Attachment ts ICAN069806 Page1of127 ARKANSAS NUCLEAR ONE UNIT-1 Steam Generator Inservice Inspection Results j

for the Fourteenth Refueling Outage i

Insnection Summary An inservice eddy current inspection was performed on tubes in the Arkansas Nuclear One, Unit-1 (ANO-1), once through steam generators (OTSGs) "A" and "B" during April 1998. The previous inservice inspection, cWad in September and October 1996, resulted in an eighteen month inspection interval per ANO-1 Technical Specification (TS) 4.18.4.a.

The fourteenth ramaling outage (IR14) i==,aar* ion was conducted in accordance with TS 4.18. Overall, more than 70,000 eddy current examinations were performed on the OTSG tubing. The inWion included a 100% full length tubing examination of both OTSGs. In the "A" and "B" OTSGs respectively,14,%1 and 15,283 tubes without prior repairs were inspected in accordance with TS 4.18.3 using a 0.510" mid-range bobbin probe. The non-repaired upper roll regions (14,488 in "A" and 14,806 in "B") in the OTSGs were inspected with a superprobe containing a plus point coil, a 0.115" paix: axe coil, and a 0,080" pancake coil. A 100% sleeve rolled joint inspection using a plus po*mt coil and a 100% exam of the sleeve freespan was performed using a 0.400" bobbin probe.

Diagnostic testing for characterization of the indications detected by bobbin was also performed on 1,148 indications in the "A" OTSG and 872 indications in the "B" OTSG.

The diagnostic exams performed also allowed cosi!'...ation and length sizing of upper tubesheet intergranular attack (IGA), which was previously diamasad in the C-3 report submitted on May 1,1998 (ICAN059802).

Tables. I and 2 provide the number, j

inspection type, and extent of the tubes m=laad for the "A" and "B" OTSGs, respectively.

l I

9906230239 990615 PDR ADOCK 05000313 e

PDR I'L_____________.

Attachment to 1CAN069806 Page 2 of127 Table i "A" OTSG Inspection Summary

%[ignt :..' ;. t..-

/q; An y.

_'[ ((i ;

~~j M;b..f: : ' ff"ygff @..,

y" ht9 T 1 '.' i ff 1.1.mse y fSagi 6,,y,;;<i; Bobbin Full Length 0.510" Mid-Range LTE-UTE 100 % / 14,575 Bobbin l Below Sleeves l 0.510" Mid-Range l LTE-14S/lSS 100 % /476 MRPC Upper Roll Plus Point, 0.115",

UTE 100 % /14,488 Region 0.080" Pancake Coils Plus Point l _ Sleeve Rolls l Plus Point Coil l Targeted Roll 100% / 476 Sleeves Bobbin l Sleeve Freespan l 0.400" l UTE-14S/15S 100% / 476 Sleeves MRPC ofDents Dents in Plus Point, 0.115",

Various 100 % /102 Superheat 0.080" Pancake Region Coils Diagnostic MRPC Bobbin Plus Point, 0.115",

Various 100 % /1,148 Indications 0.080" Pancake Coils MRPC Lane and Sleeve Border Plus Point, 0.115",

ISS and UTS 100 % / 59 Wedge 0.080" Pancake Coils Secondary Side Various Plus Point, 0.115",

Various 100 % / 7 Anomalies 0.080" Pancake Coils ARC Probe Wear Upper Tubesheet Monitored ISS-UTE 100 % /281 Bobbin IGA 0.510" Mid-Range Bobbin Upper Tubesheet l 0.510" High ISS-UTE 26 % / 72 IGA l

Frequency Post Re-roll IR14 Re-roll Plus Point, 0.115",

UTE 100 % /1,966 MRPC 0.080" Pancake Coils Post Re-roll l

1R14 Re-roll 0.510" Bobbin l

UTE 100 % /1,966 Profilometry l

l MRPC I-690 Rolled 0.115" Pancake UTE 20 % / 66 Plugs Coil ARC = alternate repair criteria LTE = lower tube end S = support plate MRPC = motorized rotating pancake coil UTE = upper tube end UTS = upper tube sheet secondary face 1

Attachment to ICAN069806 j

Page 3 of127

)

Table 2 "B" OTSG Inspection Sumanary NBobbin a

Full Length 0.510 Mid-Range LTE-UTE 100 % / 14,843

'l Bobbin l BelowSleeves l 0.510 Mid-Ranae l LTE-14S/15S l 100 % /484 l

l MRPC Upper Roll Plus Point, UTE 100 % / 14,806 Region 0.115", 0.080" Pancake Coils l

Plus Point l

Sleeve Rolls l Plus Point Coil l Taracted Roll l 100% / 484 Sleeves l

l Bobbin l SleeveFreespan l 0.400" l UTE-14S/15S l 100% / 484 Sleeves l

l MRPCofDents Dents in Plus Point, Various 100 % /58 Superheat 0.115", 0.080" Region Pancake Coils l Diagnostic MRPC Bobbin Plus Point, Vanous 100 % / 872 Indications 0.I15", 0.080" Pancake Coils 1 MRPCLaneand Sleeve Border Plus Point, ISS and UTS 100 % / 44 Wedge -

0.115", 0.080" Pancake Coils l SecondarySide

_ Various Plus Point, -

Various 100 % / 1 Anomalies 0.115", 0.080" Pancake Coils l ARCProbeWear Upper Tubesheet Monitored 15S-UTE 100 % /141 Bobbin IGA 0.510" Mid-Range l

Bobbin Upper Tubesheet l 0.510" High

]

15S-UTE l

36 % /51 l

IGA l

Frequency l

l l

l Post Re-roll IR14 Re-roll Plus Point, UTE 100 % /1,157 MRPC 0.115", 0.080" Pancake Coils l

l Pro 61ometry Post Re-roll IR14 Re-roll 0.510" Bobbin j UTE 100 % /1,157 l

1 l

I i

l MRPC l

I-690 Rolled 0.115" Pancake l UTE 20 % /26 l

l l

Plugs Coil I

I l

l

ICAN069806 Page 4 of127 Inspection Results Tube wall degradation was observed in both the "A" and "B" OTSGs. Six forms of degradation were identified during the IR14 outage. They included upper tubesheet outside diameter intergranular attack (ODIGA), groove ODIGA, primary water stress corrosion cracking (PWSCC) in the upper roll transitions, PWSCC in the upper heat affected zone (HAZ), mechanical wear at the broached tube support plates (TSPs), and defects in the sleeve roll transitions.

The indications detected and confirmed during IR14 were repaired via re-roll or plugged, with the exception of TSP wear depth sized less than 40% through-wall (TW) and the upper tubesheet ODIGA that met the criteria of TS 4.18.5.b.

A summary of the degradation identified during the IR14 outage is provided in Tables 3 and 4 for the "A" and "B" OTSGs, respectively.

E l

Attachment to ICAN069806 Page 5 of127 Table 3 "A" OTSG 1R14 Degradation Summary ll Groove /

Freespan / TSP Bobbin / MRPC 27/55 Volumetric ODIGA Mechanical TSP l Bobbin / MRPC (0.0115" 219/ 237 Wear l

Coil for Sizing)

I Indications Sleeve Sleeve / Tube l Plus Point I/1 Joints l

l PWSCC l

Upper HAZ l

MRPC l

1,850 / 1,873 I

PWSCC Upper Roll l

MRPC 148/180 Transition l

l I

l 1

I

Attachment to l

1CAN069806 Page 6 of127 Table 4 I

"B" OTSG 1R14 Degradation Summary J

Volumetric Upper Bobbin / MRPC 137 / 173 i

ODIGA Tubesheet I Volumetric Groove /

Freespan / TSP Bobbin / MRPC 10 / 22 ODIGA I Mechanical TSP Bobbin / MRPC (0.0115" l 213 / 232 l

Wear Coil for Sizing) l l

l Indications Sleeve Sleeve / Tube Plus Point 0/0 Joints l

PWSCC l

Upper HAZ l

MRPC l

1,048/1,059 l

lPWSCC Upper Roll MRPC 133 / 172 Transition I

I i

4

___.__.__.___m__

l Attachment to ICAN069806 Page 7 of127 Volumetric ODIGA A total of 280 tubes with 332 ODIGA flaws were identi6ed in the "A" OTSG and 137 tubes with 173 ODIGA flaws identified in "B" during the IR14 eddy current inspection.

The indications were detected during the 100% bobbin exam and subsequently confirmed and characterized to be volumetric with the MRPC exam. The five conditions specified by TS 4.18.5.b were met and'were described in the previously submitted C-3 report (ICAN059802).

Tables 5 and 6 provide the location of the volumetric ODIGA indications for the "A" and "B" OTSGs, respectively.

PWSCC at the Unser Tube End Reason A total of 1,850 tubes with 1,873 indications in the "A" OTSG and 1,048 tubes with 1,059 indications in the "B" OTSG that contained indications in the HAZ were identified.

Additionally, there were 180 indications in 148 tubes in the "A" OTSG and 172 l

indications in 133 tubes in "B" with indications in the upper roll transition. Tables 7 and 8 provide the location of the indications in this region for the "A" and "B" OTSGs, respectively.

A root cause analysis concluded that the cause of the cracking was PWSCC occurring as a result of the remaining stresses from the original rolling and welding process coupled with a reactor coolant system temperature of 603' F. Based on the location of the indications across the tubesheet and a tendency toward the periphery, fatigue assisted PWSCC has l

not been discounted. It is thought that the thermal induced tube loads may be of different magnitude on the periphery, and possibly contnbute to the development of the PWSCC.

l-The end region of the OTSG tubes are affected by the stresses created by the rolhng operation and the seal vedsag of the tube to the M-Although the OTSGs received a full vessel stress relief, it is likely that the tube end regions were left with some amount -

ofresidual stress. This stress, along with normal operating stresses and the temperature of the reactor coolant (603' F), is sufEcient to initiate PWSCC. Therefore, the most likely cause of the tube end anomalies is PWSCC. Corrective actions have been identified and are being tracked under the ANO condition reporting system.

Tube Support Plate Mechanical Wear 1

There were 237 wear indications contained within 219 tubes in the "A" OTSG and 232 L

wear indications in 213 tubes in the "B" OTSG. The confirmed wear indications were depth sized using the 0.080" pancake coil from the MRPC examination u described in response to Generic Letter 97-05, submitted on March 17,1998 (OCAN039806). Tables 9 and 10 provide the indication location and the corresponding depth size of the flaws for the "A" and "B" OTSGs, respectively.

i l

l

Attachment to ICAN069806 Page 8 cf127 Other Tube Sunnort Plate Indications Six indications were detected and confirmed to be single volumetric indications (SVIs) located in the TSPs in the "A" OTSG. Of the six indications, four were located in the nucleate / film boiling region, below the 8th TSP, and two were located in the superheated region at the 15th TSP. All but two of the indications were small (< 1.0 volt) as determined from the MRPC exam The largest indication is believed to be permeability; however, it was conservatively classi6ed as a SVI. The second largest indication was in-situ pressure tested to 4,400 psi with no leakage. In the "B" OTSG two flaws were confirmed, a SVI at the 7th TSP and a single axial indication (SAI) at the 10th TSP. Both Aaws had amplitudes < 0.50 volts from the MRPC exam The TSP indications appear to be similar to indications detected during previous outages and are not considered to be a new form ofdegradation.

Sleeve Indications i

One sleeve indication was detected in the "A" OTSG. This indication is believed to be an installation induced flaw and detectable at this time due to the lower detection threshold of l

the plus point probe.

Renairs A total of 1,966 tubes were repaired using the re-roll process in the "A" OTSG and 1,157 re-rolled in the "B" OTSG. Indications were detected in the new roll area of tube 99-24 in the "A" OTSG and tube 92-116 in the "B" OTSG. The two tubes were' subsequently plugged. A total of 66 tubes were plugged in the "A" OTSG, while 30 tubes were j

plugged in the "B" OTSG. Tables 13 and 14 provide the tubes that were plugged during 1R14 in the "A" and "B" OTSGs, respectively.

l 1

I I

L - -- --------------

Attachment ta 1CAN069806 Page 9 cf127 Table 5 "A" OTSG Upper Tubesheet Volumetric Indications l

9 l

10 l

UTS

+7.81 l

9 l

23 l

UTS

+5.25 l

9 l

32 l

UTS

+7.04 l

10 l

22 l

UTS

+11.57 l

10 l

35 l

UTS

+6.66 l

11 l

28 l

UTS

+6.17 l

l 11 l

30 l

UTS

+8.21 l

12 l

24 l

UTS

+6.55 l

13 l

25 l

UTS

+7.99 i

l 15 l

37 l

UTS

+8.39

)

l 17 l

44 l

UTS

+19.80 I

l 21 l

49 l

UTS

+5.80 l

23 l

42 l

UTS

+16.22 l

23 l

53 l

UTS

+5.65 I

l 23 l

56 l

UTS

+5.74 l

24 l

16 l

UTS

+9.51 l

25 l

70 l

UTS

+11.60 l

25 l

82 l

UTS

+5.50 l

26 l

55 l

UTS

+7.66 l

26 l

97 l

UTS

+20.77 l

27 l

27 l

UTS

+5.40 l

27 l

31 l

UTS

+5.66 l

27 l

31 l

UTS

+6.81 l

28 l

8 l

UTS

+19.04 l

29 l

53 l

UTS

+4.06 l

30 l

104 l

UTS

+11.67 l

31 l

106 l

UTS

+12.65 l

32 l

94 l

UTS

+7.91 l

34 l

13 l

UTS

+9.30 l

35 l

55 l

UTS

+7.30 l

37 l

12 l

UTS

+6.05 l

37 l

13 l

UTS

+10.12 l

l 37 l

110 l

UTS

+11.79 l

37 l

113 l

UTS

+9.05 l

l 38 l

10 l

UTS

+4.43 l

l 38 l

104 l

UTS

+7.60 l

39 l

47 l

UTS

+6.28 l

40 l

13 l

UTS

+6.75

Attachment to ICAN069806 Page 10 of127 Table 5 (cont)

"A" OTSG Upper Tubesheet Volumetric Indications l

l 40 l

36 l

UTS

+5.32

,j l

40 l

100 l

UTS

+5.64 l

l 41 l

15 l

UTS

+12.36 l

I l

43 l

11 l

UTS

+5.%

l l

l 43 l

105 l

UTS

+12.62 l

l l

43 l

107 l

UTS

+8.76 l

l l

43 l

108 l

UTS

+9.3 5 l

l l

44 l

110 l

UTS 40.39 l

l 45 l

110 l

UTE

-2.73 l

l l

46 l

117 l

UTS

+6.04 l

l 47 l

2 l

UTS

+6.74 l

l 47 l

2 l

UTS

+14.97 l

I l

47 l-4 l

UTS

+10.67 l

l i

l 47 l

4 l

UTS

+12.04 l

l l

48 l

21 l

UTS

+2.89 l

{

l 48 l

24 l

UTS

+5.60 l

l 48 l

112 l

UTS

+5.39 l

l 48 l

114 l

UfS

+0.95 l

l 49 l

5 l

UTE

-5.44 l

l 51 l

21 l

UTS

+12.19 l

l 51 l

114 l

UTS

+5.28 l

l 51 l

116 l

UTS

+5.46 l

l 51 l

116 l

UTS

+8.91 l

l 51 l

119 l

UTS

+8.84 l

l 52 l

125 l

UTS

+8.16 l

l 53 l

68 l

UTS

+10.19 l

l 53 l

97 l

UTS

+5.45 l

l 53 l

109 l

UTS

+4.86 l

l 53 l

109 l

UTS

+9.52 l

l 53 l

109 l

UTS

+9.73 l

l 55 l

12 l

UTE

-7.97 l

l 55 l

123 l

UTS

+8.45 l

l 55 l

123 l

UTS

+11.11 l

i l

55 l

124 l

UTS

+7.32 l

l l

55 l

124 l

UTS

+10.31 l

l l

56 l

3 l

UTS

+7.25 l

l l

56 l

3 l

UTS

+9.69 l

l 56 l

23 l

UTS

+11.83 l

Attachment ts 1CAN069806 Page 11 of127 Table 5 (cont)

"A" OTSG Upper Tubesheet Volumetric Indications l

56 l

125 l

UTS

+7.%

l l

56 l

125 l

UTS

+8.49 l

l 56 l

127 l

UTS

+8.57 l

l 57 l

12 l

UTS

+6.11 l

l l

57 l

123 l

UTS

+8.22 l

l l

57 l

126 l

UTS

+4.50 l

l 58 l

26 l

UTS

+8.49 l

l 58 l

26 l

UTS

+12.28 l

l l

58 l

103 l

UTS

+13.09 l

l l

59 l

5 l

UTE

-4.25 l

l l

59 l

8 l

UTS

+11.88 l

l 59 l

17 l

UTS

+9.80 l

l 59 l

113 l

UTS

+11.18 l

l 60 l

2 l

UTS

+7.52 l

l 60 l

121 l

UTS

+9.95 l

i l

60 l

124 l

UTS

+10.27 l

l l

61 l

40 l

UTS

+7.92 l

l 61 l

111 l

UTS

+4.25 l

l 62 l

99 l

UTS

+3.90 l

l 63 l

61 l

UTS

+19.41 l

l l

64 l

22 l

UTS

+4.55 l

l 64 l

53 l

UTS

+11.13 l

l 65 l

6 l

UTE

-2.31 l

l l

65 l

47 l

UTS

+6.68 l

l l

65 l

56 l

UTS

+11.23 l

l 65 l

56 l

UTS

+12.29 l

l 65 l

57 l

UTS

+5.64 l

l 65 l

63 l

UTS

+17.35 l

l l

65 l

120 l

UTS

+9.28 l

l 66 l

12 l

UTS

+6.70 l

l l

66 l

12 l

UTS

+17.00 l

l l

66 l

43 l

UTS

+10.07 l

l 66 l

123 l

UTS

+8.03 l

l 66 l

127 l

UTS

+5.52 l

l l

66 l

127 l

UTS

+6.90 l

l 67 l

10 l

UTS

+10.90 l

l 67 l

10 l

UTS

+13.09 l

l 67 l

25 l

UTS

+8.00 l

l

Attachment to ICAN069806 Page 12 of 127 l

Table 5 (cont) j "A" OTSG Upper Tubesheet Volumetric Indications i

l 67 l

120 l

UTS

+4.77 l

l 68 l

8 l

UTS

+10.64 _j l

l 68 l

9 l

UTS

+7.83 l

l 68 l

16 l

UTS

+12.18 l

l 68 l

17 l

UTS

+12.52 l

l 68 l

26 l

UTS

+6.73 l

68 l

36 l

UTE

-11.74 l

l 68 l

59 l

UTS

+6.07 l

68 l

130 l

UTS

+5.84 l

69 l

16 l

UTS

+3.56 l

1 l

69 l

20 l

UTS

+15.07 l

l 69 l

22 l

UTS

+8.31 l

69 l

30 l

UTS

+11.92 l

69 l

39 l

UTS

+14.66 l

69 l

40 l

UTE

-4.12 l

l 69 l

40 l

UTE

-13.71 l

69 l

54 l

UTE

-5.80 l

69 l

54 l

UTE

-10.27 l

69 l

74 l

UTS

+18.57 l

69 l

117 l

UTS

+6.16 l

l 70 l

11 l

UTE

-9.32 l

l 70 l

19 l

UTS

+14.89 l

70 l

21 l

UTS

+8.74 l

70 l

21 l

UTS

+20.38 l

70 l

65 l

UTS

+15.26 l

70 l

120 l

UTS

+9.70 l

71 l

19 l

UTS

+6.83 l

71 l

19 l

UTS

+10.10 l

71 l

32 l

UTS

+7.46 l

71 l

45 l

UTS

+7.19 l

71 l

57 l

UTS

+0.75 l

72 l

56 l

UTS

+5.05 l

l 72 l

106 l

UTS

+13.22 l

l 73 l

65 l

UTS

+17.47 l

74 l

64 l

UTS

+0.68 l

76 l

78 l

UTS

+20.13 l

78 l

34 l

UTS

+6.3 8 l

78 l

46 l

UTS

+0.88 l

t

Attachment to 1CAN069806 Page 13 of127 Table 5 (cont)

"A" OTSG Upper Tubesheet Volumetric Indications l

79 l

14 l

UTE

-2.87 l

l 79 l

18 l

UTS

+4.75 l

79 l

26 l

UTE

-2.44 l

79 l

65 l

UTS

+14.30 l

79 l

74 l

UTS

+20.10 l

l 79 l

123 l

UTS

+6.37 l

80 l

14 l

UTS

+4.56 i

l 80 l

14 l

UTS

+10.26 l

80 l

64 l

UTS

+21.19 l

81 l

17 l

UTS

+17.28 l

81 l

25 l

UTS

+18.29 l

81 l

48 l

UTS

+0.31 l

l 81 l

55 l

UTS

+11.83 l

81 l

55 l

UTS

+12.07 I

l 81 l

55 l

UTS

+13.07 I

l 81 l

55 l

UTS

+16.01

)

l 81 l

56 l

UTS

+11.12 l

l 81 l

56 l

UTS

+15.53 l

l 81 l

57 l

UTS

+9.90 l

l 82 l

23 l

UTS

+17.54 1

l 82 l

27 l

UTS

+7.16 l

82 l

31 l

UTS

+17.44 l

l 82 l

32 l

UTS

+5.98

)

l 82 l

34 l

UTS

+8.66 j

l 82 l

37 l

UTS

+12.12 l

82 l

55 l

UTS

+12.37 l

82 l

67 l

UTS

+13.85 l

83 l

17 l

UTS

+0.44 l

83 l

39 l

UTE

-3.39 l

83 l

48 1

UTS

+16.47 l

83 l

50 l

UTS

+22.00 l

83 l

51 l

UTS

+11.51 l

83 l

130 l

UTS

+5.95 l

84 l

35 l

UTS

+12.87 l

84 l

45 l

UTS

+16.75 l

85 l

13 l

UTS

+7.27 l

85 l

26 l

UTS

+8.48 l

85 l

43 l

UTS

+19.21

Attachment to 1CAN069806 Page 14 of127 Table 5 (cont)

"A" OTSG Upper Tubesheet Volumetric Indications

+21.62 85 l

53 l

UTS

+ 17.02 85 l

53 l

UTS

+17.68 86 l

16 l

UTS

+5.50 86 l

32 l

UTS

+12.06 86 l

34 l

UTS

+8.85 86 l

75 l

UTS

+4.53 86 l

113 l

UTS

+20.99 86 l

113 l

UTS

+22.20 86 l

130 l

UTS

+3.24 87 l

12 l

UTS

+6.12 88 l

59 l

UTS

+15.01

{

89 l

52 l

UTS

+19.19 90 l

3 l

UTS

+ 1.08 90 l

17 l

UTS

+8.49 91 l

2 l

UTS

+ 1.04 91 l

56 l

UTS

+15.04 91 l

56 l

UTS

+16.40 92 l

2 l

UTS

+0.85 92 l

4 l

UTS

+7.39 92 l

4 l

UTS

+17.33 92 l

4 l

UTS

+17.40 92 l

4 l

UTS

+17.89 i

92 l

11 l

UTS

+0.79 92 l

109 l

UTS

+4.62 92 l

119 l

UTS

+7.38 92 l

127 l

UTS

+6.57 94 l

2 l

UTS

+ 1.09 94 l

2 l

UTS

+6.41 94 l

5 l

UTS

+12.80 94 l

58 l

UTS

+18.67 94 l

121 l

UTS

+6.33 95 l

30 l

UTS

+13.48 96 l

7 l

UTS

+10.47 96 l

25 l

UTS

+8.68 97 l

109 l

UTS

+3.31 97 l

119 l

UTS

+4.08 98 l

6 l

UTS

+6.21 l

98 l

123 l

UTS

+8.29

Attachment to ICAN069806 Page 15 of127 4

Table 5 (cont) l "A" OTSG Upper Tubesheet Volumetric Indications l

l 99 l

121 l

UTS

+10.83 l

l 99 l

123 l

UTS

+10.74 l

l 100 l

110 l

UTS

+4.56 l

j l

101 l

112 l

UTS

+10.13 l

l 101 l

121 l

UTS

+13.39 l

l l

102 l

2 l

UTS

+11.54 l

l 102 l

2 l

UTS

+12.88 l

l l

102 l

14 l

UTS

+10.06 l

l l

102 l

66 l

UTS

+20.%

l 1

l 102 l

112 l

UTS

+12.54 l

l l

103 l

8 l

UTS

+10.80 l

l 104 l

14 l

UTS

+8.76 l

l 104 l

15 l

UTS

+9.02 l

l 104 l

15 l

UTS

+12.54 l

l 105 l

3 l

UTS

+9.34 l

l l

105 l

3 l

UTS

+14.68 l

l l

105 l

9 l

UTS

+5.77 l

l l

105 l

112 l

UTS

+8.87 l

l 107 l

14 l

UTS

+6.48 l

l 107 l

14 l

UTS

+13.33 l

l 108 l

99 l

UTS

+4.54 l

l 111 l

107 l

UTS

+7.66 l

l 111 l

109 l

UTS

+5.15 l

l 114 l

2 l

UTS

+3.73 l

l 114 l

94 l

UTS

+3.62 l

l 114 l

113 l

UTS

+10.90 l

l l

115 l

108 l

UTS

+10.79 l

l 115 l

113 l

UTS

+9.19 l

l l

115 l

114 l

UTS

+1.30 l

l 116 l

72 l

UTS

+15.10 l

l l

116 l

98 l

UTS

+17.71 l

l 116 l

104 l

UTS

+5.05 l

i l

l 116 l

106 l

UTS

+7.37 l

l 117 l

13 l

UTS

+9.24 l

l 117 l

16 l

UTS

+6.55 l

l 117 l

66 l

UTS

+18.71 l

l 117 l

99 l

UTS

+3.91 l

l 118 l

15 l

UTS

+12.71 l

l l

Attachment to 1CAN069806 Page 16 of127 Table 5 (cont)

"A" OTSG Upper Tubesheet Volumetric Indications I

62 l

119 l

3 l

UTS

+8.04 4

l 119 l

105 l

UTS

+5.50 l

120 l

92 l

UTS

+6.56 l

120 l

99 l

UTS

+7.85 l

120 l

105 l

UTS

+5.30 l

120 l

106 l

UTS

+3.71 l

120 l

106 l

UTS

+4.80 l

121 l

72 l

UTS

+15.39 l

122 l

98 l

UTS

+9.3 5 I

l 122 l

104 l

UTS

+3.94 l

123 l

100 l

UTS

+6.83 l

124 l

12 l

UTS

+12.50 l

l 125 l

90 l

UTS

+11.40 l

125 l

98 l

UTS

+10.03 l

126 l

96 l

UTS

+9.34 l

126 l

99 l

UTS

+7.30 l

126 l

99 l

UTS

+8.27 l

126 l

99 l

UTS

+8.28 l

127 l

27 l

UTS

+3.74 l

127 l

67 l

UTS

+17.79 l

129 l

91 l

UTS

+8.38 l

130 l

3 l

UTS

+11.51 l

132 l

29 l

UTS

+7.3 5 l

132 l

80 l

UTS

+10.79 l

134 l

3 l

UTS

+7.41 l

134 l

31 l

UTS

+9.82 l

134 l

37 l

UTS

+13.88 l

136 l

33 l

UTS

+12.65 l

136 l

76 l

UTS

+12.43 l

137 l

3 l

UTS

+6.83 l

137 l

12 l

UTS

+7.81 l

138 l

25 l

UTS

+11.40 l

138 l

31 l

UTS

+5.54 l

138 l

40 l

UTS

+10.30 l

138 l

72 l

UTS

+7.30 l

l 139 l

31 l

UTS

+6.3 3 l

l 139 l

51 l

UTS

+8.19 l

139 l

52 l

UTS

+6.57 l

I Attachment to 1CANM9806 Page 17 of127 Table 5 (cont)

"A" OTSG Upper Tubesheet Volumetric Indications l

142 l

49 l

UTS

+6.75 l

142 l

49 l

UTS

+7.53 l

143 l

38 l

UTS

+11.03 l

l 145 l

24 l

UTS

+7.3 8 l

145 l

24 l

UTS

+7.44 l

146 l

48 l

UTS

+8.15 l

147 l

37 l

UTS

+14.53 l

l 148 l

6 l

UTS

+7.49 1

l l

l l

l l

l l

1

Attechment to 1CAN069806 Pege 18 of127 Table 6 "B" OTSG Upper Tubesheet Volumetric Indications 26 l

18 l

UTS

+5.53 l

29 l

102 l

UTS

+6.00 l

29 l

102 l

UTS

+6.17 l

37 l

114 l

UTS

+21.92 l

47 l

6 l

UTS

+2.33 l

48 l

7 l

UTS

+4.40 l

50 l

1 l

UTS

+9.78 l

50 l

2 l

UTS

+4.29 l

50 l

2 l

UTS

+5.14 l

50 l

2 l

UTS

+9.52 l

50 l

2 l

UTS

+9.74 l

52 l

102 l

UTS

+3.12 l

52 l

122 l

UTS

+2.92 l

53 l

3 l

UTS

+6.31 l

53 l

3 l

UTS

+7.46 l

53 l

5 l

UTS

+5.59 l

54 l

2 l

UTS

+4.12 l

54 l

106 l

UTS

+4.41 l

55 l

2 l

UTS

+2.61 l

55 l

2 l

UTS

+3.25 l

55 l

2 l

UTS

+5.13 l

55 l

3 l

UTS

+6.64 l

55 l

8 l

UTS

+6.42 l

55 l

8 l

UTS

+6.78 l

56 l

9 l

UTS

+4.66 l

58 l

41 l

UTS

+4.67 l

58 l

87 l

UTS

+7.07 l

59 l

115 l

UTS

+9.36 l

60 l

9 l

UTS

+4.45 l

60 l

96 l

UTS

+5.56 l

60 l

113 l

UTS

+4.33 l

62 l

4 l

UTS

+5.92 l

64 l

6 l

UTS

+6.73 l

64 l

8 l

UTS

+5.99 l

64 l

51 l

UTS

+4.85 l

68 l

23 l

UTS

+7.31 l

68 l

25 l

UTS

+2.75 l

69 l

11 l

UTS

+4.93 l

Attachment to =

l ICAN069806 l

Page 19 of127 Table 6 (cost)

"B" OTSG Upper Tubesheet Volumetric Indications l

69 l

40 l

UTS

+5.58 l

l 69 l

41 l

UTS

+5.33 l

l 69 l

51 l

UTS

+7.34 l

l 70 l

19 l

UTS

+3.03 l

l 71 l

15 l

UTS

+4.72 l

l l

71 l

15 l

UTS

+7.00 l

l l

71 l

18 l

UTS

+5.41 l

l 71 l

28 l

UTS

+3.30 l

l 71 l

50 l

UTS

+12.24 l

l 72 l

14 l

UTS

+3.31 l

l 72 l

23 l

UTS

+4.46 l

l l

72 l

27 l

UTS

+4.95 l

l 72 l

43 l

UTS

+2.34 l

l 72 l

43 l

UTS

+4.09 l

l 72 l

56 l

UTS

+5.31 l

l 73 l

25 l

UTS

+4.86 l

l 73 l

51 l

UTS

+7.23 l

l 73 l

93 l

UTS

+21.33 l

l 73 l

93 l

UTS

+21.68 l

l 74 l

58 l

UTS

+3.38 l

l 74 l

58 l

UTS

+4.45 l

l 75 l

37 l

UTS

+4.87 l

l 75 l

44 l

UTS

+5.33 l

l 77 l

66 l

UTS

+4.29 l

l 78 l

37 l

UTS

+8.81 l

l l

78 l

44 l

UTS

+3.92 l

l l

78 l

58 l

UTS

+3.44 l

l 78 l

63 l

UTS

+5.88 l

l 78 l

68 UTS

+4.%

l l

78 l

69 UTS

+2.10 l

l 79 l

24 UTS

+18.43 l

l 79 l

24 UFS

+19.16 l

l 79 l

32 UTS

+5.25 l

l 79 l

35 UTS

+4.29 l

l 79 l

53 UTS

+6.21 l

l 79 l

57 UTS

+6.11 l

l 80 l

22 UTS

+4.21 l

l 80 l

22 UTS

+4.92 l

L l

Attachment to 1CAN069806 Page 20 of 127 Table 6 (cont)

"B" OTSG Upper Tubesbeet Voluaietric Indications l

80 l

28 l

UTS

+8.95 l

l 80 l

53 l

UTS

+11.51 l

l 80 l

101 l

UTS

+21.83 l

l 80 l

101 l

UTS

+23.17 l

l 82 l

17 l

UTS

+0.32 l

l 82 l

17 l

UTS

+3.27 l

l 82 l

26 l

UTS

+3.61 l

l 82 l

45 l

UTS

+7.36 l

l l

82 l

56 l

UTS

+9.12 l

l 82 l

58 l

UTS

+8.30 l

l 83 l

14 l

UTS

+5.06 l

l 83 l

14 l

UTS

+11.15 l

l 83 l

14 l

UTS

+14.64 l

l 83 l

17 l

UTS

+2.65 l

l 83 l

38 l

UTS

+7.91 l

l l

84 l

20 l

UTS

+19.85 l

l l

84 l

20 l

UTS

+21.33 l

l l

84 l

30 l

UTS

+4.98 l

l 84 l

30 l

UTS

+6.18 l

l l

84 l

35 l

UTS

+0.41 l

l l

85 l

14 l

UTS

+3.43 l

l l

85 l

16 l

UTS

+3.78 l

l 85 l

18 l

UTS

+3.61 l

l 85 l

18 l

UTS

+4.73 l

l 85 l

19 l

UTS

+20.77 l

l l

85 l

21 l

UTS

+12.21 l

l l

85 l

45 l

UTS

+6.28 l

l l

85 l

45 l

UTS

+8.22 l

l 86 l

25 l

UTS

+4.61 l

l 86 l

25 l

UTS

+6.59 l

l 87 l

5 l

UTS

+5.19 l

l 87 l

25 l

UTS

+7.69 l

l 87 l

25 l

UTS

+8.40 l

l 87 l

61 l

UTS

+4.81 l

l 88 l

15 l

UTS

+12.76 l

l 89 l

10 l

UTS

+6.21 l

l 89 l

12 l

UTS

+0.64 l

l 89 l

110 l

UTS

+21.31 l

Attachmerd to 1CAN069806 Page 21 of127 Table 6 (ccat)

"B" OTSG Upper Tubesheet Volumetric Indications l

89 l

110 l

UTS

+22.72 l

l 92 l

10 l

UTS

+4.79 l

l 93 l

5 l

UTS

+5.02 l

f l

93 l

5 l

UTS

+5.92 l

l l

95 l

68 l

UTS

+20.60 l

l l

1 l

UTS

+4.88 l

l l

1 l

UTS

+5.41 l

l l

8 l

UTS

+6.56 l

l l

14 l

UTS

+5.76 l

l l

18 l

UTS

+6.11 l

l l

l 22 l

UTS

+4.86 l

l l

22 l

UTS

+5.43 l

l l

34 l

UTS

+4.14 l

l 98 l

9 l

UTS

+6.07 l

l 98 l

9 l

UTS

+6.68 l

l 100 l

5 l

UTS

+7.18 l

l 100 l

11 l

UTS

+7.08 l

l 101 l

10 l

UTS

+6.92 l

l 101 l

10 l

UTS

+7.03

.l

'l 102 l

9 l

UTS

+5.69 l

l 103 l

17 l

UTS

+6.80 l

l 103 l

19 l

UTS

+5.12 l

l 103 l

22 l

UTS

+7.01 l

l 104 l

2 l

UTS

+4.33 l

l l

106 l

17 l

UTS

+5.79 l

l 106 l

74 UTS

+20.03 l

l 107 l

9 UTS

+3.37 l

l 107 l

73 UTS

+22.03 l

l l

109 l

117 UTS

+6.80 l

l 110 l

2 UTS

+6.41 l

l 111 l

115 UTS

+5.10 l

l 116 l

2 UTS

+7.48 l

l 116 l

13 UTS

+4.98 l

l 117 l

3 UTS

+5.31 l

l 117 l

4 UTS

+5.62 l

l 117 l

4 UTS

+6.03 l

l 117 l

5 UTS

+4.91 l

l 118 l

3 UTS

+4.60 l

Attachment to 1CAN069806 Page 22 of127 Table 6 (cont)

"B" OTSG Upper Tubesheet Volumetric Indications l

118 l

3 l

UTS

+5.89 l

l 119 l

4 l

UTS

+5.10 l

l 121 l

4 l

UTS

+4.59 l

l 122 l

1 l

UTS

+3.20 l

l 123 l

8 l

UTS

+8.69 l

l 125 l

5 l

UTS

+7.98 l

l 126 l

8 l

UTS

+4.08 l

l 131 l

7 l

UTS

+4.12 l

l 131 l

7 l

UTS

+5.09 j

l 137 l

6 l

UTS

+6.30 l

l 137 l

22 l

UTS

+4.27 l

[

144 l

18 l

UTS

+5.35 l

l 145 l

11 l

UrS

+5.96 l

l 146 l

38 l

UTS

+4.59 l

l 149 l

13 l

UTS

+4.40 l

[

150 l

18 l

UTS

+6.10 l

Attachment to 1CAN069806 Page 23 of 127 Table 7 "A" OTSG Upper Roll Area Flaw 5

UTE

-1.72 1

6 l

MAI l

_0.44 UTE

-1.53 1

8 l

SEA l

1.09 UTE

-0.36 1

9 l

MAI l

0.29 UTE

-1.53 2

1 l

SEA l

7.00 UTE

-0.27 2

4 l

SEA l

1.36 UTE

-0.20 l

2 5

l SEA l

2.74 UTE

-0.22 3

2 l

SEA l

2.47 UTE

-0.25 3

3 l

SEA l

3.61 UTE

-0.22 3

17 l

SEA l

1.58 UTE

-0.17 3

19 l

SEA l

0.99 UTE

-0.17 3

31 l

SEA l

1.13 UTE

-0.25 4

1 l

SEA l

2.77 UTE

-0.30 4

6 l

SEA l

0.78 UTE

-0.25 4

9 l

SEA l

1.62 UTE

-0.25 4

15 l

MEA l

1.51 UTE

-0.26 4

29 l

SAI l

0.38 UTE

-1.94 l

4 34 l

MEA l

2.48 UTE

-0.30 4

35 l

SEA l

0.67 UTE

-0.28 l

4 36 l

MEA l

2.41 UTE

-0.32 5

3 l

SEA l

1.49 UTE

-0.15 5

7 l

SEA l

1.11 UTE

.-0.18 5

8 l

MEA l

2.20 UTE

-0.25 i

5 9

l MEA l

0.89 UTE

-0.17 5

11 l

MEA l

1.07 UTE

-0.15 s

5 11 l

SAI l

1 UTE

-1.79 l

5 18 l

MEA l

2.01 UTE

-0.26 5

19 l

MEA l

0.84 UTE

-0.25 5

21

'l SEA l

1.19 UTE

-0.17 5

22 l

MEA l

2.04 UTE

-0.23 5

23 l

SEA l

0.79 UTE

-0.17 6

3 l

MEA l

2.26 UTE

-0.19 6

6 l

MEA l

1.59 UTE

-0.29 l

6 12 l

MEA l

3.66 UTE

-0.18 6

14 l

SEA l

1.73 UTE

-0.14 6

20 l

MEA l

1.27 UTE

-0.09 6

22 l

SEA l

0.75 UTE

-0. ' 4 6

24 l

SEA l

1.55 UTE

-0.17 6

24 l

SAI l

0.95 UTE

-1.84 i

l I

Attachment to ICAN069806 Page 24 of127 l

Table 7 (cont)

{

"A" OTSG Upper Roll Area Fisws l

g,q
ll 1.E.g
. /-

.. ;.0 4 XgyW ;;i.;Migy9Mg;;.

j 6

39 AEA 2.15 UTE

-0.32 6

41 AEA 1.56 UTE

-0.27 l

6 42 NEA 2.22 UTE

-0.29 7

11 hEA 1.65 UTE

-0.20 l

7 12 SEA 1.71 UTE

-0.17 7

13 SEA 1.16 UTE

-0.22

{

7 14 SEA 2.02 UTE

-0.28 l

l 7

23 MEA 1.99 UTE

-0.53 7

35 SEA 1.56 UTE

-0.16 7

41 SEA 1.54 UTE

-0.36 7

42 SEA 1.44 UTE

-0.34 8

9 hEA 1.11 UTE

-0.34 8

11 SEA 1.39 UTE

-0.25 8

15 SAI 0.37 UTE

-1.71 8

17 SAI 0.67 UTE

-1.91 8

24 SEA 1.51 UTE

-0.33 8

25 SEA 1.80 UTE

-0.21 8

31 SEA 1.83 UTE

-0.21 8

31 SAI 0.37 UTE

-2.02 8

42 SEA 0.85 UTE

-0.31 8

43 SEA 0.93 UTE

-0.09 8

53 MEA 0.87 UTE

-0.28 8

54 SEA 1.25 UTE

-0.24 9

6 SEA 0.96 UTE

-0.30 9

16 SEA 2.02 UTE

-0.27 9

18 MEA 1.85 UTE

-0.26 9

19 SEA 1.77 UTE

-0.31 0

26 SEA 0.86 UTE

-0.25 9

27 hEA 2.49 UTE

-0.27 9

33 SEA 1.75 UTE

-0.33 9

34 MEA 2.56 UTE

-0.27 9

45 SEA 0.68 UTE

-0.27 9

47 MEA 1.51 UTE

-0.27 9

55 MEA 1.76 UTE

-0.32 9

57 SEA 0.86 UTE

-0.34 9

62 SEA 2.14 UTE

-0.31 10 1

MEA 3.08 UTE

-0.30 10 9

SEA 1.69 UTE

-0.23 10 10 SEA 1.14 UTE

-0.21 l

Attachment to 1CAN069806 Page 25 of127 Table 7 (cont)

"A" OTSG Upper Roll Area Flaws

~.

