Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
ML20217C91212 October 1999SER Input Authorizing Licensee Proposed Request to Modify Definition of Core Alteration in Section 1.0 of TS & Update Sections 3/4.1,3.4.3 & 3/4.9 to Reflect Proposed Definition ChangeShutdown Margin
Spiral reload
ML20217F90930 September 1999Monthly Operating Repts for Sept 1999 for LaSalle County Stations,Units 1 & 2.WithCoast down
ML20217A16922 September 1999Part 21 Rept Re Engine Sys,Inc Controllers,Manufactured Between Dec 1997 & May 1999,that May Have Questionable Soldering Workmanship.Caused by Inadequate Personnel Training.Sent Rept to All Nuclear Customers
ML20212C45031 August 1999Monthly Operating Repts for Aug 1999 for LaSalle County Station,Units 1 & 2.WithCoast down
ML20210R06731 July 1999Monthly Operating Repts for July 1999 for LaSalle County Station,Units 1 & 2.WithZebra Mussel
Downpower
ML20210C1689 July 1999Seventh Refueling Outage ASME Section XI Summary ReptPacking leak
Hydrostatic
VT-2
ML20209H15030 June 1999Monthly Operating Repts for June 1999 for LaSalle County Station,Units 1 & 2.WithZebra Mussel
Downpower
Coast down
ML20195J78731 May 1999Monthly Operating Repts for May 1999 for LaSalle County Station,Units 1 & 2.WithZebra Mussel
Downpower
ML20209E14331 May 1999Cycle 8 COLR, for May 1999
ML20195B25919 May 1999Rev 66a to CE-1-A,consisting of Proposed Changes to QAP for Dnps,Qcs,Znps,Lcs,Byron & Braidwood StationsOffsite Dose Calculation Manual
Process Control Program
ML20206N20730 April 1999Monthly Operating Repts for Apr 1999 for LaSalle County Station,Units 1 & 2.WithDownpower
ML20205L84231 March 1999Rev 2 to EMF-96-125, LaSalle Unit 2 Cycle 8 Reload AnalysisAnticipated operational occurrence
Feedwater Controller Failure
Fuel cladding
ML20205L83031 March 1999Administrative Technical Requirements App B (Amend 26) LaSalle Unit 2 Cycle 8 COLR & Reload Transient Analysis Results, for Mar 1999
ML20205R27231 March 1999Monthly Operating Repts for Mar 1999 for LaSalle County Station,Units 1 & 2.WithDownpower
ML20205L83922 March 1999Rev 2 to 960103, Neutronics Licensing Rept for LaSalle Unit 2,Cycle 8Shutdown Margin
ML20204C81428 February 1999Monthly Operating Repts for Feb 1999 for LaSalle County Station,Units 1 & 2.WithDownpower
ML20199E46031 December 1998Monthly Operating Repts for Dec 1998 for LaSalle County Station,Units 1 & 2.With
ML20207C73731 December 1998Annual Rept for LaSalle County Station for Jan 1998 Through Dec 1998Loop seal
Packing leak
Fire Barrier
FLEX
Scaffolding
Downpower
ML20205M70631 December 1998Unicom Corp 1998 Summary Annual Rept. with
ML20198B38014 December 1998SER Accepting one-time Request for Relief from Certain Provisions of Section XI of ASME Boiler & Pressure Vessel Code,Per 10CFR50.55a for Certain Plant Safety/Relief Valves
ML20206N2269 December 1998LER 98-S03-00:on 981116,protected Area Was Entered Without Current Authorization for Unescorted Access Due to Programmatic Deficiency Error.Changed Badge Control ProcessFitness for Duty
ML20197K09830 November 1998Monthly Operating Repts for Nov 1998 for LaSalle County Station,Unts 1 & 2.WithDownpower
ML20196B14423 November 1998Safety Evaluation Accepting Licensee Response to GL 95-07, Pressure Locking & Thermal Bindings of Safety-Related Power-Operated Gate ValvesPower-Operated Valves
Backfit
ML20196A41919 November 1998Safety Evaluation Accepting QA TR CE-1-A,Rev 66 Re Changes in Independent & Onsite Review Organization by Creating NSRB
ML20195D31931 October 1998Monthly Operating Repts for Oct 1998 for LaSalle County Station.WithDownpower
ML20154H67830 September 1998Monthly Operating Repts for Sept 1998 for LaSalle County Nuclear Power Station,Units 1 & 2Downpower
ML20153D01918 September 1998Part 21 Rept Re Defect in Gap Conductance Analyses for co- Resident BWR Fuel.Initially Reported on 980917.Corrective Analyses Performed Demonstrating That Current Operating Limits Bounding from BOC to Cycle Exposure of 8 Gwd/MtuFuel cladding
