L-23-208, Submittal of Discharge Monitoring Report Cnpdes), Permit No. PA0025615
| ML23279A107 | |
| Person / Time | |
|---|---|
| Site: | Beaver Valley |
| Issue date: | 09/14/2023 |
| From: | Kristophel R Energy Harbor Nuclear Corp |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| L-23-208 | |
| Download: ML23279A107 (1) | |
Text
energy harbor September 14, 2023 L-23-208 eDMR for Electronic Submission Department of Environmental Protection Bureau of Water Quality Management 400 Waterfront Drive Pittsburgh, PA 15222
SUBJECT:
Beaver Valley Power Station 200 State Route 3016 P.O.Box4
. Shippingport, PA 15077:0004 Beaver Valley Power Station Discharge Monitoring Report CNPDES) Permit No.
PA0025615 Enclosed is the August 2023 NPDES Discharge Monitoring Report (DMR), Chemical Additives Usage Forms, Daily Effluent Monitoring Forms and Cooling Water Intake Monitoring Forms in accordance with the requirements set forth in the site NPDES permit.
A review of the data indicates no NPD6S permit Part A effluent limits were exceeded during the month.
Should you have any questions regarding the enclosed documents, please direct them to James Harvey, at 724-682-7358.
Sincerely, Robert Kristophel General Plant Manager
- gF2 5 rJf.~
Beaver Valley Power Station, Unit Nos. 1 and 2 L-23-208 Page3 Enclosure( s ):
A.
Monthly Discharge Monitoring Report B.
Chemical Additives Usage Forms C.
Daily Effluent Monitoring Forms D.
Cooling Water Intake Monitoring Forms cc:
Document Control Desk US NRC (NOTE: No new US NRC commitments are contained in this letter.)
L-23-208 ENCLOSURE A
3800-FM-BCW046212/2016 g pennsylvania r,,aJ OEP,\\Rl"1ENT OF ENVIRONMENTAL ISi!!!I" PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308-2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 188, SHIPPINGPORT PA, 15077 STAGE:
_F __ lnal=E"-'111'"'-ue--'-nt-'----------------
PARAMETERS REPORTED VALUES PARAMETER TMnJ)efalure (deg F) (00011 )
Sample Measurement Perml1 Requirement plf (00400)
Sample Measurement Permit Requirement Ammonia-Nitrogen (00610)
Sample Measurement Permit R6Qtlirement Phenotics, Total (32730)
Sample Measurement Permit Requlr.ment Ctw"omtum. Total (01034)
SampfeMeasuremflfll Permit Requirement Copper. Tot.N (01042)
SampteMea~
Permit Reqolremenl Iron, Tolal (01045)
Sample Measurement Permit Requirement Zinc, Total (01092)
Sample Measurement Permit Requirement Aluminum, Total (01105)
Sample Measurement Permit Requirement Fbw-(50050)
Sample Measurement Permit Requirement Total Reskluat Chlorine (TRC) (50060)
Sample Measurement Permit Requirement Nak:o H150M (51 698)
Sampte MenuJement Penni! Requirement Free Avaitable Chklrine (50064)
Sample Measi.wement Permit Requirement Mercury, Total (71900)
Sample Maas1M"emen1 Permit Requirement Hydrazine (8131 3)
Sample Measurement Permit Requirement F*cillty Sampling Point Comm*nts COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025615 001 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
Permit Expires:
Penntt Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS 90.1
' F 110 Daily Max 7.8 8.1 s.u.
6.0 9.0 lnstMin IMAX GG GG mgll Monitor&Report Monitor & Report Avg Mo DaifyMax
<.010 C.010 mglL MonHor &R-s>Oft Monitor& Report Avg Mo
- 0ailyMa, GG GG mgll
.2
.2 Avg Mo OaityMax
.0077
.0091 mglL Monitor & Report Monitor& Report A"9Mo Daily Max
.36
.56 mgll Monitor& Report Monitor& Report Avg Mo OailyMax GG GG mgll 1.0 1.0 Avg Mo Dally Max
.206
.3 mgll Monitor & Report Monitor& Report Avg Mo Daily Max 41.6 43.6 MGO Monitor& Report Monitor& Report
<vgMo Daly Max
<,05
.14 mglL
.5 1.25 Avg Mo IMAX
<.034
<.034 mglL
.034
.034 Avg Mo Dally Max
<.05
.1 moll
.2
.5 Avg Mo DallyMax
<.2
<.2 uglL Monltor&Report Monitor & Report Avg Mo Dally Max GG GG mg/L
.007
.007 Avg Mo OailyMax Privacy Polley I Security Polley Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 08/31/2023 10/31/2021 05/04/2021 SAMPLING FREQUENCY SAMPLING TYPE 1/day 1-S 1/day 1-S 1/Week.
o.. b 1/week Grab 1/week Gn,b 2/monlh Gfflb 2/monlh Gnob 24-Hr Composite 2/month Grab 2/month Gn,b 2/monlh Grab 2/monlh Gn,b 1/week 24-Hr Compo9ita 2/monlh Grab 2/moalh Gn,b Continuous Measured Coofuluoug Measured 1/INMk G.. b 1/wl!:ek Grab 2-1-Hr Composite 1/wuk 24*Hr Composite Continuous Re<onled Contmuous Ree0<ded 2/month Grab 2/moalh Gmb 1/week Grab
3800-FM-BCW046212/2016 G'
,~ CEPAR1"'ENT OF ENVIRONMENTAL S8 PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308-2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 198, SHIPPINGPORT PA, 15077 STAGE:
Flnal Effluent PARAMETERS REPORTED VALUES PARAMETER Flow (50050)
Sample Measwement Permit Requirement Faclllty Sampllng Point Comments COMMONWEAL TH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025615 002 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
Permit Expires:
Permit Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS
.046
.046 MGD Monitor & Repo41 Monitor & Report Avg Mo Daily Max Privacy Polley I Security Policy Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 08/31/2023 10/31/2029 05/04/2029 SAMPLING FREQUENCY SAMPLING TYPE 11w&ek Estimate 1/Week Estimate
3800-FM-BCW0462 12/2016 8
pennsylvanta J~ DEl'AR'ENT OF ENVIRONMENTAL Sl!!!/I PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308-2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 198, SHIPPINGPORT PA, 15077 STAGE:
Final Effluent PARAMETERS REPORTED VALUES PARAMETER Ammonia-Nitrogen (00610)
Sampfe Measurement Permit Requirement Aluminum, Total (01105)
S&mpe Measurement Permit Requirement Flow (50050)
Somple MeasUfement Permit Requ1remenl Nalco H150M (51698)
Sample Measurement Permit Requlremenl Mercury, Total (71900)
Sample Measurement Permit Requirement Hydrazine (81313)
Sample MHsurement Pormlt Requirement Facfflty Samptlng Point Comments COMMONWEAL TH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025e15 003 PERMIT NUMBER OLITFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
Permtt Expires:
Permtt Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS GG GG mg/l.
Monitor& Report Monitor & Report Avg Mo Daily Max
.24
.34 mg/l.
Monitor & Report Monitor & Report Avg Mo Daily Max
.137
.143 MGO Monltor&Report Monitor & Report A'9Mo Daily Mex
<.034
<.034 mg/l.
.034
.034 Avg Mo Daily Max
<.2
<.2 ug/L Monttor&Report Monllor &Report Avg Mo Daffy Max GG GG mg/l.
.007
.007 Avg Mo OailyMax Privacy Polley I Security Polley Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 08/31/2023 10/31/2029 0510412029 D
SAMPLING FREQUENCY SAMPLING TYPE 1/Wffk Grab 2/momh 24-Hr Composite 2/month 24-Hr Composite 2/monlh Estimate 2/monlh Esbmate 1/Wffk Grab 11week Grab 2/monlh Grab 2/moalh Grab 1/Wffk Grab
3800-FM-BCW0462 12/2016
~
pennsylvanta
,.==Of ENVIRONMENTAL NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308-2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 168, SHIPPINGPORT PA, 15077 STAGE:
Final Effluent PARAMETERS REPORTED VALUES PARAMETER Temperature (deg F) (00011)
Sample Measurement Pennit Requirement pH (00400)
Sample MeasLM"ement Permit Requirement Chromium. Total (01034)
Sample Measurement Pennit Requirement Copper, Total (01042)
Sample Measurement Permit Requirement Zinc, Total (01092)
Sample Measurement Pennlt Requirement Aluminum, Total (01105)
Sample Measurement Permit Requirement Flow (50050)
Sample Measurement Permit Requirement Total Residual ChloriM (TRC) (50060)
Sample Measurement Permit Requirement Free Available Chlorine (50064)
Sample Measurement Permit Requirement Facility Sampling Point Comments COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025615 004 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
Permit Expires:
Permit Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS 90.1 110 Daily Max 7.5 s.u.
6.0 9.0 Inst Min IMAX GG GG mg/L
.2
.2 Avg Mo Deily Mex
.0043
.005 mg/L Monitor&Report Monitor & Report Avg Mo Dally Max GG GG mg/L 1.0 1.0 Avg Mo Dally Max 1.1 mg/L Monitor& Report Monitor & A:eport Avg Mo Daily Max
.1 1.0 MGD Mooitor& Report Monitor & Report Avg Mo Daily Max
<.04
.05 mg/L
.5 1.25 Avg Mo IMAX
.04
.05 mg/L
.2
.5 Avg Mo OaifyMax Privacy Policy I Security Policy Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 08/31/2023 10/31/2021 05/04/2021 SAMPLING FREQUENCY SAMPLING TYPE 1/day 1-S 1/day 1-S 1_,
Grab 1/week Grab 1/week 24-Hr Composite 2/mooth Grab 2/month Grab 1/week 24-Hr Composite 2/month Grab 2/month Gc,b 1fweek Calcliation 1/week Calculatioo 1-k Grab 1/week Grab 1/week Grab 1/week Grab
3800-FM-BCW0462 12/2016 pennsylvania r.-rJ DEPAlm'1ErfTOFENVIRONMENTAL
'at§ PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308-2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 188, SHIPPINGPORT PA, 15077 STAGE:
Flnal Effluent PARAMETERS REPORTED VALUES PARAMETER Flow (50050)
Sample Measurement Permit Requirement Fac:Hlty Sampllng Point Comments COMMONWEAL TH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025815 009 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
Permit Expires:
Permit Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS
.016
.016 MGD Monitor &Report Monitor & Report A,gMo OattyMaK Privacy Policy I Security Polley Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 08/31/2023 10/31/2021 15IU4/2021 D
SAMPLING FREQUENCY SAMPLING TYPE 1/Week Estimate Estimate
3800-FM-BCW0462 12/2016 G'
pennsylvanfa
,~ DEPARTMENT OF ENVIRONMENT.Al as PAOT£CTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
1H E MARKET ST, AKRON OH, '-'308*2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 188, SHIPPINGPORT PA, 15077 STAGE:
Final Effluent PARAMETERS REPORTED VALUES PARAMETER T~atixa {deg F)(00011)
Sample Measuremanl Permit Requirement pH (00400)
Semplt, Measurement Peffl'lil Requirement Fbw(50050)
Sampfe Measurement Permit Requirement Total Residual CNorine (TRC) (50060)
Sample MeastHment Permit Requirement Nalco H1SOM (51698)
Sample Me&SIM'emttnl Permit Requiremenl Free Avaitabte ChforiM (50064)
Sample MeaS1Xement Permit Requirement Faclltty Sampling Point Comm.nts COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025115 007 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
Permtt Expires:
Permtt Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS GG "F
110 Daily Max GG GG s.u.
6,0 9.0 Inst Min IMAX GG GG MGD Monllor & Repac1 Mondor & Report A,gMo Dally Max GG mg/L
.20
- DallyMa, GG GG mgll
.034
.034 AV'o!MO O*ilyMa:ic GG GG mg/L
.2 Avg Mo Daily Max Privacy Polley I Security Polley Copyright ©2016 CommonweaHh of Pennsylvania. All Rights Reserved Monthly 08/01/2023 01131/2023 10/31/2028 0MM/2028 D
SAMPLING FREQUENCY SAMPLING TYPE 1/day 1-S 1/week G,ab Estsmate O..b O..b G,ab
3800-FM-BCW0462 12/2016 pennsylvania J~ DEPARTMENT OF ENVIRONMENTAL
'a8 PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 443011-2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 118, SHIPPINGPORT PA, 15077 STAGE:
Final Effluent PARAMETERS REPORTED VALUES PARAMETER Temperature (deg F) (00011)
Sample MeaSI.HITl8nl Permit Requirement pH (00400)
Sample Measi.ement Permit Requirement Flow (50050)
Sample Ma8Surement Pemut Requirement Total Residwtl Chlonne (TRC) (50060)
~
Measurement Permit Requirement Nalco H150M (51698)
Sample Measurement Permit Requirement Free Availabttt Chklrine (50064)
Sample Measurement Permit Requirement Mercury, Tolal (71900)
Sample Meaaurement Permd Requirement Faclftty S,impUng Point Comment.a COMMONWEAL TH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025615 010 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
PermH Expires:
PermH Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS 84.0
' F 110 Daily Max 7.3 7.7 s.u.
0.0 9.0 Inst Min IMAX 3,89 5.04 MGD Momtor& Report Monitor& Report Avg Mo DaltyMax
.08 mgll.
.20 DaltyMax GG GG mgll.
.034
,034 Avg Mo DtllyMax
.04
.06 mgll.
.2
.5 Avg Mo Daily Max
<.2
<.2 ug,I.
Monitor& Report Monitor& Report Avg Mo Daily Max Privacy Polley I Security Polley Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 0l/01/2023 08/31/2023 10/31/2029 OSICM/2029 SAMPLING FREQUENCY SAMPLING TYPE 1/day 1/day 1/Week Grab Grab 1/week Measured Me.,,un,d 1/weok Grab Grab 1/week 24*Ht Composite 1/WHk Grab 1/week Grab 2/mo,lh Grab 2/m<ffllh G'"b
3800-FM-BCW046212/2016 8
pennsylvanta
,~ OEPARTMEKTOFENVIRONMENTAL S!l!!I PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308-2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 188, SHIPPINGPORT PA, 15077 STAGE:
FIIIIII Effluent PARAMETERS REPORTED VALUES PARAMETER Fk>w (50050)
Sample Measu-emenl Penntt Requirement Mercury. Total (71900)
Sempte MeastKement Permit Requirement Facility S.mpllnt Point Comm*nb COMMONWEAL TH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025815 011 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
Pemitt Expires:
Pem,tt Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS MGD Monitor& Reporl Monitor& Report A"IIMo Dally Ma*
<.2
<.2 ug/1.
Monitor& Report Mor'lltor & Report Avg Mo Daily Max Privacy Polley I Security Policy Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 Ol/3112023 10/31/2021 051114/Z021 SAMPLING FREQUENCY SAMPLING TYPE 1/wMk Estimate EatlfflaN 2"non1" G,ab 2/month G"'b
3800-FM-BCW046212/2016 g pennsylvania r~ D£PAA1"'ENT OF ENVIRONMENTAL
- a:1!!!!11 PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308°2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 188, SHIPPINGPORT PA, 15077 STAGE:
Final Effluent PARAMETERS REPORTED VALUES PARAMETER pH (00400)
Sarnpfe Measurement Permit ReqUlrement Cadmium. Total (01027)
Sample MeaS\\a'em&nt Permit Requirement Copper, Total (01042)
Semple Measurement Permit Requirement Zh:, Total (01092)
Sample Measi.ement Permit Requirem.nt Flow (50050)
Sample Measurement Permit Requirement FaclHty hmpllnsi Point Comments COMMONWEAL TH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA00251115 012 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
Permtt Expires:
Permtt Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS s.u.
6.0 9.0 Inst Min IMAX mg/L Monltor&Report Monitor& Report Avg Mo Daily Max mg/L MonitOl"&Report MonrtOI' & Report Avg Mo Daily Max mg/L Monti.or & RepcNt Monitor& Report Avg Mo DellyMa><
MGO Monitor & Report Monitor& Report Avg Mo Dally Max Privacy Polley I Security Polley Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 0l/01/2023 08/31/2023 10/31/2028 05/04/2028 El SAMPLING FREQUENCY SAMPLING TYPE 2/month Grab 2/month Grab 2/month Grab 2/month G'"b 2/month Estimate
3800-FM-BCW046212/2016 8
,.-1111'3 DEPARTMENT OF ENVIRONMENTAL S!!!f PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308-2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 168, SHIPPINGPORT PA, 15077 STAGE:
'-F"-ln"'lll'"'E"'lll""u"-ent=---------------
PARAMETERS REPORTED VALUES PARAMETER pH (00400)
Sample Measurement Permit Requlremenl Copper, Totaf (01042)
Sample MeasUfemenl Permit Requirement Flow (50050)
Sample Measurement Permit Requirement Faellty Sampllng Point Comments COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025615 013 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
Permit Expires:
Perm~ Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS 7.8 7.8 s.u.
6.0 9.0 Inst Min IMAX
.0064
.0083 mg/L Monltor&Report Monitor & Report Avg Mo Daily Max
.002
.002 MGO Monitor&Report Monitor & Report Avg Mo Daily Max Privacy Polley I Security Policy Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 06/31/2023 10/31/2021 05/04/2021 SAMPLING FREQUENCY SAMPLING TYPE 2/month Grab 2/month Grab 2/mo,lh Grab 2/monlh Grab 2/monlh Estimate 2/month Estimate
3800-FM-BCW046212/2016 pennsylvanta
,~ DEPARTMENT OF EN'IIRONMENTAL S!!!!I PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308-2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 198, SHIPPINGPORT PA, 1son STAGE:
Internal Monttortng Point PARAMETERS REPORTED VALUES PARAMETER pH(00400)
Sample MeaS1181Tl&nl Permit Requirement Total Suspended Solids (00530)
$$1Tlple Measurement Permit Requirement Oil and Grease (00556)
Sempw Measurement Permrt. Requirement Ammonia.Nitrogen (00610)
Sampte Measurement Permit Requirement Flow (50050)
Sampfe Measixement Permit Requirement Hydrattle (81313)
Sample Measurement Permit ReqUlrement Faclffy Sampllng Point Comments COMMONWEAL TH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025e15 101 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
Penmlt Expires:
Penmlt Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VA.LUE UNITS 6.1 6.9 s.u.
