Semantic search

Jump to navigation Jump to search
Condition
Printout selection
Options
Parameters [
limit:

The maximum number of results to return
offset:

The offset of the first result
link:

Show values as links
headers:

Display the headers/property names
mainlabel:

The label to give to the main page name
intro:

The text to display before the query results, if there are any
outro:

The text to display after the query results, if there are any
searchlabel:

Text for continuing the search
default:

The text to display if there are no query results
class:

An additional CSS class to set for the table
transpose:

Display table headers vertically and results horizontally
sep:

The separator between results
prefix:

Control display of namespace in printouts
Sort options
Delete
Add sorting condition
 Issue dateTitleTopic
ML18025B77312 May 1982NPDES Noncompliance Notification:On 820502,collected Sample Containing 124 Mg/L of Suspended Solids Exceeded Daily Limit of 100 Mg/L.Caused by Failed Filter Sys.Filter Cartridges Replaced
ML18025B7858 June 1982NPDES Noncompliance Notification:On 820513,samples Taken of Sewage Treatment Plant Effluent Flow Exceeded Tech Spec Limit.Caused by Malfunctioning of Lift Pumps in Equalization Tank.Mod Proposals Being Reviewed
ML18025B89110 November 1982NPDES Noncompliance Notification:On 821029,condenser Cooling Water Sample Found to Have High Ph Content.Caused by Overflow from Sodium Hydroxide Storage Tank at Makeup Water Treatment Plant.Water Neutralized
ML18025B98926 July 1983NPDES Noncompliance Notification:On 830619,samples from Emergency Equipment Cooling Water Sys Contained Excessive Total Residual Chlorine Concentrations.Caused by Misaligned Valve in Chlorination Injection Sys
ML18025B99028 July 1983NPDES Noncompliance Notification:On 830712,grab Sample Collected & on 830718 Lab Repts Indicated Total Suspended Solids Exceeded Permit Limitations.Caused by Light,Inert Solids Washing Over Clarifier Weir Due to High FlowGrab sample
ML18025B99127 July 1983NPDES Noncompliance Notification:On 830708,condenser Cooling Water Pumping Station Discharge Ph Value Exceeded Max Limits.Cause Unknown But Suspected to Be from Sodium Hydroxide Flowing Into Gutter Drain While Unloading
ML18025B99830 August 1983Updated NPDES Noncompliance Notification Re 830619 Total Residual Chlorine (TRC) in Dsn 001.Provides Corrected Description of Discharge from Emergency Equipment Cooling Water Sys.No Detectable TRC Discharged to Tennessee River
ML18026A78921 November 1983NPDES Noncompliance Notification:On 831101,max Permit Limitations Exceeded.Caused by High Flows Overloading Sewage Treatment Capacity of Sewage Treatment Plant.Plant to Be Replaced in FY84Grab sample
ML18026A83012 January 1984NPDES Noncompliance Notification:On 831221,sewage Treatment Plant Effluent Sample Exceeded Max Permit Limitations. Caused by High Flows Overloading Treatment Capacity of Sys. Sewage Treatment Plant Will Be Replaced in 1984Grab sample
ML18026A83112 January 1984NPDES Noncompliance Notification:On 831223,sample from Condenser Cooling Water Pumping Station Discharge Showed Ph Value of 9.7.Suspected to Be Caused by Loss of Sodium Hydroxide from Tanker Trailer During Unloading
ML18026A84525 January 1984NPDES Noncompliance Notification:On 840110,grab Sample for Sewage Treatment Plant Effluent Exceeded Max Limitation.High Flows Contributed to Noncompliance.Sewage Lagoon Designed to Replace Sewage Treatment Plant.Approval Received 831222Grab sample
