- _ _ _ _ - _ - _ _ _ _ _ -

Florida Power Corporation Mr. W. S. Wilgus Vice President Nuclear Operations ATTN: Manager, Nuclear Licensing P. O. Box 219 Crystal River, FL 32629 Gentlemen:

SUBJECT:

NRC INSPECTION REPORT NO. 50-302/87-29 Thank you for your response of November 18, 1987, to our Notice of Violation, issued on October 22, 1987, concerning activities conducted at your Crystal River facility.

We have evaluated your response and found that it meets the requirements of 10 CFR 2.201.

We will examine the implementation of your corrective actions during future inspections.

We appreciate your cooperation in this matter.

Sincerely, ORIGINAL SIGNED BY DOUGLAS M. COLLINS Douglas M. Collins, Chief Emergency Preparedness and Radiological Protection Branch Division of Radiation Safety and Safeguards cc:

P. F. McKee, Director, Nuclear Plant Operations E. C. Simpson, Director, Nuclear Site Support bec: NRC Resident Inspector DRS Technical Assistant Document Control Desk State of Florida l

RII RII RII

,

y

' GKuzo C osey BWilsh" 12/i /87 12/j/87 12/3/87 i

8712110303 871203 PDR ADOCK 05000302 j

O PDR 3 E' cl

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _