FENOC FirstEnergy Nuclear Operating Company Peter P. Sena III 724-682-5234 Site Vice President Fax: 724-643-8069 January 21, 2008 L-08-027 ATTN: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

Beaver Valley Power Station, Unit No. 1 Docket No. 50-334, License No. DPR-66 Eighteenth Refueling Outage Inservice Inspection Report Enclosed please find the Inservice Inspection (ISI) Summary Report on American Society of Mechanical Engineers (ASME) Class 1, 2, and 3 examinations performed prior to and during the eighteenth refueling outage at Beaver Valley Power Station Unit No. 1 (BVPS-1). The ASME Boiler and Pressure Vessel Code,Section XI, Article IWA-6230 requires an inservice inspection summary report to be submitted to the enforcement and regulatory authorities having jurisdiction at the plant site within ninety days of the completion of the inservice inspection conducted during each refueling outage. The recent inservice inspection term at BVPS-1 covered the period from April 20, 2006 to October 24, 2007.

The Class 1, 2, and 3 examinations are part of Interval 3, Period 3 of the BVPS-1 ISI schedule, and were performed in accordance with Section XI of the ASME Boiler and Pressure Vessel Code, 1989 Edition.

There are no regulatory commitments contained in this letter. If there are any questions or if additional information is required, please contact Mr. Thomas A. Lentz, Manager -

FENOC Fleet Licensing, at 330-761-6071.

Sincerely, Peter P. Sena III Enclosure

/

4-

Beaver Valley Power Station, Unit No. 1 L-08-027 Page 2 c:

Mr. S. J. Collins, NRC Region I Administrator Mr. D. L. Werkheiser, NRC Senior Resident Inspector Ms. N. S. Morgan, NRR Project Manager Mr. J. Payton, Commonwealth of Pennsylvania

BEAVER VALLEY POWER STATION UNIT 1 Route 168, Shippingport, PA Outage 18, Year 2007 Inspection Term: 4/20/2006 to 10/24/2007 Issue date:

1-11-0o6 Owner: FirstEnergy 76 South Main St.

Akron, OH 44308 NRC Docket Number: 50-334 Reactor Supplier: Westinghouse Electric Corporation Commercial Service Date: September 30, 1976 Reviewed by: ?

Df4"4L-g p&e,,. -*co 6V Supv, lKuclear Programs Reviewed by:

Lq.-" 9.

ANII Approved by:

O.

C -P'-...

(3,

e.

5 Manager, Technical Services Engineering Date:

/c

/8 Date: /-/I-o '"

Date:

I

90-DAY REPORT TABLE OF CONTENTS Item Page Number Cover Page 1

Table of Contents 2

Form NIS-1 3 -4 Outage Summary 5

ASME XI Vessel, Piping and Support Examinations

1. Class 1 5
2. Class 2 5-
3. Class 3 5

Reactor Vessel 10-Yr ISI 5

Pressure Testing 6

Deficiency Resolution 6

Steam Generator Tube Examination 6

NIS-2 Forms 6

Appendix I - Completed Code Examinations Appendix II - Repair/Replacement Abstract and NIS-2 Forms 2

FORM NIS-I OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules I. Owner FirstEnergy Nuclear Operating Company, Route 168, Shippingport, PA 15077 (Name and Address of Owner)

2. Plant Beaver Valley Power Station, Route 168, Shippingport, PA 15077 (Name and Address of Plant)
3. Plant Unit 1
4. Owner Certificate of Authorization (if required)

N/A

5. Commercial Service Date 9/30/76
6. National Board Number for Unit.

N/A

7. Components Inspected Manufacturer or

-Component or Manufacturer or Installer State or National Appurtenance Installer Serial-No.

Province No.

Board No.

Reactor Vessel Combustion Engineering 69103 105642B 21011 Pressurizer Westinghouse 1311 434676V 68-50 IA Steam Generator Westinghouse NP030651/IMB2 591601V 82 IB Steam Generator Westinghouse NP030651/2MB2" 591602V 83 IC Steam Generator Westinghouse NP030651/3MB2 591603V 84 IA Reactor Coolant Pump Westinghouse 1-618J931GO1 N/A N/A Reactor Coolant Piping Southwest Fabricating N/A N/A N/A Auxiliary Piping Schneider Power N/A N/A N/A Loop Stop Valve MOV-I RC-595 Rockewell International 7517 N/A N/A Relief Valve RV-I RC-55 IA Target Rock 69A N/A N/A Relief Valve RV-I RC-5511B Target Rock 69B N/A N/A Relief Valve RV-IRC-551 C Target Rock 69C N/A N/A RHR Heat Exhanger RH-E-IA Joseph Oat 1832-1 434682V 368 Low Head Safey Injeciton Pump SI-P-Ingersoll - Dresser 0671-140xxxxx N/A N/A IB 1

Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8/ in. x I I in.,

(2) information in items I though 6 on this report is included on each sheetand (3) each sheetis numbered and the number of sheets is recorded at the top of this form.

rhis form (E0029) may be obtained from the ASME Order Dept., 22 Law Drive, Box 2300, Fairfield, NJ 070012300 3

FORM NIS-I (Back) 10/24/2007

8. Examination Dates 4/20/2006 to
9. Inspection Period Identification:

12/3/2004 to 3/31/2008

10. Inspection Interval Identification:

9/21/1997 to 3/31/2008

11. Applicable Edition of Section XI 1989 Addenda None
12. Date/Revision of InspectionPlan:

'A-ADM-2039, Revision 7

13.

Abstract of Examination and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. See Appendix I (Code Exams) for exams performed duringIRl8. IRI8 was the second outage in the3 d Period of the 3P' Ten-Year Interval. This was the last outage in this period and interval. The Reactor Vessel 10-yr IS! exam was completed during this outage. All examinations, requiring plant shutdown conditions have been completed for the current 10 year Interval. The remaining eight examinations will be performed during plant operation prior the the Interval end date of 3/31/08.

14. Abstract of Results of Examination and Tests. See text of summary report.
15. Abstract of Corrective Measures. No Corrective measures resulting from NDEISI examinations were required inIRl8 We certify that a) the statements made inthis report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to.the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A Date 1/

L Signed FirstEnergy Nuclear Operating Co.

By-(Owner)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Connecticut have inspected the components described in this Owner's Report during the period 4/20/2006 to 10/24/2007 and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer make any warranty, expressed or implied, concerning theexaminations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss ofany kind arising from or connected with this inspection

____Commissions NB 9428 ANIB, PA 2384 lnspector'ignature National Board, State, Province and Endorsements Date 4

OUTAGE

SUMMARY

During the Eighteenth Refueling Outage (1 R 18) at the Beaver Valley Power Station, Unit 1, Inservice Inspection (ISI) examinations were performed on Class 1, 2, and 3 components. This was the second outage in the third period of the third ten year interval. The Class 1, 2 and 3 examinations were based on ASME Section XI, 1989 Edition.

ASME XI Class 1, 2, and 3 Credited Exams (See Appendix I)

1. Seventy-eight (78) Class 1 exams were performed and are divided as follows:
a. Welds (vessels, piping, and attachments)

Ultrasonic Exams 40 Penetrant Exams 3

Visual Exams 8

b. Class I bolting Ultrasonic Exams 4
c. Visual Examinations (VT-3)

Pipe Supports 12 Vessel Supports 3

d. RI-ISI piping VT-2 exams 8
2. Fifty-five (55) Class 2 exams were performed and are divided as follows:
a. Welds (vessels, pumps, piping, and attachments)

Ultrasonic Exams 3

Penetrant Exams 10

b. Supports, visual exams 14
c. RI-ISI piping VT-2 exams 28
3. Six (6) visual exams of Class 3 supports were performed:
a. Supports, visual exams 6

Examinations were performed by FirstEnergy Nuclear Operating Company (FENOC) NDE Technicians, supplemented with contracted NDE technicians from Integrated Technologies, Inc. (iTi). Appendix I compiles the examinations that have been credited toward fulfilling the Ten Year Plan requirements.

Reactor Vessel 10-Yr ISI The 10 year ISI automated examination of the BV I Reactor Vessel was completed by WesDyne International during 1 R18. FENOC personnel performed the manual UT examination of the threads in flange. The automated examinations of the reactor vessel yielded a total of 57 recordable indications.

Flaw bounding measurements for these indications were performed by qualified examinaers. All of the recorded indications were assessed against the criteria contained in ASME XI, IWB-3500 and were found to be within the allowable limits specified, with no further evaluation required.

5

Supplemental eddy current examinations of the dissimilar metal welds from the nozzle bore yielded no recordable indications. Remote visual examination of the nozzle inner radius areas (Enhanced VT) resulted in no recordable indications. Remote visual examinations of the reactor vessel interior and attachments (VT-1/VT-3) resulted in no recordable indications.

Pressure Testing The Class 1 end of interval pressure test was performed prior to plant start-up from IRI 8. All Class 1 bolted connections were examined during 1R18. Also, Class 2 and 3 system functional and system inservice tests were performed in accordance with 40-month pressure testing requirements.

Deficiency Resolution There were no recorded ISI NDE deficiencies in 1R18.

Steam Generator Tube Examination One hundred percent of the in-service tubes were examined in the three generators. Results of the examinations are submitted to regulatory authorities per Technical Specification requirements.

NIS-2 Forms Included as Appendix II are the NIS-2 Forms associated with repairs and replacements. Code Case N-416-1 or N-416-2, Alternative Pressure Test Requirement for Welded Repairs or Installation of Replacement Items by Welding, Class 1, 2 and 3, was used. The NIS-2 specifies when the Case was implemented and which revision was used.

6

APPENDIX I 1 R18 Completed Code Exams Summary No.

033300 036700 040000 068100 078600 085400 089100 089200 094200 094300 138500 144900 145000.

150900 151000 151100 151200 151300 151400 151500 152200 152210 152220 153600 153700 153800 153900 154000 154100 154200 154300 154400 154500 154600 154700

.154800 156700 158600 Component Identification CH-96-9-F-1 3 CH-97-7-S-07 CH-98-9-S-06 PS-244-VS-1 RC-71-9-S-06 RC-72-4E-S-06 RC-72-7-E-01 RC-104-1-E-01 RC-104-2-PSSP-122A RC-104-2-PSSP-122B RC-53-VS-358-1 DLW-LOOP2-8-HSS-103 DLW-LOOP2-8-HSS-104 INCORE INSTRUMENTS INSTRUMENTATION NOZZLES RC-R-1-C-1 RC-R-1 -C-2 RC-R-1 -C-5 RC-R-1-C-8 RC-R-1 -C-9 RC-R-1-CRDM-SUPP-1 RC-R-1-CRDM-SUPP-2 RC-R-1 -CRDM-SUPP-3 RC-R-1-N-17 RC-R-1-N-171R RC-R-1-N-18 RC-R-1-N-181R RC-R-1-N-19 RC-R-1-N-19IR RC-R-1-N-20 RC-R-1-N-201R RC-R-1-N-21 RC-R-1-N-21 IR RC-R-1-N-22 RC-R-1-N-221R.

RC-R-1-LIG-01 TO 19 RC-R-1-LIG-20 TO 38 RC-R-1-LIG-39 TO 58 Description SOCKET WELD SOCKET WELD SOCKET WELD SNUBBER BRANCH CONN. WELD BRANCH CONN. WELD NOZZLE TO SAFE END NOZZLE TO SAFE END SNUBBER SNUBBER SNUBBER SNUBBER SNUBBER RV HEAD PARTIAL PENETRATION WELDS LOWER HEAD INSTR NOZZLES SHELL TO FLANGE CIRC WELD CIRCUMFERENTIAL WELD CIRCUMFERENTIAL WELD CIRCUMFERENTIAL WELD LOWER HEAD CIRC WELD CRDM SHROUD HOUSING SUPPORT CRDM SHROUD HOUSING SUPPORT CRDM SHROUD HOUSING SUPPORT INLET NOZZLE WELD NOZZLE INSIDE RADIUS OUTLET NOZZLE WELD NOZZLE INSIDE RADIUS INLET NOZZLE WELD NOZZLE INSIDE RADIUS OUTLET NOZZLE WELD NOZZLE INSIDE RADIUS INLET NOZZLE WELD NOZZLE INSIDE RADIUS OUTLET NOZZLE WELD NOZZLE INSIDE RADIUS THREADS IN FLG.

THREADS IN FLG.

THREADS IN FLG.

Class 1

1 1

1 1

1 1

I 1

1 1

1 I

1 1

1 1

1 1

1 1

1' 1

1 1

1 1

1 1

1 1

1.

1 I

Item R1.12 R1.12 R1.12 F01.10N R1.12 R1.12 R1.11 R1.11 F01.10N F01.10N F01.10N F01.10N F01.10N B04.012 B04.013 B01.030 B01.011 B01.011 B01.011 B01.021 F01.40E F01.40E F01.40E B03.090 B03.100 B03.090 B03.100 B03.090 B03.100 B03.090 B03.100 B03.090 B03.100 B03.090 B03. 100 B06.040 B06.040 B06.040 Category R-A R-A R-A F-A R-A R-A R-A R-A F-A F-A F-A F-A F-A B-E B-E B-A B-A B-A B-A B-A F-A F-A F-A B-D B-D B-D B-D B-D B-D B-D B-D B-D B-D B-D B-D B-G-1 B-G-1 B-G-1 Method VT-2, VT-2, VT-2, VT-3, VT-2, VT-2, UT UT VT-3, VT-3, VT-3, VT-3, VT-3, VT-2, VT-2, UT UT UT UT UT VT-3, VT-3, VT-3, UT, UT UT UT UT UT UT UT UT UT UT UT UT UT UT Iso 0246A 0247A 0248A 0244A 0348B 0348D 0348D 0350A 0350A 0350A 0358A 0999B 0999B E-001D E-001D E-001A E-001A E-001A E-001A E-001A E-001A E-001A E-001A E-00 1 B E-001B E-001B E-001B E-001B E-001B E-001B E-001B E-001B E-001B E-001B E-001B E-001B E-001B E-001B Page Al-I

APPENDIX I 1R18 Completed Code Exams Summary 160600 160700 160800 160900 161000 161100 161200 161300 161400 161500 161600 161700 161800 162000 162100 192000 192400 193100 194800 207500 207600 207700 221700 253100 256300 259000 261800 264900 267200 267600 267900 274200 274300 298000 300300 319200 319400 321200 No. Component Identification RC-R-1 -L-3 RC-R-1 -L-4 RC-R-1 -L-6 RC-R-1 -L-7 RC-R-1-L-10 RC-R-1-L-11

.RC-R-1-L-12 RC-R-1-L-13 RC-R-1-L-14 RC-R-1-L-15 RC-R-i-C-16 RC-R-1-LOWER-INT RC-R-I-INT-ATT RC-R-1-ACC-INT RC-R-1-UPPER-INT RC-TK-1-L-3 RC-TK-1 -C-7 RC-TK-1-RADIUS-6 RC-TK-1-HTR PENTS RC-P-1A-A-1 RC-P-1 A-A-2 RC-P-1 A-A-3 MOV-RC-595-B3-25 TO 48 DLW-LOOP1-I-F-01 DLW-LOOP1-7-F-12 DLW-LOOP2-1-F-13 DLW-LOOP2-7-F-24 DLW-LOOP3-1-F-25 DLW-LOOP3-6-F-33 DLW-LOOP3-6-F-34 DLW-LOOP3-7-F-36 RH-23-1-HSS-123 RH-23-1-HSS-124 SI-102-2A-F-1A SI-1 06-1 C-S-02 SI-74-4-HSS-420 SI-74-4-HSS-421 SI-74-5-HSS-422 Description LONGITUDINAL WELD LONGITUDINAL WELD LONGITUDINAL WELD LONGITUDINAL WELD LOWER HEAD MERIDIONAL WELD LOWER HEAD MERIDIONAL WELD LOWER HEAD MERIDIONAL WELD LOWER HEAD MERIDIONAL WELD LOWER HEAD MERIDIONAL WELD LOWER HEAD MERIDIONAL WELD LH CIRCUMFERENTIAL WELD CORE SUPPORT STRUCTURE BEYOND BELTLINE REGION INTERIOR CORE SUPPORT STRUCTURE LONGITUDINAL WELD CIRCUMFERENTIAL WELD NOZZLE INSIDE RADIUS PARTIAL PENETRATION WELDS WELDED SUPPORT WELDED SUPPORT WELDED SUPPORT BOLTING SAFE END WELD SAFE END WELD SAFE END WELD SAFE END WELD SAFE END WELD BUTT WELD BUTT WELD SAFE END WELD SNUBBER SNUBBER SOCKET WELD SOCKET WELD SNUBBER SNUBBER SNUBBER Class 1

1 1

'1 1

1 1

1 1

1 1

I

.1 1

I 1

I 1

1

.1 I

1 I

1 1

1 1

I Item B01.012 B01.012 B01.012 B01.012 B01.022 B01.022 B01.022 B01.022 B01.022 B01.022 B01.021 B13.070 B13.060 B13.010 B13.070 B02.012 B02.011 B03.120 B04.020 B10.030 B10.030 B10.030 B06.21 0 R1.11 R1.11

,R1.11 R1.11 R1.11 R1.11 R1.11 R1.11 F01.10N F01.10N R1.12 R1.12 F01.10N F01.'10N F01.10N Category B-A B-A B-A B-A B-A B-A B-A B-A B-A B-A B-A B-N-3 B-N-2 B-N-1 B-N-3 B-B B-B B-D B-E' B-K B-K B-K B-G-1 R-A R-A R-A R-A R-A R-A R-A R-A F-A F-A R-A R-A F-A F-A F-A Method UT UT UT UT UT UT UT UT UT UT UT VT-3, VT-3, VT-3, VT-3, UT UT VT-2, VT-2 PT PT PT UT UT UT UT UT UT UT UT UT VT-3, VT-3, VT-2, VT-2, VT-3, VT-3, VT-3, Iso E-001C E-001C E-001C E-001C E-001D E-001D E-001D E-001D E-001D E-001D E-001D E-001F E-001F E-001F E-001G E-001P E-001P E-001P E-001P E-001T E-001T E-001T E-002A L-001A L-001A L-002A L-002A L-003A L-003A L-003A L-003A 0107A 0107A 0200A 0200B 0375C 0375C 0375C Page AI-2

APPENDIX I 1 R18 Completed Code Exams Summary No.

329700 332300 371200 371400 371500 381500 397700 420100 420200 422600 422700 425000 425200 436000 440000 443800 470350 496600 509200 512700

.512800 624100 624200 635300 648620 648630 648650 648660 648680 654800 654900 655000 655100 658900 659100 670700 670800 670900 Component Identification SI-73-7-HSS-418 SI-104-1-F-02 WFPD-23-3-HSS-208A WFPD-23-3-HSS-207 WFPD-23-3-HSS-208 P11-G-PSSP-36A SI-82-1-S-01 CH-79-2B-S-07 CH-79-2B-S-1 0 CH-78-2B-S-1 0 CH-78-2B-S-06 CH-77-2B-S-10 CH-77-2B-S-05 CH-69-1 -S-07 CH-70-1-F-1X-A CH-71-1-S-07 CH-131-1-F-4X SI-75-2-A-01 CH-124-10-F-09B SI-81-1A-A-01 SI-81-R-70 SI-16-6-HSS-212A SI-16-6-HSS-212B S1-16-3-S-11 SI-37-1-F-19 SI-37-1-F-23 SI-36-1-F-26 SI-36-1-F-29 S1-145-1-F-01 SI-P-1 B-1 SI-P-1 B-2 SI-P-1 B-3.

SI-P-1 B-4 SHP-56-3-HSS-202 SHP-56-3-HSS-203 SHP-58-7-L-05 SHP-58-7-L-06 SHP-58-7-F-09 Description SNUBBER SOCKET WELD SNUBBER SNUBBER SNUBBER SNUBBER SOCKET WELD SOCKET WELD BRANCH CONN. WELD BRANCH CONN. WELD SOCKET WELD BRANCH CONN. WELD SOCKET WELD PIPE WELD SOCKET WELD PIPE WELD SOCKET WELD WELDED ATTACHMENT SUPPORT SH-230 BRANCH CONN. WELD WELDED ATTACHMENT SUPPORT R-70 SUPPORT SNUBBER SNUBBER BRANCH CONN. WELD SOCKET WELD SOCKET WELD SOCKET WELD SOCKET WELD SOCKET WELD PUMP CASING WELD PUMP CASING WELD PUMP CASING WELD PUMP CASING WELD SNUBBER SNUBBER LONGITUDINAL WELD ALONG ELBOW LONGITUDINAL WELD ALONG ELBOW PIPE WELD Class 1

1 2

2 2

2.

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

Item F01.10N R1.12 F01.20N F01.20N F01.20N F01.20N R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 C03.020 R1.12 C03.020 F01.20R F01.20N F01.20N R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 C06.010 C06.010 C06.01 0 C06.010 F01.20N F01.20N R1.11 R1.11 R1.11 Category F-A R-A F-A F-A F-A F-A R-A R-A R-A R-A R-A R-A R-A R-A.

R-A R-A R-A C-C R-A C-C F-A F-A F-A R-A R-A R-A R-A R-A R-A C-G C-G C-G C-G F-A F-A R-A R-A R-A Method VT-3, VT-2, VT-3, VT-3, VT-3, VT-3, VT-2, VT-2, VT-2, VT-2, VT-2, VT-2, VT-2, VT-2, VT-2, VT-2, VT-2, PT, VT-2, PT, VT-3, VT-3, VT-3, VT-2, VT-2, VT-2, VT-2, VT-2, VT-2, PT, PT, PT PT VT-3, VT-3, UT UT, UT, ISO 0375F 0376A 0062B 0062B 0062B

,01 15A 0192A 0265A 0265A 0265A 0265A 0265A 0265A 0267A 0267A 0267A 0268A 0272A 0273A 0273B 0273B 0109A 0109A 0115A 0360A 0360A 0360A 0360A 0360A E-005C E-005C E-005C E-005C 0001A 0001A 0001C 0001C 0001C Page AI-3

APPENDIX I IR18 Completed Code Exams Summary No.

707500 709200 721000 721100 721710 721720 721730 721740 752700 753300 853100 853200 866200 870400 875500 903997 913870 913885 914850 916200 929500 929600 929700 Component Identification RH-9-1-S-14 RH-12-2-S-09 RH-16-3-HSS-121 RH-16-3-HSS-122 RH-E-1A-N-5 RH-E-1A-N-7 RH-E-1A-N-8 RH-E-1A-N-6 RS-1-3C-HSS-201 RS-1-3C-HSS-238 CC-527-PSSP-300A CC-527-PSSP-300B FC-4-HSS-5A WR-19-HSS-300 WR-9-HSS-313 QS-4-10G-HSS-202 CH-57-1-S-22 CH-123-1 -F-01 CH-149-1-S-22 CH-149-1-S-17 CH-99-1-S-48 CH-100-1-S-42 CH-101-1-S-38 Description BRANCH CONN. WELD BRANCH CONN. WELD SNUBBER SNUBBER RE-INF PLATE TO INLE RE-INF PLATE TO VESc RE-INF PLATE TO VES,1 RE-INF PLATE TO OUTI SNUBBER SNUBBER SNUBBER SNUBBER SNUBBER SNUBBER SNUBBER SNUBBER SOCKET WELD SOCKET WELD SOCKET WELD SOCKET WELD SOCKET WELD SOCKET WELD SOCKET WELD T NOZZLE SEL (INLET) 3EL (OUTLET)

LET NOZZLE Class 2

2 2

2 2

2 2

2 2

2 3

3 3

3 3

2 2

2 2

2 2

2 2

Item R1.12 R1.12 F01.20N F01.20N C02.031 C02.031 C02.031 C02.031 F01.20N F01.20N F01.30N F01.30N F01.30N F01.30N F01.30N F01.20N R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 R1.12 Category R-A R-A F-A F-A C-B C-B C-B C-B F-A F-A F-A F-A F-A F-A F-A F-A R-A R-A R-A R-A R-A R-A R-A Method VT-2, VT-2, VT-3, VT-3, PT, PT PT, PT, VT-3, VT-3, VT-3, VT-3, VT-3, VT-3, VT-3, VT-3, VT-2, VT-2, VT-2, VT-2, VT-2, VT-2, VT-2, Iso 0075A 0075A 0208A 0208A E-004A E-004A E-004A E-004A 0079A 0079A 0285A 0285A 0071A 0067A 0068A 0111A 0170B 1042A 1254A 1254A 1518A 1538A 151 OA Page AI-4

APPENDIX II REPAIR / REPLACEMENT ABSTRACT AND NIS-2 FORMS 7

FORM 1/2-ADM-0801.F02 REV 3 RTL N A4.414-A Form No.

1805 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron, OH 44308
2. Plant.

(ADDRESS)

Beaver Valley Power Station (BVPS)

(NAME)

ShiDninanort. PA 15077 Date 11-13-2007 Sheet 1

of 4

Unit No.

1 Work Order #200209617, P.O. 55104586 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date (ADDRESS)

3. Work Performed By BVPS Construction Service (NAME)

Shippinqport, PA 15077 (ADDRESS)

4. Identification of System Main Steam (Class A)
5. (a) Applicable Construction Code Section Itl 1968 Edition, N/A Addenda, N/A Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity.

1989 (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected.

ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Seral No.

No.

Identtification Built Installed (Yes or No)

Safety Valve Dresser BM-7756 N/A SV-IMS-IOIA 1968 Removed Yes Safety Valve Dresser Flow BY-89642 N/A SV-1MS-IOIA 2003 Installed Yes Control Disc Dresser Flow ADW93 N/A N/A 2006 Installed Yes Control

7. 'Description of Work Replaced valve and inlet studs & nuts. Prior to installation NWS Technologies replaced valve disc.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* E]

Nominal Operating Pressure Z Exempt LI Other E]

Pressure psi Test Temp.

_n F tRecord lst pressure and temperature

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.4114-A FORM NIS-2 (Back)

9. Remarks Code Data Reports attached. The disc oh replacement valve S/N BY-89642 was Applicable Manufacturer's Data Reports to be attached reolaced bv NWS Technolooies. LLC. Reolaced 1-3/8" Studs: P.O. 47020638 / Ht. #K1 32. P.O.

104336-160 / Ht. #13853-C625; Nuts: P.0 45136785 1 Ht.#P366, P.O. 45138286 / Ht. #P421.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Senior Specialist Date November 26 20 07 Owne or

'wnrs Designee, Title20 7

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period V-/

F -

G to

/ 0 -

- - 0 7, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspectoe

,ýýure Commissions

,-:i A,3, National Board, State, Province, and Endorsements Date

,20 0,,

FORM NVR-1 REPORT OF REPAIR R9 REPLACEMENT 01 OF NUCLEAR PRESSURE RELIEF DEVICES 1 Work performed by: NWS Technologies, LLC Purchase Order # 55104586 Rev. 2 131 Venture Boulevard, Spartanburg, SC 29306

2. Work performed for. First Energy Corporation, Beaver Valley Power Station 3/4. Owner - name, address and identification of nuclear power plant:

Beaver Valley Power Station,_

P.O. Box 4. Shippingport, PA 15077

5. a: Repaired pressure relief device:

Main Steam E b: Name of manufacturer. Consolidated / Dresser c: Identifying nos.

safet Valve 3787A RT21 BY89 (type)

(rWs d: Construction Code:

Section III (nametsectionldivision) 842 S/N) 1968 (edition) n/a steam 6"

(NB#)

(service)

(size) n/a n/a (addenda)

(Code Cases(s))

2003 (yr.built)

A code Class)

6. ASME Code Section XI applicable for inservice inspection:
7. ASME Code Section XI used for repairs, replacements:
8. Construction Code used for repairs, replacements:

1989 (edition) 1989 (edition) 1968 (edition) n/a (addenda) n/a (addenda) nra (Code Case(s))

nla (Code Case(s))

n/a n/a (addenda)

(Code Case(s))

9. Design responsibilities: n/a
10. Opening pressure: 1075 psig Set-pressure adjustment made at:

NWS Technologies, LLC using steam

11. Description of work (include name and identifying number of replacement parts):

Disassembled, inspected, lapped and lapped and passivated nozzle seat, replaced disc with pre-oxidized X750 disc, machined disc holder

-(CEAR 07-22), assembled. Certified set-pressure and seat tightness using steam.

12. Remarks: NWS Traveler#: 07-118. New disc s/n: ADW93 CERTIFICATE OF COMPLIANCE I,

Cesar V. Sierra certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacemtn of the pressure relief devices described above conforms to Section XI of the ASME Code and the National Board Inspection Code "VR" and "NR" rules.

National Board Certificate of Authorization No.

632 to use the 'R'R" stamp expires April 3, 2009.

Nat' nal Board Certificate of Authorization No.

81 to use theAR" stampxpires April 9, 2009.

NWS Technologies, LLC Manager, QA Date Repair Organization A,

mpadirep 6"intle CERTIFICATE OF04ISPECTION I.

Charles F. Toegel Jr. holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of North Carolina and employed by Hartford Steam Boiler of CT of Hartford, CT have inspected the repair, modification or replacement described in this report on ;xJ3.-.y,#Pv7 and state that to the best of my knowledge and belief, this repair, modification or replacement has been completed in accordance with Section X1 of the of the ASME Code and the National Board Inspection Code "VR" and "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning this repair, modification or replacement described in this report. Futhermore, neither the undersigned

-nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected it thL inspctign.

7h; 0e -7/

-.1:?,,

aC ioNB

  1. 8462, A,(N, I NC# 1073 I Dk -J

-19 s swawre 7 -

Commuissions (N8 (min endorsements). jurisdiction,& no.)

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR II NUCLEAR PARTS AND APPURTENANCES*

AM R"Wrl*id by the Ptovisons of the AWSE Code, Sectio Not to Exceed Ono Duy's ProducUon ENTICAL III Pg. Iof 2

44 Pres~cr Flow Conb~oI. O~mrfrvc. La. k'wy 3225 ~ US I Marmufaured andrtdned by.

P.O. Boz1430 ~mtxr~i.

dr2~~

71309-1430 2 Mwnsdurd 7c Fist Snan Nuzew 0qwt Co. Route 1I 2 cm. Pcrnn

3. Lcoatin of itaegbion -First Enwrgy, $vdeat OgntriI2 CO. 5etier Ve13e P&Mrr Stdon
4. Ty~a 0S304

&5837 X-M 140 S. ASME Cede SetionftU, DIYLiom 1:

19I68

~

ft

-O~ -A-V

($W)

(dn~-

8 gabdcaod In sowdiang with Cons. -01M. (ON~ 2 oy) lilA ts 7 iksn-afs:

Serd Niiv~be~rs AeUseIn Ueas 0PTSga~lng.

8No.1~c~ee~m)

WAMlh. design thifm s(in.)

MIW 10

&WiDfi~)

_N

9. When applicabe, C~itiViWMod~er Datat Repba mS

'a~dQ rego t~ emd athUis ropot f,167N IAftý Pe1q%-.Vwwi2 ISOT7 WIA 2=08 PWJOyabuli iseW de 9 wA-.

WiA Dab-MIA I.

I..