8.0 9.0 Inst Min IMAX
<4.0
<4,0 mg/L 30.0 100.0 Avg Mo Dally Max
<4.7
<5.1 mg/L 15.0 20.0 A"9Mo OaltyMax GG GG mg/I.
Monhor&Report Monitor& Report Avg Mo OtfityMax
.008
.009 MGO Monitor& Repor1 Monitor& RePort A"9Mo Dally Max GG GG mg/L Monitor&Report Monitor & Report Avg Mo Daily Max Privacy Polley I Security Polley Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 08/31/2023 10/31/2021 05l04/2021 D
SAMPLING FREQUENCY SAMPLING TYPE G.. b 1/week Grab 1/week Grab 1/week Grab 1/Week Grab 1/WMk Grab 1/Week Grab Esbmate 1/week Estimate 1/Week Grab
3800-FM-BCW046212/2016 e
,~ DEPNITT1ENTOFENVIRONMENTAL
~
PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308-2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 198, SHIPPINGPORT PA, 15077 STAGE:
lntemal Monitoring Point PARAMETERS REPORTED VALUES PARAMETER pH(00400)
Sample Measurement Permit Requirement Total Suspended Solids (00530)
Sample Measurement Permit Requirement Oil and Grease (00556)
Sample Measurement Permit R&quirement flow (50050)
Samp4e Measurement Permit Requirement Facility Sampling Point Comm1nt1 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025915 102 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
Permit Expires:
Perm~ Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS 7.4 7.5 s.u.
6.0 9.0 Inst Min IMAX
<4.0
<4.0 mg/I.
30.0 100.0 Avg Mo Daily Max
<5.0
<5,1 mg/I.
15.0 20.0
.... Mo OaityMa1t
.001
.001 MGD Monitor& Report MonllOf& Repon
.,.Mo Dally Mak Privacy Policy I Security Policy Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 08/31/2023 10/31/2029 05/04/2029 SAMPLING FREQUENCY SAMPLING TYPE 2/month Grab 2/mo,th Grab 2/mo,lh Grab 2/mo,th Grab 2/mo,th Grab 2/month Grab 2/month Estimate 2/month Estimate
3800-FM-BCW0462 12/2016
~
.,.==-Of ENVIRONMENTAL NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, "4308°201*
FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 1A, SHIPPINGPORT PA, 15077 STAGE:
Internal Monltortnp Point PARAMETERS REPORTED VALUES PARAMETER pH(OO<OO)
Sampfe MellSIXlt!Tlflnt Pennit R9Qllirement Total Suspended Solids (00530)
Sample MeaSLnmenl Permit Requirement Oil and Grease (00556)
Sample Meaiuement P&rmit Requirement Fb.1,(50050)
SampfeMeaswement Pennit Requirement Facility Sampling Point Comments COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (OMR)
PA00251115 103 PERMIT NUMBER OUTfALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
Permit Expires:
Permit Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS 7,0 7.2 S.U.
6.0 9.0 Inst Mn IMAX
<4.2 4,4 mg/I.
30.0 100.0 Avg Mo Daily Max
< 5.0
<5.1 mgll 15.0 20.0 A"{IMo Dally Max
.139
.152 MGO Monitor& Repo,1 Monitor& Report A"VMo Oaity h.181l Privacy Polley I Security Policy Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 01/31/2023 10/31/2021 05/04/2021 SAMPLING FREQUENCY SAMPLING TYPE 2/month Gmb 2/month Gmb 2/monlh See Permit 2/mooth See Permit 2/mooth G,ab 2/monlh Gn,b
'""°'""
Estimate 2/monlh Estimate
3800-FM-BCW046212/2016 g pennsylvania r.-t DEMRTMENT OF ENWlONMENTAL
'st!f PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308-2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 188, SHIPPINGPORT PA, 15077 STAGE:
Internal Monitoring Point PARAMETERS REPORTED VALUES PARAMETER Flow (50050)
Sample Measurement Permit Requirement Total Residual Chlorine (TRC) (50060)
Sample Measurement Permit Requirement Faelllty Sampllng P~nt Comm*nts COMMONWEAL TH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025815 108 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
Permtt Expires:
Permtt Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS MGD Monitor& Report Monitor& Report A,gMo Daily Max mgll Monitor & Report Monltot & Report Avg Mo Daily Max Privacy Policy I Security Policy Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 08/31/2023 10/31/2028 05/04/2028 0
SAMPLING FREQUENCY SAMPLING TYPE Weekly when Discharging Estimate Weekly when Discharging Grab
3800-FM-BCW046212/2016 pennsylvania r-,iJI DEPARTMENT Of ENVIRONMENTAL aZ!!/1 PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308*2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 168, SHIPPINGPORT PA, 15077 STAGE:
lntemal Monitoring Point PARAMETERS REPORTED VALUES PARAMETER pH (00400)
Sample Measurement Permit Requirement To1al Suspended Solids {00530)
Sample Measurement Permit Requirement Oil and Grease (00556)
Sample Measurement Permit Requirement Flow (50050)
Sampte Measurement Permit Requirement Facility Sampling Point Comments COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025615 111 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporling Frequency:
DMR Effective From:
DMR Effective To:
Permit Expires:
Permft Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS 6.9 7.9 S.U.
6.0 9.0 Inst Min IMAX
<5.0 7.0 mg/\\.
30.0 100.0 Avg Mo Daily Max
<4.6
< 5.2 mg/L 15.0 20,0 Avg Mo Daily Max
.002
.002 MGO Monitor & Report Monitor & Report Avg Mo Dally Max Privacy Policy I Security Policy Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 08/31/2023 10/31/20211 05/04/20211 SAMPLING FREQUENCY SAMPLING TYPE 11week Grab 1fweek Grab 1/week Grab 1fweek Grab 1/Week Grab 1/week Grab 1/week Estimate Estimate
3800-FM-BCW046212/2016 8
pennsylvania J.il!!J DEPARTMENT OF ENVIRONMENTAL a:t!!I PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308-2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 168, SHIPPINGPORT PA, 150TT STAGE:
Internal Monitoring Point PARAMETERS REPORTED VALUES PARAMETER pH (00400)
Sample Measurement Permit Requirement Total Suspended Solids (00530)
Sample Measurement Permit Requirement Oil end Grease (00556)
Sample Measurement Permit Requirement Flow (50050)
Sample Measurement Permit Requirement FacMily Sampling Point Comments COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025615 211 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
Permit Expires:
Permit Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS 6.8 7.7 s.u.
6.0 9.0 Inst Min IMAX
<6.0 7.6 mg/I.
30.0 100.0 Avg Mo Daily Max
<4.8
< 5.6 mgll 15.0 20.0 Avg Mo Daily Max
.002
.002 MGD Monitor & Repor1 Monitor & Report Avg Mo Daily Max Privacy Policy I Security Policy Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 08/31/2023 10/31/2028 05/04/2028 SAMPLING FREQUENCY SAMPLING TYPE 1/week Grab 1/week Grab 1/week Grab 1/week Grab 1fweek Grab 1/w&ek Grab 1/week Estimate 1/week Estimate
3800-FM-BCW0462 12/2016 pennsylvania
,,i/lllfl DEl'ARTM£NT OF ENVIROHMENTAL
.a PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308-2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 188, SHIPPINGPORT PA, 15077 STAGE:
Internal Monitoring Point PARAMETERS REPORTED VALUES PARAMETER Total Suspended Soltds (00530)
Sample Measurement Permit Requirement OIi and Grease (00556)
Sample Measurement Permit Requirement Fk>w (50050)
Sample MeasLKement Permit Requ,rement FaelNty Sampllng Point Comments COMMONWEAL TH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025S15 301 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
Permit Expires:
Permit Application Due:
No Oischarge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS mg/L 30.0 100.0 Avg Mo Daily Max mglL 15.0 20.0 Avg Mo Daily Max MGO Monrtor& Report Monitor& Repo,1 A"9Mo Daty Max Privacy Polley I Security Policy Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 08/31/2023 10/31/2028 05/04/2028 0
SAMPLING FREQUENCY SAMPLING TYPE Grab 2/""'"th a.. o Estimate
3800-FM-BCW046212/2016 G
pennsylvanta
,~ OEPAR'ENT OF ENVIRONMENTAi.
.:S PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308-2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 10, SHIPPINGPORT PA, 150TT STAGE:
Internal Monitoring Point PARAMETERS REPORTED VALUES PARAMETER pH(OO<OO)
SampfeMeasu-ement Permit Requirement Total 5u$J)ended Sold! (00530)
Sample Measurement F'ermlt Requirement OIi and Gre11Se (00556)
Semple Measixement Permit Requirement flow(50050)
&lmpe Measurement Permit Requirement Faclity Sampling Point Comments COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA00254115 303 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
Permit Expires:
Permit Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS 6.5 6.6 s.u.
6.0 9.0 Inst MIi\\
IMAX
<4,0
<4.0 mg/L 30.0 100.0 Avg Mo DailyMax
< 4.9
<4,9 mg/L 15.0 20.0 Avg Mo Dally Max
.019
.056 MGD Monltor &Repo,t Monllof &Report A"!!Mo OallyMax Privacy Polley I Security Polley Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 01131/2023 10/31/2021 05/04/Z029 D
SAMPLING FREQUENCY SAMPLING TYPE 2/monlh
<l<>b 2/monlh G,ab 2/monlh o.. b 2/monlh Grab 2/monlh Grab 2/moolh G,.b Estimate
3800-FM-BCW046212/2016 pennsylvania
,~ D£1'ARTMENTOFENVIRONMENTAL a:t!§ PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308-2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 168, SHIPPINGPORT PA, 15077 STAGE:
Internal Monitoring Point PARAMETERS REPORTED VALUES PARAMETER pH (00400)
Sample Measurement Permit Requirement Tole.I Suspended Solids (00530)
Sample Measurement Permit Requirement Oil end Grease (00556)
Sample Measurement Permit Requirement Flow (50050)
Sample Measurement Permit Requirement Facility Sampling Point Comments COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025615 313 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
Permij Expires:
Permij Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS 7.0 7.7 s.u.
s.o 9.0 Inst Min IMAX
<5.2 7.8 mglL 30.0 100.0 Avg Mo Daily Max
<4.6
<:5,2 mg/L 15 20 Avg Mo Dally Max
.002
.002 MGD Monitor & Repor1 Monitor& Report A,gMo Daily Max Privacy Policy I Security Policy Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 08/31/2023 10/31/2026 05104/2026 SAMPLING FREQUENCY SAMPLING TYPE 1/week Grab 1/week Grab 1/week Grab 1/week Grab 1/week Grab 1/week Grab 1/week Estimate 1/week Eslimale
3800-FM-BCW046212/2016 pennsylvania J~ DEPARTMENT OF ENVIRONMENTAL a::t!I PAOTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308*2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 168, SHIPPINGPORT PA, 1son STAGE:
Internal Monitoring Point PARAMETERS REPORTED VALUES PARAMETER pH (00400)
Sample Measuremenl Permit Requirement Total Suspended Solids (00530)
Sample Measurement Permit Requirement Oil and Grease (00556)
Sample Measurement Permit Requirement flow (50050)
Sample Measurement Permit R.qulr*ment Facility Sampllng Point Comments COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025615 401 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporling Frequency:
DMR Effective From:
DMR Effective To:
Permit Expires:
Permn Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS 7.5 s.u.
6.0 Inst Min
<4.0
<4.0 mg/I.
30.0 100.0 Avg Mo DailyMax
<5.1
<5.2 mg/I.
15.0 20.0 Avg Mo Dally Max
.001
.001 MGD Monitor & Report Monitor& Report Avg Mo Daily Max Privacy Policy I Security Policy Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 08/31/2023 10/31/2028 05/04/2026 SAMPLING FREQUENCY SAMPLING TYPE 2/mo,rtt, Grab 2/month Grab 2/month Grab 2/mo,th Grab 2/month Grab 2/month Grab 1/week Estimate 1/week Eslimate
3800-FM-BCW046212/2016 g pennsylvania
,~ ll£P,\\IITT'l£HT OF ENVIRONMENTAL a:t5 PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308-2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 168, SHIPPINGPORT PA, 15077 STAGE:
Internal Monitoring Point PARAMETERS REPORTED VALUES PARAMETER pH (00400)
Sample MeasUJemenl Pennlt Requirement Total suspended Sollds (00530)
Sampte Measurement Permit Requirement Oil and Grease (00556)
Sample Measurement Permit Requirement Ammonia-Nitrogen (00610)
Sample Measurement Permit Requirement Chrorrium, Total (01034)
Sample Measurement Pennie Requiremenl Zinc, Total (01092)
SarnJ)MJ Measurement Permit Requirement FkJw (50050)
Sampte Measurement Pennit R.-quirement Total Residual Chlorine (TRC) (50060)
Sample Measurement Permit Requirement Nalco H150M (51698)
Sample Measurement Permit Requirement Hydl°lUM (81313)
Sample Measurement Permit Requirement Facltlty Sampting Point Comment*
COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025e15 403 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
Permit Expires:
Permit Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS s.u.
6.0 9.0 lnstMrn IMAX mg/L 30.0 100.0 Avg Mo Daily Max mg/\\.
15.0 20.0 Avg Mo Daily Max mg/\\.
MonltOf"& Report Monitor & Report Avg Mo Daily Max mg/L
.2
.2 Avg Mo DailyMax mg/L 1.0 1.0 Avg Mo D&ityMax MGO MonltOf& Report Monitor& Report A,gMo Daily Max mg/\\.
.5 125 Avg Mo IMAX mg/\\.
.034
.034 Avg Mo Daily Max mg/L
.007
.007 Avg Mo Daily Max Privacy Policy I Security Polley Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 08/31/2023 10/31/2028 05/04/2028 El SAMPLING FREQUENCY SAMPLING TYPE Weekly when Discharging G,ab Weekly when Discharging Grab W11&kly when Dischargtng G,ab WHkly when o.ctiarglng Gnob Weekty when Discharging Gnob Weekty whon Discharging Gnob Woekly when Discharging Estil'Nllte Weekly when Discharging Grab Weekly when Discharging G,ab Weekly v.tlen CMscharging G,ab
3800-FM-BCW046212/2016 G'
pennsylvania J~ DEl'ARTMENT OF ENVIRONMENTol.l Sl!!/1 PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH,.U308*2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 1118, SHIPPINGPORT PA, 15077 STAGE:
Internal Monitoring Point PARAMETERS REPORTED VALUES PARAMETER pH (00400J Semple Measurement Permit Requirement Total suspended Solids (00530)
Samt)le Measurement Permit Requirement Oil and Grease (00556)
~
Measurement Perm,t Requirement Ammorva-Nrtrogen (00610)
Sampte MeaSU"ernent Permit Requirement Fk>w (50050)
Sample Measurement Permit Requirement Hydrazine(81313)
Sample Measia"emenl Permit Requirement Faclffty Sampling Point Comments COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA00254115 801 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporting Frequency:
DMR Effective From:
DMR Effective To:
PermH Expires:
PermH Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS S.U.
6.0 9,0 Inst Min IMAX mg/L 30.0 100.0 Avg Mo DaityMax mg/L 15.0 20.0 Avg"° Dally Max mg/L Monltor&Reporl Monitor& Report Avg Mo OolyMax MGO Monitor& Report Monitor & Report Avg Mo Dally Max mg/L Monttor & Repo11 Monitor & Report Avg Mo Daily Max Privacy Polley I Security Polley Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 08/31/2023 10/31/2028 05/04/2028 B
SAMPLING FREQUENCY SAMPLING TYPE 1/We<,k Grab 1/week Grab Grab 1/week Grab 1/Week Estimate 1/Week G,ab
3800-FM-BCW046212/2016 8
,~ DEPARTMENT OF ENVJ!IONMENTAL a:!!f PROTECTION NAME:
ENERGY HARBOR NUCLEAR CORP ADDRESS:
168 E MARKET ST, AKRON OH, 44308-2014 FACILITY:
FIRSTENERGY BEAVER VALLEY POWER STATION 1 LOCATION:
PA ROUTE 168, SHIPPINGPORT PA, 15077 STAGE:
Internal Monitoring Point PARAMETERS REPORTED VALUES PARAMETER pH (00400)
Sample Measurement Permit Requirement To1al Suspended Solids (00530)
Sample Measurement Permit Requirement Oil and Grease (00556)
Sample Measurement Permit Requirement Ammonia-Nitrogen (00610)
Sample Measurement Permit Requiremenl Fkwv(50050)
Sample Measurement Permit Requirement Hydrazine (81313)
Sample Measuremenl Permit Requirement Faclffty Sampling Point Comments COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
PA0025615 701 PERMIT NUMBER OUTFALL NUMBER MONITORING PERIOD YEAR MO DAY YEAR MO DAY FROM 2023 08 01 TO 2023 08 31 Reporling Frequency:
OMR Effective From:
DMR Effective To:
Permit Expires:
Perm~ Application Due:
No Discharge:
QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE VALUE UNITS VALUE VALUE VALUE UNITS S.U.
