IR 05000445/1997006

From kanterella
Jump to navigation Jump to search
Insp Repts 50-445/97-06 & 50-446/97-06 on 970428-0502. Violations Noted.Major Areas Inspected:Operations & Plant Support & Assessment of Licensed Operator Requalification Program
ML20148H456
Person / Time
Site: Comanche Peak  
Issue date: 06/06/1997
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
Shared Package
ML20148H433 List:
References
50-445-97-06, 50-445-97-6, 50-446-97-06, 50-446-97-6, NUDOCS 9706100194
Download: ML20148H456 (13)


Text

.

>,.

.. +.

ENCLOSURE 2 U.S. NUCLEAR REGULATORY COMMISSION

REGION IV

v Docket Nos.:

50-445, 50-445

License No.:

NPF-86, NPF-87 l

' Report No.:

50-445/97-06,50-446/97-06 i

Licensee:

TU Electric-1 Facility:

Comanche Peak Steam Electric Station, Units 1 and 2 Location:

FM-56 Glen Rose, Texas Dates:

April 28,1997 through May 2,1997 Inspectors:

Thomas Meadows, Reactor Engineer, Operations Branch Ryan Lantz, Reactor Engineer, Operations Branch Vonna Ordaz, Resident inspector, Operations Branch Approved By:

John L. Pellet, Chief, Operations Branch Division of Reactor Safety ATTACHMENTS:

Attachment 1:

Supplemental Information i

Attachment 2:

' Simulation Facility Report

-

i I

i i

9706100194 970606 PDR ADOCK 05000445

PDR

,

.. -

--. - _ _

_ _ _

..

.

..

.

.

2-EXECUTIVE SUMMARY Comanche Peak Steam Electric Station, Units 1 and 2 NRC Inspection Report 50-445/97-06, 50-446/97-06 This inspection assessed the licensed operator requalification program to determine whether the program incorporated appropriate requirements for evaluating operators'

mastery of training objectives in accordance with 10 CFR 55.59(c). The assessment included an evaluation of the program's controls to assure a systems approach to training and evaluation of operating crew performance during annual requaiification examinations.

This included review of the facility documents, observation of operating and staff crews during dynamic simulator scenarios and plant walkthroughs, and an assessment of the cxamination evaluators' effectiveness in conducting and evaluating examinations. The inspection a!so included an evaluation of the plant referenced dynamic simulator used to conduct the examinations and the reference documentation used to produce the examinations and some control room observations.

Ooerations The control room operators exhibited professional demeanor and the shift turnover

briefings observed were effectivo and comprehensive (Section 01).

Overall, the licensed operator requalification training program effectively

implemented a systems approach to training and maintained the condition of licenses. However, the inspectors identified one procedural violation for a failure to ensure that appropriate glasses for use with self-contained breathing apparatus were available for licensed operators (Sections 04.1,05.1.,05.2,05.3,05.4, 05.5).

Licensed operators displayed good communication skills, teamwork, plant system

knowledge, and ownership of plant equipment (Sections 01.1, O4.1, F8.1).

Annual requalification examinations were comprehensive and discriminated at the

appropriate level (Section 05.1).

The licensed operator requalification f acility evaluators administered the

examinations professionally and in accordance with accepted industry practices (Section 05.2).

The licensee's training department was responsive to feedback and revised the

training program as appropriate (Section 05.3).

The licensee's process for operator remedial traimng was comprehensive in practice,

but did not provide specific, quantitative guidance for retest requirements (Section 05.4).

!

.

-

-3-

.

Plant Suonort Plant housekeeping was good (Section F8.1).

l

.

d i

$

4 l

.

-4-

'

Reoort Details

'

l. Operations

r

Conduct of Operations 01.1 Observations of Operator Performance a.

Inspection Scoce (71715)

Using the guidance of Inspection Procedure 71715, " Sustained Control Room and Plant Observation," the inspectcrs observed activities in the control room during norrnal plant operations. The inspectors compared the observed performance with expected performance as described in facility policies and procedures. The inspector observed two crew turnovers at power operations.

l b.

