05000275/FIN-2010003-04
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Licensee-Identified Violation |
| Description | The following finding of very low safety significance (Green) was identified by the licensee and is a violation of NRC requirements which meets the criteria of the NRC Enforcement Policy, NUREG-1600, for being dispositioned as a noncited violation. Title 10 of the Code of Federal Regulations, Part 50, Appendix B, Criteria V, Instructions, Procedures, and Drawings, required that activities affecting quality shall be prescribed by procedures, and shall be accomplished in accordance with these procedures. Procedure TS6.ID2, Control and Accountability of Special Nuclear Material, Revision 21, Attachment 7.15, Spent Fuel Pool Decay Heat Loading Requirements, specified restrictions for placement of recently discharged spent fuel assemblies in the spent fuel pool. Contrary to this, on April 27, 2010, Pacific Gas and Electric identified five recently discharged fuel assemblies improperly located in the spent fuel pool. The licensee took corrective action to restore the spent fuel pool configuration consistent with procedural requirements. The inspectors used Inspection Manual Chapter 0609.04, Phase 1 - Initial Screening and Characterization of Findings, to analyze the finding. The inspectors concluded that the failure to accomplish an activity affecting quality in accordance with Procedure TS6.ID2, Attachment 7.15, was a Green finding of very low safety significance because the finding did not result in loss of cooling to the spent fuel pool, whereby operator or equipment failures could preclude restoration of cooling prior to boiling, did not result from fuel handling errors that caused damage to fuel clad integrity or a dropped assembly, and did not result in a loss of spent fuel pool inventory greater than 10 percent of the spent fuel pool volume. Pacific Gas and Electric entered the issue into the corrective action program as Notification 50314008 |
| Site: | Diablo Canyon |
|---|---|
| Report | IR 05000275/2010003 Section 4OA7 |
| Date counted | Jun 30, 2010 (2010Q2) |
| Type: | NCV: Green |
| cornerstone | No Cornerstone |
| Identified by: | Licensee-identified |
| Inspection Procedure: | |
| Inspectors (proximate) | L Ricketson M Brown M Peck C Graves D Stearns G Miller A Erickson |
| INPO aspect | |
| ' | |
Finding - Diablo Canyon - IR 05000275/2010003 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Diablo Canyon) @ 2010Q2
Self-Identified List (Diablo Canyon)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||