Line 3: Line 3:
| issue date = 01/08/2008
| issue date = 01/08/2008
| title = Response to Request for Additional Information (RAI) Regarding Unit 2 Technical Specification Change 06-06, Probability of Prior Cycle Detection (Popcd)
| title = Response to Request for Additional Information (RAI) Regarding Unit 2 Technical Specification Change 06-06, Probability of Prior Cycle Detection (Popcd)
| author name = Smith J D
| author name = Smith J
| author affiliation = Tennessee Valley Authority
| author affiliation = Tennessee Valley Authority
| addressee name =  
| addressee name =  
Line 18: Line 18:


=Text=
=Text=
{{#Wiki_filter:January 8, 2008   10 CFR 50.90 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk  
{{#Wiki_filter:January 8, 2008 10 CFR 50.90 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Gentlemen:
 
In the Matter of                   )       Docket No. 50-328 Tennessee Valley Authority         )
Washington, D.C. 20555 Gentlemen:
SEQUOYAH NUCLEAR PLANT (SQN) RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION (RAI) REGARDING UNIT 2 TECHNICAL SPECIFICATION CHANGE 06-06, PROBABILITY OF PRIOR CYCLE DETECTION (POPCD) (TAC NO. MD4110)
In the Matter of                 )     Docket No. 50-328 Tennessee Valley Authority   )
SEQUOYAH NUCLEAR PLANT (SQN) RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION (RAI) REGARDING UNIT 2 TECHNICAL  
 
SPECIFICATION CHANGE 06-06, PROBABILITY OF PRIOR CYCLE  
 
DETECTION (POPCD) (TAC NO. MD4110)  


==Reference:==
==Reference:==
NRC letter to TVA dated November 20, 2007, Sequoyah Nuclear Plant, Unit 2 - Request for  
NRC letter to TVA dated November 20, 2007, Sequoyah Nuclear Plant, Unit 2 - Request for Additional Information Regarding Revised Probability of Prior Cycle Detection Model (TAC No. MD4110)
Enclosed are the TVA responses to the staffs request for additional information from the reference letter. TVAs responses were discussed with your staff during telephone conference calls on November 27 and December 18, 2007. TVAs responses support staff review of the subject TS change for SQN Unit 2. provides the TVA responses to the staffs questions. Enclosure 2 provides reformatted TS pages for TS Change 06-06 that support TVAs response to NRC question No. 1. Please note that the TS pages provided by Enclosure 2 supersede the TS pages previously provided by TVAs January 12, 2007 letter. Enclosure 3 provides a TVA commitment associated with implementation of the subject TS change.


Additional Information Regarding Revised
U.S. Nuclear Regulatory Commission Page 2 January 8, 2008 Please direct questions concerning this issue to J. D. Smith at (423) 843-7170.
I declare under penalty of perjury that the foregoing is true and correct. Executed on this - 8th day of January, 2008.
Sincerely, n Manager, Site Licensing and Industry Affairs Enclosures
: 1. TVA Reponses to NRC's Request for Additional Information
: 2. Reformatted TS and Bases page markups for TSC 06-06
: 3. TVA Commitment cc (Enclosures):
Mr. Brendan T. Moroney, Project Manager U.S. Nuclear Regulatory Commission Mail Stop 08G-9a One White Flint North 11555 Rockville Pike Rockville, Maryland 20852-2739 Mr. Lawrence E. Nanney, Director Division of Radiological Health Third Floor L&C Annex 401 Church Street Nashville, Tennessee 37243-1532


Probability of Prior Cycle Detection Model (TAC
ENCLOSURE 1 TENNESSEE VALLEY AUTHORITY (TVA)
 
No. MD4110)
Enclosed are the TVA responses to the staffs request for additional information from the reference letter. TVAs
 
responses were discussed with your staff during telephone
 
conference calls on November 27 and December 18, 2007. TVAs
 
responses support staff review of the subject TS change for
 
SQN Unit 2. provides the TVA responses to the staffs questions. Enclosure 2 provides reformatted TS pages for TS
 
Change 06-06 that support TVAs response to NRC question
 
No. 1. Please note that the TS pages provided by Enclosure 2
 
supersede the TS pages previously provided by TVAs January
 
12, 2007 letter. Enclosure 3 provides a TVA commitment
 
associated with implementation of the subject TS change.
U.S. Nuclear Regulatory Commission Page 2 January 8, 2008 Please direct questions concerning this issue to J. D. Smith at (423) 843-7170.
I declare under penalty of perjury that the foregoing is true and correct. Executed on this 8th day of January, 2008. - Sincerely, n Manager, Site Licensing and Industry Affairs Enclosures
: 1. TVA Reponses to NRC's Request for Additional Information
: 2. Reformatted TS and Bases page markups for TSC 06-06 3. TVA Commitment cc (Enclosures)
: Mr. Brendan T. Moroney, Project Manager U.S. Nuclear Regulatory Commission Mail Stop 08G-9a One White Flint North 11555 Rockville Pike Rockville, Maryland 20852-2739 Mr. Lawrence E. Nanney, Director Division of Radiological Health Third Floor L&C Annex 401 Church Street Nashville, Tennessee 37243-1532 E1-1 ENCLOSURE 1 TENNESSEE VALLEY AUTHORITY (TVA)
SEQUOYAH NUCLEAR PLANT (SQN)
SEQUOYAH NUCLEAR PLANT (SQN)
UNIT 2 RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION (RAI) FOR SQN TECHNICAL SPECIFICATION (TS) CHANGE 06-06, PROBABILITY OF PRIOR CYCLE DETECTION (POPCD)
UNIT 2 RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION (RAI) FOR SQN TECHNICAL SPECIFICATION (TS) CHANGE 06-06, PROBABILITY OF PRIOR CYCLE DETECTION (POPCD)
NRC Question 1 Regarding your proposed reporting requirements for implementation of the POPCD methodology, please update your proposal to reflect  
NRC Question 1 Regarding your proposed reporting requirements for implementation of the POPCD methodology, please update your proposal to reflect your new SG technical specification format. In addition, please discuss your plans to clarify when the report would be submitted since as currently written, you would be required to submit a report 90-days after the SGs were returned to service regardless of whether SG tube inspections were performed. For example, you could specify that consistent with Technical Specification 6.9.1.16.1 the report would be submitted 90-days after the initial entry into MODE 4 following completion of an inspection performed in accordance with Specification 6.8.4.k, Steam Generator (SG) Program.
 
Please note that the discussion in Section 2.0 of Enclosure 1 to your January 12, 2007, submittal does not match the wording in your proposed Technical Specifications in Enclosure 2. The staff assumed that the proposed wording in the Technical Specifications is what you intended to propose.
your new SG technical specification format. In addition, please  
TVA response  of this submittal provides reformatted TS and Bases markup pages that supersede the markups previously provided in TVAs January 12, 2007 submittal. It may be noted that the wording in Section 2.0 of TVAs January 12, 2007, submittal did contain typographical errors that resulted in a mismatch with the wording provided in Enclosure 2. The proposed TS wording provided in Enclosure 2 was the intended wording.
 
NRC Question 2 Regarding the changes you intend to make to your Bases, the NRC does not have a copy of the Westinghouse letter that is referenced. As a result, it can not comment on whether this change is appropriate. The NRC expects that if the POPCD methodology is approved that it would be implemented consistent E1-1
discuss your plans to clarify when the report would be submitted  


since as currently written, you would be required to submit a  
with the methodology provided to the staff to support its approval. The methodology in the referenced Westinghouse letter may have been modified as a result of responses to the NRC staffs request for additional information. Please discuss your plans to ensure that the Bases reflect the actual POPCD methodology that is approved by the NRC staff.
TVA Response TVA has revised the Bases pages to reflect the actual POPCD methodology approved by the NRC staff. (Note: Enclosure 2 of this submittal contains the Bases page markups with the references that include the NRC letter that approves the POPCD methodology for SQN Unit 2.)
NRC Question 3 On pages E1-5 and E4-14 of Enclosure 1 to your January 12, 2007, submittal, you indicated that if an indication grows by an extreme amount (i.e., an outlier) that you will implement a methodology intended to address this issue. Given the text on these two pages are different, it is not clear whether the methodology would be submitted for NRC approval. Please confirm that this outlier methodology would be submitted for NRC approval prior to implementation. The NRC staff notes that its previous approval of POPCD relied on (1) modifications to the inspection and repair criteria to limit the potential for indications with high voltage growth; (2) other calculations performed by the licensee; and (3) additional reporting requirements that essentially require an assessment if the under predictions were significant (as discussed in the technical specifications).
TVA Response The outlier method would be submitted for NRC approval prior to implementation consistent with page E4-14 of Enclosure 4.
NRC Question 4 On pages E1-5 and E4-15 of Enclosure 1 to your January 12, 2007, submittal, you indicated that you performed rotating probe inspections of bobbin indications greater than 1.5 volts and no indications exceeded the 1.9 volt threshold for preventive repair. Since the actual practices in prior inspections may affect the potential for large voltage growth rates, please discuss whether any indications were preventively repaired as a result of these inspections (i.e., regardless of whether they exceeded the 1.9 volt threshold). If indications were repaired (to address the potential for large voltage growth rates),
E1-2


report 90-days after the SGs were returned to service regardless
discuss whether similar practices will be employed in all future inspections.
 
TVA Response During the end-of-cycles (EOCs) 12 and 13 inspections, 13 indications were preventively plugged at least in part as a result of the rotating pancake coil (RPC) inspection of indications over 1.5 volts. These indications were the largest RPC confirmed indications less than two bobbin volts. During the EOC-14 inspection, the indications above 1 volt were RPC tested.
of whether SG tube inspections were performed. For example, you
A small number of tubes (five indications) were preventively plugged. No specific guideline for preventive tube plugging was applied. The considerations for plugging included RPC volts, bobbin growth rates, number of RPC indications, etc.
 
TVA will continue to review large bobbin voltage, RPC confirmed indications for preventive tube plugging that do not exceed the 1.9-volt RPC volt threshold for repair. The option for preventive tube plugging will continue to be judgmental based on the overall NDE responses.
could specify that consistent with Technical Specification
NRC Question 5 You indicated that the number of high voltage indications in the POPCD database for SQN-2 does not satisfy the minimum requirements specified by the industry. As a result, you compared the SQN-2 database to the industry database. Please discuss what the effect would be on the SQN-2 POPCD curve if the SQN-1 [Sequoyah Nuclear Plant, Unit 1] and SQN-2 POPCD databases were combined. Although there may be differences in the noise levels (e.g., from denting) between the two units, there may be some insights gained on potential performance for higher voltage level indications.
 
6.9.1.16.1 the report would be submitted 90-days after the
 
initial entry into MODE 4 following completion of an inspection
 
performed in accordance with Specification 6.8.4.k, Steam
 
Generator (SG) Program.
Please note that the discussion in Section 2.0 of Enclosure 1 to your January 12, 2007, submittal does not match the wording in
 
your proposed Technical Specifications in Enclosure 2. The staff
 
assumed that the proposed wording in the Technical Specifications
 
is what you intended to propose.
TVA response  of this submittal provides reformatted TS and Bases markup pages that supersede the markups previously provided in
 
TVAs January 12, 2007 submittal. It may be noted that the
 
wording in Section 2.0 of TVAs January 12, 2007, submittal did
 
contain typographical errors that resulted in a mismatch with the
 
wording provided in Enclosure 2. The proposed TS wording
 
provided in Enclosure 2 was the intended wording.
NRC Question 2 Regarding the changes you intend to make to your Bases, the NRC does not have a copy of the Westinghouse letter that is
 
referenced. As a result, it can not comment on whether this
 
change is appropriate. The NRC expects that if the POPCD
 
methodology is approved that it would be implemented consistent E1-2 with the methodology provided to the staff to support its approval. The methodology in the referenced Westinghouse letter
 
may have been modified as a result of responses to the NRC
 
staffs request for additional information. Please discuss your
 
plans to ensure that the Bases reflect the actual POPCD
 
methodology that is approved by the NRC staff.
TVA Response TVA has revised the Bases pages to reflect the actual POPCD methodology approved by the NRC staff.  (Note: Enclosure 2 of
 
this submittal contains the Bases page markups with the
 
references that include the NRC letter that approves the POPCD
 
methodology for SQN Unit 2.)
NRC Question 3 On pages E1-5 and E4-14 of Enclosure 1 to your January 12, 2007, submittal, you indicated that if an indication grows by an
 
extreme amount (i.e., an outlier) that you will implement a
 
methodology intended to address this issue. Given the text on
 
these two pages are different, it is not clear whether the
 
methodology would be submitted for NRC approval. Please confirm
 
that this outlier methodology would be submitted for NRC approval
 
prior to implementation. The NRC staff notes that its previous
 
approval of POPCD relied on (1) modifications to the inspection
 
and repair criteria to limit the potential for indications with
 
high voltage growth; (2) other calculations performed by the
 
licensee; and (3) additional reporting requirements that
 
essentially require an assessment if the under predictions were
 
significant (as discussed in the technical specifications).
TVA Response The outlier method would be submitted for NRC approval prior to implementation consistent with page E4-14 of Enclosure 4
.NRC Question 4 On pages E1-5 and E4-15 of Enclosure 1 to your January 12, 2007, submittal, you indicated that you performed rotating probe
 
inspections of bobbin indications greater than 1.5 volts and no
 
indications exceeded the 1.9 volt threshold for preventive
 
repair. Since the actual practices in prior inspections may
 
affect the potential for large voltage growth rates, please
 
discuss whether any indications were preventively repaired as a
 
result of these inspections (i.e., regardless of whether they
 
exceeded the 1.9 volt threshold). If indications were repaired (to address the potential for large voltage growth rates),
E1-3 discuss whether similar practices will be employed in all future inspections.
TVA Response During the end-of-cycles (EOCs) 12 and 13 inspections, 13 indications were preventively plugged at least in part as a  
 
result of the rotating pancake coil (RPC) inspection of  
 
indications over 1.5 volts. These indications were the largest  
 
RPC confirmed indications less than two bobbin volts. During the  
 
EOC-14 inspection, the indications above 1 volt were RPC tested.
 
A small number of tubes (five indications) were preventively  
 
plugged. No specific guideline for preventive tube plugging was  
 
applied. The considerations for plugging included RPC volts, bobbin growth rates, number of RPC indications, etc.
TVA will continue to review large bobbin voltage, RPC confirmed indications for preventive tube plugging that do not exceed the 1.9-volt RPC volt threshold for repair
. The option for preventive tube plugging will continue to be judgmental based on the overall NDE responses.
NRC Question 5 You indicated that the number of high voltage indications in the POPCD database for SQN-2 does not satisfy the minimum  
 
requirements specified by the industry. As a result, you  
 
compared the SQN-2 database to the industry database. Please  
 
discuss what the effect would be on the SQN-2 POPCD curve if the  
 
SQN-1 [Sequoyah Nuclear Plant, Unit 1] and SQN-2 POPCD databases  
 
were combined. Although there may be differences in the noise  
 
levels (e.g., from denting) between the two units, there may be  
 
some insights gained on potential performance for higher voltage  
 
level indications.
In addition, please provide an enlarged view of the data above 1.0 volt in Figure 5.
In addition, please provide an enlarged view of the data above 1.0 volt in Figure 5.
Your justification for using the SQN-2 POPCD curve instead of the more limiting of the composite POPCD or SQN-2 POPCD curve is  
Your justification for using the SQN-2 POPCD curve instead of the more limiting of the composite POPCD or SQN-2 POPCD curve is largely qualitative and relies on the small differences between the curves. Since the POPCD curve is used to calculate the probability of burst under steam line break conditions and the amount of leakage under steam line break conditions, it would appear that a more appropriate comparison would be to evaluate the effects of the different POPCD curves on the structural and leakage integrity of the SG tubes. Please provide this assessment.
 
E1-3
largely qualitative and relies on the small differences between  
 
the curves. Since the POPCD curve is used to calculate the  


probability of burst under steam line break conditions and the  
Since this is a one-time assessment, please discuss your plans to submit a similar analysis until a sufficient number of high voltage data points are present at SQN-2. Alternatively, discuss your plans for using the most limiting of the POPCD curves.
TVA Response The large number of dents and high dent voltages at SQN-1 preclude meaningful combination of data from SQN-1 into POPCD for SQN-2. The addition of the SQN-1 data would not contribute meaningful data for application of POPCD and would significantly degrade the SQN-2 POPCD.
An enlarged view above 1.0 volt in Figure 5 is provided as Figure 5-1 (see page E1-30). The SQN-2 POPCD curve at the lower 95 percent is conservative relative to the industry curve while the nominal regression curves are nearly identical. The smaller number of data points in the SQN-2 POPCD data compared to the industry data lead to the larger uncertainties for the SQN-2 POPCD. However, the differences are small and have negligible influence on burst probability and leakage analyses.
The conclusion that small changes in POPCD have a negligible influence on burst and leakage is based on prior experience with POPCD analyses rather than qualitative judgment. See response to RAI-19 for examples of burst and leakage sensitivity to small changes in POPCD. In Table 19-1 (see page E1-24), the probability of burst and leakage are compared for the Addendum 5 POPCD and the SQN-2 POPCD. All other inputs are identical. The computation considered 250,000 Monte Carlo Trials. In both cases, the results are conservative relative to the as-found indications at end of cycle (EOC)-13. Although the probability of burst (POB) values are small, there are significant differences between the POB values computed using the two different POPCD functions. A test was run to determine if this difference was a consequence of the small number of Monte Carlo trials relative to the POB values. Table 19-1A (see page E1-25) shows the comparable results using 1 million Monte Carlo trials.
Table 19-1B (see page E1-25) shows that the percent difference between the POB using the two different POPCD curves is significantly less when a larger number of trials is used. This is because the Monte Carlo results are more reliable when more bursts are predicted. Similarly, it is expected that for cases where the probability of burst is greater, the difference in POB for slightly different POPCD curves will be small.
A sufficient number of high voltage data points to satisfy the criteria for a plant-specific POPCD is expected to be present when the EOC-14 POPCD is evaluated at the EOC-15 inspection. The earliest that POPCD can be implemented is the EOC-15 inspection.
Accordingly, implementation of POPCD on SQN-2 will be based on E1-4


amount of leakage under steam line break conditions, it would
plant specific data with no need to assess the more limiting of the plant specific and industry POPCD distributions.
NRC Question 6 On page E4-6 (1st bullet), you indicate that the end of cycle (EOC) inspection EOCn bobbin voltages are generally based on the inspection records for the EOCn. Please discuss your plans to report (in the 90-day report) any instances in which sizing is based on a reanalysis of the voltages previously reported. The staff notes that detection will always be based on past inspection records (as indicated in the first bullet).
TVA Response In any instance for which sizing is based on a reanalysis of the voltages previously reported, a description of the change and the basis for the change would be discussed in the 90-day report. No reanalyses have been applied to the POPCD data through the EOC-12 evaluations reported in the submittal. The option for reanalysis is included primarily to permit review of a EOCn missed indication with a very high EOCn+1 voltage for use in growth rate assessments.
NRC Question 7 On page E4-6 (2nd bullet), you indicate that the EOCn voltage for new EOCn+1 indications will be based on lookback analyses when the EOCn voltages are not available from the inspection record.
Please clarify when an EOCn voltage would be available for a flaw not reported in EOCn (or should the when in this sentence really be since). In addition (if when is the correct word in this sentence), please discuss why it is acceptable (in this case) not to confirm that the reported EOCn voltage actually corresponds to the flaw reported at EOCn+1.
TVA Response The word when in the sentence should be changed to the word since. The use of the word since will provide improved clarity for the 2nd bullet on page E4-6.
NRC Question 8 On page E4-7, you indicated that data supporting the adequacy of using the square root sum of the squares method for determining the inferred bobbin voltage from multiple rotating probe indications at a tube support plate was provided by another utility (in an August 18, 2004 letter). Since this information E1-5


appear that a more appropriate comparison would be to evaluate
was specific to this utility, please provide a similar plot demonstrating that the approach is currently adequate for SQN-2 (future assessments will be provided in the 90-day report).
TVA Response Figure 8-1 (see page E1-31) shows the inferred bobbin voltage from multiple +Point indications compared to the measured bobbin voltages. The inferred bobbin volts are obtained as the square root of the sum of squares of the bobbin volts obtained for each
+Point indication from the correlation of bobbin volts to +Point volts. It is seen that the inferred bobbin volts are conservative compared to the measured bobbin volts for nearly all measurements. The conservatism results from the relatively high bobbin volts obtained from the correlation with +Point volts as shown in Figure 8-2 (see page E1-31), which represents the correlation updated to include EOC-14 data. The polynomial fit to the 95 percent confidence on the mean regression line is used to infer the bobbin volts. It is seen that the bobbin volts inferred from the +Point volts is always greater than unity such that the multiple +Point indication correlation leads to bobbin volts greater than 1.5. Figure 8-2 is further discussed in RAI-9.
NRC Question 9 Figure 2 provides a correlation for assigning an inferred bobbin voltage to indications detected only with a rotating probe. A similar curve is provided in Figure 3-13 of your March 20, 2007 letter, which submitted the SQN-2 Cycle 14 90-day SG report.
Please discuss the differences in these curves. Please discuss if there have been significant changes in this correlation with time. If so, discuss whether a composite curve is more appropriate or whether a conservative lower bound to any single cycle data is appropriate. In addition, please confirm that there are no data from axially oriented outside diameter stress corrosion cracking indications not detectable by bobbin (AONDBs) such that an assessment of the adequacy of this correlation can currently be assessed. The staff notes that it appears that the prior practice was to plug AONDBs on detection (page E4-17).
TVA Response Figure 2 applies bobbin voltages inferred from the 95 percent confidence on the mean regression correlation of bobbin with
+Point volts. This is consistent with Section 10.1 of Addendum 6 to the alternate repair criteria (ARC) database (Reference 1) and prior licensed POPCD applications. Figure 3-13 of the 90-day report infers bobbin voltages from the 95 percent prediction E1-6


the effects of the different POPCD curves on the structural and
interval of the correlation, which yields more conservative bobbin voltage predictions.
 
leakage integrity of the SG tubes. Please provide this
 
assessment.
E1-4 Since this is a one-time assessment, please discuss your plans to submit a similar analysis until a sufficient number of high
 
voltage data points are present at SQN-2. Alternatively, discuss
 
your plans for using the most limiting of the POPCD curves.
TVA Response The large number of dents and high dent voltages at SQN-1 preclude meaningful combination of data from SQN-1into POPCD for
 
SQN-2. The addition of the SQN-1 data would not contribute
 
meaningful data for application of POPCD and would significantly
 
degrade the SQN-2 POPCD.
An enlarged view above 1.0 volt in Figure 5 is provided as Figure 5-1 (see page E1-30). The SQN-2 POPCD curve at the lower
 
95 percent is conservative relative to the industry curve while
 
the nominal regression curves are nearly identical. The smaller
 
number of data points in the SQN-2 POPCD data compared to the
 
industry data lead to the larger uncertainties for the SQN-2
 
POPCD. However, the differences are small and have negligible
 
influence on burst probability and leakage analyses.
The conclusion that small changes in POPCD have a negligible influence on burst and leakage is based on prior experience with
 
POPCD analyses rather than qualitative judgment. See response
 
to RAI-19 for examples of burst and leakage sensitivity to small
 
changes in POPCD. In Table 19-1 (see page E1-24), the
 
probability of burst and leakage are compared for the Addendum 5
 
POPCD and the SQN-2 POPCD. All other inputs are identical. The
 
computation considered 250,000 Monte Carlo Trials. In both
 
cases, the results are conservative relative to the as-found
 
indications at end of cycle (EOC)-13. Although the probability
 
of burst (POB) values are small, there are significant
 
differences between the POB values computed using the two
 
different POPCD functions. A test was run to determine if this
 
difference was a consequence of the small number of Monte Carlo
 
trials relative to the POB values. Table 19-1A (see page E1-25)
 
shows the comparable results using 1 million Monte Carlo trials.
 
Table 19-1B (see page E1-25) shows that the percent difference
 
between the POB using the two different POPCD curves is
 
significantly less when a larger number of trials is used. This
 
is because the Monte Carlo results are more reliable when more
 
bursts are predicted. Similarly, it is expected that for cases
 
where the probability of burst is greater, the difference in POB
 
for slightly different POPCD curves will be small.
A sufficient number of high voltage data points to satisfy the criteria for a plant-specific POPCD is expected to be present
 
when the EOC-14 POPCD is evaluated at the EOC-15 inspection. The
 
earliest that POPCD can be implemented is the EOC-15 inspection.
 
Accordingly, implementation of POPCD on SQN-2 will be based on E1-5 plant specific data with no need to assess the more limiting of the plant specific and industry POPCD distributions.
NRC Question 6 On page E4-6 (1 st bullet), you indicate that the end of cycle (EOC) inspection EOC n bobbin voltages are generally based on the inspection records for the EOC
: n. Please discuss your plans to report (in the 90-day report) any instances in which sizing is
 
based on a reanalysis of the voltages previously reported. The
 
staff notes that detection will always be based on past
 
inspection records (as indicated in the first bullet).
TVA Response In any instance for which sizing is based on a reanalysis of the voltages previously reported, a description of the change and the
 
basis for the change would be discussed in the 90-day report. No
 
reanalyses have been applied to the POPCD data through the
 
EOC-12 evaluations reported in the submittal. The option for
 
reanalysis is included primarily to permit review of a EOC n missed indication with a very high EOC n+1 voltage for use in growth rate assessments.
NRC Question 7 On page E4-6 (2 nd bullet), you indicate that the EOC n voltage for new EOC n+1 indications will be based on lookback analyses when the EOC n voltages are not available from the inspection record.
Please clarify when an EOC n voltage would be available for a flaw not reported in EOC n (or should the when in this sentence really be since). In addition (if when is the correct word
 
in this sentence), please discuss why it is acceptable (in this
 
case) not to confirm that the reported EOC n voltage actually corresponds to the flaw reported at EOC n+1.TVA Response The word when in the sentence should be changed to the word since. The use of the word since will provide improved
 
clarity for the 2 nd bullet on page E4-6.
NRC Question 8 On page E4-7, you indicated that data supporting the adequacy of using the square root sum of the squares method for determining
 
the inferred bobbin voltage from multiple rotating probe
 
indications at a tube support plate was provided by another
 
utility (in an August 18, 2004 letter). Since this information E1-6 was specific to this utility, please provide a similar plot demonstrating that the approach is currently adequate for SQN-2 (future assessments will be provided in the 90-day report).
TVA Response Figure 8-1 (see page E1-31) shows the inferred bobbin voltage from multiple +Point indications compared to the measured bobbin
 
voltages. The inferred bobbin volts are obtained as the square
 
root of the sum of squares of the bobbin volts obtained for each
 
+Point indication from the correlation of bobbin volts to +Point
 
volts. It is seen that the inferred bobbin volts are
 
conservative compared to the measured bobbin volts for nearly all
 
measurements. The conservatism results from the relatively high
 
bobbin volts obtained from the correlation with +Point volts as
 
shown in Figure 8-2 (see page E1-31), which represents the
 
correlation updated to include EOC-14 data. The polynomial fit
 
to the 95 percent confidence on the mean regression line is used
 
to infer the bobbin volts. It is seen that the bobbin volts
 
inferred from the +Point volts is always greater than unity such
 
that the multiple +Point indication correlation leads to bobbin
 
volts greater than 1.5. Figure 8-2 is further discussed in
 
RAI-9.NRC Question 9 Figure 2 provides a correlation for assigning an inferred bobbin voltage to indications detected only with a rotating probe. A
 
similar curve is provided in Figure 3-13 of your March 20, 2007
 
letter, which submitted the SQN-2 Cycle 14 90-day SG report.
 
