MONTHYEARML20211H4441999-08-27027 August 1999 Notification of Significant Meeting with Util on 990916 & 17 in Arlington,Tx to Improve Utility & NRC Understanding of Industry & Regulatory Perspectives on Current Issues ML20209G2421999-07-14014 July 1999 Notification of 990722 Meeting with License in Rockville, MD to Discuss Changes in EOI Licensing Organization Including Division of Responsibilities within New EOI Corporate Licensing Group ML20203J5931999-02-17017 February 1999 Notification of Significant Licensee Meeting with Util on 990329 Re NRC Plant Performance Review Summary Meeting ML20203A5081999-02-0505 February 1999 Notification of 980226 Meeting with Texas Utils Electric Co, Southern California Edison & NPPD Re Control of Hazard Barrier Tr, .Agenda Encl ML20195H9221998-11-17017 November 1998 Forwards Exam Repts 50-445/98-301 & 50-446/98-301 Conducted on 980619-26 with as Given Written Exams Encl,Designated for Distribution ML20153B0331998-09-18018 September 1998 Notification of 980929 Meeting with Texas Utilities Electric Co in Rockville,Md to Discuss Licensee Proposed App K Exemption Request & Topical Rept Submitted in Support of Exemption Request ML20236G8291998-07-0202 July 1998 Notification of 980720 Meeting W/Util in CPSES Nuclear Operations Support Facility Lab Annex to Discuss Midloop Operations During Last Refueling Outage ML20236F7611998-06-29029 June 1998 Notification of 980714 Meeting W/Util in Rockville,Md to Discuss Methods of ECCS Analyses & Licensing Submittals Required for Proposing Exemption to Appendix K & Power Uprate License Amend ML20217M9351998-04-0606 April 1998 Notification of Licensee Meeting W/Util on 980407 in Arlington,Tx Re Status of Licensee Actions in Response to GL 96-01 ML20202E6791997-12-0202 December 1997 Notification of 971209 Meeting W/Texas Utilities Electric Co in Rockville,Maryland to Discuss risk-informed Inservice Testing Request for Addl Info Responses, ML20202B1421997-11-26026 November 1997 Notification of 971115 Meeting W/Util in Arlington,Texas to Discuss Recent Unit 2 Refueling/Maint Outage at TU Electric Comanche Peak Plant ML20212G3921997-10-27027 October 1997 Notification of 971112 Meeting W/Util to Discuss Util 970228 Responses to Remaining Three Open Items Listed in NRC Safety Evaluation on Cable Functionality, .Reissued Due to Change of Cc:List ML20203C1181997-10-24024 October 1997 Discusses OI Rept 4-97-027 Re Falsification of Thermolag Matl Insp Records.Allegation Not Substantiated Therefore Enforcement Action Not Appropriate ML20212B7261997-10-16016 October 1997 Notification of 971031 Meeting W/Util in Arlington,Tx Re Predecisional Enforcement Conference ML20206E3401997-09-19019 September 1997 Requests That NRR Conduct Review of Licensee Backfit Claim to Determine of plant-specific Backfit Exists & Submits Recommended Actions to Be Taken If One Does Exists ML20217R1561997-08-28028 August 1997 Informs That GL 96-04 Did Not Require Response for Licensee That Did Not Have Boraflex in Sf Racks ML20237B9901997-07-0303 July 1997 Informs That on 970529-30,NRC Team Attended Severe Accident Mgt Implementation Demonstration at Comanche Peak Steam Electric Station,In Granbury,Tx ML20137C9201997-03-20020 March 1997 Forwards Documentation of Meeting Conducted in Region 4 Office on 970225 to Discuss NRC Enforcement Policy as Applied to Nonescalated Enforcement ML20134N2911996-11-22022 November 1996 Notification of 961205 Meeting W/Util in Arlington,Tx to Discuss Responses to Open Items Listed in NRCs Safety Evaluation on Cable Functionality at Plant, ML20134L9821996-11-19019 November 1996 Notification of Licensee Meeting W/Util on 961204 to Discuss Revision 25 to Emergency Plan ML20128P3011996-10-10010 October 1996 Forwards Analysis of Financial Qualifications & Antitrust Reviews & Input to SER on Proposal to NRC by Tuec for Tx Utilities Corp ML20129E9031996-10-0101 October 1996 Notification of 961002 Meeting W/Util in Rockville,Md Re License Amend Request 96-005,inverters & Battery Chargers Mod ML20135A2801996-04-10010 April 1996 Discusses Director'S Decision Re Actions Requested by Petitioners W/Regard to Use of Thermo-Lag by Reactor Licensees.Petitioners Requested Immediate Shutdown of Reactors Using Thermo-Lag ML20078H7831994-11-0707 November 1994 Forwards Rev 11 to CPSES ODCM & Receipt Acknowledgement Sheet ML20059K5261994-01-21021 January 1994 Notification of 940203 Meeting W/Util in Arlington,Tx to Discuss Realignment of Nuclear Overview Functions ML20059K4921994-01-21021 January 1994 Notification of 940204 Meeting W/Util in Glen Rose,Tx to Discuss Unit 1 Outage Related Activities ML20058C5451993-11-22022 November 1993 Notification of 931202 Enforcement Conference Re Reactor Coolant Spill Inside Containment on 931026 ML20058N1471993-10-0505 October 1993 Notification of 931006 Meeting W/Util in Rockville,Md to Discuss Implementation of Std TSs for Both Units ML20057C9801993-09-27027 September 1993 Discusses 930927 Press Conference Re J O'Connor Announcement That Util Settled Six Rate Matters & Appeals Before Illinois Courts & Commerce Commission by Agreeing to Refund Listed Amount to Customers Over Next 12 Months ML20057A8271993-09-13013 September 1993 Notification of 930920 Meeting W/Util in Rockville,Md to Discuss Fire Barrier Testing & Implementation on Unit 1 ML20056H2941993-09-0101 September 1993 Notification of 930916 Meeting W/Util in Comanche Peak Steam Electric Station to Discuss Safe Shutdown Risk & Other Issues Associated W/Scheduled Oct 1993 Refueling Outage ML20056E4571993-08-0505 August 1993 Forwards Technical Review Rept Re, Tardy Licensee Actions Initiated Because of Delayed Replacement of Batteries in Uninterruptible Power Supplies at Plant ML20128F3531993-02-0202 February 1993 Discusses Emergency Motion to Stay Issuance of low-power Ol.Motion Requested That Commission Issue Order Staying Issuance of Low Power License & Grant Petitioners Chance to Review Withheld Documentation Re Settlement Agreements ML20128D5741993-01-27027 January 1993 Forwards Sworn Joint Affidavit of I Barnes & Ft Grubelich ML20127L9121993-01-26026 January 1993 Forwards NRC Staff Reply to Cfur Request for Publication of Proposed Action Re Licensing of Unit 2.Sworn & Executed Affidavits of I Barnes & Ft Grubelich Will Be Filed as Soon as Possible ML20127H4811993-01-18018 January 1993 Notification of 930121 Meeting W/Util in Rockville,Md to Discuss Fire Protection issues,Thermo-lag Installation Issues & Test Reports ML20127D6951993-01-13013 January 1993 Notification of Significant Licensee Meeting W/Util on on 930122 to Discuss Results of ORAT Insp ML20127C4861993-01-11011 January 1993 Notification of 920115 Public Mgt Meeting W/Util in Region IV Ofc to Discuss CPSES Temporary Mod Program ML20126H3491992-12-29029 December 1992 Notification of Significant Licensee Meeting W/Util on 930107 to Discuss Plant Monthly Status of Const & Licensing Activities ML20126K7681992-12-24024 December 1992 Forwards Part of Earlier Submittal by TU Electric for Distribution as Was Done for Previous Submittal Re ME215 Sapcas Computer Code.Proprietary Abstract Also Encl.Abstract Withheld ML20126F4161992-12-18018 December 1992 Notification of 930107 Meeting W/Util in Rockville,Md to Discuss Design & Operability of Alternate Min Recirculation Path in Highhead Pressure Safety Injection Sys ML20126D9061992-12-14014 December 1992 Notification of 921217 Meeting W/Util in Rockville,Md to Discuss Fire Protection Issues at Plant ML20057C9921992-10-26026 October 1992 Partially Withheld Memo Discussing