Text
rch 11, 2004
SUBJECT:
SAN ONOFRE NUCLEAR GENERATING STATION - NRC RADIATION SAFETY TEAM INSPECTION REPORT 05000361/2004006; 05000362/2004006
Dear Mr. Ray:
On January 30, 2004, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at your San Onofre Nuclear Generating Station, Units 2 and 3, facility. The enclosed Radiation Safety Team inspection report documents the inspection findings, which were discussed at the conclusion of the inspection with Messrs. J. Wambold and D. Nunn, and other members of your staff.
The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.
The team reviewed selected procedures and records, observed activities, and interviewed personnel. Specifically, the team evaluated the inspectible areas within the Radiation Protection Strategic Performance Area that are scheduled for review every two years. These areas are:
- Radiation Monitoring Instrumentation
- Radioactive Gaseous and Liquid Effluent Treatment and Monitoring Systems
- Radioactive Material Processing and Transportation
- Radiological Environmental Monitoring Program and Radioactive Material Control Program This inspection report documents two self-revealing findings of very low safety significance (Green). However, because of the very low safety significance and because the findings were entered into your corrective action program, the NRC is treating these findings as noncited violations (NCVs) consistent with Section V1.A of the NRC Enforcement Policy. Additionally, one licensee-identified violation was determined to be of very low safety significance and is listed in Section 4OA7 in this report. If you contest the violations or significance of these NCVs, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, DC 20555-0001, with copies to the Regional Administrator, U.S.
Nuclear Regulatory Commission, Region IV, 611 Ryan Plaza Drive, Suite 400, Arlington, Texas 76011; the Director, Office of Enforcement, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001; and the NRC Resident Inspector at the San Onofre Station facility.
Southern California Edison Co. -2-In accordance with 10 CFR 2.390 of the NRCs "Rules of Practice," a copy of this letter, its enclosure, and your response (if any) will be made available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely,
//RA//
Troy W. Pruett, Chief Plant Support Branch Division of Reactor Safety Dockets: 50-361 50-362 Licenses: NPF-10 NPF-15 Enclosure:
NRC Inspection Report 05000361/2004006; 05000362/2004006 cc w/enclosure:
Chairman, Board of Supervisors County of San Diego 1600 Pacific Highway, Room 335 San Diego, CA 92101 Gary L. Nolff Power Projects/Contracts Manager Riverside Public Utilities 2911 Adams Street Riverside, CA 92504 Eileen M. Teichert, Esq.
Supervising Deputy City Attorney City of Riverside 3900 Main Street Riverside, CA 92522 Joseph J. Wambold, Vice President Southern California Edison Company San Onofre Nuclear Generating Station P.O. Box 128 San Clemente, CA 92674-0128
Southern California Edison Co. -3-David Spath, Chief Division of Drinking Water and Environmental Management California Department of Health Services P.O. Box 942732 Sacramento, CA 94234-7320 Michael R. Olson San Onofre Liaison San Diego Gas & Electric Company P.O. Box 1831 San Diego, CA 92112-4150 Ed Bailey, Radiation Control Program Director Radiologic Health Branch California Department of Health Services P.O. Box 942732 (MS 178)
Sacramento, CA 94234-7320 Mayor City of San Clemente 100 Avenida Presidio San Clemente, CA 92672 James D. Boyd, Commissioner California Energy Commission 1516 Ninth Street (MS 34)
Sacramento, CA 95814 Douglas K. Porter, Esq.
Southern California Edison Company 2244 Walnut Grove Avenue Rosemead, CA 91770 Dwight E. Nunn, Vice President Southern California Edison Company San Onofre Nuclear Generating Station P.O. Box 128 San Clemente, CA 92674-0128 D
SUMMARY OF FINDINGS
San Onofre Nuclear Generating Station, Units 2 & 3
NRC Inspection Report 05000361/04-06; 05000362/04-06 Inspection Dates: January 26 through 30, 2004 IR 05000361/2004-06, 05000362/2004-06; 01/26 -30/2004; San Onofre Nuclear Generating Station, Units 2 and 3; Radioactive Material Control Program; Radioactive Gaseous and Liquid Effluent Treatment and Monitoring Systems The report covered a one week period of inspection on site by a team of four region-based health physics inspectors. Two findings of very low safety significance (Green) were identified.
The significance of most findings is indicated by their color (Green, White, Yellow, Red) using IMC 0609, Significance Determination Process, (SDP). Findings for which the SDP does not apply may be Green or be assigned a severity level after NRC management review. The NRC's program for overseeing the safe operation of commercial nuclear power reactors is described in NUREG-1649, Reactor Oversight Process, Revision 3, dated July 2000.
