t DUKE POWER COMPANY CATAWBA NUCLEAR STATION UNIT 1 DOCKET NO. 50-413 REACTOR CONTAINMENT BUILDING INTEGRATED LEAK RATE TEST NOVEMBER 24-26, 1987

~

8803090036 871126 hDI'}fI PDR ADOCK 05000413 P

DCD

/-

e e

i Duxn Powen ConnueY P.O. BOX 33180 CitAttLorrE, N.C. 28242 IIAL U. TUCKER retzrnowz (704) 373-4 511 vua en e.m,=,

ptWL E AR P9pD('CTtrnN February 25, 1988 U. S. Nuclear Regulatory Commission Attention:

Document Control Desk Washington, D. C. 20555

Subject:

Catawba Nuclear Station, Unit 1 Docket No. 50-413 Reactor Containment Building Integrated Leak Rate Test Gentlemen:

Pursuant to 10 CFR 50, Appendix J, Section V.B and Technical Specification 4.6.1.2, please find attached the CataNba Nuclear Station Unit 1 Reactor Containment Building Integrated Leak Rate Test (ILRT) Report.

The ILRT was successfully completed on November 28, 1988, and analysis of final test data shows the results to be well within the appropriate liinits.

Very truly yours, d

t'

/

/

Hal B. Tucker JGT/1451/sbn Attachment l

xc:

Dr. J. Nelson Grace, Regional Administration U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 0l i Atlanta, Georgia 30323 I

k Mr. P. K. Van Doorn NRC Resident Inspector

[

Catawba Nuclear Station L

l l

DUKE POWER COMPANY CATAWBA NUCLEAR STATION UNIT 1 REACTOR CONTAINMENT BUILDING j

INTEGRATED LEAK RATE TEST (INITIAL PERIODIC TEST)

CONDUCTED NOVEMBER 24-26, 1987 FILE NO:

CN-180.25 i

I Prepared By: M/_

u M. A.'Geckle Asso te E er Reviewed By[ [ !<

7. L. Ta91or Test Engineer Reviewed By:

M W. F. Belver I

rfo ance Engineer Approved By:

R. F. Wardell Superintendent, Technical Services f j t

~.

1 i

l i

l TABLE OF CONTENTS i

l Section Page I. INTRODUCTION....

1 II. TEST BACKGROUND INFORMATION 2.

A.

Description of Containment.

2 r

B.

Description of ILRT Instrumentation 2

F 1.

Pressure Instrumentation.....

3 2.

Temperature Instrumentation 3

3.

Humidity Instrumentation.

4 j

4.

Data Acquisition Facility 4

l S.

Flow Instrumentation.

5 6.

Instrumentation Selection Guide (ISG) Calculation..

5 C.

Description of Computer Program 5

D.

Description of Pressurization Equipment 6

TII. TEST RESULTS.

7 A.

Description of the Testing Sequence 7

i i

i B.

Analysis and Interpretation 9

1.

Temperature Stabilization 9

l 2.

Pressure Decay (24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />) Test 9

3.

Superimposed Leak Rate Test 10 4

IV. FIGURES 11 l

i l

A.

Temperature Stabilization Plots 4

B.

Pressure Decay (24 Hour) Test Plots C.

Superimposed Leak Rate Test Plots

]

D.

Miscellaneous Plots 1

1 d

1 i

I I

1 1

1

TABLE OF CONTENTS (Continued)

V. APPENDICES i

A.

Leak Rate Calculations Description 1

B.

Test Log of Significant Events C.

RTD Locations D.

Leakage Penalty Analysis E.

Leakage Savings Analysis F.

Local Leakage Rate Testing Conducted Since the Last ILRT G.

Test Data 1

I

I INTRODUCTION l

The initial periodic Containment Integrated Leak Rate Test on the primary containment structure of the Duke Power Company Catawba Nuclear Station Unit 1 Pressurized Water Reactor was successfully completed on November 26, 1987. The ILRT was conducted in conformance with the i

requirements of 10CFR50 Appendix J (and associated ANSI standards) and Catawba Technical Specifications. A 24-hour test was performed utilizing the absolute test method and mass plot data analysis technique with the containment pressure > 14.68 psig (calculated peak containment accident pressure). The results were verified by the satisfactory completion of a superimposed leak rate test.

Analysis of final test data shows the results to be well within the specified limits for this containment.

The acceptance criterion for this test is that the containment integrated leakage rate be less than 0.15 percent by weight of the containment air mass per day for both the "As-Found" and "As-Left" cases. The actual test results are 0.06141%/ day for the "As-Found" Type A leakage rate (95% UCL leakage rate + Leakage Penalties + Leakage Savings) and 0.052167/ day for the "As-Lef t" Type A leakage rate (95% UCL leakage rate + Leakage Penalties).

4

+

i 4

I a

}

l l

y n.-

t-

II. TEST BACKGROUND INFORMATION A.

Description of Containment The Catawba Unit 1 Containment System consists of a free-standing steel containment vessel surrounded by a separate concrete reactor building.

A six foot annular space is provided between the outer wall of the containment vessel and the inner wall of the reactor building to allow filtration of containment vessel leakage during accident conditions to'ainimize off-site doses. The following containment vessel specifications are.used as base data for the containment leak rate test.

3 Containment Net Free Volume 1,172,618 ft Design Pressure 15 psig Calculated Peak Accident Pressure 14.68 psig Test Pressure

> 14.68 psig Test Temperature Ambient Maximum Allowable Leakage Rate (L,)

0.2 weight %/ day B.

Description of ILRT Instrumentation The containment system was equipped with instrumentation to permit leakage rate determination by the absolute method. Utilizing this method, the actual mass of dry air within the containment is calculated. The leakage rate becomes the time rate of change of this value.

The mass of air (W) is calculated according to the ideal gas law as follows:

W = (P-Pv)V RT Where:

P = Containment Absolute Pressure Pv = Partial Pressure of Water Vapor V = Containment Net Free Volume R = Gas Constant T = Containment Absolute Temperature The primary measurement variables required are containment absolute pressure, containment relative humidity, and containment temperature as a function of time. During the supplemental verification test, containment bleed-off flow is also recorded.

2

52 Resistance Temperature Detectors, 3 Dewpoint Hygrometers, and 3 Pressure Sensors are installed at predetermined locations in the containment vessel to allow determination of weighted average I

temperatures, vapor pressures, and pressures.

For analysis purposes, the containment is divided into three compartments, with the following specifications:

1 Volume

  1. Dewpoint
  1. Pressure Compartment Fraction RTDs Hygrometers Sensors Lower Containment 0.271 24 1

1 Upper Containment 0.595 13

'l 1

Ice' Condenser 0.134 15 1

1 Totals 1.0 52 3

3 l

l 1.

Pressure Instrumentation Three precision pressure gauges were installed outside the containment vessel, with pressure tubing connecting each gauge to its applicable compartment containment penetration. The gauges used were Ruska Model 6000-801-40 psia gauges, with the following specifications:

Range:

0 to 40 psia Repeatability: 24 Hr: 't 0.0008 psi 90 Day: 1 0.0016 psi Accuracy: 1(0.01% Full Scale + 0.011% Reading) or better, traceable to NBS Sensitivity:

1 0.002% FS Output:

DC Analog Output (0-4 v) to Digital Meter for display and Accurex for recording.

2.

Temperature Instrumentation Fifty-two precision Resistance Temperature Detectors were located throughout the containment to allow measurement r

of the weighted average air temperature. The locations of 4

the RTDs are shown in Appendix C.

The RTDs used were Rosemount Model No. 78S, with the following specifications:

Range:

0 to 200*F Repeatability: 1 0.025% over entire range Accuracy:

0.45*F over entire range Sensitivity: 2 0.09*F 1

Element:

Platinum Resistance:

100 ohms at 32*F (nominal) i

\\

r 3

L L

1 3.

Humidity Instrumentation Six Dewpoint Temperature Analyzers were located in containment.

(Each compartment had one primary and one backup dewpoint cell installed side-by-side.) The locations of the dewpoint cells are also shown in Appendix C.

The instruments used were EG&G Dewtrack Model 200, with the following specifications:

Range:

-43.6'F to 140*F Accuracy: i l'F, traceable to NBS Sensitivity:

1 0.36'F worst case Output:

4-20 mA 4.

Data Acquisition Facility The ILRT instrumentation system consists of a central data acquisition system with a-remote scanner / multiplexer unit.

All RTDs are wired to the remote scanner / multiplexer unit located inside containment; the signals are then multiplexed and sent to the central data acquisition facility. All other sensors are wired directly to the data acquisicion facility located outside containment. The Data Acquisition Facility is an Accurex Audodata 10/50 system, which interfaces with the IBM System 9000 Benchtop computer and is used to scan all 58 channel inputs at specified intervals. Scanners have the following specifications:

Accurex 1061-31 Ten Channel, 3-Wire Scanner Input Range:

-10 to +10 VDC Accuracy:

1 0.005% Full Scale, t 0.005% Reading, t 0.000025 VDC @ 20 to 30'C using High Resolution Output Sensitivity:

1 0.002% FS Accurex 1061-51 Ten Channel, 5-Wire, Resistance /RTD Scanner Input Resistance Range:

5000 Accuracy: 1 0.005% Range, t 0.015% Reading, t 0.0250 @ 20 to 30'C using High Resolution Sensitivity:

1 0.01 0 (1 0.05'F) 4

5.-

Flow Instrumentation i

A turbine flowmeter was used'to impose the leak during the verification test.

The flowmeter used was a Flow Technology Model FTC-8C5.0-GJS Flocapsule with Model PRI-402A Flow Rate Monitor, with the following specifications:

Range:

0.5 to 5 ACFM Repeatability: i 0.25% FS (1 0.0125 ACFM)

Accuracy:

1 0.2%, traceable to NBS Output:

Visual display plus 0-5 VDC signal for recording 6.

Instrumentation Selection Guide (ISG) Calculation The Instrumentation Selection Guide is an acceptable method to verify the ability of the instrumentation system to measure the containment integrated leakage rate. The ISG formula is described in American National Standard ANSI /ANS-56.8-1987.

The maximum allowable value for the ISG is 0.25 L, or

' 05%/ day for Catawba.

The ISG calculated for this test A-hour duration) was 0.0105%/ day. The ISG calculated i

for an 8-hour duration was 0.0316%/ day.

C.

Description of Computer Program 1

The ILRT System program is designed specifically to integrate the i

]

Accurex Autodata Ten /50 data acquisition system with the IBM System 0000 Benchtop computer for the calculation of leakage, with as little

}

operator intervention as possible. Test parameters to be measured are pressure, dewpoint temperature, and dry bulb temperature inside i

the containment.

Instrument readings by the data-acquisition system j

are recorded on the hard disk of the System 9000. From this data, the leak rate is calculated by the computer and displayed on the computer monitor. Use of the absolute pressure method as described in ANS N45.4-19.'2 is the basis for the leakage calculations performed by the ILRT Syv..em program. The primary methodology is mass plot analysis as described in ANSI /ANS 56.8-1981.

The secondary j

]

methodology is the total time calculation as described in BN-TOP-1.

A description of the calculations performed is given in Appendix A.

i n

I 4

i i

i 5

1 i

l i

The ILRT System program is executed using the multi-tasking facilities of the System 9000. This system allows the data acquisition to take place independent of the calculations. There are two tasks running concurrently.

These are the Data Acquisition Task (DAT) and the Calculation Task (CALC). The majority of the calculations are done by DAT, while CALC is used primarily to perform the least squares regression of the data and to print reports and graphs.

DAT is the program that controls the data acquisition system.

Dependent on the specified interval, DAT sends a signal to the Accurex to scan the channels for the data. The data is then sent to the 9000 and stored on disk. As the data is received, it is checked for validity. The validity check is performed by checking the variances of the calibrated temperatures in each building fraction.

Any value that is greater than or less than a specified amount from the average for containment or any compartment thereof is flagged, and a warning is printed on the System 9000 printer immediately following the data set.

DAT also performs all the calculations required to determine the total air mass in containment at any given time. The test elapsed time and corresponding air mass are also stored on hard disk by DAT.

CALC is the program that performs the least squares regression fit on the mass / time data. The operator must demand the calculations be l

performed by CALC.

D.

Description of Pressurization Equipment Pressurization for the Catawba Unit 1 ILRT was accomplished using two oil-free diesel-driven air compressors, each having a rated capacity of 1500 cfm at 150 psi. The compressed air, after passing through water-cooled af tercoolers and refrigerant air dryers, was i

i routed to the discharge header of the instrument air system compressors. The air was then injected into Lower Containment and into the Ice Condenser via normal station / instrument air penetrations.

(The air injected into the Ice Condenser was first passed through a Desiccant Air Dryer to further reduce the dewpoint prior to injection into the 15'f Ice Condenser Region.)

6

III. TEST RESULTS A.

Description of the Testing Sequence During the Unit 1 E00-2 refueling outage, several modifications were made to containment penetrations.

Namely, spare penetrations M141, M234, and M452 were converted to Type-B penetrations (flanged both inside and outside of the Containment Vessel) to allow equipment access during the present and future refueling outages. Also, as part of the Upper Head Injection (UHI) System deletion, M406, M407, and M454 piping penetrations were cut and seal-welded closed. An As-Found Type C Test was performed on the UHI valves prior to their removal, and a Structural Integrity Test as required by ANSI N45.4-1972 was performed on the welded penetrations prior to ILRT.

The majority of the Type B and C local leakage rate testing was completed prior to the Type A test. As required by IE Information Notice 85-71, both As-Found and As-Left leak rate tests were performed on Type B and C penetrations which were repaired or modified during the refueling outage. A tabulation of the Leakage Savings resulting from this testing can be found,in Appendix E.

In addition to the installation of the data acquisition system and instrumentation, preparation for the ILRT included inspections of the interior and exterior surfaces of both the Containment Vessel and the Reactor Building. The inspections, performed by Duke Power Company Design Engineering / Civil Group, were completed on 11/20/87.

Another test prerequisite was the performance of a temperature survey, required by both ANSI N45.4-1972 and ANSI /ANS-56.8-1987 to verify the proper location of the RTDs in containment. The temperature survey was performed per Procedure TT/1/A/9100/42, and was satisfactorily completed on 11/22/87.

In order to provide air to the seals on the Personnel Air Locks inner doors and the Ice Condenser doors while instrument air to containment is isolated for the ILRT, a portable electric compressor is placed inside containment. During the installation of the compressor for this test, it was discovered that one of the Ice i

Condenser equipment access door seals leaked excessively, causing the small electric compressor to run constantly.

(NOTE: The Ice condenser door seals are not part of the containment pressure boundary, as are the Airlock door seals, but rather provide a boundary between the cold air inside the Ice Condenser and the warmer containment air.) Due to the high probability of compressor failure due to overuse during the test (and a resultant loss of the Personnel Air Lock inner door seals), and due to the length of time required to replace the Ice Condenser equipment access door seal, a j

new portable electric compressor was purchased and utilized solely j

to provide air to the leaking door seal.

i 7

Operations alignment of containment penetrations was completed on 11/24/87, and pressurization of the Containment Vessel commenced at 0900 hours0.0104 days <br />0.25 hours <br />0.00149 weeks <br />3.4245e-4 months <br /> on 11/24/87.

(A list of the containment penetrations not exposed to test pressure can be found in Appendix D.)

The average pressurization rate was approximately 2 psi / hour.

Pressurization was secured at 1715 hours0.0198 days <br />0.476 hours <br />0.00284 weeks <br />6.525575e-4 months <br /> on 11/24/87, at which time the temperature stabilization phase was started. During the temperature stabilization period, a soap bubble test was performed on all hot mechanical penetrations as required by Catawba Technical Specifications.

Also, leakage survey teams were dispatched to search for any leakage paths from containment. No significant leaks were identified.

The temperature stabilization criteria of ANSI /ANS-56.8-1987 were met at 2120 hours0.0245 days <br />0.589 hours <br />0.00351 weeks <br />8.0666e-4 months <br /> on 11/24/87, at which point the ILRT was initiated.

After 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of data accumulation, all acceptance criteria were met using the Mass Plot method and the ILRT was 3

officially terminated at 2122 hours0.0246 days <br />0.589 hours <br />0.00351 weeks <br />8.07421e-4 months <br /> on 11/25/87.

Following a containment air sample by Health Physics, an attempt was made to superimpose a leak through the Containment Air Release and Addition penetration at 2240 hours0.0259 days <br />0.622 hours <br />0.0037 weeks <br />8.5232e-4 months <br /> on 11/25/87. However, no air flow was obtained through the turbine flowmeter. After approximately eight hours of troubleshooting (including an entry into containment to verify the penetration valve alignment), it was determined that one of the two containment isolation valves was not passing flow.

(Subsequent disassembly of one of the valves following the ILRT revealed the valve diaphragm, which had been replaced earlier in the outage, to be installed incorrectly.)

It was decided to move the turbine flowmeter to another location. The-flowmeter was connected to tubing from a contair. ment pressure transmitter (one of the permanent containment pressure transmitters, independent of the ILRT pressure instrumentation), and a leak was successfully imposed on the Containment Vessel at 1122 hours0.013 days <br />0.312 hours <br />0.00186 weeks <br />4.26921e-4 months <br /> on 11/26/87.

At 1535 hours0.0178 days <br />0.426 hours <br />0.00254 weeks <br />5.840675e-4 months <br /> on 11/26/87, the verification test was terminated with successful results, and depressurization of the containment vessel was initiated at 1620 hours0.0188 days <br />0.45 hours <br />0.00268 weeks <br />6.1641e-4 months <br />.

The rate of depressurizaticn was limited due to the unavailability of two 4" Containment Air Release and Addition penetrations.

(Two diaphragm valves had been improperly assembled during the outage.) Also, negligible airflow was obtained through the deflated seals of the Upper Personnel Air Lock due to the tight fit of the inner door.

(Even with the door seals completely deflated, there was minimal clearance between the door and the door frame.) As a result, the average depressurization rate was limited to less than 1.5 psi / hour, and 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> elapsed before the Containment Vessel was completely depressurized.

Containment was opened for the continuation of outage activities at 0430 hours0.00498 days <br />0.119 hours <br />7.109788e-4 weeks <br />1.63615e-4 months <br /> on 11/27/87.

8

~

r No equipment damage was found during_the post-ILRT containment inspection, except for a few broken light bulbs. There were no instrumentation failures during the performance of the test, t

]

B.

Analysis and Interpretation 1.

Temperature Stabilization Containment ventilation fans were run during pressurization to aid in mixing the containment air. Due to the cool ambient conditions, the approximate average compartment temperature rise during pressurization was only 2.5'F.-

As a result, containment temperature stabilized rapidly, and the stabilization criteria of ANSI /ANS-56.8-1987 were met within the minimum four hour period.

2.

Pressure Decay (24 Hour) Test 3

Due to the highly stable conditions inside containment following the temperature stabilization period, coupled with the leak-tightness of the containment penetrations (no significant leaks were found by the leakage, survey teams), the 95% Upper Confidence Limit Mass Point Leakage Rate was well below the acceptable limit after only five hours of data 4

accumulation. However, in order to meet the code requirements, 1

the test was conducted for a duration of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

The results were as follows:

Measured Leakage Rate:

0.0457%/ day 95% UCL Leakage Rate:

0.0508%/ day As-Found Leakage Rate:

0.0614%/ day (95% UCL + Leakage Savings

+ Leakago Penalty)

As-Left Leakage Rate:

0.0522%/ day (95% UCL + Leaksge Penalty)

Acceptance Criterion:

0.15%/ day (75% of L,)

i j

Plots of data accumulated during the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> test reveal relatively smooth, predictable trends, with the exception of perturbations occurring at approximately 12.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> and again at 14 hours1.62037e-4 days <br />0.00389 hours <br />2.314815e-5 weeks <br />5.327e-6 months <br /> into the. test. The transient are noticeable on the Mass Point Leskage Rata plot, as well as on the pressure and temperature plots for each of the three compartments. The most plausible explanation for the perturbations could be one 1

or both of the following:

(1) Due to its almost continuous operation, the portable electric compressor supplying the 1

leaking Ice Condenser equipment access door seal was tripping on thermal overload. This allowed the seal to deflate i

completely (causing a pressure / temperature spike), which in turn allowed the warmer air from Upper Containment to migrace into the Ice Condenser.

(2) Some of the Ice Condenser Air Handling Units were beginning to frost, causing their respective l

8 9

i 2

fans to trip off.

(These units were later put in manual.

defrost mode and the fans subsequently restarted.) Both of j

these explanations are supported by the following two facts-(1) The pressure and temperature spikes are more pronounced on the Upper Containment plots than on the Lower Containment plots.

(2) The Ice Condenser average temperature started to 1

increase rapidly at 12.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> into the test. Several hours later, tLe rate of temperature rise was decreased when some of the Air Handling Units fans were restarted. Although the Ice Condenser average temperature was never returned to its original low value, conditions elsewhere in containment restabilized, and the Mass Point leakage rate trend returned to essentially a horizontal line.

It may be worth noting that although the measured leakage using the Total Time Method was acceptable after 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> of data accumulation, the 95% UCL leakage using the Total Time Method (with BN-TOP-1 short duration acceptance criteria) did not meet the acceptance criterion until 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> into the test.

3.

Superimposed Leak Rate Test A superimposed leak equivalent to 0.1989%/ day was added to the existing containment leakage using the turbine flowmeter.

After 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> and 10 minutes of data accumulation, the t

verification test was terminated with the following acceptable results:

Minimum acceptable Measured Leakage Rate:

0.1946%/ day (24-Hour Test Measured Leakage Rate + Superimposed Leak Rate - 25% of L )

Maximum acceptable Measured Leakage Rate:

0.2946%/ day (24-Hour Test Measured Leakage Rate + Superimposed Leak Rate + 25% of L,)

i Measured Leakage Rate during Verification Test:

0.2701%/ day It should be noted that during the 14 hour1.62037e-4 days <br />0.00389 hours <br />2.314815e-5 weeks <br />5.327e-6 months <br /> delay between the end of the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> test and the beginning of the superimposed leak rate test, the Mass Point leakage rate increased slightly (due to a Health Physics sample, an entry into containtsent, and various troubleshcoting). However, even if the measured leakage rate after 38 hours4.398148e-4 days <br />0.0106 hours <br />6.283069e-5 weeks <br />1.4459e-5 months <br /> were substituted for the measured leakage rate after 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> in the above acceptance criteria, the results of the supplemental test are still within the i 0.25 L acceptance limits. Also, since the measured leakage rates at*24 hours and 38 hours4.398148e-4 days <br />0.0106 hours <br />6.283069e-5 weeks <br />1.4459e-5 months <br /> were the minimum and maximum leakage rates, resp., in that 14 hour1.62037e-4 days <br />0.00389 hours <br />2.314815e-5 weeks <br />5.327e-6 months <br /> time span, the acceptance criteria were met for all measured leakage rates between 24 and 38 hours4.398148e-4 days <br />0.0106 hours <br />6.283069e-5 weeks <br />1.4459e-5 months <br />.

I i

10 u

d

IV. FIGURES A.

Temperature Stabilization Plots I

The attached plots show data accumulated during the four hour temperature stabilization period, beginning at 1720 hours0.0199 days <br />0.478 hours <br />0.00284 weeks <br />6.5446e-4 months <br /> and ending at 2120 hours0.0245 days <br />0.589 hours <br />0.00351 weeks <br />8.0666e-4 months <br /> on 11/24/87.

Normalized Containment Mass Lower Containment Pressure Lower Containment Avg. Temp.

Lower Containment Vapor Pressure Upper Containment Pressure Upper Containment Avg. Temp.

j Upper Containment Vapor Pressure j

Ice Condenser Pressure

]

Ice Condenser Avg. Temp.

l 1

Ice Condenser Vapor Pressure l

3 i

j

~

f f

i i

i i

l l

l i

(

)

i l

i i

i 1

3 j

11 l

4

}

NORMALIZED CONTAINMENT MASS CATAWBA NUCLEAR STATION UNIT 1 1.o018 L

v4 1.0012 3

N

{

s. coos U) s.ooo4 U)

<t I

~

s.occo o

w N

o. sees

~

H

_J

<t 1

X E

O Z

o. sees o.seS4 -

1

~

i 1

l l

o.saso 1

2-3 4

1 l

TIME (HOURS)

L su w w n a m m m - u m m.

LOWER CONTAINMENT PRESSURE CATAW8A NUCLEAR STATION UNIT 1 2s.7oo 1

as.s7o :

~

as.s4o 2

as.sso

~

H in b

as.seo

~

W I

E D

as.sso En (n

as.sao g

a

~

l as.4so l

as.4so as.4m 1

I I

i as.4oo 1

2.

3 4

5 TIME (HOURS) 11/24/87 17: 20: 19 TO 11/24/87 21: 20: 14

l LOWER CONTAINMENT AVG.

TEMP.

CATAWBA NUCLEAR STATION UNIT 1 so.oo 7s.so lL 7s.oo 09 W

o 7e.so W

E 7e.oo D

F-4 m

77.50 W

O_

77.0c x

h 4

.x 75.00 4

7s.so 3,, -

1 I

I i

1 2

3 4

5 TIME (HOURS)

--- -------- - Atz2MB7 Juz-rzoustar61 stua vzrmtmemm--

LOWER CONTAINMENT VAPOR PRESSURE CATAWBA NUCLEAR STATION UNIT 1 o.4ooo.

~

o. moo o.asoo

<t H

m o.34oo 1

o.saoo

~

T0 W

o. moo W

LLI l

o.aeoo a

T

~

O o.aeoo CL

<t

~

o.a400

~

o.aaoo I

I I

- - - - - I

~

o.rooo 1

2 3

4 5

TIME (HOURS) 11/24/87 17: 20: 19 TO 11/24/87 21: 20: 14

UPPER CONTAINMENT PRESSURE 1

CATAWBA NUCLEAR STATION i

1 UNIT 1 2s.7oo as.s7o as.sao 2

<t as.eso 1

H m

b as.sso h Lt3 E

D as.sso l

D m

tij as.sao g-Q.

i

-an.4so as.4so rs.4m l

i I

i

~

as,4eo 1

2 3-4 s

TIME (HOURS) tu24/azemsutamm-mm

.. _. _ _ _ _ _ _ _ _ _ _ _ _ _ = _ _. _. _ _ _ _.

UPPER CONTAINMENT AVG.

TEMP.

CATAWBA NUCLEAR STATION UNIT i 7s.oo 74.so li-74.00 O

W O

73 88

~

W E

~

73.oo D

H 4

E 72.So W

O_

72.oo W

71.50 o

4 71.oo 7o.so I

I i

i 7o.oo 1

2 3

4 5

TIME (HOURS) 11/24/87 17: 20: 19 TO 11/24/87 21: 20: 14

UPPER CONTAINMENT VAPOR PRESSURE l

l CATAWBA NUCLEAR STATION UNIT i 0.4000 0.3800 O.3600

<[

~

H

~

U) 0.3400 E

0.3200 g

E D

U) 0.3000 U)

~

ID 1

0.2800 g

1 2

0 0.2600 N

0-

~

<f y

0.2400 -

0.2200--

I I

0.2000 1

2 3

4 5

TIME (HOURS) 11/P4/R7 17 19 TO i i /Pd /A7 P1-20 1a

ICE CONDENSER PRESSURE 1

CATAWBA NUCLEAR STATION UNIT i i

as.7oo

~

as.s7o -

. i i

as.s o 6

<t an.sto i

H in O_

an.seo m

W T

D as.seo (n

in W

an.sao E

(L as.eso an.4eo 1

an.4m i

1 I

I i

1 2

3 4

5 l

TIME (HOURS)

+

11/24/87 17:20:19 TO 11/24/87 21:'20; 14

ICE CONDENSER AVG.

TEMP.

CATAWBA NUCLEAR STATION UNIT i 15.00 14.50

^

1 14.00 O

W C) 13.50

~

W T

~

13.00 g

F-4 E

12.50 W

O_

f 12.00

~

F-W 1s.so O

m 11.00 g>

4 10.50 -

~

l I

I i

10.00 1

2 3

4 5

TIME (HOURS)

ICE CONDENSER VAPOR PRESSURE CATAWBA NUCLEAR STATION UNIT i o.osoo e.caea o.o4eo 4

H U) s.o44o o.e429 g

E D

W o.omoo

~

E o.osea g

i E

O o.osso i

4 2

o.osso o.oseo 4

6 I

I I

i

,,,3.,

1 2

3 4

5 TIME (HOURS) 11/24/87 17: 20: 19 TO 11/24/87 21: 20: 14

B.

Pressure Decay (24 Hour) Test Plots The attached plots show data accumulated during the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> ILRT, beginning at 2120 hours0.0245 days <br />0.589 hours <br />0.00351 weeks <br />8.0666e-4 months <br /> on 11/24/87 and ending at 2122 hours0.0246 days <br />0.589 hours <br />0.00351 weeks <br />8.07421e-4 months <br /> on 11/25/87.

Mass Point Leakage Rate and UCL Normalized Containment Mass Lower Containment Pressure Lower Containment Avs. Temp.

Lower Containment Vapor Pressure Upper Containment Pressure Upper Containment Avg. Temp.

Upper Containment Vapor Pressure Ice Condenser Pressure Ice Condenser Avg. Temp.

Ice Condenser Vapor Pressure

MASS POINT LEAKAGE RATE AND UCL CATAWBA NUCLEAR STATION UNIT 1 o.3oo f

7' MEASURED o.24o 4

O N

UCL o.2 o M

W 1 I\\

0.soo

~

i*1 Ii 1

' )

1 0.75La 11.1 Le o.15e e

g I

L )

T

~

j\\

o.12o 1

, 1,-

\\ -T, }

11J i*

L9

  • /

4 o.oso y

4

,/

~

,- s -~ m 11.,

,!ifVV'x-T,[

T' j - d',N. -- s,_,____, h,-

~

-m -

~

J o.ooo j

%. " ~.

tj

~

I f I

o.om

~

i

,,,b I

I I

I I

I I

I I

I I

_8 1

1 1

I I

I I

I I

I l

t 2

3 4

5 6

7 o

9 to 11 12 w 14 15 18 17 to SS 2o 21 22 23 24 25 TIME (HOURS) a unveouxamsvt mansn w.s

NORMALIZED CONTAINMENT MASS CATAW8A NUCLEAR STATION UNIT i s.ooao 1.0016 e

1.0012 3

2 N

1.0008 3:

U) 1.0004 U)

<t 1

~

1.0000 O

LLI N

0.9996 H

J

[

0.9992 g-O Z

0.9988 --

0.9984 l

I I

I I

I I

I i

i l

l I

I I

I I

l l

1 l

l l

1 a.998o 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 17 18 19 20 21 22 '23 24 25 TIME (HOURS) 11/24/87 21: 20: 14 TO 11/25/87 21: 22: 16

LOWER CONTAINMENT PRESSURE CATAWBA NUCLEAR STATION UNIT 1 29.500 29.480 29.460

<t 29.440 H

m S

29.420

~

tu E

D 29.400 W

m 29.380 O_

23.360 -

29.340 -

29.320 l

i I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I 29.300 i

2 3

4 5

6 7

8 9

10 '11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 TIME (HOURS) 11/24/87 EL-PJor 14LJffm 51RbMvffn7/ pst PJP-sls

LOWER CONTAINMENT AVG.

TEMP.

CATAWBA NUCLEAR STATION UNIT 1 7s.00 :

77.50 2

1 77.00 O

Lij O

76.50 LtJ E

76.00 D

I--

E 75.50 a

=

75.00

~

LtJ 74.50

-O

<I 74.00 2

<C 73.50 -

1 I

I I

I I

I i

1 I

I I

I I

i i

I l-I l'

I I

I 73,oo i

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 TIME (HOURS) 11/24/87 21: 20: 14 TO 11/25/87 21: 22: 16

LOWER CONTAINMENT VAPOR PRESSURE CATAWBA NUCLEAR STATION UNIT i

,,3,,,

o.asoo o.26oo

<t H

W o.2400 1

o.2200 g

T D

W o.aooo W

W T

o.1ooo a

E O

o.16co 1

<C o.14oo o.12co -

1 I

I I

I I

I I

I I

I I

i 1

l l

l l

l l

g o.1oco 1

2 3

4 5

6 7

8 9

to 11 12 13 14 15 16 17 18 19 2o 21 22 23 24 25 TIME (HOURS)

-mm m_mm,- en

e. em

UPPER CONTAINMENT PRESSURE CATAWBA NUCLEAR STATION UNIT 1 2s.500 as.4ao as.4so

<t 29.440 H

m b

29.420 L1J E

D 29.400 W

W 2s.380 1

as.aso 1

as.340 29.320 1

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I 29.300 i

2 3

4 5

s 7

8 9

to 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 TIME (HOURS) 11/24/87 21: 20: 14 TO 11/25/87 21: 22: 16

UPPER CONTAINMENT AVG.

TEMP.

CATAWBA NUCLEAR STATION UNIT i 73.00 72.50 m

ll-72.00 O

tt)

O 71 50 lij 1

71.00 D

V-

<t E

70.50 Lt]

Q_

70.00 l-

~

Lil 69.50 O

<t 69.00 --

<C Es.50 -

i i

l l

l 1

l 1

l l

1 1

I I

I I

I I

I I

I I

I I

1 2

3 4

5 6

7 8

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 TIME (HOURS)

A l/2A18 L 231*JA* R6\\ Eld \\ M A W M 2D*##~**

UPPER CONTAINMENT VAPOR PRESSURE CATAWBA NUCLEAR STATION UNIT 1 o.3000 o.2eoo o.asoo

<t H

W o.2400 Q-

~

o.2200 g

E J

W o.aooo W

111 f

o.ieoo

~

E O

o.isoo O_

<t o.14oo p.1200 I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I o.iooo i

2 3

4 5

6 7

8 9

to 11 12 13 14 15 15 17 18 19 2o 21 22 23 24 25 TIME (HOURS) 11/24/87 21: 20: 14 TO 11/25/87 21: 22: 16

ICE CONDENSER PRESSURE CATAWBA NUCLEAR STATION UNIT i 29.500 29.4e0 29.460

<t 29.440 H

_~

w b

29.420 Lij E

D 29.400 U3 W

29.3s0 Q_

29.360 29.340 29.320 -

2,,3o,-

1 I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I i

1 2

3 4

5 6

7 8

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 TIME (HOURS)


m-mmm -

ICE CONDENSER AVG.

TEMP.

CATAWBA NUCLEAR STATION UNIT i 17.00 is.50 16.00 O

[1]

l O

15.50 LIJ E

2-15.00 g

F 4

E 14.50 tij O_

14.00 LL]

13.50 0

[

13.00 4

12.50 1

I I

I I

I I

I I

I I

I I

I I

I I

i l

1 I

I I

i gg,oa 1

2 3

4 5

6 7

8 9-10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 TIME (HOURS) 11/24/87 21: 20: 14 TO 11/25/87 21: 22: 16 L

ICE CONDENSER VAPOR PRESSURE CATAWBA NUCLEAR STATION UNIT i o.osoo o.o4eo o.o4so

<t Hm o.o440 O_

o.o42o g

E o.o400 m

L1J

[

o.oseo E

O o.oaso Q-

<C o.o34o o.o32o i

I I

I I

I I

I I

I I

I I

I I

I I

I I

l l

l l

l

,,,3 o

1 2

3 4

5-6 7

8 9

to 11 12 13 14 15 15 17 18 19 20 21 22 23 24 25 TIME (HOURS) 11/2AB17LPLkPXLM1.1@UUVlP&v2(WL PLW P&2* %8

C.

Superimposed Leak Rate Test' Plots The attached plots show data accumulated during the verification test, beginning at 1125 hours0.013 days <br />0.313 hours <br />0.00186 weeks <br />4.280625e-4 months <br /> and ending at 1535 hours0.0178 days <br />0.426 hours <br />0.00254 weeks <br />5.840675e-4 months <br /> on 11/26/87.

Mass Point Leakage Rate and UCL

' Normalized Containment Mass l

d l

l

-m

MASS POINT LEAKAGE RATE AND UCL CATAWBA NUCLEAR STATION UNIT i 0.800 0.700 MEASURED 0.600 4

[s N

o UCL 2-

/

o.500

,o R

s

[

\\,/,N 3

0.400

\\

v

N ACCEPTANCE e'

'- ^ -

LIMITS o.300 j

-N ~ - ~ ------. y ~. -

g

~ ' -

W l

~. j "

4 O'

l

./

o.200

/

W

/

CD

/

<t 0.100 y

4 W

/

d o.000

/

-0.100 I

I I

I

-0.200 1

2 3

4 5

TIME (HOURS) 11/26/87 11: 25:

4 TO 11/26/87 15: 35: 52

NORMALIZED CONTAINMENT MASS CATAWBA NUCLEAR STATION UNIT i 1.0020 1.0016 w

1.0012 3

_~

N 1.0008 (f) 1.0004 i

(f) 2

<t 1.0000 o

M tu

^

'N 0.9996

^

H

_J 0.9992 q

O

^

1 Z

0.9988 -

0.9984 -

0.9980 1

2 3

4 5

TIME (HOURS) 11/26/87 11: 25:

4 TO 11/26/87 15: 35: 52

~

D.

Miscellaneous Plots

?

The attached plots show:

(1) Mass Point Leakage Rate and (2) Normalized Containment Mass from the beginning of the ILRT.

(Pressure Decay Test) to the beginning of the Superimposed Leak Rate Test, and (3) Upper Containment Pressure and (4) Ice Condenser Average Temperature from the start of pressurization to the end of depressurization.

8 P

f s

l l

l i

l

MASS POINT LEAKAGE RATE AND UCL CATAWBA NUCLEAR STATION UNIT 1 0.300 b

"~*7 MEASURED 0.240

<t c1

)

UCL 0.210

_ i a

_ ig I

o.180

,,.e i.

_ i ii

_ r 3 0.75La to 0.150 s -

g

<f E

i

.o.120 LLI CONTALMMENT ENTRY 0.090 y

4

[

g e\\

24 MA LJt.C Tf4Pt4NAThD,"

'^-,%

N.t' A6M SAMPLC V'

v N'

~ s _

o.06o i

-.- u _

a w-7 l

II

  • " "'" NY o.o30 ssrATTittrT TO IMPO LCD I

sufTKsMPoss LCAK LEAK

-1 I I I i l iI I I I 1 1 I I I I I I I I I I I I I I I I I I I I I I I I i 1 2 3 4 5 6 7 8 9 to 111213141516171819 20 2122 23 24 25 26 27 28 29 30 3132 33 34 35 36 37 38 39 TIME (HOURS) eaomo m m m e m m - m m

NORMALIZED CONTAINMENT MASS CATAWBA NUCLEAR STATION UNIT i 1.0020 1.0016 1.0012 3t N

{

1.0008 (f) 1.0004 in

<t 1.0000 O

lij N

0.9996 H

_j 0.9992 m

O

_~

Z 0.9988 0.9984 l l I I I I I I I I I i 1 1 1 I I I I I l l l l l _I I

l' 1 l l l l l_ l l l l 0.9980 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 TIME (HOURS) 11/24/87 21: 20: 14 TO 11/26/87 11: 25:

4

UPPER CONTAINMENT PRESSURE CATAWBA NUCLEAR STATION UNIT i 34.000 32.000 30.000 hA h 0

  1. l C

4 28.000 H

[

m b

26.000

_~

A unraniunt STAGou tkrnon g-s encssuec occay -rr.s r D

24.000 C = vce recAvsors TEsr m

W 22.000 CL 20.000 18.000 16.000 1111 I I I !_! ! 111111111111 U 1111 l l 111111 I 111111111 l l 11111 l_11 I t i l l l l l I l l

,,,ooo 12 3 4 5 6 7 8 910L 212134SS71STEE22eTtERIE905825345MBBIB980898213:485864W8895G552535458551555533455559 TIME (HOURS) ct re

ICE CONDENSER AVG.

TEMP.

CATAWBA NUCLEAR STATION UNIT i 20.00 19.00 1

18.00 C

W i

O 17.00 Lu 16.00 h

ANu's Mar ## stAmuAL DErdoi7" 4

FAMC RLSTA RTEb d

E 15.00 Lu I,

STAEtT Q

DiritLC$uRs2tNG

~j 14.00

[d PatsssuciaArson g_

COMPLCTC ld 13.00

.6 C

2 Auu*s FRosrsna 12.00 --

CAWING l'ANC To T#f fWo6ttns wrrn LEAvsNG

^

Door SCAL 11.00 1 1 I I I I I I I I I i 1 1 I I I I I ljjj i i 1 1 l l l 1 l 1 1 l l l l l l l l l l l l l l j i i g i g g g,,,, ; ; i,,,,,

10.00 i 2 3 4 5 6 7 8 9 im11a34SS718!EE2234 TERE 9KBB3345mmgag33msgAME5533mmungge TIME (HOURS) i1/24/87 8: 35: 30 TO 11/27/87 5:

1:

9

i i

V. APPENDICES

'I A.

Leak Rate Calculations Description B.

Test Log of Significant Events C.

RTD Locations j

D.

Leakage Penalty Analysis E.

Leakage Savings Analysis t

F.

Local Leakage Rate Testing Conducted Since the Last ILRT G.

Test Data l

1 i

6

't t

l I

i i

h h

i

e APPENDIX A LEAX RATE CALCULATIONS DESCRIPTION I

1 l

l l

l

SYMBOLS AND DEFINITIONS A

- Slope of least squares line B

- Intercept of least squares line L*

- Maximum allowable leakage rate at calculated peak accident pressure as specified in the station's technical specifications, (wt. %/ day)

L"" - Estimate of leakage rate, derived from Mass Point least squares slope and intercept, expressed as a positive number, (wt. %/ day) l L

- Measured leakage rate based on the difference i

between the initial mass at time t and the mass at y

time t (wt. %/ day) i, LTT - Estimate of leakage rate, derived from the Total Time least squares slope and intercept, (wt. %/ day)

I n

- Number of (N,ty) or (L,tti) pairs of measurements 1

i N

- Normalized mass of containment air at time t g

1 P

- Total compartment absolute pressure in containment, (psia)

P

- Partial pressure of water vapor, (psia) y R

- Gas constant for air, 53.35 ft Ibf/lbm 'R S

- Estimate of standard deviation of slope term A g

derived from least squares line T

- Mean compartment absolute temperature of containment air, (*R) t

- elapsed time since first reading, (min) t ttg - elapsed time since second readinc, (min) t.95-95th percentile of Students t distribution F

UCL - Upper Confidence Limit; a calculated value constructed from test data with the intention of placing an upper bound on the time leakage rate, (wt. %/ day)

V

- Internal free volume of containment (asgumed to remain constant for test duration), (ft )

W

- Measured mass of containment air at time i g

i 1

- subscript i indicates ith data point; i.e., (W,tt),

1 1 = 1,2,...,n A-1

1.0 RAW DATA CALCULATIONS The raw data set consists of test time, air temperature readings in ohms, pressure readings in volts and dew point temp-erature readings in millivolts.

Catawba and McGuire use 52 RTD's for temperature measurement, three Ruska's for pressure measurement and six sensors for dew point temperature measurement.

Oconee uses 24 RTD's for temperature measurement, two Ruska's for pressure measurement and six sensors for dew point temperature measurement.

All raw data values are converted to the appropriate units by equation 1.1.

Y = A + BX + CX2 (1,1) where:

Y = converted value

('F, psia)

X = raw data value (ohms,V,mv)

A,B,C = conversion constants Note:

For Pressure A & C = 0.0, B = 10.0.

For Dew Point A,B & C are obtained from manuf.

instrument specification sheet.

For Temperature A,B & C are obtained from Standard's Lab calibration sheets.

The dew point temperature is substituted into either equation 1.2 or equation 1.3 to calculate the partial pressure of water vapor.

For T > 32*F :

(1.2) 5 l

E k (1 - 0)"

n l

Py 1

n=1 (1 - 0) l

= exp l

P

'O1+

6(1 - 0) + k (1 - 0):

k (1 - 0)2 +k c

7 8

g-A-2

where:

P

= vapor press. (Pa) k3 = -168.1706546 y

~4 (1 Pa = 1.45037738 x 10 psi)

P

= 22120.0 kPa k4 = 64.23285504 c

0

= T/T k5 = -118.9646225 c

T

= dew point temp. (*K) k6 = 4.167117320

(*K = (5/9)(*F - 32) + 273.15]

T

= 647.3 'K k7 = 20.97506760 c

9 kg = -7.691234564 k8 = 1 X 10 k2 = -26.08023696 kg=6

Reference:

ASME Steam Tables, Fifth Edition, Appendix 1, Section 5, Reduced Saturatio,n Pressure, 1983.

For T 5 32 *F :

(1.3)-

2 + C *T + C *T2 + C *T3

  • C *T

+ C *1n(T)

In(Py) = C /T + C 1

3 4

5 6

7 where:

P

= vapor press. (Pa)

C4 = 0.62215701 x 10 y

~4 (1 Pa = 1.45037738 x 10 psi)

T

= dew point temp. (*K)

C5 = 0.20747825 x 10

(*K = (5/9)(*F - 32) + 273.15)

-12 Cy = -5674.5359 C6 = -0.9484024 x 10 C2 = 6.3925247 C7 = 4.1635019

-2 C3 = -0.9677843 x 10

Reference:

ASHRAE Handbook 1981 Fundamentals, Chapter 4, page 2.

A-3

The average temperature for each compartment at time i is determined by equation 1.4.

1 l

T

=

g (1.4) l

$b I

j=n Tg3 where: T

= average temperature for compartment at g

time 1,

('F)

T temperature recorded by sensor j at 13 = time i, (*F)

X)m==volumefractionassignedtotemp.sensorj n

lower and upper bound on temp. sensors in compartment

Reference:

Draft Regulatory Guide MS 021-5, position 15.