Rape Allegation at Plant ML20127F5051992-10-21021 October 1992 Discusses 921020 Telcon W/R Feldman of Thermal Science,Inc (TSI) Re 921018 Rept Made by Util That Less than 10 of 2,000 Conduit Sections Provided by TSI Showed Signs of Delamination & Some Had Occluded Porosity in Cross Sections IR 05000445/19920181992-07-0606 July 1992 Discusses Allegation RIV-92-A-0016 Reviewed During Insp Repts 50-445/92-18 & 50-446/92-18 Re Disposal of Radioactive Matl in Landfill Located on Licensee Property ML20057B4601992-05-15015 May 1992 Discusses Telcon W/Rm Dow Re Plant ML20057B1881991-04-18018 April 1991 Discusses 910405 Telcon W/Alleger Re Security Sys at Plant ML20029A4071991-02-13013 February 1991 Forwards Correspondence sign-off Sheet for LER 90-036-01. Suppl Acceptable for Submittal to NRC ML20057B1781991-02-0505 February 1991 Discusses Allegations Made by M Dow Re Scores of Security, Safety Violations & Allegation of Sexual Harassment at Plant ML20065K0251990-11-0707 November 1990 Forwards Amend 2 to Tech Specs,Modifying Tables 2.2-1 & 3.3-3 Re Neutron Flux Meter Setpoints 1999-08-27
[Table view] Category:MEMORANDUMS-CORRESPONDENCE
MONTHYEARML20211H4441999-08-27027 August 1999 Notification of Significant Meeting with Util on 990916 & 17 in Arlington,Tx to Improve Utility & NRC Understanding of Industry & Regulatory Perspectives on Current Issues ML20209G2421999-07-14014 July 1999 Notification of 990722 Meeting with License in Rockville, MD to Discuss Changes in EOI Licensing Organization Including Division of Responsibilities within New EOI Corporate Licensing Group ML20203J5931999-02-17017 February 1999 Notification of Significant Licensee Meeting with Util on 990329 Re NRC Plant Performance Review Summary Meeting ML20203A5081999-02-0505 February 1999 Notification of 980226 Meeting with Texas Utils Electric Co, Southern California Edison & NPPD Re Control of Hazard Barrier Tr, .Agenda Encl ML20195H9221998-11-17017 November 1998 Forwards Exam Repts 50-445/98-301 & 50-446/98-301 Conducted on 980619-26 with as Given Written Exams Encl,Designated for Distribution ML20153B0331998-09-18018 September 1998 Notification of 980929 Meeting with Texas Utilities Electric Co in Rockville,Md to Discuss Licensee Proposed App K Exemption Request & Topical Rept Submitted in Support of Exemption Request ML20236G8291998-07-0202 July 1998 Notification of 980720 Meeting W/Util in CPSES Nuclear Operations Support Facility Lab Annex to Discuss Midloop Operations During Last Refueling Outage ML20236F7611998-06-29029 June 1998 Notification of 980714 Meeting W/Util in Rockville,Md to Discuss Methods of ECCS Analyses & Licensing Submittals Required for Proposing Exemption to Appendix K & Power Uprate License Amend ML20217M9351998-04-0606 April 1998 Notification of Licensee Meeting W/Util on 980407 in Arlington,Tx Re Status of Licensee Actions in Response to GL 96-01 ML20202E6791997-12-0202 December 1997 Notification of 971209 Meeting W/Texas Utilities Electric Co in Rockville,Maryland to Discuss risk-informed Inservice Testing Request for Addl Info Responses, ML20202B1421997-11-26026 November 1997 Notification of 971115 Meeting W/Util in Arlington,Texas to Discuss Recent Unit 2 Refueling/Maint Outage at TU Electric Comanche Peak Plant ML20212G3921997-10-27027 October 1997 Notification of 971112 Meeting W/Util to Discuss Util 970228 Responses to Remaining Three Open Items Listed in NRC Safety Evaluation on Cable Functionality, .Reissued Due to Change of Cc:List ML20203C1181997-10-24024 October 1997 Discusses OI Rept 4-97-027 Re Falsification of Thermolag Matl Insp Records.Allegation Not Substantiated Therefore Enforcement Action Not Appropriate ML20212B7261997-10-16016 October 1997 Notification of 971031 Meeting W/Util in Arlington,Tx Re