Observations and Findinas i

The inspector noted that the individual operator turnover briefings were thorough l

and detailed, and that both the oncoming and offgoing operators were alert and i

diligent in providing a professional turnover. Post-relief crew briefs were thorough and comprehensive with each member of the crew providing a status of activities

'

and equipment for their areas.

l l

The inspector observed consistently good and effective communications in accordance with management expectations. Operator communications were clear and unambiguous, and communication support equipment appeared reliable and adequate. Communications outside the control room were generally formal and consistently effective.

'

Control room conduct was formal. The shift nianager was closely involved in shift operations. Access to the control room was formally controlled and noise levels were maintained low and non-distracting to the control board operators. The licensed unit shift supervisors maintained a professional environment in the control room.

Operators routinely exhibited good self and peer checking when manipulating i

controls. The inspector observed that the operators performed peer checks on the

!

designated components,

-

j c.

Conclusions Operators exhibited good communication, annunciator response, procedure usage, t

self checking, and peer checking. Unit supervisors demonstrated effective oversight

)

of shift priorities.

l I

I

.

.

--5-

Operator Knowledge and Performance i

,,

!

04.1 Operator Performance on Annual Reaualification Examinations f

a.

Insoection Scope (71001)

!,

The inspectors observed the performance of two shift crews and one staff crew, during their annual requalification evaluations. Each crew was composed of five active licensed operators and one shift technical engineer. This Licensed Operator j

l Biennial 1995-1997 Requalification Cycle number 961 began on May 15,1995,

and ended on May 2,1997. The cycle consisted of an annual operating

)

examir ation, that included simulator dynamic performance evaluations and five job performance measures for each licensed operator. Also included was a written i

examination for each operator, consisting of a simulator static examination and an additional classroom examination.

l b.

Observations and Findinas With the exception of four licensed operator individual written examination failures, l

during the 2-year cycle,.all crews passed all portions of their biennial evaluations. In the 1995 biennial evaluation one senior reactor operator and one reactor operator j

failed their written exams. The licensee management reviewed these failures and previous performance and terminated both licenses. During the 1997 biennial I

evaluations, one senior reactor operator and one reactor operator again failed their

!

written exems. After licensee management review, these operators were successfulb/ remediated and returned to shift duties. The causes for the written

,

evaluation failures were primarily system knowledge deficiencies.

t i

On April 29 through May 2,1997, the inspectors observed the dynamic simulator, i

job performance measures, and written evaluations for the three crews. All crews l

and individuals passed their evaluations with the exception of the two written i

examination failures.

!

l l

Operator performance in the simulator was consistent with that observed in the

'

!

control room. The inspectors observed that formal communication practices were

)

I maintained even during stressful simulator scenario conditions.

c.

. Conclusions i

The inspectors concluded that the licensed operators exhibited good knowledge and

,

ability during the requalification examinations and that they maintained formal

!

communication practices even during stressful simulator scenario conditions.

i.

l

i I

I

_ -

.

.

-.

_

.

.

_ _. _.

__

-

_. _. _

-

i

~

i (

-6-

,

l

.

Operator Training and Qualification 05.1 Review of Reaualification Examinations a.

Inspection Scoce (71001)

The inspectors reviewed the annual requalification operating tests and biennial written examinations, to evaluate general quality, construction, and difficulty level.

-

The inspectors also reviewed the methodology for developing the requalification examinations.

.

b.

Observations and Findinas The operating examinations consisted of job performance measures and dynamic simulator scenarios.

The facility utilized the Westinghouse Owner's Group template evaluation scenarios as guidance in the development of the scenarios used for the requalification

examinations. The scenarios followed the guidelines of NUREG-1021, " Operator i

Licensing Examiner Standards," Revision 7, Supplement 1, in complexity and

{

quantitative event requirements. The scenarios were written with clear objectives, J

expected operator actions, and critical task identification and evaluation criteria.

The job performance measures were adequate in scope and depth, and covered a broad range of topics as required by the training program and the regulations.

Generally, critical steps were appropriately identified.

