 2H NIA

10. Relieving capacity 873.601 LbIHr Steam @ 72 overpressure as certified by-the National Board 10-13-1967 I psi) (de)
11. Remarks:

-I 7

- I CERTIFICATION OF DESIGI N1 Design Speciication cerilfied b Louis P. C6pian .. P.E. Sale Califrtia -Reg. no. W60Q .

Design Report cerlified by d. K Sham.a .E. State Louisiana - Reg. no: 20244 CERTIFICATEOFCCOLMPLIANCE .

We certify (hat the statements ti ade hi this report are correct and that this valve conforms to the rules for construction of the ASME Code.

Section III, DWson 1.

NY Certificate of Authorization N 1747 Expires 5/20204 -

Date . IName . lrs I

. 4l0 q . 'SEE LINE I -.. . __. Sned 4 w C4650%mis) (kftftedi%=t1Wve)

I .

  • Sup ki en aWorn ucrw ;.Sn thera ,b iybeu c rm~~ f b k~ f . ' I~
-. . - issSst wdars ybudw ed'li;sr,4 " ' - ,

- I I I

FORMrAV1 (BACK-* Pg. 2 of 2 )

Certficate Niolder's Serial No. By-89645 4

CERTIFICATE OF INSPECTION 1,the undesigned, holdin aValid corrurission issued by the NationalBoard of Pressure Vessel Inspectors and the Slate or Prvince of LOUISIANA I and employed by HSB CT of HARTFORD. CT. have inspected the valve descnbed inthis Data Report on sh72 .and plate that lo e bestof myknowledge andberef, the CetilcateHolderhas constied this valve i accordance vith theAJME Code. Section lI.Wivision 1.

By signing this cerlificale,gieither the inspector nor his employer makes any wafranty expressed or implied, concerning te conponent described in hlis Data Rept. Furthermre, neither the inspetor nor his employer ha be abe inany mnief for any personal inury or properly damrage or aloss if any kind aring fro or ded 1wis nspti t ti5 Dale Sig9 d I l

<fnrAK_

(A~dNtdetbhuedorl3 Commns (N;n B.&(htd ArndmwwU)Wrd:os etA77? t vq4Md?

qe

)

-. 1 I I

I

. i 1'

V1.

FORM 'A-ADM-0801.F02 REV 2 RTL # A4.414-A Form No. 1716 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner F.E.N.O.C. . .- - Date 101231p2004 (KAME) 76 South Main Street-Akron, OH 44308 - - - - Sheet 1 of 2 (ADMRESS)
2. Plant Beaver Vallev Power Station -- - Unit No. 1 ShiDpinQcort, PA 15077 Order #200016415 (ADRESS) - . . Repai/ReawemeM Orgzabwon P.O. No.. Job No, etc.
3. Work Performed By BVPS-Construction Service Type Code Symbol Stamp N/A (NAME)

Shippinaport. PA15077 Authorization No. N/A (ADDRESS)

Expiration Date -

4. Identification of System Main Steam (Q2)
5. (a) Applicable Construction Code Section III 1968 Edition, N/A Addenda. N/A Code Case (b) Applicable Edition of Section Xl Utirzed for RepairlReplacement Activity 1989 (c) Applicable Section Xl Code Case(s): N/A
6. Identification of Components Co;r.oed. ASME Remnoed. COde Narwr NNWt of Mandactuor" NaioW Boxard Other Yew -Of San ed conqa Ua-wer serial No. No. ldcrdiftion Bai Insubed (Yes or No)

SV-IMS-105C Dresser BM-07770 N/A Safety Valve 1968 Rernoved Yes SV-IMS-105C Dresser Flow BY-89646 . .N/A Safety Valve 2003 Installed Yes Control

7. Description of Work Replaced valve and inlet studs/nuts.
8. Tests Cdriducted: Hydrostatic*e Pneumatic- I Nominal Operating Pressure g Exempt [

Other ED Pressure psi Test Temp. IF mRecrd lestgwessure and tenrperahue

FORM '/2-ADM-0801.F02 REV 2 RTL # A4.414-A FORM NIS.-2 (Back)

9. Remarks Code Data Report attached. Also replaced inlet 1-3/8" studs (Ht Nos:8993360/QZC, AHkaWe inutactees Vob Repsft a be atached 13853-C625, S339,S339. and 13853-D623) and nuts (Ht Nos: K623, 73265-32-2-RXQ. 96582-TTG) all supplied by Nova Machine.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp NIA Certificate of Authorization No. NWA Expiration Date N/A Signedd st40;Dq:i~li ate November 16 20 04

. Owner or Owes De99ree. roe a CERTIFICATE OF INSERVICE INSPECTION

1. the undersigned, holding a valid comTission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsvtvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owner's Report during the period 4-et4 03 to 11-Z7-oY. andstatethattothe best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furtherrmore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss Of any kind arising from or connected with this inspection.

/LaX 2&/ ansec-  % naur Comnissions r Z A4f t? Fq National Board. State. Prownce. and Erorse nts Date //-

  • 27 OY

,20 0

A . . . 2*I ..

FORM NV-t CERTIFICATE HOLDERS' DATA REPORT FOR PRESSURE OR VACUUM

- RELI£F VALVES*

Required by the Provisions of the ASME Code, Section 111, Division I Pg. lof 2 Dresser Flow Contol, Dresser Inc. La. Hwy 3225 @US Hwy 167 N

1. Manufactured an Ufed by P.O. Box 1430 Alexandra Louisiana 71309-1430 .
2. Mantfactured for rstEnryCorporation P.O.Box 3611 Akron, Ohio 44309-3611
3. Location of instala First EnergyCporalion Beaver Valley Power Station Unit 4 2 Shipriqpoitl Pennsyvinla. 15077
4. Valve 3 7RA Orificesize 16.00Sqln ..Nbrm.inletsize- 61 Outllsize . o'.

--- (surid o.) (k)-

hl- 1")} .-. - I'n.*.. -

5; ASNIE Code,Section II,Division 1: 1963 -NO AArtil,e 9 (A. 2) . IV2A<t

(-.licn) . . idre4adate) - idass);

6. Tye 1125 .34-101 . Sat 2250 at. 70 (9. potmpjtoicr*qb) (sdpspi1 ... '((ip'), ' \ ,*(ratla. - yhT5 pwg. Wet)
7. Identification . RY_8946. WA 3NC2022 . NIA -- 2003.-

-Ca'1 lCK4*drsstd . CR (Crn9t. I -- I(Lfd No. ti,1).

8. Conrolring setings I1Lower-B 14otches, Upp!R+ 160 Notches.
9. Pressure retaiing Hlb , .

Serial No. or Marl. Spec, Tensile Identification Including Type or Grade Strenthi Body M~LP34 ASMESA216GRWCC 70 ksi Bonnet or Yoke ADN85S ASME SA216 GRWCC 70 ks Support Rods ?D02-7 & AD028 ASME SA1 93 GR BS 110 ksi Nozzle #9DN89 ASME sA182GRF316 75 ksi

  • Dis ADP06 ASTM A565 GR 616 NIA Spring Washers Adjusring Screws spindle .

-I Spring Botting Other Dems Yok~e Rod Nut HT7 #R99 LSME SA194 GR 2)1 N/A Flanges

10. Rehein capacity *j73,601Lbflr Steam ~ . 58 owerpressure as cetfied byhe National Board 10-13-1967 I dh) fiimLarnor .btr) )
11. Remarks:

____ I ._I__ . .

I . .-

CERTIFICATION OF DESIGN Design Specification certified Lotis P..Copia . P.E. State California Reg. no. 06001

-Design Report certified by K Sharma K. . P.E. State Louisiana Reg. no. 20244 CERTIFICATEOF' COMPLIANCE We cerlfy that tie statements iade inthis report are correct 4nd that this valve conforms to the rules for constructbon of the ASME Code, Section Ill, Dvision 1.

NW Certificate of Authorization b. 1747 . Exptres 5/2a2004 Date _lq____ I Name SEE L1NE1I -, Signed . _ -

4'V9ftc"fh3*iqr (iedr raeenWa" I

.I ISuprm ntabnrm afon~inthefu4 cfItst.Skethes.ordrav~tgs " sedsrov~d-d11lx-kJL1n~vifl ,- ~ ..  ! .. -

.IA A It 0 1 . -

JuN. JUN.,,,

Li. 'vUu 10 j1:i3. .I D.ESSER-VAlVE W.09J0 F. iu FORM NV-1 (BACK- Pg.2 of 2 3 Celificate HoldesSeria!No. By-89646

. *lCERTIFICATE OF INSPECTION I.t undenrigned, holdin avald commission ssumed by the Natonal Board of Pressure Vessd t6 trst te or Province of LOUISNA and empbyed by HSB cT. . .C.

of HARTFORD, CT. 'have Inspected the valve described inNs Data Repott on . adstate and that tqite best of my knowledge andPelieL the Ceicate HI6dernas constucted this valve Inaccordaifca vtw haASME Code. SectionIJIDhiv)sin1l.

Bysig;iPbEs 'opr gNe s ernqpioyer makes iny wnrrzanetpessed or implied, coceming the cvpornpet d s in tis Data Re rtFurermore, neither the inspetOrhise oyer shal be .abbe in any man erfo any pe ainuor propertydamageorabss (anykinddarising orc w t this inspection.

Date _ 7 ed 1Cor

-A cr In. t inssis W lkS .4"/J

-p - . _

.I I

t0 I

II II

S.;

FORM %I-ADM-0801.F02REV 2 RTL #f A4.414-A -

Form No. 1722 -

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

~~
~ .f C)
1. Owner
  • F.E.N.O.C. Date 01/10/2005 (HAUE) 76 South Main Street - Akron, OH 44308 Sheet I of I
  • AODORESS)
2. Plant Beaver Valley Power St; ation - - Unit No. I (NAME)
  • Shipprinport, PA 15077 Order #200074185 (ADORESS) RqmRxeamonr Otaivzani P.O. No.. Job No, etc.

.3. Work Performed By FENOC-Construction Serv. Type. Code Symbol Stamp NIA

. ., )

Shippingport. PA 15077. Authorization No. NIA (ADORESS)

Expiration Date

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code B31.1 --- - 196 Ediion. S71 Addenda, -Code Case (b) Applicable Edition of Section l Utirzed for ReparrlReplacement Activity 1989 (c) AppricableSectionXlCodeCase(s):.N/A:
6. Identification of Components )
  • .CoeCded. ASME Rens~od, COde Nune of Nam ot Macnfxir . oal Doward o..er w or swed MaNWfacuffer Srhl oN NO. - IdMtifiCin sa tustklled (Yes or No)

Expansion Joint Garlock N/A N/A REJ-IRW-25A .1995 Renoved - No Expansion Joint Garlock NIA . . N/A REJ-I RW-25A :2004 Installed No

7. Description of Work Renlaced rubber expjrision ioint.- studs and nuts. -
8. Tests Conducted: Hydrostatic*-j Pneumatic* 0 Nominal Operating Pressure S Exempt 0 Other [] Pressure psi Test Temp. ____ F

'Recod lest presswe ad lefreelure

FORM Yz-ADNI-0801.F02 REV 2 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 656. *Year installed.

Aprcicable Maniuadwers Daa Repofs to be attadced Replacement 1-1/4 NPT studs HL Nos: K339, J662: nuts Ht. Nos: A201, 68395-FSD.

CERTIFICATE OF COMPLIANCE

'1 I certify that the statements made in the report are correct and that his conforms to the requirements of the ASME Code, Section Xl. N Type Code Symbol Stamp NIA Certificate of Authorization No. NIA Expiration Date NIA Signedig .: Inaosroe role- n -J . Date January. 10 20 05 owrw or Ownrs oes*gyee CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A9 and employed by &gd Crof H44rACK -e 5 C < . have inspected the components described in this Owner's Report during the period  : ' 9'3 to /-/oL f -, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's. ReporL Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

.,, C) -/ 5od Commissitns i,n t /. . and E mts 500sSgnatwe Naticonad8"wad. State. Provimce. andt Erdorsents Date /-/20 20 O_-

FORM 'A-ADM-0801.F02 REV 2 RTL # A4.414-A Form No. 1723

  • FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY 'Si)

As Required by the Provisions of the ASME Code Section Xi

f. I . . -
1. Owner F.E.N.O.C. Date 01/10/2005 76 South Main Street - Akron, OH 44308 Sheet 1 of I (AOORESS)
2. Plant Beaver Valley Power Staiion -- -- Unit No. I PPME)  ;

I.. ,:  : ,

Shinninnnnrt PA 15077 Order #200014525 (ADORESS) Repai acemTnt Orgatizadon P.O. No, Job No, etc.

3. Work Performed By FENOC-Construction Serv. Type.Code Symbol Stamp N/A (NAM)

Shippincport, PA 15077 _ Authorization No. - N/A

.ADORESS)

- Expiration Date I :_ .4.. - .. ... I- .

4. Identification of System . River Water (Q3)  ::. t..., . . . . .,.

i . , - .1. -

. 1  :

5. (a) Applicable Constniction Code 931 1967 Edition. S71 Addenda, -Code Case . -Z. . .

(b) Applicable Edition of Section Xi Utilized for Repair/Replacement Activity 1989 (c) 'Applicable Section XI Code Case(s): N -, --

6. Identification of Components 3

FcflWred. Cd Nwwot Narre of rMkwfwu Xmbral Board . r Yew or e Cco, Mnufrtar S"al No. No. INirkas0 Bukile lrtalled (Yes or No)

Expansion Joint Garlock N/A -N/A. REJ-IRW-25B 1995 Removed No Expansion Joint Garlock N/A N/A REJ- I RW-25B 2004 Installed No

7. Description of Work Replaced rubber expansion ioint. studs and nuts.
8. Tests Conducted: Hydrostatic* [] Pneumatic [I Nominal Operating Pressure N Exempt El Other D Pressure psi Test Temp.
  • F

'Recd WsApressure and ierrerakae

FORM '/-ADM-080 .F02 REV 2 RTL ItA4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 729. 'Year installed.

