ML21260A007

From kanterella
Jump to navigation Jump to search
Ametek Solidstate Controls, Notification of Potential Defect - 10CFR Part 21 Report Re Omron Timer Relay
ML21260A007
Person / Time
Site: Beaver Valley, Millstone, Nine Mile Point, Palisades, Kewaunee, Watts Bar, Arkansas Nuclear, Braidwood, Brunswick, Cook  Constellation icon.png
Issue date: 09/09/2021
From: Salsbury E
AMETEK, Paragon Energy Solutions
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
EN 55453
Download: ML21260A007 (5)


Text

SOLIDSTATE CONTROLS Quality Assurance 875

Dearborn Drive,

Columbus, OH 43085 U.S.A.

Telephone: 614-846-7500; 1-800-635-7300 E-mail: ethan.salsbury@ametek.com 9/9/2021 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Attention: Document Control Desk

Subject:

Notification of Potential Defect - 10CFR Part 21 Product: Omron Timer Relay, part number H3CR-A-AC100-240/DC100125 Ametek Solidstate Controls is submitting the following Report of a Potential Defect in accordance with the requirements of 10CFR21. This notification is applicable to equipment with the following model number prefixes:

55-CCXXXX-XX 85-CCXXXX-XX 85-VCXXXX-XX The attached document provides details on the potential problem, cause and effect, and actions required. Also provided below is a list of specific equipment affected by this issue. Please contact us at the phone number or email provided above if there are any questions.

Sincerely, Ethan Salsbury Quality Director Ametek Solidstate Controls

COMPONENT DESCRIPTION:

AMETEK Part Number 07-740108-00, K306 relay, used in the float/equalize circuit of AMETEK Battery Chargers. The relay is a solid-state timer manufactured by Omron with manufacturer part number H3CR-A-AC100-240/DC100125.

PROBLEM YOU COULD SEE:

AMETEK was notified of a condition of a nonconforming K306 relay that led to failures of battery chargers.

AEP DC Cook reported a single failure of a K306 Float/Equalize timer relay in a controlled environment where the relay failed to transfer from float to equalize and caused the DC output to fail. Transferring the battery charger to equalize mode is always a manual operation and the float/equalize function is typically used after an outage or a discharge test in order to bring the batteries back to full charge. Before performing a discharge test, the charger should be put in equalize mode.

AMETEK was not able to evaluate this specific instance of failure, but it was determined the circuit does not meet the minimum contact current rating. As a result, the operation of the relay may be unreliable and the charger may experience a loss of output when equalize is initiated, failing to charge the batteries. The failed relay was installed in 2017 and was original to the equipment.

Extent of Condition Equipment with this relay installed is listed in Appendix A of this report.

CAUSE:

High contact resistance on the K306 normally open contacts in series with the Equalize control potentiometer caused the DC output voltage to decrease. Cycling the AC input breaker off and on will restart the charger and return the charger to float. To get the charger to equalize, the float potentiometer can be increased to the equalize voltage.

The relay manufacturer specifies the minimum relay contact current rating of 10mA at 5VDC. In the float/equalize circuit, the current applied is approximately 0.6mA to 0.7mA at 15VDC. The relay contact may not make contact consistently as the minimum current contact rating is not met when installed in the circuit. Any potential oxidation built up on the contacts would further reduce the relays ability to transfer correctly. Based on previous aging analyses, the lifetime of the relay exceeds 300 years. However, this does not account for oxidation and aging that may limit reliable operation.

In the instance of failure reported, replacing the K306 relay allowed the battery charger to transfer between float and equalize correctly.

EFFECT ON SYSTEM PERFORMANCE:

If the charger fails to transfer between float and equalize, the equalize light may turn on, the charger output will fail, voltage will drop below float voltage or to 0, and there will be no charging capabilities. An alarm will indicate Low DC voltage in the event the charger does not transfer between float and equalize. The charger will restart after the AC input breaker is cycled Off and On. The relay should be replaced if the charger output is lost. Other alarm(s) may be included with the design:

Battery Discharge Alarm Low Current Alarm The battery will charge with float voltage, but will take longer than with equalize voltage (~8-24 hours after charging current stabilizes)

The safety impact is a loss of battery charger output after an event where the float/equalize button is utilized and does not retransfer to equalize for charging. If the charger fails to transfer and the output is lost prior to a safety event, the battery may not be at full capacity for a shutdown. Each utility will need to evaluate the application of the battery charger and the battery it is charging.

