ML20137N502

From kanterella
Jump to navigation Jump to search
NPDES Monthly Discharge Monitoring Rept for Feb 1997
ML20137N502
Person / Time
Site: Millstone  Dominion icon.png
Issue date: 02/28/1997
From:
NORTHEAST NUCLEAR ENERGY CO.
To:
Shared Package
ML20137N498 List:
References
NUDOCS 9704080383
Download: ML20137N502 (44)


Text

__.

i DMR Processing D10872/ Enclosure SES-97-GN-043 March 31,1997 Millstone Nuclear Power Station Northeast Nuclear Energy Company Results and Discussions NPDES Monthly Report - February 1997 l

t Introduction This repon fulfills the monitoring requirements for Millstone Nuclear Power Station, NPDES Permit No. CT0003263, renewed December 14,1992.

As requested in Form Letter, DEP to each NPDES facility, dated January 1,1988 (C01988), and

- recognizing DEP's requirement'to submit data to EPA, NNECO will make every effon possible to submit the DMRs by the 20th of the month. However, in cases where the required data are not available, the DMRs will be submitted no later than the last day of the month in which they are due.

Egsults and Discussions Results of the continuous, weekly and monthly monitoring programs are summarized on the DMR sheets attached. With the exception of hydrazine, ethanolamine and boron, all sampling and analyses were conducted in accordance with approved procedures set forth in EPA i

Publication 600/4-79-02. As the plant is unaware of an EPA approved method for analysis of hydrazine, boron, and ethanolamine, Nonheast Nuclear Energy Company submitted its own procedures (D10309) for DEP approval on October 4,1996.

The computerized data logging report of the continuous monitoring program is included as Table I for each month. This repon is included because it provides data for the daily range of pH, temperature and flow, a requirement of the NPDES permit. The DMR form does not have provisions for daily ranges. These data are computer-generated summaries of 15 minute sample averages.

General Note - DMR Forms The DMR fonns have some errors, omissions, and incorrect reponing requirements when compared to the permit requirements. They are included and defined on Table 2.

i I

9704080383 970331 PDR ADOCK 05000245 R

PDR l

4

O,

-- DMR Processing

]

D10872/ Enclosure 3

SES-97-GN-043 March 31,1997 i

' Hydrarine Removal Prior to Discharae via DSN 001C-2

~

On the dates listed below, wastewaters containing small amounts of hydrazine were detected in

'{

one of the High Level Waste Drains Tanks (HLWDT) associated with DSN 001C-2. Consistent J

with the manner in which similar wastewater has been previously handled, and as described in i

correspondence (D10682, D10715 and D10751) to the Department, the wastewaters in the j

J HLWDT were processed through the demineraltzers and filters associated with DSN 001C-2 nior to discharge from the Waste Test Tanks. These wastewaters met all limits associated with 3SN 001C-2. Further, no hydrazine above detectable limits (< 5 ppb) using spectrophotometry was found. The dates and volumes discharged are provided below. These discharges were previously reported in writing (D10873) to the Department.

Dalg Volume Discharged I

' February 1,1997*

16,590 gallons

- February 8,1997 17,010 gallons-l February 15,1997 17,010 gallons j

February 22,1997 18,900 gallons

  • Sampled January 31, 1997 but discharged February 1,1997. This discharge was previously 4

reported in the January 1997 DMR.

Hydrarine Removal Prior to Discharoino DSN 001C-3 e

Wastewaters containing small amounts of hydrazine were detected in the Low Level Waste Drains Tank (LLWDT) associated with DSN 001C-3. Consistent with the manner in which this wastewater has been previously handled, the wastewater in the LLWDT was processed through filters associated with DSN 001C-3 and recirculated within the LLWDT to remove hydrazine to below detectable limits based on spectrophotometry (<5 ppb). These wastewaters met all limits associated with DSN 001C-3. The dates and volumes discharged are provided below. These f

discharges were previously reported in writing (D10751) to the Department.

i Dals Volume Discharged February 1,1997*

3,600 gallons February 1,1997 3,200 gallons

- February 1,1997 3,600 gallons

  • Sampled January 31, 1997 but discharged February 1,1997. This discharge was previously reported in the January 1997 DMR.

I e

1 DMR Processing D10872/ Enclosure SES-97-GN-043 -

March 31,1997 j

Discharue of Unit 2 Reactor Buildine Closed Coolinu Water (RBCCW) Sumo Wastewater NNECO has previously discussed with the Department the discharge via DSN 001B-9 of certam j

wastewaters due to service water header leakage at Unit 2. Due to maintenance activities in the plant, the normal pathway (DSN 001B-5) could not be used, and these wastewaters were 1

1 directed to the RBCCW sump and discharged from DSN 001B-9. The source of the water was 1

service water. This wastewater was discharged on the following dates through DSN 001B-9 and has been reponed previously in writing to the Department (D10837). At the time of each discharge, hydrazine was not detected (<350 ppb) usmg the titration method I

Dgg Volume Discharned February 18,1997 8,000 gallons February 19,1997 7,952 gallons l

February 20,1997 10,256 gallons February 21,1997 4,452 gallons 4

February 22,1997 2,324 gallons February 24,1997 644 gallons 3

j With respect to the wastewater discharged on February 18, 1997, this discharge was verbally reported to the department on February 19,1997 and in writing on February 24,1997 (D10837).

This discharge occurred with only one service water pump in operation. Pursuant to Millstone Station's NPDES Permit, discharge permit requirements for DSN 001B-9 include the following:

j t

"A minimum of two condenser circulating pumps shall be in service on Unit 2 during discharge except during Unit 2 shutdowns During Unit 2 shutdowns, the maximum discharge flow shall l

be 8.5 gallons per minute and a minimum flow equivalent to two service water pumps shall be in service on Unit 2 during discharge." With the concurrence of the Department, this provision refers to the specific situation where a shutdown Unit 2 includes the shutdown of the circulating pumps. Accordingly, the limitation on discharge flow does not apply when at least two

)

condenser circulating pumps are in operation. In this instance, the maintenance activity was terminated after 8,000 gallons were discharged when it was realized that the discharge was occurring with only one service water pump in operation.

Discharue of Unit 2 Deicine Pit On February 6,1997 approximately 1920 gallons of wastewater from the Unit 2 deicing pit were discharged. The water was analyzed and met all discharge criteria for DSN 001B-9 prior to l

discharge. Due to the similarity in source water, the results are reported in DSN 001B-9 in this report.

j l

.f DMR Processing D10872/ Enclosure SES-97-GN-043 March 31,1997 DSN016 Due to insufficient discharge flow, the monthly stormwater sample could not be taken.

f Somov Water Potentially Identified in Unit 3 Turbine Buildinn Floor Drain On February 19,1997, a worker noticed what appeared to be soapy water in a Unit 3 Turbine Building Floor Drain. The floor drain system discharges to DSN 006. DSN 006 was immediately.

sampled and evaluated for evidence of the presence of soapy water. None was found. It was therefore inconclusive how much, if any, soapy water solution was actually discharged. The cleaning staff were reminded of best management practices for these types of substances.

Unit 3 Auxiliary Boiler Discharne via DSN 001C-6(b)

Results from the analysis of this discharge are included on Table 5.

I l

l 5

i

l STATE OF CONNECTICUT " DEPARTMENT OF ENV1RONMENTAL PROTECTION Bureau of Water Managemerd - Discharge Monitoring Report (DMR)

DATE RECEIVED (STAMPED)

Permit CT000326 MAJ Dist: 12 Town:152 Loc 003 l

l Facility: MILLSTONE NUCLEAR POWER STA.

Contact:

Paul Jacobson Town: WATERFORD Phone: (860) 447-1791 Ext. 2335 Logged:

Delivered:

OK'd:

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flow 2738000000 GPD ND = none detected Discharg 0011 Mon Loc-1 COOLING WATER < 5000 Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Mnimu Freq 1

2 3

4 5

50064 121492 0/1 G

MG/L CHLORINE, FREE AVAILA ND

<0.02 01/07 <0.02 <0.02 0.02 <0.02

~

50060 121492 0/1 G

MG/L CHLORINE, TOTAL RESID ND

<0.02 01/07 <0.02 <0.02 <0.02 <0.02

~

~

50050 121492 0/1 i

MGD FLOW, IN CONDUlT OR THRU 1128.9 24/01 SEE ATTACHED TABLE 1

~

~

00400 121492 0/1 G

SU PH 7.9 8.2 24/01 SEE ATTACHED TABLE 1 00018 121492 Oli i

DEG TEMP DIFF BETWEEN SAMP 0.2 1.7 3.2 02/14 SEE ATTACHED TABLE 1 00011 121492 Oli i

DEG TEMP. DEG FAHRENHEIT 37.8 39.2 41.0 24/01 SEE ATTACHED TABLE 1 l

00015 121492 0/1 CA BTU / THERMAL DISCHARGE MILLION 113.8 575.2 01/01 SEE ATTACHED TABLE 1 KEY: CT0003263 issue: 173492 Expire: 12/14/97 Sample Month February 1997 Average Flow-2738000000 GPD ND = none detected Discharg 0011 Mon Loc-7 COOLING WATER < 5000 Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

[

5 00011 121492 0/1 1

DEG TEMPERATURE DEG FAHR 40.4 24/01 SEE ATTACHED TABLE 1 COMMENTS:

Page 1

STATE OF CONNECTICUT " DEPARTWENT OF ENVIRONMENTAL PROTECTION Bureau of Water "?- g=,ea - Dacharge Monitonng Report (DMR)

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month Fetruant 1997 Average Flow-604000000 GPD ND = none deteded i

D6sduwg 001 A Mon Loc-1 COOLING WATER < 5000 Sample Weeks:

Code Start s/m Typ Unit Parameter Mwwmu AveraDe Mammu Freq 1

2 3

4 5

j i

50064 120192 Oli G

KG/D CHLORINE, FREE AVAILABLE 142 01/07 L

50064 120192 0/1 G

MG/L CHLORINE, FREE AVAILA ND 0.13 01/07 <0.02 <0.02 <0.02 0.13 Unit shutdown, upstream flows only.

01042 091986 0/0 CP UG/L COPPER, TOTAL (AS CU) 01/90 No discharge 50050 091986 0/0 1

MGD FLOW, IN CONDUIT OR THRU 29 24/01 SEE ATTACHED TABLE 1 Upstream flows only. No circ water flow.

.01051 091986 0/0 CP UG/L LEAD, TOTAL (AS PB) 01/90 No G.G v.

01067 091986 0/0 CP UG/L NICKEL, TOTAL (AS NI) 01/90 No discharge 00610 091986 0/0 CP UG/L NITROGEN, AMMONIATOTAL 01/90 No discharge I

00556 091986 0/0 CP UG/L OIL & GREASE FREON EXTR 01/90 No discharge j

00400 091986 0/0 l

SU PH 7.7 6.0 24/01 SEE ATTACHED TABLE 1 Unit shutdown, upstream flows only.

00530 091986 0/0 CP UG/L SOLIDS,TOTALSUSPENDED 01/90 No decharge 36260 091986 0/0 CP UG/L SURFACTANTS(MBAS) 01/90 No discharge l

I 00016 091986 0/0 1

DEG TEMP DIFF BETWE"cN SAMPLE 2.0 3.0 4.4 01/01 SEE ATTACHED TABLE 1 Unit shutdown, upstream flows only.

i i

00011 091986 0/0 1

DEG TEMPERATURE DEG FAHR 39.0 40.4 42.3 24/01 SEE ATTACHED TABLE 1 Unit shutdown, upstream flows only.

00015 091986 0/0 CA BTU / THERMAL DISCHARGE MILLION 17.6 31.3 01/01 SEE ATTACHED TABLE 1 i

Unit shutdown, upstream flows only.

l 01092 091986 0/0 CP UG/L ZINC, TOTAL (AS ZN) 01/90 No discharge j

COMMENTS:

i Page 2 I

d

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION

~

Bureau of Water Management - DisG.eryi Monitoring Report (DMR)

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flow-604800000 GPD ND = none detected Discharg 001 A Mon Loc-G COOLING WATER < 5000 Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

01042 091986 0/0 CP UG/L COPPER, TOTAL (AS CU) 01/90 No discharge 01051 091986 0/0 CP UG/L LEAD. TOTAL (AS PB) 01/90 No discharge 01067 091966 0/0 CP UG/L NICKEL, TOTAL (AG NI) 01/90 No discharge 01/90 No discharge 00610 091986 0/0 CP UG/L NITROGEN, AMMONIA TOTAL 01/90 No discharge 00556 091986 0/0 CP UG/L OIL & GREASE FREON EXTR.

