LER 80-005/03L-0:on 800123,during Steady State Mode 1 Operation,Reactor Coolant Leakage Calculation Indicated Approx 3.6 Gpm Unidentified Leakage.Caused by Packing on Pressurized Spray Valves Leaking Excessively
ML19296B359
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 02/15/1980
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML19296B355 List:
References
LER-80-005-03L, LER-80-5-3L, NUDOCS 8002200458
Download: ML19296B359 (1)


Text

.

hRC FORM 366 U. S. NUCLE AR REGUL ATORY COMMIS$10N (7 77)

LICENSEE EVENT REPORT EXHIBIT A CONTROL BLOCK: l 1 l \ 6lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATIONI 6

foTil8 9l AlR l Al Nl0 lp [g na h 0 l0 l - j0 l 0 l 0l Oj 0 l- l 0 l0 lg lac (NSE NUMBER 2s 26 l1 l 1l1 l l jgl l lg L6CE NSE t VFL JG bl C.T btl 7 LICENSEE CODE CON'T o i sl,% LL_J@l0 I s p 10 i 01316181Gl01112 ed 69 3 i a l 01@l0127e n 11 1 s 0180 @

syPoHTDaTE 7 8 60 61 DOCK ET hum 8Ep E Vf NT D.TE EVENT DESCRIPTION AND PROB ADLE CONSEQUENCES h oi2 IDuring steady state Mode 1 ooeration. the Reactor Coolant Leakaae calcu- I o llation indicated anoroximately '4 6 GPM unidentifiod leakage exronding that o 4 pilowed by T.S.3.4.6.2.b. A containment building entry was made and it i o s was verified that no pressure boundary leakage existed. The maiority of I t o is 1 Ithe calculated leakaae was identified as that defined by T.S.l .14.a. No I lolilIsimilar occurrences. Renortable nor T-S_6_9.l_9_b. I o a i I

" ' ^

'CS'E '[c"o'E su' ecee towPoNsNT cout .u',Y.E . sMcEE e, ,

i C h l@ LEJ@ LB_J@ l V l A I l IV l E l Xl@ [E_l@ [X_j @

9 ,, ,, ,, ,, ,, i ., 2o

. sf QUE NTIAL OCCUnarNct nrponr PtvisiON Lg n no EVENvvf** S E Po4 T NO C00E TYPt m. O

@ fu'; g ' l 810 I L_-J l olo I s l trJ 101 31 LLJ l3 , -J loj 2n n 23  :. 26 >> n .m .w u TAK(N . TO PLA T VETw HOURS sg IT ,Om

  • sUPPLt R WAN FAC U (R LXJ@LELJ@

3J 34 35 Llj@ L1.J@

36 10 D 1010 Je 0 Llij@

el INi@ LILJ@ IasC 161 31 s4 t@

47 43 C AUSE DESCR.PTION AND CORREC flVE ACTIONS li io l Packing on Pressurizer Soray valves. 2CV-4651 and 2CV-4652. were found to i li t i 1 hp leaking oxenssively. Ioakago frnm narking was ennted thrnngh laak-off I

, 2 Ilines to the Containment Buildina sump. Minor leakage was identified at i 1 i s i Reactor Coolant Pumo "C" seal . Maintenance will be performed on leak I m Isources during February outage. I

~

'b'.'Ws' v owi= orwe sr rus @ Eses $ v' o,scovEmv e,sen,,noN i s L3J@ l1 l 01 d@l l4A I LC_J@l NA l

" .a vi,. co'L E ~T

" '5 * =0-

.e u.s.o o, at u.u .oouNr o, C1,v,1, @ l toc.,,oNo,,,,u.s,@

NA NA li-Ic

' I' LZ' J @ LZ ' J@l "

l l

,insoNNto .. cs " Es ao

,.u ... 1 ,, ci sc.. 1.c,. @

i i 10 0[ Of@[Zj@[ NA l w

,E so~Ne't ,suiis No .c. cesC.,veN@

i x 101010 l@l NA l

7 8 9 11 12 TYPE OtsCRPTON LLLoJ l z.J@l NA A 9 l

7 10 PUSLsCITY "

DE sCa sPTsoN 4S NRC USE ONLY 2

issue LEJ D@lNA 1 l;illll;;i;;l I 8 9 'o CA t,' 9 po NAME OF PREPARER Chris N. Shively ,,0y, MU%b3M 8002200 y