- ML20038B653 + (ML20038B653)
- ML20038B654 + (ML20038B654)
- ML20038B657 + (ML20038B657)
- ML20038B659 + (ML20038B659)
- ML20038B662 + (ML20038B662)
- ML20038B663 + (ML20038B663)
- ML20038B665 + (ML20038B665)
- IR 05000440/1981014 + (ML20038B667)
- ML20038B669 + (ML20038B669)
- ML20038B671 + (ML20038B671)
- ML20038B672 + (ML20038B672)
- IR 05000454/1981011 + (ML20038B673)
- ML20038B675 + (ML20038B675)
- ML20038B677 + (ML20038B677)
- ML20038B678 + (ML20038B678)
- ML20038B680 + (ML20038B680)
- ML20038B681 + (ML20038B681)
- ML20038B682 + (ML20038B682)
- ML20038B685 + (ML20038B685)
- ML20038B687 + (ML20038B687)
- ML20038B689 + (ML20038B689)
- 05000206/LER-1981-027, Forwards LER 81-027/01T-0.Detailed Event Analysis Submitted + (ML20038B695)
- ML20038B700 + (ML20038B700)
- ML20038B701 + (ML20038B701)
- ML20038B704 + (ML20038B704)
- 05000206/LER-1981-027-01, /01T-0:on 811109,routine Weekly Boron Analysis of Refueling Water Storage Tank Indicated Less than Tech Spec Limit.Caused by Nonrepresentative Boron Concentration Samples Misleading Operators Re Actual Concentration + (ML20038B706)
- ML20038B707 + (ML20038B707)
- ML20038B708 + (ML20038B708)
- ML20038B709 + (ML20038B709)
- ML20038B711 + (ML20038B711)
- IR 05000245/1981014 + (ML20038B715)
- ML20038B716 + (ML20038B716)
- ML20038B717 + (ML20038B717)
- ML20038B718 + (ML20038B718)
- ML20038B721 + (ML20038B721)
- ML20038B725 + (ML20038B725)
- ML20038B726 + (ML20038B726)
- 2CAN118109, Advises That After Further Discussion,Original 811013 Submittal Transmitting Sept 1981 Monthly Operating Rept, Determined to Be Correct.Outage Should Be Designated as Forced + (ML20038B727)
- ML20038B728 + (ML20038B728)
- 05000366/LER-1981-110, Forwards LER 81-110/03L-0 + (ML20038B729)
- ML20038B732 + (ML20038B732)
- ML20038B733 + (ML20038B733)
- 05000237/LER-1981-017, Forwards LER 81-017/03L-0 + (ML20038B734)
- ML20038B736 + (ML20038B736)
- 05000366/LER-1981-110-03, /03L-0:on 811107,RHR Loop a Removed from Shutdown Cooling Mode to Standby Configuration.While Swapping from Shutdown Cooling to Torus Suction,Torus Suction Valve 2E11- FOO4C Failed.Caused by Valve Limit Switch Failure + (ML20038B737)
- ML20038B738 + (ML20038B738)
- 05000321/LER-1981-121, Forwards LER 81-121/03L-0 + (ML20038B739)
- ML20038B743 + (ML20038B743)
- 05000237/LER-1981-017-03, /03L-0:on 810408,QA Audit Discovered That Temp of Cells Adjacent to Pilot Cell Had Not Been Taken,Per Tech Specs.Caused by Inadvertent Oversight Due to Inadequate Procedures.Change Will Be Implemented by June 1981 + (ML20038B745)
- 05000321/LER-1981-121-03, /03L-0:on 811104,IRM 1C51-K601E Failed W/Irm C Inoperable for Maint.Caused by Cold Solder Joint on J1 Signal Input to IRM Drawer Electronics.Connection Repaired + (ML20038B747)
- 05000366/LER-1981-108, Forwards LER 81-108/03L-0 + (ML20038B749)