MONTHYEARL-23-167, Twenty-Third Refueling Outage Inservice Inspection Summary Report2023-09-13013 September 2023 Twenty-Third Refueling Outage Inservice Inspection Summary Report L-23-016, Twenty-Eighth Refueling Outage Inservice Inspection Summary Report2023-02-21021 February 2023 Twenty-Eighth Refueling Outage Inservice Inspection Summary Report L-22-100, 180-Day Steam Generator Tube Inspection Report2022-05-0505 May 2022 180-Day Steam Generator Tube Inspection Report L-22-015, Twenty-Second Refueling Outage Inservice Inspection Summary Report2022-02-0707 February 2022 Twenty-Second Refueling Outage Inservice Inspection Summary Report L-21-191, Twenty-Seventh Refueling Outage Inservice Inspection Summary Report2021-08-0303 August 2021 Twenty-Seventh Refueling Outage Inservice Inspection Summary Report L-21-034, Report of Facility Changes, Tests and Experiments2021-02-23023 February 2021 Report of Facility Changes, Tests and Experiments L-20-264, 180-Day Steam Generator Tube Inspection Report2020-10-13013 October 2020 180-Day Steam Generator Tube Inspection Report L-20-156, Steam Generator Inspection Reports - Spring 2020 Refueling Outage2020-07-28028 July 2020 Steam Generator Inspection Reports - Spring 2020 Refueling Outage L-20-127, Supplement to 10 CFR 50.55a Request Number VRR4, Revision 0, Containment Isolation Valve Test Frequency2020-04-0606 April 2020 Supplement to 10 CFR 50.55a Request Number VRR4, Revision 0, Containment Isolation Valve Test Frequency L-19-107, Impractical American Society of Mechanical Engineers Boiler and Pressure Vessel Code Section XI Examination Requirements2019-08-27027 August 2019 Impractical American Society of Mechanical Engineers Boiler and Pressure Vessel Code Section XI Examination Requirements L-19-060, Attachment C: Beaver Valley, Unit 2, 2R20 Steam Generator Examination Results 2RCS-SG21C (Tubes with Service Induced Indications)2019-03-28028 March 2019 Attachment C: Beaver Valley, Unit 2, 2R20 Steam Generator Examination Results 2RCS-SG21C (Tubes with Service Induced Indications) L-19-010, Twentieth Refueling Outage Inservice Inspection Summary Report2019-01-31031 January 2019 Twentieth Refueling Outage Inservice Inspection Summary Report L-18-176, Twenty-Fifth Refueling Outage Inservice Inspection Summary Report2018-07-23023 July 2018 Twenty-Fifth Refueling Outage Inservice Inspection Summary Report L-18-107, Submittal of Snubber Program for Beaver Valley Power Station, Units Nos. 1 and 22018-06-0707 June 2018 Submittal of Snubber Program for Beaver Valley Power Station, Units Nos. 1 and 2 L-17-294, Submittal of 180-Day Steam Generator Tube Inspection Report - Technical Specification 5.6.6.22017-10-17017 October 2017 Submittal of 180-Day Steam Generator Tube Inspection Report - Technical Specification 5.6.6.2 L-17-298, Submittal of the 10-Year Interval Inservice Testing Programs2017-10-10010 October 2017 Submittal of the 10-Year Interval Inservice Testing Programs CNS-17-044, Inservice Inspection Report for Unit 1 End of Cycle 23 Refueling Outage2017-08-21021 August 2017 Inservice Inspection Report for Unit 1 End of Cycle 23 Refueling Outage L-17-240, Nineteenth Refueling Outage Lnservice Inspection Summary Report2017-08-18018 August 2017 Nineteenth Refueling Outage Lnservice Inspection Summary Report L-17-074, Steam Generator Inspection Reports - Spring 2017 Refueling Outage2017-08-0808 August 2017 Steam Generator Inspection Reports - Spring 2017 Refueling Outage ML17013A5872017-01-13013 January 2017 Twenty-Fourth Refueling Outage Inspection Summary Report L-16-241, Updated Steam Generator Inspection Report - Fall 2015 Refueling Outage2016-10-11011 October 2016 Updated Steam Generator Inspection Report - Fall 2015 Refueling Outage L-16-019, Eighteenth Refueling Outage Lnservice Inspection Summary Report2016-01-22022 January 2016 Eighteenth Refueling Outage Lnservice Inspection Summary Report L-16-022, Steam Generator Inspection Reports - Fall 2015 Refueling Outage2016-01-22022 January 2016 Steam Generator Inspection Reports - Fall 2015 Refueling Outage L-15-200, Twenty-Third Refueling Outage Inservice Inspection Report2015-08-18018 August 2015 Twenty-Third Refueling Outage Inservice Inspection Report L-14-243, Seventeenth Refueling Outage Inservice Inspection Summary Report2014-08-20020 August 2014 Seventeenth Refueling Outage Inservice Inspection Summary Report ML14034A1082014-01-30030 January 2014 Twenty-Second Refueling Outage Inservice Inspection Report L-13-058, Steam Generator Inspection Report - Technical