4 Z KLwVohwwvnWl(ft.&1i.)

WA Put or Appuroafterinc NaftWoa Se9W Nirnber Board ft.

irn Nwner1d Ordor C1)

ADW9I (3)

ADW3__

(4)

ADWV94__

(5)

(7)

(10)

(11)

(12)

(13)

(18)

(21)

(24) 1~l Put at Appustance Natdonal Board 10.ý in MRIVbAMI Orde W)

(28)

(2)"

(20)

(31)

(33)

(34)

,M)

(36)

(37)

(40)

(43)

(44)

(43)

(46)

(47)

(40)

(49)

(50)

I.1-a.

JL 10 DeSiPr Presaue WA vol Tewp MA 7

Hydi*. Te$i preSS Suc,~ewnW

~va

'mdi~aS~tcde, or drmeip nay be mad pxoMa fi)aizeh, 8412 x 11. (2) M 0ntahi(3) d~Ieah w s MmwW atbr~f aMMtalpdfb ro 2350 PS10 at temp. OF 7ft ioni

?Wm 2 W3 n fs DeURepal I

Page 11-2 of 145)

F094M N-2 (Back-Pg. 2 otf -

DW

AOWOI,

'CEflTWNATMO COIF-Slc*,

Desfsg! peeifcallorns ctUIed by WA P.

State WA F49. No WMA Do~nmor~ftldb A"

P EStdte WIA Reg. No.

W CM7MCqAT! OFCWMLIANCA!

we ~Wrf t~at ive sbtimeita made in +Js Modow sm0coeTm end tMa 06 (Vfese)

DImsc VOcfWm 1o "h m183 of c'dsýýUu of toe ASPAE Cc&s, Sedtli' WI CMstn 1, DP ate w o

.J1&al(w t~m.

N-43

!E5=0 oft A-4L ww 4

f.

11%avubm 1. Leorn oNunt tab ori-o D~~te-'rhSIdWW I W1..

.wU 1.*

t.,n:,.a'Th\\

fl JUN~. '23. 20M 1: 3OA.-MI 0SESS.4-V,.,,,

FORM NV-i CERTIFICATE HOLDERS' DATA REPORT FOR PRESSURE OR VACUUM A Required by the Provisions of the ASME Code,Section III, Division I A

Pg. lof 2

/

  • , IDresser Flow Control. Dresser Inc. La. Hwy 3225 @ US Hwy 167 N
1.

M~nufactured and c~tfied by P.O. Box l13OAlexandda. Louisiana 71309-1430 2-Manufactured for irst Energy Corporation P.O. Box 3611 Akron. Ohio 44309-3611 (name anid a4aress of ftxhasw

3.

Location of instaIlatioi First Energy Corporation Beaver Valley Power Station Unit # 2 Shippingport Pennsylvania 150677

4.

Valve 3787A Orifice size 14.18 sq in MNom. Inlet size 6

Outlet size 10"

-O (, 4.

.l tm.I no-)

-I.)

5.

ASME Code.Section III, Division 1:

1968

-NO A. ARTICLE 9(2).

NIA

)a" d an date)..

(dae s)

(Code Ca*eno.)

6. Type Spring 1075 Fixad Sat 2250 at SAT

-F

....*(sq*,

P".-Pl* opaatlS*-*d)

-1

(*-Il ruel~.

(0o.,9l*

Y'rl~ep; (blu'ft US. Fij, irieO)*

7.

Idenlflicatin "8Y89642 N/A 3NC2022 WA 2003 (CetHoW$Midal W(a.)

bCRP) 4dr,'tgno.)

Nate.iNc.)

8.

Control ring settings

! Fixed

9.

Pressure retaining ite.ris:

Seada No. or Identification Marl. Spec..

Includinq Type or Grade Body ADP38 Bonnet or Yoke

ýDfN84 Support Rods

.0022, AD023 Nozzle ADN93 Disk

,D048 Spring Washers V

Adjusting Screws I

Spindle Spring Boilting Other Items YOKE ROD NUT HT # RH99g Flanges 0..R2ie'ring capai'y Z.74.229 LbFl ir Steam M

107

11.

Remarks:

I ASME SA216 GR WCC ASME SA216 GR WCC ASME SAl93 GR B6 ASME SA1B2 GR F316 ASTMA565 GR 616 Tensile Strength 75 ksi 70 ksi 75 ksi 75 ksl 4-5-56 i d*t*

ASME SA194 GR2H overpressum as certifed bythe National Board CERTIFICATION OF DESIGN Design Specification certified y

.Louis.P. Copian P.E. State Cafifomia

" Reg. no.

16001 Design Report certified by D. K Sharma P.E. State Louisiana Reg. no.'

20244:

t I.-CERTIFICATE OF COMPLIANCE We certify that the statements dade in this report are correa d that Ibis vale conforms to the rules for construction of the ASME Code.

Section III. Division 1._.

NV Certificate of Authorization he.

1747 Expires 5/2012004 Dte m1~ A Ln Name

_SEE UINE I Signed 1

)

i

~43~

~. 4 JUN.23.2O~

fl:iA~

tSSSE-VA! VC I

FOIRM NV-1 (BACK--- Pg. 2 of 2

)

Certificate Holder's Serial No.

BY89642

  • CERTIFICATE OF INSPECTION I. the undersigned, holding a valid commission issued by the'National Board of Pressure Vessel Inspectors and the State or Province of LOUISIANA and employedby HSSCT

/of IART-FORo, Cr.

haveinspected the valve descibed in this Data Reporto,

,o d state that. to the best of my knowledge and ef, the Certlfate Holder has constructed thisvalve in accordance with 0AS,E Code.Section III.OivIsion 1.

By signing this certificate, Meither the inspetor nor his emnployer makes any war-nly., expressed or implied, concerning the component described in tis Data Rep, rt. Furtherr eifier the inspector-nor his employer shiall be liable in any manner for any personal injury or property damage or a loss of any kind arising firom ar c ected this inspection-Date 4"z, st ed

~~CmnSI~S 167q~'~3

( insi~~t) tNIL 8d (atnL fndwvdnan4) )arA s atpi ovuyAnd no.1 --

I.

I.

1-

  • 1
  • I.

I

...j k

FORM I/2-ADM-0801.F02 REV 3 RTL 4 A4.414-A Form No.

1806 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron, OH 44308 Date Sheet 11-13-2007 1

of 4

2. Plant (ADDRESS)

Beaver Valley Power Station (BVPS)

(NAME)

Shippinqport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Construction Service (NAME)

Shippincqport, PA 15077 (ADDRESS)

Unit No.

1 Work Order #200209618, P.O. 55104586 Repair/Replacement Organization P.O. No.. Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date

4. Identification of System Main Steam (Class A)
5. (a) Applicable Construction Code Section I1l 1968 Edition, N/A Addenda, N/A Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 (c)

Applicable Section Xl Code Case(s): N/A

6. Identification of Components Corrected.

ASME Removed-Code Name of Name of Manufacturer National Board Other year or Stamped Component Manufacturer Serial No.

No-Identification Built Installed (Yes or No)

Safety Valve Dresser BM-07759 N/A SV-1MS-102A 1968 Removed Yes Safety Valve Dresser Flow BY-89643 N/A SV-1MS-102A 2003 Installed Yes Control Disc Dresser Flow ADZ44 N/A N/A 2007 Installed Yes Control

7. Description of Work Replaced valve and inlet studs & nuts..Prior to installation NWS Technologies replaced valve disc.
8. Tests Conducted:

Hydrostatic* LI Pneumatic* E]

Nominal Operating Pressure [

Exempt E]

Other F1 Pressure psi Test Temp.

o F

'Record test pressure and temperature

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Code Data Reports attached. The disc on replacement valve S/N BY-89643 was Applicable Manufacturer's Data Reports to be attached reolaced by NWS Technologies. LLC. Reolaced 1-3/8" Studs: P.O. 47020638 / Ht. #K1 32. P.O.

47062335 / Ht. #S339: Nuts: P.O. 45138286 / Ht. #P421 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed

_L_

Senior Specialist Date November 26

, 20 07 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

- 1' to

/0

- el t4' 0 2

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the.

examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

inspect.

gnature

,ýW&

Commissions

, J.-

/

L a i

National Board, State, Province, and Endorsements "Date

//-at 7 -

, 20 07

FORM NVR-1 REPORT OF REPAIR MZ REPLACEMENT ~

OF NUCLEAR PRESSURE RELIEF DEVICES

1. Work performed by:

NWS Technologies, LLC Purchase Order # 55104586 Rev. 2 131 Venture Boulevard, Spartanburg, SC 29306

2. Work performed for First Energy Corporation. Beaver Valley Power Station 3/4. Owner - name, address and identification of nuclear power plant Beaver Valley Power Station, P.O. Box 4, Shippingport, PA 15077
5. a: Repaired pressure relief device:

Main Steam,

b: Name of manufacturer.

Consolidated I Dresser c: Identifying nos.

3707RA RT21 BY8964 (type)

(mrs SIN d: Construction Code:

Section III (ntme/section/division) safety Valve

.3 n/a I)

(NBU 1968 n/a (edition)

(adden steam 6"

(service)

(size) n/a nda)

(Code Cases(s))

2003 (yr.built)

A Code Class)

6. ASME Code Section Xl applicable for inservice inspection:
7. ASME Code Section XI used for repairs, replacements:
8. Construction Code used for repairs, replacements:

1989 (edition) 1989 (edition) 1968 (edition) n/a (addenda) n/a (addenda) n/a (addenda) nla (Code Case(s))

n/a (Code Casets))

n/a (Code Case(s))

9. Design responsibilities: n/a
10. Opening pressure: 1085 psig Set-pressure adjustment made at:

NWS Technologies, LLC using steam 11, Description of work (include name and identifying number of replacement parts):

Disassembled, inspected, lapped and lapped and passivated nozzle seat, replaced disc with pre-oxidized X750 disc, replaced disc holder (CEAR 07-23), assembled. Certified set-Vessure and seat lfjhtness using steam.

12. RemarKs: NWS Traveler #: 07-119. New disc s/n: ADZ44 CERTIFICATE OF COMPLIANCE I,

Cesar V. Sierra certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacemtn of the pressure relief devices described above conforms to Section XI of the ASME Code and the National Board Inspection Code 'VR" and "NR" rules.

National Board Certificate of Authorization No.

632 to use the "I: stamp expires April 3, 2009.

National ard Certificate of Authorization No.

81 t use the yr" p/"pires April 9, 2009.

vWp NSTechnologies, LIC

& ejr

'Manager.

GA O"te Repair Organization Autho ad representive Title CERTIFICATE OF INSPECTION I,

Charles F. Toegel Jr.

holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of North Carolina and employed by Hartford Steam Boiler of CT of Hartford, CT have inspected the repair, modification or replacement described in this report on )3,i and state that to the best of my knowledge and belief.

this repair, modification or replacement has been completed in accordance with Section XI of the of the ASME Code and the National Board Inspection Code 'VR" and "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning this repair, modification or replacement described in this report. Futhermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind aristng from or connected th ins pct gp od.

OA i Z.

TSl7t1 "NO#

2, A, N, I NC# 1073 Doi "CoWmm, r 'Issons (NB (mnci endorsements). juridcin&n.

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*.

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg.l of 2

Dresser Flow Control, Dresser Inc. La. Hwy 3225 @ US Hwy 167 N

1. Manufactured aid cetifled by P. O. Box 1430 Alexandria Louisiana 71309-1430

. (name awd a*ddss of NPT Cerlfct Holde)

2. Manufactured for First Energy Nuclear Operating Co. Route 169 Shlpplngport, Pennsylvania 15077 (name w4 ad.3s of purxtw)
3. Location of installation First Enemy Nuclear Ooeratina Co. Beaver Valley Power Station Shiopin*aort. PennsYlvania 15077 (name and addmsn)
4. Type OS304 ASME SBM37 170 KSI N/A

( M no.)

(mat pec no.)

(Wnsfl aeth)

(CMN)

5. ASME Code Section III, Divisloh 1:

1968 None A Vessels Article 9 (rd1n)

(

-da )

(as)

6. Fabricated in accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Dr (Sr)

7. Remarks :

Serial Numbers Are Used In'Lieu Of NPT S-tamoina.

2007 (ombue)

N/A (Cods Cse no.)

ite NIA

8. Nom, thickness (in.)

N/A Min. design thickness (in.)

N/A Dia.lD(ft.&In.)

N/A Length overall ft. &In.).

N/A

9. When applicable, Certificate Holders' Data Reports are attached for each item of this report:.

Part or Appurtenance National Serial Number Board No.

in Numerical Order (1)

ADZ44 V

(2)

ADZ45 (3)

ADZ4-(4)

ADZ47 (5)

(6)

(7)

(9)

(10)

(11)

(12)

(13)

(14)

(15)

(16)

(17)

(18)___________

(19)

(20)

(21)

(22)

(23)

(24)

(25)

Part-or Appurtenance National Serial Number Board No..

rn Numerical Order:.

(26)

(27)

(28)

(29)

(30)

(31)

(32)

(33)

(34)

(35)

(36)

(37)

(38)

(39)

(40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

(50)

10. Design pressure N/A psi Temp.

N/A F.

Hydro. Test pressure 2300 PSIG at temp. F Supl~emental (nformatn in the form of iists. Sketches, or drawings may be u!Wd provided (1) size Is 8-102 x 11, (2) Wormatlon in Items"2 and 3 on this Data ReWor is Induded on each sheet (3) each sheet Is numbered and the number of sheets b rmaded at the top of this fni.

teaye au,

-)

-P FORM N-2 (Eo.k

.Zof 2_f_).

Cartificat*oIdersSedal Nos.

ADZ44 - ADZ47 CERTIFICATION OF DESIGN Design specifications certified by NIA P.E. State

-NIA Reg. No.

N/A Design report-certified by WA P.E. State N/A Reg. No.

N/A CERTIFICATE OF COMPMANCE We ce that the statemeets made In this report are conect and that this (these)

DISC conforms to the rules of constbuct0n of the ASME Code, Section Ii1, Division 1.

NPT Certificate of Authorization No.

N-2434 Ex9ir 5/20W12007 Date 2/

/7 Name SEE UNE 1 Slgnedcýý

ý (NPT CeffUlft Holder)

(saulhord ' epresental

)

CERTIFICATE OF INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boller and Piusum Vessel Inspectors and the State or Province

-of- -LOUISIANA.

and employedy

-HSB CT..............-............

of-HARTFORD"C,-T.

have Inspec~these items described In this Data Repoit on -

A 7

arnd stats tat-to the best of my knowledge and belief, the CeMcate Holder has fabrlcated these paft or appurtenances in with the ASMdE Cofe.Section III, Division 1. Each part listed has been authbrized for stamping on the date shown abov..

By signing.thls certificate, neither Met Inspector nor his e r makes any wamanty, expressed or knpfled concerilng the equipment described In this Oata Repoft. F ore. mth the inspector V:h f

r shal be Wa in any manner for any personal Injury or plrperty damage or loss of any k sri

_rm or commnede Date Signed Commissions

,+(AuftodiNa N-a W-stabor(NaIl

9.

l "dt e

nd ano.)"

Nart.ad. e4 1

a002 1/,3UNZ3U0 O-2:0 9:06A M SJUN. 30. 2004 9:06AM DRESSER-INDUSTRIES NO. 9967 P. 2 "CORRECTED CODE DATA RPORT FORM NV-i CERIFICATE HOLDERS DATA REPORT FOR PRESSURE OR VACUUM RELIEF VALVE8 As Requivrd by the Proviions of the ASME Code,Section III, Division I Pg.lIof,2 -

Dresser Flow Control. Dresser hnc. La. Hwy 3225 Q US Hwy 167 N

i.

Manufactured and cedffied by P.O0. Box 1430 Aexandria, Lbuisiana 71309-1430

2. Mw~ufaired for First Enero Coe~ation P.O0. Box 3611 Akron, Ohio 443093611I

-3. Ln=tlo of insteffilaof First Energy Corporation Beaer Vale Poeqto Lit2Sipqrtgof. Pennsylvania 15077

4. Valv 3707RA iliw size W00 Os In IoNw. hiletsize:

T Ouwetsin 40__ _

Mom) w ksI-

6. ASME Code Section IIt, Division 1:

1968 NO

-A, Aiicte9(21 WA.

(~~cm Vb.)3

6. TMp 1085 33 Sdt

~

22D at 10"..OF (wSzpjMda9x M~w )

(S~e'tpVw.4) bbfi'

).

Osbiwp3 (khi lot hk"b)

7..1endficadofl BY-BgW4 W/A 3NC22 NIlA 12003 0 Ca~dUdelftO.~)

faAi) tdrm-'g M) pjWL94NL)

(yerbjft)

8. Contrwring settings Lower-8 Ncthtz, Upper+ +10 Notcesm
9. Pressure relaining itenms*

Seria No. or Identificabn ADP37 Mart. Spm..

lInudnN Type or Grade ASME SA216 GR WCC Body BonnetorYoke Supojd Rods Nozzle Disk Sprng Washem Ad&us§ Screys Spindle Spring

>Bolting Other Hems Flanges
10.

Refie~ng capacity t1. Remarks:

ADN83 AD024 &AD025 ADN92 ASMESM618RWCC ASfME SA193 GRB86 ASME SAW82GR F316 A'148 ASTM A565 GR 615 Tamia 70 ksi 70 kai

_110 Isi 75 k5i WA WlA 10-13-197

.Idtdam.

AGMESA1I4OR2H Yoke Rod Nut HT #RH99 873,601 Lb/Hr $team 97 overpressure as cerded by the National Board CERTIFICATION OF DESIGN Design Speciflatlon certfied by Louis P. Copian P.E. State Cirnia Reg. no.

16001 Design Report certiffed b'y

0. K. Sharma P.E. Stale Louisana R4g no.

20244 CERTIFICATE OF COMPLIANCE We cerlfy that (he statements made in this report are correct and that this v"ne conforms t the rules for conslnicton of the ASME Code.

Section III, Divisifon 1.

NV Certir, ate of Authoization No.

. 1.747 E*eas 6120r04 Date (A/zil~o' Nafm SEE LINElI Sige

JUN. 30. 2004 9: 06AM ORESSER-INOUSTRIES O96 P.

3 FORM NV.I (BACK,-- Pg. 2 of 2)

Cellcale HoWeS Serial Nio.

3 C ERTIF ICAT E. OF MSP ECT ION

1. the undenuld ~igU adoiso issued by the Natina Boawd of Prewnr Vessel Inspectors and Die State or Proince Of~ LOUISIAA and erhployed by.HSSCT best of my kno~1dgq and bellef the Ceiilficat Holder has wolvactddthis valve 0 keodence with-f ASPE5v
C601,

.ýInqtris cer~a en~

iheiie ue hipd or h~is ernployermukes any wnarraiy.exreaed or implied.wnemning thelcomponet desatied in ibis-Data Report Fur~emws, neifher the inspedtor nor.his. nployer shag be liable in any manner for any _pwwoai icnyq or proparftyidern ear aloss of any Idnd aniskingknox q---tAd hiainspec1Jon.64 Data Signed onisos.,,or 4

4 J

4

FORM l/2-ADM-0801.F02 REV 3 RTL # A4.4t4-A Form No.

1807 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron. OH 44308 Date 11-13-2007 (ADDRESS)

Beaver Valley Power Station (BVPS)

2. Plant (NAME)

Shippinwport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Construction Service (NAME)

Shiooinwort. PA 15077 Sheet 1

of 4

Unit No.

1 Work Order #200209619, P.O. 55104586 Repair/Replacement Organization P.O. No.. Job No. etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date (ADDRESS)

4. Identification of System Main Steam (Class A)
5. (a) Applicable Construction Code Section III 1968 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 (c) Applicable Section XI Code Case(s): N/A
6. Identification of Components Corrected, ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Safety Valve Dresser BM-07762 N/A SV-IMS-103A 1968 Removed Yes Safety Valve Dresser Flow BY-89644 N/A SV-IMS-103A 2003 Installed Yes Control Disc Dresser Flow ADZ47 N/A N/A 2007 Installed Yes Control

7. Description of Work Replaced valve and inlet studs & nuts. Prior to installation NWS Technologies replaced valve disc.
8. Tests Conducted:

Hydrostatic* L]

Pneumatic* LI Nominal Operating Pressure 0 Exempt LI Other nl Pressure psi Test Temp.

2 F

  • Record test pressure and temperature

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Code Data Reports attached. The disc on replacement valve SIN BY-89644 was Applicable Manufacturer's Data Reports to be attached replaced by NWS Technologies, LLC. Replaced 1-3/8" Studs: P.O. 47062488 / Ht. #K369; Nuts: P.O. 45138286/ Ht. #P421.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorizatioon-l.

N/A Expiration Date N/A Signed.*

Li' Senior Specialist Date November 26 20 07 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

ý//

' - 0 (,

to

/ 0 -- Z Y - 0 2

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

inspecjO Signature Commissions r

/

National Boa'rd, State, Pro.ince, and Endorsements Date

//L -)- I.

20 (5__>

FORM NVR-1 REPORT OF REPAIR W-REPLACEMENT OF NUCLEAR PRESSURE RELIEF DEVICES

1. Work performed by: NWS Technologies, LLC Purchase Order# 55104586 Rev. 2 131 Venture Boulevard, Spartanburg, SC 29306
2. Work performed for: First Energy Corporation, Beaver Valley Power Station 3(4. Owner - name, address and identification of nuclear power plant Beaver Valley Power Station, P.O. Box 4, Shippingport, PA 15077
5. a: Repaired pressure relief device:

Main Steam b: Name of manufacturer Consolidated i Dresser c: Identifying nos.

lafety Valve 3707RA RT21 BY89 (type)

(Mn's d: Construction Code:

Section III (name/section/division) 644 S"N) 1968 (edition) n/a (NB*)

nae (adde, steam 6"

(service)

(size) n/a nda)

(Code Cases(s))

2003 (yr.buit)

A Code Class)

6. ASME Code Section X1 applicable for inservice inspection:
7. ASME Code Section XI used for repairs, replacements:
8. Construction Code used for repairs, replacements:

1989 (edition) 1989 (edition) 1968 (edition) n/a n/a (addenda)

(Code Case(s))

n/a n/a (addenda)

(Code Case(s))

n/a n/a (addenda)

(Code Case(s))

9. Design responsibilities: n/a
10. Opening pressure:

1095 psig Set-pressure adjustment made at NWS Technologies, LLC using steam

11. Description of work (indude name and identifying nuwber of reptacernent parts).

Disassembled, inspected, lapped and lapped and passivated nozzle seat, replaced disc with pre-oxidized X750 disc, assembled.

Certified set-pressure and seat tightness using steam.

12. Remarks: NWS Traveler #: 07-120. New disc sin: ADZ47 CERTIFICATE OF COMPLIANCE I.

Cesar V. Sierra certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacemtn of the pressure relief devices described above conforms to Section Xl of the ASME Code and the National Board Inspection Code "VR" and "NR" rules.

National Board Certificate of Authorization No.

632 to use the "VR" stamp expires April 3, 2009.

Nalonalpoard Certificate of Authorization No.

81 to use the R"

pires April 9, 2009.

ý,*

NWS Technologies, LLC_

X Manager, QA Date Repair Organization A

represetive Title CERTIFICATE OF INSPECTION I,

Charles F. Toegel Jr.

holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of North Carolina and employed by Hartford Steam Boiler of CT of Hartford, CT have inspected the repair, modification or replacement described in this report on n and state that to the best of my knowledge and belief, this repair, modification or replacement has been completed in accordance with Section XI of the of the ASME Code and the National Board Inspection Code 'VR" and "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning this repair, modification or replacement described in this report Futhermore, neither the undersigned nor my employer shagl be liable In any manner for any personal injury, property damage or loss of any kind arising from or connte, is I "7/.12'07 1f.4**-7,*]*e' NB#8462, A,N,I NC#1073

°(:fate n~top

  • 'fn-am/1 Commissions (NB (Icn endorsements), jurisdiction.& no.)

If

(Page lub or 14to FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code. Section fil

. Not to Exceed One Day's Production Pg. I of 2

Dresser-Flow Control. Dresser Inc. La. Hwy 3225 @ US Hwy 167 N P. O. Box 1430 Alexandria. Louisiana 71309-1430

1. Manufactured and certified by

-( ame wd addm of NPT Cerenctft HoNeW)

2. Manufactured for First Energy Nuclear Operaing Co. Route 169 Shlpplngport, Pennsylvanla 15077

( n=, Wno addm.n of purdwew

3. Location of installation First Ener Nuclear Opera0 Co. Beaver Valley Power Station Shlpingport, Pennsyvnia 15077
4. Type 0S304 ASME SB837 170 KSI N/A 2007 (er-*,afi.)

(maRnPe, no.)

(W140

..)

(CRN)

(0

)

5. ASME Code Section III, Division 1:

A968 None A Vessels, Article 9 WA (GOn)

(addwid date)

.(d

)

(Code Ce no.)

6. Fabricated in accordance with Const. Spec. ( Div. 2 only)

N/A Revision N/A Date NIA (no)"

7. Remarks:

Serial Numbers Are Used In-Ueu Of NPT Stamping.

8. Nom. thickness(in.)

N/A Mln.deslgnthlckness(In.)

N/A Dia'ID(ft&in.)-

NA-Lengthoverall'(fL&ln.).

N/A

9. When applicable, Certificate Holders' Data Reports are attached for each item of this report:

Part or Appurtenance National Serial Number Board No.

in Numerical Order (1) ADZ44 V

(2)

ADZ45 (3)

,ADZ4 (4)

ADZ47.

(5)(8) _____________

(7)(8) ______ _______

(10)

(12)

(13)

(14)

(15)

(16)

(17)..

(18)

(19)

(21)

(21)

.(22)

(23)

(24)

(25)

Part or Appurtenance National Serial Number Board No.,

in Numerical Order:.

(26)

(27)

(28)*

(29)

(30)

(31)

(32)

(33)

(34)

(35)

(36)

(37)

(38)

(39)...

(40)

(41)

(42)

(43)

(44)

(45)

(46)

(47)

(48)

(49)

.(50)

"F.

Hydro. Test pressure "

2300 PSIG at temp. "F

10. Design pressure N/A psi Temp.

NWA Suppaenmtal Wnfommallon In the form oflts. Sketches, or drawings maybe used prelded (1) sfz Is 8-112 x 1I, (2) Informaion L Il es2 and 3 on this Dt Reo Is Indided on eadc shee (3) each sheet Is mnbered and the numberdsheets Ismeconed at thetop ofs b*.

Page 109 of 145)

FORe N-2 (t

.2o I -)

CGMNý kWesSe.t Mws A0Z44 - AUZ47 CERTIFICATION OF DESIGN Design spedfcations.ceMe, by IA P.E_Stlae NIA Reg. No.

NIA Design report* certified by MA P.E. State NiA Reg. No.

NIA',

CERTIFCATE OF COMPLIANCE We ceiay tat t-4esttmens made Inthis repod reconec and that thisthese)

DISC confoms to the Rules of constuclion of the ASME Code, Sedlon Il1, ODivsion t.

NPT Certifcate of Authorization No.

N-2434 ExpiW1 5

=20Y1Z 7

Date "eName SEE NE I Sg (NT CeflodeK

)

t :CERTIFICATE OF INSPECTION.

I, the undersigned. holding avald commission issued by *tel onalBard of B6ole and PNesisuVessel Inspectors and the Slot o Provirm

.of--OUWtANA andemploydy

  • .SCT".-

Of.

HARTFORD. CT.

have Inspected these Items desscsed In this Data Rapodton -

.and statslesthato the best of my IcnowMedge and belKI the Certfcate Holder haa, tebulcathen i

padst or appurtenams nrAiUiwt teAM edSdo IMl. DiOision

.Each part listed has been authbrkiedfor staio pbu an the date shom above.

By signing hgerfctnetrth spector no hs Makes any warranty. expreseed oir huiopflld, cOnenng the eqWpmnw des~rbod In this Data Ri Ort. Fydhennore. uellier the Insipecor wMal* be Pablo In any manner for any personal Llury ropedy damage or loss of any,ris, fr omor conmu*eted Date Signed

_____Cwmiiiskms________________

d (~4 en(a.n 84 (*,4

  • :f
  • '1

JUN. 23. 2004 11:32AM ISESSIR-VALV NO. 6436

.ORM NV-i CERTIFICATE HOLDERS' DATA REPORT FOR PRESSURE OR VACUUM S

RELIEF VALVES' As Required by the Provisions of the ASME Code,Section III, Division 1 F. 9 Pg.I of 2

/

Dresser Flow Control, Dresser Inc. La. Hwy 3225 @ US Hwy 167 N

1.

Manufact'red and cel ed by P.0. Box 1430Alexand alEouis*ana71309-1430 I.

(nam 3W a,* dr ofNV Ceficaia H.:)

2.

Manufactured for first Energy Corporation P. O. Box 361 1 Akron, Ohio 44309-3611 3as"

,i.*mn =a oPv*r*

we, 3-Location of installatior First Energy COrporation Beaver Valley Power Station Unit# 2 Shippingport, Pennsylvania 15077

4.

Valve 3**RA Orifice sze 16.00 Sq in N0-Inletsize 6'

Outlet size 10" (ii-, l o.*se.-ino.)

li.-

(I-f r):

ASME Code, Secton III, Division 1:

19658 NO A. Article 9 (2)

N/A

.(nn aa E-0 n o,.)o

6.

Type Spring 1095 33-99 Sat.

2250 at 70

'F

7.

Identif*caton B'895644 N/A 3NC2022 N/A 2003 (Ce8.dControri(gettns Lower3 -M m Notes

  • rg M

R0 Notches

.8. :Control ling settings Lower - 8 Notches, Upper + 160 Notches

9.

Pressure retaining itemn:

Serial No. or:

Identification Matl. Spec..

Including Type or Grade ASME SA216 GR WCC ASME SA216 GR WCC Body Sonnet or Yoke Support Rods Nozzie Disk Spring Washers Adjusting Screws Spincde Spring Bolting Other Items FRanges

10.

Relieving capacity

11.

Remarks:

ADP35 AbN82 AD026 & ADOS I ASME SAl93 GR 86 ADN90 A0021 ASME. SA182 GR F316 ASTM A565 GR 616 Tensile

  • Strength 70 ksi 70 ksi 110 ksi 75 ksi N/A-NIA 10-13-1967 (date)
  • I Y~ke Rod Nut HT #-RH99

-I ASME SAI94.GR 2H 8T'3.601 Lb/Hr Steamn 87 (Stemorfti(bw)(0 1J overpressure as certified c,.,the National Board I.

-*1

" "CERTIFICATION OF DESIGN DesignSpeCification certified b' Louis P. Copian "P.E. State California Reg. no.

16001 Design Report certified by *, K Sharma PE..State Louisiana Reg. no.

20244 CERTIFICATE OF COMPLIANCE Vie cerýtify hat the statements njade in this report are correct and that this valve conforms to the rules for construction of the ASME Code.

Section III. Division 1..

NV Certificate of Authorization.to.

1747 Expires 5/20W2004 Date

.-*"4.q- '

Name SEE LINE I Signed.',.

W-1V CelU.C

)

(auftioe r~m-enw:.M I

No. 6430 P. 10 II JUN. 23. 2004 11 :33AM -

OSESSER-VALVE FORM NV-I BACK--Pg.2 of 2_ )

Certifcate Ho-ldes Serial No.