00530 091986 0/0 CP UG/L SOLIDS, TOTAL SUSPENDED 01/90 No discharge 38260 091986 0/0 CP UG/L SURFACTANTS (MBAS) 01/90 No discharge 01092 091986 0/0 CP UG/L ZINC, TOTAL (AS ZN) 01/90 No discharge COMMENTS:

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flovr. 604800000 GPD ND = none detected Discharg 001 A Mon Loc-T COOLING WATER < 5000 Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

02/99 No discharge TGB6A 091986 0/0 CP P/F P/F STAT ACU CYPRINODON TGA3E 091986 0/0 CP P/F P/F STAT ACU MYSIDOPSIS 02/99 No discharge L

02/99 No discharge TGC6A 091986 0/0 CP P/F P/F CHR CYPRINODON 02/99 No discharge TGC3E 091986 0/0 CP P/F P/F CHR MYSIDOPSIS Page 3

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION

~

Bureau of Water Management - Discharge Monitoring Report (DMR)

^

KEY: CT0003263

'., sue: 121492 Expre: 12/14/97 Sample Month February 1997 Average Flovr. 820000000 GPD ND = none detected Descharg 001 B Mon Loc-1 NON-CONTACT COOLING WATER Sample Weeks, Code Start s/m Typ Unit Parameter Minimu Avera0e Maximu Freq 1

2 3

4 5

50064 121492 0/1 G

KG/D CHLORINE, FREE AVAILABLE 125 01/07 50064 121492 0/1 G

MG/L CHLORINE, FREE AVAILABLE 0.08 01/07 0.05 0.05 0.04 0.08

~

01042 091986 0/0 CP UG/L COPPER, TOTAL (AS CU) 01/90 Last sampled 1-97

~

~

50050 121492 0/1 1

MGD FLOW,IN CONDUIT OR THRU 412 24/01 SEE ATTACHED TABLE 1

~

~

01051 091986 0/0 CP UG/L LEAD TOTAL (AS PS) 01/90 Last sampled 1-97

~

~

01067 091986 0/0 CP UG/L NICKEL, TOTAL (AS NI) 01/90 Last sampled 1-97 00610 091986 0/0 CP UG/L NITROGEN, AMMONIA TOTAL 01/90 Last sampled 1-97 00556 091986 0/0 CP UG/L OIL & GREASE FREON EXTR

~

~

01/90 Last sampled 1-97 00400 091986 0/0 1

SU PH 7.8 8.2 24/01 SEE ATTACHED TABLE 1 00530 091986 0/0 CP UG/L SOLIDS, TOTAL SUSPENDED 01/90 Last sampled 1-97 38260 091986 0/0 CP UG/L SURFACTANTS(MBAS)

~

~

01/90 Last sampled 1-97 00018 091986 0/0 I

DEG TEMP DIFF BETWEEN SAMPLE 0.0 1.0 3.8 01/01 SEE ATTACHED TABLE 1 00011 091986 0/0 l

DEG TEMPERATURE DEG FAHR 36.5 38.9 42.6 24/01 SEE ATTACHED TABLE 1 00015 091986 0/0 CA BTU / THERMAL DISCHA.tGE MILLION 9.8 64.3 01/01 SEE ATTACHED TABLE 1 r

~

01092 091986 0/0 CP UG/L ZINC, TOTAL (AS ZN) 01/90 Last sampled 1-97 COMMENTS:

Pa9e 4 i

.. ~

i GTATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION I

Bureau of Water Management - Descharge Monitoring Report (DMR)

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flovc 820000000 GPD NO = none detected Descharg 001 B Mon Loc-G NON-CONTACT COOLING WATER Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

01042 091986 0/0 CP UG/L COPPER, TOTAL (AS CU) 01/90 Last sampled 1-97 01051 091986 0/0 CP UG/L LhaD, TOTAL (AS PB)

~

01/90 Last sampled 1-97 01067 091986 0/0 CP UG/L NICKEL, TOTAL (AS NI)

~

~

01/90 Last sampled 1-97 00610 091986.

0/0 CP UG/L NITROGEN, AMMONIA TOTAL 01/90 Last sampled 1-97

~

00556 091986 0/0 CP UG/L OIL & GREASE FREON EXTR 01/90 Last sampled 1-97 00530 091986 0/0 CP UG/L SOLIDS, TOTAL SUSPENDED 01/90 Last sampled 1-97 38260 091986 0/0 CP UG/L SURFACTANTS(MBAS) 01/90 Last sampled 1-97 01092 091986 0/0 CP UG/L ZINC, TOTAL (AS ZN) 01/90 Last sampled 1-97 COMMENTS:

KEY: CT0003263 Issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flowc 820000000 GPD ND = none detected Discharg 001 B Mon Loc T NON-CONTACT COOLING WATER Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu AveraSe Maximu Freq 1

2 3

4 5

TGB6A 091986 0/0 CP P/F P/F STAT ACU CYPRINODON 02/99 Last sampled 1-97 TGA3E 091986 0/0 CP P/F P/F STAT ACU MYSIDOPSIS 02/99 Last sampled 1-97 TGC6A 091986 0/0 CP P/F P/F CHR CYPRINODON 02/99 Last sampled 1-97 TGC3E 091988 0/0 CP P/F P/F CHR MYSIDOPSIS 02/99-Last sampled 1-97 Page5

---.a

-w r

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bweeu of Weser Management - Dischmge Monitonne Report (DMR) 4-KEY: CT0003263 issue: 121492 Expwe: 12/14/97 Sample Month Fetruary 1997 Avera9e Flow 1313200000 GPD ND = none detected Discharg 001 C Mon Loc: 1 NOPKONTACT COOLING WATER Sample Weeks:

Code Start s/m Typ Unit Parameter Mwwmu Average Maximu Freq 1

2 3

4 5

50064 121492 0/1 G

KG/D CHLORINE, FREE AVAILABLE 418 01/07

~

~

50064 121492 0/1 G

MG/L CHLORINE, FREE AVAILABLE 0.12 01/07 0.07 0.10 0.11 0.12

~

~

I 01/90 Last sampled 1-97 01042 091986 0/0 CP UG/L COPPER, TOTAL (AS CU)

~

~

50050 121492 0/1 1

MGD FLOW, IN CONDUIT OR THRU 918.7 24/01 SEE ATTACHED TABLE 1

~

~

01/90 Last sampled 1-97 01051 091986 Ol0 CP UG/L LEAD, TOTAL (AS PB) i 01067 091906 Oto CP UG/L NICKEL, TOTAL (AS NI) 01/90 Last sampled 1-97 01/90 Last sampled 1-97 00610 091986 0/0 CP UG/L NITROGEN AMMONIATOTAL

~

01/90 Last sampled 1-97 00556 091986 Ol0 CP UG/L OIL & GREASE FREON EXTR 00400 091986 OIO I

SU PH 7.6

' 8.20 24/01 SEE ATTACHED TABLE 6 01/90 Last sampled 1-97 00530 091986 Ol0 CP UG/L SOLIDS, TOTAL SUSPENDED 01/90 Last sampled 1-97 i

38260 091906 0/0 CP UG/L SURFACTANTS (MBAS) 00018 091986-0/0 I

DEG TEMP DfFF BETWEEN SAMPLE 0.0 1.8 5.0 01/01 SEE ATTACHED TABLE 1 00011 091986 0/0 l

DEG TEMPERATURE DEG FAHR 38.0 39.8 43.0 24/01 SEE ATTACHED TABLE 1 00015 091986 Of0 CA BTUI THERMAL DISCHARGE MILLION 33.0 555.1 01/01 SEE ATTACHED TABLE 1 I

01/90 Last sampled 1-97 01092 091986 OIO CP UG/L ZINC TOTAL (AS ZN)

COMMENTS:

)

I i

Page 6

)

J

CTATE OF CONNECTICUT ** DEPARTMENT OF ENVIRONMENTAL PROTEC110N

~

Bureau of Water Management - Discharge Monitoring Report (DMR)

KEY: CT0003263 Issue: 121492 Expire: 12/14/97 Sample Month Fetxuary 1997 Average Flovr.1313200000 GPD ND = none detected Discharg 001 C Mon Loc-G NON-CONTACT COOLING WATER Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

01042 091986 0/0 CP UG/L COPPER, TOTAL (AS CU) 01/90 Last sampled 1-97 L

01051 091986 0/0 CP UG/L LEAD, TOTAL (AS PB) 01/90 Last sampled 1-97 01067 091986 0/0 CP UG/L NICKEL, TOTAL (AS NI) 01/90 Last sampled 1-97 00610 091986 0/0 CP UG/L NITROGEN, AMMONIA TOTAL 01/90 Last sampled 1-97 00556 091986 0/0 CP UG/L OlL & GREASE FREON EXTR 01/90 Last sampled 1-97 00530 091986 0/0 CP UG/L SOLIDS, TOTAL SUSPENDED 01/90 Last sampled 1-97 38260 091986 0/0 CP UG/L SURFACTANTS(MBAS) 01/90 Last sampled 1-97 01092 091986 O/0 CP UG/L ZINC, TOTAL (AS ZN) 01/90 Last sampled 1-97 COMMENTS:

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month Fetxuary 1997 Average Flow-1313200000 GPD ND = none detected Discharg 001 C Mon Loc-T NON-CONTACT COOLING WATER Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu AveraQe Maximu Freq 1

2 3

4 5

TGB6A 091986 0/0 CP P,7 P/F STAT ACU CYPRINODON 02/99 Last sampled 1-97 TGA3E 091986 0/0 CP P/F P/F STAT ACU MYS:DOPSIS 02/99 Last sampled 1-97 TGC6A 091986 0/0 CP P/F P/F CHR CYPRINODON 02/99 Last sampled 1-97 TGC3E 091986 0/0 CP P/F P/F CHR MYSIDOPSIS 02/99 Last sampled 1-97 Page 7 i

CTATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Discharge Monitoring Report (DMR)

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flow-INTERMITT GPD ND = none detected Discharg 005 Mon Loc 1 STORMWATER Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

00056 120192 Ol1 I

GPD FLOW RATE, AVERAGE DAILY 21600 02/99 21.6K

~

00556 120192 0/1 G

MG/L OlL & GREASE FREON EX ND

<0.5 02/99

<0.5

~

~

00530 120192 0/1 G

MG/L SOLIDS TOTAL SUSPENDED 7.2 02/99 7.2

~

~

COMMENTS:

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flow: 432000 GPD ND = none detected Discharg 006 Mon Loc 1 STEAM ELECTRIC POWER PLNT Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

00698 120192 0/1 CP KG/D BORIC ACID Code 9 01/07 00698 120192 0/1 CP MG/L BORIC ACID Code 9 01/07

~

50060 120192 0/1 G

MG/L CHLORINE TOTAL RESID ND 0.02 0.12 01/07 0.02 0.12 0.07 0.03 Weekly high values. See Table 3.