NRC-Identified and Self-Revealing Findings
Cornerstone: Public Radiation Safety
C
- Green.
A self-revealing, non-cited violation of Technical Specification 5.5.2.1 was reviewed by the team because the licensee failed to have all the required effluent monitors channels operable or implement auxiliary sampling requirements as specified in the Offsite Dose Calculation Manual. Specifically, the Unit 3 condenser air ejector monitor (3-7870) was declared inoperable on May 26, 2003, at 5:40 p.m. and auxiliary sampling equipment was initially put in place. However, from 8:00 p.m. on May 27, 2003, until 9:55 a.m. on May 28, 2003, continuous particulate and iodine samples were not obtained via the compensatory sampling device because a chemistry technician did not install the necessary filters. The situation was discovered during the successive, routine filter change out.
The finding was greater than minor because it was associated with cornerstone attributes (radiation monitoring and chemistry technician performance) and affected the associated cornerstone objective (to ensure adequate protection of public health and safety from exposure to radioactive materials released into the public domain). The finding involved an occurrence in the licensee's radiological effluent monitoring program that was contrary to Offsite Dose Calculation Manual requirements; therefore, it was evaluated using the Public Radiation Safety Significance Determination Process. The finding had very low significance because the finding was not a radioactive material control finding, but it was an effluent release program finding. The finding impaired the licensees ability to assess dose; however, the licensee was able to assess dose to the public through use of an operational noble gas monitor (3RT-7818) in the condenser evacuation system and the dose did not exceed 10 CFR Part 50 Appendix I values (Section 2PS1).
C
- Green.
A self-revealing, non-cited violation of Technical Specification 5.5.1 was reviewed by the team because the licensee failed to follow radiation protection procedures related to the release of radioactive material from the protected area.
Specifically, on November 6, 2003, the licensee discovered one magenta-painted hose in a 55-gallon drum which had been stored in the Mesa area (outside the protected area) since January 1998. The licensee surveyed the hose and determined that it contained a total fixed activity of 40 nanocuries.
The finding was greater than minor because it is associated with the cornerstone attribute (material release) and it affected the associated cornerstone objective (to ensure adequate protection of public health and safety from exposure to radioactive material released into the public domain). The finding involved an occurrence in the licensees radioactive material control program that was contrary to licensee procedures.
This finding was evaluated as having very low safety significance using the Public Radiation Safety Significance Determination Process because the finding was a radioactive material control issue, was not a transportation issue, public exposure was not greater than 5 millirem, and there were less than 5 occurrences over the past rolling quarters (Section 2PS3).
B. Licensee Identified Violation A violation of very low safety significance (Green) which was identified by the licensee was reviewed by the team. Corrective actions taken or planned by the licensee have been entered into the licensees corrective action program. This violation and corrective action tracking number is listed in Section 4OA7.
REPORT DETAILS
RADIATION SAFETY
Cornerstones: Occupational Radiation Safety [OS] and Public Radiation Safety [PS] 2OS3 Radiation Monitoring Instrumentation and Protective Equipment (71121.03)
a. Inspection Scope
This area was inspected to determine the accuracy and operability of radiation monitoring instruments that are used for the protection of occupational workers and the adequacy of the program to provide self-contained breathing apparatus (SCBA) to workers. The team used the requirements in 10 CFR Part 20 and the licensees procedures required by technical specifications as criteria for determining compliance.
The team interviewed licensee personnel and reviewed:
- Calibration data for 6 area radiation monitors associated with transient high and very high radiation areas and 12 post-accident monitors used for remote emergency assessment
- Calibration data for 4 portable radiation detection instrumentation, 10 electronic alarming dosimeters, and one continuous air monitor
- Calibration data for 2 whole body counters located at the 70 foot access facility, 6 radiation detection instruments, and 9 personnel monitors utilized for material release from the radiologically controlled area
- Audit records (No LERs or self-assessments were submitted during the inspection period)
- Eighteen corrective action program reports since the last inspection
- Repetitive deficiencies or significant individual deficiencies which occurred during the inspection period (No repetitive or significant individual deficiencies occurred)
- Calibration expiration and source response check currency on 4 radiation detection instruments staged for use
- The licensees capability for refilling and transporting SCBA air bottles to and from the control room and operations support center during emergency conditions, status of SCBA staged and ready for use in the plant and associated surveillance records, and personnel qualification and training
- Qualification documentation for onsite personnel designated to perform maintenance on the vendor-designated vital components, and the vital component maintenance records for SCBA units The inspector completed 9 of the required 9 samples.
b. Findings
No findings of significance were identified.