The inspectors determined that the written examinations were of the appropria;e breadth of cuverage and depth of knowledge, and effective discriminating value.

Repetition between consecutive examinations and quizzes was carefully limited to no more than 25 percent and each question's history was carefully tracked. The inspectors found that the licensee's implementing training procedures adequateiv provided guidance to assure that the 25 percent criteria war maintained for routine examinations.

c.

Conclusions The examinations were well constructed, challenging, and discriminated at the appropriate level.

I

~.

~.

-.

. - ~.

.

.

.

'

.

t

~7-05.2 Examination Adrninistration a.

Insoection Scone (71001)

The inspectors observed the administration of all aspects of the requalification examinations to determine the evaluators' abilities to administer an examination and assess adequate performance through measurable criteria. The inspectors also noted the fidelity of the plant simulator to support training and examination administration. The inspectors observed two operations shift crews and one staff crew of five licensed operators each, during conduct of the dynamic simulator scenarios and job performance measure evaluations. Four licensed operator requalification training evaluators and one operations management evaluator were observed participating in one or more aspects of administering the examinations, including pre-examination briefings, observations of operator performance, individual and group evaluations of observations, techniques for job performance measure cuing, and final evaluation documentation.

b.

Observations and Findinas

The evaluators conducted the examinations professionally, and thoroughly documented observations for later evaluation. Job performance measure cues were provided appropriately as needed, with no inadvertent cuing observed.

A formal method of evaluation was used that reviewed crew and individual critical

)

tasks following the scenario observations, and then competencies for the crew and

for individuals when appropriate. During the simulator evaluations, the inspectors

'

noted that the evaluator staff was particularly effective in identifying and properly categorizing operator performance deficiencies and weaknesses. The inspectors also observed strong operations staff participation. The post-scenario examination evaluation caucuses were well organized and efficient, with the evaluation team reaching a crisp, accurate consensus on performance results in a timely manner.

This minimized overall crew stress. The inspectors observed that the crews held j

i independent self-critical caucuses, led by their shift supervisors, who were also involved with developing remediation plans, when necessary. The inspectors also observed that shift supervisor ownership for crew and individual performance was a management expectation and was apparent in most cases.

!

The inspectors noted that the performance of the simulator in supporting the examination process was good. The inspectors did not identify any simulator j

fidelity performance problems that affected observed activities (see Attachment 2).

The inspectors reviewed the adequacy of the licensee's requalification program implementing procedures and instructions. The inspectors determined that the implementing procedures and instructions provided adequate guidance. However, the inspectors discussed some observations with the licensee's staff that may improve the procedures. as follows:

i l

l

.

. -

. _ _ _ _ _ __

. _. _ _ -... _ _ _. _,. _... _. _ _..

.

. _. _. _. _.

'

j

.

!

- f:

l

.

't

,

l

.

i

,

.

s

!

, The implementing procedure lacked specific guidance to preclude excessive

!

written examination question reuse for all possible situations, such as

!

<

nonconsecutive week and remedial examinations.

I l

Although the shift manager was responsible for the overall shift supervision,

procedures or instructions did not provide guidance to ensure that the shift j

l manager received a comprehensive examination on skills necessary to

!

implement the emergency operating procedures.

'

I t

The inspectors observed the licensee staff implement a " performance

!

enhancement" process for operators performing adequately, but with l

identified weaknesses. However, the inspectors found that this program enhancement was not formalized in the implementing procedures.

There was no quantitative guidance given for the development of remedial

examinations, repeatability of remediation written examination questions, or l

retest content.

I

1

_The inspectors noted that the 1997 biennial written examination had as littio

as 10 percent senior reactor operator only questions. While adequate in this case, inspectors noted that there was no procedure or instruction provided to

'

ensure that the seven 10 CFR 55.43 senior reactor operator topics were

!

covered during examination development.

l t

' The licensee's staff acknowledged these observations.

I I

c.

