ENOC

-Beaver Valley Power Station FC P.O. Box 4 Shippingport, PA 15077 FirstEnergy Nuclear Operating Company Eric A. Larson 724-682-5234 Site Vice President Fax. 724-643-8069 January 30, 2014 L-14-030 10 CFR 50.55a ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

Beaver Valley Power Station, Unit No. 1 Docket No. 50-334, License No. DPR-66 Twenty-Second Refueling Outage Inservice Inspection Report Enclosed please find the Inservice Inspection (ISI) Summary Report on American Society of Mechanical Engineers (ASME) Class 1, 2, 3, and Subsection IWE examinations performed prior to and during the twenty-second refueling outage at Beaver Valley Power Station, Unit No. 1 (BVPS-1). The ASME Boiler and Pressure Vessel Code,Section XI, Article IWA-6240 requires an inservice inspection summary report to be submitted to the enforcement and regulatory authorities having jurisdiction at the plant site within ninety days after completion of each refueling outage. The recent inservice inspection term at BVPS-1 covered the period from May 12, 2012 to November 4, 2013.

The Class 1, 2, 3, and Subsection IWE examinations are part of Interval 4, Period 2 of the BVPS-1 ISI schedule and were performed in accordance with Section XI of the ASME Boiler and Pressure Vessel Code, 2001 Edition, 2003 Addenda.

There are no regulatory commitments contained in this letter. If there are any questions or if additional information is required, please contact Mr. Thomas A. Lentz, Manager -

Fleet Licensing, at 330-315-6810.

Sincerely, Eric A. Larson

Beaver Valley Power Station, Unit No. 1 L-14-030 Page 2

Enclosure:

FirstEnergy Nuclear Operating Company, Beaver Valley Power Station Unit 1, Twenty-Second Refueling Outage Inservice Inspection Report cc: NRC Region I Administrator NRC Resident Inspector NRC Project Manager Director BRP/DEP Site BRP/DEP Representative

FirstEnergy Nuclear Operating Company Beaver Valley Power Station Unit I Twenty-Second Refueling Outage Inservice Inspection Report

BEAVER VALLEY POWER STATION UNIT 1 Route 168, Shippingport, PA Outage 22, Year 2013 Inspection Term: 5/12/2012 to 11/4/2013 Issue date:

Owner: FirstEnergy Nuclear Operating Company (FENOC) 76 South Main St.

Akron, OH 44308 NRC Docket Number: 50-334 Reactor Supplier: Westinghouse Electric Corporation Commercial Service Date: September 30, 1976 Reviewed by:

Reviewed by:

Approved by:

Supv, Nuclear Programs ANIl Manager, Technical Services Engineering Date:

i ii Date:

//-//

Date:

//

I

90-DAY REPORT TABLE OF CONTENTS Item Page Number Cover Page 1

Table of Contents 2

Form NIS-1 3-4 Outage Summary 5

ASME XI Vessel, Piping and Support Examinations

1. Class 1 5
2. Class 2 5
3. Class 3 5
4. IWE 5

IWE Examinations 6

Pressure Testing 6

Deficiency Resolution 6

NIS-2 Forms 6

Appendix I - Completed Code Examinations Al-I thru AI-4 Appendix II - Repair/Replacement Abstract and NIS-2 Forms 2

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules I. Owner FirstEnergy I

2. Plant Beaver Valle
3. Plant Unit 1
5. Commercial Service Date Nu ey iclear Operating Company (FENOC), 76 South Main St. Akron, OH 44308 (Name and Address of Owner)

Power Station, P.O. Box 4, Shippingport, PA, 15077 (Name and Address of Plant)

4. Owner Certificate of Authorization (if required)

N/A 9/30/76

6. National Board Number for Unit N/A
7. Components Inspected Manufacturer or Component or Manufacturer or Installer State or National Appurtenance Installer Serial No.

Province No.

Board No.

Reactor Vessel Combustion Engineering 69103 105642B 21011 Pressurizer Westinghouse 1311 434676V 68-50 IC Steam Generator Westinghouse NP030651/3MB2 591603V 84 Reactor Coolant Piping Southwest Fabricating N/A N/A N/A Auxiliary Piping Schneider Power N/A N/A N/A Component Supports Various N/A N/A N/A Containment N/A N/A 4630 N/A Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8Y. in. x II in.,

(2) information in items I though 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (E0029) may be obtained from the ASME Order Dept., 22 Law Drive, Box 2300, Fairfield, NJ 07008-2300 3

FORM NIS-1 (Back)

8. Examination Dates 5/12/2012 to 11/4/2013
9. Inspection Period Identification:

8/2/2011 to 12/2/2014 ( 2nd Inspection Period of 4th Interval)

10. Inspection Interval Identification:

4/1/2008 to 3/31/2018 (4th 10-yr Inspection Interval)

11. Applicable Edition of Section XI 2001 Addenda 2003
12. Date/Revision of Inspection Plan:

1/2-ADM-2039, Revision 13

13. Abstract of Examination and Tests. Include a list.of examinations and tests and a statement concerning status of work required for the Inspection Plan. See Appendix I (Code Exams) for exams performed during 1 R22. 1 R22 was the second nd th nd outage in the 2 Period of the 4 Ten-Year Interval. The 2 Period ASME Xl examination percentage requirements have been fulfilled.
14. Abstract of Results of Examination and Tests. See text of summary report.
15. Abstract of Corrective Measures. Corrective measures were required based on an UNSAT visual exam of the bolting on the containment equipment hatch emergency airlock. One missing cotter pin and one broken cotter pin were replaced. Boric Acid accumulations reported during the outage were evaluated and resolved based on the Boric Acid Program requirements. A coatings program examination found a blister on the containment liner.

Subsequent examinations disovered a through-wall hole under the blister. Extent of condition examinations found a second hole in close proximity to the original blister. The liner plate was repaired and tested in accordance with the ASME Xl RepairlReplacement Program.

We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section Xl.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A Date b-\\-

Signed FirstEnergy Nuclear Operating By,,.

Q,*

1

_Company (FENOC)

(Owner)

/

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Connecticut have inspected the components described in this Owner's Report during the period 5/12/2012 to 11/4/2013 and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer make any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

S.Commissions NB 9428 ANIB, PA 2384 Inspector's ý#ature National Board, State, Province and Endorsements Date

/V/

V 4

OUTAGE

SUMMARY

During the Twenty-second Refueling Outage (1R22) at the Beaver Valley Power Station Unit 1, Inservice Inspection (ISI) examinations were performed on Class 1, 2, 3 and the containment liner components. This was the second outage in the second period of the fourth ten-year interval.

ASME XI Class 1, 2, 3 and IWE Credited Exams (See Appendix I)

1. Eighty-five (85) Class 1 exams were performed and are divided as follows:
a. Welds (vessels, piping, and attachments)

Ultrasonic Exams 9

Surface Exams 5

Visual Exams 4

b. Class 1 bolting Visual Exams 36
c. Visual Examinations (VT-3)

Pipe Supports 25

d. RI-ISI piping VT-2 Exams 6
2. Thirty-five (35) Class 2 exams were performed and are divided as follows:
a. Welds (vessels, pumps, piping, and attachments)

Ultrasonic Exams 7

Surface Exams 2

b. Visual Examinations (VT-3)

Pipe Supports 4

c. RI-ISI piping VT-2 exams 22
3. Five (5) visual exams of Class 3 components were performed and are divided as follows:
a. Supports, visual exams 4
b. Attachments, visual exam 1
4. Eleven (11) IWE exams were performed as follows:
a. Equipment Hatch boltings (VT-1) -

1

b. Liner UTT exam followup 1
c. Emergent Liner visual exam 1
d. Extent of condition exams (UTT) -

8 Examinations were performed by FirstEnergy Nuclear Operating Company (FENOC) NDE Technicians, supplemented with contracted NDE technicians from IDDEAL Concepts, International Quality Consultants (IQC), and Wesdyne. Appendix I compiles the examinations that have been credited toward fulfilling the Ten-Year Plan requirements.

5

IWE Examinations The IWE general visual examination was not scheduled during 1 R22. However, the coatings program examination of the containment liner reported a paint blister that was eventually found to be a through wall hole. Examination of the surrounding area found lower than nominal thickness measurements and a second through wall hole approximately 8 inches from the original hole. These examinations were supplemented with a 100 percent general visual examination of the accessible areas of the liner plate, penetrations, and moisture barrier and 8 one-square foot area thickness examinations located at the through wall hole elevation at different areas around the circumference of the liner. No other degraded areas were identified by these examinations.

Pressure Testing The Class 1 piping System Leakage Test was performed prior to plant start-up from 1 R22. All Class 1 bolted connections associated with insulated components were examined during 1 R22. Also, Class 2 and 3 system functional and system inservice tests were performed in accordance with 40-month pressure testing requirements.

Deficiency Resolution The deficiency associated with the 1 R22 VT examination on the bolting for the equipment hatch emergency airlock was documented and resolved on Condition Report 2013-16709. Two cotter pins were replaced.

The containment liner degradation was evaluated and resolved on Condition Report 2013-15843. The portion of the liner plate containing the holes was replaced and tested in accordance with the ASME XI Repair/Replacement Program.

NIS-2 Forms Included as Appendix II are the NIS-2 Forms associated with ASME XI repairs and replacements performed since the last 90-Day ISI Summary Report.

6

APPENDIX I 1 R22 COMPLETED CODE EXAMS SummaryNo 007400 008400 008900 010000 010400 012900 033350 036750 040050 042300 068100 087700 094800 098300 098400 100010 100012 100013 100014 100015 100016 100017 100018 100019 100020 100021 100022 100023 100024 100025 100026 100030 100031 100032 100033 100034 Component ID CH-140-PS-20 CH-140-PS-24 CH-140-PS-27 CH-142-PS-18 CH-142-PS-16 CH-142-PS-7 CH-102 CH-103 CH-104 CH-126-R-213 PS-244-VS-1 RC-72-R-10 RC-105-SH-41 RC-99-1 -A-03 RC-99-SH-52 BC-MOV-1 RH-700 BC-FE-1 RC-480 BC-FE-1 RC-481 BC-FE-1 RC-482 BC-MOV-1 RC-590 BC-MOV-1 RC-591 BC-MOV-1 RC-592 BC-MOV-1 RC-593 BC-MOV-1 RC-594 BC-MOV-iRC-595 BC-SI-20 BC-i SI-21 BC-iSI-22 BC-iSI-23 BC-1 SI-24 BC-iSI-25 BC-LCV-iCH-460A BC-LCV-1 CH-460B BC-iCH-32 BC-RC-E-1A-Pri Manways BC-RC-E-i B-Pri Manways Description SUPPORT SUPPORT SUPPORT SUPPORT SUPPORT SUPPORT RI-ISI SEGMENT RI-ISI SEGMENT RI-ISI SEGMENT SUPPORT SNUBBER SUPPORT SUPPORT WELDED ATT SUPPORT SH-52 SUPPORT BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION

.BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION Class 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 I

1 1

1 1

1 I

,1

,1 I

1 1

1 1

1 Category F-A F-A F-A F-A F-A F-A R-A R-A R-A F-A F-A F-A F-A B-K F-A Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon.

Boltcon BoItcon Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon Item Fl.10R Fl.10A FI.OR FI.0R FIlOR Fl. 1 OR R1.12 R1.12 R1.12 Fl.1OR FIlON FI.OR FI.10S B10.20 FI.10S Bolt1 Boltd Bolti Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Method VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 VT-2 VT-2 VT-2 VT-3 VT-3 VT-3 VT-3 PT VT-3 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 ISO 0191A-5 0191A-5 0191A-5 0191A-5 0191A-5 0191A-5 0246A-3 0247A-3 0248A-3 0253A-4 0244A-2 0348D-1 0350A-4 0350B-3 0350B-3 074A-3 0354A-1 0354B-1 0354C-1 L-00 1A-5 L-001A-5 L-002A-5 L-002A-5 L-003A-5 L-003A-5 0222B-5 0220C-5 0223B-5 0375E-5 0375F-7 0375C-5 0242A-3 0242A-3 0253A-4 E-001N E-001N Status C

C C

C C

C B

B B

C C

C.

C C

B B

B B

B B

B B

B B

B B

B B

B B

B B

B B

B Page AI-1

APPENDIX I 1R22 COMPLETED CODE EXAMS Summary No Component ID Description Class Category 100035 100038 100039 100040 100052 100053 100054 100055 100056 100057 100058 100059 100060 100061 100062 130950 133050 135050 141800 151050 162000 191800 192100 192500 193100 193150 263600 274200 274300 283800 283900 284300 289310 289600 289900 290000 BC-RC-E-1C-Pri Manways BC-1SI-51 BC-i SI-52 BC-1 SI-53 BC-RV-1 RC-551A BC-RV-1 RC-551 B BC-RV-1RC-551C BC-MOV-1 RC-535 BC-MOV-1 RC-536 BC-MOV-1 RC-537 BC-PCV-1 RC-456 BC-PCV-1 RC-455C BC-PCV-1 RC-455D BC-PZR Manway bolts BC-RV Main Fig Bolts RC-026 RC-027 RC-028 RC-75-PS-3 1RV-BMI-PENE-OD RC-R-1-ACC-INT RC-TK-1-L-1 RC-TK-1-C-4 RC-TK-1-C-8 RC-TK-1-RADIUS-6 RC-TK-1-HTR-SLEEVES DLW-LOOP2-5-S-01 RH-23-1-HSS-123 RH-23-1-HSS-124 SI-121-2-A-02 SI-121-RH-3 SI-121-R-4 SI-101-LST-110 SI-101-SH-11 SI-101-3B-A-07 TO 10 SI-101-R-24 BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION BOLTED CONNECTION RI-ISI SEGMENT RI-ISI SEGMENT RI-ISI SEGMENT SUPPORT RV LOWER HEAD BMI NOZZLES INTERIOR LONGITUDINAL WELD CIRCUMFERENTIAL WELD SKIRT CIRC WELD NOZZLE INSIDE RADIUS PZR HEATER SLEEVE BUTT WELD SNUBBER SNUBBER WELDED ATT SUPPORT RH-3 SUPPORT SUPPORT SUPPORT SUPPORT WELDED ATT SUPPORT R-24 SUPPORT Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon Boltcon R-A R-A R-A F-A N-722 B-N-1 B-B B-B B-K B-D WCAP R-A F-A F-A B-K F-A F-A F-A F-A B-K F-A T T Item Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt1 Bolt!

Bolt1 Boltd Bolt1 R1.12 R1.12 R1.12 FI.10R B15.80 B13.10 B2.12 B2.11 B10.10 B3.120 0G09140 R1.11 FI.10N FI.10N B10.20 FI.10H F1.10R FI.10L-FI.10S B1 0.20 F1.10R VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-3 VE VT-3 UT UT UT VT-2 VT-2 UT VT-3 VT-3 PT VT-3 VT-3 VT-3 VT-3 PT VT-3 E-001N 0106A-5 0107B-3 0108B-5 0350B-3 0350B-3 0350B-3 0350A-3 0350A-3 0350A-3 0350A-3 0350A-3 0350A-3 E-001 P-3 E-001 L-1 0354A-1 0354B-1 0354C-1 0379A-2 E-001 D-2 E-001F-3 E-001P-3 E-001 P-3 E-001P-3 E-001P-3 E-001P-3 L-002A-5 0107A-4 0107A-4 01 06A-5 0106A-5 0106A-5 0107A-4 0107A-4 0107A-4 0107A-4 Method Iso Status Page AI-2

APPENDIX I 1R22 COMPLETED CODE EXAMS SummaryNo 290100 290210 321200 332900 333400 334500 335700 364000 940010 940110 940120 940130 940140 381500 397750 406200 410600 412200 420150 420250 422650 422750 425050 425250 436050 440050 443850 470350 496950 509250 648000 648100 688700 697500 697550 699850 Component ID SI-101-3B-A-11 TO 12 SI-101-LST-108 SI-74-5-HSS-422 SI-22-R-PS-18 SI-22-R-PS-15 SI-22-R-PS-9 SI-22-R-PS-2 RVCH-LUG-B RC-41-1502-Q1 SI-247-1502-Q1 SI-260-1502-Ql S1-261-1502-Ql SI-262-1502-Ql P11-G-PSSP-36A SI-051A SI-85-3-A-02 SI-87-PS-09 SI-87-PS-16 CH-021 C CH-021 B CH-020B CH-020C CH-019B CH-019C CH-121 CH-122 CH-123 CH-130 SI-062B CH-028 SI-30-1-A-01 TO 04 SI-30-SH-57A RC-E-1 C-C-8 RH-12-1-S-06 RH-12-1-L-37 RH-4-3-L-21 Descrintion Class Cateaory Item Method Iso Status WELDED ATT LST-108 SUPPORT SNUBBER SUPPORT SUPPORT SUPPORT SUPPORT RV HEAD LIFTING LUG SOCKET WELDED DRAIN LINE VERT UPWARD LINE VERT UPWARD LINE VERT UPWARD LINE VERT UPWARD LINE SNUBBER RI-ISI SEGMENT WELDED ATT SUPPORT PS-R-17 SUPPORT SUPPORT RI-ISI SEGMENT RI-ISI SEGMENT RI-ISI SEGMENT RI-ISI SEGMENT RI-ISI SEGMENT RI-ISI SEGMENT RI-ISI SEGMENT RI-ISI SEGMENT RI-ISI SEGMENT RI-ISI SEGMENT RI-ISI SEGMENT RI-ISI SEGMENT WELDED ATT SUPPORT SH-57A SUPPORT CIRCUMFERENTIAL BUTT WELD PIPE WELD LONGITUDINAL WELD LONGITUDINAL WELD B-K F-A F-A F-A F-A F-A F-A B-K MRP-146 MRP-146 MRP-146 MRP-146 MRP-146 F-A R-A C-C F-A F-A R-A R-A R-A R-A R-A R-A R-A R-A R-A R-A R-A R-A C-C F-A C-A R-A R-A R-A B10.20 FI.10L Fl.10N FI.10R FI.1OR FI.10R FI.10R B10.10 DENG DENG DENG DENG DENG F1.20N R1.12 C3.20 F1.20R Fl.20R R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 C3.20 F1.20S C1.20 R1.11 R1.11 R1.11 PT VT-3 VT-3 VT-3 VT-3 VT-3 VT-3 MT UT UT UT UT UT VT-3 VT-2 PT VT-3 VT-3 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 PT VT-3 UT.

UT UT UT 0107A-4 0107A-4 0375C-5 0376A-1 0376A-1 0376A-1 0376A-1 E-001A-3 0357A-4 02228-5 0375E-5 0375F-5 0375C-5 0115A-6 01 92A-6 0193A-4 0194A-3 0194A-3 0265A-7 0265A-7 0265A-7 0265A-7 0265A-7 0265A-7 0267A-5 0267A-5 0267A-5 0268A-5 0272A-5 0273A-3 0223A-4 0223A-4 E-001N-4 0074C-3 0074C-3 0074C-3 Page AI-3

APPENDIX I 1 R22 COMPLETED CODE EXAMS SummaryNo 700100 703450 703500 707550 709250 711650 913870 914850 916250 929500 929600 929700 841200

.853750 853760 866200 870400 109083 930000 930310 N/A N/A N/A N/A N/A N/A N/A N/A Component ID RH-4-3A-F-5A RH-8-1-L-35 RH-8-1-S-1 1 RH-009 RH-004 RH-13-1-F-02 CH-120 CH-051 CH-050A CH-095 CH-096 CH-097 CC-1 14-R-15D-3 CC-202-1-A-03 TO 06 CC-202-A-15C-1 FC-4-HSS-5A WR-1 9-HSS-300 1 RN-073 1CNMT-LINER 1CNMT-EMERHATCH 1 R22-01Z 1 R22-02Z 1 R22-03Z 1 R22-04Z 1 R22-05Z 1 R22-06Z 1 R22-07Z 1 R22-08Z Description Class Category Item Method Iso Status PIPE WELD LONGITUDINAL WELD PIPE WELD RI-ISI SEGMENT RI-ISI SEGMENT PIPE WELD RI-ISI SEGMENT RI-ISI SEGMENT RI-ISI SEGMENT RI-ISI SEGMENT RI-ISI SEGMENT RI-ISI SEGMENT SUPPORT WELDED ATT SUPPORT A-15C(1)

SUPPORT SNUBBER SNUBBER RANDOM LINER 73 CONTAINMENT LINER EMERGENCY AIRLOCK BOLTING CONTAINMENT LINER 692' EL CONTAINMENT LINER 692' EL CONTAINMENT LINER 692' EL CONTAINMENT LINER 692' EL CONTAINMENT LINER 692' EL CONTAINMENT LINER 692' EL CONTAINMENT LINER 692' EL CONTAINMENT LINER 692' EL 2

2 2

2 2

2 2

2 2

2 2

2 3

3 3

3 3

MC MC MC MC MC MC MC MC MC MC MC R-A R-A R-A R-A R-A R-A R-A R-A R-A R-A R-A R-A F-A D-A F-A F-A F-A IWE E-A E-A N/A N/A N/A N/A N/A N/A N/A N/A R1.11 R1.11 R1.11 R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 F1.30R D1.20 F1.30A F1.30N FI.30N E4.12 E1.11 E1.11 N/A N/A N/A N/A N/A N/A N/A N/A UT UT UT VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-2 VT-3 VT-1 VT-3 VT-3 VT-3 UTT GV VT-1 UTT UTT UTT UTT UTT UTT UTT UTT 0074C-3 0074C-3 0074C-3 0075A-5 0075A-5 0075B-3 01 70B-3 1254A-4 1254A-4 1518A-1 1538A-1 1510A-1 01 79A-2 0286A-5 0286A-5 0071A-1 0067A-4 Plate W9 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Page AI-4

APPENDIX II REPAIR / REPLACEMENT ABSTRACT AND NIS-2 FORMS

NIS-2 ABSTRACT FORM NO.

3232 3233 3250 3251 3315 3327 3372 3373 3375 3403 3497 3498 3499 3509 3513 3515 3518 3519 3522 3523 3543 3544 3546 3547 3548 3549 3550 3551 3565 3566 3569 It 3571 3576 is 3578 3581 3583 3608 3609 3610 3611 FUNCTIONAL LOCATION.

1 CH-471 1CH-291 1RW-150 1RW-126 RV-1 RH-721 1RW-158 TCV-IRW-101B TCV-1RW-101A 1WR-P-1B 1RW-159 PCV-1MS-101A PCV-1 MS-1 01B PCV-1 MS-1 01C 1CH-84 REJ-1ARW-6B 1 RW-150 MOV-1QS-101B 1 RC-244 REJ-1ARW-19B REJ-1RW-1 8B 1 FW-622 1 FW-623 1RS-E-1A 1RS-E-1C WR-45 REJ-1 RW-1 9A REJ-1RW-18A REJ-1 RW-6A REJ-1 RW-25R 1MS-20

=1 RV-1 RC-551 B 1SI-P-1B RV-1 CH-203 of RV-1 CH-391 1 RW-1 06 MOV-IRW-102B2 SI-HSS-519 SHP-HSS-209 SHP-HSS-210 SHP-HSS-211 ORDER NO.

200285503 200388791 200383349 200383171 200434868 200420668 200396226 200396225 200244642 200440775 200407760 200407761 200407762 200500916 200498218 200501878 200514360 200511263 200498214 200518565 200447385 200447386 200507908 200507910 200533313 200498213 200498211 200498217 200507904 200505415 200508879 200479091 200504239 200247037 200434869 200504248 200504250 200508880 200502886 200513520 200513523 200513524 200513528 COMMENTS Installed Installed Corrected Corrected Corrected Installed Installed Installed Installed Installed Installed Installed Installed Installed Installed Corrected Corrected Installed Installed Installed Corrected Corrected Corrected Corrected Installed Installed Installed Installed Installed Installed

.1 Installed Corrected Installed Corrected Installed Installed Installed Installed Installed Installed Page 1 of 2

NIS-2 ABSTRACT FORM NO.

