{{#Wiki_filter:rch 13, 2009
{{#Wiki_filter:UNITED STATES NU C LE AR RE G UL AT O RY C O M M I S S I O N rch 13, 2009


==SUBJECT:==
==SUBJECT:==
Line 26: Line 26:
On December 31, 2008, the Nuclear Regulatory Commission (NRC) staff completed its annual inspection of the Emergency Preparedness Program at the Grand Gulf Nuclear Station.
On December 31, 2008, the Nuclear Regulatory Commission (NRC) staff completed its annual inspection of the Emergency Preparedness Program at the Grand Gulf Nuclear Station.


This inspection began on January 1, 2008. Issuance of this letter closes NRC Inspection  
This inspection began on January 1, 2008. Issuance of this letter closes NRC Inspection Report 05000416/2008501. Observations and findings in these areas were provided in the quarterly integrated reports for your site.


Report 05000416/2008501. Observations and findings in these areas were provided in the
In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
 
quarterly integrated reports for your site.
 
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be  
 
available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) com ponent of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).


Sincerely,
Sincerely,
/RA/
/RA/
Michael P. Shannon, Chief Plant Support Branch-1 Division of Reactor Safety  
Michael P. Shannon, Chief Plant Support Branch-1 Division of Reactor Safety Docket: 50-416 License: NPF-29


Docket: 50-416
Entergy Operations, Inc.  -2-cc:
Senior Vice President Entergy Nuclear Operations P. O. Box 31995 Jackson, MS 39286-1995 Senior Vice President and COO Entergy Operations, Inc.


License: NPF-29 UNITED STATESNUCLEAR REGULATORY COMMISSIONREGION IV612 EAST LAMAR BLVD, SUITE 400ARLINGTON, TEXAS 76011-4125 Entergy Operations, Inc. - 2 -
P. O. Box 31995 Jackson, MS 39286-1995 Vice President, Oversight Entergy Services, Inc.


cc:
P. O. Box 31995 Jackson, MS 39286-1995 Chief, Energy and Transportation Branch Environmental Compliance and Enforcement Division Mississippi Department of Environmental Quality P. O. Box 10385 Jackson, MS 39289-0385 President Claiborne County Board of Supervisors 510 Market Street Port Gibson, MS 39150 Senior Manager Nuclear Safety & Licensing Entergy Nuclear Operations P. O. Box 31995 Jackson, MS 39286-1995 Manager, Licensing Entergy Operations, Inc.
Senior Vice President


Entergy Nuclear Operations
Grand Gulf Nuclear Station P. O. Box 756 Port Gibson, MS 39150 Attorney General Department of Justice State of Louisiana P. O. Box 94005 Baton Rouge, LA 70804-9005


P. O. Box 31995  
Entergy Operations, Inc.  -3-Office of the Governor State of Mississippi P. O. Box 139 Jackson, MS 39201 Attorney General Assistant Attorney General State of Mississippi P. O. Box 220 Jackson, MS 39205 State Health Officer State Health Board P. O. Box 1700 Jackson, MS 39215 Associate General Counsel Entergy Nuclear Operations P. O. Box 31995 Jackson, MS 39286-1995 Louisiana Dept. of Environmental Qualityl Radiological Emergency Planning and Response Division P. O. Box 4312 Baton Rouge, LA 70821-4312


Jackson, MS 39286-1995
Entergy Operations, Inc. -4-Electronic distribution by RIV:
 
Regional Administrator (Elmo.Collins@nrc.gov)
Senior Vice President and COO
Deputy Regional Administrator (Chuck.Casto@nrc.gov)
 
DRP Director (Dwight.Chamberlain@nrc.gov)
Entergy Operations, Inc.
DRP Deputy Director (Anton.Vegel@nrc.gov)
 
DRS Director (Roy.Caniano@nrc.gov)
P. O. Box 31995
DRS Deputy Director (Troy.Pruett@nrc.gov)
 
Senior Resident Inspector Rich.Smith@nrc.gov)
Jackson, MS 39286-1995
Resident Inspector (Andy.Barrett@nrc.gov)
 
