Finding | |
|---|---|
| Title | Deficiencies with Emergency Lighting Units |
| Description | The team identified a Green non-cited violation of Browns Ferry Units 1, 2, and 3 Operating License Conditions 2.C(13), 2.C(14), and 2.C(7), respectively, for the licensees failure to maintain in effect all provisions of the NRC-approved fire protection program, as described in the Final Safety Analysis Report. The Fire Protection Report (referenced in the Final Safety Analysis Report) requires that measures be established to ensure that conditions adverse to fire protection, such as failures and deficiencies, are promptly identified and corrected. The licensee had not established measures to identify and correct an excessive number of Appendix R emergency lighting unit failures. Specifically, emergency lighting unit failures were not being entered in the corrective action program as problem evaluation reports in order to evaluate and resolve why many of the emergency lighting failures occurred prior to reaching their 6-year replacement date. Additionally, the Fire Protection Report surveillance requirement to replace the Appendix R emergency lighting unit batteries and lamp heads every six years was not being adequately implemented, in that licensee data revealed that several installed emergency lighting units were beyond their 6-year replacement date. The licensee entered this finding into their corrective action program and initiated corrective actions to address these issues. The licensees failure to meet the Fire Protection Report requirements to establish measures to identify and correct a condition adverse to fire protection (excessive Appendix R emergency lighting unit failures); and, to implement the Appendix R emergency lighting system replacement program, is a performance deficiency. The finding is more than minor because it is associated with the reactor safety, mitigating systems cornerstone attribute of protection against external factors (i.e., fire). The excessive emergency lighting unit failures affected the objective of ensuring the reliability and capability of operator manual actions during response to initiating events. The team determined that this finding was of very low safety significance (Green) because the operators had a high likelihood of completing the tasks using flashlights. The cause of this finding has a cross-cutting aspect in the Work Control component of the Human Performance area, in that it was directly related to the licensee not planning and coordinating work activities to support long-term equipment reliability, and their maintenance scheduling was more reactive than preventive (H.3 (b)) |
| Site: | Browns Ferry |
|---|---|
| Report | IR 05000259/2009009 Section 1R05 |
| Date counted | Dec 31, 2009 (2009Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.05 |
| Inspectors (proximate) | G Pick K Miller L Suggs M Thomas P Fillion P Qualls R Nease |
| CCA | H.5, Work Management |
| INPO aspect | WP.1 |
| ' | |
Finding - Browns Ferry - IR 05000259/2009009 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Browns Ferry) @ 2009Q4
Self-Identified List (Browns Ferry)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||