ML20127G617

From kanterella
Revision as of 08:15, 10 July 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Advises That on 780202,during Surveillance Test,One Suppression Chamber to Drywell Vacuum Breaker Failed to Reclose Following Exercise.Plant Shutdown Initiated
ML20127G617
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 02/02/1978
From: Eliason L
NORTHERN STATES POWER CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
NUDOCS 9211170393
Download: ML20127G617 (1)


Text

. . -. . .- - - - . _- . . - - . - - -

rl i (

y 1

NN EGliuliGTN DDCEIFLECOPY

, NORTHERN STATES POWER COMPANY

. n f,h I

Nonticello Nuclear Generating Plant fbnticello, blinnesota 55362

/N j 'l l G $il, hi ,^t D w

, 8 j February 2, 1978 ~~

re07 Ib70" 6*%

l l rear Mr. J. G. Keppler, Director ' N JTf;fb i Region III -

Office of Inspection and Enforcement United States Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137

Dear Mr. Keppler:

?DNTICELLO NUCLEAR GENERATING PLANT i Docket No. 50-263 License No. DPR-22 On February 2,1978, during a surveillance test, one suppression chamber to drywell vacuum breaker failed to reclose following exercise. Plant shut-

+

down has been initiated in accordance with the Technical Specifications.

Further investigation of this occurrence is continuing.

Yours very truly,

/>, < L D,Ax c ed c,, bv,. (.w -

r L. R. Eliason Plant Manager i

i LRE/sdd cc: ifrector, Office of hhnagement Information and Program Control

. File

-Copy sent by telecopier to Keppler.

l d

ojo my y.e 9211170393 780202 .

PDR ADOCK 05000263 S , PDR u

_