.Y "'

l 10 l

13 SEA 3.90 UTE

-0.30 l

10 l

16 MEA 2.79 UTE

-0.21 l

10 l

18 MEA 1.59 UTE

-0.20 l

10 l

19 SEA 1.48 UTE

-0.21 l

10 l

20 SEA 0.99 UTE

-0.22 l

10 l

27 SEA 6.77 UTE

-0.08 l

10 l

28 MEA 1.44 UTE

-0.24 l

10 l

33 MEA 2.19 UTE

-0.26 l

10 l

34 SEA 2.88 UTE

-0.24 l

10 l

48 SEA 0.59 UTE

-0.27 l

10 l

57 SEA 0.76 UTE

-0.32 l

10 l

65 SEA 1.15 UTE

-0.31 l

11 l

2 SEA 2.1 I UTE

-0.21 l

11 1

5 MEA 2.12 UTE

-0.28 l

11 l

6 MEA 1.81 UTE

-0.21 l

11 l

13 MEA 2.51 UTE

-0.21 l

11 l

14 MEA 2.95 UTE

-0.25 l

11 l

15 SEA 2.30 UTE

-0.16 l

11 l

15 sal 4.15 UTE

-2.26 l

11 l

17 MEA 1.60 UTE

-0.30 l

11 l

20 MEA 1.92 UTE

-0.24 l

11 l

21 MEA 1.37 UTE

-0.25 l

11 l

22 SEA 2.22 UTE

-0.28 l

11 l

28 SEA 2.66 UTE

-0.19 l

11 l

29 sal 0.59 UTE

-2.77 l

11 l

32 SEA 1.43 UTE

-0.22 l

11 l

34 MEA 2.13 UTE

-0.24 l

11 l

36 SEA 4.81 UTE

-0.30 l

11 l

37 SEA 3.36 UTE

-0.30 l

11 l

48 SEA 1.78 UTE

-0.37 l

11 l

58 SEA 1.20 UTE

-0.34 l

12 l

4 SEA 1.43 UTE

-0.21 l

12 l

7 SEA 1.32 UTE

-0.21 l

12 l

17 SEA 2.68 UTE

-0.19 l

12 l

18 SEA 1.62 UTE

-0.17 l

12 l

19 MEA 2.32 UTE

-0.34 l

12 l

22 MEA 2.09 UTE

-0.16 l

12 l

23 MEA 2.69 UTE

-0.31

_ A"aa w to 1CAN069806 Page 26 of127 Table 7 (cost)

"A" OTSG Upper Roll Area Flaws 12 l

24 l

SAI l

1.4 l UTE

-1.33 12 l

30 l

SEA l

2.30 l UTE

-0.19 l

12 l

33 l

hEA l

2.05 l UTE

-0.15 12 l

36 l

SEA l

2.44 l UTE

-0.16 12 l

37 l

SEA l

2.36 l UTE

-0.16 12 l

38 l

SEA l

0.68 l UTE

-0.28 12 l

39 l

SEA l

2.42 l UTE

-0.18 12 l

58 l

MEA l

1.20 l UTE

-0.32 12 l

63 l

SEA l

1.74 l UTE

-0.23 12 I

71 l

SEA l

1.33 l UTE

-0.28 13 l

9 l

SEA l

0.93 l UTE

-0.22 l

13 l

13 l

SEA l

1.21 l UTE

-0.35 13 l

17 l

MEA l

2.28 l UTE

-0.25 13 l

18 l

MEA l

2_.42 l UTE

-0.41 13 l

22 l

MEA l

1.41 l UTE

-0.16 13 l

25 l

MEA l

2.10 1 UTE

-0.23 13 l

32 l

MEA l

1.25 l UTE

-0.20 13 l

33 l

MEA l

0.86 l UTE

-0.25 13 l

34 l

SEA l

1.09 l UTE

-0.11 13 l

39 l

MEA l

1.85 l UTE

-0.35 13 l

40 l

SEA l

0.56 l UTE

-0.19 13 l

50 l

SAI l

0.48 l UTE

-1.54 13 l

51 l

SEA l

1.65 l UTE

-0.28 13 l

63-l SEA l

1.57 l UTE

-0.35 13

'l 73 l

SEA l

1.16 l UTE

-0.17 14 l

1 l

SEA l

1.02 l UTE

-0.33 14 l

3 l

SEA l

1.17 l UTE

-0.26 14 l

5 l

SEA l

0.72 l UTE

-0.27 14 l

17 l

SEA l

1.03 l UTE

-0.18 14 l

19-l MEA l

2.56 l UTE

-0.12

~

14 l

24 l

SEA l

1.27 l UTE

-0.16 l

14 l

37 l

MEA l

0.97 l UTE

-0.16 I

14 l

41 l

MAI l

0.89 l UTE

-1.92 l

14 l

48 l

SEA l

1.17 l UTE

-0.53 14 1

49 l

MEA l

1.23-1 UTE

-0.27 14 l

53 l

MEA l

1.37 l UTE

-0.24 14 l

64 l

MEA l

2.65 l UTE

-0.44 15 l

4 l

SEA l

0.64 l UTE

-0.28

Attachment to ICAN069806 Page 27 of127 Table 7 (cont)

"A" OTSG Upper Roll Area Flaws 5

l 15 l

10 SEA l

2.52 l UTE

-0.22 l

15 l

11 SEA l

1.78 l UTE

-0.13 l

15 l

18 MEA l

1.78 l UTE

-0.22 l

15 l

19 SEA l

1.00 l UTE

-0.12 l

15 l

26 SAI l

1.25 l UTE

-2.14 l

15 l

27 SEA l

1 09 l UTE

-0.15 l

15 l

33 MEA l

1.25 l UTE

-0.15 l

15 l

35 MEA l

1.35 l UTE

-0.20 l

15 l

39 SAI l

0.47 l UTE

-1.58 l

15 l

64 SEA l

2.30 l UTE

-0.52 l

15 l

65 SEA l

0.71 l UTE

-0.30 l

16 l

1 SEA l

3.42 l UTE

-0.26 l

16 l

2 SEA l

0.97 l UTE

-0.15 l

16 l

29 SAI l

1.37 l UTE

-1.71 l

16 l

35 SEA l

1.11 l UTE

-0.17 l

16 l

37 SEA I

1.56 l UTE

-0.17 l

16 l

37 SAI l

0.7 l UTE

-1.45 l

16 l

67 SEA l

1.14 l UTE

-0.29 l

16 l

68 SEA l

1.50 l UTE

-0.25 l

17 l

1 MEA l

2.47 l UTE

-0.16 l

17 l

6 MEA l

0.81 l UTE

-0.12 l

17 l

20 MEA l

1.60 l UTE

-0.17 l

17 l

28 SAI l

1.66 l UTE

-1.93 l

17 l

35 SEA l

2.09 I UTE

-0.29 l

17 l

37 SAI l

0.61 UTE

-3.04 l

17 l

55 SAI l

0.26 UTE

-1.58 l

17 l

66 SEA l

0.89 UTE

-0.28 l

18 l

2 SEA l

1.34 UTE

-0.13 l

18 l

6 SEA l

0.77 UTE

-0.11 l

18 l

7 SEA l

0.70 UTE

-0.24 l

18 l

8 SEA l

1.05 UTE

-0.16 l

18 l

10 SEA l

0.69 UTE

-0.13 l

18 l

11 SEA l

0.82 UTE

-0.28 l

18 l

24 MEA 1.48 UTE

-0.10 l

18 l

25 SEA l

0.79 UTE

-0.30 l

18 l

29 MEA l

1.43 UTE

-0.12 l

18 l

29 hEA l

1.00 UTE

-0.52 l

18 l

37 SEA l

1.21 UTE

-0.08 l

1

l Table 7 (cont)

"A" OTSG Upper Roll Area Flaws

.. ~.

18 42 SEA l

4.22 UTE

-0.21 18 69 SEA l

0.77 UTE

-0.26 18 77 SEA l

0.47 UTE

-0.21 19 1

MEA l

0.71 UTE

-0.28 19 4

SEA l

0.55 UTE

-0.26 19 5

MEA l

1.28 UTE

-0.15 19 7

MEA l

1.21 UTE

-0.18 19 8

SEA l

1.01 UTE

-0.34 19 9

MEA l

1.39 UTE

-0.15 19 11 SEA l

1.94 UTE

-0.14 19 13 MEA l

1.70 UTE

-0.14 19 15 MEA l

0.95 UTE

-0.11 19 19 SEA l

1.55 UTE

-0.14 19 20 SEA l

0.61 UTE

-0.19 19 21 MEA l

1.43 UTE

-0.13 19 24 MEA l

0.92 UTE

-0.16 19 43 MEA l

1.23 UTE

-0.24 20 5

SEA l

1.94 UTE

-0.18 20 7

SEA l

1.51 UTE

-0.17 20 12 SEA l

1.07 UTE

-0.07 20 22 SEA l

1.06 UTE

-0.17 20 23 SEA l

1.13 UTE

-0.20 20 31 MEA l

0.40 UTE

-0.13 20 37 SEA l

1.13 UTE

-0.10 20 38 SEA l

1.03 UTE

-0.13 20 42 SEA l

1.18 UTE

-0.09 20 66 SEA l

0.81 UTE

-0.61 20 68 SEA l

1.38 UTE

-0.63 20 71 SEA l

1.26 UTE

-0.30 21 2

SEA l

1.22 UTE

-0.15 21 4

MEA l

1.56 UTE

-0.18 21 5

SEA l

1.51 UTE

-0.10 21 6

SEA l

2.02 UTE

-0.17 21 7

SEA l

1.28 UTE

-0.28 21 22 MEA l

1.44 UTE

-0.21 21 24 SAI l

0.8 UTE

-1.92 21 25 MEA l

1.37 UTE

-0.16

.21 32 SEA l

1.31 UTE

-0.16 21 39 SEA l

1.52 UTE 0.12

Attachment to 1CAN069806 Pa8e 29 Cf127 Table 7 (cost)

"A" OTSG Upper Roll Area Flaws l

21 l

41 l

SEA l

1.36 l UTE

-0.26 l l

21 l

47 l

MEA l

0.95 l UTE

-0.24 l l

21 l

48 l

SEA l

0.78 l UTE

-0.10 l l

21 l

71 l

SEA l

0.77 l UTE

-0.24 l l

21 l

72 l

SEA l

0.59 l UTE

-0.50 l l

22 l

1 l

SAI l

0.9 l UTE

-1.85 l l

22 l

3 l

MAI l

0.73 l UTE

-1.84 l l

22 l

6 l

MEA l

0.86 l UTE

-0.13 l

[

22 l

24 l

MEA l

0.79 l UTE

-0.24 l l

22 l

26 l

SEA l

0.44 l UTE

-0.37 l l

22 l

42 l

SEA l

1.07 l UTE

-0.22 l l

22 l

46 l

SAI l

0.8 l UTE

-1.80 l l

22 l

49 l

SEA l

2.09 l UTE

-0.19 l l

22 l

59 l

SEA l

1.06 l UTE

-0.18 l l

22 l

70 l

MEA l

1.22 l UTE

-0.46 l l

22 l

71 l

SEA.

l 1.27 l UTE

-0.21 l l

22 l

73 l

MEA.

l 1.47 l UTE

-0.20 l

{

l 23 l

1 l

SEA l

1.27 l UTE

-0.30 l l

l 23 l

5 l

SEA l

0.63 l UTE

-0.26 l-l l

23 l

7 l

MEA l

0.67 l UTE

-0.12 l l

23 l

9 l

MEA l

1.78 l UTE

-0.43 l l

23 l

10 l

SEA l

1.77 l UTE

-0.24 l l

23 l

11 l

SEA l

0.74 l UTE

-0.30 l l

23 l

27 l

SEA l

0.99 l UTE

-0.22 l l

23 l

27 l

SEA l

1.36 l UTE

-0.30 l l

23 l

28 l

MEA l

1.99 l UTE

-0.19 l l

23 l

41 l

MEA l

2.24 l UTE

-0.25 l l

23 l

61 l

SEA l

1.19 l UTE

-0.32 l l

23 l

62 l

SEA l

2.57 l UTE

-0.21 l l

l 23 l

72 l

MEA l

1.35 l UTE

-0.25 l l

23 l

73 l

SEA l

1.77 l UTE

-0.26 l l

24 l

1 l

MEA l

1.17 l UTE

-0.22 l l

24 l

2 l

SEA l

0.80 l UTE

-0.19 l l

24 l

4 l

MEA l

1.85 l UTE

-0.29 l l

24 l

8 MEA l

1.72 l UTE

-0.19 l l

24 l

11 MEA l

1.76 l UTE

-0.40 l l

24 l

16 SEA l

1.29 l UTE

-0.29 l l

24 l

18 MEA l

1.62 l UTE

-0.19 l

i Attachment ts 1CAN069806 i

Page 30 of127 Table 7 (comt)

"A" OTSG Upper Roll Area Maws l

24 l

27 l

MEA l

1.43 l UTE

-0.40 l l

24 l

33 l

MEA l

0.75 l UTE

-0.28 l l

24 l

50 l

MEA l

1.20 l UTE

-0.20 l l

24 l

56 l

SEA l

1.22 l UTE

-0.23 l l

24 l

72 l

SEA l

1.30 l UTE

-0.33 l l

25 l

1 l

SEA l

0.91 l UTE

-0.19 l l

25 l

4 l

SEA l

1.73 l UTE

-0.14 l l

25 l

6 l

MEA l

2.42 l UTE

-0.17 l l

25 l

8 l

SEA l

1.49 l UTE

-0.16 l l

25 l

11 l

MEA l

1.83 l UTE

-0.10 l l_

l 25 l

28 l

SEA l

1.58 l UTE

-0.15 l l

l 25 l

29 l

MEA l

2.13 l UTE

-0.28 l l

25 l

30 l

MEA l

2.20 l UTE

-0.19 l l

25 l

36 l

SEA l

1.77 l UTE

-0.14 l l

25 l

43 l

SEA l

1.09 l UTE

-0.16 l l

25 l

82 l

SEA l

1.05 l UTE

-0.27 l l

25 l

98 l

SAI l

0.31 l UTE

-1.18 l l

26 l

5 l

MEA l

1.38 l UTE

-0.12 l l

26 l

6 l

MEA l

1.64 l UTE

-0.18 l l

26 l

9 l

SAI l

0.98 l UTE

-2.21 l l

26 l

10 l

MEA l

2.66 l UTE

-0.14 l l

26 l

16 l

SEA l

1.91 l UTE

-0.20 l l

26 l

61 l

MEA l

1.61 l UTE

-0.40 l l

26 l

99 l

SEA l

0.66 l UTE

-0.36 l l

27 l

4 l

MEA l

1.45 l UTE

-0.16 l l

l 27 l

5 l

MEA l

1.62 lUTE 4.27l l

27 l

6 l

SEA l

1.86 l UTE

-0.15 l l

27 l

8 l

SEA l

2.11 l UTE

-0.19 ]

l l

27 l

9 l

MEA l

0.72 l UTE

-0.13 l l

27 l

10 l

MEA l

2.53 l UTE

-0.17 l l-27 l

13 l

MEA l

1.00 l UTE

-0.11 l l

27 l

14 l

MEA l

1.62 l UTE

-0.16 l l

27 l

16 l

MEA l

1.27 l UTE

-0.17 l l

27 l

18 l

MEA l

1.05 l UTE

-0.16 l i

l 27 l

21 l

MEA l

2.57 l UTE

-0.21 l l

l 27 l

44 l

SEA l

0.80 l UTE

-0.13 l l

27 l

62 l

MAI l

0.46 l UTE

-0.91 l l

l 27 l

74 l

SEA l

2.45 l UTE

-0.17 l 4

Attachment to ICAN069806 Page 31 of127 Table 7 (cont)

"A" OTSG Upper Roll Area Maws l

l 28 l

7 l

MEA l

1.15 l UTE

-0.10 l l

28 l

11 l

MEA l

1.45 l UTE

-0.15 l l

28 l

13 l

MEA l

2.47 l UTE

-0.13 l l

28 l

16 l

MEA l

1.63 l UTE

-0.31 l l

28 l

29 l

SEA l

1.75 l UTE

-0.17 l

]

l 28 l

45 l

MEA l

1.92 l UTE

-0.17 l l

29 l

7 l

MEA l

0.65 l UTE

-0.24 l l

29 l

7 l

SAI l

1.18 l UTE

-1.33 l l

29 l

8 l

SEA l

1.81 l UTE

-0.20 l l

29 l

13 l

SEA l

1.75 l UTE

-0.15 l l

29 l

14 l

MEA l

2.30 l UTE

-0.22 l l

29 l

20 l

MEA l

0.52 l UTE

-0.27 l l

29 l

23 l

SEA l

2.27 l UTE

-0.27 l l

29 l

24 l'

MEA l

0.56 l UTE

-0.25 l l

29 l

98 l

SEA l

0.67 l UTE

-0.42 l l

29 l

103 l

SEA l

1.47 l UTE

-0.33 l l

29 l

104 l

MEA l

1.94 l UTE

-0.24 l l

30 l

6 l

MEA l

1.09 l UTE

-0.16 l l

30 l

7 l

SEA l

0.%

l UTE

-0.29 l l

30 l

11 l

SEA l

0.83 l UTE

-0.24 l l

30 l

12 l

MEA l

1.55 l UTE

-0.19 l l

30 l

15 l

MEA l

1.56 l UTE

-0.25 l l

30 l

15 l

MEA l

1.30 l UTE

-0.27 l l

30 l

17 l

SEA l

1.05 l UTE

-0.27 l l

30 l

18 l

SEA l

2.04 l UTE

-0.24 l l

30 l

31 l

MEA l

1.80 l UTE

-0.29 l l

30 l

35 l

MEA l

1.19 l UTE

-0.22 l l

30 l

35 l

MEA l

1.23 l UTE

-0.27 l l

30 l

36 l

MEA l

0.69 l UTE

-0.28 l l

30 l

79 l

SEA l

0.97 l UTE

-0.32 l l

30 l

102 l

SEA l

0.80 l UTE

-0.24 l l

31 l

5 l

MEA l

0.95 l UTE

-0.18 l l

31 l

6 l

SEA l

2.68 l UTE

-0.34 l l

31 l

8 l

MEA l

1.32 l UTE

-0.15 l l

31 l

9 l

MEA l

2.97 l UTE

-0.35 l l

31 l

10 l

hEA l

1.58 l UTE

-0.15 l l

31 l

11 l

MEA l

1.91 l UTE

-0.31 l l

31 l

12 l

SEA l

2.57 l UTE

-0.35 l

Attachment to 1CAN069806 Page 32 of127 Table 7 (cost)

"A" OTSG Upper rom Area Maws l

31 l

16 l

MEA l

1.23 l UTE

-0.38 l i

l l

31 l

18 l

MEA l

1.38 l UTE

-0.41 l l

31 l

20 l

MEA l

1.59 l UTE

-0.17 l l

31 l

31 l

SAI l

1.16 l UTE

-2.57 l l

31 l

32 l

MEA l

1.26 l UTE

-0.28 l l

31 l

100 l

SEA l

0.77 l UTE

-0.27 l l

31 l

102 l

MEA l

1.83 l UTE

-0.38 l l

31 l

103 l

SEA l

1.49 l UTE

-0.27 l l

31 l

104 l

SEA l

2.06 l UTE

-0.32 l l

31 l

106 l

SEA l

2.35 l UTE

-0.34 l l

32 l

1 l

SEA l

1.64 l UTE

-0.21 l l

32 l

5 l

MEA l

2.29 l UTE

-0.33 l l

l 32 l

8 l

MEA l

2.45 l UTE

-0.16 l l

32 l

9 l

SEA l

1.41 l UTE

-0.39 l l

32 l

10 l

SEA l

1.33 l UTE

-0.17 l l

32 l

12 l

MEA l

2.74 l UTE

-0.15 l l

32 l

13 l

MEA l

2.04 l UTE

-0.38 l l

32 l

15

-l MEA l

2.25 l UTE

-0.52 l l

l 32 l

16 l

MEA l

1.76 l UTE

-0.15 l

)

l 32 l

17 l

MEA l

1.94 l U i'E

-0.49 l l

32 l

18 l

SEA l

2.53 l UTE

-0.17 l l

32 l

21 l

SEA l

0.93 l UTE

-0.23 l l

32 l

31 l

SEA l

1.57 l UTE

-0.21 l l

32 l

32 l

MEA l

1.17 l UTE

-0.21 l l

l 32 l

33 l

SEA l

1.41 l UTE

-0.25 l l

32 l

35 l

MEA l

1.54 l UTE

-0.23 l l

32 l

47 l

MAI l

0.81 l UTE

-2.65 l l

32 l

49 l

MAI l

0.49 l UTE

-2.74 l l

32 l

54 l

SAI l

0.41 l UTE

-2.09 l l

32 l

74 l

SEA l

0.99 l UTE

-0.25 l l

32 l

100 l

MEA l

1.35 l UTE

-0.35 l l

l 32 l

102 l

SEA l

1.07 l UTE

-0.34 l l

32 l

104 l

SEA l

2.56 l UTE

-0.31 l l

l 33 l

1 l

SEA l

0.46 l UTE

-0.23 l l

l 33 l

6 l

MEA l

1.54 l UTE

-0.35 l l

33 l

7 l

SEA l

0.51 l UTE

-0.19 l l

33 l

8 l

MEA l

1.44 l UTE

-0.38 l l

l 33 l

9 l

MEA l

2.38 l UTE

-0.16 l l

Attachment to ICAN069806 Pag)33 of127 Tatde 7 (cost)

"A" OTSG Upper Roll Area Flaws l

33 l

11 l

SEA l

1.06 l UTE

-0.16 l l

33 l

12 l

SEA l

1.02 l UTE

-0.48 l l

33 l

13 l

SEA l

0.71 l UTE

-0.14 l l

33 l

14 l

MEA l

2.38 l UTE

-0.52 l l

33 l

15 l

MEA l

1.06 l UTE

-0.18 l l

33 l

16 l

MEA l

1.99 l UTE

-0.49 l l

33 l

17 l

SEA l

3.06 l UTE

-0.17 l l

33 l

17 l

SAI l

0.33 l UTE

-1.91 l l

33 l

18 l

MEA l

1.04 lUTE

-0.41 l l

33 l

20 l

SEA l

1.02 l UTE

-0.28 l l

33 l

22 l

SEA I

1.65 l UTE

-0.24 l l

33 l

25 l

MEA l

3.24 l UTE

-0.12 l l

33 l

44 l

MEA l

1.78 l UTE

-0.27 l l

33 l

46 l

MEA l

1.43 l UTE

-0.25 l l

33 l

49 l

MEA l

0.82 l UTE

-0.15 l l

33 l

97 l

SEA l

0.%

l UTE

-0.23 l l

33 l

102 l

SEA l

1.38 l UTE

-0.27 l l

33 l

104 l

MEA l

3.69 l UTE

-0.31 l l

33 l

106 l

MEA l

1.49 l UTE

-0.37 l l

34 l

1 l

SEA l-0.91 l UTE

-0.19 l l

34 l

9 l

MEA l

1.79 l UTE

-0.41 l l

34 l

10 l

MEA l

1.58 l UTE

-0.16 l l

34 l

11 l

MEA l

1.03 l UTE

-0.54 l l

34 l

12 l

MEA l

1.82 l UTE

-0.15 l l

34 l

13 l

MEA l

1.47 l UTE

-0.53 l l

l 34 l

15 l

MEA l

2.40 l UTE

-0.17 l l

l 34 l

16 l

MEA l

1.58 l UTE

-0.61 l l

34 l

17 l

SEA l

2.45 l UTE

-0.18 l j

l 34 l

18 l

MEA l

4.03 l UTE

-0.46 l l

l 34 l

19 l

SEA l

1.67 l UTE

-0.15 l l

34 l

21 l

SEA l

1.14 l UTE

-0.14 l l

34 l

31 l

SEA l

1.30 l UTE

-0.21 l l

34 l

37 l

MEA l

1.32 l UTE

-0.28 l l

34 l

48 l

SEA l

4.63 l UTE

-0.34 l l

34 l

49 l

SEA l

0.47 l UTE

-0.26 l l

34 l

50 l

SAI l

0.98 l UTE

-2.45 l l

34 l

57 l

SAI l

0.94 l UTE

-2.14 l l

34 l

60 l

MEA l

1.27 l UTE

-0.42 l

Attachemmt to 1CAN069806 l-Page 34 of127 j

l Tatde 7 (coat)

"A" OTSG Upper Roll Area Flaws l

34 l

77 l

MEA l

0.73 l UTE

-0.21 l l

l 34 l

77 l

MEA l

0.61 l UTE

-0.21 l l

34 l

83 l

SEA l

0.49 l UTE

-0.23 l l

34 l

99 l

SEA l

1.13 l UTE

-0.36 l l

l 34 l

101 l

MEA l

1.80 l UTE

-0.36 l l

l 34 l

103 l

MEA l

1.49 l UTE

-0.37 l l

l 34 l

106 l

SEA l

1.50 l UTE

-0.29 l l

35 l

1 l

SEA l

0.60 l UTE

-0.19 l l

35 l

5 l

SEA l

1.78 l UTE

-0.18 l l

35 l

7 l

MEA l

1.01 l UTE

-0.17 l l

35 l

13 l

MEA l

1.97 l UTE

-0.60 l l

35 l

15 l

MEA l

1.82 l UTE

-0.16 l l

35 l

16 l

SEA l

0.77 l UTE

-0.63 l l

l 35 l

18 l

SEA l

2.39 l UTE

-0.15 l l

l 35 l

19 l

SEA l

1.24 l UTE

-0.52 l l

35 l

20 l

MEA l

1.30 l UTE

-0.12 l l

35 l

21 l

SEA l

1.31 l UTE

-0.11 l l

35 l

32 l

SEA l

0.47 l UTE

-0.20 l l

35 l

33 l

SEA l

1.48 l UTE

-0.11 l l

35 l

35 l

SEA l

1.74 l UTE

-0.10 l l

35 l

43 l

MEA l

1.26 l UTE

-0.12 l l

35 l

48 l

SEA l

2.14 l UTE

-0.19 l l

35 l

49 l

SAI l

1.07 l UTE

-3.22 l l

35 l

55 l

SAI l

0.62 l UTE

-2.74 l

.l 35 l

75 l

SEA l

1.82 l UTE

-0.46 l l

35 l

80 l

MEA l

1.46 l UTE

-0.22 l l

35 l

98 l

MEA l

2.21 l UTE

-0.28 l l

35 l

100 l

SEA l

1.24 l UTE

-0.26 l l,

35 l

102 l

MEA l

1.19 lUTE

-0.26 l l

35 l

103 l

SEA l

1.91 l UTE

-0.32 l l

35 l

104 l

MEA l

1.76 l UTE

-0.26 l l

35 l

105 l

SEA l

0.86 l UTE

-0.28 l l

36 l

6 l

MEA l

1.80 l UTE

-0.68 l l

36 l

8 l

MEA l

1.44 l UTE

-0.57 l l

36 l

9 l

SEA l

1.57 l UTE

-0.17 l l

l 36 l

12 l

SEA l

1.54 l UTE

-0.58 l l

36 l

14 l

SEA l

1.91 l UTE

-0.50 l l

36 l

15 l

SEA l

0.91 l UTE

-0.20 l

Attachment to ICAN069806 Page 35 of127 Table 7 (cost)

"A" OTSG Upper Re5 Area Flaws l

36 l

18 l

SEA l

2.16 l UTE

-0.63 l l

36 l

19 l

MEA l

1.83 l UTE

-0.14 l l

36 l

20 l

MEA l

2.13 l UTE

-0.54 l l

36 l

34 l

SEA l

0.75 l UTE

-0.26 l l

36 l

35 l

MEA l

1.46 l UTE

-0.09 l l

36 l

39 l

MEA l

- 0.70 l UTE

-0.14 l l

36 l

50

-l SEA l

0.73 l UTE

-0.25 l L

l 36 l

76 l

SEA l

2.04 l UTE

-0.22 l l

36 l

83 l

SEA l

2.45 l UTE

-0.05 l l

36 l

100 l

MEA l

1.44 l UTE

-0.18 l l

36 l

103 l

SEA l

1.20 l UTE

-0.36 l l

36 l

105 l

MEA l

1.57 l UTE

' 0.18 l l

l 36

-l 107 l

SEA-l 0.99 l UTE

-0.34 l l

36 l

113 l

SEA l

1.04 l UTE

-0.23 l l-36 l

113 l

SAI l

1.06 l UTE

-1.05 l l

37 l

4 l

SEA l

1.01 l UTE

-0.19 l l

l 37 l

7 l

SEA l

0.54 l UTE

-0.10 l.

l l

37 l

9 l

SEA l

1.63 l UTE

-0.13 l l

37 l

12 l

SEA l

1.23 l UTE

-0.16 l l<

37 l-13 l

SEA l

2.31 l UTE

-0.13 l l

37 l

15 l

SEA l

1.55 l UTE

-0.13 l l-37 l

17 l

MEA l

3.17

-l UTE

-0.14 l l

37 l

18 l

SEA l

1.36 l UTE

-0.15 l l

37 l

23-l SEA l

0.94 l UTE

-0.21 l l

37 l

25 l

MEA l

1.47 l UTE

-0.32 l l

37-l 28 l

SEA l

1.13 l UTE

-0.13 l l

37 l

35 l

SEA l

2.41 l UTE

-0.41 l l

37 l

36 l

MEA l

1.17-l UTE

-0.11 l l

37 l

38

-l MEA l

1.28 l UTE

-0.10 l l

37 l-47 l

SEA l

0.53 l UTE

-0.19 l l

37 l

75 l

SEA l

1.35 l UTE

-0.20 l

[

37 l

82 l

SEA l

3.66 l UTE

-0.08 l 1

37 l

84 l

SEA l

0.35 l UTE

-0.17 l l

37 l

100 l

MEA l

1.68-l UTE

-0.14 l l

37 l

102 l

MEA l

1.87 l UTE

-0.21 l l

37 l

104

-l SEA l

2.46 l UTE

-0.17 l l

37 l

106 l

SEA l

0.75 l UTE

-0.15 l l

37 l

108 l

MEA l

1,72 l UTE

-0.09 l

Attachment to ICAN069806 Page 36 of127 Table 7 (coat) l "A" OTSG Upper Roll Area Flaws l

l 38 l-5 l

SEA l.

1.06 l UTE

-0.16 l

'l 38 l

10 l

MEA l

1.26 l UTE

-0.20 l l

38 l

14 l

MEA l

1.79 l UTE

-0.14 l

[

38 l

15 l

MEA l

2.16 l UTE

-0.16 l l

38 l

18 l

MEA l

2.03 l UTE

-0.15 l l

38 l

21 l

SEA l

1.68 l UTE

-0.18 l l

38 l

22 l

MEA l

1.94 l UTE

-0.16 l I

l 38 l

26 l

SEA l

1.55 lUTE

-0.25 l l

38 l

35 l

SEA

-l 2.58 lUTE

-0.22 l l

38 l

44 l

SEA l

1.59 l UTE

-0.10 l

.l 38 l

46 l

MEA l

3.47 lUTE

-0.28 l l

38 l

51 l

SEA l

1.02 l UTE

-0.25 l l

l 38 l

62 l

SAI l

0.78 l UTE

-2.05 l l

38 l

68-l SEA l

0.73 lUTE

-0.20 l l

38 l

78 l

MEA l

2.09 l UTE

-0.21 l l

38 l

84 l

MEA l

1.71 l UTE

-0.26 l l

38 l

98 l

MEA l

2.00 l UTE

-0.25 l l

38 l

101 l

MEA l

1.63 l UTE

-0.12 l j

l 38 l

104 l

MEA l

2.20 l UTE

-0.11 l l

l 38 l

105 l

MEA l

1.97 l UTE

-0.12 l l

38 l

107 l

SEA l

1.27 l UTE

-0.20 l i

l 38 l

108 l

MEA l

1.11 l UTE

-0.27 l l

38 l

109 l

SEA l

2.03 l UTE

-0.15 l

)

l 38 l

111 l

SEA l

0.89 l UTE

-0.20 l l

38 l

113 l

SEA l

1.87 l UTE

-0.12 l l

39 l

1 l

-SEA l

0.87 l UTE

-0.29 l l

39 l

11 l-MEA l

1.37 lUTE

-0.13 l l

39 l

12 l

MEA l

1.87 l UTE

-0.14 l l

39 l

14 l

MEA l

1.08 l UTE

-0.14 l 1

l 39 l

17 l-MEA l

1.57 l UTE

-0.09 l l

39-l 20 l

SEA l

0.64 l UTE

-0.15 l l

39 l

22 l

SEA l

1.%

l UTE

-0.12 l l

39 l

26 l

MEA l

2.33 l UTE

-0.24 l l

39 l

29 l

MEA l

1.93 l UTE

-0.20 l l

39 l

30 l

MEA l

1.72 l UTE

-0.30 l l

39-l 36 l

MEA l

2.25 l UTE

-0.23 l l

39 l

39 l

MEA l

1.61 l UTE

-0.32 l

[

39 l

53 l

SEA l

1.37 l UTE

-0.26 l

Attachment to 1CAN069806 Page 37 of127 Table 7 (cont)

"A" OTSG Upper Roll Area Flaws l

39 l

66 l

MEA l

0.73 l UTE

-0.24 l l

39 l

84 l

MEA l

0.91 l UTE

-0.20 l l

39 l

99 l

SEA l

0.93 l UTE

-0.14 l l

39 l

101 l

MEA l

1.47 l UTE

-0.20 l l

39 l

103 l

MEA l

1.62 l UTE

-0.18 l l

39 l

105 l

SEA l

1.76 l UTE

-0.17 l l

39 l

116 l

MEA l

1.95 l UTE

-0.55 l l

40 l

1 l

SEA l

3.09 l UTE

-0.22 l l

40 l

8 l

MEA l

1.56 l UTE

-0.15 l l

40 l

10 l

SEA l

2.44 l UTE

-0.13 l l

40 l

13 l

SEA l

2.61 l UTE

-0.16 l l

40 l

16 l

SEA l

1.90 l UTE

-0.29 l l

40 l

18 l

MEA l

1.13 l UTE

-0.19 l l

40 l

22 l

SEA l

0.92 l UTE

-0.27 l l

40 l

23 l

SEA l

2.39 l UTE

-0.21 l l

40 l

30 l

SEA l

1.15 l UTE

-0.23 l l

40 l

47 l

SEA l

1.35 l UTE

-0.20 l l

40 l

69 l

SEA l

1.31 l UTE

-0.11 l l

40 l

72 l

SEA l

2.17 l UTE

-0.29 l l

40 l

103 l

SEA l

1.00 l UTE

-0.57 l l

40 l

111 l

SEA l

1.17 l UTE

-0.13 l l

40 l

117 l

SEA l

2.22 l UTE

-0.56 l l

41 l

5 l

SEA l

2.15 l UTE

-0.13 l l

41 l

9 l

MEA l

2.10 l UTE

-0.09 l l

41 l

10 l

MEA l

2.28 l UTE

-0.16 l l

41 l

13 l

MEA l

1.12 l UTE

-0.16 l l

41 l

14 l

SEA l

2.81 l UTE

-0.09 l l

41 l

15 l

MEA l

1.82 l UTE

-0.13 l l

41 l

16 l

SEA l

1.40 l UTE

-0.07 l l

41 l

18 l

SEA l

1.20 l UTE

-0.10 l j

l 4_1 l

20 l

MEA l

1.27 l UTE

-0.10 l l

l 41 22 l

MEA l

1.98 l UTE

-0.11 l i

l 41 24 l

SAI l

0.23 l UTE

-1.09 l l

l 41 26 l

MEA l

1,18 l UTE

-0.23 l l

41 29 l

MEA l

1.43

'l UTE

-0.23 l l

41 38 l

SEA l

2.57 l UTE

-0.22 l l

41 47 l

SEA l

2.03 l UTE

-0.28 l l

41 49 l

SEA l

2.30 l UTE

-0.36 l L__--_-------__------.----

Attachment to 1CAN069806 Page 38 of127 Table 7 (cost)

"A" OTSG Upper Roll Area Flaws 34 l

41

-l 52 l

SEA l

2.51 l UTE

-0.25 1

41 l

53 l

SEA l

1.78 l UTE

-0.31 l

41 l

59 l

SEA l

0.71 l UTE

-0.21

[

41 l_

83 l

SEA l

1.41 l UTE

-0.19 j

l 41 1

84 l

MEA l

1.54 l UTE

-0.20 l

41 l

87 l

MEA l

1.53 l UTE

-0.08 l

41 l

99 l

MEA l

1.71 l UTE

-0.31 l

41 l

102 l

MEA l

1.57 l UTE

-0.14 l

41 l

106 l

SEA l

0.94 l UTE

-0.31 l

41 l

110 l

MEA l

1.52 l UTE

-0.18 l

41 l

112 l

MEA l

1.47 l UTE

-0.16 l

42 l

11 l

SEA l

1.97 l UTE

-0.15 1

42 l

13 l

MEA l

2.29 l UTE

-0.13 l

42 l

14 l

MEA l

2.02 l UTE

-0.12 l

42 l

15 l

SEA l

1.49 l UTE

-0.12 l

42 l

16 l

SEA l

1.06 l UTE

-0.18 l

42 l

19 l

SEA l

0.87 l UTE

-0.14 l

42 l

20 l

SEA l

1.41 l UTE

-0.17 l

42 l

23 l

MEA l

2.34 l UTE.