Please discuss the differences in these curves. Please discuss
 
if there have been significant changes in this correlation with
 
time. If so, discuss whether a composite curve is more
 
appropriate or whether a conservative lower bound to any single
 
cycle data is appropriate. In addition, please confirm that
 
there are no data from axially oriented outside diameter stress
 
corrosion cracking indications not detectable by bobbin (AONDBs)
 
such that an assessment of the adequacy of this correlation can
 
currently be assessed. The staff notes that it appears that the
 
prior practice was to plug AONDBs on detection (page E4-17).
TVA Response Figure 2 applies bobbin voltages inferred from the 95 percent confidence on the mean regression correlation of bobbin with
 
+Point volts. This is consistent with Section 10.1 of Addendum 6
 
to the alternate repair criteria (ARC) database (Reference 1) and
 
prior licensed POPCD applications. Figure 3-13 of the 90-day
 
report infers bobbin voltages from the 95 percent prediction E1-7 interval of the correlation, which yields more conservative bobbin voltage predictions.
Figure 8-2 (see page E1-31) shows a revision of the submittals Figure 2 bobbin to +Point volt correlation for SQN-2 EOC-14 data.
Figure 8-2 (see page E1-31) shows a revision of the submittals Figure 2 bobbin to +Point volt correlation for SQN-2 EOC-14 data.
The +Point data for this correlation includes the single axial indication (SAI) data from the EOC-14 inspection.
Upon approval for POPCD implementation, the 95 percent confidence on the mean bobbin to +Point voltage correlation will be applied to obtain inferred bobbin voltages consistent with Figure 2 of the transmittal and Figure 8-2 (see page E1-31) of this response.
The adequacy of the correlation cannot be assessed since the prior practice was to plug the indications.
If/once an AONDB becomes detectable by bobbin, a comparison of the actual bobbin voltage to what would be expected based on the inferred bobbin voltage from the prior inspection and typical voltage growth will be included in the 90-day report.
NRC Question 10 On page E4-9, you indicated that if the p-value is greater than 5 percent, you will propose an alternate probability of detection (POD) model and submit the recommendation to the NRC for approval. Given that it may take time for the NRC to review any changes to the POD model, please discuss the model to be used in the interim pending staff review of the alternate model. The NRC staff notes that it previously accepted the use of a default value of 0.6 for POD as an acceptable alternative.
TVA Response A default value of 0.6 for POD would be used as an alternative POD in the event that the p-value for a POPCD analysis is greater than five percent. However, the likelihood of the p-value increasing from less than 2.9 x 10-7 to 0.05 as more data is accumulated in the database is extremely low.
NRC Question 11 On page E4-15, you indicate that an assessment for the onset of voltage dependent growth should be performed and the methods of Reference 1 applied when growth rates show a dependence on the beginning of cycle voltage. Please confirm that this assessment will be performed. In addition, discuss whether there are any differences in the voltage dependent growth methodology discussed in Reference 1 and the methodology approved by the NRC staff in prior POPCD approvals. If there are any differences, please justify them.
E1-7


The +Point data for this correlation includes the single axial
TVA Response Assessments for the onset of voltage dependent growth (VDG) will be performed and documented in each 90-day report. There are no differences between the VDG methods of Section 10.3 of Reference 1 and the methodology approved by the NRC staff in prior POPCD approvals. It can be noted that Section 10.3 includes examples based on applying the methods to the plant having a previously approved POPCD.
 
NRC Question 12 On page E4-16, you indicated that a rotating probe (+Point) inspection would be performed for +Point confirmed indications at EOCn that are not detected by bobbin at EOCn+1. Please confirm that this is Note 1 in Table 1 (rather than Note 3 in Table 1 as indicated in the text).
indication (SAI) data from the EOC-14 inspection.
Upon approval for POPCD implementation, the 95 percent confidence on the mean bobbin to +Point voltage correlation will be applied
 
to obtain inferred bobbin voltages consistent with Figure 2 of
 
the transmittal and Figure 8-2 (see page E1-31) of this response.
 
The adequacy of the correlation cannot be assessed since the
 
prior practice was to plug the indications.
If/once an AONDB becomes detectable by bobbin, a comparison of the actual bobbin voltage to what would be expected based on the
 
inferred bobbin voltage from the prior inspection and typical
 
voltage growth will be included in the 90-day report.
NRC Question 10 On page E4-9, you indicated that if the p-value is greater than 5 percent, you will propose an alternate probability of detection (POD) model and submit the recommendation to the NRC for
 
approval. Given that it may take time for the NRC to review any
 
changes to the POD model, please discuss the model to be used in
 
the interim pending staff review of the alternate model. The NRC
 
staff notes that it previously accepted the use of a default
 
value of 0.6 for POD as an acceptable alternative.
TVA Response A default value of 0.6 for POD would be used as an alternative POD in the event that the p-value for a POPCD analysis is greater
 
than five percent. However, the likelihood of the p-value
 
increasing from less than 2.9 x 10
-7 to 0.05 as more data is accumulated in the database is extremely low.
NRC Question 11 On page E4-15, you indicate that an assessment for the onset of voltage dependent growth should be performed and the methods of
 
Reference 1 applied when growth rates show a dependence on the
 
beginning of cycle voltage. Please confirm that this assessment
 
will be performed. In addition, discuss whether there are any
 
differences in the voltage dependent growth methodology discussed
 
in Reference 1 and the methodology approved by the NRC staff in
 
prior POPCD approvals. If there are any differences, please
 
justify them.
E1-8 TVA Response Assessments for the onset of voltage dependent growth (VDG) will be performed and documented in each 90-day report. There are no  
 
differences between the VDG methods of Section 10.3 of  
 
Reference 1 and the methodology approved by the NRC staff in  
 
prior POPCD approvals. It can be noted that Section 10.3  
 
includes examples based on applying the methods to the plant  
 
having a previously approved POPCD.
NRC Question 12 On page E4-16, you indicated that a rotating probe (+Point) inspection would be performed for +Point confirmed indications at  
 
EOC n that are not detected by bobbin at EOC n+1. Please confirm that this is Note 1 in Table 1 (rather than Note 3 in Table 1 as  
 
indicated in the text).
TVA Response It is correct that Note 1 in Table 1 should have been referenced on page E4-16 rather than Note 3.
TVA Response It is correct that Note 1 in Table 1 should have been referenced on page E4-16 rather than Note 3.
NRC Question 13 On page E4-17, you indicate that you assign a through-wall depth (i.e., a percent code) to bobbinindications confirmed with a  
NRC Question 13 On page E4-17, you indicate that you assign a through-wall depth (i.e., a percent code) to bobbin indications confirmed with a rotating probe to be volumetric indications. Please confirm that this applies only to volumetric wear indications and thinning/wastage indications rather than to volumetric indications attributed to intergranular attack or closely spaced cracks. Please confirm that the voltage based repair criteria are applied to volumetric outside diameter cracking indications (including intergranular attack). If not, please confirm that these indications are plugged on detection.
 
TVA Response It is correct that depth assignments for volumetric indications are only made for indications attributed to wear and thinning/wastage indications. The voltage based repair criteria are applied to intergranular attack or volumetric interpretations for outside diameter cracking indications.
rotating probe to be volumetric indications. Please confirm that  
E1-8
 
this applies only to volumetric wear indications and  
 
thinning/wastage indications rather than to volumetric  
 
indications attributed to intergranular attack or closely spaced  
 
cracks. Please confirm that the voltage based repair criteria  
 
are applied to volumetric outside diameter cracking indications (including intergranular attack). If not, please confirm that these indications are plugged on detection.
TVA Response It is correct that depth assignments for volumetric indications are only made for indications attributed to wear and  
 
thinning/wastage indications. The voltage based repair criteria  
 
are applied to intergranular attack or volumetric interpretations  
 
for outside diameter cracking indications.
E1-9 NRC Question 14 On page E4-18, you indicated that no reevaluation was performed of the EOC 9 data for a 2.03 volt indication that was detected at
 
EOC 10. Please confirm that future assessments of POPCD that use
 
previous data will be re-evaluated to determine the voltage of
 
the potentially missed indication. In addition, please discuss


what growth rate was assigned to this indication if the previous  
NRC Question 14 On page E4-18, you indicated that no reevaluation was performed of the EOC 9 data for a 2.03 volt indication that was detected at EOC 10. Please confirm that future assessments of POPCD that use previous data will be re-evaluated to determine the voltage of the potentially missed indication. In addition, please discuss what growth rate was assigned to this indication if the previous data were not reviewed (this is important from a benchmarking standpoint).
 
data were not reviewed (this is important from a benchmarking  
 
standpoint).
TVA Response A review of the EOC-10 90-day report showed no 2.03 volt indication at SG 3, R32C17 H01 as stated on page E4-18.
TVA Response A review of the EOC-10 90-day report showed no 2.03 volt indication at SG 3, R32C17 H01 as stated on page E4-18.
Supporting documentation for that report noted that the 2.03 volt indication at SG 3, R32C17 H01 which was originally reported as a distorted support indication (DSI) was RPC tested and determined to be an ID flaw, and thus it was eliminated from the axial outer-diameter stress corrosion cracking (ODSCC) analysis.
Therefore, no look back to determine an ODSCC growth rate was performed. This information however was not received by the person developing the POPCD. As described on page E4-18, the average growth rate of 0.1 volt was assigned to this indication to obtain a 1.93 volt missed indication at EOC-9, which is the largest undetected indication in the POPCD database. This remains as a small conservatism in the SQN-2 POPCD. The benchmark predictive calculations for EOC-11 in Table 8 consider the 0.1 volt growth rate for this indication. The largest growth in the EOC-11 predictive analysis is 0.7 volts/effective full-power year.
TVA confirms that future assessments of POPCD that use previous data will be reevaluated to determine the voltage of the potentially missed indication.
NRC Question 15 On page E4-18, you indicate the composite POPCD data contains 11 indications found only with a rotating probe (Column F of Table 4) although there were only six occurrences. You further indicate that the rotating probe only detections are counted as missed indications in two successive cycle POPCD evaluations even though they were repaired on detection. Please clarify this discussion. If an indication was initially detected at EOCn+1 and subsequently plugged, it does not appear (to the staff) that the indications should be counted twice based on a review of Table 1.
E1-9


Supporting documentation for that report noted that the 2.03 volt
TVA Response When the indication is found only by RPC at Cycle n+1, the indication is included as a missed bobbin indication at Cycle n (e.g., most frequently bobbin no degredation detected [NDD]
 
indication bobbin NDD intersection [BND] w/o RPC in Table 1) and entered in Column F in Table 4. When Cycle n+2 is completed, the indication is included as a missed bobbin indication at Cycle n+1 (Cycle n BND w/RPC detected [RDD] in Table 1). In most cases, the indication remains bobbin NDD and RPC detected at EOC n+2 (column F of Table 4) although the indication could be a new indication in Column E or D of Table 4. Since these indications were preventively plugged when found at SQN-2, the indication is missed at Cycle n+1 based on BND w/RDD and plugged as shown in Table 2 for Cycle n.
indication at SG 3, R32C17 H01 which was originally reported as a
NRC Question 16 Please provide an enlarged view of the data above 1.0 volt in Figure 4. In addition, please discuss what POPCD curve is required to be used in the assessments given that the POD above 1.0 volt for the cycle 12 data is less than the corresponding POD for the composite dataset.
 
TVA Response Figure 16-1 (see page E1-32) provides the requested data above 1.0 volt from Figure 4 of the transmittal.
distorted support indication (DSI) was RPC tested and determined
On page E4-19 of TVAs January 12, 2007 transmittal, it is noted that the multi-cycle POPCD is considered more appropriate for future operational assessments than any one cycle of POPCD data.
 
On page E4-23, first bullet, it is noted that differences between the multi-cycle POPCD and the last cycle should be assessed in the 90-day report relative to the potential for significant changes in detection capability. Recognizing the number of data points for any one cycle of POPCD is considered to be too small to control the expected POPCD for the next cycle, if there are significant negative trends in POPCD, appropriate adjustments will be made to POPCD to ensure reliable projections continue to be made. If there are significant negative trends in POPCD, other corrective actions may also be necessary (e.g., chemical cleaning to reduce noise, other actions to reduce noise in the ECT, . . .).
to be an ID flaw, and thus it was eliminated from the axial
NRC Question 17 Regarding Table 7, please confirm that the number of data points in the POPCD curve for EOC 7 through 12 is only slightly greater than the number of datapoints from EOC 12. Since a number of datapoints should be present from year to year, the staff would E1-10
 
outer-diameter stress corrosion cracking (ODSCC) analysis.
 
Therefore, no look back to determine an ODSCC growth rate was
 
performed. This information however was not received by the
 
person developing the POPCD. As described on page E4-18, the
 
average growth rate of 0.1 volt was assigned to this indication
 
to obtain a 1.93 volt missed indication at EOC-9, which is the
 
largest undetected indication in the POPCD database. This
 
remains as a small conservatism in the SQN-2 POPCD. The
 
benchmark predictive calculations for EOC-11 in Table 8 consider
 
the 0.1 volt growth rate for this indication. The largest growth
 
in the EOC-11 predictive analysis is 0.7 volts/effective full-
 
power year.
TVA confirms that future assessments of POPCD that use previous data will be reevaluated to determine the voltage of the
 
potentially missed indication.
NRC Question 15 On page E4-18, you indicate the composite POPCD data contains 11 indications found only with a rotating probe (Column F of
 
Table 4) although there were only six occurrences. You further
 
indicate that the rotating probe only detections are counted as
 
missed indications in two successive cycle POPCD evaluations even
 
though they were repaired on detection. Please clarify this
 
discussion. If an indication was initially detected at EOC n+1 and subsequently plugged, it does not appear (to the staff) that the
 
indications should be counted twice based on a review of Table 1.
E1-10 TVA Response When the indication is found only by RPC at Cycle n+1, the indication is included as a missed bobbin indication at Cycle n (e.g., most frequently bobbin no degredation detected [NDD]
indication bobbin NDD intersection [BND]w/o RPC in Table 1) and  
 
entered in Column F in Table 4. When Cycle n+2 is completed, the  
 
indication is included as a missed bobbin indication at Cycle n+1 (Cycle n BND w/RPC detected [RDD] in Table 1). In most cases, the indication remains bobbin NDDand RPC detected at EOC n+2 (column F of Table 4) although the indication could be a new  
 
indication in Column E or D of Table 4. Since these indications  
 
were preventively plugged when found at SQN-2, the indication is  
 
missed at Cycle n+1 based on BND w/RDD and plugged as shown in  
 
Table 2 for Cycle n.
NRC Question 16 Please provide an enlarged view of the data above 1.0 volt in Figure 4. In addition, please discuss what POPCD curve is  
 
required to be used in the assessments given that the POD above  
 
1.0 volt for the cycle 12 data is less than the corresponding POD  
 
for the composite dataset.
TVA Response Figure 16-1 (see page E1-32) provides the requested data above 1.0 volt from Figure 4 of the transmittal. On page E4-19 of TVAs January 12,2007 transmittal, it is noted that the multi-cycle POPCD is considered more appropriate for  
 
future operational assessments than any one cycle of POPCD data.  
 
On page E4-23, first bullet, it is noted that differences between  
 
the multi-cycle POPCD and the last cycle should be assessed in  
 
the 90-day report relative to the potential for significant  
 
changes in detection capability. Recognizing the number of data  
 
points for any one cycle of POPCD is considered to be too small  
 
to control the expected POPCD for the next cycle, if there are  
 
significant negative trends in POPCD, appropriate adjustments  
 
will be made to POPCD to ensure reliable projections continue to  
 
be made. If there are significant negative trends in POPCD, other corrective actions may also be necessary (e.g., chemical  
 
cleaning to reduce noise, other actions to reduce noise in the  
 
ECT, . . .).
NRC Question 17 Regarding Table 7, please confirm that the number of data points in the POPCD curve for EOC 7 through 12 is only slightly greater  
 
than the number of datapoints from EOC 12. Since a number of  
 
datapoints should be present from year to year, the staff would E1-11 have expected a large number of data points for the EOC 7 through 12 composite curve and a significantly less number of datapoints
 
for any one cycle (unless a significant number of new indications
 
were identified in EOC 13).
TVA Response As noted in the following paragraph, there is a large difference in the number of data points between EOC-7 to EOC-12 and only
 
EOC-12. However, Table 7 has erroneously entered the POPCD
 
parameters for EOC-8 to EOC-12 for EOC-12 parameters. The
 
Corrected Table 7 is attached (see page E1-24) and shows the
 
correct differences in the number of points as discussed below.
 
The POPCD plot for EOC-12 in Figure 4 of the submittal is
 
correct.The number of data points for EOC-7 to EOC-12 (Table 4 of submittal) is 4524 for detection at EOC n and 1869 for no detection at EOC n where the corresponding values for only EOC-12 (Table 6 of submittal) are 1494 and 361. These data represent a
 
large number of data points for the EOC-7 to EOC-12 data and a
 
significantly smaller number of data points for Cycle 12 alone.
NRC Question 18 Please confirm that no adjustment to the voltage growth rate distribution is performed when the average growth rate decreases
 
from one cycle to the next.
TVA Response As noted in Section 4.2, page E4-15 of the POPCD submittal, the incremental increase in average growth rate will be implemented
 
when the average growth rate shows an increase for the just
 
completed cycle. The intent of this statement is that the
 
adjustment is made only when the average growth rate increases
 
from one cycle to the next, and no adjustment is performed when
 
the average growth rate decreases. This is further noted in the
 
step-by-step description of developing growth rates given in the
 
response to RAI-22.
NRC Question 19 In the benchmark analysis, you used the composite POPCD curve from Cycle 7 through 12. This does not appear to be appropriate
 
since some of the data was not present at the time of the
 
inspections (and using future data to predict past trends would
 
normally be expected to provide reasonable results). As a
 
result, please repeat the benchmark analysis with POPCD data E1-12 available at the time the inspections were performed (use of the latest burst and leakage correlations and actual cycle lengths is
 
acceptable). In addition, this benchmarking should not include
 
the datapoint that exhibited extreme voltage growth since
 
actions were taken to limit the possibility of such extreme
 
voltage growths and inclusion of this datapoint can skew the
 
results. This datapoint should not be included in the beginning
 
of cycle voltage distribution or the growth rate data (i.e., the
 
average growth rate or the distribution of growth rates). As
 
part of this benchmarking analysis, please include an analysis of
 
the EOC 14 inspection data completed in Fall 2006. Please
 
include in this response the database used for assessing the
 
integrity of the tubes, the actual cycle length, and the cycle
 
length assumed in the benchmarking analysis. Lastly, discuss
 
whether there has been any significant preventive plugging of
 
tubes such that the benchmarking analysis (or growth rate
 
distributions) may have been skewed.
TVA Response As discussed in page E4-20 of the submittal, the SQN-2 composite POPCD was used for all prior cycles since the industry POPCD for
 
these cycles (required per Section 3.3, pages E4-10 and E4-11
 
when inadequate plant specific data are available) is essentially
 
the same as the Sequoyah POPCD. Figure 19-1 (see page E1-33)
 
shows the comparison of the industry Addendum 5 POPCD with the
 
SQN-2 POPCD. It is seen that these two distributions are
 
essentially the same with the larger uncertainties in the SQN-2
 
POPCD leading to a lower 95 percent POPCD slightly smaller than
 
the industry POPCD below about 0.2 volt and a slightly higher
 
POPCD above about 0.3 volt. Page E4-39, Figure 5 compares the
 
SQN-2 POPCD with the industry POPCD updated to the time of the
 
SQN-2 POPCD submittal. In this case, the lower 95 percent SQN-2
 
POPCD is in excellent agreement with the industry POPCD. It is
 
noted in Table 7-4 of the January 12, 2007 TVA submittal that
 
there is essentially no change in the industry POPCD data between
 
Addenda 4 and 5. Since the industry POPCDs for Addenda 4 to 6
 
and the SQN-2 POPCD are essentially the same and burst pressures
 
or leak rates are not sensitive to small changes in POD, there
 
was no need to change the POPCD distribution between the
 
projected EOC-11 to EOC-13 predictions in Table 9, page E4-33.
To numerically demonstrate the negligible influence of small differences in POD, the EOC-13 projections were repeated using
 
the Addendum 5 POPCD. The results are shown in the lower part of
 
Table 19-1 (see page E1-33), where the projected leak rates, number of indications, and maximum volts are essentially
 
unchanged by the change in POPCD. Small differences are seen in
 
the burst probabilities with the SQN-2 POPCD yielding slightly
 
lower burst probabilities, which is likely due to the modest E1-13 increase in the SQN-2 POPCD above about 0.3 volt. For benchmarking, the objective is to demonstrate margins over the
 
as-found conditions. This objective is satisfied by both the
 
SQN-2 and Addendum 5 POPCD distributions. The use of the SQN-2
 
POPCD is thus more realistic than using the Addendum 5 POPCD
 
since it yields slightly smaller burst probability margins. The
 
Addendum 5 POPCD would be the required benchmarking POD for
 
EOC-13 projections if there were significant differences from the
 
SQN-2 POPCD. The Addenda 4 and 5 industry POPCDs would have been
 
the required POPCD distributions for projecting Cycles 11 and 12, respectively. The negligible differences in burst pressures and
 
leak rates between applying the Addendum 5 POPCD and the SQN-2
 
Cycles 7-12 POPCD together with the negligible differences in
 
POPCD between Addendum 4 and Cycles 7-12 support the use of the
 
Cycles 7-12 POPCD for all benchmarking analyses in Table 8 of the
 
submittal. The actual cycle length in EFPD is compared to the
 
length of time in the analyses in Table 19-5 (see page E1-27).
 
EOC-11 used the actual time, and the other cases used the times
 
that were used in the predictions in the respective 90-day
 
reports.The benchmarking analyses for Cycles 13 and 14 are performed including and not including the one large growth rate of 5.67
 
volts/effective full power year found for Cycle 12 for a
 
comparison of the resulting POB and leakage. It is appropriate
 
to exclude the large growth rate because of the preventive
 
measures discussed in RAI-4. In this case, the bobbin voltages
 
grew at modest rates from 1.06 volts at EOC-7 to 1.98 volts at
 
EOC-11. The indication was not +Point inspected prior to the
 
large 9.76 volts found at EOC-12. The indication would have been
 
+Point inspected at EOC-11 based on the preventive repair
 
guideline currently being applied to inspect all bobbin DSI
 
indications greater than 1.7 volts. It is not clear that a
 
+Point inspection at EOC-11 would have led to a +Point amplitude
 
greater than 1.9 volts that would have required repair. The
 
results are shown at the bottom of Table 19-1 (see page E1-24).
 
It is seen that exclusion of the high growth rate value reduces
 
the burst probabilities and leak rates although the EOC-13
 
projections remain conservative compared to the as-found results.
Table 19-2 (see page E1-26) provides the EOC-14 projections and as-found results at EOC-14 for projections with and without the
 
large growth rate found in Cycle 12. The columns in the table
 
identify the ARC burst and leak rate correlations, the growth
 
rate used, and the POPCD used in the analyses. The EOC-14
 
projections with the large growth rate included are the
 
projections given in Table 9 of the submittal. The projections
 
are based on a Cycle 14 length of 545 days where the actual cycle
 
length was 537.1 days. The observations from the comparison are
 
as follows:
E1-14 1)  The number of indications is underpredicted when POPCD is used. The extent of the underprediction is shown in
 
Table 19-3A (see page E1-26).
: 2)  Using POPCD, leakage is conservatively predicted for all SGs. The results using the reduced growth rate are
 
much closer to the as-found results.
: 3)  Using POPCD and the large growth rate due to the large indication at EOC-12, POB is conservatively predicted
 
for all SGs.
: 4)  Using POPCD and the growth rate obtained by ignoring the large indication at EOC-12, POB is conservatively
 
predicted for SGs 1, 2, and 3, and is underpredicted by
 
1.11 x 10-4 using the reportedDSIs. This is an underprediction of one tenth of the value for
 
considering method revision (0.001) in the Diablo
 
Canyon TS as approved by NRC.
Based on these observations, the underprediction of the number of indications was investigated. It was noted that the definition
 
of what would be called a DSI was changed in the EOC-14
 
inspection from the definition used previously. In EOC-14, a
 
bobbin indication that appeared to be inside diameter (ID), and
 
was either RPC inspected and found to be NDD or was reviewed by
 
history to be unchanged and previously RPC tested as NDD, that
 
indication was considered to be a DSI and included in the
 
indication count and the integrity and leakage analysis. Table
 
19-3B (see page E1-26) shows what the indication count at EOC 14
 
would have been if the definition of a DSI were unchanged from
 
EOC-13. This table shows that the underprediction would be
 
significantly less, and within the limits specified (15 percent
 
or 150 indications) in the Diablo Canyon TS as approved by NRC.
 
The probability of burst and leakage were recomputed for EOC-14
 
results using the revised indication population. It is seen in
 
Table 19-4 (see page E1-27) that the results are slightly but not
 
significantly more favorable. This is because the probability of
 
burst and leakage are very dependent on the largest indications
 
which were not affected by the revision.
It is expected that this change in definition will result in a one-time step change in the number of indications so the
 
predictions for EOC-16 and beyond will not continue to show this
 
level of underprediction. The projections of record for EOC-15
 
were made in the 90-day report using the approved POD of 0.6.
 
Projections are planned to be made for EOC-15 for benchmarking
 
purposes using the approved POPCD prior to EOC-15. It is
 
expected that POPCD may be used for the projections of record
 
from EOC-16 forward.
E1-15 There were only 13 tubes preventively plugged at EOC-12 and EOC-
: 13. These are properly treated as plugged tubes in the benchmark
 
projections and the EOC actuals include the influence of all
 
plugging at the prior EOC. The growth rate from EOC n-1 to EOC n includes the growth for all tubes plugged at EOC
: n. The growth rate from EOC n to EOC n+1 would not include the growth for any tubes plugged at EOC n.NRC Question 20 Regarding your continuing assessment of the inspection results, please confirm that an assessment will be performed for any
 
underpredictions in order to assess the probable cause. As
 
currently written, it is not clear to the staff whether the
 
assessments would only be performed when the quantitative
 
criteria listed in Section 7.0 of your submittal are exceeded.
 
In addition, please confirm that the assessment of the
 
underprediction of the number of indications will include the
 
potential need to increase the number of indications regardless
 
of whether the indications that need to be increased are low or
 
high voltage. Lastly, please confirm that you will provide an
 
update (based on the results of your inspection) to Table 7 for
 
the composite and one-cycle POPCD curve for SQN-2 in your 90-day
 
report.TVA Response As noted in the first bullet of Section 7.0, page E4-22, an assessment of the probable cause for any underpredictions, including potential corrective actions and potential changes to
 
probability of detection and or growth methodology, will be
 
included in the 90-day report. This assessment is expected to be
 
qualitative and no changes in ARC analysis methods are expected
 
to be immediately implemented in operational assessments. An
 
assessment of the potential need to revise the ARC analysis
 
methods will be performed if the underpredictions in burst
 
probability or leak rate exceed the values given in the second
 
bullet in Section 7.0. This assessment is expected to include
 
quantitative evaluations of proposed changes to the analysis
 
methods that might be immediately implemented in the operational
 
assessment.
As noted in the third bullet of Section 7.0, an assessment will be made of the need to increase the number of predicted low
 
voltage indications if the total number of as-found indications
 
is underestimated by greater the 15 percent or by greater than
 
150 indications. This guidance is based on the small influence
 
of low voltage indications on burst probability and leak rates.
 
An underprediction of high voltage indications leading to an
 
underprediction of burst probability or leak rate would lead to E1-16 the assessments of growth rates and POD required by the first or second bullet of Section 7.0.
TVA will provide an update (based on the results of each inspection) to Table 7 for the composite and one-cycle POPCD
 
curve for SQN-2 in the 90-day report.
NRC Question 21 On page E1-5, you indicate that upon approval of the POPCD methodology the growth ratesused in the operational assessments
 
will be obtained as the bounding growth rate of the SGs and the
 
composite average growth over the last two cycles of operation.
 
Please clarify this statement. For example, is the composite
 
average growth, the composite from all SGs over one cycle (or two
 
cycles)?  If the composite is from all SGs, discuss whether it is
 
necessary to assess whether the average growth rate from one SG
 
is increasing at a rate greater than the other SGs (implying that
 
this SG may need a larger increase in the average growth rate
 
than the composite growth rate would suggest).
TVA Response The average growth rates for each SG for the past three cycles are shown in Table 21-1 (see page E1-28). Several observations
 
can be made. First, the average growth rates are small, with one
 
exception below 0.1 volt/EFPY; second, growth rates increase and
 
decrease for each SG; and third, the SG with the largest average
 
growth in one cycle is not the one with the largest average
 
growth in the next cycle. The increase in average growth rate
 
for each SG based on Table 21-1 is shown in Table 21-2 (see page
 
E1-28). It is seen that the increase in average growth rate
 
between Cycles 12 and 13 is negative for three of the four SGs.
 
The increase in average growth rate between Cycles 13 and 14 is
 
positive, but less than 0.1 volts/EFPY, for all four SGs. It may
 
also be noted that SG 3 that had the highest increase in average
 
growth in Cycle 13 had the lowest increase in growth in Cycle 14.
The benchmark cases run for RAI-19 did not add a growth rate adjustment (Delta Volts Adjustment) because the average
 
increase in growth rate was so small. In order to evaluate the
 
impact of a small growth rate adjustment, the prediction for SG 4
 
EOC-14 was recalculated with a growth rate adjustment of
 
0.1 volts/EFPY which bounds the increases in Table 21-2. The
 
comparison of the results reported in Table 19-2 (see page E1-26)
 
and those with the growth rate adjustment is shown in Table 21-3 (see page E1-28). The POB for this case has increased with this
 
adjustment to a conservative prediction relative to the as-found
 
results.
E1-17 Because the average growth rates are small, but variable, the bounding approach to developing the growth rate distribution to
 
be used for predictive analyses is considered appropriate for
 
SQN-2. An approach which will increase the likelihood of a
 
conservative prediction is to add the growth rate adjustment
 
prior to determining the bounding growth rate distribution.
The SQN-2 guidelines for developing growth rates are changed from those given in Section 4-2 (page E4-15). Upon implementation of
 
POPCD, if the average growth rate for any SG shows an increase
 
for the just completed cycle compared to the prior cycle, the
 
incremental increase in average growth per EFPY will be added to
 
each point in the growth rate distribution for that SG.
A bounding curve that envelopes the adjusted growth rate distributions for each SG for the last two cycles is the bounding
 
growth rate distribution to be used for the operational
 
assessment predictions. As discussed in RAI-22, voltage dependent growth (VDG)will be appliedon a SG specific basis for
 
the SGs showing VDG (only when it is conservative) with the
 
bounding growth distribution (determined from SGs without VDG)
 
applied for the other SGs. Similarly, if one SG develops a
 
significantly greater growth rate than the others, a SG specific
 
growth rate distribution will be used for this SG with the
 
bounding growth rate distribution of the other SGs applied to the
 
other SGs. This approach will provide a conservative growth rate
 
distribution, without the excessive conservatism of applying the
 
bounding growth rate adjustment to the bounding growth rate
 
distribution.
NRC Question 22 Please provide a step-by-step description of the rationale that will be used for selecting the growth rate distribution and the
 
POPCD curve used in the EOC projections. Please confirm that
 
this methodology was used in performing the benchmarking
 
analysis. If not, please justify any differences. Please
 
confirm that voltage dependent growth is assessed on a SG basis
 
rather than just a composite of all SGs.
TVA Response The step-by-step process to be applied for developing the growth rate distribution used in EOC projections upon NRC approval for
 
implementing POPCD is given below: 1.Prepare cumulative probability distribution function (CPDF) curves for each SG for each of the last two cycles.
 