6.0 9.0 Inst Min IMAX mg/L 30.0 100.0 Avg Mo Daily Max mg/L 15.0 20.0 Avg Mo Dally Max mg/L Monitor&Report Monllor& Report Avg Mo Dally Max MGD Monitor & Report Monitor & Report Avg Mo Dally Max mg/L Monitor & Report Monitor & Report Avg Mo Daily Max Privacy Policy I Security Policy Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved Monthly 08/01/2023 08131/2023 10/31/2026 05/04/2026 0
SAMPLING FREQUENCY SAMPLING TYPE 1/week Grab 1/week Grab 1/week Grab 1!week Grab 1/week Estimate 1/week Grab
3800-FM-BCW046212/2016 pennsylvania
,~ OEP,\\Rl"1ENT Of ENVIRONMENTAl
'ata PROTECTION ATTACHMENT DETAILS FIie Na~
Cover Letter BVPS DMR Aug 23.pdf COMMONWEAL TH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER DISCHARGE MONITORING REPORT (DMR)
Attachment Type Uploaded Tlme Cover letter 2023-09-19T07 :02:53--04:00 Attachment Comments BVPS August 2023 Cooling Water ln1ake Form1.pdf Otho<
2023-09-15T09:22:31-04:00 BVPS August 2023 Cooling Water Intake Monitoring Forms BVPS August 2023 Deity Effluent Fom,s.pctf Daily Effluent Monitoring Form 2023-09-15T09:21 :33-04:00 BVPS August 2023 Chemk:al Additives Usage Forms.pdf Chemk:9' Addilives Usage Form 2023-09-15T09:22:06-04:00 PERMIT VIOLATIONS I.....,_.ID I............... I..........,...
UmNT,,,_
- --~
UnN Samplng Point Cauu Of Non-Compllann UNAUTHORIZED DISCHARGES Ewnt ltwt DD lvffll f.nd 0..
0... and nm. Ola,c,ownd Oiachatgad OTHER PERMIT VIOLA TIO NS I -*
ID I Sampling Point Paramet.r COMMENT DETAILS c.........
Operator Name SUBMISSION INFORMATION SUBMITTED BY "Pursuant to the Pennsylvania Electronic Transactions Act-Act 69, effective January 15, 2002, you are about to engage In an GREENPORT USER electronic transaction with the Commonwealth of Pennsylvania. You are submitting official information. You certify under penalty of law that this document and all attachments were prepared under your direction or supervision in accordance with a system designed to assure that qualified personnel gather and evaluate the information submitted. Based on your inquiry of rkrlstophel the person or persons who manage the system or those persons directly responsible for gathering the information, the informatlon submitted Is, to the best of your knowledge and belief, true, accurate and complete. You are aware that any false statement may be subject to substantial civil and criminal penalties, including 18 P.S. saction 4904 (relating to unswom falsification to authorities).
Privacy Polley I Security Polley 0,-,.tor Cwtlllcatlon NurnlMr TELEPHONE Robert Krlstophel (724)
SUBMITTED BY FULL NAME AREA CODE Copyright ©2016 Commonwealth of Pennsylvania. All Rights Reserved 682-7773 NUMBER oat.andlhMDEP Notlfted -
Opentor Contact NurnMr DATE 2023 09 YEAR MO Commtnts 25 DAY
L-23-208 ENCLOSURE B
~
pennsylvania SUPPLEMENTAL REPORT - CHEMICAL ADDITIVES USAGE 3800-FM-BCW0439 3/2014
~
DEPARTMENT OF ENVIRONMENTAL PROTECTION Facility Name:
Beaver Valley Power Station - Unit 1 Month:
_Au g_u_s_t _______ _
Year:
2023 Municipality:
Shippingport Borough County:
Beaver NPDES Permit No.:
PA0025615 Outfall:
001 Watershed:
Ohio River Renewal application due 180 days prior to expiration.
This permit will expire on:
October 31, 2026 Chemical Names Control Brom CB-Surfactant Dispersant Nalco Acti Brom Nalco Biocide Nalco Dechlorination Bleach Liquichlor 70 Nalco 73550 3DT-120 1318 H-150M Nalco 7408 Nalco CL-50 Dav gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons 1
690.0 0.0 0.0 28.0 0.0 0.0 0.0 0.0 2
801.0 31.0 0.0 28.0 0.0 0.0 38.0 0.0 3
1429.0 0.0 0.0 28.0 0.0 0.0 60.0 0.0 4
440.0 10.0 0.0 28.0 0.0 0.0 53.0 0.0 5
759.0 36.0 0.0 28.0 0.0 0.0 57.0 0.0 6
499.0 24.0 0.0 28.0 0.0 0.0 51.0 0.0 7
869.0 33.0 0.0 28.0 0.0 0.0 57.0 0.0 8
1214.0 0.0 0.0 28.0 0.0 0.0 58.0 0.0 9
694.0 12.0 0.0 28.0 0.0 0.0 56.0 0.0 10 1137.0 0.0 0.0 28.0 0.0 0.0 52.0 0.0 11 611.0 26.0 0.0 28.0 0.0 0.0 51.0 0.0 12 521.0 17.0 0.0 28.0 0.0 0.0 49.0 0.0 13 517.0 17.0 0.0 28.0 0.0 0.0 48.0 0.0 14 1023.0 42.0 0.0 28.0 0.0 0.0 74.0 0.0 15 1221.0 34.0 0.0 28.0 0.0 0.0 60.0 0.0 16 854.0 40.0 0.0 28.0 0.0 0.0 55.0 0.0 17 949.0 0.0 0.0 28.0 0.0 0.0 61.0 0.0 18 617.0 29.0 0.0 28.0 0.0 0.0 55.0 0.0 19 661.0 32.0 0.0 28.0 0.0 0.0 50.0 0.0 20 702.0 27.0 0.0 28.0 0.0 0.0 50.0 0.0 21 759.0 22.0 0.0 28.0 0.0 0.0 64.0 0.0 22 1088.0 0.0 0.0 28.0 0.0 0.0 58.0 0.0 23 775.0 31.0 0.0 28.0 0.0 0.0 49.0 0.0 24 1104.0 0.0 0.0 28.0 0.0 0.0 65.0 0.0 25 489.0 25.0 0.0 28.0 0.0 0.0 48.0 0.0 49.0~
26 791.0 48.0 0.0 28.0 0.0 0.0 0.0 27 766.0 38.0 0.0 28.0 0.0 0.0 50.0 0.0 28 709.0 33.0 0.0 28.0 0.0 0.0 60.0 0.0 29 0.0 0.0 0.0 28.0 0.0 105.0 30.0 0.0 30 1015.0 55.0 0.0 28.0 0.0 0.0 64.0 0.0 31 1311.0 0.0 0.0 28.0 0.0 a.if 64.0
-0.0 Average 806.9 21.4 28.0 3.4 52.8 Maximum 1,429.0 55.0 28.0 105.0 74.0 I certify under penalty of law that this document was prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. See 18 Pa. C.S. § 4904 (relating to unswom falsification).
Prepared By: James Harvey
Title:
Senior Nuclear Specialist License No.:
Date:
_g_n_/_2_0_2_3 _____________ _
lbs
~
~
~
l 3800-FM-BCW0439 3/2014
~
e~~~~!;~~.~~o~ CTioN SUPPLEMENTAL REPORT - CHEMICAL ADDITIVES USAGE Facility Name:
Beaver Valley Power Station - Unit 2 Month:
August Year:
_2_02_3 ___ _
Municipality:
Shippingport Borough County:
Beaver NPDES Permit No.:
PA0025615 Outfall:
_0_0_1 ___ _
Watershed:
Ohio River Renewal application due 180 days orior to expiration.
This permit will expire on:
October 31, 2026 Chemical Names Control Brom CB-Surfactant Dispersant Nalco Biocide Nalco Dechlorination Bleach Liquichlor 70 Nalco 73550 3DT-120 H150-M Nalco 7408 Dav gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons 1
0.0 0.0 0.0 31.0 0.0 0.0
~
2 747.0 24.0 27.0 31.0 0.0 0.0 3
0.0 0.0 0.0 31.0 0.0 0.0 4
765.0 24.0 27.0 31.0 0.0 0.0 5
626.0 19.0 27.0 31.0 0.0 0.0 6
491.0 19.0 27.0 31.0 0.0 0.0
~
7 0.0 0.0 0.0 31.0 0.0 0.0 8
0.0 0.0 0.0 31.0 0.0 0.0 9
971.0 33.0 27.0 31.0 0.0 0.0 10 0.0 0.0 0.0 31.0 0.0 0.0 11 655.0 20.0 27.0 31.0 0.0 0.0 12 582.0 17.0 30.0 31.0 0.0 0.0
~
13 582.0 17.0 0.0 31.0 0.0 0.0 14 665.0 37.0 27.0 31.0 0.0 0.0 15 356.0 0.0 0.0 31.0 0.0 0.0 16 651.0 23.0 27.0 31.0 0.0 0.0 17 0.0 0.0 0.0 31.0 0.0 0.0 18 485.0 22.0 0.0 31.0 0.0 0.0
~
19 526.0 28.0 27.0 31.0 0.0 0.0 20 485.0 26.0 27.0 31.0 0.0 0.0 21 1187.0 59.0 27.0 31.0 0.0 0.0 22 0.0 0.0 0.0 31.0 0.0 0.0 23 834.0 31.0 27.0 31.0 0.0 0.0 24 0.0 0.0 0.0 31.0 0.0 0.0 25 550.0 26.0 0.0 31.0 0.0 0.0
-~
26 367.0 17.0 27.0 31.0 0.0 0.0 f--
27 440.0 21.0 27.0 31.0 0.0 0.0 28 994.0 53.0 27.0 31.0 0.0 0.0
~
29 0.0 0.0 0.0 31.0 0.0 0.0 30 963.0 44.0 27.0 31.0 0.0 0.0 31 0.0 0.0 0.0 31.0
- 0. 0.0 Average 449.1 18.1 14.9 31.0 Maximum 1,187.0 59.0 30.0 31.0 I certify under penalty of law that this document was prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. See 18 Pa. C.S. § 4904 (relating to unsworn falsification).
Prepared By: James Harvey License No.: -----------------
Title:
Senior Nuclear Specialist Date:
9n/2023 lbs
ft e.~~!!~~l~~.~~a?.cnaN 3800-FM-BCW0439 3/2014 SUPPLEMENTAL REPORT - CHEMICAL ADDITIVES USAGE Facility Name:
Beaver Valley power Station Month:
_Au__.g.... u_s_t _______ _
Year:
2023 Municipality:
Shippingport Borough County:
_B_e_a_v_e_r _____ _
NPDES Permit No.:
PA0025615 Outfall:
003 Watershed:
Ohio River Renewal application due 180 days prior to expiration.
This permit will expire on:
October 31, 2026 Chemical Names RO Antiscalant Klaraid IC1172 Hypersperse Coagulant Dav gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons 1
0.0 0.87 2
0.0 0.72 3
0.0 0.0
~
4 0.0 1.09
~-
5 0.0 0.29 6
0.0 0.0
-- ~
-- ~
- ~ --
7 0.0 1.02
-- ~
8 0.0 1.02
~
~
9 0.0 0.58 10 0.0 0.0 11 0.0 1.09 12 0.0 0.29 13 0.0 0.0 14 0.0 1.02 15 0.0 0.87 16 0.0 0.87
~
17 0.0 0.0 18 0.0 1.02 19 0.0 0.29 20 0.0 0.0 21 0.0 1.02 22 0.0 0.94 23 0.0 0.95
~
24 0.0 0.29 25 0.0 1.09 26 0.0 0.0 27 0.0 0.0 28 0.0 0.58
~
~ -
29 0.0 0.87 30 0.0 0.73 31
-0:0 0.0 Average 0.6 Maximum 1.1 I certify under penalty of law that this document was prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. See 18 Pa. C.S. § 4904 (relating to unsworn falsification).
Prepared By: James Harvey License No.: -----------------
Title:
Senior Nuclear Specialist Date:
9n/2023 lbs
~
~
l 3800-FM-BCW0439 3/2014 t
P PA~~!!~!O~ E~~!~CTION SUPPLEMENTAL REPORT - CHEMICAL ADDITIVES USAGE Facility Name:
Beaver Valley Power Station - Unit 1 Month:
August Year:
_2_02_3 ___ _
Municipality:
Shippingport Borough County:
Beaver NPDES Permit No.:
PA0025615 Outfall:
004 Watershed:
Ohio River Renewal application due 180 days prior to expiration.
This permit will expire on:
October 31, 2026 Chemical Names Dechlorination Nalco 7408 Dav gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons 1
0.0 2
0.0 3
0.0 4
27.0 5
0.0
-- f-*--
6 0.0 7
0.0 8
0.0 f--------------
9 0.0 f--------------
10 0.0 11 0.0 12 0.0 f----------
13 0.0 f---
14 0.0 15 0.0 f---
16 0.0 17 0.0 18 0.0 19 0.0 20 0.0 21 0.0 22 0.0 23 0.0 24 0.0 25 10.0 26 0.0 f--
f---------
27 0.0
-f-----
28 0.0 29 0.0 e----
30 0.0 31
~
Average 1.2 Maximum 27.0 I certify under penalty of law that this document was prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. See 18 Pa. C.S. § 4904 (relating to unsworn falsification).
Prepared By: James Harvey
Title:
Senior Nuclear Specialist License No.:....,,..,,,,,.,=..,,...,,--------------
Date:
9n/2023 lbs
ft e~~NT~~!~~E~
A~~O~
CTION 3800-FM-BCW0439 3/2014 SUPPLEMENTAL REPORT - CHEMICAL ADDITIVES USAGE Year:
2023 Facility Name:
Beaver Vallley Power Station Month:
.;.Au.;;;,,iig:.;;;u;.;;;s.;.t _______ _
NPDES Permit No.:
PA0025615 Outfall:
010 Municipality:
Shippingport Borough County: _B_e_a_v_e_r _____ _
Watershed:
Ohio River Renewal application due 180 days prior to expiration.
This permit will expire on:
October 31, 2026 Chemical Names Control-Brom CB-Biocide Dechlorination Corrosion lnhib.
70 Nalco H-150M NALCO 7408 NALCO CL-5 Dav gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons 1
0.0 0.0 10.69 0.0 2
0.0 0.0 10.69 0.0 I-
~
3 0.0 0.0 10.69 0.0 4
0.0 0.0 10.69 0.0 5
0.0 0.0 10.69 0.0 6
0.0 0.0 10.69 0.0 7
0.0 0.0 10.69 0.0
~
8 0.0 0.0 10.69 0.0
~
~
9 0.0 0.0 10.69 0.0
-~
L
~
10 0.0 0.066 10.69 0.066
~
f--
11 0.0 0.0 10.69 0.0 1-- --
12 0.0 0.0 10.69 0.0 1--
1-I-
13 0.0 0.0 10.69 0.0 14 0.0 0.0 10.69 0.0 f--
15 0.0 0.0 10.69 0.0
~
16 0.0
~
10.69 0.0
-- I-17 0.0 0.0 10.69 0.0 f-- --
18 0.0 0.0 10.69 0.0 I-
~
19 0.0 0.0 10.69 0.0
~
-- ~
f--
20 0.0 0.0 10.69 0.0
~ --
~ -
-- ~
21 0.0 0.0 10.69 0.0 1--
22 0.0 0.0 10.69 0.0
~ --
23 0.0 0.0 10.69 0.0 24 0.0 0.0 10.69 0.0 25 0.0 0.0 10.69 0.0 26 0.0 0.0 10.69 0.0 I- ---
27 0.0 0.0 10.69 0.0
--f--
28 0.0 0.0 10.69 0.0 L-29 0.0 0.0 10.69 0.0
~
30 0.0 0.0 10.69 0.0
~
31 0.0 0.0 10.69 0.0 1-- ---
Average 0.0 10.7 0.0 Maximum 0.1 10.7 0.1 I certify under penalty of law that this document was prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. See 18 Pa. C.S. § 4904 (relating to unswom falsification).
Prepared By: James Harvey License No.: -----------------
Title:
Senior Nuclear Specialist Date:
9n/2023 lbs
~
L 3800-FM-BCW0439 3/2014 (if ~!~!!~!o~ E~ A~~o~ cnoN SUPPLEMENTAL REPORT
- CHEMICAL ADDITIVES USAGE Facility Name:
Beaver Valley Power Station - Unit 1 Secondary Month:
August Year:
_2_02_3 ___ _
Municipality:
Shippingport Borough County:
Beaver NPDES Permit No.:
PA0025615 Outfall:
No Outfall Watershed:
Ohio River Renewal application due 180 days prior to expiration.
These feedwater additives are not typically discharged. They are reported to align with DEP guidance.
This permit will expire on:
October 31, 2026 Chemical Names Monoethanolamine Hydrazine PT7000 Dav gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons 1
6.0 0.0 2
6.0 0.0 f-----
3 6.0 0.0 4
6.0 1.0 5
6.0 0.0 6
6.0 0.0 7
6.0 0.0 8
6.0 0.0 9
6.0 0.0 10 6.0 0.0 11 6.0 1.0 12 6.0 0.0 13 6.0 0.0 14 7.0 0.0 15 7.0 0.0 16 6.0 0.0 17 6.0 0.0
-~
18 6.0 1.0 19 6.0 0.0 20 6.0 0.0 21 6.0 0.0 22 6.0 0.0 23 6.0 1.0 24 6.0 0.0 25 6.0 0.0 26 6.0 0.0 27 6.0 1.5 I-28 6.0 0.0 29 6.0 0.0 30 6.0 0.0 3 ~
0.0 Average 6.1 0.2 Maximum 7.0 1.5 I certify under penalty of law that this document was prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. See 18 Pa. C.S. § 4904 (relating to unswom falsification).
Prepared By:_J_im_H_a_rv_e... Y __________ _
Title:
Senior Nuclear Specialist License No.:
Date:
_g_n_/2_0_2_3 _____________ _
lbs
~
l 3800-FM-BCW0439 3/2014 t
PePA~ TM~!!~!O~
E~~~O~ CTION SUPPLEMENTAL REPORT - CHEMICAL ADDITIVES USAGE Facility Name:
Beaver Valley Power Station - Unit 2 Secondary Month:
August Year:
_2_0_23 ___ _
Municipality:
Shippingport Borough County:
Beaver NPDES Permit No.:
PA0025615 Outfall:
No Outfall Watershed:
Ohio River Renewal application due 180 days prior to expiration.
