05000259/FIN-2009008-04
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Licensee-Identified Violation |
Description | 10 CFR 50, Appendix B, Criterion III, Design Control, requires that that measures shall be established to assure that applicable regulatory requirements and the design basis for structures, systems, and components are correctly translated into specifications, drawings, procedures, and instructions. During a design basis loss of coolant accident (LOCA) on Unit 1 (2) concurrent with a LOOP on all three units, given a single active failure affecting a Unit 1/2 EDG or 4160V shutdown board, there could be insufficient power for two RHR pumps to provide suppression pool cooling on Unit 2 (1). Suppression pool cooling on the non-LOCA units will be required to maintain suppression pool temperature within acceptable limits during RCIC and/or HPCI operation during a LOOP. Contrary to this, the licensee had inadequate design basis documentation (calculations) to support parallel EDG operations. This was identified in the licensees corrective action program as PER 178142. The inspectors assessed the finding using the SDP and determined that the finding was of very low safety significance (Green) because of the low initiating event likelihood frequency of LOCA on one unit concurrent with a LOOP on all three units |
Site: | Browns Ferry ![]() |
---|---|
Report | IR 05000259/2009008 Section 4OA7 |
Date counted | Dec 31, 2009 (2009Q4) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | Licensee-identified |
Inspection Procedure: | |
Inspectors (proximate) | J Leivo R Aiello R Berryman H Campbell C Even R Patterson B Desai J Kent |
INPO aspect | |
' | |
Finding - Browns Ferry - IR 05000259/2009008 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Browns Ferry) @ 2009Q4
Self-Identified List (Browns Ferry)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||