Predecisional Enforcement Conference ML20206E3401997-09-19019 September 1997 Requests That NRR Conduct Review of Licensee Backfit Claim to Determine of plant-specific Backfit Exists & Submits Recommended Actions to Be Taken If One Does Exists ML20217R1561997-08-28028 August 1997 Informs That GL 96-04 Did Not Require Response for Licensee That Did Not Have Boraflex in Sf Racks ML20237B9901997-07-0303 July 1997 Informs That on 970529-30,NRC Team Attended Severe Accident Mgt Implementation Demonstration at Comanche Peak Steam Electric Station,In Granbury,Tx ML20137C9201997-03-20020 March 1997 Forwards Documentation of Meeting Conducted in Region 4 Office on 970225 to Discuss NRC Enforcement Policy as Applied to Nonescalated Enforcement ML20134N2911996-11-22022 November 1996 Notification of 961205 Meeting W/Util in Arlington,Tx to Discuss Responses to Open Items Listed in NRCs Safety Evaluation on Cable Functionality at Plant, ML20134L9821996-11-19019 November 1996 Notification of Licensee Meeting W/Util on 961204 to Discuss Revision 25 to Emergency Plan ML20128P3011996-10-10010 October 1996 Forwards Analysis of Financial Qualifications & Antitrust Reviews & Input to SER on Proposal to NRC by Tuec for Tx Utilities Corp ML20129E9031996-10-0101 October 1996 Notification of 961002 Meeting W/Util in Rockville,Md Re License Amend Request 96-005,inverters & Battery Chargers Mod ML20135A2801996-04-10010 April 1996 Discusses Director'S Decision Re Actions Requested by Petitioners W/Regard to Use of Thermo-Lag by Reactor Licensees.Petitioners Requested Immediate Shutdown of Reactors Using Thermo-Lag ML20078H7831994-11-0707 November 1994 Forwards Rev 11 to CPSES ODCM & Receipt Acknowledgement Sheet ML20059K4921994-01-21021 January 1994 Notification of 940204 Meeting W/Util in Glen Rose,Tx to Discuss Unit 1 Outage Related Activities ML20059K5261994-01-21021 January 1994 Notification of 940203 Meeting W/Util in Arlington,Tx to Discuss Realignment of Nuclear Overview Functions ML20058C5451993-11-22022 November 1993 Notification of 931202 Enforcement Conference Re Reactor Coolant Spill Inside Containment on 931026 ML20058N1471993-10-0505 October 1993 Notification of 931006 Meeting W/Util in Rockville,Md to Discuss Implementation of Std TSs for Both Units ML20057C9801993-09-27027 September 1993 Discusses 930927 Press Conference Re J O'Connor Announcement That Util Settled Six Rate Matters & Appeals Before Illinois Courts & Commerce Commission by Agreeing to Refund Listed Amount to Customers Over Next 12 Months ML20057A8271993-09-13013 September 1993 Notification of 930920 Meeting W/Util in Rockville,Md to Discuss Fire Barrier Testing & Implementation on Unit 1 ML20056H2941993-09-0101 September 1993 Notification of 930916 Meeting W/Util in Comanche Peak Steam Electric Station to Discuss Safe Shutdown Risk & Other Issues Associated W/Scheduled Oct 1993 Refueling Outage ML20056E4571993-08-0505 August 1993 Forwards Technical Review Rept Re, Tardy Licensee Actions Initiated Because of Delayed Replacement of Batteries in Uninterruptible Power Supplies at Plant ML20128H2931993-02-10010 February 1993 Staff Requirements Memo Re Emergency Motion to Stay Issuance of low-power Operating License.Staff Issued Order Denying Motion ML20128E4301993-02-0505 February 1993 Staff Requirements Memo Re 930129 Affirmation/Discussion & Vote on SECY-93-016 Discussing FRN Concerning Proposed Issuance of OL ML20062J1941993-02-0303 February 1993 Board Notification 93-001:notifies of 930202 Emergency Motion to Stay Issuance of low-power OL Requesting Listed Items Including Issue Order Staying Issuance of License ML20128F3531993-02-0202 February 1993 Discusses Emergency Motion to Stay Issuance of low-power Ol.Motion Requested That Commission Issue Order