The average partial pressure of water vapor for each compartment at time i is determined by equation 1.5.

m Pv

=E Pvt 3*X3 (1.5) t j=n where: Pv

= average partial pressure of water vapor for 1

compartment at time i, (psia)

Pv ) = water vapor pressure recorded by sensor j i

at time 1, (psia)

X)m = volume fraction corresponding to sensor j n

= lower and upper bound on dewpoint sensors in compartment The average absolute pressure for each compartment at time i is determined by equation 1.6.

m P

=

i E Pij*X (1.6)

)

j=n 3

1 where: P

=

1 average compartment absolute pressure at time i, (psia)

P

= absolute pressure recorded by sensor j ij at time i, (psia)

X)m=volumefractioncorrespondingtosensorj a

n lower and upper bound on pressure sensors in each compartment A-4

The mass of air in each compartment at time i is determined by.

the ideal gas law, equation 1.7.

144*V*X (Pi - Pv )

k g

ik =

(1.7)

W R

T y

where:

Wik = measured mass of compartment air at time i, (lbm)

T

= average compartment temperature at time g

1,

('R; where 'R = 'F + 459.67)

P

= average compartment absolute pressure at g

time 1, (psia) average partial pressure'of water vapor for Pvg =* compartment at time 1, (psia)

X

= compartment building volume fraction k

V

= total containment vessel volume, (ft3)

R

= gas constant for air, (53.35 ft ibf/lbm 'R) 144 = conversion constant from ina to ft:

The mass is calculated for each of three compartments (lower containment, upper containment and'the ice condenser) at Catawba and McGuire Nuclear Stations.

The mass of each of the three

]

compartments is summed together, resulting in the total mass for the containment vessel. For Oconee Nuclear Station, having only'one compartment, the containment mass is equal to the compartment mass.

1 A single total containment mass and a single time is assigned to each reading set number.

The mass for each reading is normalized by dividing the mass corresponding to each reading by the mass corresponding to the first reading at time t y.

Normalizing the containment masses for each reading improves the precision of the leakage rate calculations by reducing the truncation errors associated with the large numbers generated by 4

the least squares fit regression calculations.

I A-5 4.

.m.-

- - ~. - -

l The normalization equation is given by 1.8.

Wi Ng=

(1.8)

W1 where:

N total normalized containment mass at time i Wk==totalcontainmentmassattimei Wy = total containment mass at time 1 2.0 Mass Point Leakage Rate Calculation This analysis method consists of determining the mass of air in containment, absolutely, utilizing the ideal gas law, at each time point during the test and using a straight-line least squares analysis to estimate the leakage rate.

The estimate of the leakage rate is a function of both the slope and the intercept of the regression line computed by equations 2.1 and 2.2 respectively.

n(Et Ng '4) - (EN )(Etg) g A

=

(2.1) n(Et 2)

(Ety)2 g

(EN )(Et a) - (Et N )(Ett) g g

tt

(.2) n(Ett)

(Ety)2 a

where: A

= slope of least squares line B

= intercept of least squares line t

= elapsed time since first reading,(min)

N{j = normalized mass of reading at tpairs)g (Ng = W y

n

= number of points (N, t g

g Note:

Each t is the elapsed time between the clock time atwhibhthefirsttestreadingistakenandthe clock time at which the ith reading is taken.

Thus, t1 = 0 in all test situations, t is the elapsed time before the next reading, a,nd so on.

l i

i A-6 i

The measured leakage rate is expressed as the ratio of the rate of change of mass to the mass in containment at time t1 = 0.

Since values of t are expressed in units of minutes, the mass 1

point leakage rate is expressed as a positive number by computing equation 2.3.

L,= -144,000.0*(A/B)

(2.3) where:

L** = estimate of leakage rate, derived from least squares slope and intercept, (wt. %/ day)

A

= the slope of the least squares line B

= the intercept of the least squares line

-144,000 = (60 min /hr)(24 hrs / day)(100 %)

i The standard deviation of the slope, s, is given by 2.4.

g n(EN a)

(EN )2 1/2 g=

( 1) (

f 1

S A2)

(2.4) n-2 n(Et 2)

(Ett)2 1

where:

Sg== standard deviation of the slope A slope of the least squares line A

i = normalized mass of reading at t N

WN)

N 1==elapsedtimesincefirstreadinh,,((mkn=)

y 1

t number of points (N

,t pairs) n g

g The following approximation is given for the 95th percentile of the Student's t distribution, t.95 For d 23 p

1.6449(n-2)2 + 3.5283(n-2) + 0.85602 t

(2.5)

  • 9 5 = -- ( n-2 ) : + 1.2209(n-2) 1.5163 where:

t the 95th percentile of the Student's t

  • 95 = distribution n-2

= dagrees of freedom, d, where n = the number of (N

,t pair $)

1 g

Reference:

ANSI 56.8-1981, Appendix B, footnote 17,p 23.

1 i

A-7

The ratio S /B is small when compared with the ratio S /B; B

g j

therefore, an approximate upper confidence limit of the 95

)

percent confidence level on the true leakage rate is provided by equation 2.6.

UCL = L, + 144000.0(t.95}I8 /B)

(2.6)

A where:

UCL = approximate 95 percent upper confidence level on the true leakage.

L"" = estimate of leakage rate, derived from least squares slope and intercept, (wt. %/ day) t the 95th percentile of Student's t distribution S{95=standarddeviationoftheslopeA

=

B

= the intercept of the least squares line i

3.0 Total Time Leakage Rate Calculation J

The Total Time method calculates a series of leakage rates based on the starting mass point and the most recent mass point (i.e.

it calculates a leakage rate between data points 1 & 2; then l

a between 1 & 3; and so on).

Each successive leakage calculation is based upon a longer period of time.

The overall leakage rate in weight percent per day at any given time is determined by applying linear regression analyses to the leakage rates at each data point.

i The leak rate corresponding to each data point is determined from equation 3.1.

144,000 Li=

t1 where:

L

= measured leakage rate based on the difference i

between the initit.1 mass at time t and the mass at time t (Note: the normali ed mass at at time t =1),g(wt. %/ day) normalize mass at time t

/W )

Ny==elapsedtimesincefirsthea(Ndkn=,W(bin l

t g

i1 = 2 to n; where n = number of (N,t1 pairs) g A-8

i Plotting the measured leakage rate (L ) on the y axis and the total g

time (tti) on the x axis, the following regression equations are l

used to find the slope and intercept:

n(Ett L ) - (EL )(Ettt) i1 i

(3.2) n(Ett 2)

(Etty)2 g

( L )(Ett a) - (Ett L )(Etti) 1 g

i 1 B

=

n(Ett a)

(Etti):

g where:

A

= slope of least squares line intercept of least squares line B

=

tt = elapsed time since second reading, (min) 1 L1 = measured leakage rate based.on the difference between the initial mass at time t and the y

mass at time t (wt. %/ day) numberofpoinks, (L, tti pairs) n

=

i i

= 2 to n+1 Note:

Each tt is the elapsed time between the clock time 4

at which the second test reading is taken and the clock time at which the ith reading is taken.

Thus, 0 in all test situations, tt, is the elapsed tt

=

9 time before the next reading, and to on.

The Total Time' leakage rate at some specific time, ti, is calculated from the regression line equation for the Least Squares "best fit" straight line given by equation 3.4.

LTT = A* tty +B (3.4) wherc:

LTT = total time leakage rate at time ti, (wt. %/ day) slope of the least squares line A

=

the intercept of the least squares line B

=

tti = elapsed time since second reading, (min)

Note:

The intercept of the least squares lino, B, corresponds to the clock time for reading number two; therefore,the Total Time Leakage rate can only be calculated for reading numbers 3 to n.

A-9 i

E i,

l i

The standard deviation of the slope, S is calculated from g,

either equation 3.5 or 3.6.

For t +1 < 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />s:

(3.5) n EL a. BELT - AEL tt (tt +1 - Ett /n)a 1/2 i

i n

g g=

y( 1 + 1/n + n*

S

]

n-2 nEtt a (Etty)3 i

l For t +1 > 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />s:

(3.6) n EL a. BELi - AEL tt (tt +1'~

EU

/1 n):

1/2 f

i n

Sg=

i( 1/n + n*

]

n-2 nEtt a- (Etti):

g standard deviation of the slope'A at time _t where:

Sg== measured leakage rate based on the differenEe Li between the initial mass at time t and the mass 1

at time t, (wt. %/ day)

=slopeofkheleastsquaresline t

i A

B

= intercept of the least squares line tt = elapsed time since second reading, (min) 1= number of points (L,tti pairs) n g

i i

= 2 to n+1 The Total Time method utilizes a 97.5% Student's t distribution 3

for'a test duration less than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and a 95% Student's t I

distribution for a test duration greater than or equal to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

The approximation given by equation 3.7 is used for the I

97.5% Student's t distribution.

Equation 2.5 is used for the 95%

(

Student's e distribution.

l For t +1 < 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />s:

n 2.37226 2.82250

  • 975 = 1.95996 +

t

+

(3.7)

(n-2)

(n-2):

where:

t the 97.5 percentile of the Student's t

  • 975 = distribution l

n-2

= degrees of freedom, where n = the number of (L,tti pairs) 1 A-10

The approximate upper confidence limit on the Total Time leakage rate is given by equation 3.8.

UCL = LTT + t,S (3.8)

A where UCL = approximate 95 or 97.5 percent upper confidence level on the Total Time leakage rate, (wt. %/ day)

LTT = Total Time leakage rate, (wt. %/ day) t,

= the 95 or 97.5 percentile of the Student's t distribution at time t S

= standard deviation of Ehe slope A at time t g

n J

G l

I I

1

.i i

l A-11 i

0 APPENDIX B TEST LOG OF SIGNIFICANT EVENTS l

l l

l

Date, Time Comments 11/16/87 Containment Structural Integrity Visual Inspection started by Design Engineering personnel.

11/20/87 Containment Structural Integrity Visual Inspection completed.

11/22/87 (2045)

I&E personnel cannot place both trains of SSPS in "Test" without dropping out Source Range Reactor Trip Block.

Procedure change being written to place jumpers to avoid this situation.

11/23/87 (0300)

Portable compressor installed in containment, but not connected to Ice Condenser equipment access door seal, which is leaking excessively.

11/23/87 (0315)

Venting of Nitrogen from Cold Leg Accumulator Tanks proceeding slowly.

11/23/87 (1400)

Another portable electric air compressor is being purchased to supply air to the leaking, seal on the Ice Condenser equipment access door. Also, alternate power supplies are being pursued for the portable compressors to prevent the breakers from tripping, which would cause loss of power to the dewpoint sensors in Upper Containment.

11/24/87 (0430)

Operations completing valve alignments.

Cold Leg Accumulator Tanks almost depressurized.

11/24/87 (0830)

Containment Personnel Air Lock doors closed.

11/24/87 (0900)

Began pressurizing containment.

11/24/87 (0930)

Pressurization rate is approximately 1.0 psi / hour.

This is too slow.

11/24/87 (1000)

Found controller for Instrument Air throttle valve to containment not working properly in Auto. Took valve to Manual and opened wide open.

Instrument Air System header pressure is approximately 110 psig.

11/24/87 (1030)

Pressurization rate is approximately 1.9 psi / hour.

11/24/87 (1715)

Secured pressurization at 29.6 psia (14.92 psig). All fire alarms inside containment have alarmed due to air i

density change.

Security (Fire Panel) is being provided with hourly printouts of containment temperatures (readings from all 52 RTDs) for fire watch.

i 11/24/87 (1720)

Start Temperature Stabilization.

B-1 l

l

4 l

11/24/87 (2120)

Temperature Stabilization criteria met.

Start pressure I

decay test.

11/25/87 (0545)

Operations Shift Supervisor reported Control Room annunciator for Ice Condenser equipment access door alarming, indicating probable malfunctioning of portable i

air compressor inside containment.

11/25/87 (1350)

Transient seen in data around 0930. -Ice Condenser average i

temperature trending upward.

Checking on Air Handling Units.

t l

11/25/87 (1700)

Some AHU fans had tripped due to frosting. Had Operations f

place these AHUs in manual defrost for a while and then restart the fans.

11/25/87 (2122)

Terminated 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> ILRT.

11/25/87 (2130)

H.P. taking containment air samples.

[

11/25/87 (2240)

Attempt to superimpose leak for verification test.

Cannot get flow through Turbine Flowmeter..Now Troubleshooting penetration M204.

11/26/87 (0440)

Containment entry to verify proper valve alignment for imposed leak path, i

11/26/87 (1000)

Appears that one of the two containment isolation valves

]

(one diaphragm valve and one gate valve) is not passing i

flow. Moving flowmeter to tubing at containment pressure transmitter INSPT5050.

11/26/87 (1122)

Successfully imposed leak, i

11/26/87 (1305)

Changed data acquisition frequency from 15 minute intervals to 10 minute intervals to improve trending.

1 11/26/87 (1535)

Terminated Superimposed LRT.

4 11/26/87 (1620)

Began depressurizing containment.

11/27/87 (0230)

Unable to depressurize through penetrations M204 or M386 4

(Containment Air Release and Addition) due to CIVs not i

passing flow. Aligned the following penetrations for i

alternate vent paths (at discretion of Health Physics and Operations): M212, M331, M337, M377, M385.

11/27/87 (0250)

All fire alarms inside containment have cleared.

i 11/27/87 (0430)

Depressurization complete.

i i

r B-2 i

I i

i 1

1 l

l l

APPENDIX C RTD LOCATIONS i

E 4

5 l

k i

l 1

1 i

I l

l i

/

N o

e

\\.

HOf6 67.W IIM47 comtweer vtsan- -

n J

m.

ncactee stos.nau C#4ast MM botv st=soof @

"Su ~

"'55'"

sm.

sw.

GEN.

GEN.

9 MI'Its?A 'r'

- }

\\

/

2 t

\\

/

.g..

3 t.owt A F

g "1per f4=0

@0 O

@ g V@

I Y

@ 'V i

i

) WEV l' 8

i L-g "M ;

g f

i

. REACTORi

' VESSELj u

g Y

C-1

)

l P

o-e.

g i

J 1,

p.W g

mu y

a a

S')%

jY

]- (Ye @#r %)

GDi 9

sy e

t_(.1.?Q (CC.TT(94 WSC9 EU. %I'4' y

y a.. m.

ym 1m

. T..

.!D**'k W W-M * *'

e_, m.a m, ;w,,

p_g3.m.ip.g ;-- -" -

=. g.

7 4

4.
  • 37'4 s

M wu 3 5 W.'.

84 w

  • ~"

c.E.3.!!!EP.li c.-. 4

=.

n..

a,;=

_u.:.s

.a..liilr. 3.! E %.

~

r.=,

~~-

5..;9gygmsu.tv

~ ~ -

.x.x, 5 d52N AF M"...%'Su

...,g s w w

,,s yggg..

fc 4-4

= < -

g.,,.,,pa;i3lJE EUR ?" " "

gegy,.,;;glgg agg r= --

.e n %-

gagya;gga 5%R r"""

a

=~'

.gr.r, g,'4' *JJ;.NE".'."A.

=, 4

- w.

g.,

.g. g,g. a..

s= = =

=

= ' ' '

W.=h*I47.J."irTX%'*JM w.

W 4' EY s 5E gg U

8 C-2

,m_u___


a,

,5$

lllC c2 i

!!!!h l l l l-l i lll h hlnl $ b lI. ; 5, 5, 5, 5, 3 h

II t. inlalnllllalalalnl r

(J

. eb! nnsiiillllli ii !!!illillilillilillillillill i

ib f.

h!:igan : n : : niti: : : : : : : : : : :

3!!is!!!!!! ! ! ! ti!! ! : ij ;i !! !! ll 4 li !i !! ti li Il 1

.:... a_..

e.=........

?

eid d g

iigh

=

i li

[

I O

'I L_l 1;IHlldI h

! ll!!! !!!

4 11!!!!!.

l l

[

l i

I a

APPENDIX D LEAKAGE PENALTY ANALYSIS 1

I I

l

The following penetrations, flanges, or valves are not exposed to test pressure due to system or test alignment. Type B or C leak rate test results (minimum pathway leakage, instrument error included) are assigned to these penetrations and the total value is added to the ILRT results as Leakage Penalty.

Penetration System Reason Leakage Rate (SCCM)

M256 (INV90)

NV

  1. 1 22.0 M230 (IRN485)

BN

  1. 1 188.4 M308 (IRN430)

RN

  1. 1 11.0 M321 (1KC279)

KC

  1. 1 22.0 M221 (1WL868)

WL

  1. 1 22.0 M345 (1WL806)

WL

  1. 1 48.2 M359 (1WLA22)

WL

  1. 1 22.0 M374 (1WL321)

WL

  1. 1 22.0 M328 (1KC340)

KC

  1. 1 120.0 M204 VQ
  1. 2 22.0 M346 VY
  1. 3 11.0 CNIP-1 MIS ILRT
  1. 4 22.0 CNIP-1MI6 ILRT
  1. 4 22.0 CNIP-1MI7 ILRT
  1. 4 22.0 l

Upper Airlock IAE

  1. 5 11.0 Emerg. Air Penet, i

M372 NF

  1. 6 11.0 M373 NF
  1. 6 11.0 Upper Airlock IAE
  1. 7 22.0 Aux. Side Door Air Supply Lower Airlock IAE
  1. 7 3.0 Aux. Side Door Air Supply D-1

I

-Penetration System Reason Leakage Rate (SCCM)

M316 RF

  1. 8 0.0 TOTAL LEAKAGE PENALTY:

634.6 SCCM 6

x 2.1476 x 10

%/ Day SCCM

= 0.00136%/ Day Reasons for not aligning penetrations:

  1. 1 These penetrations contain two containment isolation valves which receive seal injection water plus a third "reverse" check valve for overpressure protection. Although the minimum pathway leakage rate for these penetrations is zero, FSAR Table 6.2.4-1 requires that the Type C LRT results of the "reverse" check valve be added to the Type A test results.
  1. 2 This penetration was the desired flowpath for the Superimposed Leak Rate Test.
  1. 3 A relief valve for the Containment Vessel was connected to this penetration.
  1. 4 These were the pressure sensing lines for the ILRT.

Pressurization fixture was installed on this penetration to allow-entry into containment.while pressurized.

  1. 6 These Glycol lines from the chillers in the Auxiliary Building to the Air Handling Units inside the Ice Condenser were required to be in service to keep the Ice Condenser cool.
  1. 7 These penetrations were in service to provide instrument air to the seals on the Personnel Air Lock outer doors.
  1. 8 This penetration was initially vented and drained for the test, but was returned to service when it was discovered that isolating M316 also isolated Fire Protection System water to the Unit 2 Auxiliary Feedwater Pump Room. Since this would necessitate a continuous fire watch, it was decided to keep the penetration in service and add the minimum pathway leakage Type C Test results to the Type A Test.

D-2

APPENDIX E LEAKAGE SAVINGS ANALYSIS 1

i j

4 As required by IE Information Notice 85-71, both As-Found (pre-maintenance) and As-Lef t (post-maintenance) leak rate tests were performed on Type B and C i

penetrations which were repaired or modified during the refueling outage. The total Leakage Savings (which is added to the As-Left ILRT result, yielding the As-Found ILRT result) is calculated by summing the differences between the As-Found Minimum Pathway leakage rate and the As-Left Minimum Pathway leakage rate for all affected penetrations.

Below is a tabulation of the Leakage Savings realized during the Unit 1 EOC-2 refueling outage. The leakage rates listed are corrected for instrument error.

As-Found As-Left Leakage i

Min. Pathway Min. Pathway Savings 1

Penetration Reason for Testing Leak Rate (SCCM)

Leak Rate (SCCM)

(SCCM)

M301 Spare penet. (Type B),

25.0 11.0 14.0 utilized during outage M371 Ice Cond. ice blowing 22.0 11.0 11.0 penet. (Type B),

utilized during outage M394 Ice Cond. ice blowing 22.0 22.0 0

penet. (Type B),

utilized during outage Fuel Type B penet., utilized 150 11.0 139 Transfer during outage Tube

{

1 l

Equipment Type B penet., utilized 498 37.8 460.2 i

Hatch during outage e

1 M213 Containment purge penet.

20.6 6.95 13.65 l

(Type C), utilized 4

during outage l

M119 Containment purge penet.

95.25 471

-375.75 (Type C), utilized during outage l

M140 Containment purge penet.

23.05 15.25 7.8 (Type C), utilized 1

during outage i

M357 Containment purge penet.

37.55 227

-189.45 (Type C), utilized j

during outage M434 Containment purge penet.

138.0 127.5 10.5 (Type C), utilized 4

during outage E-1 4

i i

i l

As-Found As-Left Leakage i

Min. Pathway Min. Pathway Savings j

i Penetration Reason for Testing Leak Rate (SCCM)

Leak Rate (SCCM)

(SCCM) i M368 Containment purge penet.

18.85 9.5 9.35 L

j (Type C), utilized during outage M433 Containment purge penet.

77.0 131.5

.-54.5 j

(Type C), utilized j

during outage j

i M456 Containment purge penet.

79.1 62.5 16.6 (Type C), utilized j

during outage M432 Containment purge penet.

118.0 100.6 17.4 (Type C), utilized during outage l

M204 Diaphragm replacement 22.0 22.0 0

on valve IVQ16A M386

~

Diaphragm replacement 22.0 11.0 11.0 on valve IVQ2A r

i M347 MOVATS testing on 22.0 11.0 11.0 valve INV15B

M406, UHI deletion, pipes 11.0 0

11.0 i

M407 seal-welded closed l

i M454 UHI deletion, pipes 11.0 0

11.0 j

seal-welded closed 1

M322 INI95A failed Type C 11.0 11.0 0

i j

Test I

M345 IWL806 failed Type C 4300 48.2 4251.8 I

Test M385 1RN405 failed Type C 0

0 0

Test i

M141 Spare penet. (Type B),

0 31.0

-31.0 I

added during outage M234 Spare penet. (Type B),

0 24.2

-24.2 added during outage

+

i i

l E-2 i

. ~..

t i

i As-Found As-Left Leakage Min. Pathway Min. Pathway-Savings Penetration Reason for Testina Leak Rate (SCCM)

Leak Rate (SCCM)

(SCCM)

M452 Spare penet. (Type B),

0 11.0

-11.0 l

added during outage M310 INM425 failed Type C

-22.0 22.0 0

Test i

TOTAL LEAKAGE SAVINGS:

4,309.4 SCCM

.e x'2.1476 X 10

%/ Day SCCM

= 0.00925 %/ Day a

E

.i i

i i

i 6

i l

i i

1 I

E-3 1

l l

l k

e i

i APPENDIX F LOCAL LEAKAGE RATE CONDUCTED SINCE THE LAST ILRT 1

i

?

l 1

)

1 i

4 il

[

j t

2 i

1 f

Since the preoperational Type A Test performed on Catawba Unit 1 in January of 1984, local leak rate testing was conducted in accordance with 10CFR50 Appendix J and the station Technical Specifications.

During this time period, the summation of the Type B and C leakage rates averaged less than 8,000 SCCM, l

which is well below the acceptance criterion of 55,877 SCCM. The maximum Type B and C leakage rate total over this time period was 10,002 SCCM, which still represents less than 0.11 L,.

1 4

Attached are two printouts listing leakage rates for all Type B and C penetrations:

Printout #1 lists the As-Left leakage rates for the Unit 1 EOC-1 refueling outage, and Printout #2 lists the As-Lef t leakage rates for the Unit 1 E0C-2 refueling outage.

The "Reported Leakage" for each penetration is the Maximum Pathway leakage rate. When the measured leakage rate is less than the lower (chreshold) limit for which the Volumetrics Leak Rate Monitor is calibrated, the calibration lower limit is reported as the leakage rate.

Acceptance Criterion 11.2 on Page 11 of the printouts addresses penetrations which are "Bypass Leakage Paths".

(i.e., Any leakage through these penetrations would escape both the Containment Vessel and the Reactor Building, bypassing the Annulus.) Acceptance Criterion 11.3 addresses the Containment Purge System penetrations.

Below is a summary of the Type B and C penetrations which failed the local leak rate test since the last ILRT.

In these instances, although the Maximum Pathway Leakage Rate might have exceeded the acceptance criterion of 0.6 L,

the Minimum Pathway Leakage Rites were always well below the acceptable limits.

The list does not include failures of valves being retested following maintenance, or failures of tht Containment Purge System valves after they had been opened.

(These large butterf)/ valves, which are opened only during plant shutdown, have a 50% probability of leak rate test failure following cycling.

It is for this reason that an As-Found LRT on all of the purge valves was performed prior to opening them.)

VALVE NO. & TYPE LEAKAGE RATE DATE OF FAILURE INV90 (3/4" Reverse Unable to maintain 12/7/84 Check Valve) test pressure 1KC340 (8" Check Valve)

Unable to maintain 4/26/85 test pressure IVLA22 (3/4" Reverse Unable to maintain 8/26/86 Check Valve's test pressure IVQ15B (4" Gate Valve) 2400 SCCM 8/29/86 3

1RN485 (3/4" Reverse 340 SCCM 9/15/86 Check Valve) 4 1NI255B (2" Globe Valve)

Unable to maintain 10/17/86 test pressure F-1 J

~

4 j!-

VALVE NO. 8 TYPE LEAKAGE RATE DATE OF FAILURE t

]

IWL806 (1/2" Reverse 4300 SCCM 10/13/87 j

Check Valve t

INI95A (3/4" Globe Valve)

Unable to maintain 10/16/87-test pressure f

4 i

l-IRN405 (6" Check Valve)

' Unable to maintain 10/20/87 l

test pressure i

i

+

q IVQ3B (4" Gate _ Valve)

Unable to maintain 11/22/87 test _ pressure INM425 (1/2" Reverse Unable to maintain 11/30/87 j

Check Valve) test pressure t

l 5

t i

t f

i t

I I

t i

t J

l 1

i l

I, I

I f

I i

I l

i I

l l

t i

i l

i i

)

i F-2

)

I i

t l

\\

o

Printout #1:

Unit 1 EOC-1 As-Left Leakage Rates Pa9o 1 CATAW8A NUCLEAR STAT 10N CONTROLLING PROCEDURE FOR TYPE 84C LEAK RATE TESTS PT/1/A/4200/0ll ENCLOSURE 13.1 TYPE BSC LEAK RATE TEST REPORT MEAS.

RANGE INSTR.

REPORTED PENET.

VALVE TEST LEAK LOWER ERROR LEAKAGE DATE (SCCM)

LIMIT (SCCM)

(SCCM)

(SCCM) o............................................................u..........

PT/1/A/4200/01C - Containment isolation Valve LRT PT/1/A/4200/418 VQ Valve LRT ( IVQ2A 4 IVQ16A only)

(TYPE C)

  • M212 1NC54A 9/30/86 0.0 20.0 2.0 20.0 INC538 9/30/86 0.0 20.0 2.0
  • M215 IV885 9/29/86 1.0 20.0 2.0 20.0 IV8438 10/29/86 2.4 20.0 2.0
  • M216 INC57 8/20/86 0.9 20.0' 2.0 20.0
  • M219 IVS56 9/29/86 0.0 20.0 2.0 20.0 1VS548 9/29/86 3.0 2.0 1,0 aM220 IVl79 9/16/86 2.4 20.0 2.0 29.7 IVl778 &

10/30/46 29.7 20.0 2.0 1Vl312A

  • M221 1WL868 8/19/86 2.6 20.0 2.0 20.0
  • M240 1RN438 10/15/36 0.0 20.0 2.0 20.0 aM204 IVQ158 9/16/?6 2.1 20.0 2.0 27.0 IVQ16A 10/30/96 27.0 20.0 2.0 sM230 1RN485 9/19/96 0.0 0.0 2.0 20 i
  • M259 1N8262 8/19/86 0.0 20.0 2.0 20.0 l

1N82608 8/19/86 14.0 20.0 2.0

  • M235 1NM78 10/16/86 0.0 20.0 2.0 40.0 1NM3A 10/16/S6 0.0 20.0 2.0 INM6A &

10/16/86 0.0 20.0 2.0 INM424 aM331 1N148 11/02/86 0.1 20.0 2,0 20.0 IN147A 10/26/86 2.8 20.0 2.0 aM310 INM268 10/19/86 4.6 20.0 2.0 78.9 INM22A 10/19/86 58,9 20.0 2.0 INM25A 4 10/19/86 10.0 20.0 2.0 INM425 aM308 1RN430 8/22/86 0.0 20.0 2.0 20.0

Page 2 CATAWBA NUCLEAR STATION CONTAOLLING PROCEDURE FOR TYPE B4C LEAK RATE TESTS PT/1/A/4200/0ll ENCLOSURE 13.1 TYPE BSC LEAK RATE TEST REPORT 4

MEAS.

RANGE INSTR.

REPORTED j

PENET.

VALVE TEST LEAK LOWER ERROR LEAKAGE DATE (SCCM)

LIMIT (SCCM)

(SCCM)

(SCCM)

SQQDOsmanessmasemasessammenessemessemassennagemmassessemassessammaanseem aM316 1RF392 8/28/86 14.1 20.0 2.0 20.0 sM323 1KC430A 8/29/06 198.0 200.0 20.0 200.0 IKC4298 4 8/29/86 23.4 20.0 2.0 1KC47 i

aM322 INI95A 10/29/86 9.4 20.0 2.0 20.0 1NI968 4 10/29/46 1.3 20.0 2.0 IN11205

  • M327 INC141 9/14/86 2.4 20.0 2.0 20.0 1NC142 9/14/46 0.0 20.0 2.0 I

j eM329 INC196A 10/07/86 2.5 20.0 2.0 20.0 j

INC1958 10/07/86 0.4 20.0 2.0 aM332 IVY 16 10/01/86 401.0 200.0 20.0 401.0 IVY 15B 10/01/86 93.5 0.0 2.0 7

  • M337 1YM121 10/21/86 0.0 20.0 2.0 20.0 j

1YMl198 10/21/86 0.0 20.0 2.0 i

r aM348 1WL450A 10/20/86 0.0 20.0 2.0 20.0 1WL4518 10/20/86 0.0 20.0 2.0 l

aM361 1RF448 10/06/86 396.0 200.0 20.0 396.0 i

sM356 IWE20 4 4/18/46 10.5 2.0 1.0 10.5

+

i IWE22 j

aM377 IFW5 8/18/86 586.0 200.0 20.0 586.0 l

j IFW4 8/18/86 2.5 20.0 2.0 i

a eM358 IFW11 8 8/18/86 8.6 20.0 2.0 20.0 j

1FW13 I

eM454 INI266A 4 10/04/86 1.2 2.0 1.0 2.0 j

d IN1267A &

INI2648 &

INI336 i

CM373 1NF229 8/24/06 0.0 2.0 1.0 2,0

{

INF228A 4/24/86 0.0 2.0 1.0 I

sM386 IVQ38 8/24/86 32.8 20.0 2.0 32.8 4

IV02A 11/01/86 0.0 10.0 1.0 i

i

Pago 3 CATAWBA NUCLEAR STATION CONTROLLING PROCEDURE FOR TYPE SSC LEAK RATE TESTS PT/1/A/4200/01L ENCLOSURE 13.1 TYPE BSC LEAK RATE TEST REPORT MEAS.

RANGE INSTR.

REPORTED PENET.

VALVE TEST LEAK LOWER ERROR LEAKAGE

)

DATE (SCCM)

LIMIT (SCCM)

(SCCM) i I

(SCCM)

  • M385 1RN405A 4/22/86 2.5 2.0 1.0 2.5 1

aM372 INF234A 8/24/86 118.0 20.0 2.0 138.0 INF2338 8/24/86 0.0 2.0 1.0 INF235 8/24/86 0.0 2.0 1.0 aM328 1KC340 10/06/86 0.0 20.0 2.0 20.0 M228 INV874 8/15/86 0.0 20.0-2.0 20.0 INV872A 4/15/86 3.3 20.0 2.0 M346 IVY 17A 10/01/86 24.7 20.0 2.0 31.7 IVY 10B 10/01/86 31.7 20.0 2.0 M236 INV90 8/23/86 59.3 20.0 2.0 59.3 i

M347 1NV158 10/25/86 57.0 200.0 20.0 200.0 I

INV14 10/25/86 0.0 20.0 2.0 4

J M345 IWL806 8/26/86 2.7 20.0 2.0 20.0 l

1 M374 IWL321 8/27/86 0.1 20.0 2.0 20.0 1

M359 IWLA22 tot 12/86 2.2 20.0 2.0 20.0 i

M236 1NM728 4/27/86 0.0 20.0 2.0 80.0 INM758 4/27/86 0.5 20.0 2.0 INM785 8/27/86 0.0 20.0 2.0 INMalB 8/27/86 0.5 20.0 2.0 1

INM82A 4 8/27/86 1.6 20.0 2.0 1NM69 M406 1N12558 8 11/06/86 0.0 20.0 2.0 20.0 IN1258A 4

i M321 1MC279 10/04/86 0.6 20.0 2.0 20.0 I

I CNIP-1Mit ANALYZER 8/17/86 2.3 20.0 2.0 20.0 SAMPLE 8/17/86 1.1 20.0 2.0 CNIP-1M12 ANALYZER 8/17/86 3.0 20.0 2.0 20.0

]

SAMPLE 8/17/86 4.0 20.0 2.0 j

CNIF-tMl3 ANALY2ER 8/17/56 0.0 20.0 2.0 20.0 i

SAMPLE

?I17/86 0.0 20.0 2.0

i Pago 4 l

i CATAW8A NUCLEAR STATION CONTROLLING PROCEDURE FOR TYPE 84C LEAK RATE TESTS i

PT/1/A/4200/01L i

]

ENCLOSURE 13.1 i

TYPE SAC LEAK RATE TEST REPORT i

i MEAS.

RANGE INSTR.

REPORTED PENET.

VALVE TEST LEAK LOWER ERROR LEAKAGE j

DATE (SCCM)

LIMIT (SCCM)

(SCCM)

(SCCM)

O Q QO s a s s e s s e s a m e s e s s a a e s s a s s a m a s a m u s e a m m a a m e s s m e n e m a s s e s a m m e m m e st r e s e m e s a d

l CNIP-1Ml4 ANALYZER 8/17/86 31.8 20.0 2.0 32.1 j

SAMPLE 8/17/86 32.1 20.0 2.0 i

CNIP-1 MIS IMIMV6480 8/15/86 0.8 20.0 2.0 20.0 1MIMV6441 8/15/86 0.8 20.0-2.0 i

1 l

CNIP-1MI6 1MIMV6490 8/15/86 0.9 20.0 2.0 20.0 tMIMV6491 8/15/86 0.7 20.0 2.0 CNIP-1Ml7 1MIMV6470 8/15/86 0.7 20.0 2.0 20.0 l

IMIMV6471 8/IS/86 0.8 20.0 2.0 j

CNIP-1 EMF 1MISVS230 9/29/86 0.4 2.0 1.0 3.8 i

(IN)

IMISVS231 9/29/86 3.8 2.0 1.0 CNIP-lEMF 1MISV5232 9/29/86 2.0 2.0 1.0 2.0 (OUT)

IMISVS233 9/29/46 0.2 2.0 1.0 l

CNIP-INS 9 INSPT5060 4 8/18/86 5.1 20.0 2.0 20.0 J

INSPT5170 4 d

INSPT5180 l

4 CNIP-1NS10 INSPT!050 4 8/18/46 2.5 20.0 2.0 20.0 r

1NSPT!250 4 INSPT 260 4

}

I CNIP-INS 11 1NSPTSO40 4 4/18/86 1.9 20.0 2.0 20.0 i

1 INSPT5270 4 1NSPT5380 4 l

INSPTS240 l

i CNIP-INS 12 1NSPT5070 4 8/18/86 12.9 20.0 2.0 20.0 l

INSFT5160 4 l

l INSDT5190 4 INSPT5370 i

Uppor PAL llASVS080 8/16/86 0.0 20.0 2.0 20.0 Air Supply / tlACVS340 4/16/86 10.6 20.0 2.0 t

Equal. Pen. IIACV5360 8/16/86 0.5 20.0 2.0 11ACV5380 8/16/86 0.4 20.0 2.0 Lowor PAL 11ASV5160 8/16/86 0.0 20.0 2.0 20.6 l

Air Supply / 11ACV5350 8/16/86 20.6 20.0 2.0 i

Equal. Pen. 11ACVS370 8/16/86 0.7 20.0 2.0 11ACVS390 8/16/46 0.9 20.0 2.0

Pago S 1

1 CATAWBA NUCLEAR STATION CONTROLLING PROCEDURE FOR TYPE B4C LEAK RATE TESTS PT/1/A/4200/0ll ENCLOSURE 13.1 I

TYPE BSC LEAK RATE TEST REPORT MEAS.

RANGE INSTR.

REPORTED PENET.

VALVE TEST LEAK LOWER ERROR LEAKAGE DATE (SCCM)

LIMIT (SCCM)

(SCCM) i (SCCM) o.......................................................................

PT/1/A/4200/41A - Containment Purge isolation Valve LRT (TYPE C) aM213 1VP17A 4 10/22/86 0.0 20.0' 2.0 20.0 IVPISB aM119 IVPlSA 4 10/22/86 0.0 20.0 2.0 20.0 IVP188 eM140 IVP19A 4 10/22/86 18.0 20.0 2.0 20.0 IVP208 aM357 IVP68 4 10/23/86 3.0 20.0 2.0 20.0 IVP7A i

sM434 IVP85 4 10/22/86 227.0 200.0 20.0 227.0 1VP9A sM364 IVP10A 4 10/22/86 220.0 200.0 20.0 220.0 IVP11B

  • M433 IVP12A 4 10/24/86 6.0 20.0 2.0 20.0 IVP13B aM456 IVPIB 4 10/22/86 56.9 20.0 2.0 56.9 IVP2A sM432 IVP3B 4 10/22/86 640.0 200.0 20.0 640.0 t

IVP4A PT/1/A/4200/01B Electrical Penetration 0-Ring Leak Rate Test (TYPE B)

E101 8/1S/86 0.3 0.0 2.0 2.0 i

E102 8/15/86 0.3 0.0 2.0 2.0 E103 8/15/86 0.5 00 2.0 2.0 i

El04 8115/86 0.0 0.0 2.0 2.0 E105 8/15/86 0.0 0.0 2.0 2.0 j

Pago 6 CATAWBA NUCLEAR STATION CONTROLLING PROCEDURE FOR TYPE SSC LEAK RATE TESTS PT/1/A/4200/01L ENCLOSURE 13.1 TYPE BSC LEAK RATE T,E S T REPORT MEAS.

RANGE INSTA.

REPORTED PENET.

VALVE TEST LEAK LOWER ERROR LEAKAGE DATE (SCCM)

LIMIT (SCCMP (SCCM)

(SCCM) i OOOcasammaammaassaammassammassammaammesmemassamammaammenemmassemenessman E106 8/15/86 0.0 0.0 2.0 2.0 E107 8/15/86 0.1 0,0 2.0 2.0 E108 8/15/86 0.5 0.0 2.0 2.0 E109 8/15/86 0.1 0.0 2.0 2.0 E111 8/15/86 0.2 0.0 2,0 2.0 E112 8/15/86 0.1 0.0 2.0 2.0 E114 8/15/86 0.2 0.0 2.0 2.0 El15 8/15/86 0.0 0.0 2.0 2.0 E116 8/15/86 0,1 0,0 2.0 2.0 E117 4/15/86 0.0 0.0 2.0 2.0 El18 8/15/86 0.2 0.0 2.0 2.0 E120 8/14/86 0.5 0.0 2.0 2.0 E122 8/14/86 0.2 0.0 2,0 2.0 E123 8/14/86 0,5 0,0 2.0 2.0 E124 8/14/86 0.4 0.0 2.0 2.0 I

E126 8/14/86 0.4 0.0 2.0 2,0 E127 8/14/86 0.5 0.0 2.0 2.0 E129 8/15/86 0.4 0.0 2.0 2,0 i

j E130 8/14/86 0.3 0.0 2.0 2.0 E132 8/14/06 0.2 0.0 2.0 2.0 1

E133 8/14/86 0.4 0.0 2.0 2.0 I

E134 8/14/86 0.5 0.0 2.0 2.0 1

i El35 8/14/86 0.3 0,0 2.0 2.0 i

=..

I Pago 7 1

CATAWSA NUCLEAR STATION i

CONTROLLING PROCEDURE FOR TYPE SAC LEAK RATE TESTS PT/l/A/4200/01L ENCLOSURE 13.1 TYPE SAC LEAK RATE TEST REPORT MEAS.

RANGE INSTR.

REPORTED laWNET.

VALVE TEST LEAK LOWER ERROR LEAKAGE DATE (SCCM)

LIMIT (SCCM)

(SCCM) l (SCCM) j o.......................................................................

E136 8/14/86 0.4 0.0 2.0 2.0 E137 8/14/86 0.4 0.0 2.0 2.0 E200 8/14/86 0.1 0.0 2.0 2.0 E202 8/14/86 0.1 0.0 2.0 2.0 E203 8/14/86 0.3 0.0 2.0 2.0 E205 8/14/86 0.3 0.0 2.0 2.0 E206 8/14/86 0.1 0.0 2.0 2.0

)

E208 8/14/86 0 -. 4 0.0 2.0 2.0 i

E211 8/14/86 0.4 0.0 2.0 2.0 E222 8/15/86 0.7 0.0 2.0 2.0 E223 8/16/46 0.0 0.0 2.0 2.0 E224 8/16/86 1.7 0.0 2.0 2.0 E225 8/15/86 1.7 0.0 2.0 2.0 E226 8/15/86 0.9 0.0 2.0 2.0 E231 8/15/86 0.6 0.0 2.0 2.0 E232 4/16/86 0.2 0.0 2.0 2.0 l

E233 8/16/86 0.3 0.0 2.0 2.0 1

E237 8/15/86 0.6 0.0 2.0 2.0 E238 8/16/86 0.5 0.0 2.0 2.0 E244 8/16/86 0.0 0.0 2.0 2.0 E245 8/16/86 1.8 0.0 2.0 2.,

a I

E252 4/16/86 0.0 0.0 2.0 2.0

+

l E268 8/14/86 0.5 0.0 2.0 tA i

i U

l k

Page 4 7

CATAW8A NUCLEAR STATION CONTROLLING PROCEDURE FOR TYPE 84C LEAK RATE TESTS l

PT/1/A/4200/01L ENCLOSURE 13.1 TYPE 84C LEAK RATE TEST REPORT I

MEAS.

RANGE INSTR.

REPORTED PENET.

VALVE TEST LEAK LOWER ERROR LEAKAGE DATE (SCCM)

LIMIT (SCCM)

(SCCM)

(SCCM) cocoo===================================================================

E269 8/14/46 0.5 0,0 2.0 2.0 l

E270 8/14/46 0.2 0.0 2.0 2.0 E271 8/14/86 0.2 0.0 2.0 2.0 E311 8/16/46 0.2 0.0 2.0 2.0 E313 SI14/46 0.4 0.0, 2.0 2.0 E364 4/14/46 0.2 0.0 2.0 2.0 E366 8/14/86 0.4 0.0 2.0 2.0 t

r E379 4/14/86 0.2 0.0 2.0 2.0 E391 8/14/86 0.6 0.0 2.0 2.0 4

E392 8/14/86 0.6 0.0 2.0 2.0

{

E39$

8/14/86 0,6 0.0 2.0 2.0 i

j E39L' 4/14/86 1.0 0.0 2.0 2.0 I

E399 8/14/86 0.9 0.0 2.0 2.0

+

E3102 4/14/86 0.6 0.0 2.0 2.0

[

{

E402 8/15/86 0.3 0.0 2.0 2.0 4

E403 8/15/86 0.0 0.0 2.0 2.0 l

E412 4/14*?6 0.0 0.0 2.0 2.0 E415 4/14/86 0.0 0.0 2.0 2.0

)

E418 8/16/86 0.2 0.0 2.0 2.0

]

j E419 8/16/86 0.6 0.0 2.0 2.0

}

]

E420 8/15/86 0.0 0.0 2.0 2.0 J

j E421 8/15/86 0.0 0.0 2.0 2.0 I

{

E424 8/14/86 0.3 0.0 2.0 2.0 a

1

y H

<. s

't sg V'\\,

Pago 9 f

,7 3

CATAWBA NUCLEAR STATION C1NTROLLING PROCEDURE FOR TYPE BSC LEAK RATE TESTS

\\\\

PT/t/A/4200/01L j'

ENCLOSURE 13.1 TYPE B&C LEAK RATE TEST REPORT 4

8 MEAS.

RANGE INSTR.

REPORTED s

.y PENET.