When POPCD is applied, then either steps 1a or 1b are
 
applicable:
E1-18a.If the NRC has not approved the extreme growth modeling, then all growth rate data from the last two
 
cycles will be included in the assessment. b.If the NRC has approved the extreme growth modeling, than any growth rates greater than 5 volts/EFPY are to
 
be excluded from these distributions and included in
 
the extreme growth distribution, subject to possible
 
future NRC limitations on the extreme growth methods. 2.For each curve selected from Step 1, analyze the growth curve for signs of VDG. In general, only the last cycle
 
growth rates need to be evaluated for VDG since the prior
 
cycle would have previously been evaluated for VDG. a.Plot the individual growth data on a scatter chart with beginning of cycle (BOC) voltages on the x-axis
 
and voltage growth rates on the y-axis. Perform a
 
simple linear regression on these data. If the slope is
 
greater than about 0.1, then VDG should be considered
 
in the operational assessment projection for the next
 
cycle. If the slope is less than or equal to zero, then there is no evidence of VDG. If the slope is only
 
slightly positive (between 0.0 and 0.1), then
 
engineering judgment should be used to determine if VDG
 
needs to be included in the analyses. Engineering
 
judgment decisions should consider the results of the
 
previous POB and leak rate predictions to determine
 
appropriate actions if underpredictions occur, and
 
should consider the affects of potential preventative plugging below the repair limit. In some cases, it may
 
be necessary to perform POB and leak rate sensitivity


calculations to determine which growth curve is
have expected a large number of data points for the EOC 7 through 12 composite curve and a significantly less number of datapoints for any one cycle (unless a significant number of new indications were identified in EOC 13).
TVA Response As noted in the following paragraph, there is a large difference in the number of data points between EOC-7 to EOC-12 and only EOC-12. However, Table 7 has erroneously entered the POPCD parameters for EOC-8 to EOC-12 for EOC-12 parameters. The Corrected Table 7 is attached (see page E1-24) and shows the correct differences in the number of points as discussed below.
The POPCD plot for EOC-12 in Figure 4 of the submittal is correct.
The number of data points for EOC-7 to EOC-12 (Table 4 of submittal) is 4524 for detection at EOCn and 1869 for no detection at EOCn where the corresponding values for only EOC-12 (Table 6 of submittal) are 1494 and 361. These data represent a large number of data points for the EOC-7 to EOC-12 data and a significantly smaller number of data points for Cycle 12 alone.
NRC Question 18 Please confirm that no adjustment to the voltage growth rate distribution is performed when the average growth rate decreases from one cycle to the next.
TVA Response As noted in Section 4.2, page E4-15 of the POPCD submittal, the incremental increase in average growth rate will be implemented when the average growth rate shows an increase for the just completed cycle. The intent of this statement is that the adjustment is made only when the average growth rate increases from one cycle to the next, and no adjustment is performed when the average growth rate decreases. This is further noted in the step-by-step description of developing growth rates given in the response to RAI-22.
NRC Question 19 In the benchmark analysis, you used the composite POPCD curve from Cycle 7 through 12. This does not appear to be appropriate since some of the data was not present at the time of the inspections (and using future data to predict past trends would normally be expected to provide reasonable results). As a result, please repeat the benchmark analysis with POPCD data E1-11


limiting (voltage dependent or independent). b.For each curve in which VDG is apparent, determine how many growth bins to use and the appropriate breakpoints
available at the time the inspections were performed (use of the latest burst and leakage correlations and actual cycle lengths is acceptable). In addition, this benchmarking should not include the datapoint that exhibited extreme voltage growth since actions were taken to limit the possibility of such extreme voltage growths and inclusion of this datapoint can skew the results. This datapoint should not be included in the beginning of cycle voltage distribution or the growth rate data (i.e., the average growth rate or the distribution of growth rates). As part of this benchmarking analysis, please include an analysis of the EOC 14 inspection data completed in Fall 2006. Please include in this response the database used for assessing the integrity of the tubes, the actual cycle length, and the cycle length assumed in the benchmarking analysis. Lastly, discuss whether there has been any significant preventive plugging of tubes such that the benchmarking analysis (or growth rate distributions) may have been skewed.
TVA Response As discussed in page E4-20 of the submittal, the SQN-2 composite POPCD was used for all prior cycles since the industry POPCD for these cycles (required per Section 3.3, pages E4-10 and E4-11 when inadequate plant specific data are available) is essentially the same as the Sequoyah POPCD. Figure 19-1 (see page E1-33) shows the comparison of the industry Addendum 5 POPCD with the SQN-2 POPCD. It is seen that these two distributions are essentially the same with the larger uncertainties in the SQN-2 POPCD leading to a lower 95 percent POPCD slightly smaller than the industry POPCD below about 0.2 volt and a slightly higher POPCD above about 0.3 volt. Page E4-39, Figure 5 compares the SQN-2 POPCD with the industry POPCD updated to the time of the SQN-2 POPCD submittal. In this case, the lower 95 percent SQN-2 POPCD is in excellent agreement with the industry POPCD. It is noted in Table 7-4 of the January 12, 2007 TVA submittal that there is essentially no change in the industry POPCD data between Addenda 4 and 5. Since the industry POPCDs for Addenda 4 to 6 and the SQN-2 POPCD are essentially the same and burst pressures or leak rates are not sensitive to small changes in POD, there was no need to change the POPCD distribution between the projected EOC-11 to EOC-13 predictions in Table 9, page E4-33.
To numerically demonstrate the negligible influence of small differences in POD, the EOC-13 projections were repeated using the Addendum 5 POPCD. The results are shown in the lower part of Table 19-1 (see page E1-33), where the projected leak rates, number of indications, and maximum volts are essentially unchanged by the change in POPCD. Small differences are seen in the burst probabilities with the SQN-2 POPCD yielding slightly lower burst probabilities, which is likely due to the modest E1-12


by performing piecewise regression analysis in  
increase in the SQN-2 POPCD above about 0.3 volt. For benchmarking, the objective is to demonstrate margins over the as-found conditions. This objective is satisfied by both the SQN-2 and Addendum 5 POPCD distributions. The use of the SQN-2 POPCD is thus more realistic than using the Addendum 5 POPCD since it yields slightly smaller burst probability margins. The Addendum 5 POPCD would be the required benchmarking POD for EOC-13 projections if there were significant differences from the SQN-2 POPCD. The Addenda 4 and 5 industry POPCDs would have been the required POPCD distributions for projecting Cycles 11 and 12, respectively. The negligible differences in burst pressures and leak rates between applying the Addendum 5 POPCD and the SQN-2 Cycles 7-12 POPCD together with the negligible differences in POPCD between Addendum 4 and Cycles 7-12 support the use of the Cycles 7-12 POPCD for all benchmarking analyses in Table 8 of the submittal. The actual cycle length in EFPD is compared to the length of time in the analyses in Table 19-5 (see page E1-27).
EOC-11 used the actual time, and the other cases used the times that were used in the predictions in the respective 90-day reports.
The benchmarking analyses for Cycles 13 and 14 are performed including and not including the one large growth rate of 5.67 volts/effective full power year found for Cycle 12 for a comparison of the resulting POB and leakage. It is appropriate to exclude the large growth rate because of the preventive measures discussed in RAI-4. In this case, the bobbin voltages grew at modest rates from 1.06 volts at EOC-7 to 1.98 volts at EOC-11. The indication was not +Point inspected prior to the large 9.76 volts found at EOC-12. The indication would have been
+Point inspected at EOC-11 based on the preventive repair guideline currently being applied to inspect all bobbin DSI indications greater than 1.7 volts. It is not clear that a
+Point inspection at EOC-11 would have led to a +Point amplitude greater than 1.9 volts that would have required repair. The results are shown at the bottom of Table 19-1 (see page E1-24).
It is seen that exclusion of the high growth rate value reduces the burst probabilities and leak rates although the EOC-13 projections remain conservative compared to the as-found results.
Table 19-2 (see page E1-26) provides the EOC-14 projections and as-found results at EOC-14 for projections with and without the large growth rate found in Cycle 12. The columns in the table identify the ARC burst and leak rate correlations, the growth rate used, and the POPCD used in the analyses. The EOC-14 projections with the large growth rate included are the projections given in Table 9 of the submittal. The projections are based on a Cycle 14 length of 545 days where the actual cycle length was 537.1 days. The observations from the comparison are as follows:
E1-13
: 1)  The number of indications is underpredicted when POPCD is used. The extent of the underprediction is shown in Table 19-3A (see page E1-26).
: 2)  Using POPCD, leakage is conservatively predicted for all SGs. The results using the reduced growth rate are much closer to the as-found results.
: 3)  Using POPCD and the large growth rate due to the large indication at EOC-12, POB is conservatively predicted for all SGs.
: 4)  Using POPCD and the growth rate obtained by ignoring the large indication at EOC-12, POB is conservatively predicted for SGs 1, 2, and 3, and is underpredicted by 1.11 x 10-4 using the reported DSIs. This is an underprediction of one tenth of the value for considering method revision (0.001) in the Diablo Canyon TS as approved by NRC.
Based on these observations, the underprediction of the number of indications was investigated. It was noted that the definition of what would be called a DSI was changed in the EOC-14 inspection from the definition used previously. In EOC-14, a bobbin indication that appeared to be inside diameter (ID), and was either RPC inspected and found to be NDD or was reviewed by history to be unchanged and previously RPC tested as NDD, that indication was considered to be a DSI and included in the indication count and the integrity and leakage analysis. Table 19-3B (see page E1-26) shows what the indication count at EOC 14 would have been if the definition of a DSI were unchanged from EOC-13. This table shows that the underprediction would be significantly less, and within the limits specified (15 percent or 150 indications) in the Diablo Canyon TS as approved by NRC.
The probability of burst and leakage were recomputed for EOC-14 results using the revised indication population. It is seen in Table 19-4 (see page E1-27) that the results are slightly but not significantly more favorable. This is because the probability of burst and leakage are very dependent on the largest indications which were not affected by the revision.
It is expected that this change in definition will result in a one-time step change in the number of indications so the predictions for EOC-16 and beyond will not continue to show this level of underprediction. The projections of record for EOC-15 were made in the 90-day report using the approved POD of 0.6.
Projections are planned to be made for EOC-15 for benchmarking purposes using the approved POPCD prior to EOC-15. It is expected that POPCD may be used for the projections of record from EOC-16 forward.
E1-14


accordance with Section 10.3 of the ARC database
There were only 13 tubes preventively plugged at EOC-12 and EOC-
: 13. These are properly treated as plugged tubes in the benchmark projections and the EOC actuals include the influence of all plugging at the prior EOC. The growth rate from EOCn-1 to EOCn includes the growth for all tubes plugged at EOCn. The growth rate from EOCn to EOCn+1 would not include the growth for any tubes plugged at EOCn.
NRC Question 20 Regarding your continuing assessment of the inspection results, please confirm that an assessment will be performed for any underpredictions in order to assess the probable cause. As currently written, it is not clear to the staff whether the assessments would only be performed when the quantitative criteria listed in Section 7.0 of your submittal are exceeded.
In addition, please confirm that the assessment of the underprediction of the number of indications will include the potential need to increase the number of indications regardless of whether the indications that need to be increased are low or high voltage. Lastly, please confirm that you will provide an update (based on the results of your inspection) to Table 7 for the composite and one-cycle POPCD curve for SQN-2 in your 90-day report.
TVA Response As noted in the first bullet of Section 7.0, page E4-22, an assessment of the probable cause for any underpredictions, including potential corrective actions and potential changes to probability of detection and or growth methodology, will be included in the 90-day report. This assessment is expected to be qualitative and no changes in ARC analysis methods are expected to be immediately implemented in operational assessments. An assessment of the potential need to revise the ARC analysis methods will be performed if the underpredictions in burst probability or leak rate exceed the values given in the second bullet in Section 7.0. This assessment is expected to include quantitative evaluations of proposed changes to the analysis methods that might be immediately implemented in the operational assessment.
As noted in the third bullet of Section 7.0, an assessment will be made of the need to increase the number of predicted low voltage indications if the total number of as-found indications is underestimated by greater the 15 percent or by greater than 150 indications. This guidance is based on the small influence of low voltage indications on burst probability and leak rates.
An underprediction of high voltage indications leading to an underprediction of burst probability or leak rate would lead to E1-15


Addendum 6 (Reference 1). 3.When POPCD is applied, determine the need for a growth rate adjustment (Delta Volts Adjustment) to account for  
the assessments of growth rates and POD required by the first or second bullet of Section 7.0.
TVA will provide an update (based on the results of each inspection) to Table 7 for the composite and one-cycle POPCD curve for SQN-2 in the 90-day report.
NRC Question 21 On page E1-5, you indicate that upon approval of the POPCD methodology the growth rates used in the operational assessments will be obtained as the bounding growth rate of the SGs and the composite average growth over the last two cycles of operation.
Please clarify this statement. For example, is the composite average growth, the composite from all SGs over one cycle (or two cycles)? If the composite is from all SGs, discuss whether it is necessary to assess whether the average growth rate from one SG is increasing at a rate greater than the other SGs (implying that this SG may need a larger increase in the average growth rate than the composite growth rate would suggest).
TVA Response The average growth rates for each SG for the past three cycles are shown in Table 21-1 (see page E1-28). Several observations can be made. First, the average growth rates are small, with one exception below 0.1 volt/EFPY; second, growth rates increase and decrease for each SG; and third, the SG with the largest average growth in one cycle is not the one with the largest average growth in the next cycle. The increase in average growth rate for each SG based on Table 21-1 is shown in Table 21-2 (see page E1-28). It is seen that the increase in average growth rate between Cycles 12 and 13 is negative for three of the four SGs.
The increase in average growth rate between Cycles 13 and 14 is positive, but less than 0.1 volts/EFPY, for all four SGs. It may also be noted that SG 3 that had the highest increase in average growth in Cycle 13 had the lowest increase in growth in Cycle 14.
The benchmark cases run for RAI-19 did not add a growth rate adjustment (Delta Volts Adjustment) because the average increase in growth rate was so small. In order to evaluate the impact of a small growth rate adjustment, the prediction for SG 4 EOC-14 was recalculated with a growth rate adjustment of 0.1 volts/EFPY which bounds the increases in Table 21-2. The comparison of the results reported in Table 19-2 (see page E1-26) and those with the growth rate adjustment is shown in Table 21-3 (see page E1-28). The POB for this case has increased with this adjustment to a conservative prediction relative to the as-found results.
E1-16


potentially increasing growth rates, per the following  
Because the average growth rates are small, but variable, the bounding approach to developing the growth rate distribution to be used for predictive analyses is considered appropriate for SQN-2. An approach which will increase the likelihood of a conservative prediction is to add the growth rate adjustment prior to determining the bounding growth rate distribution.
The SQN-2 guidelines for developing growth rates are changed from those given in Section 4-2 (page E4-15). Upon implementation of POPCD, if the average growth rate for any SG shows an increase for the just completed cycle compared to the prior cycle, the incremental increase in average growth per EFPY will be added to each point in the growth rate distribution for that SG.
A bounding curve that envelopes the adjusted growth rate distributions for each SG for the last two cycles is the bounding growth rate distribution to be used for the operational assessment predictions. As discussed in RAI-22, voltage dependent growth (VDG) will be applied on a SG specific basis for the SGs showing VDG (only when it is conservative) with the bounding growth distribution (determined from SGs without VDG) applied for the other SGs. Similarly, if one SG develops a significantly greater growth rate than the others, a SG specific growth rate distribution will be used for this SG with the bounding growth rate distribution of the other SGs applied to the other SGs. This approach will provide a conservative growth rate distribution, without the excessive conservatism of applying the bounding growth rate adjustment to the bounding growth rate distribution.
NRC Question 22 Please provide a step-by-step description of the rationale that will be used for selecting the growth rate distribution and the POPCD curve used in the EOC projections. Please confirm that this methodology was used in performing the benchmarking analysis. If not, please justify any differences. Please confirm that voltage dependent growth is assessed on a SG basis rather than just a composite of all SGs.
TVA Response The step-by-step process to be applied for developing the growth rate distribution used in EOC projections upon NRC approval for implementing POPCD is given below:
: 1. Prepare cumulative probability distribution function (CPDF) curves for each SG for each of the last two cycles.
When POPCD is applied, then either steps 1a or 1b are applicable:
E1-17
: a. If the NRC has not approved the extreme growth modeling, then all growth rate data from the last two cycles will be included in the assessment.
: b. If the NRC has approved the extreme growth modeling, than any growth rates greater than 5 volts/EFPY are to be excluded from these distributions and included in the extreme growth distribution, subject to possible future NRC limitations on the extreme growth methods.
: 2. For each curve selected from Step 1, analyze the growth curve for signs of VDG. In general, only the last cycle growth rates need to be evaluated for VDG since the prior cycle would have previously been evaluated for VDG.
: a. Plot the individual growth data on a scatter chart with beginning of cycle (BOC) voltages on the x-axis and voltage growth rates on the y-axis. Perform a simple linear regression on these data. If the slope is greater than about 0.1, then VDG should be considered in the operational assessment projection for the next cycle. If the slope is less than or equal to zero, then there is no evidence of VDG. If the slope is only slightly positive (between 0.0 and 0.1), then engineering judgment should be used to determine if VDG needs to be included in the analyses. Engineering judgment decisions should consider the results of the previous POB and leak rate predictions to determine appropriate actions if underpredictions occur, and should consider the affects of potential preventative plugging below the repair limit. In some cases, it may be necessary to perform POB and leak rate sensitivity calculations to determine which growth curve is limiting (voltage dependent or independent).
: b. For each curve in which VDG is apparent, determine how many growth bins to use and the appropriate breakpoints by performing piecewise regression analysis in accordance with Section 10.3 of the ARC database Addendum 6 (Reference 1).
: 3. When POPCD is applied, determine the need for a growth rate adjustment (Delta Volts Adjustment) to account for potentially increasing growth rates, per the following steps:
: a. Determine the average growth rate for each SG. If there is VDG, the average growth rate for each cycle on VDG growth bin should be determined. This process is E1-18


steps:a.Determine the average growth rate for each SG. If there is VDG, the average growth rate for each cycle on  
applied for the last two cycles (Cycles n and n-1).
When determining the average growth rates, it is acceptable to include the negative growth rates (in lieu of setting the negative growth rates to zero).
: b. If an extreme voltage growth rate (greater than 5 volts/EFPY) has occurred during either cycle, it should be included or not included as discussed in Step 1.
: c. If the average Cycle n growth is greater than the average Cycle n-1 growth for any SG or any VDG bin, then the difference should be added to each of the individual growth rates in the growth rate distribution and any VDG distributions for any VDG distribution for that SG if found necessary from Step 2.
: d. If the average Cycle n growth is less than the average Cycle n-1 growth, then no adjustment is performed.
: 4. For SGs that do not show VDG, select a growth curve that bounds all SG curves including the Delta Volts Adjustment for the last two cycles. Since the curve bounds all other growth rates for the last two cycles of operation, it will be the limiting curve relative to projecting leakage and probability of burst for these SGs.
In some cases, however, Step 2 may show that it may be necessary to perform analyses for voltage-dependent growth to determine which growth curve is limiting for an SG. In such cases with VDG, it may also be necessary to perform POB and leak rate sensitivity calculations using the different growth curves to determine which curve is limiting. VDG will be applied on a SG specific basis for the SGs showing VDG (only when it is conservative) and a bounding growth distribution (determined from the SGs without VDG) applied for the other SGs as discussed in 3.c above. Similarly, if one SG develops a significantly greater growth rate than the others, a SG specific growth rate distribution will be used for this SG and the bounding growth rate distribution determined from the other SGs applied to the other SGs. For this guideline, the conservative approach of selecting the limiting growth curve regardless of the number of indications in the SG-specific growth distribution is applied so ARC guidelines on minimum numbers of indications in a growth curve do not need to be applied.
: 5. If multiple calculations are performed using different growth rate distributions or POPCD distributions, then the 90-day report should specify the calculation of record.
E1-19


VDG growth bin should be determined. This process is E1-19 applied for the last two cycles (Cycles n and n-1).
The above steps were considered for developing the growth rates used in the benchmarking analyses. No VDG has been experienced on SQN-2 and the growth rate adjustments are negligible for the benchmark cases run, except as described in RAI-21.
When determining the average growth rates, it is  
Since the SQN-2 POPCD database will satisfy all requirements for applying a plant-specific POPCD at the next inspection, including EOC-14 data in the POPCD database, the multi-cycle SQN-2 POPCD from EOC-7 to the last completed POPCD update (e.g., POPCD for EOC-14 when the EOC-15 inspection is completed) will be used for operational assessment projections of burst probability and SLB leak rate except if significant trends in POPCD occur. In this case, appropriate adjustments will be made to the POPCD to ensure conservative projections continue to be made. The step-by-step process for updating POPCD for operational assessments is only to update the multi-cycle POPCD to include POPCD analyses from the last completed inspection. As discussed in the response to RAI-19, the SQN-2 POPCD through EOC-12 was used for EOCs-11 through EOC-14 projections since there are negligible differences in the industry Addenda 4 to 6 POPCDs and the SQN-2 POPCD through EOC-12.
NRC Question 23 You indicate that you will address POPCD uncertainties by either applying POPCD at the lower 95 percent confidence level or including an uncertainty analysis for POD in the operational assessment (Section 8.0 of your January 12, 2007 letter). Please clarify whether the uncertainty analysis for POD in the operational assessment is equivalent to the uncertainty analysis approved for use at Diablo Canyon (in their approval to use POPCD). If not, please clarify this statement.
In addition, since the POPCD curve is used to calculate the probability of burst under steam line break conditions and the amount of leakage under steam line break conditions, it would appear that an assessment of the adequacy of using the lower 95 percent confidence level to address uncertainty (rather than the Monte Carlo approach approved for use at Diablo Canyon) would be to evaluate the effects of the different approach for modeling uncertainty in the POPCD curves on the structural and leakage integrity of the SG tubes. Please provide this assessment.
Since this is a one-time assessment, please discuss your plans to submit a similar analysis in each of your 90-day reports. In the event that the results using the lower 95 percent confidence level are non-conservative, discuss your plans to use the uncertainty modeling approach approved for Diablo Canyon.
E1-20


acceptable to include the negative growth rates (in  
TVA Response The uncertainty analysis methods applied to obtain the lower 95 percent POD are identical to the uncertainty methods approved for use at Diablo Canyon.
The requested comparison of applying directly the lower 95 percent confidence for the POD with performing the Monte Carlo analysis allowing for variability in the POD and then selection of the 95 percent results should never be necessary and is not included in this RAI response or planned for future 90-day reports. The primary purpose for performing Monte Carlo analyses is to reduce the conservatism in applying individual lower confidence values (deterministic analyses) in the analyses for burst pressures and leak rates. Without this established reduction in conservatism, Monte Carlo calculations would rarely or never be performed. Since the POPCD uncertainties are small due to the large number of data points, the effects of including POPCD uncertainties on burst pressures and leak rates, even at the conservative lower 95 percent POD, are negligible.
In order to illustrate the uncertainties in the SQN-2 POPCD, Figure 23-1 (see page E1-34) shows the POPCD curves for the 50 percent confidence, the 95th percentile lower bound, and the 99th percentile lower bound POPCD for volts greater than 1 volt.
It is seen that the curves are quite close. To assess the effect of these differences on probability of burst and leakage, the SG 4 example case which was run with 1 million trials is rerun with the 50 percent confidence and with the 99-percent lower-bound POPCD curves. The results are shown in Table 23-1 (see page E1-28). It is seen that compared to the 50 percent confidence POPCD, the 95 percent confidence POPCD results in a slight increase in the number of indications, leak rate and POB.
However, compared to the 95 percent confidence POPCD, the 99 percent confidence POPCD results in a small increase in the number of indications, no increase in the leak rate, and a small decrease in the POB. From these results, it is seen that the POPCD uncertainties have a negligible effect on the burst and leakage predictions; and therefore, a refinement in the methodology to include the POPCD uncertainties in the Monte Carlo process is unwarranted.
The Industry POPCD curve presented in Figure 1 and Figure 5 and expanded in Figure 5-1 (see page E1-30) is not the Addendum 5 curve used in the benchmark analyses. The Figure 1 curve is described in the submittal as essentially the same as reported in Addendum 6. Later, Figure 5 curve (the same as Figure 1) is described as industry POPCD updated to the time of the Sequoyah 2 POPCD submittal. The Addendum 5 curve is shown in Figure 19-1, and described as Figure 19-1 shows the comparison of the industry Addendum 5 POPCD with the SQN-2 POPCD. It is seen that E1-21


lieu of setting the negative growth rates to zero). b. If an extreme voltage growth rate (greater than 5 volts/EFPY) has occurred during either cycle, it should
these two distributions are essentially the same with the larger uncertainties in the SQN-2 POPCD leading to a lower 95 percent POPCD slightly smaller than the industry POPCD below about 0.2 volt and a slightly higher POPCD above about 0.3 volt.
 
An expanded view of Figure 19-1 is shown as Figure 19-2 (see page E1-34). Figure 19-2 shows that the POPCD used in the benchmark analyses for 95th percentile Addendum 5 is slightly more conservative than the 95th percentile SQN-2 specific curve. Note that in Table 19-1A, the leakage and number of indications are very slightly more conservative for the Addendum 5 cases indicating that the Addendum 5 curve is a slightly more conservative POPCD.
be included or not included as discussed in Step 1. c. If the average Cycle n growth is greater than the average Cycle n-1 growth for any SG or any VDG bin, then the difference should be added to each of the
 
individual growth rates in the growth rate distribution
 
and any VDG distributions for any VDG distribution for
 
that SG if found necessary from Step 2. d. If the average Cycle n growth is less than the average Cycle n-1 growth, then no adjustment is performed. 4.For SGs that do not show VDG, select a growth curve that bounds all SG curves including the Delta Volts
 
Adjustment for the last two cycles. Since the curve
 
bounds all other growth rates for the last two cycles of
 
operation, it will be the limiting curve relative to
 
projecting leakage and probability of burst for these SGs.
 
