ML20066C377: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
Line 2: Line 2:
| number = ML20066C377
| number = ML20066C377
| issue date = 10/31/1990
| issue date = 10/31/1990
| title = Nonproprietary LOFTTR2 Analysis for Steam Generator Tube Rupture for Beaver Valley Power Station Unit 2.
| title = Nonproprietary LOFTTR2 Analysis for Steam Generator Tube Rupture for Beaver Valley Power Station Unit 2
| author name = Holderbaum D, Lewis R, Schrader K
| author name = Holderbaum D, Lewis R, Schrader K
| author affiliation = WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
| author affiliation = WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.

Revision as of 00:33, 6 January 2021

Nonproprietary LOFTTR2 Analysis for Steam Generator Tube Rupture for Beaver Valley Power Station Unit 2
ML20066C377
Person / Time
Site: Beaver Valley
Issue date: 10/31/1990
From: Holderbaum D, Robert Lewis, Schrader K
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
Shared Package
ML19310D128 List:
References
WCAP-12738, NUDOCS 9101090500
Download: ML20066C377 (85)


Text