Specification 5.6.6.2.12013-04-23023 April 2013 Steam Generator Inspection Report - Technical Specification 5.6.6.2.1 L-13-027, Sixteenth Refueling Outage Inservice Inspection Summary Report2013-02-0101 February 2013 Sixteenth Refueling Outage Inservice Inspection Summary Report L-12-419, Submittal of Twenty-First Refueling Outage Inservice Inspection Report Revision2012-12-28028 December 2012 Submittal of Twenty-First Refueling Outage Inservice Inspection Report Revision L-12-206, Twenty-First Refueling Outage Inservice Inspection Report2012-08-0808 August 2012 Twenty-First Refueling Outage Inservice Inspection Report L-11-182, Fifteenth Refueling Outage Inservice Inspection Report2011-07-0505 July 2011 Fifteenth Refueling Outage Inservice Inspection Report L-11-002, Twentieth Refueling Outage Inservice Inspection Report2011-01-31031 January 2011 Twentieth Refueling Outage Inservice Inspection Report L-10-020, Fourteenth Refueling Outage Inservice Inspection Report2010-02-22022 February 2010 Fourteenth Refueling Outage Inservice Inspection Report L-09-203, Nineteenth Refueling Outage Inservice Inspection Report for April 1, 2008 to May 21, 20092009-08-18018 August 2009 Nineteenth Refueling Outage Inservice Inspection Report for April 1, 2008 to May 21, 2009 L-08-339, Impractical American Society of Mechanical Engineers Code Section XI Weld Examination Requirements2008-11-26026 November 2008 Impractical American Society of Mechanical Engineers Code Section XI Weld Examination Requirements L-08-265, Thirteenth Refueling Outage Inservice Inspection Report2008-08-18018 August 2008 Thirteenth Refueling Outage Inservice Inspection Report ML0802500602008-01-21021 January 2008 Eighteenth Refueling Outage Inservice Inspection Report L-07-147, Supplemental Information in Support of ASME Code Relief Request PRR62007-11-14014 November 2007 Supplemental Information in Support of ASME Code Relief Request PRR6 ML0713703472007-05-11011 May 2007 Proposed Alternatives and Relief Requests Associated with the Inservice Testing Program Ten-Year Update L-07-023, Twelfth Refueling Outage Inservice Inspection Report2007-02-0202 February 2007 Twelfth Refueling Outage Inservice Inspection Report L-06-104, Seventeenth Refueling Outage Inservice Inspection Report2006-07-14014 July 2006 Seventeenth Refueling Outage Inservice Inspection Report L-05-164, Proposed Alternative to American Society of Mechanical Engineers Code Section XI Visual Examination Requirements Associated with Third Ten-Year Interval Inservice Inspection Program2005-10-31031 October 2005 Proposed Alternative to American Society of Mechanical Engineers Code Section XI Visual Examination Requirements Associated with Third Ten-Year Interval Inservice Inspection Program L-05-030, Sixteenth Refueling Outage Inservice Inspection Report2005-02-10010 February 2005 Sixteenth Refueling Outage Inservice Inspection Report L-05-014, Inservice Testing Programs, Proposed Revisions 1M and 2J2005-02-0404 February 2005 Inservice Testing Programs, Proposed Revisions 1M and 2J L-04-117, Inservice Testing Program, Proposed Revision 1L2004-09-0303 September 2004 Inservice Testing Program, Proposed Revision 1L L-04-100, No. 2, Inservice Testing Programs, Proposed Revisions 1K and 2I, Addenda 12004-07-0909 July 2004 No. 2, Inservice Testing Programs, Proposed Revisions 1K and 2I, Addenda 1 L-04-066, Inservice Testing Programs, Proposed Revisions 1K and 2I2004-05-21021 May 2004 Inservice Testing Programs, Proposed Revisions 1K and 2I L-04-033, Inservice Inspection Programs, Proposed Revisions 1J and 2H2004-03-12012 March 2004 Inservice Inspection Programs, Proposed Revisions 1J and 2H L-04-029, Year 2003 Steam Generator Examination Reports2004-03-0404 March 2004 Year 2003 Steam Generator Examination Reports L-03-217, Tenth Refueling Outage Inservice Inspection Report2003-12-30030 December 2003 Tenth Refueling Outage Inservice Inspection Report 2023-09-13
[Table view] Category:Letter type:L