ML18026B05214 June 1984NPDES Noncompliance Notification:On 840509 & 30,analyses of Grab Samples Collected Exceeded Max Permit Effluent Limitations.Caused by Sewage Treatment Plant Overload.Sewage Treatment Lagoon Designed to Replace Facility in 1984Grab sample
ML18029A22529 October 1984Corrected Notice of Noncompliance for Aug 1984 Re Sewage Treatment Plant Effluent.Description of Discharge Reported in 840928 Notice Incorrect.Chlorine Contact Tank Pumped Out Periodically to Reduce Overloaded ConditionsGrab sample
ML18032A37416 June 1987NPDES Noncompliance Notification:On 870425,identified Unpermitted Discharge from Mobile Water Treatment Plant Being Operated for TVA by Memphis Mobile.Design Changes Begun for Installation of Permanent Water Treatment Plan
ML18032A5802 September 1987NPDES Noncompliance Notification:On 870804,oil Spill Involving Diesel Fuel & Hydraulic Fluid Entered Tennessee River.Caused by Firefighting activities.Oil-soaked Soil Dug Up & Shipped to Athens,Al landfill.Front-end Loader Removed
ML18033A16424 February 1988NPDES Noncompliance Notification:On 870921,elevation of Wastewater in Sedimentation Pond Dropped 4 Inches W/No Discharge Through Permitted Point.Seepage Point Located in Switchyard Drainage Ditch.Pond Taken Out of Svc for Repairs
ML18033A23013 May 1988Followup to NPDES Noncompliance Notification Re Repair of Sedimentation Pond.Repair Started 871221 & Concluded on 880210.Seepage Observed on 880321 So Pond Not Placed Back in Svc Until Further Repairs Undertaken
ML18033A24616 June 1988NPDES Noncompliance Notification:On 880404,leak of Sodium Nitrite Identified.Less than 25 Lbs Entered Tennessee River. Location of Leak Identified & Chillers Repaired
ML18033A65731 January 1989NPDES Noncompliance Notification: on 890117, Discharge Serial Number 107 for Unit 3 Exceeded the Daily Maximum of 100 Mg/L
ML18094A07211 May 1982NPDES Noncompliance Notification:On 820415,collected Sample Containing 47 Mg/L of BOD5,exceeding Limitation of 45 Mg/L. Caused by Solids Carried Into Chlorine Contact Tank Effluent.Sys Will Be Modified or Replaced
ML20081J2851 November 1983NPDES Noncompliance Notification:On 831012,sewage Treatment Plant Effluent Exceeded Max Limit.Caused by High Flows Washing Solids Over Clarifier Weir Into Chlorine Contact Tank.Plans to Replace Sewage Treatment in FY84 UnderwayGrab sample
ML20083J19023 December 1983NPDES Noncompliance Notification:On 831205,sewage Treatment Plant Effluent Grab Sample Collected on 831129 Exceeded Max Permit Limitations.Caused by Excessive Daily Total Flow. Sewage Lagoon Designed to Replace Sewage Treatment PlantGrab sample
ML20083J38523 December 1983NPDES Noncompliance Notification:On 831013,sewage Treatment Plant Effluent Limit Exceeded Max Limits.Caused by High Flows Washing Out Solids in Chlorine Contact Tank.Sewage Lagoon Will Be Replaced W/Sewage Treatment Plant
ML20093H98418 July 1984NPDES Noncompliance Notification:On 840607,12 & 21,sewage Treatment Plant Effluent Had Excessive Bod & TSS5 Levels. Caused by Plant Overload.Sewage Treatment Lagoon Const Begun.Chlorine Contact Tank Pumped Out PeriodicallyGrab sample
ML20207Q61620 January 1987NPDES Noncompliance Notification:On 870107,sewage Discovered Discharging to Intake Forebay Via Yard Drainage Sys.Caused by Obstructed Sewerline to Old Training Ctr.Blockage Mechanically Dislodged
ML20215C6399 December 1986NPDES Noncompliance Notification:On 861128,further Investigation Revealed That open-ended Pipe Found Discharging Into Canal on 861125 Not Yard Drain But Major Sewer Line Going to Sewage Lagoon.Caused by Settling Fill