3612 3613 3614 3616 3617 3620 3621 3624 3625 3626 3627 3628 3629 3630 3631 3633 3634 3635 3636 3641 3642 3644 3645 3646 3651 3658 3659 3667 3668 3669 3670 3673 3676 3677 3678 3679 3681 3682 3691 FUNCTIONAL LOCATION SHP-HSS-212 SHP-HSS-214A RC-HSS-302 RC-HSS-3 RC-HSS-4 RH-HSS-124 RS-HSS-221 SI-PSSP-3 SI-PSSP-36A SI-PSSP-2 SI-HSS-516A SI-HSS-516B 1RW-144 1RW-137 1RW-142 MOV-1 RW-1 02A2 1 FW-36 MOV-IRW-103A 1 FW-T-2 MOV-1 RW-1 03B TV-1iMS-101C 1RW-145 1RW-151 1 RW-1 56 1CC-E-1B 1 FW-156A 1 MS-464 WR-20 SI-163 WAPD-3 WR-8 1 RCP-3F 1RH-E-1A PS-6 1 MS-1 9 LCV-1 CH-460A 1-RCBX 1 RH-2 VS-59A ORDER NO.

200513529 200513530 200513532 200513536 200513538 200513543 200513555 200513562 200513564 200513567 200513576 200513579 200503474 200504115 200504124 200418390 200432754 200436325 200440223 200502825 200507885 200502816 200502817 200504125 200562915 200406970 200486539 200546744 200564451 200564397 200564457 200501635 200508061 200501227 200579267 200376149 200578712 200578610 200581153 COMMENTS Installed Installed Installed Installed Installed Installed Installed Installed Installed Installed Installed Installed Corrected Corrected Corrected Installed Corrected Installed Corrected Installed Corrected Corrected Corrected Corrected Corrected Corrected Installed Installed Corrected Corrected Corrected Installed Corrected Installed Corrected Corrected Corrected Corrected

-Installed Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 00 Report Number 3232

1. Owner FirstEnerqy Nuclear Generation, LLC Date 07/22/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

Shippingport, PA 15077 WO# 200285503 (ADDRESS)

RepairlReplacement Organization P.O. No., Job No., etc.

3. Work Performed By BVPS - Maintenance Type Code Symbol Stamp N/A (NAME)

Shippinoport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System River Water (Q3)
5. (a) Applicable Construction.Code ANSI B31.1 1967 Edition, S'1971 Addenda, N/A Code Case (b) Applicable Edition of Section X] Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section X1 Code Case(s): N/A
6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Valve N/A N/A N/A 1 CH-471 1976 Removed No Valve Wyle Labs.

N/A N/A 1CH-471 2011 Installed No

7. Description of Work Replace valve.
8. Tests Conducted:

Hydrostatic* []

Pneumatic* LI Nominal Operating Pressure LI Exempt Z Other L]

Pressure psi Test Temp.

OF Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT.FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 00 Report Number 3232

9. Remarks No Code Data Report and No previous NIS-2 Reports. Valve PO# 45362720 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed J.Sciulli Nuclear Engineer III Date

ý"oll 270-,

20 % 3 Owner Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5-- /(-

/,;-

to

7-Z3

? - 1/3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

/.*

.J Commissions V, 2-' 7 4,,-'.-r72-3 *3 V Inspec/

s Signature National Board, State, Province, and Endorsements Date

?-,7 01

. 20 /3 I

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 00 Report Number 3233

1. Owner F.E.N.-e-e 6&-/I(2C~

I Date 10/29/2012 (NAME)..-y.Q* iP4t-p 76 South Main Street - Akron, OH 44308 (ADDRESS)

Sheet 1

of Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

ShippinqDort, PA 15077 Work Order # 200388791 (ADDRESS)

3. Work Performed By BVPS - Mechanical Mainteance (NAME)

Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A 4.

5.

6.

Shippinqport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A Identification of System Chemical and Volume Control System (Q3)

(a) Applicable Construction Code ANSI B31.1 1967 Edition, S'7A Addenda, -Code Case N/A (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E - 2003A (c) Applicable Section Xl Code Case(s):

Identification of Components Corrected, National

Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Valve N/A N/A N/A 1 CH-291 1976 Removed No Valve Wyle Labs.

N/A N/A 1CH-291 2011 Installed No

7. Description of Work Replace check valve
8. Tests Conducted:

Hydrostatic* El Pneumatic* LI Nominal Operating Pressure.

Exempt Other EL Pressure psi Test Temp.

F

-Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 00 Report Number 3233

9. Remarks No previous NIS-2 or Code Data Reports. Valve PO# 45362720 Applicable Manufackuer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed J.Sciulli 1,\\

Z,.

eJ,*

Date October29

, 20 12 Owner df Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period y- /-

/I to

/ 0 F /-

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___L

__1_

Commissions,)9~~-~i,~z'-

Inspecir's Signature National Board, State, Province, and Endorsements Date

,20

/ 2-Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi.

NOP-CC-5703-02 Rev. 01 Report Number 3250

1. Owner FirstEnerqy Nuclear Operatingq Company (NAME) 76 South Main Street - Akron, OH 44308 I Date 12/19/2013 (ADDRESS)

Sheet Unit No.

1 of 1

1

2. Plant Beaver Valley Power St*

(NAME)

P.O. Box 4. ShiDoinooort. PA 15077 ation (BVPS)

I I

(ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippingport, PA 15077 Order #200383349 RepairfRepfacement Organization P.O. No.. Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A 4.

5.

6.

(ADDRESS)

Expiration Date N/A Identification of System River Water (Q3)

(a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case -

(b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section XI Code Case(s): N/A Identification of Components Corrected, National

Removed, ASME Name of Name of Manufacturer Board Other Year.

or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Ball Valve Anchor/Darling EZ603-1-8 N/A 1 RW-1 50 -

1995 Corrected No End Piece Flowserve N/A N/A Trace 2011 Installed No

  1. 102360-2 End Piece Flowserve N/A N/A Trace 2011 Installed No
  1. 102361-1 3" Elbow Energy &

N/A N/A Ht. #LZSR-1 2003 Installed No Process 3" Tee Energy &

N/A N/A Ht. #NHZI-1 2013 Installed No Process

7. Description of Work Replaced valve end pieces and pipe elbow and tee.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* Ei Nominal Operating Pressure [

Exempt [

Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3250 Other E1 Pressure psi Test Temp.

__°_F

'Record test pressure and temperature

9. Remarks No Code Data Reports available. Previous NIS-2 Data Report No. 3515.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear EngineerV Date December 19, 20 13 Owner or Owner's esignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

.5-1 / - / d,-

to f/- (1-13

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions /1/9 Ncý Y,,

4 d-3 Y Inspect sSignature National Board, State, Province, and Endorsements Date

/--/0, 20/Y Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY

  • As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3251
1. Owner FirstEnergy Nuclear Operating Company Date 12/19/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippinaport, PA 15077 Order #200383171 (ADDRESS)

RepairlReplacement Organization P-0. No,. Job No., etc,

3. Work Performed By BVPS Construction Services Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippincport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI 831.1 1967 Edition, S'71 Addenda, Code Case -

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Ball Valve BNL Industries B021016-1-3 N/A 1RW-126 2003 Corrected No End Piece BNL Industries N/A N/A Trace 2010 Installed No

  1. D4731 End Piece BNL Industries N/A N/A Trace 2010 Installed No
  1. D4732 6" Pipe Energy &

N/A N/A Ht.

2006 Installed No Process

  1. 811818M01 6" Flange Energy &

N/A N/A Ht. #857B 2002 Installed No Process

7. Description of Work Replaced valve end pieces, pipe, and flange.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* El Nominal Operating Pressure 0 Exempt El Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1 NOP-CC-5703-02 Rev. 01 Report Number 3251 Other []

Pressure psi Test Temp.

oF Record test pressure and temperature

9. Remarks No Code Data Reports available. Previous NIS-2 Data Report No. 1833.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear EngineerV Date December 20, 20 13 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

,-5-//- /oL.

to i- -

-/3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

! 'j 4 JSignailJre Commissions 9J-9/-rJ-d4 If"6 A

3i 7Lvy Insp e

National Board, State, Province, and Endorsements Date

,20

/V Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3315

1. Owner FirstEnerav Nuclear ODeratina Companv I Date 12/06/2013 (NAME) 76 South Main Street - Akron. OH 44308 (ADDRESS)

Sheet Unit No.

1 of 1

2. Plant Beaver-Valley Power Station (NAME)

P.O. Box 4, Shippinqport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Maintenance (NAME)

P.O. Box 4, Shippinciport, PA 15077 (BVPS)

Order #200434868 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A (ADDRESS)

Authorization No.

Expiration Date N/A N/A

4. Identification of System Residual Heat Removal (Q2)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case--

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National Removed, -

ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Relief Valve Crosby N69973 N/A RV-1RH-721 1988 Corrected No 0001 Spring Crosby NX3172-0003 N/A N/A 1992 Installed No Washers Crosby N91725 N/A N/A 1992 Installed No 0308 & 0310

7. Description of Work Replaced relief valve spring with washer set.
8. Tests Conducted:

Hydrostatic* ]

Pneumatic* L]

Nominal Operating Pressure LI Exempt Z Other LI Pressure psi Test Temp.

° F tRecord test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3315

9. Remarks No Code Data Report available. Previous Nis-2 Data Report No. 3304.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White 4

-e

\\$Iýý Nuclear Engineer V Date December 20, 20 13 Owner or Owner's De gnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

_,;-- //-/

2 --

to

/(-

L/- / 3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions 1%l

?41oý 14,Jýi-AS

/

A??

Inspect s Signature National Board, State, Province, and Endorsements Date

.1-

, 20 /9i Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 00 Report Number 3327 A4.414A

1. Owner FirstEnercqy Nuclear Generation Corp.

I Date 01/02/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 2

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippinqport, PA 15077 Work Order #200420668 (ADDRESS)

RepairlReplacement Organization P.O. No.. Job No., etc.

3. Work Performed By BVPS Maintenance Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, ShippinQport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code Section III 19 77 Edition, S79 Addenda, Code Case --

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Duo-Check Crane Nuclear D4669 N/A 1RW-158 2006 Removed Yes Valve Duo-Check Crane Nuclear E0741 N/A 1RW-158 2011 Installed Yes Valve

7. Description of Work Replaced valve with spare.
8. Tests Conducted:

Hydrostatic* [

Pneumatic* LI Nominal Operating Pressure 0 Exempt El Other L1 Pressure psi Test Temp.

-F

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 00 Report Number 3327 A4.414A

9. Remarks NPV-1 Data Report for new valve attached. Previous NIS-2 Data Report No. 1933. ASME Section III Applicable Manufacturer's Data Reports to be attached Class 3 valve is installed into an ANSI R31 1 19R7E-S'71A desionnd.*vstem_

Class 3 valve is installed into an ANSI B31 1 1967E-S'71A desinned svstem CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp NIA Certificate of Authorization No.

N/A Expiration Date Signed T. White Staff Engineer D

Owner or Owner's Designee, Title N/A ate January 02, 2013 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

-- - / I to

/ -

1

- - /3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

J-)

Commissions d2 S

-9'k,

,ý).4 L2 Ycl Inspec(

Signature National Board, State, Province, and Endorsements Date

,20

/3 Page 2 of 2

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES-As Required by the Provisions of the ASME Code, Section 001, Division I Pg. 1 0 2

1.

Manufactured and certified by CRANE Nuclear, Inc., 860 Remington Boulevard, Bolingbrook, IL 60440 (name and address of NPT Certificate Holdej 7

2.

Manufactured for First Energy Corporation, PO Box 345 Shippingport; PA 15077 (name and address of purchaser)*

3.

Location of installation Beaver Valley Nuclear Power Plant, Route 168, Shippingport. PA 15077 (name and address)

4. Model NO., Series No., or Type K15-CEP Drawing CB02791 Rev.

8 CRN N/A 5.. ASME Code,Section III, Division 1:

1977 Summer 1979 3

(edition)

(addenda date)

(dass)

N/A (Code Case no.)

6.

Pump or valve Duo-Chek Valve Nominal inlet size 3

Outlet size "

. 3 (in.)

(in.)

7.

Material:

(a) valve Body SA351 CF8M (b) pump Casting NIA (a)

(b)

Cert.

Nat'l Holder's Board Serial No..

No.

Bonnet WA Cover NWA

.(c)

Body/Casing Serial No.

Disk

... SA351 CF8M Bolting N/A (d)

Bonnet/Cover Serial No.

Bolting SA479 TP 316 Disk Serial No.

E0741 N/A E0742 N/A E0743 & E0744 Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 8 'A x 11, (2) information in items 1 thiough 4 on this Data Report is induded on each sheet (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (E00037) may be obtained from the Order DepL ASME. 22 Law Drive, Box 2300, Fairfield. NJ 07007-2300.

FORM NPV-1 (Back) -

Pg. 2 of 2 E0741 Certificate Holder's Seral No.

89 9.

.Design conditions Cold working pre Psi

'F or valve pressure class 150 (1)

(pressure (temperature) ssure 275 Psi atl00F "F

425 Psi.

Disk differential test pressure 305 Psi SNo. 38670-01

10.

Hydrostatic test

11.

Remarks:

So Stop/Hinge Pin Retainers Heat Code: BSQ CERTIFICATION OF DESIGN Design Specifications certified by Francis Salmon P.E. State PA Reg. No.,

3385-E Design Report certified by N/A P.E. State N/A Reg. No.

N/A' CERTIFICATE OF COMPLIANCE We cerify that 'the statements made in this report are correct and that this pump or valve conforms to the rules for construction-of.the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-2899 Date 10/05/11 Name CRANE Nuclear, Inc.

(N Cetificate Holder)

Expires September 24. 2014' Signed' Jerome A. Kurowski. P.E.

Sr. Ouality Assurance Engineer CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSBCT of Hartford, CT Have inspected the pump, or valve, descrbed in this Data Report on 10/05/11 and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied. conceming the Component described in this Data Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date 10/05/11 Signed Commissions

(

edud tp.

Robert Rainey NISB 7742, IL 932 (Natl. 5 (and. endorsemenwts).ad state or pray. And mo.)

(1) For manually operated valves only.

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3372

1. Owner FirstEnercqy Nuclear Operating Companv (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)
2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippinqport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippinqport, PA 15077 Date 12/04/2013 Sheet 1

of 1

Unit.No.

Wr~rk Orde~r #290039Fi99R Repair/Replacement Organization P.O. No.. Job No.. etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date

4. Identification of System River Water (03)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case ---

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section XI Code Case(s): N/A

6. Identification of Components N/A Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Control Valve Masoneilan H-49378-133-2 N/A TCV-1RW-1976 Removed NO 101B Control Valve Masoneilan A-12-658340-N/A TCV-1 RW-2012 Installed No Dresser J001-2 101B 5/8" Studs Trust Manuf.

N/A N/A Ht. #783582 2011 Installed No 5/8" Nuts Nova Machine N/A N/A Trace #6W22 2012 Installed No 5/8" Nuts Nova Machine N/A N/A Trace #4P86 2010 Installed No 5/8" Nuts Nova Machine N/A N/A Trace #5R24 2011 Installed No

7. Description of Work Replaced valve, studs & nuts.
8. Tests Conducted:

Hydrostatic* D Pneumatic* D Nominal Operating Pressure Z Exempt D]

Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl r*OPF;-'CC-5703-02 Rev. 01 *..

- :FR,,ý ri'nb6T! 337-2-.

Other E]

Pressure psi Test Temp.

° F

'Record test pressure and temperature

9. Remarks No Code Data Report available.

pli.nble M!Ar air-t.

,Oc at*-R,.-pO, to be s*fhtný CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Sinned Thomas White Expiration Date N/A Nuclear Enqineer V Date December 05, 20 13 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period - //o4-to

//-

/- 1/3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_____________Commissions tn.

1 p ors Signature- - -

-National Board; State, Province, and-Endorsernents--

Date

/ C,1 -

1 20 /-?

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 00 Report Number 3373 A4.414A

1. Owner FirstEnergy Nuclear Generation e 4,/

Date 01/18/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippingport, PA 15077 Work Order #200396225 (ADDRESS)

Repair/Replacement Organization P.O. No.. Job No., etc.

3. Work Performed By BVPS Construction Services Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippingport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI B31.1 19 67 Edition, S'71 Addenda, Code Case -_

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A.

(c). Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME.

Name of Name of Manufacturer Board Other Year or Code Stamped Component.

Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Control Valve Masoneilan H-49378-133-1 N/A TCV-1 RW-1976 Removed No 101A Control Valve Masoneilan A-12-658340-N/A TCV-1.RW-2012 Installed No Dresser J001-1 101A 5/8" Studs Trust N/A N/A Ht. #783582 2011 Installed No Manufacturing 5/8" Nuts Nova Machine N/A N/A Ht.

2012 Installed No

  1. 5092414/6 W22 5/8" Nuts Nova Machine N/A N/A Ht.

2011 Installed No

  1. 5092414/6L 86
7. Description of Work Replaced valve, studs, and nuts with sp~are.

Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 00 Report Number 3373 A4.414A

8. Tests Conducted:

Hydrostatic* L]

Pneumatic* L]

Nominal Operating Pressure 0 Exempt I]

Other I Pressure psi Test Temp.

° F

  • Record lest pressure and temperature
9. Remarks No Code Data Report available.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed T. White Staff Enqineer Date January 22, 20 13 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the. undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5"-//-/4 to

/-

.JT.-

, and state that to the best of my knowledge andbelief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes-any warranty, expressed or implied, concerning the examinations and corrective measures.described in this Owner's Report. Furthermore, neither the. inspector nor

_ his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from.

or connected with this inspection.

A'2 Commissions IQ/12 AV Inspectors nature National Board, State, Province, and Endorsements Date *_

/__.__ ___-_-.

_,20

/3' Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 00 Report Number 3375

1. Owner FEN.GENCOý_ LLW I Date 05/09/2013 (NAME) -Akron.

vOH2-43.

0 76 South Main Street - Akron. OH 44308

2. Plant (ADDRESS)

Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4 Shiooinaoort. PA 15077 Sheet Unit No.

1 of 1

WO# 200244642 (ADDRESS)

3. Work Performed By BVPS-Mechanical Maintenance (NAME)

P.O. Box 4 Shippinqport, PA 15077 Repair/Replacement Organization P.O. No-, Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A 4.

5.

6.

(ADDRESS)

Expiration Date N/A Identification of System River Water (03)

(a) Applicable Construction Code ANSI B31.1 1967 Edition, S'1971 Addenda, N/A Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E -2003A (c)

Applicable Section XI Code Case(s): N/A Identification of Components Corrected, National

Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Pump Johnston 01JC1701S N/A 1WR-P-1B 1976 No Pump Pump Johnston 01JC17025 N/A 1WR-P-1B 2011 Installed No Pump Seal Box Johnston WY172 N/A 1WR-P-1B 2009 Installed No Pump Seal John Crane N/A N/A 1WR-P-1B 2012 Installed No Bolting Various*

N/A N/A Various*

Various Installed No

7. Description of Work Overhaul Pump.
  • See back of NIS-2 for the bolting information.
8. Tests Conducted:

Hydrostatic* El Pneumatic* El Nominal Operating Pressure [

Exempt []

Other D Pressure psi Test Temp.

°F Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 00 Report Number 3375

'Record test pressure and temperature

9. Remarks No previous NIS-2 data. No Code Data Reports Available. Studs and Nuts PO/HT# 10447 / 87071-RRT*,

45384940/6U100, 47318615/5V95, 45373868/M38601, 4725070/3M87, 45387487/M43619, 45373866/Mi9729, 45315454/3L76 and 45374031/6C48.

Applicable Manufacturer's Data Reports to be attached

  • CR 2013-07336 Written due to lack of QC Receipt Paperwork. Paperwork located on 05/28/2013.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed J.Sciulli Nuclear Engineer III Date June 4th

, 2013 Ownerhr Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 05-11-12 to 05-10-13

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

iý,-/

J S

Commissions r,4 10 W

6,?

SSignature National Board, State, Province, and Endorsements Date 6 -

, 20 0 Page 2 of 2

FORM NIS-2 OWNER'S. REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Requirbdby, the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 00 Report Number 3403

1. Owner F.E.N.*-.

AG-?Q.L L

Date 11/01/2012 (NAME) 1-76 South Main Street - Akron, OH 44308 Sheet 1

of 2

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

Shippingport, PA 15077 Word Order# 200440775 (ADDRESS)

Repair/Replacement Organization P.O-No., Job No., etc.

3. Work Performed By BVPS - Maintenance Type Code Symbol Stamp N/A (NAME)

Shippinqport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Chargqing Pump Cooler (Q3)
5. (a) Applicable Construction Code ASME III 19 77Edition, S'79 Addenda, N/ACode Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section XI Code Case(s):

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Valve Crane Nuclear D2080 N/A lRW-159 2003 Removed Yes Valve Crane Nuclear D4669 N/A IRW-159 2006 Installed Yes I

4 I

+/-

I

+

7. Description of Work Replace old check valve with a new check valve.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* El Nominal Operating Pressure ED Exempt EL Other LI Pressure psi.

Test Temp.

-_F

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 00 Report Number 3403

9. Remarks Previous NIS-2 Reports# 2005. Code Data Report Attached. Valve PO/SN: 45170559 D 04669 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed J.Sciulli Nuclear Enqineer Date November 1 20 12 Owner or-'eer's D~signee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

,,-//-7r to

/7 -/,k, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

jlt-.cr

-j 2

Commissions Pui f ybý T

/1 V

InspectoXSignature National Board, State, Province, and Endorsements Date

[(-

(0 20 Page 2 of 2

of 31)

FORM NPV,-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code,Section III, Division I Pg. 1 of 2

1.

Manufactured and certified by CRANE Nuclear, Inc., 860 Reminglon Boulevard, Bolingbrook, IL 60440 (name and address of NPT Certificate Holder)

2.

Manufactured for First Energy Corporation, PO Box 345 Shippingport, PA 15077 (name and address of purchaser)

3.

Location of installation Beaver Valley Nuclear Power Plant. Route 168. Shippingport. PA 15077 (name and address)

4.

Model No.. Series No., or Type K15-CEP Drawing CB02791 Rev.

B CRN N/A

5.

ASME Code, Section Ill, Division 1:

1977 Summer 1979 3

N/A (edition)

(addenda date)

(class)

(Code Case no.)

6.

Pump or valve Duo-Chek Valve Nominal inlet size 3

Outlet size 3

(in.)

(in.)

7.

Material:

(a) valve Body SA351 CF8M Bonnet WIA Disk SA351 CF8M Bolting SA479 TP 316 (b) pump Casting N/A Cover N/A Bolting N/A (a)

(b)

(c)

(d)

(e)

Cert.

Nat'l Body/Casing BonneViCover Disk Holder's Board Serial Serial Serial Serial No.

No.

No.

No.

No.

D4669 N/A D4670 N/A D4671 & D4672 Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is V / x 11. (2) information in items 1 through 4 on this Data Report is included on each sheet. (3) each sheet is numbered and the number of sheets is recorded at the top of this torm.

This torm 1E00D37) may be obtained from the Order Dept. ASME. 22 Law Drive. Box 2300. Fairfield. NJ 07007-2300.

,age 6 of 31).

91 FORM NPV-1 (Back) -

Pg. 2 of 2 Certificate Holder's Serial No.

D4669 8

Design conditions Psi "F or valve pressure class 150 (1)

(pressure (temperature)

9.

Cold working pressure 275 Psi at 1000 F

10.

Hydrostatic test 425 Psi.

Disk differential test pressure 305 Psi

11.

Remarks:

SO No. 27482-01 PO No. 45170559. Item 00001 Valve Tag: VCI-15X-Q CERTIFICATION OF DESIGN Design Specifications certified by Francis Salmon P.E. State PA Reg. No.

3385-E Design Report certified by N/A P.E. State N/A Reg. No.

N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

Date 05/25/06 Name N-2899 Expires September 24, 2008 Signed A

"(au*e6oeA representative)

Jerome A. Kurowski, P.E.

CRANE Nuclear. Inc.