Conclusions i

The facility evaluators administered the examinations professionally and in accordance with industry standards. The facility evaluators effectively identified deficiencies or weaknesses to feedback into the training program. There was strong operations management evolvement in the simulator evaluations. The licensee's program implementing procedures were adequate.

05.3 Review of Trainino Feedback System a.

Insoection Scoce (71001)

The inspectors reviewed the methods and effectiveness of the licensed operator requalification training program feedback system.

I

!

l-n l

i

'

i l

l

.

,

.

.

,

,

'

b.

Observations and Findinas During interviews, licensed operators and staff trainers described several methods for providing feedback on the licensed operator requalification training program.

Written requests could be made with either a training feedback form or request for training form. Also, the operator could make verbal training requests to the instructors or training department management. A management observation

'

program also supported a periodic independent assessment of the training program effectiveness. Operators expressed overall satisfaction with the responses to their training requests.

The inspector reviewed r.umerous lesson plans and noted incorporation of recent industry events and lessons learned from plant events. Student feedback comments and management observations were positive and constructive, and each comment was classified and dispositioned in a formal program tracked by the training staff.

c.

Conclusions Operations personnel utilized several diverse methods for providing feedback to the j

licensed operator requalification training program. The training department i

responded appropriately to the training feedback provided.

05.4 Review of Remedial Trainina Proaram a.

Insoection Scope (71001)

The inspectors reviewed the remedial training program to evaluate comp!iance with licensee program guidance contained in Procedure TRA-2C?, " Licensed Operator Requalification Training," and to determine the effectiveness of the program to identify completed corrective actions. The inspectors reviewed five operator remedial training packages to determine whether adequate retraining and evaluation was performed based on the deficiencies identified.

b.

Observations and Findinas The inspectors noted that remediation was required when specific criteria in Procedure TRA-204 were not met. In all cases reviewed, inspectors found remedial training was conducted when appropriate to the displayed weakness or deficiency and as required by the procedure. When an operator was remediated for a written exarnination failure, he was required to review applicable lesson plans, discuss the system or operation with an instructor or other system expert, and finally be retested. Similar activities were required for walkthrough or dynamic scenario failure ___

.

,

-10-The inspectors reviewed the content of the one remedial written retest available from the 1995 and 1997 training cycles. Two retests planned were not available for review during the inspection since the failures occurred during the week of inspection.

c.

Conclusions The licensee's process for operator remedial training and retesting was comprehensive in practice.

05.5 Review of Conformance with Operator License Conditions:

a.

Inspection Scope (71001'

The inspectors evaluated the adequacy of the requalification program's compliance i

with Subpart C, " Medical Requirements," and 10 CFR 55.53, " License conditions."

The inspectors interviewed operators and training management, and examined the licensee's records to determine compliance for conditions to maintain an active operator license, reactivation of licenses, and medical fitness.

'

b.

Observations and Findinas Operator license conditions were being accurately identified and tracked. License conditions were complied within the sample selected. The inspectors found that the

'

licensee efficiently tracked operator licensed conditions and medical requirements with its computer based, " Operator Qualifications Program."

However, on April 28,1997, the inspectors found that no instructions or procedures existed at the Comanche Peak Steam Electric Station to ensure that all licensed operators that had their licenses conditioned to wear corrective lenses for the eye, had available appropriate lenses qualified for a self-contained breathing apparatus. The inspectors confirmed that the licensee had Final Safety Analysis Report, training, and administrative procedures that required all of their operators to be qualified in the use of self-contained breathing apparatus, and that self-contained breathing apparatus was staged as required in the control room.

However, the inspectors found that the licensee had not recognized the interaction

of these requirements and, as a result, did not have procedures or instructions in i

l place to ensure that speciallenses, qualified for s3lf-contained breathing apparatus

!

use, were available for operators in the control rcom. The inspectors found l

that out of the 82 operators at the facility,50 were required to wear corrective l

lenses. Failure c astablish such procedures or Mstructions was a violation of 10 CFR Part 50, Appendix B, Criterion V (50-445;-446/9706-01).

i l

. _ _

_. _.

_. - _ _ _ _._..._._.

.