By-89644 CERTIFICATE OF INSPECTION

1. the undersigned, holdi'i a valid commission issued by the National 8oard of Pressure Vessel fnspectors and 'he Stats or Province of LOUISiANA and employed by HSB CT of HARTFORD. CT.

have inspected the valve descibed in this Data Report bn -.-

ý and state that to the best of my knowledge andibelief, the Certificate Holder has.constructad this vajve in accordance with tge ASME Code. Section IlI.0ivision -1.

By signing this certificate, leither the inspector nor his employer make5 any warranty, expressed or implied, concerning the component described in this Data Repbrt. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage oraloss (a ny kind arising froed with thisinspec~on Date Sig ed.

Commission f

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

1808 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

Beaver Valley Power Station (BVPS1

2. Plant (NAME)

Shippincqport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Construction Service (NAME)

Shippinoport, PA 15077 (ADDRESS)

Date 11-07-2007 Sheet 1

of 4

Unit No.

1 Work Order #200209847, P.O. 55104586 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date

4. Identification of System Main Steam (Class A)
5. (a) Applicable Construction Code Section (I1 1968 Edition, N/A Addenda, N/A Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 1989 (c) Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected, ASME Removed.

Code Name of Name of Manufacturer National Board Other year or Stamped Component Manufacturer Serial No.

No.

Identification Built.

Installed (Yes or *No)

Safety Valve Dresser BM-7765 N/A SV-IMS-104A 1968 Removed Yes Safety Valve Dresser Flow BY-89645 N/A SV-IMS-104A 2003 Installed Yes Control Disc Dresser Flow ADZ45 N/A N/A 2007 Installed Yes Control

7. Description of Work Replaced valve and inlet studs & nuts.

Hydrostatic* E]

Pneumatic* LI Nominal Operating Pressure I Exempt LI Other nI Pressure psi Test Temp.

o F

  • Record test pressure and temperature
8. Tests Conducted:

FORM I/2-ADM-080O.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Code Data Reports attached. The disc on replacement valve SIN BY-89645 was Applicable Manufacturer's Data Reports to be attached replaced by NWSTechnologies.LLC. Replaced 1-3/8" Studs: P.O. 47062488 / HI. #P369, P.O.

47082958/ Ht. #P919; Nuts: P.O. 45172981 / HI.#X375.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A nerinnOns sn Expiration Date R Peniorir n~r~inli-t N/A Date November 13

, 20 07 Owner or Owner's Designee, Tille CERTIFICATE OF INSERVICE INSPECTION, 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period V- /.Y

  • 3 f, to J 0 -AY

'3 9

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_Commissions J7-,~-/

A. Ž V

Inspec gnature National Board, State, Province, and Endorsements Date

/_____,20 6?.

  • 1

(Page 71 of 145)

FORM NVR-1 REPORT OF REPAIR 1 REPLACEMENT OF NUCLEAR PRESSURE RELIEF DEVICES

1. Work performed by:

NWS Technologies, LLC Purchase Order # 55104586 Rev. 2 131 Venture Boulevard, Spartanburg, SC 29306

2. Work performed for-.

First Energy Corporation, Beaver Valley Power Station 3(4. Owner - name, address and identification of nuclear power plant:

Beaver Valley Power Station, P.O. Box 4, Shippingport, PA 15077

5. a: Repaired pressure relief device:

Main Steam Safety Valve b: Name of manufacturer Consolidated i Dresser c: Identifying nos.

3707RA RT21 BY89645 nla steam 6"

2003 (type)

(mfr's S/N)

(N8#)

(service)

(size)

(yr.bullt) d: Construction Code:

Section III 198e n/a nla A

ý.(name/section/division)

(edition)

(addenda)

(Code Cases(s))

(Code Class)

6. ASME Code Section XI applicable for inservice inspection:

1989 n/a n/a (edition)

(addenda)

(Code Case(s))

7. ASME Code Section Xi used for repairs, replacements:

1989 n/a nia (edition)

(addenda)

(Code Case(s))

8. Construction Code used for repairs, replacements:

1968 n/a n/a (edition)

(addenda)

(Code Case(s))

9. Design responsibilities:

n/a

10. Opening pressure:

1110psig Set-pressure adjustment made at:

NWS Technologies, LLC using steam

11. Description of work (include name and identifying number of replacement parts):

Disassembled, inspected, lapped and lapped and passivated nozzle seat, replaced disc with pre-oxidized X750 disc, assembled.

Certified set-pressure and seat tightness using steam,

12. Remarks: NWS Traveler #: 07-121. New disc s/n: ADZ45 CERTIFICATE OF COMPLIANCE I,

Cesar V. Sierra certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacemtn of the pressure relief devices described above conforms to Section XA of the ASME Code and the National Board Inspection Code 'VR" and "NR" rules.

National Board Certificate of Authorization No.

632 to use the 'R'R" stamp expires April 3, 2009.

National Board Certificate of Authorization No.

81 to use the xpires April 9, 2009.

NWS Technologies, LLC Manager, QA "t

Repair Organization Au6rized re.mr v

Title CERTIFICATE OF INSPECTIONW I,

Charles F. Toegel Jr.

holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of North Carolina and employed by Hartford Steam Boiler of CT of Hartford, CT have inspected the repair, modification or replacement described in this report on ;ZL 7a*.y u_*land state that to the best of my knowledge and belief, this repair, modification or replacement has been completed in accordance with Section Xl of the of the ASME Code and the National Board Inspection Code 'VR" and "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning this repair, modification or replacement described in this report. Futhermore, neither the undersigned nor my employer shall be liable in any manner for any pe nal injury, property damage or loss of any kind arising from or connected is i specttnP I-,,

f is

,p-t, f &/A NB# #W2, A,NI NC# 107j'3 Date rs S ltucomnmissions (NB (inci endorsements), Jurisdiction,& no.)

(Page 108 of 145)

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES As Required by the Provisions of-the ASME Code.Section III Not to Exceed One Day's Production Pg. I of 2

1. Manufactured and certified by Dresser Flow Control, Dresser Inc. La. Hwy 3225 @ US Hwy 167 N P. O. Bat 1430 Alexandrria Louisiana 71309-1430

' (,,r,,,

a,*sa d

NPT cesofItalat)

2. Manufactured for Firsl Energy Nuclear Operating Co. Route 169 Shlplngpodt Penniyla 15077 (nam Wndad3Sf pUMsweh

)

3. Location of installation FMrt Energy Nuclear Operating Co. Beaver Valley Power Sbke. Shippingpod, Pennsylvania 15077
4. Type OS304 ASME SB637 170 KSI NWA 2007 (fimt

.)

(man s

amo.)

(WC40 r, t)Mom (CRN)

(ePbuft),

5. ASME Code Section IIl;- DMsion 1:

1988 None AVessels Article 9 WA

(.zUon)

(&Uwenadaa)

.(i))

(Coda Cww no.)

8. Fabricated In accordance with Const Spec. (Div. 2 only)

NA Revision VA.A Date

-NIA

7. Remarks:

Serial Numbers Are Used In Lleu Of NPT Stamping.

8. Nom. thickness(in.)

NIA Min. design thlckness(ht)

N/A.

Dla.lD(fLt&in.)

NA Lengthoverall(fL&ln.).

N/A

9. When applicable, Certificate Holders'.0ata Repods are attached for eachi tem of this report:

Part or Appu mlehance

-National Serial Number Board No.

inrNumericalOrder (1),

ADZ44 V

(2)

ADZ45 (3)

_._._,_.ADZ_ __,

(4)

ADZ47 (5)

(8)

(7)

(8)

(9)

(10)

(12)

(13)

(14)

(15)

(16)

(17)

(18)

(19)

(20)

(21) i__

(22) "

(23)

(24)

(25)

Pator Appurtenance National.

"SedalfNumbeýr".

Board No..

In Numerical Order, (26)

(27)

(29)

(32)

(33)

(34)

(35)

(36)

(37)

(38)

(39)

(40)

(41)

(42)

(43)

(44)

(45)

(486)

(47)

(48)

(49)

(50)

10. Design pressure WA psi Temp.

WA

'F.

Hydro. Test pressure """2300 PSIG at temp. F Supbddental Irafonrnain In the fonn of lists. Sketches. orndrawtNs maybeused pmded (1) size 8-11x 11, (2) Inkmnaft hi llms 2 and 3a this Data Repo is induded on each sheet (3) each sheetIs numnbered and the inwiber dsheets Isrecorded at thetop offt lbm.

(Page 109 of 145)

FORM N-2 B ~~ 2 of

~ AZ CERTIFICATION OF DESIGN Design specifications certified by N/A P.E. State M/A Reg-No.

N/A Design report* certified by WA P.E_ State N/A Reg. No.

WA CERTICATE OF COMPLIANCE We ceaiy that the statements made In this repod are correct and tht this (these)

DISC conforms to the rules of constriction of the ASME Code,Section II, DOIsIon 1.

NPT Certfflcat6 of Authoriz&aton No.

N-2434'.%

EM

&20=7 Date 2L ý Namne SEE LINE 1 (T Cca HHwdrl)

CERTIRCATE OF INSPECTION.

I. the undereigned. holding a valid cemmisslon iviued by the National Board of Oder ad Proms Vassel and the State or Pmvnc

.of--LOUIS~I4.;-

and employedby

-HB CT of-. HATFRD.CT.

jiave nipectedeeIems decred tDZataRepton

-,end..sla ttot best of my knmvledge and bele the Cacat Holder ho fabricated those p or apprtenaces i with the Cde. Section fit. DivIsion 1t Each pt listed haes been autw for.stari*g n the date shosn Abow*.

By silnin.s ce.tis a therte Inspedornorhis makes any w anty. resp or Wipld,.oerming the equ~pment decrbed in this Oat. Rdpot.Fst, sa2 r,

=~Ihe he Wispo rShall be Eabe fIn any manner for any personal "mur or pmrpetydageo r

.p a

_or....

loss ay Dae L ~2Z' Au~oha Nciw upozr)(Nati 8d. Cfind sndoftenmaoz)

M etand o. n n.

It

,-4.

FORM NV-i CERTIFICATE HOLDERS' DATA REPORT FOR PRESSURE OR VACUUM RELIEF VALVES'*

As Required by the Provisions of the ASME Code, Section IlI, Division I Pg. I of 2

Dresser Flow Control. O*resser Inc. La. twy 3225 @ US Hwy 167 N

. Manufactured and c fified by P. 0 Box 1430 Alexandria, Louisiana 71309-1430 (2.S WWa aidrfrs O rNV CEr o iPO Holder,)

2.

Manufactu red for List Enerq-y Corporation P. 0, Box 3611 Akzon, Ohio 44309-3511 (Darns "a=PwM*1er)

3.

Location of instalation First Energy.Corporation Beaver Valley Power Station Unit 4 2 Shippingport, Pennsylvania: 15077 I.-

ao~da~drm 4;

Valve 3707RA Orifice size 16.00 Sq in Nim. Inlet size 67 Outlet size I o0 (moe rý ein gou aI (b~(i.J

5.

ASME Code, Secin 'ilLt,.ivision 1:

1968 NO A,"Ntide 9" (

N/A t

(~~edvlrs)

(addenladata) tdilss) -

t CodsC.ýiano.)

6.

Type Spridg 1110 33-100 Sat:L 2250 at

.70 F

7.

Identification E(Y-89645 N/A 3NC2022 NIA 2003 (Cld* (z seW rw.)

(CRNJ

(.dramng no.)

(Ntl Bd, N.o.

8.

Controiring settings

!Lower-B Notches, Upper+ 160 Notches

9.

Pressure retaining items:

Serial No. or Identification Mati. Spec..

Includmg Type or Grade ASME SA216 GR WCC Body Bonnet or Yoke Support Rods Nozzle Disk Spring Washers Adjusting Screws Spindle Spring Bolting Other Items.

Flanges

10.

Relieving capacity

11.

Remarks:

ADP36 AD029 & A0030 ASME SA216 GR WCCF Tensile Strength 70 ksi 70 ksi 110 ks4 75 ksi N/A ASME SA193 OR B6 ADN91 ADP08 Ybike Rod Nut HT #RH99 873.601 Lb/Hr Steam 72 j11n*0rki+"r)(psi)

ASME= SA182GRF316 ASTM A565 OR 616 ASME SA1 94 GR 2H ovarpressure as certified by-the National Board NIA 10-13-1957 (daie)

.1 CERTIFICATION OF DESIGN Design Specification certified by Louis P. Copian P.E.State California Reg. no.

.*001 Design Report certified by D. K Sharma P.E. State Louisiana Reg. no.

20244 CERTIFICATE.OF COMPLIANCE We ceiify that the statements made in this report are correct and that this valve conforms to the rules for constructionrof the ASME Code.

-Section III, Division 1. L.

NV Certificate of Authorzatonl1 1747 Expires 5120/2004 Date 1,

f NreSEE LINEI Signe OL+~

1V Sdr% ____

I Supplern~srit Worm aiofl in the form flists. S ces rdrwns a b sd rv-dP 41t

.t.

FORM NV-1 (BACK--- Pg. 2 of 2

)

Certificate Holder's Serial No.

By-896 45 S1 CERTIFICATE OF INSPECTION I, the undersigned, hodl a valid commission issued by the Naflonal Board of Presure Vessel Inspectors and the State or Province of LOUISIANA and employed by HSBCT of HARTFORD, CT.

have inspected the valve described in this Oata Report on 7k1dW '

. and ptate.hat to the best of my knowledge and belieef the Certificate Holder has constructed this valve in accordance with the AtE Code. Section iU.Division 1.

By signing'his cericate, r either the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in Ibis Data Repdt Furthermore, neither the inspector not his -employer shal be liable in any manner for any personal injury or property damage or a loss if any kind arising I or.

with this inspecon:

sigh Date~(K Ujq~~nd SignedAs

_____stale_______________

.I.

/.

I I.

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

1809 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron, OH 44308 Date Sheet 11-15-2007 1

of 4

(ADDRESS)

Beaver Valley Power Station (BVPS)

2. Plant (NAME)

Shippincport, PA 15077 Unit No.

1 Work Order #200209620, P.O. 55104586 (ADDRESS)

3. Work Performed By BVPS Construction Service (NAME)

Shippincqport, PA 15077 Repair/Replacement Organization P0. No.. Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date (ADDRESS)

4. Identification of System Main Steam (Class A)
5. (a) Applicable Construction Code Section III 1968 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section X1 Utilized for Repair/Replacement Activity 1989 (c) Applicable Section X1 Code Case(s): N/A
6. Identification of Components Corrected, ASME Removed.

Code Name of Name of Manufactarer National Board Other Year or Stamped Component Manufacturer Serial No-No.

Identification Built Installed (Yes or No)

Safety Valve Dresser BM-7768 N/A SV-IMS-105A 1968 Removed Yes Safety Valve Dresser Flow BY-89646 N/A SV-IMS-105A 2003 Installed Yes Control Disc Dresser Flow ADZ46 N/A N/A 2007 Installed Yes Control

7. Description of Work Replaced valve and inlet studs & nuts.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* LI Nominal Operating Pressure 0 Exempt [l Other L]

Pressure psi Test Temp.

o_ F Record test pressure and temperature

FORM l/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Code Data Reports attached. The disc on replacement valve SIN BY-89646 was Applicable Manufacturer's Data Reports to be attached reolaced bv NWS Technoloaies LLC Renlqcr.d 1-3/8" Studs: P.O 47062488 / Ht #P369:

Nuts: P.O. 45172981 / Ht.#X375, P.O. 45138286 / Ht. #P421.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date RSenior Snr.ciolist N/A Date November 26

, 20 07 Sinned O-wner or-ner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

-/

I to

/ 0 -7

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's Sip ature Commissions

_7",

l,1 National Board, State. Province, and Endorsements Date

, 20 0 ý)

Date

,20

FORM NVR-1 REPORT OF REPAIR I& REPLACEMENT 1Z[

OF NUCLEAR PRESSURE RELIEF DEVICES

1. Work performed by: NWS Technologies, LLC Purchase Order # 55104586 Rev. 2 131 Venture Boulevard, Spartanburq, SC 29306
2. Work performed for First Energy Corporation, Beaver Valley Power Station 3/4. Owner - name, address and identification of nuclear power plant Beaver Valley Power Station.

P.O. Box 4, Shippingport, PA 15077

5. a: Repaired pressure relief device:

Main Steam b: Name of manufacturer Consolidated I Dresser c: Identifying nos.

3707RA RT21 BY896 (type)

(rafts,S d: Construction Code:

Section III (name/section/division)

Safety Valve tt46 n/a steam 6"

N)

(NB#)

(service)

(size) 1968 n/a n/a (edition)

(addenda)

(Code Cases(s))

2003 (yr.bullt)

A Code Class)

6. ASME Code Section X1 applicable for inservice inspection:
7. ASME Code Section XA used for repairs, replacements:
8. Construction Code used for repairs, replacements:

1989 (edition) 1989 (edition) 1968 (edition) n/a n/a (addenda)

(Code Case(s))

n/a n/a (addenda)

(Code Case(s))

n/a n/a (addenda)

(Code Case(s))

9. Design responsibilities:

n/a

10. Opening pressure: 1125 psig Set-pressure adjustment made at NWS Technologies, LLC using steam
11. Description of work (include name and identifying number of replacement parts):

Disassembled, inspected.,lapped and lapped and passivated nozzle seat, replaced disc with pre-oxidized X750 disc, assembled.

Certified set-pressure and seat tightness using steam.

12. Remarks: NWS Traveler #: 07-122. New disc s/n: ADZ46 CERTIFICATE OF COMPLIANCE I,

Cesar V. Sierra certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacemtn of the pressure relief devices described above conforms to Section X! of the ASME Code and the National Board Inspection Code "VR" and "NR" rules.

National Board Certificate of Authorization No.

632 to use the"'YR" stamp expires April 3, 2009.

National Board Certificate of Authorization No.

81 lo use the 1!apexpires April 9, 2009.

&I--

7 NWS Technologies, LLC

.a Manager. QA Date Repair Organization Autie repreltive "Ide CERTIFICATE OF INSPECTION I,

Charles F. Toegel Jr.

holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of North Carolina and employed by Hartford Steam Bolter of CT of Hartford, CT have inspected the repair, modification or replacement described in this report on.3 J".y *and state that to the best of my knowledge and belief, this repair, modification or replacement has been completed in accordance with Section XJ of the of the ASME Code and the National Board Inspection Code "VR" and "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning this repair, modification or replacement described in this report. Futhermore, neither the undersigned nor my employer shall be liable in any manner for any personal Injury, property damage or loss of any kind arising from or connected w is specy

/12.2

&1 7.,

,,NB

  1. 8462, A, N, I NC# 1073 I/F lspgwsltwiatuCommissions (N8 (mnd endorsements). jurisdiction,& no.)

%'-Y-Jiwo or

L4D, FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. I of 2
1. Manufactured and certified by Dresser Flow Control, Dresser Inc. La. Hwy 3225 @ US Hwy 167 N P.O. Box 1430 Alexandria, Louisana 71309-1430

-(anime 8nd address CI NpT Ce~rctiICt H1older)

2. Manufactured for rMt Energy Nuclear Operatg Co. Route 169 Shlpplngport. Pennsylvania 15077

( naeard all.y owrSatio h i

t P v)

3. Locatio>n of installation First Energy Nuclear Opertn Co. Beaver Valley Power Sta~lon Shippingpoct, Pennsylvania 15077 (nwnm addmG )
4. Type OS304 ASME SB837 170 KSI N/A
  • .f,,

o)

(anvvspsm.

(teneuU'eaU*)

r CRM)

5. ASME Code Section III, Division 1:

1968 None A Vessels, Article 9 (e Mn)

(addeidadate)

.(*as,)

6.:Fabricated in accordance with Const. Spec. (DIv. 2 only)

N/A Revision N/A Da (m)

7. Remarks :

serial Numbers Are Used ln'Ueu Of NpT"Stanping.

2007 WA (Code C& no.)

lto NIA

8. Nom. thickness (in.)

NIA MIn. design thickness (1in.)

N/A

[la. ID (ft. &in.)

N/A Lengthoverall(fL &in.)-

NIA

9. When applicable, Certificate Holders' Data Reports are attached for eachit.em of this report:

Part orAppurtenance' National Serial Number Board No.

in Numerical Order (1)

ADZ44 V

(2)

ADZ45

.(3)

ADZ46, (4)

A,_DZ47_"_.....___,___

(5)

(8)

(7)

(8)

(9)

(10)

(12)

(13)

(14)

(05)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

Pad-orAppurtenanc*e National Serial Number Board No.ý rn Numerical Order:.

(26)

(27)

(28)

(29)

(30)

(31)

(3 2 )

(33)

(34)

(35)

(36)

(37)

(38)

(39)

(40)

(41)

(42)

(43)

(44)

(45)

(46)

(47) _

(48) _.

(49)

(50)

-i OF.

Hydro. Test pressure "2300 PSIG at temp. OF

10. Design pressure NIA psi Temp.

N/A Supemental (dormatn In tUh bm of f&s. Sketches, ordet sW maybe used pmvded (1) siz Is 8-112 x 1, (2) Infamatn In W,-m2 wid 3 on this Data Reo Is incduded on each sheet. (3) each sheet Is nu m

d r

ed milemnbof sheets Is mcled at the top dthis rm

FORMN-2(seA g.201!.f S-Ce~tJilc~dk~e~s

~u Ho14.s. AD44 - ADZ47 CERTIFICATION OF DESIGN Design specifications cerlified by N/A P.E. Sate

-NIA Reg. No.

N/A Design reportt certified by WA P.F State N/A Reg. No.

WA

{WhenSXG" CERTIFICATE OF COMPLIANCE We oeftly that the sttemenit made In Ms MWp aMt rrect and at this (these)

MISC conforms to the Riles of construction of theASME Code, Section fIt, Division 1.

NPT Certificate of Authorization No.

N-2434 Expi 5MM.

.O 7

Date 21/Z?10 Name SEE UNE ISlni (NPT ce hor)

(aHdaodm)l

)

CERTIFICATE OF INSPECTION 1, the undersigned, holding a vaWl Commission issed byth National Board df Boller and Piussura Vesnel kispecto. and the State or Provbmc

.f LOUIS~-

andemployedby CT.....-

of-HARTFORO-CT.

have Inspected these om is iod*

in this Daa Rept on a

s ttothe Ill, Divson I'." EaWh it ftlted hes been aMthbrtmd for stamp*g oan the date shown above.

By ilgning thi eý ae neither the Inspector nor his makes any warranty, epressed or kuipledoonomlng the equment descrbed In this 6ais fdp§6jt F, liO(,

neier lhe Inspector shal be 1abia In any manner for ary persnal Injury oeporty dame or loss of any ad

-f"rom or connected DateSigned

____________Commission"

FORM NV-I CERTIFICATE HOLDERS' DATA REPORT FOR PRESSURE OR VACUUM RELIEF VALVES' As Required by the Provisions of the ASME Code,Section III, Division I Pg. i of 2

Dresser Flow Control, Dresser Inc-La. Hwy 3225 @ US Hwy 167 N 1:

Manufacturedand'c rifiedby P. O. Box 1430 Alexandria, Louisiana 71309-1430 (2

Wan afcddtm of his Cetnert d

C t Ohdo)

2. Manufactured for First Enemqy Corporation P. 0. Box 36811 Akron, Ohio.44309-3611
3. Localion'ofinstallatio First Energy Corporation Beaver Valley Power Station Unit # 2 Shippingporf Pennsylvania 15077 I!naffe ad oddru )
4.

Valve 37 IRA Odrice size 16.00 Sq In Nbrn. Inlet size 6'

Outlet size 10o

5. ASME Code, Section 11I.

Division 1:

196 NO A,A de9(2)

NIA Odom)

(addet.,adale)

(c0a43)

(CodcaCeln,.

6.

Type

..Spring 1125 1____34I01 Sat.

2250' at 70

=F' (Wln.

pau or-**

,,rt.d) s M I, h,,.

(h Test P..

7. Identfication fYf8%646 NIA 3NC2022 N/A 2003 (cart olderss.aialm.

(CRiI)

(drdw~ingr.

WNLd~.)

~

e~ill~

a. Control ring settings tLower-B Notches; Upper + 160 Notches
9. Pressure-retaining ite7s:I Body Bonnet or Yoke A[

Support Rods A[

Nozzle Disk AX Spring Washers I

Adjusting Screws Spindle Spring Bolting Other I'ems Flanges

10.

Relieving capacity

11.

Remarks:

Serial No. or Identification Mail. Spec.,

Including Type or Grade

)P34

)Nas ASME SA21S GRWCC ASME SA216 GRWCC-

)027 & AD028 ASME SA193 GR B6

)N89 P06 ASME SAi82GRF3IG ASTM A565 GR 616 Tensile Strengthi 70 ksi 70 ksi i10 ksi 75 ksi NIA N/A 10-13-1967 I d) ke Rod Nut HT #RH99 ASME SA194 GR 2H 73,601 Lb/Hr Steam 58 overpressure as certified by-he National Board I

t.

Design Specification certified LouisP.:Copian

.Design Report certfiedby

). K.Sharma 7-/

CERTIFICATION OF DESIGN P.E. State P.E. State California Reg. no, Louisiana Reg. no.

46001 20244 I

CERTIFICATE OF COMPLIANCE We certfy that the statements qade in this report are correct and that this valve conforms to the rules for construction of the ASME Code,

$ection III, Division 1.

NV Certificate of Authorization :o.

1747 Expires 512012004 Date I ot....

Name SEE LINE I-.--

Signed -

j~A NV Ce.**,k oe~

MAK I KAZýUp,"roe*ie ISuerienwilorniation in the ofoo ft.Sweches, rdaiseeD rojrja fil,-ý7 i-$Linv 11

FORM NV.1 (BACK--- Pg. 2 of 2

)

Certificate Holders Serial No.

8y-89646 I-h "di 4

"CERTIFICATE OF INSPECTION

.-._a,-

o c

1, the unde-ie, h din a valid commission issued by the National Board of Pressure Vess-

'er of LOUISt.NA and employed by HSB CT of HARTFORD, CT.

have inspece the valve described in Wis Data Report on

, and state that to the best of my knowledge and belief the Certificate Holder has constructed this valve in accordanfce with the-ASME Code. Section llIlDivision 1.

By se*-hi s

'i;t;iipr his enlployer makes any warranty, expressed or imprfed,.concerninq (he component described in this Data Rep rt Furthermore, neither the inspect*cor his employer shall be liable in any manner for any personal injury or property damage or a loss f any kind arising from or conn,iwith this inspection.

Date Siglaed 16 e 2~ --

commissions L6A7e9> ' {7 4

I A40Koix epsclr*)(Ne.6 ucEta'e B3hroYAdn

.1 I.

.1

  • 1.

[-

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

1822 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C.

(NAME) 76 South Main Street - Akron OH 44308 Date 10/31/2007 Sheet 1

of 1

2. Plant (ADDRESS)

Beaver Valley Power Station (NAME)

ShiDrinODort, PA 15077 Unit No.

1 Work Order #200134005 (ADDRESS)

3. Work Performed By BVPS Construction Service (NAME)

Shippincport, PA 15077 (ADDRESS)

Repair/Replacement Organization P-.0 No., Job No., etc-Type Code.Symbol' Stamp Not Applicable Authorization No.

N/A Expiration Date N/A

4. Identification of System Chilled Water (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1971 Edition, S'71 Addenda, N/A Code Case (b)

Applicable Edition of Section XA Utilized for Repair/Replacement Activity.

1989 (c)

Applicable Section Xl Code Case(s) N-416-2

6. Identification of Components Corrected.

ASME.

Removed.

Code Name of Name of Manufacturer National Board Other year or Stamped Componern Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Valve Crane N/A

. N/A 1AC-339 1976 Removed No Valve Velan 07-003-1 N/A IAC-339 2007 Installed No Pipe Energy & Process N/A N/A Ht #A62935 2006 Installed No

7. Description of Work Replaced valve and Pipe.
8. Tests Conducted:

Hydrostatic* LI Pneumatic* E]

Nominal Operating Pressure [

Exempt I Other EL Pressure psi Test Temp.

o F

  • Record test pressure and temperature

FORM 1/2-ADM-080O.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No,Code Data Report available. No previous NIS-2 Data Reports. Valve was designed to Applicable Manufacturer's Data Reports to be attached ASME B16.34 and API 600.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol' Stamp N/A Signed Expiration Date N/A Senior Specialist Date November 7., 20 -

_07

\\Z:7-Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report'during the period

" (2 to

/0

  • '/

'-R 7

and state that to the best of my knowledge and belief, the Owner has performed examinations and takenwcorrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions P,'

a-National Board, State, Province, and Endorsements tiispect~9rgnature Date

/20-02

, 20 02

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

1846 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron. OH 44308 Date Sheet 10/24/2007 1

of 1

2. Plant (ADDRESS)

Beaver Valley Power Station (BVPS)

(NAME)

Shippinqport, PA 15077 Unit No.

1 (ADDRESS)

3. Work Performed By BVPS Constr.

(NAME)

Shiopinwport, PA 15077 iction Service Work Order #200014451 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date (ADDRESS)

4. Identification of System River Water (03)
5. (a) Applicable Construction Code.

ANSI B31.1 1967 Edition, S'71 Addenda, N/A Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity.

1989 (c) Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected.

ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer

  • Serial No.

No.

Identification Built installed (Yes or No)

Rubber Garlock N/A N/A REJ-IRW-4B 1 1994 Removed No Expansion Joint Rubber Garlock N/A N/A -

REJ-1RW-4B1 2003 Installed No Expansion Joint

7. Description of Work Replaced expansion joint, spacer plate, and inlet/outlet flange studs & nuts.
8. Tests Conducted:

Hydrostatic* El Pneumatic* El Nominal Operating Pressure [

Exempt El Other E]

Pressure psi Test Temp.

-OF

  • Record test pressure and temperature

FORM I/2-ADM-0801.F02 REV 3 RTL 4 A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Previous NIS-2 Data Report No: 703. Replaced Spacer Applicable Manufacturer's Data Reports to be attached Plates: P.O. 45204175 1 Ht. #T6842/6B. P.O. 45163730 1 Ht. #4102172: 1-1/4" Studs: D149199-28.

Ht. #J662. P.O. 101186 / Ht. #PWK: Nuts: P.O. 47030430 / Ht. #A201 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization,-

N/A Expiration Date N/A

/1/:

Signed Senior Specialist Date November26 20 07 L

Owner or"' wner's Designee, Tidle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owner's Report during the period T

¶ to

/

- d I/ - 0 2, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

.-7-,

J-/94

?-3 t(

Inspectpr'aSignature National Board, State, Province, and Endorsements Date

,/0

, 20 6 ;

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

1852 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY

f.

As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron. OH 44308 Date Sheet 10/23/06 (ADDRESS)

Beaver Valley Power Station (BVPS) 1 of 1

1

2. Plant Unit No.

(NAME)

Shippinqport, PA 15077 (ADDRESS)

3. Work Performed By FENOC Maintenance (NAME)

Shippingport, PA 15077 (ADDRESS)

Work Order #200018239 Repair/Replacement Organization P.O. No.., Job No.. etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date

4. Identification of System River Water (Class 3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S71 Addenda, NiA Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity_1989 (c)

Applicable Section Xl Code Case(s): N/A

6. Identification of Components Corrected.

ASME Remnoed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Check Valve C & S Valve 92-2019-06(Q)-I N/A 1RW-106 Corrected No Plate Crane Nuclear D5027 N/A HT# 0631 2006 Installed No Plate Crane Nuclear D5028 N/A HT# 0631 2006 Installed No

7. Description of Work Install Plates in spare valve.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* El Nominal Operating Pressure LI Exempt [

Other LI Pressure psi Test Temp.

