- 05000267/LER-1985-031, :on 851229,as Circulator B Cleared Out for Environ Qualification Work,No Automatic Action Occurred as Result of buffer-mid-buffer Trip Logic Actuation.Caused by Water in buffer-mid-buffer Sense Lines + (ML20137N458)
- 05000255/LER-1986-001, :on 860106,investigation Initiated Re Us Ecology Hanford Reservation Receipt of Radwaste Shipment 85-054-S.Shipment Received & Buried on 851230 W/O Written Ack.Written Ack Received on 860113 + (ML20137N460)
- ML20137N463 + (ML20137N463)
- 05000309/LER-1996-043, :on 961227,GL 96-01 Identified Surveillance Issues Discovered.Evaluated All GL 96-01 Issues & Resolved &/Or Tested Prior to Plant Restart + (ML20137N464)
- ML20137N465 + (ML20137N465)
- ML20137N466 + (ML20137N466)
- BSEP-97-0124, Provides Info Re Licensed Operator Qualification Program + (ML20137N467)
- 05000352/LER-1985-100, :on 851226,hourly Fire Watch Insps for Four Reactor Encl Fire Barriers Not Performed within Required Time Frame.Caused by Negative Encl Pressure,Due to Supply Fan Trip,Preventing Opening of Airlock Doors + (ML20137N468)
- ML20137N471 + (ML20137N471)
- ML20137N473 + (ML20137N473)
- ML20137N479 + (ML20137N479)
- ML20137N481 + (ML20137N481)
- 05000331/LER-1997-004, :on 970223,three of Four MSL Low RP Isolation Instrumentation Not in Agreement W/Preferred Direction of Numerical Values in Ts.Revised Engineering Setpoint Calculation & Plant Calibr Procedures + (ML20137N482)
- ML20137N483 + (ML20137N483)
- IR 05000322/1985038 + (ML20137N486)
- ML20137N487 + (ML20137N487)
- ML20137N489 + (ML20137N489)
- ML20137N491 + (ML20137N491)
- ML20137N494 + (ML20137N494)
- ML20137N496 + (ML20137N496)
- ML20137N498 + (ML20137N498)
- ML20137N499 + (ML20137N499)
- ML20137N500 + (ML20137N500)
- ML20137N502 + (ML20137N502)
- ML20137N503 + (ML20137N503)
- ML20137N506 + (ML20137N506)
- ML20137N507 + (ML20137N507)
- ML20137N510 + (ML20137N510)
- ML20137N511 + (ML20137N511)
- ML20137N513 + (ML20137N513)
- ML20137N514 + (ML20137N514)
- ML20137N515 + (ML20137N515)
- 05000255/LER-1985-031, :on 851228,during Test of New Undervoltage Relays,Diesel Generator 1-2 Auto Started & Failed to Shed Load.Caused by Improperly Installed Relays & Dirty & Misaligned Contacts.Engineers Counseled + (ML20137N518)
- ML20137N521 + (ML20137N521)
- NPL-97-0145, Submits Supplemental Info to TS Change Request 192, Requesting to Incorporate Allowed Outage Times Similar to Those Contained in Improved Standard Tech Specs + (ML20137N523)
- ML20137N525 + (ML20137N525)
- ML20137N527 + (ML20137N527)
- ML20137N529 + (ML20137N529)
- ML20137N532 + (ML20137N532)
- ML20137N535 + (ML20137N535)
- ML20137N539 + (ML20137N539)
- ML20137N540 + (ML20137N540)
- 05000266/LER-1997-012, :on 970304,diesel-drive Fire Pump Day Tank Not Sampled IAW TSs.Non-conservative Interpretation of TS Led to Failure.Day Tank T-30 Sample Was Drawn & Analyzed W/Satisfactory Results + (ML20137N541)