Finding | |
|---|---|
| Title | Failure to Report a Condition that Could Have Prevented the
Fulfillment of a Safety Function |
| Description | The inspectors identified a noncited violation of 10 CFR 50.73(a)(2)(i)(B) and 10 CFR 50.73(a)(2)(v)(B) and after Pacific Gas and Electric failed to submit a required licensee event report within 60 days following discovery of a condition prohibited by the plant technical specifications and a condition that could have prevented the fulfillment of a safety function. On March 9, 2010, Pacific Gas and Electric identified that the degraded voltage protection scheme, required by Technical Specification 3.3.5, Loss of Power Diesel Generator Start Instrumentation, was inadequate to protect operating engineering safety feature pump motors. The licensee concluded that sustained degraded voltage could result in an overcurrent condition affecting equipment powered from the preferred offsite power supply. This condition was required to be reported to the NRC because the degraded voltage protection scheme rendered engineered safety feature pumps inoperable for a period in excess of the allowable technical specification out of service time and the condition resulted in the loss of the degraded voltage protection scheme safety function on all three vital 4 kV power buses. The inspectors evaluated this finding using the traditional enforcement process because the failure to submit a required event report affected the NRCs ability to perform its regulatory function. The inspectors concluded the violation was a Severity Level IV because the licensee failed to submit an adequate licensee event report. The inspectors determined that the violation was also a finding under the reactor oversight process because licensee personnel failed to adequately evaluate a condition adverse to quality for operability and reportability, as required by station procedures. The inspectors concluded that the finding is more than minor because the failure to properly evaluate degraded plant equipment for past operability and reportability could reasonably be seen to lead to a more significant condition. The inspectors concluded that the finding had very low safety significance because the failure to adequately evaluate the condition did not result in an actual loss of a system safety function or equipment required by technical specifications, or involve the loss or degradation of equipment specifically designed to mitigate a seismic, flooding, or sever
weather initiating event, and did not involve the total loss of any safety function that contributes to an external event initiated core damage accident sequence This finding has a crosscutting aspect in the area of problem identification and resolution, associated with the corrective action program component because the licensee failed to perform an adequate evaluation of the degraded voltage protection scheme such that the resolutions address causes and extent of conditions, as necessary. |
| Site: | Diablo Canyon |
|---|---|
| Report | IR 05000275/2010003 Section 4OA3 |
| Date counted | Jun 30, 2010 (2010Q2) |
| Type: | TEV: Severity level IV |
| cornerstone | No Cornerstone |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71153 |
| Inspectors (proximate) | L Ricketson M Brown M Peck C Graves D Stearns G Miller A Erickson |
| CCA | P.2, Evaluation |
| INPO aspect | PI.2 |
| ' | |