These feedwater additives are not typically discharged. They are reported to align with DEP guidance.
This permit will expire on:
October 31, 2026 Chemical Names Monoethanolamine Hydrazine PT7000 Dav gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons lbs gallons 1
6.0 0.0 2
6.0 1.0 3
6.0 1.0 4
6.0 0.0 5
6.0 0.0 6
6.0 0.0 7
6.0 0.0 8
6.0 0.0 9
7.0 0.0 10 7.0 0.0 11 7.0 0.0 12 7.0 0.0 13 7.0 0.0 14 7.0 0.0 15 7.0 0.0 16 7.0 0.0 17 7.0 0.0 18 7.0 1.0 19 7.0 0.0 20 7.0 0.0 21 6.0 1.0 22 6.0 1.0
- 23 6.0 0.0 24 6.0 0.0 25 6.0 0.0 26 6.0 0.0 27 6.0 0.0 28 6.0 0.0 29 6.0 0.0 30 6.0 0.0
~
31 6.0 0.0 Average 6.4 0.2 Maximum 7.0 1.0 I certify under penalty of law that this document was prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. See 18 Pa. C.S. § 4904 (relating to unsworn falsification).
Prepared By:_J_im_H_a_rv_e.&y __________ _
Title:
Senior Nuclear Specialist License No.:
Date:
..,,9""""17""'12,,..0,,..,2'""3 __________ _
lbs
L-23-208 ENCLOSURE C
e pennsylvanta J~ OEPARTMENTOFENVIRONMENTAL PROTECTION Facility Name:
BeavwValley Power-.,.,
Municipality:
Shlpplnaport Borough Watershed:
20-8 Laboratories:
TH!Amertca, BVPS Lab 3800-FM-BCW0435 l/2012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
~.: No.: :Ao.:;;;*->
6~~~11:
-:~1-23~----
Renewal application due 1lll..llll!I prior to expirati:fo"'"n~.-----
This permit will expire on:
~Oct=obe=~*~31~1~20~26~------
Flow pH TRC Free Available Temperature NH3-N Total Aluminum Total Chromium Tot.II Copper Total Iron Total lhrcury Total Zinc Hydrazine Nalco H150M Total PMnolica w...
De
- *0a,.;o' "'1-----,M-:,GO:=---+-:Q:,----,s'"'.uc---l-::Q:.-.....
+
-::0:.-C-h-lo_1~ __..
-:-_l-::Q:.-----::'F,--+-:Q::--r--1-=--+-:Q::--r--=
-+--,Q::--r--=-,,---+- Q::-1--'=-,---+--::cQ"T""----c..,..,----,1-::Q--r-1 __ --:--+-::Q""T"--.....,
--:--+-::Q,-,---,-----1-::Q""T"-----,--+
~Q--.---,---I 3
Sun 7/30/23 Mon 7131/23 Tue 8/1/23 Wed 812123 Thu 813123 Fri 8/4/23
~~/23
_ Sun_
~
Mon 8/7/23 Tue 8/8/23 Wed ~ ~3 Thu 811°'23 Fri 8/11/23
f---
Sa~
8/12/23 Sun 8/13/23 Mon
""ati4!23 Tue 8/15/23 Wed 8/16/23 Thu 8/17/23 Fri 8/18/23
~
- '¥1Q/23 Sun 8/20/23 Mon_
8/21/23 Tue 8122123 Wed __
Bl.?__312~
Thu 8/24/23 Fri 8/25/23 Sat 8/26/23 sun aID/23 Mon 8/28/23 Tue
- 8/2~ 3-Wed 8/30/23 Thu 8131/23 Fri Q/1/23
~~3 Daly Minimum (Cone.):
Dally Maximum (Cone):
Max AYg Weekly (Conc.):
Avg Monthly (Cone.):
GearnMrtc Meat (Cone.):
Max Avg WNldy (Load):
42.9,---='=-
8.1 42.81--
42.5, __
42.5, __
42.3 1-42.4, _
42.4 41.9 7.Q 41.4 _~
41.7 41.5 42.2 41.6 42.0 8.1 41.9 42.2 :_.=_
41.9 __ _
42.2 42.8 __
42.1 __
40.5 __ 8.1 40.1 __
41.0~ _
40.1, __
40.1 __
40.0 _
40.0 __
39.9 __
7.8 43.6 39.9 40.2 0.02 0.02 0.04 0.02 0.05
~
0.06
~
0.05 o.~-
~
0.02 0.06 1--
0.06 0.03 003 0.1 0.08 0 08 0.07 0.07 0.1 0.07 0.05 0.07 002 005 0.06 0.03 O.~
0.02
~
- 0.02 _
0.03 o.~t--
~
1-84.6 _~
83.9 _f---
85.1 _~
86.4. -~
83.6 _f---
85.1 _~
85.2_~
84 _f---
84*7 --
83.6 _r--
82.7 -
~
86,___,_ __
84.9 _~
85.1
~
84.6 _f---
85.8 _
~
86.5 _~
84.1 __
78.2 82.2 ~=-
87 -~
8:.~ -e---
87.8 =1----
90.1 _~
87 __
84.3 _1--
77 -~
80.2 _
79.4, __
7~ _
0.2Q 0.075 0.16 Q.3 -
< r-- *~-*~2-
-+--
+--~77~-+--+----+--+--*~**_75~ -+---1 0.1 90.1 0,3 0.07 89 0.3 0.05 84~.1-
--l--
+--
0.206
-e--- --
0.007,------1--
0.45 e--- -
o.~
r----
0.0088 0.13 0.31 o_oog1 o.se 1--
1---
0.005 0.1 3 0.0091 0.58 0.0081 0.58 0.0077 0.31 C
0.0002
- -Z- -
0.0002
- -1----
0.0002 0.0002 0.0002 0.00~ - 1---*
0.01
~
1-0.01 f-------
f----
0.034
-f-0.034 0.01 1----l--
-'a* *c,*3~*-~
1~
~
0.03 0.01
~
0.034 _
0.01
, 2.8 28 ~-
~
11 4
1H 0.07 T:=::=~; - 1i!i\\
~-----&-
- ~
5 1
- 7 2~!e -- -
- 1
- --1/4 3
127 0.07 03 3948 2
OalyMlnimum (load):
Ji.i - -- --
7 f'
~
11 oa1yuu1mum(Loact):.__4,_3,_.e_..__. ____,._..., _ _....__._..., _ _.3_,s_...,_.._ ___ _._.._ ___ _._,.__,_1.os._-_._-,.
1
_._ _____...,-.;*_._-:.,-:.,-:.,-:_11;..._i...;..i.-...;;4~...M 2
45
~
--3 1Q8 0.07 I certify under penalty of 111w that 1h11 document ** prepared under my direction or aupervlslon In aooorclanoe with
- sysll!lm designed 10 auu,. that quallfted peraonnel gathw and evaluate the Information submitted. Baaed on my
~of,_ pnon or peraons ~
nwiage IMI system or IKIN pe,aons dnctly rnpon9'blefor gathemg 1he lnformdon, fMo nfom.tlon.. brnlftsd Is, 10 the ti.at of my knowledge and bellef, true, accums and complete. I.,,._,.
.,_._... agnlflcantpaiallnfor.. bmllllngfalaeinformatlon,lncludlngh~oft'IMandtrnprtaonmentforknowlngvlolatlons. SN18Pa.C.~.§-4CI0<4(Nllallng10unN1:1rnfat.lflcation).
Prepared By:
James Harvey Titie:
Senior Nuclear Specialist License No.:~==---------------
Date:
-"911=3/20=2"'3'--------------
Facility Name:
Municipality:
Shippingport Borough Watershed:
Laboratories:
TNIAmerlcaz BVPS I.ab 3800-FM-BC'M>-435 312012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
Month:
8 <-*->
Year.
2023 Permit No.: PA0025615 Outfall:
-=00""2;=-----
Renewal application due ll!!J!lltl prior to expiration.
This perm1t.,.;11 expire on:
-'a-,=='-3""1""1"20"'26=-------
~Fl
- w +-=-r-------+-:------+-::--r--~--+.,,..-,---~-+-,:-r---~-----+-::-r--~------1 0
MGO Q
Q Q
Q Q
Q Q
Q Q
Q Q
~
Sun7/30/23-f----
Mon 7131123
__ ___Iu~_ ~1/23 -
Wed 8/2123 Thu
~3 Fri 814123
- -- Sal=
~512!_ __
2
~~/23 Mon 817/23 0.046
~~8123 - t---
Wed 8/Q/23 r---
Thu-M 0/23
--- Fri 8111123 Sat -
8/12123-3 Sun - tl/13123 --
1---
e-------1--
1--
i---
---i---
--1---- -I---
~
-f---
1-f-----
f-----
- f--- f-----
-I--
-f--
f---
f---
I---
--1--
-f---
f---
Mo;;- 8/14/23 o.oo,
~
Tue 8/15/23 w8d e116t23
~
8117123 --
Fri 8/18123
-- Sa1 - 8/1Q/23 --
4 Sun 8/20/23
---Mon-8/21123 ~046
___ T~
~2123 __ _
Wed 8/23/23 Thu-8124/23 --
Fri 8125123 I-Sat 8/2fl/23 Sun-8/27/23
~
8128123 11-70.704~.c-,l--l--
Tue 8129/23 Wed-8130/23 Thu 8/31/23 Fri 9/1/23 Sot 012123 Daly Minimum (Cone.).
I-- --- -- --
-I--
1------+-
+--- --+--<--- - -
- ---~ --
-+--
1----- -
--f--------
f-----
1------l--l-- -- --* ---,_ --
Daly Maximum (Cone):
MIDI A"'D Weekly (Cono.):
- -- -f--- 1------+-- l-----j-
____, __ ---+---+--- -
AYgMonHy(Conc.): _
GeorneericMNl'l(Cono.);
1------- -
!- -+-
Max Avg Weekly (Lom): 1--~*~**~**~ +--+-----l AYgMonlhly(Laad): ~
I- - ~ - - - -
-f------*- o--
TolllMonHy(Load):
0.1M t-----+-
+-------+--- -
1- - - - -
1----- - - - ~
r---- - -
-~
f------
- f---
--1--
~
1-
-+----
f---
f--
OalyMlnffllffl(La.d}; --~.~.* ~
.. ~+---+--
i--
-t-OalyMaximum(Load):.__.0,..0_.4"._.__. ____.__. ____.__. ____.__. ____.__. ____,.__. ____ -_.-_.. f--__
-:,-:,-:,-:,-:i~_ -.._-___ :jt:j~:::.:.:::-.._f--_t::::::::t::~:-----------1----..1.-1----.1 I cerlfy under ~
d 111w flat Iii. document was prepared under my dncllorl or a1peNlalon In aooordance.... syaillm dNlgned to....,. lhat qualfted pereonnel galhe,' and..,...._ th4I lnfomwion 1Ubm1119d. Sued on my lnquwy dlte penon <<peraons who n.,.,- Syalffl orllONperaonsclrdy rwponal:ir.fcw-gaf,emgt. lnformallon, h lnformdon aibrnln.d la, tohbNtdmy knowledga and beW, lnNo, ~
and oompletll. I_,,.,..
thlll.......... lllcant~forM)fl'lllllng...._lnformllllon,lnoludlng.. ~dhandmpriaanrnantforknowlng'llaldorla. S..18P.C.S.§-1CI04(Nldngtounaanfalsllloallon).
Prepared By:
James Harvey Trtle:
Senior Nuclear Specialist License No.=------------------
Date:
-'9"=12.a0..
2 __ 3 _____________ _
g pennsylvanfa J~ DEPARTMENT OF ENVIRONMENTAL "88 PROTECTION Facility Name:
Bew Valley p....., StallOII Municipality:
Shippingport Borough Watershed:
Laboratories:
TNIAmerlca. BVPS Lab ll00-FM-BCWG4315 3/2012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
Beaver Month:
8 (Nloct nu-)
Year.
2023 Permit No.: PA0025615 Outfall:
"'00"3="'° ___ _
Renewal application due 1!!!LI!DI prior to expiration.
This pennlt.,,;11 expire on:
-'Octobe=='-r 3:c1e<r.:2026='--------
"t----.:Fl;;;: w;;;--+-;;--r-N-H-;3-;-;N;----'l,;T,--otar-lA-lu-:m=l*n*_m---,l,;,--Torta-1-M-:*="'*"'Y_+-;;--rHy-d_,.-:*=lno:;--r;,Nr*-lc_* *H=15:.0-M-h.T----h.T----+-,;,r----+-,;,r----+;_,----+.,,..,r----+.,,...,r----+.,,...,r---- =---
- ---11 tO MOO Q
S.U Q
m;,l Q
11'9'\\.
Q n¢ Q
Q Q
Q Q
0 Q
Q Q
Q Sun 7130/23 M~ 7/31/23 Tue _ ~123 Wed 8/2/23 Thu 8/3/23 Fri 8/4/23
~
8/5/23 Sun 8/6/23 M~~/23 Tl.ff!
8/8123 w~ ~ B/Q/23 ~3 Thu-
~0/23 0.135 Fri --8/11/23 --
Set 8/12/23 5u;- ~13123 Mon _ ~/23 Tue 8/15/23 0.134 Wed 8/Hl/23 Thu
~17/23 --
--t--
4 I-
~
e---
Fn 8/18/23 --
Sat 8/10/2~
8/20/23 Mon 8/21/23 Tua 8/22/23 Wad --=~3/23 Thu 8/24/23 Fn 8/25/23 Sat 8126/23 s~ ----W7/23 Mon 8/28/23 Tue 8/29/23 Wed 8/30/23 Thu - ~/23 Fn Q/1/23 Sat 0/2/23 OalyMlnfflum(Cc:s,c,):
Daly Maximum (Cone):
M,oc A119 W..., (Cone.):
A.vg MonHy (Cone.): 1------
GeomNtc M- (Conc.): i---------
MaxAvgWeekly(LOl!d):
~
9 A\\9 Monthly (Loed):
0.137 Total Mont,ly (Loed): ~
Dally MflfflUffl (Load): ~
O~ Maximum (Load): ~
1--
0.13
f-0.13 0.0002 0.034 0.34 0.0002 0.034
~
0.0002 0.03 0.24 0.0~
O:'!!__
0.4 0.0002 0.3 0.0002 8
0.007
'< -~
-+-
-J----
--o.-, - - <
o.ooor _
0.4 0.0002 I a.try undar peNly d larriJr, l\\at fits document WM snpawd undw my dncton ar ~
In aooordanoe wtlh
- syam dNlgned to_,,. 11111 qualltad penonlMI gdler and eY11k1a1a IMl lnfonnallon albrritlld. BaNd on my lnqwy dh penon arpar9Clft9who ~
IMI syaam art,oeeper110nadnolly'tNp01111Nfa'galhenng IMl lnfarmdon, IMI flformalon 1Ubmit19d la, to IMlbNtofmyknowlldge,and bllef, WI!, accuraaand oomplaa. I am_.
hlt.._... lignll'antpenll!INfaraubmlllngt.lN lnfonnallon, lndudlng llepoul)atydf'neand ~mentfarknowlng Ylolallon*. S.. 18P*. C.S. § 4004 (Nllllng toun-.nfalalflcdon).
Prepared By:
James Harvey Tille:
Senior Nuclear Specialist License No.:
Date:
""917=120=2"'3 _____________ _
1--
1- - - -
f------
f------
1-----
1--
I----
f------
f------
1--
f------
I-1--
~
r--- -
--+-
+-----I 1--
f---
e pennsylvania J,,,aJ/B DEPARTMENT Of ENVIRONMENTAL
'a:t!!!!I PROTECTION FaciityName:
S.-rYalley P-r Slallon M.Jnicipality:
Shlpplnapo,t Borough Watershed:
20-8 Laboratories:
TutAmertca, BVPS Lab Flow pH MGO Q
S.U.
Sun 7/30/23,,_ __ _,__ +-_
Q Mon _ J/31/23 ll------1--
~-----l ll-----!-
T'-'u"-e 8/1/23 0.0 Wed 8/2
=-=/7.=3_1,__
o~.o'-_,___,__
~
813123 Fri Ssl 8/4/23 11--"1.C'C0 _ _.____,__---"7." -1-----'--l Sun Mon Tue 1- -
Wed_
Thu Fri Sst --g;;;;
8/5/23 0.0 816/23 anm 818123 819/23 0.0 0.0 0.0 8/10/23 o.. o._-'----'---
,~
~
8/12/23 0.0 8/1312,::3c11-_
0ec.O"------'--- '-- -
3100-FM-8CW0436 ll2012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
=No.: -kc:=;-1
=II:
-=::=:2=.3 ___ _
Renewal application due~ prior to expiration.
This permltYAII expire on:
..:Ocaa==lobe=,._* 3a.1a..r.::20aa26==--------
TRC Fre* Avallabi.
Chlorine Temperaturw Total Aluminum Total Chromium Tot.Ill Copper 1
maA.
