- L-87-489, Responds to Violations Noted in Insp Repts 50-250/87-39 & 50-251/87-39.Corrective Actions:Fuse Insp Expanded to Include Nuclear Instrumentation,Qualified Safety Parameter Display & post-accident Sampling Sys for Both Units + (November 25, 1987)
- IR 05000528/1987041 + (November 25, 1987)
- IR 05000397/1987029 + (November 25, 1987)
- ML17146B053 + (November 25, 1987)
- ML16341E454 + (November 25, 1987)
- IR 05000269/1987043 + (November 25, 1987)
- IR 05000261/1987034 + (November 25, 1987)
- 05000206/LER-1987-014-02, :on 870626,determined That Battery Weekly Surveillance Not Performed Prior to Mode Change,Contrary to Tech Spec 4.0.4.Caused by Personnel Error.Individual Involved Reinstructed + (November 25, 1987)
- ML17199T450 + (November 25, 1987)
- ML18152A601 + (November 25, 1987)
- TAC:M54555 + (November 25, 1987)
- ML17221A526 + (November 25, 1987)
- ML17055D418 + (November 25, 1987)
- ML16152A776 + (November 25, 1987)
- ML17300B126 + (November 25, 1987)
- ML17303A714 + (November 25, 1987)
- TAC:66071 + (November 25, 1987)
- A01328, Forwards Response to SER Open Items Re NUREG-0737,Item II.B.1, Reactor Coolant Sys Vents & Insp Rept 50-336/84-07 + (November 25, 1987)
- IR 05000353/1987011 + (November 25, 1987)
- ML20236U035 + (November 25, 1987)
- ML20236S830 + (November 25, 1987)
- 05000327/LER-1986-015, :on 860407 & 09,failure to Properly Functional Test Reactor Coolant Pump Devices & Electrical Breakers Noted.Caused by Inadequate Test Procedure.Procedure Revised to Ensure Use of Proper Test Techniques + (November 25, 1987)
- 05000327/LER-1987-065, :on 871023,ERCW Screen Wash Pumps Omitted from ASME Section XI Test Program Resulting in Potential Degradation of ERCW Flow.Caused by Personnel Error.Test Program Revised to Include Wash Pumps + (November 25, 1987)
- 05000458/LER-1987-023, :on 871019,cooling Water Lines to HX 1RMS*HX11A Serving Radiation Monitor 1RMS*RE11A Found Plugged Due to Corrosion Buildup.Caused by Condition of Svc Water Chemistry.Lines Cleaned or Replaced + (November 25, 1987)
- 05000412/LER-1987-033, :on 871028,discovered That Wide Range Gas Monitor Channel C&D Not Performed within Required Monthly Frequency.Caused by Personnel Error.Operating Surveillance Test Schedule Data Base Revised + (November 25, 1987)
- 05000440/LER-1987-073, :on 871029,three MSIVs Failed to Fast Close in Time Required by Tech Specs 3.4.7 & 3.6.4.On 871103,two MSIVs Failed to Close.Caused by Sticking of Fast Closure Dual Solenoid Air Pilot Valves.Elastomer Discs Replaced + (November 25, 1987)
- 05000344/LER-1987-032, :on 870417,RCS Wide Range Pressure Transmitters PT-403 & PT-405 Found Out of Calibr.Caused by Transmitter Drift.Transmitters Recalibrated & Preinstallation Acceptance Test Being Evaluated for Adequacy + (November 25, 1987)
- ML17300B129 + (November 26, 1987)
- ML20147F781 + (November 26, 1987)
- ML20236Y540 + (November 26, 1987)
- ML20236W494 + (November 26, 1987)
- ML17221A530 + (November 27, 1987)
- ML17221A528 + (November 27, 1987)
- IR 05000498/1987066 + (November 27, 1987)
- ML20238C566 + (November 27, 1987)
- ML20237C144 + (November 27, 1987)
- ML20237C137 + (November 27, 1987)
- ML20237C133 + (November 27, 1987)
- ML20237B926 + (November 27, 1987)
- ML20247Q683 + (November 27, 1987)
- IR 05000324/1987041 + (November 27, 1987)
- ML20236X918 + (November 27, 1987)
- IR 05000267/1987024 + (November 27, 1987)
- IR 05000322/1987018 + (November 27, 1987)
- ML20236V822 + (November 27, 1987)
- ML20236V723 + (November 27, 1987)
- ML20236V687 + (November 27, 1987)
- ML20236V398 + (November 27, 1987)
- ML20236V396 + (November 27, 1987)
- ML20236V023 + (November 27, 1987)
- PNO-III-87-145, on 871125,licensee Reviewed Info from 711105 Contamination Incident Involving Am-241.Caused by Leaking Sealed Source Which Contaminated Two Room Lab.Region Will Inspect Util Plans for Radwaste Inventory + (November 27, 1987)
- ML20236U967 + (November 27, 1987)
- ML20236U688 + (November 27, 1987)
- PNO-V-87-079, on 871126,digital Voltmeter Connected to Wrong Terminal Resulting in Inadvertent Opening of Safety Relief Valve 2D.Caused by Technician Error.Position of Safety Relief Valve Identified & Shut + (November 27, 1987)