(N Cerificate Haider)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and emplby HSBCT of Hartford. CT Have inspected the pump, or valve, described in this Data Report on 05125106 and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code, Section Ill, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the Component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date 05125106 Signed IL 1903 (efn.

Bd. find. endosenvents) and state or pray. And no.)

Commissions (1) For manually operated valves only.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1 NOP-CC-5703-02 Rev. 01 Report Number 3497

1. Owner FirstEnerav Nuclear Operatinl Company Date 01/08/2014 (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

Beaver Valley Power Station (BVPS)

Sheet 1

of Unit No.

1 2-Plant (NAME)

P.O. Box 4. ShioDinaport. PA 15077 Order #200407760 (ADDRESS).

3. Work Performed By BVPS Construction Services (NAME)

PCO) Box 4. Shinninonort PA 15077 Repair/Replacemeni Organization P.O. No., Job No., etc.

Type Code Symbol Stamp.

N/A Authorization No.

N/A Expiration Date N/A (ADDRESS)

4. Identification of System Main Steam (Q2)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case -

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section Xl Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Valve Copes-Vulcan 701095096-1-1 N/A PCV-1MS-1976 Removed No 101A Valve SPX Flow 10000028485 N/A PCV-1 MS-2013 Installed No Control 10 101A 1" Studs Trust Manuf.

N/A N/A Ht #M43140 2012 Installed No 1" Nuts Nova Machine N/A N/A Trace #6K14 2011 Installed No

7. Description of Work Replaced valve, studs & nuts.
8. Tests Conducted:

Hydrostatic* L]

Pneumatic* LI Nominal Operating Pressure Z Exempt L]

Other []

Pressure psi Test Temp.

° F

  • Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3497

9. Remarks No Code Data Reports available. Previous NIS-2 Data Report No. 1594.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date January 08, 20 14 Owner or Owner's

signee, CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or.Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

,5-- 1Y-w),Z to.

(( - V -

/3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

,2)dZ/,7r"f,*/?_-,1 d-1 Inspect s Signature National Board, State, Province, and Endorsements Date

, 20 Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Report Number 3498

1. Owner FirstEnergy Nuclear Operating Company (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)
2. Plant

- Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4. ShiDDinaDort. PA 15077 Date 01/08/2014 Sheet Unit No.

1 of 1

(ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippingport, PA 15077 (ADDRESS)

Order #200407761 Repair/Replacement Organization P.O. No.. Job No.. etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A

4. Identification of System Main Steam (02)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case --

(b) Applicable Edition of Section XA Utilized for. Repair/Replacement Activity 2001E-2003A (c)

Applicable Section XA Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year

-or.

Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Valve Copes-Vulcan 701095096-1-2 N/A PCV-1MS-1976

, Removed No 101B Valve SPX Flow 10000028485 N/A PCV-1 MS-2013 Installed No Control 11 101B 1" Studs Trust Manuf.

N/A N/A Ht #M43140 2012 Installed No 1" Nuts Nova Machine N/A N/A Trace #6K14 2011 Installed No

7. Description of Work Replaced valve, studs & nuts.
8. Tests Conducted:

Hydrostatic* FD Pneumatic* E]

Nominal Operating Pressure Z Exempt LI Other Ln Pressure psi Test Temp.

° F

'Record test pressure and lemperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3498

9. Remarks No Code Data Reports available. Previous NIS-2 Data Report No. 1566.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date January-,

20-14..

Owner or Owner's"-e5 gýn -ee-" T-"

it[

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

,5Y- / (- /,z to

/ -/

- / 3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this nspection.

,LQ/e* T

  • vKJ" Commissions d-,- 3'-/-,

F/

Inspector~ ignature National Board, State, Province, and Endorsements Date

/-/

, 20 Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3499

1. Owner FirstEnermv Nuclear Oieratinq Company IDate 12/13/2013 (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

Sheet Unit No.

1 of 1

2. Plant Beaver Valley Power St*

(NAME)

P.O. Box 4. Shiooinaoort. PA 15077 ation (BVPS)

Order #200407762 (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippinqport, PA 15077 Repair/Replacement Organization P.O. No.. Job No.. etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date

4. Identification of System Main Steam (02)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case ---

(b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components N/A Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Valve Copes-Vulcan 701095096-1-3 N/A PCV-1 MS-1976 Removed No 101C Valve SPX Flow 10000028485 N/A PCV-1 MS-2013 Installed No Control 12 101C 1" Studs Trust Manuf.

N/A N/A Ht #M43140 2012 Installed No 1" Nuts Nova Machine N/A N/A Trace #6K14 2011 Installed No

7. Description of Work Replaced valve, studs & nuts.
8. Tests Conducted:

Hydrostatic* ED Pneurnatic* E]

Nominal Operating Pressure [

Exempt U Other F]

Pressure psi Test Temp.

"F

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3499

9. Remarks No Code Data Reports available. Previous NIS-2 Data Report No. 1595.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp. N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date December 13, 20 13 Owner or Owner's Des)lnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period -

/ / -/,'-

to

/(

- 1/- 13

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, SectiOn XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Je-

  • J 22 Commissions,,

/',J.r,'

/

,.2 Inspe~o's Signature National Board, State, Province, and Endorsements Date

/,t- - I

,20./1-Page 2 of 2

FORMNIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3509

1. Owner FirstEnergy Nuclear Operating Company Date 12/18/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 2

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippinqport, PA 15077 Order #200500916 (ADDRESS)

RepairJReplacement Organizatibn P.O. No., Job No., etc.

3. Work Performed By BVPS Construction Services Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippingport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Chemical and Volume Control (Q2)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case -

(b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section X1 Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Check Valve Rockwell Intl.

N/A N/A 1CH-84 1976 Removed No Check Valve Edwards 30AFU N/A 1 CH-84 1993 Installed Yes Valve 2" Pipe Energy &

N/A N/A Ht. #40553 2009 Installed No Process Y2" Studs Trust Manuf.

N/A N/A Ht. #8898247 2012 Installed No 1/2" Nuts Nova Machine N/A N/A Trace #7V08 2012 Installed No

7. Description of Work Replaced valve and pipe nipple. Replaced studs & nuts in FE-1 CH-1 13 pipe flange.
8. Tests Conducted:

Hydrostatic* L]

Pneumatic* []

Nominal Operating Pressure [

Exempt []

Other L]

Pressure psi Test Temp.

F Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Report Number 3509

9. Remarks Code Data Report attached. Previous NIS-2 Data Report No. 3487. Valve was manufactured to ASME Applicable Manufacturer's Data Reports to be attached Section Ill, Class 1, 1971E-W'72A and is installed into an ANSI B31.1 system.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date December 18, 20 13 Owner or Owner' Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

.7-(1'-/o to

/( - V--/3', and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with is inspection.

Commissions Y

/V1f c 9-3 Inspe9 6r's Signature National Board, State, Province, and Endorsements Date

/c2 "/-

20 3

Page 2 of 2

POR NPV1 NCEJ1ACTE HODLDEA9,:DATA ýEOT O

UCERVLE As~Ri~jh by he ro9viSiifl o tihe-ASME Code,Section III, DIvA i Mnuf~cl~rt byV~AAJVZ y

.AJ2~

i A~fB

~

2'7603

". '.. "ANamei ddress of N.CertlficateHolder)

4.

Mructa~ed foi of n L :,4£ri~

~35 3 Loszi~a f lntafet~

l~arI Pj STA¶i~..J AK ln~OH 14194 976Q~

(Namn.er GOA~ddiesl 01 4, ýPuoip o VTalve"

/*

T Nomrinal Inilet Size Z

Outlet Size (inch) finch)

(alMo~l N

(bN Certificate Holder's (c) Canadaon oSeril nIf)

Nat Year

-TNNo.'..'

No.

tel Cla*$

No.

Built

~ ~7'FRi 2WflE)Fk

-/f x ~soft A

9 I

f3) w..

q1101 felige aescelpion Ofsr ic tpwi choiu-,K a aun OlnodIon s

2500 p

  • F oVolvoPressre Class-

.7., CW o rk t rpsi at 100rF.

"o....:.

Ma-erial Spec-No.

Manufac.ur.r.

-'-m.-h eti

_1 (gman_

11) For manually operated valves on.y.

Supplemental sheets in form of lists, sketche$ of drawvings may be used provided (1) site.

xsS/

11'.(121 irnformaitiori In items 1. 2 and 5 on ?hip Dalae Repor i s included on Qlach sheet. and 13) each sheet Is numbere clar~d~nujmbeir of -sheiks' is recorded afto !of this form.

  • i-*-i,:...~~~~~~.

.... :.i**-

1'101771 Thl '*ormI EDD0371 fav be obvlo'ned fr the Oad.r Mot.. ASME. 345 E. 47th St...

1 017 PG

-OF:.: "/

T.9 I.Iei)..............................

i..................*,-,i-......

T.h*:

tI

~i..

K o,

a J.~

I II tv~e~ifi'he atrf t 1

hilmade in 'this teport. as* correct snd, tat this th pw",.~

a~~~~talP@,S i*..:.n.i i,.,

.h

-,.:O-W..

f 7

cntrulo odeh oruclear. ower aun% Co rgonens.'

tect`ol AddndAA

-ode.C.s-Signc*

,n.. _,.-".:,'.ic..

Our ME 4n' l

'o

4.

.......7".

-o

u.
i........

ymboa.ae D e.jrs inf.r.acion

.i.

l. at

,-....1-.

Stye"s analysis repoct ICI&&% I 661v on file at F'

VI JI Design specificationt ceritifed by III~I" 6i~A PE Stt X~L neg. No. -3 425'&-.

SteshalyI C tili~d by I2 I I.

z b

~

4 7'1A PEg

Nta, L--.

N i I S-gnalure not 'evvaet. List name only.

cEr fRATE 0fSOF It'4OP4 CT I ine vundetsiqned. noiding a valid comtmissiont istsud 114 th

  • Ninal ioa'rd Of Boie and Prt55M" t*4420.1 InSpectOOp and thet State of Province of

'Anjd. e-id mp toed t" U~~ 4T of xhave insjtecte.d the um.

or.va I.in

7 IN

-: ' " "t.

R:iell On,:

19 5 and statethat to this best of myliiiadbeie he1 CnfasokehM on structea thiis purma, or valva. in accordance with the ASWE Code. Secti'on III.

8B' signing %hit cenificats. neither the Inspector nor his ernployar makes any waray epea or "noliad, conan" th~e cou~pment described in th~is Data Report. Jfunhermore, neither the Inivector sibr his emhployer $hall be rabl*'in anyr mranne# for any personal injury or prop"rt damage or a loss of any kinid arlsing'I fr11oii oVnectead Swfththis InspectO3

-ii~o'7KrINeI so. stask Pgov' and, W.).

G" --.

i.-!

i

'.,27;.: :*:::,:.:-:..,.. :.**:;5..:.*.:,:*:':..*:.*!:

.. :...,.... :..f...:.f

FORM NIS-2 OWNER'S REPORT FOR REPAGRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 00 Report Number 3513

1. Owner FirstEnerqy Nuclear Generation, LLC (NAME) 76 South Main Street - Akron, OH 44308 I Date 07/22/2013 (ADDRESS)

Beaver Valley Power Station (BVPS)

Sheet Unit No.

1 of 1

2. Plant (NAME)

Shippingport, PA 15077 (ADDRESS)

3. Work Performed By BVPS -Maintenance (NAME)

Shippincport, PA 15077 WO# 200498218 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A 4.

5.

6.

(ADDRESS)

Expiration Date N/A Identification of System River Water (03)

(a) Applicable Construction Code ANSI B31.1 1967 Edition, S'1971 Addenda, N/A Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A Identification of Components Corrected, National

Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Expansion Joint Garlock 0-2497 N/A REJ-1 RW-6B 2000 Removed No Expansion Joint Garlock 13-1516970-01 N/A REJ-1RW-6B 2013 Installed No Studs Trust Manuf.

N/A N/A HT#: 5S15 2012 Installed No Nuts Nova N/A N/A HT# 7N06 2012 Installed No Machine

7. Description of Work Replace REJ and bolting
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* El Nominal Operating Pressure [

Exempt LI Other LI Pressure psi Test Temp.

°_F lRecord test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

-NOP-CC-5703-02 Rev. 00 Report Number 3513

9. Remarks No Code Data Report. Previous NIS-2# 1325 and 1431. Expansion Joint PO# 45400397, Studs/Nuts PO/HT# 47401732/5S15 and 47417661/7N06 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type C*cre Symbol Stamp N/A.

Certificate of Authorization No.

N/A Expiration Date N/A Signed J.Sciulli Nuclear Engineer III Date July22

, 20 13 Owner 0/' wner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

-/

15

/ 1-to

- - -3

-/3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

.Commissions

,-J2.7e-1A7 i/i.Jw-S7 Z*J3 7,/

InspectorCSignature National Board, State, Province, and Endorsements Date 7-7 0

, 20

/2 Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 00 Report Number 3515 A4.414A LL-Q.

1. Owner FirstEnergy Nuclear Generation.o Date 01/21/2013 (NAME).

76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippinqport, PA 15077 Work Order #200501878 (ADDRESS)

RepairlReplacement Organization P.O. No., Job No., etc.

3. Work Performed By BVPS Maintenance Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippinqport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI B31.1 19 67 Edition, S'71 Addenda, Code Case ---

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section X1 Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Valve Anchor/Darling EZ603-1-8 N/A 1RW-150 1995 Corrected No Enclosure TEAM Inc.

91922 N/A N/A 2012 Installed No

7. Description of Work Installed leak repair enclosure with associated studs/nuts.
8. Tests Conducted:

Hydrostatic* -]

Pneumatic* L]

Nominal Operating Pressure [

Exempt E]

Other F]

Pressure psi Test Temp.

°_F

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNEWS REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 00 Report Number 3515 A4.414A

9. Remarks No Code Data Report available. Previous NIS-2 No. 905. The leak repair enclosure supplied under PO Applicable Manufacturer's Data Reports to be attached 4593991 consisted of Enclosure & Stronqback-Ht. #C3398: 5/8" Studs-Ht. #9DDO: Y" Studs-Ht. #7PN1: 3/8" Studs-Ht. #C3542: 5/8" Nuts-Ht. #3L861: '/" Nuts-Ht. #3N677: 3/8" Nuts-Ht. #3P160.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

Signed T. White N/A Expiration Date N/A Staff Engineer Date January 21, 20 13 Owner or Owner's Designee, Title CERTIFICATE-OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

.-7-//-

/,=2-to

/ 6 -,.---,K?, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspe,0 6r's Signature Commissions ^t12/ /:'

z7*-

'-V r

-& 1,-Z3 k V/

National Board, State, Province, and Endorsements Date

/6 - 0,,5- -

,20 /3 Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3518

1. Owner FirstEnerqy Nuclear Operatingq Company Date 12/04/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

UnitNQo 1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippingport, PA 15077 Work Order #200514360 (ADDRESS)

Repair/Replacement Organization P.O. No. Job No-, etc-

3. Work Performed By BVPS Maintenance Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippinqport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Quench Spray (02)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case--

(b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Gate Valve Pacific Valve 164052 N/A MOV-1 QS-1976 Corrected No 101B 5/8" Stud Nova Machine N/A N/A TC-3N12 2009 Installed No 5/8" Nut Nova Machine N/A N/A TC-4P86 2010 Installed No

7. Description of Work Replaced one stud and two nuts.
8. Tests Conducted:

Hydrostatic* L]

Pneumatic* E]

Nominal Operating Pressure LI Exempt E Other []

Pressure psi Test Temp.

OF

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 ReV. 01 Report Number-3518-.

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 278.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed ThomasWhite Nuclear EngineerV Date December 04, 20 13 Owner or Owner-s IYesignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period J-*-//- (A to

//

/3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with t is inspection.

2/Commissions r-J Y

Inspec~ s Signature National Board, State, Province, and Endorsements D.ate

_,-.-_/%

20

/-..

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3519

1. Owner FirstEnerqv Nuclear Operatinq Company I Date 01/08/2014 (NAME)

.6 Sbouth Main Street - Akron, OH 44308 Sheet Unit No.

(ADDRESS)

Beaver Valley Power Station (BVPS) 1 of 1

1

'1Iant (NAME)

P.O. Box 4. ShiDoinacort. PA 15077 (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4. ShiDDinooort. PA 15077 Order #200511263 Repair/Replacement Organization P.O. No.. Job No.. etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A (ADDRESS)

4. Identification of System Reactor Coolant (Q1)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case -

(b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Tubing Stone &

N/A N/A 1 RC-244.

1976 Removed No Webster Tubing FirstEnergy N/A N/A 1 RC-244 2013 Installed No

'/2' Tube Energy &

N/A N/A Ht. #41397 2012 Installed No Process

'" Union Energy &

N/A N/A Ht. Nos. YLD, 2013 Installed No Process YZZ, YDF, YPG

7. Description of Work Replaced section of tube and unions.
8. Tests Conducted:

Hydrostatic* El Pneumatic* []

Nominal Operating Pressure LI Exempt [

Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3519 Other F]

Pressure psi Test Temp.

° F Record tesl pressure and lernperature

9. Remarks No Code Data Reports available.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date January 08, 20 14 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

,57-- /(

(,-,

to (t( - V'/-3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any" kind arising from or connected with this inspection.

_Commissions pJo4 Vp rlYv~r A

l X

InspectorýýSgnature National Board, State, Province, and Endorsements Date

/-10

, 20 Page 2 of 2

FORM NOS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Ndmber 3522

1. Owner FirstEnergy Nuclear Operating Company (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

I Date 12/04/2013 Sheet 1

of UnitNo.

1

2. Plant Beaver Valley Power Station (BVPS) 3.

(NAME)

P.O. Box 4, Shippingport, PA 15077 (ADDRESS)

Work Performed By BVPS Maintenance (NAME)

P.O. Box 4, Shippingport, PA 15077 (ADDRESS)

Work Order #200498214 Repair/Replacement Organization P.O-No., Job No.. etc.

Type Code Symbol Stamp Authorization No.

Expiration Date N/A N/A N/A

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case --

(b)

Applicable Edition of Section Xi Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Expansion Garlock N/A N/A REJ-1RW-19B 2000 Removed No Joint Expansion AP Services 13-1437937-01 N/A REJ-1RW-19B 2013 Installed No Joint LLC

7. Description of Work Replaced expansion ioint.
8. Tests Conducted:

Hydrostatic* D]

Pneumatic* E]

Nominal Operating Pressure Z Exempt LI Other F]

Pressure psi Test Temp.

_F

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703.-02 Rev. 01 Report.Number..3522

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 1240.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White

_i Nuclear Engineer V Date December 04, 20 13 Owner or Owner's bresignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period -/(1-

/,,:;-

to

// /..

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

,d ',Y9'- g

,,# z-L-

Inspect Signature National Board, State, Province, and Endorsements Date R -- V 201/-3.

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 00 Report Number 3523

1. Owner FirstEnergy Nuclear Generation, LLC Date 06/25/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet I

of 1

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4 Shippingport, PA 15077 WO# 200518565 (ADDRESS)

RepairlReplacement Organization P.O. No., Job No., etc.

3. Work Performed By BVPS - Mechanical Maintenance Type Code Symbol Stamp N/A (NAME)

P.O. Box 4 Shippingport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI B31.1 19 67 Edition, S'71 Addenda, N/A Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section Xi Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Expansion Joint.

Garlock 5-4007 N/A REJ-1RW-18B 1995 Removed No Expansion Joint Garlock 13-1437108-01 N/A REJ-1RW-18B 2013 Installed No

7. Description of Work Replace expansion ioint
8. Tests Conducted:

Hydrostatic* L]

Pneumatic* L]

Nominal Operating Pressure Z Exempt E]

Other MI Pressure psi Test Temp.

oF

  • Record lest pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 00 Report Number 3523

9. Remarks Previous NIS-2# 623, No Code Data Report. Expansion Joint PO# 45412933 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed J.Sciulli Nuclear Engineer III Date June 25, 20 13 Owner or,6wner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period S--/

(,-L to

'7 - a-.-

3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

/(

4 v"

~ecor'*inatreCommissions

-9 4'W d

  • ,/

lnspectorýAignature National Board, State, Province, and Endorsements Date 72 Q

, 20 Page 2 of 2

NOP-CC-570 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 3-02 Rev. 01 Report Number 3543

1. Owner FirstEnercqy Nuclear Operatingq Company i Date 10/30/2013 (NAME) 76 South Main Street-Akron, OH 44308 (ADDRESS)

Sheet Unit No.

1 of 1

2. Plant Beaver Valley Power Sta (NAME)

P.O. Box 4, Shippingport, PA 15077 (ADDRESS)

3. Work Performed By BV Valve Team (NAME)

P.O. Box 4, Shippinaport. PA 15077 tion (BVPS)

Work Order #200447385 Repair/Replacement Organization P.O. No.. Job No., etc.

Type Code Symbol Stamp N/A (ADDRESS)

Authorization No.

Expiration Date N/A N/A

4. Identification of System Auxiliary Feedwater (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case--

(b)

Applicable Edition of Section X1 Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section X1 Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Check Valve Rockwell Intl.

N/A 1FW-622 1976 Corrected No Disc Flowserve N/A N/A Ht. #257360 2013 Installed No

7. Description of Work Replaced valve disc and re-seal welded body to bonnet.
8. Tests Conducted:

Hydrostatic* []

Pneumatic* []

Nominal Operating Pressure M Exempt D Other []

Pressure psi Test Temp.

° F

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3543.

9. Remarks No Code Data Report available.

Applicable Manufacturers Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate Signed of Authorization No.

N/A Thomas White Expiration Date N/A Nuclear Engineer V Date October 30, 20 13 Thomas White

  1. I i

Owner or Owner's Iesignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

.-- 1/- 7'"

to

,/0

/ -,"2, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

I J 21 2 J2 Commissions~

/9~2'iIA4'io1 C

Inspe 7?s Signature F

National Board, State, Province, and Endorsements Date

. / 6 -- ? f-

,20 12.

Page 2 of 2

FORM HIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3544

1. Owner FirstEnerciy Nuclear Operatingq Company (NAME)

I Date 10/30/2013 76 South Main Street - Akron. OH 44308 (ADDRESS)

Sheet Unit No.

1 of 1

2. Plant Beaver Valley Power Sta (NAME)

P.O. Box 4, Shippincqport, PA 15077 (ADDRESS)

3. Work Performed By BV Valve Team (NAME)

P.O. Box 4, Shippinwport, PA 15077 tion (BVPS)

Work Order #200447386 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A (ADDRESS)

Authorization No.

Expiration Date N/A N/A

4. Identification of System Auxiliary Feedwater (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case ---

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section Xl Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Check Valve Rockwell Intl.

N/A 1FW-623 1976 Corrected No Disc Flowserve N/A N/A Ht. #257360 2013 Installed No

7. Description of Work Replaced valve disc and re-seal welded body to bonnet.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* E]

Nominal Operating Pressure [

Exempt [L Other M]

Pressure psi Test Temp.

_F

-Record lest pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3544

9. Remarks No Code Data Report available.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Sioned Thomas White Expiration Date N/A Nuclear EngineerV Date October30, 20 13 Owner or Owner'sDesige,,'Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period j-/

-Z,*

to

/ 0 -,.? / -/3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with t is inspection.

flo mihnn is~- inspection.3 Cv

  • V C o iss.

Inspectly Signature National Board, State, Province, and Endorsements

-Date... /0._,,

, 20_ -/-

Page 2 of 2

FORM NMS-2 OWNER'S REPORT FOR REPAURS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3546

1. Owner FirstEnerqy Nuclear Operating Company Date 12/02/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

.nit.N o.

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippinqport, PA 15077 Work Order #200507908 (ADDRESS)

RepairlReplacement Organization P.O. No., Job No.. etc.

3. Work Performed By BVPS Construction Services Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippingport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Recirculation Spray (Class C)
5. (a) Applicable Construction Code ASME Section III 1968 Edition, W'68 Addenda, Code Case --

(b)

Applicable Edition of Section Xi Utilized for Repair/Replacement Activity 2001 E-2003A (c)

ApplicableSection Xl Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name. of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Heat Industrial 6301-1 3179 1RS-E-1A 1971 Corrected Yes Exchanger Process Eng.