01042 120192 0/1 CP KG/D COPPER, TOTAL (AS CU) 0.0039 01/07.0015.0018.0039.0030 01042 120192 0/1 CP MG/L COPPER, TOTAL (AS CU)

ND

<0.02 01/07 <0.02 <0.02 <0.02 <0.02 00056 120192 Ol1 I

GPD FLOW RATE AVERAGE DAILY 104800 02/99 40K 49K 105K 80K

~

~

01051 120192 0/1 CP KG/D LEAD, TOTAL (AS PB) 0.0198 01/07.0075.0092.0198.0152 01051 120192 0/1 CP MG/L LEAD. TOTAL (AS PB)

ND

<0.10 01/07 <0.10 <0.10 <0.10 <0.10 01067 120192 0/1 CP KG/D NICKEL, TOTAL (AS NI) 0.0099 01/07.0037.0046.0099.0076 Comment:

Page 8 l

l STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION j

Bureau of Water FAanagemerd - Descharge Monitoring Report (DMR) 1 l

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month Fetxuary 1997 Average Flevr. 432000 GPD ND = none detected Deschstg 006 Mon Loc-1 STEAM ELECTRIC POWER PLNT l

Sample Weeks:

l Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

1 01067 120192 0/1 CP MG/L NICKEL. TOTAL (AS NI)

ND

<0.05 Of/07 <0.05 <0.05 <0.05 <0.05 00556 120192 Oli G

MG/L OIL & GREASE FREON EX ND

<0.5 0.06 01/30

<0.5

<0.5 0.5

<0.5

<0.5 0.06 00400 120192 0/1 G

SU PH 6.09 7.71 01/07 7.57 6.09 7.40 7.70 7.71 7.16 7.59 7.61 00530 120192 0/1 CP MG/L SOLIDS, TOTAL SUSPENDED 3.1 4.1 01/07 3.7 1.7 2.8 4.1 01092 120192 0/1 CP KG/D ZlNC, TOTAL (AS ZN) 0.1247 01/07.0242.0755.1032.1247

~

01092 120192 0/1 CP MG/L ZINC, TOTAL (AS ZN) 0.41 01/07 0.16 0.41 0.26 0.41 COMMENTS:

KEY: CT0003263 issue: 121492 Exp;re: 12/14/97 Sainple Month February 1997 Average Flow-432000 GPD ND = none detected Descharg 006 Mon Loc-T STEAM ELECTRIC POWER PLNT Sample Weeks:

_ Code Start s/m Typ Unit Parameter Minimu Average Freq 1

2 3

4 5

TGA3E 120192 0/0 CP P/F P/F STAT ACU MYSIDOPSIS 02/99 Last sampled 1-97 TGC3E 120192 0/0 CP P/F P/F STAT CHR MYSIDOPSIS 02/99 Last sampled 1-97 COMMENTS:

Page 9

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water".":.+;-, ra-Dacharge Monitoring Report (DMR)

~

MEY: CT0003283 issue: 121492 Expwe: 12/14/97 Sample Month Fetruent 1997 Average Flovc INTERMITT GPD ND = none detected Dacharg 006 Mon Loc-1 STORMWATER i

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

00056 120192 0/1 1

GPD FLOW RATE, AVERAGE DAILY

<1440 02/99

<1440 i

00556 120192 0/1 G

MG/L OIL & GREASE FREON EX ND

<0.5 02/99

<0.5 00530 120192 0/1 G

MG/L SOUDS, TOTAL SUSPENDED 14.2 02/99 14.2

~

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flovc INTERMITT GPD ND = none detected Discharg 009 Mon Loc 1 STORMWATER Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

00056 120192 0/1 1

GPD FLOW RATE, AVERAGE DAILY 4320 02/99 4320

~

00556 120192 0/1 G

MG/L OIL & GREASE FREON EX ND

<0.5 02/99

<0.5 00530 120192 0/1 G

MG/L SOLIDS TOTAL SUSPENDED 5.9 02/99 5.9 KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flovc INTERMITT GPD ND = none deteded Discharg 016 Mon Loc-1 STORMWATER Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

00056 120192 0/1 i

GPD FLOW RATE, AVERAGE DAILY 02/99 No Sample 00556 120192 0/1 G

MG/L Olt & GREASE FREON EXTR

~

~

02/99 No Sample 00530 120192 0/1 G

MG/L SOLIDS, TOTAL SUSPENDED 02/99 No Sample -

Page 10

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Discharge Monitoring Report (DMR)

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flow 604800000 GPD ND = none detected Discharg 01A 1 Mon Loc-1 COOLING WATER < 5000 Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu AveraDe Maximu Freq 1

2 3

4 5

00164 120192 0/1 T

GPS FLOW, GALLONS / BATCH NF 02/99 No Di"cnarge.

00400 091686 0/0 G

SU PH NF 01/07 No Discharge

~

~

00095 091686 0/0 G

HM/C SPECIFIC CONDUCTANCE NF 01/07 No Discharge

~

~

Comments:

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flow-14000 GPD ND = none detected Discharg 01 A2 Mon Loc 1 BUILDING FLOOR DRAIN Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

00164 120192 0/1 T

GPB FLOW, GALLONS / BATCH 11050 01/01 9000 9600 7050 10500 11050

~

7900 00400 091986 0/0 G

SU PH 9.03 01/07 6.90 7.82 9.03 8.88 8.57 9.01 00530 120192 0/1 G

KG/D SOLIDS TOTAL SUSPENDED 0.0109 01/07.0034.0109.0026.0079.0083

.0001 00530 120192 0!1 G

MG/L SOLIDS, TOTAL SUSPEND ND 0.3 01/07 0.1 0.3 0.1 0.2 0.2

<0.1 l

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flow: 3500 GPD ND = none detected Discharg 01 A 4 Mon Loc 1 WATER PRODUCTION WASTEWTR Sample Weeks:

Code Start s/m Typ Unit Parameter Minimo AveraQe Maximu Freq 1

2 3

4 5

00698 120192 0/1 G

KG/D BORIC ACID Code 9 H/DS 00698 120192 0/1 G

MG/L BORIC ACID Code 9 H/DS

~

~

00164 120192 0/1 T

GPB FLOW, GALLONS / BATCH 2784 01/BA NF NF NF NF 2784 Page 11 t

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Discharge Monitoring Repost (DMR)

KEY: CT0003263 issue: 121492 Expre: 12/14/97 Sample Month February 1997 Average Flow: 43200000 GPD ND = none detected Discharg 01 A 5 Mon Loc-1 NON-CONTACT COOLING WATER Sample Weeks.

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

50064 120192 0/1 G

MG/L CHLORINE, FREE AVAILA ND 0.10 01/07 <0.02 <0.02 0.10 0.06 50050 091986 0/0 I

MGD FLOW, IN CONDUlT OR THRU 14.4 01/07 14.4 14.4 14.4 14.4

~

~

00011 091966 0/0 G DEG TEMPERATURE DEG FAHR 54 01/07 41 41 54 41 COMMENTS:

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month Fetwwary 1997 Average Flow: 1,440,000 GPD ND = none detected Discharg 0181 Mon Loc: 1 BLOWDOWN FR HEAT & COOL Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

00696 091986 0/0 G

KG/D BORIC ACID Code 9 02/99 During treatment only

~

~

50050 091986 0/0 T

MGD FLOW, IN CONDUIT OR THRU 01/07 NO DISCHARGE

~

~

00530 121492 0/1 G

KG/D SOLIDS, TOTAL SUSPENDED 01/07 NO DISCHARGE i

00530 121492 0/1 G

MG/L SOLIDS TOTAL SUSPENDED

~

~

01/07 NO DISCHARGE 00011 091986 0/0 l

DEG TEMPERATURE DEG FAHR 01/07 NO DISCHARGE COMMENTS:

(

i l

Page 12

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water ??- ;-.a.;- Descharge Monitoring Report (DMR)

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month Fetnary 1997 Average Flow-5000 GPD ND = none detected Descharg 01B 2 Mon Loc-1 BLOWDOWN FR HEAT & COOL Sample Weeks Code Start s/m Typ Unit Parameter Minemu Average Maximu Freq 1

2 3

4 5

00698 120192 0/1 BC KG/D BORIC ACID 82.1 01/07 20.0 13.3 82.1 NF-NF 00164. 120192 0/1 T

GPB FLOW, GALLONS / BATCH 3056 01/07 3004 2964 3056 NF NF I

00400 091986 0/0 G

SU PH 6.91 01/07 6.91 6.60 6.75 NF NF

~

~

00530 091986 0/0 G

MG/L SOLIDS. TOTAL SUSPENDED 5.6 14.4 01/07 1.6 0.9 14.4-NF NF KEY: CT0003263 issue:121492 Expire: 12/14/97 Sample Month Fetnary 1997 Average Flow-30000 GPD ND = none detected Decharg 01B 3 Mon Loc-1 BLOWDOWN FR HEAT & COOL Sample Weeks-Code Start s/m Typ UnN Parameter Minimu Average Maximu Freq 1

2 3

4 5

00696 091986 0/0 BC KG/D BORIC ACID 410.1 01/07 NF 410.1 NF NF NF 00164 091986 0/0 T

GPB FLOW GALLONS / BATCH 12956 01/07 NF 12956 NF NF NF

^

00530 091986 0/0 G

MG/L SOLIDS, TOTAL SUSPENDED 1.8 1.8 01/07 NF 1.8 NF NF NF KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 i

Average Flow-28800000 GPD ND = none deteded Descharg 01B 5 Mon Loc-1 NON-CONTACT COOLING WATER Sample Weeks:

Code Start s/m Typ Unit Parameter Menemu Average Maximu Freq 1

2 3

4 5

f 50064 120192 0/1 G

MG/L CHLORINE, FREE AVAILA NO 0.08 01/07 <0.02 0.04 0.08 0.06 50050 120132 0/1 T

MGD FLOW, IN CONDUIT OR THRU 17.5 01/07 17.5 16.8 9.2 9.7 00011 120192 0/1 l

DEG TEMPERATURE DEG FAHR 62 01/07 62 52 51 50 Page 13

STATE OF CONNECTICUT ** DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Discharge Monitoring Report (DMR)

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month Febmary 1997 Average Flow: 25000 GPD ND = none deteded Discharg 01B 6 Mon Loc-1 WATER PRODUCTION WASTEWTR Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

00698 091986 0/0 BC KG/D BORIC ACID Code 9 02/99 l

00164 120192 0/1 T

GPS FLOW, GALLONS / BATCH 20000 01/07 NF 19700 20000 NF NF 15800 00556 120192 0/1 G

MG/L OIL & GREASE FREON EX ND 1.4 01/30 NF 1.4

<0.5 NF NF 00400 091986 0/0 G

SU PH 8.5 01/07 NF 7.0 8.5 NF NF 7.14 00530 120192 0/1 G

MG/L SOLIDS, TOTAL SUSPENDED 4.6 01/07 NF 1.3 4.6 Nt:

NF

2.9 COMMENTS

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month Fetruary 1997 Average Flow-5760000 GPD ND = none detected Discharg 01B 7 Mon Loc 1 NON-CONTACT COOLING WATER Sample Weeks:

1 Code Start s/m Typ Unit Parameter Minimu AveraDe Maximu Freq 1

2 3

4 5

50064 091986 0/0 G

KG/D CHLORINE, FREE AVAILABLE 01/07 NO DISCHARGE 50064 091986 0/0 G

MG/L CHLORINE, FREE AVAILABLE 01/07 NO DISCHARGE 50050 120192 0/1 T

MGD FLOW, IN CONDUlT OR THRU 02/99 NO DISCHARGE 00011 120192 0/1 i

DEG TEMPERATURE DEG FAHR 01/07 NO DISCHARGE COMMENTS:

Page 14

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Managemerd - Descharge Monitoring Report (DMR)

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flow 100000 GPD ND = none detected Discharg 01B 8 Mon Loc 1 BLOWDOWN FR HEAT & COOL Sample Weeks.

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

0016d 120192 0/1 T

GPB FLOW, GALLONS / BATCH

~

~

01/DD NF NF NF NF NF 81313 120192 0/1 G

MG/L HYDRAZINE 01/DD NF NF NF NF NF

~

~

01045 120192 0/1 G

MG/L IRON, TOTAL (AS FE) 01/DD NF NF NF NF NF 00400 120192 Oli l

SU PH

~

~

01/DD NF NF NF NF NF 00530 120192 0/1 G

MG/L SOLIDS, TOTAL SUSPENDED 01/DD NF NF NF NF NF

~

~

00011 120192 Ol1 G DEG TEMPERATURE DEG FAHR 01/DD NF NF NF NF NF COMMENTS:

Note 1 = Discharged through deicing pit.

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month Fetxuery 1997 l

Average Flow: 30000 GPD ND = none detected Discharg 018 9 Mon Loc 1 NON-CONTACT COOLING WATER Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

00056 120192 0/1 T

GPD FLOW RATE, AVERAGE DAILY 10256 01/DD NF 1920 10256 4452 644

~

~

Notei weeksymen Tate 4 81313 091986 0/0 G

MG/L HYDRAZINE ND

<0.350 01/DD NF

<.350 <.350 <.350 <.350

~

~

Weekly max. see Table 4 00011 120192 0/1 I

DEG TEMPERATURE DEG FAHR 69 01/DD NF 54 68 58 69 Weekly max. see Table 4 COMMENTS:

Note 1 = Discharged through deicing pit. See Results and Discussion.