VALVE TEST LEAK LOWER ERROR LEAKAGE h' (

'h DATE (SCCM)

LIMIT (SCCM)

(SCCM)

\\

(SCCM) wp.......................J.m..,

1/,.' Y E425 8/112/ B'6 0.4 0.0 2.0 2.0 l

E426 8/14/86 0.3 0.0 2.0 2.0 s

't o

/ EE27 8/14/86 0.7 0.0 2.0 2.0 s

/

\\,E +. $ $ s 8/14/86 0.4 0.0 2.0 2.0

'<l

\\

E429 8/14:30 0.7 0.0 2.0 2.0 j

(

E430 8/14/E6 0.4 0.0 2.0 2.0 E43D 8/14/86 0.2 0.0 2.0 2.0 N

/,.[,

E439

,S/14/86 0.4 0.0 2.0 2.0 ks '

g, E440 J/14/86 0.2 0.0 2.0 2.0 s

\\:! E443 8/15/80 0.0 0.0 2.0 2.0 Er 4 8/15/86 0.0 0.0 2.0 2.0 I

E 4 4<w )

i 8/15/86 0.0 0.0 2.0 2.0

, j E44,6 8/15'86 0.0 0.0 2.0 2.0 A

E447 8/i5/86 0.0 0.0 2.0 2.0

'b d

C E44 ?,

8/15/86 0.0 0.0 2.0 2.0

's

'\\

L i

< i E449 8/15/86 0.0 0.0 2.0 2.0 4450 8/15/SG 0.0 0.0 2.0 2.0 L

PT/1/A/4200/d1D Fuel Transfer Tube LRT

'k (TYPE B)

)

^, FUEL TRANSFE.t. TUBE 10/28/86 1.0 0.0 2.0 2.0 A

)\\

PT/1/A/4200/01E - l'p p e r Personnel Air Look LRT l

(TYPE B)

UPPER AL 7/30/8d 1306.0 200.0 20.0 1306.0 3.

ri.

Pogo 10 CATAWBA NUCLEAR STATION CONTROLLING PROCEDURE FOR TYPE BSC LEAK RATE TESTS I

PT/1/A/4200/01L ENCLOSURE 13.1 TYPE 8&C LEAK RATE TEST REPORT MEAS.

RANGE INSTR.

REPORTED PENET.

VALVE TEST LEAK LOWER ERROR LEAKAGE DATE (SCCM)

LIMIT (SCCM)

(SCCM)

(SCCM) e==o....................................................................

PT/1/A/4200/01F Lower Personnel Air Lock LRT (TYPE B)

LOWER PAL 7/22/86 241.0 200.0 20.0 241.0 PT/1/A/4200/01H - Equipment Hatch LRT (TYPE B)

EQUlPMENT HATCM 11/02/86 248.0 200.0 20.0 248.0 PT/1/A/4200/01P NF Penetration LRT (TYPE B)

M371 9/18/86 0.1 2.0 1.0 2.0 M394 9/18/86 0.1 2.0 1.0 2,. 0 M301 Penetration LRT PT/1/A/4200/01R (TYPE B)

M301 10/21/86 2.0 0.0 2.0 2.0 f

PT/1/A/4200/010 Mech. Bellows Structural Integrity LRT i

(TYPE 5)

  • M110 9/25/86 0.0 0.0 2.0 2.0 l

Pago 11 CATAWBA NUCLEAR STATION CONTROLLING PROCEDURE FOR TYPE B4C LEAK RATE TESTS PT/1/A/4200/01L ENCLOSURE 13.1 TYPE BSC LEAK RATE TEST REPORT MEAS.

RANGE INSTR.

REPORTED PENET.

VALVE TEST LEAK LOWER ERROR LEAKAGE DATE (SCCM)

LIMIT (SCCM)

(SCCM)

(SCCM)

ACCEPTANCE CRITERIA VERIFICATION 11.1 Combined leakage rate of less than 0.60 La for all penetrations and valves subject to Type C 4 C leak rate tests when pressurized to Pa (Error Adjusted leakage ( 55,877 secm).

Total Type B 4 C Leakage:

6288.8 seem i

+ Root Sum Squared instr Error:

70.8 scem Error Adjusted Leakage:

6359.6 scem 11.1 Combined Bypass leakage of less than 0.07 La for all penetrations identified in Technical S p e c i f i c a t t e it s Table 3.6-1 when press-urized to Pa (Error Adjusted Leakage ( 6,519 sccm).

Combined Bypass Leakage:

3534.3 seem

+ Root Sum Squared Instr. Error:

54.2 sccm Error Adjusted Leakage:

3588.4 seem aldentifies penetrations listed in Tech. Spec Table 3.6-1.

11.3 Combined leakage rate of less than 0.05 La for all upper / lower and Instrumert room Containment Purge penetrations when pressurized to Pa (Error Adjusted Leakage ( 4,656 secm).

Containment purge Penet. Leakage:

1243.9 scem

+ Root Sum Squared instr. Error:

35.0 seem Error Adjusted Leakage:

1278.9 seem assatzta******* assam **azzas********maartar************rzaam*******mammax iib Data input By:

/

I8'!b Data input Verified By:

/ /f r.,

a

Printout 02:

Unit 1 E0C-2 As-Left Leakage Rates Page 1 CATAWBA NUCLEAR STATION CONTROLLING PROCEDURE FOR TYPE B&C LEAK RATE TESTS PT/1/A/4200/01L ENCLOSURE 13.1 TYPE 8&C LEAK RATE TEST REPORT MEAS.

RANGE INSTR.

REPORTED PENET.

VALVE TEST LEAK LOWER ERROR LEAKAGE DATE (SCCM)

LIMIT

<SCCM)

(SCCM)

<SCCM)

============================================================

PT/1/A/4200/01C Containment isolation Valve LRT PT/1/A/4200/418 VO Valve LRT ( IVQ2A & IVOl6A only)

(TYPE C)

  • M212 INC54A 10/11/87 69.2 20.0 2.0 69.7 1NC538 10/11/87 69.7 20.0 2.0
  • M215 IVB85 11/22/87 2.0 20.0 2.0 20.0 1VB838 11/22/87 0.0 10.0 1.0
  • M216 INCST 10/11/87 0.0 20.0 2.0 20.0
  • M219 IVS56 11/23/87 11.3 20.0 2.0 20.0 IVS548 11/23/87 0.0 10.0 1.0
  • M220 IVIT9 11/27/67 2.0 20.0 2.0 20.0 IVl778 &

11/27/87 3.0 10.0 1.0 IVl312A

  • M221 IWL868 10/7/87 1.2 20.0 2.0 20.0
  • M240 1RN438 11/15/87 7.3 20.0 2.0 20.0
  • M204 IVQ158 11/22/87 0.0 20.0 2.0 132.0 IVOl6A 12/9/87 132.0 20.0 2.0

=M230 1RN485 11/15/87 186.4 20.0 2.0 186.4

  • M259 1N8262 10/11/87 56.4 20.0 2.0 56.4 INB2608 10/11/87 6.5 20.0 2.0
  • M235 1NM78 11/29/87 0.0 20.0 2.0 40.0 INM3A 11/29/87 0.0 20.0 2.0 1NM6A &

11/29/87 0.0 20.0 2.0 i

INM424

  • M331 INI48 10/11/87 77.5 20.0 2.0 77.5 IN147A 10/11/87 5.0 20.0 2.0
  • M310 INM268 11/29/87 0.0 20.0 2.0 121.6 INM22A 10/17/87 10.8 10.0 1.0 INM25A &

12/06/87 110.8 20.0 2.0 INM425

  • M308 1RN430 10/20/87 0.0 10.0 1.0 10.0

Page 8 CATAWBA NUCLEAR STATION CONTROLLING PROCEDURE FOR TYPE 8&C LEAK RATE TESTS PT/1/A/4200/01L ENCLOSURE 13.1 TYPE 8&C LEAK RATE TEST REPORT MEAS.

RANGE INSTR.

REPORT @

PENET.

VALVE TEST LEAK LOWER ERROR LEAKAG@

DATE (SCCM)

LIMIT (SCCM)

<SCCM)

(SCCM)

==========================================================
  • M316 1RF392 10/12/87 22.4 20.0 2.0 22.
  • M323 IKC430A 10/16/87 24.0 20.0 2.0 24.

1KC4298 &

10/16/87 24.1 20.0 2.0 1 't C 4 7

  • M322 1NI95A 11/28/87 10.5 20.0 2.0 20.

1NI968 &

10/16/87 1.0 10.0 1.0 1N11208

  • M327 INC141 10/14/87 0.0

- 20.0 2.0 20.

INC142 10/14/67 2.5 20.0 2.0 mM329 1NC196A 10/14/87 14.5 20.0 2.0 20.

1NC1958 10/14/87 1.1 20.0 2.0

  • M332 IVY 16 10/12/87 192.0 100.0 10.0 192.

IVY 158 10/12/87 32.3 20.0 2.0

  • M337 1YM121 10/12/87 2.0 20.0 2.0 20.

1YM1198 10/12/87 2.0 20.0 2.0

  • M348 IWL450A 10/12/87 0.0 20.0 2.0 20.

1WL4518 10/12/87 0.0 20.0 2.0 mM361 1RF448 10/14/87 32.5 20.0 2.0 32.

  • M356 IWE20 &

10/13/87 4.1 10.0 1.0 10.

1WE22 aM377 1FW5 11/17/87 3.6 20.0 2.0 40.

1FW4 11/17/87 40.2 20.0 2.0

  • M358 1FW11 &

11/17/87 5.9 20.0 2.0 20.

1FW13

  • M373 1NF229 11/;7/87 0.0 10.0 1.0 10.

1NF228A i1/17/87 0.0 10.0 1.0

  • M386 IVQ38 12/01/67 163.0 100.0 10.0 183.

IVQ2A 12/8/87 0.0 10.0 1.0

  • M385 1RN405A 11/15/87 5.8 10.0 1.0 10.

Page 3 CATAWBA NUCLEAR STATION CONTROLLING PROCEDURE FOR TYPE B&C LEAK RATE TESTS PT/1/A/4200/01L ENCLOSURE 13.1 TYPE B&C LEAK RATE TEST REPORT MEAS.

RANGE INSTR.

REPORTED PENET.

VALVE TEST LEAK LOWER ERROR LEAKAGE DATE (SCCM)

LIMIT (SCCM)

<SCCM)

(SCCM) 23E==E=3333==E=333333============33===E=E=3====E=2===========333:3======

  • M372 INF234A 11/16/87 0.0 10.0 1.0 20.0 INF2338 11/16/87 0.0 10.0 1.0 INF235 11/16/87 0.0 10.0 1.0 mM328 1KC340 10/15/87 118.0 20.0 2.0 118.0 M228 INV874 10/14/87 2.6 20.0 2.0 20.0 INV872A 10/14/87 0.8 10.0 1.0 M346 IVY 17A 10/12/87 0.0

, 10.0 1.0 10.0 1.0 10.0 IVY 188 10/12/87 0.3 M256 INV90 10/10/87 2.4 20.0 2.0 20.0 M347 INVISB 11/16/87 0.0 20.0 2.0 20.0 INV14 10/10/87 18.0 20.0 2.0 M345 IWL806 11/27/87 46.2 20.0 2.0 46.2 M374 IWL321 10/13/87 0.0 20.0 2.0 20.0 M359 IWLA22 10/16/87 2.2 20.0 2.0 20.0 M236 INM728 10/13/87 0.0 20.0 2.0 80.0 INM758 10/13/87 2.9 20.0 2.0 1NM788 10/13/87 2.0 20.0 2.0 INM818 10/13/87 3.0 20.0 2.0 INM82A &

10/13/87 0.0 20.0 2.0 INM69 M321 IKC279 10/15/87 2.0 20.0 2.0 20.0 CNIP-1Mll ANALYZER 10/5/87 6.3 20.0 2.0 20.0 S/MPLE 10/5/87 2.8 20.0 2.0 CNIP-1Ml2 ANALYZER 10/5/87 4.5 20.0 2.0 20.0 SAMPLE 10/5/87 6.2 20.0 2.0 CNIP-1Ml3 ANALYZER 10/5/87 2.1 20.0 2.0 20.0 SAMPLE 10/5/87 2.3 20.0 2.0 CNIP-1Ml4 ANALYZGR 10/5/87 32.2 20.0 2.0 32.2 l

SAMPLE 10/5/87 30.6 20.0 2.0 l

CNIP-1 MIS IMIMV6480 10/6/87 0.0 20.0 2.0 20.0 1MIMV6481 10/6/87 0.4 20.0 2.0 l

l

Page (

CATAWBA NUCLEAR STATION CONTROLLING PROCEDURE FOR TYPE B&C LEAK RATE TESTS PT/1/A/4200/01L ENCLOSURE 13.1 TYPE B&C LEAK RATE TEST REPORT MEAS.

RANGE INSTR.

REPORT @

PENET.

VALVE TEST LEAK LOWER ERROR LEAKAGQ DATE (SCCM)

LIMIT (SCCM)

<SCCMq (SCCM)

= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =

CNIP-1MI6 IMIMV6490 10/6/87 4.6 20.0 2.0 20J IMIMV6491 10/6/87 4.7 20.0 2.0 CNIP-1Ml7 1MIMV6470 10/6/87 1.3 20.0 2.0 20.

1MIMV6471 10/6/87 1.5 20.0 2.0 CNIP-1 EMF IMISV5230 10/13/87 0.0 10.0 1.0 10c

<lN) 1MISVS231 10/13/87 1.5 10.0 1.0 CNIP-1 EMF 1MISV5232 10/13/87 1.0

-.10.0 1.0 10<

<OUT)

IMISV5233 10/13/87 3.0 10.0 1.0 CNIP-INS 9 1NSPT5060 &10/5/87 3.8 20.0 2.0 20.

INSPT5170 &

INSP'.'518C CNIP-1NS10 INSPT5050 &10/5/87 1.4 20.0 2.0 20e INSPT5250 &

INSPT5260 CNIP-1NS11 INSPT5040 &10/5/87 4.8 20.0 2.0 20<

INSPT5270 &

INSPT5380 &

INSPT5240 CNIP-INS 12 INSPT5070 410/5/87 7.2 20.0 2.0 20<

INSPT5160 &

INSPT5190 &

INSPT5370 Upper PAL 11ASV5080 10/6/87 2.8 20.0 2.0 45.

Air Supply / 11ACV5340 10/6/87 45.0 20.0 2.0 Equal. Pen. IIACV5360 10/6/87 0.9 20.0 2.0 IIACV5380 10/6/87 6.8 20.0 2.0 Lower PAL 11ASVS160 10/8/87 0.0 2.0 1.0 3.

Air Supply / IIACV5350 10/8/87 3.1 2.0 1.0 Equal. Pen. IIACV5370 10/8/87 0.2 2.0 1.0 IIACV5390 10/8/87 0.2 2.0 1.0 l

l Page 5 CATAWBA NUCLEAR STATION CONTROLLING PROCEDURE FOR TYPE B&C LEAK RATE TESTS PT/1/A/4200/01L ENCLOSURE 13.1 TYPE 8&C LEAK RATE TEST REPORT MEAS.

RANGE INSTR.

REPORTED PENET.

VALVE TEST LEAK LOWER ERROR LEAKAGE DATE (SCCM)

LIMIT (SCCM)

(SCCM)

(SCCM)

============================================================

PT/1/A/4200/41A Containment Purge isolation Valve LRT.

(TYPE C)

  • M213 IVP17A &

12/18/87 0.0 10.0 1.0 10.0 IVP188

  • M119 1VP15A &

12/18/87 763.0 200.0 20.0 763.0 IVP168

  • M140 1VP19A &

12/18/87 241.0

~200.0 20.0 241.0 IVP208

  • M357 IVP68 &

12/18/87 464.0 200.0 20.0 464.0 IVPTA

  • M434 IVP88 &

12/18/87 687.0 100.0 10.0 687.0 IVP9A

  • M368 IVP10A &

12/18/87 382.0 200.0 20.0 382.0 1VP118

  • M433 IVP12A &

12/18/87 702.0 100.0 10.0 702.0 IVP138

  • M456 IVP1B &

12/18/87 115.0 100.0 10.0 115.0 IVP2A

  • M432 IVP3B &

12/18/87 710.0 100.0 10.0 710.0 IVP4A PT/1/A/4200/018 Electrical Penetration 0-Ring Leak Rate Test (TYPE B)

E101 10/6/87 0.0 20.0 2.0 20.0 E102 10/6/87 0.0 20.0 2.0 20.0 E103 10/6/87 0.0 20.0 2.0 20.0 E104 10/6/87 0.0 20.0 2.0 20.0 E105 10/6/87 0.0 20.0 2.0 20.0 E106 10/6/87 0.0 20.0 2.0 20.0

Page G

. CATAWBA NUCLEAR STATION CONTROLLING PROCEDURE FOR TYPE B&C LEAK RATE TESTS PT/1/A/4200/01L ENCLOSURE 13.1 TYPE B&C LEAK RATE TEST REPORT MEAS.

RANGE INSTR.

REPORT PENET.

VALVE TEST LEAK LOWER ERROR LEAKAG OATE (SCCM)

LIMIT (SCCM)

(SCCM (SCCM) 333333333333333333333333333333333333333333333333333333333333333333333C E107 10/6/87 0.0 20.0 2.0 20.

E108 10/6/87 0.0 20.0 2.0 20.

E109 10/6/87 0.0 20.0 2.0 20.

E111 10/6/87 0.0 20.0 2.0 20c E112 10/6/87 0.0 20.0 2.0 20.

E114 10/6/87 0.0 20.0 2.0 20.

E115 10/6/87 0.0 20.0 2.0 20.

E116 10/6/87 0.0 20.0 2.0 20.

E117 10/6/87 0.0 20.0 2.0 20.

E118 10/6/87 0.0 20.0 2.0 20.

.E1*0 10/6/87 0.0 20.0 2.0 20.

C;22 10/6/87 0.0 20.0 2.0 20.

E123 10/6/87 0.0 20.0 2.0 20 E124 10/6/87 0.0 20.0 2.0 2 0 E126 10/6/87 0.0 20.0 2.0 20.

1 E127 10/6/87 0.0 20.0 2.0 20.

E129 10/6/87 0.0 20.0 2.0 20.

E130 10/6/87 0.0 20.0 2.0 20.

E132 10/6/87 0.0 20.0 2.0 20.

E133 10/6/87 0.0 20.0 2.0 20.

E134 10/6/87 0.0 20.0 2.0 20 3

E135 10/6/87 0.0 20.0 2.0 20.

E136 10/6/87 0.0 20.0 2.0 20.

Page 7 CATAWBA NUCLEAR STATION CONTROLLING PROCEDURE FOR TYPE B&C LEAK RATE TESTS PT/1/A/4200/01L ENCLOSURE 13.1

{

TYPE B&C LEAK RATE TEST REPORT MEAS.

RANGE INSTR.

REPORTED PENET.

VALVE TEST LEAK LOWER ERROR LEAKAGE DATE (SCCM>

LIMIT (SCCM)

<SCCM)

(SCCM)

============================================================

E137 10/6/87 0.0 20.0 2.0 20.0 E200 10/6/87 0.0 20.0 2.0 20.0 E202 10/6/87 0.0 20.0 2.0 20.0 E203 10/6/87 0.0 20.0 2.0 20.0 E205 10/6/87 0.0 20.0 2.0 20.0 E206 10/6/87 0.0 20.0 2.0 20.0 E208 10/6/87 0.0 20.0 2.0 20.0 J

E211 10/6/87 0.0 20.0 2.0 20.0 E222 10/6/87 0.0 20.0 2.0 20.0 E223 10/11/87 0.0 20.0 2.0 20.0 E224 10/6/87 0.0 20.0 2.0 20.0 E225 10/6/87 0.0 20.0 2.0 20.0 E226 10/6/87 0.0 20.0 2.0 20.0 E231 10/6/87 0.0 20.0 2.0 20.0 E232 10/6/87 0.0 20.0 2.0 20.0 E233 10/6/87 0.0 20.0 2.0 20.0 E237 10/6/87 0.0 20.0 2.0 20.0 E238 10/6/87 0.0 20.0 2.0 20.0 E244 10/6/87 0.0 20.0 2.0 20.0 E245 10/6/87 0.0 20.0 2.0 20.0 E252 10/6/87 0.0 20.0 2.0 20.0 E268 10/6/87 0.0 20.0 2.0 20.0 E269 10/6/87 0.0 20.0 2.0 20.0

Paeo @

CATAW8A NUCLEAR STATION CONTROLLING PROCEDURE FOR TYPE B&C LEAK RATE TESTS PT/1/A/4200/01L ENCLOSURE 13.1 TYPE B&C LEAK RATE TEST REPORT MEAS.

RANGE INSTR.

REPORT @

PENET.

VALVE TEST LEAK LOWER ERROR LEAKAG@

DATE (SCCM)

LIMIT (SCCM)

(SCCM)

<SCCM>

=============================r============================

E270 10/6/87 0.0 20.0 2.0 20.

E271 10/6/87 0.0 20.0 2.0 20.

E311 10/6/87 0.0 20.0 2.0 20.

E313 10/5/87 0.0 20.0 2.0 20.

E364 10/5/87 0.0 20.0 2.0 20.

E366 10/5/87 0.0 20.0 2.0 20.

E379 10/5/87 0.0 20.0 2.0 20.

E391 10/5/87 0.0 20.0 2.0 20.

E392 10/5/87 0.0 20.0 2.0 20.

E395 10/5/87 0.0 20.0 2.0 20.

E398 10/5/87 0.0 20.0 2.0 20.

E399 10/5/87 0.0 20.0 2.0 20.

E3102 10/5/87 0.0 20.0 2.0 20.

E402 10/6/87 0.0 20.0 2.0 20.

E403 10/6/87 0.0 20.0 2.0 20.

E412 10/5/87 0.0 20.0 2.0 20.

E415 10/5/87 0.0 20.0 2.0 20.

E418 10/6/87 0.0 20.0 2.0 20.

E419 10/6/87 0.0 20.0 2.0 20.

E420 10/6/87 0.0 20.0 2.0 20.

E421 10/6/87 0.0 20.0 2.0 20.

E424 10/5/87 0.0 20.0 2.0 20.

E425 10/5/87 0.0 20.0 2.0 20.

i Page 9 CATAWBA NUCLEAR STATION CONTROLLING PROCEDURE FOR TYPE B&C LEAK RATE TESTS PT/1/A/4200/01L ENCLOSURE 13.1 TYPE 8&C LEAK RATE TEST REPORT MEAS.

RANGE INSTR.

REPORTED PENET.

VALVE TEST LEAK LOWER ERROR LEAKAGE DATE

<SCCM)

LIMIT

<SCCM)

(SCCM)

(SCCM)

============================================================

E426 10/5/87 0.0 20.0 2.0 20.0 Et27 10/5/87 0.0 20.0 2.0 20.0 E428 10/5/87 0.0 20.0 2.0 20.0 E429 10/5/87 0.0 20.0 2.0 20.0 E430 10/5/87 0.0 20.0 2.0 20.0 E431 10/5/87 0.0 20.0 2.0 20.0 E439 10/5/87 0.0 20.0 2.0 20.0 E440 10/5/87 0.0 20.0 2.0 20.0 E443 10/6/87 0.0 20.0 2.0 20.0 E444 10/6/87 0.0 20.0 2.0 20.0 E445 10/6/87 0.0 20.0 2.0 20.0 E446 10/6/87 0.0 20.0 2.0 20.0 E447 10/6/87 0.0 20.0 2.0 20.0 E448 10/6/87 0.0 20.0 2.0 20.0 E449 10/6/87 0.0 20.0 2.0 20.0 E450 10/6/87 0.0 20.0 2.0 20.0 PT/1/A/4200/010 - Fuel Transfer Tube LRT i

(TYPE 8)

FUEL TRANSFER TUBE 11/20/87 0.0 10.0 1.0 10.0 PT/1/A/4200/01E Upper Personnel Air Lock LRT (TYPE 8)

UPPER PAL 09/21/87 974.0 220.0 21.0 974.0

Page l'

CATAWBA NUCLEAR STATION CONTROLLING PROCEDURE FOR TYPE B&C LEAK RATE TESTS PT/1/A/4200/01L ENCLOSURE 13.1 TYPE B&C LEAK RATE TEST REPORT MEAS.

RANGE INSTR.

REPORTE!

PENET.

VALVE TEST LEAK LOWER ERROR LEAKAGEI DATE (SCCM)

LIMIT (SCCM)

(SCCM>'

(SCCM)

=== ::::::

==========================================================3)

PT/1/A/4200/01F Lower Personnel Air Lock LRT (TYPE B)

LOWER PAL 09/25/87 696.8 20.0 22.0 696.l PT/1/A/4200/01H Equipment Hatch LRT (TYPE B)

EOUlPMENT HATCH 12/20/87 55.0 10.0 1.0 5 5. l PT/1/A/4200/01P NF Penetration LRT (TYPE 8)

M371 11/21/87 8.7 10.0 1.0 10.

M394 11/20/87 8.0 20.0 2.0 20.

PT/1/A/4200/01R - M301, M141, M234, M452 Penetrations LRT (TYPE B)

M301 11/19/87 0.0 10.0 1.0 10.

M141 10/22/87 29.0 20.0 2.0 29.

M234 11/19/87 23.2 10.0 1.0 23.

M452 12/18/87 26.8 10.0 1.0 26.

PT/1/A/4200/01G - Mech. Bellows Structural integrity LRT (TYPE 8)

  • M110 12/03/87 0.0 20.0 2.0 20.

PT/1/A/4200/01M Incore Instr Thermocouple Penet LRT (TYPE B)

E121 6/10/87 3.0 10.0 1.0 10.

E138 6/10/87 0.0 10.0 1.0 10.

Page 11 CATAWBA NUCLEAR STATION CONTROLLING PROCEDURE FOR TYPE B&C LEAK RATE TESTS PT/1/A/4200/0ll ENCLOSURE 13.1 TYPE B&C LEAK RATE TEST REPORT MEAS.

RANGE INSTR.

REPORTED PENET.

VALVE TEST LEAK LOWER ERROR LEAKAGE DATE (SCCM>

LIMIT (SCCM)

(SCCM>'

(SCCM)

============_===============================================

l l

l ACCEPTANCE CRITERIA VERIFICATION 11 1 Combined leakage rate of less than 0.60 La for all penetrations and valves subject to Type 8 & C leak rate, tests when pressurized to Pa (Error Adju3ted leakage < 55,877 scem).

Total Type B & C Leakage:

9941.1 seem

+ Root Sum Squared instr. Error:

00.9 seem Error Adjusted Leakage:

10002.0 seem 11.2 Combined Bypass leakage of less than 0.07 La for all penetrations identified in Technical Specifications Table 3.6-1 when press-ur# zed to Pa (Error Adjusted Leakage < 6,519 secm).

Combined Bypass Leakage:

5689.8 seem Root Sum Squared Instr. Error:

48.1 scem

+

Erfor Adjusted Leakage:

5737.9 seem 2ldentifies penetrations listed in Tech. Spec Table 3.6-1 11.3 Combined leakage rate of less than 0.05 La for all upper / lower and instrument room Containment Purge penetrations when pressurized to Pa (Error Adjusted Leakage < 4,656 secm).

Containment Purg, Penet Leakage:

4074.0 seem

+ Root Sum Squared instr Error:

44.7 seem Error Adjusted Leakage 4118.7 sccm s a n s s x.s x s m a n s x x n n n n s n z s s s s s s s x a s s n a s s n n n s s s s s m a n a s s a n x a s u n s a x x s x x x x x x.s x x

=

Ou M.

/ 4 -Al-f) caia ingut ey, Dala inpu! Verii

,2 By:_

/ M' 7/d7

/

e APPENDIX G TEST DATA I

I l

(

t i

Test Data Printouts l

Mass Point Leak Rate Analysis (4 pages)

Calculated Values By Reading (28 pages) i Instrument Calibrated Data (64 pages)

Calibration Data By Point (3 pages)

Significant Reading #s i

Temperature Stabilization:

Readings #36 to 52 Pressure Decay Test: Readings'#52 to 148 Verification Test:

Readings #204 to 226 e

i NOTE: Dewpoint Temperature Sensors 57, 58, and 61 were installed as backups only and were not used in the leakage ~ rate calculations.

G-1 j

i s

MASS POINT LEAK RATE ANALYSIS PAGE 1

RDG TIME NORM. MASS MEASURED LEAK UCL LEAK (MINUTES)

(WT %/ DAY)

(WT %/ DAY) 52

.00 1.000000 53 14.98 1.000025

.244136 54 29.98 1.000117

.561861 1.006711 55 44.98 1.000001

.091892

.741501 56 59.98 1.000090

.149988

.243170 57 74.98 1.000035

.069694

.183407 58 89.97 1.000038

.036996

.136404 59 104.97

.999973

.032139

.178941 60 119.97

.999944

.081073

.204184 61 134.97

.939979

.082918

.179329 62 149.97 1.000034

.056348

.138885 63 164.97 1.000093

.016845

.096338 64 179.95

.999948

.038265

.108442 65 194.95

.999873

.071284

.139925 66 209.95 1.000025

.054464

.115983 67 224.95

.999913

.065704

.120415 68 240.40 1.000014

.053195

.102821 69 255.40

.999913

.060,457

.104956 70 270.40

.999912

.064900

.104796 71 285.40

.999880

.071568

.107959 72 300.42

.999979

.063261

.097109 73 316.23

.999937

.060934

.091684 74 331.23

.999864

.066206

.094679 75 346.23

.999908

.065360

.091404 76 361.23

.999979

.057762

.082816 77 376.25

.999943

.354242

.077581 78 391.25

.999906

.053890

.075463 79 406.25

.999801

.060590

.081649 80 421.25

.999812

.064884

.084910 81 436.25

.999822

.067295

.086110 82 451.25

.999893

.064767

.082521 83 466.27

.999873

.063413

.080092 84 481.27

.999815

.064921

.080642 85 496.28

.999857

.063826

.078647 86 511.28

.999863

.062318

.076357 87 526.28

.999865

.060700

.074042 88 541.28

.999819

.060953

.073566 89 556.30

.999778

.062497

.074532 90 571.30

.999777

.063619

.075082 91 586.30

.999847

.061906

.072917

MASS P C3 I N T LEAK RATE ANALYSIE PAGE 8

RDG T DEE NORM. MASS PF.ASURED LEAM UCL LEAM (MIP4.JTES)

(WT W/ DAY)

(WT %/ DAY) 92 601.30

.999758

.063173

.073713 93 616.32

.999805

.062572

.072621 94 631.32

.999787

.062391

.071969 95 646.32

.999657

.065805

.075528 96 661.32

.999756

.065872

.075158 97 676.33

.999695

.067369

.076366 98 691.33

.999811

.065533

.074325 99

-706.35

.999757

.065084

.073518 100 721.35

.999710

.065623

.073726 101 736.35

.999959

.060351

.069657 102 751.37

.999966

.055388

.065537 103 766.37

.999958

.051022

.061655 l

104 781.37

.999693

.052337

.062644 105 796.38

.999803

.051280

.061255 106 811.40

.999652

.053048

.062808 107 826.40

.999463

.057926

.068451 108 841.42

.999635

.059213

.069442 109 856.43

.999647

.060071

.069980 110 871.48

.999731

.059385

.068978 111 886.50

.999914

.055794

.065692 112 901.50

.999878

.053004

.062947 113 916.52

.999767

.052027

.061693 114 931.53

.999762

.051135

.060532 115 946.53

.999773

.050096

.059252 116 961.55

.999870

.047783

.056932 117 976.57

.999765

.046971

.055875 118 991.58

.999579

.048510

.057273 119 1006.60

.999665

.048802

.057311 120 1021.60

.999561

.050244

.058620 121 1036.63

.999591

.051162

.059345 122 1051.65

.999765

.049994

.058024 123 1066.67

.999552

.051190

.059081 124 1081.67

.999734

.050297

.058018 125 1096.68

.999722

.049542

.057088 126 1111.70

.999647

.049549

.056893 127 1126.72

.999742

.048577

.055787 128 1141.73

.999838

.046713

.053960 119 1156.75

.999663

.046567

.053623 130 1174.77

.999599

.046971

.053063 131 1186.76

.999617

.047148

.053870

MASS POINT L_ E A K RATE ANAL.YSIS PAGE 3

RDG TIME NORM. MASS MEASURED LEAK UCL LEAK (MINUTES)

(WT %/ DAY)

(WT %/ DAY) 132 120'.80

.999442

.048785

.055526 133 1216.82

.999579

.049098

.05568:

134 1231.83

.999534

.443720

.056171 135 1246.85

.999678

.249098

.055423 136 1261.85

.999550

.049487

.055673 137 1276.87

.333575

.049616

.055659 138 1291.86

.999674

.348354

.054892 133 1306.90

.999556

.049151

.054356 l

140 1321.90

.999645

.048674.

.054366 l

141 1336.92

.99966A

.048027

.053627 142 1351.95

.999817

.046366

.052070 143 1366.95

.999682

.045665.

.051302 144 1381.98

.999601

.045554

.051051

~

145 1397.00

.999645

.045117

.050512 146 1412.02

.99964e

.244656

.049956 147 1427.02

.399515

.045014

.050215 148 1442.03

.999458

.043669

.050801

(

149 1457.05

.999535

.045738

.050827 150 1472.07

.995537

.045883

.052810 151 1487.08

.999476

.046280

.051123 152 1502.10

.999547

.046231

.050977 153 1517.13

.999573

.046014

.050672 154 1532.15

.999478

.e46298

.050873 155 1547.18

.999448

.346696

.051193 156 1562.18

.999477

.046897

.051318 157 1577.20

.999458

.047160

.051505 l

158 1592.22

.999488

.047233

.051496 153 1607.23

.939383

.047783

.052007 160 1622.25

.999491

.047774

.051914 161 1637.27

.999485

.047767

.051831 162 1652.30

.999484

.047740

.051721 163 1667.32

.999446

.047864

.051786 164 1682.33

.999400

.048165

.052028 165 1697.35

.999439

.048258

.052054 166 1712.37

.999351

.048706

.052460 167 1727.38

.999383

.048972

.052670 168 1742.40

.999465

.048864

.052500 169 1757.45

.339391

.049040

.052618 870 1772.47

.999437

.049002

.052520 171 1787.48

.999450

.048895

.052356

Mass POINT LEAK RATE ANALYSIB PAGE RDG T!!E NORM. MASS MEASURED LEAK UCL LEAK (MINUTES)

(WT %/ DAY)

(WT %/ DAY) 172 1802.50

.999369

.049090

.052498 173 1817.52

.999430

.449023

.052376 174 1832.55

.999260

.049578

.052919 175 1847.57

.999289

.049982

.053291 176 1862.60

.999248

.050497

.053790 177 1877.62

.999249

.050967

.054239 178 1892.65

.999192

.051598

.054874 179 1907.67

.999326

.051714

.054941 180 1922.68

.999370

.051656

.054832 181 1937.70

.999319

.051753

.054882 182 1952.73

.999422

.051485

.054577 183 1967.77

.999404

.051271,

.054322 184 1982.78

.999246

.051559

.054578 185 1997.80

.999276

.051721

.054698 186 2012.83

.999488

.051194

.054170 187 2027.85

.999468

.050736

.053700 188 2042.87

.999209

.051069

.054007 189 2057.88

.999151

.051546

.054477 190 2072.92

.999322

.051481

.054371 191 2087.93

.999203

.051751

.054611 192 2102.97

.999212

.051969

.054795 193 2117.98

.999303

.051905

.054692 194 2133.00

.999194

.052132

.054889 195 2148.02

.999183

.052364

.055091 196 2163.03

.999180

.052581

.055279 197 2178.05

.999181

.052771

.055438 198 2193.08

.999279

.052679

.055311 199 2208.12

.999158

.052893

.055497 200 2223.13

.999093

.053251

.055842 201 2238.17

.999071

.053635

.056219 202 2254.77

.999175

.053730

.056280 203 2269.80

.999209

.053724

.056241 204 2284.83

.999099

.053973

.056468

-w

1 2

CALCULATED VALUES BY READING PAGE 1

RDG TIME MASS TEMP VAP PRESS 1

8:35:30 LOWER CONTAINMENT 23606.47 76.753

.3383 15.1060 UPPER CONTAINMENT 52477.68 70.710

.3113 15.0970 ICE CONDENSER 13619.58 10.599

.0356 15.1000 TOTAL 89703.73 2

8:50:29 LOWER CONTAINMENT 23619.68 76.735

.3375 15.1130 UPPER CONTAINMENT 52508.56 70.641

.3105 15.1030 ICE CONDENSER 13627.55 10.548

.0354 15.1070 TOTAL 85755.79 3

9: 5:28 LOWER CONTAINMENT 23850.94 7G.936

.3453 15.2710 UPPER CONTAINMENT 53014.V8 71.107

.3138 15.2620 ICE CONDENSER 13753.75 11.131

.0360 15.2660 TOTAL 90619.47 4

9:20:28 LOWER CONTAINMENT 24285.12 77.055

.3466 15.5460 UPPER CONTAINMENT 53914.31 71.602

.3200 15.5360 ICE CONDENSER 13998.22 11.267

.0358 15.5410 TOTAL 92197.65 5

9:35:28 LOWER CONTAINMENT 24704.59 77.185

.3469 15.8140 UPPER CONTAINPENT 54824.02 71.909

.3243 15.8060 ICE CONDENSER 14238.75 11.317

.0357 15.8090 TOTAL 93767.36 f

6 9:50:27 LOWER CONTAINMENT 25216.27 77.335

.3481 16.1400 UPPER CONTAINMENT 55948.08 72.046

.3278 16.1310 ICE CONDENSER 14536.69 11.185

.0361 16.1350 TOTAL 95701.04 7

10: 5:27 LOWER CONTAINMENT 25965.36 77.568

.3480 16.6160 LPPER CONTAINMENT 57544.85 72.671

.3326 16,6060 ICE CONDENSER 14959.98 11.366

.0360 16.6100 TOTAL 98470.20 l

8 10:20:26 LOWER CONTAINMENT 26707.78 77.663

.3479 17.0840 UPPER CONTAINMENT 59150.49 72.995

.3354 17.0730 l

ICE CONDENSER 15380.96 11.404

.0362 17.0780 i

TOTAL 101239.23 9

10:35:25 LOWER CONTAINMENT 27431.95 77.805

.3495 17.5440 UPPER CONTAINMENT 60747.91 73.183

.3373 17.5330 l

ICE CONDENSER 15793.79 11.467

.0365 17.5380 TOTAL 103973.65 10 10:50:25 LOWER CONTAINMENT 28147.80 77.917

.3491 17.9960 i

UPPER CONTAINMENT 62327.86 73.306

.3380 17.9850 ICE CONDENSER 16200.86 11.458

.0367 17.9890 TOTAL 106676.52

C A L C U L A *T EE D VALUES BY REE AD I NG PAGE RDG TIME MASS TEMP VAP PRESS 11 11: 5:24 LOWER CONTAIPOENT 28868.97 77.988

.2516 18.4530 UPPER CONTAINMENT 63932.79 73.366

.3396 18.4430 ICE CONDENSER 16614.65 11.448

.0366 18.4470 TOTAL 109416.41 12 11:20:23 LOWER CONTAINMENT 29D91.61 78.104

.3525 18.9110 UPPER CONTAINMENT 65515.91 73.527

.3397 18.8970 ICE CONDENSER 17024.94 11.505

.0367 18.9040 TOTAL 112132.46 13 11:35:23 LOWER CONTAIPOIENT 30324.80 78.108

.3535 19.3720 UPPER CONTAINMENT 67129.11 73.641

.3407 19.3590

)

ICE CONDENSER 17443.67 11.397

.0371 19.3640 TOTAL 114897.58 14 11:50:22 LOWER CONTAIP# TENT 31063.64 78."165

.3521 9.8360 LMER CONTAINPENT 68761.51 73.739

.3406 19.8250 ICE CONDENSER 17858.47 11.503

.0370 19.8280 TOTAL 117683.62

&5 12 5:22 LOWER CONTAIPetENT 31795.69 78.310

.3546 20.3030 LPPER CONTAINMENT 70365.69 73.935

.3417 20.2880 ICE CONDENSER 18274.03 11.608

.0370 20.2930 TOTAL 120435.41 16 12:20:22 LOWER CONTAINMENT 32537.83 78.364

.3539 20.7700 UPPER CONTAINMENT 72003.17 74.038

.3416 20.7560 ICE CONDENSER 18692.72 11.693

.0372 20,7610 TOTAL 123233.71 17 12:35:21 LOWER CONTAINMENT 33282.67 78.395

.3553 21.2400 UPPER CONTAINMENT 73637.77 74.156

.3416 21.2240 ICE CONDENSER 19112.66 11.749

.0370 21.2290 TOTAL 126033.10 18 12350:21 LOWER CONTAINMENT 34012.40 78.501

.3552 21.7020 LPPER CONTAINMENT 75259.45 74.241

.3423 21.6880 ICE CONDENSER 19529.61 11,786

.0370 21.6930 TOTAL 128801.47 19 13: 5:21 LOWER CON 1AINMENT 34750.23 78.523

.3553 22.1660 UPPER CONTAINMENT 76897.27 74.214

.3428 22.1520 ICE CONDENSER 19944.86 11.880

.0372 22.1580 TOTAL 131592.36 20 13:20:21 LOWER CONTAINMENT 35481.15 78.563

.3539 22.6250 LPPER CONTAINMENT 78513.88 74.259

.3405 22.6100 ICE CONDENSER 20354.02 11.306

.0372 22.6130 TOTAL 134349.06 4

CALCULATED VALUES BY READING PAGE 3

s RDG TIME MASS TEMP VAP PRESS 21 13:35:20 LOWER CONTAINMENT 36219.92 78.626

.3535 23.0910 UPPER CONTAINMENT 80119.95 74.400

.3409 23.0720 ICE CONDENSER 20770.71 11.957

.0375 23.0780 TOTAL 137110.58 22 13:50:20 LDWER CONTAINMENT 36939.84 78.664

.3459 23.5370 UPPER CONTAINMENT 816o).37 74.318

.3443 23.5200 ICE CONDENSER 21171.80 12.001

.0373 23.5250 TOTAL 139811.21 23 14: 5:20 LOWER CONTAINMENT 37G80.97 78.578

.3354 23.9880 UPPER CONTAINMENT 83322.57 74.167

.3426 23.9720 l

ICE CONDENSER 21575.72 12.077

.0374 23.9770 TOTAL 142579.26 24 14:20:20 LOWER CONTAINMENT 38415.09 78.6i6

.3269 24.4420 UPPER CONTAINMENT 84921.98 74.126

.3439 24.4250 ICE CONDENSER 21980.29 12.158

.0373 24.4300 TOTAL 145317.35 25 14:35:20 LOWER CONTAINMENT 39097.98 78.694

.3256 24.8730 LAPER CONTAINMENT 86445.36 74.113

.3425 24.8550 ICE CONDENSER 22361.11 12.311

.0376 24.8610 TOTAL 147904.45 26 14:50:20 LOWER CDNTAINMENT 39825.67 78.713

.3229 25.3280 UPPER CONTAINMENT 88060.64 74.109

.3407 25.3110 ICE CONDENSER 22770.50 12.357

.0377 25.3180 TOTAL 150656.81 1

27 15: 5:19 LOWER CONTAINMENT 40548.26 78.714

.3202 25.7790 l

UPPER CONTAINMENT 89651.53 74.096

.3402 25.7610 l

ICE CONDENSER 23168.59 12.521

.0378 25.7690 l

)

TOTAL 153368.38 l

i 28 15:20:19 LOWER CDNTAINMENT 41274.73 78.688

.3173 26.2310 LFPER CONTAINMENT 91259.15 74.076

.3383 26.2140 l

ICE CONDENSER 23569.73 12.638

.0378 26.2210 TOTAL 156103.61 29 15:35:19 LDWER CONTAINMENT 41988.45 78.759

.3147 26.6800 UPPER CONTAINMENT 92822.20 74.169

.3385 26.6620 ICE CONDENSER 23970.31 12.688

.0380 26.6690 TOTAL 158780.97 30 15:50:19 LOWER CDNTAINMENT 42712.07 78.724

.3131 27.1310 1

UPPER CONTAINMENT 94429.56 74.157

.3353 27.1140 ICE CONDENSER 24380.06 12.645

.0382 27.1220 TOTAL 161521.70 l

CALCULATED VALUES BY READING PAGE RDG TIME MASS TEMP VAP PRESS 31 16: 5:19 LOWER CONTAINMENT 43429.90 78.708

.3092 27.5770 UPPER CONTAINMENT 96025.02 74.128

.3333 27.5630 ICE CONDENSER 24782.10 12.668

.0383 27.5700 TOTAL 164237.02 32 16:20:19 LOWER CONTAINMENT 44144.59 78.748

.3074 28.0260 UPPER CONTAINMENT 97599.23 74.161

.3322 28.0100 ICE CONDENSER 25178.57 12.777

.0383 28.0170 TOTAL 166922.39 33 16:35:19 LOWER CDNTAINMENT 44875.02 78.673

.3047 28.4780 UPPER CONTAINMENT 99208.02 74.148

.3287 28.4620 ICE CONDENSER 25584.97 12.761

.0387 28.4680 TOTAL 169668.01

~

34 16:50:19 LOWER CONTAINMENT 45604.17 78.2'80

.3098 28.9200 UPPER CONTAINMENT 100760.72 74.159

.3278 28.9020 ICE CONDENSER 25979.43 12.819

.0389 28.9100 TOTAL 172344.32 35 17: 5:19 LOWER CONTAINMENT 46332.80 77.921

.3131 29.3610 UPPER CONTAINMENT 102334.96 74.116

.3267 29.3450 ICE CONDENSER 26374.69 12.873

.0393 29.3530 TOTAL 175042.45 36 17:20:19 LOWER CONTAINMENT 46762.50 77.<,~3

.3131 29.6060 UPPER CONTAINMENT 103265.46 73.783

.3241 29.5880 ICE CONDENSER 26598.89 12.747

.0390 29.5940 TOTAL 176626.85 37 17:35:19 LOWER CONTAINMENT 46719.76 77.189

.3184 29.5690 LPPER CONTAINMENT 103303.73 73.066

.3176 29.5530 ICE CONDENSER 26568.58 12.719

.0394 29.5590 TOTAL 176592.06

)