Q Q
'f Q
Q Q
moll 0.02 0.03 00.1 1.1 -
--+--
1---
1--
1-- --
Total M*rcury Total Zinc Q
Q
-l----J- ----+---l 0.0002
~
Mof! _
8114/23 0.0 Tue 8/15/23 0.0 Wed
~
1e123
...Q-~ -
L-Thu-_ 8/= 11~,2=3_._~
o~.o.___,____,_
Ftl __ 8:::.l;.o 1812=3-1--'o"".o.__,
s.,
=81~1*~12.. 3~.__
o~.o'--1--- l-----'
Sun 8/20123 Mon Tue 8/21/23 0.0 I---
--+-- l----
--1---
i -
Wed Thu L-Fri I~
~~
--~on Tue 8122/23 8123/23 8/24/23 8125/23 8/26123 8/27/2.3 8/28123 8/20/23 0.0 0.0 0.0 0.0 0.0 0.0
~
Wed Th~
Fri 8/3~ l---
8131/23 0/1/23
-- ~Sat 0/2/23 Daty MlnlrNJm (Cane.):
Daly M...,,_,m (Cone~
MaxA"'9WNl,Jy(Canc.):
A"'SI Mont,ty (Cane.):
Geom.Mc MMrl (Cane.):
MaxA"'9W.,,J,jy(lo.t):
~I---
A"'9Monttly(lo.:I):
0.1 Ta!Monlhty(lo.:I):
1.5 O-,,M-..(1.ood)c 7.5 7.4 7.5 1--
- --~
~
~
0.05 1----1--
-'o~.o.. 5._--+-
+--
"-eu 0.2 -
0.0035 0.02 0.03 81.1 0.2 0.0035 0.05 0.05 90.1 1.1 0.005 0.05 0.05 00 1.1 0.005 0.04 0.04 es.e 0.7 0.0043 0.2 0.3 0.04 0.2 0.2 1-1--
5 1
1~
0.03 0.9 0.2 0.2 o.a 0.01 DalyMIUClnutl(Load):
-.2-0.3 9
0.04 I ciertfy llndel" penaly rA law""' Illa itocum.rt wn ~
Lim" my cl,.clDn o, ~
In aooonMnce..,_ a s)'lllm dNlc,,ed lo..... Ital qu.ar.d per90l'lnM ~and........ h lnbmatlon auhmlttld. Bned on my nqwJof h pllf'Nfl o,penona Wliho ~
h 8yaMI orlloM J)9nOl'II clr'IICty,..,,,...tor gd'..tng.,. lnformdan, t,e Worma9on aubmffled II, lo t,e bMtofmylcnowledgeand bellf,.,_.., aocurllleand ~- I am.-.
lhat.,_._,.aignlllcMtpena11teakw~~lnb'mllllon.lncludnghpoNl)lltyofftneand~ttorknowlng\\4oldon1. S..18Pa. C.S. §4004(1Wllng1Dunawomflillillk:alon).
Prepared By:
James Harvey Titte:
Senior Nuclear Specialist License No.:
Date:
0111=3/20="'2"'3 _____________ _
0.0002 0.0002 0.0002 0.0002 0.0002 0.002 0.001 0.04 0.0008 0.002 Q
Q Q
Q - --~ C--
I----- -
g pennsylvanfa J-OEPAATMENT OF ENVIOONMEHTAL PROTECTION Facility Name:
BMver Valley Power Station Municipality:
ShlpplnpPort Borough Watershed:
20-8 Laboratories:
THIAmertca, BVPS Lab Flow 3IOO-FM.sc'MM35 3/2012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
~~r:~ No.: -:-A-oc:;:;;*-l 6~;~11:
~:os~
0-23~----
Renewal application due llJLI!ln prior to expira"uo"'"n~.-----
This permit v,;11 expire on:
~Oct=obe=r~3~1~, =-20"2"6 ______ _
Day ot!.Mlt--~Mi~:;;--+~0CT----+-::0CT----t-::0CT----t-::0CT----+-:0::.----+-:0::.----+-:0;;.----+0;;-i----+~0-.------,l--::0-r----l--::0CT----+-::0CT----+-::0,.-,-----jh,0.----~I
---f--
___s.,_n_
7/30/23 Mon 7/31/23 Tue 811/23 Wed 812123 Thu 8/3123
-- --f--
Fri 8!4/23 Sat 815123 Sun 816/23 Mon 8/7/23
-!: =:
Thu 8/10/23 ---
Fri 8/11/23 Sat 8/12/23 Sun 8/13/23 Mon 8/14/23 0.016 Tue 8/15/23 Wed 8/16/23 T~
_8/17/23 f--
Fri 8/18/23
~
8/19/23 Sun 8120/23 Mon 8/21/23 0.016 Tue 8122123 Wed 8123/23 Thu 8/24/23 Fri 8125/23 Sat 8/26123
-- ~
Sun 8127/23 Mon 8128123 ~
Tue 8129/23 I-f-- --
Wed 8130123
~
8131/23 Fri 0/1/23 I-Sat Q/2/23 Dally MlnlmUm {Cone.):
Daly Maximum (Cone):
Max AYII Weekly (Cono.):
1----
A"',1Monllty(Cono.):
--(Cono.),
Mait:AvgWNkly(toad):
0.0115
"-"9 Ma,llfr (\\.old}:
0.0 11S ToWMonl'lfy(l..oad):
0.084 Daly Minimum (Load):
0.018 Dally M-..,, (Lood),
0.018 I certify under penally cf llli# flat HI document** l)Npllf9d under my clNctlon or supervlaton In aooordanoe Mt,
- systam dNlgrwd to ltMUN that qualfflllcl per10nnlll,..._ and *valu* lhe tnforrndon...,.bmlttld, Baled on my lnqWry dfle peraon or,-.onswhO...,.._ the syatlm or ltM>N pan,o,11 clNc:fy,..,,on..,..forgallertng 1M Information, f1e lnfonnaton tubmltlld la, to the bat dmy ~and bellef, INII, aooumitand oomplet9. I am--~
11athre.. lllgnllklantp,na11NfortubmltllngftllNll'lfcrmdon,lndudlngfMlpoulbltydtlneaidlmprteonmentfotMOMng>Aioldol'I.. S..18Pa.C.S.§4SKM(Nldngtounaiworr,fahll'lcdon~
Prepared By:
James Harvey Tille:
Senior Nuclear Specialist License No.:-===,---------------
Date:
.:911=/20=2::3 _____________ _
--f--
f---
f------
-+-- +--- - --
--f--
1---
+-
+-----+-
+-----+-
--l -----
-r----
--jf--t--- -- --
,_ DEPARTMENT OF ENVIRONMENTAL PIIOTECT!ON Facility Name:
BeawrVolloy P_, Stollon Municipality:
Shlpplnapoot llorouph Watershed:
20-B Laboratories:
TNIAmerlca, BVPS Lob Flow pH 3IOG-Fll-8C'M435 3/2012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
TRC FrH Available Chlorh,.
Month:
L<.....,noomw)
Year:
2023 Permit No.: PA0025615 Outfall:
..:::001='-----
Renewal application due 1ll!J!ll!I prior to expiration.
This permit will expire on:
~Oct_obo r 3~1~*-20~26~------
Tem.,.ratul'8 Nalco H150M Week Dav Oata~l--:Mioo:;;--+-;aCT-
-:s;-;u-,-_-+-::aCT--::::,--l-::a,-,--::::,--l-::a,-,----..,,--t-,a:,---::::::--+-:a:.----+-:a:.----+-:aa.----+-:aa.-- --+:;;:a-r---~l-::a-r---~l-::a-r---~r-::a-r----4-a,,..-,----
-1 Sun 7130/23 -
Mon 7/31/23 -
Tue 8/1/23
-f---
Wed
- 8/2~
Thu 8/3123 Fri 8/4/23 f-
--- f-f-
f-Sat 8/5/23
~
>--Sun sm/23 Mon Bfl/23 f---
--f--
f--
Tue 8/8/23 Wed
- a.,g123 f-- Thu 8/10/23
-f--
f----
f-------Fri 8/11123
- ~
8/12/23 3 ~n 8113123 i----Mon 8/14/23 -
-f-- -
--f--
~e 8/15/23 1----Wed 8/16/23
-- f----
f----
-f----
t-----
Thu 8/17/23 f--
8/18123 -
Fri
~ 8/10/23
--. ~
n 8/20/23 -
Mon 8/21/23 f---
f-
-f-- ---
-t---
~
8/22/23 -
,___wed 8/23/23 -
~ 8/24/23 Fri 8/25/23 f----
-f----
--f--
I- -Sat 8/20/23 - -
Sun 8/27/23 Mon 8128/23
- f--
~
8J2g/23 -
Wed 8/30/23 f--
t--
Thu 8/31/23 Fri Q/1/23 --
~
W2/23 DIiiy MJnlmum (Cone.):
Daly Malrnum (Cone):
Max Avg WNldy (Cone.):
--1--
r----
A"9 Monf'lly (Cone.):
GeamalcM..i (Cone.):
-~ ---1--
--1---
Max A"9 WM/t!Jy (load):
Av; Monllly (load):
i------------
f---
Total Monf'lly (Lolld):
Dally Minimum (Load):
f---
f----
OalfyMaimum(Load): _____________________________,_ ___ _._.._ ___ _._-_.f-
____..,__..__ ___..__.__ ___ _.__._ ___ _.,~_._ ___.,,1,,_._ ___ _., _____
..1.,_&... ___.II I QWtfy uncw penally t:I._ flat Illa doc:uma'lt,... ~
undar my c:lrwclon or~
In aooon:tanoe wilt* systam dnlgned to.....,,. flat qullllftad penonnel gather' and.......... IMi infonTlllllon subrritl9d. Bned on my inqulrydh penon orpenonswho rMnagalMi syswn orh>N penon* dncllyfNPCl"... for~ the lnfonndon, h informllllon...tmtl9d Is, to 1Mi bNt dmy ~and bellef, Nt, aocu,_and oompla. I 11m._..
thal:..... algnll'tcanl,,.,,...foraubmltlngflmlnformalon,lnoludinglhepoulllltydlflMandimpMonrMntforknowlngvkMtlon*. S*1SPa.C.S.§-400'4(1Wt!ngtounawornf..mc.tion).
Prepared By:
James Harvey Tolle:
Senior Nuclear Specialist License No.: _________________ _
Date:
.. 917
....... /20=2'-'3 _____________ _
G' pennsylvania J~ OEPARTMENTOFENVIRONMENTAL
'111:1!!!1 PROTECTION Facility Name:
Buvw Valley p-, Station Municipality:
Watershed:
Laboratories:
Shippingport Borouph TNIAmorlca. BVPS Lab Parameter Stngo Flow m:::r--all:!'JII~
MGO Q
1 Sun Mon
=rue
~d Thu Fri
___5!!.
Sun Mon Tuo
-- -----WSd Thu Fri Sol 7/30/23 7/31/23 8/1/23 4.32 812123 -
8/31~
8/4/23 815I~
11111/23 8/7/23 818/23 5.04 8111/23 8/10/23 8/11/23 8/12/23 8/13/23 8/14/23 3.6 8/15/23 8/16/23 -
8/17/23 8/18/23 8/1Q/23 8/20/23 8/21/23 _
2.88 8/22/23 8/23123 8/24/23 8/25/23 8/26/23 8/27/23 8/28/23 8J2g/2J 8/30/23 3.0 8/31/23 --
0/1/23 9/2/23 --
pH SU 7.3 Q
7.7 Ja00-Flf-BCW04315 J/2012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
TRC Free Available Chlorine 0.03 Q
Month:
.!,_1.-.,u-1 Year:
2023 P81llllt No.: PA0025615 Outfall:
-=0"10.-'-----
Renewal application due 1l!l..!IID prior to expiration.
This p81llllt will expire on:
... Octobe==--3~1""1 '-20.. 2& ________ _
Temperatu,.
Total Mercury Q
81.6 C
82.5 83.1 82.7 84 83.1 80.5 81.1 80.6 "
80.2 80.2 82.2 82.9 82.8 83 C
83.1 83.3 82.4 80.4 80 83.1 83.1 83.6 82.7 83.4 83.6 83.4 78.9 80.1 80.1 80 0.0002 0.0002 0.0002 Nalco H150M Q
DlllyMlnmJm(Conc.): o----+-
-t--
=
-+-
-t-----+-
-t-----+--i 7.3 0.02 0.02 78.9 0.0002 0.01 0.08 8_4 __
Daly Maximum (Cone):
Max A"ll WNldy (Cone.):
A"ll MonHy (Cone.):
o.om.tc M..-, (Conc.):
MD A"9 W..ty (Lmd):
A"'IJMonthly(Load):
Total Monthly (Lo.t):
Daly MlnlmUm (Leed):
C C
o.oa 0.08 1
33 0.8 0.0002 8_3 ___
0.0002 0.0002 82 __
0.008 C
o.ooa
---. --o.-, -
0.007 Q
Q Q
DalyMmdmum(lood),.._..,__,,_.,_..._ ___ _.,_..,_ ____ _.,_..._ ____ _.,_..._ ___ _.,..;._....;_,;..,....,_.i., ___....,_.i., ___ _._-"-___ _._,._ ___...J._..l. ____._..1, ____,__,_ ____,__,_ ___..J.._..I. ___..J 2
0.008 I c.rWy und9r.,.,.ity d a-hal:.. docum..t:... pr-r:-9d undlr my dlreclon or~
In aooordanoe... sysllm dHlgned ID...,,. hat qu.-.:t pw90nnal gat_. and......... f,e lnfonnllllon aibmltllld. B*Md on my lnqulrydh pwlOn <<...-*who-ave... s)'ltlmorh>Npa,9e1r1sdk9Clyr-,,onal:,lefor~1Mlnfonndon. hinrom.ton ltbnltlldls, lolMlbNldmyknowledpandballaf,WII, aocurnanc1oomp1911. I.,,......
lhatlhere.. llgnfflcanll)Wlalllnfor.,bmltllng falN lnformalon, lndudlng.._ posd,ltyofh and lmptaonmenlfor knowing~-. SN 18 Pa. C.S. § 41CM (l'Ntlng to unswam falslflcatlon).
Prepared By:
James Harvey TIiie:
Senior Nuclear Specialist License No.:
Date:
"'917=120=2"'3 _____________ _
~
~
==Clf'EN\\IJRONMENTAI.
Facility Name:
Beawr Valley Power Station Municipality:
Shippingport Borough Watershed:
Laboratories:
T-merlca. BVPS Lab w*
Dav Date Su, 7/30/23 Mon 7/31/23 Tue 8/1/23 Wed 8/2123 Thu 8/3/23 Fri 8/4/23 Set 8/5/23 Sun 816/23 Mon Bn/23 Tue 8/8/23 Wed 8/11/23 Thu 8/10/23 Fri -
~
Sat 8/12/23 Sun 8/13123
~
8/14/23 T~ 8/15/23 Wed 8/16/23
- ~
8/17/23 Fri 8/18123
~8/19123
~
8120f23 Mon 8/21/23 Flow Total lhrcury MGO Q
0.004 0.004 0.004 0.0002 f- 0.004 0.0002
--f--
--f--*
Tue 8/22/23 Wed 8/23/23 H-----+-
-t---
Q 3300-FM-BCW0435 3'2012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County: -*
Month:
Lc-,um... )
Year:
2023 Permit No.: PA0025615 Outfall:
-=0"11=----
Renewal application due ~
prior to expiration.
This permit will expire on:
~Oct~obe=~* 3~1.,~20~2~6 ______ _
Q Q
Q Q
Q
--f---
-f---
-f---
f-----
Thu 8/24/23 t--+----t--+---
-f-----
f--
Fri 8/25/23 Sat 8/26/23 Sun 8127/23 Mon 8/28/23 t--+---- -
- ---t--+----t---+--
Tue 8/29/23 Wed 8'30/23 Thu 8131/23 Fri 0/1/23 Sat 0/2/23 Daly Minimum (Cono.):
0.0002 Dally Maximum (Cone) :
0.0002 Max Avg Weady (Cone. )
0.0002 o.0002 A\\ID Momhty (Cono.~
~M-,(Conc.):
MllxA"'(IWeehly{Load):
0.004 0.000007 A.,"°"""Y(l.ood) 0.004 0,000007
1 T"'"'Monf>ly(Lood)c 0.016 0.0002 Daily Minim.Im (Load):
0.004 0.000007 Daly Mamum (Load):
0.004 0.000007 I oertlfy under penalty d law IMrC l'lla document wn ~
under my dnctlon or aupervlalm In IIOOOfdance with
- aynlffl dnlgned lo aMtJN lht q.,lifled personnel gather and evlute the lnfonnllon aubmlhd. Based on my lnquwydlle per90n or ptnOn*~~ lhe ayelam orfloN pereor, drdy rwponatileb'gtt.tng1he infonMlton, h informdon SIJbrnitlad la, ID h btdmy ~
nd blf, tru., ocu'1III and oornpel. I rn.,..
httti..-signlficntpn119foraubrnltllngfIM~.lndudn(lhpoulbilltydflne ndlmpMOMWltforknowlngvlaltlorla. S..18P.C.S.§4GCM(rwldng1DunS'M>l'nftalflctla,,).
Prepared By:
James Harvey rrtte:
Senior Nuclear Specialist License No.:
Date:
"'9'7=120=2"'3 _____________ _
Q Q
Q Q
Q Q
Q 1--
f----
-f-----
f------
~
t---
~
pennsylvanta
~
~OFENVIRONMEHTAL Facility Name:
Bew Valley P-Station Municipality:
Shippingport Bon,ugh Watershed:
20-S Laboratories:
TNIAmerlca, BVPS Lab 3800-FM-BCWM.35 3/2012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
- a....,
Month:
.!._ <-...-)
Year:
2023 Permit No.: PA0025615 Outfall:
"'0~12~----
Renewal application due 1lll..!!ID prior to expiration.
This permit will expire on:
_,Octobe=='-' 3;:;.1:.i.1=20==26=-------
Fl~
pH Total Cadmium Total Coppor Tota'. Zinc o ~ 't-..
M;;;GO;;-+-;;a,-,s;;u,---lna,--=.
..,.,-,-;;a,--=.
