November 25, l987 Docket No. 50-335 Hr. C. 0. l,'oody Group Yice President Nuclear Energy Florida Power and Light Company Post Office Box 14000 Juno Beach, Florida 33408
Dear Hr. Hoody:
DISTRIBUTION
PD22 Reading Gray File S. Yarga/G. Lainas D. Miller E. Tourigny kf. Berkow OGC-Bethesda E. Jordan J. Partlow
SUBJECT:
RE(VEST FOR ADDITIONAL INFORMATION (TAC NO. 65587)
In conducting our review of your June 12, 1987 submittal relating to expanding the spent fuel pool storage capacity at the St. Lucie Plant, Unit No.
1, we have determined that we will need additional information identified in the enclosure to continue our review.
In order for us to maintain our review schedule, your response is requested by December 16, 1987.
He are also prepared to meet with your staff to discuss the responses to expedite our review.
The reporting and/or recordkeeping requirements contained in this letter affect fewer than 10 respondents; therefore, OHB clearance is not required under P.L.96-511.
Please contact me at (301) 492-9786 if you have any questions concerning this letter.
Sincere ly, Original sigend by H.. Berkow for E.
G. Tourigny, Project Hanager Project Directorate II-2 Division of Reactor Projects-I/II
Enclosure:
As stated cc w/enclosure:
See next page 11'87 PYi: +
D:
2 ETu g
g He w
11 2487 1
/D8%'87
'4 i
8712010187 871125 PDR ADOCK 05000335t,-
P PDRQ
ga~ "<Gus
~c+
+
)
I 0
IIA O~
Op
+~
~O
+w*w+
Docket No. 50-335 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 November 25> 1987 Nr. C. 0. Moody Group Vice President Nuclear Energy Florida Power and Light Company Post Office Box 14000 Juno Beach, Florida 33408
Dear Mr. Voody:
SUBJECT:
RE(VEST FOR ADDITIONAL INFORMATION (TAC NO. 65587)
In conducting our review of your June 12, 1987 submittal relating to expanding the spent fuel pool storage capacity at the St. Lucie Plant, Unit No. 1, we have determined that we will need additional information identified in the enclosure to continue our review.
In order for us to maintain our review schedule, your response is requested by December 16, 1987.
tte are also prepared to meet with your staff to discuss the responses to expedite our review.
The reporting and/or recordkeeping requiremenIts contained in this letter affect fewer than 10 respondents; therefore, ONB clearance is not required under P.L.96-511.
Please contact me at (301) 492-9786 if you have any questions concerning this letter.
Sincerely,
Enclosure:
As stated cc w/enclosure:
See next page
. Tourigny, Project Mana er Project Directorate II-2 Division of Reactor Projects-I/II
Mr. C. 0. Woody Florida Power A Light Company St. Lucie Plant CC:
Nr. Jack Shreve Office of the Public Counsel Room 4, Holland Building Ta 1 1ahassee, Florida 32304 Resident Inspector c/o U.S.
NRC 7585 S.
Hwy AlA Jensen Beach, Florida 34957 State Planning 8 Development C lear inghouse Office of Planning
- 8. Budget Executive Office of the Governor The Capitol Building Tallahassee, Florida 32301 Harold F. Reis, Esq.
Newman 8, Holtzinger 1615 L Street, N.M.
Washington, DC 20036 John T. Butler, Esq.
- Steel, Hector and Davis 4000 Southeast Financial Center Miami, Florida 33131-2398 Acministrator Department of Environmental Regulation Power Plant Siting Section State of Florida 2600 Blair Stone Road Tallahassee, Florida 32301 Yr. Meldon B. Lewis, County Administrator St. Lucie County 2300 Virginia Averue, Room 104 Fort Pierce, Florida 33450 Mr. Charles B. Brinkman, Manager Washington - Nuclear Operations Combustion Engineering, Inc.
7910 Moodmont Avenue
- Bethesda, Marylard 20814 Jacob Daniel Nash Office of Radiation Control Department of Health and Rehabilitative Services 1317 Minewood Blvd.
Tallahassee, Florida 32399-0700 Regioral Administrator, Region II U.S. Nuclear Regulatory Colt;mission Executive Director for Operations 101 Yarietta Street N.M., Suite 2900 Atlanta, Georgia 30323
ewrLQSURE RE(VEST FOR ADDITIONAL INFORMATION (RAI)
ST.
LUCIE 1
SPENT FUEL STORAGE POOL Answer guestion 7, part 3 of the July 16, 1987 RAI, especially related to the safety factors.
V Provide the results of the failure of the temporary crane's
- hook, assuming that it is lifting the heaviest rack at the maximum carrying height.
3.
Provide the stress levels in the temporary crane when the heaviest rack is dropped onto it from the maximum carrying height associated with the cask handling crane.
(If the cask handling crane is single-failure proof, then dropped means the maximum possible lowering velocity associated with the cask handling crane).
4.
Does Figure 1 (September 8,
1987 submittal) represent the locations occupied by the spent fuel before the temporary cr ane is installed?
5.
Provide the results of a light load drop analysis which includes a list of the objects considered, their weight and their maximum carrying height as well as the same information related to the referenced load.
As an alter-native, provide a discussion of the effects of having the new racks on a
previously-approved light load drop analysis.