Apipatae Maniaducrer's Da Rtepos to be antaced Replacement 1-114' NPT Studs Ht. Nos: K339: Nuts Ht. Nos: 68395-FSD.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl. '

Type Code Symbol Stamp NIA Certificate of Authorization No. NIA Expiration Date N/A SignedjwQ  % . oI l lj4/A Date Januarv- 10 ,. 20 05 on O.rwes rpee, Talb I-I b {

CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of G and employed byl/A 6S C-7of l1. -e LT C , have inspected the components described in this Owner's Report during the period yt_-2 6 - to /' /L 65 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

______________________ CommissioArs X Ad 't; .2 ?Y esiwate Nonal Board. State. Pronce. and Endorsements Date /- -20 I 20 -0 J

'I, FORM /I-ADM-080X.F02 REV 2 RTL # A4.414-A I . I .

Form No. 1724 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY .. )

As Required by the Provisions of the ASME Code Section Xi

1. Owner F.E.N.O.C. - Date 0110/2005 NAM) 76 South Main Street - Akron. OH 44308 _ I:- Sheet 1 of I (ADoRES)
2. Plant Beaver Valley Power Station ' - - - --- Unit No. I

, (A ME) I ' 'I - -' . ' .

ShippingDort, PA 15077 Order #200074189 -

  • (ADDRESS) RepaiRegac t Orgarizatin P.O. No,.Job No,. etc.
3. Work Performed By JFE 4OC-Construction Serv. Type.Code Symbol Stamp, ' NIA .- :

Shippingport. PA 15077 Authorization No. NtA (ADORES)

Expiration Date -:

4. Identification of Systqm River Water fQ3) '
5. (a) Applicable'Construction Code 831.1 -1967 Edition, S71Addenda - 'Cod Case (b) Applicable Edition of Sectian Xl Ublized for Repair/Replacement Activity _1989 (c) Approcable Seclion )XCode Case(s): NIA
6. Identification of Components CofTed.d, ASME Renewed Code Name of Na" or Mapuacar N&aiol B.Board Othe, YWar or . Stup .

Corry- - . . nura r Scrido.fNo . o. .

Idetirmeo identirkmison Baib' ts^

Inswwle ~ (Yes or.rt0 Ho)

Expansion Joint Garlock N/A .N/A REJ-I RW-27A 1995 Removed No, -

Expansion Joint Garlock N/A . N/A REJ- IRW-27A 2004 Installed No

7. Description of Work Replaced rubber expansion ioint, studs and nuts.
8. Tests Coqnducted: Hydrostatic*

Other El El Pressure Pneumatic*

'Record test pressurwe and toriperalure 0 Nominal Operating Pressure E psi Test Temp.

Exempt

  • _F El 1'.

FORM Y-ADM-080 i.F02 REV 2 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 629. Year installed.

ApWicable Marcacturer'sData Peporto to be altached Renlacement 1-1/4" NPT Studs HI. Nos: J662: Nuts Ht. Nos: FSD. 68395-FSD.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that tqlis conforris to the requirements of the ASME Code, Section Xl.

I Type Code Symbol Stamp NJA Certificate of Authorization No. N/A Expiration Date NIA Signed 1, iuh;1:, *W 4 j A* Date 0~.30 IJO .Y 3' 20 05

~ ~ ~.

. 6c- O,? wmes Designee, rae r 0%

t I

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Bolter and Pressure Vessel Inspectors and the State or Province of XaL4 and employed by. 1gfd C7 of f,/erzao A- d,, c '7, have inspected the components described in this Owner's Report during the period 9'0 -9( 3 to /-/ -?-- ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ADS_~ de 7edoCwe Commissiops <v A, 9

/ A oL? 1C Nation Board. State. Proance. and Endorsefflnts Date /-/I d 220 Jhos

V, I FORM 'A-ADM-0801.F02 REV 2 RTL IVA4.414-A Form No. 1725 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner' ' F.E.N.O.C. - -. -- .- Date 01/13/2005 (NA) 76 South Main Street - Akron. OH 44308 ' - ' \ Sheet I of 2 (ADRESSM).
2. Plant Beaver Vallev Power Station Unit No. 1 (N JeQ . , ,, ".

Route 168 - ShiDninaoort. PA 15077 Order #200070163 (ADDRESS) spoirleracyeme Orgarizabon P.O. No_ Job No, etc.

3. Work Performed By FENOC-Maintenance Type Code Symbol Stamp N/A (NAME) A Route 168 - Shivoingport, PA 15077 Authorization No. N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Main Steam (02)
5. (a) ApplicableConstructionCode 831.1 1967 Edition, S71 Addenda. N/A Code Case (b) Applicable Edition of Section Xl Utilized for RepairlReplacement Activity 1989 (c) Applicable Section Xl Code Case(s): WA
6. Identification of Components CO..d.C. ASME Remnved, - Codc Narcof Nmm of Maraclwr National Dowt Ott Yew of S-aied C ry n a u SerialNo NO, ldodrKWaswn Duak Idascd (Yes or N)

Nozzle Check Enertech 10548 NIA IMS-18 .1997 Removed Yes Nozzle Check Enertech 11236 N/A IMS-18 2002 Installed Yes

7. Description of Work ' Replaced valve and inletloutlet flange studs and nuts.
8. Tests Conducted: Hydrostatic* [] Pneumatic* El Nominal Operating Pressure 0 Exempt El Other [] Pressure psi Test Temp. °F Recod lestpresswe an ten~erature

FORM Ai-ADM-0801.F02 REV 2 RTL HA4.414-A FORM NIS-2 (Back)

9. Remarks Code Data Report attached. Previous NIS-2 Data Report Nos: 953. 842. 600. 498. 311.

Appfafe Uantiactwers Dota Repots b be atadced 264. and 142. Valves were supplied as ASME Section 1111971 E-S'72A but are installed in a B31.1 system. New 3/4" NPT studs: Ht. #F863 and P127. Valve serial number 11236 disc was replaced by Enertech under Purchase Order 55100560. new disc Ht. Code KUJ-61 11. year built-2003.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp NIA Certificate of Authorization No. N/A Expiration Date NIA Signed *k°JJ) 4r) IT Date February 1 20 05 CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owner's Report during the period 4-A- 0- / 3 to oZ- /-P. *and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commislions ADZ= 4.

State. Proance, and Endorsemwts Date CX --/2 , 20 K-

I FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code, Section 11.Division 1 Pog.lof 2

1. Manufactured and certified by Enertech, A Div. of Curtiss-Wright Flow Control Corp., 2950 Birch St.. Brea, CA 92821

.(name and address of N Certiricat HolderI

2. Manufactured for First Energy Corp.; P.O. Box 361 1; Akron, OH 44309-3611

- . name and address of Purchased

3. Iocat~on'of installation - Beaver Valley Power Station; Route 168; Shippingport, PA 15077 (name and address)
4. Model No.. Series No.. or Type DRV-Z Drawing PD98401 Rev. F CRN None
5. ASME Code.Section III, Division 1: 1971 S72 3 - None

.edition) (addenda datel Iclass) (Code Case ro.)

6. Pump or valve Nozzle Check Valve Nominalinlt 'i ' Outlet size (in.) fin.)
7. Material: Body SA-1 05 Onnet NIA. Osk SA479 Type 316 Boting N/A (a) lb) _ Ic) Id) le)

Cert. Nat'l Body Bonnet Disk Holder's Board Serial Serial Serial Serial No. No. No. No. No.

11236 None KLT-001 None JZE-003 I - . 1. , I I I I

, , :1. . I I. - I .1 I : I , .1 - , I I I

-  : I ;, - . -- I. ,

7 - -

3 - -I,--- , ,

.~ . . .. ,.

  • Suppienmental information In form of liss. sketches. or'drawings may be used provided I1) size is 83 x 11.12) information in items 1 through 4 on ths Data Reportn Is ciuded on each sheet. 31 each sheet is numbered and the number of sheets ksecorded at the top of this torm.

(12188) This form (E00037) may be obtained from the Order Dept.. ASME. 22 Law Drive. Box 2300. Fairfield. NJ 07007-2300. REPMNT 693

'I FORM NPV-1 IBack -. Pg. 2of 2 )

cetificate Holder's Serial No. 11236

8. Design conditions - 1100 ,, 560 _OF or valve pressure class 600 '4'

-v I,,

(prewrel hrttefpefature)

9. Cold working pressuree_ 1440: psi at 100 0 F IO. Hydrostatic test 2175 psi. Disk rinfarentiai test pressure 1600 psi
11. Remarks: Qty 1. Enertech Job Number 28199V CERTIFICATION OF DESIGN Design Spepiotcation certified by raJ . an P.EF State CA Reg. W.o 23241 Design Report certified by Ira J. Silvenrman P..Sae CA Reg. nao. 23241

.. CERTIFICATE OF COMPUAiNCE We certify that the statements made In this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code. Section IlIl, Division 1.

N Certificate of Authorization No N-2826 Exwirps 10/11/05 Date Z//_*/, -Name ErtOiOADiv. 01QursWdrbwCo,*olo Signed .

IN Cartifiate "older) lauthorized represetiative)

CERTIFICATE OF INSPECTION

1. the undersigned. holding a valid comrnission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California and employed by HSB CT of Connecticut have inspected the pump, or valve. describod in this Data Report on
  • L o2 O/, and state that to the best of my knowledge and belief, the Certificate Holder has con-structed this pump. or valve, In accordance with the ASME Code. Section ill. Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied. conceming the component described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date I,- 2-4ned - Commissions / J (Authodzed Inst INItI. Bd. Und. endoftserents) and state or ptoV. aid no.l (1) For manually'operate~d valves only.

I . . --

I FORM Vz-ADM-080 .F02 REV 2 RTL # A4.414-A -

Form No. 1726 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the'Provisionrs of the ASME Code Section Xi

.~~~ I ....

1. Owner 'F.E.N.O.C. i- Date 01113/2005 (NM) 76 South Main Street - Akron, OH 44308 I _ Sheet . 1 of 1 (ADORESS)
2. Plant Beaver Valley Power Station - - .Unit No. I (NAME)

Route 168- Shioina.ort. PA 15077 Order #200065000 (AD:RESS) Repai/Re racwient Organizatn P.O. No.. Job No, etc.

3. Work Performed By FENOC-Maintenance Tye Code Symbol Stamp N/A

.(NAME)

Route 168- Shippinqporl, PA i15077 Authorization No. N/A (AlDRESS)

., I,  ;- Expiration Date N/A

4. Identification of System Main Steamn (02)

-. 5. (a) Applicable Construction Code ANSI B16.5/16.34 1973 Edition. NAAddenda. N/A Code Case (b) Applicable Edition of Section I Utilzed for RepairlReplacenent Activity 1989 (c) Applicable Section xl Code Case(s): NWA

6. Identification of Components

... . Ceroed ASME Namro of Na of ufacturr. NahonUl Boad Other Year or Sa-Ted Cmp% i mrfacog Se No, NoNo.

.idmiricaaor, io. . instlld -: (Yes o No)

Check Valve Crane N/A N/A IMS-80 1976 Corrected No Hinge PinPlug CraneNuclear N/A N/A N/A 2004 Installed No

7. Description of Work Replaced and seal welded hinge pin lug. - Replaced cover studs and nuts. Excavated and repair welded linear indication associated with seal weld.
8. Tests Conducted: Hydrostatic El Pneumatic D Nominal Operating Pressure 3 Exempt E Other Pressure _ _ psi Test Temp. _ _ F

'Reccrd test pressure and Lnperarire

FORM 'A-ADM-080 .F02 REV 2 RTL # A4.41I4-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Previous NIS-2 Data Report Nos: 1557. 1406. 1209, 1018 Appcawe U Data Reports to be aftadd sufachrees 843, 601 and 144. *year installed. New 5/8a NPT Cover studs: Ht #M796, nuts: Ht. #M797.

Repair in valve body was  %' from the toe of the hinge pin plug seal weld. Excavation was approx. .250" deep prior to weld repair.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code. Section Xi. v Type Code Symbol Stamp NIA Certificate of Authorization No. NIA Expiration Date N/A Signed'g ed r 5-a-4L- Date January 13 I 20 05 Owner o Owners Desru~e. rTe CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid comrnmission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owner's Report during the period 1-2 (- - 13 to /-/ I Em5 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or irnplied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ __ _commissions Z A'e kpedtWSopakre t Hboml BoaldL SUae. Prowxpe and Endors&Twft Date /,/C2/0 ,, 20 A-

I -^

FORM V2-ADM-0801.F02 REV 2 . . RTL # A4A414-A Form No. 1727 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner F.E.N.O.C. Date 01/13/2005 76 South Main Street - Akron. OH 44308 Sheet 1 . of I

{ADURE=)

2. Plant Beaver Vallev Power Station Unit No. 1 MAE)

Route 168 - ShinoinOnort. PA 15077 Order #200065001 tADOFWSS) rFepawRelace mle rqzwzabm P.O. No, Job No.. Mr

3. Work Performed By FENOG-Maintenance Tope Code Symbol Stamp N/A .

BNME)

N.

Route 168-Shipping ort, PA 15077 Authorization No. N/A HADESS)

Expiration Date N/A

4. Identification of System Main Steam (Q2)
5. (a) Applicable Construction Code ANSI 616.5/16.34 i973 Edition. N/AAddenda. N/A Code Case (b) Appricable Edition of Section Xl Utiized for Repair/Replacement Actvity 1989 (c) Appricable Section Xl Code Case(s): NLA
6. Identification of Components

.. .' . Corecd. ASME Removed. Cb&

Nameof N.m Of mam-iaw er Nt ona 80d other C or Stamped CDonyoncaE Mwaacuu Saul No, No. IdarKici on BuW imstaled (Ys or No)

Check Valve Crane' N/A N/A lMS-81 1976 Corrected No Hinge Pin Plug Crane Nuclear N/A NIA N/A 2004 Installed No

7. Description of Work Replaced and seal welded two hinge pin Plugs. Replaced cover studs and nuts. Excavated and repair welded linear indication associated with seal weld.
8. Tests Conducted: Hydrostatic El Pneumatic D Nominal Operating Pressure 3 Exempt El Other El Pressure psi Test Temp. OF

'Pcord test pressure and teicture

.E FORM A-ADM-080 I .F02 REV 2 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Previous NIS-2 Data RePort Nos: 1558. 1407. 1210. 1158 Akable mauiackvees Data Raepof to be afnached 997. 907. 844. 665. 537 and 168. year installed. New 5/8" NPT Cover studs: Ht. #M796. nuts: Ht.
  1. M797. Repair in valve body was %" from the toe of the hinge pin plug seal weld. Excavation was approx. .250' deep orior to weld repair.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp WNA Certificate of Authorization No. N/A Expiration Date NIA Signed pis tS 4 Date January 13 20 05 Onw or s s ro e IFe CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owner's Report during the period et AI I3

-- to /- A / - O/, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xa.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owner's Report Furthermore. neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

.&2, / Commissions Goo; krt Slgnalure srJu> Wood. State. ProAnce. and Endosemts Date 20 H Date 207

'i .