In some cases, however, Step 2 may show that it may be
 
necessary to perform analyses for voltage-dependent growth
 
to determine which growth curve is limiting for an SG. In
 
such cases with VDG, it may also be necessary to perform
 
POB and leak rate sensitivity calculations using the
 
different growth curves to determine which curve is limiting.VDG will be applied on a SG specific basis for the SGs showing VDG (only when it is conservative) and a bounding growth distribution (determined from the SGs
 
without VDG) applied for the other SGs as discussed in 3.c
 
above. Similarly, if one SG develops a significantly
 
greater growth rate than the others, a SG specific growth
 
rate distribution will be used for this SG and the
 
bounding growth rate distribution determined from the
 
other SGs applied to the other SGs. For this guideline, the conservative approach of selecting the limiting growth
 
curve regardless of the number of indications in the SG-
 
specific growth distribution is applied so ARC guidelines
 
on minimum numbers of indications in a growth curve do not
 
need to be applied. 5.If multiple calculations are performed using different growth rate distributions or POPCD distributions, then the
 
90-day report should specify the calculation of record.
E1-20 The above steps were considered for developing the growth rates used in the benchmarking analyses. No VDG has been experienced
 
on SQN-2 and the growth rate adjustments are negligible for the
 
benchmark cases run, except as described in RAI-21.
Since the SQN-2 POPCD database will satisfy all requirements for applying a plant-specific POPCD at the next inspection, including
 
EOC-14 data in the POPCD database, the multi-cycle SQN-2 POPCD
 
from EOC-7 to the last completed POPCD update (e.g., POPCD for
 
EOC-14 when the EOC-15 inspection is completed) will be used for
 
operational assessment projections of burst probability and SLB
 
leak rate except if significant trends in POPCD occur. In this
 
case, appropriate adjustments will be made to the POPCD to ensure
 
conservative projections continue to be made. The step-by-step
 
process for updating POPCD for operational assessments is only to
 
update the multi-cycle POPCD to include POPCD analyses from the
 
last completed inspection. As discussed in the response to RAI-
 
19, the SQN-2 POPCD through EOC-12 was used for EOCs-11 through
 
EOC-14 projections since there are negligible differences in the
 
industry Addenda 4 to 6 POPCDs and the SQN-2 POPCD through EOC-
 
12.NRC Question 23 You indicate that you will address POPCD uncertainties by either applying POPCD at the lower 95 percent confidence level or
 
including an uncertainty analysis for POD in the operational
 
assessment (Section 8.0 of your January 12, 2007 letter). Please
 
clarify whether the uncertainty analysis for POD in the
 
operational assessment is equivalent to the uncertainty analysis
 
approved for use at Diablo Canyon (in their approval to use
 
POPCD). If not, please clarify this statement.
In addition, since the POPCD curve is used to calculate the probability of burst under steam line break conditions and the
 
amount of leakage under steam line break conditions, it would
 
appear that an assessment of the adequacy of using the lower 95
 
percent confidence level to address uncertainty (rather than the
 
Monte Carlo approach approved for use at Diablo Canyon) would be
 
to evaluate the effects of the different approach for modeling
 
uncertainty in the POPCD curves on the structural and leakage
 
integrity of the SG tubes. Please provide this assessment.
Since this is a one-time assessment, please discuss your plans to submit a similar analysis in each of your 90-day reports. In the
 
event that the results using the lower 95 percent confidence
 
level are non-conservative, discuss your plans to use the
 
uncertainty modeling approach approved for Diablo Canyon.
E1-21 TVA Response The uncertainty analysis methods applied to obtain the lower 95 percent POD are identical to the uncertainty methods approved for
 
use at Diablo Canyon.
The requested comparison of applying directly the lower 95 percent confidence for the POD with performing the Monte Carlo
 
analysis allowing for variability in the POD and then selection
 
of the 95 percent results should never be necessary and is not
 
included in this RAI response or planned for future 90-day
 
reports. The primary purpose for performing Monte Carlo analyses
 
is to reduce the conservatism in applying individual lower
 
confidence values (deterministic analyses) in the analyses for
 
burst pressures and leak rates. Without this established
 
reduction in conservatism, Monte Carlo calculations would rarely
 
or never be performed. Since the POPCD uncertainties are small
 
due to the large number of data points, the effects of including
 
POPCD uncertainties on burst pressures and leak rates, even at
 
the conservative lower 95 percent POD, are negligible.
In order to illustrate the uncertainties in the SQN-2 POPCD, Figure 23-1 (see page E1-34) shows the POPCD curves for the
 
50 percent confidence, the 95 th percentile lower bound, and the 99 th percentile lower bound POPCD for volts greater than 1 volt.
It is seen that the curves are quite close. To assess the effect
 
of these differences on probability of burst and leakage, the SG
 
4 example case which was run with 1 million trials is rerun with
 
the 50 percent confidence and with the 99-percent lower-bound
 
POPCD curves. The results are shown in Table 23-1 (see page E1-
 
28). It is seen that compared to the 50 percent confidence
 
POPCD, the 95 percent confidence POPCD results in a slight
 
increase in the number of indications, leak rate and POB.
 
However, compared to the 95 percent confidence POPCD, the 99
 
percent confidence POPCD results in a small increase in the
 
number of indications, no increase in the leak rate, and a small
 
decrease in the POB. From these results, it is seen that the
 
POPCD uncertainties have a negligible effect on the burst and
 
leakage predictions; and therefore, a refinement in the
 
methodology to include the POPCD uncertainties in the Monte Carlo
 
process is unwarranted.
The Industry POPCD curve presented in Figure 1 and Figure 5 and expanded in Figure 5-1 (see page E1-30) is not the Addendum 5
 
curve used in the benchmark analyses. The Figure 1 curve is
 
described in the submittal as essentially the same as reported
 
in Addendum 6. Later, Figure 5 curve (the same as Figure 1) is
 
described as industry POPCD updated to the time of the Sequoyah
 
2 POPCD submittal. The Addendum 5 curve is shown in Figure 19-
 
1, and described as Figure 19-1 shows the comparison of the
 
industry Addendum 5 POPCD with the SQN-2 POPCD. It is seen that E1-22 these two distributions are essentially the same with the larger uncertainties in the SQN-2 POPCD leading to a lower 95 percent  
 
POPCD slightly smaller than the industry POPCD below about 0.2  
 
volt and a slightly higher POPCD above about 0.3 volt.
An expanded view of Figure 19-1 is shown as Figure 19-2 (see page E1-34). Figure 19-2 shows that the POPCD used in the benchmark  
 
analyses for 95 th percentile Addendum 5 is slightly more conservative than the 95 th percentile SQN-2 specific curve. Note that in Table 19-1A, the leakage and number of indications are  
 
very slightly more conservative for the Addendum 5 cases  
 
indicating that the Addendum 5 curve is a slightly more  
 
conservative POPCD.
The POB values, because they are so small, are somewhat variable because of the Monte Carlo analysis process.
The POB values, because they are so small, are somewhat variable because of the Monte Carlo analysis process.
Therefore, it is not inconsistent that the slightly lower POPCD curve results in a slightly more conservative result.
Therefore, it is not inconsistent that the slightly lower POPCD curve results in a slightly more conservative result.
Compared to the PWSCC ARC that was implemented for Diablo Canyon, the application of a 95 th percentile POPCD is very different.
Compared to the PWSCC ARC that was implemented for Diablo Canyon, the application of a 95th percentile POPCD is very different.
For example, consider a 3-volt indication and assume the  
For example, consider a 3-volt indication and assume the indication was plugged. As seen in Figure 23-1 (see page E1-34), the mean POPCD is 0.97, and the 95th percentile is 0.96.
A POD of 0.97 in the ARC analysis means that for every 100 Monte Carlo trials of the population in the SG, there will be 3 indications that are to be included in the analysis. If uncertainties are applied (symmetric about the mean), sometimes the POD will be a little higher and sometimes it will be a little lower. At the end of the analysis, the number of 3-volt indications considered will be 3/100 times the number of Monte Carlo trials.
At the 95th percentile level of POPCD, the POD is 0.96 which means that in the ARC analysis there will be 4 indications for every 100 Monte Carlo trials. Since this is constant, at the end of the analysis the number of 3-volt indications considered will be 4/100 times the number of Monte Carlo trials. The more 3-volt indications considered in the analysis, the more likely one will have a greater probability of burst and leakage, and the more frequently a larger number of large indications contribute to the total leakage. Therefore, it is apparent that using the 95th percentile POPCD is conservative compared to using the mean with uncertainties.
Given that the bases for performing Monte Carlo analyses is to reduce projected burst and leak rate results relative to deterministic analyses such as directly applying the lower 95 percent POPCD curve, there are no plans to include sampling of E1-22


indication was plugged. As seen in Figure 23-1 (see page
POPCD uncertainties in operational assessments such as applied for Diablo Canyon.
Supplemental Information Since the submittal was prepared, additional data was obtained from the EOC-14 inspection enabling the construction of POPCD which includes the latest data. This cumulative data is shown in Table 10 (see page E1-38) for the EOC-13 POPCD with data through EOC-14. The log-logistic data fit parameters are given in Table 11 (see page E1-39) and the comparison of the EOC-12 POPCD which has been used in the benchmarks and the EOC-13 POPCD are shown in Figure 25-1 (see page E1-35) with an expanded view in Figure 25-2 (see page E1-36). The EOC-13 POPCD is slightly lower than the EOC-12 POPCD because of the increased number of new indications in EOC-14 due to the change in the DSI definition.
Reference
: 1. EPRI Report NP 7480-L, Addendum 6, 2004 Database Update, Steam Generator Tubing Outside Diameter Stress Corrosion Cracking at Tube Support Plates Database for Alternate Repair Limits, October 2004.
E1-23


E1-34), the mean POPCD is 0.97, and the 95 th percentile is 0.96.
Corrected Table 7. Sequoyah-2 and Industry POPCD Log Logistic Distribution Parameters Parameter                       Sequoyah-2                      Sequoyah-2                   Industry POPCD POPCD                           POPCD                        30 Inspections at EOC-7 to                       At EOC-12 EOC-12 Number of Data 6393                            1845                           46454 Points b0 (Intercept)                         1.9947                         2.3727                             1.9628 b1 (Slope)                           2.9920                         2.6592                             3.1433 V11                          3.530E-03                       1.467E-02                         3.742E-04 V12                          6.826E-03                       2.767E-02                         7.215E-04 V22                          1.728E-02                       6.962E-02                         2.077E-03 Table 19-1 Additions to Table 8. Sequoyah-2 Prior Cycle Benchmarking Results for POPCD Projected  S          Projected Results                 As Found Results         POB & Leak         Growth Rate Used          POD Outage    G    POB        Leak    No. Max.        POB    Leak    No. Max.        Rate                                      Used Rate    Ind. Volts(1)           Rate   Ind. Volts(1) Correlations EOC-13 Projections Reported in Table 8 of POPCD Submittal, 250,000 trials EOC-13     1   1.05x10-3 0.421 342         8.5 1.90x10-5 0.0724 294 1.95 Addendum 5 All SGs: Bounding Cycles 11                Seq.-2
A POD of 0.97 in the ARC analysis means that for every 100 Monte
                      -3 2   1.02x10 0.429 342           8.5 3.10x10-5 0.0769 305 1.97 ¨PSLB = 2405 & 12, Fig. 3-16, Ref. 8                  POPCD
 
                      -3 3  1.23x10 0.574 406           8.7 5.26x10-5 0.224 412 2.36 psi                    including largest growth rate.
Carlo trials of the population in the SG, there will be 3
4   2.78x10-3 1.230 969         8.8 9.24x10-5 0.285 836 1.74 EOC-13 Projections Revised for Changes in Growth Rate and POPCD, 250000 Trials EOC-13     1   9.72x10-5 0.222 342         3.6 1.90x10-5 0.0724 294 1.95 Addendum 5 All SGs: Bounding Cycles 11                Seq.-2
 
                      -5 2   9.72x10     0.240 342     3.6 3.10x10-5 0.0769 305 1.97 ¨PSLB = 2405 & 12, Fig. 3-16, Ref. 8                  POPCD
indications that are to be included in the analysis. If
                      -4 3  1.40x10      0.355 406     3.8 5.26x10-5 0.224 412 2.36 psi                    without largest growth rate.
 
                      -4 4   2.26x10     0.722 969     3.9 9.24x10-5 0.285 836 1.74 EOC-13     1   1.30x10-4 0.220 345         3.6 1.90x10-5 0.0724 294 1.95 Addendum 5 All SGs: Bounding Cycles 11               Add. 5
uncertainties are applied (symmetric about the mean), sometimes
                      -5 2   7.28x10      0.238 345      3.6 3.10x10-5 0.0769 305 1.97 ¨PSLB = 2405 & 12, Fig. 3-16, Ref. 8                 POPCD
 
                      -4 3   2.17x10      0.352 409     3.8 5.26x10-5 0.224 412 2.36 psi                    without largest growth rate.
the POD will be a little higher and sometimes it will be a little
                      -4 4  2.67x10      0.722 978     3.9 9.24x10-5 0.285 836 1.74 Notes:
 
: 1. Voltage where projected tail accumulates to 0.3 ind.
lower. At the end of the analysis, the number of 3-volt
E1-24
 
indications considered will be 3/100 times the number of Monte
 
Carlo trials.
At the 95 th percentile level of POPCD, the POD is 0.96 which means that in the ARC analysis there will be 4 indications for
 
every 100 Monte Carlo trials. Since this is constant, at the
 
end of the analysis the number of 3-volt indications considered
 
will be 4/100 times the number of Monte Carlo trials. The more
 
3-volt indications considered in the analysis, the more likely
 
one will have a greater probability of burst and leakage, and the
 
more frequently a larger number of large indications contribute
 
to the total leakage. Therefore, it is apparent that using the
 
95 th percentile POPCD is conservative compared to using the mean with uncertainties.
Given that the bases for performing Monte Carlo analyses is to reduce projected burst and leak rate results relative to
 
deterministic analyses such as directly applying the lower 95
 
percent POPCD curve, there are no plans to include sampling of E1-23 POPCD uncertainties in operational assessments such as applied for Diablo Canyon.
Supplemental Information Since the submittal was prepared, additional data was obtained from the EOC-14 inspection enabling the construction of POPCD
 
which includes the latest data. This cumulative data is shown in
 
Table 10 (see page E1-38) for the EOC-13 POPCD with data through
 
EOC-14. The log-logistic data fit parameters are given in
 
Table 11 (see page E1-39) and the comparison of the EOC-12 POPCD
 
which has been used in the benchmarks and the EOC-13 POPCD are
 
shown in Figure 25-1 (see page E1-35) with an expanded view in
 
Figure 25-2 (see page E1-36). The EOC-13 POPCD is slightly lower
 
than the EOC-12 POPCD because of the increased number of new
 
indications in EOC-14 due to the change in the DSI definition.
Reference1.EPRI Report NP 7480-L, Addendum 6, 2004 Database Update, Steam Generator Tubing Outside Diameter Stress Corrosion
 
Cracking at Tube Support Plates Database for Alternate
 
Repair Limits, October 2004.
E1-24 Corrected Table 7. Sequoyah-2 and Industry POPCD Log Logistic Distribution Parameters Parameter Sequoyah-2 POPCD at EOC-7 to EOC-12 Sequoyah-2 POPCD At EOC-12 Industry POPCD 30 Inspections Number of Data Points6393 1845 46454 b 0 (Intercept) 1.9947 2.3727 1.9628 b 1 (Slope) 2.9920 2.6592 3.1433 V 113.530E-03 1.467E-02 3.742E-04 V 12 6.826E-03 2.767E-02 7.215E-04 V 22 1.728E-02 6.962E-02 2.077E-03 Table 19-1 Additions to Table 8. Sequoyah-2 Prior Cycle Benchmarking Results for POPCD Projected Results As Found Results ProjectedOutage S GPOB Leak Rate No.Ind.Max. Volts (1)POB Leak Rate No.Ind.Max. Volts (1)POB & Leak Rate CorrelationsGrowth Rate Used POD Used EOC-13 Projections Reported in Table 8 of POPCD Submittal, 250,000 trials EOC-13 1 1.05x10
-30.421 342 8.5 1.90x10
-50.0724294 1.95 2 1.02x10
-3 0.429 342 8.5 3.10x10
-5 0.0769305 1.97 3 1.23x10
-3 0.574 406 8.7 5.26x10
-5 0.224 412 2.36 4 2.78x10
-3 1.230 969 8.8 9.24x10
-5 0.285 836 1.74 Addendum 5 PSLB = 2405 psiAll SGs: Bounding Cycles 11
& 12, Fig. 3-16, Ref. 8
 
including largest growth rate.
Seq.-2 POPCDEOC-13 Projections Revised for Changes in Growth Rate and POPCD, 250000 Trials EOC-13 1 9.72x10
-50.222 342 3.6 1.90x10
-50.07242941.95 2 9.72x10
-5 0.240 342 3.6 3.10x10
-50.07693051.97 3 1.40x10
-4 0.355 406 3.8 5.26x10
-50.224 4122.36 4 2.26x10
-4 0.722 969 3.9 9.24x10
-50.285 8361.74 Addendum 5 PSLB = 2405 psiAll SGs: Bounding Cycles 11
& 12, Fig. 3-16, Ref. 8
 
without largest growth rate.
Seq.-2 POPCDEOC-13 1 1.30x10
-40.220 345 3.6 1.90x10
-50.07242941.95  2 7.28x10
-5 0.238 345 3.6 3.10x10
-50.07693051.97  3 2.17x10
-4 0.352 409 3.8 5.26x10
-50.224 4122.36  4 2.67x10
-4 0.722 978 3.9 9.24x10
-50.285 8361.74 Addendum 5 PSLB = 2405 psiAll SGs: Bounding Cycles 11  
& 12, Fig. 3-16, Ref. 8
 
without largest growth rate.
Add. 5 POPCD Notes:1. Voltage where projected tail accumulates to 0.3 ind.
E1-25 Table 19-1A Additions to Table 8. Sequoyah-2 Prior Cycle Benchmarking Results for Additional Monte Carlo Trials Projected Results As Found Results ProjectedOutage S GPOB Leak Rate No.Ind.Max. Volts (1)POB Leak Rate No.Ind.Max. Volts (1)POB & Leak Rate CorrelationsGrowth Rate Used POD Used EOC-13 Projections Revised for 1 million trials EOC-13 1 8.65x10
-50.218 342 3.6 1.90x10
-50.07242941.95  2 7.33x10
-5 0.236 342 3.6 3.10x10
-50.07693051.97  3 1.32x10
-4 0.348 406 3.8 5.26x10
-50.224 4122.36  4 2.29x10
-4 0.715 969 3.9 9.24x10
-50.285 8361.74 Addendum 5 PSLB = 2405 psiAll SGs: Bounding Cycles 11
& 12, Fig. 3-16, Ref. 8  
 
without largest growth rate.
Seq.-2 POPCDEOC-13 1 7.66x10
-50.220 345 3.6 1.90x10
-50.07242941.95  2 8.10x10
-5 0.236 345 3.6 3.10x10
-50.07693051.97  3 1.57x10
-4 0.352 409 3.8 5.26x10
-50.224 4122.36 4 2.16x10
-4 0.722 978 3.9 9.24x10
-50.285 8361.74 Addendum 5 PSLB = 2405 psiAll SGs: Bounding Cycles 11
& 12, Fig. 3-16, Ref. 8


without largest growth rate.
Table 19-1A Additions to Table 8. Sequoyah-2 Prior Cycle Benchmarking Results for Additional Monte Carlo Trials Projected  S          Projected Results                    As Found Results            POB & Leak          Growth Rate Used        POD Outage    G    POB        Leak    No. Max.        POB          Leak    No. Max.        Rate                                      Used Rate    Ind. Volts(1)                  Rate    Ind. Volts(1) Correlations EOC-13 Projections Revised for 1 million trials EOC-13    1  8.65x10-5    0.218 342      3.6 1.90x10-5 0.0724 294 1.95 Addendum 5                  All SGs: Bounding Cycles 11 Seq.-2 2  7.33x10-5    0.236 342      3.6 3.10x10-5 0.0769 305 1.97 ¨PSLB = 2405                & 12, Fig. 3-16, Ref. 8      POPCD 3  1.32x10-4    0.348 406      3.8 5.26x10-5 0.224 412 2.36 psi                          without largest growth rate.
Add. 5 POPCD Notes:
4  2.29x10-4    0.715 969      3.9 9.24x10-5 0.285 836 1.74 EOC-13    1  7.66x10-5    0.220 345      3.6 1.90x10-5 0.0724 294 1.95 Addendum 5                  All SGs: Bounding Cycles 11 Add. 5 2  8.10x10-5    0.236 345      3.6 3.10x10-5 0.0769 305 1.97 ¨PSLB = 2405                & 12, Fig. 3-16, Ref. 8      POPCD 3  1.57x10-4    0.352 409      3.8 5.26x10-5 0.224 412 2.36 psi                          without largest growth rate.
4  2.16x10-4    0.722 978      3.9 9.24x10-5 0.285 836 1.74 Notes:
: 1. Voltage where projected tail accumulates to 0.3 ind.
: 1. Voltage where projected tail accumulates to 0.3 ind.
Table 19-1B Additions to Table 8. Sequoyah-2 Prior Cycle Comparison of Results for Additional Monte Carlo Trials ProjectedOutage 1 Million trials 250,000 Trials SG POB Seq-2 POPCD POB Add 5 POPCD Difference as % of Seq 2 POPCD POB POB Seq-2 POPCD POB Add 5 POPCD Difference as % of Seq 2 POPCD POB EOC-13 1 8.65x10
Table 19-1B Additions to Table 8. Sequoyah-2 Prior Cycle Comparison of Results for Additional Monte Carlo Trials Projected    SG                  1 Million trials                                 250,000 Trials Outage POB          POB          Difference as      POB              POB         Difference as Seq-2         Add 5         % of Seq 2       Seq-2           Add 5         % of Seq 2 POPCD        POPCD          POPCD POB        POPCD            POPCD          POPCD POB EOC-13         1     8.65x10-5     7.66x10-5           11.4%       9.72x10-5       1.30x10-4     -33.7%
-5 7.66x10-5 11.4% 9.72x10
2     7.33x10-5     8.10x10-5         -10.5%       9.72x10-5       7.28x10-5     25.1%
-5 1.30x10-4-33.7% 2 7.33x10
3     1.32x10-4     1.57x10-4         -18.9%       1.40x10-4       2.17x10-4     -55%
-5 8.10x10-5-10.5% 9.72x10
4     2.29x10-4     2.16x10-4           5.7%       2.26x10-4       2.67x10-4     -18.1%
-5 7.28x10-5 25.1% 3 1.32x10
E1-25
-4 1.57x10-4-18.9% 1.40x10
-4 2.17x10-4 -55% 4 2.29x10
-4 2.16x10-4 5.7% 2.26x10
-4 2.67x10-4 -18.1%
E1-26 Table 19-2 Additions to Table 9. Sequoyah-2 EOC-14 Benchmarking Results for POPCD Projected Outage S GProjected Results As Found Results POB & Leak Rate Correlations Growth Rate Used POD Used  POB Leak Rate No. Ind Max.Volts POB Leak Rate No. Ind. Max.Volts  EOC-14 Projections Reported in Table 9 of POPCD Submittal EOC-14 1 1.73x10
-30.400 401 9.3 8.76x10
-50.108 438 2.36  2 1.80x10
-3 0.409 412 9.3 6.28x10
-5 0.127 507 1.81  3 2.23x10
-3 0.667 531 9.6 1.35x10
-4 0.266 574 2.27  4 4.57x10
-3 1.12 1116 9.6 3.55x10
-4 0.484 1228 4.74 Addendum 6 PSLB = 2405 psi All SGs: Bounding Cycle 12, Fig. 3-16, Ref. 8 including largest growth rate. Sequoyah-2 POPCD EOC-14 Projections Revised for Changes in Growth Rate  EOC-14 1 1.35x10
-40.160 401 3.7 8.76x10
-50.108 438 2.36  2 9.24x10
-5 0.161 412 3.6 6.28x10
-5 0.127 507 1.81  3 2.31x10
-4 0.352 531 4.0 1.35x10
-4 0.266 574 2.27  4 2.44x10
-4 0.509 1116 4.0 3.55x10
-4 0.484 1228 4.74 Addendum 6 PSLB = 2405 psi All SGs: Bounding Cycle 12, Fig. 3-16, Ref. 8 without largest growth rate. Sequoyah-2 POPCD Table 19-3A EOC-14 DSI Indications as Reported in 90 Day Report SG Reported DSI Predictions with POD = 0.6
( 90 Day Report)
Predictions with POPCD (Table 19-2)
Underpredicted by POPCD Percent Underpredicted1 438 489 401 37 8% 2 507 501 412 95 19% 3 574 680 531 43 7% 4 1228 1387 1116 112 9%
Table 19-3B EOC 14 DSI Indications if EOC
-13 Definition of DSI is Used SG Revised DSI  Predictions with POPCD Under/ Over predicted by


POPCD Percent Under/Over
Table 19-2 Additions to Table 9. Sequoyah-2 EOC-14 Benchmarking Results for POPCD Projected S        Projected Results                  As Found Results            POB & Leak    Growth Rate Used      POD Used Outage G                                                                              Rate Correlations POB      Leak  No. Max.      POB        Leak      No. Max.
Rate  Ind Volts                Rate      Ind. Volts EOC-14 Projections Reported in Table 9 of POPCD Submittal EOC-14  1  1.73x10-3  0.400  401  9.3  8.76x10-5    0.108    438      2.36  Addendum 6    All SGs: Bounding      Sequoyah-2  1.80x10-3  0.409  412  9.3  6.28x10-5    0.127    507      1.81  ¨PSLB = 2405  Cycle 12, Fig. 3-16,  2 POPCD 3  2.23x10-3  0.667  531  9.6  1.35x10-4    0.266    574      2.27  psi          Ref. 8 including 4  4.57x10-3    1.12 1116 9.6    3.55x10-4    0.484    1228    4.74                largest growth rate.
EOC-14 Projections Revised for Changes in Growth Rate EOC-14  1  1.35x10-4  0.160  401  3.7  8.76x10-5    0.108    438      2.36  Addendum 6    All SGs: Bounding      Sequoyah-2  9.24x10-5  0.161  412  3.6  6.28x10-5    0.127    507      1.81  ¨PSLB = 2405  Cycle 12, Fig. 3-16,  2 POPCD 3  2.31x10-4  0.352  531  4.0  1.35x10-4    0.266    574      2.27  psi          Ref. 8 without largest 4  2.44x10-4  0.509 1116 4.0    3.55x10-4    0.484    1228    4.74                growth rate.
Table 19-3A EOC-14 DSI Indications as Reported in 90 Day Report SG          Reported      Predictions with        Predictions with      Underpredicted Percent DSI            POD = 0.6                POPCD                  by POPCD            Underpredicted
( 90 Day Report)          (Table 19-2) 1            438            489                      401                    37                  8%
2            507            501                      412                    95                  19%
3            574            680                      531                    43                  7%
4            1228          1387                    1116                  112                  9%
Table 19-3B EOC 14 DSI Indications if EOC-13 Definition of DSI is Used SG          Revised DSI      Predictions with        Under/ Over         Percent POPCD                    predicted by        Under/Over POPCD              predicted 1            403              401                      2 under            <1% under 2            455              412                      33 under            7% under 3            512              531                      19 over            4% over 4            1161              1116                    45 under            4% under E1-26


predicted1 403 401 2 under <1% under 2 455 412 33 under 7% under 3 512 531 19 over 4% over 4 1161 1116 45 under 4% under E1-27 Table 19-4 EOC-14 As Found Results for SG 4 POB Leak RateNo. Ind. Max. Volts EOC-14 As Reported in 90 Day Report 3.55x10-4 0.484 1228 4.74 EOC-14 Revised to EOC 13 Definition of DSI 3.24x10-4 0.451 1161 4.74 Table 19-5 Cycle Length for Benchmark Analyses EOC Number Actual Cycle length, EFPD Analysis Cycle Length, EFPDEOC-11 510.35 510.35 EOC-12 501.6 515 EOC-13 470.9 498 EOC-14 537.1 545 E1-28 Table 21-1 Average Growth Volts/ EFPY        SG Cycle 12 Cycle 13 Cycle 14 1 0.0466 0.0456 0.0736 2 0.0699 0.0191 0.0893 3 0.0326* 0.0851 0.097 4 0.0517 0.0358 0.1179 Average 0.0501* 0.0451 0.1012
Table 19-4 EOC-14 As Found Results for SG 4 POB           Leak Rate        No. Ind.             Max. Volts EOC-14 As Reported in 90 Day Report
* Large growth indication removed Table 21-2 Increase in Average Growth Volts/ EFPY      SG Cy12-13 Cy13-14  1 -0.001 0.028  2 -0.0508 0.0702  3 0.0525 0.0119  4 -0.0159 0.0821  Average -0.005 0.0561 Table 21-3 Effect of Average Growth Addition Projected Outage S GProjected Results As Found Results POB & Leak Rate Correlations Growth Rate Used POD Used  POB Leak Rate No. Ind Max.Volts POB Leak Rate No. Ind. Max.Volts  EOC-14 Projection From Table 19-2 EOC-14 4 2.44x10
        -4 3.55x10           0.484             1228                   4.74 EOC-14 Revised to EOC 13 Definition of DSI 3.24x10-4         0.451             1161                   4.74 Table 19-5 Cycle Length for Benchmark Analyses EOC Number       Actual Cycle       Analysis Cycle Length, length, EFPD      EFPD EOC-11           510.35             510.35 EOC-12           501.6             515 EOC-13           470.9             498 EOC-14           537.1             545 E1-27
-4 0.509 1116 4.0 3.55x10
-4 0.484 1228 4.74 Addendum 6 PSLB = 2405 psi All SGs: Bounding Cycle 12, Fig. 3-16, Ref. 8 without largest


growth rate. Sequoyah-2 POPCD EOC-14 Projection with 0.1V/EFPY adjustment EOC-14 4 3.99x10
Table 21-1 Average Growth Volts/ EFPY SG        Cycle 12          Cycle 13            Cycle 14 1          0.0466            0.0456                0.0736 2          0.0699            0.0191                0.0893 3          0.0326*          0.0851                0.097 4          0.0517            0.0358                0.1179 Average        0.0501*          0.0451                0.1012
-4 0.687 1116 4.1 3.55x10
* Large growth indication removed Table 21-2 Increase in Average Growth Volts/ EFPY SG              Cy12-13              Cy13-14 1                -0.001                0.028 2              -0.0508              0.0702 3                0.0525              0.0119 4              -0.0159              0.0821 Average              -0.005              0.0561 Table 21-3 Effect of Average Growth Addition Projected S      Projected Results                  As Found Results            POB & Leak    Growth Rate Used      POD Used Outage G                                                                            Rate Correlations POB      Leak    No. Max. POB        Leak      No. Max.
-4 0.484 1228 4.74 Addendum 6 PSLB = 2405 psi All SGs: Bounding Cycle 12, Fig. 3-16, Ref. 8 without largest growth rate, with 0.1V/EFPY adjustmentSequoyah-2 POPCD E1-29 Table 23-1 Sensitivity of POPCD Uncertainties on Results 1 Million Trials Projected Outage S GProjected Results As Found Results POB & Leak Rate Correlations Growth Rate Used POD Used   POB Leak Rate No. Ind Max.Volts POB Leak Rate No. Ind. Max.Volts   EOC-13 Projections, 50% CL POPCD EOC-13 4 2.09x10
Rate    Ind Volts              Rate    Ind. Volts EOC-14 Projection From Table 19-2 EOC-14   4 2.44x10-4 0.509  1116   4.3.55x10-4   0.484   1228   4.74     Addendum 6   All SGs: Bounding     Sequoyah-
-40.701 954 3.9 9.24x10
                                                                                &#xa8;PSLB = 2405 Cycle 12, Fig. 3-16,   2 POPCD psi          Ref. 8 without largest growth rate.
-5 0.285 836 1.74 Addendum 5 PSLB = 2405 psi All SGs: Bounding Cycles 11 & 12, Fig.  
EOC-14 Projection with 0.1V/EFPY adjustment EOC-14   4 3.99x10-4  0.687  1116   4.3.55x10-4    0.484    1228  4.74     Addendum All SGs: Bounding     Sequoyah-
                                                                                &#xa8;PSLB = 2405 Cycle 12, Fig. 3-16,  2 POPCD psi          Ref. 8 without largest growth rate, with 0.1V/EFPY adjustment E1-28


