Interim Deficiency Rept DR-109 Re Velan 3/4-inch Socket Welded Globe Valves W/Counterbores Not Concentric to Ctr of Valves.Initially Reported on 830408.AE Evaluation Awaited.Next Rept Will Be Submitted by 830804
ML20024A515
Person / Time
Site: River Bend Entergy icon.png
Issue date: 06/13/1983
From: Booker J
GULF STATES UTILITIES CO.
To: Jay Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
10CFR-050.55E, 10CFR-50.55E, DR-109, RBG-15-240, NUDOCS 8306170395
Download: ML20024A515 (1)


Text

r GULF STATES PoSTOFFicEBOX 2951 UTILITIES COMPANY

= BEAUMONT. TEXAS 77704 Ye2 AREA CODE 713 838-6631 June 13, 1983 RBG- 15,240 File Nos. G9.5, G9.25.1.1 Mr. John T. Collins, Regional Administrator U. S. Nuclear Regulatory Commission Region IV, Office of Inspection and Enforcement 611.Ryan Plaza Drive, Suite 1000 I

_ .f?]p5J q r 7

Arlington, Texas 76011 l l

o! JUNISIE

Dear Mr. Collins:

River Bend Station Unit 1 Docket No. 50-458 J Interim Report /DR-109 On April 8, 1983, Gulf States Utilities Company (GSU) notified Region IV of a condition potentially reportable under 10CFR50.55(e) concerning Velan 3/4", 600 pound, socket-welded globe valves with counterbores that are not concentric to the center of the valves (DR-109). The nonconcentric counterbores may cause welding problems and/or the violation of minimum wall thickness. GSU is awaiting additional information from our architect-engineer. An interim or final status report will be submitted by August 4, 1983.

Sincerely,

. A J. E. Boner Manager-Engineering, Nuclear Fuels & Licensing River Bend Nuclear Group JEB/PJD/kt cc: Director of Inspection & Enforcement U.~ S. Nuclear Regulatory Commission Washington, D. C. 20555 R. L. Brown (SRI) 8306170395 830613