-0.05 l

42 l

27 l

SEA l

1.59 l UTE

-0.23 l

42 l

29 l

SEA l

2.84 l UTE

-0.28

~

l 42 l

36 l

SEA l

1.29 l UTE

-0.18 l

42 l

45 l

SEA I

2.21 l UTE

-0.36 l

42 l

48 l

SEA l

1.17 l UTE

-0.21 l

42 l

72 l

SEA l

0.78 l UTE

-0.14 l

42 l

85 l

SEA l

1.14 l UTE

-0.23 l

42 l

99 l

SEA l

0.81 l UTE

-0.13 l

42 l

100 l

MEA l

1.37 l UTE

-0.33 l

42 l

105 l

MEA l

1.84 l UTE

-0.10 l

-42 l

106 l

MEA l

1.34 l UTE

-0.51 l

42 l

108 l

SEA l

1.51 l UTE

-0.14 l --

42 l

109 l

SEA l

0.92 l UTE

-0.29 l

42 l

110 l

MEA l

2.05 l UTE

-0.18 l

43 1

11 l

MEA l

1.19 I UTE

-0.14 l

43 l

14 l

SEA l

1.31 l UTE

-0.22 1

43 l

17 l

SEA l

0.89 l UTE

-0.09 l

43 l

19 l

MEA l

2.98 l UTE

-0.08 1

43 l

21 l

SEA l

1.93 l UTE

-0.06

! 3 1CAN069806 Page 39 of127 1

Table 7 (cont)

"A" OTSG Upper Roll Area Maws l

43 l

30 l

SEA l

1.24 l UTE

-0.20 l l

43 l

37 l

SAI l

0.51 l UTE

-1.% l l

l 43 l

38 l

MEA l

2.03 l UTE

-0.19 l l

43 l

41 l

SEA l

1.91 l UTE

-0.22 l l

43 l

48 j

SEA l

1.75 l UTE

-0.27 l I

l 43 l

54 l

SEA l

0.87 l UTE

-0.34 l l

43 l

62 l

SEA l

1.25 l UTE

-0.35 l l

43 l

80 l

SEA l

1.87 l UTE

-0.04 l l

43 l

85 l

MEA l

0.93 l UTE

-0.24 l l

43 l

88 l

SEA l

0.62 l UTE

-0.28 l l

43 l

98 l

SEA l

2.04 l UTE

-0.47 l l

43 l

107 l

MEA l

1.83 l UTE

-0.48 l l

43 l

108 l

MEA l

0.98 l UTE

-0.16 l l

l 43 l

111 l

SEA l

1.79 l UTE

-0.17 l l

43 l

118 l

MEA l

0.59 l UTE

-0.70 l l

44 l

7 l

SEA l

1.26 l UTE

-0.16 l l

l 44 l

14 l

MEA l

1.34 l UTE

-0.13 l l

l 44 l

15 l

MEA l

3.76 l UTE

-0.25 l l

44 l

18 l

SEA l

1.22 l UTE

-0.09 l l

44 l

20 l

MEA l

1.70 l UTE

-0.07 l l

44 l

21 l

SEA l

1.16 l UTE

-0.16 l l

44 l

23 l

MEA l

1.22 l UTE

-0.17 l l

l 44 l

24 l

MEA l

1.11 l UTE

-0.11 l l

44 l

27 l

MEA l

1.13 l UTE

-0.13 l l

44 l_

28 l

SEA l

1.82 l UTE

-0.31 l l

44 l

41 l

SEA l

0.89 l UTE

-0.23 l

)

l 44 l

50 l

SEA l

0.81 l UTE

-0.19 l l

l 44 l

52 l

MEA l

1.92 l UTE

-0.23 l l

44 l

53 l

SEA l

1.17 l UTE

-0.23 l l

44 l

67 l

MEA l

1.41 l UTE

-0.31 l l

l 44 l

73 l

SEA l

1.60 l UTE

-0.25 l l

l 44 l

86 l

SEA l

1.18 l UTE

-0.26 l l

44 l

87 l

SEA l

1.32 l UTE

-0.42 l l

44 l

101 l

SEA l

1.35 l UTE

-0.09 l i

l 44 l

112 l

SEA l

1.28 l UTE

-0.25 l l

44 l

113 l

MEA l

0.60 l UTE

-0.20 l l

44 l

119 l

MEA l

2.03 l UTE

-0.51 l l

45 l

11 l

SEA l

1.52 l UTE

-0.13 l

Attachment to 1CAN069806 Page 40 of127 Tatde 7 (coat) l "A" OTSG Upper Rob Area Plaws P99"RF9"!!"Ml"!!E l

45 l

20 l

SEA l

2.34 l UTE

-0.12 l l

45 l

30 l

MEA l

1.09 l UTE

-0.14 l 1

45 l

31 l

SEA l

1.85 l UTE

-0.42 l l

45 l

39 l

SEA l

2.06 l UTE

-0.25 l l

45 l

40 l

MEA l

5.32 l UTE

-0.06 l l

45 l

41 l

SEA l

2.56 l UTE

-0.10 l l

45 l

53 l

SEA l

2.14 l UTE

-0.28 l l

45 l

67 l

SEA l

1.11 l UTE

-0.24 l l

45 l

80 l

SEA l

1.19 l UTE

-0.37 l l

l 45 l

85 l

SEA l

1.31 l UTE

-0.27 l l:

l 45 l

86 l

MEA l

2.01 l UTE

-0.30 - l I

l 45 l

97 l

MEA l

1.60 l UTE

-0.42 l l

45 l

99 l

SEA l

1.93 l UTE

-0.42 l l

45 l

100 l

SEA l

0.75 l UTE

-0.28 l l

45 l

101 l

SEA l

1.05 l UTE

-0.31 l l

45 l

106 l

SEA l

1.25 l UTE

-0.13 l l

45 l

108 l

SEA l

1.40 l UTE

-0.22 l l

45 l

112 l

SEA l

1.89 l UTE

-0.16 l l

45 l

116 l

MEA l

1.19 l UTE

-0.12 l l

45 l

lid l

MEA l

2.05 l UTE

-0.49 l l

45 l

120 l

SEA l

1.33 l UTE

-0.53 l l

l 46 l

9 l

MEA l

2.79 l UTE

-0.24 l l

l 46 l

11 l

SEA l

0.84 l UTE

-0.17 l l

l 46 l

15 l

MEA l

2.16 l UTE

-0.13 l l

46 l

19 l

MEA

]

1.16 l UTE

-0.12 l 1

l 46 l

20 l

SEA l

2.04 l UTE

-0.36 l l

46 l

23 l

MEA l

2.04 l UTE

-0.11 l l

l 46 l

25 l

SEA l

1.33 l UTE

-0.12 l l

46 l

26 l

SEA l

1.99 l UTE

-0.34 l l

'l 46 l

29 l

MEA l

1.68 l UTE

-0.23 l l

46 l

38 l

SEA l

1.26 l UTE

-0.21 l l.

l 46 l

41 l

SEA l

1.65 l UTE

-0.26 l l

46 l

63 1

SEA l

1.00

-l UTE

-0.28 l l

46 l

72 l

SEA l

1.58 l UTE

-0.19 l l

46 l

78 l

SEA l

0.58 l UTE

-0.13 l l

46 l

91 l

SEA l

1.51 l UTE

-0.12 l l

I 46 I

98 l

SEA I

3.02 l UTE

-0.27 l l

46 l

105 l

SEA l

2.19 l UTE

-0.12 l

l Attachment to l

1CAN%9806 Page 41 cf127 Table 7 (cost)

"A" OTSG Upper Roll Area Flaws l

46 l

112 l

SEA l

0.93 l UTE

-0.55 l l

47 l

16 l

SEA l

1.42 l UTE

-0.20 l l

47 l

27 l

SEA l

1.04 l UTE

-0.18 l l

l 47 l

29 l

MEA l

0.53 l UTE

-0.20 l l

47 l

40 l

SEA l

1.53 l UTE

-0.25 l l

47 l

54 l

MEA l

1.83 l UTE

-0.20 l l

47 l

64 l

MEA l

1.82 l UTE

-0.26 l l

l 47 l

65 l

MEA l

1.63 l UTE

-0.17 l l

l 47 l

78 l

SEA l

1.70 l UTE

-0.27 l l

l 47 l

79 l

SEA l

2.03 l UTE

-0.64 l l

l 47 l

81 l

SEA l

2.79 l UTE

-0.12 l l

47 l

100 l

MEA l

1.50 l UTE

-0.30 l l

47 l

102

-l SEA l

0.54 l UTE

-0.21 l l

47 l

103 l

SEA l

1.29 l UTE

-0.25 l l

47 l

109 l

SEA l

1.73 l UTE

-0.16 l l

l 47 l

111 l

MEA l

1.03 l UTE

-0.16 l l

48 l

7 l

SEA l

0.95 l UTE

-0.11 l l

48 l

10 l

SEA l

2.40 l UTE

-0.24 l l

48 l

11 l

MEA l

1.82 l UTE

-0.15 l l

48 l

22 l

SEA l

1.46 l UTE

-0.19 l l

l 48 l

27 l

SEA l

1.74 l UTE

-0.83 l l

48 l

30 l

SEA l

1.73 l UTE

-0.17 l l

48 l

33 l

SEA l

0.91 l UTE

-0.19 l l

48 l

43 l

MEA l

1.56 l UTE

-0.20 l l

l 48 l

44 l

MEA l

1.34 l UTE

-0.14 l l

l 48 l

45 l

SEA l

1.62 l UTE

-0.21 l l

l 48 l

46 l

SEA l

1.28 l UTE

-0.14 l l

48 l

47 l

SEA l

1.81 l UTE

-0.18 l l

48 l

65 l

MEA l

1.91 l UTE

-0.40 l l

l 48 l

69 l

SEA l

1.08 l UTE

-0.17 l l

48 l

88 l

SEA l

0.58 l UTE

-0.51 l l

48 l

91 l

SEA l

0.82 l UTE

-0.30 l l

48 l

102 l

MEA l

1.59 l UTE

-0.24 l l

48 l

104 l

SEA l

1.75 l UTE

-0.13 l l

48 l

111 l

SEA l

1.39 l UTE

-0.42 l l

48 l

112 l

SEA l

1.35 l UTE

-0.13 l l

48 l

116 l

SEA l

1.44 l UTE

-0.13 l l

48 l

122 l

SEA l

0.68 l UTE

-0.30 l L,-____-_____-

Attachm:nt to 1CAN069806 Page 42 of127 Table 7 (cont)

"A" OTSG Upper Roll Area Flaws 49 11

-0.19 49 17 l

MEA l

2.44 l UTE

-0.08 49 22 l

MEA l

1.77 l UTE

-0.29 49 24 l

MEA l

0.58 l UTE

-0.39 49 26 l

MEA l

1.65 l UTE

-0.40 49 29 l

SEA l

2.06 l UTE

-0.29 49 30 l

SEA l

1.62 l UTE

-0.16 49 32 l

SEA l

1.91 l UTE

-0.14 49 33 l

MEA l

1.33 l UTE

-0.26 49 34 l

MEA l

1.75 l UTE

-0.19 49 41 l

MEA l

1.70 l UTE

-0.15 49 59 l

SEA l

2.30 l UTE

-0.08 49 78 l

SEA l

1.17 l UTE

-0.34 49 101 l

SEA l

1.24 l UTE

-0.37 49 109 l

SEA l

1.41 l UTE

-0.21 49 124 l

SEA l

1.60 l UTE

-0.29 50 11 l

SEA l

2.21 l UTE

-0.39 50 17 l

MEA l

1.87 l UTE

-0.30 50 20 l

SEA l

1.71 l UTE

-0.15 50 28 l

SEA l

0.71 l UTE

-0.13 50 30 l

SEA l

0.76 l UTE

-0.18 50 39 l

MEA l

1.10 l UTE

-0.22 50 43 l

MEA l

1.21 l UTE

-0.17 50 68 l

SEA l

1.43 l UTE

-0.18 50 69 l

SEA l

0.66 l UTE

-0.22 50 101 l

SEA l

1.98 l UTE

-0.32 50 107 l

SEA l

1.22 l UTE

-0.35 50 108 l

SEA l

1.12 l UTE

-0.16 50 110 l

SEA l

1.04 l UTE

-0.12 50 111 l

MEA l

1.35 l UTE

-0.34 50 111 l

MEA l

2.12 l UTE

-0.35 50 116 l

SEA l

0.48 l UTE

-0.08 51 8

l MEA l

0.98 l UTE

-0.34 51 11 l

SEA l

2.59 l UTE

-0.17 51 13 l

SEA l

0.83 l UTE

-0.13 51 17 l

SEA l

1.90 l UTE

-0.15 51 22 l

SEA l

1.34 l UTE

-0.26 51 29 l

SEA l

1.29 l UTE

-0.21 51 30 l

SEA l

1.33 l UTE

-0.17

E Attachment to 1CAN069806 l

Page 43 cf127 Table 7 (coat)

"A" OTSG Upper Roll Area Flaws 51 51 l

33 l

MEA l

2.11 l UTE

-0.24 l 51 l

40 l

MEA l

0.72 l UTE

-0.16 l l

51 l

44 l

SEA l

1.31 l UTE

-0.19 l j

51 l

51 l

SEA l

0.55 l UTE

-0.12 l 51 l

63 l

SEA l

0.74 l UTE

-0.35 l 51 l

65 l

MEA l

0.82 l UTE

-0.22 l 51 l

66 l

MEA l

1.01 l UTE

-0.24 l 51 l

75 l

SEA l

0.55 l UTE

-0.20 l 51 l

80 l

MEA l

1.33 l UTE

-0.24 l l

51 l

87 l

SEA l

1.73 l UTE

-0.23 l l

51 l

88 l

MEA l

1.07 l UTE

-0.36 l l

51 l

102 l

SEA l

2.32 l UTE

-0.40 l l

l 51 l

111 l

MEA l

0.81 l UTE

-0.14 l l

51 l

112 l

MEA l

1.64 l UTE

-0.09 l l

51 l

121 l

MEA l

1.15 l UTE

-0.24 l 51 l

122 l

MEA l

0.68 l UTE

-0.31 l l

52 l

12 l

SVI l

1.04 l UTE

-2.19 l 52 l

31 l

MEA l

0.79 l UTE

-0.16 l 52 l

40 l

SEA l

1.99 l UTE

-0.41 l 52 l

42 l

SEA l

1.08 l UTE

-0.39 l 52 l

44 l

SEA l

2.86 l UTE

-0.13 l 52 l

46 l

SEA l

1.20 l UTE

-0.09 l 52 l

55 l

SEA l

1.2!

l UTE

-0.27 l l.

52 l

68 l

SEA l

1.52 l UTE

-0.20 l l

52 l

105 l

SEA l

0.34 l UTE

-0.54 l f

52 l

110 l

MEA l

1.69 l UTE

-0.16 l 52 l

111 l

SEA l

1.23 l UTE

-0.12 l l

l-52 l

121 l

SEA i

1.38 l UTE

-0.13 l l

l 52 l

122 l

MEA l

1.08 l UTE

-0.11 l

)

l 53 l

21 l

MEA l

1.39 l UTE

-0.11 l l

53 l

32 l

SEA l

0.22 l UTE

-0.24 l l

53 l

35 l

MEA l

0.98 l UTE

-0.15 l 53 l

43 l

MEA l

1.97 l UTE

-0.11 l 53 l

62 l

SAI l

0.91 l UTE

-1.77 l

(

53 l

88 l

SEA l

1.49 l UTE

-0.31 l 53 l

103 l

MEA l

1.25 l UTE

-0.28 l 53 l

109 l

SEA l

1.52 l UTE

-0.23 l 53 l

110 l

SEA l

2.44 l UTE

-0.14 l

Attachment ts 1CAN069806 Page 44 of127 Table 7 (cost)

"A" OTSG Upper Roll Area Flaws l

53 l

112 l

SEA l

1.54 l UTE

-0.14 l l

53 l

113 l

SEA l

2.44 l UTE

-0.35 l l

53 l

122 l

SEA l

1.47 l UTE

-0.15 l l

53 l

123 l

SEA l

1.59 l UTE

-0.18 l l

53 l

124 l

MEA l

2.00 l UTE

-0.59 l l

53 l

126 l

MEA l

1.33 l UTE

-0.52 l l

l 54 l

13 l

SEA l

2.44 l UTE

-0.17 l l

54 l

15 l

SEA l

0.93 l UTE

-0.21 l l

54 l

18 l

SEA l

1.%

l UTE

-0.37 l l

54 l

19 l

SEA l

2.88 l UTE

-0.14 l l

54 l

21 l

SEA l

1.30 l UTE

-0.17 l l

l 54 l

22 l

SEA l

1.91 l UTE

-0.15 l l

l 54 l

32 l

SEA l

0.83 l UTE

-0.40 l l

54 l

34 l

MEA l

1.34 l UTE

-0.28 l

)

I l

54 l

34 l

SAI l

0.86 l UTE

-1.72 l l

54 l

35 l

SEA l

2.61 l UTE

-0.25 l l

54 l

36 l

SEA l

1.07 l UTE

-0.22 l l

54 l

41 l

SAI l

0.48 l UTE

-1.03 l i

l 54 1

43 l

SEA l

2.10 l UTE

-0.17 l l

54 l

62 l

SEA l

1.88 l UTE

-0.32 l l

54 l

70 l

SEA l

0.63 l UTE

-0.21 l

{

l l

54 l

74 l

SEA l

1.54 l UTE

-0.24 l j

l 54 l

91 l

SEA l

1.42 l UTS

+23.90 l l

l 54 l

106 l

MEA l

1.93 l UTE

-0.13 l l

54 l

110 l

MEA l

1.32 l UTE

-0.15 l I

l 54 l

115 l

SEA l

1.45 l UTE

-0.33 l

)

l 54 l

117 l

SEA l

2.74 l UTE

-0.27 l l

l 54 l

123 l

MEA l

3.15 l UTE

-0.28 l I

l 54 l

127 l

MEA l

1.31 l UTE

-0.36 l l

54 l

127 l

SAI l

0.63 l UTE

-1.18 l l

55 l

14 l

SEA l

1.94 l UTE

-0.34 l l

55 l

15 l

SEA l

1.10 l UTE

-0.18 l l

55 l

21 l

MEA l

1.94 l UTE

-0.13 l j

l 55 l

29 l

SEA l

1.35 l UTE

-0.12 l l

55 l

32 l

MEA l

0.91 l UTE

-0.13 l l

55

_l 35 l

SEA l

0.98 l UTE

-0.31 l l

55 l

41 l

SEA l-1.09 l UTE

-0.11 l l

55 1

43 l

SEA l

1.68 l UTE

-0.11 l!

i

_a

Attachment to 1CAN069806 Page 45 cf127 j

Table 7 (cont)

"A" OTSG Upper Roll Area Flaws l

l 55 l

66 l

SEA l

1.49 l UTE

-0.37 l l

55 l

69 l

SEA l

1.29 l UTE

-0.40 l l

l 55 l

77 l

SEA l

2.43 l UTE

-0.40 l l

l 55 l

88 l

SEA l

0.58 l UTE

-0.24 l l

55 l

89 l

MEA l

1.31 l UTE

-0.43 l l

55 l

92 l

MEA l

0.80 l UTE

-0.11 l l

55 l

104 l

SEA l

2.32 l UTE

-0.17 l l

55 l

105 l

SEA l

0.98 l UTE

-0.41 l l

55 l

111 l

MEA l

1.65 l UTE

-0.09 l l

55 l

111 l

SV1 l

2.89 l UTE

-2.20 l l

55 ~

l 119 l

SEA l

1.02 l UTE

-0.11 l l

55 l

124 l

SAI l

1.08 l UTE

-1.51 l l

l l

55 l

126 l

SAI l

1.16 l UTE

-1.36 l l

l 56 l

10 l

SEA l

2.07 l UTE

-0.16 l l

56

'l 15 l

SEA l

1.25 l UTE

-0.28 l l

56 l

16 l

SEA l

1.76 l UTE

-0.31 l l

56 l

25 l

SEA l

1.52 l UTE

-0.27 l l

56 l

29 l

SEA l

0.95 l UTE

-0.23 l l

56 l

33 l

SEA l

1.38 l UTE

-0.15 l l

56 l

41 l

SEA l

0.61 l UTE

-0.28 l l

56 l

43 l

SEA l

1.60 l UTE

-0.29 l l

56 l

45 l

SEA l

1.20 l UTE

-0.36 l l

56

\\

60 l

SEA

\\

0.79 l UTE

-0.55 l l

56 l

105 l

SEA l

1.93 l UTE 0.19l l

l 56 l

113 l

SEA l

1.21 l UTE

-0.11 l l

56 l

115 l

MEA l

0.85 l UTE

-0.07 l l

56 l

119 l

MEA l

1.69 l UTE

-0.16 l l

56 l

120 l

SEA l

0.73 l UTE

-0.16 l l

56 l

123 l

MAI l

0.78 l UTE

-1.89 l l

57 l

12 l

MEA l

2.04 l UTE

-0.26 l l

57 l

13 l

SEA l

1.53 l UTE

-0.12 l l

l l

57 l

19 l

SEA l

1.30 l UTE

-0.31 l l

57 l

32 l

SEA l

1.55 l UTE

-0.16 l l

57 l

34 l

MEA l

1.22 l UTE

-0.14 l l

57 l

35 l

MEA l

2.61 l UTE

-0.25 l l

57 l

36 l

MEA l

1.75 l UTE

-0.12 l l

57 l

37 l

SEA l

2.46 l UTE

-0.21 l l

57 l

42

\\

SEA

\\

1.31 l UTE

-0.15 l l

l

Attachment to 1CAN069806 Page 46 of127 Table 7 (cost)

"A" OTSG Upper Rau Area Flaws l

57 l

44 l

MEA l

1.49 l UTE

-0.15 l l

57 l

46 l

MEA l

3.22 l UTE

-0.13 l l

57 l

57 l

SEA l

0.87 l UTE

-0.18 l l

57 l

120 l

MEA l

1.81 l UTE

-0.24 l l

57 l

123 l

MEA l

1.39 l UTE

-0.18 l l

58 l

7 l

SAI l

0.61 l UTE

-2.18 l l

58 l

17 l

MEA l

1.68 l UTE

-0.15 l l

58 l

19 l

SEA l

0.86 l UTE

-0.24 l l

58 l

20 l

SEA l

1.29 l UTE

-0.26 l l

58 l

21 l

SAI l

0.56 l UTE

-1.50 l l

58 l

33 l

SEA l

1.89 l UTE

-0.18 l l

58 l

43 l

SEA l

1.38 l UTE

-0.23 l l

58 l

44 l

SEA l

1.80 l UTE

-0.18 l l

58 l

48 l

MEA l

0.60 l UTE

-0.22 l l

58 l

61 l

MEA l

0.93 l UTE

-0.17 l l

58 l

105 l

SEA l

1.47 l UTE 0.26l l

58 l

107 l

SEA l

1.48 l UTE

-0.07 l l

58 l

121 1

SEA l

1.26 l UTE

-0.17 l l

58 l

125 l

SEA l

2.02 l UTE

-0.33 l l

58 l

129 l

MEA l

0.95 l UTE

-0.35 l l

59 l

18 l

MEA l

1.38 I UTE

-0.17 l l

59 l

31 l

SEA l

0.86 l UTE

-0.29 l l

59 l

35 l

MEA l

1.28 l UTE

-0.33 l l

59 l

36 l

SEA l

1.64 l UTE

-0.36 l l

l 59 l

42 l

MEA l

1.57 IUTE

-0.21 l l

59 l

66 l

MEA l

1.70 l UTE

-0.11 l l

59 l

88 l

SEA l

0.87 l UTE

-0.61 l l

59 l

115 l

SEA l

0.71 l UTE

-0.10 l l

59 l

121 l

SEA l

0.94 l UTE

-0.11l l

60 l

12 l

MEA l

3.08 l UTE

-0.26 l l

60 l

14 l

MEA l

2.79 l UTE

-0.24 l l

60 l

16 l

MEA l

2.35 l UTE

-0.21 l l

60 l

18 l

MEA l

1.00 l UTE

-0.16 l l

60 l

19 l

MEA l

2.34 l UTE

-0.25 l l

60 l

20 l

SEA l

1.61 l UTE 0.28l l

60 l

37 l

SEA l

1.51 l UTE

-0.20 l l

60 l

48 l

SEA l

1.85 l UTE

-0.40 l l

60 l

54 l

SEA l

0.65 l UTE

-0.09 l LL ____

i Attachment to ICANM9806 Page 47 cf127 Table 7 (coat)

"A" OTSG Upper Roll Area Flaws 60 60 68 l

SEA l

1.00 l UTE

-0.12 l 60 69 l

SEA l

1.32 l UTE

-0.42 l l

60 75 l

SEA l

0.32 l UTE

-0.24 l I

60 89 l

SEA l

0.61 l UTE

-0.49 l 60 90 l

SEA l

1.50 l UTE

-0.21 l 60 107 l

SEA l

2.35 l UTE

-0.11l 60 123 l

MEA l

1.42 l UTE

-0.13 l l

60 125 l

SEA l

1.74 l UTE

-0.21 l l

60 127 l

SEA l

1.70 l UTE

-0.34 l 60 129 l

MEA l

1.42 l UTE

-0.49 l 61 33 l

MEA l

1.67 l UTE

-0.22 l 61 43 l

SEA l

1.56 l UTE

-0.16 l 61 45 l

MEA l

2.15 l UTE

-0.14 l 61 53 l

SEA l

1.20 l UTE

-0.19 l 61 58 l

MEA l

1.04 l UTE

-0.49 l 61 59 l

SEA l

0.77 l UTE

-0.11 l 61 67 l

MEA l

0.42 l UTE

-0.13 l i

61 68 l

MEA l

1.06 l UTE

-0.39 l 61 87 l

SEA l

0.85 l UTE

-0.25 l 61 89 l

SEA l

1.65 l UTE

-0.33 l 61 103 l

SEA l

0.91 l UTE

-0.21 l 61 112 l

MEA l

1.54 l UTE

-0.34 l 61 113 l

MEA l

1.26 l UTE

-0.11 l 61 115 l

SEA l

1.30 l UTE

-0.10 l 61 119 l

MEA l

0.57 l UTE

-0.31 l 61 120 l

SEA l

1.26 l UTE

-0.10 l 61 121 l

MEA l

1.62 l UTE

-0.30 l 62 14 l

SEA l

1.71 l UTE

-0.24 l 62 19 l

MEA l

1.79 l UTE

-0.22 l 62 20 l

SEA l

1.12 lUTE

-0.27 l 3

62 23 l

MEA l

2.68 l UTE

-0.23 l l

62 24 l

SEA l

1.37 l UTE

-0.23 l 62 40 l

SEA l

2.17 l UTE

-0.25 l 62 57 l

SEA l

0.99 l UTE

-0.28 l 62 59 l

SEA l

1.63 l UTE

-0.49 l l

62 109 l

MEA l

1.09 l UTE

-0.12 l l

62 110 l

MEA l

1.71 l UTE

-0.35 l i

62 111 l

SEA l

1.23 l UTE

-0.14 l

Attachment ts 1CAN069806 Page 48 of127 Table 7 (cont)

"A" OTSG Upper Roll Area Flaws l

62 l

125 l

SEA l

2.30 l UTE

-0.54 l l

63 l

33 l

SEA l

1.26 l UTE

-0.21 l l

63 l

44 l

SEA l

2.21 l UTE

-0.24 l

[

63 l

45 l

MAI l

1.05 l UTE 1.89l l

63 l

111 l

SEA l

2.18 l UTE

-0.08 l l

63 l

113 l

SEA l

2.38 l UTE

-0.13 l l

63 l

114 l

SEA l

2.78 l UTE

-0.52 l l

63 1

115 l

SEA l

0.92 l UTE

-0.15 l l

63 l

116 l

MEA l

0.94 l UTE

-0.72 l l

63 l

118 l

SEA l

2.66 l UTE

-0.59 l l

64 l

14 l

SEA l

3.11 l UTE

-0.20 l l

64 l

15 l

MEA l

2.58 l UTE

-0.30 l l

64 l

17 l

SEA l

2.06 l UTE

-0.29 l l

64 l

18 l

SEA l

1.75 l UTE

-0.27 l l

64 l

20 l

SEA l

0.79 l UTE

-0.26 l l

64 l

71 l

SEA l

0.78 l UTE

-0.28 l l

64 l

78 l

SAI l

0.38 l UTE

-0.88 l l

64 l

119 l

SEA l

1.32 l UTE

-0.28 l l

64 l

129 l

SVI l

0.92 l UTE

-1.18 l.

l 65 l

7 l

SVI l

1.9 l UTE

-1.93 l l

65 l

9 l

SEA l

2.15 l UTE

-0.20 l l

65 l

9 l

SVI l

0.36 l UTE

-2.24 l l

65 l

25 l

SEA l

2.27 l UTE

-0.22 l l

65 l

30 l

SEA l

0.%

l UTE

-0.32 l l

65 l

36 l

SEA l

1.07 l UTE

-0.27 l l

65 l

37 l

SEA l

0.95 l UTE

-0.37 l l

65 l

38 l

SEA l

2.91 l UTE

-0.21 l l

65 l

39 l

MEA l

1.59 l UTE

-0.33 l l

65 l

45 l

MEA l

1.44 l UTE

-0.15 l l

65 l

58 l

MEA l

1.65 l UTE

-0.55 l l

l 65 l

70 l

MEA l

1.24 l UTE

-0.40 l l

65 l-104 l

MEA l

0.60 l UTE

-0.31 l l

l 65 l

108 l

SEA l

2.72 l UTE

-0.13 l l

65 l

118 l

SEA l

1.08 lUTE

-0.10 l l

65 l

126 l

SEA l

1.56 l UTE

-0.20 l l

66 l

10 l

SAI l

0.49 l UTE

-1.% l l

66 l

12 l

SVI l

0.14 l UTE

-1.71 l l

66 l

18 l

MEA l

1.27 l UTE

-0.23 l

Attac,hment to 1CAN069806 Page 49 of127 Table 7 (cont)

"A" OTSG Upper Rou Area Maws l

66 l

37 l

MEA l

0.92 l UTE

-0.29 l l

66 l

90 l

SEA l

0.80 l UTE

-0.23 l l

66 l

97 l

SEA l

0.85 l UTE

-0.26 l l

66 l

109 l

SEA l

2.01 l UTE

-0.27 l l

66 l

121 l

SEA l

1.79 l UTE

-0.07 l l

66 l

131 l

SEA l

2.05 l UTE

-0.12 l l

66 l

131 l

SAI l

1.43 l UTE

-0.95 l l

67 l

10 l

SEA l

2.27 l UTE

-0.20 l l

67 l

14 l

SEA l

3.00 l UTE

-0.21 l l

67 l

15 l

SEA l

1.05 l UTE

-0.25 l l

67 l

17 l

MEA l

1.72 l UTE

-0.17 l l

67 l

18 l

SEA l

1.56 l UTE

-0.21 l l

67 l

19 l

MEA l

1.91 l UTE

-0.18 l l

67 l

35 l

MEA l

1.56 l UTE

-0.23 l l

67 l

40 l

SEA l

1.07 l UTE

-0.21 l l

67 l

90 l

SEA l

0.68 l UTE

-0.21 l l

67 l

92 l

SEA l

1.24 l UTE

-0.28 l l

67 l

118 l

SEA l

1.22 l UTE

-0.12 l l

67 l

121 l

SEA l

1.10 l UTE

-0.21 l l

67 l

127 l

MEA l

0.63 l UTE

-0.16 l l

68 l

9 l

SVI l

0.8 l UTE

-1.99 l l

68 l

19 l

SEA l

2.92 l UTE

-0.14 l l

68 l

20 l

SEA l

2.69 l UTE

-0.26 l l

68 l

21 l

SEA l

1.84 l UTE

-0.13 l l

68 l

23 l

SEA l

1.60 l UTE

-0.14 l l

68 l

31 l

SEA l

1.75 l UTE

-0.24 l l

68 l

36 l

SEA l

0.%

l UTE

-0.24 l l

68 l

59 l

MEA l

0.59 l UTE

-0.25 l l

68 l

59 l

MEA l

1.57 l UTE

-0.27 l l

68 l

70 l

SEA l

1.13 l UTE

-0.37 l l

68 l

92 l

SEA l

1.13 l UTE

-0.24 l l

68 l

93 l

SEA l

0.83 l UTE

-0.27 l l

68 l

105 l

SEA l

1.15

_l UTE

-0.18 l l

68 l

112 l

SEA l

0.98 l UTE

-0.13 l l

68 l

114 l

SEA l

1.04 l UTE

-0.08 l l

68 l

121 l

SEA l

1.63 l UTE

-0.33 l l

69 l

27 l

MEA l

1.87 l UTE

-0.16 l l

69 l

29 l

SEA l

0.90 l UTE

-0.16 l i

1

Attachment to 1CANM9806 Page 50 of127 Table 7 (cost)

"A" OTSG Upper Roll Area Flaws l

69 l

61 l

MEA l

1.36 l UTE

-0.30 l l

69 l

61 l

MEA l

1.95 l - UTE

-0.30 l l

69 l

69 l

MEA l

1.67 l UTE

-0.29 l l

69 l

69 l

MEA l

1.22 l UTE

-0.29 l l

69 l

105 l

SEA l

1.19 l UTE

-0.14 l l

69 l

107 l

SEA l

1.41 l UTE

-0.15 l l

69 l

128 l

SEA l

1.70 l UTE

-0.35 l l

70 l

18 l

SEA l

2.64 l UTE

-0.22 l l

70 l

20 l

MEA l

1.77 l UTE

-0.20 l l

70 l

20 l

SCI l

3.23 l UTE

-1.13 l l

70 l

20 l

SCI l

3.23 l UTE

-1.13 l l

70 l

21 l

MEA l

1.42 l UTE

-0.15 l l

70 l

40 l

SEA l

1.26 l UTE

-0.21 l l

70 l

95 l

SEA l

1.90 l UTE

-0.37 l l

70 l

103 l

MEA l

1.36 l UTE

-0.37 l l

70 l

119 l

SEA l

1.63 l UTE

-0.27 l l

71 l

112 l

SEA l

0.65 l UTE

-0.09 l l

71 l

131 l

SEA l

0.57 l UTE

-0.89 l l

72 l

21 l

SEA l

0.61 l UTE

-0.17 l l

72 l

24 l

SEA l

1.05 l UTE

-0.19 l l

72 l

25 l

SEA l

0.78 l UTE

-0.16 l l

72 l

31 l

SEA l

1.24 l UTE

-0.18 l l

l 72 l

37 l

SEA l

0.98 l UTE

-0.32 l l

72 l

40 l

SEA l

1.69 l UTE

-0.25 l l

72 l

59 l

MEA l

1.48 l UTE

-0.27 l l

72 l

59 l

MEA l

1.71 l UTE

-0.36 l l

72 l

107 l

SEA l

0.51 l UTE

-0.16 l l

72 l

118 l

SEA l

2.48 l UTE

-0.38 l l-l 72 l

119 l

SEA l

1.33 l UTE

-0.12 l l

72 l -125 l

SEA l

2.00 l UTE

-0.23 l l

72 l

126 l

MEA l

0.86 l UTE

-0.65 l l

73 l

25 l

SEA l

1.20 l UTE

-0.14 l l

73 l

31 l

SEA l

0.84 l UTE

-0.16 l l

73 l

37 l

SEA l

1.42 l UTE

-0.18 l l

73 l

48 l

MEA l

0.93 l UTE

-0.13 l l-73 l

93 l

SEA l

1.35 l UTE

-0.33 l l

73 l

103 l

MEA l

2.34 l UTE

-0.38 l l

73 l

116 l

MEA l

1.25 l UTE

-0.13 l I-L

Attachment to ICAN069806 Page 51 of127 Table 7 (cont)

"A" OTSG Upper Roll Ares Maws l

73 l

120 l

SEA l

1.21 l UTE

-0.34 l l

l 73 l

124 l

SEA l

1.25 l UTE

-0.30 l l

73 l

129 l

MEA l

1.39 l UTE

-0.24 l l

74 l

32 l

MEA l

0.74 l UTE

-0.18 l l

74 l

37 l

SEA l

1.35 l UTE

-0.16 l l

74 l

41 l

SEA l

1.14 l UTE

-0.15 l l

74 l

46 l

SEA l

2.38 l UTE

-0.26 l l

74 l

62 l

MEA l

1.51 l UTE

-0.28 l l

l 74 l

62 l

MEA l

1.55 l UTE

-0.31 l l

l 74 l

62 l

MEA l

1.71 l UTE

-0.31 l l

74 l

63 l

SEA l

1.10 l UTE

-0.18 l l

74 l

64 l

SEA l

0.73 l UTE

-0.37 l l

74 l

66 l

MEA l

0.89 l UTE

-0.27 l l

l 74 l

66 l

MEA l

1.58 l UTE

-0.27 l l

74 l

102 l

SEA l

1.28 l UTE

-0.21 l l

75 l

99 l

MEA l

1.14 l UTE

-0.33 l l

75 l

101 l

SEA l

1.07 lUTE

-0.49 l l

75 l

103 l

MEA l

1.39 l UTE

-0.31 l l

l 75 l

115 l

MEA l

1.24 l UTE

-0.28 l l

75 l

119 l

SEA l

1.46 l UTE

-0.29 l l

75 l

120 l

SEA l

2.14 l UTE

-0.23 l l

l 75 l

121 l

MEA l

1.93 l UTE

-0.64 l l

l 75 l

125 l

SEA l

1.52 l UTE

-0.37 l l

l 76 l

118 l

SEA l

1.83 l UTE

-0.28 ]

l 76 l

120 l

MEA l

1.98 l UTE

-0.20 l l

76 l

123 l

MEA l

2.59 l UTE

-0.38 l l

77 l

65 l

SEA l

0.55 l UTE

-0.33 l l

77 l

68 l

MEA l

1.55 l UTE

-0.35 l l

77 l

71 l

MEA l

1.26 l UTE

-0.38 l l

77 l

75 l

SEA l

0.50 l UTE

-0.26 l l

l 77 l

110 l

MEA l

1.10 l UTE

-0.12 l l

l 77 l

119 l

SEA l

1.53 l UTE

-0.23 l L

l 77 l

120 l

SEA l

1.77 l UTE

-0.13 l l

77 l

121 l

SEA l

1.12 l UTE

-0.14 l l

77 l

126 l

SEA l

1.39 l UTE

-0.37 l l

78 l

69 l

SEA l

1.55 l UTE

-0.19 l l

78 l

119 l

SEA l

1.95 l UTE

-0.22 l l

78 l

122 l

MEA l

1.65 l UTE

-0.15 l l

Attachment to ICAN069806 Page 52 of127 Table 7 (coat)

"A" OTSG Upper Rou Area Fisws l

79 l

13 l

SEA l

0.60 l UTE

-0.32 l l

79 l

14 l

SEA l

0.86 l UTE

-0.33 l l

79 l

16 l

MEA l

1.68 l UTE

-0.40 l l

79 l

16 l

MVI l

0.46 l UTE

-2.57 l l

79 l

16 l

MVI l

1.2 l UTE

-2.57 l l

79 l

16 l

MVI l

0.67 l UTE

-2.57 l l

79 l

17 l

MEA l

-2.60 l UTE

-0.42 l l

79 l

19 l

SEA l

2.20 l UTE

-0.34 l l

79-l 31 l

SEA

]