' F Record test pressure and temperature

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks NorCode Data Report available. Previous NIS-2 Data Report: 1756, 1413, 1318, 1220, Applicable Manufacturer's Data Reports to be attached 654. Plate PO# 45178744 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed-"&

D ate"J Expiration Date N/A bir Date November 2 20 06 I

Owner or Owner's Designee. Title I

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

/_

- 0 G to

/ / -

G. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inýsp S ignature Commissions

/4 Z3 9 Y National Board. State, Province, and Endorsements Date

/--

2" 20 0 i

FORM l/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

1926 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron, OH 44308 Date Sheet 12/18/2007
2. Plant (ADDRESS)

Beaver Valley Power Station (BVPS) 1 of 1

Unit No.

(NAME)

Shippingport, PA 15077 (ADDRESS)

Work Performed By BVPS Maintenance (NAME)

Shippingport, PA 15077 (ADDRESS)

Work Order #200168313 3.

RepaidReplacement Organization P.O. No.. Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date

4. Identification of System Component Cooling (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1973 Edition, S'73 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity_

1989 (c)

Applicable Section Xl Code Case(s): N/A

6. Identification of Components CorrectedL ASME Removedt Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Idernification Built*

Installed (Yes or No)

Check Valve TRW Mission N/A N/A 1CCR-4 1976 Removed No Check Valve Crane Nuclear B5373 N/A ICCR-4 2007 Installed No

7. Description of Work Replaced valve with spare.
8. Tests Conducted:

Hydrostatic* []

Pneumatic* []

Nominal Operating Pressure [D Exempt LI Other E]

Pressure psi Test Temp.

-_ F

  • Record test pressure and temperature

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. *Year installed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A N/A Expiration Date N/A Signed Date December 20

, 20 07 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period y-I'-0I to

/ 0 -,-

'2 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

,K K A L3 r' National Boird, State, Province, and Endorsements tnspectD Signature Date

, 20 0 Y' Date

,20

~

I -C I

FORM I/2-ADM-080O.F02 REV 3 RTL # A4.414-A Form No.

1933 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron, OH 44308 Date 01/16/2007 Sheet 1

of 2

(ADDRESS)

-Beaver Valley Power Station (BVPS)

2. Plant Unit No.

1 (NAME)

Shippinqport. PA 15077 (ADDRESS)

3. Work Performed By BVPS-Maintenance (NAME)

Shippincport, PA 15077 (ADDRESS)

Work Order #200176406 Repair/Reptacement Organization P.O. No., Job No-, etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code Section III 1977 Edition, S'79 Addenda,

- Code Case (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity.

1989 (c) Applicable Section Xl Code Case(s):

6. Identification of Components Corrected.

ASME Removed.

Code Name of Name of Manaufacturer National Board Other Year or

_ Stamped Component Manufacturer Serial No.

No.

Idtttikation Built Installed (Yes or No)

Check ValVe Crane Valve D0551 N/A IRW-158 Removed Ves Check Valve Crane Nuclear D4670 N/A IRW-158 2006 Installed Yes

7. Description of Work Replaced valve and inlet/outlet flange studs/nuts.
8. Tests Conducted:

Hydrostatic* []

Pneumatic* El Nominal Operating Pressure M Exempt El Other EL Pressure psi Test Temp.

o F

  • Record test pressure and temperature I.N

FORM I/2-ADM-080L.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Code Data Report attached. Replacement 5/8" Studs: P.O. 45183672, Ht. #105C, Nuts:

Applicable Manufacturer's Data Repods to be attached P.O. 45198614, Ht. #X929.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed J Expiration Date N/A Senior Specialist Date February 26

, 20 07 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

-3/

-.3 0

to

(

and state that to-the best of my knowledge and belief; the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this.inspection.

Commissions J-/-

)

, ;' '23 NVy np7 "

Signature National Board, State. Province, and Endorsements Date

-C) r

, 20

_9_

2

(Page 5 of 31)

FORM NPV.-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code,Section III, Division 1 Pg. 1 of 2

1.

Manufacmred and certified by CRANE Nuclear, Inc,. 860 Remington Boulevard. Bolingbrook, IL 60440 (name and adress o NPK Ceraicate He*r)

2.

Manufactured for First Energy Corporation, PO Box 345 Shippingport PA 15077 (name and address dpmxdiase,

3.

Locatio of installation.

Beavew Vaney Nuclear Power Plant Route 168. Ship0naport PA 15077 (name and addess

4. Model No., Series No., or Type K15-CEP Drawing CB02791 Rev.

B CRN WA

5.

ASME Code,Section II. Division 1:

1977 Summer 1979 3

cen-

)

(_addena dale)

(da,)

NIA

.code cae in.)

6.

Pump or valve Duo-Chek Valve Nominal inlet size 3

Outlet size 3

7.

Material:

(a) valve Body SA351 CF8M (b) pump Casting N/A (a)

Cert Holder's Serial No.

D4669 (b)

Nafl Board No.

Bonnet WA Cover N/A (c)

Body/Casing Serial No.

Disk SA351 CF6M Bolting N/A (d)

Bonnet/Cover Serial NO.l Bolting SA479 TP 316 (e)

Disk Serial No.

N/A D4670 N/A D4671 & D4672

-'.ooo/ý Supplemental info matkon in the form of lists. Sketches. or drawings may be used provided (1) size is 8 Y. x 11. (2) infornation in items 1 through 4 on gis Data Report is incklded on each sheet. (3) each sheet is numbered and the number of sheets is recorded at the top of this fonrm This form (E00037) may be obtained from the Order Dept ASME. 22 Law Drive. Box 2300. FaitdekJ. NJ 07007-2300.

(Page 6 of 31)

FORM NPV-1 (Back) -

Pg. 2 of 2 Certificate Holders Serial No-04669 8

Design conditions (pressure Psi

  • F or valve pressure class (temperature) 150.

(1)

9.

Cold workdng pressure 275 Psi at 100"F 10.

11.

Hydrostatic test

'425 Psi.

Disk differential test pressure 305 Psi Remarks:

SO No. 27482-01 PO No. 45170559, Item 00001 Valve Tag: VCI-15X-Q CERTIFICATION OF DESIGN Design Specifications certified by Francis Salmon P.E. State PA Reg. No.

3385-E Design Report certified by N/A P.E. Slate NIA Reg. No.

N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are ofrrect and that this pump or valve conform-s to the rules for construction of the ASME Code.Section III. Division 1.

N Certificate of Authorization No.

Date 05/25/06 Name N-2899 Expires September 24. 2008 Puodtte rewesntaw-~)

Jeromie A-Kurowski. P.E.

CRANE Nuclear. Inc._

(N Qeacawe HGichb "CERTIFICATE OF INSPECTION

'I~h unesgehligavldcmrsinise ytetaoaoar o(Biler and Pressure Vessel Inspectors and the of Kart.. l..*

o rd.........

CT ai inspecte lie pr",

or val.-e.*' des..ed...

... i

.aa.poto 0/5 and state Ihaito the*: bestoi 'my knnldg and belief, teCertifiate Holder has wrsnce Ilis Piamp. or valve, in accordanc with the ASME Code. Section Il, Division 1.

By signing this certificate, neithethte.inspector nfis employer makes any warranty, expressed or irnplied. concerning the Component described in Uris Data Report Fuhermore, neiter the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arsng from or connected with i thisinection.

Date 0525/06 Signed 111903 t~uU~w0!ed e&af OAd. W

.1cnaner) adsure at pmey And Mo)

(1) For manually operated valves ony.

FORM l/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

1988 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner F.E.N.O.C.
  • (NAME) 76 South Main Street - Akron, OH 44308 Date Sheet Unit No.

10/18/2007 (ADDRESS)

Beaver Vallev Power Station 1

of 1

2. Plant (NAME)

Shippingport, PA 15077

'(ADDRESS)

3. Work Performed By BVPS Construction Service ShiDDinaoort. PA 15077 Work Order #200211882 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp Not Applicable Authorization No.

N/A Expiration Date N/A (ADDRESS)

4. Identification of System Recirculation Spray (Class C)
5. (a) Applicable Construction Code Section II1 1968 Edition, W'68 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 (c)

Applicable Section XI Code Case(s) N/A

6. Identification of Components Corrected.

ASME

Removed, Code Name of Name of Manufacturer National Board Other Year or Stamped component Manufacturer Serial No.

No.

Identification Buih Installed (Yes or No)

Heat Industrial 63014 3179 1 RS-E-I A 1971 Corrected Yes Exchanger Processes

7. Description of Work Replaced flange studs & nuts and seal welded new diaphragms.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* []

Nominal Operating Pressure [

Exempt EL Other E]

Pressure psi Test Temp.

° F

'Record test pressure and temperature

FORM I/2-ADMW0801.F02 REV 3 RTL # A4'.414-A FORM NIS-2 (Back)

9. Remarks Pre,¥ious NIS-2 Report Nos: 1818, 1697, 1577, 1417. 1251, 945, 854, 697, 690, 595, 557, Applicable Manufacturer's Data Reports to be attached 435. and 295. CoDv of oriainal Code Data Renort in 1577 Renlaced 33/4" Studs: P.O. 45210736/

Ht. #251 F: Nuts: P.O. 45204172 / 443C.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed Own e

rs O

De slp nee t

Expiration Date N/A Senior Specialist Date November 08, 20 07 te Owner or Owner's Desinnee Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owner's Report during the period o-L/-°/.'

0.o to

/_ 0)

V~.-0,")and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificateneither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report-Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from-or connected with this inspection.

Inspector gqnatureNainloadSttPoncndEorees Commissions

"/8 P4lA F"/4 J/A

_, _Y National Board. State. Province. and Endorsements Date

, 20

.0 ?

Dat 200

FORM l/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

1989 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C.

(NAME) 76 South Main Street - Akron. OH 44308 Date Sheet Unit No.

10/17/2007 1

of 1

1 (ADDRESS)

Beaver Valley Power Station

2. Plant (NAME)

ShipDincwort, PA 15077 (ADDRESS)

3. Work Performed By BVPS Construction Service (NAME)

ShippinQport, PA 15077 Work Order #200211884

  • Repair/Replacement Organization P.O. No., Job No.. etc.

Type Code Symbol Stamp Not Applicable Authorization No.

N/A Expiration Date N/A (ADDRESS)

4. Identification of System Recirculation Spray (Class C)
5. (a) Applicable Construction Code Section III 1968 Edition, W'68 Addenda, N/A CodeCase (b)

Applicable Edition of Section Xl utilized for Repair/Replacement Activity 1989 (c) Applicable Section Xl CodeCase(s) N/A

6. Identification of Components Corrected.

ASME Removed.

Code Nameof Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Heat Industrial 6301-3 3181 IRS-E-IC 1971 Corrected Yes Exchanger Processes

7. Description of Work Replaced flange studs & nuts and seal welded new diaphragms.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* LI Nominal Operating Pressure 0 Exempt LI Other [L Pressure psi Test Temp.

°_ F

  • Record test pressure and temperature

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Previous NIS-2 Report: 1819, 1698, 1578, 1418, 1252, 946, 855, 698, 596, 486, 288, and Applicable Manufacturer's Data Reports to be attached 156. Copy of original Code Data Report in 1578. Replaced 3/4" Studs: P.O. 47145149/ Ht. #OB65; Nuts: P.O. 45204172 / Ht. #443C.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are.correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of horizati N/A Expiration Date N/A Senior Specialist Date November 08, 20 07 V

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid, commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford CT have inspected the components described in this Owner's Report during the period el-/P

- 0 6 to

/ 6 -

( -;'Ind state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the'inspector nor his employer.makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury orproperty damage or a loss of any kind arising from or connected with this inspection.

NatioCommissions

//

Sfta 7

Wrovine an Edre National Board, State. Province, and Endorsements Inspector's ýýature Date 20 07

FORM 1/2-ADM-0801 F02 REV 3 RTL # A4.414-A Form No.

1993' FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner 76 South
2. Plant F.E.N.O.C (NAME)

Main Street - Akron. OH 44308 Date Sheet 10-29-2007 1

of 3

(ADDRESS)

Beaver Valley Power Station (BVPS)

Unit No.

.1 (NAME)

Shippingport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Maintenance (NAME)

Shippingport, PA 15077 (ADDRESS)

Work Order 200200991 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date

4. Identification of System Reactor Coolant (Class A)
5. (a) Applicable Construction Code Section III 1968 Edition, S'68 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 (c) Applicable Section X1 Code Case(s): N/A
6. Identification of Components Corrected.

ASME

Remoaed, Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No).

Relief Valve Target Rock 6

N/A RV-IRC-551C 197-3.

Removed Yes Relief Valve Target Rock 0569C-001-1-4 N/A RV-IRC-551C 2007 Installed Yes

7. Description of Work Replaced relief valve for testing purposes and inlet studs & nuts.
8. Tests Conducted:

Hydrostatic* LI Pneumatic* []

Nominal Operating Pressure [

Exempt LI Other E]

Pressure psi Test Temp.

o_ F

  • Record test pressure and temperature

-0 ok FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Code Data Report attached. Previous NIS-2 Data-Report Nos: 1587, 1141, 594, 313, and Applicable Manufacturer's Data Reports to be attached 262. Replaced 1-3/8" Studs: 47120711 / Ht. #J963, P.O. 47082958 / Ht. #P919, P.O. 45189502 I Ht. #R756, Nuts: P.O. 47120711 / Ht. #S663, P.O. 45172981 / Ht. #X375.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of A orizatio N/A Signed riz Expiration Date N/A Senior Specialist Date November 15

, 20 07 Tit[e CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

'J (9

(

to

/ *

.(-t -

0 7, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

jtYtý -+ LZ,6-Commissions al

,Stae Poic d

rse Nationat Board, State, Province, and Endorsements Inspecto

~gnature Date

__ (______

, 20

_9__

FORM NV-1 CERTIFICATE HOLDERS' DATA REPORT FOR PRESSURE OR VACUUM RELIEF VALVES*

As Required by the Provisions of the ASME Code,Section III, Division 1 Pg. 1 of 3

1.

Manufactured and certified by Target Rock: 1966E Broadhollow Rd.; E. Farmingdale, NY 11735 (name and address of NV Certificate Holder)

2.

Manufactured for First Enermav, Route 168: ShiswinaoortPA (name and address of Purchaser)

3. Location of installation Beaver Valley Porwer Station: Route 168: Shinpinciport. PA (name and address)
4.

Valve 0569C-001-1 Orifice size 2.443 Nom. Inlet size 6

(Model no., series no.)

(in.)

(in.)

Outlet size 6

(in.)

5.

ASME Code,Section III, Division 1:

1968 (edition)

Summer 1968 (addenda date)

A None (class)

(Code Case no.)

6. Type Pilot Operated 2485 120 650°F 3325 at 100°F max.

(spring, pilot or power operated) (set pressure, psig) (blowdown, psi)

(rated temp)

(hydro test,psig,inlet)

7.

Identification 4

(Cert. Holders serial no.)

8.

Control ring settings N/A 0569C-001 Rev. D N/A 2007 (CRN)

(drawing no.)

(Natl'l. Bd. no.)

(year built)

N/A

9.

Pressure retaining items:

Serial No. Or Identification Marl. Spec.

Including Type or Grade Tensile Strength Body Bonnet or Yoke Support Rods Nozzle Disk Spring Washers Adjusting Screws Spindle Spring Bolting Other Items 339 SA351 CF8M 75 ksi 11 SA105 70 ksi 5

SA 564 630 140 ksi See page 2 of 3 See Pame 2 of 3

10. Relieving capacity 345,000 lbs/hr overpressure as certified by the National Board (69C) 10/07/2005 (date) 11..Remarks:

CERTIFICATION OF DESIGN Design Specification certified by F.W. Gardner P.E. State PA Reg. No. 036614-E Design Report certified by Not applicable P.E. State N/A Reg. No.

N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

Date

////0 Name N-1949 Target Rock Expires 12/12/2007 Signed J DeBoni QA Manager (authorized representative)

(Certificate Holder)

  • Supplemental information in form of lists, sketches, or drawings may be used provided (1) size is 8V/ x11, (2 information in items 1 through 4 on this Data Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form (12/SX)

This fitrn (E104)37) mavy be ohbained from the Order Dept..A\\SME. 22 Law Drive. Box 2300. Fairfield. NJ 07 007-2300 REPR INT 0/9)3

FORM NV-1 (Pg. 2of3 )

Certificate Holder's Serial No. 0569C-001-1 s/n 4

1. Manufactured and certified by Target Rock: 1966E Broadhollow Rd.: E. Farmingdale, NY 11735 (name and address of NV Cetificate Holder)
2.

Manufactured for First Enerwv-Route 168: Shpoinqport, PA (name and address of Purchaser)

3. Location of installation Beaver Valley Power Station:Rout 168: Shiovincvrt. PA (name and address)
4.

Valve 0569C-001-1 Orifice size 2-443 Nora. Inlet size 6

(Model no., series no.)

(in.)

(in0)

Outlet size 6

(in.)

SEEa _No.

Material Spec.

Tensile Pressure Retaining item or Including Type Identification or Grade Strength Main Seat 200323-1 26 SA479 304L 70 ksi Pilot Body 7

SA493 75 ksi Bonnet Cap 11 SA105 E-rt L ap 9

8-I 1

.A4...

1U 15 kSl Hex Nut 100-0076 n'a SA194 2H n/a Hex Bult 7-910---r-n/a SA193 125 ksi Stud 206189-2 nla SA193187 125 ksi Stud 206189-1 nta SA193 B7 125 ksi Stud 100482-2 rva SA 193B7 125 0ksi Stud 100482-1 n/a SA193 B7 125 ksi

FORM NV-1 (Pg. 3of3)

Certificate Holder's Serial No. 0569C-001-1 s/n 4

1. Manufactured and certified by Target Rock: 1966E Broadhollow Rd.& E. Farmingqdale, NY 11735 (name and address of NV Certificate Holder)
2. Manufactured for First Enerqy; Route 168: Shippingport. Pa (name and address of Purchaser)
3.

Location of installation Beaver Valley Power Station: Route 168: Shippingqport, PA (name and address)

4. Valve 0569C-001-1 Orifice size 2.443 Nom. Inlet size 6

Outlet size 6

(Model no., series no.)

(in.)

(in.)

(in.)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of New York and employed by OneBeacon America In.urarqe Comany of Boston. MA have inspected the pump, or valve, described in this Data Report on 6

and state that to the best of my knowledge and belief, the Certificate Holder has constructed this 0I*mp, or *alve, in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner ny personal injury or property damage or a loss of any kind arising from or connectd vWith this inspect.

Date_/l *7 Sign e

m 2

,missions (Authorized Ins 71f0Y (Nat'l. Bd.(incl. endorsements) and state or prov. and no.)

k-1.1

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2003 FORM NIS-2 OWNER'S REPORT FOR REPAiRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner F.E.N.O.C Date 10/26/2007 (NAME) 76 South Main Street - Akron. OH 44308 Sheet 1

of 1

2. Plant (ADDRESS)

Beaver Valley Power Station (BVPS)

(NAME)

ShinninODort, PA 15077 Unit No.

1 Work Order #200213863 (ADDRESS)

3. Work Performed By BVPS Maintenance (NAME)

Shippinoport. PA 15077 (ADDRESS)

Repair/Replacement Organization P-.0 No.. Job No., etc.

Type Code Symbol-Stamp N/A Authorization No.

N/A Expiration Date

4. Identification of System Main Steam (Q2)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, N/A Code Case (b)

Applicable Edition of Section X1 Utilized for Repair/Replacement Activity.

1989 (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected.

ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Gate Valve.

Crane Valve N/A N/A I MS-26 1976 Corrected No

7. Description of Work Replaced body/bonnet studs & nuts.
8. Tests Conducted:

Hydrostatic* []

Pneumatic* El Nominal Operating Pressure LI Exempt [

Other EL Pressure psi Test Temp.

° F Record test pressure and temperature

FORM I/2-ADM-080I.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Replaced 7/8" Nuts: P.O. 45161672 / Ht. #217A; Studs:

Applicable Manufacturer's Data Reports to be attached P.O. 47134616 / Ht. #Z660.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type.Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Senior Specialist Date November 2

,20 07 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period G-/

to 0

Y

- 0 7,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor. his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions I,

71,1 F C/

Inspect/"s signature National Board, State, Province, and Endorsements Date

/,2-J--

, 20 0 9

FORM I/2-ADM-0801.F02 Rev. 3 RTL # A4.414-A Form No.

2005 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C.

Date 10/09/07 (NAME) 76 South Main Street - Akron. OH 44308 Sheet 1

of 2

(ADDRESS)

2. Plant Beaver Valley Power Station (NAME)

ShioDineoort. PA 15077 Unit No.

1 Work Order #200207913 (ADDRESS)

RepairlReplacement Organization P.O. No., Job No.- etc,

3. Work Performed By BVPS Maintenance

, (NAME)

Shippincqport, PA 15077 (ADDRESS)

Type Code Symbol Stamp Not Applicable Authorization No.

N/A Expiration Date N/A

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ASME Section III 1977 Edition, S79 Addenda N/A Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 (c) Applicable Section XI Code Case(s) NI__A

6. Identification of Components corrected.

ASME Removed.

Code Name of Name of Manufacturer National Board Other Yeax or

-Stamped Component Manufacturer Serial No.

No.

Identification Buih Installed (Yes or No)

Check Valve Clow Corp 82-2669-02N N/A IRW-159 N/A Removed Yes Check Valve Crane Nuclear D2080 N/A I RW-159 2003 Installed Yes

7. Description of Work Replaced Check Valve.
8. Tests Conducted:

Hydrostatic* LI Pneumatic* 11 Nominal Operating Pressure M Exempt Li Other LI Pressure psi Test Temp.

'F

  • Record test pressure and temperature

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Codb Data Report attached.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed Expiration Date N/A Senior Specialist Date October 19

, 20 07 uwner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period k-

-G.

to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASMEýCode,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

inspecp s Signature Commissions T1 'J/

a ý 14 National Board. State, Province, and Endorsements Date

_/_0 - 2_-)--

20 0)"

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES.

As Required by the Provisions of the ASME Code, Section I11, Division I Pg. 1 of 2

1.

Manufactured and certified by CRANE Nuclear, Inc., 860 Remington Boulevard, Bolingbrook, IL 60440 (name and address of NPT Certificate Holder)

2.

Manufactured for First Energy Corporation, PO Box 345 Shippingport, PA 15077 (name and address of purchaser)

3.

Location of. installation Long Term Storage Facility. Sftippingport Hill Road, Shippingport PA 15077 (name and address)

Rev.

B CRN N/A

4.

Model No., Series No., or Type K15 CEP Drawing

.CB02791

5.. ASME Code,Section III, Division 1:

1977 Summer 1979 3

(edition)

(addenda date)

(class)

N/A (Code Case no.)

3 (in.)

6i Pump or valve Duo-Chek Valve Nominal inlet size 3

(in.).

Outlet size

7.

Material:

(a) valve Body (b) pump Casting (a)

Cert.

Holder's Serial No.

SA351 CF8M (b)

Nat'l Board No.

Bonnet.

WA Cover

()

BodylCasing Serial No.

Disk SA351 CF8M Bolting.

(d)

Bonnet/Cover Serial No.

Bolting SA479 TP 316A (e)

Disk Serial No.

D2080 N/A D2081 N/A D2082 & D2083 Z,

" Supplemental information in the form of lists, sketchesor drawings may be used provided (1)size is 8 % xl i. (2) information in items 1 through 4

.on this Data Report is included on each sheet (3) each sheet is numbered and the.number of sheets is recorded at the top of this form.

This form (E00037) may be obtained from the Order Dept. ASME, 22 Law Drive. Box 2300. Fairfield, NJ 07007-2300.

FORM NPV-1.(Back) --

Pg. 2 of 2 Certificate Holder's Serial No.

02080 8 -ý Design conditions (pressure psi (temperature)

°F or valve pressure class ANSI 150 (1)

9.

Cold working pressure 275 psi at 100"F

10.

Hydrostatic test 425 psi.

Disk. differential test pressure 305 psi 1.1.

Remarks:

PO No. 7087502, Item No. I SO No. 14531-01 Mark No.:

Valve ID: VC-15X-Q HingelStop Pin Retainers Ht. No.: 7105H CERTIFICATION OF DESIGN Design Specifications certified by Francis Salmon P.E. State PA Reg. no.

3385-E Design Report certified by NIA P.E. State NIA Reg. no.

N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1:.

N Certificate of Authorization No.

N-2899 Expires September 24, 2005 Date CRANE Nuclear, Inc.

Signed J

(N Certdkiate Holder)

..,,-(authorizqd r sentatwe) 03/10/03 Name.

/

Jerome A. Kurowski, P.E.

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by.

HSBCT of Hartford, CT have inspected the pump, or valve, descibed in this Data Report on 03/10/03 and state that to the best of my knowledgeand belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied; concerning the component described in this Data Report. Furthermore, neither the inspector, nor his employer shall.be liable in any manner for any personalinjury or property damage or loss of any kind arising from or connected with this inspection.

Date, 03/10/03 Signed omisin Ro(AubIized Nuclear ns or.

Robert Rainey IL 932

  • (Nall 6d. (incl. endorsements) and state or prov. and no.)

(1) For manually operated valves only.

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2013 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C.

(NAME) 76 South Main Street - Akron, OH 44308 Date 10/9/2007 Sheet 1

of 1

(ADDRESS)

Beaver Valley Power Station

2. Plant Unit No.

1 (NAME)

Shippingport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Valve Team (NAME)

Shinninonnrt PA 15077 Work Order # 200205525 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp Not Applicable Authorization No.

N/A Expiration Date N/A (ADDRESS)

4. Identification of System Main Steam (02)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, N/A Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 (c) Applicable Section Xl Code Case(s) N/A

6. Identification of Components Corrected.

ASME Removed.

- Code Nameof Name of Manufacturer National Boaod Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Valve Enertech 11496 N/A -IMS-80 2006 Corrected Yes

7. Description of Work Replaced valve inlet/outlet flange studs and nuts.
8. Tests Conducted:

Hydrostatic* El Pneumatic* El Nominal Operating Pressure EI} Exempt [

Other L1 Pressure psi Test Temp. _

OF

  • Record test pressure and temperature

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Code Data Report attached to NIS-2 Report #1811. Previous NIS-2 Report Nos: 144, 601, Applicable Manufacturer's Data Reports to be attached 1018. 1209. 1406. 1557. 1726. and 1811. Renlaced 3V-Nuts: P.0 45204172 / Ht #443C: Studs:

P.O. 45204172 / Ht. #445C.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed Expiration Date N/A Senior Specialist Date November15, 20 07 U.

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

ý/_/ f

-3 6t to

(

-. '_(-Pand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

-r

/(4

,npo's~o

,, ature National Board, State, Province, and Endorsements Date

!f- (9-

, 20 d ý)

FORM I/2-ADM-0801.F02 REV 3 RTL 4 A4-414-A Form No.

2015 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron, OH 44308 Date Sheet 11/14/2007 (ADDRESS)

Beaver Vallev Power Station IBVPS')

1 of 1

1

2. Plant Unit No.

(NAME)

Shippincqport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Maintenance (NAME)

Shippincqport, PA 15077 1 ---- I'l Work Order #200135694 Repair/Replacement Organization P.O. No., Job No.. etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date

4. Identification of System Reactor Coolant (Class A)
5. (a) Applicable Construction Code Section III 1968 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity, 1989 (c)

Applicable Section Xl Code Case(s): N/A

6. Identification of Components Carected.

ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes mr No)

Pump Westinghouse 3-618J931GOI N/A 1RC-P-IC 1976 Corrected Yes

7. Description of Work Replaced two #1 seal housina bolts.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* LI Nominal Operating Pressure [I Exempt [

Other Ln Pressure psi Test Temp.

_o F

Record test pressure and temperature

FORM I/2-ADM:0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Previous NIS-2 Data Report Nos: 1398 and 914.

Applicable Manufacturer's Data Reports to be attached Replaced bolts : P.O. 109467/ Ht. #95127. serial numbers 11742 and 11743.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that' this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Senior Specialist Date November 26 20 07 Oer's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period C./_ 4"

- 0 (0 to

/

-O -- Y - 0 7, and-state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

_T

/"

,,a F'C National Board, State, Province, and Endorsements Inspector's Siýture Date

,20 (97

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2016 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron, OH 44308 Date Sheet 11/20/2007 1

of 1

(ADDRESS)

Beaver.Valley Power Station (BVPS)

2. Plant

.Unit No.

1 (NAME)

Shinninonort PA 15077 rin-.- -,

ot P-- A 15077...

(ADDRESS)

3. Work Performed By BVPS Maintenance (NAME)

Shippincqport, PA 15077 (ADDRESS)

Work Order #200124376 Repair/Replacement Organization P.O-No., Job No.. etc.

Type Code Symbol Stamp N/A Authorization No.

N/A

'Expiration Date

.4. Identification of System Main Steam (Q2)

5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, N/A Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity

.1989' (c)

Applicable Section Xl Code Case(s): N/A

6. Identification of Components Corrected, ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Seria No-No.

Identification Built itstalled (Yes or No)

Governor Valve Dresser-Rand (Terry T38492 (Turbine)

N/A IMS-464 1976 Corrected No Steam Turbine)

Plug Dresser-Rand N/A N/A N/A 2006 Installed No

7. Description of Work Replaced valve stem/plugq assembly.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* E]

Nominal Operating Pressure El Exempt [

Other LI Pressure psi Test Temp.

_o F

  • Record test pressure and temperature

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Previous NIS-2 Data Report Nos: 1745 and 974.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Senior Specialist Date November 20

,20 07 Owner or Owner s Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 4-'/ to

(-

_.)'

_ o"

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury. or property damage or a loss of any kind arising from or connected with this inspection.

ýS--eý- -/ 41ýY Commissions p./,

00>4 3 *C/

Insipeýý. Signature I National Board, State. Province, and Endorsements Date

/

-_ A

, 20 09

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2017 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C

, (NAME) 76 South Main Street - Akron, OH 44308 Date 10/29/2007 Sheet 1

of 1

(ADDRESS)

Beaver Valley Power Station (BVPS)

2. Plant Unit No.

1 (NAME)

Shippinqport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Maintenance (NAME)

ShioDinooort. PA 15077 Work Order Nos: 200038342 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date (ADDRESS)

4. Identification of System Feedwater (02)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, N/A Code Case (b)

Applicable Edition of Section XI utilized for Repair/Replacement Activity 1989 (c) Applicable Section XI Code Case(s): N/A

6. Identification of Components Conected.

ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No No.

Identification Built Installed (Yes or No)

Turbine Ingersoll-Rand T-36555 N/A IFW-T-2 1972 Corrected No Gland Case Dresser Rand N/A N/A N/A 2007 Installed No

7. Description of Work Replaced gland case assembly.
8. Tests Conducted:

Hydrostatic* LI Pneumatic* E]

Nominal Operating Pressure [

Exempt EL Other EL Pressure psi Test Temp.