38 17:50:19 LOWER CONTAINMENT 46710.32 76.944

.3166 29.5480 UPPER CONTAINMENT 103336.25 72.603

.3108 29.5300 ICE CONDENSER 26550.17 12.715

.0391 29.5380 TOTAL 176596.74 39 18: 5:19 LOWER CONTAINMENT 46720.86 76.785

.3097 29.5390 UPPER CONTAINMENT 103380.10 72.341

.3048 29.5220 ICE CONDENSER 26541.77 12.698

.0395 29.5280 TOTAL 176642.73 40 18:20:18 LOWER CONTAINMENT 46701.97 76.763

.3107 29.5270 UPPER CONTAINMENT 103368.57 72.274

.3008 29.5110 ICE CONDENSER 26524.01 12.854

.0395 29.5180 TOTAL 176594.54

2 CALCULATED VALUES BY READING PAGE 5

RDG TIME MASS TEMP VAP PRESS 41 18335:18 LOWER CONTAIPOENT 46704.92 76.600

.3077 29.5170 LPPER CONTAINMENT 103392.69 72.049

.2963 29.5010 ICE CONDENSER 26516.28 12.795

.0398 29.5060 TOTAL 176613.90 42 18:50s17 LOWER CONTAINMENT 46702.05 76.594

.3059 29.5130 LPPER CONTAINMENT 103401.27 71.988

.2922 29.4960 ICE CONDENSER 26508.99 12.861

.0398 29.5020 TOTAL 176612.31 43 19: 5:17 LOWER CONTAINMENT 46699.65 76.533

.2987 29.5010 LPPER CONTAINMENT 103383.99 71.932

.28E2 29.4840 ICE CONDENSER 26500.82 12.844

.0339 29.4920 TOTAL 176584.45 44 19:20:17 LOWER CONTAINMENT 46712.33 76.391

.2D55 29.4980 LPPER CONTAINMENT 103409.93 71.784

.2850 29.4800 ICE CONDENSER 26494.83 12.887

.0399 29.4880 TOTAL 176617.09 45 19335:17 LOWER CONTAINMENT 46715.22 76.355

.2307 29.4930 LPPER CONTAINMENT 103415.53 71.738

.2809 29.4750 ICE CONDENSER 26487.05 12.947

.0398 29.4830 TOTAL 176617.80 c6 19350 16 LOWER CONTAINMENT 46711.46 76.318

.2910 29.4890 LPPER CONTAINMENT 103421.67 71.693

.2787 29.4720 ICE CONDENSER 26482.47 12.946

.0399 29.4780 TOTAL 176615.60 47 20 5:16 LOWER CONTAIPOENT 46712.92 76.253

.2846 29.4800 LPPER CONTAINMENT 103427.51 71.576

.2754 29.4640 ICE CONDENSER 26478.00 12.901

.0397 29.4700 TOTAL 176618.43 48 20:20:15 LOWER CONTAIPMENT 46714.46 76.267

.2789 29.4760 LPPER CONTAINMENT 103411.48 71.624

.2723 29.4590 ICE CONDENSER 26468.73 13.002

.0397 29.4660 TOTAL 176594.67 49 20 35 15 LOWER CONTAIPMENT 46709.03 76.158

.2813 29.4690 UPPER CONTAINMENT 103432.43 71.460

.2694 29.4530 ICE CONDENSER 26464.89 12.924

.0399 29.4570 TOTAL 176606.36 50 20:50:15 LOWER CONTAIPMENT 46718.28 76.074

.2780 29.4670 UPPER CONTAINMENT 103435.64 71.428

.2663 29.4490 ICE CONDENSER 26459.87 12.982

.0398 29.4550 TOTAL 176613.79

CALCULATED VALUES BY READING PAGE RDG TIPE MASS TEMP VAP PRESS 51 21: 5:14 LOWER CONTAIPSENT 46716.14 76.059

.2752 29.4620 1.PPER CONTAINMENT 103434.97 71.393

.2634 29.4440 ICE CONDENSER 26449.79 13.082

.0398 29.4500 TOTAL 176600.90 52 21:20:14 LOWER CONTAIPOENT 46718.65 76.043

.2715 29.4590 UPPER CONTAIPMENT 103433.91 71.366

.2612 29.4400 ICE CONDENSER 26444.02 13.133

.0401-29,4470 TOTAL 176596.59 53 21335:13 LOWER CONTAINMENT 46718.10 76.004

.2710 29.4560 UPPER CONTAINMENT 103439.30 71.323

.2580 29.4360 ICE CONDENSER 26443.67 13.078

.0398 29.4430 TOTAL 17CSO1.07 54 21:50:13 LOWER CONTAINMENT 46721.78 75.893

.2697 29.4510 LPPER CONTAINPENT 103452.02 71.243

.2548 29.4320 ICE CONDENSER 26443,44 13.011

.0403 29.4390 TOTAL 176617.24 55 22 5:13 LOWER CONTAIt#ENT 46725.05 75.917

.2G34 29.4480 UPPER CONTAINMENT 103435.77 71.284

.2532 29.4280 ICE CONDENSER 26436.01 13.061

.0404 29.4340 TOTAL 176596.83 56 22:20 13 LOWER CONTAIPMENT 46731.03 75.859

.2598 29.4450 UPPER CONTAINMENT 103449.56 71.219

.2498 29.4250 ICE CONDENSER 26431.92 13.090

.0402 29.4310 TOTAL 176612.50 57 22335:13 LOWER CONTAINMENT 46727.95 75.827

.2594 29.4410 LPPER CONTAINMENT 103445.40 71.174

.2485 25.4200 ICE CONDENSER 26429.44 13.072

.0401 29.4270 TOTAL 176602.79 58 22350s12 LOWER CONTAIPMENT 46721.39 75.796

.2592 29.4350 LPPER CONTAINMENT 103455.32 71.097

.2459 29.4160 ICE CONDENSER 26426.66 13.021

.0403 29.4210 TOTAL 176603.38 59 23: 5:12 LOWER CONTAINPENT 46723.99 75.803

.2552 29.4330 UPPER CONTAINPENT 103446.43 71.150

.2435 29.4140 ICE CONDENSER 26421.39 13.082

.0404 29.4190 TOTAL 176591.81 60 23 20:12 LOWER CONTAINMENT 46725.18 75.794

.2510 29.4290 UPPER CONTAINMENT 103443.40 71.105

.2418 29.4090 ICE CONDENSER 26418.04 13.082

.0401 29.4150 TOTAL 176586.62

e

/

g-CALCULATED VALUES BY READING PAGE 7

f RDG TIME MASS TEMP VAP PRESS 61 23335:12 LOWER CONTAINMENT 46707.02 75.755

.2480 29.4250 LPPER CONTAIrelENT 103A48.14 71.045

.2388 29.4040 ICE CONDENSER 26417.75 13.020

.0403 29.4110 TOTAL 176592.90 62 23250:12 LOWER CONTAINMENT 46725.67 75.746

.2493 29.4250 UPPER CONTAINMENT 103461.88 71.043

.2361 29.4050 ICE CONDENSER 26414.98 13.054

.0403 29.4100 TOTAL 176602.53 63 0

5:12 LOWER CONTAIPMENT 46734.29 75.678

.2446 29.4220 UPPER CONTAINMENT 10346d.59 70.967

.2359 29.4020 ICE CONDENSER 26412.18 13.048

.0407 29.4070 y

TOTAL 176613.06 i

64 0 20:11 LOWER CONTAINMENT 46726.70 75.727

.2437 29.4190 LPPER CONTAINMENT 103457.03 70.999

.2328 29.3980 ICE CONDENSER 26403.75 13.135

.0407 29.4030 TOTAL 176587.48 65 0:35:11 LOWER CONTAItelENT 46721.83 75.696

.2434 29.4140 i

LPPER CONTAIPM.NT 103451.23 70.993

.2308 29.3940 ICE CONDENSER 26401.12 13.154 '.0405 29.4010 TOTAL 176574.19 66 0:50s11 LOWER CONTAINMENT 46732.36 75.630

.2385 29.4120 LPPER CONTAINMENT 103466.46 70.895

.2289 29.3910 ICE CONDENSER 26402.22 13.066

.0407 29.3970 TOTAL 176601.04 67 1: 5:11 LOWER CONTAIPMENT 46724.! 8 75.689

.2382 29.4100 LAPER CONTAIPOIENT 103456,25 70.960

.2272 29.3900 ICE CONDENSER 26400.55 13.080

.0407 29.3960 TOTAL 176581.28 6@

1:20:38 LOWER CONTAIPMENT 46735.09 75.610

.2358 29.4100 l

LPPER CONTAINMENT 103468.75 70.893

.2254 29.3880 ICE CONDENSER 26395.13 13.149

.0404 29.3940 TOTAL 176598.98' 69 1235:38 LOWER CONTADetENT 46730.53 75.616

.2343/ 29.4060 UPPER CONTAINMENT 103460.66 70.900

.2232 29.3840 ICE CONDENSER 26390.03 13.174

.0406 29.3900 TOTAL 176581.22 70 1 50:38 LOWER CONTAINMENT 46729.18 75.620

.2310 29.4020 UPPER CONTAINMENT 103461.08 70.869

.2208 29.3800 ICE CONDENilER 26390.72 13.116

.0404 29.3870 TOTAL 176580.98

l

/

C AL CLJL ATEE D VAL JMS BY READING PAGE RDG TIME "MASS TEMP VAP PRESS 71 2: 5:38 LOWER CONTAIMMENT 46723.36 75.652

.2329 29.4020 LPPER CONTAINMENT 103462.15 70.902

.2197 29.3810 ICE CONDENSER 26389.85 13.126

.0407 29.3870 TOTAL 176575.36 72 2:20:39 LOWER CONTAIl@ENT 46732.08 75.565

.2292 29.3990 l

LPPER CONTAIPMENT 103470.60 70.836

.2180 29.3780 ICE CONDENSER 26390.14 13.076

.0405 29.3840 TOTAL 176592.81 l

73 2:36:28 LO'KR CONTAINMENT 46727.87 75.570

.2285 29.3960 l

LPPER CONTAINMENT 103470.41 70.849

.2163 29.3770 ICE CONDENSER 26387.7.;3 13.096

.0405 29.3820 TOTAL 176585.50 74 2:5.1: 28 LOWER CONTAIP#ENT 46729.56 75.562

.2269 29.3950 UPPER CONTAINMENT 103461.81 70.855

.2144 29.3730 ICE CONDENSER 26381.11 13.138

.0407 29.3780 TOTAL 176572.48 75 3: 6:28 LOWER CONTAIPMENT 46732.90 75.532

.2235 29.3920 LPPER CONTAIPMENT 103473.44 70.787

.2128 29.3710 ICE CONDENSER 26373.93 13.252

.0406 29.3770 TOTAL 176580.28 76 3321:28 LOWER CONTAIPMENT 46735.93 75.602

.2228 29.3970 LPPER CONTAINMENT, 103485.33 70.823

.2115 29.3750 ICE CONDENSER 26371.66 13.324

.0406 29.3790 s

TOTAL 176592.92 77 3:36c29 LOWER CONTAINDEJ4T 46733.82 75.528

.2201 29.3890 i

LFPT.R CONTAINPENT '

103476.97 70.770

.2098 29.3680 ICE CONDENSER 26375.79 13.173

.0404 29.3740 TOTAL 176596.58 78 3351:29 LOWER CONTAIPOENT 46733.57 75.525

.2204 29.3890 LPPER CONTAIP#ENT 103472.26 70.799

.2005

29. 3k'O ICE CONDENSER 26374.09 13.185

.0406 29.3730 TOTAL 176579.91 79 4: 6:29 LOWER CONTAIPMENT 46728.94 75.573

.2177 29.3860 UPPER CONTAIPOENT 103462.00 70.826

.2069 29.3640 ICE CONDENSER 26370.54 13.198

.0407 29.3700 TOTAL 176561.49 80 4:21:29 LOWER CONTAINPENT 46730.29 75.519

.2158 29.3820 UPPER CONTAINPENT 103465.35 70.743

.2055 29.3590 ICE CONDENSER 26367.70 13.180

.0410 29.'3660 TOTAL 176563.34

i

'i

's

(

1.'

nj dn CUti : DATED V AJ__U E S

  • E W READING PAGE 9,

t 3

k

')

RDG TIME MASS TENA VAP PRESS 81 4336 29 LOWER CONTAIPMENT 46735.OC 75.493;

.2143 29.3820 LPPER CONTAINMENT 103464.83 70.751

.2043 29.3580 ICE CONDENSg'I 26365.38 13.191

.0409 29.3640

' TOTAL 176565.24

(

(

LOWER ttbYis'IPMEF.\\

82 4:51:29 46732.82 75.491

.2148 29.3810 UPPER CONTAINMENT 103^77.Bd 70.758

.3024 29.3600 i ICE CONDENSER 26367.90 13.146

.0409 29.3640 TOTAL 176577.,74 s

i t

83 5s a 30 LOWi.if CDP iT y NT 46734.98 75.510

.2103 2?.3790 LWER LD TddlMENT 103473.99 70.762

.2011 29.3580 ICE CONU :Sd 26365.21 13.161

.0409 29.3620 a.

TOTAL t, \\

176574.18 N

1, 3

(<

84 5:21:30 Lf"ER CQ4TAHgMNT 46730.51 75.493

.2110 29.3760 UAPER CONTAINMEt;T 103468.61 70.73(o

.1993 29.3530 ICE CONDONSER 26364.80 13.142

.0406 29.3600 TOTQL 176563.93 85 5:36 31 LOWER CONTAINMENT 46734.31 75.475

.2087 29.3750 LPPER CONTAINMENT 103473.72 7 0. 6 C l$

.1984 2'd.3510 ICE CONDENSER 26363.31 13.116

.0409 29.3570

[t TOTAL 176571.35

'da [" 41:31 LOWdR N NTAINMENT 46734.61 75.480

.2082 29.3750 l

UPPER CONTAINMENT 103476.6'c 70.711

.1971 29.3520 s'

ICE CONDENSER 26361.PS 13.165

.0411 29,3580 TOTAL 176572.47

+

87 6: 6:31 LOWER CONTAIPDENT 46?36.88. 75.422

.2060 29.3710 I

L544.R CONTAINMENT q' 103475.16 70.711

.955 29.3500 1CE CDMKNSER 26360.71 13.127

.0411 29.3550 TOTW 176572.75 l

88 6:21:31 LOWF!T CONTAINPENT 4G735.59 75.454

.2050 E9.2710 i,

LPPER CONTAIPMENT 103470.06 70.721

.1944 29.3480 ICE C';NDENSER 26358.95 13.143

.0410 29.3540 TOTAL 176564.61 l

09 6:36.,$2 1/.JWER CONTAIN>ENi 46733.24 75.44^

.2040 29.3680 UPPER CONTAINMEN1 103469.26 74.694

.1931 dT.3450 j

F.Ct.CONCENSE't 26354.92 11 168

.0410 P9.0510

)

,l TOTAL 176557.42

'i l

93 6351:32 LOM R CONTAINNENT 46734.59 75.450

.2029 29.3680 I

\\

3 UPPER CONTAINMENT 103468.06 70.720

.1920 29.3450

'j ICE CONDENSER 26354.56 13.157

.0410 29.3500 i

,e g ( ',

TOTAL 176557,21 i

i

\\

GALCULATED VALUES BY READING PAGE 1

RDG TIME MASS TEMP VAP PRESS 91 7: 6:32 LOWER CONTAINMENT 46735.11 75.423

.2020 29,3660 UPPER CONTAINMENT 103478.02 70.653

.1909 29.3430 ICE CONDENSER 26356.42 13.092

.0410 29.3480 TOTAL 176569.55 92 7:21:32 LOWER CONTAINMENT 46731.47 75.457

.2015 29.3650 UPOER CONTAINMENT 103473.26 70.685

.1895 29.3420 ICE CONDENSER 26349.14 13.207

.0410 29.3470 TOTAL 176553.88 93 7236333 LOWER CONTAINMENT 46731.79 75.'442

.1991 29.3620 UPPER CONTAINMENT 103479.77 70.643

.1880 29.3400 ICE CONDENSER 26350.58 13.167

.0409 29.3460 TOTAL 176562.14 94 7351:33 LOWER CONTAIPMENT 46736.92 75.435

.1972 29.3630 LPPER CONTAIPMENT 103471.75 70.682

.1871 29.339J ICE CONDENSER 26350.34 13.157

.0407 29.3450 TOTAL 176559.01 95 8: 6:33 LOWER CONTAINPENT 46729.67 75.413

.1980 29.3580 LPPER CONTAINfENT 103458.49 70.695

.1861 29.3350 ICE CONDENSER 26347.93 13.149

.0409 29.3420 TOTAL 176536.09 96 8:21:33 LOWER CONTAINMENT 46736.37 75.474

.1935 29.3610 UPPER CONTAINMENT 103469.05 70.697

.1850 29.3370 ICE CONDENSER 26348.02 13.181

.0408 29.3440 TOTAL 176553.44 97 8:36:34 LOWER CONTAIPMENT 46729.40 75.476

.1957 29.3590 UPPER CONTAIPMENT 103468.86 70.661

.1841 29.3340 ICE CONDENSER 26344.39 13.181

.0408 29.3400 TOTAL 176542.65 38 8:51:34 LOWER CONTAINMENT 46741.56 75.370

.1919 29.3570 UPPER CONTAIP#ENT 103476.56 70.631

.1825 29.3330 ICE CONDENSER 26345.17 13.136

.0408 29.3380 TOTAL 176563.29 99 9: 6:35 LOWER CONTAINMENT 46738.13 75.445

.1920 29.3590 LPPER CONTAINMENT 103479.51 70.671

.1815 29.0350 ICE CONDENSER 26335.98 13.333

.0408 29.3400 TOTAL 176553.63 l

1C0 9321:35 LOWER CONTAIPMENT 46737,12 75.491

.1911 29.3600 LPPER CONTAINMENT 103474.74 70.728

.1807 29.3360 ICE CONDENSER 26333.53 13.376

.0409 29.3400 TOTAL 176545.38

CALCULATED VALUES BY READING PAGE il RDG TIME MASS TEMP VAP PRESS 101 9:36:35 LOWER CONTAINMENT 46754.79 75.390

.!895 29.3640 UPPER CONTAIPMENT 103483.35 70.793

.1797 29.3410 ICE CONDENSER 26351.15 13.170

.0410 29.3470 TOTAL 176589.29 102 9:51:36 LOWER CONTAINMENT 46759.99 75.466

.1901 29.3720 UPPER CONTAINMENT 103475.42 70.998

.1787 29.3490 ICE CONDENSER 26355.10 13.215

.0408-29.3540 TOTAL 176590.51 103 10: 6:36 LOWER CONTAINMENT 46763.53 75.480

.1862 29.3710 UPPER CONTAINMENT 103471.21 71.032

.1780 29.3490 ICE CONDENSER 26354.36 13.243

.0409 29.3550 TOTAL 176589.09 104 10:21: 36 LOWER CONTAINMENT 46752.60 75.570

.1881 29.3710 UPPER CONTAINMENT 103440.47 71.209

.1769 29.3490 ICE CONDENSER 26349.26 13.334

.0410 29.3550 TOTAL 176542.32 105 10:36:37 LOWER CDNTAINMENT 46757.02 75.507

.1868 29.3690 UPPER CONTAINMENT 103457.63 71.103

.1759 29.3470 ICE CONDENSER 26347.09 13.310

.0408 29.3510 TOTAL 176561.74 1C6 10:51:38 LOWER CONTAINMENT 46752.11 75.501

.1841 29.3630 UPPER CONTAINMENT 103444.27 71.062

.1749 29.3400 ICE CONDENSER 26338.71 13.373

.0413 29.3460 TOTAL 176535.09 107 11: 6:38 LOWER CONTAINMENT 46741.48 75.562

.1855 29.3610 UPPER CONTAINMENT 103431.84 71.083

.1743 29.3370 ICE CONDENSER 26328.47 13.511

.0412 29.3430 TOTAL 176501.79 108 11:21:39 LDWER CONTAINMENT 46749.09 75.488

.1837 29.3600 UPPER CONTAINMENT 103459.74 70.939

.1734 29.3360 ICE CONDENSER 26323.37 13.586

.0412 29.3420 TOTAL 176532.20 109 11:36: 40 LOWER CONTAINMENT 46744.4E 75.481

.1830 29.3560 UPPER CONTAINMENT 103473.12 70.868

.1725 29.3350 ICE CONDENSER 26316.69 13.641

.0412 29.3380 TOTAL 176534.26 110 11:51:43 LDWER CONTAINMENT 46750.02 75.448

.1824 29.3570 UPPER CONTAINMENT 103484.82 70.819

.1719 29.3350 ICE CONDENSER 26314.21 13.680

.0416 29.3380 TOTAL 176549.05 l

CALCULATED VALUES BY READING PAGE 1

RDG TIME MASS TEMP VAP PRESS 111 12: 6: 44 LOWER CONTAINMENT 46760.12 75.357

.f800 29.3560 UPPER CONTAINMENT 103506.55 70.674

.1707 29.3320 ICE CONDENSER 26314.72 13.652

.0417 29.3370 TOTAL 176581.40 112 12:21:44 LOWER CONTAINMENT 46758.43 75.380

.1818 29.3580 UPPER CONTAINMENT 103508.68 70.711

.1701 29.3340 ICE CONDENSER 26307.91 13.795

.0415 29.3380 TOTAL 176575.03 113 12:36:45 LOWER CONTAINMENT 46754.24 75.424

.1780 29.3540 UPPER CONTAINMENT 103499.32 70.681

.1634 29.3290 ICE CONDENSER 26301.85 13.854

.0415 29.3350 TOTAL 176555.41 114 12:51:46 LOWER CONTAINMENT 46750.66 75.449

.1799 29.3550 UPPER CONTAINMENT 103504.29 70.693

.1683 29.3300 ICE CONDENSER 26299.57 13.864

.0415 29.3330 TOTAL 176554.52 115 13: 6:46 LOWER CONTAINMENT 46759.70 75.514

.1767 29.3610 UPPER CONTAIPMENT 103495.87 70.876

.1677 29.3370 ICE CONDENSER 26300.92 14.000

.0416 29.3430 TOTAL 176556.49 116 13:21:47 LOWER CONTAINMENT 46778.57 75.518

.1767 29.3730 UPPER CONTAINMENT 103491.08 71.115

.1668 29.3480 ICE CONDENSER 26303.94 14.121

.0417 29.3540 TOTAL 176573.59 117 13:36:48 LDWER CONTAINMENT 46777.85 75.422

.1764 29.3670 LPPER CONTAINPENT 103476.47 71.092

.1662 29.3420 ICE CONDENSER 26300.77 14.085

.0415 29.3480 TOTAL 176555.08 118 13:51:49 LDWER CONTAINMENT 46762.94 75.555

.1755 29.3640 UPPER CONTAIPMENT 103467.99 71.166

.1655 29.3430 ICE CONDENSER 26291.35 14.222

.0415 29.3460 TOTAL 176522.19 119 14: 6:50 LDWER CONTAINMENT 46764.44 75.482

.1745 29.3600 UPPER CONTAINMENT 103484.87 71.006

.1646 29.3380 ICE CONDENSER 26288.15 14.194

.0418 29.3410 TOTAL 176537.46 120 14:21:50 LDWER CONTAINMENT 46755.00 75.569

.1756 29.3600 UPPER CONTAINMENT 103482.87 70.989

.1641 29,3360 ICE CONDENSER 26281.27 14.322

.0415 29.3410 l

TOTAL 176519.14 l

l

)

C ALCUL. ATED VALUES BY READING PAGE 13 RDG TIME MASS TEMP VAP PRESS 121 14:36:52 LOWER CONTAINMENT 46752.71 75.611

.2748 29.3600 UPOER CONTAINMENT 103494.67 70.997

.1633 29.3390 ICE CONDENSER 26277.01 14.430

.0416 29.3430 TOTAL 176524.39

&22 14:51:53 LOWER CONTAINMENT 46761.35 75.536

.1725 29.3590 UPPER CONTAINMENT 103515.33 70.867

.1627 29.3370 ICE CONDENSER 26278.36 14.403

.0418 29.3430 TOTAL 176555.03 123 15: 6:54 LOWER CONTAINMENT 46751.43 75.565

.1731 29.3550 UPPER CONTAINMENT 103495.44 70.922

.1622 29.3340 ICE CONDENSER 26270.56 14.479

.0417 29.3390 TOTAL 176517.44 124 15:21:54 LOWER CONTAINMENT 46760.69 75.'480

.1719 29.3550 UPPER CONTAINMENT 103519.32 70.832

.1615 29.3350 ICE CONDENSER 26269.59 14.497

.0418 29.3390 TOTAL 176549.61 125 15:36:55 LOWER CONTAINMENT 46761.12 75.476

.1709 29.3540 UPPER CONTAINMENT 103516.42 70.802

.1609 29.3320 ICE CONDENSER 26269.98 14.445

.0415 29.3360 TOTAL 176547.51 126 15:51:56 LOWER CONTAINMENT 46754.68 75.504

.1714 29.3520 UPPER CONTAINMENT 103511.61 70.789

.1600 29.3290 ICE CONDENSER 26268.02 14.441

.0420 29.3340 TOTAL 176534.30 127 16: 6:57 LOWER CONTAINMENT 46761.03 75.462

.1697 29.3520 UPPER CONTAINMENT 103524.68 70./31

.1595 29.3290 ICE CONDENSER 26265.28 14.459

.0419 29.3320 TOTAL 176550.96 128 16:21:58 LOWER CONTAINMENT 46765.52 75.395

.1686 29.3500 L.PPER CONTAIPPENT 103535.69 70.654

.1586 29.3270 ICE CONDENSER 26266.69 14.416

.0420 29.3310 TOTAL 176567.90 129 16:36:59 LOWER CONTAINMENT 46756.42 75.434

.1691 29.3470 UPPER CONTAINMENT 103518.28 70.678

.1582 29.3230 ICE CONDENSER 26262.46 14.445

.0419 29.3280 TOTAL 176537.15 830 16:52: 0 LOWER CONTAINMENT 46756.49 75.501

.1674 29.3490 UPPER CONTAINMENT 103509.73 70.754

.1574 29.3240 ICE CONDENSER 26259.62 14.510

.0420 29.3290 TOTAL 176525.84

CALCULATED VALUES BY READING PAGE d

RDG TIME MASS TEMP VAP PRESS 131 17: 7: 1 LOWER CONTAINMENT 46758.19 75.436

.!659 29.3450 UPPER CONTAIPMENT 103511.71 70.720

.1568 29.3220 ICE CONDENSER 2G258.98 14.468

.0423 29.3260 TOTAL 176528.89 l

132 17:22: 2 LOWER CONTAINMENT 46750.10 75.566

.1669 29.3480 UPPER CONTAINMENT 103493.61 70.834

.1566 29.3230 ICE CONDENSER 26254.25 14.605

.0422 29.3290 TOTAL 176497.97 133 17:37: 3 LOWER CONTAINMENT 46751.11 75.530

.1662 29.3460 i

UPPER CONTAINMENT 103515.05 70.735

.1560 29.3230 ICE CONDENSER 26256.16 14.553

.0423 29.3280 TOTAL 176522.32 134 17:52: 4 LOWER CONTAINMENT 46751.22 75.553

.1655 29.3450 UPPER CONTAINMENT 103509.68 70.756

.1553 29.3220 ICE CONDENSER 26253.44 14.587

.0422 29.3270 TOTAL 176514.33 135 18: 7: 5 LOWER CONTAINMENT 46753.11 75.497

.1647 29.3440 UPPER CONTAINMENT 103531.14 70.675

.1547 29.3230 ICE CONDENSER 26255.47 14.566

.0422 29.3280 TOTAL 176539.73 836 18:22: 5 LOWER CONTAINMENT 46750.52 75.478

.1644 29.3410 LPPER CONTAIPMENT 103517.07 70.682

.1543 29.3190 ICE CONDENSER 26249.51 14.609

.0422 29.3240 TOTAL 176517.11 137 18:37: 6 LOWER CONTAINMENT 46748.04 75.491

.1643 29.3400 UPPER CONTAINMENT 103524.49 70.658

.1536 29.3190 ICE CONDENSER 26249.02 14.601

.0423 29.3230 TOTAL 176521.55 138 18:52: 7 LOWER CONTAINMENT 46753.12 75.463

.1646 29.3420 LPPER CONTAINMENT 103533.63 70.620

.1531 29.3190 ICE CONDENSER 26252.29 14.556

.0424 29.3240 TOTAL 176539.04 139 19: 7: 8 LOWER CONT AINMENT 46754.44 75.515

.1619 29.3430 LPPER CONTAINMENT 103517.06 70.729

.1527 29.3200 ICE CONDENSER 26247.03 14.651

.0424 29.3240 TOTAL 176518.53 140 19:22: 8 LOWER CONTAINMENT 46755.41 75.489

.1618 29.3420 UPPER CONTAIPMENT 103532.85 70.642

.1521 29.3190 ICE CONDENSER 26245.65 14.659

.0425 29.3230 TOTAL 176533.90

CALCULATED VALUES BY READING PAGE 15 RDG TIME MASS TEMP VAP PRESS A41 19337: 9 LOWER CONTAINMENT 46759.14 75.467

.1616 29.3430 UPPER CONTAIP#ENT 103535.83 70.632

.1518 29.3190 ICE CONDENSER 26243.06 14.722

.0424 29.3240 TOTAL 176538.04 142 19:52:11 LOWER CONTAIP#ENT 46761.70 75.460

.1604 29.3430 UPPER CONTAINPENT 103554.70 70.565

.1512 29.3200 ICF. CONDENSER 26247.92 14.653

.0423 29.3250 TOTAL 176564.32 143 20: 7:11 LOWER CONTAIPMENT 46757.11 75.471

.1607 29.3410 UPPER CONTAIPMENT 103541.62 70.590

.1505 29.3170 ICE CONDENSER 26241,78 14.680

.0425 29.3200 TOTAL 176540.51 144 20 22:13 LOWER CONTAIPMENT 46756.71 75."Sb6

.1600 29.3420 UPPER CONTAIPMENT 103527.85 70.665

.1502 29.3170 ICE CONDENSER 26241.48 14.702

.0424 29.3210 TOTAL 176526.04 145 20:37:14 LOWER CONTAINMENT 46760.12 75.514

.1595 29.3440 LPPER CONTAIPMENT 103533.16 70.666

.1497 29.3180 ICE CONDENSER 26240.53 14.738

.0423 29.3220 TOTAL 176533.82 146 20:52:15 LOWER CONTAIPMENT 46757.06 75.478

.1593 29.3400 4

UPPER CONTAIPMENT 103538.30 70.594

.1492 29.3150 1

ICE CONDENSER 26239.05 14.713

.0425 29.3190 TOTAL 176534.42 147 21: 7:15 LOWER CONTAIP4ENT 46754.71 75.528

.1581 29.3400 UPPER CONTAIPMENT 103523,29 70.681

.1487 29.3150 ICE CONDENSER 26232.96 14.856

.0425 29.3210 TOTAL 176510.96 148 21:22:16 LOWER CONTAIPOENT 46747.99 75.605

.1581 29.3400 UPPER CONTAINMENT 103523.93 70.705

.1481 29.3160 ICE CONDENSER 26228.91 14.929

.0424 29.3210 TOTAL 176500.84 149 21:37 17 LOWER CONTAIPDENT 46754.19 75.573

.1569 29.3410 UPPER CONTAINPENT 103527.90 70.672

.1478 29.3150 ICE CONDENSER 26232.41 14.872

.0411 29.3200 TOTAL 176514.50 150 21352:18 LOWER CONTAIP4ENT 46756.13 75.517

.1568 29.3390 LFPER CONTAINMENT 103522.45 70.691

.1473 29.3140 ICE CONDENSER 26236.21 14.823

.0389 29.3190 TOTAL 176514.78 1

QA L C U L A *T* EE D VALUES BY READING PAGE G

RDG TIME MASS TEMP VAP PRESS 151 22: 7 19 LOWER CONTAIPMENT 46749.10 75.569

.1573 29.3380 UPPER CONTAINPEENT 103522.73 70.676

.1471 29.3130 ICE CONDENSER 26232.26 14.868

.0395 29.3180 TOTAL 176504.09 152 22:22:20 LOWER CONTAIPMENT 46751.76 75.509

.T 29.3350 UPPER CONTAIPMENT 103534.42 70.625 29.3130 ICE CONDENSER 26230.43 14.875 1

29.3180 TOTAL 176516.62 153 22:37:22 LOWER CONTAINMENT 46755.24 75.578

.1550 29.3400 UPPER CONTAINMENT 103536.90 70.673

.1462 29.3160 ICE CONDENSER 26229.13 14.911

.0423 29.3200 TOTAL 176521.27 154 22e52:23 LOWER CONTAIPMENT 46748.92 75.'587

.1555 29.3370 UPPER CONTAINMENT 103528.19 70.690

.1457 29.3140 ICE CONDENSER 26227.26 14.924

.0426 29.3190 TOTAL 176504.36 155 23: 7 25 LOWER CONTAINMENT 46746.56 75.576

.1555 29.3350 LppER CONTAIPMENT 103526.84 70.648

.1454 29.3110 ICE CONDENSER 26225.71 14.900

.0428 29.3160 TOTAL 176499.12 856 23:22:25 LOWER CONTAIPMENT 46750.20 75.558

.1542 29.3350 UPDER CONTAINMENT 103529.67 70.643

.1449 29.3110 ICE CONDENSER 26224.38 14.910

.0427 29.3150 TOTAL 176504.25 A57 23:37:26 LOWER CONTAIPOENT 46746.14 75.558

.1548 29.3330 LPPER CONTAIPMENT 103530.26 70.611

.1445 29.3090 ICE CONDENSER 26224.43 14.873

.0429 29.3130 TOTAL 176500.83 158 23:52:27 LOWER CONTAIP#ENT 46749.49 75.554

.1539 29.3340 UPPER CONTAINMENT 103532.40 70.626

.1441 29.3100 ICE CONDENSER 26224.32 14.909

.0428 29.3150 TOTAL 176506.22 159 0: 7:28 LOWER CONTAINPENT 46744.80 75.647

.1527 29.3350 i

LPPER CONTAINPENT 103521.96 70.702

.1438 29.3110 ICE CONDENSER 26220.94 14.986

.0428 29.3160 TOTAL 176487.70 160 0:22:29 LOWER CONTAIPMENT 46751.48 75.575

.1525 29.3350 UPPER CONTAINMENT 103535.18 70.606

.1434 29.3090 ICE CONDENSER 26220.12 14.952

.0429 29.3130 TOTAL 176506.77 l

CALCULATED VALUES BY READING PAGE 1 '7 RDG TIME MASS TEMP VAP PRESS a6a 0:37:30 LOWER CONTAIPMENT 46754.05 75.515

.1522 29.3330 UPPER CONTAINMENT 103530.90 70.616

.1431 29.3080 ICE CONDENSER 26220.68 14.946

.0426 29.3130 TOTAL 176505.63 162 0:52:32 LOWER CONTAIPMENT 46753.37 75.524

.1521 29.3330 UPPER CONTAINMENT 103529.67 70.650

.1425 29,3090 ICE CONDENSER 26222.47 14.926

.0429 29.3140 TOTAL 176505.50 163 1: 7:33 LOWER CONTAIPMENT 46748.46 75.551

.1517 29.3310 UPPER CONTAINMENT 103532.44 70.626

.1421 29.3080 ICE CONDENSER 26217.90 14.960

.0428 29.3110 TOTAL 176498.80 164 1:22:34 LCWER CONTAIPMENT 46749.22 75.S' 1

.1512 29.3310 5

UPPER CONTAINPENT 103527.80 70.618

.1418 29.3060 ICE CONDENSER 26213.66 15.033

.0431 29.3110 TOTAL 176490.68 1

165 1:37:35 LOWER CONTAINMENT 46749.89 75.535

.1517 23.3310 LPPER CONTAIPMENT 103532.89 70.618

.1414 23.3070 ICE CONDENSER 26214.77 15.001

.2428 29.3100 TOTAL 176497.55 166 1:52:36 LOWER CONTAINMENT 46747.11 75.572

.1514 29.3310 LPPER CONTAIP4ENT 103521.04 70.666

.1411 29.3060 ICE CONDENSER 26213.77 15.019

.0428 29.3100 TOTAL 176481.92 167 2: 7:37 LOWER CONTAIPMENT 46746.44 75.563

.1513 29.3300 LPPER CONTAINPENT 103524.35 70.656

.1407 29.3060 ICE CONDENSER 26216.83 14.973

.0432 29.3110 TOTAL 176487.62 l 168 2:22 38 LOWER CONTAIP#ENT 46747.74 75.591

.1510 29.3320 UPPER CONTAIP4ENT 103536.55 70.655

.1403 29.3090 ICE CONDENSER 26217.77 15.011

.0429 29.3140 TOTAL 176502.06 169 2:37: 41 LOWER CONTAIPMENT 46749.63 75.586

.1491 29.3310 UPPER CONTAIPMENT 103526.81 70.673

.1401 29.3070 ICE CONDENSER 26212.68 15.053

.0430 29.3110 TOTAL 176489.11 l 170 2:52: 42 LOWER CONTAINMENT 46750.41 75.582

.1488 29.3310 l

UPPER CONTAIPMENT 103536.01 70.598

.1396 29.3050 ICE CONDENSER 26210.79 15.071

.0429 29.3100 TOTAL 176497.21

CALCULATED VALUES BY READING PAGE 1

l CDG TIME MASS TEMP VAP PRESS 171 3: 7: 43 LDWER CONTAINMENT 46758.37 75.510

.2498 29.3330 UPPER CONTAINMENT 103534.35 70.650

.1392 29.3070 ICE CONDENSER 26206.75 15.164

.0427 29.3110 TOTAL 176499.47 172 3:22:44 LOWER CONTAINMENT 46750.73 75.587

.1493 29.3320 UPPER CONTAIt#4ENT 103529.52 70.663

.1389 29.3060 ICE CONDENSER 36204.89 15.194

.0430 29.3110 TOTAL 176485.15 173 3:37:45 LOWER CONTAINMENT 46756.79 75.507

.1489 29.3310 UPPER CONTAINMENT 103530.29 70.627

.1386 29.3040 ICE CONDENSER 26208.76 15.070

.0433 29.3080 TOTAL 176495.84 174 3:52:47 LOWER CONTAINMENT 46742.50 75.-655

.1488 29.3300 UPPER CONTAINMENT 103520.14 70.704

.1383 29.3050 ICE CONDENSER 26203.33 15.187

.0431 29.3090 TOTAL 176465.97 175 4

7:48 LOWER CONTAINMENT 46745.69 75.669

.1480 29.3320 LPPER CONTAINMENT 103520.64 70.706

.1380 29.3050 ICE CONDENSER 26204.66 15.197

.0430 29.3110 l

TOTAL 176470.98 I

176 4:22:50 LOWER CONTAINMENT 46739.56 75.652

.1477 29.3270 UPPER CONTAINMENT 103523.43 70.642

.1378 29.3020 ICE CONDENSER 26200.77 15.202

.0431 29.3070 TOTAL 176463.77 177 4: 37:51 LOWER CONTAINMENT 46741.21 75.675

.1475 29.3290 UPPER CONTAINMENT 103522.36 70.653

.1374 29.3020 ICE CONDENSER 26200.31 15.206

.0433 29.3070 TOTAL 176463.89 178 4:52:53 LOWER CONTAINMENT 46734.48 75.678

.1475 29.3250 UPPER CONTAINMENT 103517.65 70.665

.1371 29.3010 ICE CONDENSER 26201.68 15.151

.0431 29.3050 TOTAL 176453.81 179 5: 7:54 LOWER CONTAINMENT 46741.83 75.695

.1470 29.3300 UPPER CONTAINPENT 103532.47 70.682

.1370 29.3060 ICE CONDENSER 26203.17 15.206

.0431 29.3100 TOTAL 176477.47 180 5:22:55 LOWER CDNTAINMENT 46745.02 75.627

.1477 29.3290 UPPER CONTAINMENT 103535.74 70.646

.1370 29.3050 ICE CONDENSER 26204.48 15.181

.0432 29.3100 TOTAL 176485.25 i

CALCULATED VALUES BY READING PAGE 19 RDG TIME MASS TEMP VAP PRESS 18&

5 37:56 LOWER CONTAINMENT 46744.56 75.G30

.1468 29.3280 UPPER CONTAINMENT 103528.25 70.674

.1366 29.3040 ICE CONDENSER 26203.46 15.183

.0432 29.3090 TOTAL 176476.27 1@2 5352:58 LOWER CONTAIPDENT 46748.99 75.606

.1464 29.3290 l

UPPER CONTAIP# TENT 103539.95 70.655

.1364 29.3060 ICE CONDENSER 26205.59 15.173

.0434 29.3110 TOTAL 176494.52 183 6: 8: O LOWER CONTAIPetENT 46752.74 75.576

.1457 29.3290 UPPER CONTAINMENT 103534.96 70.667

.136; 29.3050 ICE CONDENSER 26203.59 15.162

.0434 29.3080 TOTAL 176491.29 884 6:23 1

LOWER CONTAIP# TENT 46741.94 75."665

.1465 29.3290 UPPER CONTAINMENT 103521.02 70.722

.1360 29.3040 ICE CONDENSER 26200.40 15.237

.0433 29.3090 TOTAL 176463.36 A85 6 38 2

LOWER CONTAIPe8ENT 46742.98 75.637

.1455 29.3260 UDPER CONTAINM:ENT 103525.95 70.663

.1359 29.3020 ICE CONDENSER 26199.82 15.197

.0434 29.3060 TOTAL 176468.75 186 6:53: 4 LOWER CONTAINPiENT 46750.62 75.592

.1451 29.3280 UPPER CONTAIP4ENT 103552.32 70.568

.1357 29.3040 ICE CONDENSER 26203.29 15.155

.0431 29.3070 l

TOTAL 176506.23

&87 7: 8: 5 LOWER CONTAIP# TENT 46752.83 75.527

.1453 29.3260 LPPER CONTAINMENT 103545.79 70.534

.1354 29.3000 ICE CONDENSER 26204.02 15.121

.0434 29.3060 TOTAL 176502.64 l

188 7323: 6 LOWER CONTAIPOIENT 46741.93 75.686

.1454 29.3280 UPPER CONTAINMENT 103523.33 70.710

.1350 29.3030 ICE CONDENSER 26191.69 15.362

.0434 29.3070 TOTAL 176456.9*

189 7338: 7 LOWER CONTAIPDENT 46737.87 75.693

.1446 29.3250 UPPER CONTAINMENT 103518.17 70.668

.1348 29.2990 ICE CONDENSER 26190.65 15.348

.0434 29.3050 TOTAL 176446.69 690 7:53: 9 LOWER CONTAIP9 TENT 46745.21 75.643

.1447 29.3270 UPPER CONTAINMENT 103535.97 70.635

.1346 29.3020 ICE CONDENSER 26195.67 15.284

.0437 29.3070 TOTAL 176476.85 l

CALCUL.ATED VALUES BY READING PAGE a

RDG TIME MRSS TEMP VAP PRESS 191 8: 8:10 LOWER CONTAINMENT 46738.90 75.718

.1446 29.3270 UPPER CONTAINMENT 103523.45 70.703

.1344 29.3020 ICE CONDENSER 26193.46 15.329

.0434 29.3070 TOTAL 176455.81 192 8:23:12 LOWER CONTAINMENT 46738.82 75.720

.1435 29.3260 1

UPPER CONTAINMENT 103525.68 70.678

.1341 29.3010 ICE CONDENSER 26192.90 15.323

.0434 29.3060 TOTAL 176457.40 193 8:38:13 LOWER CONTAINMENT 46743.38 75.640

.1431 29.3240 UPPER CONTAINMENT 103536.50 70.588

.1340 29.2990 ICE CONDENSER 26193.55 15.279

.0433 29.3040 TOTAL 176473.42 194 8:53:14 LOWER CONTAINMENT 46740.75 75."703

.1432 29.3260 UPPER CONTAINMENT 103525.53 70.670

.1336 29.3000 ICE CONDENSER 26187.90 15.405

.0429 29.3050 TOTAL 176454.18 195 9: 8:15 LOWER CONTAINMENT 46735.43 75.750

.1430 29.3250 UPPER CONTAIPMENT 103528.97 70.711

.1334 29.3030 ICE CONDENSER 26187.99 15.489

.0407 29.3080 TOTAL 176452.39

&96 9:23:16 LOWER CONTAINMENT 46738.28 75.707

.1435 29.3250 UPPER CONTAINMENT 103526.72 70.655

.1331 29.2990 ICE CONDENSER 26186.70 15.489

.0391 29.3050 TOTAL 176451.70 197 9:38:17 LOWER CONTAINMENT 46740.17 75.671

.1423 29.3230 UPPER CONTAINMENT 103522.57 70.681

.1328 29.2990 ICE CONDENSER 26189.27 15.382

.0408 29.3030 TOTAL 176452.00 198 9:53:19 LOWER CONTAINMENT 46740.43 75.683

.1425 29.3240 UPPER CONTAINMENT 103537.86 70.641

.1327 29.3010 ICE CONDENSER 26191.04 15.353

.0426 29.3050 TOTAL 176469.32 199 10: 8:21 LOWER CONTAINMENT 46735.36 75.689

.1423 29.3210 UPPER CONTAINMENT 103524.72 70.640

.1325 29.2970 ICE CONDENSER 26187.83 15.347

.0436 29.3020 TOTAL 176447.91 200 10:23:22 LOWER CONTAINMENT 46735.24 75.704

.1416 29.3210 UPPER CONTAINMENT 103516.62 70.701

.1324 29.2980 ICE CONDENSER 26184.61 15.421

.0436 29.3030 TOTAL 176436.47

i CALCULATED VALUES BY READING PAGE e1 RDG TIME MASS TEMP VAP PRESS 201 10:38:24 LOWER CONTAINMENT 46732.37 75.785

.I420 29.3240 UPPER CONTAINMENT 103518.02 70.719

.1320 29.2990 ICE CONDENSER 26182.23 15.464

.0436 29.3030 TOTAL 176432.61 202 10:55: 0 LOWER CONTAINMENT 46737.51 75.696

.1426 29.3230 UPPER CONTAINMENT 103527.16 70.677

.1318 29.2990 ICE CONDENSER 26186.23 15.405

.0437 29.3040 TOTAL 176450.35 223 1;t10: 2 LOWER CONTAINMENT 46742.60 70.663

.141.