0.91-l UTE

-0.44 l -

l 79 l

46 l

MEA l

2.94 l UTE

-0.22 l l

79 l

47 l

MEA l

1.74 l UTE

-0.30 l l

79 l

74 l

MEA l

1.43 l UTE

-0.21 l -

l 79 l

123 l

MEA l

2.12 l UTE

-0.12 l l

79 l

124 l

MEA l

1.14 l UTE

-0.17 l l

l 79 l

130 l

MEA l

1.39 l UTE

-0.19 l l

l 80 l

22 l

SEA l

0.90 l UTE

-0.32 l l

l 80 l

27 l

SEA l

1.30 l UTE

-0.21 l l

l 80 l

43 l

SEA l

2.12 l UTE

-0.29 l

~l l

80 l

45 l

SEA l

2.25 l UTE

-0.27 l l

80 l

49 l

SEA 2.31 l UTE

-0.28 l l

80 l

51 l

SEA 2.76 l UTE

-0.30 l l

l80 l

59 l

SEA 1.46 l UTE

-0.15 l 80 l

61 l-SVI 2.%

l UTE

-3.06 l l

80 l

68 l

SAI 0.54 l UTE

-1.43 l l

80 l

72 l

SEA 1.15 l UTE

-0.19 l l

80 l

75 l

SEA 1.07 l UTE

-0.11l l

80 l

78 l

SEA 1.12 l UTE

-0.30 l l

80 l

124 l

MEA 1.56 l UTE

-0.20 l l

80 l

125 l

MEA 1.75 l UTE

-0.14 l l

80-l 126 l

MEA 2.17 l UTE

-0.37 l l

80 l

127 l

MEA 1.66 l UTE

-0.13 l l

80 l

128 l

SEA 0.97 l UTE

-0.34 l l

80 l

131 l

MEA 2.48 l UTE

-0.42 l.

t l

81 l

17 l

SEA 1.93 l UTE

-0.26 l l

81 l

47 l

SEA 1.54 l UTE

-0.30 l l

81 l

48 l

SEA 2.23 l UTE

-0.18 l l

81-l 49 l

SAI 0.75 l UTS

+0.83 l l

81 l

76 l

SEA 0.99 l UTE

-0.25 l

Attachment to ICAN069806 Page 53 of127 Table 7 (cont)

"A" OTSG Upper Roll Area Flaws

-0.21 81 l

85 l

SEA l

1.37 l UTE

-0.21 i

82 l

13 l

SEA l

0.62 l UTE

-0.24 82 l

21 l

MEA l

1.25 l UTE

-0.29 82 l

22 l

MEA l

1.54 l UTE

-0.31 I

82 l

23 l

SEA l

1.78 l UTE

-0.27 82 l

27 l

MEA l

0.66 l UTE

-0.24 I

82 l

37 l

SEA l

0.65 l UTE

-0.28 82 l

45 l

MEA l

1.04 l UTE

-0.31 82 l

51 l

MEA l

1.04 l UTE

-0.24 82 l

52 l

SEA l

0.93 l UTE

-0.27 82 l

67 l

MEA l

0.66 l UTE

-0.23 82 l

67 l

MEA l

1.34 l UTE

-0.25 82 l

77 l

SEA l

1.06 l UTE

-0.24 l

82 l

127 l

MEA l

1.08 l UTE

-0.26 l

83 l

15 l

SEA l

2.79 l UTE

-0.22 j

83 l

15 l

SEA l

2.49 l UTE

-0.26 l

83 l

16 l

SEA l

2.39 l UTE

-0.24 83 l

17 l

SEA l

2.11 l UTE

-0.29 83 l

20 l

SEA l

1.69 l UTE

-0.27 83 l

23 l

SEA l

0.82 l UTE

-0.28 83 l

49 l

SEA l

1.12 l UTE

-0.26 l

83 l

52 l

SEA l

1.84 l UTE

-0.24 83 l

53 l

SEA l

1.73 l UTE

-0.16 83 l

54 l

SEA l

1.44 l UTE

-0.25 83 l

75 l

SEA l

1.23 l UTE

-0.24 I

83 l

77 l

SEA l

0.67 l UTE

-0.33 83 l

115 l

SEA l

1.06 l UTE

-0.06 84 l

19 l

SEA l

1.51 l UTE

-0.27 84 l

26 l

SEA l

3.31 l UTE

-0.37 84 l

28 l

SEA l

0.83 l UTE

-0.27 84 l

54 l

SEA l

1.55 l UTE

-0.27 84 l

67 l

SAI l

1.31 l UTE

-1.65 l

84 l

106 l

SEA l

0.94 l UTE

-0.28 l

84 l

131 l

SEA l

0.98 l UTE

-0.26 1

85 l

15 l

MEA l

1.31 l UTE

-0.26 85 l

23 l

SCI l

0.19 I UTE

-1.92 85 l

23 l

SCI l

0.19 UTE

-1.92 85 l

47 l

SEA l

2.55 UTE

-0.29 l

Attachment to ICAN069806 Page 54 of127 Table 7 (cont)

"A" OTSG Upper Roll Area Maws 1

l 85 l

68 SEA l

1.00 l UTE

-0.22 l

85 l

73 SEA l

1.54 l UTE

-0.21 l

85 l

74 MEA l

1.04 l UTE

-0.25 l

85 l

75 SEA l

1.17 l UTE

-0.22 l

85 l

76 SEA l

1.32 l UTE

-0.28 l

85 l

95 SEA l

0.92 l UTE

-0.28 l

85 l

98 SEA l

0.97 l UTE

-0.14 l

85 l

105 SEA l

1.42 l UTE

-0.23 l

86 l

6 SEA l

1.43 l UTE

-0.19 l

86 l

7 SEA l

1.39 l UTE

-0.25 l

86 l

16 MEA l

1.62 l UTE

-0.33 l

86 l

47 SEA l

1.35 l UTE

-0.30 l

86 l

54 SEA l

2.23 l UTE

-0.11 l

86 l

64 SVI l

0.35 l UTE

-2.20 l

86 l

68 SEA l

1.45 l UTE

-0.20 l

86 l

75 SEA l

1.46 l UTE

-0.31 l

86 l

80 SEA l

1.50 l UTE

-0.22 l

86 l

83 SEA l

0.90 l UTE

-0.29 l

86 l

85 MEA l

2.69 l UTE

-0.34 l

86 l

86 MEA l

1.35 l UTE

-0.17 l

86 l

95 SEA l

1.40 l UTE

-0.19 l

86 l

106 MEA l

1.98 l UTE

-0.39 l

86 l

108 SVI l

0.62 l UTE

-1.60 l

86 l

113 SEA l

3.25 l UTE

-0.20 l

86 l

115 SEA l

0.83 l UTE

-0.18 l

86 l

122 MEA l

0.55 l UTE

-0.17

[

86 l

123 MEA l

1.51 l UTE

-0.34 l

86 l

126 MEA l

2.03 l UTE

-0.13 l

87 l

5 MEA l

2.06 l UTE

-1.62 l

87 l

7 MEA l

1.34 l UTE

-0.21 l

87 l

8 SEA l

1.33 l UTE

-0.44 l

87 l

14 MEA l

1.77 l UTE

-0.25 l

87 l

15 SEA l

0.60 l UTE

-0.35 l

87 l

16 SEA l

1.67 l UTE

-0.20 l

87 l

31 SAI l

0.55 l UTE

-1.78 l

87 l

42 SEA l

1.09 l UTE

-0.31 l

87 l

51 MEA l

1.54 l UTE

-0.28 l

87 l

53 SEA l

1.87 l UTE

-0.30

Attachment to ICAN069806 Page 55 of127 Table 7 (cont)

"A" OTSG Upper Roll Area Maws UTE

-0.18 l

87 l

80 l

MEA l

1.88 UTE

-0.28 l

87 l

80 l

MEA l

2.16 UTE

-0.38 l

87 l

82 l

SEA l

0.97 UTE

-0.15 l

87 l

83 l

SEA l

1.50 UTE

-0.21 l

87 l

85 l

MEA l

1.38 UTE

-0.16 l

87 l

94 l

MEA l

1.33 UTE

-0.21 l

87 l

98 l

MEA l

1.26 UTE

-0.28 l

87 l

105 l

SEA l

2.53 UTE

-0.31 l _ 87 l

106 l

SEA l

1.08 UTE

-0.19 l

88 l

7 l

MEA l

2.25 UTE

-0.50 '

l 88 l

8 l

MEA l

1.74 UTE

-0.12 l

88 l

11 l

SEA l

1.14 UTE

-0.29 l

88 l

13 l

SEA l

1.32 UTE

-0.26 l

88 l

15 l

SEA l

1.21 UTE

-0.25 l

88 l

16 l

SEA l

1.93 UTE

-0.21 l

88 l

45 l

MEA l

1.05 UTE

-0.20 l

88 l

46 l

SEA l

1.59 UTE

-0.23 l

88 l

74 l

SEA l

1.97 UTE

-0.30 l

88 l

102 l

SEA l

0.99 UTE

-0.20 l

88 l

106 l

SEA l

1.29 UTE

-0.19 l

89 l

8 l

MEA l

0.75 UTE

-0.19 l

89 l

9 l

MEA l

1.57 UTE

-0.39 l

89 l

14 SEA l

0.94 UTE

-0.20 l

89 l

15 l

SEA l

0.88 UTE

-0.25 l

89 l

16 l

MEA l

1.09 UTE

-0.21 l

89 l

18 l

SEA l

1.07 UTE

-0.22 l

89 l

19 l

SEA l

1.22 UTE

-0.26 l

89 l

47 l

MEA l

1.19 UTE

-0.23 l

89 l

52 l

MEA l

2.47 UTE

-0.19 l

89 l

54 l

sal l

0.49 UTE

-1.80 l

89 l

98 l

MEA l

1.20 UTE

-0.12 l

89 l

104 l

SEA l

2.09 UTE

-0.20 l

89 l

107 l

SEA l

1.44 UTE

-0.22 l

89 l

114 l

SEA l

0.82 UTE

-0.23 l

89 l

130 l

SEA l

1.40 UTE 4.26 l

90 l

4 l

SEA l

1.33 UTE

-0.18

~

l 90 l

7 l

SEA l

1.39 UTE

-0.17 l

90 l

8 l

MEA l

3.07 UTE

-0.41

Attachment to 1CANM9806 Page 56 of127 Table 7 (cont)

"A" OTSG Upper Roll Area Flaws

-0.28 l

90 l

15 l

MEA 2.46 l UTE

-0.22 1

90 l

29 l

SAI 0.48 l UTE

-2.15 l

90 l

45 l

MEA 1.23 l UTE

-0.42 l

90 l

54 l

SEA 0.99 l UTE

-0.25 l

90 l

103 l

SEA 1.37 l UTE

-0.22 l

91 l

1 l

MAI 0.42 l UTE

-1.50 l

91 l

4 l

MEA 1.47 l UTE

-0.18 l

91 l

8 l

MEA 2.28 l UTE

-0.20 l

91 l

13 l

MEA 1.73 l UTE

-0.22 l

91 l

14 l

MEA 1.29 l UTE

-0.25 l

91 l

16 l

MEA 2.00 l UTE

-0.20 l

91 l

17 l

SEA 1.00 l UTE

-0.20 l

91 l

18 l

SEA 1.22 l UTE

-0.22 l

91 l

25 l

SEA 2.04 l UTE

-0.30 l

91 l

45 l

SEA 1.51 l UTE

-0.29 l

91 l

87 l

MEA 1.03 l UTE

-0.20 l

91 l

115 l

SEA 1.35 l UTE

-0.36 l

92 l

1 l

SAI 1.52 l UTE

-1.38 l

92 l

5 l

MEA 2.14 l UTE

-0.20 l

92 l

6 l

MEA 1.60 l UTE

-0.22 l

92 l

7 l

SEA 1.49 l UTE

-0.19 l

92 l

8 l

SEA 0.75 l UTE

-0.22 l

92 l

9 l

SEA 1.37 l UTE

-0.21 l

92 l

10 l

SAI 0.58 l UTE

-2.44 l

92 l

12 l

SEA 0.83 l UTE

-0.21 l

92 l

14 l

SEA 1.03 l UTE

-0.19 l

92 l

18 l

SAI 0.61 l UTE

-2.42 l

92 l

25 l

MEA 3.07 l UTE

-0.25 l

92 l

30 l

SAI 0.48 l UTE

-1.81 l

92 l

39 l

SEA 0.63 l UTE

-0.41

( 92 l

51 l

SEA 1.26 l UTE

-0.25 l

92 l

74 l

SEA 1.02 l UTE

-0.35 l

92 l

113 l

SEA 1.60 l UTE

-0.16 l

92 l

114 l

SEA 1.02 l UTE

-0.26 l

92 l

115 l

SEA 1.80 l UTE

-0.29 l

92 l

116 l

MEA 1.62 l UTE

-0.24 l

92 l

118 l

MEA 1.98 l UTE

-0.24

)

l 92 l

123 l

SEA 0.98 l UTE

-0.20 i

Attachment to 1CAN069806 Page 57 Cf127 Table 7 (cont)

"A" OTSG Upper Roll Area Maws l

93 l

14 l

MEA l

1.61 l UTE

-0.10 l

]

l 93 l

32 l

SEA l

1.25 l UTE

-0.17 l l

93 l

44 l

MEA l

0.60 l UTE

-0.33 l l

93 l

102 l

MEA l

1.69 l UTE

-0.22 l l

93 l

107 l

SAI l

0.8 l UTE

-1.58 l

.1 l

93 l

109 l

SAI l

0.71 l UTE

-1.72 l j

l 93 l

110 l

SEA l

1.84 l UTE

-0.22 l l

93 l

111 l

MEA l

1.43 l UTE

-0.23 l l

l 93 l

112 l

SEA l

0.85 l UTE

-0.25 l l

93 l

113 l

SAI l

0.6 l UTE

-1.45 l l

94 l

1 l

SAI l

0.86 l UTE

-1.11 l l

94 l

5 l

SEA l

2.01 l UTE

-0.24 l l

l 94 l

5 l

SVI l

0.35 l UTE

-1.80 l l

94 l

7 l

SEA l

1.61 l UTE

-0.26 l l

94 l

14 l

hEA l

1.63 l UTE

-0.22 l l

94 l

34 l

SEA l

1.28 l UTE

-0.22 l l

94 l

42 l

SAI l

2.42 l UTE

-2.00 l l

94 l

43 l

SEA l

1.04 l UTE

-0.54 l l

94 l

46 l

MEA l

1.37 l UTE

-0.27 l l

94 l

66 l

SAI l

0.68 l UTE

-1.75 l l

94 l

73 l

SEA l

1.55 l UTE

-0.10 l l

94 l

93 l

SEA l

1.10 l UTE

-0.11l l

94 l

113 l

SEA l

0.93 l UTE

-0.22 l l

94 l

116 l

SEA l

0.90 l UTE

-0.20 l l

95 l

7 l

MEA l

1.54 l UTE

-0.28 l l

95 l

11 l

SEA l

2.52 l UTE

-0.24 l l

95 l

14 l

MEA l

1.69 l UTE

-0.26 l l

95 l

17 l

SEA l

1.21 l UTE

-0.12 l l

95 l

23 l

SEA l

0.79 l UTE

-0.13 l l

95 l

35 l

SEA l

1.57 l UTE

-0.36 l l

95 l

45 l

SEA l

2.14 l UTE

-0.39 l l

95 l

71 l

SEA l

2.18 l UTE

-0.18 l l

95 l

73 l

SEA l

1.65 l UTE

-0.10 l l

95 l

113 l

SEA l

1.90 l UTE

-0.27 l l

l 95 l

115 l

SEA l

1.07 l UTE

-0.28 l l

96 l

3 l

SEA l

1.35 l UTE

-0.23 l l

96 l

4 l

SEA l

1.00 l UTE

-0.14 l l

96 l

5 l

MEA l

2.94 l UTE

-0.25 l

Attachment to 1CANM9806 l

Page 58 cf127 l

Table 7 (cont)

"A" OTSG Upper Roll Area Maws l

l 7

l SAI l

0.53 l UTE

-2.52 l l

31 l

MEA l

2.25 l UTE

-0.22 l l

32 l

MEA l

1.40 l UTE

-0.32 l l

39 l

SEA l

1.71 l UTE

-0.27 l l

44 l

SEA l

2.15 l UTE

-0.27 l l

72 l

SEA l

2.03 l UTE

-0.10 l l

73 l

SEA l

2.50 l UTE

-0.22 l l

88 l

SEA l

1.32 l UTE

-0.14 l l

99 l

SEA l

1.90 l UTE

-0.18 l

(

l 108 l

MEA l

3.05 l UTE

-0.28 l l

113 l

SEA l

1.41 l UTE

-0.17 l l

(

96 l

115 l

SEA l

0.78 l UTE

-0.20 l l

96 l

116 l

MAI l

0.68 l UTE

-1.68 l l

118 l

MEA l

1.57 l UTE

-0.23 l l

122 l

SVI l

0.62 l UTE

-0.81 l l

127 l

SEA l

3.10 l UTE

-0.44 l 97 l

6 l

SEA l

2.58 l UTE

-0.24 l l

97 l

13 l

SEA l

1.87 l UTE

-0.29 l l

97 l

14 l

MEA l

3.63 l UTE

-0.25 l 97 l

35 l

SEA l

1.44 l UTE

-0.26 l 97 l

45 l

SEA l

1.94 l UTE

-0.27 l 97 l

61 l

SEA l

1.62 l UTE

-0.17 l 97 l

72 l

SEA l

1.98 l UTE

-0.14 l I

97 l

73 l

MEA l

0.83 l UTE

-0.15 l 97 l

77 l

MEA l

0.76 l UTE

-0.20 l l

97 l

77 l

MEA l

0.56 l UTE

-0.21 l I

97 l

102 l

SEA l

1.48 l UTE

-0.14 l l

98 l

5 l

SEA l

1.31 l UTE

-0.27 l i

l 98 l

7 l

MEA l

2.37 l UTE

-0.23 l l

98 l

11 l

MEA l

1.79

.l UTE

-0.28 l 98 l

32 l

SEA l

0.90 l UTE

-0.18 l l

l 98 l

36 l

SEA l

2.52 l UTE

-0.13 l 98 l

45 l

SEA l

0.73 l UTE

-0.16 l 98 l

62 l

MEA l

1.62 l UTE

-0.16 l l

98 l

69 l

MEA l

1.63 l UTE

-0.12 l l

98 l

88 l

SEA l

3.03 l UTE

-0.13 l 98 l

115 l

SAI l

0.67 l UTE

-1.47 l 98 l

120 l

SAI l

0.62 l UTE

-1.31 l 1

Attachment ts ICAN069806 Page 59sf127 Table 7 (coat)

"A" OTSG Upper Roll Area Flaws l

99 l

5 l

MEA l

1.20 l UTE

-0.28 l l

99 l

6 l

SEA l

2.08 l UTE

-0.23 l l

99 l

22 l

SEA l

1.23 l UTE

-0.29 l l

99 l

23 l

SEA l

1.49 l UTE

-0.24 l l

99 l

24 l

SEA l

0.63 l UTE

-0.33 l l

99 l

24 l

SVI l

0.23 l UTE

-4.20 l l

99 l

27 l

MEA l

1.57 l UTE

-0.24 l l

99 l

39 l

' SEA l

0.68 l UTE

-0.37 l i

l 99 l

44 l

MEA l

1.70 l UTE

-0.26 l l

99 l

45 l

MEA l

0.91 l UTE

-0.27 l l

99 l

66 l

MEA l

1.51 l UTE

-0.27 l l

l 99 l

68 l

MEA l

2.32 l UTE

-0.22 l l

l 99 l

102 l

SEA l

1.84 l UTE

-0.15 l l

99 l

107 l

SEA l

1.22 l UTE

-0.29 l I

l 99 l

114 l

MEA l

1.44 l UTE

-0.15 l l

99 l

115 l

MAI l

1.03 l UTE

-1.75 l l

100 l

4 l

SEA l

0.98 l UTE

-0.29 l l

l 100 l

6 l

MEA l

1.13 l UTE

-0.19 l l

100 l

8 l

MEA l

1.52 l UTE

-0.24 l l

100 l

11 l

SEA l

0.66 l UTE

-0.31 l l

100 l

21 l

SAI l

0.57 l UTE

-2.17 l l

100 l

28 l

SAI l

1.51 l UTE

-1.55 l l

100 l

44 l

MEA l

1.15 l UTE

-0.25 l l

100 l

56 l

SEA l

1.37 l UTE

-0.22 l l

100 l

60 l

SEA l

0.95 l UTE

-0.20 l l

100 l

61 l

SEA l

0.47 l UTE

-0.08 l l

100 l

63 l

SEA l

1.24 l UTE

-0.16 l l

100 l

75 l

SEA l

1.12 l UTE

-0.17 l l

101 l

5 l

MEA l

1.78 l UTE

-0.51 l l

101 l

13 l

SEA l

1.30 l UTE

-0.25 l l

101 l

22 l

SEA l

0.55 l UTE

-0.26 l l

101 l

23 l

SEA l

0.%

l UTE

-0.31 l l

101 l

25 l

SEA l

1.58 l UTE

-0.22 l l

101 l

54 l

MEA l

1.56 l UTE

-0.20 l l

101 l

55 l

SEA l

2.61 l UTE

-0.15 l l

101 l

63 l

SEA l

0.76 l UTE

-0.15 l l

101 l

68-l SEA l

1.97 l UTE

-0.30 l l

101 l

79 l

SVI l

1.%

l UTE

-2.09 l

Attachment to ICAN069806 t

Page 60 cf127 Table 7 (comt)

"A" OTSG Upper Roll Area Flaws 1

l 101 l

122 l

SAI l

0.86 l UTE

-1.11 l l

101 l

124 l

SAI l

0.92 l UTE

-1.07 l l

102 l

3 l

SAI l

1.61 l UTE

-1.53 l l

102 l

40 l

SEA l

1.02 l UTE

-0.20 l l

102 l

54 l

SEA l

1.61 l UTE

-0.13 l l

102 l

55 l

MEA l

2.01 l UTE

-0.18 l l

102 l

61 l

SAI l

0.33 l UTE

-1.93 l j

l 102 l

62 l

SEA l

0.92 l UTE

-0.16 l l

102 l

76 l

MEA l

1.39 l UTE

-0.17 l l

102 l

80 l

SEA l

1.28 l UTE

-0.14 l l-102 l

100 l

SEA l

1.22 l UTE

-0.25 l l

102 l

101 l

SEA l

2.62 l UTE

-0.19 l l

102 l

112 l

SEA l

1.03 l UTE

-0.16 l l

103 l

4 l

SAI l

0.78 l UTE

-2.42 l l

103 5

l SEA l

1.16 l UTE

-0.23 l l

103 27 l

SEA l

0.59 l UTE

-0.27 l l

103 33 l

MEA l

1.65 l UTE

-0.25 l l

103 44 l

SEA l

1.20 l UTE

-0.23 l l

103 76 l

SEA l

1.27 l UTE

-0.28 l l

103 77 l

SEA l

1.80 l UTE

-0.09 l l

103 108 l

SEA l

1.17 l UTE

-0.27 l l

103 113 l

MEA l

2.50 l UTE

-0.11 l l

103 113 l

MEA l

2.50 l UTE

-0.11 l l

104 20 l

SEA l

2.05 l UTE

-1.6]7

-0.2 l

104 22 l

MAI l

1.34 l UTE 7l l

104 29 l

SEA l

1.43 l UTE

-0.24 l l

104 41 l

MEA l

6.66 l UTE

-0.34 l l

104 60 l

SEA l

1.91 l UTE

-0.19 l l

l 104 74 l

SEA l

1.88 l UTE

-0.17 l l

l 104 76 l

SEA l

1.09 l UTE

-0.14 l l

104 78 l

SEA l

1.27 l UTE

-0.26 l l

104 113 l

SEA l

1.89 l UTE

-0.14 l

]

l 105 1

l SAI l

0.88 l UTE

-1.80 l J

l 105 6

l SEA l

1.08 l UTE

-0.27 l l

l 105 9

l SEA l

1.19 l UTE

-0.21 l l

105 10 l

MEA l

1.43 l UTE

-0.24 l l

105 11 l

SEA l

1.17 l UTE

-0.23 l l

105 12 l

SEA l~

2.17 l UTE

-0.29 j l

Attachment to 1CAN069806 Page 61 cf127 Table 7 (coat)

"A" OTSG Upper Roll Area Flaws l

l 105 l

35 l

SEA l

1.41 l UTE

-0.26 l l

105 l

43 l

SEA l

4.36 l UTE

-0.22 l l

l 105 l

50 l

SEA l

J.70 l UTE

-0.29 l l

105 l

64 l

SEA l

1.22 l UTE

-0.15 l l

105 l

~74 l

SEA l

1.35 l UTE

-0.16 l l

105 l

114 l

SEA l

0.59 l UTE

-0.23 l l

105 l

117 l

SEA l

0.74 l UTE

-0.11 l l

106 l

1 l

sal l

0.82 l UTE

-1.78 l l

106 l

2 l

SAI l

0.8 l UTE

-1.74 l l

106 l

7 l

SEA l

1.59 l UTE

-0.26 l l

106 l

19 l

MEA l

2.11 l UTE

-0.27 l l

106 l

21 l

SEA l

1.29 l UTE

-0.14 l l

106 l

32 l

SEA l

1.32 l UTE

-0.18 l l

106 l

59 l

SEA l

1.26 l UTE

-0.14 l l

106 l

61 l

SEA l

2.28 l UTE

-0.11 l l

106 l

61 l

SEA l

1.99 l UTE

-0.14 l 1

l 106 l

71 l

SEA l

0.%

l UTE

-0.13 l l

106 l

77 l

SEA l

1.46 l UTE

-0.19 l l

106 l

80 l

SEA l

1.50 l UTE

-0.20 l l

106 l

98 l

SEA i

0.82 l UTE

-0.48 l l

106 l

99 l

SEA

~1.10 l UTE

-0.18 l l

106 l

104 l

MEA 1.44 l UTE

-0.16 l i

l 106 l

109 l

SEA 1.79 l UTE

-0.16 l l

107 l

6 l

MEA 1.17 l UTE

-0.21 l l

107 l

10 l

SEA 1.33 l UTE

-0.19 l l

l 107 l

21 l

SEA 0.92 l UTE

-0.25 l l

l 107 l

42 l

SEA 2.64 l UTE

-0.25 l l

107 l

66 l

SEA 1.24 l UTE

-0.33 l l

107 l

73 l

SEA 1.87 l UTE

-0.19 l l

107 l

74 l

SEA 1.13 l UTE

-0.22 l l

107 l

119 l

SEA 0.85 l UTE

-0.19 l l

108 l

6 l

SAI 0.41 l UTE

-1.52 l l

108 l

31 l

SEA 1.01 l UTE

-0.16 l l

108 l

41 l

SEA 2.50 l UTE

-0.43 l l

108 l

74 l

SEA 0.55 l UTE

-0.24 l l

108 l

81 l

SEA 1.15 l UTE

-0.29 l l

108 l

105 l

MEA 1.28 l UTE

-0.13 l l

108 l

107 l

MEA 1.90 l UTE

-0.12 l

[

Attachment to ICAN069806 Page 62 of127 Table 7 (coat)

"A" OTSG Upper Roll Area Maws l

109 l

3 l

SEA l

0.74 l UTE

-0.23 l l

109 l

5 l

SAI l

0.27 l UTE

-1.45 l l

109 l

18 l

SEA l

1.40 l UTE

-0.26 l l

109 l

22 l

-MEA l

0.59 l UTE

-1.56 l l

109 l

36 l

MEA l

1.28 l UTE

-0.37 l l

109 l

38 l

MEA l

4.52 l UTE

-0.34 l l

109 l

41 l

MEA l

3.60 l UTE

+0.00 l l

109 l

59 l

SEA l

1.38 l UTE

-0.21 l l

109 l

72 l

MEA l

3.36 l UTE

-0.33 l l

109 l

76 l

SEA l

1.17 l UTE

-0.10 l l

109 l

78 l

SEA l

1.17 l UTE

-0.11 l l

109 l

84 l

SEA l

2.68 l UTE

-0.23 l l

109 l

87 l

MEA l

1.73 l UTE

-0.31 l l

110 l

18 l

SEA l

1.05 l UTE

-0.32 l l

110 l

19 l

SEA l

2.11 l UTE

-0.29 l l

110 l

34 l

SEA l

0.80 l UTE

-0.33 l l

110 l

40 l

SEA l

3.03 l UTE

-0.29 l l

110 l

71 l

SEA l

1.77-l UTE

-0.24 l l

110 l

79 l

SEA l-2.30 l UTE

-0.30 l l

110 l

83 l

SEA l

0.84 l UTE

-0.33 l l

110 l

97 l

SEA l

1.49 l UTE

-0.24 l l

111 l

16 l

MEA l

0.87 l UTE

-0.42 l l

111 l

18 l

SEA l

0.98 l UTE

-0.19 l l

111 l

19 l

SAI l

0.24 l UTE

-1.47 l l

111 l

22 l

SEA l

0.86 l UTE

-0.23 l l

Ill l

29 l

SEA l

1.34 l UTE

-0.35 l l

111 l

40 l

SEA l

1.01 l UTE

-0.31 l l

111 l

63 l

SEA l

1.77 l UTE

-0.35 l l

111 l

64 l

SEA l

1.23 l UTE

-0.22 l l

111 l

70 l

SEA l

0.75 l UTE

-0.16 l l

111 l

73 l

SEA l

1.06 l UTE

-0.26 l l

l l

111 l

77 l

SEA l

2.52 l UTE

-0.28 l l

l 111 l

93 l

MEA l

0.92 l UTE

-0.27 l l

111 l

97 l

MEA l

1.84 l UTE

-0.30 l l

111 l

100 l

SEA l

0.58 l UTE

-0.47 l l

111 l

109 l

SEA l

0.60 l UTE

-0.16 l l

111 l

110 l

SEA l

1.84 l UTE

-0.29 l l

112 l

1 l

SEA l

4.13 l UTE

-0.29 l

Att chment to 1CAN069806 Page 63 of127 Table 7 (cont)

"A" OTSG Upper Roll Area Flaws UTE l

112 l

49 SEA l

1.97 UTE

-0.28 l l

112 l

64 MEA l

1.66 UTE

-0.24 l l

112 l

78 SEA l

2.85 UTE

-0.15 l l

112 l

80 SEA l

0.89 UTE

-0.22 l l

112 l

90 SEA l

1.13 UTE

-0.50 l l

112 l

103 SEA l

1.64 UTE

-0.15 l l

112 l

113 MEA l

2.26 UTE

-0.12 l l

113 l

1 SAI l

0.92 UTE

-1.19 l l

113 l

9 SAI l

1.23 UTE

-1.93 l l

113 l

39 SEA 1.53 UTE

-0.26 l l

113 l

63 MEA 1.75 UTE

-0.22 l l

113 l

77 SEA 1.12 UTE

-0.19 l l

113 l

80 SEA 1.78 UTE

-0.27 l l

113 l

97 SAI 0.84 UTE

-1.45 l l

113 l

110 MEA 2.21 UTE

-0.11 l l

114 l

1 SAI 1.33 UTE

-1.30 l l

114 l

19 SEA 1.29 UTE

-0.21 l l

114 l

38 MEA 2.12 UTE

-0.26 l l

114 l

39 SEA 0.93 UTE

-0.28 l l

114 l

42 SEA 1.49 UTE

-0.28 l l

114 l

44 SEA 1.15 UTE

-0.28 l l

114 l

103 SEA 1.19 UTE

-0.17 l l

115 l

1 MAI 0.45 UTE

-1.37 l l

115 l

17 SEA 2.82 UTE

-0.21 l l

115 l

17 SAI 0.58 UTE

-2.50 l l

115 l

25 SEA 1.11 UTE

-0.21 l l

115 l

28 MEA 2.10 UTE

-0.12 l l

115 l

29 SAI 0.73 UTE

-1.21 l l

115 l

31 SEA 1.10 UTE

-0.22 l l

115 l

33 SEA 1.59 UTE

-0.23 l l

115 l

36 MEA 4.94 UTE

-0.21 l l

115 l

38 hEA 0.88 UTE

-0.20 l l

.I15 l

39 SEA 1.60 UTE

-0.22 l l

115 l

63 MEA 2.25 UTE

-0.22 l l

115 l

63 SAI 0.58 UTE

-1.51 l l

115 l

67 SEA 1.13 UTE

-0.17 l l

115 l

68 MEA 1.73 UTE

-0.25 l l

115 l

70 SEA 1.54 UTE

-0.29 l

Attachment to 1CAN069806 Page 64 ef127 Tatde 7 (cost)

"A" OTSG Upper Rou Area Flaws l

115 l

85 l

SEA l

0.73 l UTE

-0.27 l l

115 l

87 l

SEA l

1.40 l UTE

-0.35 l l

116 l

2 l

MEA l

2.01 l UTE

-0.12 l l

116 l

15 l

SEA l

0.86 l UTE

-0.07 l l

116 l

17 l

SEA l

2.20 J.UTE

-0.13 l l

-116 l

21 l

SEA l

0.89 i UTE

-0.15 l

~

l 116 l

37 l

MEA l

3.82 UTE

-0.20 l l

116 l

38 l

MEA l

2.33 UTE

-0.25 l l

116 l

46 l

MEA l

2.59 UTE

-0.13 l l

116 l

62 l

MEA l

1.67

~

UTE

-0.21 l l

116 l

68 l

MEA l

1.91

~ UTE

-0.34 l l

116 l

69 l

MEA l

2.57 UTE

-0.20 l l

116 l

70 l

MEA l

1.23 UTE

-0.35 l l

116 l

71 l

MEA l

2.06 UTE

-0.21 l l

116 l

72 l

SEA l

1.47 UTE

-0.28 l l

116 l

87 l

SEA l

1.56 UTE

-0.30 l l

-116 l

101 l

SEA l

1.47 UTE

-0.35 l l

117 1

35 l

SEA l

0.95 UTE

-0.22 l l

l 117 l

36 l

SEA l

1.56 UTE-

-0.21 l l

117 l

39 l

SAI l

D.48 UTE

-1.21 l l

117 l

42 l

SEA l

1.52 UTE

-0.20 l l

l 117 l

60 l

MEA l

4.77 UTE

-0.22 l l

117 l

67 l

MEA l

1.37 UTE

-0.37 l l

118 l

11 l

MEA _

l 1.60 UTE

-0.13 l l

118 l

12 l

SEA l

1.41 UTE

-0.18 l l

118 l

13 l

MEA l

1.17 UTE

-0.14 l l

118 l

14 l

ME l

1.74 UTE

-0.23 l l

118 l

15 l

SEA l

2.12 UTE

-0.27 l l

118 l

24 l

MEA l

1.27 UTE

-0.14 l l

118 l

25 l

SEA l

1.09 UTE

-0.16 l l

118 l

29 l

SEA l

2.04 UTE

-0.17 l l

118 l

34 l

SEA l

0.93 UTE

-0.17 l l

118 l

56 l

SEA l

0.63 UTE

-0.19 l l-118 l

59 l

SEA l

2.08 UTE

-0.23 l l

118 l

64 l

SEA l

0.98 UTE

-0.18 l t

118 l

68 l

SEA l

0.92 UTE

-0.23 l l

118 l

75 l

SEA l

1.37 UTE

-0.27 l i

l 118 l

91 l

MEA l

1.85 UTE

-0.24 l l

Attachment to 1CAN069806 Page 65 of127 j

Table 7 (coat)

"A" OTSG Upper Rau Area Flaws l

118 l

98 l

SEA l

1.09 l UTE

-0.23 l l

118 l

100 l

MEA l

1.77 l UTE

-0.24 l l

119 l

11 l

SEA l

2.60 l UTE

-0.22 l l

119 l

16 l

MEA l

1.32 l UTE

-0.10 l l

119 l

20 l

MEA l

1.41 l UTE

-0.22_ l l

119 l

25 l

MEA

_l 2.37 I UTE

-0.28 l l

119 l

26 l

SEA l

1.45 l UTE

-0.25 l l

119 l

36 l

SEA l

1.50 l UTE

-0.29 l l

119 l

60 l

SEA l

0.86 l UTE

-0.18 l l

119 l

61 l

SEA l

1.50" l UTE 4).29 ]

l 119 l

72 l

MEA l

1.31 l UTE

-0.18 l l

119 l

74 l

SEA l _

l.13 l UTE

-0.28 l l

119 l

76 l

MEA l

1.54 l UTE

-0.25 l l

119 l

93 l

MEA l

1.91 l UTE

-0.19 l l

119 l

95 l

MEA l

1.44 l UTE

-0.17 l l

119 l

98 l

SEA l

1.62 l UTE

-0.19 l l

119 l

103 l

SEA l

2.36 l UTE

-0.29 l l

119 l

104 l

SEA l

1.87 l UTE

-0.17 l l

119 l

106 l

MEA l

1.71 l UTE

-0.29 l l

119 l

108 l

SEA l

1.01 l UTE

-0.28 l l

120 l

12 l

MEA l

1.93 l UTE

-0.16 l l

120 l

24 l

MEA l

2.10 l UTE

-0.29 l l

120 l

35 l

SEA l

1.45 l UTE

-0.27 l l

120 l

40 l

SEA l

1.66 l UTE

-0.21 l l

120 l

42 l

SEA l

2.48 l UTE

-0.22 l l

120 l

46 l

SEA l

1.85 l UTE

-0.25 l l

120 l

73 l

MEA l

1.93 l UTE

-0.19 l l

120 l

74 l

MEA l

1.70 l UTE

-0.21 l l

120 l

76 l

SEA l

1.52 l UTE

-0.18 l l

120 l

91 l

MEA l

1.50 l UTE

-0.27 l l

120 l

92 l

MEA l

2.01 l UTE

-0.19 l l

120 l

101 l

SEA l

0.85 l UTE

-0.59 l l

121 l

3 l

SEA l

1.07 l UTE

-0.10 l l

121 l

9 l

MEA l

5.12 l UTE

-0.15 l l

121 l

11 l

SEA l

1.55 l UTE

-0.17 l l

121 l

25 l

SEA l

1.00 l UTE

-0.25 l l

121-l 41 l

SEA l

1.78 l UTE 0.28 l l

l 121 l

45 l

SEA l

1.36 l UTE

-0.27 l

Attachment to 1CAN069806 Page 66 cf127 Table 7 (cont)

"A" OTSG Upper Roll Area Maws 121 121 l

66 l

SEA l

0.92 l UTE

-0.23 l 121 l

68 l

SEA l

1.65 l UTE

-0.23 l 121 l

71 l

SEA l

3.35 l UTE

-0.25 l 121 l

74 l

SEA l

1.24 l UTE

-0.18 l 121 l

78 l

SEA l

1.06 l UTE

-0.15 l 121 l

91 l

MEA l

2.08 l UTE

-0.22 l 121 l

94 l

SEA l

1.69 l UTE

-0.38 l 121 l

95 l

SEA l

1.89 l UTE

-0.24 l 121 l

98 l

SEA l

2.07 l UTE

-0.45 l 121 l

100 l

SEA l

2.08 l UTE

-0.44 l 122 l

9 l

MEA l

1.82 l UTE

-0.12 l 122 l

20 l

MEA l

2.60 l UTE

-0.26 l 122 21 l

SEA l

1.67 l UTE

-0.28 l 122 25 l

MEA l

0.99 l UTE

-0.27 l 122 26 l

MEA.

