Finding | |
---|---|
Title | Failure to Correct a Condition Adverse to Quality Associated Cooling Water Flow Degradation in the 1B Core Spray Room Cooler |
Description | The inspectors identified a non-cited violation of 10 CFR 50, Appendix B, Criterion XVI, Corrective Action, for the licensees failure to correct a condition adverse to quality and implement adequate corrective actions for the degraded 1B Core Spray (CS) room cooler. The licensee failed to implement adequate correct actions to address the inability of the room cooler perform its design function with degraded cooling water flow prior to its loss of function on June 25, 2010. The licensee has since replaced the cooler in order to provide additional flow margin. The failure to take adequate corrective actions to address the potential high river temperature along with degraded heat exchanger flow was a performance deficiency. The performance deficiency was more than minor because it is associated with the Equipment Performance attribute of the Mitigating Systems Cornerstone and adversely affected the availability of the 1B CS room cooler to respond to initiating events. The inspectors determined that a Phase 2 screening was required because the 1B division of core spray was inoperable for greater than the 7 day technical specification allowed out of service time. Using the pre-solved Phase Two significance determination worksheet, the inspectors determined that the finding was of very low safety significance. The inspectors determined that this finding directly involved the cross-cutting area of Problem Identification and Resolution, component of the Corrective Action Program and aspect of Appropriate and Timely Corrective Actions because the licensee did not implement appropriate and timely corrective actions to resolve a condition adverse to quality. Specifically, the licensee failed to address the debris fouling of the 1B CS room cooler prior to its failure on June 25, 2010. |
Site: | Browns Ferry ![]() |
---|---|
Report | IR 05000259/2010006 Section 4OA2 |
Date counted | Sep 30, 2010 (2010Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | G Hopper A Sabisch P Higgins M Barillas |
CCA | P.3, Resolution |
INPO aspect | PI.3 |
' | |
Finding - Browns Ferry - IR 05000259/2010006 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Browns Ferry) @ 2010Q3
Self-Identified List (Browns Ferry)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||