Page 15

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Discharge Monitoring Report (DMR)

~

KEY: CT0003263 issue: 121492 Expre: 12/14/97 Sample Month Fetxuary 1997 Average Flow: 1400000 GPD NO = none detected Discharg 01C 1 Mon Loc-1 STEAM ELECTRIC POWER PLNT Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu AveraQe Maximu Freq 1

2 3

4 5

00698 091986 0/0 G

KG/D BORIC ACID Code 9 02/99 Conditional Monitoring 50050 120192 0/1 1

MGD FLOW, IN CONDUIT OR THRU 01/07 NO DISCHARGE 00400 091986 0/0 G

SU PH 01/07 NO DISCHARGE 00530 120192 0/1 G

MG/L SOLIDS. TOTAL SUSPENDED 01/07 NO DISCHARGE 00011 120192 0/1 G DEG TEMPERATURE DEG FAHR 01/07 NO DISCHARGE KEY: CT0003263 issue: 121492 Expre: 12/14/97 Sample Month Fetxuary 1997 Average Flow 25000 GPD ND = none detected Discharg 01C 2 Mon Loc 1 BUILDING FLOOR DRAIN Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

00698 120192 0/1 BC KG/D BORIC ACID 508.0 01/07 NF 118.5 506.0 NF NF 128.5 00164 120192 0/1 I

GPB FLOW, GALLONS / BATCH 18900 01/07 NF 17010 18900 NF NF 17010 01132 091986 0/0 G

MG/L LITHlUM, TOTAL (AS U)

ND

<0.10 01/07 NF

<0.10 <0.10 NF NF i

<0.10 j

00400 091986 0/0 G

SU PH 4.89 01/07 NF 4.89 4.44 NF NF

[

4.75 00095 091986 0/0 G

HM/C SPECIFIC CONDUCTANCE 14.9 01/07 NF 4.9 14.9 NF NF l

8.6 COMMENTS:

Page 16 i

STATE OF CONNECTICUT " DEPAPTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Descharge Monitoring Report (DMR)

KEY: CT0003263 issue: 121492 Expere: 12/14/97 Sample Month February 1997 Average Flow-5000 GPD ND = none detected Discharg 01C 3 Men Loc-1 BLOWDOWN FR HEAT & COOL Sample Weeks Code Start s/tr, Typ Unit Parameter Minimu AveraDe Maximu Freq 1

2 3

4 5

00698 120192 0/1 G

KG/D BORIC ACID 30.0 H/D 16.2 2.3 4.9 4.7 1.9 11.4 30.0 13.6 00164 120192 0/1 T

GPB FLOW, GALLONS / BATCH 3680 01/07 3200 3640 3680 3360 3200 3600 3600 3400 i

00400 091986 0/0 G

SU PH 12.15 01/07 9.10 12.15 11.60 11.74 11.65 l

8.95 8.95 9.38 00530 120192 Ol1 G

MG/L SOLIDS, TOTAL SUSPENDED 42.2 01/07 18.7 31.6 24.8 15.2 34.0 42.2 25.8 28.6 KEY: CT0003263 Issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flowc 80000 GPD ND = none detected Descharg 01C 4 Mon Loc 1 WATER PRODUCTION WASTEWTR Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

i 00164 091986 0/0 T

GPB FLOW, GALLONS / BATCH 41500 01/07 NF NF 35000 NF 48000 81313 091986 0/0 G

MG/l_ HYDRAZWE ND

<0.350 02/99 NF NF

<.350 NF

<.350 00400 091986 0/0 G

SU PH 6.70 01/07 NF NF 6.1 NF 6.7 00530 120192 0/1 G

MG/L SOLIDS. TOTAL SUSPENDED 43.5 01/07 NF NF 40.0 NF 43.5 KEY:CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flovc 43200000 GPD ND = none detected l

Discharg 01C 5 Mon Loc-1 NON-CONTACT COOLING WATER Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu AveraDe Maximu Freq 1

2 3

4 5

50064 120192 0/1 G

MG/L CHLORINE, FREE AVAILABLE 0.19 01/07 0.19 0.17 0.16 0.17 Weekly maximum. See Table 4 50050 120192 0/1 i

MGD FLOW, IN CONDUIT OR THRU 43.2 02/99 43.2 43.2 21.6 43.2 00011 120192 0/1 1

DEG TEMPERATURE DEG FAHR 47 01/07 42 40 40 47 Page 17

---e-

,s

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION

~ '

Bureau of Water Managemetd - Discharge Monitoring Report (DMR)

KEY: CT0003263 issue: 121192 Expire: 12/14/97 Sample Month February 1997 Average Flow: 25000 GPD ND = none detected Descharg 01C 6 Mon Loc 1 WATER PRODUCTION WASTEWTR Sample Weeks:

Code Start s/m Tyr Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

00164 120192 0/1 T

GPB FLOW, GALLONS / BATCH 18400 01/07 14950 18400 17250 18170 8050 11270 14950 81313 120192 Ol1 G

MG/L HYDRAZINE 4.00 02/99 0.04 0.32 0.4 0.6 0.01 4.0 0.02 00556 120192 0/1 G

KG/D OIL & GREAF" EREON EXTR 0.0339 01/30.0339

.0076 00556 120192 0/1 G

MG/L OIL & GREASE FREON EX ND 0.6 01/30 0.6

<0.5 00400 091986 0/0 G

SU PH 7.97 01/07 7.0 7.80 7.97 7.53 7.5 7.9 7.1 00530 120192 0/1 G

KG/D SOLIDS, TOTAL SUSPENDED 0.36 01/07 0.27 0.27 0.36 0.34 0.06 0.31 0.09 00530 120192 0/1 G

MG/L SOLIDS, TOTAL SUSPENDED 7.4 01/07 4.9 4.0 1.1 4.9 l

2.2 7.4 1.7 00011 120192 0/1 G DEG TEMPERATURE DEG FAHR 70 01/07 62 69 67 70 67 68 KEY: CT0003263 issue: 121492

' Expere: 12/14/97 Sample Month February 1997 Average Flovc 100000 GPD ND = none detected Discharg 01C 8 Mon Loc: 1 BLOWDOWN FR HEAT / COOL Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Maximu. Freq 1

2 3

4 5

[

t 00164 120192 0/1 BC GPB FLOW, GALLONS / BATCH 02/99 NF NF NF NF NF

[

81313 120192 0/1 G

MG/L HYDRAZINE 01/DD NF NF NF NF NF 01045 120192 Ol1 G

MG/L IRON, TOTAL (AS FE) 01/DD NF NF NF NF NF 00400 091986 0/0 G

SU PH 01/DD NF NF NF NF NF 00530 120192 0/1 G

MG/L SOLIDS, TOTAL SUSPENDED 01/DD NF NF NF NF NF 00011 120192 0/1 G DEG TEMPERATURE DEG FAHR 01/DD NF NF NF NF NF Page 18

i STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water _ _--

- Discharge Monitoring Report (DMR) l KEY: CT0003263 issue: 121492 Expwe: 12/14/97 Sample Month - February 1997 i

Average Flour. 300000 GPD ND = none detected -

Discharg 01C 9 Mon Loc 1 NON-CONTACT COOLING WATER t

i Code Start s/m Typ Unit Parameter Mmimu Average Maximu Freq 1

2 3

4 5

00056 120192 0/1 i

GPO FLOW RATE. AVERAGE DAILY 400 01/DD - 195 NF NF NF NF 400 -

t

$1313 091966 0/0 G

MG/L HYDRAZINE ND

<0.350 01/DD <.350 NF NF NF NF

< 350 00011 120192 0/1 G DEG TEMPERATURE DEG FAHR 73 01/DD S2 NF NF NF NF l

73 KEY: CT0003263 issue:121492 Expire: 12/14/97 Sample Month Fetruary 1997 Average Flour. 220 GPD NO = none detoded Discharg 1A2 A Mon Loc 1 MISC LAUNDRY & GARMENT i

Sample Weeks j

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

[

01/DD NO DISCHARGE l

00164 120192 0/1 T

GPS FLOW, GALLONS / BATCH 01/DD NO DISCHARGE 70015 091966 0/1 G

MG/L FREON, TOTAL 00556 120192 0/1 G

MGIL OIL & GREASE FREON EXTR 01/DD NO DISCHARGE

[

I KEY: CT0003263 issue: 121492 Expwe: 12/14/97 Sample Month February 1997 Average Flour. 6500 GPO ND = none detected Descharg 1 A2 B Mon Loc-1 MISC LAUNDRY & GARMENT Code Start s/m Typ Unit Parameter M6nimu Average Maxime Freq 1

2 3

4 5-00164 120192 0/1 T

GPB FLOW, GALLONS / BATCH 01/DD NO DISCHARGE 01/DD NO DISCHARGE

[

70015 091986 0/1 G

MG/L FREON, TOTAL 00556 120192 0/1 '

G MG/L OIL & GREASE FREON EXTR 01/DD NO DISCHARGE t

Page 19 i

m

. m.

m._

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Dacharge Monitoring Report (DMR)

~

MEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month Fetwuary 1997 l

Average Flow. 70000 GPD ND = none detected l

Dacharg 181 A

. Mon Loc-1 BLOWDOWN FR HEAT & COOL Sample Weeks-Code Start s/m Typ Unit Parameter Minemu Average Maximo Freq 1

2 3

4 5

l 00164 120192 0/1 G

GPS FLOW, GALLONS / BATCH 01/DD NO DISCHARGE j

)

01/DD NO DISCHARGE 81313 120192 0/1 i

KG/D HYDRAZINE 81313 120192 0/1 1

MG/L HYDRAZINE 01/DD NO DISCHARGE 01/DD NO DISCHARGE 00011 120192 0/1

~l DEG TEMPERATURE DEG FAHR KEY: CT0003263 issue: 121492 Expere: 12/14/97 Sample Month February 1997

}

Average Flow 107000 GPD ND = none detected Descharg 1B2 A.

Mon Loc 1 BLOWDOWN FR HEAT & COOL Code Start s/m Typ Unit Parameter Menemu Average Maximu Freq 1

2 3

- 4 5

i 00619 091986 0/0 CP MG/L AMMONIA, UNIONIZED 01/07 NO DISCHARGE l

i 00998 091986 Ol0 CP MG/L BERYLLIUM, TOTAL RECOVE 01/DD NO DISCHARGE 00310 091986 O/0 CP MG/L BOD 5 DAY (20 DEG C) 01/07 NO DISCHARGE 01/DD NO DISCHARGE

[

01027 091986 0/0 CP MG/L CADMlUM TOTAL (AS CD) l 00335 091986 Ol0 CP MG/L CHEMICAL OXYGEN DEMAND 01/DD NO DISCHARGE i

01/DD.

NO DISCHARGE I

01034 091986 0/0 CP MG/L CHROMlUM, TOTAL (AS CR) 01042 091986 0/0 CP MG/L COPPER, TOTAL (AS CU) 01/DD NO DISCHARGE i

01/DD NO DISCHARGE 00164 120192 0/1 G

GPB FLOW, GALLONS / BATCH 1

j 01045 091986 0/0 CP MG/L TRON, TOTAL (AS FE) 01/DD NO D8SCHARGE l

i 4

Page 20 1

I I

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Managemerd - Descharge Monitoring Report (DMR) r KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flow 107000 GPD ND = none detected Descharg 1B2 A Mon Loc-1 BLOWDOWN FR HEAT & COOL Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

01051 091986 0/0 CP MG/L LEAD TOTAL (AS PB) 01/DD NO DISCHARGE 01067 091986 0/0 CP MG/L NICKEL, TOTAL (AS NI) 01/DD NO DISCHARGE 00556 091986 0/0 G

MG/L OlL & GREASE FREON EXTR 01/DD NO DISCHARGE 00400 091986 0/0 G

SU PH 01/DD NO DISCHARGE 1

i 00530 091986 0/0 CP MG/L SOLIDS. TOTAL SUSPENDED 01/DD NO DISCHARGE 01092 091986 0/0 CP MG/L ZINC, TOTAL (AS ZN) 01/DD NO DISCHARGE KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flom 30000 GPD ND = none detected Discharg 1B2 B Mon Loc: 1 STEAM ELECTRIC POWER PLNT Sample Weeks:

Code Statt s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

00310 091986 0/0 CP MG/L BOD 5 DAY (20 DEG C) 01/DD NO DISCHARGE 01027 091986 0/0 CP MG/L CADMlUM, TOTAL (AS CD) 01/DD NO DISCHARGE 00335 091986 0/0 CP MG/L CHEMICAL OXYGEN DEMAND 01/DD NO DISCHARGE 01/DD NO DISCHARGE 01034 091986 0/0 CP MG/L CHROMlUM, TOTAL (AS CR) 77666 120192 0/1 CP MG/L CITRIC ACID WHOLE WATER 01/DD NO DISCHARGE 01042 091986 0/0 CP MG/L COPPER, TOTAL (AS CU) 01/DD NO DISCHARGE 78151 120192 0/1 CP MG/L EDTA 01/DD NO DISCHARGE Page 21