FORM VA-ADM-0801.F02 REV 2 .. . RTL N MA 14-A

-Form No. 1728 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

. , , ,- _Z .

1. Owner - F.E.N.O.C. Date 01/13/2005 76 South Main Street-Akron. OH 44308 - -Sheet I of.: 1I ADOR)
2. Plant Beaver Valley Power Station Unit No. I o h t .. .e6- .. _P, .' .

Route 168 - Shiwi~narport. PA 15077 Order #200065002 (ADORESS) , Repufshaceme Orgaffbon P0. No. Job No. etc.

3. WorkPerformed By FENOC-Maintenance Type Code Symbol.Stamp N/A Route 168 - Shippingport, PA 15077 Authorization No. N/A (ADORE5S)

,Expiration Date N/A

4. Identification of System Main Steam (02)
5. (a) Applicable Consucion Code ANSI816.5/16.34 1973 Edition. 'N/A Addenda. N/A Code Case (b) Applicable Edition of Section )i Utilized for Repair/Replacement Activityb 1989 (c) Applicable Section Xl Code Case(s): WA , -
6. Identification of Components Co:ctc . ASME

" .eosd. COd&

Nameof NAd facsxr .. -Ns Board ober Yew or Som~ d C.Vic mawfactarer SnilNo. N. . &fitfiegsoa Buik Instald (Yes w No)

Check Valve Crane N/A N/A , IMS-82 1976 Corrected No Hinge Pin Plug Crane Nuclear N/A N/A' Lot #14K 2004 installed No

7. Description of Work Replaced and seal welded hince pin Mlua. Reolaced cover studs and nuts. 7t Excavated and repair welded linear indication associated with seal weld.
8. Tests Conducted: Hydrostatic* [] Pneumatic El Nominal Operating Pressure 3 Exempt El Other a] Pressure psi Test Temp. _ _ F

'Recod leA pressure wad Iepee

FORM 'A-ADM-0801F02 REV 2 RTL UA4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Previous NIS-2 Data Report Nos: 1559, 1408. 1211. 1019 Approve Maradwues Data Ri 1lt be ztladed 845. 666. and 148. *Year installed. New 5/8" NPT Cover studs: Ht. #M796. nuts: Ht. #M797.

Repair in valve body was at the toe of the hinge Din plug seal weld. Excavation was approx. .125" deep.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.  %

Type Code Symbol Stamp NIA Certificate of Authorization No. N/A Expiration Date N/A Signed G od 6P LT Date January 13 20 05 ror Overs Desine. rue I CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of.

Hartford. CT have inspected the components described in this Owners Report during the period (o- 6l3 (aw2 to /- ______* and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions oz 2 6 z. .

99~attte f Natbnat Bo3wd. : Rte.

Prwnce, and Erdffints Date .,*-2 20

FORM %-ADM-080I.F02 REV 2 RTle # A4.414-A Form' No. 1735

! ' .,I I-FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY.

- - As Required by the Provisions of the ASME Code Section XI

.1. Owner r. Firt'Enerav Coro Date November 10, 2004 (NAME) -

76 South Main Street. Akron. OH 44308 Sheet 1 of __ 2 (ADDRESS)

2. Plant Beaver Valley Power Station . 'I Unit No.' I (NAE)

Shippingport, PA 15077 I.. . .20001 56271 (ADDRESS) Repair/Reo4aceniwt Orgariaslon P.O. N4o,Job No.,*ot.

3. Work Performed By . FENOC - Construct ion Type Code Symbol Stamp ' VAA

, (NAME)

Shippingport, PA 15077 _ _-

_ . _ Authorization No. * . N/A

- - (ADORESS) ' -

Expiration Date NIA

4. Identification of Systemr Feedwater. BV-l-24-Svstem (02)'
5. -(a). Applicable Construction Code ASME Ill Class 2 1971 '.Edition, W 1972 Addenda, - Code Case (b) Applicable Edition ofSection Xl Utilized for Repair/Replacement Activity 1989 (c) Applicable Section XI Code Case(s) N416-2
6. Identification of Components i .1 CorTed. ASME Code eor 'amN or MGa wer Otbr Ye e."Nal Of. or  : Sumped-Coponema. Ma&M kWUr Srial No . Bond, ldct ir';am Bunk . ,.lled. (Yes r No)

NO.

HYV-IFW- FLOWSERVE AU201 - 2002 INSTALLED NO IG 1=A Flowserve - Edward Vogt Valve Co.

7. Description of Work Installation of fast acting feedwater isolation valves (FWIVs) into the feedwater lines upstream of containment isolation check valves.
8. Tests Conducted: Hydrostatica Pneumatic* Nominal Operating Pressure d Exempt El Other E] Pressure Normal psi TestTemp. Normal 'F

'Reard ostpressure amd kmerafse FORM 'A-ADM-080 1.F02 REV 2 RTL 1A4.414-A

FORM NIS-2 (Back)

9. Remarks No code data report available I Acable Maads Data Reports to be atadwed CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date NIA Signed

  • Oar aQW3 UWrr

, A9 I_,

dOS9deo. FMI d/M/fFt Date )0 .. u_ 20 _ _

CERTIFICATE OF INSERVICE INSPECTION

1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of P e and employed by f'J' c.T of le-4dc, o we C-have inspected the components described in this Owners Report'during the period V--2 t' -O3 to A ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

7

. A- J 'f /Dt3 'Z 9-V

_ _ _ jZ _ . _ __h Commissions , PJ National Board, Sate. Provinm and Endorsenwts Date />, -( 20 0 e_

FORM /z-ADM.0801.F02 REV 2 RTL 0 A4.4 14-A Form No. 1736

'FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTMTY As Required by the Provisions of the ASME Code Section Xl

1. Owner First Energy Corn Date November 10, 2004 (NUME) 76 South Main Street Akron, OH 44308 Sheet 1 of 2 (A{ fESs)

B av e r V E P . . . . . . .

2. Plant Beaver Vallev Power Station Unit No. 1 (NwAE)

Shippingport, PA 15077 * -. 200015586. .

(ADORESS) Repaiiwepace Oiarazbon P.O. Nox.Job No., dc

3. Work Performed By 'FENOC - Construction Z. .Type Code Symbol Stamp . N/A (NAME)

Shippingport, PA 15077 Authorization No. N/A -

(ADORESS).

ExpirationDate N/A

4. Identification of System ' Feedwater. BV-1-24-System (02):
5. (a) ApplicableConstructionCode ASMEIlIClass2 1971 - Edition. W 1972 Addenda. - Code Case (b) Appricable Edition of SectionXI Utirized for Repair/Replacement Actvity 1989 (c) Applicabl Section Xl Code Case(s) N-416-2
6. Identification of Components , . .

Coffetedd ASNE Removed. Code Nme o- . Name or Mamifacomer N9;WW Od- Yew . S.mped CW Ma _rfi NO. Bo: d ldedaiaf- t . luzed . (Y- or M) 1-TerNo.

HYW-IFW- FLOWSERVE AU202 - 2002 INSTALLED NO I OOB Flowserve - Edward Vogt Valve Co.

7. Description of Work Installation of fasi actinq feedwater isolation valves (FWIVs) into the feedwater lines upstream of containment isolation check valve's.
8. Tests Conducted: ,Hydrostatic* EJ Pneumatic* 0 Nominal Operating Pressure g Exempt O

. Other El Pressure Normal psi Test Temp. Normal °F

  • recordWestprossmre mdtenieratze FORM '2-ADM-080 1.F02 REV 2 RTL # A4.414-A

FORM NIS-2 (Back)

9. Remarks No code data report available Wa4prbIe Mwi~.ras O.a Row tos rbe ahedA CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A I Signed Ai I

rvOwne

- Alidd-A"1%0-,

wor~ OAn O& eoe . v

>Date 146dt Iw . I

_. 20 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of /4 and employed by //Ji C Woof ,T94

- q d, c-t.

have inspected the components described in this Owners Report during the period yV-z (a - 03 to /-X _ C! ^ O .. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owneres Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

.J1011-1/ 1--z eie's ightabX Commissions Hi ,J 'A. 0 L,3 r Natnt Soxd, State. Province, and Erhorwts Date /,z -(-

FORM %-ADM-0801.FO2 REV 2 RTL #AA4.44-A Form No. 1737 FORM NIS-2 OWNER'S REPORT-FOR REPAIRSIREPLACEMENT ACTIVITY

- As Required by the Provisions of the ASME Code Section XI

1. Owner First Energy Corp Date November 10, 2004 76 South Main Streel, Akron. OH 44308 Sheet I of 2 (ADORESS)
2. Plant Beaver Valley Power Station. Unit No. 1

{NAW)

Shippingport, PA 15077.  : 200015457 (ADORESS) Repa-IRepLiemrtt Orgwiza P.O. No, Jab No.. etc.

.3. Work Performed By FENOC - Conitruction ,-TypeCodeSymbolStamp ' N/A.

(NAMEX Shippingport, PA 15077 .. Authorization No. N/A (ADORESS) -

Expiration Date N/A

  • 4. identification of System Feedwater. BV-1-24-Svstem (02)

.5. (a) AppricableConstructionCode ASMEIIIClass2 1971 -_Edition, W 1972 Addenda. - Code Case .

(b) Applicable Edition of Section XI Utiized for Repair/Replacernent Activity 1989 (c) Applicable Section Xl Code Case(s) N-416-2

6. Identification of Components Qoeraed. ASME Rem.Ved. CO&e

. or

.an N of Mamwfadurer Nit-e Othff Year O. Smaped Compae MAUradure SerikI No. Board Ideseirwcatn . auiktale (Y-a Or No).

'No.

HYV-IFW- . FLOWSERVE Au2o3 - 2002 INSTALLED NO I 00C ' , ' - ,

Flowserve - Edward Vogt Valve Co.

7. Description of Work Installation of fast actirinf6edwater isolation valves (FWIVs) into the feedwater lines upstream of containment isolation check valves.
8. Tests Conducted: Hydrostatic' El Pneumatic El Nominal Operating Pressure 0 Exempt E3 Other E] Pressure Normal psi Test Temp. Normal OF FRed test presste and tlerpwthwe FORM Vz-ADM-0801.F02 REV2 RTL # A4.414-A

FORM NIS-2. (Back)

9. Remarks No code data renort available
  • iie Marhcewus DataRenp W be affadad CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A '

Certificate of Authorization No. NIA Expirat ion Date NIA Rinned A I .*

&ref am4l-,

_ ,n SD ,NTe As A _ Date -

/2-16/dyE f -f ,

20 CERTiFICATE OF INSERVICE WNSPECTION

1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of .. A? and employed by 1A<d C7 rof 0

//A Trt e d, C 7.

have inspected the components descibed in this Owners Report during theperiod 4/ °3 0; to / ' .and sate that to the best of my knowledge and belief, the Owner has performWd examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or irnplled, concerning the examinations and corrective measures described in this Owner's Repbrt. Furthernore, neither the inspector nor his employer shal be liable in any manner for any personal injury or property damage or a loss of any kind arisingfrom or connected with this inspection.

Al-l '/ Commissions . -T" ^/ .I

-.30

.1.4 NatinJi doadState. PNavice. a

( 38W" Endorserents f

Date /.2 , 20 °OS at,'

FORM '%-ADM-O801.F02 REV 2 RTL # A4.414-A Form No. 1740 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C. Date 12115/2004 (NAME}

76 South Main Street - Akron, OH 44308 Sheet 1 of I (ADDRESS).

2. Plant Beaver Vallev Power Station Unit No. I RoEu1 6)8 - Sh i n aI. PA 1 I -7

-0,7 Route 168 - Shinninanort- PA 15077 Order # 200059462 (ADDRESS) RepariLRevacemnt Orga3rzabwon P.O. No, Jcb No., etc

3. WrIero an. ten:c md B B P
3. Work Performed By BVPS-Maintenance 11/2eCode Symbol Stamp N/A Route 168 - Shioninanort. PA 15077 Authorization No. - NIA (ADDRESS)

I I . .  : .'

Expiration Date NIA 4.. Identification of System Reactor Coolant (Q1)

5. (a) Applicable ConstructionCode Section III 1968 Edition. S68 Addenda, N/A Code Case (b) Applicable Edition of Section XaUtilized for Repair/Replacement Activity 1989 (c) Applicable Section XI Code Case(s): NIA
6. Identification of Components Cornadd. ASME Rmived Codc Nwot Nam of Ma.flCs~ Naiona Dowd Odxx YCr or Suansmed Craonent m:a-fActwor SaWuNo. NO fdawii0a Bui Intalkd (Yes of NO)

Relief Valve Target Rock I N/A RV-IRC-551A 1995 Removed Yes Relief Valve Target Rock 5 N/A RV-IRC-551A 1973 Installed Yes

7. Description of Work Replaced valve with spare for testing purposes.
8. Tests Conducted: Hydrostatic* l Pneumatic' [ Nominal Operating Pressure 3 Exempt El Other E] Pressure psi Test Temp. OF maecordbet presswe and 9effperabme

I FORM /+/--ADM-0801.F02 REV 2 RTL # A4.4 14-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Previous NIS-2 Data Report Nos: 1255.892. Valve S/N 5 Aptcable IWvk~actx's Data Revb to be attadied was cleanedlinspected bv Wyle Laboratories under Purchase Order #7060635.

New inlet studs (12 ea):1-3/8" UNC. Ht #S339.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

. ~..