OF

  • Record test pressure and temperature

FORM l/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Previous NIS-2 Data Report Nos: 961, and 296. Original Applicable Manufacturer's Data Reports to be attached manufacture was Non-Code, piping is ANSI B31.1.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type CodeSymbol Stamp N/A Certificate of N

N/A Signed Expiration Date N/A Senior Specialist Date November 15

, 20 07 Owner or Owner's Designee. Tite CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owner's Report during the period Z/-

to

/

7 0

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME. Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

J2

,ovso J inspector'Ignature Commissions

/z-,

/z U

F1 National Board, State, Province, and Endorsements Date

/

-17 I

20 0.7

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2018 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron. OH 44308 Date Sheet 11/08/2007 1

of 1

(ADDRESS)

Beaver Valley Power Station (BVPS)

2. Plant Unit No.

1.

(NAME)

Shimoincwort, PA 15077 Work Order #200135497 (ADDRESS)

3. Work Performed By BVPS Maintenance (NAME)

Shippinciport, PA 15077 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date.

(ADDRESS)

4. Identification of System Main Steam (Q2)
5. (a) Applicable Construction Code ANSI B16.5 1968 Edition, N/A Addenda, N/A-Code Case (b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 1989 (C) Applicable Section XI Code Case(s): N/A
6. Identification of Components Corrected.

ASME Remo.ed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial Nd.'

No.

Identification Built Installed (Yes or No)

Check Valve Schutte &

N690563 N/A TV-IMS-I01C.

1976 Corrected No Koerting Disc Flowserve N/A N/A Ht.,#M0419 2004 Installed No

7. Description of Work Replaced-disc..
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* D]

Nominal Operating Pressure El Exempt E3 Other L]

Pressure psi Test Temp.

°F

  • Record test pressure and temperature

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No.Code Data ReDort available. Previous NIS-2 Data Report No: 1609.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of A horization N/A Expiration Date N/A Signed Senior Specialist Date November 13 20 07 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a validcommission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period to 0/

e )

0

, and state that to'the best oftmy knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor hisemployer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions 4

Cf Inspecto National Board. State, Province, and Endorsements Date

, 20 o?

FORM. 1/2-ADMý0801.F02 REV 3 RTL # A4.414-A Form No.

2019 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner F.E.N.O.C.

(NAME) 76 South Main Street - Akron, OH 44308 Date 10/10/07 Sheet 1

of 1

(ADDRESS)

Beaver Valley Power Station

2. Plant Unit No.

1 (NAME)

ShiDoinaoort. PA 15077 Work Order #200138765

3. Work Performed Shin (ADDRESS)

Repair/Replacement Organization P.O. No., Job No-, etc.

By FENCO Maintenance Type Code Symbol Stamp Not Applicable -

(NAME) pinqport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Ide'ntification of System Reactor Plant Component and Neutron Tank Cooling System (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, N/A Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity_

1989 (c)

Applicable Section XI Code Case(s) N/A

6. Identification of Components Corrected.

ASME Removed.

Code Name of Name of Manufacturer National Other Year or Stamped Component Manufacturer SerialNo.

Board Identification Buih Installed (Yes or No)

No.

Expansion Joint Garlock, Inc.

5-3973 N/A REJ-IcC-16B 1995 Removed

'No Expansion Joint Garlock, Inc.

06-1968 N/A REJ-ICC-16B 2006 Installed No

7. Description of Work Replaced 18" Expansion Joint, Studs and Nuts.
8. Tests Conducted:

Hydrostatic* []

Pneumatic* []

Nominal Operating Pressure M Exempt Li Other [I Pressure psi Test Temp.

OF

  • Record test pressure and temperature

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Previous NIS-2 Data Report #634. Replaced 1-1/8" Applicable Manufacturer's Data Reports to be attached Studs: P.O. 47037233 / Ht. #M584. P.O. 7123870 / Ht. #J218: Nuts: P.O. D149199-299 / Ht.
  1. 73265 32-1 RCC. P.O. 45102947 Ht. #TRS CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed -f, Expiration Date N/A Senior Specialist Date October 12

, 20 07 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 4',1 -?

0 (a to

/ 0 -/R - 0 7

,-and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

trspector' gitr Commissions io f/,

te 4 de aE National Board, State, Province, and Endorsements Date

/_/_,_.

20 0 7

FORM I/2-ADM-080I.F02 REV 3 RTL # A4.414-A Form No.

2024 FORM NIS-2 OWNER'SREPORT FOR REPAIRS/REPLACEMENT ACTIVITY

'ý As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron, OH 44308, Date Sheet 11/06/2007 1

of 4

(ADDRESS)

Beaver Valley Power Station (BVPS)

2. Plant Unit No.

1 (NAME)

Shippinqport, PA 15077 Work Order #200200990 (ADDRESS)

3. Work Performed By BVPS Maintenance (NAME)

Shippinqport, PA 15077 (ADDRESS)

Repair/Replacement Organization P.0. No., Job No_. etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date

4. Identification of System Reactor Coolant (Class A)
5. (a) Applicable Construction Code Section III 1968 Edition, S'68 Addenda, N/A Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity.

1989 (c)

Applicable Section Xl Code Case(s): N/A

.6. Identification of Components Conrecded.

ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Relief Valve Target Rock 5

N/A RV-IRC-551A 1973 Removed Yes Relief Valve Target Rock 0569C-001-I-1 N/A, RV-IRC-551A 2005 Installed Yes Main Stem Target Rock 4

N/A N/A 2006 Installed Yes

7. Description of Work Replaced valve with spare for testing purposes. Also replaced inlet studs/nuts.

Targqet Rock replaced main stem prior to installation.

8. Tests Conducted:

Hydrostatic* []

Pneumatic* LI Nominal Operating Pressure M Exempt [

OtherElI Pressure psi Test Temp.

OF

  • Record test pressure and temperature

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Cede Data Reports attached. Previous NIS-2 Data Report Nos: 1740, 1255, and 892. Valve S/N 1 Applicable Manufacturer's Data Reports to be attached was rebuilt by Target Rock under P.O. 55104545 prior to installation and new stem S/N 4 was installed.

Replaced 1-3/8" inlet Nuts: P.O. 47120711 / Ht. # S663. P.O. 45172981 / Ht. #X375. Studs: P.O. 45189502 I Ht. #R756, P.O. 47120711 / Ht. #J9631 P.O. 47082958 / Ht. #P919.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate

.of A

o N/A Expiration Date N/A Signed wn.r??.!.

Body *

.Bonnet or Yoke Support Rods Nozzle Disk Spring Washers

  • Adjusting Screws Spindle

,Spring' Bolting.

-Other Items 1

SA351 CF8M 75 ksi 8

SA105 70 ksi 3

SA 564 630 140 ksi See page 2 of 3 See page 2 of 3

10. Relieving capacity 345,000 lbs/hr overpressure as certified by the National Board (69C) 10/07/2005 (date)
11. Remarks:

CERTIFICATION OF DESIGN Design Specification certified by F.W. Gardner P.E. State PA Reg. No. 036614-E Design Report certified by Not applicable P.E. State N/A Reg. No.

N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

NCertificate of Authorization No.

Date Name N-1949 Taroet Rock Expires 12/12/2007 Signed R. E'. Glazier,1A Manager (authorized representative)

(Certificate Holder)

,Supplemental inormation in -form of -lists, -sketches,2-or-drawingsmaybe used-provided -(-1)- size is 81/2 x 11,-1 (2) information in items 1 through 4 on this Data Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form

.(12/88) This form (E00037) may be obtained from the Order Dept., ASME, 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300.

REPRING 6/93-

FORM NV-1 (Pg. 2 of 3 )

Certificate Holder's Serial No. 0569C-001-1: s/n 1 Taraet Rock: 1966E Broadhollow Rd.- E-Farminadale. NY 11735

1. Manufactured and certified: by
2.

Manufactured for First Ene (name and address of NV Certificate Holder) ray: Route 168: ShiDoinaDort. PA (name and address of Purchaser)

3.

Location of installation Beaver Valley Power Station; Rout 168; Shippincqport, PA (name and address)

4.

Valve 0569C-001-1 Orifice size 2.443 Nom. Inlet size 6

(Model no., series no.)

.(in.)

(in.)

Outlet size 6

(in.)

Serial No.

jMaterial Specn.

Tensile.

Pressure Retaining Item or Including Type Identification or Grade Main Seat 200323-1 25 SA479 304L 70 ksi Pi!ot Body 303839-2 2

SA479 304.

75 ksi Bonnet Cap.

200324-1 8

SA105 70 ksi hnad ap 3UJ3b-1 b

5A419 j316 lb Ksi Hex Nut 100-0076 n/a SA1 94 2H n/a Hex Bult 100501-1 n/a SA193 B7 125 ksi Stud 206189-2

.n/a SA193 B7 125 ksi Stud 206189-1 n/a SA1 93 B7 125 ksi Stud 100482-2 n/a SA193 B7

..125 ksi Stud 100482-1 n/a SA1 93 B7 125 ksi

.FORM NV-1 (Pg.3 of 3)

Certificate Holder's Serial No. 0569C-001-1

-f/,¶ /

Taraet Rock: 1966E Broadhollow Rd.: E. Farminodale. NY 11735

1. Manufactured and certified by (name-and address of NV Certificate Holder) 2.:. Manufactured for First Enerqv; Route 168: Shipoinqport. Pa

.(name and address of Purchaser).

3.. Location of installation Beaver Valley Power Station; Route 168: Shippincqport, PA (name and address).

4.

Valve 0569C-001-1 (Model no., series no.)

Orifice size 2.443 Nom. Inlet size 6

(in.)_

(in.)

Outlet size 6

(in.)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of New York and employed by OneBeacon America Insurance Company of Boston, MA have inspected the pump, or valve, described in this Data Report on IR11,614oo5" and state that to the best of my knowledge and belief, the Certificate Holder has constructed this" purfip, or valve, in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall, be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectio

),

Date _/,____ Signed 7/-commissions A

2________.__,___

(Authorized Ins r)

(Nat'l. Bd.(incl. endorsements) and state or prov. and no.)

ýPage 17 of 65)

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. Iof 2

1. Manufactured and certified by Target Rock* 1966E Broadhollow Rd.: E. Farmingdale, NY 11735 (name and address of NPT Certificate Holder)
2. Manufactured for FirstEnerqy Corporation: Route 168: Shippinaport, PA (name and address of Purchaser)
3. Location of installation Bever Valley Power Station: route 168: Shippingport. PA (name and address)
4. Type 303833-1 SA564 630 140'ksi N/A 2006 (drawing no.)

(mat'l. spec. no.)

(tensile strength)

(CRN)

(year built)

5. ASME Code,Section III, Division 1:

1968 Summer 1968 A

None (edition)

(addenda date)

(class) (Code Case no.)

6. Fabricated in accordance with Const. Spec. (Div. 2 only)

N/A Revision N/A Date N/A (no.)

7. Remarks:

Main Stem Spare part for valve model no. 0569C-001 -1

8. Nom.Thickness (in.) N/A Min. design thickness (in.) N/A Dia. ID (ft & in.)N/A Length overall(ft &in.)N/A
9. When applicable, Certificate Holders' Data Reports are attached for each item of this report:

Part or Appurtenance Serial Number (1) 4,*

(2) 3)

10)Ii (14) 15) 16)

(17)

(18)

(19) 120) 241) 15).

(2).

National Board No.

I.In Numerical Order N/A Part or Appurtenance-Serial Nu-mber Nationall Board No.

In,Numerical Order 0:

10. Design pressure N/A psi. Temp.

N/A

  • F Hydro. Test pressure 3325 psiq at ambient temp.°F (when applicable)
  • Supplemental information in form of lists, sketches, or drawings may be used provided (1) size is 81/2 x 11, (2) information in items 1 through 4 on this Data Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12188) This form (E00040) may be obtained from the Order Dept., ASME, 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300 REPRINT (7/91)

!age id Or bD)

FORM N-2 (BACK - Pg. 2 of 2)

Certificate-Holders Serial Nos.

303833-1 sin 4 CERTIFICATION OF DESIGN Design specifications certified by F. W. Gardner P.E.

(when applicable) r,,;, n ra

.4*

orfrifiarl-hu nnt -

fnif-12hlg P I State PA Reg. No. 03664-E State

~ -

Reg. No...

ý0 V".ýV_

(whenapplicable)

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these)

Part conforms to the rules for construction of the ASME Code, Section IllI Division 1.

-NPT Certificate of Authorization No.

N-1948 Expires 12/12/2007 Date 4ý--i

.Name Sinn.ýý,1_4- _Y___

ThrnAt Rnt~k Tarn Rock (NPT Certificate Holder)

R. E(Glazier,%VA Manager (authorized representative)

CERTIFICATE OF INSPECTION I1' the undersigned,: holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of New York and employed by OneBea~con America InsuranceCo.,

of Boston,,MA..

have inspectedthe pump, or valve, described in this. Data Report on./9,7-22e.,

3

_'and state that to the best of my knowledge and 'belief,-. the Certificate Holder has fbricated these parts or appurtenances in accordance with thteASME Coe: Section II1, Division 1.e Each part listed hasbeen authorized for stamping on the, date shown above..

Bysigning this certificate, neither the inspector norhis employer makes anywarranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector :nor his employer shall be liablelin any manner for any personal injury or property damage or loss of any kind.

arising from or connected withis inspection.

DatA Signe f_

mmissions____

.__Y_______,

(,Authorized~g ctor)

(Natl.. Bd. (incl. endorsements) and state or prov. and no.):

0, 0i

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2025 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C.

(NAME) 76 South Main Street-Akron, OH 44308 Date Sheet Unit No.

10/17/2007 1

of 1

1 (ADDRESS)

Beaver Valley Power Station

2. Plant (NAME)

Shippingport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Maintenance (NAME)

Shippingport, PA 15077 (ADDRESS)

Work Order #200239865 Repair/Replacement Organization P-0. No.. Job No., etc.

Type Code Symbol Stamp Not Applicable Authorization No.

N/A Expiration Date N/A

4. Identification of System Main Steam (Q2)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, N/A Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity.

1989 (c)

Applicable Section Xl Code Case(s) N/A

6. Identification of Components Corrected.

ASME Removed.

Code Name of Name of Manufaclurer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Check Valve Enertech 11075 N/A IMS-19 2001 Corrected Yes

7. Description of Work Replaced flange studs and nuts.
8. Tests Conducted:

Hydrostatic* El Pneumatic* E]

Nominal Operating Pressure 3 Exempt [

Other E]

Pressure psi Test Temp.

°F

  • Record test pressure and temperature

FORM I/2-ADM-080IF02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Previous NIS-2 Report Nos: 1709, 952, 824, 759. 497, 263, and 143. Replaced 3/4/" Studs:

Applicable Manufacturer's Data Reports to be attached P.O. 45187878 / Ht. #153C: Nuts: P.O. 45204172 /tHt. #443C. P.O. 45178058 / Ht. #X510, P.O.

45190667 / Ht. #Z403. Valve is supplied as ASME Section III 1971 E-S'72A and installed in an ANSI B31.1 system.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed S-UJ.

Expiration Date N/A Senior Specialist Date November 14

, 20 07

\\1_

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period t,

to O

ý9.

_and state that to the best of my knowledge and belief, theOwner has performed examinations apnd taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

/'I At-3 V"

Inspecos Signature National Board, State. Province, and Endorsements Date 20 07

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2026 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY S-As Required by the Provisions of the ASME Code Section XI

1. Owner' FirstEnergy Nuclear Operating Company (NAME) 76 S. Main St. Akron, OH 44308 Date Sheet October 24. 2007 (ADDRESS) 1 of 2

Unit 1

2. Plant Beaver Vallev Power Station Unit No.

(NAME)

Route 168, Shippingport, PA 15077 (ADDRESS)

3. Work Performed By Westinghouse ElectricComp.

(NAME) 4350 Northern Pike, Monroeville, PA 15146 (ADDRESS)

ECP 06-0236, WO# 200223096, 097, 102, 194, 195 Repair/Replacement Organization P.O. No.. Job No.. etc.

Type Code Symbol Stamp N/A

  • Authorization No.

Expiration Date N/A N/A

4. Identification of.System Reactor Coolant System (Class 1)
5. (a) Applicable Construction Code (Vessel)Section III 1965 Edition, W 66 Addenda, 1401 Code Case Applicable Construction Code (Piping) ANSI 831.1 1967 Edition, S 71 Addenda, Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 Edition. No Addenda (c)

Applicable Section Xl Code Case(s): N-504-2, N-638-1 (as modified by Relief Request BV1-PZR-01), N-416-2 (not needed)

6. Identification of Components Corrected.

ASME

Removed, Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes o.r No),

Pressurizer Westinghouse 1311 68-50 1RC-TK-1 1971 Corrected Yes Vessel Pressurizer N/A N/A N/A 1976 Corrected No Piping:

Spray 4" RC-72-1502-QI Safety A 6" RC-97-1502.QI Saf*et B

-6".RC-981502-QI Safety C6"RC.99l502ýQI PORV 6"1RC-104-1502-QI0 Weld N/A N/A N/A 2007 Installed No Overlays:

Spray RC-72-E-OL-0I Safety A RC-97-1-OL-01 Safety B RC-98-1 -OL-0I Safety C RC-99-1 -OL-01 PORV RC-104-1-OL-0I

7. Description of Work Full structural weld overlays (Alloy 52M) were applied to the pressurizer spray safety, and relief nozzles, extending from the carbon steel nozzle material to the stainless steel piping. In addition, linear indication near "A" safety nozzle identified by maanetic particle examination was removed via buffing (separated R/R plan attached)
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* E]

Nominal Operating Pressure [A Exempt LI (22)

Other LI Pressure -

psi Test Temp.

°F

  • Record test pressue and temperature

FORM l/2-ADM-0801.FO2 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks F6rm N-1A Manufacturer's Data Report (pressurizer) and R/R Ilans (6) attached.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A E

Signed,.

iLae

)r e

2

,00 xpiration Date N/A Date Q6rv1Ye-& 7

_, 20 07 OwneF or Owner's Designee, Title t~ o o5-yLe

,,J CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler andPressure Vessel Inspectors and the State or Province of P A and employed by /'/x.4 --7"of

//,q k d,

C 7 have inspected the components described in this Owner's Report during the period

'1-1? - l (0 to

/

.0

- 2 0

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or al1oss of any'kind arising from or connected with

-thiinspection.

X L"-,J Commissions

&tI, 9VY- *,

-ro /3/4 Inspect(Signature National Board, State, Province. and Endorsements Date

//0-

?

220

'a 7

64-~

Ja.Apollic ble As"PF, C9d;S. t~ bil S,

i' W466, Case Nos, 140i

).M4 33:

ýTotl Lent W.S.iLs~eld DbIttA LT.

YjtLXjL'.

EfficienJ0Q Gb~i24z~hLIZ~tH.. '

y"'t X.R.1.09

.. -No. of Caui &es 3________

6gs:()IadlSk-216 Gr W&C T..

7M Miatetial SA-2 16 Ct MCC T.S. 7QQflO.

C. rowe Ilbwb"M IctPekic Cosi.I Hm~asowrrtco Flat:

SW*46 to Pas' Crop'. bamm.

gods)

Thckwum 3.46..

46410 Owee Agms Anaft Radius Dbnoiiie Momwe a orcoal Lo 3.13

-1

-We__

.. L~.>__

(b) laugm

_AJ.L

-am

-=c____..36L.__

vf Weelab&,,b~~

Other iasteata 044_ria.

NP0c.Xe.

T-S. vzciase Nmri AtivoulS.te a~ead-20 7 ýzce fecmai NizyMpchlz)sl

~

t~

Test dAi9...

~485 psi a maz.tems'.134 F. ax ueW.

of

  • 10.

OF.

Comb'-atioo) Press 3106:

_A Sakty be Relief valve outiets: ?Jumbeca...

3Si1ze 6" 1'inUprHa

9. Nozzales:

11Vio O"

~

R* 1'1frevams~t blow 02.".D044a)

X01-v Dm.osi*

Ty".

Maeil Ticrs atelt Atach Surge 114".00 Weld End SA-216 1.5S-6 Srray 1

4.00 Weld End -Gr TCC

.53 Gr lic

10. iosPmcioe ulsoics, No.

1 Size 16" Lct-_

UppRer R1ead Opesimss: Haiwbsoles. No._____

Size_____

Location__________________

7%-"r~dd, No.

______Sim_______

Locairon____

&I. suprs Shr Yes Lugs Legs-Ochree A t ac he r (T#.* 9#No Muuy (wIc alee is OW)

12. Rtsarks: -The primary function of thi* vessel is to 3truif anrd maintain operrn~g.

50 Rt Rrjuef tt-ae~

inn -

hnLthbe pzr ary cool r

Lntwiumsurv anld limit-Rrcssmre varizAtica durin-thý, ftvltiaL trransent 'hfox-n-f fjr-res oie to the reagtor control system,.

W'iot dkactrpiggi of purpose gj %&# vousel-S.al C60ScM.

u etw P....kt e-Tr

.at SList och.. itcrmal or vittomol p~er*iow with eolneldept tonpet.Kurw whe.n 8pvIcaL-!.ý Wecfn~f h 161teStum ctsmade in this report ate coffect &ad that all details of material dý:_Ign, c'nstructon, andi TR~s4Vnii t5 th 71 WI&E Code 17Tcs vk~etJ:e-v 4 -S ccrtion ].11 ma_____I_

signed lies ting-house Elicetr

-,jr~~LQ y

t certirkat of Auchozization Expires N-1 22 April-I10. 19,72_____________

CERTIIFICATION OF DESIGN Deo tn blommis.io" on file ftt Wes LirA:h us v r I Lcctr flr__

Lox U nnoTha r.-, r1l-,i _qisrn,Tziam=r-loid Sato&*.a.61 7*1. Fr.p"? an Mv at A1 _-s Lig fL'tonJJLE I ccLri Corza tian Tapa Sies.a o.nckicotivreo ceritilird by

~Ato-vic lPo'i-r D)i vijsoti p~i 0~om~j.I.

r.4ý Not.-L:

CER(TIFICATEL OF S11011 iNSPLUCH0.

VtSSEL MAD BY._~~~v

~e

FORM I/2-ADM:0801.F02 REV 3 RTL # A4.414-A Form No.

2027 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron, OH 44308 Date 11/05/2007 Sheet 1

of 1

(ADDRESS)

Beaver Vallev Power Station (BVPS,

2. Plant Unit No.

1 (NAME)

Shippinqport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Maintenance (NAME)

Shippingport, PA 15077 (ADDRESS)

Work Order #200207490 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI 831.1 1967 Edition.

S'71 Addenda, N/A Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 1989 (c) Applicable Section Xl Code Case(s): N/A

6. Identification of Components Corrected, ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Bul Installed.

(Yes or No)

Check Valve C & S Valve 89-0929-01(Q)-)l N/A IRW-106 1989 Corrected No

7. Description of Work Replaced valve inletloutlet flange studs & nuts.
8. Tests Conducted:

Hydrostatic* ED Pneumatic* E]

Nominal Operating Pressure EL Exempt M Other L]

Pressure psi Test Temp.

O F Record test pressure and temperature

FORM I/2-ADM-080LF02 REV 3 RTL 4 A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available*. Previous NIS-2 Data Report Nos: 1756, 1220, and 654.

Applicable Manufacturer's Data Reports to be attached Valve was manufactured to ANSI B31.1 19731F *nd R18 34 19RF*1 R*.nlIcned 1-1/4" Stud.9, P0("

47303 was Han.........P..o. ANSI.1...1.9..

H....

B.16...

Nus Eep.O. 4708 53/4" H.....P..

47030430 / Ht. #K339, P.O. D149199-288 / Ht. #844'13-QSA; Nuts: P.O. 47048563 /Ht; #A201.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME, Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authonzation No.

N/A Expiration Date N/A Senior Specialist Date November 7 20 07 Ownett~Oner' Desgnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the perod to

/t 2.

.. iV

  • "?,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code;Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's S ture Commissions

-,r, Ji

/0'+ -?L YV/

National Board; State, Province, and Endorsements Datel

, 20 0 '?

Date

.20

~Z

FORM I/2-ADM-080l.F02 REV 3 RTL # A4.414-A Form No.

2028 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C:

(NAME) 76 South Main Street - Akron, OH 44308 Date Sheet Unit No.

10/10/07 1

of 2

1 (ADDRESS)

Beaver Valley Power Station

2. Plant (NAME)

Shinnincinnrt PA 1F5077 Work Order #200205788 Shinninnnort PA 15077 3.

(ADDRESS)

Repair/Replacement Organization P.O. No., Job No., etc.

Work Performed By BVPS Maintenance Type Code Symbol Stamp Not Applicable (NAME)

Shippinqport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A Identification of Svstem Reactor Plant Comoonent (Q3*

4.

5. (a) Applicable Construction Code

, ASME VIII 1968 Edition, W'68 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 1989 (c) - Applicable Section Xl Code Case(s) N/A

6. Identification of Components Corrected.

ASME Removed.

-Code Name of Name of Manufacturer National Other Year or

. Stamped Component Manufacturer Serial No.

Board Identification Built Installed (Yes or No)

No.

Channel Cover Henry Vogt 18649 11792 1CC-E-1A 1971 Corrected Yes t

I I

7. Description 01 VVo[K - Kepired Grrianel Uover & replaced btuds and N'uts.

8.. Tests Conducted:

Hydrostatic* []

Pneumatic* El Nominal Operating Pressure M Exempt L]

Other LI Pressure psi Test Temp.

o F

  • Record test pressure and temperature

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Code Data Report attached. No previous NIS-2 Data Report. PA Serial Number 434589.

Applicable Manufacturer's Data Reports to be attached Replaced %" Studs: P.O. 45177853 / Ht. #Z1 57: Nuts: P.O. 45178058 / Ht. #X510.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

Signed N/A Expiration Date N/A Senior Specialist Date October 22

, 20 07 S

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of.Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected:the components described in this Owner's Report during the period 0./3/ 0 to A

)

  • ,3 - C

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XA.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer

'shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

lns ignature Commissions Boar/,

K tate, ProPin'e, an

?yr National Board, State. Province, and Endorsements Date

/ to -

_ -2 20 t 7

4b~~k~~O6.Ufltt~ ~ ~~- b.

r'uie Ii it! P rot i-siw~.n (Erif Iý IV F!.de Ilue.Sc of vID

~.

Mianufawrur.l 11 Vot Wcn~

Winte CMia~y f l-anf ac t u,. o r V e -. I

( a k u u k-r ~ l r

- s t ar.

1.s S l a t -

s t I u

ltams%

qU'r i-a!.w e operv as lngeilr.as

'i1~10

%o I

am9h he..,

(itawn in-I toac~ lie co-ee-o vigl wall-v.

HOwltvaC~atix-7Ah,jfs p

(

1ateraah D0.PP t

JU.

q R~~

.T..

quoh Secti onedflk No

\\h-,4..

7~r4..a III:r iLeWs-~b a

ae

-t~.

ib:- Ma

'ri al*-

t

!C

__d~~~f

.c.

R'

-le R

l-Xý

,C-t..4

!;IAN OL

'ý!i t'd!

s. r4ý ors MU I.

Thccts

_.2&

o ae\\tm.t!.7!.

.Tp Srl i~~Te~

-&wl C

.reI. -,

3 1:,v~

Z ~

U Items IZrcl It~

___,-IEli]

  • Se MPIJ om.tcA Mtokj-..

-i 4....

It, T.,S

.1.,.

-- A~~o~d or aT tIatn CoeJ~.

SY A-'

NIS Log T)

Fl it~

~ ~

Wtadet Hwntrf'0 i.I Earthdttt~ta..

allowablec watekainc pres.75ý jdtia

~s ut~.JQ

~

us.ttti Z

S-.Yi.'....a3 Ia.

Irt-ret hc~osatat fa p

ctm tccd for all es l'

I"I"t appi; al'tt..

16a. SA F I. n, V A 1.' %11 0 TL ETT iu Nmb~er _

e-ct

'uat'p Shell Vatcrij11..9_

I

_3i.

-Cig A02 6O

~

She!

Watr-I.

.Shell Drajnr...,___

1

-~~j II inlet Channgel. WaeIlt1

.3 Nozzle SA -106 -B E.iyUI Inlet Cha=,LYo~

n.

L--.-~21D Al~-2

~Q)

Outlet Ciap_

'ater._ltlet-J.

1.3" iRozzleL_..

S& 106 I!L_ _R t

Lc c~itei ~nneE~ta L.

j~t IIIt II It outlettt9...

e..-

~

s.a-tc

,ct-n.

1 as.r' aat-a at thee j

I-r. :

1 a

;ilvý',,Q JIV.

1 j5.-:,

Itt

_______size I,

Loargon______________

lllt.NING.Si IIlandhsiles,.No.

Siz

,SPgwort R 0 1(1 I.JiKS-:..-,rJMar-pp-,rtg(glnet E)gh~ne No.1_

order No..~ Joý:. dr4er No..

Y1M 1ltemi CC-E1A

  • Cbjt~j id ofeah ube s eet.is. c1ad Id~th 38 Lved&dep6s

/

~

4i nc re asing tcaubel 8be dt.thifea to_-

___08__

L____

(Arse

-ifisi.n i plat'oe of Itw. iessel. as Air Tank. Afl.. C-i1-..

lairk-.'d Csriktse. It,-. Stall controla Of -cart P-ct,1 War ccitify that thi, statemnts made in thii report we Cotrect and thast all detail. of Jesigri nsatcial. caniatru~icalin. and

... nian shsip ot thissos so 1 conform to the Aý%ll. (.tode t.ir I attied Pressure Vessels..

I lir-A I.16.....

t.

-72

-ila Itne INRLYO 0,a I

~

L

~

I.eruifictate of Authisrgzati,,, I- %prtrs

_-D~eember 3L~1.2 ~Q E

I'iERTli(FICAT.E Of' SHOP INS.I' IIT N

VESE M

ýý chi.ne Co.0

'at-

-. _RV-I

`ii-

.ky

-- the ua valid coission issued by TheNational Boyfeo Boiler and Pres.sue Vessel I* spec-ovs and-o" lbe State or 3ro nce.

1W..

Dd. and employed IaEm _

.rs tjonin'*Fclal Hfl~iAlm'nn Th nfre.% dX.

have inspected the pressure vesse! described in this manufacturer's data report n

Anril23, 1971.. and stare that to the

_Ast of vs knowledge and belief, the manufac-tirer has cntSlrurcted this proasswe.es.e-..l accoirdance asth th. applicable sections Ai the ASkE Bonilp and Pressure Vessel

.y S ningu.g this cerltficate neither -he Inspector nor his emplover makes any warranty expreszaed

.or implied; concerning the 1jessui Yesael, &desctibed in th~i m:taufacturer's da84.teqort" Furthermore. neither the, Inspector nor'his reciplayer shall be. liabli.

any maid.fEo, lni

ieida, Iajr¥.'Of propery dam*e br a loss of "Y -kd rising otn dtloit..

Commissions N._-_1_

- naip-..or N

S1 Psurr-S n

ai a

N6.