Staying Issuance of Low Power License & Grant Petitioners Chance to Review Withheld Documentation Re Settlement Agreements ML20128D5741993-01-27027 January 1993 Forwards Sworn Joint Affidavit of I Barnes & Ft Grubelich ML20127L9121993-01-26026 January 1993 Forwards NRC Staff Reply to Cfur Request for Publication of Proposed Action Re Licensing of Unit 2.Sworn & Executed Affidavits of I Barnes & Ft Grubelich Will Be Filed as Soon as Possible ML20127H4811993-01-18018 January 1993 Notification of 930121 Meeting W/Util in Rockville,Md to Discuss Fire Protection issues,Thermo-lag Installation Issues & Test Reports ML20127D6951993-01-13013 January 1993 Notification of Significant Licensee Meeting W/Util on on 930122 to Discuss Results of ORAT Insp ML20127C4861993-01-11011 January 1993 Notification of 920115 Public Mgt Meeting W/Util in Region IV Ofc to Discuss CPSES Temporary Mod Program ML20126H3491992-12-29029 December 1992 Notification of Significant Licensee Meeting W/Util on 930107 to Discuss Plant Monthly Status of Const & Licensing Activities ML20126K7681992-12-24024 December 1992 Forwards Part of Earlier Submittal by TU Electric for Distribution as Was Done for Previous Submittal Re ME215 Sapcas Computer Code.Proprietary Abstract Also Encl.Abstract Withheld ML20126F4161992-12-18018 December 1992 Notification of 930107 Meeting W/Util in Rockville,Md to Discuss Design & Operability of Alternate Min Recirculation Path in Highhead Pressure Safety Injection Sys ML20126D9061992-12-14014 December 1992 Notification of 921217 Meeting W/Util in Rockville,Md to Discuss Fire Protection Issues at Plant ML20057C9921992-10-26026 October 1992 Partially Withheld Memo Discussing Rape Allegation at Plant ML20127F5051992-10-21021 October 1992 Discusses 921020 Telcon W/R Feldman of Thermal Science,Inc (TSI) Re 921018 Rept Made by Util That Less than 10 of 2,000 Conduit Sections Provided by TSI Showed Signs of Delamination & Some Had Occluded Porosity in Cross Sections IR 05000445/19920181992-07-0606 July 1992 Discusses Allegation RIV-92-A-0016 Reviewed During Insp Repts 50-445/92-18 & 50-446/92-18 Re Disposal of Radioactive Matl in Landfill Located on Licensee Property ML20057B4601992-05-15015 May 1992 Discusses Telcon W/Rm Dow Re Plant ML20057B1881991-04-18018 April 1991 Discusses 910405 Telcon W/Alleger Re Security Sys at Plant 1999-08-27
[Table view] |
Text
'
l
/ o
~f UNITED STATES 8 o NUCLEAR REGULATORY COMMISSION
- WASHINGTON, D. C. 20555
-l
%,,,,, SEP 1 I 1985 MEMORANDUM FOR: Vincent S. Noonan, Director Comanche Peak Project FROM: Paul Keshishian Comanche Peak Project '
SUBJECT:
COMANCHE PEAK RESPONSE TEAM VERIFICATION AND CORRECTIVE ACTION ACTIVITIES A review was conducted of the ongoing Comanche Peak Response Team (CPRT) activities during the period of August 26-31, 1985. The principal CPRT .
p__- activities in progress at the present time are those associated with the: .
- 1. - Stone & Webster (SWEC) Design Verification Effort i-
- 2. - Ebasco Design Verification Effort
- 3. - TERA Design Verification Effort
- 4. - 0A/QC Construction Verification Effort
- 5. - TRT Issue Specific Action Plans Implementation
- 1. Stone Webster Design Verification Effort This effort will involve a reanalysis of Unit #1 large bore Class 2 and 3 piping and supports and an evaluation of non-Westinghouse designed supports on Class 1 piping. In addition, for Unit #1, a sample reanalysis of small bore Class 2 and 3 piping will be perfonned. For Unit #2, similar work will be performed for large bore piping and supports.
- however, the reanalysis will include 100% of Class 2 and 3 r, mall bore
~~--
piping. The reanalysis effort tvill be performed utilizing established SWEC methodologies. TERA is conducting the third-party overview of this activity.
