- 05000286/LER-1984-004-01, :on 840209,reactor Trip Actuated on Steam Flow/Feed Flow Mismatch for Steam Generator 32.Caused by Loss of Both Heater Drain Pumps.Associated Instrument Air Lines Blown Down Removing Condensation + (ML20081C141)
- ML20081C143 + (ML20081C143)
- ML20081C147 + (ML20081C147)
- ML20081C148 + (ML20081C148)
- ML20081C150 + (ML20081C150)
- ML20081C151 + (ML20081C151)
- ML20081C153 + (ML20081C153)
- ML20081C155 + (ML20081C155)
- ML20081C157 + (ML20081C157)
- ML20081C158 + (ML20081C158)
- AECM-84-0135, Special Rept 84-007/0:on 840131 & 0210,bolts Securing Div 1 Standby Diesel Generator Left Bank Turbocharger Failed During 100 H Test Runs.No Noticeable Effect on Engine Performance Noted.Ler 83-107 Will Be Updated + (ML20081C159)
- ML20081C161 + (ML20081C161)
- ML20081C164 + (ML20081C164)
- ML20081C171 + (ML20081C171)
- ML20081C173 + (ML20081C173)
- ML20081C175 + (ML20081C175)
- ML20081C177 + (ML20081C177)
- W3P84-0431, Discusses Activities & Commitments to Be Completed Prior to Fuel Load.Listed Open Items Will Be Completed Prior to 840430 + (ML20081C187)
- W3P84-0601, Advises That Listed Procedures & Tech Specs Reviewed,Per Generic Ltr 83-28 Re post-maint Testing of Reactor Trip Sys Components.Check of Vendor & Engineering Recommendations Concluded Test Guidance Incorporated Into Procedures + (ML20081C189)
- ML20081C191 + (ML20081C191)
- ML20081C194 + (ML20081C194)
- ML20081C197 + (ML20081C197)
- ML20081C200 + (ML20081C200)
- ML20081C202 + (ML20081C202)
- 05000370/LER-1984-002, :on 840115,both Nd Trains Declared Inoperable When Breakers for Valves 2ND-1B & 2NB-2A Closed.Caused by Personnel Error.Procedures Revised & Personnel Counseled + (ML20081C206)
- ML20081C207 + (ML20081C207)
- ML20081C209 + (ML20081C209)
- ML20081C210 + (ML20081C210)
- ML20081C214 + (ML20081C214)
- ML20081C220 + (ML20081C220)
- ML20081C221 + (ML20081C221)
- ML20081C222 + (ML20081C222)
- ML20081C223 + (ML20081C223)
- ML20081C228 + (ML20081C228)
- W3P84-0602, Requests That NUREG-0737,Item II.E.4.2 Re Containment Pressure Setpoint Be Closed in Next Sser.Facility Will Employ 17.1 Psia Setpoint,Per Tech Specs + (ML20081C237)
- ML20081C239 + (ML20081C239)
- ML20081C242 + (ML20081C242)
- ML20081C245 + (ML20081C245)
- ML20081C256 + (ML20081C256)
- ML20081C264 + (ML20081C264)
- ML20081C271 + (ML20081C271)
- ML20081C274 + (ML20081C274)
- ML20081C276 + (ML20081C276)
- ML20081C278 + (ML20081C278)
- ML20081C279 + (ML20081C279)
- ML20081C283 + (ML20081C283)
- ML20081C286 + (ML20081C286)
- ML20081C288 + (ML20081C288)
- ML20081C289 + (ML20081C289)