Finding | |
|---|---|
| Title | Nonconservative Inputs into Motor Operated Valve Calculation |
| Description | The team identified a noncited violation of 10 CFR Part 50, Appendix B, Criterion III, \"Design Control\" involving multiple mechanical and electrical errors in documentation associated with torque, thrust, and operation of certain safety related motor operated valves. Specifically, on March 3, 2010, the team identified seven different numerical inputs to the operation, margin, and functionality of certain safety related motor operated valves, which had nonconservative inputs for the mechanical and electrical settings of the motor operated valves. The composite of these nonconservative inputs could have a detrimental effect on the operation of these motor operated valves. Contrary to above, on March 3, 2010, per 10 CFR Part 50, Appendix B, Criterion III, \"Design Control\", the licensee did not establish measures to assure that applicable regulatory requirements and the design basis, for those structures, systems, and components were correctly translated into specifications, drawings, procedures, and instructions. The licensee has entered this issue into their corrective action process as Notification 50302437. The failure of the licensee to correctly translate design basis information into specifications, drawing, procedures, and instructions is a performance deficiency. Using Inspection Manual Chapter 0612, Appendix E, Section 3, Example j, the violation was determined to be more than minor because the engineering calculation error results in a condition where there is now a reasonable doubt on the operability of a system or component. Using the Inspection Manual Chapter 0609, \"Significance Determination Process,\" Phase 1 Worksheets, the finding was determined to have very low safety significance (Green) because it was not a design issue resulting in loss of function, did not represent an actual loss of a system safety function, did not result in exceeding a technical specification allowed outage time, and did not affect external event mitigation. The inspectors reviewed the finding for crosscutting aspects and none were identified. |
| Site: | Diablo Canyon |
|---|---|
| Report | IR 05000275/2010007 Section 1R21 |
| Date counted | Jun 30, 2010 (2010Q2) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Inspectors (proximate) | T Farnholtz S Makor B Correll S Hedger R Kbpriva |
| INPO aspect | |
| ' | |
Finding - Diablo Canyon - IR 05000275/2010007 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Diablo Canyon) @ 2010Q2
Self-Identified List (Diablo Canyon)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||