ML18081A119

From kanterella
Revision as of 10:12, 3 February 2020 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Rosemount Nuclear Instruments, Inc., Submittal of Notification Under 10 CFR Part 21 for Certain Model 1154 and Model 1154 Serles H Pressure Transmitters and 01154-0153-0002 Amplifier Circuit Card Assemblies
ML18081A119
Person / Time
Site: Arkansas Nuclear, Waterford  Entergy icon.png
Issue date: 03/15/2018
From: Pham D
Rosemount Nuclear Instruments
To:
Office of Nuclear Reactor Regulation
References
Download: ML18081A119 (1)


Text

Mar/15/2018 9:48:27 AM EPM OUT RMT NUCLEAR 952-949-5201 1/5 EMERSON~* 8200 Market Bpulevard Chanhassen, MN 55317 USA Facsimile Tel 1 (952) 949-5210 Fax 1 (952) 949-5201 No. of Pages: 6 lnaludlng aovt,r p1iig11 To: NRC Operations Center Fax Number: (301) 816~5151 Date: Thursday, March 15, 2018 From: Duyen Pham, Quality Phone: (952)949-5363 Manager E-Mail: Duyen.Pham@Emerson.com

Subject:

Notification under 10 CFR Part 21 for Certain Model 1154 and Model 1154 Serles H Pressure Transmitters and 01164-0163-0002 Amplifier Circuit Card Assemblies Rosemount Nuclear Instruments, lnc. is submitting the attached updated notification as required by 1o CFR Part 21 with the date on which the information of such defect or failure to comply was obtained added to Section 4.0.

Please contact me if you have any questions.

Sincerely, Duyen Pham Quality Manager Rosemount Nuclear Instruments, Inc.

Mar/15/2018 9:48:27 AM EPM OUT RMT NUCLEAR 952-949-5201 2/5 Ro*smount Nuclear Instruments, Inc.

8200 Markel Boulevard ,

Cha.nha11aen, MN 55317 USA Tai 1 (952) 949-5210 Fa,.; 1 (952) 949*5201 Y'J,.'ltl-Rgsemovnlliucleli(.com 15 March 2018' U.S. Nuclear Regulatory Commission Washington, DC 20555~001 Attn: Document Control Desk18 Ra: Notification under 10 CFR Part 21 for Certain Model 1154 and Model 1164 Sarles H Pressure Tranamitters and 01154-0153-0002 Amplifier Circuit Card Assemblies

(

Pursuant to 10 CFR Part 21, section 21.21 (b). Rosemount Nuclear Instruments, Inc. (RNII) is writing to inform you that a total of eleven (11) Model 1154 and 1154 Series H output range code 4 pressure transmitters whose model code includes special option suffix N0026 or N0087 and five (5) 01154-0153-0002 Amplifier Circuit Card Assemblies as listed in the attached Appendix may not callbrate at all the published values.

\

1.0 Name and address of the individual providing the Information:

Mr; Gerard Hanson Vice President & General Manager Rosemount Nuclear Instruments, Inc.

8200 Market Blvd Chanhassen, MN 55317 2.0 Identification of items supplied:

Eleven (11) Model 1154 and 1154 Series H output range code 4 pressure transmitters whose model code includl;ls special option suffix N0026 or N0087 and five (5) 01154-0153-0002 Amplifier Circuit Card Assemblies as identified In the attached Appendix.

The.01154-0153"0002 Amplifier Circuit Card Assembly is used only with output code R over-ranged range code 4 options Including ND026 and N0087.

3.0 Identification of firm supplying the Item:

Rosemount Nuclear Instruments, Inc.

8200 Market Blvd Chanhassen, MN 55317 4.0 Nature of the failure and potential safety hazard:

During evaluation of two returned 01154-0153-0002 Amplifier Circuit Card Assemblies (CCAs), It was observed that a single resistor (R316) on each affected Amplifier CCA had an incorrect resistance value.

  • Page 1 of 3

Mar/15/2018 9:48:27 AM EPM OUT RMT NUCLEAR 952-949-5201 3/5 The N0026 and N0087 special options enable a standard upper range limit (URL) of a transmitter with output range code 4 to be Increased from 150 lnH20 to 210 lnH20, In combination with a minimum span of 75 inH20. This R316 resistor allows the transmitter to achieve performance specifications, callbratlon ranges, and spans as indicated by the special option drawing.

In the sub-assembly process, the R316 resistor on a standard Amplifier CCA is replaced to create a new Amplifier CCA part number (01154-0153-0002). The R316 resistor enables the standard lower range limit (LRL) of a transmitter with output range code 4 to be decreased from -150 inH20 to ~210 inH20 (negative pressure values imply pressure applied td the low-,pressure side of the transmitter), in combination with a minimum span of 75 lnH20. This R316 resistor allows the transmitter to achieve performance specifications, calibration ranges, and spans as indicated by the special option drawing.