- a. Current Activities:
(1) - SWEC is continuing to mobilize manpower for this task at the site and off-site offices and present indications are that the work will be performed at a number of locations. The New York office of SWEC will manage and participate in the effort and design verification work will also be performed at their Houston, Boston, Cherry Hill and Toronto offices.
(2) - SWEC is in the process of completing two key procedures i necessary for their portion of the piping and support l verification work. Comanche Peak Project Procedure (CPPP) #7 -
" Design Criteria for Pipe Stress and Pipe Supports" is expected to be issued by September 3. CPPP #6 " Pipe Stress Analysis 8601220503 e50911 ~
PDR ADOCM 05000445 A PDR
l E . 2' l l
i
[ for As-built ASME Class 2 and 3 Piping Systems" is expected to be issued by September 16.
j l=
l (3) - SWEC har completed a sample walkdown of Unit #1 79-14 program to assess the accuracy of existing as-built documentation previously verified by the project. The walkdown inspection ;
i involved verifying piping and support attributes such as valve j location and orientation, support function and configuration, !
j and orientation and angularity of supports. Preliminary-j indications are that problems were identified with valve :
) orientations and strut / snubber angularities not being in i conformance with design. TUGC0 plans to reverify valve i orientations in the stress packages transmitted to SWEC and i correct the strut / snubber angularities to acceptable tolerances.
(4) - As of August 30. TUGC0 has transmitted 70 large bore stress j
packages of Unit #1 to SWEC for design verification. Each unit '
I will require 302 stress packages for verification. Of the 70 -
I
- stress packages forwarded to SWEC 55 will require reverification. ;
i that the as-built documentation is in conformance with the -
construction as to valve. orientation and strut / snubber j
j ; angularity. All future stress packages will be verified prior ;
- - to transmittal. _;
(5) - Approximately 200 supports on Unit #1 were scheduled to be i modified by TUGC0 prior to the start of the.SWEC effort. This 1 modification work is now on " hold" until a CASE notion-to the ;
j ASLB is ruled on. The CASE position is that the planned 1 j modification would in effect destroy evidence. !
(6) - SWEC is in the process of selecting a Unit #1 small bore l
- piping and support random sample to permit stress analysis. '
i They are now in the process of determining the correct j._
representative population to permit-adequate sample size '
selection.
~
~ '
. (7) - Approximately 30 SWEC engineers presently are at site and it -
! is anticipated that this group will be increased to 50. _The j- present intent _is to perform Unit #2 small bore piping analysis j and support certification and any new support work-or j
! modification required as a result of off-site analysis with the on-site SWEC engineers. All other work presently contemplated
] by SWEC will be performed off-site. .;
! 2. EBASCO Design Verification Effort-f
- This effort involves a complete verification of original design and I as-built construction associated with the design and constructionLof the i Unit #1 and #2 electrical cable tray _and conduit supports. :
5 1
i a. Current Activities: ;
I L
}
j
,-- ._- - . . . _ _ . , - - _ . . . - , _ . , _ . , . . _ , . -,,,,..a_,__,,-,,__-__._ __u,-,_._....-.-
i
. 3 (1) - Ebasco has essentially completed the as-built verification of 2700 cable tray supports for Unit #2. Approximately 2300 of these supports have been design verified. TUGC0 is in the early stages of performing modifications to those supports ~ requiring changes.
(2) - In the comon area of 1200 cable tray supports for Unit #2, 750 have been as-built and 320 design verified.
(3) - In Unit #1 and those cable tray supports in the comon area serving Unit #1, of 4527 supports approximately 600 have been as-built. Of these 600, some 473 have been transmitted to Ebasco for design verification.
(4) - At the present time there are six teams of inspectors walking down Unit f1 cable tray supports to document the as-built condition. These teams consist of three men each and it is comtemplated to increase the number of teams to approximately 25
_ to expedite the as-built process. -
(5) - Corporate Consulting and Development (CCL) was on site the -
. week of August 26 for the static load testing of Unistruts for t determining their acceptability for against the wall service.
The purpose of this testing program is to demonstrate that the Unistrut supports used in the Seismic Category I conduit and junction box supports are structurally adequate to withstand the maximum loads postulated to be applied to the supports during the design earthquake conditions. TUGC0 anticipates receiving the CCL test report the latter part of September.