l 3.02 l UTE

-0.33 l l

122 27 l

MEA l

1.23 l UTE

-0.25 l 122 39 l

SEA l

l.09 l UTE

-0.26 l 122 40 l

SEA l_

1.61 l UTE

-0.29 l 122 41 l

SEA l

1.03 l UTE

-0.28 l 122 42 l

SEA l

0.70 l UTE

-0.24 l 122 43 l

SEA l

1.25 l UTE

-0.22 l 122 58 l

SEA l

1.38 l UTE

-0.13 l I

122 64 l

MEA l

1.47 l UTE

-0.21 l 122 69 l

SEA l

1.23 l UTE

-0.24 l 122 71 l

MEA l

2.54 l UTE

-0.20 l 122 72 l

MEA l

2.24 JUTE

+0.00 l 122 73 j

SEA

_l 0.85 l UTE

-0.20 l 122 91 l

SEA l

3.22 I UTE

-0.27 l 122 92 l

SEA l

2.32 l UTE

-0.26 l 122 95 l

SEA l

1.97 l UTE

-0.26 l 122 97 l

SEA l

2.29 l UTE

-0.38 l 122 98 l

SEA l

2.27 l UTE

-0.42 l 123 1

l SEA l

3.08 l UTE

-0.13 l 123 2

l SEA l

1.19 l UTE

-0.24 l 123 10 l

SEA l

3.83 l UTE

-0.40 l j

123 12 l

SEA l

0.74 l UTE

-0.53 l 123 19 l

MEA l

2.27 l UTE

-0.32 '

123 23 l

SEA l

1.13 l UTE

-0.26

_ - _ _ - _ - _ _ _ _ _ - _ - _ _ _ - _ _ - _ _ _ _ - _ _ _ _ - _ - _ _ _ _ _ _ _ _ - - _ _ _ _ _ - - _ - _ _ _ _ _ _ _ - _ _ _ _ _ _ = - _

Attachment to 1CAN069806 Page 67 cf127 Table 7 (cost)

"A" OTSG Upper Roll Area Flaws l

123 l

34 l

MEA l

5.45 l UTE

-0.21 l l

123 l

65 l

MEA l

1.63 l UTE

-0.24 l l

123 l

69 l

MEA l

1.18 l UTE

-0.22 l l

123 l

72 l

MEA l

1.43 l UTE

-0.14 l l

123 l

73 l

MEA l

1.67 l UTE

-0.23 l l

123 l

l SEA l

1.97 l UTE

-0.43 l l

123 l

98 l

SEA l

2.84 l UTE

-0.28 l l

123 l

100 l

MEA l

2.08 l UTE

-0.32 l l

123 l

101 l

SEA l

1.25 l UTE

-0.30 l l

123 l

104 l

SEA l

1.55 l UTE

-0.20 l l

123 l

104 l

SEA l

1.76 l UTE

-0.21 l l

124 l

1 l

SEA l

0.91 l UTE

-0.21 l l

124 l

7 l

MEA l

1.64 l UTE

-0.19 l l

124 l

10 l

SEA l

2.05 l UTE

-0.18 l l

l 124 l

11 l

MEA l

1.28 l UTE

-0.21 l l

124 l

26 l

SEA l

1.06 l UTE

-0.22 l l

124 l

27 l

SEA l

1.30 l UTE

-0.28 l l

124 l

31 l

MEA l

5.08 l UTE

-0.26 l l

124 l

61 l

SEA l

1.48 l UTE

-0.34' l l

124 l

63 l

SEA l

1.86 l UTE

-0.20 l l

124 l

64 l

SEA l

1.47 l UTE

-0.21 l l

l 124 l

67 l

MEA l

2.19 l UTE

-0.25 l l

l 124 l

70 l

SEA l

1.67 l UTE

-0.19 l l

124 l

71 l

MEA l

1.86 l UTE

-0.23 l l

124 l

72 l

SEA l

1.99 l UTE

-0.23 l l

l 124 l

73 l

SEA l

1.47 l UTE

-0.21 l i

l 124 l

82 l

MEA l

1.46 l UTE

-0.34 l l

124 l

82 l

SAI l

0.83 l UTE

-1.72 l l

124 l

89 l

MEA l

2.06 l UTE

-0.23__j l

124 l

90 l

MEA l

3.05 l UTE 0.25 l l

l 124 l

95 l

SEA l

1.54 l UTE

-0.37 l I

l l

124 l

97 l

SEA l

3.19 l UTE

-0.29 l l

l 125 l

25 l

SCI l

0.93 l UTE

-2.36 l l

125 l

25 l

SCI l

0.93 l UTE

-2.36 l l

125 l

29 l

MEA l

0.63 l UTE

-0.23 l l

125 l

31 l

MEA l

1.36 l UTE

-0.23 l l

125 l

32 l

MEA l

1.46 l UTE

-0.22 l l

125 l

34 l

SEA l

1.06 l UTE

-0.26 l l

I L_____________________

l

Attachment to ICAN069806 Page 68 of127 Table 7 (coat)

"A" OTSG Upper Rou Area Flaws 0.42 l

125 l

60 l

MEA l

0.84 l UTE 0.24 l

125 l

87 l

MEA l

2.24 l UTE 0.21 1

l 125 l

88 l

MEA l

1.02 l UTE 0.29 l

125 l

94 l

MEA l

1.93 l UTE 0.82 f

l 125 l

l MEA l

1.28 l UTE 0.30 l

125 l

97 l

MEA l

1.27 l UTE 0.55 l

125 l

98 l

SEA l

1.07 l UTE 0.31 l

126 l

9 l

SEA l

1.39 l UTE 0.28 l

126 l

10 l

MEA l

1.16 l UTE 0.24 l

126 l

11 l

MEA l

1.41 l UTE 0.25 l

126 l

27 l

SEA l

2.10 l UTE 0.29 l

126 l

30 l

SEA l

1.46 l UTE 0.28 l

126 l

31 l

SEA l

1.25 j UTE 0.23 l

126 l

41 l

SEA l

1.01 l UTE

-0.32 l

126 l

55 l

SEA l

2.28 l UTE 0.79 l

l 126 l

58 l

SEA l

1.21 l UTE 0.13 l

126 l

59 l

SEA l

2.65 l UTE 0.24 i

l 126 l

62 l

SEA l

1.01 l UTE 0.29 l

l 126 l

64 l

MEA l

1.30 l UTE 0.22 l

126 l

81 l

MEA l

1.36 l UTE 0.22 i

l 126 l

89 l

SEA l

1.80 l UTE 0.31 l

126 l

90 l

MEA l

1.68 l UTE 0.51 l

126 l

94 l

SEA l

2.63 l UTE 0.52 l

126 l

l MEA l

1.66 l UTE 0.31 l

126 l

99 l

MEA l

1.14 l UTE 0.35 l

127 l

20 l

MEA l

1.74 l UTE 0.31 l

127 l

24 l

MEA l

2.32 l UTE 0.21 l

127 l

25 l

SEA l

1.41 l UTE 0.24 l

127 l

30 l

MEA l

1.30 l UTE 0.21 I

l 127 l

31 l

SEA l

0.53 l UTE 0.27 l

l 127 l

38 l

MEA l

1.20 l UTE 0.25 l

127 l

39 l

SEA l

1.85 l UTE 0.25 l

l 127 l

41 l

SEA l

1.15 l UTE 0.26 l

127 l

54 l

MEA l

3.10 l UTE 0.22 l

127 l

55 l

SEA l

1.59 l UTE 0.21 l

127 l

60 l

SEA l

2.29 l UTE 0.19 l

127 l

61 l

MEA l

1.94 l UTE 0.25 l

127 l

62 l

MEA l

1.06 l UTE

-0.22

Attachment to

)

l 1CAN069806 Page 69 cf127 Table 7 (cost)

"A" OTSG Upper Rou Area Plaws l

127 l

67 l

SEA l

1.28 l UTE

-0.31 l

{

l 127 l

93 l

MEA l

1.53 l UTE

-0.23 l 1

l 127 l

94 l

MEA l

1.62 l UTE

-0.30 l l

127 l

l MEA l

3.08 l UTE

-0.30 l l

127 l

97 l

MEA l

2.23 l UTE

-0.16 l l

127 l

98 l

MEA l

3.05 l UTE

-0.13 l l

128 l

7 l

MEA l

2.54 l UTE

-0.17 l l

128 l

21 l

MEA l

1.46 l UTE

-0.24 l l

128 l

29 l

MEA l

0.80 l UTE

-0.27 l l

128 l

32 l

SEA l

1.68 l UTE

-0.21 l l

128 l

53 l

MEA l

2.47 l UTE

-0.21 l l

128 l

59 l

SEA l

1.22 l UTE

-0.22 l l

128 l

60 l

MEA l

2.73 l UTE

-0.46 l l

128 l

62 l

MEA l

1.81 l UTE

-0.44 l l

128 l

64 l

MEA l

1.86 l UTE

-0.38 l l

128 l

65 l

MEA l

0.63 l UTE

-0.20 l l

128 l

68 l

SEA l

1.80 l UTE

-0.34 l l

128 l

87 l

MEA l

1.65 l UTE

-0.35 l l

128 l

92 l

MEA l

2.37 l UTE

-0.35 l l

128 l

93 l

MEA l

1.78 l UTE

-0.24 l l

128 l

94 l

MEA l

1.20 l UTE

-0.31 l l

129 l

6 l

MEA l

0.97 l UTE

-0.24 l l

129 l

15 l

SEA l

1.47 l UTE

-0.35 l l

129 l

15 l

SAI l

0.68 l UTE

-1.71 l l

129 l

37 l

MEA l

1.99 l UTE

-0.49 l l

129 l

52 l

SEA l

4.34 l UTE

-0.58 l l

129 l

55 l

SEA l

1.57 l UTE

-0.28 l l

129 l

58 l

MEA l

1.53 l UTE

-0.37 l l

129 l

59 l

MEA l

2.61 l UTE

-0.21 l l

129 l

62 l

MEA l

1.86 l UTE

-0.38 l l

129 l

63 l

MEA l

1.92 l UTE

-0.21 l l

129 l

65 l

MEA l

1.59 l UTE

-0.21 l l

129 l

66 l

MEA l

2.90 l UTE

-0.38 l l

129 l

67 l

MEA l

1.56 l UTE

-0.22 l j

l 129 l

68 l

MEA l

1.95 l UTE

-0.25 l l

129 l

68 l

SAI l

0.52 l UTE

-1.13 l l

129 l

69 l

MEA l

2.41 l UTE

-0.24 l l

129 l

72 l

MEA l

0.81 l UTE

-0.39 l

Attachment to 1CAN069806 Page 70cf127 Table 7 (coat)

"A" OTSG Upper Roll Area Maws l

129 l

91 l

SAI l

0.38 l UTE

-1.66 l l

l 129 l

92 l

MEA l

0.99 l UTE

-0.26 l l

129 l

93 l

SEA l

0.94 j UTE

-0.31 l l

l 130 l

1 l

SEA l

1.72 l UTE

-0.10 l l

130 l

5 l

SEA l

0.71 l UTE

-0.43 l l

130 l

7 l

MEA l

2.42 l UTE

-0.27 l l

130 l

8 l

MEA l

1.16 l UTE

-0.46 l l

130 l

17 l

SEA l

1.16 l UTE

-0.18 l l

130 l

26 l

SEA l

1.22 l UTE

-0.13 l l

130 l

47 l

SEA l

0.55 l UTE

-0.30 l l

130 l

49 l

SEA l

1.25 l UTE

-0.13 l l

130 l

52 l

SEA l

1.81 l UTE

-0.32 l l

130 l

55 l

MEA l

2.55 l UTE

-0.26 l l

130 l

56 l

SEA l

1.63 l UTE

-0.19 l l

130 l

62 l

SEA l

0.56 l UTE

-0.21 l l

130 l

68 l

MEA l

1.00 l UTE

-0.21 l l

130 l

86 l

SEA l

0.90 l UTE

-0.25 l l

130 l

91 l

MEA l

1.85 l UTE

-0.28 l l

l 130 l

92 l

MEA l

3.58 l UTE

-0.28 l I

l 130 l

93 l

SAI l

0.76 l UTE

-1.59 l l

131 l

9 l

SEA l

0.37 l UTE

-0.11 l l

l 131 l

11 l

MEA l

2.11 l UTE

-0.19 l l

131 l

16 l

MEA l

0.94 l UTE

-0.19 l l

131 l

17 l

SEA l

2.42 l UTE

-0.17 l l

131 l

19 l

MEA l

2.29 l UTE

-0.18 l l

131 l

21 l

SEA l

1.60 l UTE

-0.17 l l

l 131 l

23 l

SEA l

1.34 l UTE

-0.15 l l

131 l

24 l

SEA l

1.31 l UTE

-0.13 l l

131 l

26 l

MEA l

1.04 l UTE

-0.14 l l

131 l

27 l

MEA l

0.82 l UTE

-0.14 l l

131 l

29 l

MEA l

1.02 l UTE

-0.18 l l

131 l

34 l

SEA l

1.25 l UTE

-0.14 l l

131 l

35 l

SEA l

0.53 l UTE

-0.16 l l

131 l

50 l

SEA l

3.55 l UTE

-0.18 l l

131 l

54 l

SEA l

1.97 l UTE

-0.30 l l

131 l

55 l

SEA

-l 4.28 l UTE

-0.29 l l

131 l

56 l

SEA l

2.22 l UTE

-0.16_ l l

131 l

64 l

SEA l

0.42 l UTE

-0.15 l

Attachment to ICAN069806 Page 71 cf127 Table 7 (cont)

"A" OTSG Upper Roll Area Flaws p.

l 131 l

90 l

MEA l

0.76 UTE

-0.30 l

132 l

4 l

SEA l

0.72 UTE

-0.31 l

132 l

5 l

MEA l

1.98 UTE

-0.32 l

132 l

6 l

SEA l

1.10 UTE

-0.36 l

l 132 l

15 l

MEA l

1.37 UTE

-0.24 l

l 132 l

17 l

SEA l

0.98 UTE

-0.20 l

132 l

25 l

MEA l

1.37 UTE

-0.27 l

132 l

35 l

MEA l

1.11 UTE

-0.13 l

132 l

38 l

SEA l

1.83 UTE

-0.16 l

132 l

43 l

MEA I

1.53 UTE

-0.17 l

132 l

45 l

SEA l

1.59 UTE

-0.14 l

132 l

48 l

MEA l

1.91 UTE

-0.26 l

132 l

51 l

SEA l

2.37 UTE

-0.31 l

132 l

52 l

SEA l

1.98 UTE

-0.31

)

l 132 l

53 l

SEA l

1.80 UTE

-0.34 l

132 l

77 l

SEA l

1.29 UTE

-0.29 l

133 l

9 l

SEA l

1.55 UTE

-0.32 l

133 l

15 l

SEA l

1.84 UTE

-0.37 l

133 l

20 l

MEA l

1.65 UTE

-0.31 l

133 l

21 l

SEA l

2.43 UTE

-0.41 l

133 l

23 l

MEA l

2.07 UTE

-0.40 l

133 l

25 l

SEA l

1.90 UTE

-0.32 l

133 l

40 l

SEA l

1.87 UTE

-0.50 l

133 l

42 l

SEA l

0.60 UTE

-0.49 l

133 l

48 l

SEA l

1.96 UTE

-0.31 l

l 133 l

51 l

SEA l

1.25 UTE

-0.27 l

l 133 l

53 l

SEA l

1.28 UTE

-0.36 l

133 l

70 l

MEA l

1.82 UTE

-0.19 l

133 l

80 l

SEA l

1.02 UTE

-0.23 l

134 l

1 l

SAI l

1 UTE

-1.25 l

134 l

2 l

SEA l

1.37 UTE

-0.32 l

134 l

10 l

SEA l

1.14 UTE

-0.24 l

134 l

13 l

SEA l

1.62 UTE

-0.27 l

134 l

14 l

SEA l

2.00 UTE

-0.30 l

134 l

14 l

SAI l

0.49 UTE

-1.24 l

134 l

15 l

SEA l

0.76 UTE

-0.25 l

134 l

20 l

MEA l

1.85 UTE

-0.26 l

134 l

23 l

MEA l

2.07 UTE

-0.31

Attachment to i

1CAN069806 Page 72 of127 Table 7 (cont) l "A" OTSG Upper Roll Area Flaws

-0.30 l

134 l

79 l

SEA l

2.94 l UTE

-0.26 l

135 l

7 l

MEA l

1.67 l UTE

-0.31 l

135 l

11 l

SAI l

0.41 l UTE

-1.42 l

135 l

13 l

SAI l

1.42 l UTE

-1.51 l

135 l

19 l

SEA l

1.36 l UTE

-0.29 l

135 l

20 l

MEA l

1.98 l UTE

-0.24 l

135 l

22 l

MEA l

2.28 l UTE

-0.24 l

135 l

23 l

SEA l

1.70 l UTE

-0.14 l

135 l

46 l

SEA l

3.86 l UTE

-0.26 l

135 l

47 l

MEA l

1.37 l UTE

-0.28 l

135 l

82 l

SEA l

0.66 l UTE

-0.23 l

l 136 l

9 l

MEA l

0.63 l UTE

-0.37 l

l 136 l

11 l

SEA l

1.54 l UTE

-0.35 l

136 l

19 l

SEA l

0.43 l UTE

-0.38 l

l 136 l

26 l

MEA l

1.31 l UTE

-0.25 l

136 l

46 l

MEA l

0.89 l UTE

-0.34 l

l 136 l

50 l

SEA l

1.07 l UTE

-0.09 l

l 137 l

4 l

MEA l

1.42 lUTE

-0.24 l

137 l

10 l

SEA l

0.81 l UTE

-0.55 l

137 l

17 l

SEA l

0.94 l UTE

-0.29 l

137 l

18 l

SEA l

0.98 l UTE

-0.25 l

l 137 l

20 l

MEA l

2.29 l UTE

-0.17 l

l 137 l

30 l

$EA l

0.78 l UTE

-0.33 l

l 137 l

38 l

MEA l

2.26 l UTE

-0.24 l

137 l

40 l

SEA l

1.20 l UTE

-0.27

)

l 137 l

45 l

SEA l

0.74 l UTE

-0.46 l

137 l

48 l

SEA l

1.71 l UTE

-0.17 l

137 l

50 l

SVI l

0.28 l UTE

-1.04 l

137 l

76 l

SEA l

0.83 l UTE

-0.13 l

138 l

8 l

SEA l

2.07 l UTE

-0.24 l

138 l

9 l

SAI l

0.71 l UTE

-2.03 l

138 l

20 l

SEA l

1.01 l UTE

-0. 19 l

138 l

23 l

SEA l

1.84 l UTE

-0.27 l

138 l

26 l

MEA l

1.74 l UTE

-0.23 l

138 l

27 l

SEA l

2.21 l UTE

-0.23

( 138 l

29 l

SEA l

2.03 l UTE

-0.23 l

138 l

30 l

SEA l

1.25 l UTE

-0.22 l

138 l

30 l

SAI l

0.67 l UTE

-1.67

Attachment ts 1CAN069806 Page 73 of127 Table 7 (cont)

"A" OTSG Upper Roll Area Maws l

UTE

-027 l

138 l

51 l

SEA l

1.18 UTE

-0.28 l

138 l

52 l

SEA l

1.38 UTE

-0.19 l

139 l _

26 l

SEA l

1.45 UTE

-0.21 l

139 l

28 l

SEA l

2.27 UTE

-0.21 l

139 l

37 l

SEA l

0.30 UTE

-0.25 l

139 j

55 l

SEA l

1.35 UTE

-0.22 l

139 l

73 l

SEA l

1.09 UTE

-0.16 l

140 l

24 l

MEA l

2.19 UTE

-0.26 l

140 l

28 l

MEA l

3.53 UTE

-0.29 l

140 l

31 l

SEA l

1.82 UTE

-0.30 l

140 l

'54 l

SEA l

1.92 UTE

-0.27 l

141 l

2 l

SAI l

0.56 UTE

-1.38 l

l 141_

l 10 l

SEA l

1.01 UTE

-0.28 l

l 141 l

14 l

MEA l

3.31 UTE

-0.26 i

l 141 l

24 l

SEA l

1.15 UTE

-0.27 l

141 l

25 l

SEA l

1.68 UTE

-0.32 l

141 l

26 l

MEA l

2.34 UTE

-0.22 l

141 l

46 l

SEA l

1.58 UTE

-0.22 l

141 l

56 l

SAI l

0.66 UTE

-1.28 142 l

10 l

MEA l

1.18 UTE

-0.29 i

142 l

17

-l MEA l

2.67 UTE

-0.19 142 l

22 l

MEA l

0.90 UTE

-0.28 142 l

24 l

SEA l

2.00 UTE

-0.28 142 l

28 l

MEA l

2.72 UTE

-0.26 142 l

35 l

SEA l

2.59 UTE

-0.20 142 l

45 l

SEA l

1.27 UTE

-0.13 I

142 l

48 l

SEA l

1.05 UTE

-0.29 142 l

51 l

SEA l

0.72 UTE

-0.22 143 l

3 l

SAI l

1.15 UTE

-2.37 143 l

9 l

SEA l

0.71 UTE

-0.27 143 l

17 l

SEA l

1.17 UTE

-0.20 143 l

18 l

SEA

.j 1.50 UTE

-0.33 l

143 l

19 l

MEA l

2.26 UTE

-0.12 143 l

21 l

SEA l

0.78 UTE

-0.23 143 l

23 l

MEA l

1.40 UTE

-0.14 l

143 l

38 l

MEA l

1.73 UTE

-0.30 144 l

15 l

SEA l

1.32 UTE

-0.20 144 l

17 l

SEA l

1.38 UTE

-0.14

Attachment ts 1CAN069806 Page 74 Cf127 Table 7 (cont)

"A" OTSG Upper Roll Area Flaws i.

l 144 l

42 l

SAI l

0.31 l UTE

-1.22 l

144 l

46 l

SAI l

0.66 l UTE

-1.37 I

l 144 l

47 l

SAI l

0.26 l UTE

-1.28 r

l 144 l

49 l

SEA l

1.77 l UTE

-0.22 l

l 145 l

7 l

SEA l

1.73 l UTE

-0.22 j

l l

145 l

17 l

SEA l

0.77 l UTE

-0.19 l

l 146 l

17 l

SEA l

0.43 l UTE

-0.21

~

l 146 l

43 l

MEA l

0.82 l UTE

-0.22 l

l 147 l

13 l

SEA l

1.24 l UTE

-0.32 l

147 l

15 l

SEA l

2.74 l UTE

-0.28 1

l 147 l

45 l

SEA l

2.44 l UTE

-0.23 l

l 148 l

37 l

SAI l

0.53 l UTE

-1.29 l

149 l

6 l

SEA l

1.27 l UTE

-0.29 l

149 l

19 l

SEA l

1.08 l UTE

-0.22 l

l 149 l

32 l

MAI l

0.25 l UTE

-1.23 l

l$0 l

2 l

SEA l

1.34 l UTE

-0.18 l

l l

150 l

5 l

SEA l

0.66 l UTE

-0.16 l

150 l

6 l

SEA l

1.00 l UTE

-0.23 l

150 l

22 l

SEA l

0.84 l UTE

-0.24 l

150 l

24 l

MEA l

0.72

_ l UTE

-0.20 l

150 l

26 l

SEA l

0.43 l UTE

-0.29 l

150 l

27 l

SAI l

1.19 l UTE

-2.59 l

l 151 l

1 l

SEA l

12.84 l UTE

-0.12 l

l 151 l

1 l

SEA l

5.58 l UTE

-D.13 l

151 l

2 l

SEA l

0.75 l ' UTE

-0.25 l

151 l

8 l

MEA l

2.71 l UTE

-0.28 l

151 l

16 l

SEA l

0.68 l UTE

-0.11 LTS = lower tube sheet M_A_I = multiple axial indications i g MEA = multiple end anomalies MVI = multiple volumetric indicatic as SAI = single axialindication SEA = single end anomaly SVI = single volumetric indication

Attachment to 1CAN069806 l

Page 75 cf127 Table 8 i

"B" OTSG Upper Roll Area Flaws l

-0.25 l

1 l

12 l

SEA l

1.81' l

UTE

-0.21 l

2 l

2 l

SEA l

1.35 l

UTE

-0.26 l

2 l

14 l

MEA l

2.95 l

UTE

-0.34 l

l 3

l 6

l SEA l

7.51 l

UTE

-0.16 l

3 l

17 l

MEA l

1.60 l

UTE

-0.21 l

3 l

31 l

SEA l

1.17 l

UTE

-0.28 l

l 4

l 1

l MEA l

3.98 l

UTE

-0.18 l

4 l

11 l

SEA 3.14 l

UTE

-0.06 l

4 l

16 l

SEA 1.14 l

UTE

-0.26 l

4 l

20 l

SEA 0.68 l

UTE

-0.29 l

4 l

21 l

SAI 0.46 l

UTE

-1.97 l

4 l

28 l

SEA 1.93 l

UTE

-0.22 l

l 5

l 1

l SEA 2.83 l

UTE

-0.18 l

5 l

6 l

MEA 1.49 l

UTE

-0.27 l

5 l

7 l

SEA 7.30 l

UTE

-0.21 l

5 l

22 l

SEA 2.11 l

UTE

-0.27 l

5 l

28 l

MEA 1.04 l

UTE

-0.23 l

5 l

45 l

MEA 0.60 l

UTE

-0.30 l

6 l

7 l

MEA 2.60 l

UTE

-0.27 l

6 l

9 l

SEA 1.66 l

UTE

-0.27 l

6 l

10 l

MEA 6.93 l

UTE

-0.21 6

l 12 l

SEA 3.00 l

UTE

-0.19 l

6 l

15 l

SEA 1.67 l

UTE

-0.25 l

6 l

18 l

MEA 1.65 l

UTE

-0.26 l

6 l

20 l

SEA 5.17 l

UTE

-0.15 l

6 l

25 l

MEA 1.80 l

UTE

-0.23 l

6 l

26 l

MEA 4.37 l

UTE

-0.20 l

6 l

27 l

SEA 2.46 l

UTE

-0.25 l

6 l

30 j

MEA 5.62 l

UTE

-0.18 l

6 l

38 l

MEA 1.64 l

UTE

-0.20 l

6 l

40 l

SEA 1.19 l

UTE

-0.20 l

7 l

2 l

SEA 1.33 l

UTE

-0.23 l

7 l

5 l

SEA 2.31 l

UTE

-0.08 l

l 7

l 10 l

SEA 2.83 l

UTE

-0.26 l

7 l

16 l

SEA 0.85 l

UTE

-0.24 l

7 l

17 l

SEA 8.53 l

UTE

-0.18 l

l 7

l 24 l

SEA 1.05 l

UTE

-0.22 l

7 l

28 l

MEA 2.00 l

UTE

-0.27 C______._____.__--___

Attachment to 1CAN069806 Page 76 of127 Table 8 (cont)

"B" OTSG Upper Roll Area Maws l

7 l

30 l

MEA l

1.98 l

UTE

-0.29 l

4 l

7 l

39 l

SEA l

0.86 l

UTE

-0.22 l

l 7

l 40 l

MEA l

0.93 l

UTE

-0.30 l

l 7

l 45 l

SEA l

0.99 l

UTE

-0.20 l

l 7

j 49 l

MEA l

2.61 l

UTE

-0.24 l

l 7

l 51 l

SEA l

0.75 l

UTE

-0.24 l

l 7

l 54 l

MEA l

0.99 l

UTE

-0.39 l

l 8

l 3

l SEA l

1.13 l

UTE

-0.27 l

l 8

l 4

l MEA l

5.71 l

UTE

-0.17 l

l 8

l 11 l

MEA l

1.74 l

UTE

-0.29 l

l 8

l 20 l

SEA l

4.53 l

UTE

-0.17 l

l 8

l 20 l

SAI l

0.62 l

UTE

-2.22 l

l 8

l 28 l

SEA l

2.30 l

UTE

-0.15 l

l 8

l 30 l

SEA l

6.83 l

UTE

-0.21 l

l 8

l 30 l

SAI l

0.88 l

UTE

-2.13 l

l 8

l 43 l

SEA l

1.09 l

UTE

-0.24 l

l 8

l 45 l

MEA l

1.09 l

UTE

-0.28 l

l 8

l 52 l

SEA l

0.94 l

UTE

-0.24 l

l 8

l 54 l

SVI l

0.88 l

UTE

-1.63 l

i l

8 l

57 l

SEA l

0.59 l

UTE

-0.21 l

l 9

l 7

l MEA l

7.15 l

UTE

-0.23 l

l 9

l 10 l

SEA l

1.34 l

UTE

-0.30 l

l 9

l 15 l

SEA l

4.33 l

UTE

-0.19 l

l 9

l 25 l

SAI l

0.22 l

UTE

-1.37 l

l 9

l 29 l

SEA l

4.39 l

UTE

-0.19 l

l 9

l 45 l

MEA l

1.77 l

UTE

-0.24 l

l 9

l 46 l

MEA l

0.74 l

UTE

-0.24 l

l 9

l 47 l

SEA l

1.77 l

UTE

-0.23 l

l 9

l 51 l

SAI l

0.56 l

UTE

-1.66 l

l 9

l 53 l

MEA l

1.45 l

UTE

-0.23 l

l 9

l 58 l

SEA l

0.85 l

UTE

-0.31 l

l 9

l 61 l

MEA l

1.78 l

UTE

-0.24 l

l 10 l

1 l

SEA l

0.95 l

UTE

-0.29 l

l 10 l

7 l

MEA l

2.53 l

UTE

-0.22 l

l 10 l

9 l

SEA l

1.04 l

UTE

-0.22 l

l 10 l

15 l

MEA l

2.55 l

UTE

-0.21 l

l 10 l

16 l

MEA l

1.22 l

UTE

-0.33 l

l 10 l

17 l

SEA l

1.09 l

UTE

-0.26 l

Attachment t@

lCAN069806 Page 77 cf127 l

l Table 8 (cost)

"B" OTSG Upper rom Area Flaws 10 l

35 l

SEA l

5.83 l

UTE

-0.16 l

10 l

45 l

SEA l

0.64 l

UTE

-0.30 l

10 l

55 l

SEA l

0.98 l

UTE

-0.26 l

10 l

64 l

SEA l

0.58 l

UTE

-0.29 l

11 l

8 l

MEA l

1.37 l

UTE

-0.22 l

11 l

9 l

MEA l

3.00 l

UTE

-0.31 l

11 l

10 l

MEA l

3.43 l

UTE

-0.27 l

11 l

55 l

MEA l

1.39 l

UTE

-0.20 l

11 l

57 l

MEA l

2.13 l

UTE

-0.27 l

11 l

58 l

MEA l

2.03 l

UTE

-0.22 l

11 l

59 l

MEA l

1.69 l

UTE

-0.22 l

11 l

60 l

SEA l

0.99 l

UTE

-0.21 l

12 l

11 l

MEA l

1.95 l

UTE

-0.22 l

12 l

12 l

SEA l

1.52 l

UTE

-0.25 l

12 l

18 l

SEA l

0.76 l

UTE

-0.30 l

12 l

19 l

MEA l

2.17 l

UTE

-0.19 l

12 l

20 l

MEA l

0.95 l

UTE

-0.33 l

12 l

25 l

MEA l

1.32 l

UTE

-0.18 l'

12 l

27 l

SEA l

1.87 l

UTE

-0.15 l

12 l

35 l

SEA l

0.82 l

UTE

-0.16 l

12 l

36 l

MEA l

1.31 l

UTE

-0.29 l

12 l

39 l

SEA l

1.51 l

UTE

-0.29 l

I 12 l

48 l

MEA l

2.12 l

UTE

-0.30 l

l 12 l

51 l

MEA l

1.04 l

UTE

-0.23 l

12 l

52 l

SEA l

1.73 l

UTE

-0.23 l

l 12 l

57 l

MEA l

1.06 l

UTE

-0.22 l

12 l

58 l

MEA l

1.83 l

UTE

-0.25 l

12 l

59 l

MEA l

2.58 l

UTE

-0.25 l

12 l

65 l

MEA l

0.95 l

UTE

-0.27 l

12 l

68 l

SEA l

1.58 l

UTE

-0.27 l

13 l

1 l

SEA l

1.24 l

UTE

-0.34 l

13 l

6 l

SEA l

1.10 l

UTE

-0.24 l

13 l

11 l

SEA l

1.91 l

UTE

-0.30 l

13 l

21 l

SEA l

0.70 l

UTE

-0.25 l

13 l

33 l

SEA l

0.45 l

UTE

-0.38 l

13 l

37 l

MEA l

2.33 l

UTE

-0.30 l

13 l

40 l

MEA l

1.45 l

UTE

-0.23 l

13 l

60 l

SEA l

0.78 l

UTE

-0.45 l

l l

Attachment to 1CAN069806 Page 78 of127 l

l Table 8 (cont) j "B" OTSG Upper Roll Area Flaws l

l 13 l

74 l

SAI l

0.89 l

UTE

-1.92 l

l l

l 14 l

12 l

MEA l

1.53 l

UTE

-0.24 l

1 l

14 l

13 l

MEA l

1.26 l

UTE

-0.31 l

)

l l

14 l

37 l

MEA l

2.10 l

UTE

-0.27 l

l 14 l

37 l

SAI l

0.82 l

UTE

-1.80 l

l l

14 l

38 l

MEA l

1.85 l

UTE

-0.32 l

l 14 l

45 l

MEA l

1.94 l

UTE

-0.26 l

l 14 l

50 l

MEA l

2.70 l

UTE

-0.24 l

l 14 l

51 l

MEA l

0.59 l

UTE

-0.24 l

l_ 14 l

53 l

SEA l

1.11 l

UTE

-0.29 l

1 l

14 l

60 l

MEA l

2.26 l

UTE

-0.31 l

l 14 l

63 l

SEA l

0.93 l

UTE

-0.26 l

l 14 l

67 l

SEA l

1.77 l

UTE

-0.27 l

l l

14 l

68 l

MEA l

2.17 l

UTE

-0.26 l

l 14 l

70 l

MEA l

2.98 l

UTE

-0.28 l

l l

14 l

72 l

MEA l

2.19 l

UTE

-0.23 l

l 15 l

13 l

SEA l

2.43 l

UTE

-0.33 l

l 15 l

14 l

MEA l

1.46 l

UTE

-0.23 l

l l

15 l

15 l

MEA l

1.70 l

UTE

-0.33 l

l 15 l

39 l

SAI l

0.54 l

UTE

-2.14 l

l 15 l

41 l

SEA l

2.65 l

UTE

-0.29 l

l 15 l

52 l

MEA l

1.80 l

UTE

-0.26 l

l 15 l

57 l

MEA l

4.46 l

UTE

-0.27 l

l 15 l

60 l

SEA

_ l 2.15 l

UTE

-0.25 l

l 16 l

5 l

EEA l

0.93 l

UTE

-0.31 l

l 16 l

15 l

SEA l

1.29 l

UTE

-0.31 l

l 16 l

16 l

MEA l

2.39 l

UTE

-0.25 l

l 16 l

33 l

MAI l

0.47 l

UTE

-2.14 l

l 16 l

48 l

SEA l

2.24 l

UTE

-0.25 l

l 16 l

66 l

SEA l

1.49 l

UTE

-0.06 l

l 16 l

73 l

MEA l

1.%

l UTE

-0.29 l

l 16 l

74 l

SEA l

2.04 l

UTE

-0.11 l

l 16 l

77 l

SEA l

2.23 l

UTE

-0.30 l

l 17 l

1 l

MEA l

3.40 l

UTE

-0.29 l

l 17 l

3 l

SEA l

0.88 l

UTE

-0.37 l

l 17 l

6 l

MEA l

1.42 l

UTE

-0.25 l

l 17 l

7 l

MEA l

1.55 l

UTE

-0.33 l

l 17 l

8 l

SEA l

1.72 l

UTE

-0.23 l

Attachment to 1CANM9806 Page 79 cf127 Tatde 8 (cost)

"B" OTSG Upper rom Area Flaws q

l 17 l

20 l

SEA l

1.41 l

UTE

-0.23 l

l 17 l

24 l

SEA l

2.42 l

UTE

-0.32 l

l 17 l

29 l

MEA l

1.59 l

UTE

-0.27 l

l 17 l

32 l

SEA l

1.%

l UTE

-0.29 l

l 17 l

33 l

SEA l

1.71 l

UTE

-0.27 l

l 17 l

54 l

SEA l

2.63 l

UTE

-0.10 l

l 17 l

60 l

SEA l

1.72 l

UTE

-0.11 l

l 17 l

66 l

SEA l

1.16 l

UTE

-0.06 l

l 17 l

72 l

SEA l

1.20 l

UTE

-0.09 l

l 17 l

73 l

MEA l

1.29 l

UTE

-0.30 l

l 18 l

1 l

SEA l

1.61 l

UTE

-0.28 l

l 18 l

1 l

SEA l

2.67 l

UTE

-0.29 l

l 18 l

3 l

MEA l

2.24 l

UTE

-0.26 l

l 18 l

4 l

MEA l

2.48 l

UTE

-0.34 l

l 18 l

7 l

SEA l

1.09 l

UTE

-0.29 l

l 18 l

8 l

SEA l

1.78 l

UTE

-0.35 l

l 18 l

25 l

MEA l

1.28 l

UTE

-0.27 l

l 18 l

26 l

SEA l

1.97 l

UTE

-0.29 l

l 18 l

53 l

SEA l

1.03 l

UTE

-0.25 l

l 18 l

65 l

MEA l

2.02 l

UTE

-0.27 l

l 18 l

67 l

MEA l

1.50 l

UTE

-0.27 l

l 18 l

73 l

SEA l

1.44 l

UTE

-0.29 l

l 18 l

74 l

MEA l

2.21 l

UTE

-0.09 l

l 18 l

74 l

SVI l

0.%

l UTE

-0.87 l

l 18 l

75 l

MEA l

3.02 l

UTE

-0.29 l

l 18 l

81 l

SEA l

1.61 l

UTE

-0.25 l

l l

19 l

1 l

MEA l

1.93 l

UTE

-0.33 l

l 19 l

1 j

SEA l

1.52 l.