23.3240 UPPER CONTAINMENT 103529.20 70.666

.4317 23.2390 ICE CONDENSER 26184.85 15.395

.2439 29.3020 TOTAL 176456.65 204 11:25: 4 LOWER CONTAINMENT 46734.03 75.658

.1417 23.3200 UPPER CONTAINMENT 103520.77 70.Ge5

.;J13 29.2354 ICE CONDENSER 26182.55 15.386

.e440 29.2330 TOTAL 176437.41 203 A1:40:36 LOWER CONTAINMENT 46735.51 75.636

.2406 29.3200 UPPER CONTAINMENT 103513.83 70.6*6

.1313 29.2360 ICE CONDENSER 16183.2; 15.366

.2443 23.3300 TOTAL 176442.56 206

&l:55:37 LOWER CONTAINMENT 46735.6G 75.645

. ~74 23.3170 UPPER CONTAINMENT 103525.35 70.610

.1308 29.2340 ICE CONDENSER 26182.66 15.067

.0*33 29.2360 TOTAL 176444.60 207 A2:10:38 LOWER CONTAINMENT 46733.06 75.714

.;434 29.3200 UPPER CONTAINMENT 103519.35 70.680

.1308 29.2360 ICE CONDENSER 26178.46 15.481

.0436 29.3000 TOTAL 176,30.88 206 12:25: 40 LOWER CONTAINMENT 46733.38 75.631

.1406 29.3190 UPPER CONTAINMENT 103506.55 70.676

.1306 29.2920 ICE CONDENSER 26176.53 15.449

.0436 29.2380 TOTAL 176425.11 203 12: 40:42 LOWER CONTAINMENT 46733.51 75.660

.a401 29.3160 UPPER CONTAINMENT 103511.40 70.641

.1302 29.2310 ICE CONDENSER 26178.66 15.426

.0433 29.2370 TOTAL 176423.57

,210 12:55:43 LOWER CONTAINMENT 46727.84 75.682

.1394 29.3130 i

UPPER CONTAINMENT 103503.39 70.647

.1301 29.2890 i

ICE CONDENC2R 26176.08 15.424

.0440 29.2940 l

TOTAL 176407.31 I

CALCULATED V AL_ U ES BY READING PAGE 2

RDG TIME MASS TEMP VAP PRESS 211 13: 5: 41 LOWER CONTAINMENT 46729.34 75.675

.2399 29.3140 UPPER CONTAINMENT 103506.29 70.635

.1300 29.2893 ICE CONDENSER 26175.88 15.429

.0439 29.2940 TOTAL 176411.51 212 13:15:42 LOWER CONTAINMENT 46731.76 75.680

.1391 29.3150 UPPER CONTAINMENT 103511.27 70.647

.1299 29.29.0 ICE CONDENSER 26173.92 15.463

.0440-29.2940 TOTAL 176416.95 213 13:25:43 LOWER CONTAINMENT 46725.57 75.660

.1400 29.31..

UPPER CONTAINMENT 103502.29 70.622

.1296 29.2570 ICE CONDENSER 26168.34 15.535

.0436 29.2920 TOTAL 176396.20 214 13:35:43 LOWER CONTAINMENT 46727.47 7 5.' 7 0 1

.1357 29.3140 UPPER CONTAINMENT 103501.21 70.649

.1296 29.2680 ICE CONDENSER 26169.16 15.531

.0441 29.L330 TOTAL

.76337.84 2;5 13:45: 43 LOWER CONTAINMENT 46724.5i 75.713

.1398 29.3137 UPPER CONTAINMENT 103500.57 70.691

.1295 29.2900 ICE CONDENSER 26167.81

5.572

.0436 23.2340 TOTAL 176392.69 21G 13:55:44 LOWER CONTAINMENT 46730.97 75.647

.1334 29.3132 UPPER CONTAINMENT

  • 0350;.66 70.633

.1293 29.2570 ICE CONDENSER 26171.51 15.492

.2439 29.2930 TOTAL 176404.16 217 14: 5: 44 LOWER CONTAINMENT 46723.43 75.731

.1385 29.3;2i.

UPPER CONTAINMENT 103494.75 70.690

.1292 29.2662 ICE CONDENSER 26166.So

.s.524

.0442 23.2310 TOTAL 176386.76 2'8 1-ti5: 45 LOWER CONTAINMENT 46722.30 75.692

.;390 29.3100 UPPER CONTAINMENT 103436.98 70.643

.1291 29.2860 ICE CONDENSER 26169.54

5.495

.0439 29.2910 TOTAL 176389.43 213 14:25:45 LOWER CONTAINMENT 46723.59 75.677

.1394 29.3120 UPPER CONTAINMENT 103490.56 70.643

.1290 29.2842 ICE CONDENSER 26167.16 15.505

.0440 29.2S90 TOTAL 176381.3; 220 14;35:47 LOWER CONTAINMENT 46727.65 75.682

.1386 29.3120 UPPER CONTAINMENT 103495.68 70.672

.1289 29.2670 ICE CONDENSER 26165.12 10.553

.0443 29.2900 TOTAL 176386.e*

l CALCULATED VALUES BY READING I:8 AGE i22 3 RDG TIME MASS TEMP VAP PRESS dai 4:45: 48 LOWER CONTAINMENT 46727.40 75.600

.i265 2 3. 3.t 00 UPPER CONTAINMENT 103456.12 70.658

.1288 29.2640 ICE CONDENSER 26166.37 15.520

.0439 29.2690 TOTAL 17638;.69 222 14: 55:49 LOWER CONTAINMENT 46716.47 75.674

.1367 29.2..J UPPER CONTAINMENT 103491.36 70.643

.1287 29.4340 ICE CONDENSER 26163.40 15.572

.0442 29.2696 TOTAL 1763ai.03 123 25: 5:49 LOWER CONTAINMENT 46720.93 75.710

.43BI 23.CiO2 UPPER CONTAINMENT 103480.56 70.701

.i266 23.26~1 ICE CONDENSER 26154.79 15.7;4

.0433 2?.. 362 TOTAL 176356.36 li4 15:10:50 LOWER CONTAINMENT 46726.67 75.-660

. 080 25.0;00 UPPER CONTAINMENT 103491.60 70.EEG

.1263 25.1634 ICE CONDENSER 26156.60

.5.656

.0443 19.2570 TOTAL 176376.07 C25 15:45:51 LOWER CONTAINMENT 46721.30 75.694

.;03E 29.0032 UPPER CONTAINMENT 103492.02 70.632

.;262 29.2G34 ICE CONDENSER 2615G.83 10.673

.044C 19.2G62 TOTAL 176371.13 226 85:35:52 LOWER CONTAINMENT 46,7a3. 00 72.654

. 360 I?.Ci?O UPPER CONTAINMENT 103479.25 70.643

.4131 13.4630 ICE CONDENSER 16133.36

C.61;

.0440 13.2630 TOTAL 176357.63 227 15: 45:52 LOWER CONTAINMENT 467;3.24 7L.674

.42S2 29.326 UPPER CONTAINMENT 103464.Ia 70.687

.1279 23.2750 ICE CONDENSER 26104.96 15.612

.2440 29.2G10 3

TOTAL 176338.47 l228 16: 0:26 LOWER CONTAINMENT 46717.97 75.704

.1384 d9.3070 t

UPPER CONTAINMENT 103476.0E 70.655

.1178 29.2800 ICE CONDENSER 26157.75 15.592

.044; 19.2840 TOTAL

76353.75 i 229 16
15:28 LOWER CONTAINMENT 46717.16 75.626

.1382 29.3000 UPPER CONTAINMENT 103479.66 70.539

.1277 29.2740 ICE CONDENSER 26156.28 15.522

.0441 29.2762 TOTAL 176353.30 230 16:30:29 LOWER CONTAINMENT 46688.99 75.588

.1368 29.2610 UPPER CONTAINMENT 103400.80 70.565

.1275 29.2530 ICE CONDENSER 26136.10 15.529

.0442 29.25tv i

TOTAL 176225.90 i

J

CALCULATED VALUES BY READING PAGE RDG TIME MASS TEMP VAP PRESS II:

16:45:30 LOWER CONTAINMENT 464G8.03 75.509

.f370 29.1390 UPPER CONTAINMENT 102946.44 70.330

.1268 29.1120 ICE CONDENSER 26012.71 15.500

.0439 29.1160 TOTAL 175429.18 232 17: 0:30 LOWER CONTAINMENT 46173.75 75.475

.1355 28.9522 UPPER CONTAINMENT 102330.54 70.074

.1257 28.9230 ICE CONDENSER 25846.71 15.438

.0442 28.927C TOTAL 174350.99 233 17: 25:32 LOWER CONTAINMENT 45879.52 75.364

.1351 26.7223 UPPER CONTAINMENT 101684.72 69.936

.1249 28.7330 ICE CONDENSER 25679.17 15.364

.0436 28.7360 TOTAL 173243.42 234 17:30:32 LOWER CONTAINMENT 45571.20 75,307

.;343 26.5700 UPPER CONTAINMENT 101007.01 69.928

.1240 26.5410 ICE CONDENSER 25507.90 15.412

.0433 28.546C TOTAL 172086.10 1

235 17: 45:33 LDWER CONTAINMENT 45261.35 75.375

.1332 2G.3750 UPPER CONTAINMENT 100342.32 69.815

.1230 26.3470 ICE CONDENSER 25337.06 15.408

.0395 28.351C TOTAL 170940.73 236 18: 0:33 LOWER CONTAINMENT 44942.11 75.388

. 327 26.1760 UPPER CONTAINMENT 99643.09 69.787

.1222 28.1400 ICE CONDENSER 25156.79

5.444

.0387 28.;5:0 TOTAL 169741.99 237 18:15:33 LOWER CONTAINMENT 44625.45 75.304

.1317 27.9730 UPPER CONTAINMENT 98933.34 69.698

.1214 27.9430 ICE CONDENSER 24975.17 15.388

.0410 27.9470 TOTAL 168533.96 238 18:30:34 LOWER CONTAINMENT 44292.21 75.329

.1313 27.7660 UPPER CONTAINMENT 98203.70 69.678

.1207 27.7360 ICE CONDENSER 24786.81 15.422

.0425 27.7400 TOTAL 167282.72 239 18: 45:34 LOWER CONTAINMENT 43950.49 75.334

.1303 27.5520 UPPER CONTAINMENT 97465.01 69.612

.1198 27.5240 ICE CONDENSER 24598.29 15.355

.0430 27.5260 TOTAL 166013.78 240 19: 0:34 LOWER CONTAINMENT 43606.28 75.307

.1294 27.3350 UPPER CONTAINMENT 96703.08 69.592

.1191 27.3000 ICE CONDENSER 24404.03 15.367

.0434 27.3100 TOTAL 164713.38 t

l CALCULATCD VALUES BY READING PAGE 25 1

RDG TIME MASS TEMP VAP PRESS l

24; 19: 15:35 LOWER CONTAINMENT 43255.77 75.346

.1291 27.1180 i

UPPER CONTAINMENT 95934.84 69.586

.1184 27.0910 ICE CONDENSER 24206.74 15.431

.0442 27.0940 TOTAL 163397.36 242 19:30:35 LOWER CONTAINMENT 42897.82 75.339

.1288 26.8940 UPPER CONTAINMENT 95140.85 69.545

.1177 26.8650 ICE CONDENSER 24003.81 15.460

.0443 26.5690 TOTAL 162042.48 243 19: 45:36 LOWER CONTAINMENT 42540.61 75.261

.1285 26.6670 UPPER CONTAINMENT 94359.32 69.434

.1169 26.6390 ICE CONDENSER 23803.31 15.387

.0444 26.6410 TOTAL 160703.24 244 20: 0:37 LOWER CONTAINMENT 42166.05 75.277

.1274 26.4330 UPPER CONTAINMENT 93543.90 69.372

.1162 26.4060 ICE CONDENSER 23597.48 15.316

.0444 26.4070 TOTAL 159307.43 245 20:15:37 LOWER CONTAINMENT 41789.68 75.257

.1272 26.1972 UPPER CONTAINMENT 92721.43 69.308

.1155 26.1710 ICE CONDENSER 23390469 15.581

.0443 26.1740 TOTAL 157901.81 246 20:30:38 LOWER CONTAINMENT 41406.10 75.296

.1266 25.9590 UPPER CONTAINMENT 91878.38 69.279

.1148 25.9320 ICE CONDENSER 23174.22 15.314

.0443 25.9340 TOTAL 156458.70 247 20:45:39 LOWER CONTAINMENT 41017.63 75.277

.1259 25.7150 LAPER CONTAINMENT 91014.86 69.225

.1141 25.6860 ICE CONDENSER 22956.58 15.279

.0443 25.6890 TOTAL 154989.08 248 21: 0: 40 LOWER CONTAINMENT 40625.49 75.245

.1250 25.4680 UPPER CONTAINMENT 90150.78 69.151

.1135 25.4390 ICE CONDENSER 22733.15 15.313

.0441 25.4410 TOTAL 153509.42 249 21:15: 41 LOWER CONTAINMENT 40221.04 75.215

.1247 25.2140 UPPER CONTAINMENT 89252.91 69.147

.1128 25.1860 ICE CONDENSER 22504.92 15.321

.0447 25.1870 TOTAL 151978.86 250 21:30: 42 LOWER CONTAINMENT 39804.70 75.196

.1243 24.9530 UPPER CONTAINMENT 88333.73 69.082

.1121 24.9240 ICE CONDENSER 2'2274.43 15.259

.0444 24.9260 TOTAL 150412.85

CALCULATED VALUES BY READING PAGE RDG TIME MASS TEMP VAP PRESS 151 21: 45:42 LOWER CONTAINMENT 39375.80 75.204

.1235 24.6850 UPPER CONTAINMENT 87390.00 69.037

.1113 24.6560 ICE CONDENSER 22038.41 15.176

.0444 24.6580 TOTAL 148804.20 j

252 22: 0:42 LDWER CONTAINMENT 38943.06 75.226

.1224 24.4150 UPPER CONTAINMENT 86446.33 68.961

.1108 24.3870 l

ICE CONDENSER 21795.93 15.172

.0444 24.3870 TOTAL 147185.32 233 22: 15: 43 LOWER CONTAINMENT 38497.19 75.171

.1220 24.1340 UPPER CONTAINMENT 85447.41 68.926

.1100 24.1040 ICE CONDENSER 21546.64 15.122

.0444 24.;060 TOTAL 145491.24 254 22:30: 45 LDWER CONTAINMENT 38038.80 7 5.' 2 0 1

.1216 23.8430 UPPER CONTAINMENT 84441.21 66.886

.1093 23.8190 ICE CONDENSER 21293.44 15.076

.0444 23.8210 TOTAL 143773.45 255 22: 45:46 LOWER CONTAINMENT 37579.37 75.127

.1204 23.5580 UPPER CONTAINMENT 83427.24 68.753

.1089 23.5260 ICE CONDENSER 21036.92 14.974

.0439 23.5290 TOTAL 142043.54 256 23: 0: 46 LOWER CONTAINMENT 37099.53 75.096

.1201 23.2570 UPPER CONTAINMENT 82371.37 68.69G

.1078 23.2280 ICE CONDENSER 20771.64 14.915

.0439 23.2300 TOTAL 140242.55 257 23:15:47 LOWER CONTAINMENT 36612.62 75.076

.1195 22.9520 UPPER CONTAINMENT 81298.39 68.646

.1071 22.9240 ICE CONDENSER 20500.61 14.857

.0443 22.9250 TOTAL 138411.62 258 23:30:49 LOWER CONTAINMENT 36114.67 75.064

.1186 22.6400 UPPER CONTAINMENT 80195.29 68.603

.1065 22.6120 ICE CONDENSER 20221.10 14.830

.0445 22.6120 TOTAL 136531.06 259 23:45: 49 LOWER CONTAINMENT 35597.26 75.045

.1180 22.3160 UPPER CONTAINMENT 79052.91 68.517

.1057 22.2870 ICE CONDENSER 19930.31 14.817

.0447 22.2670 TOTAL 134580.48 260 0: 0:50 LOWER CONTAINMENT 35067.58 74.974

.1172 21.9820 LPPER CONTAINfENT 77881.02 68.390

,1048 21.9520 ICE CONDENSER 19635.49 14.761

.0443 21.9550 TOTAL 132584.08

C A L C U L_ A ~T E D VALUES BY READING PAGE iiE *7 RDG TIME MASS T5MP VAP PRESS 261 0:15:51 LOWER CDNTAINMENT 34524.99 74.930

.2163 21.6410 UPPER CONTAINMENT 76692.24 68.272

.1041 21.6130 ICE CONDENSER 19331.47 14.728

.0440 21.6140 TOTAL 130548.70 l

l262 0:30:52 LDWER CONTAINMENT 33963.66 74.905

.1153 21.2690 UPPER CONTAINMENT 75449.23 68.192

.1039 21.2610 ICE CONDENSER 19015.71 14.729

.0443 21.2620 TOTAL 128428.60 263 0: 45:52 LDWER CONTAINMENT 33387.09 74.825

.1148 20.9200 UPPER CONTAINMENT 74168.57 68.132

.1034 20.8994 ICE CDNDENSER 18696.27 14.612

.0439 20.9000 TOTAL 126251.92 264 1: 0:53 LOWER CONTAINMENT 32791.49 74t828

.1140 20.5540 UPPER CONTAINMENT 72853.69 68.031

.1030 20.5260 ICE CONDENSER 18361.30 14.605

.0448 20.5270 TOTAL 124006.48 265 1:15:53 LDWER CDNTAINMENT 32176.08 74.847

.1119 20.1700 UPPER CONTAINMENT 71497.58 67.919

.1024 20.1410 ICE CONDENSER 18016.22 14.623

.0440 20.1420 TOTAL 121689.88 266 1:30:55 LOWER CONTAINMENT 31547.53 74.703

.1120 19.7720 LAPER CONTAINMENT 70091.53 67.827

.1019 19.7430 ICE CONDENSER 17657.44 14.631

.0s49 19.7430 TOTAL 119296.50 267 1:45:56 LDWER CONTAINMENT 30889.22 74.686

.1108 19.3600 UPPER CONTAINMENT 68632.60 67.803

.1016 19.3330 ICE CONDENSER 17293.15 14.555

.0444 19.3330 TOTAL 116814.97 26@

2 0:57 LOWER CONTAINMENT 30201.90 74.584

.1097 18.3270 L.PPER CONTAINMENT 67104.92 67.636

.1016 18.8990 ICE CONDENSER 16910.39 14.398

.0445 18.9000 j

TOTAL 114217.22 269 2:15:58 LOWER CONTAINMENT 29458.52 74.490

.1081 18.4590 UPPER CONTAINMENT 65444.47 67.506

.1012 18.4290 ICE CONDENSER 16492.87 14.320

.0442 18.4310 TOTAL 111395.86 270 2:30:59 LOWER CONTAINMENT 28629.78 74.474

.1059 17.9400 UPPER CONTAINMENT 63635.70 67.242

.0997 17.9120 ICE CONDENSER 16025.28 14.359

.0440 17.9110 TOTAL 108290.76

CALCULATED VALUES BY READING PAGE JE RDG TIME MASS TEMP VAP PRESS 171 2:46: 0 LOWER CONTAINMENT 27756.53 74.337

.1'043 17.3900 UPPER CONTAINMENT 61712.79 66.965

.0990 17.3640 ICE CONDENSER 15537.72 14.248

.0436 17.3630 TOTAL 105007.04 272 3: la 1 LDWER CONTAINMENT 26879.00 74.227

.1022 16.6380 UPPER CONTAINMENT 59752.72 66.764

.0988 16.8090 ICE CONDENSER 15041.85 14.217

.0434 16.8090 TOTAL 101673.57 273 3:16: 2 LOWER CONTAINMENT 25991.64 74.*31

.0999

6.2820 UPPER CONTAINMENT 57788.85 66.632

.0980 16.2550 ICE CONDENSER 14542.93 14.248

.0435 16.2540 TOTAL 98323.42 274 3:31: A LOWER CONTAINMENT 25130.43 74.'058

.0979 15.7400 UPPER CONTAINMENT 55868.54 66.463

.0979 15.7130 ICE CONDENSER 14060.55 14.117

.0435 15.7120 TOTAL 95059.53 275 3:46: 4 LOWER CONTAINMENT 24353.80 74.159

.0965 15.2580 UPPER CONTAINMENT 54128.03 66.600

.0985 15.2310 ICE CONDENSER 13628.79 14.104

.0430 15.2300 TOTAL 92110.62 276 4: 1: 5 LOWER CONTAINMENT 23751.15 74.223

.0959 14.8640 UPPER CONTAINMENT 52763.80 66.799

.0993 14.8560 ICE CONDENSER 13293.43 14.059

.0431 14.8550 TOTAL 89808.38 277 4:16: 6 LOWER CONTAINMENT 23371.75 74.353

.0955 14.6510 L.PPER CONTAINMENT 51879.62 67.295

.1009 14,6240 ICE CONDENSER 13082.96 14.136

.0433 14.6230 TOTAL 88334.34 278 4:31: 6 LOWER CONTAINMENT 23210.51 74.536

.0970 14.5570 LPPER CONTAINMENT 51470.77 67.909

.1036 14.5290 ICE CONDENSER 12998.45 14.147

.0431 14.5290 TOTAL 87679.73 279 4:46: 8 LDWER CONTAINMENT 23175.98 74.745

.0989 14.5430 UPPER CONTAINMENT 51359.54 68.471

.1064 14.5160 ICE CONDENSER 12986.30 14.118

.0435 14.5150 TOTAL 87521.82 280 5: 1: 9 LOWER CONTAINMENT 23171.19 74.809

.1011 14.5440 LPPER CONTAINMENT 51326.11 68.746

.1083 14.5160 ICE CONDENSER 12987.25 14.079

.0437 14.5150 TOTAL 87484.55

Z NET RLJMENT C AL_ I B R ATE D DATA PAGE 1

i READING # 36 AT 17:20:19 11/24/87 l

POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 72.8;5 77.288 76.929 76.752 76.031 l

6-19 73.138 73.851 74.769 75.019 81.166 11-15 82.474 81.123 82.850 79.$34 78.535 16-29 80.131 80.378 74.353 75.731 74.765 21-25 74.415 64.113 73.088 72.328 74.064 26-38 75.071 76.350 73.720 72.642 74.275 31-35 73.593 73.657 73.899 74.339 74.246 36-48 75.232 75.285 13.050 11.819 13.447 41-45 13.043 13.636 12.486 13.786 12.671 46-50 14.099 12.967 12.402 12.373 12.483 51-52 12.313 11.135 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.6060 29.5880 29.5940 65.714

.000

.000 59-51 66.708 14.680

.000 READING # 37 AT 17:35:19 11/24/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 72.073 76.317 76.836 76.520 75.706 6-19 73.045 73.480 74.398 74.880 80.934 11-15 82.103 80.891 82.618 79.063 78.131 16-29 79.991 80.099 74.121 75.545 74.672 21-25 74.230 64.067 72.764 72.003 73.786 26-38 74.746 76.442 72.978 72.317 73.487 31-35 72.851 73.472 73.204 73.411 73.365 36-48 73.980 74.034 12.949 11.861 13.438 41-45 13.126 13.627 12.522 13.823 12.616 46-58 14.044 13.004 12.347 12.276 12.428 51-52 12.264 12.084 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.5690 29.5530 29.5590 66.191

.000

.000 59-61 66.124 14.891

.000 READING # 38 AT 17:58:19 11/24/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 71.703 76.686 76.465 76.381 75.474 1

6-18 72.860 73.248 74.167 74.695 80.702 11-15 82.149 80.612 82.525 78.552 77.667 16-29 79.852 79.821 73.936 75.406 74.579 21-25 74.044 63.928 72.439 71.725 73.508 26-39 74.561 76.164 72.515 71.947 73.162 31-35 72.387 73.147 72.833 72.809 72.763 36-48 73.377 73.339 12.982 11.888 13.419 41-45 13.158 13.563 12.463 13.759 12.510 46-56 14.026 13.127 12.333 12.258 12.414 51-52 12.296 11.112 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.5480 29.5300 29.5380 66.034

.000

.000 1

59-61 65.503 14.752

.000

I N E T R1_alvtE N T CAL I BR ATED DATA PAGE C

READING # 39 AT 18: 5:19 11/24/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 71.424 76.454 76.233 76.196 75.335 6-10 72.721 73.156 74.074 74.602 80.748 11-15 81.731 80.473 82.479 78.321 77.482 16-29 79.806 79.636 73.797 75.313 7*.44J 21-25 73.906 63.835 72.300 71.585 73.323 26-38 74.375 76.164 72.283 71.669 73.069 31-35 72.155 72.916 72.463 72.530 72.438 36-48 73.099 72.968 12.904 12.039 13.346 41-45 13.263 13.490 12.477 13.731 12.366 46-58 13.952 13.049 12.255 12.276 12.382 51-52 12.264 12.176 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.5390 29.5220 29.5280 65.394

.000

.000 59-61 64.940 14.963

.000i READING # 48 AT 18:29:18 11/24/87 j

POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 71.424 76.408 76.233 76.242 75.335 6-19 72.767 73.156 74.120 74.649 80.655 11-15 81.964 80.427 82.386 78.042 77.250 16-29 79.C67 79.636 73.843 75.406 74.486 21-25 73.352 63.928 72.300 71.585 73.369 26-30 74.375 76.164 72.190 71.622 72.745 31-35 72.062 72.823 72.463 72.530 72.392 36-48 72.960 72.876 12.986 12.718 13.474 l

41-45 13.483 13.618 12.789 13.813 12.560 46-54 14.035 12.949 12.430 12.359 12.511 3

51-52 12.392 12.258 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.5270 29.5110 29.5180 65.494

.000

.000 59-61 64.557 14.949

.000 READING # 41 AT 18:35:18 11/24/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 71.193 76.222 76.048 76.057 75.150 6-19 72.582 72.970 73.'s35 74.556 80.563 11-15 81.871 80.287 82.340 77.950 76.971 16-29 79.435 79.496 73.565 75.406 74.301 21-25 73.767 63.743 72.069 71.353 73.137 26-38 74.236 76.118 71.912 71.576 72.699 31-35 71.877 72.545 72.231 72.252 72.114 36-48 72.729 72.644 12.848 13.039 13.383 41-45 13.437 13.526 12.651 13.722 12.382 46-58 13.943 12.857 12.384 12.267 12.469 51-52 12.346 12.213 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.5170 29.5010 29.5060 65.214

.000

.000 59-61 64.126 15.098

.000

l l

I INSTRUMENT C f3 L_ I B R A T E D DATA PAGE 3

READING # 42 AT 18:59:17 11/24/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 71.100 76.222 76.001 76.057 75.057 6-18 72.582 73.016 73.888 74.556 80.516 11-15 81.824 80.380 82.247 77.950 76.925 16-29 79.435 79.543 73.565 75.499 74.301 21-25 73.813 63.743 72.115 71.353 73.184 26-38 74.190 76.350 71.866 71.530 72.652 31-35 71.831 72.453 72.185 72.159 72.021 36-48 72.682 72.505 12.959 12.645 13.40; 41-45 13.730 13.590 12.578 13.786 12.533 46-50 14.007 13.059 12.494 12.327 12.621 51-52 12.410 12.272 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 19.5130 29.4960 29.5020 65.039

.000

.000 59-61 63.734 15.094

.000 READING # 43 AT 19: 5:17 11/24/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 71.053 76.037 75.955 75.964 75.010 6-19 72.535 72.970 73.842 74.556 80.470 11-15 81.917 80.287 82.340 77.903 76.766 16-28 79.295 79.404 73.519 75.592 74.254 21-25 73.721 63.789 71.976 71.307 73.044 26-38 74.097 76.396 71.773 71.669 72.745 31-35 71.784 72.360 72.185 72.067 71.929 l

1 36-48 72.543 72.413 12.972 12.429 13.318 41-45 13.831 13.554 12.729 13.749 11.859 46-58 14.016 13.389 12.508 12.386 12.634 51-52 12.470 12.286 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.5010 29.4840 29.4920 64.359

.300

.000 59-61 63.338 15.139

.000 READING # 44 AT 19:20:17 11/24/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.822 75.851 7b.816 75.732 74.871 6-19 72.396 72.831 73.703 74.417 80.284 11-15 81.824 80.287 82.200 77.764 76.693 16-20 79.110 79.311 73.426 75.685 74.161 21-25 73.628 63.604 71.883 71.168 72.859 26-38 73.912 76.303 71.680 71.298 72.838 31-35 71.599 72.221 71.999 71.927 71.790 36-48 72.358 72.274 12.904 12.269 13.254 41-45 14.042 13.490 12.936 13.640 12.753 46-58 13.906 13.830 12.439 12.322 12.566 51-52 12.447 12.222 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4980 23.4800 29.4880 64.054

.000

.000 59-61 63.018 15.134

.000

I N E T F31JME N T C A L. I B R A T E D DATA PAGE READING # 45 AT 19:35:17 11/24/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.775 75.759 75.770 75.68G 74.871 6-18 72.350 72.831 73.657 74.463 80.238 11-15 81.731 80.148 82.572 77.672 76.554 16-28 78.970 79.265 73.380 75.870 74.115 21-25 73.582 63.604 71.837 71.075 72.859 26-34 73.865 76.257 71.587 71.298 72.606 31-35 71.599 72.221 71.953 71.881 71.743 36-48 72.358 72.227 12.940 12.397 13.337 41-45 13.666 13.526 13.202 13.768 13.708 46-58 13.943 13.17G 12.476 12.359 12.602 51-52

2.523 12.258 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4930 29.4750 29.4830 63.581

.000

.000 59-61 62.609 15.085

.000 READING # 46 AT 19:50:1,6 11/24/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.775 75.759 75.723 75.593 74.825 6-18 72.396 72.785 73.703 74.463 80.284 11-15 81.685 80.148 82.193 77.486 76.55*

16-29 78.924 79.218 73.426 76.009 74.115 21-25 73.552 63.558 71.837 71.075 72.859 26-38 73.819 76.211 71.541 71.205 71.838 31-35 71.506 72.175 71.860 71.835 71.651 36-48 72.265 72.181 13.076 13.039 13.337 41-45 13.483 13.526 12.926 13.813 13.065 46-54 13.943 12.903 12.567 12.405 12.648 51-52 12.575 12.304 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4890 29.4720 29.4780 63.617

.000

.000 59-61 62.384 15.174

.000 READING # 47 AT 20: 5:16 11/24/87 I

POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.683 75.620 75.584 75.500 74.732 6-18 72.211 72.646 73.564 74.371 80.192 11-15 82.289 80.102 82.572 77.347 76.461 16-29 78.878 79.125 73.333 75.917 74.069 21-25 73.489 63.511 71.744 71.029 72.674 26-39 73.680 76.025 71.495 71.391 72.328 31-35 71.460 71.990 71.768 71.696 71.511 36-48 72.173 72.042 13.069 13.259 13.328 41-45 13.611 13.517 12.646 13.759 12.693 46-58 13.888 12.985 12.517 12.350 12.552 51-52 12.520 12.295 PRESSURE (PSIA)

DEW POINT TEt@ERATURE 53-b5,56-54 29.4800 29.4640 29.4700 62.982

.000

.000 59-61 62.051 15.071

.000

INSTRUW1ENT C A L_ T B R A T E D DATA PAGE 5

READING # 48 AT 20:29:15 11/24/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.683 75.620 75.584 75.500 74.732 6-le 72.303 72.738 73.610 74.417 80.238 11-15 82.056 80.102 82.618 77.3.93 76.461 16-29 78.831 79.125 73.333 75.963 74.069 21-25 73.489 63.558 71.837 71.029 72.674 l

26-38 73.726 76.211 71.448 71.252 72.828 31-35 71.506 72.036 71.814 71.742 71.511 36-4e 72.219 72.042 13.161 13.259 13.419 41-45 13.973 13.563 12.779 13.800 12.669 46-59 13.929 12.939 12.604 12.483 12.6G5 51-52 12.658 12.474 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4760 29.4590 29.4660 62.407

.000

.000 59-61 61.731 15.071

.000 READING # 49 AT 20:35715 11/24/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.E30 75.527 75.399 75.407 74.639 6-19

72. ; :.1 72.646 73.517 74.371 62.iCI 11-15 81.%54 80.009 82.15*

77.254 76.368 16-29 78.765 79.033 73.241 75.638 74.022 21-25 73.337 63.465 71.698 70.869 72.56i 26-38 73.587 76.257 71.309 71.459 72.316 31-35 71.321 71.851 71.721 71.603 71.372 36-40 72.080 71.857 13.032 13.222 13.337 41-45 13.895 13.480 12.880 13.722 12.973 46-56 13.851 12.719 12.476 12.359 12.556 51-52 12.575 12.304 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4690 29.4530 29.4570 62.645

.000

.000 59-61 61.425 15.139

.000 READING # 58 AT 20:50:15 11/24/87 i

POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.451 75.434 75.352 75.315 74.546 6-18 72.164 72.553 73.425 74.324 80.052 11-15 8*.406 80.005 82.432 77.208 76.275 16-28 78.692 79.033 73.194 75.499 73.976 21-25 73.397 63.465 71.652 70.797 72.'581 26-39 73.541 75.979 71.263 71.020 72.467 31-35 71.274 71.851 7;.675 71.510 71.372 36-48 72.034 71.857 13.004 13.057 13.309 41-45 13.776 13.499 12.899 13.694 13.221 46-50 13.870 13.059 12.540 12.418 12.712 51-52 12.639 12.410 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4670 29.4490 29.4550 62.317

.000

.000 i;

59-61 61.297 15.125

.002 1

I N E T RLAME N T C3 AL I B R ATED DATA PAGE C

READING # 51 AT 21: 5:14 11/24/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.451 75.358 75.306 75.315 74.546 6-10 72.16*

72.553 73.425 74.324 80.052 11-15 81.685 79.962 62.i38 7 6. 9,7 6 76.322 16-28 76.738 78.986 73.194 75.592 74.022 21-25 73.397 63.373 71.652 70.797 72.581 26-39 73.448 76.418 71.263 71.067 72.235 31-35 71.321 71.805 71.629 71.510 71.326 36-49 71.987 71.811 12.848 13.818 13.333 41-45 14.716 13.526 13.018 13.768 13.476 46-50 13.897 13.040 12.521 12.451 12.648 51-52 12.575 12.442 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4620 29.4440 29.4500 62.028

. 230

. 000 l 59-61 60.786

S.116

.000' READING # 52 AT 21:29:14 11/24/87

)

POINTS:

TEMPERATURE (FAHRENHE1T) 1-5 70.431 75.388 75.352 75.315 74.500 6-18 72.1;8 72.553 73.425 74.324 80.006 11-15 81.6G5 80.009 82.340 76.883 76.275 16-29 78.646 78.940 73.194 75.592 74.022 21-25 73.350 63.373 71.653 70.750 72.535 26-38 73.448 75.932 71.217 71.020 72.374 31-35 71.274 71.758 71.536 74.310 71.326 36-48 71.941 71.764 12.89*

14.034 13.383 41-45 14.853 13.526 13.264 13.813 13.616 46-58 13.897 12.949 12.067 12.496 12.694 51-52 12.667 12.442 PRESSURE (PSIA)

DEW POINr TEMPERATURE 53-55,56-58 29.4590 29.4*00 29.4470 61.646

.000

.000 59-61 60.548 15.233

.000 READING # 53 AT 21:35:13 11/24/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.404 75.295 75.306 15.222 74.454 6-18 72.072 72.553 73.378 74.324 80.006 11-15 81.871 80.009 82.061 76.930 76.136 16-29 78.692 78.986 73.194 75.543 74.022 21-25 73.350 63.419 71.559 70.750 72.488 26-38 73.402 75.747 71.217 71.067 72.142 l

31-35 71.135 71.666 71.536 71.417 71.326 36-40 71.941 71.764 12.995 13.461 13.346 i

41-45 14.450 13.490 12.890 13.823 13.212 46-58 13.861 13.233 12.576 12.501 12.749 51-52 12.676 12.492 PRESSURE (PSIA)

DEW POINT TEt@ERATURE 53-55,56-58 29.4560 29.4360 29.4430 61.587

.000

.000 59-61 60.211 15.130

.000 i

e I N ST RLJME N T CALIBRATED DATA PAGE 7

READING # 54 AT 21:50:13 11/24/87 POINTS:

TEMPERATURE (FAHREMEIT) 1-5 70.312 75.249 75.213 75.222 74.407 6-18 72.025 72.507 73.286 74.232 79.960 11-15 81.546 79.823 81.875 76.883 75.997 16-28 78.506 78.847 73.055 75.685 73.929 21-25 73.258 63.280 /

71.559 70.657 72.396 26-39 73.309 75.423 7 1'. 1 2 4

71.067 72.003 31-35 71.135 71.620

'71.490 71.325 71.

4.

36-48 71.848 71.672 15.940

'13.543 13.291 41-45 13.804 13.435

~ 12.743

' 13.813 12.862 46-58 13.806 13.453 12.$21 12.496 12.G34 51-52 12.667 12.483 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4510 29.4320 29.4390 61.457

.000

.000 59-61 59.859 13.354

.020 READING # 55 AT 22: 5:13 11/24/87

/

POINTS:

TEMPERATURE (FAHNENHEIT) 1-5 70.312 75.202 75.213 75.129 74.407 6-19 72.025 72.460 73.286 74.278 79.960 11-15 81.731 79.916 82.128 77.069 75.951 16-29 78.506 78.801 73.102 75.638 73.929 21-25 73.238 63.373 71.513 70.657 72.349, 26-30 73.309 75.562 71.078 71.113 72.320 31-35 71.181 71.666 71.536 71.37; 71.161 36-48 71.895 71.672 12.995 13.548

3.346 41-45 13.900 13.535-13.119 13.818 12.845 i

46-58 13.856 13.279 12.576 1.i. 5 0 1 12.749 l

51-52 12.722 12.538 PRESCURE (PSIA)

Dent POINT TEMPERATURE 53-55,56-58 29.4480 29.4280 29.4340 60.786

.000 000 59-61 53.675 15.422

.000 READING # 56 AT 22:20:1,3 11/24/87 POINTS:

1EMPERATUW. (FAHRENHEIT) 1-5 70.312 75.156 75.121 75.063 74.314 6-19 71.979 72.414 73.286 74.232 80.192 11-15 81.499 79.823 81.783 76.837 75.904 16-29 78.506 78.801 73.055 75.499 73.929

+

21-25 73.212 63.326 71.533 70.611 72.396 26-38 73.170 75.608 71.078 71.020 72.003 31-35 71.135 71.573 71.442 71.371 71.141 36-48 71.802 71.625 13.069 J3.076 13.328 41-45 14.436 13.471 13.606 13,850 13.056 46-5e 13.842 13.077 12.558 12.533 12.776 51-52 12.703 12.524 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4450 29.4250 29.4310 60.399

.000

.000 59-61 59.301 15.287

.000

INBTRUMENT C 9 1,_ I B R A T E D DATA A AEBE h

y READING # 57 AT 22:35:13 11/24/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.265 75.110 75.121 75.036 74.314 6-18 71.979 72.367 73.239 74.232 79.913 11-15 81.592 79 823 81.922 76.883 75.858 16-28 78.414 78,,30a 73.055 75.638 73.976 21-25 73.212 63.'234 71.466 70.518 72.303 26-39 73.170 75.469 70.985 70.928 72.003 31-35 71.042 71.527 71.443 71.325 71.035 36-48 71.776 71.625 13.078 12.947 13.383 41d45 14.441; 13.526 13.615 13.813 12.836 46 54 13.851 12.949 12.567 12.496 12.831 51-d2 12.713 12.529 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4410 29.4300 29.4270 60.364

.000

.200 59-61 59.153 15.233

.000 READING # 58 AT 22:50:12,11/24/87 POINTS:

TEMPERATURE (FAHRENHEIT) i 1-5 70.2:9 75.017 74.935 75.036 74.268 6-19 71.979 72.367 73.147 74.139 79.913 11-15 81.638 79.869 82.061 76.837 75.7&A 16-29 78.367 78.755 73.003 75.592 73.929 21-25 73.li3 63.234 71.374 70.518 72.256 26-38 73.124 75.469 70.892 70.835 72.003 31-35 70.950 71.481 71.258 71.232 71,048 36-48 71.709 71.533 13.014 12.837 13.273 41-45 14.152 13.508 13.780 13.841 12.638 46-58 13.787 12.751 12.553 12.524 14.818 3

51-52 12.694 12.515 PRES 9URE (PSIA)

DEW POINT TEPE)ERATURE 53-55,56-54 29.4350 29.4160 29.4210 60.341

.000

.000 59-61 58.660 15.350

.000 READING # 59 AT 23: 5:12 11/24/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.265 75.063 74.981 74.990 74.266 6-19 71.979 72.414 73.239 74.185 79.867 11-15 81.313 79.823 82.340 76.837 75.765s 16-29 78.367 78.708 73.055 75.638 73.929 21-25 73.212 63.234 71.420 70.565 72.256 26-38 73.124 75.515 70.985 70.835 71.910 31-35 71.089 71.527 71.351 71.325 71.095 36-44 71.756 71.579 13.261 12.856 13.337 41-45 13.987 13.526 13.431 13.859 13.065 46-54 13.851 12.719 12.613 12.583 12.923 51-52 12.804 12.621 PRESSURE (PSIA)

DEW POINT TEP5)ERATURE 53-55,56-58 29.4330 29.4140 29.4190 59.905

.000

.000 59-61 58.586 15.404

.000

) f, "N" 4 e f 'i 4

\\

4 l

u t 1

I N EIUdu E* N T ' C A L. I B R A ~T E D D A'T"A PAGE 9

i

\\

\\s/

READING # 60 AT 23:d0:12 11/24/87 l

POINTG h

TEMoERATURE (FAHRENHEIT) 1-5 '

70.173 75.017 74.981 74.990 74.222

)

5 ?