ACTION REQUIRED:

This relay is integrated into the design of all AMETEK battery chargers. AMETEK has not experienced a significant number of failures relative to the quantities installed over the past 30 years and is not aware of widespread failures of this part. There have not been any trends in warranty or internal failures of this component. The incidents reported by AEP were the first on file that occurred early in the components life. Typical failures of the K306 relay occur after many years in operation beyond the recommended replacement schedule of 10 years.

AMETEK is still seeking a direct replacement alternative to be used in the circuit with a higher minimum contact current rating. As an alternative enhancement to the reliability of the K306 relay, a reed relay board is being designed to increase the circuit current to meet the minimum contact current rating.

Estimated completion of the reed relay board is early 2022. This will include options for retrofitting to existing equipment along with the necessary seismic justification and replacement schedules.

The timer relay is currently on a 10-year preventative maintenance schedule. In the interim, affected utilities should consider replacing relays at 2-year intervals to avoid any disruption of operation. Routine operation should prolong the lifetime of the relay by reducing the oxidation buildup on the contacts. The relay can be cycled on a quarterly basis to extend this replacement to 5 years. The replacement and cycling time periods are based on conservative estimates of oxidation and the operation history of these relays.

The K306 relay should be tested annually to determine if any oxidation is impacting performance. AMETEK will update the operation manual to instruct users to transfer from float to equalize every outage, at minimum. Additionally, spare components should be available as a backup if a failure during transferring to equalize occurs.

AMETEK SOLIDSTATE CONTROLS CORRECTIVE ACTION:

AMETEK Solidstate Controls will work with you to arrange replacements and spare parts for your application as needed. Please contact our Client Services group at 1-800-222-9079 or 1-614-846-7500, extension 1.

Appendix A Customer Job Number Model ALABAMA POWER COMPANY 96000039 85-VC0075-32 85-VC0075-35 C94324 85-CC0250-01 85-CC6000-29 ARKANSAS NUCLEAR ONE C60185 C65853 85-CC4000-51 85-CC4000-67 ATOMIC ENERGY OF CANADA C72921 85-CC1500-77 85-CC3500-09 CONSTELLATION ENERGY 94000960 85-CC5000-71 C86206 85-CC0500-71 85-CC0500-72 85-CC3000-135 85-CC3000-136 CONSUMER'S POWER, PALISADES C64245 85-CC2000-71 DOMINION - KEWAUNEE C101778 85-CC1500-96 DOMINION ENERGY 96000166 85-CC4000-104 DOMINION INC.

96000088 96000126 96000149 85-CC2500-46 85-CC2500-47 85-CC2500-48 DUKE ENERGY 96000070 85-CC3000-148 C69374 85-CC0500-36 C80148 85-CC5000-68 C92133 85-CC3000-140 DUKE POWER CO C55043 85-CC0750-12 C55043 85-CC3000-64 85-CC6000-18 C62608 85-CC4000-87 EM TEST (SWITZERLAND) GMBH 96000084 85-CC0200-24 ENGINE SYSTEMS C102106 55-CC0500-13 ERGYTECH INC.

C73423 85-CC6000-27 85-CC6000-28 EXELON 96000151 85-CC3000-150 96000169 85-CC2000-126 EXELON GENERATION CO C78494 85-CC2000-100 85-CC2000-102 85-CC2000-99 85-CC2000-101 C80146 85-CC2000-103

Customer Job Number Model 85-CC2000-104 FIRST ENERGY C102800 85-CC6000-31 85-CC6000-33 85-CC6000-32 85-CC6000-34 FORMOSA NEXTECH CO 96000095 85-CC3000-149 85-CC5000-72 FRAMATOME TECHNOLOGIES C72400 85-CC0500-40 85-CC0500-41 GEORGIA POWER C102225 85-CC4000-99 85-CC4000-102 C97060 85-CC3000-142 85-CC2000-115 85-CC2000-116 C97060 85-CC4000-96 96000083 96000051 85-CC1000-64 C97060 85-CC4000-97 INDIANA MICHIGAN POWER CO 96000079 85-CC0250-03 85-CC0250-04 85-CC0250-05 MILLSTONE NUCLEAR POWER STATION C61578 85-CC2000-61 NIAGARA MOHAWK 40814 85-CC5000-03 NPP KRSKO 96000092 55-CC3000-18 PROGRESS ENERGY C98245 85-CC3000-146 TVA 96000164 85-CC0200-25 TVA WATTS BAR C98266 85-CC2000-118 85-CC2000-123 ULYSSES - TAIWAN POWER C101985 85-CC1500-97 ULYSSES SYSTEM DEVELOPMENT C72472 85-CC1500-76