UTE

-0.35 l

l 19 l

2 l

MEA l

2.11 l

UTE

-0.31 l

l 19 l

3 l

MEA l

1.13 l

UTE

-0.32 l

l 19 l

3 l

SEA l

1.81 l

UTE

-0.32 l

l 19 l

4 l

MEA l

2.42 l

UTE

-0.36 l

l 19 l

5 l

SEA l

0.92 l

UTE

-0.30 l

l 19 l

7 l

MEA.

l 1.64 l

UTE

-0.28 l

l 19 l

8 l

MEA l

1.90 l

UTE

-0.33 l

l 19 l

18 l

MEA l

1.63 l

UTE

-0.31 l

l 19 l

38 l

SEA l

1.05 l

UTE

-0.25' ~~l l

19 l

43 l

MEA l

1.44 l

UTE

-0.33 l

Attachment to ICAN069806 Page 80 of127 Table 8 (cont)

"B" OTSG Upper Roll Area Maws l

19 l

56 l

MEA l

1.28 l

UTE

-0.09 l

l 19 l

66 l

MEA l

1.27 l

UTE

-0.11 l

l 19 l

67 l

SEA l

1.87 l

UTE

-0.28 l

l 19 l

68 l

SEA l

1.21 l

UTE

-0.10 l

l 19 l

69 l

MEA l

0.97 l

UTE

-0.26 l

j l

19 l

72 l

SEA l

1.08 l

UTE

-0.10 l

l l

19 l

73 l

MEA l

1.18 l

UTE

-0.33 l

l 19 l

74 l

MEA l

2.65 l

UTE

-0.10 l

l 19 l

75 l

SEA l

1.35 l

UTE

-0.27 l

l 19 l

81 l

SEA l

1.54 l

UTE

-0.28 l

l 20 l

2 l

SEA l

3.21 l

UTE

-0.29 l

j l

20 l

4 l

SEA l

2.42 l

UTE

-0.28 l

l 20 l

5 l

MEA l

2.20 l

UTE

-0.33 l

l 20 l

6 l

S_EA l

2.80 l

UTE

-0.27 l

l 20 l

26 l

SEA l

2.02 l

UTE

-0.10 l

l 20 l

31 l

MEA l

1.75 l

UTE

-0.24 l

l l

20 l

37 l

SEA l

1.31 l

UTE

-0.27 l

l 20 l

48 l

SEA l

1.11 l

UTE

-0.36 l

[ 20 l

50 l

SEA l

1.91 l

UTE

-0.37 l

l 20 l

70 l

SEA l

1.12 l

UTE

-0.10 l

l 20 l

71 l

SEA l

1.33 l

UTE

-0.30 l

l 20 l

72 l

MEA l

1.58 l

UTE

-0.13 l

l 20 l

73 l

MEA l

2.20 l

UTE

-0.30 l

l 20 l

79 l

SAI l

2.56 l

UTE

-2.13 l

l 20 l

81 l

SEA l

0.61 l

UTE

-0.30 l

l 20 l

85 l

SEA l

2.12 l

UTE

-0.33 l

l 21 l

2 l

SEA l

1.12 l

UTE

-0.25 l

l 21 l

3 l

SEA l

2.41 l

UTE

-0.31 l

l 21 l

4 l

MEA l

2.70 l

UTE

-0.23 l

l 21 l

5 l

MEA l

1.60 l

UTE

-0.38 l

l l

21 l

6 l

SEA l

1.27 l

UTE

-0.27 l

l 21 l

9 l

SEA l

0.88 l

UTE

-0.25 l

l 21 l

19 l

SEA l

1.01 l

UTE

-0.41 l

l 21 l

27 l

MEA l

1.68 l

UTE

-0.40 l

l 21 l

35 l

SEA l

1.25 l

UTE

-0.34 l

l 21 l

42 l

SEA l

1.01 l

UTE

-0.34 l

l 21 l

65 l

SEA l

1.00 l

UTE

-0.25 l

l 21 l

77 l

SEA l

1.87 l

UTE

-0.11 l

Attachment ts I

1CAN069806 Page 81 of127 Table 8 (cont)

"B" OTSG Upper Roll Area Maws l

21 l

83 l

SEA l

0.91 l

UTE

-0.09 l

l 21 l

84 l

SEA l

1.17 l

UTE

-0.25 l

l 21 l

85 l

SEA l

1.38 l

UTE

-0.09 l

)

l 21 l

87 l

MEA l

2.88 l

UTE

-0.09 l

j l

21 l

89 l

SEA l

1.69 l

UTE

-0.10 l

l l

21 l

90 l

SEA l

1.34 l

UTE

-0.09 l

l l

22 l

4 l

MEA l

2.35 l

UTE

-0.39 l

l 22 l

6 l

MEA l

1.75 l

UTE

-0.33 l

l l

22 l

60 l

MEA l

1.90 l

UTE

-0.19 l

{

l 22 l

72 l

SEA l

1.53 l

UTE

-0.23 l

{

l 22 l

78 l

MEA l

0.72 l

UTE

-0.18 l

l l

23 l

5 l

SEA l

1.23 l

UTE

-0.27 l

l 23 l

6 l

MEA l

1.46 l

UTE

-0.18 l

)

l 23 l

13 l

SEA l

2.57 l

UTE

-0.28 l

l 23 l

16 l

SEA l

0.89 l

UTE

-0.43 l

l 23 l

33 l

SEA l

1.69 l

UTE

-0.19 l

l 23 l

69 l

MEA l

2.07 l

UTE

-0.16 l

l 24 l

2 l

SEA l

0.83 l

UTE

-0.17 l

l 24 l

3 l

SEA l

1.43 l

UTE

-0.19 l

l 24 l

4 l

MEA l

2.69 l

UTE

-0.21 l

l 24 l

5 l

SEA l

4.07 l

UTE

-0.22 l

l 24 l

6 l

MEA l

1.32 l

UTE

-0.21 l

l 24 l

7 l

MEA l

1.27 l

UTE

-0.21 l

l 24 l

8 l

MEA l

2.51 l

UTE

-0.18 l

l 24 l

13 l

MEA l

2.68 l

UTE

-0.22 l

l 24 l

29 l

MEA l

2.10 l

UTE

-0.23 l

l 24 l

38 l

MEA l

1.78 l

UTE

-0.20 l

l 24 l '43 l

SEA l

1.02 l

UTE

-0.21 l

l 24 l

49 l

SAI l

0.49 l

UTE

-1.04 l

l 24 l

72 l

MEA l

1.05 l

UTE

-0.23 l

l 24 l

80 l

SEA l

1.28 l

UTE

-0.20 l

l 24 l

86 l

MEA l

1.66 l

UTE

-0.29 l

l 24 l

89 l

SEA l

0.85 l

UTE

-0.09 l

l 24 l

92 l

MEA l

1.29 l

UTE

-0.23 l

l 24 l

93 l

SEA l

4.89 l

UTE

-0.33 l

l 25 l

1 l

MEA l

0.76 l

UTE

-0.21 l

l 25 l

3 l

MEA l

1.51 l

UTE

-0.16 ~,j l

25 l

4 l

MEA l

2.76 l

UTE

-0.29 l

l I

Attachment to 1CAN069806 Page 82 of127 Table 8 (cost)

"B" OTSG Upper Rou Area Flaws l

25 l

6 l

SEA l

0.83 l

UTE

-0.28 l

t l

25 l

7 l

MEA l

3.55 l

UTE

-0.29 l

l 25 l

9 l

MEA l

1.97 l

UTE

-0.22 _]

l 25 l

11 l

MEA l

2.69 l

UTE

-0.18 -

l l

25 l

13 l

SEA l

0.63 l

UTE

-0.21 l

l 25 l

15 l

SEA l

0.79 l

UTE

-0.22 l

l 25 l

19 l

MEA l

1.33 l

UTE

-0.22 l

l 25 l

21 l

SEA l

0.89 l

UTE

-0.23 l

'l 25 l

35 l

MEA l

2.16 l

UTE

-0.21 l

l 25 l

37 l

SEA l

1.04 l

UTE

-0.20 l

)

l 25 l

71 l

MEA l

1.13 l

UTE

-0.18 l

l l

25 l

72 l

SEA l

1.04 l

UTE

-0.08 l

I l

25 l-74 l

SEA l

0.65 l

UTE

-0.11 l

l '25 l

79 l

MEA l

1.21 l

UTE

-0.22 l

l 26 l

4 l

MEA l

1.31 l

UTE

-0.19 l

l l

26 l

5 l

SEA l

1.29 l

UTE

-0.20 l

l 26 l

6 l

MEA l

2.45 l

UTE

-0.20 l

l 26 l

7 l

SEA l

2.15 I

UTE

-0.20 l

l 26 l

8 l

MEA l

1.64 l

UTE

-0.18 l

l 26 l

9 l

SEA l

2.94 l

UTE

-0.18 l

l 26 l

10 l

MEA l

2.12 l

UTE

-0.22 l

l 26 l

11 l

MEA l

2.62 l

UTE

-0.20 l

l 26-l 15 l

MEA l

1.37 l

UTE

-0.21 l

l 26 l

16 l

SEA l

1.01 l

UTE

-0.20 l

l 26 l

33 l

SEA l

1.81 l

UTE

-0.22 l

l 26 l

37 l

SEA l

1.28 l

UTE

-0.22 l

l 26 l

72 l

MEA l

1.13 l

UTE

-0.23 l

l 26 l

74 l

MEA l

1.30 l

UTE

-0.20 l

l 26 l

82 l

SEA l

0.97 l

UTE

-0.22 l

)

l l

26 l

94 l

SEA' l

1.05 l

UTE

-0.27 l

L l

26' l 95 l

MAI l

0.24 l

UTE

-2.71 l

l l

27 l

5 l

MEA l

1.89 l

UTE

-0.28 l

'l 27 l

8 l

SEA l

0.33 l

UTE

-0.25 l

L l

27 l

9 l

MEA l

1.28 l

UTE

-0.34 l

l 27 l

10 l

MEA l

1.29-l UTE

-0.14 l

l 27 l

11 l

MEA l

1.85 l

UTE

-0.30 l

l 27 l

14 -l MEA l

0.82 l

UTE

-0.15 l

l 27 l

16 l

MEA l

3.33 l

UTE

-0.13 l

(

l.

Attachment to 1CAN069805 Page 83 of127 Table 8 (cont)

"B" OTSG Upper Roll Area Flaws UTE l

27 l

73 l

SEA l

1.30 UTE

-0.10 l

l 27 l

76 l

SEA l

2.01 UTE

-0.29 l

l 27 l

84 l

SEA l

2.00 UTE

-0.20 l

l 27 l

93 l

SEA l

0.75 UTE

-0.25 l

l 27 l

99 l

SAI l

0.48 UTE

-2.51 l

l 28 l

7 1 SEA l

1.35 UTE

-0.33 l

l 2S l

8 MEA l

1.74 UTE

-0.17 l

l 28 l

11 SEA l

1.44 UTE

-0.23 l

l 28 l

12 MEA l

0.89 UTE

-0.17 l

l 28 l

50 MEA l

0.57 UTE

-0.20 l

l 28 l

83 SEA l

1.46 UTE

-0.10 l

l 28 l

91 SEA l

0.62 UTE

-0.12 l

l 28 l

SEA l

1.55 UTE

-0.21 l

l 28 l 101 SEA l

1.23 UTE

-0.17 l

l 29 l

8 MEA l

1.36 UTE

-0.29 l

l 29 l

11 MEA l

1.83 UTE

-0.29 l

l 29 l

12 MEA l

1.12 UTE

-0.35 l

l 29 l

13 SEA l

2.40 UTE

-0.31 l

l 29 l

16 SEA l

1.83 UTE

-0.33 l

l 29 l

18 SEA l

1.08 UTE

-0.34 l

l 29 l

93 SEA l

1.17 UTE

-0.17 l

l 29 l

99 SEA l

2.33 UTE

-0.16 l

l 29 l 103 SEA l

1.38 UTE

-0.10 l

l 30 l

7 MEA l

2.60 UTE "0.24 l

[_ 30 l

8 MEA l

1.29 UTE

-0.34 l

l 30 l

11 SEA l

1.34 UTE

-0.43 l

l 30 l

12 MEA l

1.81 UTE

-0.23 l

l 30 l

14 MEA l

2.04 UTE

-0.23 l

l 30 l

17 SEA l

0.75 UTE

-0.29 l

l 30 l

72 SEA l

0.80 UTE

-0.18 l

l 30 l

94 SEA l

1.75 UTE

-0.24 l

l 30 l

95 SEA l

1.60 UTE

-0.17 l

l 30 l

97 SEA l

1.24 UTE 0.16 l

l 30 l 101 MEA l

1.62 UTE

-0.15 l

l 30 l 102 MEA l

1.79 UTE

-0.28 l

l 31 l

8 hEA l

31.09 UTE

-0.31 l

l 31 l

11 SEA l

0.82 UTE

-0.30 l

l 31 l

14 SEA l

17.11 UTE

-0.29 l

Attachment to 1CAN069806 Page 84 of127 Table 8 (cont)

"B" OTSG Upper Roll Area Maws

-0.28 l

31 l

26 l

SEA l

0.66 l

UTE

-0.16 l

31 l

76 l

MEA l

1.24 l

UTE

-0.18

~

l 31 l

79 l

SEA l

0.84 l

UTE

-0.28 l

31 l

96 l

AEA l

1.42 l

UTE

-0.36 l

31 l

97 l

SEA l

1.65 l

UTE

-0.21 l

31 l

99 l

MEA l

1.80 l

UTE

-0.23 l

31 l 100 l MEA l

3.31 l

UTE

-0.26 l

31 l 102 l MEA l

2.44 l

UTE

-0.18 l

31 l

103 l SEA l

1.75 l

UTE

-0.18 l

31 l 104 l SEA l

2.14 l

UTE

-0.24 l

31 l

106 l SEA l

2.06 l

UTE

-0.31 l

32 l

1 l

MEA l

1.03 l

UTE

-0.22 l

32 l

8 l

SEA l

2.06 l

UTE

-0.27 l

32 l

13 l

MEA l

1.04 l

UTE

-0.26 l

32 l

19 l

SEA l

15.78 l

UTE

-0.23 l

32 l

33 l

SVI l

0.23 l

UTE

-1.51 l

32 l

37 l

MEA l

2.02 l

UTE

-0.27 l

32 l

39 l

SEA l

1.88 l

UTE

-0.25 l

32 l

40 l

SEA l

1.75 l

UTE

-0.19 l

32 l

41 l

MEA l

2.09 l

UTE

-0.29 l

32 l

94 l

SEA l

1.56 l

UTE

-0.23 l

32 l

102 l SEA l

1.13 l

UTE

-0.21 l

32 l

104 l SEA l

0.83 l

UTE

-0.29 l

32 l

105 l SEA l

1.41 l

UTE

-0.29 l

33 l

9 l

MEA l

26.97 l

UTE

-0.31 l

33 l

14 l

SEA l

0.94 l

UTE

-0.22 l

33 l

20 l

MEA l

1.62 l

UTE

-0.25 l

33 l

45 l

SA1 l

0.32 l

UTE

-1.67 l

33 l

60 l

SEA l

1.30 l

UTE

-0.19 l

33 l

77 l

MEA l

1.00 l

UTE

-0.20 l

33 l

78 l

SEA l

1.43 l

UTE

-0.22 l

33 l 103 l SEA l

0.82 l

UTE

-0.20 l

34 l

8 l

SEA l

1.10 l

UTE

-0.22 l

34 l

9 l

MEA l

1.46 l

UTE

-0.24 l

34 l

11 l

MEA l

1.94 l

UTE

-0.21 l

34 l

14 l

AEA l

1.19 l

UTE

-0.20 l

34 l

15 l

hEA l

1.05 l

UTE

-0.29 l

34 l

16 l

SEA l

16.52 l

UTE

-0.27

1CAN069806 Page 85 cf127 Table 8 (cont)

"B" OTSG Upper Rou Area Flaws l

34 l

71 l

SVI l

0.53 l

UTE

-2.12 l

l 34 l

76 l

SEA l

1.55 l

UTE

-0.26 l

l 34 l

85 l

SEA l

1.15 l

UTE

-0.18 l

l 34 l

91 l

MEA l

1.66 l

UTE

-0.29 l

l 34 l 107 l SEA l

1.25 l

UTE

-0.19 l

l 35 l

4 l

SEA l

1.64 l

UTE

-0.17 l

l 35 l

11 l

MEA l

1.29 l

UTE

-0.17 l

l 35 l

12 l

MEA l

2.48 l

UTE

-0.20 l

'l 35 l

13 l

SEA l

1.84 l

UTE

-0.16 l

l 3$

l 15 l

MEA l

1.20 l

UTE

-0.27 l

l 35 l

18 l

MEA l

1.65 l

UTE

-0.22 l

l 35 l

20 l

MEA l

0.65 l

UTE

-0.20 l

l 35 l

21 l

SEA l

1.91 l

UTE

-0.31 l

l 35 l

24 l

SEA l

1.45 l

UTE

-0.23 l

l 35 l

37 l

MEA l

1.20 l

UTE

-0.17 l

l 35 l

38 l

SEA l

1.37 l

UTE

-0.26 l

l 35 l

40 l

SEA l

0.62 l

UTE

-0.22 l

l 35 l

49 l

SEA l

8.69 l

UTE

-0.28 l

[ 35 l

52 l

SEA l

0.97 l

UTE

-0.26 l

l 35 l

57 l

SEA l

1.72 l

UTE

-0.28 l

l 35 l

76 l

SEA l

1.06 l

UTE

-0.16 l

l 35 l

79 l

SEA l

2.01 l

UTE

-0.25 l

l 35 l

89 l

SEA l

0.73 l

UTE

-0.16 l

l 35 l 100 l SEA l

0.98 l

UTE

-0.34 l

l 35 l 101 l MEA l

1.56 l

UTE

-0.24 l

l 35 l 102 l SEA l

0.73 l

UTE

-0.32 l

l 35 l-104 l SEA l

1.27 l

UTE

-0.32 l

l 35 l 105 l SEA l

0.80 l

UTE

-0.25 l

l 36 l

1 l

MEA l

2.02 l

UTE

-0.21 l

l 36 l

2 l

MEA l

1.01 l

UTE

-0.22 l

l 36 l

3 l

SEA l

2.09 l

UTE

-0.21 l

)

l 36 l

10 l

MEA l

0.64 l

UTE

-0.15 l

l l

36 l

14 l

MEA l

1.86 l

UTE

-0.17 l

l 36 l

16 l

SEA l

1.68 l

UTE

-0.16 l

l 36 l

17 l

SEA l

1.26 l

UTE

-0.30 l

l 36 l

18 l

SEA l

1.34 l

UTE

-0.12 l

l 36 l

29 l

SEA l

0.62 l

UTE

-0.18 l

l 36 l 107 l MEA l

0.92 l

UTE

-0.28 l

Attachment to 1CAN%9806 Page 86 cf 127 Table 8 (cont)

"B" OTSG Upper Roll Area Flaws l

37 l

11 l

SEA l

0.%

l UTE

-0.21 l

37 l

12 l

MEA l

1.00 l

UTE

-0.19 l

37 l

13 l

SEA l

1.61 l

UTE

-0.23 l

37 l

13 l

SAI l

1.08 l

UTE

-2.07 l

37 l

14 l

MEA l

2.39 l

UTE

-0.18 l

37 l

15 l

MEA l

3.11 l

UTE

-0.25 l

37 l

17 l

MEA l

2.17 l

UTE

-0.23 l

37 l

23 l

MEA l

1.51 l

UTE

-0.28 l

37 l

24 l

MEA l

0.56 l

UTE

-0.25 l

37 l

30 l

SEA l

0.66 l

UTE

-0.32 l

37 l

97 l

MEA l

1.04 l

UTE

-0.30 l

38 l

2 l

SEA l

2.09 l

UTE

-0.22 l

38 l

12 l

MEA l

2.57 l

UTE

-0.22 l

38 l

13 l

MEA l

1.86 l

UTE

-0.15 l

38 l

15 l

MEA l

1.51 l

UTE

-0.15 l

38 l

30 l

MEA l

1.22 l

UTE

-0.35 I

l 38 l

81 l

MEA l

1.25 l

UTE

-0.27 l

38 l 100 l SEA l

0.76 l

UTE

-0.24 l

38 l 109 l MEA l

1.31 l

UTE

-0.27 l

38 l 110 l MEA l

1.34 l

UTE

-0.21 l

38 l 111 l SEA l

2.24 l

UTE

-0.29 l

38 l 112 l MEA l

1.04 l

UTE

-0.22 l

38 l 112 l SAI l

0.14 l

UTE

-2.26 l

38 l 113 l SEA l

1.48 l

UTE

-0.15 l

38 l 115 l SEA l

2.04 l

UTE

-0.25 l

39 l

1 l

MEA l

0.54 l

UTE

-0.16 l

39 l

5 l

SEA l

1.12 l

UTE

-0.20 l

39 l

11 l

MEA l

1.42 l

UTE

-0.18 L 39 l

13 l

MEA l

1.46 l

UTE

-0.14 l

39 l

20 l

SEA l

0.61 l

UTE

-0.54 I

39 l

23 l

SEA l

1.61 l

UTE

-0.15 l

39 l

32 l

SEA l

0.59 l

UTE

-0.20 l

39 l

41 l

SEA l

1.71 l

UTE

-0.23 l

39 l

42 l

SEA l

0.80 l

UTE

-0.16 l

39 l

74 l

SAI l

0.37 l

UTE

-1.61 l

39 l

88 l

MEA l

1.36 l

UTE

-0.25 l

39 l 108 l SEA l

1.47 l

UTE

-0.19 l

39 l 112 l SEA l

0.98 l

UTE

-0.46

Attachment to 1CAN069806 Page 87 of127 Table 8 (cont) i "B" OTSG Upper Roll Area Haws Ir L

39 0 115 ll SEA ll 1.11

[

UTE

-0.25 L

l 40 l

8 l

MEA 1.08 l

UTE

-0.16 l

l l

40 l

13 l

MEA 0.95 l

UTE

-0.23 l

l 40 l

16 l

MEA 0.75 l

UTE

-0.16 l

1 l

40 l

24 l

SEA 1.31 l

UTE

-0.15 l

l 40 l

31 l

SEA 1.86 l

UTE

-0.24 l

l 40 l

42 l

SEA 0.86 l

UTE

-0.22 l

l 40 l

54 l

MEA 0.78 l

UTE

-0.12 l

l 40 l

59 l

MEA 1.%

l UTE

-0.31 l

l 40 l 104 l SEA 1.56 l

UTE

-0.25 l

l 40 l 107 l MEA 1.13 l

UTE

-0.19 l

l 40 l 108 l MEA 1.23 l

UTE

-0.13 l

l 40 l 111 l SEA 0.57 l

UTE

-0.18 l

l 40 l

112 l MEA 0.94 l

UTE

-0.14 l

l 40 l 114 l SEA 0.80 l

UTE

-0.10 l

l 41 l

1 l

MEA 3.03 l

UTE

-0.23 l

l 41 l

4 l

MEA 1.69 l

UTE

-0.23 l

l 41 l

8 l

MEA 1.64 l

UTE

-0.24 l

l 41 l

11 l

SEA 1.18 l

UTE

-0.15 l

l 41 l

13 l

SEA 2.94 l

UTE

-0.20 l

l 41 l

14 l

SEA 1.51 l

UTE

-0.23 l

l 41 l

15 l

MEA 1.91 l

UTE

-0.17 l

l 41 l

16 l

MEA 0.92 l

UTE

-0.28 l

l 41 l

20 l

MEA 2.24 l

UTE

-0.25 l

l 41 l

82 l

SEA 0.85 l

UTE

-0.27 l

l 41 l 107 l SEA 0.72 l

UTE

-0.19 l

l 42 l

5 l

SEA 1.66 l

UTE

-0.28 l

l 42 l

9 l

SEA 1.90 l

UTE

-0.28 l

l 42 l

17 l

MEA 2.38 l

UTE

-0.22 l

l 42 l

24 l

MEA 1.70 l

UTE

-0.17 l

l 42 l

60 l

SEA 1.41 l

UTE

-0.16 l

l 42 l

97 l

MEA 1.56 l

UTE

-0.28 l

l 42 l

99 l

SEA 1.85 l

UTE

-0.24 l

l 42 l 109 l SEA 1.29 l

UTE

-0.34 l

l 43 l

51 l

SAI 0.53 l

UTE

-1.13 l

l 43 l 115 l SEA 0.72 l

UTE

-0.25 l

l 44 l

32 l

SEA 0.94 l

UTE

-0.37 l

l 44 l 115 l SEA 1.85 l

UTE

-0.48 l

l 45 l

1 l

SEA 2.03 l

UTE

-0.16 l

l Attachment to 1CAN069806 Page 88 ef127 I

Table 8 (cost)

"B" OTSG Upper ReE Area Flaws l

45 l

52 l

SAI l

0.21 l

UTE

-1.77 l

l 45 l

78 l

SVI l

0.23 l

UTE

-1.58 l

l 46 l

16 l

SEA l

0.64 l

UTE

-0.23 l

l 46 l

19 l

MEA l

1.00 l

UTE

-0.21 l

l 47 l

2 l

MEA l

2.37 l

UTE

-0.30 l

l 47 l 118 l SEA l

0.83 l

UTE

-0.17 l

l 48 l

1 l

SEA l

0.63 l

UTE

-0.25 l

l 48 l

16 l

MEA l

1.23 l

UTE

-0.33 l

l 48 l

17 l

MEA l

1.55 l

UTE

-0.30 l

l 48 l

20 l

MEA l

1.22 l

UTE

-0.18 l

l 48 l

20 l

MEA l

1.06 l

UTE

-0.26 l

l 48 l

62 l

SEA l

1.94 l

UTE

-0.20 l

l 48 l 107 l SEA l

0.51 l

UTE

-0.22 l

l 48 l

123 l SEA l

2.06 l

UTE

-0.26 l

l 49 l

19 l

SEA l

0.75 l

UTE

-0.21 l

l 50 l

2 l

MEA l

3.09 l

UTE

-0.26 l

l 50 l

8 l

SEA l

8.65 l

UTE

-0.38 l

l 50 l

70 l

SVI l

0.29 l

UTE

-1.80 l

l 50 l 120 l SEA l

1.34 l

UTE

-0.15 l

l 51 l

1 l

MEA l-0.69 l

UTE

-0.25 l

l 51 l

3 l

MEA l

1.60 l

UTE

-0.21 l

l 51 l

8 l

SEA l

1.38 l

UTE

-0.20 l

l 51 l

62 l

SVI l

0.40 l

UTE

-1.70 l

l 51 l

62 l

SVI l

0.30 l

UTE

-2.38 l

-l 51 1

62 l

SVI l

0.61 l

UTE

-2.92 l

l 51 l

82 l

SVI l

0.38 l

UTE

-2.21 l

l 51 l

82 l

SVI l

0.44 l

UTE

-2.44 l

l 51 l

90 l

SVI l

0.47 l

UTE

-1.70 l

l 51 l 106 l SEA l

1.08 l

UTE

-0.18 l

l 51 l 112 l SEA l

0.72 l

UTE

-0.15 l

l 51 l 118 l SEA l

0.63 l

UTE

-0.19 l

l 52 l

1 l

MEA l

2.51 l

UTE

-0.29 l

l 52 l

2 l

SEA l

4.43 l

UTE

-0.25 l

l 52 l

3 l

MEA l

1.78 l

UTE

-0.29 l

l 52 l

9 l

SEA l

4.77 l

UTE

-0.29 l

l 52 l

12 l

MEA l

2.36 l

UTE

-0.21 l

l 52 l

21 l

SEA l

2.84 l

UTE

-0.33 l

l 52

] 122 l SEA l

0.90 l

UTE

-0.21 l

Attachment to 1CAN069806 Page 89 of127 Table 8 (cost)

"B" OTSG Upper Roll Area Maws l

53 l

1 l

MEA l

1.45 l

UTE

-0.20 l

l 53 l

2 l

MEA l

1.88 l

UTE

-0.28 l

1 l

53 l

3 l

MEA l

2.24 l

UTE

-0.23 l

l 53 l

8 l

SEA l

3.48 l

UTE

-0.22 l

l 53 l

9 l

SEA l

1.28 l

UTE

-0.24 l

l 53 l

45 l

MAI l

0.75 l

UTE

-2.41 l

l 53 l

46 l

MAI l

0.21 l

UTE

-2.39 l

l 53 l

63 l

SVI l

0.72 l

UTE

-2.58 l

l 53 l

85 l

SEA l

1.97 l

UTE

-0.38 l

l 53 l 126 l SEA l

1.35 l

UTE

-0.27 l

l 54 l

1 l

MEA l

1.48 l

UTE

-0.24 l

l 54 l

2 l

SEA l

2.65 l

UTE

-0.67 l

l 54 l

18 l

MEA l

0.88 l

UTE

-0.08 l

l 54 l

34 l

SEA l

0.47 l

UTE

-0.40 l

l 54 l

47 l

SAI l

0.61 l

UTE

-2.11 l

l 54 l

59 l

SAI l

0.60 l

UTE 1.20 l

l 55 l

1 l

MEA l

2.39 l

UTE

-0.28 l

l 55 l

3 l

SEA l

7.08 l

UTE

-0.24 l

l 55 l

4 l

SEA l

1.53 l

UTE

-0.20 l

l 55 l

34 l

MEA l

0.60 l

UTE

-0.41 l

l 55 l

46 l

MAI l

0.20 l

UTE

-2.44 l

l 55 l

49 l

SAI l

0.25 l

UTE

-1.97 l

)

l 56 l

1 l

MEA l

0.84 l

UTE

-0.31 l

l 56 l

3 l

MEA l

2.46 l

UTE

-0.14 l

l 56 l

4 l

SEA l

1.73 l

UTE

-0.20 l

l 56 l

7 l

SEA l

0.64 l

UTE

-0.18 l

l 56 l

46 l

SAI l

0.45 l

UTE

-2.33 l

l 57 l

1 l

MEA l

2.08 l

UTE

-0.25 l

l 57 l

2 l

MEA l

0.%

l UTE

-0.18 l

l l

57 l

4 l

MEA l

1.25 l

UTE

-0.20 l

l l

57 l-29 l

SEA l

1.33 l

UTE

-0.19 l

l 57 l

55 l

SEA l

1.56 l

UTE

-0.44 l

l 57 l 126 l SEA l

0.95 l

UTE

-0.20 l

l 57 l 128 l SEA l

1.62 l

UTE

-0.24 l

l 58 l

1 l

MEA l

1.26 l

UTE

-0.23 l

l 58 l

2 l

MEA l

1.56 l

UTE

-0.23 l

l 58 l

3 l

MEA l

2.29 l

UTE

-0.24 l

l 58 l

4 l

MEA l

2.25 l

UTE

-0.21 l

l

Attachment to 1CANM9806 Page 90 of127 Table 8 (cont)

"B" OTSG Upper Roll Area Maws MEA 0.24 c

I l

58 l

11 MEA 1.46 l

UTE

-0.13 l

58 l

25 MEA 0.92 l

UTE

-0.19 l

58 l

35 MEA 0.69 l

UTE

-0.22 l

58 l

84 SVI 1.94 l

UTE

-1.00 l

58 l 124 SAI 0.45 l

UTE

-1.99 l

59 l

1 SEA 2.57 l

UTE

-0.21 l

59 l

2 MEA 2.10 l

UTE

-0.28 l

59 l

3 MEA 2.82 l

UTE

-0.21 l

59 l

5 MEA 1.51 l

UTE

-0.21 l

59 l

10 SEA 1.76 l

UTE

-0.23 l

59 l

34 SEA 0.94 l

UTE

-0.26 l

59 l 120 SEA 1.06 l

UTE

-0.28 l

59 l

120 SAI 0.82 l

UTE

-2.10 l

59 l

123 MEA 1.63 l

UTE

-0.26 l

60 l

1 MEA 1.19 l

UTE

-0.35 l

60 l

4 SEA 1.91 l

UTE

-0.20 l

60 l

11 SEA 1.56 l

UTE

-0.19 l

60 l

21 SEA 0.94 l

UTE

-0.20 l

60 l

47 SAI 0.46 l

UTE

-2.03 l

60 l 124 MA.T 0.22 l

UTE

-1.83 l

61 l

4 MEA 2.44 l

UTE

-0.22 l

61 l

5 MEA 1.53 l

UTE

-0.20 l

61 l

7 SEA 1.75 l

UTE

-0.21 l

61 l

23 SEA 1.64 l

UTE

-0.28 l

62 l

4 SEA 2.17 l

UTE

-0.18 l

62 l

5 SEA 2.88 l

UTE

-0.20 l

62 l

5 SEA 1.63 l

UTE

-0.34 l

62 l

22 SEA 1.40 l

UTE

-0.24 l

62 l

107 SEA 0.93 l

UTE

-0.11 l

63 l

5 MEA 2.47 l

UTE

-0.23 l___63 l

6 MEA 1.54 l

UTE

-0.36 l

63 l

49 SEA 0.75 l

UTE

-0.26 l

63 l

49 SAI 0.35 l

UTE

-2.03 l

63 l

50 SAI 0.60 l

UTE

-1.86 l

63 l 129 SEA 0.95 l

UTE

-0.27 l

64 l

21 SEA 1.73 l

UTE

-0.23 l

64 l

49 SAI 0.96 l

UTE

-1.96 l

64 l

60 SEA 1.12 l

UTE

-0.15

Attachment to 1CAN069806 Page 91 of127 Table 8 (cont)

"B" OTSG Upper Roll Area Flaws 65 14 S

65 20 SEA l

1.89 l

UTE

-0.18 65 37 SEA l

0.56 l

UTE

-0.25 65 48 MAI l

0.07 l

UTE

-1.28 65 49 SAI l

0.32 l

UTE

-2.43 66 6

SEA l

1.19 l

UTE

-0.26 66 12 SEA l

1.71 l

UTE

-0.23 66 20 hEA l

1.82 l

UTE

-0.21 66 21 SEA l

1.15 l

UTE

-0.20 66 26 SEA l

1.68 l

UTE

-0.23 67 11 SEA l

1.52 l

UTE

-0.25 67 48 SEA l

0.70

-l UTE

-0.19 67 103 MEA l

2.20 l

UTE

-0.28 68 20 MEA l

1.09 l

UTE

-0.28 69 21 SEA l

1.32 l~

UTE

-0.24 69 22 SEA l

1.58 l

UTE

-0.26 69 25 SEA l

1.26 l

UTE

-0.15 69 48 SAI l

0.41 l

UTE

-2.15 69 50 SAI l

0.71 l.

UTE

-0.15 UTE

-2.10 69 65 SEA l

0.86 l

70 24 MEA l

1.50 l

UTE

-0.25 70 74 SVI l

0.12 l

UTE

-1.97 71 26 MEA l

1.62 l

UTE

-0.29 71 51 SAI l

0.64 l

UTE

- 1.7.2 72 128 SEA l

1.41 l

UTE

-0.12 73 26 SEA l

_l.71 l

UTE

-0.27 73 48 MAI l

0.08 l

UTE

-1.81 73 51 SAI l

0.96 l

UTE

-1.75 74 35 SAI l

0.31 l

UTE

-1.49 74 50 SAI l

0.73 l

UTd

-1.92 74 124 SAI l

0.66 l

UTE

-1.08 75 103 SEA l

1.22 l

UTE

-0.05 77 65 SAI l

0.77 l

UTE

-1.13 77 95 SVI l

0.36 l

UTE

-2.04 77 121 SAI l

0.55 l

UTE

-1.81 79 19 SEA l

1.79 l

UTE

-0.24 79 54 SEA l

1.31 l

UTE

-0.23 79 95 SEA l

0.82 l

UTE

-0.18 80 66 SEA l

2.27 l

UTE

-0.37

Attachment to 1CAN069806 Page 92 of127 Table 8 (cost)

"B" OTSG Upper rom Area Maws l

81 l

14 l

SEA l

2.15 l

UTE

-0.26 l

l 81 l

70 l

MAI l

0.20 l

UTE

-0.94 l

l 82 l

11 l

SEA l

2.72 l

UTE

-0.24 l

l 83 l

14 l

SEA l

1.01 l

UTE

-0.28 l

l 83 l

74 l

MAI l

0.14 l

UTE

-1.40 l

l 84 l

8 l

SEA l

2.87 l

UTE

-0.22 l

l 84 l

9 l

SEA l

1.65 l

UTE

-0.23 l

l 84 l

10 l

MEA l

2.33 l

UTE

-0.31 l

l l

84 l

15 l

SEA l

1.31 l

UTE

-0.29 l

l 84 l

26 l

SEA l

1.44 l

UTE

-0.36 l

l 84 l_ 30 l

SEA l

1.12 l

UTE

-0.49 l

l 84 98 l

MAI l

0.21 l

UTE

-1.47 l

l 85 7

l MEA l

2.03 l

UTE

-0.30 l

l 85 9

l SEA l

3.02 l

UTE

-0.32 l

l 85 14 l

MEA l

2.29 l

UTE

-0.32 l

l 85 18 l

SEA l

1.68 l-UTE

-0.37 l

l 85 55 l

SEA l

5.02 l

UTE

-0.36 l

L l

85 62 l

SEA l

3.10 l

UTE

-0.10 l

l' l

85 63 l

MEA l

1.47 l

UTE

-0.30 l

l l

85 97 l

SAI l

0.55 l

UTE

-1.55 l

l 86 8

l SEA l

1.00 l

UTE

-0.26 l

l 86 9

l MEA l

2.56 l

UTE

-0.22 l

l 86 10 l

MEA l

2.79 l

UTE

-0.20 l

l 86 14 l

MEA l

2.64 l

UTE

-0.35 l

l 86 20 l

SEA l

1.72 l

UTE

-0.32 l

l 86 -

26 l

SEA l

0.69 l

UTE

-0.37 l

l 86 80 l

SEA l

1.79 l

UTE

-0.41 l

l 86 97 l

SAI l

0.56 l

UTE

-1.71 l

l 87 5

l SEA l

1.89 l

UTE

-0.27 l

l 87 6

l SEA l

1.87 l

UTE

-0.26 l

l 87 7

l SEA l

1.66-l UTE

-0.28 l

l 87 10 l

SEA l

0.65 l

UTE

-0.23 l

l 87 13 l

SEA l

1.76 l

UTE

-0.17 l

l 87 17 l

SEA l

2.38 l

UTE

-0.42 l

l 87 37 l

MAI l

0.22 l

UTE

-0.92 l

l 87 71 l

SEA l

1.42 l

UTE

-0.23 l

l' 88 6

l SEA l

1.18 l

UTE

-0.29 l

l 88 7

l SEA l

1.69 l

UTE

-0.30 l

l

Attachment to 1CAN069806 Page 93 of127 Table 8 (coat)

"B" OTSG Upper Rou Area Flaws l

88 l

9 l

SEA l

2.98 l

UTE

-0.29 l

l 88 l

10 l

SEA l

2.25 l

UTE

-0.26 l

l 88 l

11 l

MEA l

2.57 l

UTE

-0.32 l

l 88 l

13 l

MEA l

1.97 l

UTE

-0.27 l

l 88 l

14 l

SEA l

1.66 l

UTE

-0.27 l

l 88 l

15 l

SEA l

1.75 l

UTE

-0.31 l

l 88 l

17 l

MEA l

1.78 l

UTE

-0.32 l

l 88 l

22 l

SEA l

1.80 l

UTE

-0.30 l

l l

88 l

51 l

MAI l

0.16 l

UTE

-1.72 l

l 88 l

80 l

SEA l

0.72 l

UTE

-0.33 l

l 88 l

97 l

MAI l

0.21 l

UTE

-1.58 l

l 89 l

8 l

SEA l

1.09 l

UTE

-0.23 l

l 89 l

9 l

MEA l

2.40 l

UTE

-0.31 l

l 89 l

10 l

MEA l

2.59 l

UTE

-0.27 l

i l

89 l

13 l

MEA l

1.64 l

UTE

-0.29 l

l 89 l

55 l

SEA l

0.54 l

UTE

-0.14 l

l l

89 l

55 l

MEA l

2.00 l

UTE

-0.26 l

l 89 l

55 l

MEA l

1.21 l

UTE

-0.32 l

l 89 l

57 l

SAI l

0.33 l

UTE

-1.35 l

l 89 l

70 l

SEA l

5.09 l

UTE

-0.11 l

l 89 l

76 l

SEA l

2.60 l

UTE

-0.25 l

l 89 l

97 l

SAI l

0.67 l

UTE

-1.73 l

l 89 l

98 l

SAI l

1.59 l

UTE

-2.18 l

l 90 l

4 l

MEA l

1.56 l

UTE

-0.34 l

l 90 l

5 l

SEA l

1.18 l

UTE

-0.23 l

l 90 l

6 l

SEA l

2.03 l

UTE

-0.34 l

l 90 l

10 l

SEA l

1.62 l

UTE

-0.21 l

l 90 l

21 l

MEA l

1.22 l

UTE

-0.29 l

l 90 l

49 l

MAI l

0.21 l

UTE

-1.20 l

l 90 l

54 l

SEA l

1.37 l

UTE

-0.16 l

l l

90 l

97 l

SAI l

0.16 l

UTE

-1.65 l

l l

90 l 110 l MAI l

0.29 l

UTE

-1.69 l

l l

90 l 126 l SAI l

3.51 l

UTE

-2.10 l

l 91 l

7 l

SEA l

1.14 l

UTE

-0.22 l

l 91 l

8 l

SEA l

2.03 l

UTE

-0.31 l

l 91 l

9 l

SEA l

2.17 l

UTE

-0.26 l

l 91 l

10 l

SEA l

1.85 l

UTE

-0.30 l

l 91 l

13 l

SEA l

1.66 l

UTE

-0.23 l

Attachment to 1CAN069806 Page 94 of127 Table 8 (cont)