3-16, Ref. 8 without  
Table 23-1 Sensitivity of POPCD Uncertainties on Results 1 Million Trials Projected S      Projected Results                  As Found Results          POB & Leak      Growth Rate Used        POD Used Outage G                                                                          Rate Correlations POB      Leak    No. Max. POB        Leak    No. Max.
Rate    Ind  Volts              Rate    Ind. Volts EOC-13 Projections, 50% CL POPCD EOC-13  4 2.09x10-4  0.701  954    3.9  9.24x10-5    0.285    836  1.74 Addendum 5      All SGs: Bounding      Sequoyah-2
                                                                              &#xa8;PSLB = 2405    Cycles 11 & 12, Fig. POPCD, psi            3-16, Ref. 8 without   50%
largest growth rate. confidence EOC-13 Projections, 95% CL POPCD From Figure 19-1A EOC-13  4 2.29x10-4  0.715  969    3.9  9.24x10-5    0.285    836  1.74 Addendum 5      All SGs: Bounding      Sequoyah-2
                                                                              &#xa8;PSLB = 2405  Cycles 11 & 12, Fig. 3- POPCD, 95%
psi            16, Ref. 8 without      lower bound largest growth rate.
EOC-13 Projections, 99% CL POPCD EOC-13  4 2.05x10-4  0.715  975    3.9  9.24x10-5    0.285    836  1.74  Addendum 5      All SGs: Bounding      Sequoyah-2
                                                                              &#xa8;PSLB = 2405    Cycles 11 & 12, Fig. POPCD, psi            3-16, Ref. 8 without    99% lower largest growth rate. bound E1-29


largest growth rate. Sequoyah-2 POPCD, 50%
Figure 5-1. Sequoyah-2 and Industry 7/8 POPCD above 1.0 Volt Comparison of Sequoyah-2 and Industry 7/8" Tubing POPCD Weighted Generalized Linear Model Loglogistic Solution 100%
confidenceEOC-13 Projections, 95% CL POPCD From Figure 19-1A EOC-13 4 2.29x10
Sequoyah-2 POPCD Regression Probability of Detection Sequoyah-2 POPCD at Lower 95%
-4 0.715 969 3.9 9.24x10
Industry 7/8 POPCD Regression Industry POPCD at Lower 95%
-50.285 836 1.74 Addendum 5 PSLB = 2405 psi All SGs: Bounding Cycles 11 & 12, Fig. 3-
90%
80%
1                                                                                             10 Bobbin Amplitude (Volts)
E1-30


16, Ref. 8 without largest growth rate. Sequoyah-2 POPCD, 95%  
Figure 8-1.
Sequoyah 2 EOC-14: RMS Inferred Bobbin Volts from Multiple SAIs 6
Bobbin Volts Inferred fromMultiple SAIs 5.5 5
4.5 4
3.5 3
2.5 2
RMS Inferred Bobbin 1.5                                                            Volts 1                                                            Ideal Equivalent Volts 0.5 0
0      0.5    1    1.5      2    2.5          3      3.5      4      4.5      5 Measured Bobbin Volts Figure 8-2.
Sequoyah Unit 2 EOC-14 Plus Point Volts to Bobbin Volts Correlation 5.00 4.50 2
y = 0.0174x + 1.0398x + 0.9276 4.00 3.50 Bobbin DSI Volts 3.00 2.50 2.00 1.50 1.00 SAI Data (no DNTs)
Mean Regression Line 0.50 Upper 95% Confidence of Mean Poly. (Upper 95% Confidence of Mean) 0.00 0.00                                                  0.50        1.00          1.50          2.00              2.50            3.00              3.50 Plus Point SAI Volts E1-31


lower bound                                                                                  EOC-13 Projections, 99% CL POPCDEOC-13 4 2.05x10
Figure 16-1. POPCD for Sequoyah-2 Cycles 7-12 and Cycle 12 above 1.0 Volt Comparison of Sequoyah-2 EOC 7-12 and EOC 12 POPCD above 1.0 Volt Weighted Generalized Linear Model Loglogistic Solution 100%
-40.715 975 3.9 9.24x10
Sequoyah-2 EOC 7-12 POPCD Sequoyah-2 EOC 12 POPCD Sequoyah-2 EOC 7-12 POPCD at Lower 95%
-50.285 836 1.74 Addendum 5 PSLB = 2405 psi All SGs: Bounding Cycles 11 & 12, Fig.
Probability of Detection Sequoyah-2 EOC 12 POPCD at Lower 95%
90%
80%
1                                                                                                  10 Bobbin Amplitude (Volts)
E1-32


3-16, Ref. 8 without largest growth rate. Sequoyah-2 POPCD, 99% lower
Figure 19-1 Comparison of Generic POPCD for 7/8" Add. 5 & Sequoyah-2 POPCD of Fig. 3 (Weighted Generalized Linear Model Loglogistic Solution - Fractional POD Data Shown for Information Only) 100%
 
POPCD for Addendum 5 Database 90%            POPCD at Lower 95% for Addendum 5 POPCD for Seq. 2, Fig. 3 POPCD for Seq. 2, Fig. 3 Lower 95%
bound E1-30Figure 5-1. Sequoyah-2 and Industry 7/8 POPCD above 1.0 Volt Comparison of Sequoyah-2 and Industry 7/8" Tubing POPCD Weighted Generalized Linear Model Loglogistic Solution 80%90%100%1 10Bobbin Amplitude (Volts)Probability of Detection Sequoyah-2 POPCD RegressionSequoyah-2 POPCD at Lower 95%Industry 7/8 POPCD RegressionIndustry POPCD at Lower 95%
80%
E1-31 Figure 8-1.Sequoyah 2 EOC-14: RMS Inferred Bobbin Volts from Multiple SAIs 00.5 11.5 22.5 33.5 44.5 55.5 600.511.522.533.544.55Measured Bobbin VoltsBobbin Volts Inferred from Multiple SAIsRMS Inferred BobbinVoltsIdeal Equivalent Volts Figure 8-2. Sequoyah Unit 2 EOC-14 Plus Point Volts to Bobbin Volts Correlationy = 0.0174x 2 + 1.0398x + 0.92760.000.501.001.50 2.00 2.503.003.50 4.004.505.000.000.501.001.502.002.503.003.50Plus Point SAI VoltsBobbin DSI VoltsSAI Data (no DNTs) Mean Regression LineUpper 95% Confidence of MeanPoly. (Upper 95% Confidence of Mean)
70%
E1-32Figure 16-1. POPCD for Sequoyah-2 Cycles 7-12 and Cycle 12 above 1.0 Volt Comparison of Sequoyah-2 EOC 7-12 and EOC 12 POPCD above 1.0 Volt Weighted Generalized Linear Model Loglogistic Solution 80%90%100%1 10Bobbin Amplitude (Volts)Probability of Detection Sequoyah-2 EOC 7-12 POPCDSequoyah-2 EOC 12 POPCDSequoyah-2 EOC 7-12 POPCD at Lower 95%Sequoyah-2 EOC 12 POPCD at Lower 95%
Probability of D etection 60%
E1-33 Figure 19-1 Comparison of Generic POPCD for 7/8" Add. 5 & Sequoyah-2 POPCD of Fig. 3(Weighted Generalized Linear Model Loglogistic Solution - Fractional POD Data Shown for Information Only) 0%10%20%30%
50%
40%50%
40%
60%
30%
70%80%90%100%0.010.1110Bobbin Amplitude (Volts)Probability of Detection POPCD for Addendum 5 DatabasePOPCD at Lower 95% for Addendum 5POPCD for Seq. 2, Fig. 3POPCD for Seq. 2, Fig. 3 Lower 95%
E1-34 Figure 19-2 Expanded View of Figure 19-1 Comparison of Sequoyah-2 and ADD 5 7/8" Tubing POPCD Weighted Generalized Linear Model Loglogistic Solution85%86%87%88%
89%90%91%92%93%94%95%96%97%98%99%100%1 10Bobbin Amplitude (Volts)Probability of DetectionSequoyah-2 POPCD RegressionSequoyah-2 POPCD at Lower 95%Add 5 7/8 POPCD RegressionAdd 5 POPCD at Lower 95%
Figure 23-1 E1-35Comparison of 50th, 95th and 99th Percentile Sequoyah 2 POPCD0.900.91 0.92 0.930.940.950.960.970.98 0.99 1.00110100Volts CDF95th Percent LowerBound99th Percent Lower Bound50% confidence Figure 25-1 E1-36Comparison of Sequo yah-2 EOC-12 and EOC-13 POPCD Weighted Generalized Linear Model Loglogistic Solution 0%10%
20%
20%
30%40%50%60%70%
10%
80%
0%
90%100%0.010.1110Bobbin Amplitude (Volts)Probability of DetectionSeq.-2 EOC-12 POPCD RegressionSeq.-2 EOC-12 POPCD at Lower 95%Seq.2 EOC-13 POPCD RegressionSeq.2 EOC-13 POPCD at Lower 95%
0.01                                     0.1                                       1                             10 Bobbin Amplitude (Volts)
Figure 25-2 E1-37Comparison of Sequoyah-2 EOC-12 and EOC-13 POPCD Weighted Generalized Linear Model Loglogistic Solution 85%86%87%88%89%90%91%92%93%94%95%96%97%98%99%100%1 10Bobbin Amplitude (Volts)Probability of Detectio nSeq.-2 EOC-12 POPCD RegressionSeq.-2 EOC-12 POPCD at Lower 95%Seq.2 EOC-13 POPCD RegressionSeq.2 EOC-13 POPCD at Lower 95%
E1-33
E1-38ColumnHIJKExcluded from POPCDBDD / RDDBDD / RDDBDD w/o RPCBDD w/o RPCBDD / RDDPlugged at EOCnBND w/o RPCBDD / RDDBND w/o RPCBDD w/o RPCBND w/o RPCBND / RDDBDD / RNDBDD w/o RPCAll RND AT EOCn+1Volta g eBDD / RDDBND / RDDBDD / RDDBDD w/o RPCBDD w/o RPCPlugged at EOCnBND / RDDBDD / RDDBND / RDDBDD w/o RPCBND / RDDBND / RDDBDD / RNDBDD / RDDAll BND w/o RPCDetectionNoPOPCD forBinBDD w/o RPCBDD / RDDBND / RNDBDD / RDDBND / RNDBDD w/o RPCBND / RNDBND / RDDBDD / RNDBND / RDDat EOCn+1at EOCnDetectionVoltage BinBDD w/o RPCBND / RDDBND / RDDPlugged at EOCnBDD/RND/Plugged at EOCnat EOCnNote (1)0.01-0.1024380.0950.11-0.20711883410.3550.21-0.301476945340.5650.31-0.4012310415420.6580.41-0.509710643830.7350.51-0.60908792820.7570.61-0.70607392020.7850.71-0.80545531030.8430.81-0.9047410770.8420.91-1.0032267570.8241.01-1.1019176280.8631.11-1.2019131230.8511.21-1.30157670.9161.31-1.40144390.8271.41-1.5083760.8601.51-1.6012630.8971.61-1.7012010.9521.71-1.801801.0001.81-1.905201.0001.91-2.001710.8752.01-2.102401.0002.11-2.200101.0002.21-2.300101.0002.31-2.400101.0002.41-2.500201.0002.51-2.600003.21-3.300003.31-3.400101.0003.41-3.500003.51-3.600101.0003.61-3.700009.61-9.700009.71-9.800101.000000000Total809637726370.707Notes: 0 0 0 66 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 3 0 1 1 9 4
6 8 6 10 6 0 0 5
6New EOCn+1 Bobbin NotRPC InspectedInd.Found Only by RP C at E OCn+1 or at EOC n & Plu gged at EOC n(3)EOC nRPC NDD Bobbin Indications (2)Totals for POPCD EvaluationEOC n Bobbin Ind. RPC Confirmed at EOCn+1EOC n Bobbin Ind. Not RPC Inspected at EOCn+1 EOC n Bobbin Ind. Repaired at EOC nNew EOCn+1 Bobbin RPC Confirmed GSequoyah-2 Specific POPCD Data TableDetection at EOC nNo Detection at EOCn (New Indications)BCDE3)  Includes indications at EOCn plugged at EOCn and new indications at EOCn+1, not reported in the bobbin inspection, and found only by RPC inspection of dents, mixed residuals or other reasons for the RPC inspection. 4)  BDD = Bobbin detected indication; BND = Bobbin NDD intersection; RDD = RPC detected indication; RND = RPC NDD intersection2236141)  POPCD for each voltage bin calculated as (Detection at EOCn)/(Detection at EOCn + No Detection at EOCn). By column, POPCD = (A+B+C)/(A+B+C+D+E+F+G).2)  EOCn RPC NDD bobbin indications are treated as new indications per NRC request836545388321 00 00 00 00 00 00 10 00 00 00 00 00Table 10:  Sequoyah-2 Composite POPCD Summary Evaluation for Results for EOC-7 (1996) thru EOC-14 (2006) for POPCD at EOC-6 thru EOC-13 A0403350 F6181111498020667728330050103320251007341018124393844824114971362672541226115104929445410729852552399163522 6210570113251101 118544552014 29301125 1127826 01 00 0118515410 304130 002000 00 00 00 420040 110010 000010 00 00 00 000020 10 000000 0000000010 000000 00 00 00 000000 10 E1-39 Table 11 Sequoyah Unit 2 EOC-13 POPCD                                            Log-Logistic Distribution Parameters Parameter Sequoyah Unit 2 POPCD at EOC-13 Number of Data Points 9014 b 0(intercept)1.8865 b 1(Slope)2.7789 V 11 2.308E-03 V 12 4.489E-03 V 22 1.169E-02 E2-1 ENCLOSURE 2 TENNESSEE VALLEY AUTHORITY (TVA)
SEQUOYAH NUCLEAR PLANT (SQN)
UNIT 2 REFORMATTED TECHNICAL SPECIFICATION (TS) AND BASES PAGE MARKUPS FOR SQN TS CHANGE 06-06, PROBABILITY OF PRIOR CYCLE DETECTION E2-2 ADMINISTRATIVE CONTROLS STEAM GENERATOR (SG) TUBE INSPECTION REPORT (continued)a. The scope of inspections performed on each SG, b. Active degradation mechanisms found, c. Nondestructive examination techniques utilized for each degradation mechanism, d. Location, orientation (if linear), and measured sizes (if available) of service induced indications, e. Number of tubes plugged during the inspection outage for each active degradation mechanism, f. Total number and percentage of tubes plugged to date, g. The results of condition monitoring, including the results of tube pulls and in-situ testing, and h. The effective plugging percentage for all plugging in each SG. 6.9.1.16.2 A report shall be submitted within 90 days after the initial entry into MODE 4 following completion of an inspection performed in accordance with the steam generator program (6.8.4.k) when voltage based alternate repair criteria have been applied. The report shall include information described in Section 6.b of Attachment 1 to NRC Generic Letter 95-05, Voltage-Based Repair Criteria for Westinghouse Steam Generator Tubes Affected by Outside Diameter Stress Corrosion Cracking. 6.9.1.16.3 For implementation of the voltage-based repair criteria for tube support plate (TSP) intersections, notify the staff prior to initial entry into MODE 4 following completion of an inspection performed in accordance with Specification 6.8.4.k, Steam Generator (SG) Program, should any of the following conditions arise: 1) If circumferential crack-like indications are detected at the TSP intersections. 2) If indications are identified that extend beyond the confines of the TSP. 3) If indications are identified at the TSP elevations that are attributable to primary water stress corrosion cracking. 6.9.1.16.4 For implementation of W*, the calculated steam line break leakage from the application of TSP alternate repair criteria and W* inspection methodology shall be submitted within 90 days after the initial entry into MODE 4 following completion of an inspection performed in accordance with Specification 6.8.4.k, Steam Generator (SG) Program. The report will include the number of indications within the tubesheet region, the location of the indications (relative to the bottom of the WEXTEX transition [BWT] and TTS), the orientation (axial, circumferential, skewed, volumetric), the severity of each indication (e.g., near through-wall or not through-wall), the side of the tube from which the indication initiated (inside or outside diameter), and an assessment of whether the results were consistent with expectations with respect to the number of flaws and flaw severity (and if not consistent, a description of the proposed corrective action).
May 22, 2007 SEQUOYAH - UNIT 2 6-14a Amendment No. 305 IN S ERT 1 E2-3 INSERT 16.9.1.16.5 For implementation of the probability of prior cycle detection (POPCD) method, for the voltage-based repair criteria at tube support plate intersections, if the end-of-cycle conditional tube rupture probability for a postulated main steam line break, the projected


primary to secondary leak rate during a postulated main steam line break, or the number of  
Figure 19-2 Expanded View of Figure 19-1 Comparison of Sequoyah-2 and ADD 5 7/8" Tubing POPCD Weighted Generalized Linear Model Loglogistic Solution 100%
99%
98%
97%
96%
Probability of Detection 95%
94%
93%
92%
91%
90%                                                      Sequoyah-2 POPCD Regression 89%                                                      Sequoyah-2 POPCD at Lower 95%
Add 5 7/8 POPCD Regression 88%
Add 5 POPCD at Lower 95%
87%
86%
85%
1                                                                                  10 Bobbin Amplitude (Volts)
Figure 23-1 E1-34


indications are under predicted by the previous cycle operational assessment, the following
Comparison of 50th, 95th and 99th Percentile Sequoyah 2 POPCD 1.00 0.99 0.98                                            95th Percent Lower 0.97                                            Bound 0.96 CDF 99th Percent Lower 0.95 0.94                                            Bound 0.93                                            50% confidence 0.92 0.91 0.90 1            10                  100 Volts Figure 25-1 E1-35


shall be reported to the Commission within 90 days after initial entry into MODE 4 following
Comparison of Sequoyah-2 EOC-12 and EOC-13 POPCD Weighted Generalized Linear Model Loglogistic Solution 100%
Seq.-2 EOC-12 POPCD Regression 90%
Seq.-2 EOC-12 POPCD at Lower 95%
80%
Seq.2 EOC-13 POPCD Regression Seq.2 EOC-13 POPCD at Lower 95%
70%
Probability of Detection 60%
50%
40%
30%
20%
10%
0%
0.01                      0.1                                      1        10 Bobbin Amplitude (Volts)
Figure 25-2 E1-36


completion of inspection performed in accordance with specification 6.8.4.k, Steam
Comparison of Sequoyah-2 EOC-12 and EOC-13 POPCD Weighted Generalized Linear Model Loglogistic Solution 100%
99%
98%
97%
96%
Probability of Detection 95%
94%
93%
92%
91%
90%
Seq.-2 EOC-12 POPCD Regression 89%
Seq.-2 EOC-12 POPCD at Lower 95%
88%
Seq.2 EOC-13 POPCD Regression 87%
Seq.2 EOC-13 POPCD at Lower 95%
86%
85%
1                                                                              10 Bobbin Amplitude (Volts)
E1-37


Generator Program. 1. The assessment of the probable causes for the under prediction, proposed corrective actions, and any recommended changes to probability of detection or growth
Table 10: Sequoyah-2 Composite POPCD Summary Evaluation for Results for EOC-7 (1996) thru EOC-14 (2006) for POPCD at EOC-6 thru EOC-13 Column                    A                              B                                  C                                    D                                E                                    F                              G                        H            I          J      K Sequoyah-2 Specific POPCD Data Table Detection at EOCn                                                                                              No Detection at EOCn (New Indications)
EOCn Bobbin Ind. RPC        EOCn Bobbin Ind. Not RPC                                                  New EOCn+1 Bobbin RPC          New EOCn+1 Bobbin Not RPC Ind. Found Only by RPC at EOCn+1              EOCn RPC NDD Bobbin        Excluded from    Totals for POPCD EOCn Bobbin Ind. Repaired at EOCn                                                                                                          (3)                    (2)
Confirmed at EOCn+1              Inspected at EOCn+1                                                        Confirmed                          Inspected                  or at EOCn & Plugged at EOCn            Indications                POPCD            Evaluation BDD / RDD      BDD / RDD BDD w/o RPC BDD w/o RPC                BDD / RDD        Plugged at EOCn BND w/o RPC            BDD / RDD BND w/o RPC            BDD w/o RPC BND w/o RPC            BND / RDD        BDD / RND      BDD w/o RPC All RND AT EOCn+1 Voltage      BDD / RDD      BND / RDD      BDD / RDD BDD w/o RPC BDD w/o RPC                  Plugged at EOCn        BND / RDD      BDD / RDD      BND / RDD        BDD w/o RPC        BND / RDD      BND / RDD        BDD / RND      BDD / RDD    All BND w/o RPC Detection      No  POPCD for Bin      BDD w/o RPC        BDD / RDD                                                                                BND / RND      BDD / RDD      BND / RND        BDD w/o RPC        BND / RND      BND / RDD        BDD / RND      BND / RDD        at EOCn+1    at EOCn Detection Voltage Bin BDD w/o RPC BND / RDD                                                                                                                                                            BND / RDD      Plugged at EOCn                              BDD/RND/Plugged              at EOCn      (1)
Note at EOCn 0.01-0.10                  0                              4                                    0                                  3                                35                                  0                                0                      2          4          38    0.095 0.11-0.20                  6                              181                                  1                                  11                                330                                  0                                0                      71        188        341    0.355 0.21-0.30                  20                            667                                  7                                  28                                501                                  0                                5                      147        694        534    0.565 0.31-0.40                  25                            1007                                  9                                  38                                498                                  0                                6                      123        1041        542    0.658 0.41-0.50                  34                            1018                                  12                                  43                                332                                  0                                8                      97        1064        383    0.735 0.51-0.60                  44                            824                                  11                                  49                                226                                  1                                6                      90        879        282    0.757 0.61-0.70                  62                            672                                  5                                  41                                151                                  0                              10                      60        739        202    0.785 0.71-0.80                  94                            454                                  5                                  23                                71                                  3                                6                      54        553        103    0.843 0.81-0.90                107                            298                                  5                                  25                                49                                  2                                1                      47        410          77    0.842 0.91-1.00                  99                            163                                  5                                  22                                25                                  1                                9                      32        267          57    0.824 1.01-1.10                105                              70                                  1                                  13                                10                                  1                                4                      19        176          28    0.863 1.11-1.20                  85                              44                                  2                                  9                                6                                    2                                6                      19        131          23    0.851 1.21-1.30                  55                              20                                  1                                  4                                1                                    1                                1                      15          76          7    0.916 1.31-1.40                  30                              11                                  2                                  5                                0                                    1                                3                      14          43          9    0.827 1.41-1.50                  27                              8                                    2                                  6                                0                                    0                                0                      8          37          6    0.860 1.51-1.60                  18                              5                                    3                                  0                                1                                    1                                1                      1          26          3    0.897 1.61-1.70                  15                              4                                    1                                  0                                0                                    1                                0                      1          20          1    0.952 1.71-1.80                  4                              1                                    3                                  0                                0                                    0                                0                      1          8          0    1.000 1.81-1.90                  2                              0                                    0                                  0                                0                                    0                                0                      5          2          0    1.000 1.91-2.00                  4                              2                                    1                                  1                                0                                    0                                0                      1          7          1    0.875 2.01-2.10                  0                              0                                    4                                  0                                0                                    0                                0                      2          4          0    1.000 2.11-2.20                  0                              0                                    1                                  0                                0                                    0                                0                      0          1          0    1.000 2.21-2.30                  0                              0                                    1                                  0                                0                                    0                                0                      0          1          0    1.000 2.31-2.40                  0                              0                                    1                                  0                                0                                    0                                0                      0          1          0    1.000 2.41-2.50                  0                              0                                    2                                  0                                0                                    0                                0                      0          2          0    1.000 2.51-2.60                  0                              0                                    0                                  0                                0                                    0                                0                      0          0          0 3.21-3.30                  0                              0                                    0                                  0                                0                                    0                                0                      0          0          0 3.31-3.40                  0                              0                                    1                                  0                                0                                    0                                0                      0          1          0    1.000 3.41-3.50                  0                              0                                    0                                  0                                0                                    0                                0                      0          0          0 3.51-3.60                  0                              0                                    1                                  0                                0                                    0                                0                      0          1          0    1.000 3.61-3.70                  0                              0                                    0                                  0                                0                                    0                                0                      0          0          0 9.61-9.70                  0                              0                                    0                                  0                                0                                    0                                0                      0          0          0 9.71-9.80                  0                              0                                    1                                  0                                0                                    0                                0                      0          1          0    1.000 0                              0                                    0                                  0                                0                                    0                                0                      0          0          0 0                              0                                    0                                  0                                0                                    0                                0                      0          0          0 Total                  836                            5453                                  88                                321                              2236                                  14                              66                      809        6377        2637    0.707 Notes:
: 1) POPCD for each voltage bin calculated as (Detection at EOCn)/(Detection at EOCn + No Detection at EOCn). By column, POPCD = (A+B+C)/(A+B+C+D+E+F+G).
: 2) EOCn RPC NDD bobbin indications are treated as new indications per NRC request
: 3) Includes indications at EOCn plugged at EOCn and new indications at EOCn+1, not reported in the bobbin inspection, and found only by RPC inspection of dents, mixed residuals or other reasons for the RPC inspection.
: 4) BDD = Bobbin detected indication; BND = Bobbin NDD intersection; RDD = RPC detected indication; RND = RPC NDD intersection E1-38


methodology indicated by potential methods assessments. 2. An assessment of the potential need to revise the alternate repair criteria analysis methods if:  the burst probability is under predicted by more than 0.001 (i.e.,
Table 11 Sequoyah Unit 2 EOC-13 POPCD Log-Logistic Distribution Parameters Parameter                    Sequoyah Unit 2 POPCD at EOC-13 Number of Data Points        9014 b0 (intercept)              1.8865 b1 (Slope)                  2.7789 V11                          2.308E-03 V12                          4.489E-03 V22                          1.169E-02 E1-39
10 percent of the performance criteria) or an order of magnitude; or the leak rate is


under predicted by more than 0.5 gallon per minute (gpm) or an order of magnitude. 3. An assessment of the potential need to increase the number of predicted low voltage indications at the beginning of cycle if the total number of as-found indications in any
ENCLOSURE 2 TENNESSEE VALLEY AUTHORITY (TVA)
SEQUOYAH NUCLEAR PLANT (SQN)
UNIT 2 REFORMATTED TECHNICAL SPECIFICATION (TS) AND BASES PAGE MARKUPS FOR SQN TS CHANGE 06-06, PROBABILITY OF PRIOR CYCLE DETECTION E2-1


