- AECM-81-431, Final Deficiency Rept Re Safety Relief Valve Control Sys, Originally Reported on 771007.Design of Sys Which Controls Safety Relief Valve Actuation Modified.Mod Presented to NRC by GE on 800208.Description of Design Submitted 810902 + (ML20032B362)
- ML20032B363 + (ML20032B363)
- ML20032B364 + (ML20032B364)
- 05000369/LER-1981-018-03, /03L-0:on 810219,annunciator Alarm Indicated Loss of Sample Flow on Radiation Monitor 1-EMF-33.Monitor Vacuum Pump Internally Damaged Due to Water Inside Pump.Pump Vanes & Bearings Replaced & Water Removed + (ML20032B365)
- ML20032B366 + (ML20032B366)
- IR 05000324/1981019 + (ML20032B367)
- ML20032B368 + (ML20032B368)
- ML20032B369 + (ML20032B369)
- ML20032B370 + (ML20032B370)
- IR 05000289/1981024 + (ML20032B371)
- ML20032B372 + (ML20032B372)
- 05000369/LER-1981-023, Forwards LER 81-023/03L-0 + (ML20032B373)
- ML20032B375 + (ML20032B375)
- 05000369/LER-1981-023-03, /03L-0:on 810227-0313,various Firestops & Fire Doors Inoperable for Periods Exceeding 1-h.Caused by Const in & Through Areas Normally Closed Off.Fire Watches & Patrol Established as Required + (ML20032B376)
- ML20032B377 + (ML20032B377)
- ML20032B378 + (ML20032B378)
- 05000369/LER-1981-024, Forwards LER 81-024/01T-0 + (ML20032B380)
- ML20032B382 + (ML20032B382)
- ML20032B383 + (ML20032B383)
- 05000369/LER-1981-024-01, /01T-0:on 810316,Unit 1 Wedge Plates Discovered to Be Smaller than Required Size.Cause Not Stated.Calculations Reviewed to Determine Acceptance.Corrective Action Deemed Necessary.Bar Along Length of Washer Plate Added + (ML20032B384)
- ML20032B385 + (ML20032B385)
- 05000271/LER-1981-025, Forwards LER 81-025/03L-0 + (ML20032B386)
- A01460, Submits Schedule for Emergency Preparedness Exercises Per NRC .Dates Acceptable by State of CT & Fema. Requests Info Re NRC Personnel Attending,Social Security Numbers,Security Clearance & Vital Areas to Be Accessed + (ML20032B388)
- 05000271/LER-1981-025-03, /03L-0:on 810928,containment Isolation Valve LRW-95 Failed to Close During Testing.Caused by Mechanical Binding of Valve Stem & Packing.Valve Stem Lubricated + (ML20032B389)
- ML20032B390 + (ML20032B390)
- ML20032B392 + (ML20032B392)
- ML20032B394 + (ML20032B394)
- ML20032B395 + (ML20032B395)
- ML20032B396 + (ML20032B396)
- ML20032B397 + (ML20032B397)
- ML20032B398 + (ML20032B398)
- ML20032B399 + (ML20032B399)
- ML20032B400 + (ML20032B400)
- ML20032B401 + (ML20032B401)
- ML20032B403 + (ML20032B403)
- ML20032B404 + (ML20032B404)
- ML20032B405 + (ML20032B405)
- ML20032B407 + (ML20032B407)
- IR 05000293/1981013 + (ML20032B413)
- ML20032B416 + (ML20032B416)
- ML20032B419 + (ML20032B419)
- ML20032B420 + (ML20032B420)
- ML20032B422 + (ML20032B422)
- ML20032B423 + (ML20032B423)
- ML20032B425 + (ML20032B425)
- IR 05000348/1981021 + (ML20032B426)
- ML20032B427 + (ML20032B427)
- IR 05000327/1981034 + (ML20032B429)
- ML20032B430 + (ML20032B430)
- IR 05000259/1981030 + (ML20032B432)
- IR 05000370/1981017 + (ML20032B433)