Type Code Symbol Stamp NIA Certificate of Authorization No. NIA Expiration Date NIA Signed G o-uw l r Date January 31 . 20 05 Owne o Owners Desue. Tte L J CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of. Pennsylvania and employed by HSB CT Of Hartford. CT have inspected the components described in this Owner's Report during the period 4- L - to -/- J . and stale that to the best of my knowledge and belief. the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance lAth the requirements of the ASME Code.Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or inplied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Aira0NS 2Commsions Ntoa soritte orLSae rw.a now Date , 20 _____

FORM %A-ADN11-0801.F02REV 2RL RTL #A.4A A4.414-A Form No. _ 1741 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi 1.. Owner *F.E.N.O.C. Date _ 1211512004 76 South Main Street -Akron, OH 44308 Sheet - 1 of 1 (AOORESS)

2. Plant Rn~qvnr Vallev Pnw~r S;tqtion Unit No. 1 (NAM-)-

Route 168 - Shippincport. PA 15077 Order #200027095 (ADDRESS) Repair/ReAIcement Organazabor P.O. No.. Job No_etc.

3. Work Performed By BVPS-Maintenance TypV Code Symbol Stamp N/A Rout:e 168 - Shippingport, PA 15077 - Authorization No. NIA (ADMRESS)

Expiration Date NIA

4. Identification of System Chemical and Volume Control (02)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition. S71 Addenda. N/A Code Case (b) Applicable Edition of Section Xi Utilized for Repair/Replacement Activity 1989 (c) Applicable Section Xl Code Case(s): NIA
6. Identification of Components Cogweoed. ASPME Re"'ed. COde Narneof Nanrwof mapufactwer Hlk'.at Board other year a, Stamped C-Tonioca MjUwamm~ Serial No ~ No Idceraificasmo Suat . nuallcd (Yes or NO)

Diaphragm Valvc IlTTGrinnell -- N/A .ICH-138 Corrected No 7.-Description of Work Replaced body to bonnet studs and nuts..

8. Tests Conducted: Hydrostatic a Pneumatic' [ N6minal Operating Pressure D] Exempt f Other a Pressure _ _ psi Test Temp. IF

'Record lest pressure ad teHperakwe

FORM '/z-ADM-0801F02 REV 2 RTL # A4.4 14-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. New Studs: 7/16" UNC. Nuts: 7116" UNC Ht. #J663.

Appkcate Mamsaiers Data Repoq1s to be auadced CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed f $2/r Date G14-. 20 Ay ownr at owns D oeqw~e 1de CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned. holding a valid commrission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HS8 CT of Hartford. CT have inspected the components described in this Owneres Report during the period -/3 -a to I.A-X and state that to the best of my knowledge and belief, the Owner has perforned examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section X.

By signing this certifcate neither the inspector nor his employer makes any warranty, expressed or implied, concerning tho examinations and corrective measures described in this Owner's Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

A;: -/. -- Commissins =A; Iord t. . IVs Nauseag Dowd. Sue. Prowinee and Edrseim t Date /AX-A 2 - _ .

20 1

A FORM VA-ADM-0801.F02 REV 2 RTL #A4.414-A Form No. 1743 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner F.E.N.O.C. Date 01/17/2005 (NWE) 76 South Main Street - Akron, OH 44308 Sheet I of 1 (ADDRESS)
2. Plant Beaver Valley Power Station Unit No. 1 (HAME)

Route 168 - Shipdingport, PA 15077 Order #200013659 (ADDRESS) PRepaiWReiacement Oanrizaton P.O. No. Job No- etc.

3. Work Performed By FENOC-Maintenance Tipe Code Symbol Stamp I- N/A*

Route 168 - Shioninanort. PA 15077 Authorization No. ' NIA (ADDRESS)

I - : 1.. Expiration Date N/A

4. Identification of System River Water (03)
5. (a) Applicable Construction Code B31.1- 1967 Edition. S71 Addenda. N ACode Case (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 (c) Applicable Section Xl Code Casess)y NIA -N-.- -
6. Identification of Components comded. AS.E

. ,. -anoved, CA)

Nu of Nwr o tamtw NaoaI Dowd Other Year. or Shnwed Coame Mjfaawor SaW No. No. fIdsiflcson B..kl Issutled (Yes or No).

Buterfly Valve Enertech 10296 N/A IRW-811 1994 Corrected No

7. Description of Work Replaced inletloutlet flange studs and nuts.
8. Tests Conducted: Hydrostatic* D Pneumatic* D Nominal Operating Pressure D Exempt 1*

Other a Pressure psi Test Temp. OF

'Record lest presswe and lesperalxe

FORM V.-ADM-0801.F02 REV 2 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Repo6rt available. Previous NIS-2 Data Report No. 701. Replacement Applicaue MamAbctoxees Dta tepolis lo be attadced 1" NPS Studs: Ht. # J456. Nuts: Ht. #M128.

CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code. Section Xl.

Type Code Symbol Stamp NWA Certificate of Authorization No. N/A Expiration Date N/A Signed e da > jzr ' Date January 17 20 05 OMeW Cr.0WFs rere We I CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT Of Hartford. CT have Inspected the components described in this Owner's Report during the period

  • __ 6 i____ 3 to /-/ 9 - 52f and state that to the best of my knowledge and belief, the Owner has perfomned examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code. Section XA.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the inspector nor his employer shal be riable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

'e" -L' 2, - _ Coim"sIons Nao Naton Boa" I State. Proa)ce, and Endoraen 'ts Date - - I 20 &Z_

- I

  • h FORM 'A-ADM-0801.M02 REV 2 - . RTL # A4.414-A Form No. 1744 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

. F - :  :' . - ,- .., .

1. Owner F.E.N.O.C. Date 01/17/2C005 BN E) - _..

76 South Main Street - Akron, OH 44308 Sheet 1 of_ 1 (ADDRESS}

2. Plant - Beaver Valley Power Station Unit No. 1
  • AME) I -

Roatte 168 - Shinninanort. . . PA

. 15077

. . Order #200074190.

VOORESS) Re-areptacefferu Oarizabon P.O. No, Job No, etc.

3. Work Performed By FENOC-Maintenance Tvpe Code Symbol Stamp N/A (NAMtE1 Route 168 - Shippinciport, PA 15077 Authorization No. ' N/A (ADDRESS)

Expiration Date N/A

4. Identification of System River Water (03)
5. (a) Applicable Construction Code B31.1 1967 Edition. S71 Addenda. N/ACode Case (b) Apprlcable Edition of Section XlUtilized for Repair/Replacement Activity 1989 (c) Applicable Section Xi Code Case(s): NI1A -
6. Identification of Components Corze. AS .E Nurof Nanc of . T orl Board Other Year or Soqxd CoNo 1 FmaManui uadr Sedl No. No. I dc3iificNio. Bui flaed (Yet or No)

ExpansionJointGarlock N/A .. N/IA REJ-1 RW4A I . 1995 Removed No Expansion Joint Garlock N/A N/A REJ-IRW4AI 2004 Installed No

7. Description of Work Replaced rubber expansion joint and inletfoutlet studs and nuts.
8. Tests Conducted: Hydrostatic* j Pneumatic* j Nominal Operating Pressure 3 Exempt O Other D Pressure ., psi Test Temp. _F '

'Reccord test pressure arnd kennrature

Y .

FORM /z-ADM-0801.F02 REV 2 RTL NA4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Previous NIS-2 Data RePort No. 632. *year installed.

A4pcable Uanracbxes Daf Repout 10 be allhe Replacement 1-1144 NPS Studs Ht. #J662.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and thet this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp MIA Certificate of orization No. N/A . Expiration Date NIA

_,ASignzd. *i In Ad Date January 17 , 20 05 I, 0w u or Ohs Designee. rie of CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owners Report during the period e -v 6 - 56 a to Ž- P and state that to the best o my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Ownee's Report Furthernore, neither the Inspector nor his employer shaD be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.

J9 8_ Comrnissons Depe

- 32oB S0t e, and fi A Date /-5 -,20 Als

FOM. .

FORM '/i-ADM-0801.F02 REV 2 RTL # A4.414-A Form No. _ 1745 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner - F.E.N.O.C. Date 12/16/2004 MAWE) 76 South Main Street-Akron. OH 44308 - Sheet 1 of 1 (ADDRESS)
2. Plant Beaver Valley Power Station - Unit No. 1 (NAME) ~ .

Route 168 - ShiDninafort. PA 15077 Order #200073988 (ADRESS) - Repaiw/Replacemlent OrgNzation P.O. No- Job No. etc I..

3. Work Performed By BVPS-Maintenance Typb Code Symbol Stamp NIA (NAIVE)

Route 168 - Shiopingnort, PA 15077 Authorization No. NIA (ADDRE-SS)

Expiration Date N/A

4. Identification of System Main Steam (Q2)
5. (a) Applicable Constnrction Code ANSI 8311.1- 1967 Edition. S71 Addenda. NA Code Case.

(b) Applicable Edition of Section Xi Utilized for Repair/Replacement Activity IBI (c) Applicable Section Xl Code Case(s)

6. Identification of Components Cofcded. ASME Rcmoved. Code Naar or Nare of Mamnladner NuiorW Board Other Year or samped Ccaronefa arer SNoi N. IdC.ifKcMimn Br B letalld (Yes or oM)

Governor Valve Xress-r-Rnd (Teny T38492 (Turbine)' N/A I MSA464 1976 Corrected No Stcam Turbine)

Plug Dresser-Rand N/A N/A N/A 2004 Installed No

7. Description of Work Replaced valve stem/plug assemble.
8. Tests Contducted: Hydrostatic' [] Pneumatic* [] Nominal Operating Pressure 7] Exempt N Other El Pressure - psi Test Temp. OF

-Record lest pressue and ler e ue

'-I I

FORM Yz-ADM-0801.F02 REV 2 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 974. *Year installed.

Abppkt~e ManAacdurers Data Repors lo be aadxed CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date N/A Sqinnedz&1

_z. ._e-a,. v w-

' r _

A or Owns Desigree, rife ic--~irilb Date ~6reL~tDate 20Q2L~

20 0r CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned, holding a vatid cbmmission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by H1SB CT of Hartford. CT have inspected the components described in this Owner's Report during the period 4x- A; '-p to ~fV.andstatethatto the ALL-best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Cbde. Section X1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4A--a"-J. Commissions A,2 All / CSKY~FV Nabona Board, Stale. Pronce, and Eridorsererds f

Date /2O - 20 AI5 Y

'a FORM Vz-ADM-0801.F02 REV 2 RTL # A4.414-A Form No. 1746 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY

- As Required by the Provisions of the ASME Code Section Xi 1; Owner. First Energy Corp Date November 10, 2004 (NAMo

- 76 South Main Street. Akron, OH 44308 -Sheet 1 of *2 (ADORESS)

2. Plant Beaver Valley Power Station Unit No. I Shippingport, PA 15077 --- 200069902. 200073924 ADORESS) Repa1epkacenwt Orgaiion P.O. No.. Job No..et.
3. Work Performed By FENOC - Construction - - - Type Code Symbol Stamp ' ' NiA  :

(NAME) , . , --

Shippingport, PA 15077. -_- -

  • Authorization No. NIA -,

(ADOESS)

Expiration Date '

4. Identification of System ' Feedwater, BV-1-24-System (Q2)
5. (a) Applicable Constnuction Code ANSI B31.1.0 .1967 Edition, S 1971.Addenda,

. Code Case (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 (c) Applicable Section XI Code Case(s) N/A

6. Identification of Components Co-ed~a. Cd Nm or Nam .f Ma.uf Nal Bod Wr Y.- Oe Stampe COf . MallfKIU SaW No. No!. . tderdfir"lm Baulk
  • uf (Yes eONo)

IFW-156A SCHUTTE & N-700484 * . . 1971. CORRECTED  : NO KOERTING

7. Description of Work - Motor operator and yoke removed 'and reassembled with replacement cover-for simple check valve. Valve repaired to allow complete disc swing without binding._
8. Tests Conducted: Hydrostatic* El Pneumatic* E Nominal Operating Pressure CD Exempt El Other El Pressure Normal psi Test Temp. Normal _ F

'Record test prsre and tenIperakre FORM Yz-ADM-0801.F02 REV 2 RTL # A4.414-A

I FORM NIS-2 (Back)

9. Remarks App" Mabarws DWU RepwU t be adadwd CERTIFICATE OF COMPLIANCE' I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/AN Certificate of Authorization No.

  • N/A Expiration Date N/A Signed i& 'L &--

O merworO0&W1D esagneeruse IYew Date tr 6 O _, 20 lb CERTIFICATE OF INSERVICE INSPECTION

1. the undersigned, holding a vali4,cornmission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of t- and employed by 'C- o -(I Cr-have inspected the components descnlbed In this.

Owners Report-during the period 5 / a. 0 to. toli . and state thaI the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures descnbed in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate nether the inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any persdnal injury or property damage ora loss of any kind arising frmor connected with this inspection.

Commissions j, W/J / 4 g,2..

N*ond Bor Stab [Iwme and rendmat j

Date /A-> - 2020!°Y i

A`

FORM 'A-ADM.0801.F02 REV 2 RTL NA4.414-A Form No. _ 1747.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner First Energy Corp Date November 10, 2004
  • ' ~'M{NME) '

76 South Main Street, Akron, OH 44308 - Sheet 1 of 2 (ADORESS)

2. Plant Beaver Valley Power Station Unit No. I Shippingport, PA 15077 .. . . I200069903.-200073925 ~

(ADDRESS* RepairiRqplactmonet Orgaaizatio P.O. No.. Job No, etc. .

3. Work Perfomned By FENOC - Construction -- --- - -'Type Code Symbol Stamp N/A (NAME)

Shippingport, PA 15077_ v - . Authorization No. - N/A (ADDRESS)

I Expiration Date -

NIA

4. Identification of System Feedwater, B1-I-24-System (02)
5. (a) Applicable Construction Code ANSI B31.1.0 1967 Edition, S 1971 Addenda, - Code Case' (b) Applcable Edition olSection XUtlized for RepairlReplacerment Activity 1989
  • (c) Applicable Section Xl Code Case(s) NIA
6. Identification of Components Carmacd. ASla4 raao ?4ioe Of HM~ralutu'ra ?4ateat Doad - oder Yewr or -Stamped Comp-ei I4Mtaawei SeeuI NO. Mo. 11demirial;0` Built butalled (Yes MrN)

IFW-156B SCHUTWTE& N-70-0485 . 1971- CORRECTED. NjO KOERTING

7. Description of Work - Motor operator and yoke removed and reassembled with replacement cover for simple check valve. Valve repaired to allow complete disc swing without binding._ _ _ _
8. Tests Conducted: Hydrostatic" 5 Pneumatic' [] Nominal Operating Pressure 0 Exempt El Other El Press ure Normal psi Test Temp. Normal_ 0F

. Ro~d test pressi. andten~erahJ FORM 'A-ADM-080 LF02 REV 2 RTL # A4.414-A

. r, FORM NIS-2 (Back)

9. Remarks Applicad. MaralhbWus Data RcpAvrtlsk otatawawd CERTIFICATE OF COMPUANCE I'certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. .N/A Expiration Date N/A . .