STATE OF CONNECTICUT ~ DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Managemerd - Discharge Monitoring Report (DMR)

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flovc 30000 GPD ND = none deteded Descharg 182 B Mon Loc: 1 STEAM ELECTRIC POWER PLNT Sample Weeks Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

00164 120192 Oli I

GPB FLOW, GALLONS / BATCH 01/DD NODISCHARGE 77006 120192 0/1 CP MG/L FORMIC ACID WHOLE WATER 01/DD NO DISCHARGE 00139 091986 0/0 CP MG/L HYDROGEN PEROX1DE 01/DD NO DISCHARGE 01045 091986 0/0 CP MG/L IRON, TOTAL (AS FE) 01/DD NO DISCHARGE 01051 091986 0/0 CP MG/L LEAD, TOTAL (AS PB) 01/DD NO DISCHARGE 01067 091986 0/0 CP MG/L NICKEL, TOTAL (AS NI) 01/DD NO DISCHARGE 00556 120192 C/1 G

MG/L OIL & GREASE FREON EXTR 01/DD NO DISCHARGE 77081 120192 0/1 CP MG/L OXALIC ACID 01/DD NO DISCHARGE 00400 091986 0/0 RC SU PH 01/DD NO DISCHARGE 00530 091986 0/0 CP MG/L SOLIDS, TOTAL SUSPENDED 01/DD NO DISCHARGE l

01092 091986 0/0 CP MG/L ZINC, TOTAL (AS ZN) 01/DD NO DISCHARGE l

l l

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 i

l Average Flovc 144000 GPD ND = none detected Discharg 1C1 A Mon Loc 1 BLOWDOWN FR HEAT & COOL Sample Weeks:

l Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

i 00164 120192 Ol1 I

GPB FLOW, GALLONS / BATCH 13089 01/DD NF NF 13089 NF l

81313 120192 0/1 G

MG/L HYDRAZINE 94 01/DD NF NF 94 NF Page 22

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Discharge Monitoring Report (DMR)

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Fkm 30000 GPD ND = none detected Discharg 182 B Mon Loc-1 STEAM ELECTRIC POWER PLNT Sample Weeks:

Code Start s!m Typ Orst Parameter Minimu Average Maximu Freq 1

2 3

4 5

00164 120192 0/1 1

GPB FLOW, GALLONS / BATCH 01/DD NO DISCHARGE 77006 120192 0/1 CP MG/L FORMIC ACID WHOLE WATER 01/DD NO DISCHARGE 00139 091986 0/0 CP MG/L HYDROGEN PEROXIDE 01/DO NO DISCHARGE 01045 091986 0/0 CP MG/L IRON, TOTAL (AS FE) 01/DO NO D;SCHARGE 01051 091986 0/0 CP MG/L LEAD. TOTAL (AS PB) 01/DD NO DISCHARGE 01067 091986 0/0 CP MG/L NICKEL, TOTAL (AS NI) 01/DD NO DISCHARGE 00556 120192 Oli G

MG/L OIL & GREASE FREON EXTR 01/DD NO DISCHARGE i

77081 120192 0/1 CP MG/L OXAllC ACID 01/DD NO DISCHARGE 00400 091980 0/0 RC SU PH 01/DD NO DISCHARGE 00530 091986 0/0 CP MG/L SOLIDS TOTAL SUSPENDED 01/DD NO DISCHARGE 01092 091986 0/0 CP MG/L ZINC, TOTAL (AS ZN) 01/DD NO DISCHARGE KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Fkw.144000 GPD ND = none detected Discharg 1C1 A Mon Loc-1 BLOWDOWN FR HEAT & COOL Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu Average Maximu Freq 1

2 3

4 5

00164 120192 Oli i

GPB FLOW, GALLONS / BATCH 13089 01/D0 NF NF 13089 NF 81313 120192 0/1 G

MG/L HYDRAZINE 94 01/DD NF NF 94 NF 4

Page 22

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water ^^ -;=-.,...;- Dacharge Monitoring Report (DMR)

^

MEY: CT0003263

' lssue: 121492 Expwe: 12/14/97 Sample Month Fetruary 1997 Average Flour. 40000 GPD NO = none detected Discharg 1C6 A Mon Loc-1 WATER PRODUCTION WASTEWTR Sample Weeks l

Code Start s/m Typ Unit Parameter Mmimu Average Mammu Freq 1

2 3

4 5

00310 091986 0/0 CP MG/L BOD 5 DAY (20 DEG C) 01/DD NO DISCHARGE.

01/DD NO DISCHARGE 0102.

091986 0/0 ' CP MG/L CADMlUM, TOTAL (AS CD) 00335 091906 0/0 CP MG/L CHEMICAL OXYGEN DEMAND 01/DD NO DISCHARGE

'01034 091986 0/0 CP MG/L CHROMlUM, TOTAL (AS CR) 01/DD NO DISCHARGE 77666 120192 0/1 ' CP MG/L CITRIC ACID WHOLE WATER 01/DD NO DISCHARGE t

01042 091986 0/0 CP MG/L COPPER, TOTAL (AS CU) 01/DD NO DISCHARGE i

78151 120192 0/1 CP MG/L EDTA 01/DD '

NO DISCHARGE l

~

~

01/DD NO DISCHARGE I

00164 120192 0/1 1

GPS FLOW, GALLONS / BATCH i

77006 120192 0/1 CP MG/L FORMIC ACID WHOLE WATER

~

~

01/DD NO DISCHARGE I

00139 091986 0/0 CP MG/L HYDROGEN PEROXIDE 01/DD NO DISCHARGE l

~

~

01045 091986 0/0 CP MG/L IRON, TOTAL (AS FE) 01/DD NO DISCHARGE

[

01051 091986 0/0 CP MG/L LEAD, TOTAL (AS PS) 01/DD NO DISCHARGE i

01067 091986 0/0 CP MG/L NICKEL TOTAL (AS NI) 01/DD NO DISCHARGE 00556 120192 0/1 G

MG/L Ott & GREASE FREON EXTR 01/DD NO DISCHARGE 77061 120192 0/1 CP MG/L OXALIC ACID 01/DD NO DISCHARGE 00400 091986 0/0 RC SU PH 01/DD NO DISCHARGE 00530 091986 0/0 CP MG/L SOLIDS, TOTAL SUSPENDED

~

~

01/DD NO DISCHARGE 01092 091986 0/0 CP MG/L ZlNC, TOTAL (AS ZN) 01/DD NO DISCHARGE f

Page 23 1

i

@ TATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Descharge Monitoring Report (DMR)

KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month February 1997 Average Flovc 72000 GPD NO = none detected Descharg 1C6 B Mon Loc-1 BLOWDOWN FR HEAT & COOL Sample Weeks:

Code Start s/m Typ Unit Parameter Minimu AveraQe Maximu Freq 1

2 3

4 5

00056 120192 0/1 T

GPD FLOW RATE AVERAGE DAILY 11630 01/07 9710 11280 11630 10540

~

~

Weekly max. see Table 5 81313 091986 0/0 CP MG/L HYDRAZINE 74 01/07 74 72 73 72 Weekly max. see Table 5 00011 120192 0/1 G DEG TEMPERATURE DEG FAHR 195 01/07 195 190 195 195

~

~

Weekly max. see Table 5 COMMENTS:

Page 24 i

- ~,.

+..

PERMIT: CT0003263 DIST: 12 TOWN: 152 LOC:003 FACluTY: MILLSTONE NUCLEAR POWER STA.

MAILING NAME:

NORTHEAST NUCLEAR ENERGY CO.

ADDRESS: RTE 156 ADDRESS:

P. O. BOX 270 CITY, STATE, Z1P: WATERFORD, CT 06385 CITY, STATE, ZIP:

HARTFORD, CT 06101 l

CONTACT:

MR. PAUL JACOBSON CONTACT:

MR. PAUL JACOBSON PHONE (860) 447-1791 Ext. 2335 PHONE:

(860) 447-1791 Ext. 2335 If there are any changes or corrections with your facility information, please cross out incorrect information and replace with correct information.

THIS DMR CONSISTS OF 25 PAGES FOR THE REPORTING PERIOD February 1997 STATEMENT OF ACKNOWLEDGEMENT I certify under penalty of law that this document is identical in format and content to the preprinted Discharge Monitoring Report which I received from the Department of Environmental Protection on:

12/22/95 I certify under penalty of law that this document and all attachments were prepared under my diredion or supervision in accordance with a system designed to assure that qualified personnel property gather and evaluate the information submitted. Based on my enquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the

[

information submitted is, to the best of my knowledge and belief, true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and impnsonment for knowing violations.

L Authorized Official:

S. E. Scace

Title:

Director - Nuclear Engineering Programs

ococe, Date:

.3/ 9Y Signature:

- Page 25

TABLE 1. Pega 1 CILLStouE ST* TION / ALL UNITS MONTNLY WTER euALITY DATA SLBeuRY / DISCMARGE SERIAL NLDOER 001 DATA PERIOD = 1 FEB 97/0000 - 28 FEB 97/2345 DATA AceUISITION INTERVAL = MIIRJTES 00-15 0F EACM NOUR DAY PN RANGE FLOW RANGE MAX MIN AVG SDEV MAX MIN AVG SDEV MAX ML MIN NL AVG ML SO NL IRC NL MAX MIN AVG TEM YEM TEW TEM DEL T DEL T DEL T DEL T 1

8.1-8.0 674 66 428 39.6 38.4 38.7 0.3 2.6 1.0 1.5 0.5 501.3 36.7 286.9 149.9 -168.6 2

8.1-8.0 66 66 66 39.6 38.7 39.1 0.3 1.7 1.0 1.3 0.2 56.0 33.5 43.8 5.6 10.3 3

8.0- 7.9 66 66 66 39.5 39.1 39.3 0.1 1.6 1.0 1.4 0.2 53.7 33.2 45.5 5.9 8.5 6

8.1-7.9 66 66 66 40.0 39.1 39.7 0.3 2.2 1.2 2.0 0.3 73.7 39.2 67.1 8.7

-32.7 5

8.1-8.0 66 66 66 40.4 38.9 39.9 0.4 2.3 1.3 1.9 0.3 75.2 41.9 64.1 9.0

-26.6 6

8.1-8.0 337 66 154 40.2 39.2 39.7 0.3 2.4 1.3 1.8 0.3 404.2 44.3 140.3 121.2 153.8 7

8.1-8.0 370 66 92 40.1 38.3 39.4 0.5 2.8 1.3 2.0 0.5 380.0 41.4 91.4 88.8 305.3 8

8.1-8.1 522 370 402 39.6 38.4 38.8 0.3 2.1 1.0 1.4 0.2 382.8 185.3 274.4 58.8 134.5 0

8.1-8.0 370 66 85 39.2 37.8 38.5 0.4 1.9 0.9 1.3 0.3 231.3 29.6 55.4 42.3

-99.8 to 8.1-8.0 66 66 66 39.0 38.2 38.5 0.3 2.4 1.2 1.8 0.3 78.4 38.3 57.8 11.2

-10.2 11 8.1-8.0 66 66 66 39.3 38.3 38.8 0.4 2.3 1.1 1.7 0.3 74.6 35.7 57.2 10.5

-31.3 12 8.1-8.0 66 66 66 39.4 38.5 39.0 0.2 2.4 1.7 2.1 0.2 78.4 54.5 70.5 6.4 11.8 13 8.1-8.1 332 66 240 39.0 38.0 38.3 0.3 2.2 1.1 1.7 0.3 355.0 42.4 203.2 115.2 247.6 14 8.1-8.0 66 66 66 38.8 37.9 38.3 0.3 2.3 1.3 1.8 0.3 77.2 43.0 58.3 10.8 11.4 15 8.1-e.1 784 66 433 38.9 38.1 38.3 0.2 2.3 0.9 1.4 0.4 575.2 73.9 287.8 125.8 315.0 16 8.1-8.1 328 66 88 39.0 37.8 38.3 0.4 2.2 1.1 1.5 0.3 231.1 35.9 63.5 50.2 -176.1 17 8.2-8.1 66 51 52 39.3 38.0 38.6 0.4 2.8 1.1 2.0 0.5 71.8 28.6 52.9 13.6

