Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20214U627 + (ML20214U627)
- ML20214U630 + (ML20214U630)
- ML20214U633 + (ML20214U633)
- ML20214U639 + (ML20214U639)
- ML20214U644 + (ML20214U644)
- ML20214U646 + (ML20214U646)
- ML20214U651 + (ML20214U651)
- ML20214U652 + (ML20214U652)
- BECO-87-092, Application for Amend to License DPR-35,consisting of Proposed Change 87-10,revising Operability Requirements of Control Rod Block Actuation Instrumentation to More Closely Correspond to Logic Design + (ML20214U654)
- ML20214U664 + (ML20214U664)
- ML20214U667 + (ML20214U667)
- ML20214U672 + (ML20214U672)
- ML20214U673 + (ML20214U673)
- ML20214U675 + (ML20214U675)
- IA-85-272, Forwards Util Rept Re Investigation of Allegation 4-84-A-15. No Addl Insp Effort Required + (ML20214U680)
- ML20214U680 + (ML20214U680)
- IR 05000416/1986024 + (ML20214U684)
- TXX-6480, Interim Deficiency Rept CP-86-83 Re Use of Separation Barrier Matl on Power Cables & Power Raceways.Initially Reported on 861208.Nonconformance Rept CE-87-4577 Dispositioned.Next Rept Will Be Submitted by 870828 + (ML20214U685)
- ML20214U687 + (ML20214U687)
- ML20214U689 + (ML20214U689)
- ML20214U696 + (ML20214U696)
- ML20214U697 + (ML20214U697)
- ML20214U699 + (ML20214U699)
- ML20214U704 + (ML20214U704)
- ML20214U707 + (ML20214U707)
- ML20214U708 + (ML20214U708)
- ST-HL-AE-2194, Forwards Annotated Rev to FSAR Section 7A.II.K.3.17 Re NUREG-0737 Position on Repts of Outages of Eccs.Info Re ECCS Outages Will Be Submitted in Written Rept Following 5 Yrs of Commercial Operation.Rev to Be Incorporated in Future Amen + (ML20214U710)
- ML20214U711 + (ML20214U711)
- ML20214U713 + (ML20214U713)
- ML20214U715 + (ML20214U715)
- ML20214U720 + (ML20214U720)
- IR 05000317/1986010 + (ML20214U721)
- ML20214U722 + (ML20214U722)
- ML20214U723 + (ML20214U723)
- 05000293/LER-1987-006, :on 870506,structural Analysis of 870313 Insp of Hydraulic Control Unit Frames Concluded That Design Basis Operability of Units Could Not Be Established for Loading Conditions.Cause Undetermined.Frames Restored + (ML20214U725)
- ML20214U730 + (ML20214U730)
- ML20214U731 + (ML20214U731)
- ML20214U732 + (ML20214U732)
- ML20214U734 + (ML20214U734)
- ML20214U735 + (ML20214U735)
- ML20214U736 + (ML20214U736)
- ML20214U738 + (ML20214U738)
- ML20214U741 + (ML20214U741)
- ML20214U746 + (ML20214U746)
- ML20214U747 + (ML20214U747)
- PNO-III-87-078A, on 870529,NRC Insp Determined That Shifts Supervisor Observed Dozing on 870524.Licensee Appears to Have Violated NRC Shift & Overtime Policies.Addl Senior Reactor Operators Assigned on Shift to Eliminate Overtime + (ML20214U748)
- ML20214U749 + (ML20214U749)
- ML20214U750 + (ML20214U750)
- ML20214U751 + (ML20214U751)
- ML20214U754 + (ML20214U754)
- TXX-6381, Final Deficiency Rept CP-77-D Re Operation of Safeguard Actuation Reset Circuitry.Initially Reported on 770920. Operating Procedures ICI-4013A & ICI-4014A Revised & in Review Prior to Issuance.Procedures Expected by 870930 + (ML20214U756)