  • Signed /4z~tZ.Pod

&T~~ ,

densd!a t"e(

4leJ" Date I Z-1i 'a -Y - . .. 20 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of /*~and em~pbyed by/Vf of 11.41A r"~o'd c,7 -

  • have inspected the componerts described in this

)wAeh Report during the period 1/-.% to Ali ~ q and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or knpliedl. concerning the examinations and corrective measures descnbed inthis Owner's Report. Furthermore, neither the inspetor nor his employer shall be liable ini any manner for any personal irjury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions -

bispeda' s*r HatsorW Board. Siate P-oine ai nd smes Date /,,7.- Li- 20 ___

FORM 'A-ADM-080I.F02 REV 2 RTL #fA4.414-A Form No. _ 1748 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner First Energy Corp. Date November 10, 200 4 WJNE) 76 South Main Street, Akron, OH 44308 Sheet I of 2

.ADOPESS)

2. Plant BeaverValley'PowerStation . Unit No. I1 Shippingport, PA 15077 200069887. 200073926 '  ;

M(AORESS) Repairefdamnet Orgazaon P.O. No.. kJb No, ee -.

3. Work Performed By FENOC - Constniction - Type Code Symbol Stamp': 'N/A'

.(NM)

Shippingport, PA 15077 Authorization No. N/A (ADDRESS)

. Expiration Date N/A

-4. Identification of System Feedwater, BV-1-24-System (Q2)

.5. (a) Applicable Construction Code ' ANSI B31.1.0 1967 - Edition, S 1971 Addenda,. - Code Case (b) Applicable Edition o Section Xl Utiried for RepairReplacenment Activy 1989 (c) 'ApplicableSection Xl Code Case(s) NWA .

. . I -. ; " .

6. identification of Components ASME.

corctd .

Hameot NIameof mamdfacutrer NgKaIW Board ofiher year rstaimped CooVpoeoin xu . Scrlwat-on NO. NO. Built jIfunJ .d (Y-ac 14b).

IFW-156C *SCH-UTrE& N-700483 -- 1971 -CORRECTED NO

  • KOERTIlNG 7./ Description of Work - Motor operator and yoke removed and reassembled with replacement cover for simple check valve. Valve'repaired to allow complete disc swing without binding.
8. Tests Conducted: Hydrostatic* E PneumaticeA Nominal Operating Pressure [ Exempt El Other 5 Pressure Normal psi Test Temp. Normal__ F Record test pressue andtemperatcse FORM Y 2-ADM-0801LF02 REV 2 RTL # A4.414-A

. I FORM NIS-2 (Back)

9. Remarks A*p*Ao Muaowacw's Das FbRUrts lo be idaded

. I CERTIFICATE OF COMPLANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code. Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. NA . Expiratiton Date N/A-Sioned r414Wt

-Ae44aax . Date _ 20_-

-I

-_oww ow*oees 544vs v

e lb .

- CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of a-rnd empoyed by ______ __ of 4,e d, c7

.have inspected the components described in this Owners Report during the period 9 I z

  • to /- Y.and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or inplied, concerning the examinations and corrective measures descnbed in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

- 3zZ - Commissions ., =v 'J /64f .

NationxBard. State. Provug. am Erhdsemnft r

Date /Z- (P - _,.20 ( Y

FORM 'i-ADM-0801.F02 REV 2 RTL # A4.4 14-A-Form No. 1751 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C. Date 12114/2004 (NAME) 76 South Main Street - Akron. OH 44308 Sheet I of I (ADFWMES)
2. Plant Rpavtr VqIlev Pnwer St~tion

Unit No. 1 ._.

(NAME) ,

Rnite IRI -A 5hinninnnort PA 15077 Order #20001538i0f (ADORESS) RepaiRepiacent Organizali P.O. No. Jcb No. ell-

3. Work Performed By BVPS-Maintenance Type Code Symbol Stamp NIA (NAME)

Route 168 - Shipoinaport, PA 15077 Authorization No. N/A (ADORESS)

Expiration Date N/A

4. Identification of System River Water (Q31
5. (a) Applicable Construction Code ANSI 133.1 1967 Edition. 71 Addenda. NWA Code Case (b) Applicable Edition of Section Xi Utilized for Repair/Replacefnent Activity 1989 (c) Applicable Section Xl Code Case(s): NIA .
6. Identification of Components Cosrwde& ASME R.,.n.d. COb N~ of Navn or maaa~wtav Nmkwl Dowd OeYew or Scmped CxClVr Mfaru - se NO No. Uificaon oMAr Lbtlhd (Yes or No)

Gate Valve Crane N/A MOV-I RW-I 13A _ Removed No Gate Valve FlowserVe E634TI1- N/A' MOV-IRW-113A 2002 Installed No

. .' X

7. Description of Work Replaced valve and inletloutlet studs, nuts.
8. Tests Conducted: Hydrostatic' [l Pneumatic' E Nominal Operating Pressure 0 Exempt l Other El Pressure psi Test Temp. F Record lest pressuwe and apetaure

FORM VzrADM-080 1.F02 REV 2 RTL A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. New valve was designed in accordance with A~~cle Mcta s Rata RXl 3 be aftatsed ANSI B16.34-1988 Edition. RePlacement Studs: 5/8" UNC Ht. No. 537388 D352. Nuts: 5/8" UNC Ht. No. D874.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and thatthis conforms to the requirements of the ASME Code, Section Xi.

Type Code Symbol Stamp NIA Certificate of Authorization No. NIA Expiration Date N/A Signed-1 ~ , -&. ,,.-I, 7 -/_e ,,

Date J !5' 20 6

%Owrw o Owrers Deslwve. Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owner's Reportd uring the period 4_Z2 6-3 to - and statethattothe best of my knowiedge and belief. the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

.A,-M, -J 1j Commissions 4A nL 7 .4.'? Y National Board, State. Proance. and Erndasenents Date / -/J- 2

, 20v>

FORM Mr-ADM-0801.F02 REV 2 RTL # A4.414 -A Form No. 1752 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner F.E.N.O.C. Date 12/1412004 (NAME) 76 South Main Street -Akron. OH 44308 Sheet 1 of 1 EADDRESS)
2. Plant Beaver Valley Power Station Unit No. 1 (NAME) . .. -. . ... .. I Rnute I6R - Shinninannrt PA 15077 Ordelr #2000n1 5411 (ADDRESS) ---------- P.O. No.. Job No.. etc.

RepaireReaceTrN Orgarization

3. Work Performed By BVPS-Maintenance Typa Code Symbol Stamp N/A (NAME)

Route 168- Shippinqjort, PA 15077 Authorization No. - N/A (ADORESS)

Expiration Date N/A

4. Identification of System River Water (Q3)
5. (a) Appricable Construction Code ANSI 1331.1 1967 Edition. 71 Addenda. WA Code Case (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Acbvity_ 1989 (c) Applicable Section XI Code Case(s): N/A
6. Identification of Components Corrected. ASME Renow.~d CO&e Narm of Narn, or M.NraNational od Oler Yee a, Sltaned CoaWou Mfactder SNo.No"IO No .l ir icon l DU 'taled I. (Yes at No)

Gate Valve Crane N/A MOV-IRW-l 13B __ Removed No Gate Valve Flowserve E634TI-2 NIA MOV-1RW-113B 2002 Installed No

7. Description of Work Replaced valve and inlet/outlet studs, nuts.
8. Tests Conducted: Hydrostatic" E Pneumatic D Nominal Operating Pressure 0 Exempt LI Other D Pressure psi Test Temp. . .OF
  • Record lest presstme and Nereralture,

I I

FORM 'A-ADM-0801.F02 REV 2 RTL It A4.4 14-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. New valve was designed in accordance with Appkabe UMamAdwes Dra Repoul to be aftad ANSI B16.34-1988 Edition. Replacement Studs: 518" UNC Ht. No. 538169 H177 Nuts: 518" UNC Ht. No. H660.

CERTIFICATE OF. COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code.Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

,5wor6 V Date ,= 1*5 Owner or OAds Desigeemde I CERTIFICATE OF INSERVICE INSPECTION

1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT have Inspected the components described in this Owners Report during the period VM  :(0 -0 3 to /L - Z- Y.-and stethat to the best or my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code. Section XL.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the inspector nor his'employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

jg, I. 1- / Commiss"os Go Naboa" 4J, A°4 3F Bowa.Sae. Prowice. and Erdoemwts Date / 0 L _ /J-2 . 20 Si;(

FORM Vz-ADM-0801.F02 REV 2 RTL # A4.414-A Form No. 1753 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C. Date 12/14/2004 (NAME) 76 South Main Street -Akron, OH 44308 Sheet 1 of I (ADDRESS)
2. Plant Beaver Valley Power Station ----- Unit No. 1 AM ) ' .  ; -  !,

Route 168- Shinninanort- PA 15077 Order #200015338

  • (ADDRESS) lKezxwRepac ent Orgarizabn P.O. No. Job No.. etc.
3. Work Performed By . BVPS-Maintenance TypeSCode Symb ol Stamp N/A Route 168- Shippinaport. PA'1 5077 - - Authorization No. ' N/A (ADDRESS)

. . - .r Expiration Date N/A

4. Identification of System River Water (03)

- '1!t,

5. (a) Applicable Construction Code ANSI 831.1 1967 Edition, 71 Addenda, N/A Code Case (b) Applicable Edition of Section XlUtilzed for Repai(/ReplacementActivity 1989 (c) Applicable Section XI Code Case(s): N/A
6. Identification of Components correced. ASME R emoed. Cod Nameor Name of Manuractm ,Navt~al Boad Other Year or Stamped C oeu martfacturer Serial No, No,' -dctifiwo 8 dk stlaed (Yes or No)

Gate Valve Crane 914439-1 -N/A - MOV-l RW-I 13C Removed No Gate Valve Flowserve E634TI-3 N/A MOV-1 RW-I 13C 2003 Installed No

7. Description of Work - Replaced valve and inlet/outlet studs, nuts. - -
8. Tests Conducted: Hydrostatic'* Pneumatic' [] Nominal Operating Pressure ED Exempt l Other 0 Pressure psi Test Temp. . .OF Record best pessire and lerTperahxe

I FORM Y/i-ADM-080I.F02 REV 2 RTL N A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 444. New valve was Appwicare Mantoadkees Wsa Reprts 10 be afloaded fdesiannd in accordance with ANSI RlRl.4-1Q8R Edition. Renlacenment Studs: 518" UNC Ht No.

537388. Nuts: 5/8" UNC Ht. No. H660.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl. .

Type Code Symbol Stamp. NIA Certificate of Authorization No. NWA Expiration Date N/A Signed 4(4aM4- onm& Owners Desee. Trie xr 40hgdJsr Date xxw4" Is 20 64 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSQ CT of Hartford, CT have inspected the components described in this Owners Report during'the period 4/-A ; - 4P to /1. - - Y and state that to the best of my knowledge and belief, the Owner has performed examinatiQons and taken corrective measures described in this Owneres Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's ReporL Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.

s Z 9

l?_ Jk( A/ Comnmissions rn go;o

.Nabona aoad.

As r Stai. Prokxce. xW Endorseincts Date . 20

. 20 "

FORM VI-ADM-080L.F02 REV 2 RTL ftA4.414-A Form No. 1754 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY

- As Required by the Provisions of the ASME Code Section Xl

1. Owner F.E.N.O.C. Date 1211412004 (NAIAE) 76 South Main Street - Akron. OH 44308 Sheet I of. I (ADDRESS)
2. Plant Beaver Valley Power Station . . Unit No. I (NAME) e 1 6 (NoMt P -A 150 77 .t Route 168 - Shiooinooort. PA .15077 Order #200017496 (ADDRESS) RepairlReplacenie Orgarizabonr P.O. No. Job No.. etc.

i .

3. Work Performed By BVPS-Maintenance Typt Code Symbol Stamp N/A (NAME)

Route 168 - Shiopinaport. PA 15077 ^ Authorization No. N/A (ADORESS)

Expiration Date N/A

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S71 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Uilized for RepairlReplacenent Activity 1989 (c) Applicable Section Xl Code Case(s): N/A
6. Identification of Components Comd . ASME Rem-ed. COde Nameof Naoe of MamBfarer N.aiboal oard other Yea or Stavped Coo mni Madrfana"re Sodel No No. idrerdfcni~on B.,l InstaWed (YS or No)

Gate Valve Wallworth C58195  : 555 MOV-IRW-113DI 1975. Removed Yes Gate Valve Flowserve E634T14 x N/A ,

MOV-IRW-113Dl 203 Installed No

7. Description of Work Renlaced valve and inlet/outlet flange studs, nuts.
8. Tests Conducted: Hydrostatic' ] Pneumatic* [] Nominal Operating Pressure C Exempt El Other 0 Pressure psi Test Temp. ___ OF

'Record lest presstse and lenperattse

FORM 'A-ADM-0801.F02 REV 2 RTL tHA4.4114-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No.434. New valve was AppWicatie gapdbouesData epwls lo be awtadted desianed in accordance with ANS B1 6.34-1988 Edition. Reolacement Studs: 5/8" UNC. Ht. No.

537388. Nuts: 518" UNC. Ht. No. G7030 F639 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.  %

Type Code Symbol Stamp NIA Certificate of Authorization No. N/A Expiration Date N/A Signed .'y SMar gSA 1/sr Date . )'~ JS

- vOves Deskgne, Mee CERTIFICATE OF INSERVICE INSPECTION 1 the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owner's Report during the period i - 3 to t-A A /andstatethattothe best of my knowledge and belief. the Owner has pedomied examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owner's Report Furthermore. neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions Z, W A'/dAyircS 2 g Insped Cl5lSatue, r National Boad. Stale Prny4nev and Endorserffws Date /20 XJ- , 20 )KY_

4 .