SG are underestimated by greater than 15 percent or by greater than 150 indications.
ADMINISTRATIVE CONTROLS STEAM GENERATOR (SG) TUBE INSPECTION REPORT (continued)
E2-4 REACTOR COOLANT SYSTEM BASES where V GR represents the allowance for flaw growth between inspections and V NDE represents the allowance for potential sources of error in the measurement of the bobbin coil voltage. Further discussion of the assumptions
: a. The scope of inspections performed on each SG,
: b. Active degradation mechanisms found,
: c. Nondestructive examination techniques utilized for each degradation mechanism,
: d. Location, orientation (if linear), and measured sizes (if available) of service induced indications,
: e. Number of tubes plugged during the inspection outage for each active degradation mechanism,
: f. Total number and percentage of tubes plugged to date,
: g. The results of condition monitoring, including the results of tube pulls and in-situ testing, and
: h. The effective plugging percentage for all plugging in each SG.
6.9.1.16.2 A report shall be submitted within 90 days after the initial entry into MODE 4 following completion of an inspection performed in accordance with the steam generator program (6.8.4.k) when voltage based alternate repair criteria have been applied. The report shall include information described in Section 6.b of Attachment 1 to NRC Generic Letter 95-05, Voltage-Based Repair Criteria for Westinghouse Steam Generator Tubes Affected by Outside Diameter Stress Corrosion Cracking.
6.9.1.16.3 For implementation of the voltage-based repair criteria for tube support plate (TSP) intersections, notify the staff prior to initial entry into MODE 4 following completion of an inspection performed in accordance with Specification 6.8.4.k, Steam Generator (SG) Program, should any of the following conditions arise:
: 1) If circumferential crack-like indications are detected at the TSP intersections.
: 2) If indications are identified that extend beyond the confines of the TSP.
: 3) If indications are identified at the TSP elevations that are attributable to primary water stress corrosion cracking.
6.9.1.16.4 For implementation of W*, the calculated steam line break leakage from the application of TSP alternate repair criteria and W* inspection methodology shall be submitted within 90 days after the initial entry into MODE 4 following completion of an inspection performed in accordance with Specification 6.8.4.k, Steam Generator (SG) Program. The report will include the number of INSERT 1 indications within the tubesheet region, the location of the indications (relative to the bottom of the WEXTEX transition [BWT] and TTS), the orientation (axial, circumferential, skewed, volumetric), the severity of each indication (e.g., near through-wall or not through-wall), the side of the tube from which the indication initiated (inside or outside diameter), and an assessment of whether the results were consistent with expectations with respect to the number of flaws and flaw severity (and if not consistent, a description of the proposed corrective action).
May 22, 2007 SEQUOYAH - UNIT 2                                  6-14a                                            Amendment No. 305 E2-2


necessary to determine the voltage repair limit are discussed in GL 95-05. The mid-cycle equation of SR 4.4.5.4.a.10.e should only be used during unplanned inspection in which eddy current data is acquired for indications at the tube support plates. SR 4.4.5.5 implements several reporting requirements recommended by GL 95-05 for situations which NRC wants to be notified prior to returning the S/Gs to service. For SR 4.4.5.5.d., Items 3 and 4, indications are applicable only where alternate plugging criteria are being applied.For the purposes of this reporting requirement, leakage and conditional burst probability can be calculated based on the as-found voltage distribution rather than the projected
INSERT 1 6.9.1.16.5 For implementation of the probability of prior cycle detection (POPCD) method, for the voltage-based repair criteria at tube support plate intersections, if the end-of-cycle conditional tube rupture probability for a postulated main steam line break, the projected primary to secondary leak rate during a postulated main steam line break, or the number of indications are under predicted by the previous cycle operational assessment, the following shall be reported to the Commission within 90 days after initial entry into MODE 4 following completion of inspection performed in accordance with specification 6.8.4.k, Steam Generator Program.
: 1. The assessment of the probable causes for the under prediction, proposed corrective actions, and any recommended changes to probability of detection or growth methodology indicated by potential methods assessments.
: 2. An assessment of the potential need to revise the alternate repair criteria analysis methods if: the burst probability is under predicted by more than 0.001 (i.e.,
10 percent of the performance criteria) or an order of magnitude; or the leak rate is under predicted by more than 0.5 gallon per minute (gpm) or an order of magnitude.
: 3. An assessment of the potential need to increase the number of predicted low voltage indications at the beginning of cycle if the total number of as-found indications in any SG are underestimated by greater than 15 percent or by greater than 150 indications.
E2-3


end-of-cycle voltage distribution (refer to GL 95-05 for more information) when it is not practical to complete these  
INSERT 2 REACTOR COOLANT SYSTEM BASES where VGR represents the allowance for flaw growth between inspections and VNDE represents the allowance for potential sources of error in the measurement of the bobbin coil voltage. Further discussion of the assumptions necessary to determine the voltage repair limit are discussed in GL 95-05.
The mid-cycle equation of SR 4.4.5.4.a.10.e should only be used during unplanned inspection in which eddy current data is acquired for indications at the tube support plates.
SR 4.4.5.5 implements several reporting requirements recommended by GL 95-05 for situations which NRC wants to be notified prior to returning the S/Gs to service. For SR 4.4.5.5.d., Items 3 and 4, indications are applicable only where alternate plugging criteria are being applied. For the purposes of this reporting requirement, leakage and conditional burst probability can be calculated based on the as-found voltage distribution rather than the projected end-of-cycle voltage distribution (refer to GL 95-05 for more information) when it is not practical to complete these calculations using the projected EOC voltage distributions prior to returning the S/Gs to service. Note that if leakage and conditional burst probability were calculated using the measured EOC voltage distribution for the purposes of addressing GL Sections 6.a.1 and 6.a.3 reporting criteria, then the results of the projected EOC voltage distribution should be provided per GL Section 6.b(c) criteria.
Wastage-type defects are unlikely with proper chemistry treatment of the secondary coolant. However, even if a defect should develop in service, it will be found during scheduled inservice steam generator tube examinations. Plugging will be required for all tubes with imperfections exceeding the repair limit defined in Surveillance Requirement 4.4.5.4.a. The portion of the tube that the plugging limit does not apply to is the portion of the tube that is not within the RCS pressure boundary (tube end up to the start of the tube-to-tubesheet weld).
The tube end to tube-to-tubesheet weld portion of the tube does not affect structural integrity of the steam generator tubes and therefore indications found in this portion of the tube will be excluded from the Result and Action Required for tube inspections. It is expected that any indications that extend from this region will be detected during the scheduled tube inspections. Steam generator tube inspections of operating plants have demonstrated the capability to reliably detect degradation that has penetrated 20% of the original tube wall thickness.
Tubes experiencing outside diameter stress corrosion cracking within the thickness of the tube support plate are plugged or repaired by the criteria of 4.4.5.4.a.10.
The W* criteria incorporate the guidance provided in WCAP-14797, Revision 2, Generic W* Tube Plugging Criteria for 51 Series Steam Generator Tubesheet Region WEXTEX Expansions. W* length is the length of tubing into the tubesheet below the bottom of the WEXTEX transition (BWT) that precludes tube pullout in the event of a complete circumferential separation of the tube below the W* length. W* distance is the distance from the top of the tubesheet to the bottom of the W* length including the distance from the top of the tubesheet to the BWT and measurement uncertainties.
Indications detected within the W* distance below the top-of-tube sheet (TTS), will be plugged upon detection. Tubes to which WCAP-14797 is applied can experience through-wall degradation up to the limits defined in Revision 2 without increasing the probability of a tube rupture or large leakage event. Tube degradation of any type or extent below W* distance, including a complete circumferential separation of the tube, is acceptable. As applied at Sequoyah Nuclear Plant Unit 2, the W* methodology is used to define the required tube inspection depth into the hot-leg tubesheet, and is not used to permit degradation in the W* distance to remain in service. Thus while primary to secondary leakage in the W* distance need not be postulated, primary to secondary leakage from potential degradation below the W* distance will be assumed for every inservice tube in the bounding steam generator.
May 3, 2005 SEQUOYAH - UNIT 2                                B 3/4 4-3a                    Amendment No. 181, 211, 213, 243, 291 E2-4


calculations using the projected EOC voltage distributions prior to returning the S/Gs to service. Note that if leakage
INSERT 2 For the operational assessment, the Probability of Prior Cycle Detection (POPCD) voltage based probability of detection (POD) method, as described in a September 15, 2006 letter from Westinghouse Electric Company to TVA (LTR-CDME-06-121, Technical Support for Application of Probability of Prior Cycle Detection for Sequoyah Unit 2 Voltage Based Alternate Repair Criteria), is used to determine the beginning of cycle voltage distributions. The POPCD method is an exception to the GL 95-05 guidance that requires the application of a POD of 0.6 to all previous bobbin indications.
 
Approved by NRC letter dated _________________.
and conditional burst probability were calculated using the measured EOC voltage distribution for the purposes of
E2-5
 
addressing GL Sections 6.a.1 and 6.a.3 reporting criteria, then the results of the projected EOC voltage distribution
 
should be provided per GL Section 6.b(c) criteria. Wastage-type defects are unlikely with proper chemistry treatment of the secondary coolant. However, even if a defect should develop in service, it will be found during scheduled inservice steam generator tube
 
examinations. Plugging will be required for all tubes with imperfections exceeding the repair limit defined in
 
Surveillance Requirement 4.4.5.4.a. The portion of the tube that the plugging limit does not apply to is the portion
 
of the tube that is not within the RCS pressure boundary (tube end up to the start of the tube-to-tubesheet weld).
 
The tube end to tube-to-tubesheet weld portion of the tube does not affect structural integrity of the steam generator
 
tubes and therefore indications found in this portion of the tube will be excluded from the Result and Action
 
Required for tube inspections. It is expected that any indications that extend from this region will be detected during
 
the scheduled tube inspections. Steam generator tube inspections of operating plants have demonstrated the
 
capability to reliably detect degradation that has penetrated 20% of the original tube wall thickness. Tubes experiencing outside diameter stress corrosion cracking within the thickness of the tube support plate are plugged or repaired by the criteria of 4.4.5.4.a.10.
The W* criteria incorporate the guidance provided in WCAP-14797, Revision 2, Generic W* Tube Plugging Criteria for 51 Series Steam Generator Tubesheet Region WEXTEX Expansions. W* length is the length of tubing into the tubesheet below the bottom of the WEXTEX transition (BWT) that precludes tube pullout in the event of a complete circumferential separation of the tube below the W* length. W* distance is the distance from the top of the tubesheet to the bottom of the W* length including the distance from the top of the tubesheet to the BWT and measurement uncertainties. Indications detected within the W* distance below the top-of-tube sheet (TTS), will be plugged upondetection. Tubes to which WCAP-14797 is applied can experience through-wall degradation up to the limits defined in Revision 2 without increasing the probability of a tube rupture or large leakage event. Tube degradation of any type or extent below W* distance, including a complete circumferential separation of the tube, is acceptable. As applied at Sequoyah Nuclear Plant Unit 2, the W* methodology is used to define the required tube inspection depthinto the hot-leg tubesheet, and is not used to permit degradation in the W* distance to remain in service. Thus while primary to secondary leakage in the W* distance need not be postulated, primary to secondary leakage from potential degradation below the W* distance will be assumed for every inservice tube in the bounding steam generator.
May 3, 2005 SEQUOYAH - UNIT 2 B 3/4 4-3a Amendment No. 181, 211, 213, 243, 291 INSERT 2 E2-5 INSERT 2 For the operational assessment, the Probability of Prior Cycle Detection (POPCD) voltage based probability of detection (POD) method, as described in a September 15, 2006 letter from Westinghouse Electric Company to TVA (LTR
-CDME-06-121, Technical Support for Application of Probability of Prior Cycle Detection for Sequoyah Unit 2 Voltage Based Alternate Repair Criteria), is used to determine the beginning of cycle voltage distributions. The POPCD method is an exception to the GL 95-05 guidance that requires the application of a POD of 0.6 to all  


previous bobbin indications.
ENCLOSURE 3 TENNESSEE VALLEY AUTHORITY (TVA)
Approved by NRC letter dated _________________.
E3-1 ENCLOSURE 3 TENNESSEE VALLEY AUTHORITY (TVA)
SEQUOYAH NUCLEAR PLANT (SQN)
SEQUOYAH NUCLEAR PLANT (SQN)
UNIT 2 TVA COMMITMENT TVA will revise SQNs steam generator program to incorporate the methodology for implementation of Probability of Prior Cycle  
UNIT 2 TVA COMMITMENT TVA will revise SQNs steam generator program to incorporate the methodology for implementation of Probability of Prior Cycle Detection (POPCD) as described in Enclosure 1 of this submittal.
 
The program revision will be completed within 45 days following NRC approval of the SQN Unit 2 POPCD TS Change 06-06.
Detection (POPCD) as described in Enclosure 1 of this submittal.
E3-1}}
 
The program revision will be completed within 45 days following  
 
NRC approval of the SQN Unit 2 POPCD TS Change 06-06.}}

Latest revision as of 21:37, 14 November 2019

Response to Request for Additional Information (RAI) Regarding Unit 2 Technical Specification Change 06-06, Probability of Prior Cycle Detection (Popcd)
ML080100595
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 01/08/2008
From: James Smith
Tennessee Valley Authority
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
TAC MD4110
Download: ML080100595 (47)


Text

January 8, 2008 10 CFR 50.90 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Gentlemen:

In the Matter of ) Docket No. 50-328 Tennessee Valley Authority )

SEQUOYAH NUCLEAR PLANT (SQN) RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION (RAI) REGARDING UNIT 2 TECHNICAL SPECIFICATION CHANGE 06-06, PROBABILITY OF PRIOR CYCLE DETECTION (POPCD) (TAC NO. MD4110)

Reference:

NRC letter to TVA dated November 20, 2007, Sequoyah Nuclear Plant, Unit 2 - Request for Additional Information Regarding Revised Probability of Prior Cycle Detection Model (TAC No. MD4110)

Enclosed are the TVA responses to the staffs request for additional information from the reference letter. TVAs responses were discussed with your staff during telephone conference calls on November 27 and December 18, 2007. TVAs responses support staff review of the subject TS change for SQN Unit 2. provides the TVA responses to the staffs questions. Enclosure 2 provides reformatted TS pages for TS Change 06-06 that support TVAs response to NRC question No. 1. Please note that the TS pages provided by Enclosure 2 supersede the TS pages previously provided by TVAs January 12, 2007 letter. Enclosure 3 provides a TVA commitment associated with implementation of the subject TS change.

U.S. Nuclear Regulatory Commission Page 2 January 8, 2008 Please direct questions concerning this issue to J. D. Smith at (423) 843-7170.

I declare under penalty of perjury that the foregoing is true and correct. Executed on this - 8th day of January, 2008.

Sincerely, n Manager, Site Licensing and Industry Affairs Enclosures

1. TVA Reponses to NRC's Request for Additional Information
2. Reformatted TS and Bases page markups for TSC 06-06
3. TVA Commitment cc (Enclosures):

Mr. Brendan T. Moroney, Project Manager U.S. Nuclear Regulatory Commission Mail Stop 08G-9a One White Flint North 11555 Rockville Pike Rockville, Maryland 20852-2739 Mr. Lawrence E. Nanney, Director Division of Radiological Health Third Floor L&C Annex 401 Church Street Nashville, Tennessee 37243-1532

ENCLOSURE 1 TENNESSEE VALLEY AUTHORITY (TVA)

SEQUOYAH NUCLEAR PLANT (SQN)

UNIT 2 RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION (RAI) FOR SQN TECHNICAL SPECIFICATION (TS) CHANGE 06-06, PROBABILITY OF PRIOR CYCLE DETECTION (POPCD)

NRC Question 1 Regarding your proposed reporting requirements for implementation of the POPCD methodology, please update your proposal to reflect your new SG technical specification format. In addition, please discuss your plans to clarify when the report would be submitted since as currently written, you would be required to submit a report 90-days after the SGs were returned to service regardless of whether SG tube inspections were performed. For example, you could specify that consistent with Technical Specification 6.9.1.16.1 the report would be submitted 90-days after the initial entry into MODE 4 following completion of an inspection performed in accordance with Specification 6.8.4.k, Steam Generator (SG) Program.

Please note that the discussion in Section 2.0 of Enclosure 1 to your January 12, 2007, submittal does not match the wording in your proposed Technical Specifications in Enclosure 2. The staff assumed that the proposed wording in the Technical Specifications is what you intended to propose.

TVA response of this submittal provides reformatted TS and Bases markup pages that supersede the markups previously provided in TVAs January 12, 2007 submittal. It may be noted that the wording in Section 2.0 of TVAs January 12, 2007, submittal did contain typographical errors that resulted in a mismatch with the wording provided in Enclosure 2. The proposed TS wording provided in Enclosure 2 was the intended wording.

NRC Question 2 Regarding the changes you intend to make to your Bases, the NRC does not have a copy of the Westinghouse letter that is referenced. As a result, it can not comment on whether this change is appropriate. The NRC expects that if the POPCD methodology is approved that it would be implemented consistent E1-1

with the methodology provided to the staff to support its approval. The methodology in the referenced Westinghouse letter may have been modified as a result of responses to the NRC staffs request for additional information. Please discuss your plans to ensure that the Bases reflect the actual POPCD methodology that is approved by the NRC staff.

TVA Response TVA has revised the Bases pages to reflect the actual POPCD methodology approved by the NRC staff. (Note: Enclosure 2 of this submittal contains the Bases page markups with the references that include the NRC letter that approves the POPCD methodology for SQN Unit 2.)

NRC Question 3 On pages E1-5 and E4-14 of Enclosure 1 to your January 12, 2007, submittal, you indicated that if an indication grows by an extreme amount (i.e., an outlier) that you will implement a methodology intended to address this issue. Given the text on these two pages are different, it is not clear whether the methodology would be submitted for NRC approval. Please confirm that this outlier methodology would be submitted for NRC approval prior to implementation. The NRC staff notes that its previous approval of POPCD relied on (1) modifications to the inspection and repair criteria to limit the potential for indications with high voltage growth; (2) other calculations performed by the licensee; and (3) additional reporting requirements that essentially require an assessment if the under predictions were significant (as discussed in the technical specifications).

TVA Response The outlier method would be submitted for NRC approval prior to implementation consistent with page E4-14 of Enclosure 4.

NRC Question 4 On pages E1-5 and E4-15 of Enclosure 1 to your January 12, 2007, submittal, you indicated that you performed rotating probe inspections of bobbin indications greater than 1.5 volts and no indications exceeded the 1.9 volt threshold for preventive repair. Since the actual practices in prior inspections may affect the potential for large voltage growth rates, please discuss whether any indications were preventively repaired as a result of these inspections (i.e., regardless of whether they exceeded the 1.9 volt threshold). If indications were repaired (to address the potential for large voltage growth rates),

E1-2

discuss whether similar practices will be employed in all future inspections.

TVA Response During the end-of-cycles (EOCs) 12 and 13 inspections, 13 indications were preventively plugged at least in part as a result of the rotating pancake coil (RPC) inspection of indications over 1.5 volts. These indications were the largest RPC confirmed indications less than two bobbin volts. During the EOC-14 inspection, the indications above 1 volt were RPC tested.

A small number of tubes (five indications) were preventively plugged. No specific guideline for preventive tube plugging was applied. The considerations for plugging included RPC volts, bobbin growth rates, number of RPC indications, etc.

TVA will continue to review large bobbin voltage, RPC confirmed indications for preventive tube plugging that do not exceed the 1.9-volt RPC volt threshold for repair. The option for preventive tube plugging will continue to be judgmental based on the overall NDE responses.

NRC Question 5 You indicated that the number of high voltage indications in the POPCD database for SQN-2 does not satisfy the minimum requirements specified by the industry. As a result, you compared the SQN-2 database to the industry database. Please discuss what the effect would be on the SQN-2 POPCD curve if the SQN-1 [Sequoyah Nuclear Plant, Unit 1] and SQN-2 POPCD databases were combined. Although there may be differences in the noise levels (e.g., from denting) between the two units, there may be some insights gained on potential performance for higher voltage level indications.

In addition, please provide an enlarged view of the data above 1.0 volt in Figure 5.

Your justification for using the SQN-2 POPCD curve instead of the more limiting of the composite POPCD or SQN-2 POPCD curve is largely qualitative and relies on the small differences between the curves. Since the POPCD curve is used to calculate the probability of burst under steam line break conditions and the amount of leakage under steam line break conditions, it would appear that a more appropriate comparison would be to evaluate the effects of the different POPCD curves on the structural and leakage integrity of the SG tubes. Please provide this assessment.

E1-3

Since this is a one-time assessment, please discuss your plans to submit a similar analysis until a sufficient number of high voltage data points are present at SQN-2. Alternatively, discuss your plans for using the most limiting of the POPCD curves.

TVA Response The large number of dents and high dent voltages at SQN-1 preclude meaningful combination of data from SQN-1 into POPCD for SQN-2. The addition of the SQN-1 data would not contribute meaningful data for application of POPCD and would significantly degrade the SQN-2 POPCD.

An enlarged view above 1.0 volt in Figure 5 is provided as Figure 5-1 (see page E1-30). The SQN-2 POPCD curve at the lower 95 percent is conservative relative to the industry curve while the nominal regression curves are nearly identical. The smaller number of data points in the SQN-2 POPCD data compared to the industry data lead to the larger uncertainties for the SQN-2 POPCD. However, the differences are small and have negligible influence on burst probability and leakage analyses.

The conclusion that small changes in POPCD have a negligible influence on burst and leakage is based on prior experience with POPCD analyses rather than qualitative judgment. See response to RAI-19 for examples of burst and leakage sensitivity to small changes in POPCD. In Table 19-1 (see page E1-24), the probability of burst and leakage are compared for the Addendum 5 POPCD and the SQN-2 POPCD. All other inputs are identical. The computation considered 250,000 Monte Carlo Trials. In both cases, the results are conservative relative to the as-found indications at end of cycle (EOC)-13. Although the probability of burst (POB) values are small, there are significant differences between the POB values computed using the two different POPCD functions. A test was run to determine if this difference was a consequence of the small number of Monte Carlo trials relative to the POB values. Table 19-1A (see page E1-25) shows the comparable results using 1 million Monte Carlo trials.

Table 19-1B (see page E1-25) shows that the percent difference between the POB using the two different POPCD curves is significantly less when a larger number of trials is used. This is because the Monte Carlo results are more reliable when more bursts are predicted. Similarly, it is expected that for cases where the probability of burst is greater, the difference in POB for slightly different POPCD curves will be small.

A sufficient number of high voltage data points to satisfy the criteria for a plant-specific POPCD is expected to be present when the EOC-14 POPCD is evaluated at the EOC-15 inspection. The earliest that POPCD can be implemented is the EOC-15 inspection.

Accordingly, implementation of POPCD on SQN-2 will be based on E1-4

plant specific data with no need to assess the more limiting of the plant specific and industry POPCD distributions.

NRC Question 6 On page E4-6 (1st bullet), you indicate that the end of cycle (EOC) inspection EOCn bobbin voltages are generally based on the inspection records for the EOCn. Please discuss your plans to report (in the 90-day report) any instances in which sizing is based on a reanalysis of the voltages previously reported. The staff notes that detection will always be based on past inspection records (as indicated in the first bullet).

TVA Response In any instance for which sizing is based on a reanalysis of the voltages previously reported, a description of the change and the basis for the change would be discussed in the 90-day report. No reanalyses have been applied to the POPCD data through the EOC-12 evaluations reported in the submittal. The option for reanalysis is included primarily to permit review of a EOCn missed indication with a very high EOCn+1 voltage for use in growth rate assessments.

NRC Question 7 On page E4-6 (2nd bullet), you indicate that the EOCn voltage for new EOCn+1 indications will be based on lookback analyses when the EOCn voltages are not available from the inspection record.

Please clarify when an EOCn voltage would be available for a flaw not reported in EOCn (or should the when in this sentence really be since). In addition (if when is the correct word in this sentence), please discuss why it is acceptable (in this case) not to confirm that the reported EOCn voltage actually corresponds to the flaw reported at EOCn+1.

TVA Response The word when in the sentence should be changed to the word since. The use of the word since will provide improved clarity for the 2nd bullet on page E4-6.

NRC Question 8 On page E4-7, you indicated that data supporting the adequacy of using the square root sum of the squares method for determining the inferred bobbin voltage from multiple rotating probe indications at a tube support plate was provided by another utility (in an August 18, 2004 letter). Since this information E1-5

was specific to this utility, please provide a similar plot demonstrating that the approach is currently adequate for SQN-2 (future assessments will be provided in the 90-day report).

TVA Response Figure 8-1 (see page E1-31) shows the inferred bobbin voltage from multiple +Point indications compared to the measured bobbin voltages. The inferred bobbin volts are obtained as the square root of the sum of squares of the bobbin volts obtained for each

+Point indication from the correlation of bobbin volts to +Point volts. It is seen that the inferred bobbin volts are conservative compared to the measured bobbin volts for nearly all measurements. The conservatism results from the relatively high bobbin volts obtained from the correlation with +Point volts as shown in Figure 8-2 (see page E1-31), which represents the correlation updated to include EOC-14 data. The polynomial fit to the 95 percent confidence on the mean regression line is used to infer the bobbin volts. It is seen that the bobbin volts inferred from the +Point volts is always greater than unity such that the multiple +Point indication correlation leads to bobbin volts greater than 1.5. Figure 8-2 is further discussed in RAI-9.

NRC Question 9 Figure 2 provides a correlation for assigning an inferred bobbin voltage to indications detected only with a rotating probe. A similar curve is provided in Figure 3-13 of your March 20, 2007 letter, which submitted the SQN-2 Cycle 14 90-day SG report.

Please discuss the differences in these curves. Please discuss if there have been significant changes in this correlation with time. If so, discuss whether a composite curve is more appropriate or whether a conservative lower bound to any single cycle data is appropriate. In addition, please confirm that there are no data from axially oriented outside diameter stress corrosion cracking indications not detectable by bobbin (AONDBs) such that an assessment of the adequacy of this correlation can currently be assessed. The staff notes that it appears that the prior practice was to plug AONDBs on detection (page E4-17).

TVA Response Figure 2 applies bobbin voltages inferred from the 95 percent confidence on the mean regression correlation of bobbin with

+Point volts. This is consistent with Section 10.1 of Addendum 6 to the alternate repair criteria (ARC) database (Reference 1) and prior licensed POPCD applications. Figure 3-13 of the 90-day report infers bobbin voltages from the 95 percent prediction E1-6

interval of the correlation, which yields more conservative bobbin voltage predictions.

Figure 8-2 (see page E1-31) shows a revision of the submittals Figure 2 bobbin to +Point volt correlation for SQN-2 EOC-14 data.

The +Point data for this correlation includes the single axial indication (SAI) data from the EOC-14 inspection.

Upon approval for POPCD implementation, the 95 percent confidence on the mean bobbin to +Point voltage correlation will be applied to obtain inferred bobbin voltages consistent with Figure 2 of the transmittal and Figure 8-2 (see page E1-31) of this response.

The adequacy of the correlation cannot be assessed since the prior practice was to plug the indications.

If/once an AONDB becomes detectable by bobbin, a comparison of the actual bobbin voltage to what would be expected based on the inferred bobbin voltage from the prior inspection and typical voltage growth will be included in the 90-day report.

NRC Question 10 On page E4-9, you indicated that if the p-value is greater than 5 percent, you will propose an alternate probability of detection (POD) model and submit the recommendation to the NRC for approval. Given that it may take time for the NRC to review any changes to the POD model, please discuss the model to be used in the interim pending staff review of the alternate model. The NRC staff notes that it previously accepted the use of a default value of 0.6 for POD as an acceptable alternative.

TVA Response A default value of 0.6 for POD would be used as an alternative POD in the event that the p-value for a POPCD analysis is greater than five percent. However, the likelihood of the p-value increasing from less than 2.9 x 10-7 to 0.05 as more data is accumulated in the database is extremely low.

NRC Question 11 On page E4-15, you indicate that an assessment for the onset of voltage dependent growth should be performed and the methods of Reference 1 applied when growth rates show a dependence on the beginning of cycle voltage. Please confirm that this assessment will be performed. In addition, discuss whether there are any differences in the voltage dependent growth methodology discussed in Reference 1 and the methodology approved by the NRC staff in prior POPCD approvals. If there are any differences, please justify them.

E1-7

TVA Response Assessments for the onset of voltage dependent growth (VDG) will be performed and documented in each 90-day report. There are no differences between the VDG methods of Section 10.3 of Reference 1 and the methodology approved by the NRC staff in prior POPCD approvals. It can be noted that Section 10.3 includes examples based on applying the methods to the plant having a previously approved POPCD.

NRC Question 12 On page E4-16, you indicated that a rotating probe (+Point) inspection would be performed for +Point confirmed indications at EOCn that are not detected by bobbin at EOCn+1. Please confirm that this is Note 1 in Table 1 (rather than Note 3 in Table 1 as indicated in the text).

TVA Response It is correct that Note 1 in Table 1 should have been referenced on page E4-16 rather than Note 3.

NRC Question 13 On page E4-17, you indicate that you assign a through-wall depth (i.e., a percent code) to bobbin indications confirmed with a rotating probe to be volumetric indications. Please confirm that this applies only to volumetric wear indications and thinning/wastage indications rather than to volumetric indications attributed to intergranular attack or closely spaced cracks. Please confirm that the voltage based repair criteria are applied to volumetric outside diameter cracking indications (including intergranular attack). If not, please confirm that these indications are plugged on detection.

TVA Response It is correct that depth assignments for volumetric indications are only made for indications attributed to wear and thinning/wastage indications. The voltage based repair criteria are applied to intergranular attack or volumetric interpretations for outside diameter cracking indications.

E1-8

NRC Question 14 On page E4-18, you indicated that no reevaluation was performed of the EOC 9 data for a 2.03 volt indication that was detected at EOC 10. Please confirm that future assessments of POPCD that use previous data will be re-evaluated to determine the voltage of the potentially missed indication. In addition, please discuss what growth rate was assigned to this indication if the previous data were not reviewed (this is important from a benchmarking standpoint).

TVA Response A review of the EOC-10 90-day report showed no 2.03 volt indication at SG 3, R32C17 H01 as stated on page E4-18.

Supporting documentation for that report noted that the 2.03 volt indication at SG 3, R32C17 H01 which was originally reported as a distorted support indication (DSI) was RPC tested and determined to be an ID flaw, and thus it was eliminated from the axial outer-diameter stress corrosion cracking (ODSCC) analysis.