_,,--,l-;;a,--::,,,.,,_:::.-+-;;a.r----l--;:a.r----l--;:a.r----t-;a.r----+.a.r----+a;;-r----+a;:;-,----+a;:;-,----+-a::--r----+-0::-r----~
Sun 7/30/23 Mon 7/31123 Tue 8/1/23 Wed 8/2/23 Thu 8/3123 Fri 8/4/23 Set 8/5/23 Sun 8/&123 Mon 8/7123 Tue 8/8123
~ ~
Thu 8/10/23 00
-f-------
- ~8/11/23 Sal 811212a 3 -o-~Su~ n~+-'8/~1~312
= 3-ll--
>--f-------
Mon 8/14/23 f- - -
Tue 8/15/23 Wed 8/16/23 r-ThtJ - 8117123 -
Fri 8/18/23
-~
8/10/23 Sun 8/20/23 Mon 8121/23 Tue 8/22123 Wed 8/23123 Thu 8/24/23 Fri 8/25123 Set 8/26/23 Sun 8/27/23 Mon 8/28/23 Tue 8/2Q/23 Wed 8/30/23 Thu 8/31/23 Fri 0/1/23 Set Q/2123 OllllyMirmlum (Cone.):
Dtllly Maximum (Cone):
Max AYD Weekly (Cone.):
Avg Monlhly (Cone.):
GeomN1c M..-. (Conc-t-MaxA"'II WNkly (Load):
A\\IQ Monthly (Load):
Tola! Monlhty (Load):
,-f--
0.0
- f-- f---
f-------
- ~ ~
Daly Minimum {Load):
.-->--f-
- ---f-f-
t--+----- *-
1- -
1-DllllyMaximum (l.oad):. -__
- ..,._.,_,._ _____,._ _____,._ _____,._ ___ _.,_.._ ___....l_.i.. ___....l_.i.. ___..,...,.... _____._... ____ 1-..1,,----.,_..1, ____
.,_..1, ____ l.,...l, ____ -.... _-..l,~ ____
-J I cerlfy under penalty d t.w M lhla c1ooumw1I._. ~
undw my chctlon or IUpervialon In aooordenoe with aymm dnigned ID nsure lhat: qualllled pwaonn.i gltMr and....... the lnformdon IUbmltted. Baaed on my Inquiry d fie F)9raon or pawana.tlo nwiaga l'9 aystlm or thOH panons dncly,-ponslbfe for gathering lhe lnfomwlon, lhe lnfonndon Mlbmlllild la, b lhe ti.st cl my knowladg9 and belef, tnM, accunM and complnl. I.,, ~
._...... signillcantpenallet.forsubmltlngW..lnbmdon,lncludlnglhepoul,atyclflMandlmprlsonmentforknowlngWllatlons. SN18Pa.C.S.§4G04(NlallnglounSWC1rnfalslllcdon).
Prepared By:
James Harvey Tttle:
Senior Nuclear Specialist License No.:
Date:
""'911=3/20=-=23,,..--------------
G' pennsylvania J~ DEPARTMENTOFENVJRONMENTAL al!!!!I PROTECTION Facility Name:
Beaver Valley Power Sttlon Municipality:
Shippingport Borough Watershed:
20-8 Laboratories: -
Flow pH 1
1 t
MGO Q
s.u 1
Sun 7/30123 Mon 7/31/23 Tue 8/1/23 Wed 8/2/23 Thu 8/3/23 Fri 814/23 Sat 8/5/23 -
2 Sun 8/6/23 Mon Bn/23 Tue 8/8/23 Wed 8/9/23 0.002 7.8 Thu 8/10/23 Fri 8/11/23 Sat 8/12/23 3
Sun 8/13123 Mon 8/14/23 Tue 8/15/23 0.002 7.8 Wed 8/16/23 Thu 8/17/23 Fri 8/18/23 --
Sat -
8/1Q/23 4
Sun 8/20/23 Mon 8/21/23 Tue 8/22/23 Wed 8/23/23 Thu 8/24/23 Fri 8/25/23 Sal 8/26/23
- 5-- Sun 8/27/23 Mon 8/28/23 Tue 8/29/23 Wed 8/30/23 Thu 8/31/23 Fri 9/1/23 Set 9/2/23 Dally Minimum (Cone.):
7.8 Daly Maximum (Cone):
7.8 Max A¥g Weekly (Cone.): --
Avg Monthly (Cone.):
GeairnfficMeat (Cone.):
Max Avg Weekly (Load):
0.002 Avg Monthly (load):
0.002 TollllMonlhly(t.Olld):
0.004 DallyMlnlroom (Load):
0.002 Dllily Maximum (Load):
0.002 38o<M=M-BCW0435 3/2012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
Beaver Month:
_8_(""""",u_)
Year:
2023 Permit No.: PA0025615 Outfall:
"'0'"13=""----
Renewal application due~ prior to expiration.
This permit v,11 expire on:
-'Oct=o""bo"""'r 3"-1"'1"20"'2""6 ______ _
TotalCop~r 1
Q -
Q Q
Q Q
Q f-0.0083
--~
~
0.0044 f-0.0044 0.0083 0.0083 0.0084 0.0001 0.0001 0.003 0.00007 0.0001 I certify under penalty d law that this document wn ~
undlir my clrwctlon or auptll"\\'lslon In accordance with system designed to nure that qualllled personnel gather and ewh.l* the Information submittBd. Based on my Inquiry d the penon or pen,ona who manage h system or thoee perw:,na dncty rnpon.i:,i. for gathering the Information, the Information subrnitled la, b lhe beat olrny knowledge and belief, true, accurate and complete. I am...,.re thatlhereare signll'lc.-rt penalties for submlttlngftw Information, lncudlng lhepont,llltydflnto and lmpnaonrnentforknowfng lriolationa. See 18 Pa. C.S. §~(relating tounawam falsification)
Prepared By:
James Harvey TiUe:
Senior Nuclear Specialist License No.:
Date:
-=9f7=12'"'0"'2.,..3 _____________ _
Q Q
Q Q
Q Q
Q
-~
~
pennsylvania JIOO-FM..SCW0435 3/2012
~
==OFENVIRONMENTAL SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING Facility Name:
a.wva11eyp_,-.,,,
Municipality:
Shippingport Borough County:
a.-
Watershed:
Laboratories:
TfftAmertca, BVPS Lab w
Ot 1
Sun 7130/23 Mo!:!__ ~
/23 Tu~~/23 Flow MGO Wed__
8/2/23 ~7 Thu_
- 8/3/23 Fl_!__
8/4/23
~
_ 8/5/23
_ 2_
~
_ 8/fl/23 M~ Bn/23 Tue 818/23
_____Q.007 Wed_ - 819/23 Thu 8/10/23 Fri 8/11/23 Set=
8112/23
_ 3_
Sun_ ~3/23 M~
8/14/2~ __
Tu~ 8/15/23 w~ 8/1e123 Thu 8/17/23 Fri_
8/18123 0.009 Sat_
8/1Q/2~ _
4 Su___!!_____
8/20/23 M~ 8121/23
__ __!_ue __
8/22/23 Wed
_ 8/2.3/23 ------0:00S T~ 8/24/23
..£!:!.__
8/25123 Sat B12e123 Sun __
"ii27/23 M..£!!...._ - 8/28123 0.007 Tue _
812G/23 ~
Wed_
8/30/23 Thu _
8/31/23 1_
F__!!___ _ 0/1/23 Sat W2/23 DIiiy M~m (Cano.):
0 pH RI SU 6.5 0
TSS RI _,
4.0 OllandGrHH RI Q
,~
4.0 1-6,9 __ < __._.o_
1......:!.._,_
4.~
1--
6.8_
4.0 5.0 1---
1---
1-1-
~
6 3--=-1_ C 4.Q 5 1 _
1-- ~
LI Month:
8 Year.
2023 Permit No.: PA0025615 Outfall:
-=1~01=-----
Renewal application due 1UJ!1n prior to expiration.
This permit \\\\ill expire on:
~0ct=tobor=~J_1~,_20~26~------
NH3-N Hydrazln.
RI RI Q
Q Q
~ -
I-I-
J--
1--
-f--------
I-Daly Maim.nn (Cono)*
1----------
Max Avv Weekly (Cone.):
- ~**c____--4_:_+
1, ~ __
J.J__
~
- I~
5.1 __ >-------+---1 AvgMonHy(Cono.): I-----------
I-GeorMtric M-(Conc.):....___
MaxAvgWN/tdy(Loact): ~09
__ ~ ______!:,!__
1
~
---~
4_
I~
~
AvgMonlhly(Load): ~ft C ~
1~
0._3 __
--- TolllMonllly(loed):
0.038 C
3 C
3 1
0 Q
1--
I-I-
1--
I-I-
I-I-
1--
I-1--
I-I-
1-1-
1-1--
1-1-
1-
--- I-I-
1--
-- ---1------
__.j I-I-
I-Q 0
Q Q
C--- t-Q 1------
1-----
1----
I---
1---
1---
DlllyMinmum(loed): -----0:001 _=_
--. -.2-l~
or-
---*- t-- -
DoilyMmnumll.ood), 1,..,;D;;;.D:;;09;_.i......1, ____.l..;..i.::;::;::;;;;o.;;2::;_J,.,;..a, _ _;* ;,;;*3-...1,-.1..---...1,-.i..----'-.i..----'-.i..---""""""..1.---.,_.,_..1,, ____ 1,....L.----1.....1.----1.....1.----1.....1.----1......1.---....1 I certify undw pwialty r:I ft 11.t this cl:loumwlt ** pnipand under my dnollon or~
WI ~
.tth
- syst9m dNlgned lo *..,.,. l\\at qualflad penonMI gat,er-and evalunt hi lnfonndon submllt.d. BNad on my lnqUlry ol,._ s--on or.,.-.on* who~ t,e syallm or fW>M peraons dlrecly l'Npatl.._ for gathemg '- lflfonnalon, '- informdon aubrnltad Is, kl,._ bNt r:I my knowledge and bellf, he,__.., and~. 1.,,...,..
l\\al:8'er9.. tilgnlflcw,tpena111Nforautlmlllngfa1Nlnfonnalorl,~--~olflneandlr'npillonlnWltforknowlngWllallorls. SN18Pa.C.S.§-4CMM(Nla9nvklunswomfnlflcatlon).
Prepared By:
James Harvey TIiie:
Senior Nuclear Specialist License No.:====--------------
Date:
_,9tl::..:..:3120=:::2:3 _____________ _
g pennsylvania J.-
DEPARTMENT OF ENVIRONMEHTAL PROTECTION Facility Name:
Municipality:
ShlpplnaPorl Borough Watershed:
20-8 Laboratories:
TH!Amerlca. BVPS Lab 3100-FM-BCWO.U5 3/2012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
Month:
L<-**->
Year.
2023 Permit No.: PA0025615 Outfall:
-=1~02;=..----
Renewal application due 1&.mn prior to expiration.
This permit will expire on:
_,Oc:tobe===-' 3:.1:i,.::20;:::26:::... _____ _
"1--.Fir~:;;-+-;;-.--:-::~;.;--+-;;-r-rs-R-::~::.-+-;;oc-rrr *_*_:-::~::'":.*-H-t-,;,----t-;.,----t-;.,----h::,----+-:;;,----+;;-,----+:;;-,,----+-=--r----+-:--r----+.,,...,,-----1--,,....,-----ll e
MGO Q
SU Q
Q Q
Q Q
Q Q
Q Q
Q Q
Q Q
1
~
7/30/23 -
--f-----
~
7/31/23 Tue 8/~
~ed 8/2/23
,____..!hu Fri
~
~
--~
Toe
--~ed r--,:-hu Fri
--~t 3
Sun
- ~"
~
Tue Wed
~
f-----Fri Sat 4
Sun
- ~"
r,e
- ~ed
~~
Fri
~
-.- ~
Mon
-f-----
Toe Wed
--r""
Fri Sat 8/3/23 8/4/23 8/5123 818~ _
8/7/23 8/8/23 8,lgf23 0.001 8/10/23 8/11/23 8/12/23 8/13/23 8/14/23 8/15/23 0.001 8/16/23 8/17/23 -
8/18/23 8/23/23 8/24/23 8125123 8126123 812.7/23 --
8128123 8129123 8/30123 8/31/23 ~
G/1/23 912123 --
Daly Minimum (Cone.): -
DallyMmnutn(Conc):
MaxA1o9 WNkly(Conc.):
A..,g Montiy (Cone.):
Gecmwtc u.... (Cone.):
Ma A"V WNkly (Load):
0,001
~
A"9 Monf'dy (Load):
T ota1 Monthly (Load): "-u.002 Dally Minimum (load): ~
Daly MmT'IUffl (load):
0:001 f--
7.5
~ ~ 4.0 7.4 4.0
-f--
1.*
~.5 0.03 - -.
--~
0.03.
1
-f-----
0.03.
0.03-.
5.,---
4.9 __ _
5.1 5.1 5.0 0.04 0.04 1---
o~ -
0.04
1------<
f---
-c----------
f---
f---
f---
f----
-f-----
-f---
I o.rlfy under penally of _flat IMS doounwlt WM pwpaNd undw my c:hctlCln or~
In acoordanoe wll'I
- syst.m dNignect b auure IMll quallftecl penonnel gd,er' and eWlklal9 lhe lnfonndan aubmltlld. Buad on my lnqlay of lie peraon or per901'1S who IMMIO'I IM-SyNlm or h,N peraons clrwcly JNpon..,.. for gaf..tng the lnformallon, the Information aubmltlld II, b lie bNI: of my lcnoiMlldge and belllf, true, aocu..- and oomplala. I am-.
11111,-... slgrMflcantpenalllNforaubmllllng,.... lnfcrmdon, lncludlng lhepouiblllyofflneand lrnpriaonmentforknowlng vicAatlons, S.. 18 Pa. C.S. § 4'104 (rNdlng bunswom fallfflcatlon).
Prepared By:
James Harvey Trtle:
Senior Nuclear Specialist License No.:====---------------
Date:
_,917=/20=2aa3 _____________ _
---f-
---f--
f---
1-
- I--
~
1-1-
~
pennsylvania f".11 ~OFENVIRONf'ENTAL Facility Name:
- a...., Valley p.,_, Station Municipality:
Shippingport Borough Watershed:
Laboratories:
THtAmerlca, BVPS Lab llOO-FM-eC'MM35 3/2012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
Month:
.!..._ c""""",u....,>
Year:
2023 Permit No.: PA0025&15 Outfall:
"'1~03="'" ___ _
Renewal application due !HJ!ln prior to expiration.
This permit v,;11 expire on:
-'Oct=obo=r'-'3'-'1"-, =-20:.:2:.:6 ______ _
Flow pH TSS OUandGru..
w Day
- at'"!!!1--M-GO~-+-a~-R_ls-.u--t-a~-- ma11.
~-+~a~--ma11.
~
+
~a~----+-,a~----+-,a~----+-a"""'----+a~----+~a--r-------,l-=a--r--
---1--,a~----l--,a~----l--,Q--r-------,f-a--r-----ll
- --- 1-- f-- --+---t----ff----+-
Sun 7/3012.3 Mon 7/31123 Tue 8/1/23 Wed 8/2/23 0.130
~
8/3/23 0.152 f-------
Fri 8/4/23 0.140 - --
Sat 8/5/23 0.135 1-2 Sun 8/6/23-0.130 -
Mon 817/23 0.128
>-- ---+--
Tue 818123 0.139 -
Wed 8/l>/23 0.143
--7.2 Thu 8/10/23 0.135 --
4.0 5.1 -
--+-
-f------f-
-+-----f-
-f--
Fri 8111'23 0.136 --
Sat 8/12/23 0.149 -
I-Sun 8/13123 0.149 -
Mon 8/14/23 0.138 Tue 8/15/23 0.134 -
--7.0 4.4 4.0 Wed 8/16/23 0.137 Thu 8/17/23 0.134 Fri 8/18/23 0.146 Sat 8/1Q/23 0.137 1---
Sun 8/20/23 0.149 Mon 8121/23 0.136
- -----+--fc----+-f---f----
Tue 8/22/23 0.135 Wed 8/23123 0.134 Thu 8/24123 0.132 -
Fri 8/25/23 0.139 I~
8/28/23 0.146 -
~
Sun 8/27123 0.147 -
f--
- - ----+---+--
Mon 8/28/23 0.146 -
f--
Tue 8/29123 0.137
>------+-
4-Wed 8/30/23 0.141 -
f--
Thu 8/31/23 0.148 Fri 9/1123 Sat Q/2/23 Daily Minimum (Cone.):
4.9 Daily Maximum (Ccftc):
7.2 5.1 Max A"V w-,, (Cone.):
4.4 5,1
-f----- f--
~~-
5.0 Avg Mont\\Jy (Cone.):
I--- -
- f----+----t--+----+---
GeomNtc Meal (Cone.):
Ma: Avg W..tiJy (LNCI):
0.144 A"'V MonHy (load): 0.139 ToWMonlhly(Load):
4.182 150 1711
,-----+----<-
- -~
DIiiy Minimum (Load):
0.1211 5
Ody Maxim.Im (l.Olld):
0.152 I o.r1lfy undar penalty of law ht"'- document-. ~
under my dlNction 01" aipr'llalan In aooa,danoe with
- Sy&lllm designed _, HSUN lhat quallfted penonnel gather Md............. Information aubmltlad. B*Md on my
"'4,llryofthe per90n or peraonswho nwiac,at,e sysl9morthoee pa.onsdncty NepOnstiafargathetlng 1he L-lformatlon, lhe Information aibmltt.d Is, ID the beat of my knowildg,s and belief, true, accumis and oornplete. I am_,.
ttat....,... slsJ'lll'lcant.,.,_.....forsubrritllngfalsell'lformllbl.~fMiponllatydflMandtmprts,onmantforknowlng\\llDldarls. S..18 Pa. C.S.§4DCM(n,ldngt0un11WC11nffllslflcdoni Prepared By:
James Harvey Tttle:
Senior Nuclear Specialist Ueense No.:
Date:
-=9'7=120=23=--------------
-- f--
- f---------
f--*-f-1- -
--f-----
9 pennsylvania r~ DEPARTMENT OF ENVIRONMENTAL
'at/!§ PROTECTION Facility Name:
- a.... r Valley Power Station Municipality:
Shippingport Borough Watershed:
20-B Laboratories*
TootAmerlca BVPS Lab I
Flow TRC 1
RI w...