ML20153C76218 September 1998Safety Evaluation Acceping NRC Bulletin 95-002, Unexpected Clogging of RHR Pump Strainer While Operating in Suppression Pool Cooling ModePast operability
Foreign Material Exclusion
ML20153C67717 September 1998Part 21 Rept Re Defect Relative to MCPR Operating Limits as Impacted by Gap Conductance of co-resident BWR Fuel at Facilities.Operating Limit for LaSalle Unit 2 & Quad Cities Unit 2 Will Be Revised as Listed
ML20151W02431 August 1998Monthly Operating Repts for Aug 1998 for LaSalle County Station.WithHalf scram
ML20237E29221 August 1998Special Rept:On 980811,channel 5 of Lpms Became Inoperable. Caused by Channel Failed pre-amplifier Located Inside Primary Containment at Inboard Side of Electrical Penetration E-19.Initiated Repairs of Channel
ML20237E23321 August 1998Revised Pages of Section 20 of Rev 66 to CE-1-A, QA Topical ReptOffsite Dose Calculation Manual
Process Control Program
Fire Protection Program
ML20237B48631 July 1998Monthly Operating Repts for July 1998 for LaSalle County Nuclear Power Station Units 1 & 2
ML20236V77031 July 1998Revised LaSalle Unit 1 Cycle 8 COLR & Reload Transient Analysis ResultsShutdown Margin
ML20236P82314 July 1998Special Rept:From 980614-17,various Fire Rated Assemblies Were Inoperable for Period Greater than Seven Days.Caused by Test Equipment Being Routed Through Fire Doors.Established Fire Watches & on 980619 Assemblies Were Declared OperableSafe Shutdown
ML20236N6759 July 1998Part 21 & Deficiency Rept Re Notification of Potential Safety Hazard from Breakage of Cast Iron Suction Heads in Apkd Type Pumps.Caused by Migration of Suction Head Journal Sleeve Along Lower End of Pump Shaft.Will Inspect Pumps
ML20236L8046 July 1998Safety Evaluation Granting Licensee 980304 Request for Second 10-yr Interval Pump & Valve IST Program Plan,Rev 2, Including Changes to 2 ASME Boiler & Pressure Vessel Code Relief Requests Previously Submitted in Rev 1Breakaway torque
Backfit
ML20236P36130 June 1998Monthly Operating Repts for June 1998 for LaSalle County Nuclear Power Station,Units 1 & 2
ML20249C48922 June 1998Special Rept:On 980522,Fire Detection Zone 1-31 Was Noted out-of-service for More than 14 Days.Detection Sys Was Taken out-of-service on 980508 to Prevent False Alarms During Hot Work Activities.Sys Was Returned to Operable Status 980528Fire Watch
ML20248M31031 May 1998Monthly Operating Repts for May 1998 for LaSalle County Nuclear Power Station,Units 1 & 2
ML20236V77731 May 1998Rev 1 to 24A5180, Supplemental Reload Licensing Rept for LaSalle County Station Unit 1 Reload 7 Cycle 8Anticipated operational occurrence
ML20217Q7044 May 1998Safety Evaluation Accepting Util Request to Leave Leak Chase Channels Plugged During Performance of Containment ILRTLiquid penetrant
ML20247M44930 April 1998Monthly Operating Repts for Apr 1998 for LaSalle County Station
ML20216F49431 March 1998Monthly Operating Repts for Mar 1998 for LaSalle County Station,Units 1 & 2
ML20217N65830 March 1998Special Rept on Fire Detection,Deluge Sys & Fire Rated Assemblies During Period of 980303-25.Established Fire Watches Until Affected Equipment Is Returned to Operable StatusSafe Shutdown
Fire Barrier
ML20216D95128 February 1998Monthly Operating Repts for Feb 1998 for LaSalle County Station,Units 1 & 2
ML20247M46328 February 1998Rev Monthly Operating Rept for Feb 1998 for LaSalle County Station
ML20203D72420 February 1998Special Rept:On 980118,Fire Detection Zones 1-18 & 2-18 Taken out-of-svc to Prevent False Alarms During Hot Work Activities on Auxiliary Electric Equipment Room Ventilation Sys.Fire Watches Will Remain in PlaceSafe Shutdown
Fire Barrier
ML20202G98531 January 1998Monthly Operating Repts for Jan 1998 for LaSalle County Station,Units 1 & 2
ML20199K16523 January 1998Rev 65h to Topical Rept CE-1-A, Comm Ed QA TrSafe Shutdown
Shutdown Margin
Non-Destructive Examination
Offsite Dose Calculation Manual
Hydrostatic
Coatings
Nondestructive Examination
Temporary Modification
Process Control Program
Fire Protection Program