2PS1 Radioactive Gaseous and Liquid Effluent Treatment and Monitoring Systems (71122.01)
a. Inspection Scope
This area was inspected to ensure that the gaseous and liquid effluent processing systems are maintained so that radiological releases are properly mitigated, monitored, and evaluated with respect to public exposure. The team used the requirements in 10 CFR Part 20, 10 CFR Part 50 Appendices A and I, the Offsite Dose Calculation Manual (ODCM), and the licensees procedures required by technical specifications as criteria for determining compliance. The team interviewed licensee personnel and reviewed:
- Self assessments, audits, and the most current radiological effluent release reports (No changes to radiation monitor setpoint calculation methodology, anomalous sampling results, or effluent radiological occurrence performance indicator incidents occurred during the inspection period)
- All gaseous and liquid release system component configurations
- Routine sample collection and analysis of radioactive gaseous effluent, two radioactive liquid and gaseous effluent release permits, and associated dose projections to members of the public
- Abnormal releases (None were identified)
- Significant changes made by the licensee to the ODCM, the liquid or gaseous radioactive waste system design, procedures, or plant operation which occurred during the inspection period (No significant changes were identified)
- Monthly, quarterly, and annual dose calculations included in the effluent release reports
- Three surveillance test results involving air cleaning systems and associated vent flow rates
- Instrument calibration data for five discharge effluent radiation monitors and flow measurement devices, associated effluent radiation monitor alarm setpoint values, and daily counting room instrumentation calibration and quality control checks (No effluent monitoring system modifications occurred during the inspection period)
- Interlaboratory comparison program results
- Audit reports, self-assessments, and 12 corrective action reports performed during the inspection period (No LERs or special reports occurred during the inspection period)
The inspector completed 10 of the required 10 samples.
b. Findings
Introduction.
A Green self-revealing, non-cited violation of the Technical Specification 5.5.2.1 was reviewed by the team. The licensee failed to have all the required effluent monitor channels operable or implement auxiliary sampling equipment as required by the ODCM.
Description.
The Unit 3 condenser air ejector monitor (3-7870) was declared inoperable on May 26, 2003, at 5:40 p.m. Auxiliary sampling equipment was put in place.
However, from 8:00 p.m. on May 27, 2003, until 9:55 a.m. on May 28, 2003, continuous particulate and iodine samples were not obtained via the compensatory sampling device because a chemistry technician did not install the necessary filters. The situation was discovered during the successive, routine filter change out.
Analysis.
The failure to have an operable monitor or implement auxiliary compensatory actions was a performance deficiency. The finding was greater than minor because it was associated with cornerstone attributes (radiation monitoring and chemistry technician performance) and affected the associated cornerstone objective (to ensure adequate protection of public health and safety from exposure to radioactive materials released into the public domain). The finding involved an occurrence in the licensee's radiological effluent monitoring program that was contrary to ODCM requirements, therefore it was evaluated using the Public Radiation Safety Significance Determination Process.
The finding had very low significance because the finding was not a radioactive material control finding, but it was an effluent release program finding. The finding impaired the licensees ability to assess dose; however, the licensee was able to assess dose to the public through use of an operational noble gas monitor (3RT-7818) in the condenser evacuation system and the dose did not exceed 10 CFR Part 50 Appendix I values.
Enforcement.
Technical Specification 5.5.2.1 requires that the ODCM shall be established, implemented, and maintained. ODCM Section 4.2.1 requires the radioactive gaseous effluent monitoring instrumentation channels shown in Table 4-3 to be operable.
Table 4-3, Sections 2b and 2c, include channels for an iodine sampler and a particulate sampler, respectively. Action 40, states, in part, that with the number of channels operable less than required by the Minimum Channel Operable requirement, effluent releases via the effected pathway may continue, provided samples are continuously collected with auxiliary sampling equipment. The licensee violated this requirement when filters were not installed in the auxiliary sampling equipment. However, because the failure to have an operable effluent monitor and auxiliary sampling was of very low safety significance and has been entered into the stations corrective action program as Action Request 030600245, this violation is being treated as a non-cited violation, consistent with Section VI.A of the NRC Enforcement Policy: NCV 050-362/0406-01, Failure to have all the required effluent monitor channels operable or implement auxiliary sampling equipment.