7. Description of Work Replaced seal welded diap.hragms.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* []

Nominal Operating Pressure LM Exempt [

Other F]

Pressure psi Test Temp.

°OF Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Rer-er-3546

9. Remarks Copy of original Data Report in NIS-2 #1577. Previous NIS-2 Data Report No. 3378.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date December 11, 20 13 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5-- /(--/4,2 to

/-'-

I-

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Q,

Commissions,VS ? d f;-

Inspec~'rs Signature National Board, State, Province, and Endorsements Date

/.,2-/d--

,20

(,.

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME.Code Section. XI NOP-CC-5703-02 Rev. 01 ReDort Number 3547

1. Owner FirstEnergy Nuclear Operating Company (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

Date 12/11/2013 Sheet 1

of 1

Unit N

2. Plant Beaver ValleV Power Station (BVPS)

(NAME)

P.O. Box 4, Shippingport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippingport, PA 15077 (ADDRESS)

Work Order #200507910 Repair/Replacement Organization P.O. No., Job No., etc Type Code Symbol Stamp Authorization No.

Expiration Date N/A N/A N/A

4. Identification of System Recirculation Spray (Class C)
5. (a) Applicable Construction Code ASME Section III 1968 Edition, W'68 Addenda, Code Case --

(b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Heat Industrial 6301-3 3181 1RS-E-1C 1971 Corrected Yes Exchanger Process Eng.

7. Description of Work Replaced seal welded diaphragms.
8. Tests Conducted:

Hydrostatic* []

Pneumatic* D Nominal Operating Pressure EI Exempt M Other []

Pressure psi Test Temp.

° F

'R

___ ____l Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions.of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Rport Nrr

-*-i

9. Remarks Copy of original Data Report in NIS-2 #1577. Previous NIS-2 Data Report No. 3378.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certifythat the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A

-Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date December 02, 20 13 Owner or Owner's D signee,_ Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

.5*-

//-

/,Z to

// 12

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for an-p-ersbni*irijury or property damage or a loss of any kind arising from or connected with this inspection.

/S -- 'intCommissions f11

,Id 4-/2z:7 lnspec6r's Signature National Board, State, Province, and Endorsements Date

/,L/,,L

, 20 13 Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAiRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1 NOP-CC-5703-02 Rev. 01 Report Number 3548

1. Owner FirstEnergy Nuclear Operating Company Date 12/13/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet.

1 of 1

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippingport, PA 15077 Order #200533313 (ADDRESS)

Repair/Replacement Organization P.O-No., Job No.. etc.

3. Work Performed By BVPS Construction Services Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippingport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System River Water (03)
5. (a) Applicable Construction Code ANSI 931.1 1967 Edition, S'71 Addenda, Code Case ---

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001E-2003A (c)

Applicable Section Xi Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Piping Duquesne N/A N/A WR-45 1996 Removed No Light Pipe Energy &

N/A N/A Ht. #525111 2010 Installed No Process Flange Tioga Pipe N/A N/A Ht. #246352 2010 Installed No 5/8" Stud Nova Machine N/A N/A Trace #8M79 2013 Installed No 5/8" Nut Nova Machine N/A N/A Trace #8H84 2013 Installed No

7. Description of Work Replaced section of pipe, flanges, studs & nuts.
8. Tests Conducted:

Hydrostatic* D Pneumatic* E Nominal Operating Pressure [

Exempt [

Other L Pressure psi Test Temp.

o F Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3548

9. Remarks No Code Data Reports available. Previous NIS-2 Data Report No. 905.

Applicable Manutacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date December 13, 20 13 Owner or tOwner's besignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

_-___-/_.__

to

//-

c/-/ 3.

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

,2.v p A '.*,d2 3

.C/

Insp 3r's Signature National Board, State, Province, and Endorsements Date

?-

, 20 Page 2 of 2

FORM M*,U2 MASHER'S REPORT FOR REPAIRS/REPLACEMENT ACTWVGTY As Required by the Provisions of the ASME Code Section Xf NOP-CC-5703-02 Rev. 00 Report Number

  • 4.-

,IV

1. Owner FEN.GENGL.4e Date 05/08/2013 (NAME)-$CW." -jZ'i 3 76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

Shippinqport, PA 15077 WO#200498213 (ADDRESS)

Repair/Replacement Organization P.O. No., Job No., etc.

3. Work Performed By BVPS - Mechanical Maintenance Type Code Symbol Stamp N/A (NAME)

O.f.*o-' *Shippinciport, PA 15077 Authorization No.

N/A I*

(ADDRESS)

Expiration Date N/A

4. Identification of System River Water System (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'1972 Addenda, N/A Code Case (b)

Applicable Edition of.Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Exp. Joint N/A N/A N/A REJ-1RW-19A 1972 Removed No Exp. Joint Garlock 13-1437938-01 N/A REJ-1RW-19A 2013 Installed No

7. Description of Work Replace expansion ioint
8. Tests Conducted:

Hydrostatic* L]

Pneumatic* LI Nominal Operating Pressure [

Exempt [l Other nI Pressure psi Test Temp.

° F

  • Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 00 Report Number 3349

9. Remarks No Previous NIS-2 Data.-Expansion Joint PO# 45412998 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authoriz n No.

N/A Expiration Date Signed J.Sciulli Nuclear Enqineer III Dz Owne or Owner's Designee, Title N/A ate May 8

,2013 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period S--//

/42) to

-- /2

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ )Commissions

/,&ý VY 7,49 A5.

pt y lnspectorI>ýignature National Board, State, Province, and Endorsements Date.

jF-2

, 20 /,?

Page 2of 2

FORMK 01S-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 00 Report Number 3550

1. Owner FEN.GEN.44.,QLC1+/-

I Date 05/08/2013 (NAME) " A OH 4430 76 South Main Street -Akron. OH 44308

2. Plant (ADDRESS)

Beaver Valley Power Station (BVPS)

Sheet Unit No.

1 of 1

(NAME)

Shiroinaoort. PA 15077 WO# 200498211 (ADDRESS)

3. Work Performed By BVPS - Mechanical Maintenance (NAME)

Shippinqport, PA 15077 Repair/Replacement Organization P.O. No., Job No.. etc.

Type Code Symbol Stamp N/A Authorization No.

N/A 4.

5.

6.

(ADDRESS)

Expiration Date N/A Identification of System River Water System (Q3)

(a) Applicable Construction Code ANSI B31.1 1967 Edition, S'1972 Addenda, N/A Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001E-2003A (c)

Applicable Section XI Code Case(s): N/A Identification of Components Corrected, National

Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Exp. Joint N/A N/A N/A REJ-1RW-18A 1972 Removed No Exp. Joint Garlock 13-1438819-01 N/A REJ-1RW-18A 2013 Installed No

7. Description of Work Replace expansion ioint
8. Tests Conducted:

Hydrostatic* EL Pneumatic*.I Nominal Operating Pressure Exempt El Other F]

Pressure psi Test Temp.

o F

  • Record test pressure and temperature Page 1-of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 00 Report Number 3550

9. Remarks No Previous NIS-2 Data. Expansion Joint PO# 45414010 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed J.Sciulli Nuclear Enqineer III Date May 8 20 13 Ownepkr Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period A5

-//-

/2_

to J--

?- -

-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

____Commissions AU/f

-/J7~

-3 P 74Zj lnspecto/,,, Signature National Board, State, Province, and Endorsements Date

__-_,20 12 Page 2 of 2

FORM NMS=2 OWNER'S REPORT FOR REPAORSIREPLACEMENT ACTWTY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 00 Report Number 3551

1. Owner FEN GENGý144 Date 05/08/2013 (NAME) 12JI-i 76 South Main Street - Akron, OH 44308
2. Plant (ADDRESS)

Beaver Valley Power Station (BVPS)

(NAME)

Shippinqport, PA 15077 Sheet 1

of 1

Unit No.

1 (ADDRESS)

3. Work Performed By BVPS - Mechanical Maintenance (NAME) e,0,-6-4*

ShiDDina Dort, PA 15077 WO#200498217 RepaidReplacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A 4.

5.

6.

(ADDRESS)

I Expiration Date N/A Identification of System River Water System (Q3)

(a) Applicable Construction Code ANSI B31.1 1967 Edition, S'1972 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A Identification of Components Corrected, National

Removed, ASIVIE Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Exp. Joint N/A N/A N/A REJ-1 RW-6A 1972 Removed No Exp. Joint Garlock 13-1437938-01 N/A REJ-1RW-6A 2013 Installed No Studs Various*

N/A N/A Various*

Various Installed No Nuts Various*

N/A N/A Various*

Various Installed No

7. Description of Work Replace expansion joint and boltincq
  • Studs/Nuts PO/HT Numbers listed on back.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* L]

Nominal Operating Pressure [

Exempt Li Other Li Pressure psi Test Temp.

'IF

-Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 00 Report Number 3551

9. Remarks No Previous NIS-2 Data. Expansion Joint PO# 45412998, Studs ands Nuts PO/HT#'s: 474017321SS15, 45392186/RR08. 47281776/4T10. 47403956/7X12 and 45347392/4S99.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed J.Sciulli Nuclear Enqineer III Date May8

, 20 13 Owner /Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors.

and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

-//-

/ *L to

.-- / V - (3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

J

--L-1 r l Commissions Jl_ý ",6, -

zV_ý,J

/0 d--?

c-/

lnspectorA Signature National Board, State, Province, and Endorsements Date

,20

/--2 Page 2 of 2

FORM NiS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01

.Report Number 3565

1. Owner FirstEnercqy Nuclear Operating Company Date 12/04/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippingport, PA 15077 Work Order #200507904 (ADDRESS)

Repair/Replacement Organization P.O. No., Job No., etc.

3. Work Performed By BVPS Construction Services Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippingport. PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case ---

(b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section Xl Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Expansion Garlock S/C 1001158 N/A REJ-1RW-25R 2000 Removed No Joint Expansion AP Services 13-1539481-01 N/A REJ-1RW-25R 2013 Installed No Joint LLC

+

+

+

7. Description of Work Replaced expansion ioint.
8. Tests Conducted:

Hydrostatic* D Pneumatic* D Nominal Operating Pressure 10 Exempt E]

Other F]

Pressure psi Test Temp.

-_F

  • Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 ReportNumber 3565

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 1272.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1..

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date December 04, 20 13 Owner or Owner's Deignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period -// /

to

/( /'?

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions IJY-77 4-/2:7d

,1)4 2-~

~/

Inspe s Signature National Board, State, Province, and Endorsements Dal-te.

2_0

.i_

Page 2 of 2

FORM NDS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02Rev. 01......".'"

Report Number 3566

1. Owner FirstEnerqy Nuclear Operatinq Company Date 12/04/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 2

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippinqport, PA 15077 Work Order Nos. 200505415, 200508879 (ADDRESS)

RepairlReplacement Organization P.O. No., Job No., etc.

3. Work Performed By BVPS Valve Team Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippinqport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Main Steam (Q2)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case ---

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Nozzle Enertech 10550 N/A 1MS-20 1997 Removed No Check Valve Nozzle Enertech 12247 N/A 1MS-20 2013 Installed Yes Check Valve

7. Description of Work Replaced valve with spare
8. Tests Conducted:

Hydrostatic* F

. Pneumatic* E]

Nominal Operating Pressure Ej Exempt E]

Other F]

Pressure psi Test Temp.

oF

-Record lest pressure and temperalure Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVfTY'-*

As Required by the Provisfons of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3566

9. Remarks Code Data Report attached. Previous NIS-2 Data Report No. 1710. Valve was supplied as ASME Applicable Manufactureres Data Reports to be attached Section III, Class 3, 1971E-S'72A but are installed in a B31.1 system.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization N(

Signed Thomas White N/A Expiration Date N/A Nuclear EngineerV Date December 04, 20 13 Owner or Owner's D"-signee, -Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period --// -/-

to

/( - L/- /3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions 'J'

/p-

,9 z,

/"q-~ 'g ?

Inspeelr's Signature National Board, State, Province, and Endorsements Date

,20_

/3 Page 2 of 2

FORM NPV-1 CGRTI,,CATE HOLDER'S DATA PEPORT FOR NUCLEAR PUMPS OR VALVES 0 As Required by the Provisions of the ASME Code,Section III, Division 1 Pg. 1 of 29-_

1. Manufactured and cerified by Enertech - A Business Unit of Curtiss-Wright Flow Control Co.; 2950 Birch St.; Brea, CA 92821 Ir..s snd Gdd, ot N C,*or ti.we HoW ),
2. Manufactured for First Energy Corp.; P.O. Box 6100; Johnstown, PA 15907-6100 fnme end -.,ddafs of ut"he*
3. Location of installation Beaver Valley Power Station; Route 168; Shippingport, PA 15077
4. Model No., Series No,, or Type DRV-Z Drawing PD98401 Rev.

N CRN N/A

5. ASME Code,Section III, Division 1 1971 Summer 1972 3

1672 & N-62-7 Nozzle Check (Addodsm it b

ai ppl tabi Icteost (Cod. Cate no.)

6. Pump or valve Valve Nominal inlet s;ze 3Y Outlet size 3"
7. Material SA105 GR II SA564 TP630 (a) valve Sody Norm.

Bonnet N/A Disk H1100 Bolting NIA (b) pump Casing Cover Bolting

. (a)

Cerlificate Holder's Serial No.

12247 (b)

National Board No.

N/A (c)

Body/Casing Serial No.

52388 (d)

(e)

Bonnet/Cover DIsk Serial Serial No.

No.

N/A 52923

  • Supplemental Infoirmaotion In the form of lists, s3Wethea, or drawings may be used provided: (I) size Is B't1 X 11; (2) Information In Items I through 4 on Ihis Data Repor Is Included on each sheet; and (3) each sheet Is numbered and the number of shGels is recorded at Ihoe top of this form.

(07110)

FORM NPV-1 TackC-P*2of 2_ )

Certificate Holder',s Seuiel No.

12247 B. DeslU conditions 1100PSIG.

560F"

". orvalve pr6ssureclaess

.. 600

8.

Design condition,

9. Cold working pressure. 1440PSIG @ 1000 F
10. Hydrostatic test 2175 PSIG

. Disk differential test prasiur-

1. Remarks Qty. 1, Enedtech Project Number: 390156:.,...

CElTIFICATION OF DESIGN.

Design Specification cedified by Francis W. Gardner RE. Stato PA Reg. no.

036614-E Design Report certified by Ira J. SIIvrman P.E. State Reg. no.

232.41 CERTIFICATE OF COMPUANCE We certify that the stat.ements made In this report are correct and that Ibis pump or valve conforms to the rules for constructign of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-2826 Expires October 11, 2014 Enertech, A Business Unit of___________________

Date O4.*Name Cuutiss-Wrlght Flow Control Corp.

Signed IN C*eItcst. I'oidr I olad r-p( amwnti -wl CERTIFICATE OF INSPECTION I, the d d

Ignped, holding a valid commission iss'dd by the National.oard'of Boiler to..

re Vessel In'spectois and ifii State or Province" of datirorna nad employed by "

I l

h.ve Iniphcted the purhp, or valve, d~scdbed In this Data Report on

- ['4 1

", and state that to the best of my ktnowledgb ind belief, the Certiflcatb Holder has const'ucted this pum rp, or valve, In accordance with the'ASME Code,Section III, Division 1.

By signing this.certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the component described in this Data-Report. Furthermore, neither-the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected w' Is inspection.

Datai/

4](

SignedZ.

Comsin

/N I4 zL gC

  • j (Aa, oiod=I Ntdeu toonsecte INafltr&l

.(Id.

tin ciso.nv). aend ots* ot proy. end no.)

(09/06) ioc/o C

z9 o,2-

FORM fNGIS-2 OWNER'S REPORT FOR REPADRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME.Code Section X.

NOP-CC-5703-02 Rev. 01 Report Number 3569

1. Owner FirstEnerqy Nuclear Operating Company (NAME) 76 South Main Street - Akron, OH 44308 IDate 12/04/2013 Sheet Unit No.

(ADDRESS)

Beaver Valley Power Station (BVPS) 1 of 5

_____!_.1

2. Plant P.O. Box 4, (NAME)

Shippinqport, PA 15077 Work Order Nos. 200479091, 200504239 (ADDRESS)

3. Work Performed By BVPS Maintenance (NAME)

P.O. Box 4. ShiDDinaport, PA 15077 Repair/Replacement Organization P.O. No-, Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A (ADDRESS)

4. Identification of System Reactor Coolant (Class A)
5. (a) Applicable Construction Code ASME Section III 1968 Edition, S'68 Addenda, Code Case--

(b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Relief Valve Target Rock 5

N/A RV-1 RC-2007 Removed Yes 551B Relief Valve Target Rock 3

N/A RV-1 RC-2005 installed Yes 551B Pilot Valve Target Rock 6

N/A N/A 2007 Installed Yes 1-3/8" Stud Trust Manuf.

N/A N/A Trace #PP18 2012 Installed No 1-3/8" Stud Trust Manuf.

N/A

  • N/A Trace #JJ21 2010 Installed No 1-3/8" Nut Nova Machine N/A N/A Trace #6X20 2012 Installed No 1-3/8" Hydra Nova Machine N/A N/A Lot 2013 Installed No Nut
  1. 45418343
7. D sc-ipiiori of Woirk Repiaced valve, piiot v di-Ve, d*-iu sus & tlLiS.

Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Report Number 3569

8. Tests Conducted:

Hydrostatic* E]

Pneumatic* El Nominal Operating Pressure [

Exempt []

Other El Pressure psi Test Temp.

O F

  • .
    dt4t me.=.ta.e :n,; ;e,"r*[-*r#_.rc
  • .-.=
9. Remarks Code Data Reports attached. Previous NIS-2 Data Report No. 3114. The pilot valve was replaced Applicable Manufacturer's Data Reports to be attached on serial number 3 relief valve by NWS under PO #55115381.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Cal Nuclear EngineerV Date December 06, 20 13 Owner or Owner's *esignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

,5--//- /,

to

/1-

-//3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

J 2

_C...

.commjissions,J KXT fb.z-...2-lnsp 6or's Signature National Board, State, Province, and Endorsements Date

/0Z- /9. -

,20

/2 Page 2 of 2

FORM* NV-1 CERTlFlCATE HOLDLERS' DATA REPORT FOR PRESSURE OR VACUUM RELIEF VALVES" As Rzq*PAý,ed by t Provi-'slons o9 ihe ASMiE M I, D!itision

1. Manufactured and certified by Target Rock; 1966E Broadhollow Rd.: E. Farmringdale. NY 11735 (name and address of NV Certificate Holder)
2.

Manufactured for First Enerav: Route 168: ShiDoinaoort.PA (name and address of Purchaser)

.. 1,-,ttCaon 'f insiailatioi, Boaera Vailey Pov;er Siation; Route i68;Sitcpincwort. PA (name and address)

4.

Valve 0569C-001-1 (Model no., series no.)

Orifice size 2.443 Nom. Inlet size 6

(in.)

(in.)

Outlet size 6

(in.)

5.

ASME Code, Section I11, Division 1:

1968 (edition)

Summer 1968 (addenda date)

A None (class)

(Code Case no.)

6. Type Pilot Operated 2485 120 650°F 3325 at_

0-itOF max.

(spring, pilot or power operated) (set pressure, psig) (blowdown, psi)

(rated temp)

(hydro test, psiginlet)

7.

Identification 3

(Cert. Holder's serial no.)

8.

Control ring settings -

N/A 0569C-001 Rev. B N/A 2005 (CRN)

(drawing no.)

(Natl'l. Bd. no.)

(year built)

N/A

9.

Pressure retaining items:

Serial No. Or Identification Mat'l. Spec.

Including Type or Grade Tensile Strength Body Bonnet or Yoke Support Rods Nozzle Disk Spring Washers Adjusting Screws Spindle Spring Bolting Other Items 3

SA351 CF8M!

75 ksi 9

SA105 70 ksi 2

SA 564 630 140 ksi See page 2 of 3 See paae 2 of 3

10. Relieving capacity 345,000 lbs/hr overpressure as certified by the National Board (69C) 10/07/2005 (date)
11. Remarks:

CERTIFICATION OF DESIGN Design Specification certified by F.W. Gardner P.E. State PA Reg. No. 036614-E Design Report certified by Not applicable P.E. State N/A Reg. No.

N/A CERTIFICATE OF COl,.PLIANCE We certiby that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code, Section !11, Division 1.

N Certificate of Authorization No.

Date 17-!.0 /2-0"o5 Name N-1949 Target Rock (Certificate Holder)

Expires 12/12/2007 Signe

-'q, R. E. Glazier,QA Manager (authorized representative)

ý upplemental information in form of lists, sketches, or drawings may be used provided (1) size is 8Y2 x 11, (2) information in items 1 through 4 on this Data Report is included on each sheet, (3) each sheet is numbered and the numher of sheets ;v recorded at the tar 'f thiQ,r!-

(12/88) This form (E00037) may be obtained from the Order Dept., ASM.E, 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300 REPRINT 6/93

FORM NV-1 (Pg. 2 of 3 )

Certificate Holder's Serial No. 0569C-001-1 s/n 3

1. Manufactured and certified by
2. Manufactured for First Ene Target Rock: 1966E Broadhollow Rd., E. Farmingdale, NY 11735 (name and address of NV Certificate Holder) rqy; Route 168; Shippingport, PA (nrame and afd1ess of Pu!hliaser)-
3.

Location of installation Beaver Valley Power Station; Rout 168; Shippinqport, PA (name and address)

4. Valve 0569C-001-1 Orifice size 2.443 Nom. Inlet size 6

Outlet size (Model no., sedes no.)

(in.)

(in.)

Serial No.

Material Spec.

Tensile Pressure Retaining Item or Including Type Strength Identification or Grade Main Seat 200323-1 34 SA479 304L 70 ksi Pilot Body 303839-2 1

SA479 304 75 ksi Bonnet Cap 200324-1 9

SA105 70 ksi End Uap 33830-1 4

bA4/I 3*3b

/

KSI Hex Nut 100-0076 n/a SA194 2H n/a Hex Bult 100501-1 n/a SA193 B7 125 ksi Stud 206189-2 n/a SA1 93 B7 125 ksi Stud 206189-1 n/a SA193 B7 125 ksi Stud 100482-2 n/a SA1 93 B7 125 ksi Stud 100482-1 n/a SA1 93 B7 125 ksi 6

(in.)

KiRFW KV-1

( Pg. Z3 :~u )

Certificate Holder's Serial No. 0569C-001-i s/n 3

1. Manufactured and certified by Target Rock, 1966E Broadhollow Rd.; E. Farmingdale, NY 11735 (name and address of NV Certificate Holder)
2.

Manufactured for First Enerov: Route 168: ShiDoineDort. Pa (1nwie anild drtýS of Purchasei;

3. Location of installation Beaver Valley Power Station: Route 168: Shippinarjort, PA
4.

Valve 05690-001-1 (Model no., series no.)

(name and address)

Orifice size 2.443 Nom. Inlet size 6

(in.)

(in.)

Outlet size 6

(in.)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of New York and employed by OneBeacon America Insurance Company of Boston, MA have inspected the pump, or valve, described in this Data Report on

/9 -

2o

, and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner fojr.pany personal injury or property damage or a loss of any kind arising from or n

ted with this inspectio Dat*"7*/

Signed,--"

ommissions ___

,,_/_.

__5_/___.

(Authorized Ins or)

(Nat'l. Bd.(incl. endbrsements) and state or prov. and no.)

2age 293. of.- 567)........

7Of--tM NV-i CEPTiFiCATE HFL.{DE.S' *.`-3AA REPORT FOR PRESSURE OR VACJUM R'EUEF V-1 %.ES.-.

As Required by the Provisions of the ASPAE Code, Section IJI, Division I Pg. 1 of 3

1.

Manufactured and certified by _ Target Rock; 1966E Broadhollow Rd.: E. Farminadale, NY 11735 (name and address of NV Certificate Holder)

2.

Manufactured for First Energy; Route 168: Shippincwort.PA

3.

Location of installation Beaver Valley Power Station: Route 168: Shiopinnoort, PA

4.