Therefore, no look back to determine an ODSCC growth rate was performed. This information however was not received by the person developing the POPCD. As described on page E4-18, the average growth rate of 0.1 volt was assigned to this indication to obtain a 1.93 volt missed indication at EOC-9, which is the largest undetected indication in the POPCD database. This remains as a small conservatism in the SQN-2 POPCD. The benchmark predictive calculations for EOC-11 in Table 8 consider the 0.1 volt growth rate for this indication. The largest growth in the EOC-11 predictive analysis is 0.7 volts/effective full-power year.

TVA confirms that future assessments of POPCD that use previous data will be reevaluated to determine the voltage of the potentially missed indication.

NRC Question 15 On page E4-18, you indicate the composite POPCD data contains 11 indications found only with a rotating probe (Column F of Table 4) although there were only six occurrences. You further indicate that the rotating probe only detections are counted as missed indications in two successive cycle POPCD evaluations even though they were repaired on detection. Please clarify this discussion. If an indication was initially detected at EOCn+1 and subsequently plugged, it does not appear (to the staff) that the indications should be counted twice based on a review of Table 1.

E1-9

TVA Response When the indication is found only by RPC at Cycle n+1, the indication is included as a missed bobbin indication at Cycle n (e.g., most frequently bobbin no degredation detected [NDD]

indication bobbin NDD intersection [BND] w/o RPC in Table 1) and entered in Column F in Table 4. When Cycle n+2 is completed, the indication is included as a missed bobbin indication at Cycle n+1 (Cycle n BND w/RPC detected [RDD] in Table 1). In most cases, the indication remains bobbin NDD and RPC detected at EOC n+2 (column F of Table 4) although the indication could be a new indication in Column E or D of Table 4. Since these indications were preventively plugged when found at SQN-2, the indication is missed at Cycle n+1 based on BND w/RDD and plugged as shown in Table 2 for Cycle n.

NRC Question 16 Please provide an enlarged view of the data above 1.0 volt in Figure 4. In addition, please discuss what POPCD curve is required to be used in the assessments given that the POD above 1.0 volt for the cycle 12 data is less than the corresponding POD for the composite dataset.

TVA Response Figure 16-1 (see page E1-32) provides the requested data above 1.0 volt from Figure 4 of the transmittal.

On page E4-19 of TVAs January 12, 2007 transmittal, it is noted that the multi-cycle POPCD is considered more appropriate for future operational assessments than any one cycle of POPCD data.

On page E4-23, first bullet, it is noted that differences between the multi-cycle POPCD and the last cycle should be assessed in the 90-day report relative to the potential for significant changes in detection capability. Recognizing the number of data points for any one cycle of POPCD is considered to be too small to control the expected POPCD for the next cycle, if there are significant negative trends in POPCD, appropriate adjustments will be made to POPCD to ensure reliable projections continue to be made. If there are significant negative trends in POPCD, other corrective actions may also be necessary (e.g., chemical cleaning to reduce noise, other actions to reduce noise in the ECT, . . .).

NRC Question 17 Regarding Table 7, please confirm that the number of data points in the POPCD curve for EOC 7 through 12 is only slightly greater than the number of datapoints from EOC 12. Since a number of datapoints should be present from year to year, the staff would E1-10

have expected a large number of data points for the EOC 7 through 12 composite curve and a significantly less number of datapoints for any one cycle (unless a significant number of new indications were identified in EOC 13).

TVA Response As noted in the following paragraph, there is a large difference in the number of data points between EOC-7 to EOC-12 and only EOC-12. However, Table 7 has erroneously entered the POPCD parameters for EOC-8 to EOC-12 for EOC-12 parameters. The Corrected Table 7 is attached (see page E1-24) and shows the correct differences in the number of points as discussed below.

The POPCD plot for EOC-12 in Figure 4 of the submittal is correct.

The number of data points for EOC-7 to EOC-12 (Table 4 of submittal) is 4524 for detection at EOCn and 1869 for no detection at EOCn where the corresponding values for only EOC-12 (Table 6 of submittal) are 1494 and 361. These data represent a large number of data points for the EOC-7 to EOC-12 data and a significantly smaller number of data points for Cycle 12 alone.

NRC Question 18 Please confirm that no adjustment to the voltage growth rate distribution is performed when the average growth rate decreases from one cycle to the next.

TVA Response As noted in Section 4.2, page E4-15 of the POPCD submittal, the incremental increase in average growth rate will be implemented when the average growth rate shows an increase for the just completed cycle. The intent of this statement is that the adjustment is made only when the average growth rate increases from one cycle to the next, and no adjustment is performed when the average growth rate decreases. This is further noted in the step-by-step description of developing growth rates given in the response to RAI-22.

NRC Question 19 In the benchmark analysis, you used the composite POPCD curve from Cycle 7 through 12. This does not appear to be appropriate since some of the data was not present at the time of the inspections (and using future data to predict past trends would normally be expected to provide reasonable results). As a result, please repeat the benchmark analysis with POPCD data E1-11

available at the time the inspections were performed (use of the latest burst and leakage correlations and actual cycle lengths is acceptable). In addition, this benchmarking should not include the datapoint that exhibited extreme voltage growth since actions were taken to limit the possibility of such extreme voltage growths and inclusion of this datapoint can skew the results. This datapoint should not be included in the beginning of cycle voltage distribution or the growth rate data (i.e., the average growth rate or the distribution of growth rates). As part of this benchmarking analysis, please include an analysis of the EOC 14 inspection data completed in Fall 2006. Please include in this response the database used for assessing the integrity of the tubes, the actual cycle length, and the cycle length assumed in the benchmarking analysis. Lastly, discuss whether there has been any significant preventive plugging of tubes such that the benchmarking analysis (or growth rate distributions) may have been skewed.

TVA Response As discussed in page E4-20 of the submittal, the SQN-2 composite POPCD was used for all prior cycles since the industry POPCD for these cycles (required per Section 3.3, pages E4-10 and E4-11 when inadequate plant specific data are available) is essentially the same as the Sequoyah POPCD. Figure 19-1 (see page E1-33) shows the comparison of the industry Addendum 5 POPCD with the SQN-2 POPCD. It is seen that these two distributions are essentially the same with the larger uncertainties in the SQN-2 POPCD leading to a lower 95 percent POPCD slightly smaller than the industry POPCD below about 0.2 volt and a slightly higher POPCD above about 0.3 volt. Page E4-39, Figure 5 compares the SQN-2 POPCD with the industry POPCD updated to the time of the SQN-2 POPCD submittal. In this case, the lower 95 percent SQN-2 POPCD is in excellent agreement with the industry POPCD. It is noted in Table 7-4 of the January 12, 2007 TVA submittal that there is essentially no change in the industry POPCD data between Addenda 4 and 5. Since the industry POPCDs for Addenda 4 to 6 and the SQN-2 POPCD are essentially the same and burst pressures or leak rates are not sensitive to small changes in POD, there was no need to change the POPCD distribution between the projected EOC-11 to EOC-13 predictions in Table 9, page E4-33.

To numerically demonstrate the negligible influence of small differences in POD, the EOC-13 projections were repeated using the Addendum 5 POPCD. The results are shown in the lower part of Table 19-1 (see page E1-33), where the projected leak rates, number of indications, and maximum volts are essentially unchanged by the change in POPCD. Small differences are seen in the burst probabilities with the SQN-2 POPCD yielding slightly lower burst probabilities, which is likely due to the modest E1-12

increase in the SQN-2 POPCD above about 0.3 volt. For benchmarking, the objective is to demonstrate margins over the as-found conditions. This objective is satisfied by both the SQN-2 and Addendum 5 POPCD distributions. The use of the SQN-2 POPCD is thus more realistic than using the Addendum 5 POPCD since it yields slightly smaller burst probability margins. The Addendum 5 POPCD would be the required benchmarking POD for EOC-13 projections if there were significant differences from the SQN-2 POPCD. The Addenda 4 and 5 industry POPCDs would have been the required POPCD distributions for projecting Cycles 11 and 12, respectively. The negligible differences in burst pressures and leak rates between applying the Addendum 5 POPCD and the SQN-2 Cycles 7-12 POPCD together with the negligible differences in POPCD between Addendum 4 and Cycles 7-12 support the use of the Cycles 7-12 POPCD for all benchmarking analyses in Table 8 of the submittal. The actual cycle length in EFPD is compared to the length of time in the analyses in Table 19-5 (see page E1-27).

EOC-11 used the actual time, and the other cases used the times that were used in the predictions in the respective 90-day reports.

The benchmarking analyses for Cycles 13 and 14 are performed including and not including the one large growth rate of 5.67 volts/effective full power year found for Cycle 12 for a comparison of the resulting POB and leakage. It is appropriate to exclude the large growth rate because of the preventive measures discussed in RAI-4. In this case, the bobbin voltages grew at modest rates from 1.06 volts at EOC-7 to 1.98 volts at EOC-11. The indication was not +Point inspected prior to the large 9.76 volts found at EOC-12. The indication would have been

+Point inspected at EOC-11 based on the preventive repair guideline currently being applied to inspect all bobbin DSI indications greater than 1.7 volts. It is not clear that a

+Point inspection at EOC-11 would have led to a +Point amplitude greater than 1.9 volts that would have required repair. The results are shown at the bottom of Table 19-1 (see page E1-24).

It is seen that exclusion of the high growth rate value reduces the burst probabilities and leak rates although the EOC-13 projections remain conservative compared to the as-found results.

Table 19-2 (see page E1-26) provides the EOC-14 projections and as-found results at EOC-14 for projections with and without the large growth rate found in Cycle 12. The columns in the table identify the ARC burst and leak rate correlations, the growth rate used, and the POPCD used in the analyses. The EOC-14 projections with the large growth rate included are the projections given in Table 9 of the submittal. The projections are based on a Cycle 14 length of 545 days where the actual cycle length was 537.1 days. The observations from the comparison are as follows:

E1-13

1) The number of indications is underpredicted when POPCD is used. The extent of the underprediction is shown in Table 19-3A (see page E1-26).
2) Using POPCD, leakage is conservatively predicted for all SGs. The results using the reduced growth rate are much closer to the as-found results.
3) Using POPCD and the large growth rate due to the large indication at EOC-12, POB is conservatively predicted for all SGs.
4) Using POPCD and the growth rate obtained by ignoring the large indication at EOC-12, POB is conservatively predicted for SGs 1, 2, and 3, and is underpredicted by 1.11 x 10-4 using the reported DSIs. This is an underprediction of one tenth of the value for considering method revision (0.001) in the Diablo Canyon TS as approved by NRC.

Based on these observations, the underprediction of the number of indications was investigated. It was noted that the definition of what would be called a DSI was changed in the EOC-14 inspection from the definition used previously. In EOC-14, a bobbin indication that appeared to be inside diameter (ID), and was either RPC inspected and found to be NDD or was reviewed by history to be unchanged and previously RPC tested as NDD, that indication was considered to be a DSI and included in the indication count and the integrity and leakage analysis. Table 19-3B (see page E1-26) shows what the indication count at EOC 14 would have been if the definition of a DSI were unchanged from EOC-13. This table shows that the underprediction would be significantly less, and within the limits specified (15 percent or 150 indications) in the Diablo Canyon TS as approved by NRC.

The probability of burst and leakage were recomputed for EOC-14 results using the revised indication population. It is seen in Table 19-4 (see page E1-27) that the results are slightly but not significantly more favorable. This is because the probability of burst and leakage are very dependent on the largest indications which were not affected by the revision.

It is expected that this change in definition will result in a one-time step change in the number of indications so the predictions for EOC-16 and beyond will not continue to show this level of underprediction. The projections of record for EOC-15 were made in the 90-day report using the approved POD of 0.6.

Projections are planned to be made for EOC-15 for benchmarking purposes using the approved POPCD prior to EOC-15. It is expected that POPCD may be used for the projections of record from EOC-16 forward.

E1-14

There were only 13 tubes preventively plugged at EOC-12 and EOC-

13. These are properly treated as plugged tubes in the benchmark projections and the EOC actuals include the influence of all plugging at the prior EOC. The growth rate from EOCn-1 to EOCn includes the growth for all tubes plugged at EOCn. The growth rate from EOCn to EOCn+1 would not include the growth for any tubes plugged at EOCn.

NRC Question 20 Regarding your continuing assessment of the inspection results, please confirm that an assessment will be performed for any underpredictions in order to assess the probable cause. As currently written, it is not clear to the staff whether the assessments would only be performed when the quantitative criteria listed in Section 7.0 of your submittal are exceeded.

In addition, please confirm that the assessment of the underprediction of the number of indications will include the potential need to increase the number of indications regardless of whether the indications that need to be increased are low or high voltage. Lastly, please confirm that you will provide an update (based on the results of your inspection) to Table 7 for the composite and one-cycle POPCD curve for SQN-2 in your 90-day report.

TVA Response As noted in the first bullet of Section 7.0, page E4-22, an assessment of the probable cause for any underpredictions, including potential corrective actions and potential changes to probability of detection and or growth methodology, will be included in the 90-day report. This assessment is expected to be qualitative and no changes in ARC analysis methods are expected to be immediately implemented in operational assessments. An assessment of the potential need to revise the ARC analysis methods will be performed if the underpredictions in burst probability or leak rate exceed the values given in the second bullet in Section 7.0. This assessment is expected to include quantitative evaluations of proposed changes to the analysis methods that might be immediately implemented in the operational assessment.

As noted in the third bullet of Section 7.0, an assessment will be made of the need to increase the number of predicted low voltage indications if the total number of as-found indications is underestimated by greater the 15 percent or by greater than 150 indications. This guidance is based on the small influence of low voltage indications on burst probability and leak rates.

An underprediction of high voltage indications leading to an underprediction of burst probability or leak rate would lead to E1-15

the assessments of growth rates and POD required by the first or second bullet of Section 7.0.

TVA will provide an update (based on the results of each inspection) to Table 7 for the composite and one-cycle POPCD curve for SQN-2 in the 90-day report.

NRC Question 21 On page E1-5, you indicate that upon approval of the POPCD methodology the growth rates used in the operational assessments will be obtained as the bounding growth rate of the SGs and the composite average growth over the last two cycles of operation.

Please clarify this statement. For example, is the composite average growth, the composite from all SGs over one cycle (or two cycles)? If the composite is from all SGs, discuss whether it is necessary to assess whether the average growth rate from one SG is increasing at a rate greater than the other SGs (implying that this SG may need a larger increase in the average growth rate than the composite growth rate would suggest).

TVA Response The average growth rates for each SG for the past three cycles are shown in Table 21-1 (see page E1-28). Several observations can be made. First, the average growth rates are small, with one exception below 0.1 volt/EFPY; second, growth rates increase and decrease for each SG; and third, the SG with the largest average growth in one cycle is not the one with the largest average growth in the next cycle. The increase in average growth rate for each SG based on Table 21-1 is shown in Table 21-2 (see page E1-28). It is seen that the increase in average growth rate between Cycles 12 and 13 is negative for three of the four SGs.

The increase in average growth rate between Cycles 13 and 14 is positive, but less than 0.1 volts/EFPY, for all four SGs. It may also be noted that SG 3 that had the highest increase in average growth in Cycle 13 had the lowest increase in growth in Cycle 14.

The benchmark cases run for RAI-19 did not add a growth rate adjustment (Delta Volts Adjustment) because the average increase in growth rate was so small. In order to evaluate the impact of a small growth rate adjustment, the prediction for SG 4 EOC-14 was recalculated with a growth rate adjustment of 0.1 volts/EFPY which bounds the increases in Table 21-2. The comparison of the results reported in Table 19-2 (see page E1-26) and those with the growth rate adjustment is shown in Table 21-3 (see page E1-28). The POB for this case has increased with this adjustment to a conservative prediction relative to the as-found results.

E1-16

Because the average growth rates are small, but variable, the bounding approach to developing the growth rate distribution to be used for predictive analyses is considered appropriate for SQN-2. An approach which will increase the likelihood of a conservative prediction is to add the growth rate adjustment prior to determining the bounding growth rate distribution.

The SQN-2 guidelines for developing growth rates are changed from those given in Section 4-2 (page E4-15). Upon implementation of POPCD, if the average growth rate for any SG shows an increase for the just completed cycle compared to the prior cycle, the incremental increase in average growth per EFPY will be added to each point in the growth rate distribution for that SG.

A bounding curve that envelopes the adjusted growth rate distributions for each SG for the last two cycles is the bounding growth rate distribution to be used for the operational assessment predictions. As discussed in RAI-22, voltage dependent growth (VDG) will be applied on a SG specific basis for the SGs showing VDG (only when it is conservative) with the bounding growth distribution (determined from SGs without VDG) applied for the other SGs. Similarly, if one SG develops a significantly greater growth rate than the others, a SG specific growth rate distribution will be used for this SG with the bounding growth rate distribution of the other SGs applied to the other SGs. This approach will provide a conservative growth rate distribution, without the excessive conservatism of applying the bounding growth rate adjustment to the bounding growth rate distribution.

NRC Question 22 Please provide a step-by-step description of the rationale that will be used for selecting the growth rate distribution and the POPCD curve used in the EOC projections. Please confirm that this methodology was used in performing the benchmarking analysis. If not, please justify any differences. Please confirm that voltage dependent growth is assessed on a SG basis rather than just a composite of all SGs.

TVA Response The step-by-step process to be applied for developing the growth rate distribution used in EOC projections upon NRC approval for implementing POPCD is given below:

1. Prepare cumulative probability distribution function (CPDF) curves for each SG for each of the last two cycles.

When POPCD is applied, then either steps 1a or 1b are applicable:

E1-17

a. If the NRC has not approved the extreme growth modeling, then all growth rate data from the last two cycles will be included in the assessment.
b. If the NRC has approved the extreme growth modeling, than any growth rates greater than 5 volts/EFPY are to be excluded from these distributions and included in the extreme growth distribution, subject to possible future NRC limitations on the extreme growth methods.
2. For each curve selected from Step 1, analyze the growth curve for signs of VDG. In general, only the last cycle growth rates need to be evaluated for VDG since the prior cycle would have previously been evaluated for VDG.
a. Plot the individual growth data on a scatter chart with beginning of cycle (BOC) voltages on the x-axis and voltage growth rates on the y-axis. Perform a simple linear regression on these data. If the slope is greater than about 0.1, then VDG should be considered in the operational assessment projection for the next cycle. If the slope is less than or equal to zero, then there is no evidence of VDG. If the slope is only slightly positive (between 0.0 and 0.1), then engineering judgment should be used to determine if VDG needs to be included in the analyses. Engineering judgment decisions should consider the results of the previous POB and leak rate predictions to determine appropriate actions if underpredictions occur, and should consider the affects of potential preventative plugging below the repair limit. In some cases, it may be necessary to perform POB and leak rate sensitivity calculations to determine which growth curve is limiting (voltage dependent or independent).
b. For each curve in which VDG is apparent, determine how many growth bins to use and the appropriate breakpoints by performing piecewise regression analysis in accordance with Section 10.3 of the ARC database Addendum 6 (Reference 1).
3. When POPCD is applied, determine the need for a growth rate adjustment (Delta Volts Adjustment) to account for potentially increasing growth rates, per the following steps:
a. Determine the average growth rate for each SG. If there is VDG, the average growth rate for each cycle on VDG growth bin should be determined. This process is E1-18

applied for the last two cycles (Cycles n and n-1).

When determining the average growth rates, it is acceptable to include the negative growth rates (in lieu of setting the negative growth rates to zero).

b. If an extreme voltage growth rate (greater than 5 volts/EFPY) has occurred during either cycle, it should be included or not included as discussed in Step 1.
c. If the average Cycle n growth is greater than the average Cycle n-1 growth for any SG or any VDG bin, then the difference should be added to each of the individual growth rates in the growth rate distribution and any VDG distributions for any VDG distribution for that SG if found necessary from Step 2.
d. If the average Cycle n growth is less than the average Cycle n-1 growth, then no adjustment is performed.
4. For SGs that do not show VDG, select a growth curve that bounds all SG curves including the Delta Volts Adjustment for the last two cycles. Since the curve bounds all other growth rates for the last two cycles of operation, it will be the limiting curve relative to projecting leakage and probability of burst for these SGs.

In some cases, however, Step 2 may show that it may be necessary to perform analyses for voltage-dependent growth to determine which growth curve is limiting for an SG. In such cases with VDG, it may also be necessary to perform POB and leak rate sensitivity calculations using the different growth curves to determine which curve is limiting. VDG will be applied on a SG specific basis for the SGs showing VDG (only when it is conservative) and a bounding growth distribution (determined from the SGs without VDG) applied for the other SGs as discussed in 3.c above. Similarly, if one SG develops a significantly greater growth rate than the others, a SG specific growth rate distribution will be used for this SG and the bounding growth rate distribution determined from the other SGs applied to the other SGs. For this guideline, the conservative approach of selecting the limiting growth curve regardless of the number of indications in the SG-specific growth distribution is applied so ARC guidelines on minimum numbers of indications in a growth curve do not need to be applied.

5. If multiple calculations are performed using different growth rate distributions or POPCD distributions, then the 90-day report should specify the calculation of record.

E1-19

The above steps were considered for developing the growth rates used in the benchmarking analyses. No VDG has been experienced on SQN-2 and the growth rate adjustments are negligible for the benchmark cases run, except as described in RAI-21.

Since the SQN-2 POPCD database will satisfy all requirements for applying a plant-specific POPCD at the next inspection, including EOC-14 data in the POPCD database, the multi-cycle SQN-2 POPCD from EOC-7 to the last completed POPCD update (e.g., POPCD for EOC-14 when the EOC-15 inspection is completed) will be used for operational assessment projections of burst probability and SLB leak rate except if significant trends in POPCD occur. In this case, appropriate adjustments will be made to the POPCD to ensure conservative projections continue to be made. The step-by-step process for updating POPCD for operational assessments is only to update the multi-cycle POPCD to include POPCD analyses from the last completed inspection. As discussed in the response to RAI-19, the SQN-2 POPCD through EOC-12 was used for EOCs-11 through EOC-14 projections since there are negligible differences in the industry Addenda 4 to 6 POPCDs and the SQN-2 POPCD through EOC-12.

NRC Question 23 You indicate that you will address POPCD uncertainties by either applying POPCD at the lower 95 percent confidence level or including an uncertainty analysis for POD in the operational assessment (Section 8.0 of your January 12, 2007 letter). Please clarify whether the uncertainty analysis for POD in the operational assessment is equivalent to the uncertainty analysis approved for use at Diablo Canyon (in their approval to use POPCD). If not, please clarify this statement.

In addition, since the POPCD curve is used to calculate the probability of burst under steam line break conditions and the amount of leakage under steam line break conditions, it would appear that an assessment of the adequacy of using the lower 95 percent confidence level to address uncertainty (rather than the Monte Carlo approach approved for use at Diablo Canyon) would be to evaluate the effects of the different approach for modeling uncertainty in the POPCD curves on the structural and leakage integrity of the SG tubes. Please provide this assessment.

Since this is a one-time assessment, please discuss your plans to submit a similar analysis in each of your 90-day reports. In the event that the results using the lower 95 percent confidence level are non-conservative, discuss your plans to use the uncertainty modeling approach approved for Diablo Canyon.

E1-20

TVA Response The uncertainty analysis methods applied to obtain the lower 95 percent POD are identical to the uncertainty methods approved for use at Diablo Canyon.

The requested comparison of applying directly the lower 95 percent confidence for the POD with performing the Monte Carlo analysis allowing for variability in the POD and then selection of the 95 percent results should never be necessary and is not included in this RAI response or planned for future 90-day reports. The primary purpose for performing Monte Carlo analyses is to reduce the conservatism in applying individual lower confidence values (deterministic analyses) in the analyses for burst pressures and leak rates. Without this established reduction in conservatism, Monte Carlo calculations would rarely or never be performed. Since the POPCD uncertainties are small due to the large number of data points, the effects of including POPCD uncertainties on burst pressures and leak rates, even at the conservative lower 95 percent POD, are negligible.

In order to illustrate the uncertainties in the SQN-2 POPCD, Figure 23-1 (see page E1-34) shows the POPCD curves for the 50 percent confidence, the 95th percentile lower bound, and the 99th percentile lower bound POPCD for volts greater than 1 volt.

It is seen that the curves are quite close. To assess the effect of these differences on probability of burst and leakage, the SG 4 example case which was run with 1 million trials is rerun with the 50 percent confidence and with the 99-percent lower-bound POPCD curves. The results are shown in Table 23-1 (see page E1-28). It is seen that compared to the 50 percent confidence POPCD, the 95 percent confidence POPCD results in a slight increase in the number of indications, leak rate and POB.

However, compared to the 95 percent confidence POPCD, the 99 percent confidence POPCD results in a small increase in the number of indications, no increase in the leak rate, and a small decrease in the POB. From these results, it is seen that the POPCD uncertainties have a negligible effect on the burst and leakage predictions; and therefore, a refinement in the methodology to include the POPCD uncertainties in the Monte Carlo process is unwarranted.

The Industry POPCD curve presented in Figure 1 and Figure 5 and expanded in Figure 5-1 (see page E1-30) is not the Addendum 5 curve used in the benchmark analyses. The Figure 1 curve is described in the submittal as essentially the same as reported in Addendum 6. Later, Figure 5 curve (the same as Figure 1) is described as industry POPCD updated to the time of the Sequoyah 2 POPCD submittal. The Addendum 5 curve is shown in Figure 19-1, and described as Figure 19-1 shows the comparison of the industry Addendum 5 POPCD with the SQN-2 POPCD. It is seen that E1-21

these two distributions are essentially the same with the larger uncertainties in the SQN-2 POPCD leading to a lower 95 percent POPCD slightly smaller than the industry POPCD below about 0.2 volt and a slightly higher POPCD above about 0.3 volt.

An expanded view of Figure 19-1 is shown as Figure 19-2 (see page E1-34). Figure 19-2 shows that the POPCD used in the benchmark analyses for 95th percentile Addendum 5 is slightly more conservative than the 95th percentile SQN-2 specific curve. Note that in Table 19-1A, the leakage and number of indications are very slightly more conservative for the Addendum 5 cases indicating that the Addendum 5 curve is a slightly more conservative POPCD.

The POB values, because they are so small, are somewhat variable because of the Monte Carlo analysis process.

Therefore, it is not inconsistent that the slightly lower POPCD curve results in a slightly more conservative result.

Compared to the PWSCC ARC that was implemented for Diablo Canyon, the application of a 95th percentile POPCD is very different.

For example, consider a 3-volt indication and assume the indication was plugged. As seen in Figure 23-1 (see page E1-34), the mean POPCD is 0.97, and the 95th percentile is 0.96.

A POD of 0.97 in the ARC analysis means that for every 100 Monte Carlo trials of the population in the SG, there will be 3 indications that are to be included in the analysis. If uncertainties are applied (symmetric about the mean), sometimes the POD will be a little higher and sometimes it will be a little lower. At the end of the analysis, the number of 3-volt indications considered will be 3/100 times the number of Monte Carlo trials.

At the 95th percentile level of POPCD, the POD is 0.96 which means that in the ARC analysis there will be 4 indications for every 100 Monte Carlo trials. Since this is constant, at the end of the analysis the number of 3-volt indications considered will be 4/100 times the number of Monte Carlo trials. The more 3-volt indications considered in the analysis, the more likely one will have a greater probability of burst and leakage, and the more frequently a larger number of large indications contribute to the total leakage. Therefore, it is apparent that using the 95th percentile POPCD is conservative compared to using the mean with uncertainties.

Given that the bases for performing Monte Carlo analyses is to reduce projected burst and leak rate results relative to deterministic analyses such as directly applying the lower 95 percent POPCD curve, there are no plans to include sampling of E1-22

POPCD uncertainties in operational assessments such as applied for Diablo Canyon.

Supplemental Information Since the submittal was prepared, additional data was obtained from the EOC-14 inspection enabling the construction of POPCD which includes the latest data. This cumulative data is shown in Table 10 (see page E1-38) for the EOC-13 POPCD with data through EOC-14. The log-logistic data fit parameters are given in Table 11 (see page E1-39) and the comparison of the EOC-12 POPCD which has been used in the benchmarks and the EOC-13 POPCD are shown in Figure 25-1 (see page E1-35) with an expanded view in Figure 25-2 (see page E1-36). The EOC-13 POPCD is slightly lower than the EOC-12 POPCD because of the increased number of new indications in EOC-14 due to the change in the DSI definition.

Reference

1. EPRI Report NP 7480-L, Addendum 6, 2004 Database Update, Steam Generator Tubing Outside Diameter Stress Corrosion Cracking at Tube Support Plates Database for Alternate Repair Limits, October 2004.