(6) - On Unit #1 conduit supports, Ebasco is presently determining the total population. It is planned to select a statistically based sample of conduit supports and then perform as-built.
~
(7) - On Unit #1, of the total population of approximately 32,000 conduit supports there are approximately 7200 of Unistrut design.
CYGNA Energy Services has raised questions about the adequacy of these Unistrut supports. Of the 7200 supports 6000 of these are against the wall supports which TUGC0 believes they will be able to demonstrate that they are qualified. TUGC0 believes at the present time that of the remaining 1200 some 700 will need to be replaced and CCL will conduct tests to determine the adequacy of the balance.
- 3. TERA Design Verification Effort TERA is responsible for the Design Adequacy Plan, acts as third party over reviewer for design review, resolution of TRT issue specific action plans for the mechanical, civil and structural areas, tracking all external issues and will prepare and issue a final design adequacy report at the conclusion of their effort.
I 4
- a. Current Activities (1) - TERA is in the process of reviewing all relevant documentation in order 'to prepare a matrix and tracking system for all external issues originating from Walsh/Doyle, SRT, SIT, CAT, ASLB, SSER, applicant and intervenors. This matrix will be included in the program plan and will identify the issue, the source and where in the Program Plan it is addressed.
(2) - TERA is in the process of preparing Design Adequacy Procedures (DAP) for implementation of their review process. Of the 19 CPRT -DAP procedures required, 4 have been released for interim use and the balance are scheduled to be released for use by the end of September.
(3) - TERA's site force of a manager and 6 issue coordinators are performing their respective activities relative to the TRT Issue Specific Action Plans that they are participating in.
,~
~
(4) - TERA has received the NRC's staff programatic coments to the' CPRT Program Plan and has presented their suggested revisions to'
- the CPRT Senior Review Team.
(5) - TERA is continuing with their Phase 3 effort of their Design Adequacy Plan. The Phase 3 effort involves the performance of validation checks to confirm that the design review areas selected can be utilized as representative of the total plant design. They are now in the process of preparing a schedule for completion of this activity.
(6) - They are currently reviewing detailed equipment lists to identify those vendors that are unique to determine that proper hardware has been delivered to the site in accordance with FSAR comittments and procurement specifications.
- (7) - TERA is preparing review procedures and inspection check lists
. to implement their design verification activities for the Auxiliary Feedwater System and the Electric Power System.
(8) - TERA has received the Gibbs and Hill redesign of the control room ceiling and is in the process of reviewing them.
(9) - During the week of Sept. 9, 30 TERA personnel will receive training in the implementation of DAP procedures. One session will be held at Berkley, California and one at Bethesda, Maryland.
(10) - The TERA organization has added a DAP quality assurance auditor and a QA/QC project quality assurance engineer to see that the TERA QA/QC comitments are properly implemented.
- 4. QA/QC Construction Verification Effort
1 5
This effort encompasses a statistically based sample reinspection of QC accepted construction work supplemental by a review of related quality documentation.
- a. Current Activities :
(1) - The procedures that describe administrative controls for this effort are essentially complete. Of 20 required procedures 19 have been completed.
(2) - Inspection procedures and checklists are continuing to be prepared. About 50% of these procedures have been completed and issued for use.
(3) - A total of 26 hardware population descriptions have been completed which essentially completes this effort.
(4) - The internal QA program relative to the construction reinspection effort has been prepared and is presently being implemented. .
(5) - To date of the 26 hardware population inspections none have 1 been completed though a number are partially completed.
~
(6) - As of the date of this inspection the review of related document packages has not as yet been initiated.
(7) - For the present scope of work, it is estimated that approximately 2500 hardware reinspection packages had been released for use and approximately 220 packages had actually been field inspected. These completed field inspection packages are now in the review process.
(8) - For the approximate 220 reinspection packages implemented 136 deviation reports were generated. Of the 44 deviation reports evaluated to date, 35 were detennined to be valid. The safety significance of the valid deviation reports is now being determined.
(9) - At the time of the inspection it is estimated that about 2-3%
of the reinspection effort has been completed. Currently this effort is 3-4 weeks behind schedule primarily because of longer than estimated times to prepare inspection procedures, checklists and establish hardware populations.
(10) - At present the manpower for this effort is 149 individuals.