Valve 0569C-001-1 (Model no., series no.)

(name and address)

Orifice size 2.443 Nom. Inlet size 6

(in.)

(in Outlet size 6.

(in.)

A None.

(class)

(Code Case no.)

5.

ASME Code,Section III, Division 1:

1968 (edition)

Summer 1968 (addenda date)

6.

Type Pilot Operated 2485 120 650°F 3325 at 100'F max.

(spring, pilot or power operated) (set pressure, psig) (blowdown, psi)

(rated temp)

(hydro test,psig,inlet)

7.

Identification 6

N/A 0569C-001 Rev. D N/A 2007 (Cert. Holder's serial no.)

(CRN)

(drawing no.)

(NatlI. Bd. no.)

(year built)

8.

Control ring settings N/A

9.

Pressure retaining items:

Serial No. Or Identification Mat'l. Spec.

including Type or Grade Tensile Strength Body Bonnet or Yoke Support Rods Nozzle Disk Spring Washers Adjusting Screws Spindle Spring Bolting Other Items 342 SA351 CF8M 75 ksi 13 SA105 70 ksi 7

SA 564 630 140 ksi See pagte 2 of 3 See page 2 of 3

10. Relieving capacity 345,000 lbs/hr overpressure as certified by the National Board (69C) 10/07/2005 (date) 1 ". Remarks:

CERTIFICATOON OF DESIGN Design Specification certified by F.W. Gardner P.E. State PA Reg. No. 036614-E Design Report certified by Not applicable P.E. State N/A Reg. No.

N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-1 949 Date I

/

Name Target Rock (Certificate Holder)

Expires 12/12/2007 Signed

  • ~..

J l§BonisQA Manager (authorized representative)

  • Supplemental information in form of lists, sketches, or drawings may be used provided (1) size is 8Y2 x 11, (2) information in items 1 through 4 on this Data Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form (12/88) This form (E00037) may be obtained from the Order Dept., ASME, 22 Law Drive. Bor. 2300, Fairfield, NJ 07007-2300 REPRINT 6193
Page 294 of 567)

FORM NV-1 (Pg. 2 of 3 )

Certificate Holder's Serial No. 0569C-001 -1 s/n 6

1. Manufactured and certified by Target Rock: 1966E Broadhollow Rd.; E. Farmingdale. NY 11735 (name and address of NV Certificate Holder)

First Enerav: Route 168: Shipminciort. PA

2.

Manufactured for (name and address of Purchaser)

3.

Location of installation Beaver Valley Power Station: Rout 168: Shippinaport, PA (name and address)

4.

Valve 0569C-001-1 Orifice size 2.443 Nom. Inlet size 6

(Model no., series no.)

(in.)

(in.)

Outlet size 6

(in.)

Serial No.

Material Spec.

Tensile Pressure Retaining Item or Including Type Strength Identification or Grade Main Seat 200323-1 40 SA479 304L 70 ksi Pilot Body 303839-2 6

SA479 304 75 ksi Bonnel Cap.

200324-1 13 SA105 70 ksi End Gap J0J8,5-I 6A4/9,J1b

/b KS Hex Nut 100-0076 n/a SA-194 2H n/a Hex Bult 100501-1 n/a SA 193 7

125 ksi Stud 206189-2 n/a SA 193-B7 125 ksi Stud 206189-1 n/a SA193 B7 125 ksi Stud 100482-2 n/a SA193 B7 125 ksi Stud 100482-1 n/a SA193 B7 125 ksi

Page 295 of 567)

FORM KWNV ( Pg. 3 o,3 )

Certificate Holders Serial No. 0569C-001-1 s/n 6 Target Rock; 1966E Broadhollow Rd.; E. Farmingdale, NY 11735

{na-c-2n

....r~

I*f

!P

-! i~t nl-..:I4 -..

1. Manufactured and certified by
2.

Manufactured for First Ener v; Route 168; Shippinqport, Pa (name and address of Purchaser)

3.

Location of installation Beaver Valley Power Station: Route 168: Shippinciport. PA (name and address)

4. Valve 0569C-001-1 Orifice size 2.443 Noma. nlet size 6

Outlet size 6

(Model no., series no.)

(in.)

(in.)

(in.)

i h gCERTIFICATE OF INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of New York and employed by OneBeacon America Ins rance Company of Boston, MA have inspected the pump, or valve, described in this Data Report on

/.

n-d state that to the best of my knowledge and belief, the Certificate Holder has constructed this pufnp, or valve, in accordance with the ASME Code, Section IIl, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or properiy damage or, a loss of any kind arising from or connected with this inspecti Dat7e.

Signe Commissions A//________________

(Nat'l. Bd.(inci. endorsements) and state or prov. and no.)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3571

1. Owner FirstEnergy Nuclear Operating Company (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

I Date 10/29/2013 Sheet 1

-of Unit No.

1

2. Plant Beaver Valley Power Station (NAME)

P.O. Box 4, Shippincqport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Maintenance (NAME)

P.O. Box 4. ShiDpinaoort. PA 15077 (BVPS)

Work Order #200247037 RepairlReplacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A (ADDRESS)

Authorization No.

Expiration Date N/A N/A

4. Identification of System Safety Iniection (Q2)
5. (a) Applicable Construction Code Draft Pump & Valve 1968 Edition, __Addenda, Code Case-(b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Pump Ingersoll-0671-141 N/A 1SI-P-1B 1976 Corrected No Dresser Housing &

John Crane N/A N/A Ht. #G16674 2013 Installed No Gland Plate

7. Description of Work Installed new mechanical seal including housing and gland plate.
8. Tests Conducted:

Hydrostatic* El Pneumatic* 0 Nominal Operating Pressure [

Exempt L]

Other F1 Pressure psi Test Temp.

_F "Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report-Number 3571

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 715.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White

-. &C4 Nuclear EnqineerV Date October 29, 20 13 Owner or Owner's Uesignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period S--

-,L to

/0 - -3' 0 - / 3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

~_J Commissions AS '-'A * /,V'/ýZ,

/0,4 2,- ?

Y Inspect*rs Signature National Board, State, Province, and Endorsements D

~aie. L.......

.....,--u.....

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 ReDort Number 3576

1. Owner FirstEnerqy Nuclear Operatingq Company I Date 12/05/2013 (NAME) 76 South Main Street - Akron. OH 44308 1

(ADDRESS)

Beaver Valley Power Station (BVPS)

Sheet.

1 of 1

Unit No.

1

2. Plant (NAME)

P 0) Box 4 Shioninonort, PA 15077 Order Nos. 200434869, 200504248 3.

4.

5.

6.

(ADDRESS)

Repair/Replacement Organization P.O. No., Job No.. etc.

Work Performed By BVPS Maintenance Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippingport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A Identification of System Chemical and Volume Control (Q1)

(a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case -

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section XI Code Case(s): N/A Identification of Components Corrected, National

Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Relief Valve Crosby 61680-003 N/A RV-1CH-203 1990 Removed No Relief Valve Crosby N699721 N/A RV-1CH-203 2003 Installed No 0016 Nozzle Anderson N94955 N/A Ht. #E5ND 2002 Installed No Greenwood 0109 Crosby Disc Insert Anderson N/A N/A Ht. 74597 2003 Installed No Greenwood Crosby 5/8" Studs Trust Manuf.

N/A N/A Ht. #783582 2012 Installed No 5/8" Nuts Nova Machine N/A N/A Trace #J234 2003 Installed No

7. Description of Work Spare valve was refurbished by replacing nozzle and disc insert, and then installed as a replacement and the inlet flange studs and one nut were replaced.

Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Requi'red by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3576

8. Tests Conducted:

Hydrostatic* ]

Pneumatic* L]

Nominal Operating Pressure 0 Exempt El Other [L Pressure psi Test Temp.

.OF

  • Record test pressure and temperature
9. Remarks No Code Data Report available. ASME Section VIII relief valve installed into an ANSI B31.1 system.

' Applicable Manufacturer's Data Reports to be attached Previous NIS-2 Data Report No. 3303.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Enqineer V Date December 27, 20 13 Owner or Owner's besignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure.Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period to-/L-to

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspe SC mis Signature National Board, State, Province, and Endorsements Date

/-/0

, 20 1Y Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3578

1. Owner FirstEnergy Nuclear Operating Company Date 12/23/2013 (NAME) 76 South Main Street-Akron, OH 44308 Sheet 1

of 1

(ADDRESS)"

Unit No.

1

2. Plant.

Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippinqport, PA 15077 Order #200504250 (ADDRESS)

Repair/Replacement Organization P.O. No., Job No., etc.

3. Work Performed By BVPS Maintenance Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippingport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Chemical and Volume Control (Q1)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case--

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Relief Valve Crosby N89695 N/A RV-1CH-391 1976 Corrected No 0002 Spring &

Crosby K91279 N/A N/A 1998 Installed No Washer Assy 0002 Disc Insert Anderson N97068-NEE N/A Ht. #1810 3 2004 Installed No Greenwood 1049 Crosby

7. Description of Work Replaced disc insert, spring and washer assembly.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* E]

Nominal Operating Pressure El Exempt Z Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3578 Other El Pressure psi Test Temp.

oF

  • Record test pressure and temperature
9. Remarks No Code Data Reports available. Valve isSection VIII installed into an ANSI B31.1 line.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date December 23, 20 13 Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5-. // -/,

to

/1-r--73

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

J& 2,,

Commissions t~

'~,

&4

/

Inspectxs Signature National Board, State, Province, and Endorsements Date

/-1(-

,20 IV Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Report Number 3581

1. Owner FirstEnerqy Nuclear Operating Company (NAME) 76 South Main Street - Akron, OH 44308 I Date 12/26/2013 (ADDRESS)

Beaver Valley Power Station (BVPS)

Sheet 1

of I

Unit No.

1 Order #200508880

2. Plant P.O. Box 4, (NAME)

Shippingport. PA 15077 (ADDRESS)

3. Work Performed By BVPS Maintenance (NAME)

P.O. Box 4. ShiDDinaODort. PA 15077 Repair/Replacement Organization P.O-No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A (ADDRESS)

I Expiration Date

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case-(b) -Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 2001E-2003A (c) Applicable Section XI Code Case(s):
6. Identification of Components N/A Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped

-Component--

Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Check Valve C & S Valve 92-2019-N/A 1RW-106 Removed No 06(Q)-i Check Valve Crane D2088 N/A 1RW-106 1976 Installed No 1-1/4" Stud Nova Machine N/A N/A Trace #X573 2006 Installed No 1-1/4" Nut Nova Machine N/A N/A Trace #P921 2005 Installed No 1-1/4" Nut Nova Machine N/A N/A Trace #S697 2005 Installed No 1-1/4" Nut Nova Machine N/A N/A Trace #3J23 2009 Installed No 1-1/4" Nut Nova Machine N/A N/A Trace #S697 2006 Installed No

7. Description of Work Replaced valve, studs and nuts.

Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3581 8.. Tests Conducted:

Hydrostatic* E]

Pneumatic* El Nominal Operating Pressure 0 Exempt L]

Other FI Pressure psi Test Temp.

oF

'Record test pressure and temperature

9. Remarks No Code Data Reports available. Previous NIS-2 Data Report No. 3236.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date January 06, 20 14 Owner or Owner's esignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected thecomponents described in this Owner's Report during the period 5-- /,(-

to

/I -

/- /.?

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Z Commissions 9

,4'

  • L

`4 l-j* q J" ? r V Inspeptr's Signature National Board, State, Province, and Endorsements Date

/U-

,20

/

V Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-Q2 Rev. 01 Report.Number 3.53

1. Owner FirstEnergy Nuclear Operating Company L Date 01/03/2014 (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

Beaver Valley Power Station (BVPS)

Sheet Unit No.

1 of 1

2. Plant PO_~ Box 4~

(NAME)

Shirnninainort_ PA 15077 Order #200502886 (ADDRESS).

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, ShippinaDort, PA 15077 Repair/Replacement Organization P.O. No.. Job No.. etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A (ADDRESS)

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case -_

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Butterfly Allis Chalmers 92361-3 N/A MOV-1RW-1993 Removed No Valve 102B2 Butterfly Velan 610903-1 N/A MOV-1RW-2012 Installed No Valve 102B2 Spacer Plate Velan N/A N/A Ht. #5DRK 2013 Installed No 1-1/8" Nut Nova Machine N/A N/A Trace #7N06 2013 Installed No 1-1/8" Nut Nova Machine N/A N/A Trace #4S99 2010 Installed No j-1/8" Stud Trust Manuf.

N/A N/A Trace #SS15 20 ]12 Installed No

7. Description of Work Replaced valve, spacer, studs and nuts.
8. Tests Conducted:

Hydrostatic* L]

Pneumatic* L]

Nominal Operating Pressure 0 Exempt E]

Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-570-2R e-v-01---

Report Number 3583.

÷ Other E1 Pressure psi Test Temp.

= F

  • Record lest pressure and temperature
9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 440. Replacement valve designed in Applicable Manufacturer's Data Reports to be attached accordance with ANSI B31.1 2010E.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date January 03, 20 14 Owner or Owner's Ekesignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

.5-5-/ -/,,--

to

/( - 1./.

/3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied,

-concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4

2. 17,a, Commissions A.d F
4X K i-,-15-A-1,4 b

7_3 "

InspectoKSignature -.-

---Natienal Board, State, Province, and Endorsements=--

Date

,(-

20 I_

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 3-02 Rev. 01 Report Number 3608 NOP-CC-570;

1. Owner FirstEnergy Nuclear Operating Company (NAME)

Date 12/18/2013 76 South Main Street - Akron, OH 44308 (ADDRESS)

Sheet 1

of Unit No.

1

2. Plant Beaver Valley Power Sta (NAME)

P.O. Box 4, Shippincport, PA 15077 tion (BVPS'l tion (B1./PM (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shiorinaoort. PA 15077 Order #200513520 Repair/Replacement Organization P.O. No., Job No., etc-Type Code Symbol Stamp N/A (ADDRESS)

Authorization No.

Expiration Date N/A N/A

4. Identification of System Safety Injection (Q2)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case ---

(b)

Applicable Edition of Section Xi Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section Xi Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Snubber Grinnell 8396 N/A SI-HSS-519 2000 Removed No Snubber Basic PSA 45550 N/A SI-HSS-519 2013 Installed No

7. Description of Work Replaced snubber.
8. Tests Conducted:

Hydrostatic* L]

Pneumatic* E]

Nominal Operating Pressure El Exempt 0 Other El Pressure psi Test Temp.

_F

  • Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3608

9. Remarks No Code Data Reports available. Previous NIS-2 Data Report No. 1500. Replacement snubber Applicable Manufacturer's Data Reports to be attached supplied as ANSI B31.1 1967E-S'73A.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date December 18, 20 13 Owner or Owner'sDesignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period f-r/'--

to

//-

5/- /3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the--.

inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

'-*f'*J'Y r

Commissionsd -/Z

,,A,{Z-f Inspectls Signature National Board, State, Province, and Endorsements Date

-/.20

/..-2 Page 2 of 2

FORM MS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3609

1. Owner FirstEnergy Nuclear Operating Company Date 12/06/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

Unit No.

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippingport, PA 15077 Order #200513523 (ADDRESS)

Repair/Replacement Organization P.O No., Job No.. etc.

3. Work Performed By BVPS Construction Services Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippingport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Main Steam (Q2)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case ----

(b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Snubber Grinnell 30757 N/A SHP-HSS-209 2001 Removed No Snubber Lisega 31300150/006 N/A SHP-HSS-209 2013 Installed No

7. Description of Work Replaced snubber.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* LI Nominal Operating Pressure LI Exempt [

Other F1 Pressure

.psi Test Temp.

"Record test pressure and temperature

- F Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-57-3-02Rekv-01 Repbrt-Number 736

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 1493. Replacement snubbers Applicable Manufacturer's Data Reports to be attached supplied as ANSI B31.1 1967E-S'73A.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed Thomas White d 2 Expiration Date N/A Nuclear EngineerV Date December 06, 20 13 Owner or Owner's besignee,- Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

- //-/,J--

to

// - K-12

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

24 Commissions Jdý°2-84,2 Z -

,44 x--

Ins Vtor's Signature National Board, State, Province, and Endorsements

-Date.

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTRVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number i6-0

1. Owner FirstEnerqy Nuclear Operatinq Company (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)
2. Plant Beaver Va ley Power Station (BVPS)

(NAME)

P.O. Box 4. ShiDoincoort. PA 15077 I Date 12/06/2013 Sheet 1

of 1

-Unit No.

1 Order #200513524 (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippinqport, PA 15077 (ADDRESS)

Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A

4. Identification of System Main Steam (Q2)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case ---

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section Xl Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other' Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Snubber Grinnell 8849 N/A SHP-HSS-210 1976 Removed No Snubber Lisega 31300150/012 N/A SHP-HSS-210 2013 Installed No

7. Description of Work Replaced snubber.
8. Tests Conducted:

Hydrostatic* E Pneumatic* E]

Nominal Operating Pressure LI Exempt Z Other nI Pressure psi Test Temp.

O F

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP:CC-5703-02 Rev. 01 Repoi 0hm6F 361

9. Remarks No Code Data Report available. Replacement snubber supplied as ANSI B31.1 1967E-S'73A.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.° Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date December 12, 20 13 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

.S"-

/ (- /

to

/ (

- /3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employ, makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected W* this inspection.

Q-,

J I

Commissions,J' 9'-/- g *-JLF.4' A1.

lnspefor's Signature National Board, State, Province, and Endorsements Date

, 20/.?

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 3-02 Rev. 01 Report Number 3611 NOP-CC-570:

1. Owner FirstEnerqy Nuclear Operatinq Company I Date 12/06/2013 (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)
2. Plant P.O. Box 4, Beaver Valley Power Station (BVPS)

Sheet 1

of 1

i..Init No.-.

  • i Order #200513528 (NAME)

Shippincport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippinqport, PA 15077 (ADDRESS)

Repair/Replacement Organization P No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

Expiration Date N/A N/A

4. Identification of System Main Steam (Q2)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case ----

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Snubber Grinnell 19826 N/A SHP-HSS-211 2005 Removed No Snubber Lisega 31300150/003 N/A SHP-HSS-211 2013 Installed No

7. Description of Work Replaced snubber.
8. Tests Conducted:

Hydrostatic* [

Pneumatic* []

Nominal Operating Pressure El Exempt [J Other FI Pressure psi Test Temp.

° F "Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Wo.

Reit Number 3611-

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 1776. Replacement snubbers Applicable Manufacturer's Data Reports to be attached supplied as ANSI B31.1 1967E-S'73A.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed Thomas White Owner or Owner's Designee, Title Expiration Date N/A Nuclear Enqineer V Date December 06, 20 13 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

"-J //-(

to

// - ý'- / 3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected wit this inspection.

4%-

_. 4'i Commissions

,J-

,4 y

,nsp2_or's Signature National Board, State, Province, and Endorsemf


. Date-

,20- /2 ents Insp*r's Signature Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Repo-rt Wumbrf 3612

1. Owner FirstEnerav Nuclear Ooeratino Comoanv I Date 12/11/2013 (NAME) 76 South Main Street - Akron. OH 44308 Sheet Unit No.

(ADDRESS) 1 of 1_I 1

2. Plant Beaver Valley Power St*

(NAME)

P.O.RBo 4 Shinninanort PA 15077 ation (BVPS)

(ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, ShipDinaport, PA 15077 Order #200513529.

RepairlReplacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A (ADDRESS)

Authorization No.

Expiration Date N/A N/A

4. Identification of System Main Steam (Q2)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case ---

(b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section Xl Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Snubber Grinnell 19824 N/A SHP-HSS-212 1976 Removed No Snubber Lisega 31300150/002 N/A SHP-HSS-212 2013 Installed No

7. Description of Work Replaced snubber.
8. Tests Conducted:

Hydrostatic* Li Pneumatic* E]

Nominal Operating Pressure L]

Exempt M Other Li Pressure psi Test Temp.

_F "Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI OP-CC-.57G d-0 7e.0'l... -:-"-

.. R -p N,**--

9. Remarks No Code Data Report available. Replacement snubbers supplied as ANSI B31.1 1967E-S'73A.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White

  • Q.

Nuclear Engqineer V Date December 11, 20 13

.Owner or Owner's Destg nee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

,7- (1'

/-

/,

to

/ ( - V -

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and correctivemeasures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

L

_Commissions AV;2* 3 g5 9' lnspec

  • Signature National Board, State, Province, and Endorsements Date

/0- -1/7-

,20

/ -_

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3613

1. Owner FirstEnergy Nuclear Operating Company I Date 12/11/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippinqport, PA 15077 Order #200513530 (ADDRESS)

RepairlReplacement Organization P.O. No.. Job No-, etc.

3. Work Performed By BVPS Construction Services Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippingport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Main Steam (02)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case -

(b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or.

Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No).

Snubber Grinnell VB-7199 N/A SHP-HSS-1976 Removed No 214A Snubber Lisega 31300150/006 N/A SHP-HSS-2013 Installed No 214A

7. Description of Work Replaced snubber.
8. Tests Conducted:

Hydrostatic* LI Pneumatic* E]

Nominal Operating Pressure [L Exempt 0 Other L]

Pressure psi Test Temp.

_F

  • Record test pressure end temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3613

9. Remarks No Code Data Report available-Replacement snubbers supplied as ANSI B31.1 1967E-S'73A.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date December 18, 20 13 Owner or Owner's Iesignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5- //A,--

to 1/-

1-1/2

, and state that to the

  • best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___Z Commissions

,7*

4 4 #T-,-_*

/A,L3 ?Y Inspec s Signature National Board, State, Province, and Endorsements Date 20 1-3 Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3614

1. Owner FirstEnerqy Nuclear Operatinq Company (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)
2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippingport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4. Shippinarort, PA 15077 I Date 12118/2013 Sheet 1

of Unit No.

I Order #200513532 RepairlReplacement Organization P.O. No. Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A 4.

5.

6.

(ADDRESS)

Expiration Date N/A Identification of System Reactor Coolant (Q1)

(a) Applicable Construction Code ANSI 831.1 1967 Edition, S'71 Addenda, Code Case--

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section XI Code Case(s): N/A Identification of Components Corrected, National

Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Snubber Grinnell VB-7458 N/A RC-HSS-302 2003 Removed No Snubber Lisega 31200815/041 N/A RC-HSS-302 2013 Installed No

7. Description of Work Replaced snubber.
8. Tests Conducted:

Hydrostatic* El Pneumatic* E]

Nominal Operating Pressure LI Exempt [

Other nl Pressure psi Test Temp.

°_F

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Report Number 3614

9. Remarks No Code Data Report available. Replacement snubbers supplied as ANSI B31.1 1967E-S'73A.

Applicable Manufacturer's Data Reports to be attached Previous NIS-2 Data Report No. 1627.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed Thomas White Owner or Owner's Designee, Title Expiration Date N/A Nuclear EngineerV Date December 18, 20 13 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

.--- //-

-,')

to

//-

V'- *'?, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Insp*Xors Signature Commissions

-T-S-

National Board, State, Province, and Endorsements Date I/d -/?-

, 20 /-?

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTiVITY As Required by the Provisions of the ASME Code Section XI S-NO-CC-570"T-02Rev- 01

.R6-ort1--b-3-r-66

1. Owner FirstEnerqy Nuclear Operatinq Company Date 12/14/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippinqport, PA 15077 Order #200513536 (ADDRESS)

Repair/Replacement Organization P-O. No., Job No., etc.

3. Work Performed By BVPS Construction Services Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippinqport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Reactor Coolant (Q1)
5. (a) Applicable Construction Code ANSI 831.1 1967 Edition, S'71 Addenda, Code Case -

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section X1 Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Snubber Grinnell 22170 N/A RC-HSS-3 2000 Removed No Snubber Lisega 31300013/037 N/A RC-HSS-3 2013 Installed No

7. Description of Work Replaced snubber.
8. Tests Conducted:

Hydrostatic* []

Pneumatic* El Nominal Operating Pressure [1 Exempt 0 Other []

Pressure psi Test Temp.