FORM 'V-ADM-0801.F02 REV 2 RTL #A4.414-A Form No. 1756 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY

  • As Required by the Provisions of the ASME Code Section Xi
1. Owner F.E-N.O.C. - : ,' ' .Date . 12115/2004 76 South Main Street - Akron, OH 44308 -_ .Sheet 1 - of 1 (ADOWrSS)
2. Plant Beaver Valley Power Station . Unit No. I NEA) I . .::  :.

Route 168- ShinDinaoort, PA 15077 Order #200072006 (ADORESS) Repaw/Retacenw Orgabzain P.O. No, Job No. etc.

3. Work Performed By BVPS-Maintenance Type Code Symbol Stamp N/A (NAME)

Route 168- Shippingport, PA 15077 - Authorization No. N/A (ADRfESS)

Expiration Date N/A

4. Identification of System River Water (03)
5. (a) Applicable Construction Code ANSI 831.1 1967 Edition. S71 ,kddenda. - Code Case (b) Applicable Edition of Section Xl Utilized or Repair/Replacement Activityly (c) Applicable Section Xi Code Case(s)
6. Identification of Components

.-Fcrrecd. ASME N of NNe of . Mrfanure .. Naioa Dowd Other Ye or Supead Cc. oel g lefscwer Se"isaNo No. Idcmificon

.. Bai Insuflrm (Yes or 1HoN Check Valve C & S Valve 89.0929Otl(Q)-Ol N/A IRW-106 - corrected No

7. Description of Work Replaced valve inletloutlet flange studs and nuts.
8. Tests Conducted: Hydrostatic' El Pneumatic' 5 Nominal Operating Pressure D Exempt E Other El Pressure psi Test Temp. OF Aemd iest presste andtervereatmee

FMRr ORL FORM Vi-ADM-0801I17O2 REV 2 RTL HA4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Reports available. Previous NIS-2 Data Report Nos: 1220. 654. Inlet and Apkiabe UtuaadgWS Data Reportsto0 be aded outlet studs and nuts were replaced. Valve was manufactured to ANSI B311 1973E and 816.34 1981 Edition. New 1-1/4" studs Ht #K339. info on nuts is not available.

CERTIFICATE OF COMPLIANCE I certify that the statements'made in the report are correct and that this conforms to the requirements of the ASME Code. Section Xl.

Type Code Symbol Stamp, N/A Certificate of Authorization No. N/A Expiration Date N/A Signed , 5a.

tncsrcc a tXme icL I Date TI4- )-.

-- ^Xe .af o -. <f Ih CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and tie State or Province of Pennsvivania and employed by HSB CT of Hartford. CT have inspected the components described in this Owner's Report during the period <- t 3 to A -. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code.Section X).

fy signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's ReporL Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

.~~~

a.J A, t Comsnsisslons :2: /f3 Am TY

' hs2~v &hhe r Natonal Board. State. Prowie, ard Edrw ts Date / 2Z -/ 202 JQw O

FORM VrIADM-080l.F02 REV 2 RTL N A4.414-A Form No. 1757 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY

- - -As Required by the Provisions of the ASME Code Section Xi

.1. Owner F.E.N.O.C. Date 12/15/ 2004 (NAWE) 76 South Main Street - Akron, OH 44308 - __ Sheet 1 - of 1 (ADORESS)

2. Plant Beaver Valley Power Station Unit No. I 1- )

(NRUt - h A 1 -- - '['

Rouifte I168 - Rhinninaonrl. PA 15077 Order #200120728 (ADORESS) _--------- P.O. Mo. Job No-. 4c.

RPq-&wieswaem!nitOrgri~zaftn

3. Work Performed By BVPS-Maintenance Type! Code Symbi Stamp M N/A Route 168- Shippingport PA 15077 '-Authorization No. N/AI (ADOFESS) N/A'

.Expiration Date

4. Identification of System River Water (03)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition. S71 Addenda. N'A Code Case (b) Applicable Edition of Section Xi Utiized for Repair/Replacement Activity 1989 (c) Applicable Section Xl Code Case(s): N-416-2
6. Identification of Components C-. .Ired. ASME Remnae COde Nae or Nam of M.r.6auecr . Na... Od Other Yea or Sianped cb.voneaecau SaritlNo O. . d tmickatio. - -1 Insualed (Yes or N0l Pipe Stone& N!A l N/A WR-14 1993 Corrected No Webster 7D. s n o Wor

.pi Re a .e o .,.h l , a .k in w Ael . WR 1 Fp.- .s , -- .

8. Tests Conducted: Hydrostatic* [ Pneumatic E Nominal Operating Pressure C Exempt a Other [] Pressure psi Test Temp. OF Record test presswre and SenVfealtre

FORM Yz-ADM-080I.F02 REV 2 RTL HA4,414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Previous NIS-2 Data Report Nos: 410. 189.

AWsmeable Uargiadhxes Data eports to be atladsed CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code. Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date N/A Signed e So 5t 1es- Date r- j '

Oe 0 Desixee. Tde -

f Ownees I*

CERTIFICATE OF INSERVICE INSPECTION

1. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owner's Report during the period
  • A 'a - to e 7z 3s *I. and state that to the best of my knowledge and belief. the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Owner's ReporL Furthermore. neither the inspector nor his employer shaD be Wable hI any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Coamnissions _ , /4 2tt iS onave f ahbX BcomdB Se.PMroince. an Endorsefferf Date /--/7- 20 ff V

FORM 'hADM-080I.F02 REV 2 RTL # A4.414-A Form No. 1759 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner First Energy Corp Date November 10, 2004 7St tE) o O a 76 South Main Street, Akron, OH 44308 Sheet I of 2
2. Plant . Beaver Valley Power Station -- . - Unit No. I (NAME) '-

Shippinqport, PA 15077 200015446 (ADDRESS) Repa.irm..*aceme Orgaizabon P.D. No.. Job No, etc.

.3. Work Performed By FENOC - Construction Type Code Symbol Stamp N/A (NAME)

Shippingoort, PA 15077 Authorization No. N/A (ADDRESS)

Expiration Date N/A 4 Idpntifientinn of Rv-fttm FPedwaiter RV-1-A4-Svhtem (03)

5. (a) Appricable Construction Code ANSI 831.1.0 1967 Edition, S 1971 Addenda. - Code Case (b) Applicable Edition of Section Xl Ulized for Repair/Replacement Activity 1989 (c) Applicable Section Xl Code Case(s) N-41r,-2
6. Identification of Components '..

Cfe e. f A S1 E.5M nf.eofear. Code No e(Name a Mm ~Utar.wNational other Yew oStanfcd Conpnem MA-.acWtr SerialINo. Dowd 4dangificatoan S.;hfloululed (Yes o No)

. =- ?4o=.

FE-14FW-IO IB. VALCOR 2 . 2002 INSTALLED, NO

7. Description of Work Installation of cavitating venturis into the Auxiliary Feedwater System lines feeding the steam generators
8. Tests Conducted: Hydrostatic* [] Pneumatic* Cl Nominal Operating Pressure l Exempt El Other 0 Pressure Normal psi Test Temp. Normal "F

'Record test pMessmze 4ndtenrperae

. I I FORM MA-ADM-0801.F02 REV 2 RTL A4.414-A FORM NIS-2 (Back)

9. Remarks Appikc MaTurtu's 0at Rep" lo be id CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Dale N/A Signed M 0. - 9 0www0*nsDoes4,..

Date I2b/df20 CERTIFICATE.OF'INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Z wand employed by 14AC7`of w d C at, 7 -

' have inspected the components described in this Owner's Report during the period M___C_-_°__ to 1A .2L- ,- (*.. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report n accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or inplied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the inspector nor his employer shal be lable in any manner for any personal irnury or property damage or a loss of any kind arising from or connected with this inspection.

__ __ _ Commissions Ha re t° 3 SV Nationa Board. StaW Prov&= and Enarsemarts Date /2- .

0-

.20 LdtS

FORM %-ADM-080I.F02 REV 2 RTL Y A4.414-A Form No. 1760 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the'Provisions of the ASME Code Section Xi

1. Owner 'First Energy Corp - Date November 10,22004

'76 South Main Street, Akron, OH 44308 Sheet -1 bf 2 (ADORESS)

2. Plant Beaver Valley Power Station - - - ' ' - Unit No. I (NAMECI  : -. "

Shinpingport, PA 15077 200015455.

(ADODRESS) :RepaReplacat Orgaizatior P.O. Nob.No.5 etc

3. Work Perforrned By FENOC - Construction Typ'e Code Symbol Stamp Nq/A '

-Shinpinqport. PA 15077 Authorization No., N/A (ADORESS)

'. - Expiration Date - N/A
4. Identification of System r 5t.tg fl01 5.

. Lsv-,z--";z ruwt fr) Al . .

5. (a) Applicable Construction Code ANSI B31.1.0 -_1967 Edition. S 1971 Addenda. - Code Case (b) Applicable Edition of Section Xl Ublized foi RepairlReplacement Activity 1989-.

(c) Applicabe Section Xi Code Case(s) N.416- .. . ..

6. Identification of Components Corredod. ASME

. I-Naeof NNW of .. N . Oder Oth., Yew . . or . *Stmpd CO(Jl_;1)C5W e seio NO B Noard ldotWdn Bulk (Yes orf4)

FE-lFW-IOIC VALCOR 3 . _ -. . 2002 INSTALLED NO

.7. Description of Work Installation of cavitatinq venturis into the Auxiliary Feedwater System lines feeding the steam generators

8. Tests Conducted: Hydrostatic*.[] Pneumatic* [] Nominal Operating Pressure ID Exempt LI Other Ol Pressure Normal psi' Test Temp. Normal °F

'Recrd test pressure and temperature

z FORM 'K-ADM-080LF02 REV 2 RTL #A4.414-A FORM NIS-2 (Back)

9. Remarks

.AppiucabsMaraatm 's Dats Reportub be aJeaded CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp NIA Certificate of Authorization No. NMA Expiration Date NMA Signed &/ I A bil.it Dale b /1 &to . .-

-,2 20

  1. odWs r'esi ee. rft L)

L .;

CERTIFICATE.OFINSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of 'iand employed by IHC4*? of .,11 oe- o-G C7-have inspected the components described in this Owner's Report during thepeiod c/_ et I 0°3 to oY . and state that to the best of my kniowledge and belief. the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owner's ReporL Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury. or property damage or a loss of any kind arising from or connected with this inspection.

tCommnssions oa ad Natona Bard. soe Premvin ua Date - _,20- L°) j *-(

A .t

.FORM Wil-ADM-080I.F02 REV 2 .RTh #AA4 ,A. -:.

. orm. .

  • ' ' Form No. 1761 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
1. Owner First Enerqv Nudear Operating Company Date 12/02/04 76 South Main Street - Akron, OH 44308 . Sheet I bf I (AD S ) . . .. . .
2. Plant Beaver Valley Power Station . Unit No. 1 Route 168. Shioninatort, PA 1507 Westinqhouse P.O. 7024829 (AlOFTESS Repaki~ejacmer' Orgtza~o PMO. No. Jab Ho, eec-
3. Work Performed By BVPS=6eaI POiects T e Code Symbol Stamp- 'iA ',.

Shippinaportn PA15077- AuthorizationNo. .- N/A:-*:: .l .-.

, . Z~OOS)_ . .. _ .-

Expiration Date N/A

... . I .I

4. Identification of System Reactor Cootot .(Qi) .: -
5. (a) Appllkble Conshcton Code ectil 1965EWition W66 Addenda. . -Ce

'1429 *s.

(b) Aplcabe Edtion d Sedion )X Utilized for Repar/ReploaometAbvty 1989 Edition No Addenda:

(c) ApplWcable Section b Code Case(s)

6. Identification of Components

. .. . .~

lk-td. ro&

Numot NUMr or . .. _ ,  : N I dodhei'. 'r~ . 4 ,'led'K,-

C Ma.rac'tww S o. No *,, l . (Yuer  : .

Steam Westinghouse' DLGT-1301 - 68-45 IRC-E-IA 1971 Corrected ::Yes, -

Generator

7. Description of Work Installed 208 Inconel 690 tube plugs (104 tubes). Installed new qaskets on primary manways & secondatr sidehandholes. -
8. Tests Conducted: Hydrostatic* ] Pneumatic El Nominal Operating Pressure IS Exempt El Other El Pressure psi Test Temp. OF

I FORM'/,ADM-080LF02 REV22TL #44ii A FORM NIS-2 (Back)

  • . -C
9. Remarks ASMEWork Order: ffuMi.Ploii) i 0b06249.

