LER 80-021/03L-0:on 800630,during Weekly Environ Air Sample Collections,Incomplete Samples Collected at Three Stations. Caused by Failed Pumps Due to Damaged Bearings.New Pumps Installed.Pump & Ventilation Mods Being Evaluated
ML19330B671
Person / Time
Site: Vermont Yankee Entergy icon.png
Issue date: 07/31/1980
From: Murphy W
VERMONT YANKEE NUCLEAR POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19330B667 List:
References
LER-80-021-03L, LER-80-21-3L, NUDOCS 8008050355
Download: ML19330B671 (2)


Text

C LER 80-21/3L

- c . LICENSEE EVENT REPORT

( y CONTROL CLOCK: l l l l l l l (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6 lo l1l8 9l V l LICENSEE 7

T l VCODE lY l S l 1 l@! 0 l0 l- LICENSE 14 15 l0 l0 NyVBER l0 l0 l0 l- l0 l0 25 l@l4 26 IlLICENSE l1 l1TYPE l1JOl@l$7 CATl 58 l@

CON'T IOI11 3fn"c'60l L l@l 0 l 5DOCKET l 0 lNUVBER 0 l 0 12 17 l1 l@lEVENT0 16 7 8 61 68 6? DATE13 l0 18 10 l@l0 74 75 REPORT DATE17 l1 Il80 IR ln l@

EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h 1012l l Diaring weekly Environcental Air Samole collections nn 6-10 nnd 7-7 4e une afeenuavaa I

[Ol31lthat incomplete samples were collected at three stations. Technical Sneciffencinna l l0l4l l Table 3.9.1 requires that continuous air sampling be performed. Low plant release l l0ist l levels were monitored during this period and past experience has indicated that these l l 0 l6 l l levels are undetectable by environmental air sampling. There are no previous similar l l

lO17] l occurrences.

I O l8 l l DE CODE S BC E COMPONENT CODE SUSC DE S DE

[ TIT l lB lB l@ yh l Blh l P l U l M l P l X l X lh lH l@ d @ 18 19 20 7 8 9 10 11 12 13 SEQUENTIAL OCCUR R E NCE REPORT REVISION

_ EVENT YE AR REPORT NO. CODE TYPE N O.

b "LERyUgRO E

l-l l0l2lll l/l 10 l 3 l l Ll l-l 10 l

_ l218l0l 22 23 24 26 27 28 29 30 31 32 AK N ACTC O PL NT ME HOURS SB IT FORAb B. SUPPLI MANUF CTURER l33C lgl34C l@ l35 Z ]g W@ l 0l 0l 0l 0l lY l@

36 37 40 di l42N l@ lLl@ lXl9l9l9l@

43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h l i l 0 l l Failed pumps caused the lapse in sampling and bearings were found to be damaced in thel 11 111 I affected pumps. New or reconditioned pumps were installed in the starinne. I

,, ,,,; Modifications of the pump and ventilation are being evaluated. I l

11 131 l I

11 141 l 7 8 9 80 ST S  % POWER OTHER STATUS I O Y OfSCOVERY DESCRIPTION NA  !

l1 l 5 l l El@ l 0 l 9 l 9 lhl l l B lhl Technician Observation A TlVITY CO TENT r.ELEASED OF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE l116 l y @ l Z l@l NA 44 l l 45 NA 80 7 8 9 10 11 PERSONNEL FXPOSURES NUMBER TYPE DESCRIPTION l 1 l 7 l l 0] 0l 0lhl Zl@l NA l PERSONN E L INJU IES NUMBER OESCRIPTION fiTTl8 9l 0l Ol 0lhl 7 11 12 NA 80 l

LOSS OF OR DAMAGE TO FACILITY TYPE DESCRIPTION 7

1 9 8 9 d h! 10 NA 80 l

PUBLICITY

, g iS o ESCRIPTION 8008050 35 ,

68 69

,,,,,, ,,,,,,,g NRC USE ONLY 80 1; 7 8 9 :10 O

NAME OF PREPARER

( -

4. :r w

VTVYS1 05000271 LER 80-21/3L EVENT DESCRIPTION.AND PROBABLE CONSEQUENCES During 'the weekly servicing and sample collection of the air monitoring stations associated with the Radiological Environmental Monitoring Program, it was-discovered on June 30, 1980 that the sampling pump was malfunctioning and incomplete air particulates and radioidine samples were collected at Station .

AT 2.3 -(Northfield). . Station AT 2.3 collected 568.6 cubic feet before the pump failed. Additionally, it was discovered on July 7, 1980 that the sampling pumps were malfunctioning and incomplete air particulates and radioiodine .

samples .were collected at Stations AT 1.2 (Hinsdale Depot), AT 1.1 (North Hinsdale) and AT 2.3 (Northfield) during the preceding week from June 30, 1980 to July 7, 1980.' '(Station AT 1.1 collected 1031 cubic feet, Station AT 1.2 collected 3578 cubic feet and Station AT 2.3 collected 1144 nubic feet before the pumps at these stations failed. Total volume for these ste; ions averages approximately 6800 cubic feet per week during normal operation of the systems.

Technical Specifications Table 3.9.1 requires that continuous air sampling be '

performed.

. Although the plantwas operating at 99% power during this period, vent

. stack effluent monitoring indicated normal, low release rates of less than 100 uci/sec noble gas and an average 2.07 x 10-4 uci/see 1-131. Since past experience has demonstrated that these release levels are undetectable by environmental air sampling, it was concluded that there were no consequences, or potential consequences, to the health and safety of the public.

CAUSE DESCRIPTION AND CORRECTIVE ACTION Further inspection of the vacuum pumps used in these stations revealed failed  ;

pump bearings in all three pumps. Excessive heat buildup in the pump housing

. caused by unseasonably high atomspheric temperatures in the preceding week could be a cause of bearing failure in the pumps. New or reconditioned pumps were

installed in these stations. Modifications of the pump and ventilation are being evaluated.

)

l t

e

- . - - - - - - - - - , , . , - - . - . - . - - , , -,