The new resistor's material traceability information is recorded on the traveler. In final assembly, each transmitter with spacial option suffix N0026 and N0087 is assembled using one of these 01154-0153-0002 Amplifier CCAs. It then receives a factory calibration check at 135 inH20 to 210 inH20 and customer specified calibrated range, to ensure conformance to the minimum span and maximum URL specifications, as defined by the special option drawing. Appropriate manufacturing papeiwork is used to document and record each Amplifier CCA serial number, as well as each final assembly transmitter.

To meet site specific appli6ation requirements, transmitters may be field recalibrated to different upper and lower range values and/or spans. Model 1154 and 1154 Series H transmitters with special option suffix NOD26 or N0087 and Amplifier CCAs whose R316 resistors were not replaced during the sub-assembly process, will have Incorrect resistance values and may not calibrate to all upper and lower range values and/or spans published for the applicable special option. However, if an affected transmitter has been successfully calibrated, having the incorrect resistance value will not adversely affect transmitter performance specifications during normal operation or accident conditions.

The manufacturing records for the two returned Amplifier CCAs, part number 01154-0153-0002, were carefully reviewed. The sulrassembly traveler lacked the required material

.- traceabll!ty Information, Indicating that the R316 resistors were not replaced. RNII reviewed all sub-assembly travelers for part number O1154-0153-0002. The issue has been isolated to one lot which included (16) Amplifier CCAs.

On March 8, 2018, RNII concluded that a substantial safety hazard may exist.

5.0 The corrective action which has been taken; the name of the individual or organi:tation responsible for that action; and the length of time taken to complete that action:

r

{a} RNII previously discontinued manufacturing 01-154~0153-0002 Amplifier CCAs, there are no Amplifier CCAs currently In production or finished goods.

(b) RNII examined all manufacturing papetwork for all 01154~0153~0002 Amplifier CCAs, and other than the single lot of (16) Amplifier CCAs described above, no additional discrepancies were found.

+

EMERSON. Page 2 of 3

Mar/15/2018 9:48:27 AM EPM OUT RMT NUCLEAR 952-949-5201 4/5 6.0 Any advice related to the potentlal failure of the Item:

The end user is advised to determine the impact of this potential non-conformance on Its plant operations and safety and take action as deemed necessary. Affected 01154-0153..

0002 Amplifier CCA(s) and transmitter(s) can be returned to RNI I for rework. Contact RNI I to facilitate the return process.

Rosemount Nuclear Instruments, Inc. is committed to the nuclear industry and ,we assure you that we are dedicated to the supply of high quality products and services to our*

customers. If there are any questions, or you require addltlonal Information related to this issue, please contact: Mike Dougherty (208) 865-1112, Paul Schmeling (952) 949-5359, or Brian Vanderwoude (952) 949-5207.

Sincerely, Gerard Hanson Vice President & General Manager Rosemount Nuclear Instruments, Inc.

+

EMERSON. Page 3 of 3

Mar/15/2D18 9:48:27 AM EPM OUT RMT NUCLEAR 952-949-52D1 5/5 EMERSON .

~

Rosemount Nuclear Instruments, Inc.

8200 Market eculevard Chanhassen, MN 56317 USA Tel 1 (952)94~5210 Fax 1 {952) 949-5201

)CJWW.RosemoyntNucJesc com APPENDIX A: 10 CFR Part 21 Notificatlon-15 March 2018 Shipped as piece parts (P/N 01154-0153-0002)

Purchase Sales CCA Serial Ship

'~ Customer Site Order Order Number Date 10414134 3884268 0151667 Entergy ANO 6/27/14 10414134 3684268 0151706 Entergy ANO 6/27/14 10431750 4140165 0151869 Entergy ANO 2/18/16 10423801 3994314 0151918 Entergy ANO 11/3/14 10421255 4079414 0151790 Entergy Waterford 1/19/15 Shipped as part of transmitter (N0026 and N0087)

Purchase Sales Transmitter CCA Ship Order Order Mooel Number SIN S/N customer Site Date 500581048 3818701 1154DP4RAN0026 0552968 0161846 Pinnacle Palo 6/5/14 West Verde 500581048 3818701 1154DP4RAN0026 0552969 0151928 Pinnacle Pello 6/5/14 West Verde 500581048 3818701 1154DP4RAN0026 0652970 0151937 Pinnacle Palo 6/5/14 West Verde 500681048 3818701 11S4DP4RAN0026 0552971 0151810 Pinnacle Palo 6/5/14 west Verde 500561048 3818701 1154DP4RANOD26 0552972 0151819 Pinnacle Palo 6/5/14 West Verde 500581048 3818701 1154DP4RAN0026 0552973 0151696 Pinnacle Palo 6/5/14 West Verde 500581048 3818701 1154DP4RAN0026 0552974 0151914 Pinnacle Palo 8/5/14 West Verda 500581048 3818701 1154DP4RAN0026 0552975 0151664 Pinnacle Palo 6/5/14 West Verde 02301969 3840060 1154DP4RAN0026 0552976 0151B2B FP&L St. 6/2/14 REL 00013 Lucie 443261 3856762 1154HH4RCN0087 0553320 0146161 Constellation Calvert 7/16/14 Cliffs 443261 3855762 1154HH4RCN0087 0553321 0151689 Constellation Calvert 7/16/14 Cliffs Page 1 of 1