MONTHYEARL-23-267, Submittal of Discharge Monitoring Report (Npdes), Permit No. PA00256152023-12-18018 December 2023 Submittal of Discharge Monitoring Report (Npdes), Permit No. PA0025615 L-23-229, Request for Additional Information Regarding the Spring 2023 Generic Letter 95-05 Voltage-Based Alternate Repair Criteria and Steam Generator F-Star Reports2023-11-29029 November 2023 Request for Additional Information Regarding the Spring 2023 Generic Letter 95-05 Voltage-Based Alternate Repair Criteria and Steam Generator F-Star Reports L-23-247, Discharge Monitoring Report (NPDES) Permit No. PA00256152023-11-17017 November 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-23-227, Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Third Quarter 20232023-10-20020 October 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Third Quarter 2023 L-23-208, Submittal of Discharge Monitoring Report Cnpdes), Permit No. PA00256152023-09-14014 September 2023 Submittal of Discharge Monitoring Report Cnpdes), Permit No. PA0025615 L-23-167, Twenty-Third Refueling Outage Inservice Inspection Summary Report2023-09-13013 September 2023 Twenty-Third Refueling Outage Inservice Inspection Summary Report L-23-205, Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments2023-09-12012 September 2023 Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments L-23-172, Quality Assurance Program Manual2023-08-31031 August 2023 Quality Assurance Program Manual L-23-188, Energy Harbor Nuclear Corp., Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments2023-08-0707 August 2023 Energy Harbor Nuclear Corp., Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments L-23-179, Submittal of Discharge Monitoring Report, (NPDES) Permit No. PA00256152023-07-18018 July 2023 Submittal of Discharge Monitoring Report, (NPDES) Permit No. PA0025615 L-23-165, Discharge Monitoring Report (NPDES) Permit No. PA00256152023-06-26026 June 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-23-139, Response to Request for Additional Information Regarding Fall 2022 180-Day Steam Generator Tube Inspection Report2023-06-13013 June 2023 Response to Request for Additional Information Regarding Fall 2022 180-Day Steam Generator Tube Inspection Report L-23-055, Submittal of the Updated Final Safety Analysis Report, Revision 342023-05-23023 May 2023 Submittal of the Updated Final Safety Analysis Report, Revision 34 L-23-065, Annual Financial Report2023-05-22022 May 2023 Annual Financial Report L-23-137, Discharge Monitoring Report (NPDES) Permit No. PA00256152023-05-18018 May 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-23-125, Cycle 24 Core Operating Limits Report2023-05-17017 May 2023 Cycle 24 Core Operating Limits Report L-23-132, Response to NRC Regulatory Issue Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations2023-05-10010 May 2023 Response to NRC Regulatory Issue Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations L-23-129, Response to Request for Additional Information for 10 CFR 50.55a Request 2-TYP-4-RV-06 for Alternative Repair Methods for Reactor Pressure Vessel Head Penetrations2023-05-0505 May 2023 Response to Request for Additional Information for 10 CFR 50.55a Request 2-TYP-4-RV-06 for Alternative Repair Methods for Reactor Pressure Vessel Head Penetrations L-23-115, Submittal of 2022 Annual Radioactive Effluent Release Report, 2022 Annual Radiological Environmental Operating Report, and 2022 Annual Environmental Operating Report (Non-Radiological2023-04-27027 April 2023 Submittal of 2022 Annual Radioactive Effluent Release Report, 2022 Annual Radiological Environmental Operating Report, and 2022 Annual Environmental Operating Report (Non-Radiological L-23-126, Discharge Monitoring Report (Npdes), Permit No. PA00256152023-04-22022 April 2023 Discharge Monitoring Report (Npdes), Permit No. PA0025615 L-23-053, 2022 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models2023-04-14014 April 2023 2022 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models L-23-061, Submittal of the Decommissioning Funding Status Reports2023-03-31031 March 2023 Submittal of the Decommissioning Funding Status Reports L-23-058, 180-Day Steam Generator Tube Inspection Report2023-03-27027 March 2023 180-Day Steam Generator Tube Inspection Report L-23-066, Annual Notification of Property Insurance Coverage2023-03-21021 March 2023 Annual Notification of Property Insurance Coverage L-23-036, Report of Facility Changes, Tests and Experiments2023-03-13013 March 2023 Report of Facility Changes, Tests and Experiments L-23-086, Response to Request for Additional Information for Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair2023-03-0404 March 2023 Response to Request for Additional Information for Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair L-23-087, Supplement to Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair (L-2023-LLA-0027)2023-03-0404 March 2023 Supplement to Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair (L-2023-LLA-0027) L-23-073, Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair2023-03-0101 March 