"B" OTSG Upper Roll Area Maws UTE l

91 l

51 l

MAI l

0.16 l

UTE

-1.69 l

l 91 l

98 l

MEA l

1.47 l

UTE

-0.22 l

l 91 l 107 l SAI l

0.44 l

UTE

-2.76 l

l 92 l

3 l

SEA l

2.17 l

UTE

-0.29 l

l 92 l

7 l

MEA l

1.07 l

UTE

-0.28 l

l 92 l

9 l

SEA l

1.97 l

UTE

-0.24 l

l 92 l

10 l

SEA l

1.69 l

UTE

-0.26 l

l 92 l

11 l

SEA l

1.50 l

UTE

-0.32 l

l 92 l

14 l

SEA l

0.76 l

UTE

-0.33 l

l 92 l

18 l

SEA l

0.90 l

UTE

-0.36 l

l 92 l

80 l

SVI l

0.49 l

UTE

-1.47 l

l 92 l

114 l SEA l

1.11 l

UTE

-0.36 l

l 92 l

116 l SEA l

1.89 l

UTE

-0.41 l

l 92 l

126 l MAI l

0.26 l

UTE

-2.24 l

l 92 l 127 l SEA l

1.20 l

UTE

-0.29 l

l 92 l

129 l MEA l

1.40 l

UTE

-0.25 l

l 93 l

2 l

SEA l

1.99 l

UTE

-0.16 l

l 93 l

4 l

SEA l

1.42 l

UTE

-0.23 l

l 93 l

7 l

SEA l

2.17 l

UTE

-0.16 l

l 93 l

8 l

MEA l

2.25 l

UTE

-0.26 l

l 93 l

9 l

SEA l

1.67 l

UTE

-0.12 l

l 93 l

12 l

SEA l

2.16 l

UTE

-0.29 l

l 93 l

19 l

SAI l

3.79 l

UTE

-2.68 l

l 93 l

52 l

SAI l

0.61 l

UTE

-1.54 l

l 93 l 111 l SEA l

1.36 l

UTE

-0.27 l

l 93 l 112 l MEA l

2.67 l

UTE

-0.31 l

l 93 l 113 l SEA l

2.66 l

UTE

-0.40 l

l 94 l

5 l

SEA l

0.60 l

UTE

-0.22 l

l 94 l

7 l

SEA l

1.82 l

UTE

-0.26 l

l 94 l

8 l

SEA l

2.62 l

UTE

-0.17 l

l 94 l

9 l

SEA l

1.54 l

UTE

-0.37 l

y f

l 94 l

10 l

MEA l

2.01 l

UTE

-0.20 l

l 94 l

13 l

SEA l

2.02 l

UTE

-0.15 l

l 94 l

14 l

SEA l

1.80 l

UTE

-0.19 l

l 94 l

20 l

SEA l

1.25 l

UTE

-0.17 l

l 94 l

70 l

SEA l

1.14 l

UTE

-0.35 l

l 94 l

80 l

SEA l

1.26 l

UTE

-0.30 l

l 94 l

80 l

SVI l

1.85 l

UTE

-1.65 l

Y

4 Attachment to ICAN069806 Pag 3 95 of127 Table 8 (cont)

"B" OTSG Upper Roll Area Maws l

94 l

102 l MEA l

1.05 l

UTE

-0.26 l

l 94 l 129 l SEA l

1.78 l

UTE

-0.24 l

l 95 l

6 l

SEA l

1.25 l

UTE

-0.19 l

l 95 l

7 l

MEA l

3.42 l

UTE

-0.23 l

l 95 l

8 l

SEA l

1.78 l

UTE

-0.27 l

)

l 95 l

9 l

MEA l

3.31 l

UTE

-0.26 l

l 95 l

12 l

SEA l

2.28 l

UTE

-0.34 l

l 95 l

13 l

SEA l

2.68 l

UTE

-0.26 l

l l

95 l

16 l

SEA l

1.41 l

UTE

-0.22 l

l 95 l

20 l

SEA l

1.42 l

UTE

-0.22 l

l 95 l

128 l SEA l

2.26 l

UTE

-0.23 l

l l

1 l

SEA l

0.82 l

UTE

-0.17 l

l l

3 l

MEA l

1.37 l

UTE

-0.26 l

l l

5 l

SEA l

2.32 l

UTE

-0.20 l

l l

7 l

SEA l

3.50 l

UTE

-0.24 l

l l

8 l

SEA l

2.20 l

UTE

-0.21 l

l 96 l

10 l

SEA l

1.02 l

UTE

-0.22 l

l l

12 l

SEA l

2.38 l

UTE

-0.28 l

l l

48 l

SAI l

0.46 l

UTE

-2.25 l

l l

78 l

MEA l

0.93 l

UTE

-0.25 l

l 96 l

78 l

MEA l

2.46 l

UTE

-0.33 l

l l

78 l

SVI l

0.40 l

UTE

-1.52 l

l 97 l

5 l

MEA l

1.06 l

UTE

-0.20 l

l 97 l

6 l

MEA l

2.31 l

UTE

-0.19 l

l 97 l

7 l

MEA l

2.21 l

UTE

-0.20 l

l 97 l

8 l

SEA l

2.71 l

UTE

-0.22 l

l 97 l

16 l

MEA l

1.95 l

UTE

-0.22 l

l 97 l

17 l

SEA l

0.46 l

UTE

-0.20 l

l 97 l

18 l

SEA l

1.50 1

UTE

-0.23 l

l 97 l

27 l

MAI l

0.24 l

UTE

-2.16 l

l 98 l

3 l

MEA l

1.74 l

UTE

-0.21 l

l 98 l

8 l

MEA l

1.24 l

UTE

-0.32 l

l 98 l

48 l

SEA l

0.82 l

UTE

-0.33 l

l 98 l

63 l

SAI l

0.75 l

UTE

-1.48 l

l 98 l 105 l SEA l

0.83 l

UTE

-0.24 l

l 99 l

1 l

MEA l

0.93 l

UTE

-0.20 l

l 99 l

1 l_

SAI l

0.47 l

UTE

-1.39 l

l 99 l

2 l _ MEA l

0.83 l

UTE

-0.23 l

L_--_-------------

Attachment to 1CANM9806 Page % of127 Table 8 (cont)

"B" OTSG Upper Roll Area Flaws l

99 l

28 l

SAI l

0.56 l

UTE

-1.48 l 100 l 2

l SAI l

0.23 l

UTE

-1.61 I

l 100 l 6

l SEA l

1.98 l

UTE

-0.33 l 100 l 37 l

SAI l

0.47 l

UTE

-1.77 l 100 l 78 l

SEA l

0.70 l

UTE

-0.28 t

l 100 l 103 l SEA l

1.35 l

UTE

-0.22 l 100 l 115 l SAI l

0.36 l

UTE

-1.69 l 101 l 5

l SEA l

2.70 l

UTE

-0.32 l 101 l 6

l MEA l

1.23 l

UTE

-0.28 l 101 l 17 l

SEA l

1.23 l

UTE

-0.34 l 101 l 71 l

SVI l

4.24 l

UTE

-2.73 l 102 l 5

l MEA l

1.95 l

UTE

-0.22 l

l 102 l 6

l SEA-l 2.19 l

UTE

-0.30 l 102 l 7

l SEA l

0.88 l

UTE

-0.07 l 102 l 64 l

SVI l

5.03 l

UTE

-2.41 l 103 l 5

l MEA l

1.95 l

UTE

-0.29 l 103 l 6

l SEA l

2.11 l

UTE

-0.26 l 103 l 7

l SEA l

2.12 l

UTE

-0.32 l 103 l 10 l

MEA l

2.58 l

UTE

-0.17 l 103 l 11 l

SEA l

1.73 l

UTE

-0.30 l 104 l 2

l SEA l

1.47 l

UTE

-0.30 l 104 l 4

l SEA l

0.61 l

UTE

-0.28 l 104 l 5

l SEA l

1.59 l

UTE

-0.28 l 104 l 6

l SEA l

1.57 l

UTE

-0.26 l 104 l 10 l

MEA l

1.31 l

UTE

-0.16 l 104 l 16 l

SEA l

1.25 l

UTE

-0.28 l 104 l 17 l

SEA l

1.59 l

UTE

-0.17 l 104 l 108 l SAI l

0.88 l

UTE

-1.82 l 105 l 4

l SEA l

3.67 l

UTE

-0.29 l 105 l 5

l MEA l

2.78 l

UTE

-0.18 l 105 l 6

l SEA l

2.21 l

UTE

-0.35 l 105 l 9

l SEA l

1.87 l

UTE

-0.17 l 105 l.10 l

SEA l

2.26 l

UTE

-0.30 l 105 l 14 l

SEA l

2.03 l

UTE

-0.31 l 105 l 15 l

SEA l

1.18 l

UTE

-0.30 l 105 l 56 l

SAI l

0.68 l

UTE

-1.74 l 105 l 62 l

SEA l

1.56 l

UTE

-0.20 l 106 l 2

l SEA l

1.43 l

UTE

-0.18

Attachment to 1CAN069806 Pags 97 cf127 Table 8 (cont)

"B" OTSG Upper Roll Area Flaws l 106 l 5

l SEA l

0.88 l

UTE

-0.19 l

l 106 l 6

l SEA l

1.27 l

UTE

-0.33 l

l 106 l 7

l MEA l

1.57 l

UTE

-0.19 l

l 106 l 10 l

MEA l

1.24 l

UTE

-0.20

_l l 106 l 12 l

SEA l

1.48 l

UTE

-0.26 l

l 106 l 14 l

SEA l

1.43 l

UTE

-0.26 l

l 106 l 26 l

SEA l

0.56 l

UTE

-0.32 l

l 106 l 119 l SEA l

2.73 l

UTE

-0.43 l

l 107 l 1

l MEA l

3.33 l

UTE

-0.21 l

l 107 l 2

l MEA l

1.57 l

UTE

-0.18 l

l 107 l 3

l MEA l

3.97 l

UTE

-0.22 l

l 107 l 4

l MEA l

2.54 l

UTE

-0.18 l

l 107 l 5

l SEA l

2.56 l

UTE

-0.29 l

l 107 l 8

l MEA l

2.40 l

UTE

-0.19 l

l 107 l 9

l MEA l

1.40 l

UTE

-0.32 l

l 107 l 26 l

SEA l

1.27 l

UTE

-0.26 l

l 107 l 89 l

SEA l

1.27 1

UTE

-0.31 l

l 107 l 99 l

SEA l

1.63 l

UTE

-0.25 l

l 107 l 100 l SEA l

2.15 l

UTE

-0.29 l

l 108 l 1

l SEA l

2.10 l

UTE

-0.28 l

l l 108 l 3

l SEA l

2.40 l

UTE

-0.29 l

l 108 l 4

l SEA l

2.67 l

UTE

-0.16 l

l 108 l 5

l MEA l

3.19 l

UTE

-0.31 l

l 108 l 7

l SEA l

1.37 l

UTE

-0.30 l

4 l 108 l 8

l SEA l

1.51 l

UTE

-0.18 l

l 108 l 36 l

SAI l

0.30 l

UTE

-1.92 l

l 108 l 76 l

SAI l

0.37 l

UTE

-1.95 l

i l 108 l 106 l SAI l

0.65 l

UTE

-1.90 l

l 108 l 119 l SEA l

0.91 l

UTE

-0.11 l

l 109 l 1

l SEA l

1.49 l

UTE

-0.21 l

l 109 l 2

l MEA l

1.91 l

UTE

-0.19 l

l 109 l 3

l SEA l

2.28 l

UTE

-0.11 l

l 109 l 4

l MEA l

1.47 l

UTE

-0.23 l

.l 109 l 7

l MEA l

2.17 l

UTE

-0.13 l

l 109 l 19 l

SEA l

0.90 l

UTE

-0.13 l

l 109 l 22 l

SEA l

1.16 l

UTE

-0.28 l

l 109 l 70 l

SAI l

0.30 l

UTE

-2.61 l

l 109 l 99 l

SEA l

1.05 l

UTE

-0.29 l

l

Attachment to 1CAN069806 Page 98 of127 Table 8 (cost)

"B" OTSG Upper Roll Area Flaws l 109 l 118 l MEA l

1.85 l

UTE

-0.33 l

l 110 l 3

l SEA l

1.94 l

UTE

-0.13 l

l 110 l 4

l MEA l

1.89 l

UTE

-0.15 l

l 110 l 5

l SEA l

1.28 l

UTE

-0.12 l

l 110 l 7

l SEA l

1.27 l

UTE

-0.11 l

l 110 l 8

l SEA l

1.84 l

UTE

-0.13 l

l 110 l 10 l

SEA l

1.71 l

UTE

-0.02 l

l 110 l 13 l

MEA l

1.88 l

UTE

-0.22 l

l 110 l 14 l

SEA l

1.48 l

UTE

-0.11 l

l 110 l 18 l

SEA l

1.12 l

UTE

-0.20 l

l 110 l 74 l

SAI l

0.75 l

UTE

-2.17 l

l 110 l 87 l

MAI l

0.13 l

UTE

-1.90 l

l 111 l 1

l SEA l

2.82 l

UTE

-0.12 l

l 111 l 2

l SEA l

2.07 l

UTE

-0.12 l

l 111 l

6 l

MEA l

1.51 l

UTE

-0.13 l

l 111 l

7 l

MEA l

1.24 l

UTE

-0.10 l

l 111 l 9

l SEA l

1.10 l

UTE

-0.17 l

l 111 l 13 l

SEA l

1.17 l

UTE

-0.16 l

l 111 l 14 l

MEA l

1.71 l

UTE

-0.16 l

l 111 l 18 l

MEA l

1.57 l

UTE

-0.18 l

l 111 l 65 l

SAI l

0.56 l

UTE

-1.57 l

l 112 l 4

l MEA l

1.76 l

UTE

-0.10 l

l 112 l 7

l SEA l

1.26 l

UTE

-0.15 l

l 112 l 8

l MEA l

2.67 l

UTE

-0.14 l

l 112 l 9

l MEA l

2.17 l

UTE

-0.09 l

l 112 l 14 l

MEA l

1.46 l

UTE

-0.17 l

l 112 l 15 l

SEA l

1.57 l

UTE

-0.10 l

l 112 l 18 l

MEA l

2.06 l

UTE

-0.11 l

l 112 l 20 l

SEA l

1.45 l

UTE

-0.08 l

l 112 l 35 l

SAI l

0.23 l

UTE

-1.76 l

l 112 l 65 l

MAI l

0.91 l

UTE

-2.42 l

l 112 l 68 l

SAI l

0.94 l

UTE

-2.49 l

l 112 l 70 l

SAI l

0.63 l

UTE

-2.41 l

l 113 l 3

l MEA l

1.53 l

UTE

-0.13 l

l 113 l 6

-l SEA l

1.75 l

UTE

-0.17 l

l 113 l 7

l MEA l

1.38 l

UTE

-0.13 l

l 113 l 9

l SEA l

2.48 l

UTE

-0.18 l

l 113 l 14 l

SEA l

1.92 l

UTE

-0.15 l

Attachment to ICAN069806 Page 99 of127 Table 8 (cont)

"B" OTSG Upper Roll Area Maws

-0.14 l 113 l 19 l

SEA l

1.42 l

UTE

-0.06 l 113 l 20 l

MEA l

2.67 l

UTE

-0.18 l 113 l 98 l

SEA l

1.21 l

UTE

-0.23 l 114 l 2

l SEA l

1.89 l

UTE

-0.11 l

l 114 l 6

l SEA l

1.78 l

UTE

-0.13 l 114 l 7

l MEA l

2.38 l

UTE

-0.13 i

l 114 l 8

l SEA l

1.70 l

UTE

-0.12 l 114 l 9

l MEA l

2.04 l

UTE

-0.15 l 114 l 97 l

SEA l

0.64 l

UTE

-0.13 l

l 115 l 3

l SEA l

1.08 l

UTE

-0.15 i

l 115 l 4

l SEA l

1.87 l

UTE

-0.16 l

l 115 l 6

l SEA l

1.83 l

UTE

-0.11 l 115 l 8

l SEA l

1.19 l

UTE

-0.12 l

l 115 l 9

l SEA l

1.32 l

UTE

-0.16 I 115 l 13 l

SEA l

1.22 l

UTE

-0.17 l 115 l 25 l

SAI l

0.50 l

UTE

-1.67 l 115 l 53 l

SAI l

0.70 l

UTE

-2.44 l 116 l 1

l MEA l

2.32 l

UTE

-0.31 l

l 116 l 2

l SEA l

2.54 l

UTE

-0.13 1

l 116 l 4

l SEA l

1.37 l

UTE

-0.12 l

l 116 l 6

l MEA l

1.91 l

UTE

-0.17 l

l 116 l 7

l MEA l

1.29 l

UTE

-0.13 l

l 116 l 12 l

SEA l

1.45 l

UTE

-0.12

)

l 116 l 13 l

MEA l

2.41 l

UTE

-0.11 l

l 116 l 33 l

MAI l

0.21 l

UTE

-1.53 l

116 l 113 l SEA l

2.26 l

UTE

-0.34 l 117 l 3

l MEA l

0.78 l

UTE

-0.17 l 117 l 4

l MEA l

1.17 l

UTE

-0.08 l 117 l 5

l SEA l

1.12 l

UTE

-0.16 l

l 117 l 6

l MEA l

1.89 l

UTE

-0.12 l 117 l 15 l

SEA' l

1.22 l

UTE

-0.18 l 117 l 22 l

SEA l

0.79 l

UTE

-0.24 l

l 117 l 50 l

SEA l

0.80 l

UTE

-0.23 l 117 l 61 l

SAI l

0.42 l

UTE

-1.58 l 117 l 82 l

SEA l

0.28 l

UTE

-0.35 l 118 l 1

l SEA l

0.76 l

UTE

-0.26 l 118 l 2

l SEA l

1.76 l

UTE

-0.11 l 118 l 3

l SEA l

1.48 l

UTE

-0.24 l

l L --- -

1

Attachment to 1CAN0698%

Page 100 Cf127 Table 8 (coat)

"B" OTSG Upper Rou Area Maws 118 118 10 l

MEA l

2.29 l

UTE

-0.19 l

119 1

l SEA l

1.82 l

UTE

-0.22 l

119 11 l

SEA l

0.93 l

UTE

-0.20 l

119 21 l

SEA l

0.93 l

UTE

-0.23 l

119 22 l

SEA l

0.59 l

UTE

-0.19 l

119 108 l SEA l

0.90 l

UTE

-0.50 l

120 59 l

SEA l

3.60 l

UTE

-0.20 l

120 107 l SEA l

1.11 l

UTE

-0.38 l

120 107 l SAI l

0.54 l

UTE

-1.13 l

121 2

l MEA l

1.09 l

UTE

-0.12 l

121 8

l SEA l

0.95 l

UTE

-0.14 l

121 106 l SEA l

1.26 l

UTE

-0.20 l

122 6

l SEA l

1.07 l

UTE

-0.14 l

122 20 l

MEA l

2.26 l

UTE

-0.24 l

123 1

l MEA l

3.48 l

UTE

-0.22 l

123 2

l SEA l

0.71 l

UTE

-0.22 l

123 5

l MEA l

2.21 l

UTE

-0.18 l

123 6

l SEA l

1.72 l

UTE

-0.17 l

123 7

l SEA l

1.41 l

UTE

-0.19 l

123 9

l SEA l

2.13 l

UTE

-0.16 l

123 13 l

SEA 0.50 l

UTE

-0.14 l

124 5

l SEA 0.64 l

UTE

-0.29 l

124 36 l

SAI 0.82 l

UTE

-1.67 l

124 93 l

SEA 0.76 l

UTE

-0.36 l

125-1 l

SEA 1.40 l

UTE

-0.11 l

l 125 4

l SEA 2.09 l

UTE

-0.22 l

l 125 5

l SEA 1.65 l

UTE

-0.13 l

125 11 l

SEA 0.68 l

UTE

-0.23 l

125 56 l

MEA 2.29 l

UTE 4).31 l

125 81 l

SEA 0.94 l

UTE

-0.23 l

125 85 l

SEA 0.94 l

UTE

-0.23 l

125 86 l

MEA 2.18 l

UTE

-0.21 l

125 93 l

SEA 1.74 l

UTE

-0.27 l

126 10 l

MEA 1.27 l

UTE

-0.44 l

126 11 l

SEA 2.02 l

UTE

-0.14 l

126 26 l

SAI 0.42 l

UTE

-2.21 l

126 55 l

SEA 1.30 l

UTE

-0.29 l

126 79 l

SEA 0.94 l

UTE

-0.22 l

Attack-t to 1CAN069806 Page 101 of127 Table 8 (coat)

"B" OTSG Upper rom Area Flaws l 126 l 91 l

SEA l

0.73 l

UTE

-0.22 l

l 126 l l

SEA l

1.77 l

UTE

-0.18 l

l 127 l 1

l MEA l

2.81 l

UTE

-0.21 l

l 127 l 2

l MEA l

1.75 l

UTE

-0.27 l

l 127 l 4

l SEA l

1.14 l

UTE

-0.11 l

l 127 l 15 l

SEA l

1.16 l

UTE

-0.24 l

l 127 l 21 l

SEA l

1.25 l

UTE

-0.25 l

l 127 l 49 l

SEA l

2.99 l

UTE

-0.31 l

l 127 l 64 l

SEA l

3.69 l

UTE

-0.21 l

l 127 l 65 l

SEA l

4.60 l

UTE

-0.27 l

l 127 l 78 l

SEA l

1.49 l

UTE

-0.26 l

l 127 l 80 l

SEA l

0.64 l

UTE

-0.23 l

l 127 l 86 l

SEA l

0.70 l

UTE

-0.28 l

l 128 l 3

l SEA l

1.50 l

UTE

-0.26 l

l 128 l 21 l

SEA l

1.01 l

UTE

-0.23 l

l 128 l 60 l

SEA l

0.78 l

UTE

-0.21 l

l 128 l 79 l

SAI l

0.30 l

UTE

-1.50 l

l 128 l 91 l

MEA l

0.77 l

UTE

-0.27 l

l 128 l 92 l

SAI l

0.63 l

UTE

-1.35 l

l 129 l 2

l SEA l

1.92 l

UTE

-0.22 l

l 129 l 15 l

SEA l

1.76 l

UTE

-0.32 l

l 129 l 79 l

SEA l

0.83 l

UTE

-0.24 l

l 129 l 79 l

SAI l

0.35 l

UTE

-1.48 l

l 129 l 91 l

MAI l

0.18 l

UTE

-1.37 l

l 129 l 94 l

MEA l

1.65 l

UTE

-0.30 l

l 130 l 2

l SEA l

3.25 l

UTE

-0.24 l

l 130 l 51 l

MEA l

0.81 l

UTE

-0.25 l

l 130 l 52 l

SEA l

2.74 l

UTE

-0.33 l

l 130 l 57 l

SEA l

0.72 l

UTE

-0.17 l

l 130 l 63 l

SEA l

1.39 l

UTE

-0.29 l

l 130 l 75 l

SEA l

0.98 l

UTE

-0.29 l

l 130 l 87 l

MEA l

1.63 l

UTE

-0.27 l

l 130 l 92 l

SEA l

1.07 l

UTE

-0.19 l

l 131 l 1

l MEA l

2.70 l

UTE

-0.23 l

l 131 l 69 l

SEA l

1.11 l

UTE

-0.21 l

l 131 l 72 l

SEA l

1.41 l

UTE

-0.23 l

l 131 l 85 l

SEA l

1.11 l

UTE

-0.19 l

l 131 l 86 l

SEA l

0.89 l

UTE

-0.24 l

l l

l

Attachment to ICAN069806 Page 102 of127 Table 8 (cost)

"B" OTSG Upper Roll Area Flaws l 132 l 17 l

MEA l

1.90 l

UTE

-0.54 l

l 132 l 18 l

SEA l

1.45 l

UTE

-0.30 l

l 132 l 20 l

SEA l

1.19 l

UTE

-0.57 l

l 132 l 21 l

SEA l

0.76 l

UTE

-0.41 l

l 132 l 47 l

SEA l

1.94 l

UTE

-0.25 l

l 132 l 48 l

SEA l

1.13 l

UTE

-0.24 l

l 132 l 52 l

SEA l

0.80 l

UTE

-0.24 l

l 132 1 53 l

SEA l

1.43 l

UTE

-0.30 l

l 132 l 77 l

SEA l

1.31 l

UTE

-0.28 l

l 132 l 79 l

SEA l

1.99 l

UTE

-0.24 l

l 132 l 80 l

SEA l

1.15 l

UTE

-0.22 l

l 132 l 81 l

SEA l

0.53 l

UTE

-0.22 l

l 132 l 85 l

SEA l

0.60 l

UTE

-0.23 l

l 133-l 5

l SEA l

0.68 l

UTE

-0.35 l

l 133 l 10 l

SEA l

0.79 l

UTE

-0.27 l

l 133 l 11 l

SEA l

1.14 l

UTE

-0.31 l

l 133 l 13 l

SEA l

1.55 l

UTE

-0.23 l

l 133 l 15 l

SEA l

1.60 l

UTE

-0.25 l

l 133 l 48 l

MEA l

1.10 l

UTE

-0.24 l

l 133 l 59 l

SEA l

0.83 l

UTE

-0.20 l

l 133 l 78 l

SEA l

1.07 l

UTE

-0.30 l

l 134 l 49 l

SAI l

0.83 l

UTE

-1.66 l

l 134 l 59-l MEA l

1.16 l

UTE

-0.24 l

l 134 l 77 l

SEA l

2.20 l

UTE

-0.25 l

l 134 l 81 l

MEA l

1.19 l

UTE

-0.30 l

l l 134 l 85 l

MEA l

0.98 l

UTE

-0.25 l

l 135 l 1

l SEA l

0.78 l

UTE

-0.26 l

l 135 l 24 l

SAI l

1.09 l

UTE

-1.45 l

l 135 l 46 l

MEA l

1.20 l

UTE

-0.12 l

l 135 l 57 l

MEA l

1.35 l

UTE

-0.15 l

l 135.l 68 l

MEA l

1.09 l

UTE

-0.31 l

L l 135 l 69 l

SEA l

1.89 l

UTE

-0.23 l

l 135 l 72 l

MEA l

0.97 l

UTE

-0.25 l

l 135 l 80 l

SEA l

0.73 l

UTE

-0.25 l

l 135 l 81 l

MEA l

0.76 l

UTE

-0.26 l

l 135 l 82 l

SEA l

1.32 l

UTE

-0.29 l

l 136 l 11 l

SEA

.l 1.90 l

UTE

-0.30 l

l 136 l 45 l

SEA I

2.27 l

UTE

-0.36 l

Attachment to ICAN%9806 Page 103 cf127 Table 8 (coat)

"B" OTSG Upper Roh Area Haws SEA l 136 l 47 l

SEA 1.80 l

UTE

-0.38 l

l l 136 l 51 l

SEA 0.92 l

UTE

-0.29 l

l l 136 l 61 l

SEA 0.87 l

UTE

-0.20 l

l l 136 l 69 l

SEA 0.56 l

UTE

-0.26 l

l 136 l 75 l

MEA 1.11 l

UTE

-0.24 l

l 136 l 76 l

SEA 1.04 l

UTE

-0.14 l

l 136 l 79 l

MEA 1.12 l

UTE

-0.23 l

l 137 l 7

l MEA 0.93 l

UTE

-0.72 l

l 137 l 9

l SEA 1.85 l

UTE

-0.53 l

l 137 l 10 l

SEA 1.31 l

UTE

-0 23 l

l 137 l 15 l

SEA 1.01 l

UTE

-0.15 l

l 137 l 44 l

SEA 0.81 l

UTE

-0.63 l

l l 137 l 45 l

MEA 4.10 l

UTE

-0.19 l

l 137 l 59 l

MEA 1.74 l

UTE

-0.27 l

l 137 l 72 l

SEA 1.04 l

UTE

-0.30 l

l 137 l 78 l

SEA 1.66 l

UTE

-0.26 l 138 l 5

l SEA 1.23 l

UTE

-0.30 l 138 l 8

l SEA 0.91 l

UTE

-0.44 l 138 l 10 l

MEA 2.14 l

UTE

-0.40 l 138 l 20 l

SEA 1.83 l

UTE

-0.13 l 138 l 21 l

SAI 1.19 l

UTE

-2.57 l 138 l 42 l

SEA 1.12 l

UTE

-0.13 l 138 l 54 l

MEA 0.93 l

UTE

-0.24 l '

l 138 l 55 l

SEA 3.16 l

UTE

-0.35 l 138 l 64 l

SEA 1.51 l

UTE

-0.24 l 138 l 65 l

SEA 0.71 l

UTE

-0.28 l 138 l 67 I

SEA 0.73 l

UTE

-0.29 l 139 l 1

l SVI 0.45 l

UTS

+21.68 l 139 l 12 l

SEA 1.88 l

UTE

-0.23 l 139 l 19 l

SEA 0.61 l

UTE

-0.23 l 139 l 36 l

SEA 0.95 l

UTE

-0.22 l

l 139 l 47 l

SEA 0.57 l

UTE

-0.24 l 139 l 47 l

SAI 0.46 l

UTE

-1.48 l 139 l 60 l

SEA 2.40 l

UTE

-0.26 l 139 l 67 l

SEA 1.30 l

UTE

-0.26 l 139 l 73 l

SEA 0.86 l

UTE

-0.24 l 140 l 1

l SAI 0.52 l

UTE

-1.69 l 140 l 17 l

SEA 1.80 l

UTE

-0.22

Attachment to 1CAN069806 Page 104 cf127 Table 8 (cost)

"B" OTSG Upper Rou Area Flaws l 140 l 35 l

SEA l

1.26 l

UTE

-0.16 l

l 140 l 41 l

SEA l

2.83 l

UTE

-0.20 l

l 140 l 46 l

MEA l

0.85 l

UTE

-0.22 l

l l 140 l 52 l

SEA l

1.15 l

UTE

-0.26 l

l 140 l 62 l

SEA l

2.28 l

UTE

-0.22 l

l l 140 l 63 l

SEA l

1.32 l

UTE

-0.29 l

l 140 l 64 l

MEA l

1.32 l

UTE

-0.23 l

l 140 l-70 l

SEA l

1.44 l

UTE

-0.24 l

l l 140 l 71 l

MEA l

1.20 l

UTE

-0.29 l

l 141 l 33 l

MAI l

0.20 l

UTE

-1.95 -

l l 141 l 48 l

SEA l

1.73 l

UTE

-0.22 l

l 141 l 55 l

SEA l

1.06 l

UTE

-0.25 l

l 141 l-61 l

SEA I

1.05 I

UTE

-0.27 l

l 141 l 62 l

MEA l

1.63 l

UTE

-0.21 l

l 141 l 63 l

SEA l

1.03 l

UTE

-0.29 l

l 142 l 15 l

SAI l

0.%

l UTE

-2.10 l

l 142 l 38 l

SEA l

1.72 l

UTE

-0.36 l

l 142 l 42 l

MEA l

1.63 l

UTE

-0.29 l

l 142 l 51 l

SEA l

2.49 l

UTE

-0.22 l

l 142 l 60 l

MEA l

0.83 l

UTE

-0.24 l

l l 143 l 15 l

SAI l

1.08 l

UTE

-2.23 l

l 143 l 41 l.

SEA l

2.89 l

UTE

-0.21 l

l 143 l 62 l

SEA l

1.33 l

UTE

-0.29 l

l 144 l 12-l SAI l

0.75 l

UTE

-3.01 l

)

l 144 l 57 l

SEA l

0.86 l

UTE

-0.23 l

l 145 l 11 l

MAI l

0.20 l

UTE

-2.21 l

l 145 l 21 l

SEA l

1.07 l

UTE

-0.51 l

l 145 l 34 l

MEA l

1.16 l

UTE

-0.33 l

l 145 l 38 l

SEA l

0.92 l

UTE

-0.23 l

l 145 1 40 l

SEA l

0.78 l

UTE

-0.21 l

l 145 l 44 l

MEA l

1.97 l

UTE

-0.25 l

l 145 l 47 l

SEA l

0.81 l

UTE

-0.23 l

l 145 - l 54 l

SEA l

0.95 l

UTE

-0.28 l

l 146 l 5

l SEA l

1.14 l

UTE

-0.21 l

l 146 l 8

l SEA l

0.61 l

UTE

-0.49 l

l 146 l 14 l

MEA l

1.29 l

UTE

-0.58 l

l 147 l 2

l SEA l

0.84 l

UTE

-0.34 l

l 147 l 16 l

SEA l

1.07 l

UTE

-0.30 l

(

l Attachment to ICAN069806 Page 105 of127 i

l Table 8 (cont)

"B" OTSG Upper Roll Area Maws l 147 l 39 l

SEA l

1.65 l

UTE

-0.47 l

l l 148 l 29 l

SEA l

3.39 l

UTE

-0.3 4 -

l l

l 148 l 36 l

SEA l

1.62 l

UTE

-0.32 l

i l 148 l 37 l

SEA l

3.55 l

UTE

-0.43 l

l l 148 l 41 l

MEA l

1.02 l

UTE 0.22 l

l 149 l 27 l

SEA l

1.36 l

UTE

-0.22 l

l 149 l 28 l

SEA l

1.42 l

UTE

-0.31 l

l l 149 l 29 l

SEA l

0.82 l

UTE

-0.20 l

l l 149 l 30 l

SEA l

1.61 l

UTE

-0.21 l

l 149 l 31 l

SEA l

1.83 l

UTE

-0.19 l

l l 149 l 33 l

SEA l

0 90 l

UTE

-0.20 l

l 149 l 33 l

SVI l

1.vJ l

UTE

-1.02 l

l 150 l 24 l

SEA l

0.59 l

UTE

-0.20 l

l 150 l 27 l

SEA l

2.17 l

UTE

-0.29 l

l l 151 l 13 l

SEA l

0.77 l

UTE

-0.58 l

l l

l i

Attachment to ICAN069806 Page 106 ef127 Table 9 "A" OTSG Tube Support Plate Mechanical Wear f

2 3

l 5

l 18 l

10S

+0.39 3

l 5

l 14 l

115

-0.25 3

l 5

l 11 l

lIS

-0.80 3

l 7

l 14 l

10S

+0.26 4

l 1

l 11 l

10S

+0.62 4

l 34 l

13 l

09S

-0.30 5

l 1

l 12 l

10S

+0.39

)

5 l

37 l

15 l

09S

-0.08 6

l 41 l

14 l 08S

+0.55 6

l 41 l

18 l

08S

-0.53 10 l

7 l

27 l

085

-0.46 10 l

12 l

12 l 07S

+0.83 12 l

2 l

14 l 09S

+0.24 l

12 l

10 l

17 l

07S

-0.13 12 l

61 l

14 l

07S

-0.27 12 l

69 l

21 l

10S

+0.54 l

14 l

75 l

20 l

10S

+0.63 16 l

80 l

25 l

10S

%.53 18 l

84 l

16 l

10S

%.50 19 l

78 l

16 l 08S

+0.53 19 l

80 l

23 l 08S

+0.67 19 l

83 l

7 l

08S

-0.61 l

19 l

83 l

13 l

09S

-0.27 20 l

75 l

29 l

08S

-0.32 20 l

84 l

15 l

lIS

-0.72 21 l

86 l

14 l

07S

-0.24 22 l

82 l

17 l

08S

-0.27 22 l

87 l

13 l

08S

-0.05 22 l

87 l

10 l

08S

-0.62 23 l

4 l

12 l 03S

+0.70 23 l

94 l

11 l

10S

+0.62 l

24 l

48 l

8 l

07S

-0.24 26 l

47 l

12 l OSS

+0.48 29 l

8 l

19 l 07S

+0.73 32 l

4 l

34 l 09S

+0.65 32 l

5 l

31 l 09S

+0.71 32 l

6 l

18 l 09S

+0.62 37 l

6 l

33 l 09S M.69 1

Attachment to 1CAN069806 Page 107 of127 Table 9 (cont)

"A" OTSG Tube Support Plate Mechanical Wear 3

1 l

38 l

112 l

28 l

09S

-0.24 l

l 40 l

114 l

15 l 08S

+0.57 l

42 l

115 l

21 l 08S

+0.50 l

l 43 l

45 l

9 l 06S

+0.75 l

l 44 l

58 l

16 l

06S

-0.44 l

l 48 l

24 l

12 l 07S

+0.47 l

49 l

59 l

10 l OSS

+0.48 l

49 l

121 l

12 l

OSS

-0.05 l

50 l

2 l

12 l 09S

+0.62 l

50 l

11 l

19 l 09S

+0.61 l

l 50 l

67 l

15 l 06S

+0.23 l

l 52 l

50 l

12 l OSS

+0.53 l

l 52 l

65 l

3 l 06S 40.62 l 52 l

67 l

12 l OSS

+0.64 l

52 l

67 l

4 l 06S

+0.80 l

52 l

67 l

6 l 07S

+0.72 l

1 52 l

73 l

6 l 06S

+0.54 l

j l

53 l

68 l

9 l 06S

+0.71 l

l 54 l

56 l

11 l OSS 40.67 l l

54 l

64 l

3 l OSS

+0.61 l

54 l

75 l

8 l 05S

+0.58 l

54 l

118 l

7 l

06S

-0.19 l

54 l

126 l

11 l 09S

+0.32 l 55 l

55 l

9 l 06S 40.62 l 55 l

55 l

7 l

06S

-0.24 l

55 l

67 l

7 l 06S

+0.26 l

57 l

64 l

7 l 05S

+0.46 l

57 l

69 l

6 l OSS

+0.73 l

57 l

70 l

13 l 06S

+0.36 l

58 l

128 l

12 l

10S

+0.45 l

60 l

77 l

8 l 06S

+0.00 l

60 l

87 l

10 l

15S

+0.85 l

60 l

98 l

13 l 06S

+0.69 l

61 l

100 l

17 l 05S

+0.66 l

62 l

111 l

7 l

08S

-0.65 l

62 l

126 l

10 l

09S

-0.65 l

63 l

89 l

20 l

06S

-0.64 l

63 l

124 l

8 l

08S

-0.31 l

Attachment ta 1CAN069806 Page 108 cf127 Table 9 (cont)

"A" OTSG Tube Support Plate Mechanical Wear l

65 l

41 l

22 l 06S

+0.67 l

l 65 l

77 l

14 l

06S

-0.49 l

l 65 l

83 l

7 l

06S

-0.36 l

l 65 l

123 l

7 l 08S

+0.68 l

l 66 l

109 l

18 l

07S

-0.31 l

l 66 l

125 l

12 l 08S

+0.48 l

l 66 l

126 l

15 l 08S

+0.61 l

l 67 l

114 l

17 l 06S

+0.62 l

l 67 l

119 l

15 l 06S

-M).65 l

l 68 l

3 l

8 l 09S

+0.63 l

l 68 l

28 l

11 l 09S

+0.69 l

l 68 l

l 19 l 06S 40.13 l

l 69 l

98 l

5 l 06S

+0.71 l

l 69 l

122 l

17 l 06S

+0.67 l

l 70 l

73 l

11 l

06S

-0.01 l

l 70 l

98 l

5 l 06S

+0.61 l

l 70 l

116 l

12 l 06S 40.49 l l

70 l

125 l

12 l 08S

+0.60 l

l 70 l

126 l

9 l 08S

+0.67 l

l 71 l

64 l

6 l 08S

+0.10 l

l 71 l

67 l

6 l 07S

+0.60 l

l 71 l

91 l

19 l 06S

+0.50 l l

71 l

105 l

19 l 06S

+0.72 l

l 71 l

115 l

12 l 06S

+0.70 l

l 71 l

131 l

11 l

10S

+0.58 l

l 72 l

46 l

10 l 07S

+0.69 l

l 72 l

71 l

9 l 07S

+0.29 l

l 72 l

71 l

11 l

08S

-0.11 l

l 72 l

130 l

14 l

10S

+0.68 l

l l

73 l

59 l

12 l 09S

+0.70 l

l 73 l

69 l

15 l

llS 4 0.73 l l

l 73 l

83 l

10 l

06S

-0.33 l

l 73 l

117 l

13 l 06S

+0.70 l

l 73 l

119 l

, 11 l 06S 40.77 l l

74 l

30 l

18 l 08S

+0.53 l

l 74 l

115 l

13 l 06S

+0.73 l

l 74 l

116 l

17 l 06S

+0.65 l

l 75 l

90 l

12 l

06S

-0.07 l

I

Atuamaat to '

