ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: Palisades Date of Examination: July 2008 Exam Level: RO SRO-I SRO-U Operating Test Number: 1 Control Room Systems
@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF) System / JPM Title Type Code* Safety Function a. N/A - RO Only b. Manually Initiate Containment Isolation (SRO-U) (2 valves in series don't close) A,D,EN 2 c. PORV Lifting After Block Valve Opening (SRO-U) (PORV lifts, must close block valve) A,L,N 3 d. Sample Containment for Hydrogen A,D 5 e. N/A - RO Only f. N/A - RO Only g. N/A - RO Only h. N/A - RO Only In-Plant Systems
@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U) i. Outside Control Room 'B' S/G ESDE Isolation per EOP Supplement 18 (SRO-U) E,M,R 4s j. Locally Start and Load 1-1 D/G (SRO-U) A,D 6 k. N/A - RO Only
@ All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.*Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in-plant (EN)gineered safety feature (L)ow-Power / Shutdown (N)ew or (M)odified from bank including 1(A)
(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3
< 9 / < 8 / < 4 > 1 / > 1 / > 1 - / - / > 1 (control room system)
> 1 / > 1 / > 1 > 2 / > 2 / > 1 < 3 / < 3 / < 2 (randomly selected)
> 1 / > 1 / > 1 ES-301, Page 23 of 27