4je Mx ac*ws ata Rep to be :ad,.ed PA 434597

~~~*  :. - ;...-*.

CERTIFICATE OF COMPLIANCE...

I certify that the statements made in the report are correct'and that this confuns. to the requirements of the ASME Code, Section Xl.  ; ' '  : 'S. -'" 7' Type Code Symbol Stamp per 1/2 ADM 0801.. ASME Section Xl ReoalrlRedlacement &.Revair/mertion Program' Certificate of Authorization No. NIA Expiration Date N/A Signed V&s.4k[t 4A a Date December02 , 20 04

~.

CERTIFICATE OF INSERVICE INSPECTION

1. the undersigned. holdicng a valid commnliskr issued by the National Board of Bodler and Pressure Vessel Inspectors and the State or Pnovnce of Pennsylvania and employed by S4g C 7 of Ar o4 7 oC ¢, c-.r have inspedj the cxmponents described In this Owne's Report durng the perlod X 6-P3

&A to / -A / and state that to the best of my knowledge and belief, the Owner has peufbrmed examinations and taken correctiv measures desaibed In this Owneres Report In accordance wvth the requirements of the ASME Code. Section Xl.

By signing this certifcate neMer the kispector nor his employer makes any warranty, expressed or impled. concering the examinations and corrective measures des Tbedn this Ownee's Report Furhmore neither the inspector nor his empoyer shall be liable in any mnnr for any personal injury or property damage or a loss of any kind artstng from or connected with this inspection.

__Commissions 2 Daat Dowd StK PZ r E2d _ .

Date - 2,:2 ..

. .. . !'e; .  : I :;

FORM %-ADM-080 LF02 REV 2 RTL #'A4Ai4-A

  • T .i*

Form'No. 1762 FORM NIS-2 OWNER'S REPORT FOR 'REPAIR. ,FEP.CEMENTACTIVITY As Requlred by the Provisions of O SME(o'dS Section XI

1. O'wner First Energy Nuclear Operatinq Co nanv Date :--,- - . 12/02/04 76 South Main Street - Akron. OH 44308 ^She6t 1- of 1I (AMss)
2. Plant -Beaver Vallev Power Station , Unit No. '_ I Route 168. ShiDpingport. PA 15077 Westinghouse P.O. 7024829 tacanPee OgaFo P. Ho..b Job N~o
o. ec,, ,
3. Work Performed By BVPSISpecial Proiects Type Code Symbol Stamp N/A Shippinqport, PA 15077 Authorization No. N/A (AflORM)

- - Expiration Date _ _ N/A  ; .. ; ..

4. Identification of System Reactor Coolant (Q1) ... .  :
5. (a) Applicable Construction Code SectiorilIl 1965 EditIOn. .66 Addenda. - 1429 Code Case (d) Appricable Edition of Sec6ion ) Utlized for RepairtRepiacemnent Actyvi 1989 Edition No Addenda (e) Applicable Section Xl Code Case(s)

,6. Identification of Components Cworoa4d. ASMNE Rmld. .Oe Nu= of w4mi or mambfduw N~A;I Dowd Orbor Year or Smo Caia . . .u S.- No. No . - - .& 0 sea L.au..,

-d .. (Y-.,.,

Steamto Westinghouse DLGT-1302 68A46 1RC-E-IB 1971 Corrected Yes Generator

7. Description of Work Installed 80 Inconel 690 tube plugs (40 tubes). Installed new gaskets on primary manways & secondary side handholes.
8. Tests Conducted: Hydrostatic*

I El Pneumatic* 5] Nominal Operating Pressure 0 Exempt O Other O] - Pressure psi Test Temp.

  • OF WM pvsswe ad $en'erat" dRecoM

FORM 'z-rADM-0801.F02 REV2 RTL # A44i4-A .

FORM NIS-2 (Back)

9. Remarks ASME WorkOrder6 ( PIiuarn')290O62495 '
  • ' P1CAbi EJfa 013"bPAPOUtb be id.ed . -. .

PA 434598 CERTIFICATE OF COMPLIANCE' .-

I cethat the staternents mde in 616'report are conect and that'this cont to thereqiMents of the ASME Code, Section Xl.

Type Code Symbol Stamp er 1/2 ADM-0801. ASME Section Xi Repair/Renlaceme'nt & Reoair/Aiteration Pronramw Certificate of Authorization No. N/A . Expiration Date N/A

.)&X& q 1.

Signed C Date -December 02 C.~ Oworw Des~ioe4ilfle ees I CERTIFICATE OF INSERVICE INSPECTION 1.the undersige, holding a valid comnission issued by the Nabonal Board of Boler and Pressure Vessel Inspectors and th State or Proance of Pennsyvvania and employed by 4ofa C 7 .

e have spected the cornponents described In this Owne's Report durlng the peMMd 9f- C 36 to loz - A"- -4 ' . and state that to the best of my knWege and belief, th' Owner has'perfonned examinations and taken corrective measures described inthis Owner's Report hI accordance with the requirements of the ASME Code. Section M.

By signing tIS certficate neither the inspector nor his employer makes any wanranty, expressed or inplied, concerming the exarninadions and corrective measures described hI this Ownees Report Furtherore, neitUer Oe inspector nor his employer shall be lable In any manner for any personal kirny or property damage or a loss of any kind arising fron or connected with aiis ispecion.

Commissions A 9 'IA '44r'I: Y Natkm Bord. SWe. Pro%*Ice and orsewt Date /-.2- _, 20 0- 0(1

i:

I. I. .

Rlls A -. I.. * . :. :.

Form No. 1763 FORM NIS;2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X';;

1 Owner FirstEnergyNudearOperatinqGComnanv Date 12/02104 76 South Main Street - Akron; OH 44308 Sheet I of I AR). .

2. Plant Beaver Valley Power Station Unit No. I Route 168. Shipinqport. PA 15077 ^ _ Westifnhouse P.O. 7024829 (ADDRESS) R.epaocmeM Orgzion P.O. No, Job Nod e.c.
3. Wok Pe iflo-rTLedJy B ..

SP...*A BPSPTydot .. .....A Shiwninqgort.)PA15077 -. . -. -'Auithorization .-WA

'...- t^; . - ..

Expiration Date NIA 4.. Identification of System Reactor Coolant (Q1) *

5. (a) Applicable Constructon Code Section II 196 5 Addna , .1429 Codease l (Q) AWplicable diio SecionX dof Utlized fo RepairReplacementActity 1989 Edition No Addenl (g) Applicable Section n Code Case(s)
6. Identification of Components 4

Nuc=of - 1aW4 or MMtutcfer wa ion d od;- 3.or, *.

Coa s. r . Scri N - No. Idoadidcatio= I. a- .- (Ya or-,

.IC-I . . ret .Y.,..................;,.:es-.

.--j Steam WestinghDouse DLGT-1303 6847 IRCE-IC 1971; Corrected .Yes Generator . - . . .. .

_ =',' -'.. _ _ = _,,,

7. Description of Work Installed 104 Inconel 690 tube plugs (52 tubes). Installed new gaskets on -

primary manways & secondary side handholes. Replaced I Primary MNV stud.'

8. Tests Conducted: Hydrostatic' 0 Pneumatic Nominal Operating Pressure IE1 Exempt 0 Other O Pressure psi Test Temp. OF

'Record lest presswe and lerperAxe

I FORM ir D41iOtl0 ITEV 2 RTCI '4A W4A "

FORM NIS-2 (Back) 9.- Remarks ASEWrkri APP!C~ ~ ~ e -tshb ade -

accA

&6 iq eq primr manWay (C6t0C1 PA434599

  • :. O. .* . .... . . ..

v  :.

CERTIFICATE OF COMPIUANCE

-wil. *I. .

.I%  ;~~.h I certify tat te statements rade in the report'are correct and that this confbnns to the requirements of the ASME I.....

Code, Se ymon XI;. .:. ;m : r t -r..: & Re. ;. .- ti am".

Type Code Symbol Stamp- perir/2ADM480l; wASMErSeclathXIRepair/Redlaceffent &RepairlA~teation Prorarir Certificate of Authorization No. WA Expiration Date W NA Signed A X q5Date December02 _. 20. 04

.- ) o e ,.Date CERTIFICATE OF INSERVICE INSPECTION 1.the unidersigned. hling a varid commission issued by the National Board of Boiler and Pressure Vessel nispetors and the State'or ProVne. of Pennsvania and employed by 6ALd C 7° Of WZ e77"o e ¢.. c r- - have inspected the components descnlbd hI this.

OwneesRepo durigthepedod U to _____,______

best of my knowledge and belief, the Owner has perfor'ed exaninations and taken corredive measures described hI this Owne~s Report In accordamce with the requirements of te ASME Code. Section )(.

By signing this cetlikate neither the inspector nor Ns empoyer makes any warranty, expressed or implied, corcen*n the exailnarions and correctve measures descabed n this Owners Report Furthermore, neither the inspector nor his employer shal be liable in any manner for any personal injury or property damage or a loss of any kind aring fromn or onn nth jffed this inspection.

Aa,,.... Commissions ,fS Y1r ,9A'4' Habond 00rd stae- Pr4~nc and Odarsamf Zj Date / o ' t - - .  ; 20 J

i; RTL # A4.414-A Form No. 1772 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C. Date - 1118 /05 (NAM) 76 South Main Street - Akron. OH 44308 Sheet 1 of I (A.DO.) . -

9 .Plant

6. Icky .. Renaver Vaflev Pnwer Station Unit No. I1 (NAM)

Shipbingport. PA 15077 - ---

(ADlORSS) REPAIR ORGANIZATION P.O. NO, JOB NO, EC.

3. Woik.Performed By Plant Enoineerina Type Code Symbol Stamp Not ADorcable

- 5 7

{NAMEo P,or qhinninnport PA1--7 Authorization No. NIA

{ADMRESS)I

-E Expiration Date

4. Identification of System -Reactor Comroonent Cooling
5. (a) Applicable Constdion Code ANSI 831.1 19ff Edition. S7 Addenda. NIA Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989E
6. Identification of Components Repaired or Replaced and Replacements Components ePaired. ASME RP^A-ed. Code Name or Name Of aacurer Na"onl Dord ~Otr Year Or Stared ConTVoneni curaer Se"i Nnt NO. Ideiccation &it Repacement (YES NO

_ _ _ __ __ _ _ _ _ _ __ _ _ _ _ _ _ NO )

Snubber Pacific-Scientific 24499 NA CG-HSS-021B - -Replaced No Snubber Pacific-Scientific 16932 N/A CG-HSS-021B - Replacement No

7. Description of Work Reolaced snubber with spare for testing/refurbishment Purposes.
8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure E Other El Pressure psi Test Temp. __ OF

FORM NIS-2 (Back)

9. Remarks The snubbers were replaced with a used snare rotated from stock: No Code Data Reports are available, The snubber's were purchased non-NF components (non-code).

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code Section Xl. Repair Or Run acerd Type Code Symbol Stamp N/A' Certificate of Authorization No. NMA Expiration Date NWA Signed e o 4 S 4.u ( Date To-_ I ,. 2005 cOwmas Desige TOC CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned, holding a vafld commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of I-Hartford. CT. have Inspected the components described in the Owners Report during the period __________ to /' a Th and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Ownees Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shal be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

,X~ -I'.

b- ,gnehwe Commissions -Z, -J, 4, 3 33Y

?aboraj Board. Stale, PiAe. arid Endorserft Date / - .tf /- , 2005

RTL # A4.414-A Form No. 1773 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the-ASME Code Section Xi

1. Owner F.E.N.O.C. - ..* Date 1/18105 76 South Main Street - Akron. OH 44308 Sheet I of I (ADDRESS)
2. Plant Beaver Valley Power Station ' 'Unit No. I Shiobinboort. PA 15077 i -
  • W-.- - 200066374

{(ADDRESS) REPAR ORCANVAz N PM. NO, JOB NO, ErTC

3. Work Performed By Plant Enuineering type Code Symbol Stamp iW urge hiin P Shinninnnort. PA 15077 Authorization No. N/A

. .(ADORESS)

Expiration Date

4. Identification of System Reactor Coolant (Non 0. but within first anchor)
5. (a) Applicabte Consthxcion Code ANSI 131.1 19ff Edition. S71 Addenda. N/A Code Case (b) Appbcable Edition of Section X1 UliizedforRepairs or Replacements 1989E
6. Identification of Components Repaired or Replaced and Replacements Components Re.padASME Reo~aoed. COwe Me ci Nrme 0i Maabadxer 6dorW Boerd 0e Year Or Stamped Corwaief4 MamAadkm Serl No. NO. Ide.. can _._ Rueptgt (YES or Snubber Paii: _O) 6H No Snubber Pacific-Scientific 3699 N/A RC-PSSP-129 _ Replaced No Snubber Pacific-Scientific 3694 NIA RC-PSSP-129 - Replacement No 7.: Description of Work Replaced snubber with snare for testingfrefurbishment purposes.
8. Tests Conducted: Hydrostatic [I Pneumatic O Nominal Operating Pressure El Other E Pressure _ _ psi Test Temp. .F

FORM NIS-2 (Back)

9. Remarks The snubbers were replaced with a used smare rotated from stock. No Code Data Reports are available. The snubbers were purchased non-NF components (non-code).

CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this Reolacement conforms to the rules of the ASME Code Section Xl. ,Rep Or reoacmwt Type Code Symbol Stamp NIP-Certificate of Authorization No. NIA . Expiration Date NWA Signed Date g c& . 2005 10xord ~~

Dragnm CERTIFICATE OF INSERVICE INSPECTION

1. the undersigned, holding a valid commission issued by the National Board of Bieler and Pressure Vessel Inspectors and the State or Province of Pensrlvaia and employed by HSB CT of Hartford. CT. have inspected the components described in the Owners Report duting the period M-S 4 - 1(-3 I to and state that to the best of my knox4edge and belief, the Owner has performed examinations and taken corrective measures descibed in this Owner's Report in accordance with the requirements of the ASME Code. Section XM.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shalt be liable in any manner for any personal irjury or property damage or a loss of any kind arising from or connected with this inspection.

,/v x JJ Commissions -A-, Al, " C3 f

. Westo'..*J Nagona Dogd. Stae. Prao . and Erndoseents Date /-AZ-

4._

RTL # A4.414-A Form No. 1774 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C. - I Date 1/18105 7NAn )

76 South Main Street - Akron. OH 44308 Sheet I of *1 (ADDRESS) - - -- - - - -

e a. eP to2S

2. Plant Beaver Vallev Power Station -.Unit No. 1 PAMC)

Shioningport, PA 15077 : -- 200066377 (AMORES) REPAiR ORGANTION P.O. 1_0O NO. ETC.

-3. Work Performed By Plant Engineering Yype Code Symbol Stamp NW Applicable Shinpingport. PA 15077 Authorization No. N/A

'ADDWESS)

Expiration Date _ _ I _ _I_ _

4. Identification of System Blowdown
5. (a) ApplicableConstuctionCode ANSI 831.1 19627 Edition. B1 Addenda. W/A Code Case (b) Appricable Edition of Section X Utilized for Repairs or Replacenents 1989E
6. Identification of Components Repaired or Replaced and Replacements Components Repieti.ASUE Reoae& coft Name d Named Mandacbuer. NaW Board Otd year Or Smped C-rvonery manurer Serial No. Idenifcason Bri . eplaoemer4 (S or

_ _ _ _ _NO)

Snubber Pacific-Scientific 20928 N/A WGCB-PSSP 200A__

- Replaced No Snubber Pacific-Scientific 16933 NWCPS-A Replacement No Snubber Pacific-Scientific 25736 NA WGCB-PSSP- Replaced No Snubber Pacific-Scientific 7.____