-23.9 18 8.2-8.1 51 39 44 39.8 38.3 17.1 0.6 3.1 2.1 2.6 0.3 68.7 46.8 56.5 6.1

-13.0 19 8.2-8.1 39 39 39 41.0 38.9 39.8 0.7 2.8 1.6 2.2 0.3 55.0 30.7 43.2 6.4

-15.5 20 8.2-8.1 301 176 265 40.8 39.2 39.5 0.4 2.6 0.7 1.4 0.4 253.3 103.2 182.1 49.9 93.4 21 8.2-8.1 301 291 301 30.3 38.8 39.1 0.1 1.5 0.6 1.2 0.2 219.7

.L4 174.8 34.4 51.9 22 8.2-8.1 757 301 567 40.4 39.2 39.7 0.4 1.5 0.2 0.9 0.3 551.6 on.S 246.1 140.2 206.8 23 8.2 8.1 301 301 301 39.9 39.4 39.6 0.1 2.1 0.8 1.2 0.4 311.7 121.4 182.6 56.0 85.3 24 8.2-8.1 301 39 214 39.6 38.9 39.4 0.2 1.5 0.5 i.i 0.3 232.7 10.5 134.0 88.7. -133.0 25 8.2-8.1 54 39 51 39.5 38.0 39.0 0.4 2.6 1.1 1.7 0.5 71.3 20.7 45.2 14.3 19.4 26 8.2-8.1 54 54 54 40.2 38.8 39.5 0.4 3.2 1.7 2.3 0.4 86.4 47.1 62.2 10.5 13.0 27 8.2-8.1 59 54 54 40.9 39.7 40.3 0.3 2.6 1.8 2.2 0.2 69.2 49.6 60.6 5.1

-11.5 28 8.2-8.1 54 54 54 40.9 40.4 40.6 0.1 2.3 1.3 2.0 0.3 63.5 33.9 54.5 9.3 13.0 MON 8.2-7.9 784 39 160 41.0 37.8 39.2 0.7 3.2 0.2 1.7 0.5 575.2 10.5 113.8 102.9 315.0 t

PN RANGE = LOE ST AND NIGNEST PM AT GUARRY CUT (PM UNITS)

FLOW RAME = LOWEST AND NIGNEST FLOW FROM QUARRY CUT (10**3 GAL / MIN)

MAX TEMP = MAXINUM TEMPERATURE AT DISCNARGE AREA (DEG F)

Cl3 TEW = MIN 18EM TEMPERATURE AT DISCNARGE AREA (DEG F)

AVG TEMP = AVERAGE TEMPERATURE AT DISCMARGE AREA (DEG F) l SDEV TEMP = STANDARO DEVIATION OF TEMPERATURE AT DISCNARGE AREA (DEG F)

MAX DEL T = MAXIMUM TEMPERATURE INCREASE BETWEN INTAE AND QUARRY CUT (DEG F)

CI3 DEL T = MINIMUM TEMPERATURE INCREASE BETWEEN INTAE AND QUARRY OJT (DEG F)

AVG DEL T = AVERAGE TEMPERATURE INCREASE BETWEEN INTAE AND QUARRY CUT (DEG F)

SDEV DEL T = STANDARD DEVIATION OF TEMPERATURE INCREASE BETWEEN INTAE AND QUARRY CUT (DEG F)

MAX NL = hAXIfRM NEAT LOAD OF DISCNARGE WTER (10**6 BTU /NR)

CIJ NL = MINiptJM NEAT LOAD OF DISCNARGE WATER (10**6 BTU /NR)

AVG ML = AVERAGE NEAT LOAO OF DISCMARGE W TER (10**6 BTU /NR) 50 NL e STANDARD DEVIATION OF NEAT LOAD OF DISCMARGE WATER (10**6 BTU /NR)

MRC NL = MAXIMUM RATE OF CHANGE OF NEAT LOAD (NL FOR QUARTER NOUR T MINUS NL FOR QUARTER NCANt T-1/ QUARTER NOUR) (10**6 BTU /NR**2)

        • MEANS MISSING UR INSUFFICIENT DATA (LESS TMAN 12 NRS/ DAY OF VALID NOURLY DATA! LESS TNAN 360 NRS/ MONTH OF VALID NOURLY DATA) l l

=

TABLE 1. Pcg2 2 CILLST ONE STATION / ALL UNITS MONTRY nd4TER eUALITY DATA St#84tRY / DISCMARGE SERIAL WL5eER 001 EHCEPTION REPORT FOR 9NutIIRM TEMPERATURE DIFFERENCE FRON INTAKE AREA TO GUARRY CUT GREATER TRAN 32 DEG F WOME EXCEPfl0N REPORT FOR 94ANIIRM GUNtRY TEMPERATURE GREATER inAN 105 DEG F h0NE EXCEPTION REPORT FOR PM AT GUMtRY QJT LESS TMAN 6.0 OR GREATER TMAN 9.0 PM UNITS N(kT i

t i

4

,~ -

~...-.--s-

' TABLE 1. Pcg2 3 MILLSTONE ST* TION / UNIT 1 MONTRY WATER SUALITY DATA SupetARY / DISCMARGE SERIAL NUMBER 0014 e

DATA PERIOD = 1 PER 97/0000 28 FE8 97/2345 DATA ACeutSITION INTERVAL = MIIRITES 00-15 0F EACM NOUR DAY PN RANE FLOW RANGE CIRC Pt2P Malt MIN AVG SOEV max MIN AVG - Sw(V max at MIN wt AVG ML SD ML MRC ML MAX MIN AVG MAN MIN TEpP TEPP TEMP TEMP DEL T DEL'T DEL T DEL T 1

7.8-7.7 12 12 12 0

0 40.7 39.8 40.2 0.3 3.4 2.7 3.0 0.2 20.2 15.9 17.9 1.0 1.8 2

7.8-7.7 12 12 12 0

0 41.1 40.5 40.8 9.2 3.4 2.5 3.0 0.3 20.5 14.9 18.0 1.5

-2.4 3

7.8-T.8 12 12 12 0

0 41.0 39.9 40.5 0.5 3.1 2.0 2.5 0.5 18.4 11.9 15.3 2.9

-5.5 6

7.8-7.8 12 12 12 0

0 42.1 40.6 41.5 0.6 4.4 3.0 3.8 0.5 26.6 17.9 22.9

- 3.3 5.3 5

7.8-7.7 12 12 12 0

0 41.2 40.5 40.9 0.2 3.1 2.5 2.9 0.1 18.5 15.2 17.6 0.8-

-2.1 6

7.8-7.7 20 12 12 0

0 42.0 40.7 40.9 0.3 4.4 2.7 3.0 0.4 31.3 15.9 18.7~

3.4 -

-13.7 7

7.> T.7 12 12 12 0

0 41.4 40.2 40.6 0.3 3.7 3.0 3.2 0.2 22.3 17.9 19.2 1.0

-3.1 8

7.8-7.8 12 12 12 0

0 40.7 40.1 40.5 0.1 3.2 2.9 3.0 0.1 18.9 17.2 18.2 0.5 1.4 9

7.9-7.7 12 12 12 0

0 40.4 39.9 40.1 0.2 3.2 2.8 3.0 0.1 19.1 16.5 18.0 0.8

-1.4 10 7.9-7.8 12 12 12 0

0 40.3 39.4 39.9 0.3 3.6 2.9 3.1 0.2 21.3 17.3 18.7 1.1 1.5 11 7.8-7.7 12 12 12 0

0 40.3 39.7 40.0 0.1 3.4 2.8 3.0 0.2 20.7 16.6 17.7 1.1 1.6 12 7.8-T.7 12 12 12 0

0 40.1 39.7 39.9 0.1 3.2 2.9 3.0 0.1 19.5 17.3 18.3 0.6 0.7 i

13 7.9-7.8 15 12 12 0

0 40.0 39.4 39.7 0.2 3.3 2.7 3.1 0.2 24.3 16.0 18.8 1.5

-5.1 14 -

7.8-7.7 12 12 12 0

0 39.8 39.4 39.5 0.1 3.2 2.8 3.0 0.1 19.1 16.8 18.1 0.4 1.0 15 7.8-7.8 12 12 12 0

0 40.3 39.5 39.9 0.2 3.1 2.8 3.0 0.1 18.5 16.8 17.9 0.4

-1.6 13 7.9-7.7 12 12 12 0

0 41.2 39.6 40.0 0.4 4.0 2.7 3.2 0.3 24.1 16.2 19.0 1.6 7.9 17 7.9-7.8 12 12 12 0

0 39.9 39.3 39.6 0.2 3.4 2.9 3.1 0.1 20.1 17.3 18.4 0.7

-1.4 18 7.0- 7.8 12 12 12 0

0 40.2 39.0 39.5 0.4 3.2 2.8 3.0 0.1 19.2 16.9 18.0 0.5

-1.2 17 8.0- 7.8 12 12 12 0

0 41.0 39.9 40.4 0.4 2.9 2.4 2.8 0.2 17.6 14.3 16.5 1.0

-1.6 20 7.9-7.8 12 12 12 0

0 41.4 40.5 40.9 0.2 3.1 2.5 2.8 0.2 18.8 14.7 17.1 1.1 2.0 21 7.9-7.8 12 1

11 0

0 41.1 40.3 40.7 0.2 3.1 2.3 2.8 0.2 18.3 1.7 16.0 3.3

-16.1 22 7.9-T.7 12 12 12 0

0 42.3 40.9 41.5 0.4 3.0 2.3 2.7 0.2 18.1 13.9 16.4 1.1

-2.9 23 8.0- T.8 12 12 12 0

0 41.7 40.7 41.3 0.3 3.5 2.6 2.9 0.2 21.0 15.7 17.4 1.2 2.8 24 8.0- T.8 12 12 12 0

0 41.6 40.9 41.2 0.3 3.2 2.7 2.9 0.2 19.4 16.0 17.5 1.1 2.5 25 7.9-7.8 12 12 12 0

0 41.0 39.9 40.2 0.3 3.5 2.5 3.0 0.3 21.0 15.0 17.9 1.6 2.7 26 8.0- 7.8 12 12 12 0

0 40.7 39.6 40.2 0.4 3.3 2.5 3.0 0.2 19.9 15.2 17.7 1.4

-2.8 27 8.0- 7.8 17 12 12 0

0 41.7 40.3 40.8 0.3 3.1 2.6 2.8 0.1 24.2 15.5 17.2 1.7 7.7 28 8.0- 7.8 12 12 12 0

0 41.8 40.9 41.%

0.3 2.8 2.4 2.7 0.1 17.0 14.7 16.0 0.6 1.8 MON 8.0- 7.7 20 1

12 0

0 42.3 39.0 40.4 0.7 4.4 2.0 3.0 0.3 31.3 1.7 17.8 1.9

-16.1 PN RANGE = LOE ST AND MIGHEST PM AT DISCMARGE STRUCTURE (PN 1261T5)

FLOW RANGE = LOWEST AND MIGNEST FLOW FROM DISCNARGE STRUCTURE (10**3 GAL / MIN)

CIRC PUIW' = LOWEST AND NIGNEST NUMBER OF CIRC PUNPS OPERATING tuut TEMP = suutiMUM TEMPERATURE AT DISCIIARGE STRUCTURE (DEG F)

CID TE9F = MINIMUM TEMPERATURE AT DISCMARGE STRUCTURE (DEG F) i AVG TE9F = AVERAGE TEMPERATURE AT DISCMARGE STRUCTURE (DEG F)

SDEV TEMP = STAsWARD DEVIATION OF TEMPERATURE AT DISCNARGE STRUCTURE (DEC F) 9Wut DEL T = 9WutlMUM TEMPERATURE INCREASE BETWEEN INTAKE AND DISCMARGE (DEG F)

Cl3 DEL T = MINifRJM TEMPERATURE INCREASE SETWEEN INTAKE AND DISCllARGE (DEG F)

AVG DEL T = AVERAGE TEMPERATURE INCREASE BETWEEN INTAKE AND DISCMARGE (DEC F)

SDEV DEL T = STANDARD DEVIATION OF TEMPERATURE INCREASE BETWEEN INTAKE AND DISCMARGE (DEG F)

+

IWUt K e IWutI8R24 IIEAT LOAD OF DISCNARGE WATER (10**6 BTU /MR)

Kl3 K e MINIMUM MEAT LOAD OF DISCMARGE WATER (10**6 STU/NR)

AVG K = AVERAGE MEAT LOAD OF DISCNARGE WATER (10**6 BTU / int)

SD E = STANDARD DEVI4il0N OF NEAT LOAD OF DISCMARGE WATER (10**6 BTU /MR)