6-10 71.932 72.367 73.193 74.185 80.099 11-15 82.453 79.823 81.968 77.162 75.763 16-29 78.321 78.755 73.055 75.592 73.929 21-25 73.119 63.234 71.420 70.518 72.303 26 -30 73.077 75.284 70.892 70.835 71.957 31-35 70.996 71.573 71.258 71.232 71.002 36-40 71.709 71.539 13.243 12.791 13.318 41-45 13.785 13.554 13.183 13.836 13.368 46-50 13.879 12.838 12.641 12.565 12.951 51-52 12.832 12'602 PRESSUP.E (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4296 29.4090 29.4150 59.432

.000

.000 59-61 58.393 15.265

.000 READTNG # 61 AT 23:35:12 11/24/87

~

POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 7t.a. 1 7 3

/4.924 74.889 74.944 74.129 6-18 71. 8 5 i 73.321 73.147 74.139 80.099 11-15 di 453 79.730 82.340 77.069 75.672 16-20 78.a?4 78.523 73.009 75.685 73.883 21-25 73.0/3 63.141 71.327 70.426 72.256 26-38 72.985 75.376 70.846 70.789 71.818 31-35 70.996 71.481 71.212 71.139 7'.002 36-48 71.6G3 71.486 13.225 12.635 1 3.~ 2 5 4 41-45 13.7d1 13.400 13.119 13.777 13.166 46-50 1 3. 8 J. 5 12.512 12.622 12.547 12.887 51-52 12.768 12,492 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4250 29.4040 29.4110 59.095

.000

.000 59-61 58.041 15.364

.000 READING # 62 AT 23:50:12 11/24/87 POINTS:

TEMPERATURE (FAHRENHEIT) i-5 70.219 74.924 74.935 74.990 74.175 6-10 71.932 72.367 73.147 74.185 80.099 11-15 81.453 79.777 81.968 76.883 75.672 16-29 78.182 78.569 73.009 75.638 73.883 21-25 73.119 63.141 71.327 70.426 72.256 26-30 73.031

'75.376 70.892 70.928 71.818

'31-35 70.996 71.527 71.212 71.186 70.863 36-40 71.617 71.440 13.170 12.672 13.337 l

41-45 13.758 13.526 13.202 13.813 12.973 46-50 13.851 13.132 12.613 12.583 12.923 51-52 12'.804 12.575 PRESSURE (f61A)

DEW POINT TEMPERATURE 53-55,56-58 29.4250 29.40h4 29.4100 59.243

.000

.000 59-61 57.722 15.337

.000 l

INSTRUMENT CALIBRATED DATA PAGE 1G l

READING # 63 AT 0: 5:12 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.126 74.924 74.842 74.897 74.129 6-10 71.840 72.275 73.054 74.139 80.006 11-15 81.021 79.777 82.386 76.605 75.672 16-20 78.135 78.523 72.916 75.453 73.837 21-25 73.073 63.095 71.235 70.379 72.164 26-30 72.892 75.191 70.800 70.696 71.910 31-35 70.857 71.342 71.165 71.139 70.863 36-40 71.524 71.394 13.096 12.782 13.355 41-^5 13.822 13.499 13.128 13.786 12.900 46-50 13.824 13.059 12.586 12.556 12.896 51-52 12.823 12.685 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4220 29.4020 29.4070 58.717

.000

.000 59-61 57.699 15.580

.002 READING # 64 AT 0:20:11 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.126 74.832 74.842 74.851 74.175 6-10 71.932 72.367 73.100 74 139 80.145 11-15 81.267 79.823 82.154 77.069 75.811 16-20 78.'35 78.476 72.963 75.545 73.883 2i-25 73.073 63.095 71.327 70.379 72.210 26-30 72.985 75.376 70.846 70.928 71.771 31-35 70.950 71,342 71.119 71.139 70.909 36-40 71.617 71.440 13.271 13.323 13.392 41-45 13.946 13.535 13.303 13.818 12.937 46-50 13.610 12.958 12.666 12.593 13.024 51-52 12.859 12.721 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-59 29.4190 29.3980 29.4030 56.608

.000

.000 59-61 57.335 15.562

.000 READING # 65 AT 0:35:11 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.126 74.878 74.796 74.851 74.129 6-10 71.886 72.275 73.100 74.093 80.006 11-15 81.313 79.777 82.061 76.976 75.765 16-20 78.135 78.476 72.963 75.592 73.929 21-25 73.073 63.141 71.281 70.426 72.164 26-30 72.938 75.376 70.800 70.835 71.910 31-35 70.903 71.388 71.073 71.139 70.909 36-40 71.570 71.440 13.243 13.708 13.410 41-45 13.918 13.508 13.137 13.836 12.863 46-50 13.787 12.930 12.686 12.657 13.042 51-52 12.878 12.786 l

PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4140 29.3940 29.4010 58.577

.000

.000 59-61 57.096 15.445

.000

INSTRUMENT C A L_ I B R A T E D DATA PAGE 11 READING # 66 AT 0:50:11 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.034 74.739 74.750 74.804 74.036 6-10 71.793 72.228 73.054 74.093 80.099 11-15 81.360 79.637 81.922 77.Q23 75.672 16-20 78.042 78.245 72.916 75.545 73.837 21-25 73.027 63.049 71.235 70.286 72.117 26-30 72.846 75.330 70.753 70.742 71.679 31-35 70.811 71.249 71.026 71.000 70.817 36-40 71.524 71.347 13.197 13.066 13.273 41-45 14.056 13.462 13.000 13.795 12.772 46-50 13.787 12.884 12.686 12.565 12.951 51-52 12.832 12.694 PRESSURE (PSIA)

DEW POINT TEMPERATURE l

53-55,56-5C 29.4120 29.3910 29.3970 58.005

.000

.000 i

59-61 56.867 15.571

.000 READING # 67 AT 1: 5:11 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.126 74.785 74.750 74.804 74.082 6-10 71.666 72.275 73.054 74.093 79.867 11-15 81.592 79.730 82.479 77.115 75.672 16-20 77.950 78.430 72.916 75.638 73.929 21-25 73.027 63.049 71.281 70.333 72.164 26-30 72.892 75.284 70.800 71.067 71.771 31-35 70.857 71.296 71.119 71.093 70.817 36-40 71.524 71.394 13.399 12.856 13.291 41-45 14.033 13.526 13.064 13.768 12^152 46-50 13.806 13.361 12.751 12.629 13.015 51-52 12.850 12.712 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4100 29.3900 29.3960 57.969

.000

.000 59-61 56.660 15.562

.000 READING # 68 AT 1:20:38 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.080 74.739 74.703 74.712 73.990 6-10 71.840 72.228 73.054 74.093 79.774 11-15 81.360 79.591 82.061 77.115 75.672 16-20 77.950 78.337 72.870 75.592 73.883 21-25 73.027 63.003 71.235 70.286 72.117 26-30 72.799 75.191 70.661 70.881 71.771 31-35 70.811 71.249 71.026 71.046 70.770 36-40 71.478 71.301 13.353 12.764 13.245 41-45 14.349 13.480 13.248 13.768 12.927 46-50 13.760 13.866 12.659 12.583 13.015 51-52 12.850 12.666 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4100 29.3880 29.3940 57.695

.000

.000 59-61 56.435 15.431

.000

I N E T R LJ tvlE N T C A L_ I B R A T EEE D DATA PAGE 16 READING # 69 AT 1:35:38 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.034 74.693 74.703 74.712 73.990 6-10 71.840 72.182 73.007 74.046 79.867 11-15 81.685 79.684 82.061 77.0.23 75.626 16-20 77.950 78.337 72.916 75.638 73.837 21-25 72.980 63.003 71.235 70.240 72.117 26-30 72.799 75.191 70.707 70.881 71.679 31-35 70.764 71.296 71.026 71.046 70.817 36-48 71.478 71.347 13.399 12.672 13.245 41-45 14.033 13.480 13.431 13.813 13.937 46-50 13.714 13.224 12.705 12.629 13.015 f

51-52 12.896 12.666 1

PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4060 29.3840 29.3900 57.519

.000

.000 59-61 56.174 15.490

.000 READING # 70 AT 1:50:38 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.034 74.693 74.657 74.665 73.990 6-19 7 1.' 8 8 6 72.275 73.054 74.093 79.867 11-15 81.406 79.777 82.061 77.115 75.719 16-20 77.903 78.384 72.916 75.685 73.837 21-25 73.027 63.003 71.188 70.240 72.025 26-30 72.753 75.330 70.661 70.742 71.818 31-35 70.764 71.203 71.026 71.046 70.724 36-48 71.478 71.301 13.353 12.718 13.291 41-45 13.758 13.480 13.385 13.813 13.432 46-56 13.714 12.994 12.705 12.629 12.969 51-52 12.896 12.666 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4020 29.3800 29.3870 57.119

.000

.000 59-61 55.872 15.395

.000 READING # 71 AT 2: 5:38 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.000 74.693 74.703 74.712 74.036 6-10 71.886 72.275 73.054 74.093 79.960 11-15 81.406 79.730 82.293 77.208 75.672 16-29 77.903 78.337 72.916 75.870 73.883 21-25 73.027 63.095 71.235 70.286 72.071 26-30 72.799 75.376 70.707 70.928 71.725 31-35 70.811 71.249 71.026 71.046 70.770 36-40 71.524 71.301 13.381 12.700 13.318 41-45 13.827 13.508 13.046 13.882 13.047 46-5e 13.787 13.205 12.732 12.657 13.042 51-52 12.969 12.740 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.4020 29.3810 29.3870 57.344

.000

.000 59-61 55.733 15.562

.000

INSTRUMENT C A L_ I B R A T E D DATA PAGE 13 READING # 72 AT 2:20:39 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.987 74.693 74.611 74.573 73.943 6-10 71.747 72.182 72.915 74.046 79.821 11-15 81.313 79.684 82.108 77.2.08 75.579 16-20 77.857 78.384 72.870 75.870 73.790 21-25 72.934 62.910 71.142 70.194 72.023 26-30 72.707 75.052 70.661 70.603 71.679 31-35 70.811 71.249 70.980 71.000 70.770 l

36-40 71.385 71.255 13.188 13.057 13.309 41-45 14.005 13.499 12.858 13.786 12.767 l

46-50 13.732 12.880 12.728 12.652 12.992 51-52 12.868 12.735 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3990 29.3780 29.3840 56.903

.000

.000 59-61 55.517 15.456

.000 READING # 73 AT 2:36:28 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.987 74.646 74.611 74.573 73.943 6-10 71.747 72.136 72.961 74.046 79.774 11-15 81.546 79.637 81.875 77.115 75.626 16-20 77.857 78.337 72.870 75.870 73.730 21-25 72.934 62.956 71.142 70.240 72.025 26-30 72.707 75.469 70.614 70.928

'1. 725 31-35 70.764 71.249 70.980 70.904 10,724 36-40 71.431 71.255 13.280 13.562 13.309 41-45 13.868 13.499 12.761 13.740 13.083 46-50 13.732 12.692 12.723 12.648 12.942 51-52 12.914 12.685 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3960 29.3770 29.3820 56.822

.000

.000 59-61 55.301 15.471

.000 l

READING # 74 AT 2:51:28 11/25/87 i

POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 70.034 74.693 74.657 74.665 73.943 6-10 71.793 72.182 73.007 74.046 79.728 11-15 81.267 73.684 81.922 77.069 75.672 16-20 77.810 78.291 72.916 75.917 73.837 21-25 72.980 62.910 71.142 70.194 72.025 26-30 72.753 75.098 70.661 70.835 71.632 31-35 70.811 71.203 71.026 71.000 70.770 36-40 71.478 71.255 13.032 13.864 13.291 41-45 13.804 13.480 12.880 13.768 13.203 46-50 13.714 12.949 12.705 12.675 13.015 51-52 12.942 12.758 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3950 29.3730 29.3780 56.624

.000

.000 59-61 55.058 15.548

.000

I N S T RLJME N T C A1._ I B R A T E D DATA PAGE id READING # 75 AT 3: 6:28 11/25/87 POINTS:

TEppERATURE (FAHRENHEIT) 1-5 69.987 74.600 74.611 74.573 73.897 6-18 71.793 72.136 72.915 74.000 79.913 11-15 81.360 79.730 81.875 77.0,69 75.579 16-29 77.764 78.245 72.824 75.917 73.790 21-25 72.934 62.910 71.142 70.147 71.978 26-39 72.660 75.098 70.661 70.696 71.493 31-35 70.718 71.157 70.934 70.954 70.678 36-48 71.385 71.209 13.225 14.557 13.392 41-45 14.679 13.490 13.119 13.777 13.579 46-58 13.723 12.958 12.668 12.639 12.978 51-52 12.905 12.721 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3920 29.3710 29.3770 56.201

.000

.000l 59-61 54.860 15.499

.000 READING # 76 AT 3:21:28 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.987 74.646 74.611 74.619 73.943 6-19 71.793 72.182 73.007 74.093 80.006 11-15 81.546 79.730 82.154 77.162 75.G26 16-29 77.810 78.291 72.916 75.963 73.837 21-25 72.980 62.956 71.142 70.240 72.025 26-38 72.707 75.330 70.614 70.696 71.725 31-35 70.718 71.203 70.934 71.000 70.724 36-48 71.385 71.255 13.289 14.392 13.410 41-45 14.926 13.554 13.137 13.83G 13.827 46-58 13.787 12.976 12.778 12.749 13.042 51-52 12.969 12.786 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3970 29.3750 29.3790 56.115

.000

.000 59-61 54.689 15.530

.000 READING # 77 AT 3:36:29 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.895 74.554 74.518 74.480 73.850 6-19 71.747 72.182 72.915 74.000 79.774 11-15 81.406 79.637 82.479 77.023 75.487 16-20 77.764 78.245 72.824 75.917 73.790 21-25 72.934 62.864 71.096 70.147 72.025 26-30 72.614 75.237 70.614 70.789 71.771 31-35 70.764 71.110 70.841 70.907 70.631 36-40 71.339 71.162 13.362 13.598 13.346 41-45 14.312 13.490 12.798 13.777 13.120 46-5e 13.677 13.233 12.668 12.639 12.978 51-52 12.951 12.813 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3890 29.3680 29.3740 55.782

.000

.000 59-61 54.464 15.422

.000l

I N S T R UfwlE N T C A L._ I B R A T E D DATA PAGE 15 READING # 78 AT 3:51:29 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.987 74.554 74.518 74.526 73.850 6-19 71.747 72.182 72.961 74.000 79.960 11-15 81.406 79.637 82.154 77.Q69 75.579 16-28 77.718 78.152 72.824 75.963 73.790 21-25 72.888 62.910 71.142 70.194 71.978 26-39 72.660 75.052 70.614 70.835 71.725 31-35 70.718 71.157 70.887 70.954 70.678 36-49 71.385 71.162 13.161 13.809 13.373 41-45 13.886 13.517 12.963 13.850 13.010 46-50 13.659 13.444 12.696 12.712 13.006 51-52 12.978 12.795 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3890 29.3670 29.3730 55.827

.000

.000 59-61 54.302 15.494

.000 READING # 79 A' 4: 6:29 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.987 74.600 74.564 74.526 73.897 6-19 71.793 72.228 73.007 74.046 79.960 11-15 81.592 79.684 32.340 77.115 75.626 16-29 77.718 78.337 72.824 75.963 73.790 21-25 72.934 62.864 71.142 70.147 72.025 26-38 72.660 75.006 70.614 71.113 71.725 31-35 70.718 71.157 70.980 70.954 70.631 36-48 71.431 71.209 13.454 13.644 13.392 41-45 13.813 13,535 13.303 13.823 12.937 46-58 13.677 13.233 12.714 12.684 13.070 51-52 12.951 12.813 PRESSURE (PSIA)

DEW POINT TEPPERATURE 53-55,56-58 29.3860 29.3640 29.3700 55.481

.000

.000 59-61 54.090 15.562

.000 READING # 80 AT 4:21:29 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.941 74.507 74.518 74.480 73.850 6-18 71.747 72.136 72.915 74.046 79.913 11-15 81.360 79.637 82.200 77.069 75.626 16-29 77.718 78.198 72.824 76.009 73.790 21-25 72.888 62.817 71.049 70.101 71.978 26-30 72.568 75.191 70.568 70.742 71.864 31-35 70.672 71.110 70.795 70.861 70.585 36-48 71.339 71.162 13.188 13.103 13.401 41-45 14.418 13.499 13.633 13.786 13.042 46-58 13.641 13.017 12.682 12.744 12.992 51-52 12.914 12.781 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3820 29.3590 29.3660 55.238

.000

.000 59-61 53.906 15.724

.000

I NST RLJMENT C AL_.I B R A T E D DATA PAGE 1(

READING # 81 AT 4:36:29 11/25/87 POINTS:

TEPPERATURE (FAHRENHEIT) 1-5 69.941 74.554 74.472 74.526 73.850 6-18

/1.701 72.089 72.961 74.046 79.867 11-15 81.592 79.637 81.783 77.115 75.348 16-29 77.671 78.198 72.824 76.609 73.744 4

21-25 72.934 62.864 71.142 70.147 71.932 26-38 72.568 75.191 70.568 70.789 71.632 31-35 70.672 71.110 70.841 70.861 70.585 36-49 71.385 71.162 13.482 12.984 13.419 41-45 14.482 13.517 13.743 13.804 12.827 46-58 13.659 12.939 12.696 12.712 13.006 51-52 12.978 12.795 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3820 29.3580 29.3640 55.049

.000

.000 59-61 53.735 15.661

.000 READING # 82 AT 4:51:29 11/25/87 POINTS:

TEMPERATURE (FAHRENFEIT) 1-5 69.941 74.554 74.518 74.526 73.804 6-18 71.747 72.182 72.915 74.046 79.821 11-15 81.081 79.591 81.968 77.069 75.579 16-29 77.718 78.198 72.778 76.102 73.744 21-25 72.934

'62.817 71.049 70.101 71.932 26-39 72.568 75.237 70.522 70.789 71.725 31-35 70.625 71.064 70.934 70.907 70.678

{

36-48 71.339 71.162 13.261 12.947 13.428 1

41-45 14.166 13.480 13.798 13.809 12.698

{

'46-58 13.664 12.719 12.705 12.721 13.061 51-52 12.987 12.758 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3810 29.3600 29.3640 55.107

.000

.000 59-61 53.487 15.656

.000 READING # 83 AT 5: 6:30 11/25/87 POINTS:

TEMPERATURE (FAHRENFEIT) 1-5 69.941 74.507 74.518 74.573 73.804 6-19 71.793 72.182 72.915 74.046 79.867 11-15 81.267 79.730 82.386 76.976 75.440 16-29 77.625 78.059 72.824 76.102 73.744 21-25 72.888 62.864 71.096 70.147 72.025 26-38 72.614 75.191 70.568 70.650 71.771 31-35 70.672 71.064 70.841 70.954 70.631 36-48 71.385 71.209 13.528 12.892 13.419 41-45 13.927 13.517 13.468 13.800 13.056 46-58 13.705 12.664 12.741 12.758 13.052 51-52 13.024 12.795 PRESSURE (PSIA)

DEW POINT TEPRERATURE 53-55,56-58 29.3790 29.3580 29.3620 54.536

.000

.000 59-61 53.303 15.669

.000 l

I N ST RU M EE N T C A L_ I B R A T E D DATA PAGE 17 READING # 84 AT 5:21:30 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.895 74.554 74.518 74.480 73.804 6-18 71.793 72.136 72.961 74.046 79.821 11-15 81.546 79.637 81.875 77.023 75.533 16-29 77.625 78.245 72.824 76.241 73.837 21-25 72.888 62.864 71.096 70.147 71.978 26-39 72.614 74.959 70.522 70.650 71.E79 31-35 70.672 70.971 70.887 70.861 70.631 36-48 71.292 71.209 13.491 12.718 13.428 41-45 13.758 13.526 13.294 13.768 13 340 46-58 13.668 12.765 12.705 12.721 13.107 51-52 13.033 12.712 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3760 29.3530 29.3600 54.617

.000

.000 59-61 53.069 15.512

.000 1

l READING # B5 AT 5:36:31 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.895 74.507 74.425 74.480 73.758 6-19 71.701 72.136 72.868 74.000 80.006 i

11-15 81.313 79.591 82.386 77.023 75.533 16-29 77.625 78.059 72.778 76.288 73.744 21-25 72.842 62.771 71.049 70.101 71.886 26-38 72.521 74.959 70.475 70.557 71.540 31-35 70.625 70.971 70.841 70.861 70.585 36-48 71.292 71.116 13.427 12.608 13.364 41-45 13.694 13.462 13.183 13.704 13.139 46-58 13.696 12.843 12.691 12.799 13.134 51-52 13.061 12.698 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3750 29.3510 29.3570 54.320

.000

.000 59-61 52.938 15.647

.000 READING # 86 AT 5 51:31 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.848 74.507 74.425 74.480 73.804 6-10 71.747 72.136 72.868 74.046 80.099 11-15 81.128 79.637 81.968 76.976 75.533 16-29 77.671 78.152 72.824 76.427 73.790 21-25 72.934 62.817 71.049 70.101 71.978 26-30 72.521 75.191 70.522 70.650 71.586 31-35 70.625 71.018 70.841 70.861 70.585 36-40 71.339 71.162 13.518 12.745 13.410 41-45 13.694 13.462 13.183 13.795 12.955 46-5e 13.742 13.068 12.778 12.794 13.180 51-52 13.107 12.786 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3750 29.3520 29.3580 54.257

.000

.000 59-61 52.767 15.773

.000

I N ST RLJME N T C A L_ I B R A T E D DATA P A G EE 1

READING # 87 AT 6: 6:31 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.895 74.461 74.379 74.434 73.711 6-18 71.701 72.136 72.868 74.000 79.867 11-15 81.035 79.591 82.108 77.023 75.301 16-29 77.578 78.059 72.778 76.334 73.744 21-25 72.888 62.771 71.049 70.054 71.932 26-38 72.521 74.959 70.522 70.881 71.540 31-35 70.672 70.971 70.841 70.861 70.539 36-48 71.339 71.162 13.298 12.846 13.373 41-45 13.744 13.471 13.147 13.754 12.872 46-58 13.659 12.939 12.696 12.804 13.143 51-52 13.024 12.841 PRESSURE (PSIA)

DEW POINT TEl@ERATURE 53-55,56-58 29.3710 29.3500 29.3550 53.960

.000

.000' 59-61 52.547 15.751

.000 READING # 86 AT 6:21:31 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.895 74.461 74.425 74.341 73.711 6-19 71.701 72.182 72.868 74.000 79.867 11-15 81.081 79.591 82.340 77.023 75.394 16-29 77.578 78.152 72.778 76.381 73.744 21-25 72.842 62.771 71.003 70.054 7:.932 26-38 72.521 75.237 70.522 70.789 71.771 31-35 70.672 70.971 70.841 70.861 70.585 36-48 71.339 71.162 13.298 13.076 13.373 41-45 13.836 13.471 13.284 13.754 12.827 46-50 13.613 12.802 12.696 12.758 13.189 51-52 13.024 12.886 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3710 29.3480 29.3540 53.834

.000

.000 59-61 52.389 15.715

.000,

READING # 89 AT 6:36:32 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.848 74.461 74.379 74.434 73.758 6-10 71.701 72.089 72.868 74.046 79.913 11-15 81.035 79.637 82.479 76.976 75.394 16-29 77.578 78.013 72.778 76.473 73.744 21-25 72.888 62.817 71.003 70.054 71.932 26-30 72.475 75.006 70.475 70.789 71.679 31-35 70.579 70.971 70.795 70.815 70.585 36-4e 71.292 71.162 13.326 13.516 13.401 41-45 13.822 13.499 13.128 13.786 12.762 46-50 13.687 12.783 12.723 12.785 13.217 51-52 13.006 12.868 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3680 29.3450 29.3510 53.704

.000

.000 59-61 52.210 15.706

.000

INSTRUMENT CALIBRATED DATA PAGE 19 1

l READING # 98 AT 6:51:32 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.895 74.415 74.379 74.294 73.758 6-18

71. 74*,-

72.182 72.915 74.000 80.00G 11-15 81.035 79.637 82.200 76.976 75.440 16-29 77.578 78.105 72.824 7 6. 3'8 1 73.744 21-25 72.888 62.771 71.049 70.054 71.932 26-38 72.521 75.191 70.522 70.789 71.540 31-35 70.672 70.971 70.841 70.861 70.631 36-40 71.339 71.209 13.390 12.984 13.373 41-45 13.927 13.517 13.009 13.754 12.735 46-50 13.659 12.893 12.741 12.804 13.281 51-52 13.070 12.886 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3680 29.3450 29.3500 53.546

.000

.000 59-61 52.057 15.733

.000 READING # 91 AT 7: 6:32 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.802 74.461 74.332 74.434 73.758 6-10 71.701 72.089 72.822 73.954 79.867 11-15 81.081 79.591 82.061 77.023 75.394 16-29 77.625 78.059 72.778 76.520 73.697 21-25 72.842 62.679 71.003 70.008 71.932 26-30 72.429 75.145 70.475 70.742 71.493 31-35 70.625 70.925 70.748 70.815 70.539 36-48 71.292 71.070 13.372 12.736 13.218 41-45 14.051 13.453 13.041 13.694 12.079 46-58 13.641 13.242 12.728 12.790 13.217 51-52 13.006 12.827 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3660 29.3430 29.3480 53.433

.000

.000 59-61 51.894 15.701

.000 READING # 92 AT 7:21:32 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.895 74.461 74.332 74.387 73.711 6-10 71.747 72.136 72.868 74.000 79.913 11-15 81.221 79.591 82.293 76.976 75.487 16-29 77.532 78.105 72.778 76.427 73.744 i

21-25 72.842 62.725 70.957 70.054 71.932 I

26-30 72.475 75.284 70.475 70.742 71.864 l

31-35 70.625 70.971 70.748 70.815 70.539 l

36-48 71.292 71.116 13.298 12.617 13.190 41-45 14.294 13.425 13.147 13.708 13.469 46-5e 13.613 13.765 12.696 12.804 13.189 51-52 13.024 12.841 1

PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3650 29.3420 29.3470 53.357

.000

.000 59-61 51.696 15.701

.000

I N S T R ufviE N T CALIBRATED DATA PAGE iEM READING # 93 AT 7:36:33 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.848 74.415 74.286 74.341 73.711 6-10 71.701 72.136 72.822 74,000 80.099 11-15 81.406 79.637 82.200 76.9.76 75.394 16-29 77.578 78.152 72.778 76.427 73.744 21-25 72.842 62.771 71.003 70.008 71.886 26-39 72.382 75.052 70.429 70.603 71.679 31-35 70.579 70.879 70.748 70.815 70.539 36-49 71.246 71.070 13.188 12.690 13.218 41-45 13.822 13.407 13.358 13.694 13.772 46-58 13.549 13.059 12.723 12.785 13.125 51-52 13.097 12.822 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3620 29.3400 29.3460 53.033

.000

.000 59-61 51.476 15.638

.000 READING # 94 AT 7:51:33 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.848 74.461 74.332 74.434 73.711 6-19 71.701 72.136 72.822 74.046 80.006 11-15 80.988 79.591 82.200 76.976 75.533 16-29 77.578 78.059 72.824 76.520 73.744 21-25 72.842 62.725 70.957 70.008 71.932 26-38 72.429 75.006 70.429 70.928 71.540 31-35 70.625 70.925 70.841 70.815 70.539 36-4e 71.339 71.116 13.537 13.039 13.199 41-45 13.570 13.480 13.156 13.717 13.249 46-50 13.577 12.811 12.796 12.813 13.152 51-52 13.079 12.850 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3630 29.3390 29.3450 52.781

.000

.000 59-61 51.350 15.566

.000 READING # 95 AT 8: 6:33 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.848 74.415 74.240 74.387 73.665 6-10 71.701 72.136 72.868 74.000 79.960 11-15 81.174 79.637 82.108 76.976 75.394 16-29 77.532 78.105 72.778 76.473 73.697 21-25 72.842 62.725 71.003 70.008 71.886 26-30 72.429 74.959 70.475 70.650 71.818 31-35 70.672 70.925 70.795 70.861 70.585 36-40 71.292 71.162 13.619 13.167 13.282 i

41-45 13.653 13.471 12.917 13.754 12.827 46-50 13.567 12.939 12.787 12.849 13.143 51-52 13.070 12.841 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3580 29.3350 29.3420 52.880

.000

.000 59-61 31.211 15.679

.000 l

I N S T R UtvtE N T C A L_ I B R A T E D DATA PAGE e1 READING # 96 AT 8:21:33 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 63.048 74.415 74.332 74.434 73.758 6-10 71.747 72.136 72.868 74.093 80.099 11-15 81.360 79.637 81.922 77.023 75.467 16-20 77.578 78.198 72.824 76.320 73.790 21-25 72.934 62.725 71.003 70.008 7;.686 26-30 72.521 75.330 70.475 70.650 71.725 31-35 70.625 70.971 70.841 70.861 70.585 36-40 71.339 71.116 13.537 13.360 13.337 41-45 13.891 13.480 12.972 13.809 12.744 46-50 13.622 12.765 12.842 12.859 13,252 51-52 13.125 12.896 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3610 29.3370 29.3440 52.255

.000

.000 59-61 51.0e8

5.629

.000 READING # 97 AT 8:36:34 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.848

74. 61 74.286 74.434 73.758 6-10 71.747 72.089 72.868 74.046 80.052 11-15 81.313 79.730 82.340 76.976 75.626 16-20 77.578 78.105 72.824 76.427 73.744 21-25 72.642 62.679 71.003 70.008 71.886 26-30 72.429 75.145 70.429 70.636 71.679 31-35 70.579 70.925 70.748 70.861

'O.539 36-40 71.292 71.070 13.454 13.415 13.346 41-45 13.813 13.444 13.027 13.731 13.074 46-50 13.586 12.682 12.851 12.868

3.162 51-52 13.134 12.813 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3590 29.3340 29.3400 52.570

.000

.000 59-61 50.909 15.629

.000 1

i READING # 98 AT 8:51:34 11/25/87 j

l POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.802 74.368 74.193 74.341 73.665 6-10 71.654 72.043 72.729 73.954 80.006 11-15 81.128 79.637 81.968 76.976 75.440 16-20 77.486 77.966 72.685 76.427 73.697 i

21-25 72.842 62.679 70.957 69.962 71.839 26-30 72.382 74.913 70.475 70.742 71.493 31-35 70.579 70.879 70.748 70.815 70.492 36-40 71.246 71.070 13.252 13.121 13.282 41-45 13.978 13.379 12.871 13.713 13.148 46-50 13.522 12.852 12.787 12.849 13.097 U1-52 13.070 12.795 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3570 29.3330 29.3380 52.034

.000

.000 59-61 50.684 15.607

.000

INSTRUMENT C A L_ I B R A T E D DATA PAGE a

READING # 99 AT 9: 6:35 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.802 74.461 74.286 74.387 73.711 6-10 71.701 72.136 72.868 74.046 80.052 11-15 81.313 79.777 81.922 77.023 75.394 16-20 77.532 78.198 72.778 76.520 73.744 21-25 72.888 62.725 71.049 70.003 71.886 26-30 72.475 75.098 70.475 70.742 71.725 31-35 70.625 70.925 70.748 70.815 70.539 36-40 71.292 71.070 13.473 13.979 13.410 41-45 14.606 13.508 "3.229 13.795 13.597 46-50 13.604 12.930 12.824 12.932 13.180 51-52 13.152 12.877 PRESSURE (PSIA)

DEW POINT TEMPERATURE I

53-55,56-58 29.3590 29.3350 23.3400 52.043

.000

. 000l 59-61 50.535 15.620

.000 READING #100 AT 9:21:35 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.895 74.461 74.332 74.434 73.804 6-10 71.793 72.136 72.915 74.139 80.099 11-15 81.360 79.684 82.061 77.069 75.487 16-20 77.378 78.198 72.870 76.613 73.790 21-25 72.380 62.725 71.049 70.101 71.932 26-38 72.475 75.098 70.522 70.835 71.586 31-35 70.625 71.064

'70.795 70.768 70.678 36-40 71.385 71.209 13.317 14.011 13.438 41-45 15.229 13.535 13.073 13.823 13.717 46-50 13.632 12.958 10.851 12.914 13.207 51-52 13.226 12.951 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3600 29.3360 29.3400 51.917

.000

.000 59-61 30.414 15.656

.000.

READING #101 AT 9:36:35 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.802 74.368 74.286 74.341 73.665 6-10 71.654 72.089 72.776 74.000 80.099 11-15 81.406 79.591 82.015 76.930 75.394 16-20 77.486 78.013 72.778 76.473 73.697 21-25 72.795 62.586 70.911 69.962 71.793 26-30 72.336 74.913 70.429 70.789 71.586 31-35 70.532 71.110 71.165 70.768 70.770 36-40 71.617 71.394 13.142 13.378 13.355 41-45 14.143 13.407 12.766 13.740 13.042 46-50 13,503 13.109 12.728 12.836 13.079 51-52 13.143 12.918 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3640 29.3410 29.3470 51.696

.000

.000 59-61 50.265 15.719

.000

I N S T R utvlE N T C A L_ I B R A T E D DATA PAGE 23 READING #102 AT 9:51:36 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.848 74.415 74.332 74.387 73.711 6-10 71.701 72.089 72.822 74.046 80.052 11-15 81.267 79.684 82.618 77.069 75.440 16-20 77.532 78.105 72.778 76.520 73.744 21-25 72.842 62.725 71.003 70.054 71.886 26-30 72.382 75.145 70.614 70.650 71.818 31-35 70.718 71.249 71.212 71.093 71.048 36-40 71.987 71.857 13.197 13.571 13.410 41-45 13.785 13.462 12.862 13.795 12.909 46-50 13.512 13.297 12.824 12.932 13.180 51-52 13.152 12.969 l

PRESSURE (PSIA)

DEW POINT (EMPERATURE 53-55,56-58 29.3720 29.3490 29.3540 51.787

.000

.000 59-61 50.108

'5.625

.000 READING #103 AT 10: 6:36 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.802 74.415 74.332 74.434 73.711 6-10 71.701 72.089 72.822 74.046 82.238 11-15 80.942 79.730 82.525 77.115 75.487 16-20 77.532 78.152 72.824 76.566 73.744 21-25 72.888 62.679 71.049 70.101 71.886 26-30 72.429 75.423 70.661 70.696 71.818 31-35 70.764 71.296 71.212 71.232 71.141 36-40 71.987 71.764 13.243 13.387 13.456 41-45 13.827 13.508 13.367 13.795 12.909 46-50 13.558 13.160 12.824 12.932 13.226 51-52 13.152 12.969 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3710 29.3490 29.3550 51.219

.000

.000 59-61 50.024 15.679

.000 READING #104 AT 10:21:36 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) i 1-5 69.895 74.507 74.379 74.573 73.850 6-10 71.793 72.182 72.915 74.139 80.238 11-15 81.313 79.777 82.479 77.162 75.626 16-20 77.671 78.245 72.870 76.659 73.790 21-25 72.980 62.725 71.142 70.194 72.025 26-30 72.521 75.284 70.800 70.881 72.050 31-35 70.903 71.481 71.490 71.325 71.234 36-40 72.219 72.088 13.353 13.085 13.520 41-45 14.486 13.572 13.707 13.855 13.019 46-50 13.622 13.040 12.888 12.996 13.336 51-52 13.262 13.033 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3710 29.3490 29.3550 51.494

.000

.000 59-61 49.847 15.710

.000

I NSTRt JMENT C A L_ I B R A T E D DATA PAGE 2

READING #185 AT 10:36:37 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.848 74.461 74.379 74.480 73.758 6-10 71.747 72.089 72.868 74.093 80.099 11-15 81.081 79.730 82.618 77.069 75.533 16-20 77.625 78.245 72.824 76.613 73.790 21-25 72.888 62.679 71.049 70.147 71.932 26-30 72.429 75.237 70.800 70.928 71.586 31-35 70.903 71.388 71.443 71.278 71.187 36-40 71.987 71.811 13.353 13.085-13.474 41-45 14.670 13.526 13.798 13.809 13.019 46-50 13.531 13.040 12.888 12.950 13.290 51-52 13.171 12.941 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3690 29.3470 29.3510 51.301

.000

.0001 59-61 49.694 15.634

.000 READING #196 AT 10:51:38 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.848 74.461 74.425 74.526 73.758 6-10 71.747 72.136 72.915 74.093 80.284 11-15 81.267 79.730 82.061 77.069 75.533 16-20 77.578 78.198 72.824 76.613 73.744 21-25 72.334 62.725 71.049 70.194 71.932 26-30 72.429 75.191 70.800 70.835 71.725 31-35 70.857 71.527 71.536 71.093 71.048-36-40 71.756 71.672 13.234 13.374 13.442 41-45 14.734 13.586 14.271 13.873 13.221 46-50 13.590 13.196 12.906 12.969 13.263 51-52 13.143 12.914 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3630 29.3400 29.3460 50.918

.000

.000 59-61 49.541 15.849

.000 READING #197 AT 11: 6:38 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.941 74.554 74.518 74.526 73.850 6-10 71.793 72.182 72.915 74.185 80.238 11-15 81.174 79.823 82.386 77.069 75.672 16-29 77.578 78.198 72.916 76.566 73.837 21-25 72.934 62.771 71.188 70.286 72.025 26-30 72.521 75.237 70.892 71.113 71.910 31-35 70.903 71.620 71.351 71.093 71.002 36-40 71.709 71.579 13.569 13.713 13.506 41-45 14.890 13.604 14.244 13.846 13.923 46-50 13.609 13.577 12.966 12.987 13.368 51-52 13.203 12.978 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3610 29.3370 29.3430 51.112

.000

.000 59-61 49.447 15.787

.000

MSTRUMENT CALI_BRATED DATA PAGE 25 READING #108 AT 11:21:39 11/25/87

{

POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.802 74.461 74.379 74.434 73.758 6-10 71.747 72.089 72.868 74.093 80.377 11-15 80.942 79.684 82.479 77.069 75.394 16-20 77.578 78.245 72.824 76.566 73.790 21-25 72.888 62.679 71.049 70.147 71.'839 26-30 72.475 75.284 70.753 70.835 72.096 31-35 70.764 71.481 70.980 71.046 70.863 36-40 71.570 71.440 13.858 13.814 13.474 41-45 14.991 13.572 14.345 13.809 14.437 46-50 13.577 13.912 12.980 12.950 13.336 51-52 13.262 13.033 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3600 29.3360 29.3420 50.860

.000

.000 59-61 49.298 15.796

.000 READING #109 AT 11:36:40 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.802 74.461 74.379 74.434 73.75a 6-10 71.701 72.089 72.822 74.046 80.284 11-15 81.081 79.823 82.618 77.069 75.579 16-20 77.532 78.059 72.778 76.566 73.697 21-25 72.842 62.725 71.049 70.147 71.747 26-30 72.475 75.098 70.661 70.974 71.864 31-35 70.718 71.342 70.887 71.046 70.770 36-40 71.478 71.301 13.922 13.974 13.447 41-45 15.192 13.499 14.501 13.786 14.501 46-50 13.549 14.344 12.952 12.969 13.400 51-52 13.327 13.006 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3560 29.3350 29.3380 50.752

.000

.000 59-61 49.158 15.809

.000 READING #110 AT 11:51:43 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.415 74.379 74.480 73.711 6-10 71.701 72.089 72.868 74.046 80.238 11-15 81.313 79.684 82.293 76.976 75.348 16-20 77.532 78.105 72.778 76.613 73.744 21-25 72.795 62.725 71.003 70.101 71.700 26-30 72.429 75.145 70.614 70.881 71.818 31-35 70.718 71.296 70.841 70.954 70.770 36-40 71.385 71.255 13.872 14.199 13.396 41-45

~5.417 13.540 14.547 13.781 14.501 46-50 13.590 14.660 12.952 12.923 13.400 51-52 13.368 13.006 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3570 29.3350 29.3380 50.657

.000

.000 59-61 49.069 15.985

.000

I N S T R Utv1E N T CAL IBR ATED DATA PAGE 2:C READING #111 AT 12: 6:44 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.322 74.286 74.341 73.619 6-10 71.608 71.904 72.683 73.907 80.039 11-15 81.174 79.637 82.340 76.883 75.301 16-20 77.393 78.105 72.685 76.566 73.651 21-25 72.749 62.586 70.864 69.962 71.608 26-30 72.290 75.098 70.475 70.789 71.633 31-35 70.579 71.064 70.748 70.861 70.533 36-40 71.292 71.116 13.771 14.465 13.300 41-45 15.550 13.444 14.675 13.681 14.584 46-50 13.*89 14.743 12.851 12.822 13.345 51-52 13.226 13.042 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3560 29.3320 29.3370 50.311

.000

.000 59-61 48.888 16.061

.000 READING #112 AT 12:21:44 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.368 74.286 74.434 73.665 6-10 71.654 71.997 72.776 73.954 80.238 11-15 81.174 79.730 81.875 76.837 75.579 16-20 77.439 78.013 72.731 76.566 73.697 21-25 72.735 62.679 70.957 70.054 71.56; 26-30 72.336 75.145 70.568 70.974 71.493 31-35 70.625 71.064 70.702 70.907 70.63; 36-40 71.339 71.116 14.083 15.277 13.424.

41-45 15.765 13.522 15.033 13.717 14.713 46-56 13.526 14.734 12.929 12.900 13.403 51-52 13.304 13.120 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3580 29.3340 29.3380 50.576

.000

.000 59-61 48.785 15.935

.000 READING #113 AT 12:36:45 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.322 74.332 74.434 73.665 6-10 71.654 71.997 72.776 73.954 80.238 11-15 81.035 79.730 82.525 76.976 75.579 16-20 77.439 78.245 72.778 76.613 73.651 21-25 72.795 62.679 70.957 70.054 71.654 26-30 72.382 75.006 70.522 70.789 71.818 31-35 70.625 70.971 70.656 70.861 70.539 36-40 71.292 71.116 14.152 15.575 13.447 41-45 15.880 13.545 15.052 13.740 14.777 46-50 13.549 14.890 12.952 12.969 13.446 51-52 13.372 13.143 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3540 29.3290 29.3350 50.014

.000

.000 59-61 48.677 15.976

.000

I N S T R U tv1 E N T C A L_ I B R A T E D DATA PAGE 27 l

1 READING #114 AT 12:51:46 11/25/87 l

POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.368 74.332 74.480 73.519 6-10 71.G54 71.997 72.729 74.000 20.145 11-15 81.267 79.730 82.665 77.023 7!.579 16-20 77.439 76.105 72.778 7 6. 6'1 3 71.697 21-25 72.795 62.632 70.911 70.054 71.700 26-30 73.382 75.237 70.522 70.696 73.003 31-35 70.625 70.971 70.748 70.861 70.539 36-40 7;.292 71.116 14.138 15.199 13.433 41-45

'6.141

3.535 15.089 13.726 14.905 46-50 13.581 25.156 12.989 12.914 13.437 51-52 13.317
3.160 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3550 29.3300 29.3330 50.2a8

.000

.000 59-61 AS.510

.5. 346

.000 READING #115 AT 13: 6:46 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.602 74.415 74.425 74.460 73.758 6-10 71.747 72.136 72.868 74.093 60.331 11-15 81.174 79.777 62.340 77.063 75.672 16-20 77.532 78.291 72.824 76.706 73.790 21-25 72.688 62.771 7;.003 70.10; 71.793 26-30 72.475 75.330 70.568 71.113 71.679 31-35 70.672 71.203 71.165 70.86; 70.770 36-40 71.570 71.466 14.427 15.116 13.493 41-45 16.563 13.636 15.373 13.832 14.547 46-50 13.687 15.670 13.030 13.060 12.538 51-52 13.464 13.372 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3610 29.3370 29.3430 49.806

.000

.000 59-61 48.402 15.989

.000 READING #116 AT 13:21:47 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.802 74.461 74.425 74.526 73.758 6-10 71.747 72.136 72.868 74.093 80.284 11-15 81.221 79.730 82.293 77.069 75.719 16-20 77.486 78.198 72.824 76.706 73.790 21-25 72.888 62.771 71.049 70.194 71.886 26-30 72.475 75.376 70.661 70.835 71.910 1

31-35 70.716 71.342 71.212 71.232 71.141 36-40 72.173 72.227 14.450 15.144 13.520 41-45 16.728 13.664 15.630 13.809 16.177 46-50 13.755 16.203 13.072 13.088 13.473 1

51-52 13.446 13.354 i

PRESSURE (PSIA)

DEW POINT TEMPERATURE

{

53-55,56-58 29.3730 29.3480 29.3540 49.8;l

.000

.000 59-61 48.272

.6.057

.000

INSTRUMENT C AL_ I B R ATED DATA PAGE 12:'

READING #117 AT 13:36:48 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.322 74.286 74.480 73.665 6-10 71.654 72.043 72.776 74.000 80.099 11-15 80.649 79.637 82.386 76.976 75.4G7 16-20 77.333 78.152 72.778 76.566 73.697 21-25 72.795 62.725 71.003 70.101 71.839 26-30 72.475 75.376 70.707 70.835 71.771 31-35 70.A11 71.J42 71.165 71.325 71.234 36-40 72.126 71.949 14.854 15.181 13.465 41-45 16.352 13.609 15.759 13.754 16.264 46-50 13.75; 15.643 13.017 13.033 13.464 j

51-52 13.*e2 13.253 i

PRESSURE (PSIA)

DEW POINT TEMPERATURE l

53-55,56-58 29.3670 29.3420 29.3480 49.73;

.020

.000' 59-61 46.173 15.946

.007 READING #118 AT 13:51:49 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.602 74.461 74.425 74.619 73.604 6-10 71."93 72.162 72.915 74.093 60.331 11-15 80.003 79.823 82.804 77.023 75.765 16-20 77..32 78.245 72.370 76.706 73.637 21-25 72.950 62.817 7;.142 70.286 71.932 26-30 72.568 75.376 70.846 71.067 72.203 31-35 70.903 71.573 71.490 71.232 71.1G7 36-40 71.941 7

764 15.231 16.474 13.474 41-45 16.320

3.710 15.722 13.859 15.768 46-50 13.697 15.652
13. 63 13.066 13.657 51-52 13.563 13.400 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3540 29.3430 29.3460 49.622

.000

.000.

59-61 46.065 15.953

.020-READING #119 AT 14: 6:50 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.4;3 74.379 74.526 73.714 6-10 71.701 72.043 72.822 74.046 80.236 11-15 61.221 79.777 82.386 77.069 75.579 16-20 77.486 76.245 72.778 76.706 73.744 21-25 72.84Z 62.771 71.043 70.147 71.747 26-30 72.475 75.264 70.753 71.067 71.910 31-35 70.764 71.527 71.397 70.954 70.956 36-40 71.617 71.486 15.653 17.075 13.483 41-45

6.329 13.673 15.364 13.777 15.410 46-50 13.906 15.615 13.127 13.005 13.574 51-52 13.546 13.317 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3600 29.3380 29.3410 49.474

.000

.000 59-61 47.9;I 16.088

.000-

l i

I N S T R LJiv1E N T C3 A L. I B R A T E D DATA PAGE 3E: 9 i

READING #120 AT 14:21:50 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) i 1-5 69.502 74.461 74.375 74.619 73.604 6-10 71.793 72.136 72.315 74.033 87.331 11-15 81.;74 75.916 82.665 77.162 7!.672 16-20 77.578 76.245 72.870 76.736 73.637 21-25 72.934 62.864 71.142 70.240 7' ; a39 26-30 72.568 75.469 70.800 71.067 7.

673 31-35 70.811 71.573 71.165 71.046 70.863 36-40 71.617 7.

486

.6.030 17.727 13.676 41-45

.6.517 13.726 15.373 13.878 15.262 46-50 13.961

.5.624 13.227 13.152 13.721 l

l l

51-52 13.E01 13.464 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3600 29.3360 29.3410 49.649

.000

.000 59-61 47.63; 15.362

.000 READING #121 AT 14:36:52 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.348 74.507 74.472 74.665 73.650 6-10 71.640 72.22G 72.961 74.185 60.377

{

11-15

81. 74 73.916 82.897 77.162 73.61.