.-_____._.__._;

.'

[

I

)

f

'

c-1 1 -

'

i

- Licensee management acknowledged the violation and took immediate actions 'to

'

correct the situation and preclude. recurrence. Until necessary corrective lenses could be obtained and properly staged, the licensee developed a corrective action,

"ONE" form to identify which operators had the appropriate lenses or no license condition and would stay in the control room, in self contained breathing apparatus, and which operators, with the license condition but no special lenses, would

- evacuate the control room to perform duties that did not require self-contained breathing apparatus. The inspectors observed that, in addition to these contingency actions, the licensee developed instructions to track adequate self-contained breathing apparatus qualified lenses for all operators that needed them to preclude a similar recurrence. The inspectors determined that these contingency actions and corrective measures were adequate.

c.

Conclusions The inspectors concluded that with the exception of providing corrective lenses for all conditions, the licensee accurately tracked, maintained, and controlled the conditions of operator licenses and reactivation of inactive licenses in accordance with Subpart C, " Medical Requirements," and 10 CFR 55.53, " License Conditions."

IV. Plant Support

,

F8 Miscellaneous Fire Protection issues

-

' *

F8.1 - General Comments The inspectors observed general plant housekeeping incident to administration of the iruplant job performance section of the operating test. The facility was reasonably clean, welllighted, and the floors were clear and free from debris. The I

operators were conscientious to note discrepancies and inform the main control room.

i

,

J

'

V. Manaaement Meetinos

X1 Exit Meeting Summary I

The examiners presented the inspection results to members of the licensee management at the conclusion of the inspection on May 2,1997. The licensee acknowledged the findings presented.

The inspectors expressed appreciation for the licensee's support and hospitality i

given to the visiting inspector from the Canadian Atomic Energy Control Board.

-

The licensee did not identify as proprietary any information or materials examined j

during the inspection.

.

-

_

-

_

-..

_

_

.

-

-

__. _. _

,

.

i ATTACHMENT 1

'

SUPPLEMENTAL INFORMATION

'

PARTIAL LIST OF PERSONS CONTACTED Licensee M. Blevins, Plant Manager S. Falley, Supervisor, Nuclear Training D. Goslwin, Operations Support Manager B. Guldemund, Shift Operations Manager J. Jank, Supervisor, Nuclear Training M. Sunseri, Manager, Nuclear Training L. Terry, Vice President, Nuclear Production Other

>

Ted Windle, Canadian Atomic Energy Control Board DOCUMENTS REVIEWED NRC PROCEDURES USED Inspection Procedure 71001, Licensed Operator Requalification Program Evaluation Inspection Procedure 71715, Sustained Control Room and Plant Observations i

licensee Procedures Reviewed I

Final Safety Analysis Report, Comanche Peak Steam Electric Station TRA-204, Licensed Operator Requalification Training Procedure, Revision 9 NTP-210, Nuclear Training Procedures Manual NTP-102, Analysis NTP-103, Design NTP-104, Development

'

NTP-402, Training Requests NTP-603, Simulator Certification Management NTP-601, Senior Reactor Operator Certification, Revision 6 NTP-201, Training impact System, Revision 6 NTP-105, implementation, Revision 9 NTP-106, Evaluation, Revision 5 LORT cycle 96-5 through 97-6 feedback comments and training response TRA-600, instructor Training, Revision 3 Corrective Action, ONE Form, W. G. Guldemund, dated May 1,1997 Nuclear Overview Department Evaluation Report, NOE-EVAL-97-000054

{

l

.

..

_

..

.

,

.

.

-

-

.__ ~

.

.

,

ATTACHMENT 2 SIMULATION FACILITY REPORT Facility Licensee: Comanche Peak Steam Electric Station, Units 1 and 2 Facility Docket: 50-445,50-446 Operating Examinations Administered at: Comanche Peak Steam Electric Station, Units 1 and 2, FM-56, Glen Rose, Tx.

Operating Examinations Administered on: Week of April 28,1997 The inspectors did not identify any simulator fidelity performance problems that affected observed activities.

.

l