ML091520121

From kanterella
Revision as of 13:02, 12 March 2020 by StriderTol (talk | contribs) (StriderTol Bot change)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
ES-301-2 SRO R1, Control Room/In-Plant Systems Outline
ML091520121
Person / Time
Site: Palisades Entergy icon.png
Issue date: 07/07/2008
From:
NRC/RGN-III
To:
Entergy Nuclear Palisades
Shared Package
ML082200310 List:
References
Download: ML091520121 (1)


Text

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: Palisades Date of Examination: July 2008 Exam Level: RO SRO-I SRO-U Operating Test Number: 1 Control Room Systems (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)

Safety System / JPM Title Type Code*

Function

a. N/A - RO Only
b. Manually Initiate Containment Isolation (SRO-U) (2 valves in series dont A,D,EN 2 close)
c. PORV Lifting After Block Valve Opening (SRO-U) (PORV lifts, must A,L,N 3 close block valve)
d. Sample Containment for Hydrogen A,D 5
e. N/A - RO Only
f. N/A - RO Only
g. N/A - RO Only
h. N/A - RO Only In-Plant Systems (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
i. Outside Control Room B S/G ESDE Isolation per EOP Supplement 18 E,M,R 4s (SRO-U)
j. Locally Start and Load 1-1 D/G (SRO-U) A,D 6
k. N/A - RO Only

@ All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path 4-6 / 4-6 / 2-3 (C)ontrol room (D)irect from bank <9 / <8 / <4 (E)mergency or abnormal in-plant >1 / >1 / >1 (EN)gineered safety feature - / - / > 1 (control room system)

(L)ow-Power / Shutdown >1 / >1 / >1 (N)ew or (M)odified from bank including 1(A) >2 / >2 / >1 (P)revious 2 exams <3 / <3 / < 2 (randomly selected)

(R)CA >1 / >1 / >1 (S)imulator ES-301, Page 23 of 27