It is expected to peak at approximately 175 at the end of this year. Of this total about 40 individuals will be involved in determining the safety significance of the deviation reports originating from the inspections.
(11) - As part of this effort these are approximately 2650 documentation review packages to be prepared and issued for reinspection. At the' time of this inspection 119 had been issued but none of the packages had been reviewed.
6 (12) -'RIV is closely following this reinspection effort and presently plans to witness 10% of the reinspections and independently inspect 5%. On August 29, RIV had a meeting with the Applicant at the site to indicate some of the concerns they have with the reinspection effort.
- 5. TRT Issue Specific Action Plans-Implementation Each of the SSER's prepared as a result of the TRT inspections resulted in specific actions required by TUEC to resolve outstanding deficiencies. ,
For each of the-issue specific items TUEC has developed action plans and is in the process of implementing them. As of each of the action plans is completed a results report will be prepared for each item. The specific details for each of the following TRT issue specific items can be found in - ;
the respective SSERs or in the Program Plan under Appendix C. ;
- a. Current Activities:
The following is a listing of the TRT items and their status at the time
,_- of the site review: }
~~
ITEM STATUS
. Heat Shrinkable . Action cor.pleted. ,
Insulation Sleeves Preparing results report. '
. Inspection Reports on . Actions cumpleted.. !
Butt Splices Results report in review !
review cycle.
. Butt Splice Qualification . Actions completed. .
Results report in review cycle. -
. . Agreement Between DWGS . Actions completed.
and Field Tenn's Revising results report.
. NCRs on Vendor Installed . Work completed.- !
Amp. Tenninal Plugs Revising results report. ,
. Flexible Conduit To . Additional analysis in ,
Flex. Conduit Separation progress. l
. Flex. Conduit to Cable . Additional analysis in Separation progress
. Conduit to Cable Tray . Actions completed.
Separation Results report in review cycle.
. Barrier Removal . Actions completed. t Revising results report.
E h
7 Item STATUS
. Electrical Conduit . Analysis in progress and Supports expect to start walkdown by mid-September
. QC Inspector Qual's . Electrical Inspector l Qualifications Review t Completed. .
I Review of ASME inspector qualifications in progress.
. Guidelines for Admin. . Review completed.
Of QC Inspection Test Preparing results report.
. Reinforcing Steel In . Work Completed.
Results report in review The Reactor Cavity cycle. ,
. Cancrete Compression . Field work completed. _.
Strength Preparing results report.
. Maint. of Air Gap . Mapping of air gaps Between Concrete is complete. Evaluating bids Buildings for removal of concrete and debris.
l . Seismic Design of . Gibbs & Hill design of l Control Room Ceiling new ceiling complete. TERA j Elements reviewing design.
- . Rebar in the Fuel . Evaluation Complete.
Handling Building Results report in j - review process.
. Hot Functional (HFT) . Review completed.
Data Packages Preparing results report.
. . JTG Approval of Test . Work complete. Results l Data report in review cycle.
. Technical Specification . Work complete. Results For Deferred Tests report in review cycle.
. Traceability of Test . Work complete. Results
- Equipment report in review cycle.
l . Conduct of CILRT . Work Complete. Preparing l results report.
i l
l l
. 8 Item Status
. Prerequisite Testing . Evaluation complete.
Preparing results report.
. Preoperational Testing . Review completed.
Preparing results report.
. Skewed Welds in NF . Sample inspected.
Supports Engineers evaluating results.
. Steam Generator . Work on " Hold". Awaiting Anchor Bolts completion of evaluation of upper lateral support t by Gibbs and Hill.
. Design Consideration . Reanalysis completed.
For Piping Systems Bet. Preparing results
. Seis CAT I & Non-Seismic report. .
] Cat I Bldgs. -
. . Plug Welds . Inspection in Progress
. Installation of Main . All field work complete.
Steam Pipes Preparing results report.
. Gap Between Reactor . Design change and critical Vessel Insulation & space review in progress.
Biological Shield Wall Preparing sample population list.
. Polar Crane Shiming . Crane test procedure being reviewed. Receiving test
- equipment hardware for mid-C October crane test.
~
. Valve Disassembly . Valve inspections in .
1 progress.
! . Non-Conformance and . Reviewed current procedures.
Corrective Action Systems Review of NCR populations in Progress.
ff '