Da*
Dale MGO Q -
1 Sun 7/30/23 Mon 7/31/23 Tue 8/1/23 0.0 Wed 8/2/23 Thu 8/3/23 Fri 8/4/23 Set 8/5/23 2
Sun Bte/23 Mon Sll/23 Tue 8/8/23 0.0 Wed 8/Q/23
--,_______ll><,__
8/10/23 Fri 8/11/23 Set 8/12/23 3
Sun 8/13/23 Mon 8/14/23 Tue 8/15/23 0.0 Wed 8/16/23 Thu 8/17/23 Fri 8/18/23 Set 8/19/23 4
Sun 8/20/23 Mon 8/21123 Tue 8/22/23 0.0 Wed 8123/23 Thu 8/24/23 Fri 8/25/23 Set 8/26/23 5
Sun 8/27/23 Mon 8/28/23 Tue 8/29/23 0.0 Wed 8/30/23 Thu 8/31/23
--, __ F_rt ___
Q/1/23 Set 912123 Daly Mtnmum (Cone.):
Dally Maximum (Cone):
MaxA'llgWeekly(Conc.):
Avg Monthly (Cone.~
Geon-.tric MMn (Cone.):
Max AYg Weekty (Load):
Avg Monthly (Load):
Total Monthly (Load):
Dally Minimum (Lo-.::1):
0 Dally Maximum (Lo.cl):
0 Q
3800-FM-BCW0435 312012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
- a.... r Month:
.!_(Ntectaum""')
Year:
2023 Permit No.:
PA0025615 Outfall:
"'=1"08:'-'-----
Renewal application due ~
prior to expiration.
This permit v.ill expire on*
October 31 2026 I
Q Q
Q Q
Q I certtry under penally of 111w that 1hts document-* pn1p11red under my drection or au~ In acoordance wfth
- ayalem designed le hMJrw that qualfled peraonnel gather and ewiluate the lnfonnation aubmltt.d. Basad on my Inquiry of the peraon << persona M'IO manage the ays'9m or lhoN pwaona dlrectly reaponstile for gathering the Information, the lnfarmall0n submitted Is, to the beet cl my knowledge and belief, true, accurate and complete. I am 111W11r1t that "-9 are elgnlflcant penalties for submitting flllae Information, lncludlng the poulblllty dftne and ln,prilionment for knowing vkllatlon*. See 19 Pa. C.S. § 4004 (r.i.tirtg to unsworn fallfflcation).
Prepared By:
James Harvey Tille:
Senior Nuclear Specialist License No.:~==---------------
Date:
.. 9'7=12... 0
__ 2 __ 3 _____________ _
Q Q
Q Q
Q Q
Q
g pennsylvania J-DEPARTMENT Of ENVJAONMElfTAL PROTECTION Facility Name:
Municipality:
Shlpplnapoot llorouph Watershed:
2CMI Laboratories:
3800-FII.SC'M>435 :t/2011 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
- a....,
Month:
8 c,_., *..,.,
Year:
2023 Pennlt No.: PA0025615 Outfall:
-=1::c11=-----
Renewal application due 1H..Hn prior to expiration.
This permit will expire on:
~Octobe~--* 3~1~1_20~26~------
"1-----:F,::l~:::--+-::-r--:-,~=-+-::-r-TS-R_~-.-+-::Oc-lr-l *_*_dR_~_,.-:----1-::,-,-----f-::--T----f-::--T----+-,=-,----+,::-,----+-::-r----+.,,...,,----+=-.----+~.----+~.-----1-~-----1 1ay M
SU mnA rnM Q
Q Q
Q Q
Q Q
Q Q
Q
--f-----
-f-
--f-
-f-
-, - ~n 7!30/23
--f--MOO 7/31/23 -
--f--------------
f-- -
Tue 811/23 0.002 o--
r-W
~ ed-812123 7.5 -
~
4.0 4.0
-f---
-~
8/3/23 o--t-Se
~Fn_~
=~: _
2_ ~
8/tl/23==--
-f-----
~
~8/7
= /2~3--~
~~
!':.~
_ 0.002 1.g ___ 4.e 3._. ___ _
--~
8/10123
---f--
l
--r-Fri 8/1H23 i-1--
-- -f--
- ~
8/12123 *-
1- -
3 Sun 8/~ =-
- >---1-------
- --+-
--~on _ 8/14/23 ~
002 77 7.0 -
~
Tue 8/15/23 5.0
-f----
--f-
-- ~
8/1~
==-
Thu 8/17/23 f-----
SeFri 1
8/18123 _
- I--- _
1------ _
8/19/23 __
4 Sun 8120/23
t---+----+---
f-----
Mon 8121/23 0.002 7.3
-,~----~
Tue 8/22123
~
4.0
- c s.2
---+--t-r-t-----t--t----
-=~
- *~
=-
~ ::~: - --+--+-
-f---------
-f---------
--f--
-+-
+--- --f-Sat
~/23 ~n - ~
Mon
~
0.002 --=:==e~.. ~-_+ _--,f--~-5.5_
-,...-*-,..._-_-4.=*===+--+-------,.- _____ -
- i------
---r-!': - =~: -
+------,1--t------,I--+-
~
Thu 8131/23 ---
I-
--+---f----+---f- -----,1--+----t---+----t---+-----i-
-f----
- ~
'W1/23 --
Sat 01212.3 Daly Minimum (Cone.}:
3.9 Daly MbfflJm (Cone}:
-~
~
7.0 7
Max Avg W..iity (Cane.):
7.0 5.2
- 5.-2--
--l- -+ ----+---1 -----
---f-I-----+
---f-
t---t------1
- --- +--+---
-f----
1-----+-- -f------
1---f---
~ ----f--l----+---+----
f--
~- ---------1--- -
A'4 Montlly (Cane.):
Geomel'ic M..-. (Cone.):
MIIXA"9W...,,,(l..oad):
0.002 Avg Monllly (load):
0.002 Total Monthly (Load):
0.01 DIiiy Minimum (load):
0.002 DIiiy MalnMn (load):
0.002 5.0
-+--11-~~--f--*-+--~**_L_ -
+ -----l-
-+-----lf-- -r-----+--
1-------
0.1 0.09 0.08 3
o.oa
-+--. -f--
2-- -
0.07 0.1 0.07
-+-
t------t---,1-----.~
+
~.-1 ~
t------+-
t---
- -- 1
---t--
-t-----J -~
1 cer11ry undlr pana11y ol._ M"" documant._ prepaN under my dncllon <<...,.,...,,. 1n accordano9 w111 sya,m dnlgned to...,,. flat quallled peraonnet gattw and......,. the lnformallon -.,t,mitad. e...i on my 11'1.,iryolhtpanon orparwons~ managa,.. ayailm orlKINper90nsdlrect)'NeflO'l..,..for~ 1'111 lnfanndan, lie lnfcrmdon IUtmltad Is, to the bNlolmy knowledge and blhf, we, -,cu,_ and oornplea. I am..,.
lhatthtn-llgnlftcantpenalllnforlUbmltllngflllNlnfonnalon,lncludlngthtlpoulllltydflnilandlmpMonnwntforknowlngvloldon*. s.. 1eP.C.S.§~(rutingtounNDfflfalafflcation).
Prepared By:
James Harvey
Title:
Senior Nuclear Specialist License No.:-===:::c---------------
Date:
_,911....,3/2023==--------------
@ pennsylvania J~ DEPARTMENT OF ENVIRONMENTAL a:t!!!/1 PROTECTION Facility Name:
a.-ValloyPowerSullon Municipality:
Watershed:
Laboratories:
w 1
Sun Mon Shlpplnapo,t Borough 20-8 THIAmerica, BVPS Lab Flow D te MGO 7/30/23 7/31/23 Q
pH RI s.u.
Q Tue 8/1/23 0.002 1.2-
'-l-Wed 8/2123 Thu 813/23 Fri 8//23 Set 815123
_ 2_
Sun 816123 Mon 1--. 8/7/23 Tue 8/8123 '---~-'o"-'.00=2-'-
1.1 Wed B/0123 Thu 8/10/23 Fri
-8111/23 -
Set 8/12/23 3
~
n 8/13/23 3800-FM-BC\\\\'0435 S/2012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
TSS RI
- a.....,
OIi and Gr.as*
RI Q
Q Month:
L c-_,
Year:
2023 Pennij No.: PA0025815 Outfall:
..:;:21;a;1=-----
Renewal application due 18l!J!nl prior to expiration.
This permit -.ill expire on:
~Octobe==*~3_1,~20~26~------
Q Q
Q 1-----l- -t---- --1 4.0 _ _
< f----"4.-'-' -
-+-
+---
7.0 3.0 Q
Q Q
+------l ---
f-----
-+-
+-----1-- I-Mon 8/14/23 0.002 6.9 _
7.2 S.2 -t-----l- -t--
Tue 8/15/23 Wed 8/16/23 Thu 8/17/23 Fri 8/18/23 Set 8/10/23
,~
Sun 8/20/23 Mon
~
1/23
= "--!-'==*---->- -
0.002 6.8 Tue 8122123 4.0
,_,_Wed 8/23/23 Thu 8/24/23
- s-
--~
Set 8125123
-~;~~ 1-----L--l-Mon 8128123 0.002 7.2 7.4 S.O
, __ Tue M,9123
-- __'!!ed 8130123 Thu
~1/23
--Fri 9/1/23 Sat -
912123 Daly MlnlmUm (Cone.):
u 3.i Daly Ma>dmum (Cone):
7.7 ___
H 5.6 Mo AYg WNkty (Cone.):
7.0 5.0 AY; Monthty (Ccnc.):
- . o I-
-~
Geomal1o Mean (Cono.):
MaxA"9W...,,,(LOIICI):
0.002 IT 0,09 AYgMonflly(la.d):
0.002 0.1 o.os Total Monl'lty (Load):
0.01 3
2 Dolly-(l-0.002 0,07 0.07 Dolly......... (lced),
0.002 0.1 0.09 I °""'Y....,.penalyolllwl'IIII: Ha~-.,,.,,.,.ct undwmy...., or~~ ~\\!14th* a)'IWn...,_, lo---. htquall'lad,--Mlgalwr and........ hlnfamr.bol ~.
Bned on my lnqUlryoflt'9,--or,__.~.,,..._11ea)'911fflorhNpenoo.clldyrwpor,.._for~hlnfomalon.hlnfonMlonlUbmftlldls,lo,._NillofmykncMtlldgaandbellef,we,_,....anct~.,.,,..,..
t,at....,... ~tpanalllaafortubmlttlngf.... ~.
lnculng lhe ~
of the and ~for knowing....,,, *. S-18 Pa. C.S. § 4004 (~
lo un-,m t..fflcetion).
Prepared By:
James Harvey Trtle:
Senior Nuclear Specialist License No.:-====---------------
Oate:
_,911=3/2=0=23=---------------
f-----+-
+--
Q Q
Q Q
- -t--Jf---- -t--Jf-------1--
I----<>---+-- -----I!
_.__ I - -
1--- -
I-
-'----'-- --J..-- ----
G' pennsylvania r.-
DEPARTMEHT Of ENVmONMENTAL
'aJl:Jl!!!!I PROTECTION Facility Name:
S.WValloyP-Slallon Municipality:
Shlpplnplt Bonluph Watershed:
Laboratories:
TNIAmeflca, BVPS Lab 3100-Fll-8CV\\I0435 ll2012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
Month:
8 <,......._l Year:
2023 Pennlt No.: PA0025615 Outfall:
-301~~---
Renewal application due 1H.J!1D prior to expiration.
This pennlt win expire on:
.. October==--3"-1"',""20"':zs=-------
F~
- ~
OllandR~---
11--M-OO~-+-Q,..,.------+-Q~--......
---+-a~----t-,Q,-,-----+,Q=--r----+,Q=--r----+,Q::,----+-=a-.-----1-,,Q-.----1~Q"T"----t-::Qc-r-----t-::Qc-r-----t-::Qc-r----1~Q-.------i Sun 7130/23 Mon 7/31/23 Tue 811/23 Wed 812123 Thu 813123 Fri 8/4123 Sot 8/5/23 Sun
""'123 Mon 8/7123 Tue
.,.,,i3 Wed 8111/23 Thu 8110/23 Fn 8/11/23 Sat 8112/23 Sun 8/13/23 Mon 8/14/23 Tue 8/15/23 Wed 8/16/23 Thu 8/17123 Fri 8/18/23 Sol 8/10/23 Sun 8120/23 Mon B/21/23 Tue
_ 8122123 Wed 8123/23 Thu 8/24123 Fri 8/25/23 Sot 8/26/23 Sun 8/2.7/23 Mon 8/28/23 Tue 8120/23 Wed 8/30123 Thu 8131123 Fri 0/1/23 s..--- f-- 0/2/23 OlllyMlnlnUm(Cono.):
DlllyMll!dl'nwtl(Conc):
Max Aota Wet,Wy (Cone.):
A"t Mcinflly (Cone.):
Geoffl9t1CU..(Conc.):
MaxA"9W.....,(load):
A'9-(loodt TolllMontlly(Laad):
"""-(1.oodt
°"",._IL_
00 00
-f-----
0.0 f--- -
00 f--- -
00 f--- -
f---
f-
-f---
- f--- -
f-----
-f------
t----- -
I catty undw ~
el llwl'IIII:.,.. document._.,,,..,.,,_. undlr "'f dlreolCln or.,._..., 1n ~
-.lfl *.yam dNfip,ed D n9WW.,_.,.._. penonMI Ollw and....._.,_ lnfarmdon ~
8ned on my 1nQUtyelhpenonarpa,90fta.tio__,.,.t.syaamort,oee,perwon9dlfdyrwp,nltilifllrgalwlrlghlnlcnMlon,hlnformlllonMllfflllldta.1Dflei.stelrrry~andballf,we,aocurwandoc:imp9t1,. lam.,..
IMlllef9.. lllgnfflowlt,...._forllUbma,g,._lnfomwllon,lncMlnfh~ollNand~forlcnaM'CI.....,,,_, S..11Pa.C.S.f"°°'(~IDIMNOfflWllfloalaf,).
Prepared By:
James Harvey Tl1!e:
Senior Nudear Specialist License No.:
Date:
"'stt=l/20=,.,,23-=--------------
f---
f-
-f---
f---
t-----
--f--
---f--
- -f--
f-f--- -
f----- -
f--
Facility Name:
Beaver Valley Power Station Municipality:
Shlpplnppo,t Borough Watershed:
20-II Laboratories:
TeotAmertca BVPS Leb Flow pH 1
RI MGO s.u.
1 Sun 7/30/23 Mon 7/31/23 l-Tue 8/1/23 0.0 Wed 8/2/23 Thu 8/3/23 Fri 8/4/23 Set 8/5/23 2
Sun 8/e/23 Mon 8/7/23
--~
8/8/23 0.0 Wed 8/0123 Thu 8/10/23 Fri 8/11/23 Set 8/12123 3
Sun 8/13/23 Mon 8/14/23 Tue 8/15/23 Wed 8/16/23 0.0 Thu 8/17/23 Fri 8/18/23 Set 8/19/23 4
Sun 8/20/23 Mon 8/21/23 Tue 8/22/23 Wed 8/23123 Thu 8/24/23 0.0 Fri 8/25/23 Set 8/26/23 5
Sun 8/27/23 Mon 8/28/23 0.056 6.6 Tue 8/29/23 0.056 6.5 Wed 8/30/23 Thu 8/31/23 Fri 9/1/23 Set 912123 Daly Minimum (Cone.):
6.5 Daly Maximum (Cone): '-
6.1 Max Avg WNkly (Cone.): ~
Avg Monlhly (Cone.):
Geometrtc Meai (Cone.):
Max Avg Weekly (load):
0.056 Avg Monthly (load)*
0.019 TotalMonthly(LoMI): ~
Daly Mhimum (Load):
0 Dally Maximum (load):
0.056 Q
3800-FM-BCW0435 312012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
Beaver Month:
L<"""""**m""')
Year:
2023 Permit No.: PA0025615 Outfall:
-=3~03:'-'-----
Renewal application due 180 days prior to expiration.
This permit will expire on:
-'O'-'ctobe==*~31~1~20~2~6~------
TSS OIi and Gruse RI RI Q -
Q Q
Q Q
4.0 4.9 4.0 4.9 4
4.9 4
4.9 4.0 4.9 4.0 4.9 2
2 2
2 58 71 2
2 2
2 I certify under penalty d law that thl* document 'MS prepaNd under my drection or aupe,!"Mlon In tlCCOl'dance with a system designed 110 anure that qualifl9d pw:11011nel gather and evaluate !he Information submitted. Based on my Inquiry d lhe pereon or pcnon11 who manage th* *yatl,m or lhoN penons dlrectly '"l)Ol'labi9 for gathering the Information, the Information submlu.t I*, to the beat of my knawl<<fge and bellef, true, aocurete -,d complete. I am aware that1h<<11 are slgnlftcantpenllllleaforaubmlttingfalN informlltlon, hcludlng tie poNlbiltyofflne and lrnpriaon!Mntforknowlng Vlolatlons. See 1! Pa. C.S. § 4004 (relating tounawornfalslftcallon).
Prepared By:
James Harvey Trtle:
Senior Nuclear Specialist License No.:
Date:
"'911=312=0""2""3 _____________ _
Q Q
Q Q
Q Q
~
~ ---
~
~
~
g pennsylvania r,,a,g DEPARTMENT OF ENVIRONMENTAL
'.:l!!!I PROTECTION Facility Name:
Beaver Valley Power Station Municipality:
Shippingport Borough Watershed:
20-B Laboratories:
TntAmerlca BVPS Lab Flow pH 1
RI MGD Q
S.U.
