Jump to navigation Jump to search
Forwards Repts Re Corrosion Resistence of Boral Matl in Response to Questions on Corrosion of Boral & Stainless Steel in Spent Fuel Storage Pools.Surveillance Programs Re Boral Coupons in Pool Environ Started at Other Facilities
ML20010G691
Person / Time
Site: Clinton  Constellation icon.png
Issue date: 09/14/1981
From: Wuller G
ILLINOIS POWER CO.
To: Turovlin B
Office of Nuclear Reactor Regulation
Shared Package
ML20010G692 List:
References
U-0291, U-291, NUDOCS 8109220414
Download: ML20010G691 (1)


Text

{{#Wiki_filter:_ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Ill/NO!S POWER COMPANY U'0291 L30-81(09-14)-6 4 L[[J 500 SOUTH 27TH STREET, DECATUR, ILLINOl 2525 September 14, 1981 g 3 !?, ',

                                                                                                                                                                          /fr ~     f\

S Mr. Bernard Turovlin  !  % e8 Chemical Engineering Branch I ' Mail Stop P 302 ~s U. S. Nuclear Regulatory Commission D . D/ Washington, D. C. 20553

Dear Mr. Turovlin:

                                                                                                                                                                           @ }ho-In response to your questions on corrosion of fuel racks, please see section 9.1.2.3.2.2 of the Clinton FSAR. Additionally, the enclosed documents discuss the corrosion resistance of Boral material:
1. " Corrosion of Structural and Poison Material in Spent Fuel Storage Pools", presented at the International Corrosion Forum (April 1981) by Brookhaven National Laboratory.
2. B & P Report 577 "The Suitability of Brooks &

Perkins' Spent Fuel Storage Module For Use in BWR Storage Pool", July 21, 1978.

3. B & P Report 554 " Brooks & Perkins, Inc. Spent Fuel Storage Module Corrosion Report", June 1, 1977.
4. Brooks & Perkins,"High Density Fuel Storage Products".
5. Brooks & Perkins, "Boral Neutron Shielding Material",

November, 1975. These documents indicate that corrosion of Boral and stain-less steel is ninimal, and that the performance of structural and poison materi.1 in spent fuel pools has been excellent. Also for your information, a surveillance program will be started in the near future at the Dresden Station (Commonwealth Edison), which will ob=erve Boral coupons in the spent fuel pool environment. A surveillance program on Boral has also been started at the Cooper Station (Nebraska Public Power District). If you have any further questions, please call Mr. Charles Wheeler. g/ 5 Si cere

                                                                                                                                     /               f 8109220414 810914                                                                                                                       G. ,E. Wuller PDR ADOCK 05000461                                                                                                                      Supervisor - Licensing A                                                         PDR                                                                           Nuclear Station Engineering DWW/em                                                                                                                                                                                    !

cc: J. H. Williams, NRC Clinton Project Manager H. H. Livermore, NRC Clinton

                                                                       - _ _ _ _ - - _ _ - _ _ _ _ _ - _ .}}