25511 De55E WGCBPSSP N/A = Replacement No

7. Description of Work Replaced snubber with spare for testincitrefurbishment purnoses.
8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure El Other E Pressure _ _ psi Test Temp. _________ "F

FORM NIS-2 (Back)

9. Remarks The snubbers were reopaced with a used snare rotated from stock. No Code Data Reports are available. The snubbers were purchased non-NF components (non-code).

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Re IIJIKIl1 I UI t conforms to the rules of the ASME Code Section Xl. Ri Repi O Replantec rOr Type Code Symbol Stamp Certificate of Authorization No. NIA Expiration Date N1.A Signed G o jw'. Dale ~ IZ-_ ti .2005 gwwor Omms Designee.r CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT. have Inspected the components described in the Owner's Report during the period 4l f. to /-;/- 1 and state that to the best of my knowledge and belief, the Owner has perfo med examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code. Section XA.

By signing this certificate neither the inspector nor his employer makes any warranty. expressed or impled. concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner or any personal "jtuy or property damage or a loss of any kind arising from or connected with this Inspection. 4 S0 j 2, Commissions 77 A' /A' "  :?

Nafiond Bomd. SOte. Proace. andt Endosemer Date t2005

RTL #A4.414-A Form No. 1775 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner F.E.N.O.C. - Date 1/18105 76 South Main Street - Akron.- OH 44308 - - Shee It I of 1 (ADORESS) -
2. Plant Beaver Valley Power Station Unit t No. 1 1 -- ---

Shipninonort. PA 15077 zUVUUVOOD (ADORESS) - REPAR ORGANZATION PMO.NO "NO, ETC.

3. Work Performed By Plant Engineerinj6 4 itype Code Symbol Stamp
  • wt Arw lAE)

Shippingport. PA 15077 , Authc orization No. N/A (ADDRESS)

Expirn3tion Date -

4. Identification of System Feedwater
5. (a) Applcable Cons"rbcion Code ANSI B31.1 ---196Z Edition. 71Addenda. I/A Code Case (b) Applicable Edition ofSecion Xl Utilized for RepaLis or Replacements 1989E
6. Identification of Components Repaired or Replaced and Replacements Components Repaied. ASAIE Replacedt Code Named Hname d Manuadurer Na~on ad - Or Year - Or Starnped Compoenti anufacuer serial. M . NM kk ation Rep a-.. (YESM r

_ _ _ _ _ __ __ _ _ _ _ _ _ _ _ _ _ _N O)

Snubber Grinnell 30460 N/A WFPD-HSS-229 - Replaced No Snubber Grinnell - 24503 N/A VWFPD-HSS-229 Replacement No

7. Description of Work Replaced snubber With spare for testinca/refurbishment purpLoses.
8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure ]

Other [] Pressure _ _ psi Test Temp. °___

F

FORM NIS-2 (Back)

9. Remarks The snubbers were replaced with a used spare rotated from stock. No Code Data ReDorts are available. The snubbers were purchased non-NF components (non-code).

CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this ReeDlacement conforms to the rules of the ASME Code Section Xi. OrRpa,.

irOr fleacnw Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date NI A Signed 1

@ r .. Jn,... dz i4sr r° Date k ig .205 i CERTIFICATE OF INSERVICE INSPECTION

1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsvyvania and employed by HSB CT of Hartford. CT. have inspected the components described in the Owner's Report during the period 4 Az G .3 to /_ /- Go . and stale that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section la.

By signing this certificate neither the inspector nor his employer makes any warranty; expressed or implied, concerning the examinations and corrective measures described in this Ownees Report. Furthermore, neither the inspector nor his employer shal be liable in any manner for any personal irjury or property damage or a loss of any kind arising from or connected with this inspection.

/92-cr, i_

J_c knpedgysisgnatte Commissions 'Asi

/ -7L 'o't National Board. Slade PHoine. and Endorsenhot Vl" Date /_ 0L /- ,2005

r RTL #A4.414-A Form No. 1776 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner F.E.N.O.C. Date 1/18/05 (NUE) 76 South Main Street - Akron. OH 44308 Sheet 1 of I (ADOEMSS) ' -'
2. Plant Beaver Valley Power Station Unit No;. 1 Shioninnnort, PA 15077 - , -- -

200066387 REPAIRORGANIZATION P.O. NO, JOBNO, ETC.

3. Work Performed By Plant Enuineering type Code Symbol Stamp Not ADiCabe Shippingport. PA 15077 Authorization No. NIA (ADORESS) . -

Expiration Date '-_

4. Identification of System Mainsteam
5. (a) AppricableConstuctionCode ANSI B31:1 19_U Edition. S7Addenda. N/A Code Case (b) Applicable Edition of Section XIUilrized for Repairs or Replacements 1989E
6. Identification of Components Repaired or Replaced and Replacements Components RPepsred. ASW

,eptabced. Code Nam of Nam of Uaradcker NaEoui Board Other Yerw Or Stamped Convne Manuladue. Serbt No. NO. ' eoskation Built Re cemen( MYES or

. .. ,: -,. .NO)

Snubber Grinnel 8333 NUA SHP-HSS-206 _ Replaced No Snubber Grinnell 8335 N/A SHP-HSS-206 _ Replacement No Snubber Grinne. 19825 WA

Replaced SHP-HSS-211 No Snubber Grinnell 19826 N/A SHP-HSS-211 _ Replacement No
7. Description of Work Replaced snubber with snare for testin.NAefurbishment Nurnoses.
8. Tests Conducted: Hydrostatic [I Pneumatic O Nominal Operating Pressure Ol Other E Pressure psi Test Temp. F

4 FORM NIS-2 (Back)

9. Remarks The snubbers were replaced with a used spare rotated from stock. No Code Data Reports are available. The snubbers were purchased non-NF components (non-code).

CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code Section Xl. 'rtepad 'Or Rmlacemd Type Code Symbol Stamp NIA.

Certificate of Authorization No. NIA Expiration Date NIA Signed JZ rŽ12e Date \IE . 2005.

CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT. have Inspected the components described in the Owners Report durng the period '9 S3 to ________ and state that to the best of my knowmedge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requtirements of the ASME Code. Section MI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Report Furtlermore. neither the inspector nor his employer shan be liable In any manner for any personal ironky or property damage or a loss of any kind arising from or connected Wvth this inspectiot

_ Commissions / /)4 Ad3 3 ?1 Ialtion Dodd. Stale. Prwce. a& Ernasemeft Date /20 / - ,2005

RTL # A4.414-A

- -: . I Form No. 1777

- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi -

1. Owner F.E.N.O.C. Date 1/18105 (No) 76 South Main Street - Akron. OH 44308 Sheet 1 of I

. e P e S .al

2. Plant Beaver Vallev Power Station Unit No. I

--Shinvingnort. PA 15077 - :

(ADORES) REPAIR ORGAITION P.O. NO. JOB NO, ETC-

3. Work Performed By Plant Engineering fype Code Symbol Stamp - Not ADQCble (su&I - - .. .

Shipoinoport. PA 15077 Authorization No. N/A (SAiOSS} I .,

Expiration Date __a___ _I__ _ _ _

4. Identification of System Residual Heat Removal
5. (a) ApplicableConstuctionCode ANSI B31.1 19§Z Edition. S71 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989E -
6. Identification of Components Repaired or Replaced and Replacements Components Repaired. AS&E

.. e.d. Code 1ame of Name i er Nora toard - Other Yea Or Staved comcera .lulaxer , Seial No. No. Buid e PWX,.

' Pdeniccaio, (YES or

_ _ _ _ _ _ _ _ _ _N O)

Snubber Grinnell 11739 NIA RH-iSS-203 _ Replaced No Snubber Grinnel 8315 N/A RH-HSS-203 Replacement No

7. Description of Work Replaced snubber With spare for testing/refurbishment purposes.
8. Tests Conducted: Hydrostatic E Pneumatic E Nominal Operating Pressure El Other El Pressure psi Test Temp. °F

i FORM NIS-2 (Back)

9. Remarks The snubbers were reotaced with a used soare rotated from stock. No Code Data ReDorts are available. The snubbers were purchased non-NF components (non-codel.

CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code Section XI. Repair Or Replacemert Type Code Symbol Stamp NIA' -

Certificate of Authorization No. NIA Expiration Date NIA Signed ._2, Date J~q-I2 2005 owrieror T-4 CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board Bofler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT. have inspected the components described in the Owner's Report during the period V- .0 - c' to Z.andstaitethatto 9-<Lz.

the best of my knowledge and belief, the O0ner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Ml.

By signing this certificale neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore. neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with ths inspectio 5 j 2/ Commissions -A A4 0e38 lnspN 6kxBore State.

5a Prm., andre Date / .2005

RTL # A4.414-A Form No. 1778 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner F.E.N.O.C. Date 1/18/05 76 South Main Street - Akron. OH 44308 Sheet 1 of I (ADDRESS)
2. Plant Beaver Vallev Power Station Unit No. 1 S NA t)

Shinvingport, PA 1 5077 ' ' ~-, 200066390 (AnISs) :REPAR ORGANVATMON P.O. NO, J" NO, ETC.

3. Work Performed By Plant Engineering type Code Symbol Stamp Shippingoort, PA 15077 Authorization No. NIA Expiration Date -
4. Identification of System. Reactor Component Cooling & Residual Heat Removal
5. (a) Applicable ConstsuctionCode ANSI B31.1 19§Z Edtion.S71 Addenda. NWA CodeCase (b) Applicable Edition of Section )OUtilized for Repairs or Replacements 1 9E-
6. Identification of Components Repaired or Replaced and Replacements Components Reparec AS&E Repte. CO&e Name o Nam & Wrifaduer Nabornl Board Mare Year . Or,-.. Saved Con"nrA Wrdached Sei No. No. Iden6fica60n UiA Relace.t Y er

._ ._ . - .NO)

Snubber Grinnell 22179 N/A CC-HSS-408 - Replaced No Snubber Grinnell 25881 NWA CC-HSS-408 - Replacement No Snubber Grinnell 9153 N/A i RH-HSS-114 = Replaced No Snubber Grinnell 8402 N/A RH-4SS-114 - Replacement 'No

7. Description of Work - Reolaced snubber with snare for lestina/refurbishment nurnoses.
8. Tests Conducted: Hydroslatic E Pneumatic OJ Nominal Operating Pressure El Other El Pressure _ _ psi Test Temp. _

F

FORM NIS-2 (Back)

9. Remarks The snubbers were replaced with a used spare rotated from stock. No Code Data Reports are available. The snubbers were purchased non-NF components (non-code).

CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this iFroad: I En lt conforms to the rules of the ASME Code Section Xl. Rep pa Or Reptacemewt Type Code Symbol Stamp NWA Certificate of Authorization No. W/A Expiration Date IJN/A Signed ' Date <1 2005

,w or 04es DoesJWe To CERTIFICATE OF INSERVICE INSPECTION

1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT. have inspected the components described in the Ownees Report during the period '-7 to- to /JO( /- 5 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning mhe

. examinations and corrective measures described in this Owner's Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

I Al~J.-J kispertroShe Commissions _____A Na n Boa.

Staie. Row". awdEndmwram Date D ate ,I ,

2/0-

.2005

RTL #A4.414-A Form No. 1779 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C. Date 1/18 /05 76 South Main Street - Akron. OH 44308 Sheet I of 1 (ADOAESS) 9 Plant Rpever Vallev Pnwer Station Unit No. 1

!Thinninnnnrt PA I sn77

_e wwvW wmvv

.  % l f f w w f .

200066391 (AM WEPAIRORGANVATION P.O. tNO- J NO, ETC.

3. Work Performed By Plant Engineering Type Code Symbol Stamp worioabie (NMAE) -N -. .--

ShivPing!Dort, PA 15077 Authorization No. N/A (ADMRESS)

Expiration Date -_ _ _-

4. Identification of System Containment Depressurization. Safety Iniection & River Water
5. (a) Applicable Consbuction Code ANSI 31.1 19fZ Edition. S71 Addenda NtA Code Case (b) Appticable Edition of Section Xl Utilized for Repairs or Replacements 1989E
6. Identification of Components Repaired or Replaced and Replacements Components Repaired. AS$4E Repbace4 Code Name of Name of Manuracurer Na.onI Board OMW Year Or Stawmed Componert Uamwiacmsrer Seii No. NM. IdenrOcafin aolt Replacemefl (YES or

.__ ._ _ _._. NO)

Snubber Grinnell 8402 N.A RS-HSS-209A _ Replaced No Snubber Grinnell 9185 N/A RS-HSS-209A _ Replacement No Snubber Gnnnell 25881 N/A SI-PSSP-010 _ Replaced No Snubber Guinnelt 8804 N/A Sl-PSSP-010 Replacement No Snubber Grinnell 8173 N/A WR-HSS-308 Replaced No Snubber Grinnell 8179 N/A WR-HSS-308 _ Replacement No

7. Description of Work Rt-ninend -,ntihh~rmwith nnarn for tnstinn~rPnfurhi-hrn~nt nnsrnnoP~r ,.
8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure El Other 0 Pressure _ _ psi Test Temp. °F

0,4 FORM NIS-2 (Back)

9. Remarks The snubbers were replaced with a used spare rotated from stock. No Code Data RePorts are available. The snubbers were purchased non-NF comPonents (non-code),

CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this Replacernent conforms to the rules of the ASME Code Section Xl. k Repqak Or Replaceffst Type Code Symbol Stamp NIAk' Certificate of Authorization No. N/A Expiration Date NIhk Signed JA Ow sOw&fJev oor Ot ,'S oe"*e. -ie 'j

. Ow-eOc Date J Ig 2005 CERTIFICATE OF INSERVICE INSPECTION 1.the undersigned, holding a varid commission issued by the National Board of Bieler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT. have inspeted the components described in the Owner's Report during the period -; 9(3 to. /-c2/ 5 - and state that to the best of my knoWLedge and befief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code. Section Xi.

By sigring this certficale neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore. neither the inspector nor his employer shal be liable in any manner for any personal irjury or property damage or a loss of any kind arising from or connected with this inspection.

,to-z, J ILX-41 bSigrnake Commissions _-Z~JO /(4 x 3 fTY Habonid Boad Stae. Pmwio-_ xWdEdoremt Date