MRC E e IWutIMUM RATE OF CMANGE OF NEAT LOAD (IIL FOR GUARTER MOUR T MINUS ML FOR GUARTER MOUR T-1/GUARTER MOUR) (10**6 STU/ int **2)

        • MEA 8tS MISSING OR INSUFFICIENT DATA (LESS TMAN 12 MAS /DAT OF VALID MOURLY DATA; LESS TMAN 360 INts/MONTM OF VALIO MOURLY DATA)

TABLE 1. Paga 4

  • WILLST

' WE STITIM / 18117 1 MouTHLY WRTER SUALITY DATA SUIsthRY / DISC #ARE SERIAL E88ER 001A

+

EECEPTI N REPORT FOR MAxleRM TEMPERATURE D!FFERENCE FROM UNIT 1 INTAKE TO UNIT 1 DISCMARGE GREATER YnAn 32 DEG F NOME ENGPTION REPORT FOR 8thMIIRm DISCHARGE TE8PERATURE AT Ulsti 1 DISCMARGE GREATER TMAN 105 DEG F L

EXCEPTton REPORT FOR PM AT UNIT 1 DISCNARGE LESS TMAN 6.0 OR GREATER TMAst 9,0 PM LElITS IIONE b

____._-,___._____.________m____.__..___.._.._

TABLE 1. Pcg2 5 l

C1LLSTONE STATION / UNIT 2 IGNTMLY WATER QUALITY DATA StsetARY / DISCMARGE SERIAL WLMBER 0018 DATA *ERIOD = 1 FE8 97/0000 - 28 FEB 97/2345 DATA ACQUISITION INTERVAL = MINUTES 00-15 or EACM NOUR DAT PN RANGE FLOW RANGE CIRC PtBIP MAX MIN AVG SDEV MAX MIN AVG SOEV MAX K MIN ML AVG NL SD ML MRC ML MAX MIN AVG MAX MIN TEW TEM TEw TEMP DEL T DEL T DEL T DEL T 1

8.0- 8.0 24 24 24 0

0 39.5 38.8 39.1 0.2 1.8 0.8 1.2 0.3 21.9 9.3 14.3 3.1

-6.2 2

8.0- 8.0 24 24 24 0

0 40.0 38.7 39.3 0.4 1.6 0.6 1.0 0.3 19.1 6.8 12.0 3.7

-5.0 3

8.0- 7.8 24 24 24 0

0 40.0 39.6 39.8 0.1 2.0 1.1 1.6 0.4 23,8 13.7 18.8 4.4 9.5 4

8.0- 8.0 24 24 24 0

0 39.8 39.2 39.5 0.2 1.7 1.0 1.2 0.2 20.8 11.7 15.0 2.5

-6.4 5

8.0- 7.9 24 24 24 0

0 39.8 39.1 39.4 0.2 1.4 0.9 1.1 0.1 16.4 10.4 12.6 1.2 5.1 6

8.0- 7.9 286 24 112 2

0 40.8 38.0 39.1 0.7 2.7 0.0 0.7 0.7 34.1 0.0 9.3 9.8

-34.1 7

8.1-8.0 24 24 24 0

0 41.1 39.0 39.6 0.5 2.9 0.9 1.5 0.5 34.5 10.9 17.6 6.2

-12.2 8

8.0- 8.0 24 24 24 0

0 39.3 38.7 39.1 0.1 1.2 0.9 1.1 0.1 14.7 10.3 12.8 1.2 2.5 9

8.1-8.0 24 2'

24 0

0 39.1 38.4 38.9 0.2 1.4 0.8 1.1 0.1 16.7 10.1 13.6 1.7 3.8 10 8.1-8.0 24 24 24 0

0 39.1 37.7 38.6 0.4 1.8 0.5 1.2 0.3 21.5 6.2 14.2 3.1 5.4 11 8.1-8.0 24 24 24 0

0 39.1 38.4 38.8 0.2 1.3 1.0 1.1 0.1 15.7 11.5 13.3 1.1 2.9 12 8.1-7.9 24 24 24 0

0 38.9 38.5 38.7 0.1 1.5 0.9 1.2 0.1 17.5 11.1 14.1 1.6

-4.0 13 8.1-8.0 286 24 198 2

0 38.7 36.5 37.5 0.7 1.4 0.0 0.3 0.6 16.7 0.0 4.3 6.6

-16.7 14 8.1-7.9 24 24 24 0

0 38.5 37.9 38.2 0.1 1.3 0.8 1.1 0.1 15.2 10.0 13.1 1.4

-4.4 15 8.1-8.0 286 24 150 2

0 38.5 37.1 37.8 0.5 1.1 0.0 0.5 0.5 13.4 0.0 6.1 6.3

-12.1 16 8.1-7.9 286 24 46 2

0 38.9 36.9 38.4 0.5 1.7 0.0 0.9 0.5 20.0 0.0 10.6 5.5 9.8 17 8.1-8.0 24 24 24 0

0 38.8 37.9 38.4 0.2 1.5 0.9 1.2 0.2 18.3 10.7 14.3 1.9

-4.6 18 8.1-8.0 24 12 17 0

0 39.1 37.4 38.2 0.5 1.5 0.9 1.2 0.2 16.3 5.3 10.3 4.2

-8.2 19 8.1-8.0 12 12 12 0

0 40.6 38.9 39.5 0.5 2.0 0.8 1.4 0.3 12.1 4.7 8.3 1.6 3.2 20 8.1-8.0 274 149 238 2

1 38.7 37.7 38.2 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 21 8.1-8.0 274 274 274 2

1 38.6 37.3 38.0 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 22 8.1-7.9 274 2 73 274 2

1 39.9 37.8 38.8 0.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 23 8.2-8.0 274 2 74 274 2

2 39.2 38.1 38.6 0.3 0.1 0.0 0.0 0.0 9.1 0.0 0.6 2.0

-9.1 24 8.2-8.0 274 12 187 2

0 40.2 37.9 38.8 0.8 3.2 0.0 1.0 1.4 64.3 0.0 8.3 14.4 64.3 25 8.1-8.0 12 12 12 0

0 39.9 39.0 39.4 0.3 3.8 0.5 2.4 1.2 23.0 3.3 14.5 7.1

-9.2 26 8.2-8.1 12 12 12 0

0 39.8 38.4 39.2 0.4 1.7 0.6 1.0 0.4 10.0 3.6 6.0 2.1 2.9 27 8.1-8.0 12 12 12 0

0 41.0 39.1 40.0 0.5 1.4 0.6 0.9 0.2 8.4 3.6 5.4 1.2

-2.6 28 8.1-7.8 12 12 12 0

0 42.6 39.7 41.2 1.2 2.4 0.3 1.6 0.8 14.5 2.0 9.5 5.0 2.0 MON 8.2-7.8 286 12 77 2

0 42.6 36.5 38.9 0.8 3.8 0.0 1.0 0.7 64.3 0.0 9.8 7.0 64.3 PN RANGE = LOWEST AND MIGNEST PM AT DISCMARGE STRUCTURE (PM UNITS)

FLOW RANCE = LOWEST AND MIGNEST FLOW FROM DISCHARGE STRUCTURE (10**3 GAL / MIN) 2 C Pur = LOWEST AND MIGNEST NUMBER OF CIRC PUMPS OPERATING hAX TL.Y = MAXIMUM TEMPERATURE AT DISCMARGE STRUCTURE (DEG F)

Cl3 TE M = MINIMIDI itMPERATURE AT DISCMARGE STRUCTURE (DEG F)

AVG TEM = AVERAGE iEMPERATURE AT DISCMARGE STRUCTURE (DEG F)

SDEV TEMP = STANDARD DEVI ATION OF TEMPERATURE AT DISCHARGE STRUCTURE (DEG F)

MAX DEL T = MAXINLM TEMPERATURE INCREASE BETWEEN INTAKE AND DISCMARGE (DEG F)

Cl3 DEL T = MINIMUM TEMPERATURE INCREASE SETWEEN INTAKE AND DISCMARGE (DEG F)

AVG DEL T = AVERAGE TEMPERATURE INCREASE BETWEEN INTAKE AND DISCHARGE (DEG F)

SDEV DEL T = STANDARD DEVIAfl0N OF TEMPERATURE INCREASE BETWEEN INTAKE AND DISCHARGE (DEG F)

MAX K e MAtlMUM MEAT LOAD OF DISCHARGE WATER (10"6 BTU /MR)

CIJ Kt a MINIMUM MEAT LOAD OF DISCHARGE WATER (10**6 BTU /NR)

AVG ML e AVERAGE MEAT LOAO OF DISCHARGE WATER (10**6 STU/NR) 50 R e STANDARD DEVIATION OF MEAT LOAD OF DISCMARGE WATER (10"6 8TU/NR)

MRC R e MAXIMUM RATE OF CHANGE OF MEAT LOAD (ML FOR QUARTER HOUR T MINUS ML FOR QUARTER MOUR T-1/ QUARTER MOUR) (10**6 BTU /MR**2)

        • MEANS MISSING OR INSUFFICIENT DATA (LESS THAN 12 MRS/ DAY OF VALID MGJRLY DATA; LESS THAN 360 MRS/MONTM OF VALID MOURLY DATA)

TABLE 1. Pagh 6 auE STITION / URIT 2 NOWTIILY W4TER euRLITY DATA SupeuWtY / DISOIARGE SERIAL NLeeER 0010 ENGPTION REPORT FOR MANINUM TEMPERATURE DIFFERENCE FROM UNIT 2 IuTAKE TO UNIT 2 DistnARGE GREATER inAN 32 DEC F NOME EXCEPTION REPORT FOR MANIpRSI DISCHAlt9E TEMPERATURE AT UNIT 2 DISCMARGE GREATER inAll 105 DEG F -

Nauf ENCEPTIou REMIti FOR PW AT UNIT 2 DISCnARGE LESS inAu 6.0 OR GREATER T!tAs 9.0 PN U11175 IIONE L

f i

. a-.

.m-v--

w-r.------

-w, w.,

sm w-o.r

~~ w

.TA;LE 1. Pagm 7 CILLSTONE ST* TION / LAIIT 3

=

MONTRY WTER SUALITY DATA SUIseARY / DISCMARE SERIAL Wisq8ER 001C

+

+

DATA PERIS = 1 FEB 97/9000 - 28 FEB 97/2345 DATA ACEUISITIDW INTERVAL = MINUTES 00-15 or EACM MOUR DAY PW RANGE FLOW RAN8E Cl#C PUMP MAM MIN AVG SDEV MAM MIN AVG SDEV MM NL MIN R AVG E SD E MRC R MAK MIN AVG MAM MIN TE9F TEMP TEMP TEMP DEL T DEL T DEL T DEL T 1-8.1-8.0 638 30 347 4

0 39.9 38.1 38.7 0.5 2.1 0.3 0.7 0.5 210.4 5.6 108.8 67.9 -118.4 2

8.1-8.0 30 30 30 0

0 40.2 39.7 40.0 0.2 1.9 1.4 1.6 0.1 29.2 20.8 24.5 2.2 5.1 3

8.1-8.0 30 30 30 0

0 43.0 40.0 40.9 1.1 5.0 1.6 2.7 1.3 75.6 23.5 40.9 19.6 35.4 4

8.1-8.0 30 30 30 0

0 40.1 39.7 39.9 0.1 2.0 1.5 1.7 0.1 30.4 22.6 25.4 2.0 5.7 5

8.1-8.0 30 30 30 0

0 40.2 39.9 40.0 0.1 2.1 1.5 1.7 0.1 31.7 22.1 25.0 2.2 7.7 6

8.1-8.0 30 30 30 0

0 40.6 40.0 40.4 0.2 2.3 1.4 1.9 0.3 35.2 20.4 29.1 3.9 13.6 7

8.1-8.0 334 30 55 2

0 40.5 38.7 40.1 0.5 2.7 0.5 2.0 0.5 79.4 25.0 35.9 13.8 52.3 8

.8.1 8.0 486 334 366 3

2 38.7 38.5 38.6 0.1 1.0 0.4 0.6 0.1 158.9 65.3 103.9 24.1 63.8 9

8.1-8.0 334 30 49 2

0 39.8 38.4 39.5 0.4 2.3 0.7 1.7 0.5 114.7 11.9 32.8 19.6

-53.4 to 8.1-8.0 30 30 30 0

0 39.7 38.5 39.2 0.4 2.0 1.4 1.8 0.2 30.6 20.3 26.8 3.1

-7.0 11 8.1-8.0 30 30 30 0

0 39.5 38.8 39.2 0.2 1.9 1.2 1.6 0.2 28.8 18.6 23.8 2.4 5.5 12 8.1-8.0 30 30 30 0