Branch Chief, DRP/C (Geoffrey.Miller@nrc.gov)
Vice President, Oversight
Senior Project Engineer, DRP/C (Wayne.Walker@nrc.gov)
 
GG Site Secretary (Nancy.Spivey@nrc.gov)
Entergy Services, Inc.
Team Leader, DRP/TSS (Chuck.Paulk@nrc.gov)
 
RITS Coordinator (Marisa.Herrera@nrc.gov)
P. O. Box 31995
RidsNsirDso@nrc.gov SUNSI Review Completed: ___Y___ ADAMS: 6 Yes No Initials: __lmb____
 
6 Publicly Available Non-Publicly Available Sensitive 6 Non-Sensitive C:PSB1 MPShannon
Jackson, MS 39286-1995
/RA/
 
3/13/09 OFFICIAL RECORD COPY   T=Telephone E=E-mail F=Fax
Chief, Energy and Transportation Branch
 
Environmental Compliance and
 
Enforcement Division
 
Mississippi Department of
 
Environmental Quality
 
P. O. Box 10385
 
Jackson, MS 39289-0385
 
President
 
Claiborne County
 
Board of Supervisors
 
510 Market Street
 
Port Gibson, MS 39150
 
Senior Manager
 
Nuclear Safety & Licensing
 
Entergy Nuclear Operations
 
P. O. Box 31995
 
Jackson, MS 39286-1995
 
Manager, Licensing
 
Entergy Operations, Inc.
 
Grand Gulf Nuclear Station
 
P. O. Box 756
 
Port Gibson, MS 39150
 
Attorney General
 
Department of Justice
 
State of Louisiana
 
P. O. Box 94005
 
Baton Rouge, LA 70804-9005 Entergy Operations, Inc. - 3 -
 
Office of the Governor
 
State of Mississippi
 
P. O. Box 139
 
Jackson, MS 39201
 
Attorney General
 
Assistant Attorney General
 
State of Mississippi
 
P. O. Box 220
 
Jackson, MS 39205
 
State Health Officer
 
State Health Board
 
P. O. Box 1700
 
Jackson, MS 39215
 
Associate General Counsel
 
Entergy Nuclear Operations
 
P. O. Box 31995
 
Jackson, MS 39286-1995
 
Louisiana Dept. of Environmental Qualityl
 
Radiological Emergency Planning and
 
Response Division
 
P. O. Box 4312
 
Baton Rouge, LA 70821-4312 Entergy Operations, Inc. - 4 -  
 
Electronic distribution by RIV:  
 
Regional Administrator (Elmo.Collins@nrc.gov) Deputy Regional Administrator (Chuck.Casto@nrc.gov) DRP Director (Dwight.Chamberlain@nrc.gov) DRP Deputy Director (Anton.Vegel@nrc.gov) DRS Director (Roy.Caniano@nrc.gov) DRS Deputy Director (Troy.Pruett@nrc.gov) Senior Resident Inspector Rich.Smith@nrc.gov) Resident Inspector (Andy.Barrett@nrc.gov) Branch Chief, DRP/C (Geoffrey.Miller@nrc.gov) Senior Project Engineer, DRP/C (Wayne.Walker@nrc.gov) GG Site Secretary (Nancy.Spivey@nrc.gov) Team Leader, DRP/TSS (Chuck.Paulk@nrc.gov) RITS Coordinator (Marisa.Herrera@nrc.gov) RidsNsirDso@nrc.gov
 
SUNSI Review Completed: ___Y___ ADAMS: Yes No Initials: __lmb____ Publicly Available Non-Publicly Available Sensitive Non-Sensitive C:PSB1 MPShannon /RA/ 3/13/09 OFFICIAL RECORD COPY T=Telephone E=E-mail F=Fax
}}
}}