2PS2 Radioactive Material Processing and Transportation (71122.02)
a. Inspection Scope
This area was inspected to verify that the licensees radioactive material processing and transportation program complies with the requirements of 10 CFR Parts 20, 61, and 71 and Department of Transportation regulations contained in 49 CFR Parts 170-189. The team interviewed licensee personnel and reviewed:
- The final safety analysis report radioactive waste system description, recent radiological effluent release reports, and the scope of the licensees audit program
- Liquid and solid radioactive waste processing systems configurations, the status and control of all radioactive waste process equipment that is not operational or is abandoned in place, changes made to the radioactive waste processing systems since the last inspection (No changes were identified during the inspection period), and current processes for transferring radioactive waste resin and sludge discharges
- 2001 and 2002 radio-chemical sample analysis results for radioactive waste streams and use of scaling factors and calculations to account for difficult-to-measure radionuclides
- Shipment packaging, surveying, labeling, marking, placarding, vehicle checking, driver instructing, and disposal manifesting (No shipments were performed during the on-site inspection)
- Shipping records for six non-excepted package shipments and licenses
- Audits, self-assessments, and eight corrective action reports performed since the last inspection (No LERs or special reports occurred during the inspection period)
The inspector completed 5 of the required 6 samples. The inspector was unable to observe the preparation and shipment of radioactive material because no shipments were conducted during the on-site inspection period.
b. Findings
No findings of significance were identified.
2PS3 Radiological Environmental Monitoring Program and Radioactive Material Control Program (71122.03)
a. Inspection Scope
This area was inspected to ensure that the Radiological Environmental Monitoring Program (REMP) verifies the impact of radioactive effluent releases to the environment and sufficiently validates the integrity of the radioactive gaseous and liquid effluent release program; and that the licensees surveys and controls are adequate to prevent the inadvertent release of licensed materials into the public domain. The team used the requirements in 10 CFR Part 20, 10 CFR Part 50, Appendix I, the ODCM, and the licensees procedures required by technical specifications as criteria for determining compliance. The team interviewed licensee personnel and reviewed:
- Annual environmental monitoring reports
- Nine air sampling stations and thermoluminescence dosimeter (TLD) monitoring stations
- Collection and preparation of environmental samples (None were performed during the on-site inspection)
- Operability, calibration, and maintenance records of all meteorological instruments
- Events documented in the Annual Environmental Monitoring Report which involved a missed sample, inoperable sampler, lost TLD, or anomalous measurement (No examples were identified)
- Significant changes made by the licensee to the ODCM as the result of changes to the land census or sampler station modifications since the last inspection (No significant changes were identified)
- Calibration and maintenance records for ten air samplers, composite water samplers, and radiation measurement instrumentation, quality control program, interlaboratory comparison program results, and vendor audits (The licensee did not have composite water samplers)
- All locations where the licensee monitors potentially contaminated material leaving the radiologically controlled area and the methods used for control, survey, and release from these areas
- Radiation monitoring instrumentation used to monitor items released, survey and release criteria of potentially contaminated material, radiation detection sensitivities, procedural guidance, and material release records
- Six audits, 5 self-assessments, and 19 corrective action reports performed since the last inspection (No licensee event reports or special reports were submitted during the inspection period.)
The inspector completed 9 of the required 10 samples. The inspector was unable to observe the collection and preparation of environmental samples because no samples were collected during the on-site inspection period.
b. Findings
Introduction.
A Green self-revealing, non-cited violation was reviewed for the failure to follow radiation protection procedures as required by Technical Specification 5.5.1.
related to the release or radioactive material from the protected area.
Description.
The team determined that on November 6, 2003, the licensee discovered one magenta-painted hose in a 55-gallon drum which had been stored in the Mesa area (outside the protected) since January 1998. The licensee surveyed the hose and determined that it contained a total fixed activity of 40 nanocuries. In 1998 the hose had been used to replace charcoal in the Units 2/3 Fuel Handling Building Post Accident Cleanup Units. Four 55-gallon drums containing equipment related to this job were released to the Mesa for storage on January 15, 1998. The failure to identify the contaminated hose, and the release of radioactive material from the protected area, is a violation of Technical Specifications.
Analysis.
The team determined that release of a radioactive material from the licensees protected area is a performance deficiency. The finding was greater than minor because it is associated with the cornerstone objective (material release) and it affected the associated cornerstone objective (to ensure adequate protection of public health and safety from exposure to radioactive material released into the public domain).