_F

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 1287. Replacement snubbers Applicable Manufacturer's Data Reports to be attached supplied as ANSI B31.1 1967E-S'73A.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed Thomas White tZ Owner or Owner's Designee, Title Expiration Date N/A Nuclear EnqineerV Date December 14, 20 13 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

-//-/,)--

to

// L-zV

/./-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his-e-mployer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

  • ' I Commissions*.LYV,-

-JrýJ I nspectoX Signature National Board, State, Province, and Endorsements Date

/d-- -I?

,20

/2 Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3617

1. Owner FirstEnerqy Nuclear Operating Company Date 12/14/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

.(NAME)

P.O. Box 4, Shippinciport, PA 15077 Order #200513538 (ADDRESS)

Repair/Replacement Organization P.O. No.. Job No.. etc.

3. Work Performed By BVPS Construction Services Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippingport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Reactor Coolant (01)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 AddenaIa, Code Case
  • (b)

Applicable Edition of Section X1 Utilized for Repair/Replacement Activity 2001E-2003A (c)

Applicable Section Xi Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Snubber Grinnell VB-7238B N/A RC-HSS-4

.2000 Removed No Snubber Lisega 31300013/038 N/A RC-HSS-4 2013 Installed No

7. Description of Work Replaced snubber.
8. Tests Conducted:

Hydrostatic* L]

Pneumatic* E Nominal Operating Pressure [

Exempt Z Other n Pressure psi Test Temp. -

F

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3617

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 1279. Replacement snubbers Applicable Manufacturer's Data Reports to be attached supplied as ANSI B31.1 1967E-S'73A.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of. the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Sinpnd Thomas White Expiration Date N/A Nuclear Engineer V Date December 14, 20 13 v,*:/

Owner or Owner'"V*signee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

/-

/ *-

to

//-

S/--?

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage~or a loss of any kind arising, from or connected with this inspection.

Commissions k.),Ak

-,2 g-(

National Board, State, Province, and Endorsements Date

/ ;ýP_ - J 9 -

1 20 / --?

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3620

1. Owner FirstEnerav Nuclear Operatinci Company I Date 12/18/2013 (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

Sheet Unit No.

1 of 1

2. Plant Beaver Valley Power St*

(NAME)

P.O. Box 4. ShiDoinaDort. PA 15077 ation (BVPS)

Order #200513543 (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippinciport, PA 15077 Repair/Replacement Organization P-0. No., Job No., etc.

-Type Code Symbol Stamp N/A Authorization No.

N/A 4.

5.

6.

(ADDRESS)

I Expiration Date N/A Identification of System Residual Heat Removal (Q1)

(a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case --

(b) Applicable Edition of Section X1 Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section Xl Code Case(s): N/A Identification-of Components Corrected, National

Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Snubber Grinnell 31970.

N/A RH-HSS-124 1999 Removed No Snubber Lisega 31200705/018 N/A RH-HSS-124 2013 Installed No

7. Description of Work Replaced snubber.
8. Tests Conducted:

Hydrostatic* LI Pneumatic* LI Nominal Operating Pressure LI Exempt 0 Other nI Pressure psi Test Temp.

° F

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Report Number 3620

9. Remarks No Code Data Report available. Replacement snubbers supplied as ANSI B31.1 1967E-S'73A.

Applicable Manufacturer's Data Reports to be attached Previous NIS-2 Data Report No. 1117.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White 1

Nuclear Engineer V Date December 18, 20 13 Owner or Owner's r~esignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period t-(I/- /,2 to j(( -

-/ 3 -' and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this ce'rtificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions aIS*/9,O-?, '.4._U&

A*f- 0L..

Insp or's Signature National Board, State, Province, and Endorsements Date

/,).-

7 -

, 20 /_-

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 ReDort Number 3621

1. Owner FirstEnerav Nuclear ODeratina Comoanv (NAME)

Date 12/18/2013 Sheet 1

of Unit No.

1 76 South Main Street - Akron. OH 44308 (ADDRESS)

2. Plant Beaver Valley Power St*

(NAME)

P.O Box 4 Shinninaoort_ PA 15077 ation (BVPSi (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippinqport, PA 15077 Order #200513555 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A (ADDRESS)

Authorization No.

Expiration Date N/A N/A

4. Identification of System Recirculation Spray (Q2)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case --

(b)

Applicable Edition of Section Xi Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Snubber Grinnell VB-7197 N/A RS-HSS-221 2001 Removed No Snubber Lisega 31200884/015 N/A RS-HSS-221 2013 Installed No

7. Description of Work Replaced snubber.
8. Tests Conducted:

Hydrostatic* []

Pneumatic* E]

Nominal Operating Pressure LI Exempt 0 Other LI Pressure psi Test Temp.

_F

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3621

9. Remarks No Code Data Report available. Replacement snubbers supplied as ANSI B31-1 1967E-S'73A.

Applicable Manufacturer's Data Reports to be attached Previous NIS-2 Data Report No. 1495.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed Thomas White Owner or Owner's esignee, Title Expiration Date N/A Nuclear Engineer V Date December 18, 20 13 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

.J--

to

// - V-,"3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

/ K.... J Commissions,/J&,

7,,z.

d

,A 3 V-

  • Inspe !

s Signature National Board, State, Province, and Endorsements Date IdL-/,20

/?

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1 NOP-CC-5703-02 Rev. 01 Report Number 3624

1. Owner FirstEnemv Nuclear Operatinq Company I Date 12/18/2013 (NAME) 76 South Main Street -Akron, OH 44308 (ADDRESS)

Sheet Unit No.

1 of 1

2. Plant Beaver Valley Power Stz (NAME)

P.O. Box 4. ShiorinaDort. PA 15077 ation (BVPS)

Order #200513562 (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippinqport, PA 15077 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A 4.

5.

6.

(ADDRESS)

Expiration Date N/A Identification of System Safety Injection (Q2)

(a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case -

(b) Applicable Edition of Section Xi Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section XI Code Case(s): N/A Identification of Components Corrected, National

Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Snubber Grinnell 22189 N/A SI-PSSP-3 1976 Removed No Snubber Lisega 31300013/031 N/A SI-PSSP-3 2013 Installed No

7. Description of Work Replaced snubber.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* LI Nominal Operating Pressure El Exempt ED Other L]

Pressure psi Test Temp.

°OF

  • Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3624

9. Remarks No Code Data Report available. Replacement snubbers supplied as ANSI B31.1 1967E-S'73A.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE_

I certify that the statements made in the report are correct and that this conf6i0nd.t the requirements of the ASME Code, Section.XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Si9n ~

Thomas White J~ )Nuclear Engineer VDate December 18, 20 13 Owner or Owner's-Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

...5- /1- /(O-to

// - V -/-/

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

1-*

j/*

', 2 y Commissions /J,/,o')-

/9,df..9L--

Inspects Signature National Board, State, Province, and Endorsements Date

-,L-/7-

,20

/-

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3625

1. Owner FirstEnergy Nuclear Operating Company (NAME) 76 South Main Street - Akron, OH 44308 I Date 12/06/2013 (ADDRESS)

Beaver Valley Power Station (BVPS)

Sheet Unit No.

1 of 1

1

2. Plant P.O. Box 4.

(NAME)

ShipDinaport. PA 15077 Order #200513564 (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippingport, PA 15077 (ADDRESS)

Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A

4. Identification of System Safety Injection (02)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71A Addenda, Code Case ---

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity *N"A L...*

(c)

Applicable Section Xt Code Case(s): h.,I41

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Snubber Grinnell 25920 N/A SI-PSSP-36A 1976 Removed No Snubber Lisega 31300013/036 N/A SI-PSSP-36A 2013 Installed

. No

7. Description of Work Replaced snubber.
8. Tests Conducted:

Hydrostatic* El Pneumatic* LI Nominal Operating Pressure El Exempt 0 Other E]

Pressure psi Test Temp.

o F

  • Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1 NOP-CC-5703-02 Rev. 01 Report Number 3625 -

9. Remarks No Code. Data Report available. Previous NIS-2 Data Report No. 471. Replacement snubber Applicable Manufacturer's Data Reports to be attached supplied as ANSI B31.1 1967E-S'73A.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date December 06, 2013 Owner or Owner's lesignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period j--//-

/ 2-to

/ -

1'-23

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied; concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions,7.'62 o-T,,4-'.-

lnspet6 r's Signature National Board, State, Province, and Endorsements

-Date-.

-/ d-

20.

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3626

1. Owner FirstEnerqy Nuclear Operating Company (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

I Date' 12/18/2013 Sheet 1

of Unit No.

1

2. Plant Beaver Valley Power St (NAME)

P.O. Box 4, Shippinaport, PA 15077 ation (BVPS)

Order #200513567 (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4. ShiDDinaDort. PA 15077 RepairlReplacement Organization P.O. No-, Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A (ADDRESS)

4. Identification of System Safety Injection (Q2)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S71 Addenda, Code Case --

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Snubber Grinnell 22179 N/A SI-PSSP-2 2005 Removed No Snubber Lisega 31300013/035 N/A SI-PSSP-2 2013 Installed No

7. Description of Work Replaced snubber.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* EL Nominal Operating Pressure El Exempt 2 Other [l Pressure psi Test Temp.

°_F

  • Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3626

9. Remarks No Code Data Report available. Replacement snubbers supplied as ANSI B31.1 1967E-S'73A.

Applicable Manufacturer's Data Reports to be attached Previous NIS-2 Data Report No. 1831.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate Signed of Authorization No.

N/A Thomas White Expiration Date N/A Nuclear EngqineerV Date December 18, 20 13 Thomas White Owner or Owner's'Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

_.--//-",-

to

//- 9--/i

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

/-&ý-J-"

2 Commissions 4,-

/f Inspec$ts Signature f

National Board, State, Province, and Endorsements Date

,20

/-?

Page 2 of 2

NOP-CC--570 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl 3-02 Rev. 01 Report Number 3627

1. Owner FirstEnerav Nuclear Operatino Companv I Date 12/18/2013 (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

Sheet Unit No.

1 of 1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4. ShiooinaDort. PA 15077 Order #200513576 (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippinqport, PA 15077 (ADDRESS)

Repair/Replacement Organization P.O. No., Job No.. etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A

4. Identification of System Safety Iniection (02)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case ---

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-20Q3A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Snubber Grinnell 12169 N/A SI-HSS-516A.

1976 Removed No Snubber Basic PSA 45548 N/A SI-HSS-516A 2013 Installed No

7. Description of Work Replaced snubber.
8. Tests Conducted:

Hydrostatic* El Pneumatic* E]

Nominal Operating Pressure [L Exempt Z Other Li Pressure psi Test Temp.

oF "Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3627

9. Remarks No Code Data Reports available. Replacement snubber supplied as ANSI B31.1 1967E-S'73A.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear EngineerV Date December 18, 20 13 Owner or Owner's besignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owners Report during the period L

-L2Z to

(

1-

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_2_

1

__Z_

Commissions A

,,Y*K 7 A.'

Inspec s Signature National Board, State, Province, and Endorsements Date

. 20/i Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3628

1. Owner FirstEnery Nuclear Ooeratinq Company I Date 12/18/2013 (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

Sheet 1

of Unit No.

1 Order #200513579

2. Plant Beaver Valley Power St*

(NAME)

P.O. Box 4. Shippinaciort. PA 15077 ation (BVPS)

(ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

PO. Box 4-ShioDinaDort PA 15077 Repair/Replacement Organization P.O. No.. Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A 4.

5.

6.

(ADDRESS)

A Expiration Date N/A Identification of System Safety Injection (Q2)

(a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case __

(b) Applicable Edition of Section X1 Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A Identification of Components Corrected, National

Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Snubber Grinnell 23525 N/A SI-HSS-516B 1999 Removed No Snubber Basic PSA 45549 N/A SI-HSS-516B 2013 Installed No

7. Description of Work Replaced snubber.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* El Nominal Operating Pressure LI Exempt [

Other nI Pressure psi Test Temp.

_F

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3628

9. Remarks No Code Data Reports available. Replacement snubber supplied as ANSI B31.1 1967E-S'73A.

Applicable Manufacturer's Data Reports to be attached Previous NIS-2 Data Report No. 1107.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear EngineerV Date December 18, 20 13 Owner or Owner's [.Tesignee,-Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 1,-2--

/,2-to

/ / - L - / 3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__y Commissions WIz V

V 1/",9

-,?'y Insp ors Signature National Board, State, Province, and Endorsements Date

, 20,/

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3629

1. Owner FirstEnerqy Nuclear Operatinq Company Date 12/20/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippincport, PA 15077 Order #200503474 (ADDRESS)

Repair/Replacement Organization P.O-No., Job No., etc.

3. Work Performed By BVPS Construction Services Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippingqport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case -.-

(b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 2001E-2003A (c) Applicable Section X1 Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Ball Valve Anchor/Darling EZ603-1-6 N/A 1RW-144 1995 Corrected No End Piece Flowserve N/A N/A Trace 2013 Installed No

  1. 2930/4 End Piece Flowserve N/A N/A Trace 2013 Installed No
  1. 2831/2 3" Tee Energy &

N/A N/A Ht. #LZSR-3 2003 Installed No Process

7. Description of Work Replaced valve end pieces and tee.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* LI Nominal Operating Pressure [

Exempt LI Other LI Pressure psi Test Temp.

OF Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3629

'Record test pressure and temperature

9. Remarks No Code Data ReDorts available. Previous NIS-2 Data Report No. 905.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

Signed Thomas White N/A (Aý- ý Expiration Date N/A Nuclear Engineer V Date December 20, 20 13 Owner or Owner's Des4gnee,, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period to I-S/ - / -3, and state that to the

-best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

~ 2~

CommissionsJ~~,.

AA

-d? ýv-lnspectýK Signaturie National Board, State, Province, and Endorsements Date

"-/0 120 /i Y Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3630

1. Owner FirstEnerqy Nuclear Operating Company I Date 12/04/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippinqport, PA 15077 Work Order #200504115 (ADDRESS)

Repair/Replacement Organization P.O. No., Job No., etc.

3. Work Performed By BVPS Construction Services Type Code Symbol Stamp N/A (NAME)

_.P_.O-Box.4,.Shippinqport, PA 15077...

Authorization. No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case -

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section Xl Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Ball Valve Anchor EZ603-1-9 N/A 1RW-137 1995 Corrected No Darling End Piece Flowserve N/A N/A Trace 2013 Installed No

  1. 2930/3 End Piece Flowserve N/A N/A Trace 2013 Installed No
  1. 2831/1 3" NPS Pipe Energy &

N/A N/A Ht. #812008 2003 Installed No Process

7. Description of Work Repiaced valve end pieces and pipe nipples.
8. Tests Conducted:

Hydrostatic* []

Pneumatic* E3 Nominal Operating Pressure 2 Exempt 13 Other LI Pressure psi Test Temp.

°_F

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1 NOP-CbC-5703-02 Rev. 01 Report iNu0mber 3630

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 3142.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date December 13, 20 13 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

.5--//-/,

to

// -

-'3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

n e

Commissions,, /A,?'

R nspecs SignNational Board, State, Province, and Endorsements

-_ a e...

. _, = * / 2 *

-* 0 -

  • 3..

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3631

1. Owner FirstEner-gy Nuclear Operating Company Date 12/20/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippincqport, PA 15077 Work Order #200504124 (ADDRESS)

Repair/Replacement Organization P.O. No., Job No., etc.

3. Work Performed By BVPS Construction Services Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippincport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case--

(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section X1 Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Ball Valve Anchor EZ603-1-7 N/A 1RW-142 1995 Corrected No Darling End Piece Flowserve N/A N/A Trace 2013 Installed No

  1. 2830/2 End Piece Flowserve N/A N/A Trace 2011 Installed No
  1. 102361A-2 3" Tee Energy &

N/A N/A Ht. #MZPX-1 2013 Installed No Process 3" Elbow Energy &

N/A N/A Ht. #LZSR-2 2003 Installed No Process 3" NPS Pipe Energy &

N/A N/A Ht. #812008 2003 Installed No Process

7. Description of Work Replaced valve end pieces, tee, elbow, and pipe nipple.

Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Report Number 3631

8. Tests Conducted:

Hydrostatic* Li Pneumatic* E]

Nominal Operating Pressure 0 Exempt E]

Other LI Pressure psi Test Temp.

OF

'Record test pressure and temperature

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 3143.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed Thomas Whit Owner or Owner's Designee, Title Expiration Date N/A Nuclear Enqineer V Date December 20, 20 13 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

.-- /1-/,

to i (- V-3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

L7I2,4JL Commissions Jd 7VpLO -/,.6 1xL3 ý V Inspecto* Signature National Board, State, Province, and Endorsements Date

/-1/0-

, 20 /

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01

.. Report Number 3633

1. Owner FirstEnerv Nuclear ODeratina Comoanv Date 01/03/2014 (NAME) 76 South Main Street - Akron. OH 44308 Sheet of 1

%ý'

1 Unit No.

1

2. Plant Beaver Valley Power-St=

(NAME)

P.O. Box 4. Shioninaoort. PA 15077 ation (BVPS)

Order #200418390 (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippinqport, PA 15077 RepairlReplacement Organization P.O. No.. Job No.. etc.

Type Code Symbol Stamp N/A Authorization No.

N/A 4.

5.

(ADDRESS)

Expiration Date N/A Identification of System River Water (Q3)

(a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case ---

(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A Identification of Components 6.

Corrected, National

Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Butterfly Allis Chalmers 92361-2 N/A MOV-1RW-1993 Removed No Valve 102A2 Butterfly Velan 610903-3 N/A MOV-1RW-2012 Installed No Valve 102A2 Spacer Plate Velan N/A N/A Ht. #5DID 2012 Installed No 1-1/8" Nut Nova Machine N/A N/A Trace #4S99 2010 Installed No 1-1/8" Stud Trust Manuf.

N/A N/A Trace #SS13 2012 Installed No 1-1/8" Stud Trust Manuf..

N/A N/A Trace #SS1 55 2012 Installed No.

1-1/8" Stud Trust Manuf.

N/A N/A Trace #JJ20 2010 Installed No 1-1/8" Stud Trust Manuf.

N/A N/A Trace #SSl 1 2012 Installed No Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI N0P-CC-5703-02Re--.- -

Report Number--36-3 -..

7. Description of Work Replaced valve, spacer, studs and nuts. Previous NIS-2 Data Report No. 1034.

1~-~

[

8. Tests Conducted:

Hydrostatic* EL Pneu Other L]

Pressure

  • Record test pressure and temperature matic* F]

Nominal Operating Pressure M Exempt LI psi Test Temp.

° F

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 1034. Replacement valve designed Applicable Manufacturer's Data Reports to be attached in accordance with ANSI B31.1 2010E.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed Thomas White Expiration Date N/A Nuclear Engineer V Date January 08, 20 14 Owner or Owner s D16signee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5-- -/-/_.

to

// 1-3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

/9&e-<J.2,1ýY Commissions 9-c('4" 4'F

,400,L3 -Y' Inspoftor's Signature National Board, State, Province, and Endorsements

/-/o -1$'-

Page 2 of 2

FORM NýS-2 OWNER'S REPORT FOR REPAGRS/REPLACEMENT ACTMVTY As Required by the Provisions of the ASME Code Section XI 3-02 Rev. 01 Report Number 3634 NOP-CC-570

1. Owner FirstEnergy Nuclear Operatinq Company I Date 12/05/2013 (NAME) 76&South Main Street -Akron, OH"44308... *"

(ADDRESS)

2. Plant Beaver Valley Power Station (NAME)

P.O. Box 4, Shippingport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Valve Team (NAME)

P.O. Box 4. Shippinaport, PA 15077

'Sheet 1

-of 1

Ilnit No Work Order #200432754 (R\\BVPS*

(BVPS)

Repair/Replacement Organization P.O. No.. Job No., etc.

Type Code Symbol Stamp N/A (ADDRESS)

Authorization No.

Expiration Date N/A N/A

4. Identification of System Feedwater (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case-(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Gate Valve Crane N/A 1FW-36 1976 Corrected No 7/8" Stud Nova Machine N/A N/A Trace #8E34 2013 Installed No

7. Description of Work Replaced body to bonnet nuts.
8. Tests Conducted:

Hydrostatic* LI Pneumatic* LI Nominal Operating Pressure El Exempt 0 Other F-1 Pressure psi Test Temp.

°_F Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITr(

As Required hy the Provisions of the ASME Code Section XI NOP-CC-570i-02 Rev:- 01 -.

Report Nurbu;*.3634

9. Remarks No Code Data Report available.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Enqineer V Date December 05, 20 13 Owner or Owner's besibnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

.5--//-/--

to

,Ltzj

/Ti

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ý-

Commissions rJi 9~

~

A2~

9 InspeWs Signature National Board, State, Province, and Endorsements

-Date

,. 2 _11 Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Report Number 3635

1. Owner FirstEnerqy Nuclear Operatinq Company I Date 01/03/2014 (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

Sheet 1

of Unit No.

1

2. Plant Beaver Valley Power St*

(NAME)

P.O. Box 4, Shippinwport, PA 15077 ation (BVPS)

(ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippincport, PA 15077 (ADDRESS)

Order #200436325 RepairlReplacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case-(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Butterfly Valve Rodney Hunt 1

N/A MOV-1RW-103A 1993 Removed No Butterfly Valve Velan 611014-1 N/A MOV-1RW-103A 2013 Installed No 1-1/4" Stud Trust Manuf.

N/A N/A Trace #KK70 2011 Installed No 1-1/4" Nut Trust Manuf.

N/A N/A Trace #KK41 2011 Installed No 1-1/4" Nut Trust Manuf.

N/A N/A Trace #CC16 2010 Installed No Spacer Plate Velan N/A N/A Ht. #5DSA 2013 Installed No

7. Description of Work Replaced valve, spacer, studs and nuts.
8. Tests Conducted:

Hydrostatic* LI Pneumatic* El Nominal Operating Pressure []

Exempt [l Other LI Pressure psi Test Temp.

°_F Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1 NOP-CC-5703-02 Rev. 01 Report Number 3635

  • Record test pressure and temperature
9. Remarks No Code Data Reports available. Previous NIS-2 Data Report No. 489. Replacement valve desigqned Applicable Manufacturers Data Reports to be attached in accordance with ANSI B31.1 2010E.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White e

Nuclear Enqineer V Date January 03, 20 14 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 15-/1- /

to

/I - V- /3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions rJzý Y1rTA-4V insp(rs Signature National Board, State, Province, and Endorsements Date

_-_,20

/-/

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3636

1. Owner FirstEnerqy Nuclear Ooeratina Company I Date 12/26/2013 (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

Beaver Valley Power Station (BVPS)

Sheet Unit No.

1 of 1

2. Plant P.O. Box 4.

(NAME)

Shippinoport, PA 15077 Order #200440223 (ADDRESS)

3. Work Performed By BVPS Maintenance (NAME)

P.-.

Box 4. ShiDDinaDort. PA 15077 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

NIA Expiration Date N/A (ADDRESS)

4. Identification of System Auxiliary Feedwater (Q2)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case --

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Turbine Ingersoll-Rand T-36555 N/A 1FW-T-2 1972 Corrected No Gland Case Dresser Rand N/A N/A N/A 2007 Removed No Gland Case Dresser Rand N/A N/A N/A 1997 Installed No

7. Description of Work Replaced gland case assembly.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* E]

Nominal Operating Pressure 0 Exempt El Other LI Pressure psi-Test Temp.

_F Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3636

9. Remarks No Code Data ReDorts available. Previous NIS-2 Data ReDort No. 2017. Oriainal manufacture was Applicable Manufacturer's Data Reports to be attached Non-Code. oiDina is ANSI B31.1.

CERTIFICATE OF COMPLIANCE I certify that the statements. made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate Signed of Authorization No.

N/A Thomas White Expiration Date N/A Nuclear Enqineer V Date December 26, 20 13 Thomas White w

.Jl Owner or Owner'sD*ignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 1y--//--

,2-to

/ / /_?, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures, described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

^

I-

  • Commissions JS 7V-4 F 1q,.

d r Y Inspert2ollSignature l

National Board, State, Province, and Endorsements Date

/6G-120 1YQ Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3641

1. Owner FirstEnergy Nuclear Operating Company (NAME) 76 South Main Street - Akron. OH 44308 I Date 01/03/2014 (ADDRESS)

Sheet Unit No.