Pnnms kwian I

L Ji. (fit inJ. £ zne4 a

_;:=.isin issue'f by the National Board 31 B-i!er 6ntd Pressuris Vessel Inspectors and -or the Stait or ~~sq'

~

ne~oe~

.I.-

~

~

aye cqmeparc.'_Ihe stareiements in this niareofactorer's J atw report with the e~s.nrb-d presso't:!,

-Ian state that pasrts iferij C `idattie ms

~

not in:!%tJ.

r. the ci-?ufirrs'-I ~r m~p-r irtlnbhiOe.been 41asp-01--d beir Ie.and, iba: ts tie hesrt!3C~iytnriwledite 111tfsallief the tstsia esa f-r.Sled this latrastire vcssetien ac.'rdance with,he aprlicd.t~le si'tions, all tie ASRiE

-liani Pros 1e"Pe'Ci. T4, 7escr-sbed vessel wase inspec~ted andtisabjected ;i a he

.'o'tatrce5ai--

-pi IV:. c~

.~c,:

i. it..':-,

ls.ra!ct.cr 1,r fits sýo-.plwvsr italics w.r wd;n!--

~

w tilied~rrplied, concerning the p~4~..'~

'i As-t.-!eils data tsp..zt. Fz1'e~.c.;:t*'er 'he I;;"..

i.r his emV.L ver sbt'ol he :raalt-in an-.i,'

I-

n, v-
..a

,:r:,'-

i rerjya.. ei

~

W,.. K~r. a,;:7 i-:,r co.nnecte~d -with this ir.,i,'ciwsr.

I S4-Ii55-.

P -g-s, t I

-i 5..

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2032 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner First Energy Corp iNAo Shippingoort, PA 15077 (ADDRESS)

Beaver Vallev Power Station Date July 19, 2007 Sheet I

of 1

Unit No.

1 Work Order #200258248/ ECP-07-0049-02

2. Plant (NAME)

Shippinqport, PA 15077

3. Work Performed Ship (ADDRDESS)

Repa&IReplacome Or9gizamfi P.O NoW.

Job No.. etc By BVPS Construction Service Type Code Symbol Stamp N/A (iNME)

Dingoort, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Chemical & Volume Control System-(Class Q2)
5. (a) Applicable Construction Code ANSI B31.1.0 1967 Edition, Summer 1971 Addenda, -

Code Case (b) Applicable Edition of Section XI Utirized for RepairlReplacement Activity 19_89 (c) Applicable Section XI Code Case(s) N-491-2

6. Identification of Components Corrected.

ASME Removed.

Code Nameof Name of Manufactun-National Board Other Year or Stamped Compo Manefarctur Serial No-No.

Identification DeA Installed (Yes or No)

Pipe Support Stone &

N/A N/A ICH-R-6A 1976 Corrected No Webster N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

-N/A N/A

7. Description of Work Addition of (2) 3"x3"x3/8" anqles to restraint CH-R-6A per ECP-07-0049-02.
8. Tests Conducted:

Hydrostatic* [I Pneumatic* El Nominal Operating Pressure [E Exempt 0.

Other E]

Pressure psi Test Temp.

o_ F "Recwd tesa pressure and temperature

FORM I/2-ADM-0801.F02 REV 3 RTL i A4.4 I ý-A FORM NIS-2 (Back) 0 0-.-.. Lc KkI ('rAl rlfl Oý D

^rt, l \\1[;11 I(;il r*t,1 Applicable Manufacture's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp NIA Certificate of Authorization No.

N/A Expiration Date N/A Signed Rob Klindworth w,

rth..*v Owwe or Owrwers De*e Title Date 2S 20 07 CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of J A and employed by,AJA C-T-of 1,44 A 0,4 Q, C 7" have inspected the components described in this Owner's Report during the period e-l_-_/_ __

to

-/f and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the inspector nor his employer ftiakes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind.arisijig-from or connected with this inspection.

L

~Commissions

-iT, z

' OCK?

National Soard. state. Provýnc. aWd Endosrsanents Date 7-/-

, 20 er 7

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2033 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner First Enery Coro (NAME)

Shippingport, PA 15077 Date Sheet October 16. 2007 1

Of 1

2. Plant (ADDRESS)

Beaver Valley Power Station (NAME)

Shi~pinciport. PA 15077 Unit No.

1 Work Order #200223107 / ECP-07-0049-01

3. Work Performed Ship (ADDRESS)

Repair/Replacemert Organization P.O. No.. Job No.. etc.

By BVPS Construction Service Type Code Symbol Stamp N/A (NAME) pingport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Safety Iniection System (Class Q1)
5. (a) Applicable Construction Code ANSI B31.1.0 1967 Edition, Summer 1971 Addenda, --- Code Case (b)

Applicable Edition of Section X1 Utilized for Repair/Replacement Activity 1989 (c) Applicable Section Xl Code Case(s) N-491-2

6. Identification of Components Corrected.

ASME Remooed.

Code Name of Name of Monafacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Idemification BodE Installed (Yes or No)

Pipe Support Stone &

N/A N/A I SI-72-R-309 1976 Corrected No Webster N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

7. Description of Work Remove 3x3x1 /2" angle from support SI-72-R-309 per ECP-07-0049-01.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* E]

Nominal Operating Pressure [I Exempt 0 Other [i]

Pressure psi Test Temp. _

OF

'Record lest pressure and temperature

FORM l/2-ADM-0801.F02 REV 3 RTL 0 A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report Available.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.

Type Code Symbol Stamp N/A Certificate of Authorization No.

A.

Expiration Date N/A Signed Rob Klindworth Date 10/16

, 2007 Owner or Owner's e Toe CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

____9.

and employed by

-J'4d C 7-of W44 T,'O& di /.

C I-have inspected the components descrbed in this Owner's Report during the period

/,-/ ? - 0 to

/10 -

L-A -0 2

.and state that to the best of my knowledge and belief, the Oner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

-Z-, W,

/1,*.-. Ty(

National Board. State. Province. and Endorsements Date 20 d' 7 Date-20

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2034 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner First Enerciv CorD (NAME)

Shippinfwort, PA 15077 Date Sheet September 19. 2007 I

-Of1 (ADRESS)

2. Plant Beaver Vallev Power Station (NAME)

Shippingport, PA 15077 Unit No.

1 Work Order # 200258249 / ECP-07-0049-03

3. Work Performed Ship (ADDRESS)

Repar/Replacement Organization P0. No.. Job No., etc.

By BVPS Construction Service Type Code Symbol Stamp N/A (NAME) pincqport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Chemical & Volume Control System (Class 02)
5. (a) Applicable Construction Code ANSI 131.1.0 1967 Edition, Summer 1971 Addenda, -

Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity.

1989 (c)

Applicable Section Xl Code Case(s),N-491-2

6. Identification of Components Corrected.

ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Iden-lification Built Installed (Yes or No)

Pipe Support Stone &

N/A N/A ICH-R-10 1976 Removed No Webster N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

7. Description of Work Complete removal of support CH-R-10 per ECP-07-0049-03.
8. Tests Conducted:

Hydrostatic* F1 Pneumatic* LI Nominal Operating Pressure LI Exempt [

Other El Pressure psi Test Temp. __OF

  • Record test pressure and temperature

FORM I/2-ADM-08011.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back) 0 01 e

K1 Ide n(r4r-nledý Qi

^~

~

I~I

  • ,.].

l \\5l I I{111*0 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Rob Klindwort Owner or Owner's Designee, Title Date L//Ž.. 20 07 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of _____

and employed by.'<re Cr'-otf

,,-d have inspected the components described in this Owner's Report during!.the period 7-/ 2 to Y-7

< 7 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither theinspector nor his employer sha~l'be liable in any manner for any-personaIinjury:orproperty damage'or a lossof any kind arising from or connected with thisý,inspection.".

Commissions 2

'/'

1 A -? -9 IlnspectoýSignature National 16ard, State, Province, and Endorsements Date

,20.

, 20 C -?

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2035 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner First Energy Corp (NAME)

Shippinqpiort, PA 15077 (ADDRESS)

Beaver Valley Power Station Date June 28, 2007 Sheet 1

of 1

Unit No.

1 Work Order #200258250 / ECP-07-0049-04

2. Plant (NAME)

Shinninnnort PA 15077

3. Work Performed Ship (ADDRESS)

Repair/Replacement Ogantization P.O. No., Job No., etc-By BVPS Construction Service Type Code Symbol Stamp N/A (NAME) pinwport, PA 15077 Authorization No.

N/A.

(ADDRESS)

Expiration Date N/A

4. Identification of System Safety Injection System (Class 02)
5. (a) Applicable Construction Code ANSI B31.1.0 1967 Edition, Summer 1971 Addenda, --- Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity.

1989 (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected.

ASME Removed.

Code Nme of Name of Maufacturer National Board Other Year o0 Stanaped Component Manufacturer Serial No.

No.

Ideotification Built Installed (Yes or No)

Pipe Support Stone &

N/A N/A ISI-R-19 1976 Removed No Webster

7. Description of Work Complete removal of support SI-R-19 Der ECP-07-0049-04.
8. Tests Conducted:

Hydrostatic* [I Pneumatic* El Nominal Operating Pressure [L Exempt 0 Other E]

Pressure psi Test Temp.

° F

  • Record test pressure and temperature

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.41!4-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available.

Applicate Mwasnuackuers Data Repmpt to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Rob Klindworth Date 2007 Owner or Owner's Designee, Tittle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of -

and employed by

,/

7/',

C7of

/-/*q ZT/X2.,C d,

C have inspected the components described in this Owner's Report during the period to