16-20 77.~78 78.291 72.870 76.752 73.663 21-25 72.334 62.864 71.096 70.286 7;.533 26-30 72.56G 75.330 70.500 70.928

-72.036 31-35 70.857 71.573 70.380 71.139 70.309 36-40 71.570 71.466

.6.425 16.034 13.743 41-45 16.590 13.755 15.355 13.35;

5.722 46-50 14.035 1 5. 6'2 6 13.3
1 13..80 13.749 51-52 13.675 13.491 PRESSURE (PSIA)

DEW POINT TEMPERATURE 3

53-55,56-58 29.3600 29.3334 23.3430 49.518

.000

.000 59-61 47.709 1G.0;2

.000 READING #122 AT 14:51:53 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.802 74.4;5 74.373 74.573 73.758 6-10 71.701 72.089 72.866 74.033 60.331 11-15 81.267 79.869 82.665 77.115 75.713 16-20 77.532 78.245 72.824 76.752 73.790 j

21-25 72.886 62.864 71.049 70.134 7;.700 26-30 70.521 75.330 70.707 70.928 71.635 31-35 70.718 71.388 70.887 71.093 70.770 36-40 71.431 71.301 16.443 18.323 13.768 41-45 16.471 13.728 15.373 13.878 15.833 46-50 14.007 15.762 13.227 13.152 13.721 51-52 13.601 13.464 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3590 29.3370 23.3430 49.158

.000

.000 59-61 47.597 16.106

.000

I N S T R UtvlE N T CAL I BR ATED DATA PAGE 3

READING #123 AT 15: 6:54 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.802 74.461 74.425 74.573 73.304 6-10 71.793 72.182 72.915 74.093 62.334 11-15 81.453 79.823 82.293 77.2:8 75.765 16-20 77.486 78.245 72.870 75.752 72.790 21-25 72.888 62.864 71.096 70.286 72.747 26-30 72.568 75.654 70.753 70.881 72.033 31-35 70.857 71.388 70.934 71.093 7:.770 36-40 71.524 71.347 15.176 18.112

13. 9G5 41-45 17.452 13.792 15.805 13.891 16.443 46-50 14.067 16.010 13.292 13.170 13.694 51-52 13.711 13.528 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3550 29.3340 29.3390 49.253

.200

. 000l 59-61 47.530

C.079

.005 READING #124 AT 15:21:54 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.368 74.332 74.526 73.714 6-10 71.701 72.089 72.822 74.000 52.33'.

11-15

81. 74 79.730 82.247 77.115 75.672 16-20 77.t32 78.198 72.824 76.752 73.790 21-25 72.a42 62.817 71.049 70.194 7

654 26-30 72.521 75.376 70.661 70.974 71.957 31-35 70.672 71.249 70.795 71.000 70.770 36-40 71.365 71.209 15.157 18.273 13.932 41-45 17.571 13.723 15.787 13.873

.6'.746 46-50 14.003 16.308 13.073

3.152
3.62

51-52 13.734 13.505 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3550 29.3350 29.3390 49.077

.000

.000 59-61 47.399

6.084

.0!0 READING #125 AT 15:36:55 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.368 74.332 74.526 73.758 6-10 71.701 72.069 72.066 74.000 60.423 11-15 81.221 79.823 82.293 77.023 75.579 16-20 77.439 78.152 72.778 76.752 72.744 21-25 72.842 62.817 70.957 70.147 71.700 26-30 72.475 75.284 70.614 71.159 71.864 31-35 70.764 71.157 70.795 70.954 70.631 36-40 71.385 71.209 15.203 17.727 13.992 41-45 17.296 13.769 15.603 13.873 16.241 46-50 14.003 16.630 13.227 13.152 13.625 1

51-52 13.734 13.459 l

l PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3540 29.3320 29.3360 48.911

.000

.000:

59-61 47.313 15.976

.000 l

l

INSTRUMENT C A L. I B R A T E D DATA PAGE 31 READING #126 AT 15:51:56 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.415 74.379 74.573 73.604 6-10 71.747 72.089 72.822 74.000 60.331 11-15 81.313 79.823 62.572 77.023 75.579 16-20 77.436 78.152 72.824 76.752 73.790 21-25 72.888 62.817 71.003 70.147 71.702 26-30 72.475 75.237 70.661 71.067 71.771 31-35 70.718 71.110 70.841 70.954 70.585 36-40 71.285 71.209 15.148 17.672 13.937 41-45 16.966 13.806 15.777 13.864 1C.048 46-50 14.285 16.666

3.264 13.143 13.661 51-52

.3.725 13.501 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3520 29.3290 29.3340 48.992

.000

.20J 59-61 47.160

6.196

.000 READING #127 AT 16: 6:57 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.366 74.332 74.480 73.71.

6-10 71.701 72.089 72.776 74.000 60.334 11-15 81.081 79.777 82.479 77.162 75.533 16-20 77.439 78.245 72.778 76.798 73.744 21-25 72.842 62.817 71.003 70.147 71.700 26-30 72.475 75.006 70.568 70.928 71.725 1

31-35 70.718 71.016 70.748 70.861 70.539 36-40 71.385 71.162

.5.194 17.534 13.337 41-45 17.058 13.80G 16.046 13.818 16.048 46-50 14.085 16.529 13.264 13.143 13.707 51-52 13.771 13.546 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3520 29.3290 23.3320 48.731

.000

.000 59-61 47.070 16.169

.000 READING #128 AT 16:21:58 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.663 74.322 74.240 74.526 73.665 6-10 71.654 71.997 72.729 73.954 80.331

{

11-15 81.174 79.684 G1.968 76.976 75.487 I

16-20 77.333 78.105 72.731 76.659 73.697 21-25 72.842 62.679 70.911 70.0S4 71.608 26-30 72.429 75.145 70.475 70.835 71.725 31-35 70.625 70.925 70.656 70.815 70.539 36-40 71.246 71.070 15.194 16.846 13.845 41-45 17.471 13.760 16.508 13.772 16.002 46-50 13.994 16.299 13.218 13.097 13.707 51-52 13.725 13.455 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3500 29.3270 29.3310 48.551

.000

.000 59-61 46.931 16.196

.000

_I_N S T R U M EE N T C A L._ I B R A T E D DATA P A G EE 3c READING #129 AT 16:36:59 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.663 74.322 74.332 74.480 73.711 6-10 71.701 72.043 72.776 73.954 80.284 11-15 81.035 79.777 82.479 76.976 75.579 16-20 77.393 78.152 72.776 76.706 73.697 21-25 72.842 62.771 70.911 70.054 71.561 26-30 72.429 75.284 70.661 71.113 71.725 31-35 70.532 70.925 70.702 70.815 70.452 36-40 71.246 71.070 15.102 16.662 13.896 41-45 17.608 13.811 16.650 13.823

!.5.361 46-50 14.044 16.212 13.264 13.143 13.712 51-52 13.776 13.546 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3470 29.3230 29.3280 48.632

.000

.000:

59-61 46.859 16.156

.000)

READING #130 AT 16:52: 0 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.368 74.379 74.526 73.758 6-10 71.793 72.136 72.868 74.000 60.284 11-15 80.588 79.869 82.665 77.115 75.579 16-20 77.439 78.152 72.870 76.752 73.790 21-25 72.642 62.864 71.049 70.194 71.747 26-38 72.521 75.330 70.614 70.928 71.725 31-35 70.672 71.018 70.795 70.907 70.631 36-40 71.339 71.162 15.359 16.690

3.965 41-45 17.361 13.838 16.903 13.937 15.989 46-50 14.158 16.148 13.357 13.216 13.785 51-52 13.799 13.620 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3490 29.3240 29.3290 48.362

.000

.000 59-61 46.733 16.223

.000 READING #131 AT 17: 7: 1 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.368 74.332 74.480 73.665 6-10 71.701 72.043 72.822 74.000 80.377 11-15 80.942 79.823 82.479 77.023 75.533 16-20 77.333 78.152 72.778 76.752 73.697 21-25 72.842 62.817 71.003 76.147 71.608 26-30 72.429 75.052 70.614 70.974 71.679 31-35 70.625 70.971 70.748 70.907 70.539 36-40 71.339 71.116 25.405 16.465 14.015 41-45 17.131 13.884 46.632 13.850 16.310 46-50 14.117 16.056 13.337 13.125 13.739 51-52 13.711 13.620 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3450 29.3229 29.3260 48.119

.000

.000 59-61 46.616 16.367

.000 j

INSTRUMENT C A L_ I B R A T E D DATA PAGE 33 READING #132 AT 17:22: 2 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.802 74.461 74.425 74.619 73.G24 6-10 71.840 72.228 72.961 74.139 80.236 11-15 81.406 79.916 82.247 77.162 75.672 16-20 77.578 78.291 72.963 76.891 73.883 21-25 72.934 62.956 71.142 70.240 71.793 26-30 72.614 75.330 70.707 71.067 71.957 31-35 70.764 71.064 70.841 70.954 70.678 36-40 71.431 71.255 15.497 16.414 14.148 41-45 17.131 14.017

'6.489 14.029 16.719 46-50 14.250 16.285 13.475 13.308 13.831 51-52 13.936 13.757 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3480 29.3230 29.3290 46.277

.000

.000 59-61 46.585 16.295

.000 READING #133 AT 17:37: 3 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.461 74.472 74.619 73.758 6-10 71.793 72.136 72.868 74.093 80.238 11-15 81.953 79.916 82.247 77.162 75.579 16-20 77.486 78.291 72.870 76.845 73.837 21-25 72.688 62.910 71.003 70.194 71.700 26-30 72.521 75.237 70.614 71.205 71.725 31-35 70.625 70.97; 70.746 70.861 70.539 36-48 71.339 71.116 15.442 16.272 14.189 41-45 17.076 13.966 16.393 13.978 16.484 46-50 14.200 16.460 13.420 13.207 13.776 51-52 13.886 13.748 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3460 29.3230 29.3280 48.173

.000

.000 59-61 46.481 16.336

.000 READING #134 AT 17:52: 4 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.802 74.415 74.379 74.665 73.804 6-10 71.640 72.182 72.915 74.093 80.377 11-15 81.035 79.916 82.432 77.023 75.626 16-20 77.486 78.105 72.916 76.798 73.790 1

21-25 72.934 62.864 71.003 70.194 71.793 26-30 72.614 75.145 70.661 71.159 71.818 31-35 70.672 70.971 70.795 70.861 70.539 l

36-40 71.385 71.162 15.589 16.414 14.~46 41-45 17.085 14.017 16.305 13.983 16.351 46-50 14.250 16.648 13.475 13.262 13.831 51-52 13.936 13.711 PRESSURE (PSIA)

DEW POINT TEMPERATURE l

53-55,56-58 29.3450 29.3220 29.3270 48.060

.000

.000

{

59-61 46.373 16,295

.000 l

I N S T R Utv1E N T C A L. I B R A T E D DATA PAGE 3

READING #135 AT 18: 7: 5 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.415 74.425 74.573 73.756 6-10 71.747 72.136 72.868 74.046 80.377 11-15 61.221 79.869 82.233 76.920 75.626 16-20 77.486 78.245 72.870 76.798 72.790 21-25 72.888 62.817 70.957 70.101 71.700 26-30 72.521 75.191 70.614 70.928 7;.493 31-35 70.672 70.971 70.702 70.615 70.492 36-40 71.292 71.070 15.469 16.525 14.075 41-45 17.196 13.989 16.278 13.955 16.278 46-50 14.223 16.529 13.448 13.280 13.845 51-52 13.954 13.634 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3440 29.3230 29.3280 47.934

.000

.000 59-61 46.274 16.322

.002 READING #136 AT 18:22: 5 11/25/87

~

POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.368 74.425 74.573 72.711 6-10 71.747 72.089 72.822 74.046 62.377 11-15 80.895 79.869 82.432 76.976 75.626 16-20 77.486 78.245 74.870 76.845 73.790 21-25 72.934 62.910 70.957 70.10; 7;.608

(

26-30 72.52; 75.191 70.568 70.833 71.586 31-35 70.625 70.971 70.702 70.815 70.585 1

36-40 71.292 71.070

5.662 17.176 14.088 l

41-45 17.251 13.957 16.475

3.969 16.292 i

46-50 14.232 16.359 13.457 13.290 a3.813 51-52 13.922 13.E.93 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3410 29.3190 29.3240 47.881

.000

.000 59-61 46.202 16.295

.0e0 READING i4137 AT 18:37: 6 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.415 74.379 74.573 73.804 6-10 71.793 72.126 72.822 74.046 60.377 11-15 80.988 79.916 82.386 77.115 75.579 16-20 77.439 78.152 72.824 76.798 73.730 21-25 72.888 62.817 70.957 70.101 71.700 26-30 72.521 75.145 70.568 70.328 71.771 31-35 70.579 70.925 70.609 70.815 70.446 36-40 71.246 71.070 15.469 17.213 14.125 41-45 17.150 13.994 16.374 14.006 16.282 46-50 14.268 16.350 13.448 13.280 13.850 51-52 13.313 13.684 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3400 29.3190 29.3230 47.858

.000

.000 59-61 46.076 16.345

.020

i I

i INSTRUMENT CALIBRATED DATA A A G EE 35 READING #138 AT 18:52: 7 11/25/87 POINTS:

TEMPERATURE (FRHRENHEIT) 1-5 69.663 74.368 74.332 74.526 73.711 6-10 71.747 72.089 72.822 74.000 80.284 11-15

81. 28 79.777 62.523 76.976 73.672 16-20 77.393 78.198 72.870 76.7'98 73.790 21-25 72.888 62.771 70.911 70.101 71.608 26-30 72.475 75.145 70.522 70.974 71.586 31-35 70.532 70.833 70.609 70.815 70.400 36-40 71.246 71.023 15.469 16.575 14.263 41-45 17.287 13.994 16.237 13.960 16.19.

46-50 14.227 16.487 13.448 13.239 13.804 51-52 13.821 13.638 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3420 29.3190 29.3240 47.916

.000

.200 59-61 45.986 16.338

.000 READING #139 AT 19: 7: 8 11/25/87 s

POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.415 74.425 74.573 73.758 6-10 71.33 72.136 72.868 74.093

60. 40 11-15 80.9*2 79.916 82.386 77.162 7L 719 16-20 77.466 78.145 72.916 76.845 73.883 21-25 72.980 62.956 71.003 70.194 71.747 26-30 72.568 75.376 70.568 71.205 71.357 31-35 70.579 70.371 70.656

'70.861 70.539 36-40 71.292 71.116 15.626 16.497 14.46f 41-45 17.718 14.104 16.393 14.065 15.704 46-50 14.287 16.868 13.558 13.345 13.3;*

51-52 13.840 13.746 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,36-58 29.3430 29.3200 29.3240 47.475

.000

.000 59-61 45.928 16.38

.000 READING #140 AT 19:22: 8 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.663 74.368 74.379 74.523 73.758 j

5 6-10 71.701 72.~36 72.822 74.200 80.238 i

l 11-15 81.221 79.823 82.990 76.883 75.626 16-20 77.346 78.245 72.870 76.752 73.744 21-25 72.888 62.817 70.957 70.101 71.654 26-30 72.521 75.145 70.522 70.835 71.818 31-35 70.486 70.925 70.609 70.768 70.492 36-40 71.246 71.023 15.414 16.199 14.391 41-45 17.599 14.031 16.549 14.042 17.095 46-50 14.264 17.300 13.438 13.271 13.734 51-52 13.812 13.675 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3420 29.3190 29.3230 47.448

.400

.000 59-61 45.815 16.421

.000 s

(

4 6 T N S T R UtvlE N T QA L_ I B R A T E D D GeT A PAGE 3d 4

/

(

READXNG #141 AT 19:37:.9 11/25/87 POINTSr*

TEMPERATURE (FAHRENHEIT) 1-5 6_.663 74.368 74.332 74.526 73.665 6-19 71.701 72.089 72.822 74.046 80.423 11-15 81.035 79.823 82.432 77.023 75.079 16-2tf 77.439 78.105 72.824 76.798 73.790 21-25 72.888 62.864 70.911 70.054 71.654 26-38 72.521 75.330 70.522 70.928 71.664

.)

31-35 70.579 70.833 70.609 70.768 70.446 36-49 71.200 71.023 15.993 16.589 14.322 41-45, '

17.214 14.058 16.756 14.065 17.306 46-58 14.287 16.685 13.512 13.299 13.822 51-52 14.018 13.748 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3430 29.3190 29.3240 47.426

.000

.000 59-61 45.765 16.416

.000 READING #142 AT 19:52:11 11/25/87 POINTG:

TEMPERATURE (FAHR"ENHEIT) 1-5 69.663 74.322 74.379 74.526 73.711 6-19 71.747 72.043 72.776 74.000 80.284 11-15 81.235 79.823 82.711 77.069 75.487 16-29 77.393 78.105 72.824 76.798 73.744 21-25 72.888 62.817 70.864 70.008 71.608 26-38 72.521 75.237 70.475 70.742 71.493 31-35 70.486 70.833 70.517 70.722 70.400 36-48 71.200 71.023 16.108 17.213 14.258 41-45 16.920 14.035 16.324 14.047 16.553 46-54 14.268 16.437 13.493 13.280 13.799 51-52 13.954 13.679 PRTSSURE (PSIA)

DEW POINT TEMPERATyRE 53-55,56-58 29.3430 29.3200 29.3250 47.224

.000

.000 59-61 45.657 16.349

.,000 READING #143 AT 29: 7:11 11/25/87 7',

a POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.617 74.322 74.332 74.526 73.711 6-10 71.701 72.043 72.776 74.000 80.377 11-15 81.081 79.823 82.711 77.069 75.626 16-20 77.439 78.152 72.824 76.798 73.744 21-25 72.842 62.064 70.911 70.05L 71.600 26-30 72.521 75.237 70.475 70.742 71.586 31-35 70.532 70.879 70.563 70.768 70.353 3

36-48 71.200 71.023 15.800 17.130 14.359 vH 41-45 17.113 14.095 16.154 14.102 16.383 46-50 14.278 16.497 13.503 13.336 13.905 51-52 14.060 13.785 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3410 29.3170 29.3200 47.269

.000

.000 59-61 45.541 16.421

.000

1

+

IN ST R@l2i~hLT C ALJ BN ATED DATA PAGE 37 READING #144 AT 20:22:13 11/25/87 P3!NTCt TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.415 74.379 74.665 73.758 6-19 71,747 71.t36 72.868 74.093 80.377 11-15

81. 0/31 73.623 82.432 77.115 75.626 l'6-29 77.48G 78.157 72.870 7 6. 8'9 1 73.750 21-25 73.934 62.864 70.957 70.147 71.608 26-30 72.568 75.264 70.568 70.881 71.818 31-35

'.' 0. G 2 5 70.971 70.609 70.815 70.492 36-49 71.200 71.023 15.883 17.075 14.350

/

41-45 17.425 14.481 16.324 14.093 16.416

/

46-58 14.314 1G3391 13.448 13.326 13.937

'i

'j51-52 14.092 13 d17 a

4 PRESSURE (PS I A !'

DEW POINT TEMPERATURE 53-55,56-58 29.3420 29.3170 29.3210 47.165

.000

.000 59-61 45.491 16.403

.002 READING #14$ AT 20:37:14 11/25/67 PD,INTS:

7EMPERATURE (FAHR'ENHEIT)

I" 5 69.709 74.415 74.379 74.619 73.758 d-16

'1.747 72.136 72.868 74.046 80.377 11-15 81.235 79.910 82.525 77.023 75.672 16-29 77.439 78.29i 72.916 76.845 73.837 21-25 72.93'+

62.864 70.957 70.101 71.654 26-38 72.550 75.284 70.614 70.881 71.679 31-35 70.6&S 70.879 70.656 70.815 70.539

(

36-48 7.'.Cw6

  • 1.070 15.745 16.938 14.487

/

41-45 17.37G 14.127 16.278 14.184 16.783

\\

46-50 14.40C 16.391 13.446 13.336 13.937 51-52 1,.138 13.909 9 p ;,

PRESLURE (PSIA)

DEW POINT TEMPERATURE s

\\

33-55,56-58 29.3440 29.3130 29.3220 47.070

.000

.000 59-61 45.392 16.349

.000 READING #146 AT 20:52:15 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.6E3 74.368 74.379 74.619 73.711 6-18 71.701 7G.089 72.822 74.046 80.238 11-15 80.938 79.916 82.757 76.837 75.533 j

16-P9 77.393 70.198 72.824 76.891 73.790 21-20 72.888 62.064 70.911 70.054 71.654 26-39 72.521 7%,376 70.522 70.742 71.540 31-35 70.532 78.786 70.563 70.768 70.492 l

36-48 71.200 71.c23 15.662 16.763 14.451 41-45 17.251 14.0*9 16.429 14.102 16.884

\\46-58 14.369 16.634 13.457 13.336 13.859 1

51-52 14.106 13.831

\\

PRESSURE (PS!ni DEW POINT TEMPERATURE 53-55, 56-Go 29.3*43 29.3150

&9.3190 47.043

.000

.000

%9-61 45.306 16.444

.000

INSTRUMENT C A L_ I B R A T E D DATA PAGE 3

READING #147 AT als 7:15 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.415 74.425 74.619 73.758 6-19 71.793 72.182 72.915 74.093 80.284 11-15 81.081 79.869 82.432 76.976 75.672 16-29 77.439 78.245 72.916 76.845 73.883 25-25 72.934 62.910 70.957 70.147 71.747 26-38 72.614 75.469 70.568 71.159 71.540 31-35 70.625 70.925 70.656 70.815 70.539 36-48 71.246 71.070 15.690 17.571 14.386 41-45 18.058 14.164 16.774 14.175 17.141 46-58 14.443 16.565 13.530 13.409 13.927 51-52 14.174 13.945 l

PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3400 29.3150 29.3210 46.836

.000 000 59-61 45.216 16.421 000 READING #148 AT 21:22:16 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.507 74.472 74.665 73.804 6-19 71.886 72.182 72.915 74.139 80.423 11-15 81.313 79.962 82.711 77.162 75.719 16-29 77.532 78.384 72.963 76.938 73.883 21-25 73.027 62.956 71.003 70.147 71.793 26-38 72.660 75.330 70.614 71.020 71.632 31-35 70.672 70.971 70.609 70.861 70.539 36-48 71.339 71.116 15.690 17.617 14.432 41-45 18.058 14.255 16.682 14.267 17.462 46-58 14.488 16.749 13.622 13.501 13.973 51-52 14.266 13.991 PRESSURE (PSIA)

Dt'.W POINT TEPPERATURE 53-55,56-58 29.3400 29.3160 29.3210 46.836

.000 000-59-61 45.122 16.412 000 READING #149 AT 21:37:17 11/25/87 POINTS:

TEMPERATURE (FAHREPeiEIT) 1-5 69.709 74.415 74.425 74.665 73.850 6-18 71.793 72.182 72.868 74.139 80.377 11-15 80.980 79.962 83.175 77.208 75.626 16-29 77.486 78.245 72.963 76.938 73.929 21-25 72.934 63.003 70.957 70.147 71.793 26-38 72.614 75.145 70.568 71.020 71.540 31-35 70.672 70.879 70.656 70.861 70.492 36-48 71.246 71.070 15.754 17.038 14.634 41-45 17.842 14.182 16.287 14.285 16.838 46-58 14.507 16.951 13.590 13.468 13.992 51-52 14.238 14.055 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3410 29.3150 29.3200 46.643

.000

.000 59-61 45.068 15.746

.0001

I N S T R Utv1E N T C A L_ I B R A TE D DATA PAGE 39 READING #150 AT 21:52:18 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.368 74.379 74.573 73.711 6-18 71.793 72.182 72.915 74.046 80.284 11-15 81.221 79.962 82.479 77.069 75.579 16-29 77.439 78.245 72.916 76.845 73.837 21-25 72.934 62.910 70.957 70.101 71.747 26-39 72.660 75.145 70.568 71.020 71.725 31-35 70.625 70.925 70.702 70.768 70.565 36-49 71.292 71.070 15.681 17.194 14.652 41-45 17.361 14.200 16.305 14.212 16.627 46-59 14.433 17.061 13.521 13.400 13.969 51-52 14.211 14.028 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3390 29.3140 29.3190 46.616

.000

.000 59-61 44.982 14.616

.000 READING #151 AT 22: 7:19 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.461 74.472 74.619 73.804 6-10 71.640 72.228 72.915 74.133 80.238 11-15 80.988 79.916 82.850 77.208 75.672 16-29 77.486 78.291 72.963 76.984 73.883 21-25 72.980 62.956 71.003 70.101 71.747 26-39 72.660 75.376 70.522 70.974 71.725 31-35 70.579 70.925 70.609 70.861 70.492 36-48 71.246 71.116 15.736 17.158 14.707 41-45 17.370 14.209 16.728 14.221 16.490 46-58 14.488 16.933 13.622 13.501 14.019 51-52 14.220 14.037 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3380 29.3130 29.3180 46.710

.000

.000 59-61 44.938 14.949

.000 READING #152 AT 22:22:20 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.415 74.425 74.665 73.758 6-18 71.792 72.136 72.868 74.046 80.331 11-15 80.895 79.916 82.061 77.208 75.626 16-29 77.486 78.198 72.870 76.891 73.837 21-25 72.980 62.910 70.911 70.054 7 1.-7 4 7 26-30 72.568 75.469 70.475 70.974 71.540 31-35 70.579 70.879 70.563 70.768 70.539 36-48 71.200 71.023 15.626 16.681 14.689 41-45 17.902 14.191 16.939 14.294 16.572 46-58 14.470 16.685 13.649 13.482 14.005 51-52 14.293 14.069 l

PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3350 29.3130 29.3180 46.477

.000

.000 59-61 44.847 15,755

.000

I N S T R UlvlE N T CALIBRATED DATA PAGE 4

READING #153 AT 22:37:22 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.461 74.425 74.619 73.758 6-10 71.840 72.228 72.915 74.139 80.377 11-15 81.174 79.916 82.616 77.162 73.672 16-29 77.532 78.337 73.009 76.938 73.929 21-25 72.980 63.003 71.003 70.101 71.747 26-38 72.660 75.469 70.568 71.159 71.632 31-35 70.625 70.879 70.609 70.768 70.539 36-4e 71.246 71.070 15.800 16.534 14.726 41-45 17.934 14.228 17.160 14.331 16.471 46-59 14.553 16.584 13.727 13.468 14.083 i

51-52 14.330 14.101 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3400 29.3160 29.3200 46.314

.000

.000 59-61 44.785 16.363

.000-READING #154 AT 22:52:23 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.802 74.461 74.425 74.665 73.850 6-18 71.886 72.228 72.961 74.*39 80.377 11-15 81.267 79.962 82.293 77.208 75.811 16-28 77.532 78.291 73.009 76.891 73.929 21-25 72.980 62.956 71.003 70.121 71.793 26-38 72.660 75.284 70.568 70.881 71.725 31-35 70.625 70.925 70.656 70.861 70.539 36-48 71.292 71.116 15.828 16.515 14.845 41-45 17.599 14.255 17.325 14.358 16.406 46-Se 14.626 16.428 13.801 13.501 14.065 51-52 14.312 14.175 i

PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3370 29.3140 29.3190 46.400

.000

. 000 l 59-61 44.695 16.507

.000 READING #155 AT 23: 7:25 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.461 74.332 74.665 73.758 6-19 71.840 72.182 72.915 74.139 80.331 11-15 80.988 79.962 82.804 77.208 75.765 16-28 77.532 78.337 72.963 76.891 73.883 21-25 72.980 62.956 70.911 70.254 71.747 26-3e 72.614 75.515 70.522 70.928 71.818 31-35 70.625 70.879 70.563 70.815 70.446 36-49 71.246 71.070 15.855 16.451 14.872 41-45 17.443 14.237 16.893 14.340 16.664 46-Se 14.562 16.414 13.787 13.528 14.051 51-52 14.293 14.156 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3350 29.3110 29.3160 46.404

.000

.000 4

i 59-41 44.641 16.583

.200

I N E T R utvtE N T C A L_ I B R A T E D DATA P AG EE 41 READING #156 AT 23:22:25 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.415 74.379 74.GG5 73.758 6-19 71.840 72.182 72.915 74.139 80.33t 11-15 81.267 79.916 82.572 77.0:23 75.719 16-29 77.486 78.337 72.916 76.845 73.G83 21-25 72.934 63.003 70.911 70.054 71.700 26-39 72.660 75.469 70.475 70.974 7).679 31-35 70.579 70.879 70.517 70.815 70.492 36-49 71.246 71.116 15.855 16.314 14.918 41-45 17.263 14.283 16.664 14.386 16.939,

46-59 14.608 16.460 13.787 13.528 14.097 51-52 14.339 14.156 PRESSURE (PSIA)

D W POINT TEMPERATURE 53-55,56-58 29.3350 29.3110 29.3150 46.184

.000

.000 59-61 44.550 16.534

.000 READING #157 AT 23:37:26 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.415 74.379 74.665 73.750

~

6-19 71.040 72.136 72.868 74.093 00.331 11-15 81.061 79.962 82.665 77.254 75.672 16-29 77.486 78.245 72.916 76.538 73.883 21-25 72.934 62.956 70.864 70.0S*

;. 7 4 7 26-38 72.614 75.469 70.522 70.661 71.566 31-35 70.579 70.833 70.517 70.766 70.446 36-49 71.246 71.070 15.846 16.213 14.863 41-45 17.159 14.274 16.655 14.377 16.700-46-58 14.553 16.676 13.773 13.468 14.083 51-52 14.284 14.101 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3330 29.3090 29.3130 46.283

.000

.000 59-61 44.474 16.655

.000 READING #158 AT 23:52:27 11/25/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.415 74.425 74.619 73.806 6-19 71.793 72.182 72.915 74.093 80.331 11-15 81.174 79.962 82.236 77.162 75.6.16 16-29 77.532 78.291 72.916 76.891 73.837 21-25 72.934 62.956 70.911 70.101 71.793 26-39 72.614 75.423 70.475 70.835 71.493 31-35 70.579 70.879 70.563 70.815 70.492 36-40 71.246 71.070 15.892 16.350 14.909 41-45 17.205 14.278 16.567 14.377 16.567 46-58 14.598 16.813 13.824 13.519 14.088 51-52 14.330 14.197 PRESSURE (PSIA)

DEU PGINT TEMPERATURE 53-55, 56-58 29.3340 29.3100 29.3150 46.130

.000

.000 59-61 44.397 16.588

.000

INSTRUMENT CALIBRATED DATR PAGE 4(

l READING #159 AT 0: 7:28 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.848 74.554 74.518 74.804 73.897 6-10 71.932 72.228 73.007 74.232 80.284 11-15 81.174 80.009 82.618 77.301 75.811 16-29 77.578 78.337 73.055 77.630 73.976 21-25 73.027 63.003 72.957 70.147 71.747 26-39 72.707 75.562 70.568 71.067 71.771 31-35 70.672 70.925 70.656 70.861 70.492 36-48 71.292 71.116 15.919 16.607 14.799 41-45 17.370 14.347 16.682 14.450 16.5?S 46-58 14.718 16.841 13.938 13.638 14.157 51-52 1 4. 3 5 P, 14.266 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3350 29.3110 29.3160 45.932

.000

.000 59-61 44.352 16.59G

.000 READING #160 AT 9:22:29 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.415 74.425 74.619 73.804 6-19 71.686 72.162 72.915 74.139 82.423 11-15 81.281 79.962 82.897 77.115 75.672 16-29 77.436 78.291 72.963 76.891 73.883 21-25 72.980 63.003 70.911 70.054 71.793 26-39 72.614 75.330 70.522 70.881 71.540 31-35 70.532 70.833 70.609 70.722 70.400 36-44 71.246 71.023 15.984 17.038 4.680 41-45 17.342 14.320 16.655 14.422 16.521 46-58 14.690 16.542 13.869 13.565 14.088 51-52 14.330 14.243 PRESM.JRE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3350 29.3090 29.3130 45.896

.000

.000 59-61 44.276 16.619

.000 READING #161 AT 0:37:38 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.415 74.379 74.619 73.758 6-18 71.793 72.136 72.822 74.046 80.238 11-15 80.849 79.916 82.525 77.069 75.672 16-29 77.486 78.337 72.916 76.938 73.883 21-25 72.934 62.956 70.864 70.101 71.747 26-38 72.614 75.284 70.429 70.974 71.586 31-35 70.532 70.879 70.517 70.768 70.446 36-48 71.246 71.070 15.947 17.185 14.735 41-45 17.306 14.329 16.572 14.386 16.439 46-58 14.653 16.552 13.879 13.528 14.097 51-52 14.339 14.248 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3330 29.3080 29.3130 45.838

.000

.000 59-61 44.213 16.484

.000

INSTRUMENT C A L_ I B R A T E D DATA PAGE 43 1

RERDING #162 AT 0:52:32 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.368 74.379 74.619 73.758 6-18 71.840 72.182 72.868 74.046 8.184 11-15 81.313 79.869 82.479 77.208

75. 72 16-29 77.439 78.198 72.916 76.936 73.837 21-25 72.888 62.956 70.911 70.008 71.654 26-39 72.614 75.191 70.475 70.928 71.864 31-35 70.532 70.879 70.563 70.7G3 70.539 36-48 71.292 71.070 15.956 16.644 14.881 41-45 17.452 14.338 16.397 14.395 16.943 46-58 14.617 16.694 13.796 13.583 14.056 51-52 14.348 14.211 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3330 29.3090 19.3140 45.824

.000

.000 59-61 44.114 16.6;5

.000 READING #163 AT 1: 7:33 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.461 74.425 74.665 73.75G 6-19 71.640 72.182 72.866 74.093 60.377 11-15 81.221 80.009 82.340 77.069 75.670 16-29 77.486 78.291 72.963 76.938 73.923 21-25 72.868 62.910 70.864 70.05~

7;.793 26-38 72.614 75.237 70.475 70.861 71.725 31-35 70.579 70.879 70.563 70.815 70.446 36-48 71.246 71.023 16.030 16.492 15.001 41-45 17.709 14.416 16.567 44.427 15.833 46-58 14.649 17.002 13.669 13.611

4.

34 51-52 14.289 14.289 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3310 29.3080 29.3110 45.757

.000

.000 59-61 3

44.024 16.6i0

.000 READING #164 AT 1:22:34 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.368 74.425 74.619 73.804 l

6-10 71.866 72.182 72.915 74.093 80.238 11-15 81.035 79.916 82.757 77.208 75.62G 16-29 77.439 76.198 72.963 76.938 73.883 R1-25 72.934 62.910 70.911 70.054 71.839 26-30 72.660 75.330 70.475 70.974 71.447 31-35 70.573 72.879 70.563 70.815 70.400 36-48 71.246 71.070 15.828 16.291 14.941 41-45

  • 7.737 14.397 16.733 14.409 17.375 46-Se 14.631 17.442-13.897 13.592 14.;1C 51-52 14.316 14.271 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3310 29.3060 29.3110 45.666

.000

.000 59-61 43.963 16.714

.000

_ INSTRUMENT C A L I_ B R A T E D DATA PAGE 4e READING #165 AT 1:37:35 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.663 74.415 74.379 74.665 73.756 6-19 71.793 72.182 72.868 74.139

80. 284 11-15 81.035 79.869 82.665 77.162 75.765 16-28 77.439 78.152 72.916 76.9'38 73.883 21-25 72.888 62.864 70.864 70.008 71.747 26-34 72.660 75.284 70.475 71.067 71.493 31-35 70.532 70.879 70.563 70.815 70.446 36-40 71.246 71.023 15.919 16.382 14.845 41-45 17.370 14.352 16.870 14.404 17.508

+6-58 14.672 16.845 13.805 13.592 14.116 51-52 14.408 14.225 i

PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3310 29.3070 29.3100 45.747

.000

.000!

59-61 43.902 16.583

.000 READING #166 AT 1:52:36 11/26/87 POINTS:

TEMPERATURE (FAHREEHEIT) 1-5 69.756 74.415 74.425 74.712 73.804 6-19 71.640 72.228 72.915 74.093 80.284 11-15 80.849 79.962 82.711 77.393 75.672 16-29 77.532 78.291 72.963 76.984 73.883 21-25 72.380 63.003 70.957 70.054 71.747 26-38 72.660 75.330 70.568 70.926 71.725 31-35 70.672 70.925 70.563 70.815 70.446 36-48 71.292 71.116 16.140 16.511 14.927 41-45 17.223 14.388 16.723 14.491 16.907 46-50 14.708 16.699 13.868 13.675 14.106 51-52 14.490 14.307 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-54 29.3310 29.3060 29.3100 45.698

.000

.000 59-61 43.844 16.606

.000 READING #167 AT as 7:37 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.368 74.425 74.619 73.804 6-18 71.840 72.226 72.915 74.093 60.238 11-15 81.174 79.916 82.525 77.347 75.672 16-29 77.486 78.337 73.009 76.938 73.929 21-25 72.980 62.956 70.911 70.101 71.793 26-38 72.660 75.284 70.475 70.881 71.771 31-35 70.532 70.925 70.517 70.861 70.539 36-48 71.246 71.116 16.149 16.199 14.941 41-45 17.324 14.397 16.503 14.454 16.595 46-58 14.722 16.754 13.851 13.638 14.116 51-52 14.454 14.271 PRESSURE (PSIA)

DEW POINT TEl@ERATURE 53-55,56-58 29.3300 29.3060 29.3110 45.680

.000

.000 59-61 43.772 16.799

.000

INSTRUMENT C A L_ I B R A T E Q__D A T E PAGE 45 READING #168 AT 2:22:38 11/26/87 l

POINTS:

TEMPERATURE (FAHRENHEIT) l 1-5 69.756 74.415 74.425 74.712 73.8c4 6-18 71.840 72.228 72.915 74.093 80.284 11-15 81.360 80.055 82.293 77.347 75.719 16-29 77.532 73.384 72.963 76.9'84 73.'376 21-25 73.027 63.003 70.957 70.147 71.793 26-30 72.707 75.234 70.568 70.881 71.632 31-35 70.625 70.879 70.517 70.815 70.539 36-48 71.246 71.116 16.066 16.662 15.037 41-45 17.425 14.448 16.512 14.505 16.512 46-59 14.773 16.579 13.814 13.647 14.125 51-52 14.504 14.372 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3320 29.3090 29.3140 45.626

.000

.020 59-61 43.704 16.6;9

.000 READING #169 AT 2:37:41 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.415 74.425 74.665 73.804 6-18 71.566 72.182 72.96; 74.;39 60.377 11-15 81.;28 80.055 82.572 77.208 75.719 16-29 77.466 78.337 72.963 76.984 73.883 21-25 72.330 63.003 71.003 70.10-7;.793 26-38 72.707 75.330 70.522 70.928 71.864 31-35 70.625 70.879 70.563 70.815 7C.492 36-48 71.232 71.116

  • C.094 17.240 15.065 41-45 17.406 14.480 16.402 14.532 16.861 46-58 14.754 16.469 23.842 13.721 14.106 51-52 14.490 14.353 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3310 29.3070 29.3110 45.289

.000

.000 59-61 43.655 16.664

.000 READING #170 AT 2:52:42 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.415 74.379 74.712 73.804 6-18 71.886 72.228 72.915 74.139 80.238 11-15 81.081 80.009 82.711 77.301 75.719 16-29 77.486 76.337 72.963 76.938 73.929 1

21-25 72.980 62.910 70.91; 70.054 71.747 26-38 72.660 75.423 70.522 70.835 71.679 31-35 70.532 70.786 70.517 70.768 70.400 36-49 71.200 71.070 16.122 17.497 15.138 i

41-45 17.296 14.462 16.521 14.473 16.934 46-50 14.741 16.634 13.824 13.702 14.088 51-52 14.518 14.335 1

PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-54 29.3310 29.3050 29.3100 45.239

.000

.000 59-61 43.574 16.650

.000 1

INSTRUMENT C A L_ I B R A T E D DATA PAGE 4

READING #171 AT 3: 7:43 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.415 74.379 74.712 72.711 6-10 71.793 72.136 72.868 74.093 80.284 11-15 80.803 79.916 82.293 77.208 75.579 16-20 77.439 78.291 72.916 76.691 73.837 21-25 72.934 62.910 70.911 70.054 71.700 26-38 72.660 75.376 70.522 71.067 71.447 31-35 70.579 70.879 70.563 70.815 70.539 36-48 71.292 71.116 16.002 18.020 15.202 41-45 18.003 14.460 16.815 14.445 17.270 46-58 14.754 16.653 13.888 13.721 14.136 51-52 14.536 14.353 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3330 29.3070 29.3110 45.415

.000

.000 59-61 43.498 16.556

.000 READING #172 AT 3:22:44 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.415 74.425 74.665 73.604 6-19 71.686 72.228 72.915 74.093 80.423 11-15 81.035 80.009 62.525 77.301 75.719 16-29 77.486 78.337 73.009 76.891 73.929 21-25 72.980 62.956 70.957 70.101 71.793 26-38 72.753 75.376 70.522 71.067 71.679 31-35 70.625 70.879 70.563 70.815 70.492.

)

36-46 71.246 71.116 15.965 17.754 15.170 41-45 18.654 14.535 16.641 14.546 17.421 46-56 14.814 16.800 13.943 13.730 14.070 51-52 14.500 14.362 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3320 23.3060 29.3110 45.334

.000

.000i 59-61 43.434 16.669

.000 READING #173 AT 3:37:45 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.663 74.368 74.379 74.619 73.711 6-19 71.840 72.136 72.822 74.046 80.284 11-15 81.081 79.962 82.293 77.115 75.626 16-29 77.439 78.291 72.916 76.891 73.883 21-25 72.842 62.310 70.864 70.008 71.747 26-38 72.660 75.237 70.522 71.067 71.632 31-35 70.579 70.833 70.517 70.768 70.539 36-4e 71.246 71.023 15.910 17.149 15.202 41-45 17.682 14.434 16.356 14.491 16.861 46-58 14.754 16.974 13.934 13.675 14.060 51-52 14.490 14.307 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3310 29.3040 29.3080 45.261

.000

.000 59-61 43.385 16.804

.000

I N S T R LJME N T C A L_ I B R A T E D DATA PAGE 47 READING #174 AT 3:52:47 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.554 74.518 74.604 73.897 6-19 71.979 72.321 72.961 74.185 60.470 11-15 80.895 80.102 82.386 77.440 75.951 16-20 77.625 78.291 73.055 76.984 73.976 21-25 72.980 63.003 70.957 70.101 71.839 26-39 72.846 75.469 70.522 71.067 71.632 31-35 70.672 70.925 70.656 70.861 70.585 36-40 71.339 71.116 16.076 17.406 15.276 41-45 17.388 14.599 16.567 14.610 16.751 46-50 14.924 17.185 14.053 13.794 14.226 51-52 14.610 14.427 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3300 29.3050 29.3090 45.239

.000

.000 59-61 43.317 16.750

.000 READING #175 AT 4: 7:48 11/26/87 POINTS:

TEMPERATURE (FAHRE HEIT) 1-5 69.736 74.554 74.472 74.804 73.897 6-19 72.025 72.321 73.007 74.185 80.516 11-15 81.428 80.102 82.525 77.206 75.997 16-29 77.578 78.337 73.055 77.077 74.022 21-25 72.934 63.049 70.957 70.147 71.886 26-38 72.846 75.469 70.614 71.159 71.679 31-35 70.672 70.971 70.609 70.861 70.492 36-48 71.292 71.116 16.076 17.222 15.276 41-45 17.480 14.645 16.705 14.610 16.659 46-58 14.924 17.002 14.093 13.840 14.271 51-52 14.610 14.473 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3320 29.3050 29.3110 45.104

.000

.300 59-61 43.268 16.678

.000 READING #176 AT 4:22:50 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.554 74.518 74.851 73.850 6-10 72.025 72.321 73.007 74.139 80.516 11-15 81.281 80.102 82.386 77.347 75.951 16-29 77.578 78.291 73.055 76.938 73.976 21-25 72.934 62.910 70.911 70.054

71. 7'd3 26-38 72.799 75.423 70.568 70.974 71.493 31-35 70.579 70.925 70.563 70.815 70.492 36-48 71.246 71.070 16.030 16.860 15.260 41-45 17.984 14.599 17.118 14.610 16.705 i

46-58 14.924 16.818 14.099 13.845 14.226 51-52 14.610 14.427 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-5a 29.3270 29.3020 29.3070 45.054

.000

.000 59-61 43.223 16.714

.000 l

I N S T R LA ME N T C A L_ I B R A T E D DATA PAGE 4

READING #177 AT 4:37:51 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.554 74.472 74.804 73.897 6-18 72.025 72.367 72.961 74.185 80.331 11-15 81.035 80.055 82.757 77.347 76.030 16-29 77.578 78.337 73.102 76.984 73.976 21-25 72.980 63.003 70.864 70.101 71'839 26-38 72.846 75.515 70.568 71.159 71.586 31-35 70.625 70.925 70.563 70.815 70.492 36-48 71.200 71.023 16.076 16.722 15.276 41-45 16.030

4.645 17.302 14.656 16.567 l

46-50 14.965 16.680 14.099 13.840 14.226 51-52 14.610 14.473 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3290 29.3020 29.3070 45.010

.000

.00G.

