ML20071N436

From kanterella
Jump to navigation Jump to search
Ro:On 820928,crack Indication in End Cap of a Recirculation Riser Confirmed by Radiography.Indications Initially Detected by Ultrasonic Exam During Normal Inservice Insp. Remedial Measures Under Investigation
ML20071N436
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 09/28/1982
From: Shamla W
NORTHERN STATES POWER CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
NUDOCS 8210080117
Download: ML20071N436 (1)


Text

V/ Northem States Power Company 414 Nicollet Mall Minneapolis, Minnesota 55401 Telephone (612) 330-5500 Mcnticello !bcler Generating Plt.nt P.O. Box 6 00 Mcnticello, MN 55362 September 28, 1982 Mr. J. G. Veppler, Director Ibgicn III Office of Intpecticn and D1forcement U.S. Ibclear Ibgulatory Ccmnissicn 799 Roomvelt Boad Glen Ellyn, IL 60137

Dear Mr. VcIpler,

MOtEICELIO IKEIER GEtEIRTI?G PIAtE Docket Ib. 50-263 Licenm tb. DPR-22 Q1 September 28, 1982 a crack like indicaticn was ccnfirmed by radiography to exist in the end cap of the 22 inch diameter "A" recirculaticn sfstan rimr nanifold. Them indicaticns were initially detectcd by ultrascnic examinaticn during normal inmrvice inspecticn.

This occuric,ce is being reported in accordance with IbcInical Specificaticn 6.7.B.1.c. Pcmxlial measures are under investigaticn.

Yours veg/ truly, I l hsj W W. A. Shamla Plant Itinager c: Director; Office of Management Informaticn and Program Ccntrol File Copy sent ly telecopy to Keppler IRS /hiz (OCT, 1 22

,'0210000117 820928 i PDR ADOCK 05000263

, ,0 PDR ,

[M$