The finding was associated with a violation of NRC requirements. This finding was evaluated as having very low safety significance using the Public Radiation Safety Significance Determination Process because the finding was a radioactive material control issue, was not a transportation issue, public exposure was not greater than 5 millirem, and there were less than 5 occurrences over the past rolling 8 quarters.
Enforcement.
Technical Specification 5.5.1 requires that written procedures shall be established and implemented covering those procedures recommended in Regulatory Guide (RG) 1.33, Appendix A, for the control of radioactivity and limiting personnel exposure. Procedure SO123-VII-20.9.2, Material Release Surveys, Revision 4, Section 6.1.1, required a release criterion of no detectable licensed activity above background. However, the licensee failed to identify and prevent the release of radioactive material from the protected area. Because this failure is of very low safety significance and has been entered into the licensees corrective action system as Action Request 031100334, this violation is being treated as an NCV, consistent with Section VI.A of the NRC Enforcement Policy: NCV 05000361/0406-02; 05000362/0406-02, Release of a Contaminated Hose from the Protected Area.
OTHER ACTIVITIES
4OA2 Problem Identification and Resolution
Annual Sample Review
a. Inspection Scope
The team evaluated the effectiveness of the licensees problem identification and resolution process with respect to the following inspection areas:
- Radiation Monitoring Instrumentation (Section 2OS3)
- Radioactive Gaseous and Liquid Effluent Treatment and Monitoring Systems (Section 2PS1)
- Radioactive Material Processing and Transportation (Section 2PS2)
- Radiological Environmental Monitoring Program and Radioactive Material Control Program (Section 2PS3)
b. Findings and Observations
No findings of significance were identified.
4OA6 Management Meetings
Exit Meeting Summary
On January 30, 2004, the team presented the inspection results to Messrs. J. Wambold and D. Nunn, and other members of your staff who acknowledged the findings. One proprietary document was reviewed by the team during the inspection but was not copied or retained.
On February 19, 2004, the team telephonically presented the final inspection results to Mr. M. McBrearty who acknowledged the findings.
4OA7 Licensee-Identified Violations
The following finding of very low safety significance was identified by the licensee as a violation of NRC requirements which meet the criteria of Section VI of the NRC Enforcement Policy, NUREG-1600, for being dispositioned as NCV.
- 10 CFR Part 20.2006(d) states in part, that each licensee involved in the disposal of waste, shall comply with the requirements specified in Section III of Appendix G to 10 CFR Part 20. 10 CFR Part 20 Appendix G, Section III, E, requires, in part, that any shipment for which acknowledgment is not received within 20 days after transfer be investigated by the shipper, and be traced and reported to the NRC within two weeks of completion of the investigation. In May 2003 during a QA audit the licensee identified 28 shipments of radioactive waste that had not been acknowledged by the burial ground within 20 days after transfer. The late shipments were not investigated, traced or reported to the NRC. The finding was determined to be of very low safety significance because radiation limits were not exceeded, there was no breach of package during transit, there was no Certificate of Compliance finding, the finding was not a low level burial ground nonconformance, and the finding was not a failure to make notifications or provide emergency information.
ATTACHMENT
SUPPLEMENTAL INFORMATION
KEY POINTS OF CONTACT
Licensee personnel
- J. Chang, Engineer, Maintenance
- D. Dick, Effluent Supervisor, Chemistry
- P. Elliott, Supervisor, Health Physics
- M. Farmer, Supervisor, Health Physics
- A. Gray, Supervisor, Health Physics
- F. Liu, Engineer, Maintenance Engineering
- J. Madigan, Manager, Health Physics
- M. McBrearty, Engineer, Nuclear Regulatory Affairs
- D. McBride, Supervisor, Maintenance
- D. Nunn, Vice President, Engineering & Technical Services
- A. Scherer, Manager, Nuclear Regulatory Affairs
- S. Vaughan, Supervisor, Health Physics
- R. Waldo, Station Manager
- J. Wambold, Vice President, Nuclear Generation
NRC
- C. Osterholtz, Senior Resident Inspector
- M. Sitek, Resident Inspector
LIST OF ITEMS OPENED, CLOSED, AND DISCUSSED
Opened
NONE Opened and Closed During this Inspection
- 05000362/2004006-01 NCV Failure to have all the required effluent monitor channels operable or implement auxiliary sampling equipment.
- 05000361,362/2004006-02 NCV Release of a contaminated hose from the protected area.
Previous Items
Closed
NONE Previous Items
Discussed
NONE
-2-