1 Sun 7/30/23 Mon 7/31/23 Tue 8/1/23 0.002 7.3 Wed 8/2/23 Thu 813123 Fri 8/4/23 Sat 8/5/23 2
Sun 816/23 Mon 8f7/23 Tue 8/8/23 0.002 7.3 Wed 8/9/23 Thu 8/10/23 Fri 8/1H23 Sat 8/12/23 3
Sun 8/13/23 Mon 8/14/23 0.002 7.7 Tue 8/15/23 Wed 8/16/23 Thu 8/17/23 Fri 8/18/23 Sat 8/19/23 4
Sun 8/20/23 Mon 8/21/23 0.002 7.0 Tue 8/22/23 Wed 8/23/23 Thu 8/24/23 Fri 8/25/23 Sat 8/26/23 5
Sun 8/27/23 Mon 8/28/23 0.002 7.2 Tua 8/29/23 Wad 8/30/23 Thu 8/31/23 Fri 9/1/23 Sat 012123 Oaly M~lmum (Cone.),
7 Daly Maximum (Cone):
7.7 Max Avg Weekly (Cone.):
Avg Monthly (Cone.):
Geometric: Mean (Cone.):
Max Avg Weekly (Load):
0.002 Avg Monthly (Lo.cl):
0.002 Total Monthly (Lo.:!):
0.01 Daly Minimum (Load):
0.002 Daly Maximum (Load):
0.002 Q
~
3800-FM-BCY',10435 3'2012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
Beaver Month:
_8_ 1oe1ec1 oumbwJ Year:
2023 Permit No.: PA0025615 Outfall:
""3"'13""'"----
Renewal application due 180 days prior to expiration.
This permit will expire on:
..:Oct=o==be=-r =.31a..1.:2;::02::6'-------
TSS Oil and Grease RI RI Q -
Q Q
Q 4.0 4.0 4.0 3.8
~
7.8 5.1 4.0 5.2 6.3 5.1 4
3.8 7.8 5.2 7.8 5.2 5.2 0.1 0.09 0.09 0.08 3
2 0.07 0.08 0.1 0.09 I ca1ify under penalty of law that this document wn pn,p1r9d und9r my dnctlon or supervision In aocxwdanoe with
- system designed to HU'9 that qualllled personnel gather and evalum the Information aubmiltl9d. Baaed on my Inquiry of the person orperaons'MIO ll'lMgel the syalem orlhoN peraonadncty ruponalbleforgathertngfle lnformiltlon, the lnformdon aibmllt.d la, to 1h11 bNt.ofmy knowledge and belef', In.le, accunii. and oomplete. I.,,, aw.ni that th- -
algnlllcnt penaltlea for subrnltllng fa!N lnformallon, lncludlng the poa,llbllty offln* and lmpl'taonmentfor knowtng vloltlons. SN 18 Pa. C.S. § G04 (relating lo unawom falslflcllon).
Prepared By:
James Harvey noe:
Senior Nuclear Specialist License No.:
Date:
~1111=3/20="'2"3=---------------
Q Q
Q Q
Q Q
Q
-~
Facility Name:
Beaver Valley Power Station Municipality:
Shippingport Borough Watershed:
2CM!
Laboratories:
T-merlca, BVPS Lab Flow pH 1
RI w
Da ate MGO Q
s.u 1
Sun 7/30/23 Mon 7131/23 Tue 8/1/23 0.0 Wed 812/23 Thu 813123 Fri 8/4123 Sat 8/5/23 2
Sun 8/6123 Mon 8f7/23
-- T ue 818123 0.0 Wed 819123
-- I~
8/10/23 Fri 8/11/23 Sat 8/12/23 3
Sun 8/13/23 Mon 8/14/23 Tue 8/15/23 0.001 7.7 Wed 8/16/23
~ -
Thu 8/17/23 Fri 8/18/23 Sat Blrn/23 4
Sun 8/20/23 Mon 8/21/23 0.001 7.5 Tue 8/22/23 Wed 8123123 Thu 8/24/23 Fri 8125123 Sat 8126123 5
Sun 8/27/23 Mon 8128123 0.001 Tue 8/29/23 Wed 8130123 Thu 8/31/23 Fri Q/1123 Sat Q/2/23 Dally Minim.Im (Cone.):
7.S Dally Maximum (Cone): 1---
7_7 Max A¥1,li WNkly (Cone.):
A¥g Monthly (Ccnc.):
Geometric M.., (Cone.):
MaxA¥gWeekly(Load):
0.001 A.¥1,li Monflly (Load):
0.001 Total Monthly (Load):
0.003 Dally Mlnfflllm (1..oMI):
0 DIiiy Max.mum (Load):
0.001 Q
3800-FM-BCW0435 312012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
1141.,,.,
Month:
(M4ect,u,...,)
Year:
2023 Permit No.: PA0025615 Outfall:
"".io"'1':"'------
Renewal application due 180 days prior to expiration.
This permit Y<ill expire on:
-'O"ct"'o"'be"'r"3~1., ~20~2"'6 ______ _
TSS Olland Grean RI RI Q
maA.
Q Q
Q Q
4.0 4.0 4.0 5.2 u
5.2 5.2 5.1 0.03 0.04 0.03 0.04 1
1 0.03 0.04 0.03 0.04 I oartlfy under penalty c(f lew that thts docunwit -
prwpar-.d undw my drectlon or supervision In acoordance wllh systwm designed to HIUl'II that qu"""-d penonMf ga'- and........... the Information subrnitl9d. Based on my inquiry ril the pen,on or perwons IMIO manage the aymm << those perwons difectiy rwaponaible for gathering the Information, the lnfcnnatton submitted la, to ht bnt d my knowledge and bellef, true, IIOCUratll and oornpl9te. tam aware thlll:thetetn aignlllca,t penatttnforaubmltllngfalN lnfonnatlon, lndudlng lheposdilltyoftlne and lmpriaonmentforknowtng -Aolatlona. SN 18 P. C.S. § -4Q04 (rutlng tounSW'ClfTI falafflc:tion)
Prepared By:
James Harvey TiUe:
Senior Nuclear Specialist License No.:~==~--------------
Date:
-'9/1=3/2=0~23~------------
Q Q
Q Q
Q Q
Q
@[d pennsylvania DEPARTMENT OF ENVIRONMENTAL
""°1£CTlON Facility Name:
- a.... r Valley Power Station Municipality:
Shippingport Borough Watershed:
Laboratories:
TfflAIMllca. BVPS Lob Flow pH RI MGD Q
S.U Sun 7130123 Mon 7131/23 Tue 8/1/23 0.0 Wed 8/2/23 Thu 813123 Fri 8/4/23 Sat 815/23 Sun 8/6/23 Mon 8/7/23 Tue 818/23 0.0 Wed 8/9/23 Thu 8110/23 F~
8/11/23 Sat 8/12/23 Sun 8/13/23 Mon 8/14/23 Tue 8/15/23 Wed 8/16/23 Thu 8/17/23 Fri 8/18/23 Sat 8/19/23 Sun 8/20/23 Mon 8121/23 Tue 8/22/23 0.0 Wed 8/23/23 Thu 8/24/23 Fri 8125/23
---f--
Sat 8/26/23
~
8127/23 Mon 8128123 Tue 8/2W23 0.0 Wed 8/30/23 Thu 8131/23 Daly MlnlnMn (Cono.):
M~--:;=~=~: t------+-
+--
A"D MonHy (Cono.):
Geameiwk:MNll(Conc:.):
U.A'"'9W..,.,(l.Ollcf):
A.YIJMonl,ty(Lmd):
D==(~=t ---
-+-
+---
Q JIOO.FM-BCWG435 3'2012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
.!..,_c_""_,
Year:
2023 Permit No.:
PA0025615 Outfall:
-=40'c'3=------
Renewal application due Dl.!!m prior to expiration.
This permit \\Nill expire on:
_Oct_obe_r_3~1~, _20~2~6 ______ _
on and G,....
RI NH3-N RI Total Chromium Total Zinc RI RI Hydrulne RI Q
Q Q -
Q Q
Q f------
f--
1-1-
- --- ----- f--
Nalco H150M RI Q
Q 1--- ---+--- -
--+----+---4--
---+- +-----
t---+----t---+-----
Q Q
Q Q
f- --
1---+--
DallyMaxlmum(Lc>>d):..............
r_-
... ~
_,;..i., _____
,.l,., ____
i.,...1. ____
1.,...,1,, ____
1.,...,1,, ____
1,,- _
1,,
____ ____ l-.i.---...ll I certify undw penalty cf IN t,at 1h11 document 'MIS pwpared undlr my dr9Ction or auper,,illton In eocordance with a system desigMd ID assure that quallfled p<<sonnel plh<< Md evaluale lhe informdon tubmltled. Based m my 1nq.,trydhper90nor~*....tlomMage....,....,.,orttON,-.onadNcty,-pc)f'l..,._forgdlemg... lnformdon,htnt'omwDonlUbmiltadla,lolhebestofmykncw6edgeandblll9f,~,.oci.,..... s,cloomplea. lam-.
tlat'--signll'tcn per,IINMfor tubmlttngfalN lnfonndon, hdudlng the poulllltyofftneand mprilorvnantforkrKM4ng vlolalana. S..18 Pa. C.S. § -4804 (,Wtlng ta unaworn falalflcdon~
Prepared By:
James Harvey Tille:
Senior Nuclear SpeciarlSI license No.:
Date:
-=917=120=2"'3 _____________ _
g pennsylvania J~ DEPARTMENT OF ENVIRONMENTAL
'a:!!!I PROTECTION Facility Name:
BellY9r Valley Power Station Municipality:
Shippingport Borough Watershed:
20-B Laboratories:
TnlAmerlca BVPS Lab Flow pH 1
RI MGO Q
s.u.
--~-
1 Sun 7/30/23 Mon 7/31/23 Tue 8/1/23 0.0 Wed 8/2/23 Thu 8/3/23 Fri 8/4/23 Sat 8/5/23 2
Sun 8/<l/23 Mon 8ll/23 Tue 8/8/23 0.0 Wed 8/9/23 Thu 8/10/23 Fri 8/11 /23 Set 8/12/23 3
Sun 8/13/23
--~
8/14/23 Tue 8/15/23 0.0 Wed 8/16/23 Thu 8/17/23 Fri 8/18/23 Sat 8110/23 4
Sun 8/20/23 Moo 8/21/23 Tue 8/22/23 0.0 Wed 8/23/23 Thu 8/24/23 Fri 8/25/23
~
8/26/23 Sun 8/27/23 Mon 8/28/23 Tue 8/29/23 0.0 Wed 8/30/23 Thu 8/31/23 Fri 9/1/23 Sat 9/2/23 DIiiy Minimum (Cone.):
Dally Mntmum (Cone):
Max A\\Oi Weekly (Cone.):
A"II Monthly (Cone.):
GeometricM...,(Conc.):
MaxAYgWeekly(L<-.:i):
A-.,gMonthty(l..Olld):
T obll Monthly (Load):
Dally Minimum (Load):
0 Daly Maximum (Lo-i):
0 Q
3800-FM-BCW0435 312012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING County:
- e....,
Month:
8 (Nloctnu..._)
Year:
2023 Permrr No.: PA0025615 Outfall:
-=&0-=-1:-'--'-----
Renewal application due.1!!!!J!nl prior to expiration.
This permrr will expire on:
..:0:..:-==-'"'31"1"'20~26=-------
TSS Oil and GreaM NH3-N Hydrazine RI RI RI RI Q
ma,\\_
Q -
Q Q
Q I certify under penalty of law ht 1h11 document wn ~
under my dncbl or -..pervlalon In acoordllnoe with
- s)'nlffl designed to UUN lhllf: ~
~nel galh.- and evaluate the lnfonndon aubmlttad. Based on my lnql.llry,Af,e penon orperaons who,n-,age h sysllm or lhoN personsdlrecty rnponslbleforgathwlng hlnformallon, the Information subrnttled Is, to the bNt rAmy knowledge and belief, true, 1100Urat.and complete. I am awa~
lhat there.. agntficant penllln for submitting false Information, lnducln; the ponlbllty rAfine and lmptonmentfor knowln; Violetlons. s-18 P. C.S. § 4Q04 (r91atin; to unsworn flalfiction).
Prepared By: James Harvey
Title:
Senior Nuclear Specialist License No.:
Date:
-:917=12"'02=3--------------
Q Q
Q Q
Q Q
Q
Facility Name:
Municipality:
Shippingport Borough Watershed:
Laboratories:
TootAmerica BVPS Lab Flow 1
MGO 1
Sun 7/30/23 Mon 7/31/23 Tue 8/1/23 0.0 Wed 8/2/23 Thu 8/3/23 Fri 8/4/23
~ 815/23 2
Sun 8/6/23 Mon 8{7/23 Tue 8/8/23 0.0 Wed 8/9/23 Thu 8/10/23 Fri 8/11/23 Sel 8/12/23 --
3 Sun 8/13/23 Mon 8/14/23 Tue 8/15/23 0,0 Wed 8116/23 Thu 8/17/23 Fri 8/18/23 Set BJ1g123 4
Sun 8120123 Mon 8/21/23 Tue 8/22123 0,0 Wed 8/23/23 Thu 8/24/23 Fri 8/25/23 Set 8/26/23 -- s~ 8/27/23 Mon 8/28/23 Tue 8/20/23 0,0 Wed 8/30/23 Thu 8/31/23 Fri 0/1/23 Set 0/2/23 Daly Minimum (Conc.):
Daly Maximum (Cone):
MaxAYg Weetdy(Cono.):
AYg Monthly (Cone.):
Geometric MMn (Cone.):
Max AY!il WNldy (LOlld):
Avg Monlhly (LOlld):
TotalMonthly(L.Olld):
Dally Minimum (load):
0 Dely Maximum (Load):
0 pH RI S.U Q
3110o.FM-BCW0435 3/2012 SUPPLEMENTAL REPORT DAILY EFFLUENT MONITORING Month:
.!._I""""'"""""")
Year:
..:2:.:0;::2;::3 ___ _
County:
Boavor Permit No.: PA0025615 Outfall:
..:7.:0..:.1 ____ _
Renewal application due~ prior to expiration.
This permit will expire on:
..:o:.:-==-*=-31,,,-=2=02&=-------
TSS OllandGNaH NH3-N Hydrazine RI RI RI RI Q
Q mg,I.
Q Q
Q I 08ftlfy under penalty d law lhat lhls docurnant -
pn,par.t undw my dnctlon or tupervtalon In IIOCOftlance with sytem designed to nure that qullfled pel"ICll'1nel g
lh<< #Id evlu te the Information submitted. Baaed on my lnqulrf d fie peraon or pn,ons who rNlfMlglt fMi system or lhoM person dnctty,-ponsti9 for galMrlng fie inforrnlllion, lh Information ubmitlld I, to the best d my knowledg #Id belief, lrue, aocurte and oompifti. I am_.,
t,at.,._.,. sls,llflcant penallln for submitting fl-Information, including !he poelbllty clflne nd lmprlonmentfor knowing \\lloldons. See 111 Pa. C.S. § 904 (relating lo unn,oom flibtion).
Prepared By:
James Harvey License No.: _________________ _
TiUe:
Senior Nuclear Specialist Date:
-=917=12::.:0;::2;::3 _____________ _
Q Q
Q Q
Q Q
Q
L-23-208 ENCLOSURE D
ft e,~~_!lOF~!~~~A~~!=o*
SUPPLEMENTAL REPORT - COOLING WATER INTAKE MONITORING 3800-FM-BCW0010 2/2020 Facility Name:
Beaver Valley Power Station - Unit 1 Month:
_Au_g.._u_s_t _______ _
Year:
Municipality:
Shippingport Borough County:
Beaver NPDES Permit No.:
PA0025615 Watershed:
20-B 20-D Renewal application due 180 days prior to expiration.
This permit will expire on:
October 31, 2026 Actual Intake Flow Cooling Water Make-Up Water Blowdown Volume Cycles of Actual Through Withdrawal Concentration Screen Velocity Day MGD MGD Million Gallons Million Gallons fps 1
1.47 2
1.61 3
1.4 4
1.42 5
1.49 6
1.48 7
1.39 8
1.43 9
1.49 10 1.49 11 1.54 12 1.65 13 1.62 14 1.47 I"
15 1.38 16 1.53
~
17 1.5 18 1.55 19 1.46 20 1.53 f.-
21 1.53 22 1.35 23 1.52 24 1.55 25 1.52 26 1.68
~
27 1.72 28 1.53 29 2.4 30 2.19 31 1.58 Average 1.6 Maximum 2.4 I certify under penalty of law that this document was prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. See 18 Pa. C.S. § 4904 (relating to unsworn falsification).
Prepared By: James Harvey License No.: -----------------
Title:
Senior Nuclear Specialist Date:
9n/2023 2023
'1A' e~~...,'!~!~~.~.~~o~cnON SUPPLEMENTAL REPORT - COOLING WATER INTAKE MONITORING 3800-FM-BCW0010 2/2020 Facility Name:
Beaver Valley Power Station - Unit 2 Month:
_AAJ
___ g_u_s_t _______ _
Year:
2023 Municipality:
Shippingport Borough County:
Beaver NPDES Permit No.:
PA0025615 Watershed:
20-B 20-D Renewal application due 180 days prior to expiration.
This permit will expire on:
October 31, 2026 Actual Intake Flow Cooling Water Make-Up Water Blowdown Volume Cycles of Actual Through Withdrawal Concentration Screen Velocity Day MGD MGD Million Gallons Million Gallons fps 1
2.34 2
2.0 3
1.95 4
2.07 5
2.03 6
2.11 7
1.96 8
1.96 9
1.98 10 2.08 -
11 2.11 12 2.04 13 2.03 14 2.05 15 1.98 16 1.85 17 2.02 18 2.05 ---
19 1.97 20 2.0 21 1.8 22 1.8 23 2.09 ---
24 2.09 25 2.13 26 2.13 27 2.11 28 2.2 29 3.58 30 3.58 31 3.17 Average 2.2 Maximum 3.6 I certify under penalty of law that this document was prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. See 18 Pa. C.S. § 4904 (relating to unswom falsification).
Prepared By: James Harvey License No.: -----------------
Title:
Senior Nuclear Specialist Date:
9n/2023
---