ICAN069806 Page 109 of127 Table 9 (cost) l "A" OTSG Tube Support Plate Mechanical Wear l

l 75 l

118 l

12 l 06S

+0.52 l

76 l

68 l

8 1 06S

+0.38 l

76 l

109 l

19 l 06S

+0.56 1

76 l

110 l

21 l 06S

+0.52 l

76 l

122 l

10 l

08S

-0.21 l

77 l

68 l

6 l

09S

-0.62 l

77 l

68 l

16 l

095

-0.62 i

l 77 l

71 l

5 l

06S

-0.56 l

77 l

71 l

17 l

06S

-0.56 l

78 l

69 l

11 l 06S

+0.18 l

78 l

69 l

18 l

06S

-0.18 l

79 l

29 l

14 l

lIS

-0.43 l

79 l

36

l 19 l

lIS

+0.56 l

79 l

80 l

15 l 03S

%.48 4

)

l 79 l

121 l

10 l 06S

+0.63 l

80 l

51 l

24 l 07S

+0.67 d

l 80 l

51 l

23 l OSS

%.38 l

80 l

53 l

20 l 07S

+0.69 l

80 l

53 l

28 l

07S

-0.71 i

l 80 l

53 l

23 1 08S 40.52 l

80 l

58 l

16 l

08S

-0.64 l

82 l

7 l

14 l OSS

+0.66 l

82 l

27 l

15 l

13S

+0.73 l

82 l

52 l

17 l 08S

+0.34 l

82 l

52 l

16 l

08S

-0.74 l

82 l

56 l

7 l

08S

-0.71 l

82 l

127 l

16 l

07S

-0.84

'l 83 l

45 l

13 l

09S

-0.69 l

83 l

50 l

16 l

09S

-0.38 l

83 l

50 l

17 l

09S

-0.66 l

83 l

53 l

16 l

08S

-0.56 l

84 l

5 l

24 l OSS

+0.34 l

84 l

11 l

15 1 06S

+0.33 1

l 84 l

77 l

13 l

06S

-0.65

)

1 84 l

82 l

11 l 06S

+0.29 l

85 l

37 l

10 l

09S

-0.75 l

85 l

94 l

12 l %S

+0.30

)

1 86 l

9 l

17 l

10S

-0.71 l

Attachment to ICAN%9806 Page 110 Cf127 i

Table 9 (cont)

"A" OTSG Tube Support Plate Mechanical Wear 032 10S l

86 l

13 l

16 IOS

-0.75 l

86 l

16 l

11 10S

-0.76 l

87 l

12 l

20 10S

-0.48 l

87 l

22 l

15 08S

+0.11 l

87 l

58 l

7 OSS

+0.55 l

91 l

5 l

17 08S

+0.46 l

93 l

2 l

13 095

+0.60 l

95 l

53 l

23 03S

+0.12 l

95 l

109 l

13 OSS

+0.30 l

98 l

59 l

27 05S

+0.60 l

98 l

64 l

15 OSS

+0.62 l

99 l

60 l

30 OSS

+0.50 l

100 l

20 l

23 15S

+0.75 l

100 l

62 l

12 OSS

+0.54 l

101 l

69 l

17 OSS

+0.61

]

l 101 l

76 l

17 06S

-0.29 l

101 l

108 l

11 06S

+0.3 3 l

102 l

45 l

7 03S

+0.25 l

102 l

95 l

18 14S 40.45 l

103 l

71 l

15 06S

+0.15 l

l 103 l

119 l

8 09S

-0.65 l

104 l

8 l

16 06S

+0.54 l

l 104 l

39 l

18 07S

+0.62 l

105 l

40 l

13 07S

+0.13 l

105 l

71 l

8 08S

-0.65 l

105 l

73 l

9 06S

-0.28 l

105 l

80 l

9 12S

+0.35 l

106 l

4 l

11 07S

+0.46 l

106 l

4 l

25 10S

+0.63 l

106 l

8 l

14 06S

+0.52 l

106 l

66 l

13 OSS

+0.52 l

107 l

2 l

12 08S

+0.45 l

107 l

54 l

7 07S

+0.22 l

107 l

69 l

11 06S

+0.48 l

108 l

50 l

9 05S

+0.47 l

108 l

54 l

13 OSS

+0.50 l

108 l

68 l

17 06S

-0.06 l

109 l

1 l

13 OlS

-0.66 l

l L_____--______________-

Attachment to 1CAN069806 Page111 of127 Table 9 (cont)

"A" OTSG Tube Support Plate Mechanical Wear 109 l

41 l

13 l 07S

+0.60 l

110 l

51 l

23 l OSS

+0.61 l

110 l

90 l

16 l 06S

+0.43 l

111 l

53 l

18 l 05S

+0.48 l

111 l

58 l

15 l OSS

+0.57 l

112 l

80 l

15 l 07S

+0.15 l

113 l

3 l

21 l 08S

+0.44 l

114 l

44 l

14 l 07S

+0.31 l

115 l

4 l

20 l 08S

+0.40 l

115 l

8 l

37 l 08S

+0.42 l

115 l

50 l

17 l 06S

+0.16 l

116 l

6 l

16 l

10S

-0.28 l

116 l

31 l

17 l 07S

+0.56 l

119 l

37 l

11 l

07S

-0.29 l

119 l

42 l

11 l

07S

-0.33 l

120 l

47 l

21 l 06S

+0.63 l

122 l

49 l

7 l 06S

+0.59 l

123 l

93 l

11 l 06S

+0.72 l

124 l

67 l

19 l 06S

+0.54 l

13*

l 30 l

12 l

07S

-0.47 l

132 l

83 l

24 l

10S

-0.68 l

133 l

61 l

15 l 07S

+0.00 l

135 l

2 l

30 l

IOS

+0.67 l

137 l

76 l

18 l 09S

+0.41 l

143 l

49 l

15 l 03S

+0.3 5 l 143 l

49 l

14 l 03S

+0.41 l

148 l

7 l

12 l 08S 40.14 l 149 l

2 l

11 l 09S 40.32 l 149 l

27 l

9 l

10S

+0.62 l

149 l

28 l

16 l

10S

+0.59 l 149 l

28 l

10 l

10S

-0.82 l

150 l

10 l

15 l

10S

+0.62 l

150 l

12 l

13 l

10S

+0.64 l

150 l

18 l

22 l

10S

.O.63 l

150 l

20 l

19 l

10S

+0.55 l

150 l

21 l

17 l

10S

+0.73 l

150 l

21 l

15 l

10S

-0.60 l

151 l

5 l

16 l

IOS

+0.62 l

Attachment to ICAN069806 Page 112 of127 Table 9 (cont)

"A" OTSG Tube Support Plate Mechanical Wear l

151 l

10 l

13 l

07S

-0.78 l

l 151 l

15 l

25 l

10S t0.63 l

\\

l l

l

Attachment to ICAN0698%

Page 113 of127 Table 10 "B" OTSG Tube Supped Plate Mechanical Wear 3

33

-0.77 4

1 l

14 l

lIS 0.65 4

21 l

11 l

14S

-0.74 5

3 l

14 l

llS

+0.68 5

16 l

16 l

10S

+0. 53 6

15 l

15 l

10S

+0.52 7

13 l

21 l

09S

-0.68 7

44 l

10 l 09S

+0.16 10 8

l 12 l

IOS

-0.67 11 6

6 l

08S

-0.15 12 66 9

l 07S

-0.51 12 70 15 l

IIS

+0.47 12 71 14 l

lIS

+0.50 13 1

10 l

OSS

-0.72 l

13 2

10 l 07S

+0.61 14 6

5 l

06S

-0.30 15 56 11 l

10S

-0.67 15 73 6

l 07S

-0.54 16 2

11 l

14S

-0.68 16 11 13 l

08S

-0.72 16 75 7

l 10S

+0.41 18 85 5

l 03S

-0.66 19 48 15 l 07S

+0.35 21 82 5

l 06S

-0.23 22 43 17 l 03S

+0.52 23 32 18 l

10S

-0.75 23 83 9

l 14S

-0.60 i

23 91 6

l OSS

-0.54 24 1

20 l 03S

+0.67 27 44 18 l 05S

+0.23 29 70 12 l

07S

-0.50 30 11 14 l

14S

%.00 32 19 18 l

07S

-0.41 l

33 43 13 l 07S

+0.16 l

33 107 6

l 10S

-0.58 33 108 9

l 14S

-0.67 34 20 23 l

OSS

-0.52 34 25 20 l

07S

-0.24 34 36 9

l 07S

-0.18

Attachment to 1CAN069806 Page 114 of127 Table 10 (cont)

"B" OTSG Tube Support Plate Mechanical Wear l

34 l

107 l

12 l 08S 40.61 l

36 l

13 l

13 l

lIS

-0.53 l

36 l

20 l

9 l

05S

-0.01 l

36 l

102 l

10 l

15S

+0.75 l

36 l

111 l

7 l 08S

+0.10 l

36 l

111 l

9 l 08S

+0.63 l

36 l

113 l

15 l

14S

-0.49 l

37 l

114 l

9 l

07S

-0.75 l

39 l

98 l

8 l

13S

-0.72 l

40 l

2 l

13 l

10S

+0.70 l

40 l

50 l

13 l 06S

+0.44 l

41 l

110 l

6 l

12S

+0.51 l

41 l

110 l

12 l

12S

+0.60 l

41 l

110 l

17 l

13S

+0.46 l

41 l

110 l

29 l

14S

-0.64 l

42 l

4 l

22 l

08S

-0.59 l

43 l

30 l

16 l 07S

+0.60 l

44 l

54 l

21 l

10S

-0.71 l

44 l

92 l

10 l

08S

-0.71 l

47 l

9 l

11 l

05S

-0.64 l

47 l

9 l

12 l

05S

-0.70 l

47 l

32 l

10 l

07S

-0.23 l

47 l

119 l

10 l

09fi

-0.56 l

48 l

110 l

9 l

14S

+0.56 l

48 l

118 l

13 l

08S

-0.70 l

49 l

35 l

10 l

09S

-0.70 l

49 l

119 l

9 l

08S

-0.60 l

50 l

6 l

24

~

14S

-0.69 l

50 l

35 l

22 07S

-0.65 l

50 l

119 l

13 14S

-0.75 l

51 l

6 l

19 14S

-0.66 l

52 l

1 l

12 IIS

+0.64 l

55 l

95 l

10 06S

+0.69 l

55 l

122 l

5 14S

-0.65 l

57 l

29 l

7 05S

+0.67 l

59 l

37 l

11 07S

-0.63 l

59 l

93 l

5 06S

+0.40 l

59 l

122 l

10 07S

-0.35

Attachment to 1CAN069806 Page 115 Ef127 Table 10 (coat)

"B" OTSG Tube Support Plate Mechanical Wear l

l 61 l

1 l

21 l

14S

-0.65 l

l 62 l

3 l

15 l

09S

-0.26 l

l l

62 l

27 l

8 l

07S

-0.20 l

l 62 l

71 l

14 l

06S

-0.02 l

l 63 l

26 l

19 l 07S

%.00 l l

63 l

124 l

12 l

04S

-0.76 l

l 64 l

126 l

17 l 09S

+0.63 l

l 67 l

29 l

4 l 07S

+0.66 l

l 67 l

47 l

18 l 03S

+0.14 l

l 68 l

26 l

10 l

10S

-0.64 l

l 68 l

115 l

7 l 06S

+0.10 l

l l

69 l

21 l

10 l 09S

+0.56 l

l 69 l

53 l

12 l 06S

+0.17 l

l l

70 l

47 l

9 l

04S

-0.78 l

l 70 l

47 l

16 l

08S

-0.79 l

l 71 l

24 l

13 l

04S

-0.03 l

l 71 l

43 l

11 l 07S

%.36 l l

72 l

31 l

10 l 09S 40.67 l l

72 l

64 l

18 l 08S

%.63 l l

72 l

64 l

9 l

08S

-0.35 l

1 l

l 72 l

88 l

5 l 06S

+0.33 l

l l

73 l

31 l

13 l

105

-0.73

]

l 73 l

126 l

14 l 07S

+0.69 l

l 74 l

3 l

9 l

13S

-0.36 l

l 75 l

9 l

17 l

13S

+0.67 l

l 75 l

9 l

17 l

14S

+0.65 l

l 76 l

119 l

12 l

OSS

-0.75 l

l 78 l

24 l

9 l

04S

-0.78 l

l 79 l

7 l

17 l 08S

+0.59 l

l 79 l

29 l

8 l

10S

-0.80 l

l 79 l

46 l

9 l

09S

-0.43 l

l 79 l

59 l

8 l

10S

+0.39 l

l l

79 l

66 l

6 l

OlS

-0.68 l

l 79 l

112 l

6 l

05S

-0.76 l

l 80 l

87 l

10 l 06S

+0.59 l

I l

l 81 l

26 l

10 l

09S

-0.83 l

l 81 l

27 l

11 l

OSS

-0.64 l

l 81 l

56 l

7 l

07S

-0.19 l

I Attachment to 1CAN069806 l

Page 116 ef127 Table 10 (cont)

"B" OTSG Tube Supped Plate Mechanical Wear f

I

+0.74 81 l

80 l

20 l

06S

-0.44 82 l

1 l

11 l

07S

-0.82 82 l

128 l

6 l 08S

+0.44 83 l

1 l

13 l

lIS

-0.82 83 l

21 l

4 l

10S

-0.79 83 l

118 l

8 l

02S

-0.04 83 l

118 l

7 l

02S

-0.30 83 l

130 l

11 l 08S

+0.04 84 l

126 l

11 l

04S

-0.51 85 l

39 l

11 l 06S

+0.1 1 85 l

69 l

10 l

OSS

-0.72 85 l

114 l

8 l 04S

+0.77 86 l

84 l

14 l 05S

+0.50 i

87 l

118 l

8 l

04S

-0.70 87 l

130 l

7 l

14S

+0.64 88 l

50 l

8 l 06S

+0.59 89 l

18 l

6 l 08S 40.71 90 l

21 l

4 l

10S

-0.82 90 l

31 l

8 l

07S

-0.37 i

91 l

126 l

13 l

06S

-0.74 I

93 l

1 l

6 l 08S

+0.66 l

66 l

9 l

05S

-0.78 101 l

68 l

11 l

12S

-0.53 103 l

47 l

7 l 06S

+0.10 103 l

58 l

18 l

OSS

-0.73 103 l

110 l

3 l

08S

-0.45 104 l

35 l

17 l

05S

-0.25 105 l

119 l

14 l

14S

-0.57 107 l

37 l

10 l

02S

-0.85 107 l

115 l

11 l

14S

-0.69 108 l

106 l

4 l

ISS

+0.53 110 l

56 l

7 l

OSS

-0.75 110 l

113 l

12 l

13S

+0.61 110 l

113 l

15 l

13S

-0.63 110 l

115 l

18 l

13S

-0.62 111 l

113 l

12 l 09S

+0.60 112 l

84 l

7 l

OSS

-0.78 113 l

57 l

9 l

OSS

-0.73 l

l E

Attachment to 1CAN069806 I

Page 117 cf127 l

l Table 10 (cont)

"B" OTSG Tube Suppod Plate Mechanical Wear l

l 113 l

111 l

10 l 09S

+0.21 l

l 114 l

31 l

7 l

07S

-0.15 l

l 114 l

109 l

9 l 09S 40.32 l l

114 l

112 l

6 l 09S

+0.74 l

l 115 l

108 l

6 l 09S

+0.31 l

l 115 l

108 l

11 l 09S 40.72 l l

116 l

109 l

11 l 09S

+0.57 l

l 116 l

109 l

18 l

13S

-0.79 l

l 117 l

78 l

9 l

06S

-0.77 l

I l

118 l

27 l

7 l 02S

+0.00 l

l 118 l

103 l

10 l 09S

+0.68 l

I l

119 l

69 l

19 l

06S

-0.71 l

l l

119 l

106 l

20 l 09S

+0.55 l

l 121 l

39 l

12 l

06S

-0.80 l

)

l 121 l

95 l

6 l OSS

+0.41 l

l l

122 l

29 l

9 l

04S

-0.72 l

l l

122 l

39 l

9 l

07S

-0.50 l

l 125 l

l 11 l 09S

+0.78 l

l 125 l

97 l

13 l 09S

+0.83 l

l 126 l

l 11 l 09S

+0.71 l

l 127 l

91 l

16 l

06S

-0.73 l

l 129 l

3 l

15 l

10S

+0.67 l

l l

130 l

2 l

16 l

10S

+0.66 l

l 130 l

9 l

10 l

02S

-0.75 l

l 130 l

28 l

9 l 07S

+0.69 l

l 131 l

1 l

13 l

10S

+0.63 l

l l

131 l

7 l

10 l 06S

-0.77 l

l 131 l

43 l

11 l

05S

-0.79 l

l 132 l

1 l

13 l

10S

+0.72 l

l 132 l

26 l

13 l

02S

-0.78 l

l 132 l

27 l

8 l

06S

-0.75 l

l 133 l

3 l

16 l

10S

-0.64 l

l l

133 l

26 l

10 l 05S

+0.76 l

l 133 l

26 l

14 l

OSS

-0.76 l

l 134 l

2 l

10 l

10S

+0.68 l

l 134 l

24 l

10 l

02S

-0.76 l

l 136 l

4 l

15 l

10S

+0.62 l

l 137 l

3 l

15 l 09S

+0.70 l

Attachment to ICAN069806 j

Page 118 cf127 Table 10 (cont)

"B" OTSG Tube Support Plate Mechanical Wear 1

1 l

141 l

9 l

7 l

06S

-0.47 l

l l

142 l

3 l

11 l 09S

+0.69 l

142 l

3 l

13 l

10S

+0.66 l

142 l

55 l

9 l

08S

-0.06 l

143 l

1 l

9 l

08S

-0.77 l

143 l

23 l

14 l

13S

-0.75 l

144 l

9 l

7 l

07S 4.45 l

l 145 l

7 l

5 l 06S

+0.25 l

l 146 l

8 l

11 l 08S 40.78 l

146 l

10 l

12 l

08S

-0.65 l

146 l

16 l

10 l

lIS

-0.67 l

146 l

34 l

10 l

14S

-0.72 l

146 l

35 l

11 l

13S

+0.65 l

l 147 l

1 l

13 l 08S

+0.68 l

147 l

3 l

6 l

06S

-0.77 l

l 147 l

15 l

9 l

13S

+0.57 I

l 147 l

15 l

25 l

13S

-0.68 l

147 l

27 l

12 l 09S

+0.72 l

l 147 l

41 l

14 l

06S

-0.75 l

147 l

44 l

9 l 07S

+0.04 l

148 l

7 l

4 l

06S

-0.78 l

148 l

7 l

21 l 08S

+0.75 l

149 l

1 l

7 l

06S

-0.70 l

149 l

1 l

21 l 08S

+0.65 l

149 l

3 l

14 l

06S

-0.75 l

149 l

14 l

17 l

10S

+0.64 l

149 l

16 l

16 l

10S 40.68 l

149 l

19 l

13 l

10S

+0.73 l

l 150 l

8 l

6 l

10S

+0.68 l

l 150 l

14 l

14 l

11S

-0.76 l

150 l

16 l

16 l

10S 40.65 1

150 l

16 l

11 l

iOS

-0.73 l

150 l

16 l

9 l

IIS

-0.72 l

150 l

17 l

12 l

10S

+0.71 l

150 l

23 l

13 l

10S 40.73 l

l 151 l

1 l

8 l

06S

-0.71 l

l 1

i l

I Attachment to 1CAN069806 j

Page 119 of127 Table 11 I

"A" OTSG Miscellaneous Indications l

1 1

11 l

SAI l

ISS

-1.25 1

11 l

SAI l

ISS

-1.97 l

1 14 l

SAI l

14S

+2.44 2

15 l

SAI l

10S

+29.37 2

15 l

SAI l

10S

+31.86 2

15 l

SAI l

10S

+33.10 17 37 l

SAI l

UTE

-3.04 l

21 84 l

SVI l

OSS

+0.36 35 16 l

SAI l

ISS

-5.38 35 49 l

SAI l

UTE

-3.22 74 53 l

SVI l

UTS

+0.22 74 66 l

SVI l

12S

+2.71 74 66 l

SVI l

12S

+2.71 74 66 l

SVI l

12S

+5.03 74 66 l

SVI l

12S

+5.03 75 66 l

SVI l

12S

+1.56 75 66 l

SVI l

12S

+1.92 75 69 l

SVI l

LTS

+0.66 76 73 l

SVI l

LTS

+1.65 77 70 l

SVI l

LTS

+0.90 79 25 l

SAI l

15S

+21.93 80 61 l

SVI l

UTE

-3.06 81 49 l

SAI l

UTS

+0.83 81 53 l

SAI l

ISS

-6.35 81 75 l

SVI l

LTS

+0.57 84 79 l

SVI l

OlS

+26.88 89 59 l

SVI l

03S H).ll 99 24 l

SVI l

UTE

-4.20 100 22 l

MAI l

15S

+24.83 100 22 l

MAI l

ISS

+26.09 100 22 l

MAI l

15S

+27.17 i

100 22 l

MAI l

ISS

+27.29 s

102 15 l

SVI l

lIS

+11.84 104 15 l

SVI l

ISS

+0.79 109 19 l

SAI l

ISS

+1.42 109 19 l

SAI l

ISS

+2.91 I

109 19 l

SAI l

15S

+3.82 109 19 l

SAI l

15S

+8.35 i

O l

Attachment to ICAN069806 I

Page 120 of127 Table 11 (cont)

"A" OTSG Miscellaneous Indications l

109 l

19 l

SAI l

ISS

+14.05 l

109 l

19 l

SAI l

15S

+39.83 J

l 112 l

17 l

SAI l

14S

+23.26 l

127 l

98 l

SAI l

14S

+17.75 l

l 127 l

98 l

SAI l

14S

+19.13 l

127 l

98 l

SAI l

ISS

+4.33 1

l 131 l

58 l

SVI l

ISS

+0.73 l

135 l

63 l

SAI l

12S

-8.63 l

135 l

63 l

SAI l

12S

-9.02 l

135 l

69 l

SVI l

03S

-0.14 l

137 l

61 l

SAI l

14S

+5.49 l

137 l

61 l

SAI l

14S

+6.68 l

137 l

61 l

SAI l

14S

+7.20 l

l 137 l

61 l

SAI l

14S

+9.78 l

138 l

43 l

SVI l

05S

-0.41 l

139 l

58 l

SVI l

13S

+4.88 l

139 l

58 l

SAI l

13S

+8.34 l

139 l

58 l

SAI l

13S

+9.23 l

147 44 l

SVI l

OSS

+1.44 l

147 46 l

SAI l

11S

+13.80 l

147 46 l

SAI l

lIS

+6.18 l

147 46 l

SAI l

lIS

+7.15 l

147 46 l

SAI l

11S

+8.83 l

147 46 l

SAI l

lIS

+9.72 l

147 46 l

SAI l

lIS

+11.01 1

l 148 38 l

SVI l

OSS

+1.48 4

O i

l l

Attachment to ICAN069806 Page 121 of127 Table 12 "B" OTSG Miscellaneous Indications l

19 l

3 l

SAI l

10S

+0.17 l

l 29 l

44 l

SAI l

LTS

+0.27 l

l 44 l

21 l

SVI l

10S

+9.64 l

l 48 l

79 l

SVI l

UTE

-4.80 l

l 52 l

87 l

SV1 l

15S

+30.82 l

l 75 l

63 l

SVI l

09S

+3.35 l

I l

87 l

54 l

SAI l

15S

+36.40 l

)

l 92 l

116 l

SVI l

UTE

-3.51 l

l l

l 22 l

SAI l

UTS

+0.40 l

j l

96 l

3 l

SAI l

UTS

+0.97 l

j l

97 l

14 l

SVI l

14S

+2.66 l

j l

127 l

2 l

SAI l

14S

+30.17 l

)

l 127 l

2 l

SAI l

14S

+30.50 l

l 127 l

2 l

SAI l

15S

+ 1.62 l

l 129 l

3 l

SAI l

15S

+4.3 8 l

1 l

129 l

3 l

SAI l

ISS

+4.62 l

l 129 l

3 l

SAI l

ISS

+6.10 l

l 131 l

1 l

SAI l

15S

+1.98 l

l 131 l

1 l

SAI l

15S

+3.54 l

l 131 l

1 l

SAI l

15S

+3.79 l

l 131 l

1 l

SAI l

15S

+4.64 l

l 131 l

1 l

SAI l

15S

+5.65 l

l 131 l

1 l

SAI l

15S

+6.57 l

l 131 l

1 l

SAI l

15S

+6.80 l

l 131 l

1 l

SAI l

ISS

+7.06 l

l 131 l

1 l

SAI l

15S

+7.87 l

1 l

j

Attachment to 1CANM9806 Page 122 cf127 Table 13 1R14 Tubes Plugged /Stabilised la the "A" OTSG i

6

!l 51 1

N/A 1 PTP ll 1

Addit. Roll Plug 7

l 29 l

N/A l PTP l l

Addit. Roll Plug 11 l

3 l

N/A l PTP l l

Addit. Roll Plug l

24 1 35 l

N/A l PTP l l Addet. Roll Plug 32 l 95 l

N/A l PTP l l

Addit. Roll Plug 37 l 97 l

N/A l PTP l l

Addit. Roll Plug 38 l 57 l

N/A l PTP l l

Addit. Roll Plug 38 l 103 l N/A l PTP l l

Addit. Roll Plug 42 l 1

l N/A l PTP l l Addit. Roll Plug 46 l 108 l N/A I PTP l l

Addit. Roll Plug 49 l 111 l N/A l PTP l l

Addit. Roll Plug 58 l 13 l

N/A l PTP l l

Addit. Roll Plug 59 l 2

l N/A l PTP l Sleeve Plug l

Existing Plug 64 l 103 l N/A l PTP l l

Addit. Roll Plug 65 l 14 l

N/A l PTP l l Addit.' Roll Plug 65 l 16 l-N/A l - PTP l l Addit. Roll Plug 67 l 23 l

N/A l PTP l Sleeve Plus l

Existing Plug 70 l 1

l N/A l PTP l l Addit. Roll Plug 71 l

1 l

N/A l PTP l l Addit. Roll Plug 72 l 2

l N/A l PTP l l Addit. Roll Plug -

73 l

2 l

N/A l PTP l l Addit. Roll Plug 73 l

4 l

N/A l PTP l l Addit. Roll Plug 74 l 1

l N/A l PTP l l Addit. Roll Plug -

74 l 2

l N/A l PTP l l Addit. Roll Plug 74 l 87 l

N/A l PTP l l Addit. Roll Plug 75 l 1

l N/A l PTP l l Addit. Roll Plug 75 l 3

l N/A l PTP l l Addit. Roll Plug 75 l 15 l

N/A l PTP l l

Addit. Roll Plug 75 l 27 l

N/A l PTP l l

Addit. Roll Plug 77 l 13 l

N/A l PTP l l

Addit. Roll Plug 77 l 17 l

N/A l PTP l l

Addit. Roll Plug 77 l 18 l

N/A l PTP l l

Addit. Roll Plug 77 l 27 l

N/A l PTP l l Addit. Roll Plug 77 l 63 l

N/A l PTP l l Addit. Roll Plug l,

78 l 62 l

N/A l PTP l l

Addit. Roll Plug i

79 l 6

l N/A l PTP l l Addit. Roll Plug 79 l 7

l N/A l PTP l l

Addit. Roll Plug 79 l 62 l

N/A l PTP l l

Addit. Roll Plug 80 l 5

l N/A I PTP l l Addit. Roll Plug

ytseognuoulas 10VN096809 ds93 ttE oJ1ZL iuqta lg )aesU INIF 18988 dlaSSeP/S189!!!88P 18 848,,V= 01SD SO II S

U N/V ll did l

j ypp! yolldgnu p SI l 90 l

N/V l did l l

YPPT 10 1 dine l I

l SE l. t~ l N/V l did l l

VPP!1 1011 ains I l

l _ SL l SI l

N/V l did l l

VPPT Monains l l

l 65 [

lE 7l N/V l did l.

Siosae dins l

3x!situB dinB l

l 6L l N/V l did l l

YPP!* noil dI"8 l IES l I19 l I11 l N/V l did l l

VPPT 1011 dins l

)

l !zt l t

l N/V

[ did l l

VPPP MoH dins l l ttO l 98 l

N/V l did l l

VPPT 1011 dins l l

I l

11 I.ISS

-i tS I SVI I S291011ains l ueil dias l

l 1

l 19-l ltS

+t tt l SVI I Ssuq noilains l uoildins l

l t

l 15 l IOS

+t6'EL l SVI I

won dias I

noilains l

l z1 l

SF lOSS

+O'E9 l SAI l

Woli dins l

uoil ains l

l ES l 19 lISS

-5ESl SVI l

uoti ains I

uoti dins I

f l

l tt l I10 lMS

+O'E6 l A01 l S19' 101[ dins l yo(( dins l

l PL l t

lMS

+l0~94 l AOI" l Woii dins l

uoildins I

l tS l IIP lES

+0'65 l AOI' l S39' Moii dins I uoil ains l

1 l

l S1 l I19 lmS

+S't9 l AOI" l 10 1 dins l

Moil dine l

l SE l 106 lm3

-0'tE l SHV l 1011 dins l

HOii dins l

l SL l lt9 l ISS

+t'96l AOl' l 4011 dins l

1011 dins l

l 91 l

fO lmS

+L'6z l AOI' l S19 noiiains I noilains I

l 9Z l llE l ISS

+l'0El A01 I S uq uotidins I uoti dins l

l 9t l !!t I ltS

+l zE l AOI' I 1011 dla8 I

uoil din 8 1

l 95 l

SL lMS

+S'99 l AOi' l S uq uoil dinu I noilains l

l 96 l fO lm3

-lE'LI l A01 l 1011 dins l

uoii dins l

l 96 l SP lMH

-10'EL l AOl' l 1011 dine l

1011 dins l

l 40 l tI lMH

-0'15 l M3V l 1011 dins l

1011 dins l

l LI l

16 lmS

+ 9'SE l A O I" l

1011 dins l

MoH dins l

l 41 l

SL lMS

+O'LS l AOI" l S1=q' 1011 dins l Woil dins l

l.49 l SE lMS

+O'tI l SAI l S19' 1011 dins l Moil dins l

l LF l

99 lmS

+O'98 l A01 l S19' 4011 dins l 1011 dinv l

l LW l 99 l lzS

+t'LI l SAI l

Woil dins l

Moil dinB l

l ' LS l 99 l IIS

+I'59l SAI l

Moii dins l

1011 dine l

l LS l

96 lI'1S

+O'99 l SAI l

Woigains l

S vq 3011dinu I

l 49 l LE lI'1S

+I'95 l SAI l

1011 dins l

S:89' 1011 dinB l

l tt I tO l IIS

+0 60 I SAI l

noildins l

Sivq' uoli dins l

l LS l 99 lMS

+0'88 l A01 l S19' Holi dins l Woii dins l

l 46 I tS I ISS

+tI 6t I SVI l

uoil dins I

uolf di"8 1

l 80 l it lmS

+t'59 l A01 l 1011 diar l

M011dinB l

i

Attachment ts 1CAN069806 Page 124 Cf127 Table 13 (cont) 1R14 Tubes Plugged / Stabilized in the "A" OTSG l

pm E ggY'fYr79 Q iM 81 48 UTS

+0.31 VOL Stab. Roll Plug Roll Plug 81 49 UTS

+0.83 SAI Stab. Roll Plug Roll Plug l

81 53 ISS

-6.35 SAI Sleeve Plug Roll Plug i

81 55 UTS

+11.83 VOL Roll Plug Roll Plug

(

81 75 LTS

+0.57 SVI Roll Plug Stab. Roll Plug 82 67 UTE

-0.25 NCR/

Roll Plug Roll Plug Re-Roll 83 17 UTS

+0.44 VOL Stab. Roll Plug Roll Plug 84 79 OlS

+26.88 SVI Roll Plug Roll Plug 87 74 UTE

-3.06 NCR/

Roll Plug Roll Plug i

Re-Roll 89 52 UTE

-1.91 MAI Roll Plug Roll Plug 89 59 03S

%.11 SVI Roll Plug Roll Plug 90 3

UTS

+1.08 VOL Stab.. Roll Plug Roll Plug 91 2

UTS

+1.04 VOL Stab. Roll Plug Roll Plug 91 56 UTS

+15.04 VOL Roll Plug Roll Plug 92 2

UTS

+0.85 VOL Stab. Roll Plug Roll Plug 92 4

UTS

+7.39 VOL Roll Plug Roll Plug 92 11 UTS 40.79 VOL Stab. Roll Plug Roll Plug 94 2

UTS

+1.09 VOL Stab. Roll Plug Roll Plug 99 24 UTE

-4.20 SVI Roll Plug Roll Plug j

100 22 ISS

+27.29 MAI Roll Plug Roll Plug 102 15 1IS

+11.84 SVI Roll Plug Roll Plug 104 15 ISS

+0.79 SVI Stab. Roll Plug Roll Plug l

107 14 UTS

+6.48 VOL Roll Plug Roll Plug 109 19 15S

+1.42 SAI Stab. Roll Plug Roll Plug 112 17 14S

+23.26 SAI Roll Plug Roll Plug 115 114 UTS

+1.30 VOL Stab. Roll Plug Roll Plug 127 98 ISS

+4.33 SAI Stab. Roll Plug Roll Plug 131 58 ISS

+0.73 SVI Stab. Roll Plug Roll Plug 135 63 12S

-8.63 SAI Roll Plug Roll Plug 135 69 03S

-0.14 SVI Roll Plug Roll Plug 137 61 14S

+5.49 SAI Roll Plug Roll Plug 138 43 05S

-0.49 SCI Roll Plug Roll Plug 139 58 13S

+4.88 SVI Roll Plug Roll Plug 147 44 OSS

+1.44 SVI Stab. Roll Plug Roll Plug 147 46 1IS

+6.18 SAI Stab. Roll Plug Roll Plug 1

Attachment to ICAN0698%

Page 125 of127 l

Table 13 (cont) 1R14 Tubes Plugged / Stabilized la the "A" OTSG

~...

i L. Z. !l;;;;,.; J -* 6.'";....

148 38 OSS

+1.48 SVI Stab. Roll Plu Roll Plu 1

1 PTP = preventive tube plug VOL = volumetric indication SCI = single circumferential indication NCR = nonconformance report l

i l

Attachment ts ICAN069806 Page 126 of127 Table 14 1R14 Tubes Plugged /Stabilised la the "B" OTSG 27 36 L

N/A L PTP q L Remote Welded Plug u

l 27 l 39 l

N/A l PTP l l

Addit. Roll Plug l l 29 l 79 l

N/A l PTP l l Addit. Roll Plug l l

l 31 l 101 l N/A l PTP l l

Addit. Roll Plug l l 39 l 89 l

N/A l PTP l l

Addit. Roll Plug l l 41 l

l N/A l PTP l l

Addit. Roll Plug l l 42 l 98 l

N/A I PTP l l

Addit. Roll Plug l l 43 l 99 l

N/A l PTP l l

Addit. Roll Plug l l 44 l 49 l

N/A l PTP l l

Addit. Roll Plug l 1

l 65 l 6

l N/A I PTP l l

Addit. Roll Plug l l 73 l

8 l

N/A l PTP l l Addit. Roll Plug l l 73 l

9 l

N/A l PTP l l

Addit. Roll Plug l l 79 l 15 l

N/A l PTP l Sleeve Plug l

Existing Plug l

l 81 l

19 l

N/A l PTP l Sleeve Plug l

Existing Plug l

l 81 l

23 l

N/A l PTP l Sleeve Plug l

Existing Plug l

l l 82 l 23 l

N/A

] PTP l Sleeve Plug l

Existing Plug l

1 l 83 l

12 l

N/A l PTP l Sleeve Plug l

Existing Plug l

l 83 l

15 l

N/A l PTP l Sleeve Plus l

Existing Plug l

l 105 l 27 l

N/A l PTP l l Addit. Roll Plus l l 108 l 22 l-N/A l PTP l l

Addit. Roll Plug l l 112 l 19 I

N/A l PTP l l

Addit. Roll Plug l l 121 l 3

l N/A l PTP l Sleeve Plug l

Existing Plug l

l 12 l 45 l07S

-0.16 l SVI l

Roll Plug l

Roll Plug l

l 19 l 3

l 105

+0.17l SAI l

Stab Roll Plug l Roll Plug l

l 29 l 44 l LTS

+0.27 l SAI l Roll Plug l

Stab Roll Plug l

l I

l 37 l 114 lUTS

+21.92I VOL l Stab Roll Plug l Roll Plug l

l 44 l 21 l10S

+9.64 l SVI~l Roll Plug l

Roll Plug l

l 47 l 6

l UTS

+2.33 l VOL l Roll Plug l

Roll Plug l

l l 48 l 79 l UTE

-4.80 l SVI l

Roll Plug l

Roll Plug l

l 52 l 87 l 1SS

+30.82 l SVI l

Stab Roll Plug l Roll Plug l

i' l 55 l 2

lUTS

+2.61 l VOL l Roll Plug l

Roll Plug l

l 58 l 87 l UTS

+7.07 l VOL l Roll Plug l

Roll Plug l

I 64 l 51 lUTS

+4.85 l VOL l Roll Plug l

Roll Plug l

l l 68 l 25 lUTS

+2.75 l VOL l Roll Plug l

Roll Plug l

l l 72'l 43 l UTS

+2.34 l VOL l Roll Plug l

Roll Plug l

l l 74 l 35 l Roll Distortion l N/A l Roll Plug l

Roll Plus l

l 75 l 63 l09S

+3.35 l SVI l

Stab Roll Plug l Roll Plug l

l 78 l 69 l UTS

+2.10 l VOL l Roll Plug l

Roll Plug l

l 82 l 17 lUTS

+0.32 ] VOL l Stab Roll Plug l Roll Plug l

Attachment to 1CAN069806 l

Page 127 cf127 Table 14 (cont) l 1R14 Tubes Plugged / Stabilized in the "B" OTSG l

l Q.

M-

. cu r: 2 :MR 83 l

17 UTS

+2.65 l VOL Roll Plug Roll Plug 84 l 35 UTS

+0.41 l VOL Stab Roll Plug Roll Plug 87 l 54 ISS

+36.40 l SAI Roll Plug Roll Plug 89 l 12 UTS

+0.64 l VOL Stab Roll Plug Roll Plug 92 l 116 UTE

-3.51 l SVI Roll Plug Roll Plug 95 l 68 UTS

+20.60 l VOL Roll Plug Roll Plug 96 l 3

UTS

+0.97 l SAI Stab Roll Plug Roll Plug 96 l 22 UTS

+0.40 l SAI Stab Roll Plug Roll Plug 97 l 14 14S

+2.66 l SVI Roll Plug Roll Plug 103 l 17 UTS

+6.80 l VOL Roll Plug Roll Plug 127 l 2

ISS

+1.62 l SAI Stab Roll Plug Roll Plug 129 l 3

ISS

+4.38 l SAI Roll Plug Roll Plug 131 l 1

ISS

+1.98 l SAI Stab Roll Plug Roll Plug i

i I

l L

_ _ _ _ _ _ _ _ _