59-61 43.155 16.826

.000 READING #178 AT 4:52:53 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.554 74.472 74.804 73.897 6-18 71.E79 72.367 73.054 74.139 80.377 11-15 81.281 80.003 82.850 77.347 76.090 16-28 77.578 78.384 73.055 77.030 73.976 21-25 72.980 63.003 70.911 70.054 71.793 26-38 72.846 75.469 70.614 71.159 71.632 a

31-35 70.625 70.925 70.563 70.815 70.539 36-48 71.153 71.070 16.066 16.621 15.221 41-45 17.654 14.590 17.43; 14.647 16.466 46-56 24.915

6.533 14.044 13.831 14.171 51-52 14.555 14.463 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3250 29.3010 29.3050 45.010

.000

.000 59-61 43.102 16.754

.000 READING #179 AT 5: 7:54 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.600 74.472 74.804 73.897 6-le 72.025 72.367 73.054 74.139 80.423 11-15 81.313 80.102 82.757 77.208 76.043 i

16-28 77.625 78.384 73.102 77.030 74.069 21-25 72.980 63.095 70.864 70.101 71.839 26-38 72.892 75.469 70.614 71.113 71.586 31-35 70.672 71.018 70.563 70.815 70.492 36-48 7".246 71.116 16.213 16.534 15.322 41-45 17.526 14.686 17.114 14.697 16.838 46-58 14.965 16.542 14.099 13.886 14.271 51-52 14.651 14.514 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3300 29.3060 29.3100 44.919

.000

.000l 59-61 43.075 16.754

.000

I N S T R LJMEE N T C A L_ I B R A TE Q_,_D A T A PAGE 49 READING #180 AT 5:22:55 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 63.756 74.554 74.472 74.712 71.650 6-18 71.979 72.4;4 72.915 73.907 80.33a 11-15 81.235 60.009 82.665 77.254 75.997 16-29 77.620 78.384 72.824 76.891 73.976 21-25 72.380 62.864 70.957 70.147 71.839 26-30 72.G92 75.145 70.661 70.835 7;.493 31-35 70.672 70.971 70.563 70.815 70.%46 36-40 71.246 71.023 46.177 16.410 15.285 41-45 17.306 14.654 16.806 14.706 17.035 46-59 14.928 16.598 14.108 13.895 14.235 51-52

  • .665 14.528 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 23.3250 23.3050 29.3100 45.045

.000

.300 59-61 43.086

'6.76;

.000 READING #181 AT 5:37:56 11/26/87 POINTS:

TEMPERATURE (FAHRE HEIT) 1-5 69.756 74.507 74.516 74.804 73.337 6-10 7..L32 72.367 72.915 73.86; 80.423 11-15 80.535 82.102 82.757 77.254 75.904 16-29 77.625 76.337 72.776 76.845 73.376 21-25 72.:34 62.356 70.91-70.194 7.

733 26-30 72.632 75.284 70.66 71.067 71.77; 31-35 70.7:6 70.325 70.563 70.615 70.400 36-48 71.246 71.070

6.065

'6.316 15.265 41-45 17.306 14.654

6.852 14.706 16.852 46-58 14.374
G.627
4.062 13.G35

.4.26; 51-52 14.665 4.573 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 23.3230 23.3040 23.3090 44.688

.000

.000 59-61 45.037 16.761

.000 READING #182 AT 5:52:58 11/26/87 POINTS:

TEMPERATURE (F4HRENHEIT) 1-5 69.756 74.*64 74.472 74.758 73.852 6-19 71.332 72.321 70.315 73.763 60.23G 11-15 80.342 80.194 62.804 77.161 76.0*3 16-29 77.625

76. 36 72.731 76.752 73.376 j

21-25 72.366 63.003 72.91; 70.194 71.833 26-38 72.646 75.191 72.614 71.067 71.77; 31-35 74.672 70.a79 70.517 70.768 70.4*6 36-40

7. 246 71.023
6.085 16.456 15.265 41-45 17.260 14.700 16.622 14.706 16.7;*

46-50 4.374

6. 9 ' 3 14.062 13.895 14.281 51-52 14.665 14.523 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3230 23.3060 29.31.0 44.81.

.000

.000 l

59-61

-2.962 16.869

.000

I 1

l JNSTRUMENT C A L I E: R A TE D DATA PAGE I5 READING #183 AT 6: 6: 0 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 63.756 74.4;5 74.415 74.711

~.~. 6 0 4 6-10 7;.332 72.226 71.3; 70.S_L 3 ?. /-C 3 11-15 62.835 60.055 62.804 77..c~

...ows 16-20 77.532 78.136 71.61*

76.'s35

73. 323 21-25 72.688 63.043 70.311 70.101 7.

700 26-30 72.346 75.13 72.707 7;.067 7.

433 31-35 70.625 70.3E5 70.563 70.768 70.431 36-40 71.232 71.1;6

6.002 16.603 15.23-41-45 17.361 14.663

.6.632 14.715 li.03; 46-50 14.383 16.881 14.025 13.304 14.244 51-52 14.628 14.431 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 23.3230 23.3050 23.3080 44.68;

.030

.0@

59-61 42.306 16.862

. 004 READING #184 AT 6:23: 1 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 63.756 74.600 74.518 74.837 73.343 6-10 72.072 72.367 73.054 74.033 80.331 11-15 81.128 80.102 82.837 77.023 76.043 16-20 77.671 78.231 73.055 77.030 73.376 21-25 72.330 63.035 70.3..

70.147 7;.733 26-30 72.385 75.423 70.614 71.002 7;.310 31-35 70.625 70.371 70.603 73.86; 72.431 36-40 71.333 71.1;6

6. a e3

_7.

12

.5.343 41-45 17.461 14.714

16. 67.0 14.7C5

.6.63G 46-50 15.038 16.743

4. 22
3.35!
4.134 51-52 14.678 1*.54 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 23.323e 23.3040 23.3030 44.630

.000

.00C 59-61 42.830

.E.620

. iI; READING #185 AT 6:38: 2 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 63.703 74.556 74.47d 74.804 72.650 6-10 71.332 72.228 70.207 74.046 52.I64 11-15 8;.221 80.035 61.350 77.165 76.043 16-20 77.578 75.231 71.363 76.331 73.313 21-25 72.686 63.03; 70.66*

70.254 74.747 26-30 72.336 75.264 72.566 71.153 7;.366 31-35 70.625 72.371 70.563 70.768 70.*32 36-40 7.

146 71.070

6.034 17.332 15.134 41-45 17.3'5 4.703 16.540 14.715 16.53; 46-50
4.36
6.65a

.*.071 13.324 14.230 51-52 14.628 14.537 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 23.3260 23.3020 23.3060 44.6*C

.e00

.020 53-61 41.667

.6.634

.007

INETRUMENT C A L I QR A T EEE D DATA P A G EE 51 READING #186 AT 6:53: 4 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 63.E6L 74.507 74.423 74.60e 72.3:4 6-10

.. :r e c

<c.cce 7;.30, 74.046 Ge.32.

11-15

a. 9Be.

os.se3 oz.c.--o

,,.een

, s..uc 16-20 7,1 saa 7 u... :m a _. a ss

w.,. a u

,a...c2 c-21-25 74.e41 62.043 70.771 70.006 7;.747 l

26-30 74.J.s; 75.I64 72,.429 70.928 7 _. 4 2. :.

l 31-35 7t.rJ; "J. 3 /.

70.517 70.676 70.203 l

36-40 7. 53 72.377

-.6.131 16.635

.5.301 41-45

.7 ~2I

4. 636

.6.460 14.661

. 6.. I 46-50

. *. 0 76 16.73.

24.103 13.895 U. ;; '

51-52

.e.6:"

16.477 PRESSURE (PSIA)

DEW DOINT TEMPERATURE 53-55,56-58

25. 37.G2 23.104c 29.007d 44.F,

. O s0

. 000 59-61

  • c.u

. 6.., s.. -

.wtv READING #187 AT 7: 8: 5 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 63.153 74.

. C 74.379 74.6;9 72.6 4 6-10 71.

-0 7d. 61 71.621 73.6;C 52.12G 11-15 6..

5 60.<SO G2.330 77.065 75.3B4 4

16-d0

-. :s ar.==<

i c.. u 1 o.

,u..ss aa.=as r

21-25 71.

20 G2.203 7J.772 63.961

'. 13e 26-M r e.. c - c 7 s,. 3.<w

,,v.sec.

. e,. o. _ _es

... s_.,

v 31-35 70.531 72.673 70.426 70.676 72.253 36-40

. w..s..

s.

22

.u.*.2

.,c,

...ne.

41-45

.<. o 7 c.

. n., 5,2

,e.s...ue 2

.co.

_.cou 46-50 14.97-7.007 4.0.5

.;.6a3

.~.12:

4 51-52

.4.-6.

.e.010 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 Z?.3262 23.3000 23.3260 44.616

.000

.000 59-61

  • 2."64

.G.663

.0:e READING #188 AT 7:23: 6 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 63.756 7.600 74.!G*

74.631 70.637 6-10 e... n - -u<r

<c.sc.

.e,,s*

,4. 0 *..u 6 s..-ca

<s 11-15 S0.342 G0.;00 GO.350 77.005 76.030 16-20 n..,

7 v... c. *,

.2

.tc

<u.o.c

..c c-21-25 y.

.w.

36 s~

o-..

, e. _s a,,

r

,c.

t*<

7

.us2

~

26-30 72.565 75.5.5 70.614 71.067 7;.~71 31-35 72.572 7.

06-70.563 70.661 70.539 36-40

7.. 4 E 71.072 26.149 16.337 15.2a3 41-45 17.300 14.652 16.870 14.816 17.532 i

46-50

.5.464 17.621

.4.218 13.959 14.427 51-52 14.676

.4.633 J

PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 19.3C32 19.3230 19.3072 44.636

.000

.000 59-61 42.701

.6.656

.000 I

i

I N E T R LJ fvtE N T CAL I BR ATED DATA AAGE 25 READING #189 AT 7:38: 7 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.554 74.515 74.651 72.C97 6-10 71.979 72.228 73.054 74.093 60.516 11-15 81.060 80.148 GI.990 77.206 76.043 16-29 77.625 76.245 73.055 76.845 74.022 21-25 72.534 63.141 70.864 70.101 71.633 26-30 72.985 75.237 70.568 71.113 7".540 31-35 70.079 71.016 70.609 70.815 70.446 36-48 71.246 71.070 1G.085 16.777 15.277 41-45

7.469 14.638 17.082 14.798 17.226 46-58 15.158 16.965 14.200 14.033 14.372 51-52

>4.756 1*.6.9 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3250 25.2930 23.3050 44.466

.000

.20a 59-61 42.C55

_G.062

.c00 READING #190 AT 7:53: 9 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 65.709 74.554 74.472 74.65.

72.530 6-19 71.COC 72.226 72.561 74.033 O!.077 11-15 00.;38 60.146 82.650 77.200 70.35.

16-28 77.578 78.198 72.963 76.79a 73.376 21-25 72.338 63.043 70.864 7.7. 0 5 4 7.

733 26-38 72.565 75.469 70.522 71.

10 7;.566 31-35 70.579 70.97; 70.563 70.768 70.446 36-48 71.200 70.977 16.253

7.360

.5.022 41-45 17.205

4.829 16.705 14.748 16.334' 46-58 15.057 16.726 14.;45 14.023 14.27.

51-52 4.747 14.656 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 23.3270 29.3020 29.3070 44.514

.000

.000:

59-61 42.615

7.006

.000 I READING #191 AT 8: 8:19 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.802 74.600 74.611 74.897 74.036 6-le 71.979 71.367 72.100 74.185 80.423 11-15 80.942 80.255 82.757 77.347 76.136 16-28 77.625 78.337 73.146 76.631 74."15 21-25 72.900 63.141 70.957 70.;47 71.639 26-30 73.031 75.515 70.614 71.113 7".401 31-35 70.7.8 71.064 70.609 70.815 70.539 36-4e 71.292 71.116 16.379 17.204 15.487 41-45 17.416 14.852 16.457 14.862 16.732 46-5e 15.130 16.937 14.218 14.051 14.045 51-52 14.816 14.679 i

PRESSURE (PSIA)

DEW POINT TEMPERATURE j

53-55,56-58 29.3270 25.3020 29.3070 44.483

.000

.000l

)

59-61 42.575

6.876

.000

l l

INSTRUMENT C A L_ I B_ pQTSE_QA T A PAGE 53 READING #192 AT 8:23:12 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 63.756 74.600 74.564 74.851 73.343 6-10 71.979 72.367 73.054 74.165 80.516 11-15 61.035 80.134 62.804 77.347

76. 36 16-20 77.625 78.291 73.148 76.3a4 74.069 21-25 73.027 63.095 70.911 70.147 71.6G6 26-30 73.031 75.463 70.522 71.391 71.493 31-35 72.672 71.018 70.563 70.815 70.446 36-40 71.246 71.023 16.388 17.213 15.450 41-45

.7.562 14.86a 16.466 14.871 16.636 f

46-50 15.165 16.717 14.227 14.060 14.334 51-52

4. 773 14.642 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3260 23.3010 29.3060 44.283

.000

.000 59-61 42.521 16.876

.027 READING #193.AT 8:38: 13, 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 63.223 74.507 74.472 74.804 73.837 6-10 71.006 72.225 75.007 74.;33 62.33.

11-15

81. Ca 80.102 82.943 77.254 75.337 16-29 77.J'8 76.152 73.0!!

76.935 73.323 21-25 72.334 63.035 70.772 7C.054 71.747 26-30 72.938 75.264 70.475 70.861 71.406 31-35 70.579 70.325 70.563 70.722 70.400 36-48 71.200 70.377 16.357 17.064 15.433 j

41-45 17.526

4.778 16.52; 14.783 16.376 l

46-58 15.;03 16.634 14.130 13.376

.*.271 l

51-52 14.743 14.560 1

PRESSURE (PSIA)

DEW POINT TEMPERATURE

{

53-55,56-58 29.3240 29.2390 23.3040 44.228

.200

.000 l

l 59-61 42.503 16.849

.220 l

READING M194 HT 8:53:14 11/26/87 l

l POINTS:

TEMPERATURE (FAHRENHEIT)

I 1-5 63.756 74.670 74.518 74.837 73.343 6-10 72.025 72.367 73.054 74.232 62.423 11-15 S0.603 80.148 82.757 77.347 76.;36 16-29 77.67; 78.337 73.148 76.938 74.063 1

21-25 72.380 63.141 70.311 70.101 7;.839

{

26-30 73.031 75.423 70.522 70.974 71.673

(

31-35 70.625 71.018 70.563 70.815 70.446 36-48 71.292 71.072 16.351 17.176 15.537 41-45

7.647 14.316 16.838 14.835 17.153 46-50 15.494 16.853 14.323 14.115 14.353 51-52 14.788 14.651 PRESSURE (PSIA)

DEW POINT TEPRERATURE 53-55,56-58 29.3260 29.3000 29.3050 44.240

.000

.000 59-61 42.426 16.637

.000

INETRUMENT C AL I BR ATED DATA PAGE "5

READING #195 AT 9

8:15 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.600 74.554 74.897

73. 39I 6-19 71.979 72.367 73.100 74.232 GC.470 11-15 81.128 80.24; 82.850 77.347
72. 36 16-29 77.671 78.337 73.194 77.030 74.

15 21-25 73.027 63.188 70.911 70.147 7;.33I 26-39 73.377 75.562 70.568 71.020 71.493 31-35 70.672 71.064 70.656 70.861 70.539 36-49 7;.339 71.

16 16.360 17.690 15.789 41-45 18.26S 14.925 16.939 14.889 17.444 46-59 15.249 16.823 14.241 14.170 14.322 51-52

4.843 14.752 PRESSURE (PSIA)

DEW POINT TEMPERATURE

~

i 53-55,56-58 29.3250 29.3030 29.3080 44.;39

.000

.200l 59-61 42.366 15.C39

.000 READING #19G AT 9:23:1,6 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.554 74.516 74.G97 73.943 6-19 71.932' 72.32; 73.054 74.;8 60.363 11-15 81.035 80.148 82.804 77.30.

76.250 16-25) 77.671 78.337 73.102 76.936 74.259 21-20 72.580 63.295 70.664 70.101 7.

339 26-38 73.077 75.423 70.568 71.067 7;.493 31-35 70.625 7;.018 70.563 70.768 70.492 36-48 71.246 71.023

6.362
7.598

.5.743 41-45 18.68:

14.929 16.714

.e.889

.7.536 46-58 15.203 16.965

4.291 4.;24
4.327 51-52 14.798 14.71

PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3250 29.2990 29.3050

44. ISO

.300

.400' 59-61 42.328 14.734

.000 READING #197 AT 9:38:17 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.534 74.5;6 74.85; 73.943 6-19 71.932 72.321 73.054 74.139 80.423 11-15 81.081 80.148 82.618 77.208 76.043 16-29 77.578 78.245 73.102 76.891 74.022 21-25 72.934 63.095 70.818 70.054 71.839 26-39 73.031 75.376 70.614 71.020 71.679 31-35 70.625 71.064 70.609 70.815 70.492 36-49 71.246 71.070 16.278 17.194 15.6*5 41-45 17.773 14.888 16.540 14.853 16.999 46-58 15.167 17.245 14.255 14.133 14.290 51-52 14.76; i4,674 PRESSURE (PSIA)

DEW POINT TEt@ERATURE 53-55,56-58 29.3230 29.2990 29.3030 44.073

.300

.000 59-61 42.278 15.616

.000

I N S T R UtvtE N T C A L_ I B R A T E D D A T G),

P fub G E 55 READING #198 AT 9:53:19 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 65.709 74.600 74.518 74.6 1 73.637 6-18 71.G86 72.275 73.054 74.133 60.331 11-15

61. 2e 80.102 83.222 7 7. 2,5 4 76.043 16-29 77.576 78.152 73.102 76.736 74.022 21-25 72.688 63.035 70.818 70.006 71.733 26-30 73.03.

75.423 70.522 71.020 71.771 31-35 70.579 71.018 70.517 70.768 70.445 36-49 71.200 71.023 16.223 17.323 15.560 41-45

.7.357 14.329

'6.531 14.844 16.7t4 46-50 15.203 17.194 14.245 14.078 14.327 51-52 4.796 14.665 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3240 23.3010 29.3000 44.114

.000

.000 59-61 e2.256 16.502

.070 READING #199 AT 10: 8:21 11/26/87 POINTS:

TEMPERATURE (FAHRE$HEIT) 1-5 69.709 74.600 74.518 74.944 73.330 6-19 71.332 72.;21 72.100 74.;GS G0. 33.

11-15 80.368 60.055 82.343 77.226 76.030 16-29 77.625 78.198 73.102 76.843 74.069 21-25 72.560 63.095 70.864 70.;01 71.866 26-38 73.077 75.330 70.568 71.02?

71.540 31-35 70.623 71.018 70.517 70.768 70.4*6 36-48 71.200 71.023 16.287

.7. 020

.5.532 41-45 17.416 14.837 16.687 14.862 16.G86 46-58

5.268 17.029 14.218
4.;43 14.233 51-52 14.616 14.673 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3210 23.2370 29.3020 44.078

.000

.000 59-61 42.206

.6.347

.000 READING #200 AT 10:23:22 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 63.802 74.600 74.564 74.897 73.343 6-19 71.332 72.275 73.054 74.165 60.423 11-15 80.942 80.102 83.222 77.115 76.090 16-29 77.625 76.198 73.102 76.752 74.022 21-25 72.960 63.141 70.911 70.147 71.333 26-38 73.031 75.562 70.614 71.298 71.433 31-35 70.625 71.110 70.563 70.815 70.492 36-40 71.292 71.070 16.369 16.736 15.563 1

41-45 18.04G 14.934 17.224 14.899 16.763 46-50 15.258 16.882 14.300 14.179 14.362 51-52 14.853 14.720 i

PRESSURE (PSIA)

DEW POINT TEMPERATURE

)

53-55,56-58 29.3210 29.2980 29.3030 43.343

.000

.000 59-61 42.188 16.373

.200 l

INSTRUMENT C A L-X B R A?fE.Q_.._D A T A PAGE SC READING #201 AT 10:38:24 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.802 74.646 74.657 74.990 74.036 6-10 71.979 72.414 73.147 74.232 80.470 11-15 81.406 80.;94 CE.943

77. 3t 7 7G.iB2 16-29 77.718 78.211 73.194 76.93G 74.069 21-25 73.027 63.188 70.957 70.147 71.978 26-38 73.124 75.469 70.568 71.252 71.540 31-35 70.672 71.064 70.609 70.861 70.492 36-48 73.292 71.162 16.282 16.653 15.624 41-45 18.099 14.989 17.463 14.999 16.682 46-50 15.313 16.841 14.397 14.230 14.386 51-52 14.906 14.8;6

]

PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3240 29.2990 29.3030 46.020

.000

.000 59-61 42.

16

.6.979

.000 READING #202 AT 10:55: 0 11/26/87

~

POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.729 74.600 74.564 74.851 73.990 6-19 71.932 72.367 73.054 74.

65 60.*70 11-15 81.128 80.102 82.711 77.254 76.090 16-29 77.625 78.245 73.102 76.691 74.069 21-25 72.350 63.141 70.86*

72.147 7;.339 26-38 73.077 75.376 70.514 71.159 71.586 31-35 70.625 71.064 70.563 70.845 70.442 36-48 71.246 71.023 16.342 16.616 15.542 41-45 17.654 14.998 17.518 14.963 16.604 46-58 15.277 16.62:

14.360 14.198

4.354 51-52 14.871
14..~34 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3230 29.2990 29.3040 44.130

.000

.00?

59-61 42.066 17.025

.020 READING #203 AT 11:10: 2 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.554 74.564 74.85; 73.990 6-19 71.866 72.275 73.004 74.

39 80.423 11-15 80.942 80.146 82.665 77.301 76.162 16-29 77.578 78.152 73.102 76.545 74.069 d

21-25 72.934 63.095 70.864 70.054 71.932 26-38 73.077 75.423 70.522 71.225 71.08E 31-35 70.625 71.064 70.517 70.815 70.492 36-48 71.200 71.070 16.480 16.479 15.542 41-45 17.471 14.952 17.059 14.963 16.675 46-58 15.277 16.625 14.360 14.198 14.400 51-52 14.871 14.780 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3240 29.2990 29.3020 43.340

.000

.000 59-61 41.044 17.123

.000

INSTRUMENT C3 A LdB R A T E_Q_._,D A T A P AG EE 5 '7 READING #204 AT 11:25: 4 11/26/87 i

POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.600 74.564 74.897 72.930 6-10 71.932 72.32*

73.054 74.139 60.423 11-15 81.128 80.102 82.757 77.393

76. 36 16-29 77.578 78.152 73.102 76.798 74.022 21-25 72.980 63.141 70.818 70.101 71.886 26-39 73.077 75.284 70.568 70.974 7;.493 31-35 70.579 71.018 70.563 70.815 70.446 36-40 71.246 71.023 16.305 16.350 15.50.

41-45 17.342 15.007 16.884 14.972 17.

13 46-59 15.286

6.634 14.323 14.207 14.404 51-52 14.880 14.835 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.0200 29.2950 29.2990 43.952

.000

.000 59-61 41.977 17.i77

.004 READING #205 AT 11:40:36 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.600 74.564 74.944 73.992 6-18 71.132 72.367 73.100

74. :8 BJ.47I 11-15 80.942 80.102 82.757 77.254 76.043 16-29 77.5?8 78.152 73.;02 76.752 74.069 21-25 73.027 63.188 70.864 70.12; 71.932 26-38 73.124 75.423 70.614 71.1;3 71.493 31-35 70.625 71.018 70.563 70.768 70.400 36-48 71.200 71.023 16.287
6.337
5.532 41-45 17.324 14.989 16.870 14.999 16.872 46-50
5.268 16.937 14.310 1*.224 4.39.

51-52 14.862 14.862 1

i PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3200 29.2960 29.3000 43.785

.000

.000 59-61 41.972 17.3+<

. v4 r i

READING 4286 AT 11:55:37 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.554 74.472 74.897 73.397 6-10 71.886 72.275 73.054 74.139 80.470 11-15 81.128 80.055 82.665 77.206 75.397 16-29 77.578 77.920 73.055 76.706 74.022 21-25 72.888 63.14; 70.864 70.054 71.839 26-38 73.031 75.423 70.522 71.113 71.447 31-35 70.579 71.018 70.517 70.722 70.353 i

36-40 71.153 70.977 16.278 16.465 15.569 41-45 17.361 14.985 16.586 14.949 16.677 j

46-54 15.309 17.020 14.300 14.179 14.382 51-52 14.903 14.812 i

PRESSURE (PSIA)

DEW POINT TEMPERATURE l

53-55,56-58 29.71170 29.2940 29.2980 43.727

.000

.000 l

59-61 41.882

.7.092

.000 l

4 l

. l l

I N S T RLJME N T CAL I BR ATED DATA PAGE Ss READING #297 AT 12:19:38 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.554 74.564 74.9??

73.990 6-19 71.932 72.414 73.100 74.185 80.331 11-15 80.988 80.194 82.804 77.301 76.162 16-29 77.625 76.152 73.102 7 6. 8'9 1 74.069 21-25 72.980 63.234 70.911 70.194 71.686 26-39 73.124 75.469 70.614 71.113 71.493 31-35 70.672 71.110 70.563 70.768 70.492 36-49 71.200

/1.023 16.443 16.855 15.688 41-45 17.526 15.099 16.792 15.063 16.746 46-5e 15.378 16.997 14.369 14.299 14.496 51-52 14.972

4.881 PRESSURE (PSIA)

DEW POINT TEMPERATURE 9

53-55,56-58 29.3200 29.296C 29.3000 43.911

.000

.000 59-61 41.877

7.042

.000 g

READING 4298 AT 12:25:40 11/26/87 POINTS:

TEMPERATURE (FAHREhMEIT) 1-5 69.756 74.507 74.518 74.944 73.943 6-18 71.040 72.32; 73.054 74.139 80.264 11-15 80.595 80.101 82.386 77.162 76.043 16-29 77.578 78.059 73.055 76.845 74.069 21-25 72.034 63.188 70.911 70.147 7;.839 26-38 73.077 75.330 70.568 71.113 71.586 31-35 70.672 71.064 72.517 72.766 70.446 36-48 71.292 71.070 16.369 17.286 15.661 41-45 17.452 15.072 16.769 14.990 16.63.

46-58

'5.250 16.750 34.346 14.317

4.407 51-52 14.698 14.812 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 19.3190 29.2920 29.1982 43.763

.200

.000 59-61 41.837 16.986

.002 READING #209 AT 12:40:42 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.55' 74.564 74.944 73.943 6-18 71.932 72.367 73.054 74.139 80.413 11-15 80.942 80.148 82.665 77.254 76.043 16-29 77.532 78.059 73.102 76.752 74.069 t

I 21-25 72.980 63.141 70.818 70.101 71.839 26-38 73.031 75.284 70.568 70.928 71.586 31-35 70.625 71.064 70.517 70.722 70.492 36-49 71.200 7*.023 16.333 17.066 15.670 41-45 17.416 15.081 16.595 15.045 16.641 46-58 15.313 16.754 14.356 14.280 14.391 51-52 14.953 14.816 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3160 29.2910 29.2970 43.659

.000

.000 59-61 41.752 17.128

.000

I N S T R LJME N T C A L_ I B R A T E D D A *T A PAGE F5 9 READING #210 AT 12:55:43 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 G9.709

~74.507 74.564 74.944 73.39?

6-19 71.886 72.367 73.054 74.165 80.403 11-15 81.035 80.102 82.665 77.301 76.043 16-29 77.625 78.105 73.148 76.831 74.2G3 21-25 72.980 63.188 70.864 70.101 7*.066 26-39 73.077 75.376 70.568 71.020 71.40; 31-35 70.579 71.064 70.563 70.768 70.432 36-49 71.200 71.023 16.434 16.759 15.679 41-45 17.654 15.140 16.650 15.054 16.037 46-59 15.368 16.947 14.365 14.289 14.446 51-52

4.675 14.784 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3130 29.2890 29.2940 43.538

.002

.300 59-61 41.733

17. 41

.002-READING #211 AT 13: 5:41 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.507 74.518 74.944 73.990 6-19 71.932 72.367 73.100 74.;39 60.470 11-15 81.174 80.102 82.757 77.254 75.997 16-29 77.578 78.013 73.055 76.845 74.022 21-25 72.934 63.188 70.818 70.101 71.839 26-38 73.077 75.330 70.614 70.926 71.586 31-35 70.625 71.018 70.5*7 70.722 72.446 36-48 71.200 71.023 16.360 16.635 45.606 I

41-45 17.810 15.154 16.756 15.027

6.071 46-59 15.341 17.282 14.378 14.257
4.5t

51-52 14.843 14.793 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3140 29.2890 29.2940 43.624

.000

.000 59-61 41.711

17. 05

.000 READING #212 AT 13:15:42 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.554 74.518 74.944 73.990 6-19 71.932 72.367 73.100 74.139 80.470 11-15 80.895 80.148 82.665 77.347 76.043 16-29 77.625 78.013 73.148 76.845 74.069 21-25 72.934 63.141 70.864 70.147 71.839 26-38 73.124 75.423 70.614 71.067 71.493 31-35 70.625 71.064 70.517 70.722 70.492 36-49 71.200 70.977 16.342 16.479 15.542 41-45 17.975 15.136 16.967 15.054 16.604 46-59 15.368 17.355 14.360 14.289 14.487 51-52 14.825 14.780 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3150 29.2910 29.2940 43.479

.000

.000 59-61 41.693

7.;55

.000

l INSTRQMENT C A L_ I B R A TED DATA PAGE 6

READING #213 AT 13:25:43 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.663 74.507 74.518 74.897 73.343 6-18 71.086 72.321 73.100 74.139 S2.563 11-15 81.221 80.194 82.293 77 301 76.043 16-29 77.578 77.920 73.102 76.891 74.069 21-25 72.934 63.188 70.864 70.054 71.066 26-39 73.124 75.330 70.614 71.020 7*.447 31-35 70.579 71.110 70.470 70.722 70.446 36-48 71.107 70.977 16.305 16.304 15.551 41-45 17.847

5.145 16.976 15.063 17.048 46-58 15.378 17.594 14.415 14.299 14.496 51-52 14.9E6 14.789 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3110 19.2870 25.2920 43.650

.000

.200:

59-61 41.675 17.056

.020, READING #214 AT 13:35:43 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.554 74.564 74.944 73.990 6-18 71.086 72.367 73.100 74.139 60.471 11-15 81.3.3 80.148 82.757 77.301

76. 36 16-29 77.578 78.013 73.102 76.845 74.022 21-25 72.934 63.234 70.91.

70.101 71.932 26-38 73.077 75.284 70.661 71.067 71.679 31-35 70.625 71.064 70.470 70.721 70.446 36-48 71.153 70.977

6.314 16.543 15.560 41-45 17.581 15.108 17.077 15.073 17.720 46-58 15.433 17.190 14.424 14.303 14.505 51-52 14.981 14.844 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3140 29.2880 29.2930 43.578

.000

.000' 59-61 41.644 17.004

.000 READING #215 AT 13:45:43 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.554 74.611 74.990 74.036 6-19 71.932 72.414 73.147 74.185 80.470 11-15 80.895 80.194 82.850 77.301 76.090 16-29 77.625 78.152 73.148 76.938 74.069 21-25 73.027 63.188 70.957 70.147 71.886 26-38 73.124 75.330 70.661 71.113 71.586 31-35 70.672 71.157 70.517 70.768 70.446 36-44 71.246 71.070 16.383 17.488 15.633 41-45 17.333 15.182 17.105 15.100 17.518 46-54 15.414 16.942 14.406 14.422 14.487 51-52 15.008 14.917 PRESSURE (PSIA)

DEW POINT TEp6MERATURE 53-55,56-58 29.3130 29.2900 29.2940 43.610

.000

.000 59-61 41.616 17.083

.000

~

I N S T R LIME N T C A L_ I B R A T E D DATA PAGE 61 READING #216 AT 13:55:44 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.663 74.461 74.518 74.097 73.343 6-19 71.886 72.367 73.054 74.139 80.470 11-15 80.942 80.055 62.757 77 454 76.043 16-29 77.578 77.966 73.102 76.89; 74.069 21-25 72.980 63.188 70.864 70.147 71.839 26-38 73.077 75.237 70.614 71.067 71.447 31-35 70.579 71.064 70.517 70.768 70.400 36-49 71.153 70.977 16.484 17.635 15.592 i

41-45 17.159 15.145 16.700 15.063 16.836 46-58 15.423 16.859 14.369 14.340 14.450 l

51-52 14.972 14.835 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3130 29.2870 29.2930 43.534

.000

.000 59-61 41.565 17.110

.000 READING #217 AT 14: 5:44 11/26/87

~

POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.554 74.611 74.990 74.036 6-18 71.932 72.414 73.100 74.139 60.423 11-15 81.174 80.148 82.897 77.301 76.090 16-29 77.625 78.152 73.102 76.384 74.115 21-25 72.980 63.188 70.911 70.147 71.932 26-38 73.124 75.515 70.568 71.067 71.725 31-35 70.625 71.064 70.563 70.815 70.492 36-44 71.246 71.070 16.567 17.488 15.679 41-45 17.333 15.182 16.462 15.100 16.783 46-58 15.414 16.988 14.452 14.377 14.487 51-52 15.008 14.917 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-54 29.3120 29.2880 29.2920 43.372

.000

.000 59-61 41.549 17.249

.000 READING #218 AT 14:15:45 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.554 74.564 74.944 73.990 6-18 71.886 72.414 73.100 74.185 80.377 11-15 80.988 80.194 82.990 77.301 75.997 16-29 77.532 77.966 73.148 76.798 74.069 21-25 72.980 63.188 70.911 70.147 71.886 26-38 73.170 75.376 70.568 71.113 71.354 31-35 70.625 71.064 70.517 70.768 70.446 36-44 71.153 71.023 16.654 17.295 15.670 41-45 17.553 15.173 16.365 15.091 16.641 46-54 15.405 16.983 14.447 14.280 14.482 51-52 14.953 14.862 PRESSURE (PSIA)

DEW POINT TEMERATURE 53-55,56-54 29.3100 29.2860 29.2910 43.457

.000

.000 59-61 41.544 17.119

.000

INSTRUMENT CALIBRATED DATA PAGE 6(

l READING #219 AT 14:25:45 11/26/87 l

POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.461 74.564 74.944 73.990 6-18 71.886 72.367 73.100 74.185 80.423 11-15 81.128 80.146 82.618 77.301 76.043 16-28 77.578 78.013 73.102 76.845 7*.069 21-25 72.934 63.188 70.864 70.101 71.'886 26-38 73.077 75.376 70.614 71.113 71.300 31-35 70.625 71.064 70.563 70.722 70.446 36-44 71.200 71.023 16.617 17.350 15.679 41-45 17.746 15.162 16.604 15.054 16.763 46-58 15.460 16.855 14.406 14.244 14.446 51-52 14.963 14.826 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3100 29.2840 29.2890 43.524

.000

.000 59-61 41.509 17,137

.000 READING #228 AT 14 3.N5:47 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.709 74.507 74.611 74.990 73.990 6-18 71.C86 72.414 73.100 74.185 60.423 11-15 80.895 80.194 82.711 77.301 76.043 16-29 77.532 78.013 73.102 76.891 74.069 21-25 72.980 63.234 70.911 70.147 71.833 26-38 73.124 75.423 70.661 71.159 71.493 31-35 70.672 71.110 70.517 70.722 70.446 36-48 71.246 71.023 16.585 17.277 15.698 41-45 17.672 15.200 16.572 15.118 17.123 46-58 15.478 16.777 14.470 14.349 14.505 51-52 15.073 14.890 PRESSURE (PSIA)

DEW POINT TEPPERATURE 53-55,56-58 29.3120 29.2870 29.2900 43.376

.000

.000 59-61 41.499 17.276

.000 READING #221 AT 14:45:48 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.756 74.461 74.518 74.897 73.990 6-18 71.932 72.414 73.100 74.139 80.377 11-15 81.081 80.009 82.665 77.254 75.997 l

16-28 77.532 77.920 73.102 76.938 74.022 21-25 72.934 63.234 70.864 70.101 71.839 26-38 73.124 75.237 70.661 71.113 71.447 31-35 70.672 71.110 70.517 70.768 70.446 36-48 71.153 71.023 16.549 16.873 15.661 41-45 17.544 15.163 16.581 15.082 17.224 f

46-54 15.442 16.878 14.433 14.358 14.515 51-52 14.990 14.899 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3100 29.2840 29,2890 43.353

.000

.000 59-61 41.477 17.119

.000 1

JNGTRUMENT CAL I BRATED DATA PAGE G3 READING #222 AT 14:55:49 11/26/67

\\

POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.663 74.46; 74.564 74.944 73.990 6-18 71.886 72.414 73.054 74.139 80.516 11-15 81.174 80.148 82.525 77.Q01 76.043 16-28 77.532 78.059 73.146 76.891 74.022 21-25 72.980 63.234 70.864 70.101 71.686 26-34 73.124 75.284 70.614 71.020 l

71.632, 31-35 70.625 71.064 70.517 70.768 70.400 36-48 71.153 70.977 16.760 17.222 15.775 (

41-45 17.617 15.191 16.884 15.063 17.205 l

46-58 15.469 16.951 14.461 14.340 14.49G 51-52 14.972 14.88; PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-54 29.3110 29.2540 29.2890 43.403

.000

.000 59-61 41.459 17.267

.000 READING #223 AT 15: 5:49 11/26/87 POINTS:

TEMPERATURE (FAHREhHEIT) 1-5 69.709 74.507 74.611 74.990 73.990 6-19 71.8G6 72.414 73.100 74.185 80.423 11-15 81.221 80.148 82.943 77.301 75.997 16-29 77.578 78.059 73.194 76.938 74.069 21-23 72.980 63.234 70.864 70.147 71.932 26-39 73.124 75.330 70.614 71.113 71.310 31-35 70.625 71.110 70.563 70.815 79.492 36-48 71.200 71.023 16.861 17.782 15.973 41-45 18.085 15.246 17.031 15.164 17.490 46-54 15.524 17.026 14.470 14.441

'.643 51-52 15.073 14.981 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3090 29.2840 29.2880 43.300

.000

.000 59-61 41.428 17.105

.000 READING #224 AT 15:15:58 11/26/87 POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.663 74.507 74.516 74.944 73.990 6-19 71.886 72.414 73.054 74.139 80.377 11-15 81.174 80.148 82.71; 77.208 75.997 16-29 77.532 78.059 73.148 76.645 74.022 21-25 72.980 63.280 70.864 70.054 71.886 26-30 73.077 75.237 70.614 71.113 71.540 31-35 70.532 71.064 70.470 70.722 70.400 36-48 71.153 70.977 16.576 17.635 15.959 41-45 18.209 15.237 17.022 15.109 17.573 46-54 15.469 16.905 14.461 14.340 14.542 51-52 15.018 14.926 PRESSURE (PSIA)

DEW POINT TEMPERATURE I

53-55,56-54 29.3100 29.2830 29.2870 43.268

.000

.000 59-61 41.373 17.317

.000

I I N EliB T R L.AM E N T C A L_ I Eib R A T E D DATA _

PAGE diir READING #225 AT 15:25:51 11/26/87

' POINTS:

TEMPERATURE (FAHRENHEIT) 1-5 69.663 74.554 74.564 74.944 72.990 6-18 71.932 72.414 73.100 74.139 80.423 11-15 81.128 80.148 82.850 77.301 76.243 16-28 77.532 78.059 73.148 76.938 74.0G9 21-25 73.027 63.234 70.864 70.101 71.666 S&-38 73.124 75.330 70.568 71.159 71.647 31-35 70.G25 71.064 70.470 70.722 70.400 36-49 71.200 70.977 16.797 17.534 15.85a 41-45 18.612 15.226 16.691 15.146 17.472 46-54 15.460 17.080 14.498 14.331 14.533 53-52 15.054 14.963 PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29,3090 29.263C 29.28A0 43.313

.000

.000 59-61

/

41,347 17.231

.000 READING #22& AT 15:35:52 11/26/87 POINT:h TEMPERATURE (FAHRENHEIT) 1-5 69.663 74.461 74.564 74.990 73.943 6-18 71.686 72.367 73.100 74.139 BO.470 11-15 80.635 80.102 82.525 77.254 75.997 16-29 77.578 77.920 73.148 76.691 74.069 22-25 72.930 63.280 70.864 70.10; 7;.88G 26-38 73.124 75.423 70.614 71.020 71.544 31-3M 70.625 71.110 70.470 70.768 70.400 36-42 71.200 70.977 16.714 17.222 25.826 41-45 17.984 15.237 16.567 15.155 17.205 46-58 15.515 17.273 14.461 14.386 14.542 51-52 15.018 14.972-PRESSURE (PSIA)

DEW POINT TEMPERATURE 53-55,56-58 29.3070 29.2800 29.2830 43.268

.000

.000 59-61 41.337 17.145

.002 I

)

i

y -

C At_ I B R A T I O N,_,.Q A T A BY P C2_I N T PAGE 1

LOWER CONTAINMENT 24 SENSOR PGINTS 27-1% M.DG VOi dM E f

POINT VOLUME A

B(X)

C(X**2) 1 45280

.409058D+03

.4223'1D+01

.190389D-02 2

.05300

.408314D+03 421350D+01

.192493D-02 3

.05300

.407040D+03 419003D+01

.204037D-02 4

.05300

.407558D+03

.419942D+01

.200248D-02 5

.05300

.409019D+03

.4224270+al

.190305D-02 6

.03270

.408579D+03 421667D+01

.193426D-02 7

.03270

.408879Dd03

.422239D+01

.190070D-02 8

.03270

.408807D+03

.422093D+01-

.190730D-02 9

.03270

.409379D+03

.422903D+01

.184368D-02 10

.05300

.408908D+03

.422043D+01

.188918D-02 11

.05300

.409;570+03

.422704D+01

.188427D-02 12

.05300

.409461D+03

.423195D+0F

.186090D-02 13

.05300

.40639ED+03

.41768?D+01

.209818D-02 14

.05300

.?O8613D+03 421689D+01

.190795D-02 15

.05300

.407859D+03

.420363D+01

.198799D-02 16

.05300

.40?112D+03

.4225E4D+01

.188415D-02 17 05300

.408256D+03

.420751Tc+01

.194883D-02 18

.01200

.408878D+03

. 42130F,D+01

.190069D-02 19

.01010

.409141D-03

. 4 2 2 5 L ?,D + 0 1

.189583D-02 20

.J1160

.409729D+03

.423259D+01

.187360D-02 21

.01160

.405614D+03

.415846D+01

.214685D-02 25

.05.730

.409847D+03

.421908D+01

.190947D-02 26

.04.90

.408690D+03

.42164SO+01

.192061D-02 27

.03390

.408915D+03

.422301D+01

.188212D-02 PRESSURE POIN1S 53 1.00000

.000000D+00

.100000D+02

.000000D+00 DEW POINT SENSORS 56 1.00000

.850000D+02

.450000D+00

.000000D+00 57

.00000

.000000D+00

.000000D+00

.000000D+00 l

C A L_ I B R A T I O N DATA BY POINT PAGE 3E2 LPPER CONTAINMENT 13 SENSOR POINTS 59.5% BLDG VOLUME POINT VOLUME A

B(X)

C(X**2) l 22

.02000

.408890D+03

.422246D+01

.189205D-02 23

.05900

.405264D+03

.415928D+01

.218137D-02 24

.04500

.409437D+03

.422861D+01

.389526D-02 l

28

.05900

.408885D+03

.422224D+01

.190330D-02 29

.05900

.407755D+03

.420011D+01

.199057D-02 30

.05900

.408692D+03

.421647D+01

.192812D-02 1

31

.05900

.408505D+03

.421498D+01

.194284D-02 l

32

.11500

.409125D+03

.4223370+01

.186883D-02 33

.11500

.409247D+03

.422757D+01

.186871D-02 34

.11000

.409236D+03

.422737D+01

.188705D-02 35

.11000

.406924D+03

.418468D+01

.206855D-02 36

.09500

.409008D+03

.422225D+01

.189251D-02 37

.09500

.408150D+03

.420472D+01

.196228D-02 i

PRESSURE POINTS 1

54 1.00000

.000000D+00

.100000D+02

.000000D+00 DEW POINT SENSORS 58

.00000

.000000D+00

.000000D+00

.000000D+00 59 1.00000

.850000D+02

.450000D+00

.000000D+00

C A L_ I 49 F4 AT I O N DATA BY PO_ INT PAGEE 3

ICE CONDENSER 15 SENSOR POINTS 13.4% BLDG VOLUME POINT YOLUME A

B(X)

C ( X **2 )

38

.05720

.409300D+03

.422775D+01

.188745D-02 39

.05720

.409688D+03

.423205D+01

.184061D-02 40

.05720

.409282D+03

.422706D+01

.185602D-02 41

.05720

.408837D+03

.421669D+01

.190177D-02 42

.05720

.408964D+03

.422231D+01

.189151D-02 43

.05720

.409598D+03

.423226D+01

.186644D-02 44

.05720

.407600D+03

.419505D+01

.199406D-02 45

.05720

.408984D+03

.422114D+01

.191567D-02 46

.05720

.408625D+03

.421489D+01

.191266D-02 47

.05720

.408679D+03

.421767D+01

.193595D-02 48

.08560

.408762D+03

.421613D+01

.192452D-02 49

.08560

.409023D+03

.422414D+01

.188607D-02 50

.08560

.408828D+03

.421957D+01

.190956D-02 51

.08560

.408611D+03

.421473D+01

.191359D-02 52

.08560

.408613D+03

.421630D+01

.191723D-02 PRESSURE POINTS 55 1.00000

.000000D+00

.100000D+02

.000000D+00 DEW POINT SENSORS 60 1.00000

.850000D+02

.450000D+00

.000000D+00 61

.00000

.000000D+00

.000000D+00

.000000D+00 l

_ - _ _ _ _ _ - -