0 39.5 38.8 39.3 0.2 2.1 1.5 1.8 0.2 31.9 22.0 26.7 2.5 7.2 13 8.1-8.0 30 30 30 0

0 39.3 38.6 38.9 0.2 2.0 1.2 1.6 0.3 30.2 17.3 24.3 3.8

-7.0 to 8.1 8.0 30 30 30 0

0 38.8 38.6 38.7 0.1 1.8 1.3 1.5 0.1 27.2 19.2 23.2 2.2 6.1 15 8.1-8.0 486 30 271 3

0 39.3 38.0 38.4 0.4 1.8 0.2 0.9 0.5 147.2 8.4 83.8 44.1 -138.8 16 8.1-8.0 30 30 30 0

0 40.0 39.3 39.7 0.2 2.7 1.8 2.2 0.3 41.1 26.7 33.0 3.9 10.0 17 8.1-8.0 30 15 16 0

0 39.8 38.8 39.6 0.3 2.9 1.5 2.3 0.4 33.0 11.1 18.5 4.1

-11.7 18 8.1-8.0 15 15 15 0

0 39.8 38.7 39.1 0.5 2.5 1.6 2.1 0.2 18.6 12.3 15.8 1.6

-3.9 17 8.2-8.0 15 15 15 0

0 41.5 39.7 40.7 0.6 3.3 1.8 2.6 0.4 24.4 13.6 19.3 3.1

-7.0 20 8.1-7.8 15 15 15 0

0 41.8 41.1 41.3 0.2 3.2 2.1 2.7 0.3 23.9 15.8 20.5 2.2

-4.8 21 8.1-8.0 15 15 15 0

0 41.2 40.9 41.1 0.1 3.4 1.7 2.6 0.4 25.4 13.1 19.3 3.1 3.2 22 8.2-8.0 471 15 281 3

0 41.5 38.8 40.2 1.0 2.6 0.0 1.0 1.1 555.1 0.0 52.3 112.5 536.3 23 8.2-8.0 15 15 15 0

0 41.6 40.6 41.2 0.3 3.1 1.7 2.4 0.5 23.0 12.5 17.8 3.6

-3.8 24 8.2-8.0 15 15 15 0

0 41.4 40.6 40.9 0.3 4.5 1.6 2.9 1.0 33.8 11.8 21.5 7.5 12.3 25 8.2-8.1 30 15 27 0

0 40.8 39.3 39.7 0.5 4.5 0.7 2.7 1.3 62.6 10.5 35.1 15.9 28.7 26 8.2-8.1 30 30 30 0

0 39.8 38.6 39.2 0.5 1.3 0.4 1.0 0.2 19.9 5.3 14.7 3.5

-11.1 27 8.2-8.1 30 30 30 0

0 40.6 39.8 40.2 0.3 1.6 0.4 1.1 0.3 24.2 5.6 16.4 5.0

-8.8 28 8.2-8.1 30 30 30 0

0 40.9 40.3 40.5 0.2 1.4 0.6 0.9 0.2 20.3 9.2 14.1 2.5

-6.2 MON 8.2-7.8 638 15 69 4

0 43.0 38.0 39.8 0.9 5.0 0.0 1.8 0.8 555.1 0.0 33.0 36.3 536.3 PM RANGE = LOWEST AND MIGNEST PM AT DISCMARGE STRUCTURE (PM UNITS)

FLOW RANGE = LOWEST Ase NIGNEST FLOW FROM DISCMARGE STRUCTURE (10**3 GAL / MIN)

CIRC PUMP = LOWEST AND MIGNEST NtseER OF CIRC PUMPS OPERATING MAX TEMP = MAXIMUM TEMPERATURE AT DISCHARGE STRUCTURE (DEG F)

EI3 TEMP = MINIMUM TE WERATURE AT DISCHARGE STRUCTURE (DEG F)

AVG TEMP = AVERAGE TEMPERATURE AT DISCMARGE STRUCTURE (DEG F)

SDEV TEMP = STANDARD DEVI ATION OF TEMPERATURE AT DISCHARGE STRUCTURE (DEG F)

MAX DEL T = MAXIpRm TEMPERATURE INCREASE BETWEEN INTAKE AND DISCMARGE (DEG F)

Cl3 DEL T = MINIMUM TEpFERATURE INCREASE BETWEEN INTAKE AND DISCMARGE (DEG F)

AVG DEL T = AVERAGE TEMPERATURE INCREASE BETWEEN INTAKE AND DISCHARGE (DEG F)

SDEV DEL T = STANDARD DEVIATION OF TEMPERATURE INCREASE BETWEEN INTAKE AND DISCHARGE (DEG F)

MAN R = MAXIMUM MEAT LOAD OF DISCMARGE WATER (10**6 BTU /NR)

Cl3 K = MINIMUM MEAT LOAD OF DISCHARGE WATER (10**6 STU/M )

AVG ML = AVERAGE MEAT LOAD OF DISCMARGE WATER (10**6 STU/NR)

SD R e STANDARD DEVIATION OF MEAT LOAD OF DISCMARGE WATER (10**6 STU/HR)

MRC E = MMIIRm RATF OF CHANGE OF MEAT LOAD (R FOR QUARTER MOUR T MINUS E FOR QUARTER MOUR T-1/ QUARTER MOUR) (10**6 STU/NR**2)

        • MEANS MISSING OR INSUFFICIENT DATA (LESS TMAN 12 MRS/ DAY OF VALID MOURLY DATA; LESS THAN 360 MRS/MONTM OF VALID MOURLY DATA)

~ - -

TABLE 1. Peg 2 8

' M ntsf DE STATION / UNIT 3 MONTNLY WTER suALITY DATA SuputARY / SISCMARGE SERIAL NUISER 001C ENEPTION REPORT FOR INutistm TUPERATUK DIFFERENCE FRON UNIT 3 INTAKE TO UNIT 3 DISCMARGE GREATER inAN 24 DEG F NOME ENCEPTION REPORT FOR puutInts DISCnAMIE TE9FERATURE AT UNIT 3 DISCMARGE GREATER TMAN 98 DEG F NONE ENCEPTION REPORT FOR PM AT UNIT 3 DISCNARGE LESS TMAN 6.0 OR GREATER TMAN 9.0 PM UNITS NOME

5 l

  • f TABLE 2 MILLSTONE STATION i

_DMR-Attached Reporting Month: February 1997

'The following reporting will be done to accurately ' reflect the-permit 1)

Loadings and concentrations within permit limits will not be reported as an exceedance where the DMR forms lists incorrect j

values.

2)

Parameter blanks not required by the permit will be marked N/A.

j 3)

Parameter reporting not shown on the DMR forms, but required by the pemit will be listed in this attachment.

l DSN 001 I

Flow is permitted as maximum 2,73 8,000,000 gpd. However, this flow is an average flow value which was defined in the previous permit. The renewed permit changed flow nomenclature to maximum and as such flow will exceed the limit in most i

months.

This problem is being addressed through permit modification, and is not being reported as an exceedance.

1 DSN 001A Flow is permitted as maximum 604,800,000 gpd.

However, this flow is an average flow value which was defined in the previous permit. The renewed permit changed flow nomenclature to maximum and as such flow will exceed the limit in most i

months.

This problem is being addressed through permit modification, and is not being reported as an exceedance.

DSN 001A-4 The following parameters are not included on the DMR forms:

Boric acid:

Code 9 mg/l (weekly grab, 574 mg/l max)

Boric acid:

Code 9 kg/ day (weekly grab, 7.6 kg/ day max)

DSN 001B Flow is permitted as maximum 820,000,000 gpd.

However, this flow is an average flow value which was defined in the i

previous permit. The renewed permit changed flow nomenclature to maximum and as such flow will exceed the limit in most months.

This problem is being addressed through permit j

modification, and is not being reported as an exceedance.

)

j DSN 001B-1 The following parameters are not included on the DMR forms:

i Ethanolamine:

No Discharoe mg/l (weekly grab, 10.0 mg/l max)

{

i

4 hilloton3 DMR Tcblo 2 Page 2 l

DSN 001B-1(a)

The following parameters are not included on the DMR forms:

Ethanolamine:

No Discharoe mg/l (daily grab, 5.0 mg/l max)

DSN 001B-2 The DMR form has an average TSS limit of 30.0 mg/1.

This is not in the permit.

DSN 001B-2(b)

The following parameters are not included on the DMR forms:

Nitric acid:

No Distharme mg/l (daily comp.)

Permanganate:

No Discharas mg/l (daily comp.)

DSN 001B-3 The DMR form has an average TSS limit of 15.0 mg/1, and a maximum TSS limit of 30.0 mg/1. This is inconsistant with the permit which has only a maximum TSS limit of 22.5 mg/1.

DSN 001B-6 The following parameters are not included on the DMR forms:

Ethanolamine:

0.8 kg/ batch (weekly grab, 230 kg max)

DSN 001B-7 The DMR form has a maximum chlorine loading limit of 5.46 kg/ day.

This is inconsistant with the permit which does not have a chlorine loading limit.

DSN 001B-8 The following parameters are not included on the DMR forms:

Ethanolamine:

<2.6 mg/l (daily grab, 230 mg/l max)

DSN 001C Flow is permitted as maximum 1,313,200,000 gpd. However, this flow is an average flow value which was defined in the previous permit. The renewed permit changed flow nomenclature to maximum and as such flow will exceed the limit in most months.

This problem is being addressed through permit modification, and is not being reported as an exceedance.

A reporting block for Pimenhales oromelas toxicity testing is j

on the DMR form but is not required by the permit.

MillstonD DMR Table 2 Page 3 DSN 001C-1 The following parameters are not included on the DMR forms:

Ethanolamine:

No Discharae mg/l (15.0 mg/l max) l t

DSN 001C-1(ql The following parameters are not included on the DMR forms:

Ethanolamine:

0.192 mg/l (5.0 mg/l max)

DSN 001C-6 The following parameters are not included on the DMR forms:

Ethanolamine:

11.3 kg/ batch (300.0 kg/ batch max)

DSN 001C-6(a)

The following parameters are not included on the DMR forms:

Nitric acid:

No Dischar.gg_ mg/l (daily comp.)

Permanganate:

No Discharae mg/l (daily comp.)

DSN 001C-8 The following parameters are not included on the DMR forms:

Ethanolamine:

No Discharce mg/l (3.0 mg/l max)

DSN 006 Two sets of forms have been supplied for this discharge.

Toxicity testing for Pimechales oromelas is on the DMR form, but is not required on by the permit.

l l

- /

I TABLE 3 February 1997 Millstone DSN 006 additional TRC data i

i Week 1 Week 2 Week 3 Week 4 Week 5 l

<0.02 0.12 0.07

<0.02 0.02

<0.02

<0.02 0.02 0.02 0.02

<0.02

<0.02 0.02 0.02

<0.02

<0.02 1

<0.02

<0.02

<0.02 0.02

<0.02 0.05

<0.02 0.03 t

l

?

)

4 a

f

)

i I

1 I

i

[<

R TABLE 4 February 1997 Milstone DSN 001C-5 additional Free Available Chlorine data (rna/L)

Week 1 Week 2 Week 3 Week 4 Week 5 0.15 0.15 0.15 0.17 0.17 0.17

<0.02 0.16 0.17 0.17 0.16 0.17 0.19 0.17 0.16 0.10 0.15 0.14 0.14 0.13 0.16 0.14 0.13 0.11 0.14 0.10 0.13 0.12 0.13 0.16 0.10 0.14 DSN 001B-9 Discharaes. Deicina Pit and RBCCW Sumo fjgg Hydrazine. mall Temo.F 1920

<0.35 54 8000

<0.35 68 7952

<0.35 57 10256

<0.35 59 4452

<0.35 58 2324

<0.35 56 644

<0.35 69 i

J d

J 4

I Table 5 February 1997 additional discharae data DSN 001C-6b Temperature Flow Totalizer Hydrazine. mall 190 221260 68 180 222700 46 185 224220 60 180 225620 40 190 227230 68 180 228900 74 180 230670 32 195 232410 18 180 233930 68 185 235570 64 185 237190 72 190 238410 40 190 240500 72 180 242050 34 180 243690 58 195 245150 36 195 246780 73 190 248390 69 180 249980 29 180 252460 60 180 253910 39 160 255320 58 190 256920 39 195 258590 60 195 259930 62 195 261660 47 180 263010 72 195 264560 41 l

i