1 of 1

2. Plant Beaver Valley Power Stl (NAME)

P.O. Box 4. ShiDminaoort. PA 15077 ation (BVPS) 3.

(ADDRESS)

Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippingport, PA 15077 (ADDRESS)

Order #200502825 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case -

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Butterfly Valve Rodney Hunt 2

N/A MOV-1RW-103B 1993 Removed No Butterfly Valve Velan 611014-2 N/A MOV-1RW-103B 2013 Installed No 1-1/4" Stud Trust Manuf.

N/A N/A Trace #KK70 2011 Installed No 1-1/4" Stud Trust Manuf.

N/A N/A Trace #MM99 2012 Installed No 1-1/4" Nut Nova Machine N/A N/A Trace #3J23 2009 Installed No 1-1/4" Nut Trust Manuf.

N/A N/A Trace #KK41 2011 Installed No 1-1/4" Nut Trust Manuf.

N/A N/A Trace #JJ60 2010 Installed No Spacer Plate Energy & Process N/A N/A Ht. #274162 2013 Installed No I

t 24" Pipe Energy & Process N/A N/A Ht. #U42710 2013 Installed No Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3641

7. Description of Work Replaced valve, spacer, studs and nuts. Replaced access window section of 24" pipe.

Weld repaired areas of 24" pipe.

8. Tests Conducted:

Hydrostatic* E]

Pneumatic* ]

Nominal Operating Pressure 0 Exempt [l Other L]

Pressure psi Test Temp.

O F

'Record test pressure and temperature

9. Remarks No Code Data Reports available. Previous NIS-2 Data Report No. 3295. Replacement valve designed Applicable Manufacturer's Data Reports to be attached in accordance with ANSI B31.1 2010E.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear EngineerV Date January 03, 20 14 Owner or Owner's besignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

/_f-__/_d-/

to

// - '1-13

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions&9,'oVrAJ3z P,4 &p' Inspec`ts Signature National Board, State, Province, and Endorsements Date

/-r("

, 20 Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Report Number 3642

1. Owner FirstEnergy Nuclear Operating Company Date 12/26/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippingport, PA 15077 Order #200507885 (ADDRESS)

Repair/Replacement Organization P.O. No., Job No.. etc.

3. Work Performed By BVPS Maintenance Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippingport, PA 15077 Authorization No.

N/A

--(ADDRESS)

Expiration Date N/A

4. Identification of System Main Steam (Q2)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case ----

(b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Check Valve Schutte &

N690563 N/A TV-1MS-1976 Corrected No Koerting 101C Stuffing Box Flowserve WP1448 N/A Trace 2005 Installed No Assy

  1. 05303 Stuffing Box Flowserve WP1449 N/A Trace 2005 Installed No Assy.
  1. 05303 Pipe Plug Energy &

N/A N/A Lot #9428 2006.

Installed No Process

7. Description of Work Replaced stuffing box assemblies and pipe plugs.
8. Tests Conducted:

Hydrostatic* []

Pneumatic* Li Nominal Operating Pressure [

Exempt LI Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Report Number 3642 Other []

Pressure psi Test Temp.

OF

  • Record test pressure and temperature
9. Remarks No Code Data Reports available. I-revibusNIS-2 Data Report No. 2018.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate Signed of Authorization No.

N/A Thomas White Expiration Date N/A Nuclear Engineer V Date January 09, 20 14 Owner or Owner's-Designee, "Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

-//

to

/L/3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied,

.concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

1)AQ

~

y Coclmm is s io ns,/,dAa

/'-'rT~

V,)

YY Inspect5 Signature Y,

National Board, State, Province, and Endorsements Date

/-/d 120 Zy/

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3644

1. Owner FirstEnergy Nuclear Operating Company (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

Date 12/19/2013 Sheet 1

of Unit No.

1 Order #200502816

2. Plant Beaver Valley Power Stz (NAME)

P.O. Box 4, Shippinqport, PA 15077 ation (BVP5R*

tion (BVPS) 3.

(ADDRESS)

Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippingport, PA 15077 (ADDRESS)

Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A

4. Identification of System River Water (M3)
5. (a).Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case --

(b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section Xl Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Ball Valve Anchor/Darling EZ603-1-5 N/A 1RW-145 1995 Corrected No End Piece Flowserve N/A N/A Trace 2011 Installed No

  1. 102360-3 End Piece Flowserve N/A N/A Trace 2011 Installed No
  1. 102361A-1 3" Elbow Energy &

N/A N/A Ht. #LZSR-1 2003 Installed No Process 3" Pipe Energy &

N/A N/A Ht. #812008 2003 Installed No Process

7. Description of Work Replaced valve end pieces, pipe elbow and pipe.
8. Tests Conducted:

Hydrostatic* L]

Pneumatic* E]

Nominal Operating Pressure [

Exempt El Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Report Number 3644 Other []

Pressure psi Test Temp.

__F

'Record test pressure and temperature

9. Remarks No Code Data Reports available. Previous NIS-2 Data Report No. 905.

Applicable Manufacturei's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear EnqineerV Date December 19, 20 13 Owner or Owner's D signee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5-- / / - 1,.-

to

/ / - I-'/- / 3', and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

A -pa Commissions /J9 7

,-3 Y

Inspec*Os Signature National Board, State, Province, and Endorsements Date

/-/U

, 20 Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3645

1. Owner FirstEnerqy Nuclear Operating Company (NAME) 76 South Main Street - Akron, OH 44308 Date 12/20/2013 (ADDRESS)

Beaver Vallev Power Station (BVPS)

Sheet Unit No.

1 of 1

2. Plant P.O. Box 4.

(NAME)

ShiDoinaDort. PA 15077 Work Order #200502817 (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippincjport, PA 15077 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A (ADDRESS)I

( Expiration Date

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case -

(b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section Xl Code Case(s): N/A

6. Identification of Components N/A Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Ball Valve Anchor EZ603-1-10 N/A 1RW-151 1995 Corrected No Darling End Piece Flowserve N/A N/A Trace 2011 Installed No

  1. 102360-1 End Piece Flowserve N/A N/A Trace #2930 2013 Installed No 3" Elbow Energy &

N/A N/A Ht. #LZSR-1 2003 Installed No Process 3" NPS Pipe Energy &

N/A N/A Ht. #812008 2003 Installed No Process

7. Description of Work Replaced valve end pieces, elbow, and pipe nipple.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* El Nominal Operating Pressure 0 Exempt E]

Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3645 Other []

Pressure psi Test Temp.

_F Record test pressure and temperature

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 905.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date NIA Signed Thomas White Nuclear Encqineer V Date December 20, 20 13 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

-- // - / o-to

/ (-

,, 3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

2 Commissions 1,1Vd4~'fi AJ Z9 lnspectoo Signature National Board, State, Province, and Endorsements Date

/-/0-

, 20Qjof Page 2 of 2

FORM NýS-2 OWNER'S REPORT FOR REPAIIRS/REPLACEMENT ACTIViTY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3646

1. Owner FirstEnerqy Nuclear Operating Company Date 12/04/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

S).nit NIL).

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippincqport, PA 15077 Work Order #200504125 (ADDRESS)

RepairlReplacement Organization P.O. No., Job No., etc.

3. Work Performed By BVPS Construction Services Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippingport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System River Water (03)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S71 Addenda, Code Case..

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section Xi Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Ball Valve Anchor E2635-1-2 N/A 1RW-156 1995 Corrected No Darling End Piece Flowserve N/A N/A

-Trace #2830f 2013 Installed No End Piece Flowserve N/A N/A Trace #2930 2013 Installed No 3" NPS Pipe Energy &

N/A N/A Ht. #812008 2003 Installed No Process

7. Description of Work Replaced valve end pieces and pipe nipples.
8. Tests Conducted:

Hydrostatic* []

Pneumatic* E]

Nominal Operating Pressure [

Exempt L

-)ther.F1l Pre-.,Ure.i Test Temo. _..

r L

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3646

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 906.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed Thomas White Expiration Date N/A Nuclear EngineerV Date December06, 20 13 Owner or Owner's D'esignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

-- //-/

to

/ / - V-/,JP, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_2 Commissions

,f -/*"/Na A,

,L3 W'"

Inspectps Signature National Board, State, Province, and Endorsements

___] Dat' Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 00 Reoort Number 3651

1. Owner FirstEnergy Nuclear Generation, LLC Date 07/25/2013 (NAME) 76 South Main Street - Akron. OH 44308 (ADDRESS)

Sheet Unit No.

1 of 2

1

2. Plant Beaver Vallev Power Station (BVPS1 (NAME)

Shippingport, PA 15077 (ADDRESS)

3. Work Performed By BVPS - Maintenance (NAME)

Shiooincwort, PA 15077 WO# 200562915 Repair/Replacement Organization P.O. No.. Job No.. etc.

Type Code Symbol Stamp Authorization No.

Expiration Date N/A N/A (ADDRESS)

N/A

4. Identification of System River Water (Class 3)
5. (a) Applicable Construction Code ASME VIii 19 68 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section XI Code Case(s): N/A
6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Heat Henry Vogt 18650 11793 1CC-E-11B 1971 Corrected Yes Exchanger Machine Co.

Plug Joseph Oats N/A N/A N/A 2002 Installed No

7. Description of Work Plug tubes.
8. Tests Conducted:

Hydrostatic* El Pneumatic* ED Nominal Operating Pressure Z Exempt [

Other F]

Pressure psi Test Temp.

O F tRecord lest pressure and t*mperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 00 Report Number 3651

9. Remarks Code Data Report Attached, No previous NIS-2 Reports. Plug PO# 7066912 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed J1 Sciuilli Nuclear Engineer III Date July 2 5 th, 20 13 Owner or/wner's Desfne-e, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5--- //-/"I-to 2 /-2

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.,

Commissions J<

f!* T 4 J

-,J-"

?,-. y National Board, State, Province, and Endorsements Date 30~

20 /

Page 2 of 2

~tr*1 1 w-

-1 c

.I U.. :.. 11::

i :",."

\\ -. r.I i,,. d, I I, Ii,. I-r,,, i" i,

2

....- i i'

Thti.. 2.;

III,

.]* !>-. "

  • - :--..L
t.

[---

-.:iit-i..

o

t.

N,.;.

t

o.

d J !. N t

.I t -

I;'."

.R*:

5

, n'.:

I......

y.

"1 I

J.. O- -U. r:jj:

L c...irf.

r in t

8

-in.

7. e.p*<..ho -- ".

,.k, -".__

ot',

< l,.u 7.Op_.i '..

... -_._ Anci.

N.

.a r- (C-, e i t, I. "e ci" 1

( 1 T

.L.-S C.

WeLded)

(.I-rio

.u e i; S; JACET\\-: !,;

CL S R

."L...

+.*-'

s Le Ii.T, h.....cv'_

re, i sinne I.-

'ild, Usc.H, m -v O__etc __)

G 1!

7.

I Adn cony lahe r.j~

c~

t-

.1 14

.1 ri.

a.flow..

"D> abl, wo,;*rkin t._.

pros

.I W

psi... a... max.:

rcmn.

{bM '-..

lss, mo 0 )

ZL Pr.S s 1 1c a tCo C r..*20 t E E l:1, E

1i0 c. p i iI l u Hr e

i5t-cL1n F i-t 1Q,

R.:.iu 1*

,tlc T

R-,

rin Ap,.Ec A

nrtIEl Ha j

-n.,-

t,,

tr..,-h-'

e A..

E8. JA CKETIC,:

RIvI ra

"__TALS:I h

lo

'n 1'*

Pitch Di a

s.

JAcE CLO E7 Et-mD2-S int.

crI[

cti y+/-nh-- at ack Ie

'j7.T-7**7-c'.s's c-i t

eeN IdiIUINs n,

i2 r

-ica

.N

.*trb,

rse
9. (t-:nst-ucsed f',or max.

-- Fez;[

tn iwh c

E u(,

r, I

.T It fIe r s l0 an d II to h e cc -,,

-'tc-d fo r tu b. s,-ci Ne n

IL0. TSl

<ll f T : cr-ii ",ra m*. \\Dindl

  • .. % "")in zz-i

-.'v -'-- -

Girh.......

E-(1........i...n i_.of ruoc="

Floa.

(t in

.Eaterial

__N Diam.

_In.

E lFhicR-lncss Ein.

_'h

__en_

7*.

RýnF 571 c Location

. *. Thc-iee Rais.ais.ao...'

5'

,-i"...Cg, e.N n Ul. TI:

IS

'i;.'-:a

}

3~ *." :

-*l+

In-. "I}Jickrtes' z

r<;

g, m

e

~*

-=..-_=*

.,-:_t (b)ChanelCcv rL :i,{4T 7.*---:

s *,::

r fmý I

inm a.lc,,.

comt, iad f-o.cssc,."

or ch.),,n-ls of h'.'a c4-c 3i

-g.

ý.e..

Sn:

ati:i.,:

.N 7.

%ýý r" ia i.

,hicr

!it.

-.MiBnc

'In Diam

!n r,

i r.

c.

[

p-.,

'A..... T..

" W ~.*

.f"7,.

--i=......

r A tth S o -i, Ct2 r2 atitl s

1 r 4-'

L.io

,p t*:"C*

  • ce

'.p ;

.i't rl'.

r I I 5

-'F.A te fo Sx Lo, c

L-slion I:

ff:.

r i,

c I Girth

't"- :!*

c4 z* olT

__ 'ri:2U

ý1""

q

n-'d "7 ;

N.of co~urstes

\\1-7

"..".j' 14,. HEAIDS (a) \\lat...ria" t".-.

t b'l it' l-':, -2 S.

a LL.. i

".I aroNn Kntu

.ckle Ell-tiici H

he t!

Si.re ti Pr'--

Location Th I,. kickne, s-s R(ad-s R ad i u is tio x.ntc

.r or r

) Toe, a

(b) Chann el 4,:-':,?

t 14L'*'_.,Z-=::g*

t/

./.)'

  • 1...;

(c) Floating If.'-

re ov hie bot'Iýd

. %r 0,

h fit nQ

15.

Coi ric c

for

-riax.

r' "e

s'.I t**-

all1 11;1v,

'A LI, k*,,inL! p~ce-s.**

.. ::2e.'

I X ma rD.i L'nI "F.

l'*s th

-- 2i

)i-

.*+.

=.,!.)

Pre',s

.L psi.

Item,; b,..h w [I) i.e c",mw l.-,d

[.:a lts-s"v,.r

.1Ul:t"

16. S A F : TY ýA 1. VE OlTr1. U1: S:

m.-,,mb r

S: /.Q

!_oc,';tio:;!

17. NOZZLES O'

!.1~t'. Dra rt

~

l'd-e Di~m. vrSize cpM

,e h c n.*

.~e i,

l.v;2 Y

L-_

FORM "J

U-I (baick) lN.';ll'lt: l'O, ii.:,tqj.c

.Nc.

Si ze Lo,_ation Il N iN(,,:

ilan..il-..,,".......

Size Location "lThr c'tri':l,. \\:-t Size I.ocatrion

19. S1 I'M ' RQ IS: Skirt cugr I uL

's gs Leg,;

O0hrh r NN".'

-rt i

mub-he.rer)

,.Describe) w, '--T 14

20. RLMA

.- uK>:. ____.:.2. :'t..;'

L cf:-..

.,C-..:-

,F....*

.Ž..

. 2 _______________________

O.2...

'-i-r...

t _.

I

"=*-,'*.*

!-".'-"Ž i.,::

i ;:.

V

.. *:?..... ';.t-.Ž-t C12:

'dit<.S-"":

a.._iU1OXC 5.

(L.ric-" de sc 'rt;i tot-. '..f

.ur-p :}s,,f the

'e s.%,, as Air Tank,

  • After Cooler, Jacketed Cooker. etc. State contents of each part.)

Ae cerdify chat the statemntes matt in this report are correct and that all details of design, material, construction, and

,orkmanship of this vessel conform to the ASII" C'ode for Ur:fired Pressure Vessels.

"19 -

ionel

" i t

X it t

By.

Certificate of Auth r triza o En pires 01..'

-: L:k.3i.

_.I,I *- j *.-c....

CiIfIH FICATVI O" SHOP I 'SIP2CTI ON VESSEL MADE BY r-t-

at I, the undersigned, holrdn, a ;lid contissir.-n isssed hy the National Board fi Boiler and Pr-+/-soure Vessel Inspectors and/or the State or Province.. -and employed by 1'

'.,5 _...

t2

)'A X..*.-r J

r' have inspected the pressure vessel described in fits manufacturers data report an r:.

19'-

" and state that to the best of m y kno 'tedA e and belief, the mranufac-hurer has constrected th se in accordahce -wi th the applicable sections of the ASME D-oter cad Pressure Vessel Code.

By sig*ting this cert'ica--"

tneih-r -the Inspector nor his employer makes arty warranty,, expressed o.

im"lplied, concerning the preosure

.ease; i es.rited :rc this manufacturer's data report. Furthermore, neiither the Inspector nor his eopic- 'er shall be liable in any marinenr

.;l any p.ersenal i*l;i',-

or property damage or a loss of any kind arising from or connncted with this inspection.

Date"'"t to":;.....:

" -f'"

Commissions FtT'T.:..lz Sta'Ae"-o No (C.i-i.Ii-I:I.VliT Hi-1"1ELI.I) A-SSI::\\lHIA*

I.PI-(I'TIO\\

1, the undera;tiged. holding a valid conv.':s,:.on issuel by" :he National Board of Boilhr and Pressure Vessel Inspectors and/or the State or a~ov in-.-

nd sntployed by.

of ha;vz, zorpart.',.

the statements in this 'manuf~acturer's data recort with the "es.::il.sd pre s::et' "c:;vlt and state that pa -rt:: r eerred _a as t.!a it',s_

not incluted :r. the c ertý h:t *.te

.-;.p inspectiun tavco be--n inspected b:. me and that to the best of my knowledge and h-t!inf the manr.af-c:ur-.r ::i:; cor'st:.c.- " ore asse:bie.d th us pressure versei i n. acc.,r'ance w tth the applicahle sections of the AS.M E S-tiler and Prestte Vcss.el (od.-.

The dn:sertbed vensel -as inspectea and subjected to a hydcostatic test of psa.

B;. :gotn i', :.his c--rti r-.

Fi l" rn-;ectc ro.r "hi.;

,'np'c)--r ae.

any

" rr-nt,, e:X.,eZsed or implied. ccncen'ing thre press.ure "...;.

I

...*.-rr z

":: :t.:l:

r,r !..irr:r's.!&.; rr' i. F"urri:er;r c', ne iher thie !.spector nor his e s-er shAll be :iarte

n z :rr.r:
r. i r.- r

.r r y r."

F -

ir

.r r ; " *.r,*r,>p'r r

l'ri r -."

r t a s tb a n icn" d r sr

-i g f r o m o r c o n n e c t e d w i t h t h i s t n s p LE.ti r '.

fate ___ __-......

1 I'Fillm-,

in i.i.S

If'-;>,

iitt-: -. i

r. i!-.
r;-::.

-,,: :,t'on ti, Aj li:.,-

i.

i:rn St..%-,s'-v York, N.). 16o:-

FOR MPS-2 OWNER'S REPORT FOR REPAMRSIREPLACEMENT ACTDVfTY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Repbor Number 3658

1. Owner FirstEnergy Nuclear Operating Company (NAME) 76 South Main Street - Akron, OH 44308 I Date 12/05/2013 (ADDRESS)

Reaver Va!lev Power Station (RVPS'i Sheet 1

of 1

  • -Uni.No.--------- Ordr #2-0-----

Work Qrder #200406970

2. Plant P.O. Box 4, V a re.

Sta io (NAME)

Shippingport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Maintenance (NAME)

P.O. Box 4. Ship)pinaDort, PA 15077 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A (ADDRESS)

4. Identification of System Feedwater (Q2)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case ---

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Check Valve Schutte &

N-700484 N/A 1FW-156A 1976 Corrected No Koerting 1-1/2" Stud Nova Machine N/A N/A Trace #257C 2006 Installed No 1-1/2" Nuts Nova Machine N/A N/A Trace #4T67 2010 Installed No 1-1/2" Helicoil Nova Machine N/A N/A Lot 2013 Installed No

  1. 50412345
7. Description of Work Replaced studs & nuts and installed four helicoil inserts.
8. Tests Conducted:

Hydrostatic* LI Pneumatic* LI Nominal Operating Pressure LI Exempt Z ffOther f Pressure

-r.!

.Tet Temn.

-Record test pressure and temperature Page 1 of 2

FORM NIS-2, OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 ReV'. 01 Report Number 3658

9. Remarks No Code Data Report available.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed Thomas White Owner or Owner's Designee, Title Expiration Date N/A Nuclear EnqineerV Date December 05, 20 13 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5 /l-

/Q?..

to 11 -

- 13, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

/ 1J 2,ý J

commissionsC Inspec)ts Signature National Board, State, Province, and Endorsements

- DDate 20 /2 Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of theASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3659

1. Owner FirstEnerqy Nuclear Operatinq Company Date. 12/23/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippinqport, PA 15077 Order #200486539 (ADDRESS)

Repair/Replacement Organization P.O. No., Job No., etc.

3. Work Performed By BVPS Maintenance Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippinqport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Main Steam (Q2)
5. (a) Applicable Construction Code ANSI 831.1 1967 Edition, S'71 Addenda, Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section Xl Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Valve Dresser-Rand N/A N/A 1MS-464 1976 Removed No (Terry Steam Turbine)

Valve Dresser Rand HY28603/T-N/A 1 MS-464 2002 Installed No 87069D

7. Description of Work Replaced valve with spare.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* E]

Nominal Operating Pressure [

Exempt El Other E]

Pressure psi Test Temp.

F___

F Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Report Number 3659

'Record lest pressure and temperature

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 2016. Heat No. of replacement valve Applicable Manufacturer's Data Reports to be attached is 216302 / E6442-5.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

Signed Thomas White

  • Expiration Date N/A Date December 23, 20 13 e, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

..*- 1/I-

/ --

to

/1/-

/-/-?

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

)~i Commissions &*ydyTz 4d/Z4

/--Zf y'A d-3 YFi/

National Board, State, Province, and Endorsements Ins por's Signature Date

/-_(I -

,20 /LK.

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3667

1. Owner FirstEnergy Nuclear Operating Company Date 12/16/2013 (NAME) 76 South Main Street - Akron, OH 44308 Sheet 1

of 1

(ADDRESS)

Unit No.

1

2. Plant Beaver Valley-Power Station (BVPS)

(NAME)

" P.O. Box 4, Shippingport, PA 15077 Order #200546744 (ADDRESS)

Repair/Replacement Organization P.O. No., Job No., etc-

3. Work Performed By BVPS Construction Services Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippingport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Riverwater (Q3)

A(*)

,pplicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case ---

(b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Piping Stone &

N/A N/A WR-20 1976 Corrected No Webster 24" Pipe Energy &

N/A N/A Ht. #U42710 2013 Installed No Process

7. Description of Work Replaced area of pipe cut-out for access as well as degraded area of pipe.
8. Tests Conducted:

Hydrostatic* L]

Pneumatic* F1 Nominal Operating Pressure E Exempt EI Other F]

Pressure psi Test Temp.

° F

'Record lest pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY.

As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3667

9. Remarks No Code Data Reports available. Previous NIS-2 Data Report No. 3135.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate Signed of Authorization No.

N/A Thomas White

/'

Expiration Date N/A Nuclear Engineer V Date December 16, 20 13 ThomasWhite Owner or 0wnerr-Designee, Ytle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period I-d/f-/,,- to

//-/-/.

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions 19,,-C-4p Yu

!nsotor's Signature National Board, State, Province, and Endorsements Date 1 20

/-3 Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 ReDort Number 3668

1. Owner FirstEnergy Nuclear Operating Company (NAME) 76 South Main Street - Akron. OH 44308 I Date 12/04/2013 (ADDRESS)

Sheet Unit No.