Latest revision as of 09:07, 14 November 2019

IR 05000416-20-08-501 on 12/31/2008 for Grand Gulf Nuclear Station - NRC Emergency Preparedness Annual Inspection Report
ML090721125
Person / Time
Site: Grand Gulf Entergy icon.png
Issue date: 03/13/2009
From: Shannon M
Division of Reactor Safety IV
To: Douet J
Entergy Operations
References
IR-08-501
Download: ML090721125 (4)


Text

UNITED STATES NU C LE AR RE G UL AT O RY C O M M I S S I O N rch 13, 2009

SUBJECT:

GRAND GULF NUCLEAR STATION - NRC EMERGENCY PREPAREDNESS ANNUAL INSPECTION REPORT 05000416/2008501

Dear Mr. Douet:

On December 31, 2008, the Nuclear Regulatory Commission (NRC) staff completed its annual inspection of the Emergency Preparedness Program at the Grand Gulf Nuclear Station.

This inspection began on January 1, 2008. Issuance of this letter closes NRC Inspection Report 05000416/2008501. Observations and findings in these areas were provided in the quarterly integrated reports for your site.

In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Sincerely,

/RA/

Michael P. Shannon, Chief Plant Support Branch-1 Division of Reactor Safety Docket: 50-416 License: NPF-29

Entergy Operations, Inc. -2-cc:

Senior Vice President Entergy Nuclear Operations P. O. Box 31995 Jackson, MS 39286-1995 Senior Vice President and COO Entergy Operations, Inc.

P. O. Box 31995 Jackson, MS 39286-1995 Vice President, Oversight Entergy Services, Inc.

P. O. Box 31995 Jackson, MS 39286-1995 Chief, Energy and Transportation Branch Environmental Compliance and Enforcement Division Mississippi Department of Environmental Quality P. O. Box 10385 Jackson, MS 39289-0385 President Claiborne County Board of Supervisors 510 Market Street Port Gibson, MS 39150 Senior Manager Nuclear Safety & Licensing Entergy Nuclear Operations P. O. Box 31995 Jackson, MS 39286-1995 Manager, Licensing Entergy Operations, Inc.

Grand Gulf Nuclear Station P. O. Box 756 Port Gibson, MS 39150 Attorney General Department of Justice State of Louisiana P. O. Box 94005 Baton Rouge, LA 70804-9005

Entergy Operations, Inc. -3-Office of the Governor State of Mississippi P. O. Box 139 Jackson, MS 39201 Attorney General Assistant Attorney General State of Mississippi P. O. Box 220 Jackson, MS 39205 State Health Officer State Health Board P. O. Box 1700 Jackson, MS 39215 Associate General Counsel Entergy Nuclear Operations P. O. Box 31995 Jackson, MS 39286-1995 Louisiana Dept. of Environmental Qualityl Radiological Emergency Planning and Response Division P. O. Box 4312 Baton Rouge, LA 70821-4312

Entergy Operations, Inc. -4-Electronic distribution by RIV:

Regional Administrator (Elmo.Collins@nrc.gov)

Deputy Regional Administrator (Chuck.Casto@nrc.gov)

DRP Director (Dwight.Chamberlain@nrc.gov)

DRP Deputy Director (Anton.Vegel@nrc.gov)

DRS Director (Roy.Caniano@nrc.gov)

DRS Deputy Director (Troy.Pruett@nrc.gov)

Senior Resident Inspector Rich.Smith@nrc.gov)

Resident Inspector (Andy.Barrett@nrc.gov)

Branch Chief, DRP/C (Geoffrey.Miller@nrc.gov)

Senior Project Engineer, DRP/C (Wayne.Walker@nrc.gov)

GG Site Secretary (Nancy.Spivey@nrc.gov)

Team Leader, DRP/TSS (Chuck.Paulk@nrc.gov)

RITS Coordinator (Marisa.Herrera@nrc.gov)

RidsNsirDso@nrc.gov SUNSI Review Completed: ___Y___ ADAMS: 6 Yes No Initials: __lmb____

6 Publicly Available Non-Publicly Available Sensitive 6 Non-Sensitive C:PSB1 MPShannon

/RA/

3/13/09 OFFICIAL RECORD COPY T=Telephone E=E-mail F=Fax