2023 Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair L-23-016, Twenty-Eighth Refueling Outage Inservice Inspection Summary Report2023-02-21021 February 2023 Twenty-Eighth Refueling Outage Inservice Inspection Summary Report L-23-064, Discharge Monitoring Report, (NPDES) Permit No. PA00256152023-02-21021 February 2023 Discharge Monitoring Report, (NPDES) Permit No. PA0025615 L-23-057, Energy Harbor Nuclear Corp Retrospective Premium Guarantee2023-02-20020 February 2023 Energy Harbor Nuclear Corp Retrospective Premium Guarantee L-22-193, Request for Exemption from Specific Provisions in 10 CFR 50 Appendix H2023-02-14014 February 2023 Request for Exemption from Specific Provisions in 10 CFR 50 Appendix H L-22-286, Supplement to Request for an Amendment to Consolidate Fuel Decay Time Technical Specifications in a New Limiting Condition for Operation Titled Decay Time2023-02-14014 February 2023 Supplement to Request for an Amendment to Consolidate Fuel Decay Time Technical Specifications in a New Limiting Condition for Operation Titled Decay Time L-23-032, Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Second Half of 20222023-01-23023 January 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Second Half of 2022 L-22-281, Discharge Monitoring Report (NPDES) Permit No. PA00256152022-12-16016 December 2022 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-246, Response to Request for Additional Information Regarding a Request to Consolidate Fuel Decay Time Technical Specifications to New LCO2022-12-0707 December 2022 Response to Request for Additional Information Regarding a Request to Consolidate Fuel Decay Time Technical Specifications to New LCO L-22-217, Submittal of Discharge Monitoring Report (NPDES) Permit No. PA00256152022-11-21021 November 2022 Submittal of Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-226, Emergency Preparedness Plan2022-11-0404 November 2022 Emergency Preparedness Plan L-22-222, Cycle 29-1 Core Operating Limits Report2022-10-31031 October 2022 Cycle 29-1 Core Operating Limits Report L-22-228, Independent Spent Fuel Storage Installation Changes, Tests, and Experiments2022-10-26026 October 2022 Independent Spent Fuel Storage Installation Changes, Tests, and Experiments L-22-200, Response to Request for Additional Information Regarding a 180-Day Steam Generator Tube Inspection Report Fall 2021 Refueling Outage2022-10-21021 October 2022 Response to Request for Additional Information Regarding a 180-Day Steam Generator Tube Inspection Report Fall 2021 Refueling Outage L-22-232, Withdrawal of a License Amendment Request Associated with Fire Protection Program Changes2022-10-21021 October 2022 Withdrawal of a License Amendment Request Associated with Fire Protection Program Changes L-22-238, Submittal of Discharge Monitoring Report (NPDES) Permit No. PA00256152022-10-20020 October 2022 Submittal of Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-227, Revised August 2022 Outfall 003 & 004 NPDES Discharge Monitoring Report (Dmr), Revised Daily Effluent Monitoring Report Forms for Outfalls 003 & 004 and Corrective Action Letter from Eurofins2022-10-0303 October 2022 Revised August 2022 Outfall 003 & 004 NPDES Discharge Monitoring Report (Dmr), Revised Daily Effluent Monitoring Report Forms for Outfalls 003 & 004 and Corrective Action Letter from Eurofins L-22-219, Submittal of Discharge Monitoring Report (NPDES) Permit No. PA00256152022-09-26026 September 2022 Submittal of Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-204, Submittal of Evacuation Time Estimates2022-09-0707 September 2022 Submittal of Evacuation Time Estimates L-22-137, Request for Fire Protection Program Changes2022-09-0606 September 2022 Request for Fire Protection Program Changes L-21-238, License Amendment Request for Addition of Analytical Methodology to the Core Operating Limits Report for a Full Spectrum Loss of Coolant Accident2022-08-31031 August 2022 License Amendment Request for Addition of Analytical Methodology to the Core Operating Limits Report for a Full Spectrum Loss of Coolant Accident L-22-188, Response to Request for Additional Information Regarding Steam Generator Inspection Report- Fall 2021 Refueling Outage2022-08-22022 August 2022 Response to Request for Additional Information Regarding Steam Generator Inspection Report- Fall 2021 Refueling Outage L-22-191, Spent Fuel Storage Cask Registration2022-08-17017 August 2022 Spent Fuel Storage Cask Registration 2023-09-14
[Table view] |
Text
energy Energy Harbor Nuclear Corp.