,2 -J

- 67

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures' des-cribed in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind'arising from or connected with this inspection.

~~~Commissions

'3

/

2,

signature National Board. State. Province. and Erdosernents Date

.20

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No-2037 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)
2. Plant Beaver Valley Power Station (BVPS)

Date Sheet 10/19/2007 1

of 3

Unit No.

1 (NAME)

Shippingport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Construction Service (NAME)

Shippincqport, PA 15077 (ADDRESS)

Work Order #200229928 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date

4. Identification of System Safety Iniection (Q1)
5. (a) Applicable Construction Code ANSI B31.1 1967.Edition, S'71 Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity_

1989 (c)

Applicable Section XI Code Case(s): N-416-2

6. Identification of Components Corrected, ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No-Noý Identification Built Installed (Yes or No)

Globe Valve Edwards Valves 47 N/A I SI-97 1997 Removed No Throttle Valve Masoneilan/Dresser 448414-1-2 N/A 1SI-97 2007 Installed Yes Gate Valve Velan 061001-2 N/A ISI-483 2007 Installed Yes Pipe Energy &

N/A N/A Ht. #037046 2006 Installed No Process

7. Description of Work Replaced throttle valve and installed a new isolation valve and pipe.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* []

Nominal Operating Pressure M Exempt.-]

Other El Pressure psi Test Temp. _°OF

  • Record test pressure and temperature

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Code Data Report attached. Previous NIS-2 Data Report No. 954. Replacement valve Applicable Manufacturer's Data Reports to be attached 1SI-97 was manufactured to ASME Sect. III 2001E-2003A. Class 2. New valve 1SI-483 was Manufactured to ASME Sect. III 1989E. Class 1. Both valvesare installed into an ANSI B31.1 system.

CERTIFICATE OF COMPLIANCE I certify that the statements made in'the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Senior Specialist Date October24

, 20 07 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

-' (

to Z

(3 9"- 0 '

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in'this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

-,I-t/,

National Board, State. Province, and Endorsements

Insp,

's Signature Date

/0

-(-

, 20 0 ?

FORM NPV-1. CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code,Section III, Division 1 Page 1 of 2

  • CORRECTED 11/1/07
1. Manufactured and certified by uresser Inc. Mat
2.

Manufactured for First Energy P.0

3. Location of inslallalion First Energy Ger
4.

Model No.. Series No., or Type 20-18439

5. ASME Code,Section III. Division 1:

2001 (edition)

6.

Pump or valve VALVE

7.

Material:

a) Valve Body SA 351 GR CF8M Bonnet b) Pump Casling Cover soneilan Operations 85 B~owell St. AvWon, MA 02-322 (namre and address ot N Certificate Holder)

Box 6100 Johnstown. PA 15907-6100 Inarne and address of Purchaser) teration Dist. Center Beaver Valley Rte 168 Shippingport PA 15077 (name and address)

Drawing 448414-1 Rev.

  • F 2003 2

CRN N/A N/A (Code Case no.)

2 INCH iin1) faddenda dare)

Nominal inlet size SA 182 GR F316.

(class)

INCH Outlet size (in.)

Disc SA 479 TYPE 410 Bolting SA 453 GR 660 Bolting (a)

(b)

(c)

(d)

. (e)

Cert.

Nat')

Body/Casting Bonnet/Cover Disc Holder's Board Serial Serial Serial Serial No.

No.

No.

No.

No.

N 448414-1-2 N/A 21715-3 242605 T1445-DEO 4

f 4

+/-

I 4

1

+

1 4

I 4

1 4

4 1-4

+

1 4

I

+

i i

i

  • Supplemental information in form of lists, sketches, or drawings may be used provided (1) size is 8,/,, x 11, (2) information in items 1 through 4 on this Data Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/88)

This form (E00037) may be obtained from the Order Dept., ASME, 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300.

FORM NPV-1 (Back - Pg. 2 of 2)

Cetiticate Iolder's Seral No.

N 448414-1-2

8.

Design Conditions 2485 psi 650 ipress*rle )

Feempret aurni "F or valvp pressure class

~1)

9.

Cold working pressure 3782.5 psi at 1O0"F

10. Hydroslatic test 5675 psi Disk differenlial test pressure

'SEE REMARKS psi

11.
  • Rermnarks NC-3531.4 Exemptions to the Valve Closure Test (b)For valves designed for nonisolation service, the primary function of which is to modulate flow, and Which by their design are prevented from providing full closure, the valve closure test defined in NC-3531.2 is not required. Do to size limitation of name plate this requirement could not be Identified on the name plate itself.

CERTIFICATION OF DESIGN Design Specification certified by FRANCIS W. GARDNER P.E. State PA Reg. no, 036614-E Design Report certified by L.C. LUCKHARDT P.E. State ONTARIO Reg. no.

27575505 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division:

N Certificate of Authorization No.

N-1836 DRESSER INC. MASONEILAN OPERATIONS,. 85 BODWELL Date 11/1/07 Name ST. AVON, MA 02322 Expires NOVEMBER 19, 2007 Signed s -.

f-,,2 (N Cerbticate Holder)

(

6/ (authorized representative)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of MA and employed by HSB CT of HARTFORD, C have inspected the pump, or valve, described in this Data Report on

/7

,i-7

/0-;?

and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code,Section III. Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property f

oi loss o ny kind arising from or connected with this inspection.

Dat

!~L*7Signe_,

7"

1. -

commissions

+7

/V f (Authdtized Nuclear Inspector)

INatl Bd. (ind. endorsements) and state or proc. and no.

(1) For manually operated valves only.

2 of 32)

DATA PACKAGE NO.

061001 FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES

  • As Required'by the Provisions of the ASME Code,Section III, Division 1 Pg. 1 of 2
1. Manufactured and
2. Manufactured for certified by VELAN INC. 2125 WARD AVE,MONTREAL.QUEBEC CANADA H4MIT6 (name and address ofN Ceriated Holder)

FRAMATOME-ANP.

331S-A OLD FOREST RD.,

L.NCHBURG, VA.,.USA,.24501 (name and address of purhaser) 3i Location of installation NOT AVAILABLE (name and address)

4.

Model No.,

Series No.,i or Type:

GATE Drawing P1-76800-N22 Rev H

CRN N/A

5.

ASME Code,Section III, Division 1:

1989 NONE I

N/A (add )

(addend date)

(class)

(Cod Case no.)

6.

Pump'or valve VALVE Nominal inlet size 21 Outlet size 2-( )

(in0)

7. Material: Body SA-182,F316 Bonnet SA-182,F316 Disk SA-351, Bolting SA564.,630H1100 CF8M SA-194,GR8M (a)-

Cert.

Holder ' s Serial No.

(b)

Nat'1 Board No.

(a)

Body Serial No.

(d)

Bonnet Serial

.No.

(e)

Disk Serial No.

061001-1 N/A H/C:

CEZH H/C:

KIF H/C:

86K

.061001-2 N/A H/C:

CE H/C:

KIF H/C:

86K 061001-3 N/A H/C:

CER H/C: KIF H/C:

86K.

.061001-4 N/A H/C:

CEH H/C:

KIF H/C:

86K 061001-5 N/A H/C:

CEH H/C:

KIF H/C:

86K

.061001-6 N/A H/C:

CEH H/C:

KIF

° H/C:

86K Supple*cnt informaton in form of lsts, skcwhm ordrawing may be used povided(1) size is 81/2 x 1I, (2) informdaon in items I though 4 on tris Dat Report is included on eac'hsheet, (3) each shee 's nmbemd and the nmber of sheets is reco.ded at tde top of this form.

(12/88)" "

5

  • T form (100037) may b.°btamed from the Ordel Dept., ASME., 22 LAW DRIVE, Box 2300, Fairfield, NJ 07007-2300.

JOPSUPJ REGJ PAGE -

OF

-.1 ý., L6.

?age 13 of 32)

FORM NPV-1 (Back -

Pg.

2 of 2

Certificate Holder's Serial No.

061001

8. Design conditions 4055 psi 100 (pressure)

(temperature)

9.

Cold. working pressure

4055, psi at 1000F

'F or valve pressure class

.1690 (1)

10. Hydrostatic test 6100 psi.

Disk differential test pressure 4475 psi 11; Remarks:

MATERIALS MEET ASME SECTION II EDITION: 1989* ADDENDA:

NONE CERTIFICATE OF DESIGN Design Specification certified by M. LAVIGNE P.E. State QUE Reg. no.

40052 Design report certified. by S.

ISBITSKY P.E. State.

QUE Reg. 'no..

22115 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-2797-1 Expires APR 20,2007 Date JAN 1`7 2W6 Name VELAN INC.

Signed. CO (B

(N C-fificate Hokkar)

(auffhorized mrqusintative)

CERTIFICATE OF INSPECTION I,

the undersigned, holding a valid commission issued by the National Board of Boiler and pressure vessel Inspectors and the State or Province of QUEBEC and employed by REGIE DU BATIMENT.

lOf QUEBEC9 have inspected the pump, or valve, described in

  • this;Data Report on r

2-5, and state that to the, best of my knowledge and belief; the Certificate Holerd*has-constructed this pump, or valve, in accordance with-,the ASME Code, Section. III.

Division-1;.

By-- signing-this, certificate neither the inspector nor his: employer makes any warranty,

.expressed,. or implied,. concerning: the' component described-in this Data Report. Furthermore, neither"the..inspector nor his emdployei shall be liable in any.maner for any personal. injury Or propertydamage or a los ay.. nd arising from. or connected with Date J"a.:

(b signed

'.1s" VJ.-.FA

.A

-(Authoried

)Nf

~ M9

ýad uto rv n no.)

(1) For manually operated valves. only.

OP SRUp.

H PAGEAI', OFaQ I

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2038 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron, OH 44308 Date Sheet 10/19/2007 1

of 3

(ADDRESS)

Beaver Vallev Power Station (RVPSI'

2. Plant Unit No.

1 (NAME)

Shippincqport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Construction Service (NAME)

ShiDDinoDort. PA 15077 Work Order #200222640 Repair/Replacement Organization P.0. No.. Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date (ADDRESS)

4. Identification of System Safety Injection (Q1)

.5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, N/A Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 1989 (c)

Applicable Section XI Code Case(s): N-416-2

6. Identification of Components Corrected.

ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Globe Valve Rockwell Int'l.

N/A N/A ISI-98 1976 Removed No Throttle Valve Masoneilan/Dresser 448414-1-4 N/A ISI-98 2007 Installed Yes Gate Valve Velan 061001-1 N/A ISI-484 2007 Installed Yes Pipe Energy &

N/A N/A Ht. #037046 2006 Installed No Process

7. Description of Work Replaced throttle valve and installed a new isolation valve and pipe.
8. Tests Conducted:

Hydrostatic* [i Pneumatic* []

Nominal Operating Pressure N Exempt El Other EL Pressure psi Test Temp.

°OF

  • Record test pressure and temperature

FORM I/2-ADM-080LF02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Code Data Report attached. Replacement valve 1SI-98 was manufactured to ASME Applicable Manufacturer's Data Reports to be attached Sect_ III 2001 E-2003A Class 2_ New valve 1SI-484 was manuffactured tn ASMF Senr:t IlI 1989F Class 1. Both valves are installed into an ANSI B31.1 system.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorizatdon Signed N/A Expiration Date N/A Senior Specialist Date October 25

, 20 07

.Owner or-Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vesselinspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period G-to

/ '

'* 9,and state that to the best of my knowledge and belief, the Owner hasperformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer, makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectionm InspectorSignature Commissions T-, ^/,

/

q4 )--2? *'q National Bi5ard, State, Promce, and Endorsements Date

/0

'-3/1-

, 20 ()7

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code,Section III, Division 1 Page 1 of 2

  • CORRECTED 11/1/07
1. Manufactured and cerfified by Dresser Inc. Masoneilan Operations 85 Bodwell St. Avon, MA 02322
2.

Manufactured for

3.

Location of installation (name and address of N Certihicate Holder)

First Energy P.O. Box 6100 Johnstown, PA 15907-6100 (name and address of Purchaser)

First Energy Generation Dist. Center. Beaver Valley Rte 168 Shippingport PA 15077 (name and address)

4.

Model No., SeriesNo. orType 20-18439

5.

ASME Code, Section 1I1, Division 1:

2001 Drawing 448414-4 2003 Rev.

  • F 2

CRN N/A N/A ledibor)

6.

Purnporvalve VALVE (addenda date)

(class) 2 INCH Outlet size (in.)

(Code Case nr.)

2 INCH (in.)

Nominal inlet size

7.

Material:

a) Valve Body b) Pump Casting SA 351 GR CF8M Bonnet Cover SA 182 GR F316 Disc SA 479 TYPE 410 Bolting Bolting SA 453 GR 660 (a)

(b)

(c)

Id)

(e)

Cert.

Nafl Body/Casting Bonnet/Cover Disc Holder's Board Serial Serial Serial Serial No.

No.

No.

No.

No.

N 448414-1-4 N/A 21666-2 242605 T1445-DEO

  • Supplemental information in form of lists, sketches, or drawings may be used provided (1) size is 81/1 x 11, (2) information in items 1 through 4 on this Data Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/88)

This form (E00037) may be obtained from the Order Dept., ASME, 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300.

FORM NPV-1 (Back - Pg. 2 of 2)

Cetificate Hohle~s Sernil No.

N 448414-1-4 8,

D[,r!;ign Conditions 2485 psi 650 TF or valve piusour class (P'Vssu"rf' (temrperalute)

(1)

9.

Cold working pressure 3782.5 psi at 100-F

10.

Hydrostatic test 5675 psi Disk difterenlial lest pressure

  • SEE REMARKS psi
11.
  • Remarks NC-3531.4 Exemptions to the Valve Closure Test (b)For valves designed for nonisolation service, the primary function of which is to modulate flow, and Which by their design are prevented from providing full closure, the valve closure test defined in NC-3531.2 is not required. Do to size limitation of name plate this requirement could not be Identified on the name plate itself.

CERTIFICATION OF DESIGN Design Specification certified by FRANCIS W. GARDNER P.E. State PA Reg. no.

036614-E Design Report certified by L.C. LUCKHARDT P.E. State ONTARIO Reg. no.

27575505 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division.

N Certificate of Authorization No.

N-1836 Expires NOVEMBER 19, 2007 DRESSER INC. MASONEILAN OPERATIONS, 85 BODWELL Date 11/1/07 Name ST. AVON, MA 02322 l)AA-J

~-

Signed (N Certificate Holder)

/

6 /authonized represenlative)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of MA and employed by HSB CT of HARTFORD, CT have inspected the pump, or valve, described in this Data Report on 1/ 7_'&;7 and state that to the best of my knowledge and belief, the Certificate Holder has onistrutted this pump, or valve, in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property "d ge or a loss of ny kind arising from or connected with this inspection.

Date

/44LL Signed-.

/

Commissions.,/1W,/1 j/V.2 (Authorized Nuclear Inspector)

[Nail Bd. (ind. endorsements) and state or prov. and no.]

(1) For manually operated valves only.

(Page 12 of 32)

DATA PACKAGE NO.

061001 FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES

1 of 2

1. Manufactured and
2. Manufactured for
3. Location of insta certified by VELAN INC.

2125 WARD AVE,MONTREAL.QUEBEC CANADA H4MIT6

([ame and addr~ss of N Cnlificate Holder)

FRAMATOME ANP.

3315-A OLD FOREST RD.,

LYNCHBURG, VA., USA, 24501 (name and address of purTAsAL)

Ilation NOT AVAILABLE A T

( n e a n d a d d r e s s )

.4. Model No., Series No.,j or Type:

GATE___

Drawing P1-76800-N22 Rev H CRN N/A

5.

ASME Code,Section III, Division 1:

1989 NONE 1

N/A (edition)

(adrda date)

(Class)

(Code Casie no.)

6.

Pump 'or valve VALVE Nominal inlet size 2-Outlet size 2-C-)

7. Material: Body SA-182,F316 Bonnet SA-182,F316 Disk SA-3S1, CF8M

. (a)

Cert.

Holder's Serial No.

(b)

Nat'l Board No.

Bolting SA564,630H1100 SA-194,GR8M Disk Serial No.

(a)

Body Serial No.

(d).

Bonnet Serial No.

061001-1 061001-2 061001-3 061001-4 061001-5 061001-6 N/A N/A N*/A N/A N/A N/A.

H/C:

CEH H/C:

CEH H/C:

CEH H/C:

CEH H/C:

CEH H/C:

CEH H/C:

KIF H/C:

KIF H/C:

KIF H/C:-

KIF H/C:

KIF H/C:

KIF H/C:

86K H/C:

86K H/C:

86K H/C:

86K H/C:

86K H C: "6K Supplemahtal information in fobrm of lists, skeches, o sdrawinPs issed provide d (1) size is 8 1/2 x 11,(2) infonnation in items I tmugh 4on this Data Report is included on each..she -et. (3) each sheet is* numbered and the number of sheets is recorded at the top of this form (12/88)"

This form (E00037) maybe obtained fmm thecOrde-Dept., ASME, 22 LAW DRIVE, Box 2300. Fairfick NJ 07007-2300.

REOPSU IITAGE.

OFA

(Page 13 of 32)

- ý C.-

FORM NPV-1 (Back -

Pg.

2 Of 2

Certificate Holder's Serial No.

061001

8. Design conditions 4055 psi 100 (pressure)

(temperature)

9. Cold. working pressure 4055-psi at 100*F
  • F or valve pressure class.

-1690 (1)

10. Hydrostatic test 6100 psi.

Disk differential test pressure 4475 psi ll; Remarks:

MATERIALS MEET ASME-SECTION II EDITION: 1989 ADDENDA:

NONE CERTIFICATE OF DESIGN Design Specification certified by M. LAVIGNE P.E. State QUE Reg.

no.

40052 Design report certified-by

s.

ISBITSKY P.E. State.

QUE Reg. 'no.

22115 CERTIFICATE :O COMPLIANC We certify that the statements, made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME-Code,Section III, Division 1.

N Certificate of Authorization No.

N-2797-1 Expires APR 20,2007 Date NAN a"I 26

  • Nme VELAN INC..

Signed CAW, (N Certificate HoWier)

(auffiorized r-eprsetafive)

CERTIFICATE OF INSPECTION I,

the undersigned, holding a valid commission issued by the National Board of Boiler and

.pressure Vessel Inspectors and the State or Province of QUEBEC and employed by REGIE DU BATIMENT of QUEBEC4 have inspected the pump, or valve, described in this Data Report on*

, and state that tO the best of my knowledge and

  • belief, the Certificate:H0dlr has constructed this pump, or valve, in accordance with the AsmE Code,- Section. III: Division1.-

I By signing-this certificate, neither the-inspector nor hisemployer makes: any warranty,

.expressed or implied, concekining'the component described in this Data Report. Furthermore,

'eiher'the inspector nor his employe. shall be liable in any manner for any personal injury or property'damage or a los qfa y

y.

nd arising from. or connected with this__insperio i

-J.-P.5AC~14qtL F

I CCI o

Date 2 Z signed Commissions QUEBE ni ndtep (Aut- &r i ze.d...*I c

B&M!W

ýts) a t

n no.)I (1) For manually operated valves only.

oP S.P REG' PAGE-~

OF~.B

FORM l/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2039 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron. OH 44308 Date 10/19/2007 Sheet 1

of 3

Unit No.

1

2. Plant (ADDRESS)

Beaver Valley Power Station (BVPS)

(NAME)

ShiDoinaoort. PA 15077 Work Order #200229929 (ADDRESS)

3. Work Performed By BVPS Construction Service (NAME)

Shippinqport, PA 15077 (ADDRESS)

Repair/Replacement Organization P.O. No. Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date

4. Identification of System Safety Iniection (Q1)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition,.

S71 Addenda, N/A Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 (c)

Applicable Section Xl Code Case(s): N-416-2

6. Identification of Components Corrected.

ASME

Removed, Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Globe Valve Rockwell Int'.l.

N/A N/A 1ISI-99 1976 Removed No Throttle Valve Masoneilan/Dresser 448414-1-i N/A ISI-99 2007 Installed Yes Gate Valve Veian 061001-6 N/A ISI-485 2007 Installed Yes Pipe Energy &

N/A N/A Ht. #037046 2006 Installed No Process

7. Description of Work Replaced throttle valve and installed a new isolation valve and pipe.
8. Tests Conducted:

Hydrostatic* El Pneumatic* El Nominal Operating Pressure M Exempt El Other El Pressure psi Test Temp. _°OF

  • Record test pressure and temperature

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Code Data. Report attached. Replacement valve 1SI-99 was manufactured to ASME Applicable Manufacturer's Data Reports to be attached Sect. III 2001 E-2003A. Class 2. New valve 1 SI-485 was manufactured to ASME Sect. III 1989E.

Class 1. Both valves are installed into an ANSI B31.1 system.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

Signed N/A Expiration Date N/A Senior Specialist Date October25

, 20 07 L.

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the.State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

'7-/'9 0 O to

/ 0 -

-0 '7 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XA.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Z Commissions Inspect Signature National Board, State, Province, and Endorsements Date

/

-/

20 0

I

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code,Section III, Division 1 Page 1 of 2

  • CORRECTED 11/1/07
1. Manufactured and certified by Dresser Inc. Masoneilan Operations 85 Bodwell St. Avon, MA 02322 (namre and address of N Certificate Holder)

First Energy P.O. Box 6100 Johnstown, PA 15907-6100

2. Manufactured for
3. Location of installation (name and address of Purchaser)

First Energy Generation Dist. Center Beaver Valley Rte 168 ShippinqDort PA 15077 (name and address)

4.

Model No., Series No., or Type 20-18439

5.

ASME Code. Section Ill. Division 1:

2001 Drawing 448414-1 2003 Rev.

  • F 2

CRN N/A N/A

6. Pump or *alve VALVE (edition)

(addenda date)

(class

6.

Purrporvatve VALVE Nominal inlet size 2 INCH fin.)

(Code Case no.)

Outlet size 2 INCH (in.)

7.

Material:

a) Valve b) Pump Body SA 351 GR CF8M Bonnet Casting Cover SA 182 GR F316 Disc SA 479 TYPE 410 Bolting Bolting SA 453 GR 660 (a)

(b)

(c)

(d)

(e)

Cerl.

Nat'l Body/Casting Bonnet/Cover Disc Holder's Board Serial Serial Serial Serial No.

No.

No.

No.

No.

N.448414-1-1 N/A 21666-1 242605 T1445-DEO I

I.

[

I

  • Supplemental information in form of lists, sketches, or drawings may be used provided (1) size is 8'/, x 11, (2) information in items 1 through 4 on this Data Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/88)

This form (E00037) may be obtained from the Order Dept., ASME, 22 Law Drive, Box 2300, Fairfield, NJ 07007-2300.

FORM NPV-1 (Back - Pg. 2 of 2)

,olifical,* Holdeis Serial No.

N 448414-1-1

8.

Design Coditions 2485 psi 650 "F or valve pressute class (1)

(ples.sule)

(leneoeralule)

9.

C0old wokirr.q pressure 3782.5 psi at 100°F

10. Hyhoslatic lesl 5675 psi Disk dillerential lest pressure

'SEE REMARKS psi 11 Rernarks NC-3531.4 Exemptions to the Valve Closure Test (b)For valves designed for nonisolation service, the primary function of which is to modulate flow, and Which by their design are prevented from providing full closure, the valve closure test defined in NC-3531.2 is not required. Do to size limitation of name plate this requirement could not be Identified on the name plate itself.

CERTIFICATION OF DESIGN Design Specification certified by FRANCIS W. GARDNER P.E. State PA Reg. no.

036614-E Design Report certified by L.C. LUCKHARDT P.E. State ONTARIO Reg. no.

27575505 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division.

N Certificate of Authorization No.

N-1836 Expires NOVEMBER 19, 2007

,DRESSER INC. MASONEILAN 7-OPERATIONS, 85 BODWELL Date 11/1/07 Name ST. AVON, MA 02322 Signed (N Certificate Holder)

(/4rutlnsnzed representative)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of MA and employed by HSB CT of HARTFORD, CT have inspected the pump, or valve, described in this Data Report on and state that to the best of my knowledge and belief, the Certificate Holder has construc(ed this pump, or valve, in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Beport. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or prope age or a loss f any kind arising from or connected with this inspection.

Dale Signed

(__thorCommissions B/, (l ea (AMlhoiized Nuclear Inspector)

INart' 8d. (Inc. endorsements) and slate or prov. andI no.]

(1) For manually operated valves only.

  • (IagZ 1C2 - of 32)

DATA PACKAGE NO.

061001 FORM NPV-I CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES

  • As Required'by the Provisions of the ASME Code,Section III, Division 1 Pg. I of 2
1. Manufactured and certified by VELAN INC. 2125 WARD AVE,MONTREAL.QUEBEC CANADA H4MIT6 (name and address of N C*-ificate Holder)
2. Manufactured for FRAMATOME ANP.

3315-A OLD FOREST RD.,

LYNCHBURG, VA., USA, 24501

(

amead address of purhase)'

3. Location of installation NOT AVAILABLE (meand address)
4.

Model No.,

Series No. i or Type:

GATE Drawing PI-76800-N22 Rev H

CRN N/A

5.

ASME Code,Section III, Division 1:

1989 NONE I

N/A (edition)

(addena date)

(cas)

(Code Case no.)

6.

Pump or valve VALVE Nominal inlet size 2-Outlet size 2_

7. Material: Body SA-182,F316 Bonnet SA-182,F316 Disk SA-351, CFSM Bolting SA564,630H1100 SA-194, GR8M (a)

Cart.

Holder's Serial No.

(b)

Nat'l Board NO.

(a)

Body Serial No.

(d)

Bonnet Serial No.

(e)

Disk Serial No.

061001-1 061001-2 061001-3

.061001-4 06M001-5 061001-6 N/A N/A N/A N/A N/A N/A H/C:

CEH H/C:

CEH HI/C:

tCEH

'H/C:

CEN li/C:

CER H/C:

CEH H/C:

KIF H/C:

KIF H/C:

KIF H/C:- KIF H/C:

KIF H/C:

KIF H/C:

86K H/C:

86K H/C:

86K-.

H/C:

86K H/C:

86K H/C.:

86K 7-Supplemnotal information in foim of lists, sktches, or drawings may be used prOvided (1) size is 8 1/2 xl I, (2) information in items I through 4 on this Data Report is included onach shckht (3) each sh,t is numbmed and the number ofsheets.is r*corded at the top of this form.

(12/88)*

Thiform (E00037) maybe obtaned from the Ordr Dept., AASME__,

22 LAW DR1VEM Box 2300, Fairfield, NJ 07007-2300.

I REOPSU If.PAGE.~

OF ~

?age 13 of 32)

FORM NPV-1 (Back - Pg.

2 of 2

Certificate Holder's Serial No.

061001

8. Design conditions 4055 psi 100 (pressure)

(temperature)

9. Cold. working pressure 4055 psi at 1000,
  • F or valve pressure class

-1690 (1)

10. Hydrostatic -test 6100 psi.

Disk differential test pressure 4475 psi

11. Remarks:

PMATERIALS MEET ASME SECTION II

. EDITION: 1989 ADDENDA:

NONE CERTIFICATE OF DESIGN Design Specification certified by M. LAVIGNE P.R. State QUE Reg. no.

40052 Design report certified by S.

ISBITSKY P.E. State.

QUE Reg. no.

22115 CERTIFICATE:OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-2797-1 Expires APR 20,2007 Date JAN 1"7 L6 Signed __LC03k,~~IO1 Name VELAN INC..

J I

i (N Caftfca HoMer)

(auihodzed repiescidative)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and pressure Vessel Inspectors and the State or Province of QUEBEC and employed by REGIE DU BATIMENT-of QUEBEC have inspected the pump, or valve, described in this'Data Report on 12>;*X -5*

and state that to the. best-of my knowledge. and belief, the Certificate.-Holder has. constructed this pump, or valve, in accordance-with the AsmE Code,' Section. IIIW Divislion 1.'-.

By. signing-this certificate, neither the. inspector nor his:employer makes*: any warranty,

.expresse.d or.implied,. concerning the component described in thi.s Data Report. 'Furthermore, neither" the.inspector nor his employe shall be liable in any manner for-any personal-injury or property'damage or a los f

y.

nd arising from. or connected with hi*nse*ris r*$3 J.-P.FACHIE I I Date

ýAv '2 r

ind.commissin QUB no.)

(1) For manually operated valves only.

jOP S-UP REGs-I HPAGE-'A

_Vo~QFAL

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2043 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner
2. Plant First Energy Corp.

(NAME)

Shinninnnnrt PA 1IrF,)77 Date 5/23/07 Sheet 1

of 1

(ADDRESS)

Beaver Vallev Power Station Unit No.

1 (NAME)

Shiooinanort. PA. 15077 ECP-07-0059-01 (200223109)

3. Work Performed Shio (ADDRESS)

Repair/Replacenient Organization P.O. No.. Job No.. etc.

By BVPS Construction Type Code Symbol Stamp N/A (NMAE) pinfgport, PA. 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Recirculating Spray (Code Class 2)
5. (a) Applicable Construction Code ANSI B31.1.0 1967 Edition, Summer 1971 Addenda,

-- Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 (c) Applicable Section Xl Code Case(s): N/A

6. Identification of Components Corrected.

ASME Remoted.

Code Nare of Name of Manufacturer National Board, Other Year or Stamprd Componntr Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Pipe Support Stone & Webster N/A N/A I RS-A-24 1976 Corrected No

7. Description of Work Removal of diagonal braces and base plates to provide clearance for Expanded sump strainer
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* L Nominal Operating Pressure EL Exempt [

Other El Pressure psi Test Temp.

° F

  • Record test pressure and temperature

FORM l/2-ADM-0801.F02 REV 3 RTL # A4.41, A-A FORM NIS-2 (Back)

9. Remarks No Code data report available Applicabe ufactwer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Willis R. Garman - Enineer a

Date 9/26

.20 07 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. Ct.

have inspected the components described in this Owner's Reportdurngtheperiod to

/0 X -0 2 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xl.

By signing thisi certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

J-Q'ý J '4'-d -

Commissions 2?-,

,.J, l/e.

,,A? P>C Inspector's 50nature National Board. State. Province. and Endorsernents Date

, 20 (19 Date

.20 o2

FORM i/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2044 FORM NIS-2 OWNER'S REPORT FOR REPAIRSlREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner
2. Plant First Enerqy Corp.

(NAoE)

Shippinciport. PA. 15077 Date 5/23/07 Sheet 1

of 1

(ADDRESS)

Beaver Vaflew Power Station Unit No.

1 Shippingport. PA_ 15077 ECP-07-0059-02 (200252864)

3. Work Performed Ship (NAME)

Shippinqport, PA. 15077 (ADDRESS)

Repair/Retlacement Orgardzation P.0- No.. Job No., etc.

By BVPS Construction Type Code Symbol Stamp N/A (N"AE) pincqport, PA. 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Residual Heat Removal (Code Class 2)
5. (a) Applicable Construction Code ANSI B31.1.0 1967 Edition, Summer 1971 Addenda, Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity.

1989 (c) Applicable Section XI Code Case(s): N-491-2

6. Identification of Components Corrected.

ASME Remo-ed.

Code Nare of Name of Manufacturer National Board td.

Year or Stamped Componert Manufacturer Serial No.

No.

Identification Boik Installed (Yes or No)

Pipe Support Stone & Webster N/A N/A IRH-A-I 1976 Corrected No

7. Description of Work Removal of diagqonal brace and base plate to provide clearance for Expanded sump strainer
8. Tests Conducted:

Hydrostatic* El Pneumatic* ]

Nominal Operating Pressure El Exempt Z Other E]

Pressure psi Test Temp.

O F

-Record test pressure and temperature

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code data report available Apicable Manifaurer's Data Rewots to be atlahed CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp NIA Certificate of Authorization No.

N/A Expiration Date WA Signed Willis R. Garman - Engineer Owner or Owner's Designee. Title Date 9/26 20 07 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Presstme Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, Ct.

have inspected the components described in this Owner's Report during the period

'/'

to

/.

L. X - 0 2, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspect s signature Commissions f W/

A4 d-I z (/

National Board. State, ProAnoe. and Endorsements Date 20 A Dt I

FORM.1/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2051 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C.

(NAME) 76 South Main Street - Akron, OH 44308 Date Sheet Unit No.

10/8/2007 (ADDRESS)

Beaver Valley Power Station 1

of 1

1

2. Plant (NAME)

Shippincqport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Maintenance (NAME)

Shippincqport, PA 15077 (ADDRESS)

Work Order # 200262528 Repair/Replacement Organization P.O. No.. Job No., etc.

Type Code Symbol Stamp Not Applicable Authorization No.

N/A Expiration Date N/A

4. Identification of System Diesel Generator Fuel Oil (Q3)
5. (a) Applicable Construction Code

-ANSI B16.5 1968 Edition, N/A Addenda, N/A Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 1989 (c) Applicable Section X1 Code Case(s) N/_A

6. Identification of Components Corrected.

ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Composent Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Check Valve Crane N/A N/A 1FO-36 1976 Corrected No

7. Description of Work Replaced body to bonnet capscrews
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* LI Nominal Operating Pressure LI Exempt Z Other El Pressure psi Test Temp.

o_ F Record test pressure and temperature

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code.Data Report available. Replaced 3/4/4" Capscrews: PO. 45237967 / Ht. #OV93.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Senior Specialist Date November 13 20 07 Owneror Oner' DesineeTitl CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford CT have inspected the components described in this Owner's Report during the period

'('

9"

  • to

/I* --,O and.state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed. or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in: any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspecrs Signature Commissions

,J

/4 d, 2 National Board, State, Province, and Endorsements Date

/

20/0 20 Om2.

FORM.I/2-ADM-0801 F02 REV 3 RTL # A4.414-A Form No.

2055 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY

" As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C.

(NAME) 76 South Main Street - Akron, OH 44308 Date Sheet Unit No.

10/30/2007 1

of 1

1 (ADDRESS)

2. Plant Beaver Vallev Power Station (NAME)

Shippinqport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Construction (NAME)

Shippingport, PA 15077 (ADDRESS)

Work Order # 200228102 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp Not Applicable Authorization No.

N/A Expiration Date N/A

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S71 Addenda, N/A Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity-1989 (c)

Applicable Section XI Code Case(s): N-416-2

6. Identification of Components Corrected.

ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Pipe Stone &

N/A N/A 24"-WR 1976 Corrected No Webster 151-Q3 Pipe Energy &

N/A N/A HT# RY5529 2003 Installed No Process Corp

7. Description of Work Replaced section of pipe.
8. Tests Conducted:

Hydrostatic* Li Pneumatic* E]

Nominal Operating Pressure N Exempt El Other FI Pressure psi Test Temp.

O F

'Record test pressure and temperature

FORM 1/2-ADM-080l.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks NoCode Data Renort available.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of A orizationNe-N/A Expiration Date N/A Signed Senior Specialist Date October 31

, 20 07 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National-Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

- [

to

/0 --.ý-

0?and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector norhis employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions z t,$

//

?

National Board, State, Province. and Endorsements inspector's&

ature Date

//-/V-

,20 0"7

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2056 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C.

(NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)

2. Plant-Beaver Valley Power Station (NAME)

Shippinqport, PA 15077 (ADDRESS)

3. Work Performed By.

BVPS Valve Team (NAME)

Shiooinaoort. PA 15077 Date Sheet 10/16/2007 1

of 1

Unit No.

1 Work Order #200031462 Repair/Replacement Organization P.O. No., Job No.. etc.

Type Code Symbol Stamp Not Applicable Authorization No.

N/A Expiration Date N/A (ADDRESS)

4. Identification of System Quench Spray (Q2)
5. (a) Applicable Construction Code ANSI 816.5 1968 Edition, N/A Addenda, N/A Code'Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 1989 (c) Applicable Section Xl Code Case(s) N/IA

6. Identification of Components Corrected.

ASME Removed.

Code Name of Name of Manufacturer National Other Year or Stamped Component Manufacturer Serial No.

Board Identification Built Installed (Yes or No)

No.

Gate Valve Pacific Valve 158076 N/A MOV-IQS-100A 1976 Corrected No "7 r~.

$1 J~~l-I.

n I--,

L.

T

i.

D.escriptuio o1 vvorrt Replacedu bouv to bornnet studs a~nd nuts.

8. Tests Conducted:

Hydrostatic* E]

Pneumatic* E]

Nominal Operating Pressure El Exempt 0 Other El Pressure psi Test Temp. __OF

  • Record test pressure and temperature

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Replaced body/bonnet 3/4" Studs: P.O. 45189502 / Ht. #

Applicable Manufacturer's Data Reports to be attached 196C, P.O. 45187878 / Ht. #153C, Nuts: P.O. 45204172 / Ht. #443C.

CERTIFICATE OF COMPLIANCE I certify thatihe statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed 6Aý Expiration Date N/A Senior Specialist Date November 13 20 07 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission-issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period V-1Y9-0 to

/ 0 -

X 91-0 7

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed.or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer

shallbe liable in any manner for any per*onal injury or property damage or a loss of any kind arising from or connected with

'this inspection.

i

/7 Inspector's Anature Commissions 7/ '

'Z"

  • /

National Board, State, Province, and Endorsements Date

/ /

tC/-

20 0 7

FORM 1/2-ADM-0801 F02 REV 3 RTL # A4.414-A Form No.

2057 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner First Energy Corp (NWE) 76 S. Main St. Akron. Ohio 44308 Date Sheet 10/22/07 1

of 1

(ADDRESS)

2. Plant Beaver Valley Power Station (NAWE)

Shippinglort, Pa. 15077 (ADDRESS)

3. Work Performed By BVPS Refueling (NAME)

Shippinonort. Pa. 15007 (ADDRESS)

Unit No.

1 ECP 03-0295-10 (200205616)

RePar/Re*acemeat Organi;4 PA No.. Job No.. etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A

4. Identification of System Reactor Coolant (Q1)
5. (a) Applicable Construction Code AISC 1963 Edition, 6 Addenda, WA Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity1989 (c) Applicable Section X1 Code Case(s) N/A

6. Identification of Components co.,eaod ASME ltemo'd.

code Name of Name of Manufiwrx National Board Othr yea or Stamped Compoaeat amafautw Serial No.

No.

Identification Boib lo-isfed (Yes or No)

CRDM Seismic Westinghouse

'N/A N/A IRC-R-l 1986 Corrected No Tie Rods

7. Description of Work Clevises and connectinq pins on each end of tie rod (6 tie rods total) were replaced.
8. Tests Conducted:

Hydrostatic* El Pneumatic* EL Nominal Operating Pressure E] Exempt 19 Other I]

Pressure psi Test Temp. __F "Record lest presswxe and unlperaxe

FORM i12-ADM-0801.F02 REV 3 RTL # A4.-414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Only tie rod end devises and associated Pins were Appocae zumKiacw's oaa PePods to be al Wed replaced. The tie rod/tumbuckle between the devis ends was reused.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements ofthe ASME Code, Section Xl-Type Code Symbol Stamp NIA Certificate of Authorization No.

. N/A Expiration.Date N/A 57'inncdiJ (Gdacko Date

/112 3,

2007 off Date o~'fwweahin.

Toe CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiter and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartfohd. CT have inspected the components described in this

.Ownee's Report during the pedod

-0 fo to

/0-A 0- 2

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing his certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shaD be alle in any marnneroray personal injury orpropery damage or a loss of any kind arising from or connected with ths inspection.

vL9 Commissions

-~,

+

"o,.4Z,? I WftianaI Board. State. Pnrx'ne. and EndorsemwNfts Date.

20 0

20 07

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2059 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY

  • o As Required by the Provisions of the ASME Code Section XI
1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron, OH 44308 Date Sheet 09/24/2007 1

of 1

(ADDRESS)

Beaver Valley Power Station (BVPS)

2. Plant Unit No.'

1 (NAME)

Shinninnnnrt PA 151377 (ADDRESS)

3. Work Performed By BVPS Construction Service (NAME)

Shioninonort, PA 15077 ECP 07-0145-01 (200223106)

RepaitrReplacernent Organization P.O. No., Job No.. etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date (ADDRESS)

4. Identification of System Quench Spray (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, N/A Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity.

1989 (c)

Applicable Section Xl Code Case(s): N/A

6. Identification of Components Coffected.

ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No Idemification Built Installed (Yes or No)

Pipe Stone &

N/A N/A QS-72 1976 Corrected No Webster Plug Nova Machine N/A N/A Ht. #718682 2000 Installed No

7. Description of Work Installed a 3/8" pipe plugi and seal welded.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* E]

Nominal Operating Pressure El Exempt Z Other r]

Pressure psi Test Temp.

OF

  • Record test pressure and temperature

FORM 1/2-ADM-080t.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back) 0 P-A-rLc K('r~rnci nfn~c Pn nrf tiniinhin

  • *.J.

I \\l*.l I I011\\*.*

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed Expiration Date Staff Nuclear Enaineer N/A Date October31, 20 07 vner s es gnee,

, e CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period L.. /

0 6 to

/ 0 -

. V - 0 ?, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

,o,-,,,

-J, ),ý,Y Commissions IT, d,

W,4, ) F'/

National Board, State, Province, and Endorsements Inspector';i*gnature Date

/0 20 20 0 '7

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2060 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron, OH 44308 (ADDRESS)
2. Plant Beaver Valley Power Station (BVPS)

(NAME)

Shippingport, PA 15077 (ADDRESS)

3. Work Performed By BVPS Construction Service (NAME)

Shinninconort PA 15077 Date 09/24/2007 Sheet 1

of 1

Unit No.

1 ECP 07-0145-01 (200261487)

Repair/Replacement Organization P.O. No., Job No.. etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date (ADDRESS)

4. Identification of System Quench Spray (03)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, N/A Code Case (b)

Applicable Edition of Section Xi Utilized for Repair/Replacement Activity 1989 (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Corrected.

ASME Removed.

Code Name of Name of Manufactuer National Board Other Yea.

or Stamped Component Manufacturer Serial No.

No.

Identification Built Insialled.

(Yes or No)

Pipe Stone &

N/A N/A QS-73 1976 Corrected No Webster Plug Nova Machine N/A N/A Ht. #718682 2000 Installed No.

7. Description of Work Installed a 3/8" pipe plug and seal welded.
8. Tests Conducted:

Hydrostatic* El Pneumatic* L]

Nominal Operating Pressure [] Exempt [

Other El Pressure psi Test Temp. _

OF Record test pressure and temperature

FORM 1/2-ADM-080).F02 REV 3 RTL. # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed --

Uý Expiration Date Staff Nuclear Enciineer N/A Date October 31, 20 07 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Rep6ort during the period

___-/__

k_

to

/ 0 -,,)-

Y-.

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions 7,/,

/-*;

National Board. State, Province, and Endorsements lnspeor's Signature Date 1/0

_?

, 20 0 '2

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

206i FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron. OH 44308 Date Sheet 12/17/2007 1

of 1

(ADDRESS)

Beaver Valley Power Station (BVPS)

2. Plant (NAME)

ShiDoinaDort. PA 15077 Unit No.

1 Work Orders #200212174, 200266335

3. Work Performed Shio (ADDRESS)

Repair/Replacemnent Organization P.O. No.. Job No., etc.

By BVPS Maintenance Type Code Symbol Stamp N/A (NAME) pincqport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date

4. Identification of System Chemical and Volume Control (02)
5. (a) Applicable Construction Code ANSI B16.5

-Edition, 1968 Addenda, N/A Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacernent Activity.

1989 (c)

Applicable Section XI Code Case(s):

6. Identification of Components Corrected.

ASME Removed.

Code Nameof Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Check Valve Velan N/A N/A 1CH-22 1976 Corrected No Disc Velan 7722 N/A Ht. #G2086 2003 Installed No

7. Description of Work Replaced valve disc and cover studs/nuts.
8. Tests Conducted:

Hydrostatic* El Pneumatic* El Nominal Operating Pressure El Exempt 0 Other E]

Pressure psi Test Temp. _

F Record test pressure and temperature

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A' FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Replaced Y/" cover Nuts: P.O. 45170756 / Ht. #X326, Applicable Manufacturer's Data Reports to be attached Studs: P.O. 47103695/ Ht. #X427.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Owier of Oweoreintioee, N/A Signed

-k Expiration Date Senior Specialist N/A-Date January 04

, 20 08 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued.by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 0

-D to

/0 6; 7

' and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements.of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Aaýý -1

., Zýy Commissions

-Z-, Al, 1/A ;

I Y National Board, State. Proince, and Endorsements lnspecif Signature Date 7/.

, 20

__X_

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

ý2064-FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT. ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner
2. Plant

-I FirstEnengy Corp.

(NAME)

Rhinninnnnrt PA 15S077 Date 5/23/07 Sheet 1

of 1

(ADDRESS)

Beaver Vallev Power Station Unit No.

1 (NAME)

Shippingport, PA. 15077 ECP-07-0059-03 (2002797511

3. Work Performed Ship (ADDRESS)

Repak/Repfacement Organization P.O. No.. Job No.. etc.

By BVPS Construction Type Code Symbol Stamp N/A (NAME)

Dingqort, PA. 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Safety Injection (Code Class Q2)
5. (a) Applicable Construction Code ANSI 831.1.0 1967 Edition, Summer 1971 Addenda, Code Case (b) Applicable Edition of Section XI Utilized for RepairlReplacement Activity.

1989 (c) Applicable Section Xl Code Case(s): N-491-2

6. Identification of Components Corrected.

ASME Rernoved.

Code Name of Name of Manufactuerer National Board other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built hwatted (Yes or No)

Pipe Support Stone & Webster N/A N/A I SI-I 10-R-19 1976 Corrected No

7. Description of Work Removal of diagonal brace and base plate to provide clearance for Expanded sump strainer
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* E]

Nominal Operating Pressure El Exempt M Other LI Pressure psi Test Temp.

° F

'Record test pressure and temperature

FORM I/2-ADM-080I.F02 REV 3 RTL # A4.41i4-A FORM NIS-2 (Back)

9. Remarks No Code data report available AppWicable Mwaftadums Data Repats to be attached CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

NIA Expiration Date NIA Signed Willis R. Garman - Enainee-,

O~er or Oimiers Deskinwi. Mite Date 9/26 -I 20 07 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CL have inspected the components descnrbed in this Owner's Reportduring theperiod i*/-.

f0 r.

to

/0--o,-

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures descaibed in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inwpcors ature Commissions

'-J'

-4 L-7 F'Y National Board, State, Proence, and Endorsements Date

/ 0a-?.-

, 20 02

FORM l/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2065 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C.

(NAME) 76 South Main Street -Akron. OH 44308 Date 10/15/2007 Sheet 1

of' 1

(ADDRESS)

Beaver Valley Power Station

2. Plant (NAME)

ShiDDinaport. PA 15077 Unit No.

1 Work Order # 200283320

.(ADDRESS)

3. Work Performed By BVPS Maintenance (NAME)

Shiopinqport, PA 15077 (ADDRESS)

Repair/Replacement Organization P.O. No., Job No.. etc.

Type Code Symbol Stamp Not Applicable Authorization No.

N/A Expiration Date N/A

4. Identification of System Residual Heat Removal (Class C)
5. (a) Applicable Construction Code ASME Section III 1968 Edition, N/A Addenda, N/A Code Case (b)

Applicable Edition of Section X1 Utilized for Repair/Replacement Activity.

1989 (c)

Applicable Section Xl Code Case(s) N/A

6. Identification of Components Corrected.

ASME Removed.

Code Nameof Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Heat Exchanfger Joseph'Oat 1832-1 368 IRH-E-IA 1969 Corrected Yes

7. Description of Work Replaced one flange stud and two nuts.
8. Tests Conducted:

Hydrostatic* El Pneumatic* LI Nominal Operating Pressure El Exempt Z Other LI Pressure psi Test Temp.

°_F Record test pressure and temperature

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Reports available. Previous NIS-2 Report: 1581, 1260, and 414. Replaced Applicable Manufacturer's Data Reports to be attached 1-318" Nuts: PO 45185711 / Ht. #R756-and Stud: P.O. 45189502 / Ht. #S663.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XA, Type Code Symbol Stamp N/A Certificate of Authorizatio N/A Expiration Date N/A Senior Specialist Date November 13,

2007 Sinned Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period L/ // 2 - 0 to 0 -,A

- d', and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall~be liable in any manner for any personal injury oriproperty damage or a loss of any kind arising from or connected with this..inspection...

Commissions

,.',*P,-'

7 1. /..&

/,4 da---' gy Inspýor's Signature National Board, State, Province, and Endorsements Date

./2/

7I/-

, 20 07

FORM 1/2*ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2067 FORM NIS-2 OWNER'S REPORT FOR IREPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner
2. Plant First Enerav Corn.

(NAME)

Shinninonnrt PA_

15077 Date 10/11/07 Sheet 1

of 1

Shinninnnnr.t PA 15077 (ADDRESS)

Beaver Valley Power Station Unit No.

1 (NAME)

Shinnincnoort-PA_ 15077 ECP-07-0149-01 (200261911)

3. Work Performed Ship w

(NAME)

Shioninooort. PA. 15077 (ADDRESS)

Repair Replacement Organizalton P.O. No. Job No.. etc-By BVPS Construction Type Code Symbol Stamp N/A (NAME) pinciport, PA. 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Reactor Coolant Pressurizer Safety Valve Piping (Code Class 1)
5. (a) Applicable Construction Code ANSI B31.1.0 1967 Edition, Summer 1971 Addenda,

-- Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 (c) Applicable Section X1 Code Case(s): N/A

6. Identification of.Components Corr-eded.

ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped.

Component Manufacturer Serial No-No.

Identification Built Installed (Yes or No)

Pipe Support Stone & Webster N/A N/A 1RC-350-H-36 1981 Corrected..

No

7. Description of Work Add plates that are welded to the pipe flan-ge and the support to restrict movement of the pipe when safety valve is removed.
8. Tests Conducted:

Hydrostatic* LI Pneumatic* E]

Nominal Operating Pressure E] Exempt M Other LI Pressure psi Test Temp. _°Fr

  • Record test pressure and temperature

FORM I/2-ADM-080.F02 REV 3 SRTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code data report available Applicabe M eufadhur's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Willis R. Garman - Engineer Date 10/1

, 20 07 Owner or Owners Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT.

have inspected the components described in this Owtier's Report during the period

-'-/P--

to

" 3 / K ~

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable i'n any manner for any personal injury or property damage or a loss of anykind arising from or connected with this inspection.

Commissions "J-.

/ 1 ), 3 F National goard, State, Province, and Endorsements Inspect ;9gnature Date

/

0 -

/

, 20 07,

FORM 1/2-ADM-080I.F02 REV 3 RTL # A4.414-A Form No.

2068 FORM NIS-2 OWNER'S REPORT FOR RIEPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI.

1. Owner
2. Plant First Energy Corp.

(NAME)

Shippinqcport, PA. 15077 Date Sheet 10/1/07 (ADDRESS)

Beaver Valley Power Station Unit No.

1 of 1

1 ECP-07-0149-02 (200261912)

(NAME)

Shippingport, PA. 15077

3. Work Performed Ship (ADDRESS)

Repair/Replacement Organization P.O. No., Job No. etc.

By BVPS Construction Type Code Symbol Stamp N/A (NAME) pincqport, PA. 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Reactor Coolant Pressu'rizer.Safety, Valve Piping (Code Class 1)
5. (a) Applicable Construction Code ANSI B31.1.0 1967
Edition, Summer 1971 Addenda, Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity.

1989 (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Correcte&

ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Buith Installed (Yes or No)

Pipe Support Stone & Webster N/A N/A 1RC-350-H-38 1981 Corrected No

7. Description of Work Add plates that are welded to the pipe flange and the support to restrict movement of the pipe when safety valve is removed.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* LI Nominal Operating Pressure EL Exempt 0 Other L]

Pressure psi Test Temp.

IF

'Record test pressure and temperature

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No'Code data reoort available Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Willis R. Garman -Engineer 1

'f, Date 10/1

, 20 07 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or.Province of Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owner's Report during the period Y'* /9 0

to

/

-/

o 0

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector's Silature Commissions

-T,-d, 1ý` 4A, z -

National Board,*State, Province. and Endorsements Date

/

0

.2, 20 (9 P

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2069 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner
2. Plant First Enerav Coro.

Date 10/1/07 (NAME)

Shippinqport;PA.

15077, Sheet 1

of 1

(ADDRESS)

Beaver Vallev Power Station Unit No.

1 (NAME)

Shippinciport, PA. 15077 ECP-07-0149-03 (200261913)

3. Work Performed Ship (ADDRESS)

Repair/Replacement Organization P.O. No.. Job No., etc.

By BVPS Construction Type Code Symbol Stamp N/A (NAME) pinoqport, PA. 15077 Authorization No.

N/A (ADDRESS)

Expiration Date N/A

4. Identification of System Reactor Coolant Pressurizer:Safety. Valve Pipingq (Code Class 1)
5. (a) Applicable Construction Code ANSI B31.1.0 1967 Edition, Summer 1971 Addenda,

-- Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity.

1989 (c) Applicable Section Xl Code Case(s): N/A

6. Identification of Components Correted.

ASME Removed.

Code Name of Name of Manufacture National Board Other Year or Stamped Component Manufacturer Serial No.

No-Idemification Buil Installed (Yes or No)

Pipe Support Stone & Webster N/A N/A IRC-350-H-40 1981 Corrected.

No 4

I

+

4-1 I

7. Description of Work Add plates that are welded to the pipe flangqe and the support to restrict movement of the DiDe-when safetv valve is removed.
8. Tests Conducted:

Hydrostatic* LI Pneumatic* LI Nominal Operating Pressure E] Exempt 0 Other LI Pressure psi Test Temp.

IF

  • Record test pressure and temperature

FORM i/2-ADM-0801.F02 REV 3 RTL # MA4.14-A FORM NIS-2 (Back)

9. Remarks Nor'Code data report available Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Willis R. Garman - Engineer Date 10/1 20 07 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT.

have inspected the components described in this Owner's Report during theperiod 0(/ 0 Y(o to

/ 0 /A*-

2 and statethat to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or.a loss of any kind arising from or connected with this inspection.

J(

-J

'Zo" 1,/

Commissions -

Id, Z-..

V National Board, State. Province, and Endorsements Inspector's,,~t Date

/ d -/"

  • 2

, 20 (9 2

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2070 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron, OH 44308 Date 11-07-2007 Sheet 1

of 2

(ADDRESS)

Beaver Vallev Power Station (BVPSI

2. Plant Unit No.

1 (NAME)

Work Order #200205203 Shinningnort PA 15077

3. Work Performed Ship (ADDRESS)

Repair/Replacement Organization P0. No.. Job No.. etc.

By BVPS Valve Team Type Code Symbol Stamp N/A (NAME) pinciport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date

4. Identification of System Steam Generator Blow Down (Q2)
5. (a) Applicable Construction Code Section III 1980 Edition, S'80 Addenda, N/A Code Case (b)

Applicable Edition of Section XI Utilized for Repair/Replacement Activity 1989 (c)

Applicable Section Xl Code Case(s): N/A

6. Identification of Components Cot-eeed.

ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.-

No.

Identification Built Installed (Yes or No)

Gate Valve Borg-Warner 75595 N/A TV-I BD-It01CI 1982 Corrected Yes Bonnet Flowserve 87987-1 N/A Ht. 1187987 2006 Installed Yes I

+

+

1 4

+

I

7. Description of Work Replaced valve bonnet and body/bonnet studs & nuts.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* LI Nominal Operating Pressure 0 Exempt El Other En Pressure psi Test Temp.

_F

'Record lest pressure and temperature

(.

FORM s/2-ADM-080..F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Code Data Report attached. Replaced 5/16" Studs: P.O. 45138921 I Ht. #P441: Nuts:

Applicable Manufacturer's Data Reports to be attached P.O. 47075835 / Ht. #P728. Valve is ASME Section III but is installedinto an ANSI B31.1 ninina system.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Auhorizatio N/A Expiration Date N/A Signed Senior Specialist Date November 08

, 20 07 L

Owner oJFNner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania andemployed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period r-

- 0

  • to

/

7

¢"//

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

tnspeX rn SignatureNainloaSttronendEosmns Commissions

.L'-/

/3/4f

-J'

'Y National Board, State, Province, and Endorsements Date

/;/-

11.20 -

, 20 0 7

"(Pige 8, of 19)

FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. I of 2

1. -Manufactured and certified by Flowserve Co.roratiou/ 1900 South Saunders Street. Raleigh NC 27603 (Name and Addres o NPT CeWt re aif dde
2.

Manufactured for First Ener*y Cor / PO Box 6100 Johnstown, PA 15907-6100 (tm "

an&d Or Pwdeu

3.

Location of Installation First Enery Corp/Beaver Valley Nuclear Power Plant/ Route 168 Shippingport. PA 15077

4.

Type:

434HAB6-001 Rev E (dr-vf m.)

5.

ASME Code, Section Ill, Division 1:

6.

Fabricated in accordance with Const only)

(Name and Adoein)

ASME SA105 N/A N/A 2006 (mati. se, no.)

(tW.A.e wen0)

(CRN)

(yew' built) 1980 Summer, 1980 2

N/A

  • K-. ( )

addd

)

2_TdsI

)

(Code Case no.)

Spec, (Div. 2 N/A Revision N/A Date N/A (an.)

7.

Remarks:

Bonnet for a 3" 600# Globe Valve S.O. 35977 8.

9.

Nom. Thickness (in.)

N/A Min. design thickness (in.)

PER#4 Dia. ID (ft & in.)

N/A When applicable. Certificate Holders" Data Reports are attached for each item of this report Length overall (ft & in.)

N/A Part or Appurtenance National Serial Number Board No.

In Numerical Order (1) 87987-1 N/A (2)

(3)___________

(4)

(5)

(6)

(7)

(8)

(9)

(10)__

(12)

(13)

(14)

(15)

(16)

(17)

(18)

(19)

(20)

(21)

(22)

(23)

(24)

(25)

Part or Appurtenance Serial Number National Board No.

In Numerical Order (26)

(27)

(28)

(29)

(30)

(31)

(32)

(33)

(34)

(35)

(36)

(37)

(38)

(39)

(40)

(41)

(42)

(43)

'(44)

(45)

(46)

(47)

(48)

(49)

(50')

00

10.

Design pressure 1480 psi.

Temp.

I (50) "F.

Hydro. Test pressure N/A

-At temp. 'F

'Supplemental information in form of lists, sketches or drawings may be used provided (t) size is 8-1/2" x 11", (2) information in items 2 and 3 on this Data Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(p~age 9 of 19)

FORM N-2 (Back-Pg. 2 of 2)

Ceulficrate Holders Serial Nos. 87987-1 CERTIFICATION OF DESIGN Design specification ceifed by W. L RAMSDEN Pt Stat PA Reg. no.

28975 Design Report certified by P.E State Reg. no.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these) pARTS Conforms to the rules of construction of the ASME Code,Section III, Division 1.

NPT Ceulificate of Authorization N1563 EXpI5s 11126/2009 No.

Date I~

AO10 Name Flo~wserye Corporation Signed__

(NPT Ce9ltce Holde"a" (auoized repe-i)

CERTIFICATE OF INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT of Hartford. Connecticut have inspected these items described in this Data Report on J 7-1 I7-f 1

, and state, that, to the best of my knowledge and belief, the Certificate Holder has fabricated.these parts or appurtenances in accordance with the ASME Code,Section III, Division 1. Each part listed has been authorized for stamping on the date shown above.

By signing this,certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal. injury or.

property damage or loss of any kind arising from or connected with this I"pecton.

Date G~~Jf Sg e

-5 ;

1.

ommissions 72 0 (*luze Signred.(id noseut) m tte sV mdn Z

(A'AhmizedIrls"41clar)

(Naft B& &Mxat

) and stite. prov. and no.)

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2071 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C (NAME) 76 South Main Street -

Akron. OH 44308 Date Sheet 10-29-2007 (ADDRESS)-

1 of 1

1

2. Plant Unit No.

Beaver Vallev Power Station (BVPSI (NAME)

Shiopinqoort, PA 15077 Work Order #200221342

3. Work Performed Ship (ADDRESS)

Repair/Replacement Organization P.O. No., Job No.. etc.

By BVPS Valve Team Type Code Symbol Stamp N/A (NAME) pinoport, PA 15077 Authorization No.

N/A (ADDRESS)

Expiration Date

4. Identification of System Steam Generator Blow Down (Q2)
5. (a) Applicable Construction Code Section III 1980 Edition-S'80 Addenda, N/A Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity-1989 (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Correled-ASME Removed.

Code Name of Name of Manufacturer National Board Other Yeiar or Stamped Component Manufacturer Serial No.

No.

Idetification Built Installed (Yes or No)

Gate Valve Borg-Warner 75598 N/A TV-IBD-l0lC2 1982 Corrected Yes

7. Description of Work Pn nloolh~~/rnnfat ca.rkt 9. n,