E1-23

Corrected Table 7. Sequoyah-2 and Industry POPCD Log Logistic Distribution Parameters Parameter Sequoyah-2 Sequoyah-2 Industry POPCD POPCD POPCD 30 Inspections at EOC-7 to At EOC-12 EOC-12 Number of Data 6393 1845 46454 Points b0 (Intercept) 1.9947 2.3727 1.9628 b1 (Slope) 2.9920 2.6592 3.1433 V11 3.530E-03 1.467E-02 3.742E-04 V12 6.826E-03 2.767E-02 7.215E-04 V22 1.728E-02 6.962E-02 2.077E-03 Table 19-1 Additions to Table 8. Sequoyah-2 Prior Cycle Benchmarking Results for POPCD Projected S Projected Results As Found Results POB & Leak Growth Rate Used POD Outage G POB Leak No. Max. POB Leak No. Max. Rate Used Rate Ind. Volts(1) Rate Ind. Volts(1) Correlations EOC-13 Projections Reported in Table 8 of POPCD Submittal, 250,000 trials EOC-13 1 1.05x10-3 0.421 342 8.5 1.90x10-5 0.0724 294 1.95 Addendum 5 All SGs: Bounding Cycles 11 Seq.-2

-3 2 1.02x10 0.429 342 8.5 3.10x10-5 0.0769 305 1.97 ¨PSLB = 2405 & 12, Fig. 3-16, Ref. 8 POPCD

-3 3 1.23x10 0.574 406 8.7 5.26x10-5 0.224 412 2.36 psi including largest growth rate.

4 2.78x10-3 1.230 969 8.8 9.24x10-5 0.285 836 1.74 EOC-13 Projections Revised for Changes in Growth Rate and POPCD, 250000 Trials EOC-13 1 9.72x10-5 0.222 342 3.6 1.90x10-5 0.0724 294 1.95 Addendum 5 All SGs: Bounding Cycles 11 Seq.-2

-5 2 9.72x10 0.240 342 3.6 3.10x10-5 0.0769 305 1.97 ¨PSLB = 2405 & 12, Fig. 3-16, Ref. 8 POPCD

-4 3 1.40x10 0.355 406 3.8 5.26x10-5 0.224 412 2.36 psi without largest growth rate.

-4 4 2.26x10 0.722 969 3.9 9.24x10-5 0.285 836 1.74 EOC-13 1 1.30x10-4 0.220 345 3.6 1.90x10-5 0.0724 294 1.95 Addendum 5 All SGs: Bounding Cycles 11 Add. 5

-5 2 7.28x10 0.238 345 3.6 3.10x10-5 0.0769 305 1.97 ¨PSLB = 2405 & 12, Fig. 3-16, Ref. 8 POPCD

-4 3 2.17x10 0.352 409 3.8 5.26x10-5 0.224 412 2.36 psi without largest growth rate.

-4 4 2.67x10 0.722 978 3.9 9.24x10-5 0.285 836 1.74 Notes:

1. Voltage where projected tail accumulates to 0.3 ind.

E1-24

Table 19-1A Additions to Table 8. Sequoyah-2 Prior Cycle Benchmarking Results for Additional Monte Carlo Trials Projected S Projected Results As Found Results POB & Leak Growth Rate Used POD Outage G POB Leak No. Max. POB Leak No. Max. Rate Used Rate Ind. Volts(1) Rate Ind. Volts(1) Correlations EOC-13 Projections Revised for 1 million trials EOC-13 1 8.65x10-5 0.218 342 3.6 1.90x10-5 0.0724 294 1.95 Addendum 5 All SGs: Bounding Cycles 11 Seq.-2 2 7.33x10-5 0.236 342 3.6 3.10x10-5 0.0769 305 1.97 ¨PSLB = 2405 & 12, Fig. 3-16, Ref. 8 POPCD 3 1.32x10-4 0.348 406 3.8 5.26x10-5 0.224 412 2.36 psi without largest growth rate.

4 2.29x10-4 0.715 969 3.9 9.24x10-5 0.285 836 1.74 EOC-13 1 7.66x10-5 0.220 345 3.6 1.90x10-5 0.0724 294 1.95 Addendum 5 All SGs: Bounding Cycles 11 Add. 5 2 8.10x10-5 0.236 345 3.6 3.10x10-5 0.0769 305 1.97 ¨PSLB = 2405 & 12, Fig. 3-16, Ref. 8 POPCD 3 1.57x10-4 0.352 409 3.8 5.26x10-5 0.224 412 2.36 psi without largest growth rate.

4 2.16x10-4 0.722 978 3.9 9.24x10-5 0.285 836 1.74 Notes:

1. Voltage where projected tail accumulates to 0.3 ind.

Table 19-1B Additions to Table 8. Sequoyah-2 Prior Cycle Comparison of Results for Additional Monte Carlo Trials Projected SG 1 Million trials 250,000 Trials Outage POB POB Difference as POB POB Difference as Seq-2 Add 5  % of Seq 2 Seq-2 Add 5  % of Seq 2 POPCD POPCD POPCD POB POPCD POPCD POPCD POB EOC-13 1 8.65x10-5 7.66x10-5 11.4% 9.72x10-5 1.30x10-4 -33.7%

2 7.33x10-5 8.10x10-5 -10.5% 9.72x10-5 7.28x10-5 25.1%

3 1.32x10-4 1.57x10-4 -18.9% 1.40x10-4 2.17x10-4 -55%

4 2.29x10-4 2.16x10-4 5.7% 2.26x10-4 2.67x10-4 -18.1%

E1-25

Table 19-2 Additions to Table 9. Sequoyah-2 EOC-14 Benchmarking Results for POPCD Projected S Projected Results As Found Results POB & Leak Growth Rate Used POD Used Outage G Rate Correlations POB Leak No. Max. POB Leak No. Max.

Rate Ind Volts Rate Ind. Volts EOC-14 Projections Reported in Table 9 of POPCD Submittal EOC-14 1 1.73x10-3 0.400 401 9.3 8.76x10-5 0.108 438 2.36 Addendum 6 All SGs: Bounding Sequoyah-2 1.80x10-3 0.409 412 9.3 6.28x10-5 0.127 507 1.81 ¨PSLB = 2405 Cycle 12, Fig. 3-16, 2 POPCD 3 2.23x10-3 0.667 531 9.6 1.35x10-4 0.266 574 2.27 psi Ref. 8 including 4 4.57x10-3 1.12 1116 9.6 3.55x10-4 0.484 1228 4.74 largest growth rate.

EOC-14 Projections Revised for Changes in Growth Rate EOC-14 1 1.35x10-4 0.160 401 3.7 8.76x10-5 0.108 438 2.36 Addendum 6 All SGs: Bounding Sequoyah-2 9.24x10-5 0.161 412 3.6 6.28x10-5 0.127 507 1.81 ¨PSLB = 2405 Cycle 12, Fig. 3-16, 2 POPCD 3 2.31x10-4 0.352 531 4.0 1.35x10-4 0.266 574 2.27 psi Ref. 8 without largest 4 2.44x10-4 0.509 1116 4.0 3.55x10-4 0.484 1228 4.74 growth rate.

Table 19-3A EOC-14 DSI Indications as Reported in 90 Day Report SG Reported Predictions with Predictions with Underpredicted Percent DSI POD = 0.6 POPCD by POPCD Underpredicted

( 90 Day Report) (Table 19-2) 1 438 489 401 37 8%

2 507 501 412 95 19%

3 574 680 531 43 7%

4 1228 1387 1116 112 9%

Table 19-3B EOC 14 DSI Indications if EOC-13 Definition of DSI is Used SG Revised DSI Predictions with Under/ Over Percent POPCD predicted by Under/Over POPCD predicted 1 403 401 2 under <1% under 2 455 412 33 under 7% under 3 512 531 19 over 4% over 4 1161 1116 45 under 4% under E1-26

Table 19-4 EOC-14 As Found Results for SG 4 POB Leak Rate No. Ind. Max. Volts EOC-14 As Reported in 90 Day Report

-4 3.55x10 0.484 1228 4.74 EOC-14 Revised to EOC 13 Definition of DSI 3.24x10-4 0.451 1161 4.74 Table 19-5 Cycle Length for Benchmark Analyses EOC Number Actual Cycle Analysis Cycle Length, length, EFPD EFPD EOC-11 510.35 510.35 EOC-12 501.6 515 EOC-13 470.9 498 EOC-14 537.1 545 E1-27

Table 21-1 Average Growth Volts/ EFPY SG Cycle 12 Cycle 13 Cycle 14 1 0.0466 0.0456 0.0736 2 0.0699 0.0191 0.0893 3 0.0326* 0.0851 0.097 4 0.0517 0.0358 0.1179 Average 0.0501* 0.0451 0.1012

  • Large growth indication removed Table 21-2 Increase in Average Growth Volts/ EFPY SG Cy12-13 Cy13-14 1 -0.001 0.028 2 -0.0508 0.0702 3 0.0525 0.0119 4 -0.0159 0.0821 Average -0.005 0.0561 Table 21-3 Effect of Average Growth Addition Projected S Projected Results As Found Results POB & Leak Growth Rate Used POD Used Outage G Rate Correlations POB Leak No. Max. POB Leak No. Max.

Rate Ind Volts Rate Ind. Volts EOC-14 Projection From Table 19-2 EOC-14 4 2.44x10-4 0.509 1116 4.0 3.55x10-4 0.484 1228 4.74 Addendum 6 All SGs: Bounding Sequoyah-

¨PSLB = 2405 Cycle 12, Fig. 3-16, 2 POPCD psi Ref. 8 without largest growth rate.

EOC-14 Projection with 0.1V/EFPY adjustment EOC-14 4 3.99x10-4 0.687 1116 4.1 3.55x10-4 0.484 1228 4.74 Addendum 6 All SGs: Bounding Sequoyah-

¨PSLB = 2405 Cycle 12, Fig. 3-16, 2 POPCD psi Ref. 8 without largest growth rate, with 0.1V/EFPY adjustment E1-28

Table 23-1 Sensitivity of POPCD Uncertainties on Results 1 Million Trials Projected S Projected Results As Found Results POB & Leak Growth Rate Used POD Used Outage G Rate Correlations POB Leak No. Max. POB Leak No. Max.

Rate Ind Volts Rate Ind. Volts EOC-13 Projections, 50% CL POPCD EOC-13 4 2.09x10-4 0.701 954 3.9 9.24x10-5 0.285 836 1.74 Addendum 5 All SGs: Bounding Sequoyah-2

¨PSLB = 2405 Cycles 11 & 12, Fig. POPCD, psi 3-16, Ref. 8 without 50%

largest growth rate. confidence EOC-13 Projections, 95% CL POPCD From Figure 19-1A EOC-13 4 2.29x10-4 0.715 969 3.9 9.24x10-5 0.285 836 1.74 Addendum 5 All SGs: Bounding Sequoyah-2

¨PSLB = 2405 Cycles 11 & 12, Fig. 3- POPCD, 95%

psi 16, Ref. 8 without lower bound largest growth rate.

EOC-13 Projections, 99% CL POPCD EOC-13 4 2.05x10-4 0.715 975 3.9 9.24x10-5 0.285 836 1.74 Addendum 5 All SGs: Bounding Sequoyah-2

¨PSLB = 2405 Cycles 11 & 12, Fig. POPCD, psi 3-16, Ref. 8 without 99% lower largest growth rate. bound E1-29

Figure 5-1. Sequoyah-2 and Industry 7/8 POPCD above 1.0 Volt Comparison of Sequoyah-2 and Industry 7/8" Tubing POPCD Weighted Generalized Linear Model Loglogistic Solution 100%

Sequoyah-2 POPCD Regression Probability of Detection Sequoyah-2 POPCD at Lower 95%

Industry 7/8 POPCD Regression Industry POPCD at Lower 95%

90%

80%

1 10 Bobbin Amplitude (Volts)

E1-30

Figure 8-1.

Sequoyah 2 EOC-14: RMS Inferred Bobbin Volts from Multiple SAIs 6

Bobbin Volts Inferred fromMultiple SAIs 5.5 5

4.5 4

3.5 3

2.5 2

RMS Inferred Bobbin 1.5 Volts 1 Ideal Equivalent Volts 0.5 0

0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 Measured Bobbin Volts Figure 8-2.

Sequoyah Unit 2 EOC-14 Plus Point Volts to Bobbin Volts Correlation 5.00 4.50 2

y = 0.0174x + 1.0398x + 0.9276 4.00 3.50 Bobbin DSI Volts 3.00 2.50 2.00 1.50 1.00 SAI Data (no DNTs)

Mean Regression Line 0.50 Upper 95% Confidence of Mean Poly. (Upper 95% Confidence of Mean) 0.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 Plus Point SAI Volts E1-31

Figure 16-1. POPCD for Sequoyah-2 Cycles 7-12 and Cycle 12 above 1.0 Volt Comparison of Sequoyah-2 EOC 7-12 and EOC 12 POPCD above 1.0 Volt Weighted Generalized Linear Model Loglogistic Solution 100%

Sequoyah-2 EOC 7-12 POPCD Sequoyah-2 EOC 12 POPCD Sequoyah-2 EOC 7-12 POPCD at Lower 95%

Probability of Detection Sequoyah-2 EOC 12 POPCD at Lower 95%

90%

80%

1 10 Bobbin Amplitude (Volts)

E1-32

Figure 19-1 Comparison of Generic POPCD for 7/8" Add. 5 & Sequoyah-2 POPCD of Fig. 3 (Weighted Generalized Linear Model Loglogistic Solution - Fractional POD Data Shown for Information Only) 100%

POPCD for Addendum 5 Database 90% POPCD at Lower 95% for Addendum 5 POPCD for Seq. 2, Fig. 3 POPCD for Seq. 2, Fig. 3 Lower 95%

80%

70%

Probability of D etection 60%

50%

40%

30%

20%

10%

0%

0.01 0.1 1 10 Bobbin Amplitude (Volts)

E1-33

Figure 19-2 Expanded View of Figure 19-1 Comparison of Sequoyah-2 and ADD 5 7/8" Tubing POPCD Weighted Generalized Linear Model Loglogistic Solution 100%

99%

98%

97%

96%

Probability of Detection 95%

94%

93%

92%

91%

90% Sequoyah-2 POPCD Regression 89% Sequoyah-2 POPCD at Lower 95%

Add 5 7/8 POPCD Regression 88%

Add 5 POPCD at Lower 95%

87%

86%

85%

1 10 Bobbin Amplitude (Volts)

Figure 23-1 E1-34

Comparison of 50th, 95th and 99th Percentile Sequoyah 2 POPCD 1.00 0.99 0.98 95th Percent Lower 0.97 Bound 0.96 CDF 99th Percent Lower 0.95 0.94 Bound 0.93 50% confidence 0.92 0.91 0.90 1 10 100 Volts Figure 25-1 E1-35

Comparison of Sequoyah-2 EOC-12 and EOC-13 POPCD Weighted Generalized Linear Model Loglogistic Solution 100%

Seq.-2 EOC-12 POPCD Regression 90%

Seq.-2 EOC-12 POPCD at Lower 95%

80%

Seq.2 EOC-13 POPCD Regression Seq.2 EOC-13 POPCD at Lower 95%

70%

Probability of Detection 60%

50%

40%

30%

20%

10%

0%

0.01 0.1 1 10 Bobbin Amplitude (Volts)

Figure 25-2 E1-36

Comparison of Sequoyah-2 EOC-12 and EOC-13 POPCD Weighted Generalized Linear Model Loglogistic Solution 100%

99%

98%

97%

96%

Probability of Detection 95%

94%

93%

92%

91%

90%

Seq.-2 EOC-12 POPCD Regression 89%

Seq.-2 EOC-12 POPCD at Lower 95%

88%

Seq.2 EOC-13 POPCD Regression 87%

Seq.2 EOC-13 POPCD at Lower 95%

86%

85%

1 10 Bobbin Amplitude (Volts)

E1-37

Table 10: Sequoyah-2 Composite POPCD Summary Evaluation for Results for EOC-7 (1996) thru EOC-14 (2006) for POPCD at EOC-6 thru EOC-13 Column A B C D E F G H I J K Sequoyah-2 Specific POPCD Data Table Detection at EOCn No Detection at EOCn (New Indications)

EOCn Bobbin Ind. RPC EOCn Bobbin Ind. Not RPC New EOCn+1 Bobbin RPC New EOCn+1 Bobbin Not RPC Ind. Found Only by RPC at EOCn+1 EOCn RPC NDD Bobbin Excluded from Totals for POPCD EOCn Bobbin Ind. Repaired at EOCn (3) (2)

Confirmed at EOCn+1 Inspected at EOCn+1 Confirmed Inspected or at EOCn & Plugged at EOCn Indications POPCD Evaluation BDD / RDD BDD / RDD BDD w/o RPC BDD w/o RPC BDD / RDD Plugged at EOCn BND w/o RPC BDD / RDD BND w/o RPC BDD w/o RPC BND w/o RPC BND / RDD BDD / RND BDD w/o RPC All RND AT EOCn+1 Voltage BDD / RDD BND / RDD BDD / RDD BDD w/o RPC BDD w/o RPC Plugged at EOCn BND / RDD BDD / RDD BND / RDD BDD w/o RPC BND / RDD BND / RDD BDD / RND BDD / RDD All BND w/o RPC Detection No POPCD for Bin BDD w/o RPC BDD / RDD BND / RND BDD / RDD BND / RND BDD w/o RPC BND / RND BND / RDD BDD / RND BND / RDD at EOCn+1 at EOCn Detection Voltage Bin BDD w/o RPC BND / RDD BND / RDD Plugged at EOCn BDD/RND/Plugged at EOCn (1)

Note at EOCn 0.01-0.10 0 4 0 3 35 0 0 2 4 38 0.095 0.11-0.20 6 181 1 11 330 0 0 71 188 341 0.355 0.21-0.30 20 667 7 28 501 0 5 147 694 534 0.565 0.31-0.40 25 1007 9 38 498 0 6 123 1041 542 0.658 0.41-0.50 34 1018 12 43 332 0 8 97 1064 383 0.735 0.51-0.60 44 824 11 49 226 1 6 90 879 282 0.757 0.61-0.70 62 672 5 41 151 0 10 60 739 202 0.785 0.71-0.80 94 454 5 23 71 3 6 54 553 103 0.843 0.81-0.90 107 298 5 25 49 2 1 47 410 77 0.842 0.91-1.00 99 163 5 22 25 1 9 32 267 57 0.824 1.01-1.10 105 70 1 13 10 1 4 19 176 28 0.863 1.11-1.20 85 44 2 9 6 2 6 19 131 23 0.851 1.21-1.30 55 20 1 4 1 1 1 15 76 7 0.916 1.31-1.40 30 11 2 5 0 1 3 14 43 9 0.827 1.41-1.50 27 8 2 6 0 0 0 8 37 6 0.860 1.51-1.60 18 5 3 0 1 1 1 1 26 3 0.897 1.61-1.70 15 4 1 0 0 1 0 1 20 1 0.952 1.71-1.80 4 1 3 0 0 0 0 1 8 0 1.000 1.81-1.90 2 0 0 0 0 0 0 5 2 0 1.000 1.91-2.00 4 2 1 1 0 0 0 1 7 1 0.875 2.01-2.10 0 0 4 0 0 0 0 2 4 0 1.000 2.11-2.20 0 0 1 0 0 0 0 0 1 0 1.000 2.21-2.30 0 0 1 0 0 0 0 0 1 0 1.000 2.31-2.40 0 0 1 0 0 0 0 0 1 0 1.000 2.41-2.50 0 0 2 0 0 0 0 0 2 0 1.000 2.51-2.60 0 0 0 0 0 0 0 0 0 0 3.21-3.30 0 0 0 0 0 0 0 0 0 0 3.31-3.40 0 0 1 0 0 0 0 0 1 0 1.000 3.41-3.50 0 0 0 0 0 0 0 0 0 0 3.51-3.60 0 0 1 0 0 0 0 0 1 0 1.000 3.61-3.70 0 0 0 0 0 0 0 0 0 0 9.61-9.70 0 0 0 0 0 0 0 0 0 0 9.71-9.80 0 0 1 0 0 0 0 0 1 0 1.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Total 836 5453 88 321 2236 14 66 809 6377 2637 0.707 Notes:

1) POPCD for each voltage bin calculated as (Detection at EOCn)/(Detection at EOCn + No Detection at EOCn). By column, POPCD = (A+B+C)/(A+B+C+D+E+F+G).
2) EOCn RPC NDD bobbin indications are treated as new indications per NRC request
3) Includes indications at EOCn plugged at EOCn and new indications at EOCn+1, not reported in the bobbin inspection, and found only by RPC inspection of dents, mixed residuals or other reasons for the RPC inspection.
4) BDD = Bobbin detected indication; BND = Bobbin NDD intersection; RDD = RPC detected indication; RND = RPC NDD intersection E1-38

Table 11 Sequoyah Unit 2 EOC-13 POPCD Log-Logistic Distribution Parameters Parameter Sequoyah Unit 2 POPCD at EOC-13 Number of Data Points 9014 b0 (intercept) 1.8865 b1 (Slope) 2.7789 V11 2.308E-03 V12 4.489E-03 V22 1.169E-02 E1-39

ENCLOSURE 2 TENNESSEE VALLEY AUTHORITY (TVA)

SEQUOYAH NUCLEAR PLANT (SQN)

UNIT 2 REFORMATTED TECHNICAL SPECIFICATION (TS) AND BASES PAGE MARKUPS FOR SQN TS CHANGE 06-06, PROBABILITY OF PRIOR CYCLE DETECTION E2-1

ADMINISTRATIVE CONTROLS STEAM GENERATOR (SG) TUBE INSPECTION REPORT (continued)

a. The scope of inspections performed on each SG,
b. Active degradation mechanisms found,
c. Nondestructive examination techniques utilized for each degradation mechanism,
d. Location, orientation (if linear), and measured sizes (if available) of service induced indications,
e. Number of tubes plugged during the inspection outage for each active degradation mechanism,
f. Total number and percentage of tubes plugged to date,
g. The results of condition monitoring, including the results of tube pulls and in-situ testing, and
h. The effective plugging percentage for all plugging in each SG.

6.9.1.16.2 A report shall be submitted within 90 days after the initial entry into MODE 4 following completion of an inspection performed in accordance with the steam generator program (6.8.4.k) when voltage based alternate repair criteria have been applied. The report shall include information described in Section 6.b of Attachment 1 to NRC Generic Letter 95-05, Voltage-Based Repair Criteria for Westinghouse Steam Generator Tubes Affected by Outside Diameter Stress Corrosion Cracking.

6.9.1.16.3 For implementation of the voltage-based repair criteria for tube support plate (TSP) intersections, notify the staff prior to initial entry into MODE 4 following completion of an inspection performed in accordance with Specification 6.8.4.k, Steam Generator (SG) Program, should any of the following conditions arise:

1) If circumferential crack-like indications are detected at the TSP intersections.
2) If indications are identified that extend beyond the confines of the TSP.
3) If indications are identified at the TSP elevations that are attributable to primary water stress corrosion cracking.

6.9.1.16.4 For implementation of W*, the calculated steam line break leakage from the application of TSP alternate repair criteria and W* inspection methodology shall be submitted within 90 days after the initial entry into MODE 4 following completion of an inspection performed in accordance with Specification 6.8.4.k, Steam Generator (SG) Program. The report will include the number of INSERT 1 indications within the tubesheet region, the location of the indications (relative to the bottom of the WEXTEX transition [BWT] and TTS), the orientation (axial, circumferential, skewed, volumetric), the severity of each indication (e.g., near through-wall or not through-wall), the side of the tube from which the indication initiated (inside or outside diameter), and an assessment of whether the results were consistent with expectations with respect to the number of flaws and flaw severity (and if not consistent, a description of the proposed corrective action).

May 22, 2007 SEQUOYAH - UNIT 2 6-14a Amendment No. 305 E2-2

INSERT 1 6.9.1.16.5 For implementation of the probability of prior cycle detection (POPCD) method, for the voltage-based repair criteria at tube support plate intersections, if the end-of-cycle conditional tube rupture probability for a postulated main steam line break, the projected primary to secondary leak rate during a postulated main steam line break, or the number of indications are under predicted by the previous cycle operational assessment, the following shall be reported to the Commission within 90 days after initial entry into MODE 4 following completion of inspection performed in accordance with specification 6.8.4.k, Steam Generator Program.

1. The assessment of the probable causes for the under prediction, proposed corrective actions, and any recommended changes to probability of detection or growth methodology indicated by potential methods assessments.
2. An assessment of the potential need to revise the alternate repair criteria analysis methods if: the burst probability is under predicted by more than 0.001 (i.e.,

10 percent of the performance criteria) or an order of magnitude; or the leak rate is under predicted by more than 0.5 gallon per minute (gpm) or an order of magnitude.

3. An assessment of the potential need to increase the number of predicted low voltage indications at the beginning of cycle if the total number of as-found indications in any SG are underestimated by greater than 15 percent or by greater than 150 indications.

E2-3

INSERT 2 REACTOR COOLANT SYSTEM BASES where VGR represents the allowance for flaw growth between inspections and VNDE represents the allowance for potential sources of error in the measurement of the bobbin coil voltage. Further discussion of the assumptions necessary to determine the voltage repair limit are discussed in GL 95-05.

The mid-cycle equation of SR 4.4.5.4.a.10.e should only be used during unplanned inspection in which eddy current data is acquired for indications at the tube support plates.

SR 4.4.5.5 implements several reporting requirements recommended by GL 95-05 for situations which NRC wants to be notified prior to returning the S/Gs to service. For SR 4.4.5.5.d., Items 3 and 4, indications are applicable only where alternate plugging criteria are being applied. For the purposes of this reporting requirement, leakage and conditional burst probability can be calculated based on the as-found voltage distribution rather than the projected end-of-cycle voltage distribution (refer to GL 95-05 for more information) when it is not practical to complete these calculations using the projected EOC voltage distributions prior to returning the S/Gs to service. Note that if leakage and conditional burst probability were calculated using the measured EOC voltage distribution for the purposes of addressing GL Sections 6.a.1 and 6.a.3 reporting criteria, then the results of the projected EOC voltage distribution should be provided per GL Section 6.b(c) criteria.

Wastage-type defects are unlikely with proper chemistry treatment of the secondary coolant. However, even if a defect should develop in service, it will be found during scheduled inservice steam generator tube examinations. Plugging will be required for all tubes with imperfections exceeding the repair limit defined in Surveillance Requirement 4.4.5.4.a. The portion of the tube that the plugging limit does not apply to is the portion of the tube that is not within the RCS pressure boundary (tube end up to the start of the tube-to-tubesheet weld).

The tube end to tube-to-tubesheet weld portion of the tube does not affect structural integrity of the steam generator tubes and therefore indications found in this portion of the tube will be excluded from the Result and Action Required for tube inspections. It is expected that any indications that extend from this region will be detected during the scheduled tube inspections. Steam generator tube inspections of operating plants have demonstrated the capability to reliably detect degradation that has penetrated 20% of the original tube wall thickness.

Tubes experiencing outside diameter stress corrosion cracking within the thickness of the tube support plate are plugged or repaired by the criteria of 4.4.5.4.a.10.

The W* criteria incorporate the guidance provided in WCAP-14797, Revision 2, Generic W* Tube Plugging Criteria for 51 Series Steam Generator Tubesheet Region WEXTEX Expansions. W* length is the length of tubing into the tubesheet below the bottom of the WEXTEX transition (BWT) that precludes tube pullout in the event of a complete circumferential separation of the tube below the W* length. W* distance is the distance from the top of the tubesheet to the bottom of the W* length including the distance from the top of the tubesheet to the BWT and measurement uncertainties.

Indications detected within the W* distance below the top-of-tube sheet (TTS), will be plugged upon detection. Tubes to which WCAP-14797 is applied can experience through-wall degradation up to the limits defined in Revision 2 without increasing the probability of a tube rupture or large leakage event. Tube degradation of any type or extent below W* distance, including a complete circumferential separation of the tube, is acceptable. As applied at Sequoyah Nuclear Plant Unit 2, the W* methodology is used to define the required tube inspection depth into the hot-leg tubesheet, and is not used to permit degradation in the W* distance to remain in service. Thus while primary to secondary leakage in the W* distance need not be postulated, primary to secondary leakage from potential degradation below the W* distance will be assumed for every inservice tube in the bounding steam generator.

May 3, 2005 SEQUOYAH - UNIT 2 B 3/4 4-3a Amendment No. 181, 211, 213, 243, 291 E2-4

INSERT 2 For the operational assessment, the Probability of Prior Cycle Detection (POPCD) voltage based probability of detection (POD) method, as described in a September 15, 2006 letter from Westinghouse Electric Company to TVA (LTR-CDME-06-121, Technical Support for Application of Probability of Prior Cycle Detection for Sequoyah Unit 2 Voltage Based Alternate Repair Criteria), is used to determine the beginning of cycle voltage distributions. The POPCD method is an exception to the GL 95-05 guidance that requires the application of a POD of 0.6 to all previous bobbin indications.

Approved by NRC letter dated _________________.

E2-5

ENCLOSURE 3 TENNESSEE VALLEY AUTHORITY (TVA)

SEQUOYAH NUCLEAR PLANT (SQN)

UNIT 2 TVA COMMITMENT TVA will revise SQNs steam generator program to incorporate the methodology for implementation of Probability of Prior Cycle Detection (POPCD) as described in Enclosure 1 of this submittal.

The program revision will be completed within 45 days following NRC approval of the SQN Unit 2 POPCD TS Change 06-06.

E3-1