harbor Beaver Valley Power Station P.O. Box 4 Shippingport, PA 15077 Barry N. Blair 724-682-5234 Site Vice President, Beaver Valley Nuclear February 21, 2023 L-23-016 10 CFR 50.55a(g)
ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
Subject:
Beaver Valley Power Station, Unit No. 1 Docket No. 50-334, License No. DPR-66 Twenty-Eighth Refueling Outage lnservice Inspection Summary Report In accordance with 10 CFR 50.55a, "Codes and Standards," and the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) Case N-532-5, "Repair/Replacement Activity Documentation Requirements and lnservice Inspection Summary Report Preparation and Submission,Section XI, Division 1," enclosed pleased find the inservice inspection owner's activity report for examinations performed prior to and during the twenty-eighth refueling outage at Beaver Valley Power Station, Unit No. 1 (BVPS-1 ).
lnservice inspection activities addressed in the report were performed during the second period of the fifth ten-year interval in accordance with Section XI of the ASME Code, 2013 Edition. The inservice inspection term at BVPS-1 covered by this report includes the period from May 12, 2021 to November 18, 2022.
There are no regulatory commitments contained in this submittal. If there are any questions or if additional information is required, please contact Mr. Phil H. Lashley, Manager - Fleet Licensing, at (330) 696-7208.
Barry N. Blair
Beaver Valley Power Station, Unit No. 1 L-23-016 Page 2
Enclosure:
Beaver Valley Power Station, Unit No. 1, Twenty-Eighth Refueling Outage Inservice Inspection Owners Activity Report cc: NRC Region I Administrator NRC Resident Inspector NRR Project Manager Director BRP/DEP Site BRP/DEP Representative
Enclosure L-23-016 Beaver Valley Power Station, Unit No. 1 Twenty-Eighth Refueling Outage Inservice Inspection Owner's Activity Report (2 pages follow)
Beaver Valley Power Station Unit 1 energy Report No. BV1-OAR 1-1 R28 lnservice Inspection Program 1R28 Owner's Activity Report harbor 1 of 2 FORM OAR-1 OWNER'S ACJIYIIY REPORT Report Number BV1-OAR1-1R28 Plant Beaver Valley Power Station Unit No. Commercial Service Date September 30, 1976 Refueling Outage No. 1R28 (if applicable)
Current Inspection Interval 5th (1st, 2nd, 3"', 4th, other)
Current Inspection Period Edition and Addenda of Section XI applicable to the inspection plan 2013 Edition Date and Revision of inspection plans October 11, 2021, 1/2-ADM-2039, Rev. 19 Edition and Addenda of Section XI applicable to repair/replacement activities, if ~ifferent than the inspection plans _S_am_e_ _ _ _ __
Code Case Used: N-513-4, N-532-5, N-639, N-661-3, and N-716-1 (if applicable, including cases modified by Case N-532 and later revisions)
CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations supporting completion of 1R28 (refueling outage number)
Signed L. Seaman-ISi Program Owner Date 61/-;;.r;/g 3 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by Hartford Steam Boiler of Hartford, have inspected the items described in the Inspection and Insurance Connecticut Company Owner's Activity Report, and state that, to the best ofmy knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the Inspector nor his employer shall be liable i anner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
NB 15908 NIR (National Board Number and Endorsement)
Beaver Valley Power Station Unit 1 energy Report No. BV1-0AR 1-1 R28 lnservice Inspection Program 1R28 Owner's Activity Report harbor 2 of2 TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category Item Description Evaluation Description and Item Number 0-8 02.10 24"-WR20-151-Q3 24 inch class 3 River water piping . A Code Case 513-4 evaluation was performed to continue operation into outaoe 1R28 when the pipinQ was repaired .
D-8 02.10 20"-WR-5-151-Q3 Class 3 River water piping reducer. A Code Case 513-4 evaluation was performed to continue operation into outage 1R28 when the pipinQ was repaired.
TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Code Date Repair/Replacement Class Item Description Description of Work Completed Plan Number 3 24" WR20-151-Q3 Pipeline repaired. 11-15-22 4404 Applied Code case 661-3 overlays in two 3 20"-WR-5-151-Q3 11-4-2022 4422 locations.
Notes:
(1) "Date Completed" is the date that the Repair Replacement Plan final signature was applied. This date may be after the end of the reporting period for work that was physically completed within the reporting period.
(2) Steam Generator activities are reported under separate correspondence in Technical Specification required reports.