1 of 1

2. Plant Beaver Valley Power Stz (NAME)

P.O. Box 4. ShiDoinaDort. PA 15077 ation (BVPSI (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippinoport, PA 15077 Work Order #200564451 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A 4.

5.

6.

(ADDRESS)

Expiration Date N/A Identification of System Safety Iniection (Q2)

(a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case -

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c) Applicable Section XI Code Case(s): N/A Identification of Components Corrected, National

Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Piping Stone &

N/A N/A SI-163 1976 Corrected No Webster 3" Pipe Energy &

N/A N/A Ht. 40904 2008 Installed No Process 3" Blind Energy &

N/A N/A Lot #5774 2003 Installed No Flange Process 5/8" Stud Nova Machine N/A N/A Trace #0B13 2013 Installed No 5/8" Stud Nova Machine N/A N/A Trace #8M79 2013 Installed No 5/8" Nut Nova Machine N/A N/A Trace #8T34 2013 Installed No 6"x3" Pipe Tioga Pipe N/A N/A Trace

.2013 Installed No Reducer

  1. NJSZ-1 Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Report Number 3668 3" Flange Tioga Pipe N/A N/A Ht. #248301 2013 Installed No

7. Description of Work Installed new pipe, fitting, flanges, studs & nuts into system.
8. Tests Conducted:

Hydrostatic* [

Pneumatic* []

Nominal Operating Pressure N Exempt [

Other F1 PreSsure psL TJeist_

oF Record test pressure and temperature

9. Remarks No Code Data Report available.

Applicable Manufacturerjs Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date December 20, 20 13 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5"- /

- /

  • to

/ /- 4/-/3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

eu Commissions

/,2,*/,.,

/d%

IV (

Inspe or's Signature National Board, State, Province, and Endorsements Date

/-2/

,20J Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number, 3669 2.

2.

Owner FirstEnerqy Nuclear Operating Company (NAME) 76 South Main Street - Akron. OH 44308 I Date 12/16/2013 (ADDRESS)

Beaver Valley Power Station (BVPS)

Sheet Unit No.

1 of 1

Plant Prn BRx 4 (NAME)

Shinninanort, PA 15077 Order #200564397 (ADDRESS).

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4. Shiprinaoort, PA 15077 Repair/Replacemeni Orgarnzation P.O. No.. Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A

4. Identification of System Auxiliary Feedwater (M3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case -

(b)

Applicable Edition of Section XI Utilized. for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Piping Stone &

N/A N/A WAPD-3 1976 Corrected No Webster 3" Blind Energy &

N/A N/A Ht. Code 2013 Installed No Flange Process WEY 4"x4"x3" Tee Energy &

N/A N/A Ht. Code 2013 Installed No Process X322V-1 3" Flange Energy &

N/A N/A Ht.

2006 Installed No Process

  1. 2016ANF4 3/4" Stud Nova Machine N/A N/A Trace #8H76 2013 Installed No 3/4" Nut Nova Machine N/A N/A Trace #0C17 2013 Installed No
7. Description of Work Installed reducing tee, flanges, studs & nuts into existing piping system.

Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3669

8. Tests Conducted:

Hydrostatic* []

Pneumatic:* E]

Nominal Operating Pressure 0 Exempt L]

Other E]

Pressure psi Test Temp.

° F tRecord est pressure and temperature

9. Remarks No Code Data Reports available.

Applicable Manufacturer's Data Reports to be attach-d CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date December 16, 20 13 Owner or Owner's signee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

/,- -/,)-

to

/(- V-/3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions, f/"-'r4' oL.*,s/

Inspect,6.As Signature National Board, State, Province, and Endorsements Date

___-_,20

/

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3670

1. Owner FirstEnergy Nuclear Operating Company (NAME) 76 South Main Street - Akron, OH 44308 I Date 12/16/2013 (ADDRESS)

Beaver Valley Power Station (BVPS)

Sheet 1

of I

Unit No.

1 Order #200564457

2. Plant P.O. Box 4, (NAME)

Shippinaoort, PA 15077 (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4. Shiooinonort_ PA 15077 Repair/Replacement Organization P.O. No., Job No., etc-Type Code Symbol Stamp N/A Authorization No.

N/A 4.

5.

6.

(ADDRESS)

Expiration Date N/A Identification of System Riverwater (Q3)

(a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case --

(b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A Identification of Components Corrected, National

Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Piping Stone &

N/A N/A WR-8 1976 Corrected No Webster 8" Pipe Energy &

N/A N/A Ht. #X05072 2011 Installed No Process 8" Weldolet Energy &

N/A N/A Ht. Code 2013 Installed No Process 6498ANF 8" Flange Energy &

N/A N/A Ht. #237P505 2013 Installed No Process 8" Blind Energy &

N/A N/A Ht. #217L812 2013 Installed No Flange Process Y"

Stud Nova Machine N/A N/A Trace #8D44 2013 Installed No 3/4" Nut Nova Machine N/A N/A Trace #7U65 2012 Installed No

7. Description of Work Installed weldolet, pipe,, flanges, studs & nuts into existing piping system.

Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASMVE Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3670

8. Tests Conducted:

Hydrostatic* E]

Pneumatic* LI Nominal Operating Pressure 0 Exempt El Other E]

Pressure psi Test Temp.

OF

'Record test pressure and temperature

9. Remarks No Code Data Reports available. Previous NIS-2 Data Report No. 411.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date December 16, 20 13 Owner or Owner's De 'gnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period J-I/'(- /,)-

to

/,-

V- /-

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

~___~_

Commissions,JJ' ýLc/,;

4-_

lnsp rs Signature National Board, State, Province, and Endorsements Date i.-/'-

, 20 /3 Page 2 of 2

FORM NHS-2 OWNER'S REPORT FOR REPAMRS/REPLACEMENT ACTGDVTY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01

1. Owner FirstEnerqy Nuclear Operating Company (NAME) 76 South Main Street - Akron. OH 44308 Report Number 3673 Date 12/05/2013 (ADDRESS)

Sheet 1

of 1

Unit No.

!1 Work Order #200501635 Repair/Replacement Organization P.O. No., Job No., etc.

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4, Shippingport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippinwport, PA 15077 Type Code Symbol Stamp Authorization No.

Expiration Date N/A N/A (ADDRESS)

N/A

4. Identification of System Containment Electrical Penetration (Class 2)
5. (a) Applicable Constrttction Code Non-Code

--- Edition, -- Addenda, Code Case ---

(b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section Xl Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Electrical Viking N/A N/A 1RCP-3F 1976 Removed No Penetration Industries Electrical QualTech NP 047 N/A 1RCP-3F 2013 Installed No Penetration

7. Description of Work Replaced electrical penetration.
8. Tests Conducted:

Hydrostatic* D Pneumatic* Z Nominal Operating Pressure []

Exempt E]

.r,,,

F--

Pssure 45.01 nsi Test Tmr, Arab

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3673

9. Remarks No Code Data Report available. Original electrical penetration was developed using ASME Section III Applicable Manufacturer's Data Reports to be attached Class 2, 1971 Edition as a guide per Specification BVS-384 but not Code Stamped. The replacement electrical penetration was designed, built and tested to ASME Section III, Class MC, 1971 Edition, but also was not Code Stamped per Specification 8700-DES-0534. A Containment Type B test was performed on the installed replacement electrical penetration.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date December 05, 20 13 Owner or Owner's De'signee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period -/(-L/,,.

to

/(-

q-

/-

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

/i*

-" -/"

  • Commissions d

/-,4 ;-d" 3

5Z InsXctor's Signature National Board, State, Province, and Endorsements Date

/

/2-

, 20 /13 Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3676

1. Owner FirstEnercy Nuclear Generation GQ-i.

I Date 10/22/2013 (NAME)

Wf241t 76 South Main Street - Akron, OH 44308 (ADDRESS)

Beaver Valley Power Station (BVPS)

Sheet 1

of Unit No.

1

2. Plant P.O. Box 4.

(NAME)

Shippingport, PA 15077 Work Order #200508061 (ADDRESS)

3. Work Performed By BVPS - Maintenance (NAME)

P,O. Box 4. ShioDinaoort. PA 15077 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date (ADDRESS)

4. Identification of System Residual Heat Removal (C)
5. (a) Applicable Construction Code ASME Section III 1968 Edition, ---Addenda, Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section Xl Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Heat Joseph Oat, 1832-1..

368 1RH-E-1A 1969 Corrected Yes Exchanger Co.

1-3/8" Stud Nova Machine N/A N/A Heat #2U86 2009 Installed No 1-3/8" Nuts Nova Machine N/A N/A Heat #5Y52 2011 Installed No

7. Description of Work Replaced one flanqe stud and two nuts.
8. Tests Conducted:

Hydrostatic* F]

Pneumatic* E]

Nominal Operating Pressure E]

Exempt M Other Li Pressure psi Test Temp.

°_F

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Report Number 3676

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No. 3293.

Applicable Manutacure"s Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Staff Enqineer Date October 22, 20 13 Owner or Owner's Design e, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

.3---f-

/,1L to Jo-, 2._-

2-

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

lns~rs CommissionsJ' Y,-,Ji*

/AJ, Y. (

Inspýo0s Signature National Board, State, Province, and Endorsements Date d_______--_,

20 1/3 Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3677

1. Owner FirstEnerqv Nuclear Operatinci Company Date 12/13/2013 (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

Beaver Vallev Power Station (BVPS)

Sheet Unit No.

1 of 11 1

2. Plant (NAME)

P.O. Box 4. ShiDDinooort. PA 15077 Order #200501227 3.

4.

5.

6.

(ADDRESS)

Repair/Replacement Organization P.O. No.. Job No., etc.

Work Performed By BVPS Construction Services Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippinqport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date.-

N/A Identification of System Chemical and Volume Control (Q1)

(a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case --

(b)

Applicable Edition of Section XI Utilized for RepairiReplacement Activity 2001E-2003A (c)

Applicable Section XI Code Case(s): N/A Identification of Components Corrected, National

Removed, ASME Name of Name of Manufacturer Board

.Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Pipe Support FirstEnergy N/A N/A PS-6 2013 Installed No Angle Energy &

N/A N/A Ht. #1023563 2013 Installed No Process U-Bolt Anvil Intl.

N/A N/A N/A 2010 Installed No Angle Energy &

N/A N/A Ht. #JJ2878 2013 Installed No Process Plate Energy &

N/A N/A Ht.

2009 Installed No Process

  1. B8S7299 Anchor Bolt Hiltj Inc.

N/A N/A N/A 2013 Installed No

7. Description of Work Fabricated and installed new pipe support on pipeline CH-140.

Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3677

8. Tests Conducted:

Hydrostatic* ]

Pneumatic* El Nominal Operating Pressure [E Exempt Z Other i-Pressure psi Test Temp.

"F

'Record test pressure and temperature

9. Remarks No Code Data Reports available.

Applicable Manufacturer's Data Reportr,-to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A.

Expiration Date N/A Signed Thomas White Nuclear Engineer V Date December 13, 20 13 Owner or Owner sDsignee, Tltle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

.'-.//'/,/L to

/

1-

.2

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

LLJ?

2 Commissions 1J-,R,99--*,9z--,".Z A.1,"_.3 YY Inspecto/s Signature National Board, State, Province, and Endorsements Date

,20

/0 Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Report Number 3678

1. Owner FirstEnerqy Nuclear Operating Company (NAME)

I Date 12/06/2013 76 South Main Street - Akron. OH 44308 (ADDRESS)

Sheet Unit No.

1 of 2

1

2. Plant Beaver Valley Power StE (NAME)

P.O. Box 4. ShiDDinaoort. PA 15077 ation (BVPS)

Order Nos. 200579267. 55117956 (ADDRESS)

3. Work Performed By BVPS Valve Team (NAME)

P.O. Box 4, Shippinqport, PA 15077 Repair/Replacement Organization P.O. No-, Job No., etc.

Type Code Symbol Stamp N/A (ADDRESS)

Authorization No.

Expiration Date N/A N/A

4. Identification of System Main Steam (Q2)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 2001E-2003A (c) Applicable Section XI Code Case(s): NA

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Nozzle Enertech 11075 N/A 1 MS-1 9 2004 Corrected Yes Check Valve Disc Enertech 37898 N/A Ht. #LDH 2005 Removed Yes Disc Enertech 56381 N/A Ht. #LDH 2013 Installed Yes 3/4" Stud Trust Manuf.

N/A N/A Trace #SS97 2013 Installed No

7. Description of Work Enertech replaced the valve disc and weld restored corrosion resistant overlay on body.

Valve Team removed, reinstalled valve and replaced the inlet/outlet flange studs.

8. Tests Conducted:

Hydrostatic* E]

Pneumatic* E]

Nominal Operating Pressure E]

Exempt Z Other E]

Pressure psi Test Temp.

O F Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSiREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3678

9. Remarks Code Data Report attached. Previous NIS-2 Data Report No. 3337.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear EngineerV Date December 20, 2013 Owner or Owner"s besignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

/1-

/ d to

// -

V - /3

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

~Signature Commissions,14 YV/Q A W17_

Av,,23 *"

Inspectl Signature National Board, State, Province, and Endorsements Date (3-

,20

/V9' Page 2 of 2

FORM N-2 CERTIFICATE HOLDER'S DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. 1 of 2

Enertech - A Business Unit of Curtiss-Wright Flow Control Co.; 2950 Birch St.; Brea, CA 92821

1. Manufactured and certified by
2. Manufactured for
3. Location of instfllation (name and address of Npr Certificate Holder)

First Energy Corp.; P.O. Box 6100; Johnstown, PA 15907-6100 (name and address of purchaser)

Beaver Valley Nuclear Power Plant; Route 168; Shippingport, PA 15077-(name and address)

4. Type PC96339 Rev. D SA564 TP630 H1100 140 KSI N/A 2013 (drawing no.)

(material spec. no.)

(tensile atrength)

(CRN)

(year built)

5. ASME Code,Section III, Division 1 1971 Summer 1972 3

None (edition)

[Addenda (if applicable) (dale))

(Class)

(Code Case no.)

6. Fabricated in accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Date N/A (no.)

7. Remarks Qty. 1, Disc, 3" DRV-Z, P/N: PD98401-2, ENERTECH Project No.: 390169. Due to size & configuration, Disc is identified with Disc Item. No. (D111 8N), material heat code (LDH) and Disc serial number (56381).
8. Nom. thickness 0.394" Min. design thickness 0.115" Diameter+_

2.717" OD Length overall 3.386"

9. When applicable, Certificate Holder's Data Reports are attached for each item of this report.

National Part or Appurtenance Board No.

Serial Number in Numerical Order ii) 56381 N/A (2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

(12).. _

(13)

(14)

(15)

(16)

(17)

(18)

(19)

(20).

(21)

(22)

(23)

(24)

(25)

National Part or Appurtenance Board No.

Serial Number in Numerical Order (26)

(27)

(28)

(29)

(30)

(31)

(32)

(33)

(34)

(35)

(36)

(37)

(3O)

(39)

(40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

(5D)

10. Design pressure 1100 PSIG Temperature 560OF Hydro. test pressure N/A at temp. N/A (when applicable) a Supplemental information in the formof lists, sketches, or drawings may be used provided: (1) size is 81/2 X 11; (2) information in items 2 and 3 on this Data Report is included on each sheet; and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(07/10)

FORM N-2 (Back-Pg. 2 of 2

)-

Certificate Hoider's Serial Nos.

  • 56381 through N/A CERTIFICATION OF DESIGN Design specifications certified by Francis W. Gardner RE. State PA Reg. no.

036614-E Design report* certified by Ira J

p.

Spiverman RE. State CA Reg. no.

23 CERTIFICATE OF COMPLANCE We certify that the statements made in this report are correct and that this (these)

P/N: PD98401-2, Disc conforms to the rules of construction of the ASME Code,Section III, Division 1.

NPT Certificate of Authorization No.

N-2827 Expires QrOobet 11, 2014 Date 3'

T

  • Name A Business Unit of Curtiss.Wright Flow Control Co.

Signed

.(NFTcrbficate Holder) tauthorid representa'iva)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province.

Of Califrmia HSB--CT of ___________and employed by of Conn eCticut i

-f Connec*icut have inspected these items described in this Data Report on

!' Z5

, and state that to the best of my knowledge and belief, the Certificate Holderhas fabricated these parts or appurtenances in accordance with the ASME Code, Section IIlI Division 1. Each pait listed has been authorized for stamping on the date shown above.

By signing this certificate neither the inspector nor his employer makes 'any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither theinspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected wth "his inspection.

_.__Ahri__r-itlo45ia -

2n Zst.9 Date

'b-Signed

-Commissions Authonizad Nudear inpe~

[ National Bd. find. endorsernintsl. and state or pray, and no.)

(09/06)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Report Number 3679

1. Owner FirstEnerqy Nuclear OperatinQ Company Date 10/30/2013 (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

Sheet 1

of Unit No.

1

2. Plant Beaver Valley Power St*

(NAME)

P.O. Box 4, Shippinaoort. PA 15"077 ation (BVPS)

Work Order #200376149 3.

4.

5.

6.

(ADDRESS)

RepairlReplacement Organization P.O. No., Job No., etc.

Work Performed By BV Valve Team Type Code Symbol Stamp N/A (NAME)

P.O. Box 4, Shippinqport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A Identification of System Chemical and.Volume Control (Q1)

(a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case ---

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section XI Code Case(s): N/A Identification of Components Corrected, National

Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Globe Valve Masoneilan H-60941-1-4 N/A LCV-1CH-1976 Corrected No 460A Plug Enertech N/A N/A Ht. #78118-3 2010 Installed No 7/8" Nut Nova Machine N/A N/A Ht. #7C40 2012 Installed No 7/8" Stud Trust Manuf.

N/A N/A Ht. #M41110 2012 Installed No

7. Description of Work Rep!..ap

,_bedV/bonnet studs and nuts.

8. Tests Conducted:

Hydrostatic* LI Pneumatic* E]

Nominal Operating Pressure []

Exempt M Other L1 Pressure psi Test Temp.

o F

'Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3679

9. Remarks No Code Data Report available.

Applicable Manutaclurer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed Thomas White Expiration Date N/A Nuclear Enqineer V Date October 30, 20 13 Owner or Owner*'sDesignee, 'Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

/) /(- / o to

/ 0 -3 / -(ý2

, and state that to the best of my knowledge and belief, the Owner.has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

~~,, /

Commissions ee

~~7~t~'

/,

l~?

Inspes Signature F

w National Board, State, Province, and Endorsements Dlate 1

-1 20 1,3 Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3681

1. Owner FirstEnerqv Nuclear Operatinq Company I Date 12/13/2013 (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

Sheet Unit No.

1 of 1

2. Plant Beaver Valley Power Station (BVPS)

(NAME)

P.O. Box 4. ShiooinaDort. PA 15077 Order #200578712 (ADDRESS)

Repair/Replacement Organization P 0. No. Job No.. etc.

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4, Shippinqport, PA 15077 Type Code Symbol Stamp Authorization No.

Expiration Date N/A N/A (ADDRESS)

N/A

4. Identification of System Reactor Containment (02)
5. (a) Applicable Construction Code ASME Section III & VI1) 1968 Edition, -- Addenda, Code Case ---

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 200IE-2003A (c)

Applicable Section Xl Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Containment Graver Tank N/A N/A 1-RCBX 1976 Corrected No Liner Plate Energy &

N/A N/A Ht.

2010 Installed No Process

  1. WOB525
7. Description of Work Cut out and replaced a section of the liner plate.
8. Tests Conducted:

Hydrostatic* El Pneumatic* Z Nominal Operating Pressure El Exempt [3 Other [F Pressure 45 psi Test Temp. Ambient °F Record test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703:02 Rev. 01 Report Number 3681

9. Remarks No Code Data Reports available. Previous NIS-2 Data Report No. 3152. Original containment liner Applicable Manufaclurer's Dala Reports to be atlached used ASME Sections III and VIII as guidelines for construction and the liner was not stamped.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate Signed of Authorization No.

N/A Thomas White y

Expiration Date N/A Nuclear Engineer V Date December 13, 20 13 Owner or Owner's dE'sig-nee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

-.-5-/

/- /,-

to

/,/- Y/-/?S

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Ins, ctor's Signature Commissions 1-'/ Q

,,9,'--f National Board, State, Province, and Endorsements Date

/2.

- /2-120~

Page 2 of 2

FORM NIS-2'OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rvi1" Report Number 3682

1. Owner FirstEnery Nuclear Operatinci Company I Date 10/30/2013 (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

.Sheet Unit No.

1 of 1

2. Plant Beaver Valley Power St (NAME)

P.O. Box 4. Shirpinooort. PA 15077 ation (BVPS)

Work Order #200578610 (ADDRESS)

3. Work Performed By BV Valve Team (NAME)

PO. Box 4. Shinninanort PA 15077 Repair/Replacement Organization P.O. No.. Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A (ADDRESS)

4. Identification of System Residual Heat Removal (02)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case--

(b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 2001E-2003A (c)

Applicable Section X1 Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Gate Valve Anchor N/A 1RH-2 1976 Corrected No Darling 1-1/8" Stud Trust Manuf.

N/A N/A Ht. #SS15 2012 Installed No 1-1/8" Nut Nova Machine N/A N/A Ht. #7X12 2012 Installed No

7. Description of Work Replaced body to. bonnet studs and nuts....._,_..
8. Tests Conducted:

Hydrostatic* [

Pneumatic* []

Nominal Operating Pressure []

Exempt Z Other ]

Pressure psi Test Temp.

O F tRecord test pressure and temperature Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3682

9. Remarks No Code Data Report available.

Applicable Manufacturers Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date October 30, 20 13 Owner or Owner's esgnee, -Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period // - /,Z to

/ 0 -.? / -12, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with thi inspection.

Commissions A,, J

,-5'

,YW-z-,a

/62--

Inspec Signature National Board, State, Province, and Endorsements D ate.

.20.

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI NOP-CC-5703-02 Rev. 01 Report Number 3691

1. Owner FirstEnerqv Nuclear Operatinq Company I Date 01/06/2014 (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

Beaver Valley Power Station (BVPS)

Sheet 1

of Unit No.

1 Order #200581153

2. Plant P.O. Box 4.

(NAME)

Shippinaport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Construction Services (NAME)

P.O. Box 4. ShiDoinaoort. PA 15077 RepairlReplacement Organization P.O. No-, Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A (ADDRESS)

4. Identification of System River Water (Q3)
5. (a) Applicable Construction.Code ANSI B31.1 1967 Edition, S'71 Addenda, Code Case --

(b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 E-2003A (c)

Applicable Section X1 Code Case(s): N/A

6. Identification of Components Corrected, National
Removed, ASME Name of Name of Manufacturer Board Other Year or Code Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Pipe Support Stone &

N/A N/A R-59 1976 Removed No Webster Pipe Support FirstEnergy N/A N/A VS-59A 2013 Installed No Tube Steel, Energy &

N/A N/A Ht. #A100040 2012 Installed No 6"x6"xl/2" Process Plate, 1-1/2" Energy &

N/A N/A Ht. 8105293 2008 Installed No Process Plate, 5/8" Energy &

N/A N/A Ht.

2009 Installed No Process

  1. 6107659, S/N: 03 Anchor Stud, Drillco Device N/A N/A Lot #9248-D 2006 Installed No 5/8" Anchor Stud, Drillco Device N/A N/A Lot #9249-D 2006 Installed No 5/8" Page 1 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl NOP-CC-5703-02 Rev. 01 Report Number 3691

7. Description of Work Removed existing pipe support, fabricated and installed a new one.
8. Tests Conducted:

Hydrostatic* EJ Pneumatic* EL Nominal Operating Pressure LI Exempt [

Other ]

Pressure psi Test Temp.

__F

_ "Record test pressure and temperature

9. Remarks No Code Data Reports available.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Thomas White Nuclear Engineer V Date January 06, 20 14 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period f--to

//-

'/- /1

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

S-,

J"/

Commissions BoardStat-T

, Province, an E re Inspct9 ignaureNational Board, State, Province, and Endorsements

/ -

,0

- 1,<7 Page 2 of 2