~~~.ttJ

~

y JJ I

f o~JOSn*I4C

8. Tests Conducted:

Hydrostatic* El Pneumatic* L] Nominal Operating Pressure LI Exempt Other [L Pressure psi Test Temp.

°F

'Record test pressure and temperature

FORM l/2-ADM-0801.F02 REV 3 RTL # A4.414-A

.FORM NIS-2 (Back)

9. Remarks No Code Data report available. Previous NIS-2 Data Report No: 1427. Replaced 5/16" Applicable Manufacturer's Data Reports to be attached Studs: P.O. 45138921 / Ht. #P441 Nuts: P.O. 47075835 / Ht. #P728. Valve is ASME Section III but is installed into an ANSI B31.1 piping system.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A

'Certificate of AuthorizatiooNe-,

N/A Expiration Date N/A Signed Senior Specialist Date November 08

, 20 07 Owner o6Uwer's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owner's Report during the period

'/-

to

/O -2.-1

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Jý,-,ý-J L., it"

/

Commissions Y

National Board, State, Province, and Endorsements inspector'sp6nature Date 2

/

00

, 20 0'7

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2072 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C.

(NAME) 76 South Main Street - Akron, OH 44308 Date 10/31/2007 Sheet 1

of 1

(ADDRESS)

Beaver Vallev Power Station

2. Plant Unit No.

1 (NAME)

ShiDoinaoort. PA 15077 (ADDRESS)

3. Work Performed By BVPS ValveTeam (NAME)

ShiooinoDort, PA 15077 Work Order #200213878 Repair/Replacement Organization P.0. No., Job No., etc.

Type Code Symbol Stamp Not Applicable Authorization No.

N/A Expiration Date N/A (ADDRESS)

4. Identification of System Main Steam (Q2)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, N/A Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity.

1989 (c) Applicable Section X1 Code Case(s) N/A

6. Identification of Components Corrected.

-ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Idetification Built Installed (Yes or No)

Globe Valve Masoneilan H-49378-264 N/A HCV-IMS-104 1976 Corrected No Plug Masoneilan-N/A N/A HT #14464 2006 Installed No Dresser

7. Uescription ot Work

.Replaced stem assembly with. Plugq 8: Tests Conducted:

Hydrostatic* El Pneumatic* LI Nominal Operating Pressure El Exempt Z Other LI Pressure psi Test Temp.

O F

  • Record test pressure and temperature

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code Data Report available. Previous NIS-2 Data Report:"1568, 827, and 149.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed

,I.z

' '*J Expiration Date N/A Senior Specialist Date November-14, 20 07 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period.

0,'(

to

("0 -' *- V -

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XA.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

I Commissions

-3r-Inspector'ýOgnature National Board, State, Province, and Endorsements Date S,20 07

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2073 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C.

(NAME) 76 South Main Street - Akron, OH 44308 Date Sheet Unit No.

10/15/2007 1

of 1

1 (ADDRESS)

BeaverValley Power Station

2. Plant (NAME)

Shinninnnnrt PA 1 F077 Shinningnort PA 15677 (ADDRESS)

3. Work Performed. By.

BVPS Valve Team (NAME)

Shinninrnnnrt PA 15S077 Work Order #200207316 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp Not Applicable Authorization No.

N/A Expiration Date N/A (ADDRESS)

4. Identification of System Quench Spray (Q3)*"

5, (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, N/A Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 (c)

Applicable Section Xl Code Case(s) N/A

6. Identification of Components Corrected, ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Mamufacturer

. Serial No.

No.

Idenification Buih Installed (Yes or No)

Pipe Flange Stone &

N/A N/A QS-2 1976 Corrected No Webster

7. Description of Work Replaced piping flange studs and nuts.
8. Tests Conducted:*

Hydrostatic* El Pneumatic* E]

Nominal Operating Pressure [L Exempt 0 Other --

Pressure psi Test Temp.

O F

  • Record test pressure and temperature

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.4I4-A FORM NIS-2 (Back)

9. Remarks No, Code Data Report available. Replaced flanqe 7/8" Studs: P.O. 45172981 Ht. #X374:

Nuts: P.O. 45173478 / Ht. #X391.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report, arecorrect and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Senior Specialist Date November 13 20 07 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period to

/0 - '-0,3 and'state that to the best of my knowledge and belief,*the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.. Furthermore, neitherithe inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions A<

1 National Board, State. Province, and Endorsements Inspector's,%gnature Date

/f (_W_

20 0 '?

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4.41l4-A Form No.

2074 FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner
2. Plant First Energy Corp.

(NP*A.)

Shippingport. PA. 15077 Date 10/3/07 Sheet 1

of I

(A3OESS)

Beaver Valley Power Station Unit No.

1 Shippxinpomt, PA. 15077 ECP-07-0300-01 (200284331.)

3. Work Performed Ship (AOIRESS)

RepairAtaemen6 Orgaruzaaion P.O. No. Job No. etc.

By BVPS Construction Type Code Symbol Stamp N/A (NAE) pincport, PA. 15077 Authorization No.

N/A (EiDOReSS)

Expiration Date N/A

4. Identification of System Recirculation Soray (Code Class 2)
5. (a) Applicable Construdion Code ANSI B31.1.0 1967 Edition,. Summer 1971 Addenda, Code Case (b)

Applicable Edition of Section XI UfJirzed for RepailReplacemnent Acfivity.

1989 (c) Applicable Section XI Code Case(s) N-491-2

6. Identification of Components Correed.

ASME Rý"oed.

Code Name of Name of Mmfacu Nationa Board othr Ycw re Slampod C-ooe MauSFm Saial No No.

Ideoiicoion Buih Instaled (Yo or No)

Pipe Support Stone & Webster N/A N/A IRS-S-I 1976 Corrected No

7. Description of Work Remove columns adjacent to Containment finer and move columns on opposite side of platform to provide clearance for new sump strainer.
8. Tests Conducted:

Hydrostatic* F]

Pneumatic* E]

Nominal Operating Pressure [] Exempt N Other 0 Pressure psi Test Temp.

_F

FORM I/2-ADM-0801.F02 REV 3 RTL it A4.414-A FORM NIS-2 (Back)

9. Remarks No Code data report available Apokice ManUbCAdWS D=t Rýwt to We attached CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Willis R. Garman - Fnaineer Date 10/3

.20 07 Owe or Owrwes Deskinee. TMe CERTIFICATE OF INSERVICE ISPECTION I, the undersigned, holding a valid commission issued by the National Boad of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HBT CT of Hartford. CT have inspected the componelts described in this Owner's Report dudng the period to

/0

.,.t

- 07

.and state lhat to the best of my knowledge and belief, the Ovmer has perfomed examinations and taken corrective measures described in this Owners Report in accordance vlth the requirements of the ASME Code. Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owne's Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal knury or property damage era loss of any kind arising from or connected with this inspection.

ComI sons J;

~-7KA'""' A-ý -Kf Date

/'0-,A-- --

, 2o0

^7

FORM 1/2-ADM-080F02 REV 3 RTL # A4.414-A Form No.

2076 FORM NIS-2 OWNER'S REPORT FOR REPAIRSlREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron, OH 44308 Date 11/15/2007 Sheet 1

of 1

2. Plant (ADDRESS)

Beaver Valley Power Station (BVPS)

(NAME)

Shippincwort, PA 15077 Unit No.

1 (ADDRESS)

3. Work Performed By BVPS Construction Service (NAME)

Shippinqport, PA 15077.

(ADDRESS)

Work Order #200200160 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date

4. Identification of System River Water (Q3)
5. (a) Applicable Construction Code ANSI B31.1 1967 Edition, S'71 Addenda, N/A Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 (c). Applicable Section Xl Code Case(s): N-416-2

6. Identification of Components Corrected.

ASME Remo-ved.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Ball Valve BNL Industries B021016-1-8 N/A IRW-132-2003 Corrected No

7. Description of Work Repaired pinhole cavity inside valve end piece.
8. Tests Conducted:

Hydrostatic*

]

Pneumatic* D Nominal Operating. Pressure N Exempt [L Other EL Pressure psi Test Temp. _°OF

'Record test pressure and temperature

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks No Code'Data Report available. Previous NIS-2 Data Report No: 1571.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.

  • Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed 1

Expiration Date Sr~ninr 5qnprnii~-tl N/A Date November 15

, 20 07 Senior Snecialist

\\

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford. CT have inspected the components described in this Owner's Report during the period 0 ('

to f0 --*Z ( -

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

'~

Commissions

/

14

,1--3 8-'Y National Board, State, Province, and Endorsements lnspecv'5gnature Date

/a/t (F -

,20 0'2

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A Form No.

2077 FORM NIS-2 OWNER'S REPORT FOR REPAIRSlREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner
2. Plant First Enerov CorD.

(NAME)

Shinninonort Pza 150377 Date 10/16/07 C

Sheet 1

of 1

Shinningnort Pa 15077 (ADDRESS)

Beaver Valley Power Station Unit No.

1 (NAME)

Shinninonort Pa. 15077 ECP 07-0310 (ADDRESS)

3. Work Performed By Design Engineering (NAME)

Shinninonort Pa. 15077 RepairlReplacement Organization P.0- No., Job No_ etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A (ADDRESS)

4. Identification of System Feedwater System - (Q2)
5. (a) Applicable Construction Code ANSI 631.1 1967 Edition, S71 Addenda, None Code Case (b)

Applicable Edition of Section Xl Utilized for Repair/Replacement Activity.

1989 (c)

Applicable Section Xl Code Case(s): N/A

6. Identification of Components Corrected, ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No-Identification Built Installed (Yes or No)

WFPD-22 Southwest None None None 1970 Rerated No Fabricating &

Welding Co.

WFPD-23 Southwest None None None 1970 Rerated No Fabricating &

Welding Co.

WFPD-24 Southwest None None None 1970 Rerated No Fabricating &

Welding Co.

7. Description of Work Rerating of feedwater piping between feedwater isolation valves and steam generators.
8. Tests Conducted:

Hydrostatic* L]

Pneumatic* LI Nominal Operating Pressure EL Exempt M Other El Pressure psi Test Temp.

_F

'Record test pressure and temperature

FORM 1/2-ADM-080.F02 REV 3

...1 11 1

ý 1 11 1 RTL 4 A4.414-A FORM NIS-2 (Back)

9. Remarks Nonie. Exempt from Pressure Testing because the piping is being rated to a lower Applicable Manufacturer's Data Reports to be attached Pressure.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Ex piration Date N/A Sinned

...OV'5O r Owner's Designee. Title Nuclear Engineer Date October 17

, 20 07 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 0

to

/0

-/ 7 0- 7

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XA.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

-T W,

2 V

Inspect*}AKgnature National Board. State, Province, and Endorsements Date

/, 0

/ ? -

,20o

FORM 1/2-ADM-0801.F02 REV 3 RTL # A4,414-A Form No.

2086, FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI
1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron. OH 44308 Date Sheet 11/29/2007 1

of 2

(ADDRESS)

Beaver Valley Power Station (BVPS)

2. Plant Unit No.

1 (NAME)

ShiDninonort. PA 15077 Work Order #200287233 (ADDRESS)

3. Work Performed By BVPS Maintenance (NAME)

Shioninaoort. PA 15077 Repair/Replacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date (ADDRESS)

4. Identification of System Ventilation/River Water (Q3)
5. (a) Applicable Construction Code Section VIII 1971 Edition, S72 Addenda, N/A Code Case (b)

Applicable Edition of Section X1 Utilized for Repair/Replacement Activity, 1989 (c)

Applicable Section XI Code Case(s): N/A

6. Identification of Components Correted.

ASME Removed.

Code Name of Name of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No)

Heat Exchanger York 1-2239 46531 IVS-E-4B 1972 Corrected Yes

7. Description of Work Replaced end bell baffle plate and repaired areas of corrosion.
8. Tests Conducted:

Hydrostatic* E]

Pneumatic* E]

Nominal Operating Pressure [] Exempt [

Other E]

Pressure psi Test Temp.

_o_ F

'Record test pressure and temperature

FORM 1/2-ADM-0801 F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks U-1 Data Report attached. The.tube/end bell section of the heat exchanger was exempt Applicable Manufacturer's Data Reports to be attached to ASME Section VIII and was made to commercialarade. ANSI B31.1 was used as Construction Code for the weld repairs. Previous NIS-2 Data Report Nos: 1590. 1086. 348. and 196.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A N/A Expiration Date N/A Signed Date November 29

, 20 07 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and.employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the pedod

!/-/i'? -0 G to

[(0 -

(/~

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code; Section Xt.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner. for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Insp-ectosgnature Commissions,J

9Th -,4 d

National Board, State. Province, and Endorsements Date

//-3 00-1,20 0 ?

I

ý6i

.11 VIi F."1110 11-1 MANUFACTURERS" DATA RlEPORT FOR PRESSUJRE VESSELS F6-20.K A,~

ýrd by the Provi~tionti of the ASM Erode Riles. Sec. ion VIII1. fliviftton I I Sio.111tdclted by vAORK Di 1 BORG-WARNER CORPORATIONs YORK, PENNSYLVANIA -U.S.A.

.yNMm esn and adie~(faniiitue) 2.Matiifitcluted fo B1EAVER VALLEY POWER STAT.ION.. S!1PPýINGPORT, PENNSYLVANIA

_J9ý--

KHon _lt.x~

I~No Nail. fld. 4o. 4 6 5 3 1 yt. Retailt 7

titriri.1er vti.)

(Iak, J;,ckeledjlcm~ F.Mh.)

brrafi.erild)

(Sae& State No.

I-,heomplelcild flld SIiglc' wa.ll vcN~clx (itcuh a% air t1anks). jackct% of jacketed vmrs rcko etcthnc I(Kited field Spre. No.)

Fiig~tir F.11411 Sprc.Nlin.T.S.)rite

.S.MS Seamless No.____KT

-NoSeind No fiolly10 scie W;1111 (Wldt~itt.StiteldpItit)

(Yes orf Nail' (Spilt or Vomphtte),

(Yet or NO) verse side tit'

(;fill.%111 R. U. _________Sectioned No.of CoetrscA 1

fo

6. Illl'.

S 1 st41 laclviit I.S.

(hl MalaCrial U.S.

C :%%:n row Knuckle Elliptical Conical.

Iamslietphrical fla Side it)

Prre'etc (I.."cII i endis)

Meiknes, l4.idju alt dius R~atio Ae nl aii limtt(oco ocr I.hk.Iolls ised Other fastertni t(t3lCtial. Spec. N.... is.S.

Stle. Numbe~r)

(Describe air Attach Sketch)

S 7A N'10 1A o

S It hollow

_Attachment Pitch X

Diarn.-

Sllia (Site oif Matti (T-hreaded. Welded)

(ý~-I -liS.)

(Vert.)

(Nominal)

(I le c atbe as ae e & is eld.

har. t tc..

Itf bar. Itive d imenusions. if bulltedl describe or site Lh I

('a. notrum IC:d Icr ma'1-1v Nlit Terttp.(1whcn, Plncu natlc 'te test AlmtA'sIt'C %ork ne Pecs, '..300-lasei, 11 114 teip..2.%'.:' leci thtan -2(r)

P1 I1hUU rv~

e,..-... 375-.

p 10(. _F1it

'IIISIt

-IS:

12sttionary.. \\.litcriatl.... S.t~eei......

Diato..3/ H'.

Thickncss I~ In. Attachment -- We I dad-(Klint & Sliec. N,,.) (Sutelect to I'c%!iurt)

-(Welded, Untoetd)

Ii lall og.

St

.tIcrial Dia.ni.

Ili.

T'hickne~s it. AlIlachnicni Stain Ies~t, SA-M mI& 4 It.

J4tl.S

___il

_____C)I

..I4. Ili.

Ihick ncsc tI_6BflG or Gage Nkilnhter.J5v...

-tp Strai ght_....

(Kind & Spec. N-.)

f'ýtarh i I)

-Iotell

-12 I l

ti i cr l clI ir lat'tic,l~ hiiitfic t, of tckkvted vcessel%. far chain nels t, heal exchanger,..

Ni'minal tCorrilslon

12. Sill:1 I I Maleriil n~.

'licI-ne%q In. Allow.ance

-i...n. lDiain.

Iti.

-Ilij.

l~engtl I. v if,..

tKind end Sri-i. N',.) (Fiff.

wc I<11. & Stw. Sta.

1.S.)

Iiiti e

1 1. St AMt.

f.,l tR E

11"ficicn, y~t~~l~

-stlesa I

.rll

1.

I I.'

___________S,:Alion%:d _____

Nit. ufcuit

~caesstl 4.IttllN

(.t

.,rl:,I

.S..

ilii Wtilerlil 1.5 (0_

... c Material.

.§t.

Kr..

,ii. Kn ic e itllipt ical Colittat lI fltnistthetical Ilst Side i, t sc ti-i S u tcautt l).'ut~ilIt tit Udiuk Rai Apex-.---- Ange adus iaetr...-ve It rclr aic.2Iht...

tii~ls uWdqI.i I....

li______

(5t.tleriai. Spec, N,-

I.IS. Sile. Nii1titet'

)

i~evrihe rasl h1311 Sketch I

15.

('fIk,lri :ed tT1,11' 15~l.

M'in.

tell.ip. ivawhen.

ya tnnsl~

Leak test alloitwalle stok Ing Preiss..J5 i

ti ma.

itemp 1J50F lcii than -20')

PRm

.100 psi.

l6. SAFFINi VALVEi ou'tUT.ITS: Numbiter

.~..

___site ALi

.ocaiion -Near end of shell

17..NO/ZZLKS Ptirpiose t I nite.

Reinforcemnten Iow (htitlil.lhtain t Ntznt-Cl D~ianai. or Suc "I y lie Material iThickific".

I Material Atiachvid Inet4"__

Pip SA-53-8 Sch..40.

SA-515-70

-WMelIded..

Oule 411 Ptp A-53=z8.

A.ch 40 SA-515-70 M9jld ead.

_Equa.L L

I -1 L4 CQ jp I i q SA 105-2 3,QQojo, b_

weIL~e_ýd

!fpomstctd heal-ircated.

Li,st unde: remarki other internal or external pressures with coincident talenipralure when applicable.

~lo (vr)

N. B. 146531

18. INSPECTION Manholes, No.______________________ Size ____I_______

Location__I OPENINGS:

llattdholei. No.

Size Location Threaded."*

Siz+

Locatn ion

19. SUP'ORTS:

L skirt

.,__,_,_o_'

Lug,.

Lgs

-,a, he atNe l

NO)(+Hub)

)

t e(srib))

'0. t EMARtaSt.

16" x 7' Condenser = Reffrigrant-No.-orros~yeSeclt*L___

... Tube section code examt U-I(d)(I2 415 ronn -

weld Andt

':HvdrnrtAtlr-Amýc+

d'ifl ei--

hafen,-a 1%,hin SA-24 _naterial conforms to IKG-9 C

¢ownturute_

u n rthe provisions of UG-90 (cOW2 (Dte1 descrptplon of p-.rpose of the weief. as Air Tank. After Cooler. Jacketed Cooker. etc. State c.,roslnts of each part.)

We certify that the statements made.in this r-porr are correct and that all details of design. materia construction, and w-ork rtnhkip of this vessei conform to the ASI'E C:de for PrO*tissur VesselsSection II D

ae,-.Aiu us9 7ine YcORK DIMISON 'BOAG-'WAR~

1972 Si-ned-M"'"

ie Itr,.r.,

.,f A,,,r,,.

,N,,.

87.

r r

__Senior Engineer CERTIFICATE OF SiiOI5 INSPECTION VESSEL MADE Uy -:YORK, DIV/IS.IOH BORG-WARt(ER (OIgATIOH,

YORK, PENNA.

- U.S.A.

I. the undetalgtid. holding a valid commlsslon Issued by tb NattiOnal Board of Bloiler and Pressure Vessel Inspectors and/or the Stateor pco.rince PennsyIvaniidemployed by Hartford Stea. m Boiler Inso. A Ins. Co.

o

__l.artftard..Connecti-ut have inspected the pressure vessel described in this manufacturer's drtA ;,,rtqon May. 16

+I i

n4* sate that to the best of.my knowledge and belief. die.auusc-tutor has constructed this pressure vessel In accordance with the applicable sections of the ASME Boiler and Pressure Vessel Code.

By signing this certificate neither-the Inspector nor his employer makes any warranty, expressed or Implied, concering the pressure vassel described in this manufacturer's diae report. Furthermore. neither the Inspector nor his employer shall. be liable to any msnner for any personal injury or property damage or-a lose of any kind arising from or connected with this inspection.

Date August 7 19 72

+nNatl, Bd Comm. #3695 Inspectors Slgnature NAIrl 1 4

-0,],

SUM, I'rl-

ý CERTIFICATE OF FIELD ASSEMBLY INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and/or the State or Province and employed by of have compared the statements in this manufscturer's data report with the described prtasure y.ssel and state that parts referred to as data items

.not included in the certificaie`' if shop Inspection have been Inspected by me rid that to the best of my knowledge and belle'f the manufacturer has constructed and assembled this -pressure vessel in accordance with the applicable sections of the ASME Boiler and, Pressur Vesasel Code. The described vessel +ws linspeted and subjected to a hydrostatic test of psi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied. concerning the pressure vessel describedin this manufacturer's date report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for :any personal Injury:or property -damsge or a loss of any kind arising from or connected with this inspection.

Data 19.

Commissions irnapect.,Ia'Sic--,-

Nl*. ~o ri Slate. llfe-+t*,nc

-rli IV~'

FORM 1/2-ADM-080.F02 REV 3 RTL # A4.414-A Form No.

2087 FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner F.E.N.O.C (NAME) 76 South Main Street - Akron, OH 44308 Date Sheet 11113/07 1

of 2

(ADDRESS)

Beaver Valley Power Station (BVPS)

2. Plant Unit No.

1 (NAME)

Shiooinooort. PA 15077 (ADDRESS)

3. Work Performed By Beaver Valley/Westinghouse (NAME)

Shippingport, PA 15077 (ADDRESS)

PO #7024829 Repair/RePlacement Organization P.O. No., Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A

4. Identification of System Reactor Coolant System
5. (a) Applicable Construction Code ASME Section III 89 Edition, No Addenda,*:

N/A Code Case (b) Applicable Edition of Section XA Utilized for Repair/Replacement Activty 1989 Edition, No Addenda (c) Applicable Section Xl Code Case(s): N/A

6. Identification of Components Corrcaed ASME
Removed, Code Name of Naoe of Manufacturer National Board Other Year or Stamped Component Manufacturer Serial No.

No.

Identification Built Installed (Yes or No) 1RC-E-1C Westinghouse NP030651/

84 N/A 2005

,Corrected Yes 3MB2

7. Description of Work Installed two tube plugs (Alloy 690) in one SG tube. Replaced hot leg primary manway stud (#CH7).
8. Tests Conducted:

Hydrostatic* L]

Pneumatic* L] Nominal Operating Pressure H Exempt L]

Other E]

Pressure N/A psi Test Temp.

N/A 0 F

  • Record test pressure and temperature

FORM I/2-ADM-0801.F02 REV 3 RTL # A4.414-A FORM NIS-2 (Back)

9. Remarks Primary side work order - 200211850 Applicable Manufacturers Data Reports to be attached Performed VT-i examination on all studs. nuts. washers, insert Dlates & aasket seatina surfaces.

Performed Vr-1 examination on all studs nuts washe insert dates & oasket seafino surfaces CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed Gary Alberti, Project Manager

,*I4 t"

Owner or Ovner'es Designee, Title Date

( 2

, 20 0___

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pennsylvania and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 0,P to

(

Y

).

2

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

3c-ý -J -z ýý Commissions de 7 F XA

? e-V National Board, State. Province, and Endorsements inapedtoisy'hatur Date

/I( --?0-S,20 6 ?